WorldWideScience

Sample records for blood vessel detection

  1. Detection of blood vessels on coronary cineangiograms

    International Nuclear Information System (INIS)

    Yanagihara, Yosio; Sugahara, Tetsuo; Uyama, Chikao

    1988-01-01

    To determine the most suitable filter for measuring blood vessel width on a coronary cineagiogram, several sizes of vessel phantoms were taken under different energies and contrast substance densities on cine film and the vessel widths were calculated by using several edge detection filters. Among the filters, the entropy and Gaussian filters were found to be twice as accurate as the derivative filters. The entropy filter was applied to one frame of a coronary angiogram, and the detected vessel edges were as accurate as the determined by a radiologist. This filter can be applied to coronary cineangiograms, including stenosed sites. (author)

  2. Detection of Blood Vessels in Retinal Fundus Images

    Directory of Open Access Journals (Sweden)

    Faraz Oloumi

    2014-07-01

    Full Text Available Detection of blood vessels in retinal fundus images is an important initial step in the development of systems for computer-aided diagnosis of pathologies of the eye. In this study, we perform multifeature analysis for the detection of blood vessels in retinal fundus images. The vessel detection techniques implemented include multiscale vesselness measures, Gabor filters, line operators, and matched filters. The selection of an appropriate threshold is crucial for accurate detection of retinal blood vessels. We evaluate an adaptive threshold selection method along with several others for this purpose. We also propose a postprocessing technique for removal of false-positive pixels around the optic nerve head. Values of the area under the receiver operating haracteristic curve of up to $0.961$ were obtained using the $20$ test images of the DRIVE database.

  3. Improvement of retinal blood vessel detection by spur removal and Gaussian matched filtering compensation

    Science.gov (United States)

    Xiao, Di; Vignarajan, Janardhan; An, Dong; Tay-Kearney, Mei-Ling; Kanagasingam, Yogi

    2016-03-01

    Retinal photography is a non-invasive and well-accepted clinical diagnosis of ocular diseases. Qualitative and quantitative assessment of retinal images is crucial in ocular diseases related clinical application. In this paper, we proposed approaches for improving the quality of blood vessel detection based on our initial blood vessel detection methods. A blood vessel spur pruning method has been developed for removing the blood vessel spurs both on vessel medial lines and binary vessel masks, which are caused by artifacts and side-effect of Gaussian matched vessel enhancement. A Gaussian matched filtering compensation method has been developed for removing incorrect vessel branches in the areas of low illumination. The proposed approaches were applied and tested on the color fundus images from one publicly available database and our diabetic retinopathy screening dataset. A preliminary result has demonstrated the robustness and good performance of the proposed approaches and their potential application for improving retinal blood vessel detection.

  4. Remission spectrometry for blood vessel detection during stereotactic biopsy of brain tumors.

    Science.gov (United States)

    Markwardt, Niklas A; Stepp, Herbert; Franz, Gerhard; Sroka, Ronald; Goetz, Marcus; Zelenkov, Petr; Rühm, Adrian

    2017-08-01

    Stereotactic biopsy is used to enable diagnostic confirmation of brain tumors and treatment planning. Despite being a well-established technique, it is related to significant morbidity and mortality rates mostly caused by hemorrhages due to blood vessel ruptures. This paper presents a method of vessel detection during stereotactic biopsy that can be easily implemented by integrating two side-view fibers into a conventional side-cutting biopsy needle. Tissue within the needle window is illuminated through the first fiber; the second fiber detects the remitted light. By taking the ratio of the intensities at two wavelengths with strongly differing hemoglobin absorption, blood vessels can be recognized immediately before biopsy sampling. Via ray tracing simulations and phantom experiments, the dependency of the remission ratio R = I 578 /I 650 on various parameters (blood oxygenation, fiber-to-vessel and inter-fiber distance, vessel diameter and orientation) was investigated for a bare-fiber probe. Up to 800-1200 µm away from the probe, a vessel can be recognized by a considerable reduction of the remission ratio from the background level. The technique was also successfully tested with a real biopsy needle probe on both optical phantoms and ex-vivo porcine brain tissue, thus showing potential to improve the safety of stereotactic biopsy. Dual-wavelength remission measurement for the detection of blood vessels during stereotactic biopsy. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Detection of Blood Vessels in Color Fundus Images using a Local Radon Transform

    Directory of Open Access Journals (Sweden)

    Reza Pourreza

    2010-09-01

    Full Text Available Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable available sub-vessel. To verify the detected sub-vessel, the maximum is compared with a predefined threshold. The verified sub-vessels are reconstructed using the Radon transform information. All detected and reconstructed sub-vessels are finally combined to make the final vessel tree. Results: The algorithm’s performance was evaluated numerically by applying it to 40 images of DRIVE database, a standard retinal image database. The vessels were extracted manually by two physicians. This database was used to test and compare the available and proposed algorithms for vessel detection in color fundus images. By comparing the output of the algorithm with the manual results, the two parameters TPR and FPR were calculated for each image and the average of TPRs and FPRs were used to plot the ROC curve. Discussion and Conclusion: Comparison of the ROC curve of this algorithm with other algorithms demonstrated the high achieved accuracy. Beside the high accuracy, the Radon transform which is integral-based makes the algorithm robust against noise.

  6. An Automatic Cognitive Graph-Based Segmentation for Detection of Blood Vessels in Retinal Images

    Directory of Open Access Journals (Sweden)

    Rasha Al Shehhi

    2016-01-01

    Full Text Available This paper presents a hierarchical graph-based segmentation for blood vessel detection in digital retinal images. This segmentation employs some of perceptual Gestalt principles: similarity, closure, continuity, and proximity to merge segments into coherent connected vessel-like patterns. The integration of Gestalt principles is based on object-based features (e.g., color and black top-hat (BTH morphology and context and graph-analysis algorithms (e.g., Dijkstra path. The segmentation framework consists of two main steps: preprocessing and multiscale graph-based segmentation. Preprocessing is to enhance lighting condition, due to low illumination contrast, and to construct necessary features to enhance vessel structure due to sensitivity of vessel patterns to multiscale/multiorientation structure. Graph-based segmentation is to decrease computational processing required for region of interest into most semantic objects. The segmentation was evaluated on three publicly available datasets. Experimental results show that preprocessing stage achieves better results compared to state-of-the-art enhancement methods. The performance of the proposed graph-based segmentation is found to be consistent and comparable to other existing methods, with improved capability of detecting small/thin vessels.

  7. Optics based signal processing methods for intraoperative blood vessel detection and quantification in real time (Conference Presentation)

    Science.gov (United States)

    Chaturvedi, Amal; Shukair, Shetha A.; Le Rolland, Paul; Vijayvergia, Mayank; Subramanian, Hariharan; Gunn, Jonathan W.

    2016-03-01

    Minimally invasive operations require surgeons to make difficult cuts to blood vessels and other tissues with impaired tactile and visual feedback. This leads to inadvertent cuts to blood vessels hidden beneath tissue, causing serious health risks to patients and a non-reimbursable financial burden to hospitals. Intraoperative imaging technologies have been developed, but these expensive systems can be cumbersome and provide only a high-level view of blood vessel networks. In this research, we propose a lean reflectance-based system, comprised of a dual wavelength LED, photodiode, and novel signal processing algorithms for rapid vessel characterization. Since this system takes advantage of the inherent pulsatile light absorption characteristics of blood vessels, no contrast agent is required for its ability to detect the presence of a blood vessel buried deep inside any tissue type (up to a cm) in real time. Once a vessel is detected, the system is able to estimate the distance of the vessel from the probe and the diameter size of the vessel (with a resolution of ~2mm), as well as delineate the type of tissue surrounding the vessel. The system is low-cost, functions in real-time, and could be mounted on already existing surgical tools, such as Kittner dissectors or laparoscopic suction irrigation cannulae. Having been successfully validated ex vivo, this technology will next be tested in a live porcine study and eventually in clinical trials.

  8. Apparatus and method for examining a blood vessel of interest using radiation detected outside the body

    International Nuclear Information System (INIS)

    Shaw, R.F.

    1982-01-01

    Stenotic atherosclerotic lesions of the coronary arteries are detected by injecting a number of particulate signal sources such as positron-emitting particles (e.g. gallium 68) into the blood of a subject to determine the velocity of blood flow through the coronary vessels. The particles are tracked in three dimensions whenever they appear in the region of the heart by means of high-resolution high-speed gamma detectors that surround the chest. These recordings of particle position as a function of time are analyzed, and the velocity of blood as it flows through the coronary artery is measured by timing the transit of the particle. From the accumulated data of multiple particle transits through the coronary circulation, a three-dimensional representation of the lumen of the coronary arterial system is constructed

  9. OCT imaging detection of brain blood vessels in mouse, based on semiconducting polymer nanoparticles.

    Science.gov (United States)

    Yang, Shaozhuang; Chen, Haobin; Liu, Liwei; Chen, Bingling; Yang, Zhigang; Wu, Changfeng; Hu, Siyi; Lin, Huiyun; Li, Buhong; Qu, Junle

    2017-11-20

    Optical Coherence Tomography (OCT) is a valuable technology that has been used to obtain microstructure images of tissue, and has several advantages, though its applications are limited in high-scattering tissues. Therefore, semiconducting polymer nanoparticles (SPNs) that possess strong absorption characteristics are applied to decrease light scattering in tissues and used as exogenous contrast agents for enhancing the contrast of OCT imaging detection. In this paper, we prepared two kinds of SPNs, termed PIDT-TBZ SPNs and PBDT-TBZ SPNs, as the contrast agents for OCT detection to enhance the signal. Firstly, we proved that they were good contrast agents for OCT imaging in agar-TiO 2 . After that, the contrast effects of these two SPNs were quantitatively analyzed, and then cerebral blood vessels were monitored by a home-made SD-OCT system. Finally, we created OCT images in vitro and in vivo with these two probes and performed quantitative analysis using the images. The results indicated that these SPNs created a clear contrast enhancement of small vessels in the OCT imaging process, which provides a basis for the application of SPNs as contrast agents for bioimaging studies.

  10. Segmentation of retinal blood vessels using artificial neural networks for early detection of diabetic retinopathy

    Science.gov (United States)

    Mann, Kulwinder S.; Kaur, Sukhpreet

    2017-06-01

    There are various eye diseases in the patients suffering from the diabetes which includes Diabetic Retinopathy, Glaucoma, Hypertension etc. These all are the most common sight threatening eye diseases due to the changes in the blood vessel structure. The proposed method using supervised methods concluded that the segmentation of the retinal blood vessels can be performed accurately using neural networks training. It uses features which include Gray level features; Moment Invariant based features, Gabor filtering, Intensity feature, Vesselness feature for feature vector computation. Then the feature vector is calculated using only the prominent features.

  11. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomenology of radiation-induced changes in blood vessels are systematized and authors' experience is generalized. Modern concepts about processes leading to vessel structure injury after irradiation is critically analyzed. Special attention is paid to reparation and compensation of X-ray vessel injury, consideration of which is not yet sufficiently elucidated in literature

  12. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  13. Blood vessels, circulation and blood pressure.

    Science.gov (United States)

    Hendry, Charles; Farley, Alistair; McLafferty, Ella

    This article, which forms part of the life sciences series, describes the vessels of the body's blood and lymphatic circulatory systems. Blood pressure and its regulatory systems are examined. The causes and management of hypertension are also explored. It is important that nurses and other healthcare professionals understand the various mechanisms involved in the regulation of blood pressure to prevent high blood pressure or ameliorate its damaging consequences.

  14. Photoacoustic determination of blood vessel diameter

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Klaessens, John H.G.M.; Hondebrink, Erwin; Hopman, Jeroen C.W.; de Mul, F.F.M.; Steenbergen, Wiendelt; Thijssen, Johan M.; van Leeuwen, Ton

    2004-01-01

    A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-topeak time (τ pp) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual vessel

  15. ICG-assisted blood vessel detection during stereotactic neurosurgery: simulation study on excitation power limitations due to thermal effects in human brain tissue.

    Science.gov (United States)

    Rühm, Adrian; Göbel, Werner; Sroka, Ronald; Stepp, Herbert

    2014-09-01

    Intraoperative blood vessel detection based on intraluminal indocyanin-green (ICG) would allow to minimize the risk of blood vessel perforation during stereotactic brain tumor biopsy. For a fiber-based approach compatible with clinical conditions, the maximum tolerable excitation light power was derived from simulations of the thermal heat load on the tissue. Using the simulation software LITCIT, the temperature distribution in human brain tissue was calculated as a function of time for realistic single-fiber probes (0.72mm active diameter, numerical aperture 0.35, optional focusing to 0.29mm diameter) and for the optimum ICG excitation wavelength of 785nm. The asymptotic maximum temperature in the simulated tissue region was derived for different radiant fluxes at the distal fiber end. Worst case values were assumed for all other parameters. In addition to homogeneous (normal and tumor) brain tissue with homogeneous blood perfusion, models with localized extra blood vessels incorporated ahead of the distal fiber end were investigated. If one demands that destruction of normal brain tissue must be excluded by limiting the tissue heating to 42°C, then the radiant flux at the distal fiber end must be limited to 33mW with and 43mW without focusing. When considering extra blood vessels of 0.1mm diameter incorporated into homogeneously perfused brain tissue, the tolerable radiant flux is reduced to 22mW with and 32mW without focusing. The threshold value according to legal laser safety regulations for human skin tissue is 28.5mW. For the envisaged modality of blood vessel detection, light power limits for an application-relevant fiber configuration were determined and found to be roughly consistent with present legal regulations for skin tissue. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Automated measurement of retinal blood vessel tortuosity

    Science.gov (United States)

    Joshi, Vinayak; Reinhardt, Joseph M.; Abramoff, Michael D.

    2010-03-01

    Abnormalities in the vascular pattern of the retina are associated with retinal diseases and are also risk factors for systemic diseases, especially cardiovascular diseases. The three-dimensional retinal vascular pattern is mostly formed congenitally, but is then modified over life, in response to aging, vessel wall dystrophies and long term changes in blood flow and pressure. A characteristic of the vascular pattern that is appreciated by clinicians is vascular tortuosity, i.e. how curved or kinked a blood vessel, either vein or artery, appears along its course. We developed a new quantitative metric for vascular tortuosity, based on the vessel's angle of curvature, length of the curved vessel over its chord length (arc to chord ratio), number of curvature sign changes, and combined these into a unidimensional metric, Tortuosity Index (TI). In comparison to other published methods this method can estimate appropriate TI for vessels with constant curvature sign and vessels with equal arc to chord ratios, as well. We applied this method to a dataset of 15 digital fundus images of 8 patients with Facioscapulohumeral muscular dystrophy (FSHD), and to the other publically available dataset of 60 fundus images of normal cases and patients with hypertensive retinopathy, of which the arterial and venous tortuosities have also been graded by masked experts (ophthalmologists). The method produced exactly the same rank-ordered list of vessel tortuosity (TI) values as obtained by averaging the tortuosity grading given by 3 ophthalmologists for FSHD dataset and a list of TI values with high ranking correlation with the ophthalmologist's grading for the other dataset. Our results show that TI has potential to detect and evaluate abnormal retinal vascular structure in early diagnosis and prognosis of retinopathies.

  17. Combination probe for optically assisted ultrasonic velocity-change imaging aimed at detecting unstable blood vessel plaque

    Science.gov (United States)

    Tanigawa, Shohei; Mano, Kazune; Wada, Kenji; Matsunaka, Toshiyuki; Horinaka, Hiromichi

    2016-04-01

    Blood vessel plaque with a large lipid core is at risk of becoming thrombus and is likely to induce acute heart disease. To prevent this, it is necessary to determine not only the plaque's size but also its chemical composition. We, therefore, made the prototype of a combination probe to diagnose carotid artery plaque. It is used to differentiate propagation characteristics between light spectra and ultrasonic images. By propagating light and ultrasound along a common direction, it is possible to effectively warm the diagnosis domain. Moreover, the probe is thought to be compact and be easy to use for diagnosing human carotid artery plaque. We applied the combination probe to a carotid artery phantom with a lipid area and obtained an image of the ultrasonic velocity change in the fatty area.

  18. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  19. Subconjunctival Hemorrhage (Broken Blood Vessel in Eye)

    Science.gov (United States)

    Subconjunctival hemorrhage (broken blood vessel in eye) Overview A subconjunctival hemorrhage (sub-kun-JUNK-tih-vul HEM-uh-ruj) ... may not even realize you have a subconjunctival hemorrhage until you look in the mirror and notice ...

  20. Three-dimensional photoacoustic imaging of blood vessels in tissue

    NARCIS (Netherlands)

    Hoelen, C.G.A.; de Mul, F.F.M.; Pongers, R.; Dekker, A.

    1998-01-01

    We applied photoacoustics as a tissue tomography technique for the detection of blood concentrations, e.g., angiogenesis around tumors. We imaged blood vessels in highly scattering samples, using 532-nm light, to depths of ,1 cm. The samples were real tissue (chicken breast) or 10% dilutions of

  1. Trends in Tissue Engineering for Blood Vessels

    Science.gov (United States)

    Nemeno-Guanzon, Judee Grace; Lee, Soojung; Berg, Johan Robert; Jo, Yong Hwa; Yeo, Jee Eun; Nam, Bo Mi; Koh, Yong-Gon; Lee, Jeong Ik

    2012-01-01

    Over the years, cardiovascular diseases continue to increase and affect not only human health but also the economic stability worldwide. The advancement in tissue engineering is contributing a lot in dealing with this immediate need of alleviating human health. Blood vessel diseases are considered as major cardiovascular health problems. Although blood vessel transplantation is the most convenient treatment, it has been delimited due to scarcity of donors and the patient's conditions. However, tissue-engineered blood vessels are promising alternatives as mode of treatment for blood vessel defects. The purpose of this paper is to show the importance of the advancement on biofabrication technology for treatment of soft tissue defects particularly for vascular tissues. This will also provide an overview and update on the current status of tissue reconstruction especially from autologous stem cells, scaffolds, and scaffold-free cellular transplantable constructs. The discussion of this paper will be focused on the historical view of cardiovascular tissue engineering and stem cell biology. The representative studies featured in this paper are limited within the last decade in order to trace the trend and evolution of techniques for blood vessel tissue engineering. PMID:23251085

  2. An automated and robust image processing algorithm for glaucoma diagnosis from fundus images using novel blood vessel tracking and bend point detection.

    Science.gov (United States)

    M, Soorya; Issac, Ashish; Dutta, Malay Kishore

    2018-02-01

    Glaucoma is an ocular disease which can cause irreversible blindness. The disease is currently identified using specialized equipment operated by optometrists manually. The proposed work aims to provide an efficient imaging solution which can help in automating the process of Glaucoma diagnosis using computer vision techniques from digital fundus images. The proposed method segments the optic disc using a geometrical feature based strategic framework which improves the detection accuracy and makes the algorithm invariant to illumination and noise. Corner thresholding and point contour joining based novel methods are proposed to construct smooth contours of Optic Disc. Based on a clinical approach as used by ophthalmologist, the proposed algorithm tracks blood vessels inside the disc region and identifies the points at which first vessel bend from the optic disc boundary and connects them to obtain the contours of Optic Cup. The proposed method has been compared with the ground truth marked by the medical experts and the similarity parameters, used to determine the performance of the proposed method, have yield a high similarity of segmentation. The proposed method has achieved a macro-averaged f-score of 0.9485 and accuracy of 97.01% in correctly classifying fundus images. The proposed method is clinically significant and can be used for Glaucoma screening over a large population which will work in a real time. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Tracking blood vessels in human forearms using visual servoing

    DEFF Research Database (Denmark)

    Savarimuthu, Thiusius Rajeeth; Ellekilde, Lars-Peter; Hansen, Morten

    Drawing an average of more than 2 blood sample per Danish citizen per year increases the demand for an automatic blood sampling method. This paper presents a proof of concept to one of the main challenges in making a fully automated blood sampling procedure, namely: the patient movement compensat......Drawing an average of more than 2 blood sample per Danish citizen per year increases the demand for an automatic blood sampling method. This paper presents a proof of concept to one of the main challenges in making a fully automated blood sampling procedure, namely: the patient movement...... compensation. By using images taken with near-infrared light to locate the blood vessels in a human forearm and using the same images to detects movements of the arm, this paper shows that it is possible make a robot arm, potentially equipped with a needle for drawing the blood, compensate for the movements...

  4. Waves and fluid-solid interaction in stented blood vessels

    Science.gov (United States)

    Frecentese, S.; Argani, L. P.; Movchan, A. B.; Movchan, N. V.; Carta, G.; Wall, M. L.

    2018-01-01

    This paper focuses on the modelling of fluid-structure interaction and wave propagation problems in a stented artery. Reflection of waves in blood vessels is well documented in the literature, but it has always been linked to a strong variation in geometry, such as the branching of vessels. The aim of this work is to detect the possibility of wave reflection in a stented artery due to the repetitive pattern of the stents. The investigation of wave propagation and possible blockages under time-harmonic conditions is complemented with numerical simulations in the transient regime.

  5. Corrections for inhomogeneities in biological tissue caused by blood vessels

    NARCIS (Netherlands)

    Talsma, A; Chance, B; Graaff, R

    In tissue optics, the assumption that blood is homogeneously distributed in tissue can give rise to miscalculations because blood is found only in blood vessels. In our paper randomly oriented blood vessels are treated as particles for which we obtained apparent absorption and scattering

  6. Blood Vessel-Derived Acellular Matrix for Vascular Graft Application

    Directory of Open Access Journals (Sweden)

    Luigi Dall’Olmo

    2014-01-01

    Full Text Available To overcome the issues connected to the use of autologous vascular grafts and artificial materials for reconstruction of small diameter (<6 mm blood vessels, this study aimed to develop acellular matrix- (AM- based vascular grafts. Rat iliac arteries were decellularized by a detergent-enzymatic treatment, whereas endothelial cells (ECs were obtained through enzymatic digestion of rat skin followed by immunomagnetic separation of CD31-positive cells. Sixteen female Lewis rats (8 weeks old received only AM or previously in vitro reendothelialized AM as abdominal aorta interposition grafts (about 1 cm. The detergent-enzymatic treatment completely removed the cellular part of vessels and both MHC class I and class II antigens. One month after surgery, the luminal surface of implanted AMs was partially covered by ECs and several platelets adhered in the areas lacking cell coverage. Intimal hyperplasia, already detected after 1 month, increased at 3 months. On the contrary, all grafts composed by AM and ECs were completely covered at 1 month and their structure was similar to that of native vessels at 3 months. Taken together, our findings show that prostheses composed of AM preseeded with ECs could be a promising approach for the replacement of blood vessels.

  7. Bone marrow blood vessels: normal and neoplastic niche

    Directory of Open Access Journals (Sweden)

    Saeid Shahrabi

    2016-11-01

    Full Text Available Blood vessels are among the most important factors in the transport of materials such as nutrients and oxygen. This study will review the role of blood vessels in normal bone marrow hematopoiesis as well as pathological conditions like leukemia and metastasis. Relevant literature was identified by a Pubmed search (1992-2016 of English-language papers using the terms bone marrow, leukemia, metastasis, and vessel. Given that blood vessels are conduits for the transfer of nutrients, they create a favorable situation for cancer cells and cause their growth and development. On the other hand, blood vessels protect leukemia cells against chemotherapy drugs. Finally, it may be concluded that the vessels are an important factor in the development of malignant diseases.

  8. Blood vessel classification into arteries and veins in retinal images

    Science.gov (United States)

    Kondermann, Claudia; Kondermann, Daniel; Yan, Michelle

    2007-03-01

    The prevalence of diabetes is expected to increase dramatically in coming years; already today it accounts for a major proportion of the health care budget in many countries. Diabetic Retinopathy (DR), a micro vascular complication very often seen in diabetes patients, is the most common cause of visual loss in working age population of developed countries today. Since the possibility of slowing or even stopping the progress of this disease depends on the early detection of DR, an automatic analysis of fundus images would be of great help to the ophthalmologist due to the small size of the symptoms and the large number of patients. An important symptom for DR are abnormally wide veins leading to an unusually low ratio of the average diameter of arteries to veins (AVR). There are also other diseases like high blood pressure or diseases of the pancreas with one symptom being an abnormal AVR value. To determine it, a classification of vessels as arteries or veins is indispensable. As to our knowledge despite the importance there have only been two approaches to vessel classification yet. Therefore we propose an improved method. We compare two feature extraction methods and two classification methods based on support vector machines and neural networks. Given a hand-segmentation of vessels our approach achieves 95.32% correctly classified vessel pixels. This value decreases by 10% on average, if the result of a segmentation algorithm is used as basis for the classification.

  9. Vessel discoloration detection in malarial retinopathy

    Science.gov (United States)

    Agurto, C.; Nemeth, S.; Barriga, S.; Soliz, P.; MacCormick, I.; Taylor, T.; Harding, S.; Lewallen, S.; Joshi, V.

    2016-03-01

    Cerebral malaria (CM) is a life-threatening clinical syndrome associated with malarial infection. It affects approximately 200 million people, mostly sub-Saharan African children under five years of age. Malarial retinopathy (MR) is a condition in which lesions such as whitening and vessel discoloration that are highly specific to CM appear in the retina. Other unrelated diseases can present with symptoms similar to CM, therefore the exact nature of the clinical symptoms must be ascertained in order to avoid misdiagnosis, which can lead to inappropriate treatment and, potentially, death. In this paper we outline the first system to detect the presence of discolored vessels associated with MR as a means to improve the CM diagnosis. We modified and improved our previous vessel segmentation algorithm by incorporating the `a' channel of the CIELab color space and noise reduction. We then divided the segmented vasculature into vessel segments and extracted features at the wall and in the centerline of the segment. Finally, we used a regression classifier to sort the segments into discolored and not-discolored vessel classes. By counting the abnormal vessel segments in each image, we were able to divide the analyzed images into two groups: normal and presence of vessel discoloration due to MR. We achieved an accuracy of 85% with sensitivity of 94% and specificity of 67%. In clinical practice, this algorithm would be combined with other MR retinal pathology detection algorithms. Therefore, a high specificity can be achieved. By choosing a different operating point in the ROC curve, our system achieved sensitivity of 67% with specificity of 100%.

  10. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W. Sr.

    1992-01-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system use relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, Monte Carlo calculations were performed using the code Electron Gamma Shower (EGS4). Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessel sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was or cross fire between blood vessels was assumed. Results are useful in assessing the doses to blood and blood vessel walls for different nuclear medicine procedures

  11. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W.

    1991-05-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system used relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, EGS4 Monte Carlo calculations were performed. Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessels sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was assumed nor cross fire between vessel was assumed. Results are useful in assessing the dose in blood and blood vessel walls for different nuclear medicine procedures. 6 refs., 6 figs., 5 tabs

  12. Instability and `Sausage-String' Appearance in Blood Vessels during High Blood Pressure

    OpenAIRE

    Alstrom, Preben; Eguiluz, Victor M.; Colding-Jorgensen, Morten; Gustafsson, Finn; Holstein-Rathlou, Niels-Henrik

    1998-01-01

    A new Rayleigh-type instability is proposed to explain the `sausage-string' pattern of alternating constrictions and dilatations formed in blood vessels under influence of a vasoconstricting agent. Our theory involves the nonlinear elasticity characteristics of the vessel wall, and provides predictions for the conditions under which the cylindrical form of a blood vessel becomes unstable.

  13. Vasodilator effect of nicorandil on retinal blood vessels in rats.

    Science.gov (United States)

    Ogawa, Naoto; Saito, Maki; Mori, Asami; Sakamoto, Kenji; Kametaka, Sokichi; Nakahara, Tsutomu; Ishii, Kunio

    2007-07-01

    We examined the effect of nicorandil on retinal blood vessels in rats in vivo. Male Wistar rats (8 to 10 weeks old) were anaesthetised with thiobutabarbital (120 mg/kg, intraperitoneal). Fundus images were captured with a digital camera that was equipped with a special objective lens. Diameters of retinal blood vessels were measured with a personal computer. Nicorandil (1-300 microg kg(-1) min(-1), intravenous [i.v.]) increased diameters of retinal blood vessels and decreased systemic blood pressure in a dose-dependent manner. Both responses to nicorandil were attenuated by glibenclamide (20 mg/kg, i.v.), an adenosine triphosphate (ATP)-dependent K(+) (K(ATP)) channel blocker. On the other hand, indomethacin (5 mg/kg, i.v.), a cyclooxygenase inhibitor, attenuated the vasodilation of retinal blood vessels, but not depressor response, to nicorandil and sodium nitroprusside. Pinacidil (1-300 microg kg(-1) min(-1), i.v.), a K(ATP) channel opener, also dilated retinal blood vessels and decreased systemic blood pressure. The responses to pinacidil were prevented by glibenclamide, but not by indomethacin. The vasodilation of retinal arteriole, but not depressor response, to sodium nitroprusside (1-30 microg kg(-1) min(-1), i.v.), a nitric oxide donor, was attenuated by indomethacin. These results suggest that nicorandil dilates retinal blood vessels through opening of K(ATP) channels and production of prostaglandins that are probably generated by nitric oxide.

  14. Recovery of testicular blood flow following ligation of testicular vessels

    International Nuclear Information System (INIS)

    Pascual, J.A.; Villanueva-Meyer, J.; Salido, E.; Ehrlich, R.M.; Mena, I.; Rajfer, J.

    1989-01-01

    To determine whether initial ligation of the testicular vessels of the high undescended testis followed by a delayed secondary orchiopexy is a viable alternative to the classical Fowler-Stephens procedure, a series of preliminary experiments were conducted in the rat in which testicular blood flow was measured by the 133-xenon washout technique before, and 1 hour and 30 days after ligation of the vessels. In addition, testicular histology, and testis and sex-accessory tissue weights were measured in 6 control, 6 sham operated and 6 testicular vessel ligated rats 54 days after vessel ligation. The data demonstrate that ligation and division of the testicular blood vessels produce an 80 per cent decrease in testicular blood flow 1 hour after ligation of the vessels. However, 30 days later testis blood flow returns to the control and pre-treatment value. There were no significant changes in testis or sex-accessory tissue weights 54 days after vessel ligation. Histologically, 4 of the surgically operated testes demonstrated necrosis of less than 25 per cent of the seminiferous tubules while 1 testis demonstrated more than 75 per cent necrosis. The rest of the tubules in all 6 testes demonstrated normal spermatogenesis. From this study we conclude that initial testicular vessel ligation produces an immediate decrease in testicular blood flow but with time the collateral vessels are able to compensate and return the testis blood flow to its normal pre-treatment value. These preliminary observations lend support for the concept that initial ligation of the testicular vessels followed by a delayed secondary orchiopexy in patients with a high undescended testis may be a possible alternative to the classical Fowler-Stephens approach

  15. Aging changes in the heart and blood vessels

    Science.gov (United States)

    ... vessels URL of this page: //medlineplus.gov/ency/article/004006.htm Aging changes in the heart and blood vessels To ... changes in the heart include deposits of the "aging pigment," lipofuscin . The heart muscle cells degenerate slightly. The valves inside the heart, which ...

  16. A Computational Model Predicting Disruption of Blood Vessel Development

    Science.gov (United States)

    Vascular development is a complex process regulated by dynamic biological networks that vary in topology and state across different tissues and developmental stages. Signals regulating de novo blood vessel formation (vasculogenesis) and remodeling (angiogenesis) come from a varie...

  17. Fluid and mass transport in a single lymphatic blood vessel

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1987-08-01

    The problem considers the single blood vessel model in pulmonary circulation in the presence of gravitation and mass transfer. The tissue surrounding the blood vessel is modelled as a permeable medium distinct from the blood vessel which is a normal free space. On the assumption that the mass concentration varies slowly at the interface between the blood vessel and the tissue, the problem is tackled by asymptotic approximation. A crucial point of the analysis is the dependence of the flow variables on the permeability K of the tissue in a completely arbitrary manner. A primary conjecture of the study is the intimacy of the pathological pulmonary edema and the parameter K. (author). 4 refs

  18. Intra-epithelially entrapped blood vessels in ameloblastoma.

    Science.gov (United States)

    Siar, Chong Huat; Ishak, Ismadi; Ng, Kok Han

    2015-05-01

    The ameloblastoma is a benign but locally aggressive odontogenic neoplasm with a high recurrence rate. While significant progress has been made in our understanding regarding the role of tumoral vasculature relative to the diverse behavioral characteristics of this tumor, no attention has been paid to a distinct subset of blood vessels entrapped within its epithelial compartment. As vascular niches are known to influence tumoral growth, clarification of these vessels is important. The objectives of this study were to investigate the morphologic characteristics of intra-epithelially entrapped blood vessels (IEBVs) in ameloblastoma and to speculate on their relevance. Here, we evaluated the frequency, microvessel density (MVD), morphology, and distribution pattern of IEBVs in 77 ameloblastoma of different subtypes based on their immunoreactivity for endothelial markers (CD34, CD31, CD105), vascular tight junction protein (claudin-5), pericyte [α-smooth muscle actin (α-sma)], and vascular basement membrane (collagen IV). IEBVs were heterogeneously detected in ameloblastoma. Their mean MVD (CD34 = 15.46 ± 7.25; CD31 = 15.8 ± 5.04; CD105 = 0.82 ± 0.51) showed no significant correlation with different subtypes, and between primary and recurrent tumors (P > 0.05). These microvessels may occur as single/clusters of capillary sprouts, or formed compressed branching/non-branching slits entrapped within the epithelial compartment, and in direct apposition with polyhedral/granular neoplastic epithelial cells. They expressed proteins for endothelial tight junctions (claudin-5-positive) and pericytes (α-sma-positive) but had deficient basement membrane (collagen IV weak to absent). Aberrant expression for CD34, CD31, and CD105 in tumor epithelium was variably observed. Although rare in occurrence, identification of IEBVs in ameloblastoma could potentially represent a new paradigm for vascular assessment of this neoplasm. © 2014 John Wiley & Sons A/S. Published by John

  19. Blood Vessel Enhancement and Segmentation for Screening of Diabetic Retinopathy

    Directory of Open Access Journals (Sweden)

    Ibaa Jamal

    2012-06-01

    Full Text Available Diabetic retinopathy is an eye disease caused by the increase of insulin in blood and it is one of the main cuases of blindness in idusterlized countries. It is a progressive disease and needs an early detection and treatment. Vascular pattern of human retina helps the ophthalmologists in automated screening and diagnosis of diabetic retinopathy. In this article, we present a method for vascular pattern ehnacement and segmentation. We present an automated system which uses wavelets to enhance the vascular pattern and then it applies a piecewise threshold probing and adaptive thresholding for vessel localization and segmentation respectively. The method is evaluated and tested using publicly available retinal databases and we further compare our method with already proposed techniques.

  20. Photoacoustic imaging of blood vessels with a double-ring sensor featuring a narrow angular aperture

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Hondebrink, Erwin; Steenbergen, Wiendelt; van Leeuwen, Ton; de Mul, F.F.M.

    2004-01-01

    A photoacoustic double-ring sensor, featuring a narrow angular aperture, is developed for laser-induced photoacoustic imaging of blood vessels. An integrated optical fiber enables reflection-mode detection of ultrasonic waves. By using the cross-correlation between the signals detected by the two

  1. An experimental system for the study of ultrasound exposure of isolated blood vessels

    International Nuclear Information System (INIS)

    Tokarczyk, Anna; Rivens, Ian; Symonds-Tayler, Richard; Ter Haar, Gail; Van Bavel, E

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels. (paper)

  2. An experimental system for the study of ultrasound exposure of isolated blood vessels

    Science.gov (United States)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-04-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels.

  3. Locating abnormalities in brain blood vessels using parallel computing architecture.

    Science.gov (United States)

    Adeshina, A M; Hashim, R; Khalid, N E A; Abidin, S Z Z

    2012-09-01

    CT and MRI scans are widely used in medical diagnosis procedures, but they only produce 2-D images. However, the human anatomical structure, the abnormalities, tumors, tissues and organs are in 3-D. 2-D images from these devices are difficult to interpret because they only show cross-sectional views of the human structure. Consequently, such circumstances require doctors to use their expert experiences in the interpretation of the possible location, size or shape of the abnormalities, even for large datasets of enormous amount of slices. Previously, the concept of reconstructing 2-D images to 3-D was introduced. However, such reconstruction model requires high performance computation, may either be time-consuming or costly. Furthermore, detecting the internal features of human anatomical structure, such as the imaging of the blood vessels, is still an open topic in the computer-aided diagnosis of disorders and pathologies. This paper proposes a volume visualization framework using Compute Unified Device Architecture (CUDA), augmenting the widely proven ray casting technique in terms of superior qualities of images but with slow speed. Considering the rapid development of technology in the medical community, our framework is implemented on Microsoft.NET environment for easy interoperability with other emerging revolutionary tools. The framework was evaluated with brain datasets from the department of Surgery, University of North Carolina, United States, containing around 109 MRA datasets. Uniquely, at a reasonably cheaper cost, our framework achieves immediate reconstruction and obvious mappings of the internal features of human brain, reliable enough for instantaneous locations of possible blockages in the brain blood vessels.

  4. DETECTING VESSELS CARRYING MIGRANTS USING MACHINE LEARNING

    Directory of Open Access Journals (Sweden)

    A. Sfyridis

    2017-10-01

    Full Text Available Political instability, conflicts and inequalities result into significant flows of people worldwide, moving to different countries in search of a better life, safety or to be reunited with their families. Irregular crossings into Europe via sea routes, despite not being new, have recently increased together with the loss of lives of people in the attempt to reach EU shores. This highlights the need to find ways to improve the understanding of what is happening at sea. This paper, intends to expand the knowledge available on practices among smugglers and contribute to early warning and maritime situational awareness. By identifying smuggling techniques and based on anomaly detection methods, behaviours of interest are modelled and one class support vector machines are used to classify unlabelled data and detect potential smuggling vessels. Nine vessels are identified as potentially carrying irregular migrants and refugees. Though, further inspection of the results highlights possible misclassifications caused by data gaps and limited knowledge on smuggling tactics. Accepted classifications are considered subject to further investigation by the authorities.

  5. Detecting Vessels Carrying Migrants Using Machine Learning

    Science.gov (United States)

    Sfyridis, A.; Cheng, T.; Vespe, M.

    2017-10-01

    Political instability, conflicts and inequalities result into significant flows of people worldwide, moving to different countries in search of a better life, safety or to be reunited with their families. Irregular crossings into Europe via sea routes, despite not being new, have recently increased together with the loss of lives of people in the attempt to reach EU shores. This highlights the need to find ways to improve the understanding of what is happening at sea. This paper, intends to expand the knowledge available on practices among smugglers and contribute to early warning and maritime situational awareness. By identifying smuggling techniques and based on anomaly detection methods, behaviours of interest are modelled and one class support vector machines are used to classify unlabelled data and detect potential smuggling vessels. Nine vessels are identified as potentially carrying irregular migrants and refugees. Though, further inspection of the results highlights possible misclassifications caused by data gaps and limited knowledge on smuggling tactics. Accepted classifications are considered subject to further investigation by the authorities.

  6. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure......PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...

  7. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  8. Acrolein generation stimulates hypercontraction in isolated human blood vessels.

    Science.gov (United States)

    Conklin, D J; Bhatnagar, A; Cowley, H R; Johnson, G H; Wiechmann, R J; Sayre, L M; Trent, M B; Boor, P J

    2006-12-15

    Increased risk of vasospasm, a spontaneous hyperconstriction, is associated with atherosclerosis, cigarette smoking, and hypertension-all conditions involving oxidative stress, lipid peroxidation, and inflammation. To test the role of the lipid peroxidation- and inflammation-derived aldehyde, acrolein, in human vasospasm, we developed an ex vivo model using human coronary artery bypass graft (CABG) blood vessels and a demonstrated acrolein precursor, allylamine. Allylamine induces hypercontraction in isolated rat coronary artery in a semicarbazide-sensitive amine oxidase activity (SSAO) dependent manner. Isolated human CABG blood vessels (internal mammary artery, radial artery, saphenous vein) were used to determine: (1) vessel responses and sensitivity to acrolein, allylamine, and H(2)O(2) exposure (1 microM-1 mM), (2) SSAO dependence of allylamine-induced effects using SSAO inhibitors (semicarbazide, 1 mM; MDL 72274-E, active isomer; MDL 72274-Z, inactive isomer; 100 microM), (3) the vasoactive effects of two other SSAO amine substrates, benzylamine and methylamine, and (4) the contribution of extracellular Ca(2+) to hypercontraction. Acrolein or allylamine but not H(2)O(2), benzylamine, or methylamine stimulated spontaneous and pharmacologically intractable hypercontraction in CABG blood vessels that was similar to clinical vasospasm. Allylamine-induced hypercontraction and blood vessel SSAO activity were abolished by pretreatment with semicarbazide or MDL 72274-E but not by MDL 72274-Z. Allylamine-induced hypercontraction also was significantly attenuated in Ca(2+)-free buffer. In isolated aorta of spontaneously hypertensive rat, allylamine-induced an SSAO-dependent contraction and enhanced norepinephrine sensitivity but not in Sprague-Dawley rat aorta. We conclude that acrolein generation in the blood vessel wall increases human susceptibility to vasospasm, an event that is enhanced in hypertension.

  9. Acrolein generation stimulates hypercontraction in isolated human blood vessels

    International Nuclear Information System (INIS)

    Conklin, D.J.; Bhatnagar, A.; Cowley, H.R.; Johnson, G.H.; Wiechmann, R.J.; Sayre, L.M.; Trent, M.B.; Boor, P.J.

    2006-01-01

    Increased risk of vasospasm, a spontaneous hyperconstriction, is associated with atherosclerosis, cigarette smoking, and hypertension-all conditions involving oxidative stress, lipid peroxidation, and inflammation. To test the role of the lipid peroxidation- and inflammation-derived aldehyde, acrolein, in human vasospasm, we developed an ex vivo model using human coronary artery bypass graft (CABG) blood vessels and a demonstrated acrolein precursor, allylamine. Allylamine induces hypercontraction in isolated rat coronary artery in a semicarbazide-sensitive amine oxidase activity (SSAO) dependent manner. Isolated human CABG blood vessels (internal mammary artery, radial artery, saphenous vein) were used to determine: (1) vessel responses and sensitivity to acrolein, allylamine, and H 2 O 2 exposure (1 μM-1 mM), (2) SSAO dependence of allylamine-induced effects using SSAO inhibitors (semicarbazide, 1 mM; MDL 72274-E, active isomer; MDL 72274-Z, inactive isomer; 100 μM), (3) the vasoactive effects of two other SSAO amine substrates, benzylamine and methylamine, and (4) the contribution of extracellular Ca 2+ to hypercontraction. Acrolein or allylamine but not H 2 O 2 , benzylamine, or methylamine stimulated spontaneous and pharmacologically intractable hypercontraction in CABG blood vessels that was similar to clinical vasospasm. Allylamine-induced hypercontraction and blood vessel SSAO activity were abolished by pretreatment with semicarbazide or MDL 72274-E but not by MDL 72274-Z. Allylamine-induced hypercontraction also was significantly attenuated in Ca 2+ -free buffer. In isolated aorta of spontaneously hypertensive rat, allylamine-induced an SSAO-dependent contraction and enhanced norepinephrine sensitivity but not in Sprague-Dawley rat aorta. We conclude that acrolein generation in the blood vessel wall increases human susceptibility to vasospasm, an event that is enhanced in hypertension

  10. Pericyte coverage of abnormal blood vessels in myelofibrotic bone marrows

    DEFF Research Database (Denmark)

    Zetterberg, Eva; Vannucchi, Alessandro M; Migliaccio, Anna Rita

    2007-01-01

    BACKGROUND AND OBJECTIVES: Myelofibrotic bone marrow displays abnormal angiogenesis but the pathogenic mechanisms of this are poorly understood. Since pericyte abnormalities are described on solid tumor vessels we studied whether vessel morphology and pericyte coverage in bone marrow samples from...... megakaryocytopoesis, wide, pericyte-coated and morphologically aberrant vessels were detected. MVD was significantly greater in bone marrow and spleen samples from animals with myelofibrosis than in wild-type mice. INTERPRETATION AND CONCLUSIONS: We conclude that angiogenesis is similarly abnormal in human and murine...... myelofibrosis with intense pericyte coating, presumably related to abnormal megakaryocytopoiesis....

  11. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    through image processing and data mining techniques. Retinal image data, which is given as input for data mining process is considered as Big Data since every pixel forms a tuple. Blood vessel network is segmented through color space conversion and channel extraction, image pre-processing, Gabor filtering, application ...

  12. Gene expression analysis in human breast cancer associated blood vessels.

    Directory of Open Access Journals (Sweden)

    Dylan T Jones

    Full Text Available Angiogenesis is essential for solid tumour growth, whilst the molecular profiles of tumour blood vessels have been reported to be different between cancer types. Although presently available anti-angiogenic strategies are providing some promise for the treatment of some cancers it is perhaps not surprisingly that, none of the anti-angiogenic agents available work on all tumours. Thus, the discovery of novel anti-angiogenic targets, relevant to individual cancer types, is required. Using Affymetrix microarray analysis of laser-captured, CD31-positive blood vessels we have identified 63 genes that are upregulated significantly (5-72 fold in angiogenic blood vessels associated with human invasive ductal carcinoma (IDC of the breast as compared with blood vessels in normal human breast. We tested the angiogenic capacity of a subset of these genes. Genes were selected based on either their known cellular functions, their enriched expression in endothelial cells and/or their sensitivity to anti-VEGF treatment; all features implicating their involvement in angiogenesis. For example, RRM2, a ribonucleotide reductase involved in DNA synthesis, was upregulated 32-fold in IDC-associated blood vessels; ATF1, a nuclear activating transcription factor involved in cellular growth and survival was upregulated 23-fold in IDC-associated blood vessels and HEX-B, a hexosaminidase involved in the breakdown of GM2 gangliosides, was upregulated 8-fold in IDC-associated blood vessels. Furthermore, in silico analysis confirmed that AFT1 and HEX-B also were enriched in endothelial cells when compared with non-endothelial cells. None of these genes have been reported previously to be involved in neovascularisation. However, our data establish that siRNA depletion of Rrm2, Atf1 or Hex-B had significant anti-angiogenic effects in VEGF-stimulated ex vivo mouse aortic ring assays. Overall, our results provide proof-of-principle that our approach can identify a cohort of

  13. Vessel segmentation and microaneurysm detection using discriminative dictionary learning and sparse representation.

    Science.gov (United States)

    Javidi, Malihe; Pourreza, Hamid-Reza; Harati, Ahad

    2017-02-01

    Diabetic retinopathy (DR) is a major cause of visual impairment, and the analysis of retinal image can assist patients to take action earlier when it is more likely to be effective. The accurate segmentation of blood vessels in the retinal image can diagnose DR directly. In this paper, a novel scheme for blood vessel segmentation based on discriminative dictionary learning (DDL) and sparse representation has been proposed. The proposed system yields a strong representation which contains the semantic concept of the image. To extract blood vessel, two separate dictionaries, for vessel and non-vessel, capable of providing reconstructive and discriminative information of the retinal image are learned. In the test step, an unseen retinal image is divided into overlapping patches and classified to vessel and non-vessel patches. Then, a voting scheme is applied to generate the binary vessel map. The proposed vessel segmentation method can achieve the accuracy of 95% and a sensitivity of 75% in the same range of specificity 97% on two public datasets. The results show that the proposed method can achieve comparable results to existing methods and decrease false positive vessels in abnormal retinal images with pathological regions. Microaneurysm (MA) is the earliest sign of DR that appears as a small red dot on the surface of the retina. Despite several attempts to develop automated MA detection systems, it is still a challenging problem. In this paper, a method for MA detection, which is similar to our vessel segmentation approach, is proposed. In our method, a candidate detection algorithm based on the Morlet wavelet is applied to identify all possible MA candidates. In the next step, two discriminative dictionaries with the ability to distinguish MA from non-MA object are learned. These dictionaries are then used to classify the detected candidate objects. The evaluations indicate that the proposed MA detection method achieves higher average sensitivity about 2

  14. An automated blood vessel segmentation algorithm using histogram equalization and automatic threshold selection.

    Science.gov (United States)

    Saleh, Marwan D; Eswaran, C; Mueen, Ahmed

    2011-08-01

    This paper focuses on the detection of retinal blood vessels which play a vital role in reducing the proliferative diabetic retinopathy and for preventing the loss of visual capability. The proposed algorithm which takes advantage of the powerful preprocessing techniques such as the contrast enhancement and thresholding offers an automated segmentation procedure for retinal blood vessels. To evaluate the performance of the new algorithm, experiments are conducted on 40 images collected from DRIVE database. The results show that the proposed algorithm performs better than the other known algorithms in terms of accuracy. Furthermore, the proposed algorithm being simple and easy to implement, is best suited for fast processing applications.

  15. Three-dimensional display of blood vessels and soft tissues with MR images

    International Nuclear Information System (INIS)

    Shiotani, Y.; Sato, H.; Machida, Y.; Yoshida, T.

    1988-01-01

    The authors developed a three-dimensional display technique for blood vessels related to soft tissues, using MR images generated by the three-dimensional Fourier transform method or multisection method. An application of this study for neurosurgery provided satisfactory results. In this paper they describe this display technique and its clinical practice, including procedures (1) to enhance blood vessels by nonlinear filter capable of detecting three-dimensional line patterns without losing the form of soft tissues, (2) to generate three-dimensional images by the numerical projection, and (3) to present three-dimensional display utilizing the dynamic or binocular parallex (animation display or stereoscopic display). This technique facilitates the recognition of the three-dimensional structure of blood vessels related to soft tissues

  16. Atherosclerosis of coronary blood vessels - local or systemic inflamation?

    Science.gov (United States)

    Pejkov, Hristo; Kedev, Sasko; Panov, Saso; Srbinovska-Kostovska, Elizabeta; Lang, Irene

    2013-01-01

    The presence of atherosclerotic lesions in the blood vessels is a predisposition for the development and occurrence of acute ischaemic attacks. Bigger atherosclerotic lesions in the coronary blood vessels cause lumen occlusion, which is a cause of acute myocardial infarction. Endothelial dysfunction is defined as an ability of the endothelium to produce vasorelaxing nitric oxide (NO), or deregulation of the other vasoactive substances, such as angiotensin II and endothelin [13]. This definition describes endothelial dysfunction as an improper vasomotor constriction of the vessel, that leads to lumen occlusion of the already existing atherosclerotic lesions. According to the modern model, the development of atherosclerotic plaque and inappropriate endothelial NO production have a synergistic role in patho-physiological and molecular processes in the blood vessels [14]. Lesions in the coronary arteries are deposits of huge quantities of foamy cells and fibrous plaques. The thin fibrous plaques are 10-20% of the total plaque population and are the cause of 80-90% of clinical cases due to their ability to rupture [48]. According to all the results from published studies by far, it has been pointed out that the plaque stability, not the absolute size influences the rupture potential. Elucidating the risk factors that may modify in the atherogenesis and the consequent atherothrombic effect is the first step to this goal.

  17. Objective detection of retinal vessel pulsation.

    Directory of Open Access Journals (Sweden)

    William H Morgan

    Full Text Available PURPOSE: Retinal venous pulsation detection is a subjective sign, which varies in elevated intracranial pressure, venous obstruction and glaucoma. To date no method can objectively measure and identify pulsating regions. METHOD: Using high resolution video-recordings of the optic disk and retina we measured fluctuating light absorption by haemoglobin during pulsation. Pulsation amplitude was calculated from all regions of the retinal image video-frames in a raster pattern. Segmented retinal images were formed by objectively selecting regions with amplitudes above a range of threshold values. These were compared to two observers manually drawing an outline of the pulsating areas while viewing video-clips in order to generate receiver operator characteristics. RESULTS: 216,515 image segments were analysed from 26 eyes in 18 research participants. Using data from each eye, the median area under the receiver operator curve (AU-ROC was 0.95. With all data analysed together the AU-ROC was 0.89. We defined the ideal threshold amplitude for detection of any pulsating segment being that with maximal sensitivity and specificity. This was 5 units (95% confidence interval 4.3 to 6.0 compared to 12 units before any regions were missed. A multivariate model demonstrated that ideal threshold amplitude increased with increased variation in video-sequence illumination (p = 0.0119, but between the two observers (p = 0.0919 or other variables. CONCLUSION: This technique demonstrates accurate identification of retinal vessel pulsating regions with no areas identified manually being missed with the objective technique. The amplitude values are derived objectively and may be a significant advance upon subjective ophthalmodynamometric threshold techniques.

  18. Blood vessel modeling for interactive simulation of interventional neuroradiology procedures.

    Science.gov (United States)

    Kerrien, E; Yureidini, A; Dequidt, J; Duriez, C; Anxionnat, R; Cotin, S

    2017-01-01

    Endovascular interventions can benefit from interactive simulation in their training phase but also during pre-operative and intra-operative phases if simulation scenarios are based on patient data. A key feature in this context is the ability to extract, from patient images, models of blood vessels that impede neither the realism nor the performance of simulation. This paper addresses both the segmentation and reconstruction of the vasculature from 3D Rotational Angiography data, and adapted to simulation: An original tracking algorithm is proposed to segment the vessel tree while filtering points extracted at the vessel surface in the vicinity of each point on the centerline; then an automatic procedure is described to reconstruct each local unstructured point set as a skeleton-based implicit surface (blobby model). The output of successively applying both algorithms is a new model of vasculature as a tree of local implicit models. The segmentation algorithm is compared with Multiple Hypothesis Testing (MHT) algorithm (Friman et al., 2010) on patient data, showing its greater ability to track blood vessels. The reconstruction algorithm is evaluated on both synthetic and patient data and demonstrate its ability to fit points with a subvoxel precision. Various tests are also reported where our model is used to simulate catheter navigation in interventional neuroradiology. An excellent realism, and much lower computational costs are reported when compared to triangular mesh surface models. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Migraine aura pathophysiology: the role of blood vessels and microembolisation

    OpenAIRE

    Dalkara, Turgay; Nozari, Ala; Moskowitz, Michael A

    2010-01-01

    Migraine attacks with auras are sometimes associated with underlying hereditary or acquired cerebrovascular disorders. A unifying pathophysiological explanation linking migraine to these conditions has been diffcult to identify. On the basis of genetic and epidemiological evidence, we suggest that changes in blood vessels, hypoperfusion disorders, and microembolisation can cause neurovascular dysfunction and evoke cortical spreading depression, an event that is widely thought to underlie aura...

  20. Acrolein generation stimulates hypercontraction in isolated human blood vessels

    OpenAIRE

    Conklin, D.J.; Bhatnagar, A.; Cowley, H.R.; Johnson, G.H.; Wiechmann, R.J.; Sayre, L.M.; Trent, M.B.; Boor, P.J.

    2006-01-01

    Increased risk of vasospasm, a spontaneous hyperconstriction, is associated with atherosclerosis, cigarette smoking, and hypertension—all conditions involving oxidative stress, lipid peroxidation, and inflammation. To test the role of the lipid peroxidation- and inflammation-derived aldehyde, acrolein, in human vasospasm, we developed an ex vivo model using human coronary artery bypass graft (CABG) blood vessels and a demonstrated acrolein precursor, allylamine. Allylamine induces hypercontra...

  1. Historical Perspective and Future Direction of Blood Vessel Developments.

    Science.gov (United States)

    Dimitrievska, Sashka; Niklason, Laura E

    2018-02-01

    Over the past 40 years, remarkable advances have been made in our understanding of successful blood vessel regeneration, starting with the failures of early tissue-engineered vascular grafts designed using isolated components or molecules, such as collagen gels. The vascular tissue engineers are today better educated and have steered ongoing research developments toward clinical developments of more complete vascular grafts that replicate the multitude of specialized arterial aspects required for function. Copyright © 2018 Cold Spring Harbor Laboratory Press; all rights reserved.

  2. DLC coating of textile blood vessels using PLD

    Czech Academy of Sciences Publication Activity Database

    Kocourek, Tomáš; Jelínek, Miroslav; Vorlíček, Vladimír; Zemek, Josef; Janča, T.; Žížková, V.; Podlaha, J.; Popov, C.

    2008-01-01

    Roč. 93, č. 3 (2008), s. 627-632 ISSN 0947-8396 R&D Projects: GA MPO FI-IM2/068; GA ČR GA202/06/0216 Institutional research plan: CEZ:AV0Z10100522 Keywords : blood vessels * PLD * DLC * sp2 * sp3 Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.884, year: 2008

  3. Leptospirosis-associated disturbances of blood vessels, lungs and hemostasis.

    Science.gov (United States)

    Medeiros, Fernanda da Rocha; Spichler, Anne; Athanazio, Daniel A

    2010-01-01

    The frequency of massive pulmonary hemorrhages seems to be increasing in different geographic areas; however, there is no clear explanation for this trend. Although data on the pathogenesis of such complications are scarce, recent research indicates a potential role of autoimmunity and/or multifactorial mechanisms. However, much information is already available on the disturbance of hemostasis and blood vessels in leptospirosis-related literature, even if some contradictory concepts coexist. The purpose of this review is to integrate both new and classical information from human and animal studies on severe pulmonary forms of leptospirosis and disorders of hemostasis and blood vessels. We propose that the involvement of blood vessels in leptospirosis must be understood as a sepsis-like, diffuse process of endothelial activation/damage rather than as a classical systemic vasculitis. Pulmonary hemorrhages are most likely multifactorial and there has recently been evidence against the role of autoimmunity; however, further investigation of strain variations, exposure to hydrocarbons and association with renal dysfunction is required. Thrombocytopenia is a consistent feature of leptospirosis but it is not clear whether it is attributable to sepsis-related mechanisms. In addition, further investigation is required to define whether platelet function is activated or inhibited during severe leptospirosis. 2010 Elsevier B.V. All rights reserved.

  4. ROI DETECTION AND VESSEL SEGMENTATION IN RETINAL IMAGE

    Directory of Open Access Journals (Sweden)

    F. Sabaz

    2017-11-01

    Full Text Available Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  5. Roi Detection and Vessel Segmentation in Retinal Image

    Science.gov (United States)

    Sabaz, F.; Atila, U.

    2017-11-01

    Diabetes disrupts work by affecting the structure of the eye and afterwards leads to loss of vision. Depending on the stage of disease that called diabetic retinopathy, there are sudden loss of vision and blurred vision problems. Automated detection of vessels in retinal images is a useful study to diagnose eye diseases, disease classification and other clinical trials. The shape and structure of the vessels give information about the severity of the disease and the stage of the disease. Automatic and fast detection of vessels allows for a quick diagnosis of the disease and the treatment process to start shortly. ROI detection and vessel extraction methods for retinal image are mentioned in this study. It is shown that the Frangi filter used in image processing can be successfully used in detection and extraction of vessels.

  6. Mass Spectrometry and Antibody-Based Characterization of Blood Vessels from Brachylophosaurus canadensis.

    Science.gov (United States)

    Cleland, Timothy P; Schroeter, Elena R; Zamdborg, Leonid; Zheng, Wenxia; Lee, Ji Eun; Tran, John C; Bern, Marshall; Duncan, Michael B; Lebleu, Valerie S; Ahlf, Dorothy R; Thomas, Paul M; Kalluri, Raghu; Kelleher, Neil L; Schweitzer, Mary H

    2015-12-04

    Structures similar to blood vessels in location, morphology, flexibility, and transparency have been recovered after demineralization of multiple dinosaur cortical bone fragments from multiple specimens, some of which are as old as 80 Ma. These structures were hypothesized to be either endogenous to the bone (i.e., of vascular origin) or the result of biofilm colonizing the empty osteonal network after degradation of original organic components. Here, we test the hypothesis that these structures are endogenous and thus retain proteins in common with extant archosaur blood vessels that can be detected with high-resolution mass spectrometry and confirmed by immunofluorescence. Two lines of evidence support this hypothesis. First, peptide sequencing of Brachylophosaurus canadensis blood vessel extracts is consistent with peptides comprising extant archosaurian blood vessels and is not consistent with a bacterial, cellular slime mold, or fungal origin. Second, proteins identified by mass spectrometry can be localized to the tissues using antibodies specific to these proteins, validating their identity. Data are available via ProteomeXchange with identifier PXD001738.

  7. Blood vessel extraction and optic disc removal using curvelet transform and kernel fuzzy c-means.

    Science.gov (United States)

    Kar, Sudeshna Sil; Maity, Santi P

    2016-03-01

    This paper proposes an automatic blood vessel extraction method on retinal images using matched filtering in an integrated system design platform that involves curvelet transform and kernel based fuzzy c-means. Since curvelet transform represents the lines, the edges and the curvatures very well and in compact form (by less number of coefficients) compared to other multi-resolution techniques, this paper uses curvelet transform for enhancement of the retinal vasculature. Matched filtering is then used to intensify the blood vessels' response which is further employed by kernel based fuzzy c-means algorithm that extracts the vessel silhouette from the background through non-linear mapping. For pathological images, in addition to matched filtering, Laplacian of Gaussian filter is also employed to distinguish the step and the ramp like signal from that of vessel structure. To test the efficacy of the proposed method, the algorithm has also been applied to images in presence of additive white Gaussian noise where the curvelet transform has been used for image denoising. Performance is evaluated on publicly available DRIVE, STARE and DIARETDB1 databases and is compared with the large number of existing blood vessel extraction methodologies. Simulation results demonstrate that the proposed method is very much efficient in detecting the long and the thick as well as the short and the thin vessels with an average accuracy of 96.16% for the DRIVE and 97.35% for the STARE database wherein the existing methods fail to extract the tiny and the thin vessels. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Angiogenesis and blood vessel stability in inflammatory arthritis.

    LENUS (Irish Health Repository)

    Kennedy, Aisling

    2012-02-01

    OBJECTIVE: To assess blood vessel stability in inflammatory synovial tissue (ST) and to examine neural cell adhesion molecule (NCAM), oxidative DNA damage, and hypoxia in vivo. METHODS: Macroscopic vascularity and ST oxygen levels were determined in vivo in patients with inflammatory arthritis who were undergoing arthroscopy. Vessel maturity\\/stability was quantified in matched ST samples by dual immunofluorescence staining for factor VIII (FVIII)\\/alpha-smooth muscle actin (alpha-SMA). NCAM and 8-oxo-7,8-dihydro-2\\'-deoxyguanosine (8-oxodG) were examined by immunohistochemistry. Angiogenesis was assessed in vitro, using human dermal endothelial cells (HDECs) in a Matrigel tube formation assay. RESULTS: A significant number of immature vessels (showing no pericyte recruitment) was observed in tissue from patients with inflammatory arthritis (P < 0.001), in contrast to osteoarthritic and normal tissue, which showed complete recruitment of pericytes. Low in vivo PO(2) levels in the inflamed joint (median [range] 22.8 [3.2-54.1] mm Hg) were inversely related to increased macroscopic vascularity (P < 0.04) and increased microscopic expression of FVIII and alpha-SMA (P < 0.04 and P < 0.03, respectively). A significant proportion of vessels showed focal expression of NCAM and strong nuclear 8-oxodG expression, implicating a loss of EC-pericyte contact and increased DNA damage, levels of which were inversely associated with low in vivo PO(2) (P = 0.04 for each comparison). Circulating cells were completely negative for 8-oxodG. Exposure of HDEC to 3% O(2) (reflecting mean ST in vivo measurements) significantly increased EC tube formation (P < 0.05). CONCLUSION: Our findings indicate the presence of unstable vessels in inflamed joints associated with hypoxia, incomplete EC-pericyte interactions, and increased DNA damage. These changes may further contribute to persistent hypoxia in the inflamed joint to further drive this unstable microenvironment.

  9. An artificial blood vessel implanted three-dimensional microsystem for modeling transvascular migration of tumor cells.

    Science.gov (United States)

    Wang, Xue-Ying; Pei, Ying; Xie, Min; Jin, Zi-He; Xiao, Ya-Shi; Wang, Yang; Zhang, Li-Na; Li, Yan; Huang, Wei-Hua

    2015-02-21

    Reproducing a tumor microenvironment consisting of blood vessels and tumor cells for modeling tumor invasion in vitro is particularly challenging. Here, we report an artificial blood vessel implanted 3D microfluidic system for reproducing transvascular migration of tumor cells. The transparent, porous and elastic artificial blood vessels are obtained by constructing polysaccharide cellulose-based microtubes using a chitosan sacrificial template, and possess excellent cytocompatibility, permeability, and mechanical characteristics. The artificial blood vessels are then fully implanted into the collagen matrix to reconstruct the 3D microsystem for modeling transvascular migration of tumor cells. Well-defined simulated vascular lumens were obtained by proliferation of the human umbilical vein endothelial cells (HUVECs) lining the artificial blood vessels, which enables us to reproduce structures and functions of blood vessels and replicate various hemodynamic parameters. Based on this model, the adhesion and transvascular migration of tumor cells across the artificial blood vessel have been well reproduced.

  10. The influence of the blood vessel diameter on the full scattering profile from cylindrical tissues: experimental evidence for the shielding effect.

    Science.gov (United States)

    Feder, Idit; Duadi, Hamootal; Dreifuss, Tamar; Fixler, Dror

    2016-10-01

    Optical methods for detecting physiological state based on light-tissue interaction are noninvasive, inexpensive, simplistic, and thus very useful. The blood vessels in human tissue are the main cause of light absorbing and scattering. Therefore, the effect of blood vessels on light-tissue interactions is essential for optically detecting physiological tissue state, such as oxygen saturation, blood perfusion and blood pressure. We have previously suggested a new theoretical and experimental method for measuring the full scattering profile, which is the angular distribution of light intensity, of cylindrical tissues. In this work we will present experimental measurements of the full scattering profile of heterogenic cylindrical phantoms that include blood vessels. We show, for the first time that the vessel diameter influences the full scattering profile, and found higher reflection intensity for larger vessel diameters accordance to the shielding effect. For an increase of 60% in the vessel diameter the light intensity in the full scattering profile above 90° is between 9% to 40% higher, depending on the angle. By these results we claim that during respiration, when the blood-vessel diameter changes, it is essential to consider the blood-vessel diameter distribution in order to determine the optical path in tissues. A CT scan of the measured silicon-based phantoms. The phantoms contain the same blood volume in different blood-vessel diameters. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Skeletonization algorithm-based blood vessel quantification using in vivo 3D photoacoustic imaging

    Science.gov (United States)

    Meiburger, K. M.; Nam, S. Y.; Chung, E.; Suggs, L. J.; Emelianov, S. Y.; Molinari, F.

    2016-11-01

    Blood vessels are the only system to provide nutrients and oxygen to every part of the body. Many diseases can have significant effects on blood vessel formation, so that the vascular network can be a cue to assess malicious tumor and ischemic tissues. Various imaging techniques can visualize blood vessel structure, but their applications are often constrained by either expensive costs, contrast agents, ionizing radiations, or a combination of the above. Photoacoustic imaging combines the high-contrast and spectroscopic-based specificity of optical imaging with the high spatial resolution of ultrasound imaging, and image contrast depends on optical absorption. This enables the detection of light absorbing chromophores such as hemoglobin with a greater penetration depth compared to purely optical techniques. We present here a skeletonization algorithm for vessel architectural analysis using non-invasive photoacoustic 3D images acquired without the administration of any exogenous contrast agents. 3D photoacoustic images were acquired on rats (n  =  4) in two different time points: before and after a burn surgery. A skeletonization technique based on the application of a vesselness filter and medial axis extraction is proposed to extract the vessel structure from the image data and six vascular parameters (number of vascular trees (NT), vascular density (VD), number of branches (NB), 2D distance metric (DM), inflection count metric (ICM), and sum of angles metric (SOAM)) were calculated from the skeleton. The parameters were compared (1) in locations with and without the burn wound on the same day and (2) in the same anatomic location before (control) and after the burn surgery. Four out of the six descriptors were statistically different (VD, NB, DM, ICM, p  burn surgery). The study demonstrates an approach to obtain quantitative characterization of the vascular network from 3D photoacoustic images without any exogenous contrast agent which can assess

  12. War injuries of the blood vessels of the extremities

    Directory of Open Access Journals (Sweden)

    Radulović Svetozar

    2002-01-01

    Full Text Available Treatment results of 200 injured with the lesions of 282 magisterial blood vessels were analyzed. All were combat injuries, and the majority was caused by the fragments of explosive device. The mechanism of such the injuries produced large defects of soft tissues as well as the high level of the wound contamination, which aggravated reconstructive procedures and increased the risk of infection. In the majority of cases anatomic reconstruction of the artery was performed, and the ligature was used only in the case of graft infection and in the injuries of one artery of the lower leg or the forearm. The majority of injuries was solved by lateral suture or patch plastic, since postoperative constriction caused by those methods did not cause greater hemodynamic disorders due to the size of venous lumen. The duration of ischemic interval was of the utmost importance for the favorable final result of the treatment, as well as the adequate debridement of the wound, good soft-tissue cover of the reconstructed blood vessel and precise a traumatic technique. Total percentage of amputations was 14.5%, and all were involving the lower extremities, and were mostly caused by popliteal artery lesion.

  13. Vascular patterns in the heads of crocodilians: blood vessels and sites of thermal exchange.

    Science.gov (United States)

    Porter, William Ruger; Sedlmayr, Jayc C; Witmer, Lawrence M

    2016-12-01

    Extant crocodilians are a highly apomorphic archosaur clade that is ectothermic, yet often achieve large body sizes that can be subject to higher heat loads. Therefore, the anatomical and physiological roles that blood vessels play in crocodilian thermoregulation need further investigation to better understand how crocodilians establish and maintain cephalic temperatures and regulate neurosensory tissue temperatures during basking and normal activities. The cephalic vascular anatomy of extant crocodilians, particularly American alligator (Alligator mississippiensis) was investigated using a differential-contrast, dual-vascular injection technique and high resolution X-ray micro-computed tomography (μCT). Blood vessels were digitally isolated to create representations of vascular pathways. The specimens were then dissected to confirm CT results. Sites of thermal exchange, consisting of the oral, nasal, and orbital regions, were given special attention due to their role in evaporative cooling and cephalic thermoregulation in other diapsids. Blood vessels to and from sites of thermal exchange were studied to detect conserved vascular patterns and to assess their ability to deliver cooled blood to neurosensory tissues. Within the orbital region, both the arteries and veins demonstrated consistent branching patterns, with the supraorbital, infraorbital, and ophthalmotemporal vessels supplying and draining the orbit. The venous drainage of the orbital region showed connections to the dural sinuses via the orbital veins and cavernous sinus. The palatal region demonstrated a vast plexus that comprised both arteries and veins. The most direct route of venous drainage of the palatal plexus was through the palatomaxillary veins, essentially bypassing neurosensory tissues. Anastomotic connections with the nasal region, however, may provide an alternative route for palatal venous blood to reach neurosensory tissues. The nasal region in crocodilians is probably the most

  14. Calcification in arteriovenous fistula blood vessels may predict arteriovenous fistula failure: a 5-year follow-up study.

    Science.gov (United States)

    Jankovic, Aleksandar; Damjanovic, Tatjana; Djuric, Zivka; Marinkovic, Jelena; Schlieper, Georg; Djuric, Petar; Dragovic, Jelena Tosic; Bulatovic, Ana; Mitrovic, Milos; Popovic, Jovan; Floege, Jürgen; Dimkovic, Nada

    2017-05-01

    Arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis. The impact of vascular calcification process on AVF survival remains unclear and results of several studies about this issue are controversial. In the light of the new knowledge about the different susceptibility for calcification process in different blood vessels, the aim of our study was to analyze whether the calcification of AVF-blood vessels may have an impact on AVF longevity. The study included 90 patients, 49 males and 41 females, all of them Caucasians, with a mean age 62 ± 11 years, on regular hemodialysis for more than 1 year with patent primary AVFs. Vascular calcification in AVF-blood vessels or in the anastomotic region was detected using X-ray examination. Calcification in AVF-blood vessels was found in 62% of patients. Binary logistic regression analysis demonstrated that male gender, presence of diabetes mellitus and longer duration of AVF before calcification determination were associated with calcification of AVF-blood vessels. Using a Cox proportional hazard model adjusted for these standardized predicted values revealed that patients with present AVF-blood vessels calcification had increased risk to develop AVF failure with a hazard rate of 3.42 (95% confidence interval 1.00-11.67; P = 0.049). Calcifications of AVF-blood vessels are found frequently among dialysis patients and may jeopardize the survival of native AVF. We suggested the local X-ray as simple and valid method for detection of patients that are at risk for AVFs failure which should be monitored more closely.

  15. Pattern of blood vessels in eyes with coloboma

    Directory of Open Access Journals (Sweden)

    Gopal Lingam

    2013-01-01

    Full Text Available Background: Choroidal coloboma, especially with optic disc involvement affects the blood vessel (BV pattern in the fundus. Aim: The aim of this study was to report the observations on the pattern of retinal BVs in eyes with fundus coloboma. Design: Retrospective observational study. Materials and Methods: Twenty four eyes of 19 patients with fundus coloboma and the disc involvement in the coloboma was classified according to a previous publication. Results: Four varieties of BVs were identified in the area of coloboma - BVs that were continuous with those arising from the optic disc; vessels emanating from the floor of coloboma whose continuity with central retinal artery or its branches could be indirectly established; and those emanating from the floor of coloboma whose continuity with central retinal artery could not be established. In addition, extraocular BVs were visible through the thinned sclera. The retinal BVs often traversed the coloboma to reach the normal retina. The disc itself was found to be small and had no physiological cup (if not colobomatous. Conclusions: One should be aware of the major BVs transgressing the coloboma while performing relaxing cuts in the intercalary membrane, during the surgery for retinal detachments in eyes with coloboma. Physiological cup is usually absent (when the disc is not colobomatous. Hence, any cupping in such eyes should be viewed with suspicion.

  16. Computerized Reconstruction of Pulpal Blood Vessels Examined under Confocal Microscope

    Directory of Open Access Journals (Sweden)

    Digka Anna

    2015-03-01

    Full Text Available The purpose of this study was the evaluation of 3 different histological methods for studying pulpal blood vessels in combination with 2 types of confocal microscope and computer assisted 3-dimensional reconstruction. 10 human, healthy, free of restorations or caries teeth that were extracted for orthodontic reasons were used. From these teeth, the pulp tissues of 5 were removed, fixed in formalin solution, dehydrated and embedded in paraffin. Serial cross sections 5μm thick were taken from 3 of the above mentioned pulpal tissues and stained with CD34 according to the immunohistochemical ABC technique, while the rest 2 were stained with CD34 and Cy5 by means of immunofluorescence after serial cross sectioning of 10μm. 5 of the 10 teeth were fixed, decalcified, serial cross sectioned (30μm thickness and stained with eosin. The physical sections were examined under 2 types of confocal laser microscope. Serial images were taken for each section, alignment of the images was followed and finally 3-dimensional reconstructions of the pulpal vessels were achieved.

  17. Heterogeneity of muscarinic receptor subtypes in cerebral blood vessels

    International Nuclear Information System (INIS)

    Garcia-Villalon, A.L.; Krause, D.N.; Ehlert, F.J.; Duckles, S.P.

    1991-01-01

    The identity and distribution of muscarinic cholinergic receptor subtypes and associated signal transduction mechanisms was characterized for the cerebral circulation using correlated functional and biochemical investigations. Subtypes were distinguished by the relative affinities of a panel of muscarinic antagonists, pirenzepine, AF-DX 116 [11-2-[[2-[diethylaminomethyl]- 1-piperidinyl]acetyl]-5,11-dihydro-6H- pyrido[2,3-b][1,4]benzodiazepine-6-one], hexahydrosiladifenidol, methoctramine, 4-diphenylacetoxy-N-methylpiperidine methobromide, dicyclomine, para-fluoro-hexahydrosiladifenidol and atropine. Muscarinic receptors characterized by inhibition of [3H]quinuclidinylbenzilate binding in membranes of bovine pial arteries were of the M2 subtype. In contrast pharmacological analysis of [3H]-quinuclidinylbenzilate binding in bovine intracerebral microvessels suggests the presence of an M4 subtype. Receptors mediating endothelium-dependent vasodilation in rabbit pial arteries were of the M3 subtype, whereas muscarinic receptors stimulating endothelium-independent phosphoinositide hydrolysis in bovine pial arteries were of the M1 subtype. These findings suggest that characteristics of muscarinic receptors in cerebral blood vessels vary depending on the type of vessel, cellular location and function mediated

  18. An angiogenesis platform using a cubic artificial eggshell with patterned blood vessels on chicken chorioallantoic membrane.

    Science.gov (United States)

    Huang, Wenjing; Itayama, Makoto; Arai, Fumihito; Furukawa, Katsuko S; Ushida, Takashi; Kawahara, Tomohiro

    2017-01-01

    The chorioallantoic membrane (CAM) containing tiny blood vessels is an alternative to large animals for studies involving angiogenesis and tissue engineering. However, there is no technique to design the direction of growing blood vessels on the CAM at the microscale level for tissue engineering experiments. Here, a methodology is provided to direct blood vessel formation on the surface of a three-dimensional egg yolk using a cubic artificial eggshell with six functionalized membranes. A structure on the lateral side of the eggshell containing a straight channel and an interlinked chamber was designed, and the direction and formation area of blood vessels with blood flow was artfully defined by channels with widths of 70-2000 μm, without sharply reducing embryo viability. The relationship between the size of interlinked chamber and the induction of blood vessels was investigated to establish a theory of design. Role of negative and positive pressure in the induction of CAM with blood vessels was investigated, and air pressure change in the culture chamber was measured to demonstrate the mechanism for blood vessel induction. Histological evaluation showed that components of CAM including chorionic membrane and blood vessels were induced into the channels. Based on our design theory, blood vessels were induced into arrayed channels, and channel-specific injection and screening were realized, which demonstrated proposed applications. The platform with position- and space-controlled blood vessels is therefore a powerful tool for biomedical research, which may afford exciting applications in studies involved in local stimulation of blood vessel networks and those necessary to establish a living system with blood flow from a beating heart.

  19. 3D Near Infrared and Ultrasound Imaging of Peripheral Blood Vessels for Real-Time Localization and Needle Guidance.

    Science.gov (United States)

    Chen, Alvin I; Balter, Max L; Maguire, Timothy J; Yarmush, Martin L

    2016-10-01

    This paper presents a portable imaging device designed to detect peripheral blood vessels for cannula insertion that are otherwise difficult to visualize beneath the skin. The device combines near infrared stereo vision, ultrasound, and real-time image analysis to map the 3D structure of subcutaneous vessels. We show that the device can identify adult forearm vessels and be used to guide manual insertions in tissue phantoms with increased first-stick accuracy compared to unassisted cannulation. We also demonstrate that the system may be coupled with a robotic manipulator to perform automated, image-guided venipuncture.

  20. Vascular Patterns in Iguanas and Other Squamates: Blood Vessels and Sites of Thermal Exchange.

    Directory of Open Access Journals (Sweden)

    William Ruger Porter

    Full Text Available Squamates use the circulatory system to regulate body and head temperatures during both heating and cooling. The flexibility of this system, which possibly exceeds that of endotherms, offers a number of physiological mechanisms to gain or retain heat (e.g., increase peripheral blood flow and heart rate, cooling the head to prolong basking time for the body as well as to shed heat (modulate peripheral blood flow, expose sites of thermal exchange. Squamates also have the ability to establish and maintain the same head-to-body temperature differential that birds, crocodilians, and mammals demonstrate, but without a discrete rete or other vascular physiological device. Squamates offer important anatomical and phylogenetic evidence for the inference of the blood vessels of dinosaurs and other extinct archosaurs in that they shed light on the basal diapsid condition. Given this basal positioning, squamates likewise inform and constrain the range of physiological thermoregulatory mechanisms that may have been found in Dinosauria. Unfortunately, the literature on squamate vascular anatomy is limited. Cephalic vascular anatomy of green iguanas (Iguana iguana was investigated using a differential-contrast, dual-vascular injection (DCDVI technique and high-resolution X-ray microcomputed tomography (μCT. Blood vessels were digitally segmented to create a surface representation of vascular pathways. Known sites of thermal exchange, consisting of the oral, nasal, and orbital regions, were given special attention due to their role in brain and cephalic thermoregulation. Blood vessels to and from sites of thermal exchange were investigated to detect conserved vascular patterns and to assess their ability to deliver cooled blood to the dural venous sinuses. Arteries within sites of thermal exchange were found to deliver blood directly and through collateral pathways. The venous drainage was found to have multiple pathways that could influence neurosensory

  1. Vascular Patterns in Iguanas and Other Squamates: Blood Vessels and Sites of Thermal Exchange.

    Science.gov (United States)

    Porter, William Ruger; Witmer, Lawrence M

    2015-01-01

    Squamates use the circulatory system to regulate body and head temperatures during both heating and cooling. The flexibility of this system, which possibly exceeds that of endotherms, offers a number of physiological mechanisms to gain or retain heat (e.g., increase peripheral blood flow and heart rate, cooling the head to prolong basking time for the body) as well as to shed heat (modulate peripheral blood flow, expose sites of thermal exchange). Squamates also have the ability to establish and maintain the same head-to-body temperature differential that birds, crocodilians, and mammals demonstrate, but without a discrete rete or other vascular physiological device. Squamates offer important anatomical and phylogenetic evidence for the inference of the blood vessels of dinosaurs and other extinct archosaurs in that they shed light on the basal diapsid condition. Given this basal positioning, squamates likewise inform and constrain the range of physiological thermoregulatory mechanisms that may have been found in Dinosauria. Unfortunately, the literature on squamate vascular anatomy is limited. Cephalic vascular anatomy of green iguanas (Iguana iguana) was investigated using a differential-contrast, dual-vascular injection (DCDVI) technique and high-resolution X-ray microcomputed tomography (μCT). Blood vessels were digitally segmented to create a surface representation of vascular pathways. Known sites of thermal exchange, consisting of the oral, nasal, and orbital regions, were given special attention due to their role in brain and cephalic thermoregulation. Blood vessels to and from sites of thermal exchange were investigated to detect conserved vascular patterns and to assess their ability to deliver cooled blood to the dural venous sinuses. Arteries within sites of thermal exchange were found to deliver blood directly and through collateral pathways. The venous drainage was found to have multiple pathways that could influence neurosensory tissue temperature

  2. Blood Vessel Normalization in the Hamster Oral Cancer Model for Experimental Cancer Therapy Studies

    Energy Technology Data Exchange (ETDEWEB)

    Ana J. Molinari; Romina F. Aromando; Maria E. Itoiz; Marcela A. Garabalino; Andrea Monti Hughes; Elisa M. Heber; Emiliano C. C. Pozzi; David W. Nigg; Veronica A. Trivillin; Amanda E. Schwint

    2012-07-01

    Normalization of tumor blood vessels improves drug and oxygen delivery to cancer cells. The aim of this study was to develop a technique to normalize blood vessels in the hamster cheek pouch model of oral cancer. Materials and Methods: Tumor-bearing hamsters were treated with thalidomide and were compared with controls. Results: Twenty eight hours after treatment with thalidomide, the blood vessels of premalignant tissue observable in vivo became narrower and less tortuous than those of controls; Evans Blue Dye extravasation in tumor was significantly reduced (indicating a reduction in aberrant tumor vascular hyperpermeability that compromises blood flow), and tumor blood vessel morphology in histological sections, labeled for Factor VIII, revealed a significant reduction in compressive forces. These findings indicated blood vessel normalization with a window of 48 h. Conclusion: The technique developed herein has rendered the hamster oral cancer model amenable to research, with the potential benefit of vascular normalization in head and neck cancer therapy.

  3. Requirements on crack detection in pressurized vessels for ASME authorization

    International Nuclear Information System (INIS)

    Spremo, N.; Begovich, B.; Doko, A.

    1986-01-01

    The method is presented of training qualified personnel for nondestructive testing of pressure vessels. Personnel is divided according to experience and previous training into three groups of which each has its own educational programme. Written examinations in general knowledge and in specialized subjects and a practical examination in crack detection terminate the training. (E.S.). 1 fig., 4 tabs., 3 refs

  4. The vascular Ca2+-sensing receptor regulates blood vessel tone and blood pressure.

    Science.gov (United States)

    Schepelmann, M; Yarova, P L; Lopez-Fernandez, I; Davies, T S; Brennan, S C; Edwards, P J; Aggarwal, A; Graça, J; Rietdorf, K; Matchkov, V; Fenton, R A; Chang, W; Krssak, M; Stewart, A; Broadley, K J; Ward, D T; Price, S A; Edwards, D H; Kemp, P J; Riccardi, D

    2016-02-01

    The extracellular calcium-sensing receptor CaSR is expressed in blood vessels where its role is not completely understood. In this study, we tested the hypothesis that the CaSR expressed in vascular smooth muscle cells (VSMC) is directly involved in regulation of blood pressure and blood vessel tone. Mice with targeted CaSR gene ablation from vascular smooth muscle cells (VSMC) were generated by breeding exon 7 LoxP-CaSR mice with animals in which Cre recombinase is driven by a SM22α promoter (SM22α-Cre). Wire myography performed on Cre-negative [wild-type (WT)] and Cre-positive (SM22α)CaSR(Δflox/Δflox) [knockout (KO)] mice showed an endothelium-independent reduction in aorta and mesenteric artery contractility of KO compared with WT mice in response to KCl and to phenylephrine. Increasing extracellular calcium ion (Ca(2+)) concentrations (1-5 mM) evoked contraction in WT but only relaxation in KO aortas. Accordingly, diastolic and mean arterial blood pressures of KO animals were significantly reduced compared with WT, as measured by both tail cuff and radiotelemetry. This hypotension was mostly pronounced during the animals' active phase and was not rescued by either nitric oxide-synthase inhibition with nitro-l-arginine methyl ester or by a high-salt-supplemented diet. KO animals also exhibited cardiac remodeling, bradycardia, and reduced spontaneous activity in isolated hearts and cardiomyocyte-like cells. Our findings demonstrate a role for CaSR in the cardiovascular system and suggest that physiologically relevant changes in extracellular Ca(2+) concentrations could contribute to setting blood vessel tone levels and heart rate by directly acting on the cardiovascular CaSR.

  5. [Effects of high intensity focused ultrasound with SonoVue on blood vessels pathological examinations].

    Science.gov (United States)

    Qin, Yan; Bai, Jin; Li, Faqi; Wang, Zhibiao

    2010-12-01

    The injury of tumor blood vessels will break up the nutrition supply for the tumor. In this paper, we investigated the effects exerted by high intensity focused ultrasound (HIFU) combined with ultrasound microbubble agent on blood vessels. Ultrasound diagnosis was used to find the goat hepatic blood vessels each being approximately 3mm in diameter. HIFU was focused on the blood vessels. The acoustic power was 250W; HIFU irradiating Mode was line scan (the length of the line: 10 mm; speed: 3 mm/s; irradiating time: 30s). In the experimental group, 0.03 ml/kg SonoVue was injected into the goat before HIFU irradiation,while normal saline was given to the control group. The goats were killed at 24h after HIFU irradiation, then goat liver tissues and blood vessels of target area were taken out. HE staining and Victoria's blue and Ponceau's staining of tissue section showed that the endothelial cells of blood vessels dropped off and became necrosed, and the continuity of blood vessels was interrupted. HIFU combined with SonoVue will damage large blood vessels on HIFU focus, but there is no evident discrepancy between the group with SonoVue and the group without SonoVue.

  6. Determination of the critical buckling pressure of blood vessels using the energy approach.

    Science.gov (United States)

    Han, Hai-Chao

    2011-03-01

    The stability of blood vessels under lumen blood pressure is essential to the maintenance of normal vascular function. Differential buckling equations have been established recently for linear and nonlinear elastic artery models. However, the strain energy in bent buckling and the corresponding energy method have not been investigated for blood vessels under lumen pressure. The purpose of this study was to establish the energy equation for blood vessel buckling under internal pressure. A buckling equation was established to determine the critical pressure based on the potential energy. The critical pressures of blood vessels with small tapering along their axis were estimated using the energy approach. It was demonstrated that the energy approach yields both the same differential equation and critical pressure for cylindrical blood vessel buckling as obtained previously using the adjacent equilibrium approach. Tapering reduced the critical pressure of blood vessels compared to the cylindrical ones. This energy approach provides a useful tool for studying blood vessel buckling and will be useful in dealing with various imperfections of the vessel wall.

  7. Captopril improves tumor nanomedicine delivery by increasing tumor blood perfusion and enlarging endothelial gaps in tumor blood vessels.

    Science.gov (United States)

    Zhang, Bo; Jiang, Ting; Tuo, Yanyan; Jin, Kai; Luo, Zimiao; Shi, Wei; Mei, Heng; Hu, Yu; Pang, Zhiqing; Jiang, Xinguo

    2017-12-01

    Poor tumor perfusion and unfavorable vessel permeability compromise nanomedicine drug delivery to tumors. Captopril dilates blood vessels, reducing blood pressure clinically and bradykinin, as the downstream signaling moiety of captopril, is capable of dilating blood vessels and effectively increasing vessel permeability. The hypothesis behind this study was that captopril can dilate tumor blood vessels, improving tumor perfusion and simultaneously enlarge the endothelial gaps of tumor vessels, therefore enhancing nanomedicine drug delivery for tumor therapy. Using the U87 tumor xenograft with abundant blood vessels as the tumor model, tumor perfusion experiments were carried out using laser Doppler imaging and lectin-labeling experiments. A single treatment of captopril at a dose of 100 mg/kg significantly increased the percentage of functional vessels in tumor tissues and improved tumor blood perfusion. Scanning electron microscopy of tumor vessels also indicated that the endothelial gaps of tumor vessels were enlarged after captopril treatment. Immunofluorescence-staining of tumor slices demonstrated that captopril significantly increased bradykinin expression, possibly explaining tumor perfusion improvements and endothelial gap enlargement. Additionally, imaging in vivo, imaging ex vivo and nanoparticle distribution in tumor slices indicated that after a single treatment with captopril, the accumulation of 115-nm nanoparticles in tumors had increased 2.81-fold with a more homogeneous distribution pattern in comparison to non-captopril treated controls. Finally, pharmacodynamics experiments demonstrated that captopril combined with paclitaxel-loaded nanoparticles resulted in the greatest tumor shrinkage and the most extensive necrosis in tumor tissues among all treatment groups. Taken together, the data from the present study suggest a novel strategy for improving tumor perfusion and enlarging blood vessel permeability simultaneously in order to improve

  8. Three-dimensional reconstruction of rat dermal blood vessels in vivo

    Science.gov (United States)

    Barton, Jennifer K.; Izatt, Joseph A.; Kulkarni, Manish D.; Welch, Ashley J.

    1997-05-01

    We performed imaging and reconstruction of dermal and subdermal blood vessels in a rat skin flap window model. The window model consists of a double thickness of dorsal skin which is sutured to a holding fixture. A 1 cm circle of skin is removed from one thickness, exposing the dermal blood vessels of the opposing side. An optical coherence tomography system operating at 1310 nm was used to image the blood vessels. A series of transverse images of the window model characterized sections of tissue. Off-the-shelf software for desktop and workstation computers was used to preprocess the images, identify and reconstruct blood vessels, and to extract parameters such depth, diameter, and percent volume of blood vessels. Such parameters may be of interest in developing improved treatments for vascular disorders such as port wine stains.

  9. A Morphological Hessian Based Approach for Retinal Blood Vessels Segmentation and Denoising Using Region Based Otsu Thresholding

    Science.gov (United States)

    BahadarKhan, Khan; A Khaliq, Amir; Shahid, Muhammad

    2016-01-01

    Diabetic Retinopathy (DR) harm retinal blood vessels in the eye causing visual deficiency. The appearance and structure of blood vessels in retinal images play an essential part in the diagnoses of an eye sicknesses. We proposed a less computational unsupervised automated technique with promising results for detection of retinal vasculature by using morphological hessian based approach and region based Otsu thresholding. Contrast Limited Adaptive Histogram Equalization (CLAHE) and morphological filters have been used for enhancement and to remove low frequency noise or geometrical objects, respectively. The hessian matrix and eigenvalues approach used has been in a modified form at two different scales to extract wide and thin vessel enhanced images separately. Otsu thresholding has been further applied in a novel way to classify vessel and non-vessel pixels from both enhanced images. Finally, postprocessing steps has been used to eliminate the unwanted region/segment, non-vessel pixels, disease abnormalities and noise, to obtain a final segmented image. The proposed technique has been analyzed on the openly accessible DRIVE (Digital Retinal Images for Vessel Extraction) and STARE (STructured Analysis of the REtina) databases along with the ground truth data that has been precisely marked by the experts. PMID:27441646

  10. A Morphological Hessian Based Approach for Retinal Blood Vessels Segmentation and Denoising Using Region Based Otsu Thresholding.

    Directory of Open Access Journals (Sweden)

    Khan BahadarKhan

    Full Text Available Diabetic Retinopathy (DR harm retinal blood vessels in the eye causing visual deficiency. The appearance and structure of blood vessels in retinal images play an essential part in the diagnoses of an eye sicknesses. We proposed a less computational unsupervised automated technique with promising results for detection of retinal vasculature by using morphological hessian based approach and region based Otsu thresholding. Contrast Limited Adaptive Histogram Equalization (CLAHE and morphological filters have been used for enhancement and to remove low frequency noise or geometrical objects, respectively. The hessian matrix and eigenvalues approach used has been in a modified form at two different scales to extract wide and thin vessel enhanced images separately. Otsu thresholding has been further applied in a novel way to classify vessel and non-vessel pixels from both enhanced images. Finally, postprocessing steps has been used to eliminate the unwanted region/segment, non-vessel pixels, disease abnormalities and noise, to obtain a final segmented image. The proposed technique has been analyzed on the openly accessible DRIVE (Digital Retinal Images for Vessel Extraction and STARE (STructured Analysis of the REtina databases along with the ground truth data that has been precisely marked by the experts.

  11. Effects of shear forces and pressure on blood vessel function and metabolism in a perfusion bioreactor.

    Science.gov (United States)

    Hoenicka, Markus; Wiedemann, Ludwig; Puehler, Thomas; Hirt, Stephan; Birnbaum, Dietrich E; Schmid, Christof

    2010-12-01

    Bovine saphenous veins (BSV) were incubated in a perfusion bioreactor to study vessel wall metabolism and wall structure under tissue engineering conditions. Group 1 vessels were perfused for 4 or 8 days. The viscosity of the medium was increased to that of blood in group 2. Group 3 vessels were additionally strained with luminal pressure. Groups 1-d through 3-d were similar except that BSV were endothelium-denuded before perfusion. Groups 1-a through 3-a used native vessels at elevated flow rates. Group 3 vessels responded significantly better to noradrenaline on day 4, whereas denuded vessels showed attenuated responses (p vessels. pO₂ gradients across the vessels were independent of time and significantly higher in group 2 (p vessels of groups 3, 1-d, and 3-d which released more lactate than glucose could supply (p vessels as well as all vessels perfused with elevated flow rates showed a loss of endothelial cells after 4 days, whereas group 2 and 3 vessels retained most of the endothelium. These data suggest that vessel metabolism was not limited by oxygen supply. Shear forces did not affect glucose metabolism but increased oxygen consumption and endothelial cell survival. Luminal pressure caused the utilization of energy sources other than glucose, as long as the endothelium was intact. Therefore, vessel metabolism needs to be monitored during tissue engineering procedures which challenge the constructs with mechanical stimuli.

  12. Mammalian Cardiovascular Patterning as Determined by Hemodynamic Forces and Blood Vessel Genetics

    Science.gov (United States)

    Anderson, Gregory Arthur

    Cardiovascular development is a process that involves the timing of multiple molecular events, and numerous subtle three-dimensional conformational changes. Traditional developmental biology techniques have provided large quantities of information as to how these complex organ systems develop. However, the major drawback of the majority of current developmental biological imaging is that they are two-dimensional in nature. It is now well recognized that circulation of blood is required for normal patterning and remodeling of blood vessels. Normal blood vessel formation is dependent upon a complex network of signaling pathways, and genetic mutations in these pathways leads to impaired vascular development, heart failure, and lethality. As such, it is not surprising that mutant mice with aberrant cardiovascular patterning are so common, since normal development requires proper coordination between three systems: the heart, the blood, and the vasculature. This thesis describes the implementation of a three-dimensional imaging technique, optical projection tomography (OPT), in conjunction with a computer-based registration algorithm to statistically analyze developmental differences in groups of wild-type mouse embryos. Embryos that differ by only a few hours' gestational time are shown to have developmental differences in blood vessel formation and heart development progression that can be discerned. This thesis describes how we analyzed mouse models of cardiovascular perturbation by OPT to detect morphological differences in embryonic development in both qualitative and quantitative ways. Both a blood vessel specific mutation and a cardiac specific mutation were analyzed, providing evidence that developmental defects of these types can be quantified. Finally, we describe the implementation of OPT imaging to identify statistically significant phenotypes from three different mouse models of cardiovascular perturbation across a range of developmental time points. Image

  13. Primo Vascular System Accompanying a Blood Vessel from Tumor Tissue and a Method to Distinguish It from the Blood or the Lymph System

    Directory of Open Access Journals (Sweden)

    Jaekwan Lim

    2013-01-01

    Full Text Available A primo vessel was observed in the abdominal cavity in the lung cancer mouse model, and its function as an extra metastatic path was observed. In this work, we found a primo vessel accompanying a blood vessel emanating from a tumor in the skin. We also presented simple and efficient criteria to distinguish a primo vessel from a blood or a lymph vessel and from a nerve. The criteria for using DAPI and Phalloidin will be useful in clinical situations to find and identify the primo vessels among the blood vessels, lymph vessels, or nerves in the tissue surrounding a tumor such as a melanoma or breast cancer.

  14. Low cost labeling with highlighter ink efficiently visualizes developing blood vessels in avian and mouse embryos.

    Science.gov (United States)

    Takase, Yuta; Tadokoro, Ryosuke; Takahashi, Yoshiko

    2013-12-01

    To understand how blood vessels form to establish the intricate network during vertebrate development, it is helpful if one can visualize the vasculature in embryos. We here describe a novel labeling method using highlighter ink, easily obtained in stationery stores with a low cost, to visualize embryo-wide vasculatures in avian and mice. We tested 50 different highlighters for fluorescent microscopy with filter sets equipped in a standard fluorescent microscope. The yellow and violet inks yielded fluorescent signals specifically detected by the filters used for green fluorescent protein (GFP) and red fluorescent protein (RFP) detections, respectively. When the ink solution was infused into chicken/quail and mouse embryos, vasculatures including large vessels and capillaries were labeled both in living and fixed embryos. Ink-infused embryos were further subjected to histological sections, and double stained with antibodies including QH-1 (quail), α smooth muscle actin (αSMA), and PECAM-1 (mouse), revealing that the endothelial cells were specifically labeled by the infused highlighter ink. Highlighter-labeled signals were detected with a resolution comparable to or higher than signals of fluorescein isothiocyanate (FITC)-lectin and Rhodamine-dextran, conventionally used for angiography. Furthermore, macroconfocal microscopic analyses with ink-infused embryos visualized fine vascular structures of both embryo proper and extra-embryonic plexus in a Z-stack image of 2400 μm thick with a markedly high resolution. Together, the low cost highlighter ink serves as an alternative reagent useful for visualization of blood vessels in developing avian and mouse embryos and possibly in other animals. © 2013 The Authors Development, Growth & Differentiation © 2013 Japanese Society of Developmental Biologists.

  15. Effect of non-Newtonian characteristics of blood on magnetic particle capture in occluded blood vessel

    Energy Technology Data Exchange (ETDEWEB)

    Bose, Sayan; Banerjee, Moloy, E-mail: moloy_kb@yahoo.com

    2015-01-15

    Magnetic nanoparticles drug carriers continue to attract considerable interest for drug targeting in the treatment of cancer and other pathological conditions. Magnetic carrier particles with surface-bound drug molecules are injected into the vascular system upstream from the desired target site, and are captured at the target site via a local applied magnetic field. Herein, a numerical investigation of steady magnetic drug targeting (MDT) using functionalized magnetic micro-spheres in partly occluded blood vessel having a 90° bent is presented considering the effects of non-Newtonian characteristics of blood. An Eulerian–Lagrangian technique is adopted to resolve the hemodynamic flow and the motion of the magnetic particles in the flow using ANSYS FLUENT. An implantable infinitely long cylindrical current carrying conductor is used to create the requisite magnetic field. Targeted transport of the magnetic particles in a partly occluded vessel differs distinctly from the same in a regular unblocked vessel. Parametric investigation is conducted and the influence of the insert configuration and its position from the central plane of the artery (z{sub offset}), particle size (d{sub p}) and its magnetic property (χ) and the magnitude of current (I) on the “capture efficiency” (CE) is reported. Analysis shows that there exists an optimum regime of operating parameters for which deposition of the drug carrying magnetic particles in a target zone on the partly occluded vessel wall can be maximized. The results provide useful design bases for in vitro set up for the investigation of MDT in stenosed blood vessels. - Highlights: • Two counter rotating vortices forces the fluid flow back through the more viscous region. • The existence of strong recirculation zone just downstream side of the occlusion. • Configuration 4 produces the better efficient MDT system. • Modified Casson model predicts the highest value of CE, whereas the generalized power law gives

  16. Estimation of vessel diameter and blood flow dynamics from laser speckle images

    DEFF Research Database (Denmark)

    Postnov, Dmitry D.; Tuchin, Valery V.; Sosnovtseva, Olga

    2016-01-01

    Laser speckle imaging is a rapidly developing method to study changes of blood velocity in the vascular networks. However, to assess blood flow and vascular responses it is crucial to measure vessel diameter in addition to blood velocity dynamics. We suggest an algorithm that allows for dynamical...... masking of a vessel position and measurements of it's diameter from laser speckle images. This approach demonstrates high reliability and stability....

  17. An Original Approach for Quantification of Blood Vessels on the Whole Tumour Section

    Directory of Open Access Journals (Sweden)

    Nga Tran Kim

    2003-01-01

    Full Text Available Relative abundance of tumour angiogenesis has been shown to be of clinical relevance in cancers of various locations such as the ovary. Nevertheless, several problems are encountered when quantifying tumour microvessels: (i as many other tumour markers, vascularity pattern is often heterogeneous within the tumour mass and even within the same histological section. As a consequence, an adequate acquisition method must be developed for accurate field sampling. (ii Manual microvessel counting is long, tedious and subject to poor reproducibility. Introduction in routine practice requires a fast, reproducible and reliable automatic image processing. In this study we present an original procedure combining a slide scanner image acquisition and a fully automatic image analysis sequence. The slide scanner offers the advantage of recording an image of the whole histological section for subsequent automatic blood vessel detection and hot spot area location. Microvessel density and surface fraction were measured for the whole section as well as within hot spots. Different immunostaining methods were tested in order to optimise the procedure. Moreover, the method proposed was submitted to a quality control procedure, with reference to interactive identification of microvessels at scanner level. This experiment showed that 93 to 97% of blood vessels were detected, according to the staining protocol used. Colour figures can be viewed on http://www.esacp.org/acp/2003/25‐2/kim.htm.

  18. Investigating laser/blood-vessel interaction with color Doppler optical coherence tomography

    Science.gov (United States)

    Barton, Jennifer K.; Izatt, Joseph A.; Welch, Ashley J.

    1998-04-01

    A non-invasive method of imaging laser irradiated blood vessels, and of tracking the healing response, has been achieved using Color Doppler Optical Coherence Tomography (CDOCT). This method may increase understanding of the mechanisms behind treatment of vascular disorders such as port wine stains. The CDOCT system uses a superluminescent diode with a center wavelength of 1280 nm. Pulsed dye and KTP lasers operating at 585 and 532 nm, respectively, were used to irradiate rat and hamster dorsal skin flap window models. The window model is a chronic preparation which exposes subdermal blood vessels while maintaining a thickness of normal skin. Irradiation sites were imaged with CDOCT prior to and immediately after laser irradiation, and at intervals up to several days following irradiation. The CDOCT signal was processed to provide both magnitude and color Doppler images. The Doppler signal provides an estimate of the blood flow velocity. The response of blood vessels to radiant exposures above and below the threshold for vessel coagulation was measured. An increase in the blood vessel backscattered signal was observed as blood and vessel walls were coagulated. Changes in blood flow velocity were noted in cases where vessels constricted or flow became occluded.

  19. Nerves are more abundant than blood vessels in the degenerate human intervertebral disc.

    Science.gov (United States)

    Binch, Abbie L A; Cole, Ashley A; Breakwell, Lee M; Michael, Antony L R; Chiverton, Neil; Creemers, Laura B; Cross, Alison K; Le Maitre, Christine L

    2015-12-21

    Chronic low back pain (LBP) is the most common cause of disability worldwide. New ideas surrounding LBP are emerging that are based on interactions between mechanical, biological and chemical influences on the human IVD. The degenerate IVD is proposed to be innervated by sensory nerve fibres and vascularised by blood vessels, and it is speculated to contribute to pain sensation. However, the incidence of nerve and blood vessel ingrowth, as well as whether these features are always associated, is unknown. We investigated the presence of nerves and blood vessels in the nucleus pulposus (NP) of the IVD in a large population of human discs. Immunohistochemistry was performed with 61 human IVD samples, to identify and localise nerves (neurofilament 200 [NF200]/protein gene product 9.5) and blood vessels (CD31) within different regions of the IVD. Immunopositivity for NF200 was identified within all regions of the IVD within post-mortem tissues. Nerves were seen to protrude across lamellar ridges and through matrix towards NP cells. Nerves were identified deep within the NP and were in many cases, but not always, seen in close proximity to fissures or in areas where decreased matrix was seen. Fifteen percent of samples were degenerate and negative for nerves and blood vessels, whilst 16 % of all samples were degenerate with nerves and blood vessels. We identified 52% of samples that were degenerate with nerves but no blood vessels. Interestingly, only 4% of all samples were degenerate with no nerves but positive for blood vessels. Of the 85 samples investigated, only 6 % of samples were non-degenerate without nerves and blood vessels and 7% had nerves but no blood vessels. This study addresses the controversial topic of nerve and blood vessel ingrowth into the IVD in a large number of human samples. Our findings demonstrate that nerves are present within a large proportion of NP samples from degenerate IVDs. This study shows a possible link between nerve ingrowth and

  20. Solitonlike attractor for blood vessel tip density in angiogenesis

    Science.gov (United States)

    Bonilla, L. L.; Carretero, M.; Terragni, F.

    2016-12-01

    Recently, numerical simulations of a stochastic model have shown that the density of vessel tips in tumor-induced angiogenesis adopts a solitonlike profile [Sci. Rep. 6, 31296 (2016), 10.1038/srep31296]. In this work, we derive and solve the equations for the soliton collective coordinates that indicate how the soliton adapts its shape and velocity to varying chemotaxis and diffusion. The vessel tip density can be reconstructed from the soliton formulas. While the stochastic model exhibits large fluctuations, we show that the location of the maximum vessel tip density for different replicas follows closely the soliton peak position calculated either by ensemble averages or by solving an alternative deterministic description of the density. The simple soliton collective coordinate equations may also be used to ascertain the response of the vessel network to changes in the parameters and thus to control it.

  1. A functional requirement for astroglia in promoting blood vessel development in the early postnatal brain.

    Science.gov (United States)

    Ma, Shang; Kwon, Hyo Jun; Huang, Zhen

    2012-01-01

    Astroglia are a major cell type in the brain and play a key role in many aspects of brain development and function. In the adult brain, astrocytes are known to intimately ensheath blood vessels and actively coordinate local neural activity and blood flow. During development of the neural retina, blood vessel growth follows a meshwork of astrocytic processes. Several genes have also been implicated in retinal astrocytes for regulating vessel development. This suggests a role of astrocytes in promoting angiogenesis throughout the central nervous system. To determine the roles that astrocytes may play during brain angiogenesis, we employ genetic approaches to inhibit astrogliogenesis during perinatal corticogenesis and examine its effects on brain vessel development. We find that conditional deletion from glial progenitors of orc3, a gene required for DNA replication, dramatically reduces glial progenitor cell number in the subventricular zone and astrocytes in the early postnatal cerebral cortex. This, in turn, results in severe reductions in both the density and branching frequency of cortical blood vessels. Consistent with a delayed growth but not regression of vessels, we find neither significant net decreases in vessel density between different stages after normalizing for cortical expansion nor obvious apoptosis of endothelial cells in these mutants. Furthermore, concomitant with loss of astroglial interactions, we find increased endothelial cell proliferation, enlarged vessel luminal size as well as enhanced cytoskeletal gene expression in pericytes, which suggests compensatory changes in vascular cells. Lastly, we find that blood vessel morphology in mutant cortices recovers substantially at later stages, following astrogliosis. These results thus implicate a functional requirement for astroglia in promoting blood vessel growth during brain development.

  2. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  3. Vessel and oil spill early detection using COSMO satellite imagery

    Science.gov (United States)

    Revollo, Natalia V.; Delrieux, Claudio A.

    2017-10-01

    Oil spillage is one of the most common sources of environmental damage in places where coastal wild life is found in natural reservoirs. This is especially the case in the Patagonian coast, with a littoral more than 5000 km long and a surface above a million and half square km. In addition, furtive fishery activities in Argentine waters are depleting the food supplies of several species, altering the ecological equilibrium. For this reason, early oil spills and vessel detection is an imperative surveillance task for environmental and governmental authorities. However, given the huge geographical extension, human assisted monitoring is unfeasible, and therefore real time remote sensing technologies are the only operative and economically feasible solution. In this work we describe the theoretical foundations and implementation details of a system specifically designed to take advantage of the SAR imagery delivered by two satellite constellations (the SAOCOM mission, developed by the Argentine Space Agency, and the COSMO mission, developed by the Italian Space Agency), to provide real-time detection of vessels and oil spills. The core of the system is based on pattern recognition over a statistical characterization of the texture patterns arising in the positive and negative conditions (i.e., vessel, oil, or plain sea surfaces). Training patterns were collected from a large number of previously reported contacts tagged by experts in the National Commission on Space Activities (CONAE). The resulting system performs well above the sensitivity and specificity of other avalilable systems.

  4. Peptide-Mediated Liposomal Drug Delivery System Targeting Tumor Blood Vessels in Anticancer Therapy

    Directory of Open Access Journals (Sweden)

    Han-Chung Wu

    2010-01-01

    Full Text Available Solid tumors are known to recruit new blood vessels to support their growth. Therefore, unique molecules expressed on tumor endothelial cells can function as targets for the antiangiogenic therapy of cancer. Current efforts are focusing on developing therapeutic agents capable of specifically targeting cancer cells and tumor-associated microenvironments including tumor blood vessels. These therapies hold the promise of high efficacy and low toxicity. One recognized strategy for improving the therapeutic effectiveness of conventional chemotherapeutics is to encapsulate anticancer drugs into targeting liposomes that bind to the cell surface receptors expressed on tumor-associated endothelial cells. These anti-angiogenic drug delivery systems could be used to target both tumor blood vessels as well as the tumor cells, themselves. This article reviews the mechanisms and advantages of various present and potential methods using peptide-conjugated liposomes to specifically destroy tumor blood vessels in anticancer therapy.

  5. Blood vessel growth blocker may treat AIDS-related Kaposi’s sarcoma

    Science.gov (United States)

    Patients with an AIDS-associated cancer, Kaposi's sarcoma (KS), showed improvement after receiving the combination of bevacizumab, a cancer drug that blocks the growth of new blood vessels, and highly active antiretroviral therapy (HAART).

  6. Effect of electrical stimulation on blood flow velocity and vessel size

    Directory of Open Access Journals (Sweden)

    Jin Hee-Kyung

    2017-03-01

    Full Text Available Interferential current electrical stimulation alters blood flow velocity and vessel size. We aimed to investigate the changes in the autonomic nervous system depending on electrical stimulation parameters.

  7. Engineering a Blood Vessel Network Module for Body-on-a-Chip Applications.

    Science.gov (United States)

    Ryu, Hyunryul; Oh, Soojung; Lee, Hyun Jae; Lee, Jin Young; Lee, Hae Kwang; Jeon, Noo Li

    2015-06-01

    The blood circulatory system links all organs from one to another to support and maintain each organ's functions consistently. Therefore, blood vessels have been considered as a vital unit. Engineering perfusable functional blood vessels in vitro has been challenging due to difficulties in designing the connection between rigid macroscale tubes and fragile microscale ones. Here, we propose a generalizable method to engineer a "long" perfusable blood vessel network. To form millimeter-scale vessels, fibroblasts were co-cultured with human umbilical vein endothelial cells (HUVECs) in close proximity. In contrast to previous works, in which all cells were permanently placed within the device, we developed a novel method to culture paracrine factor secreting fibroblasts on an O-ring-shaped guide that can be transferred in and out. This approach affords flexibility in co-culture, where the effects of secreted factors can be decoupled. Using this, blood vessels with length up to 2 mm were successfully produced in a reproducible manner (>90%). Because the vessels form a perfusable network within the channel, simple links to inlets and outlets of the device allowed connections to the outside world. The robust and reproducible formation of in vitro engineered vessels can be used as a module to link various organ components as parts of future body-on-a-chip applications. © 2014 Society for Laboratory Automation and Screening.

  8. Temperature evolution in tissues embedded with large blood vessels during photo-thermal heating.

    Science.gov (United States)

    Paul, Anup; Narasimhan, Arunn; Kahlen, Franz J; Das, Sarit K

    2014-04-01

    During laser-assisted photo-thermal therapy, the temperature of the heated tissue region must rise to the therapeutic value (e.g., 43°C) for complete ablation of the target cells. Large blood vessels (larger than 500 micron in diameter) at or near the irradiated tissues have a considerable impact on the transient temperature distribution in the tissue. In this study, the cooling effects of large blood vessels on temperature distribution in tissues during laser irradiation are predicted using finite element based simulation. A uniform flow is assumed at the entrance and three-dimensional conjugate heat transfer equations in the tissue region and the blood region are simultaneously solved for different vascular models. A volumetric heat source term based on Beer-Lambert law is introduced into the energy equation to account for laser heating. The heating pattern is taken to depend on the absorption and scattering coefficients of the tissue medium. Experiments are also conducted on tissue mimics in the presence and absence of simulated blood vessels to validate the numerical model. The coupled heat transfer between thermally significant blood vessels and their surrounding tissue for three different tissue-vascular networks are analyzed keeping the laser irradiation constant. A surface temperature map is obtained for different vascular models and for the bare tissue (without blood vessels). The transient temperature distribution is seen to differ according to the nature of the vascular network, blood vessel size, flow rate, laser spot size, laser power and tissue blood perfusion rate. The simulations suggest that the blood flow through large blood vessels in the vicinity of the photothermally heated tissue can lead to inefficient heating of the target. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Superficial and deep blood vessel distribution in the frog telencephalon. Reference to morphological brain asymmetries.

    Science.gov (United States)

    Kemali, M; Sada, E; Fiorino, L

    1990-01-01

    Nine frogs of the species "Rana esculenta" were heart perfused with Microfile Silicone Rubber. The frogs were examined both after dissection (cut with a razor blade) to study the superficial blood vessel pattern, and histologically (the Nissl staining method) to study the distribution of the deep blood capillaries. While the superficial blood vary in pattern, the deep capillaries are distributed symmetrically. This finding does not support a correlation between blood vessel pattern and morphological brain asymmetry, at least in the frog, and thus other explanations must be sought to explain brain asymmetry.

  10. Differential Effects between Cigarette Total Particulate Matter and Cigarette Smoke Extract on Blood and Blood Vessel

    Science.gov (United States)

    Park, Jung-Min; Chang, Kyung-Hwa; Park, Kwang-Hoon; Choi, Seong-Jin; Lee, Kyuhong; Lee, Jin-Yong; Satoh, Masahiko; Song, Seong-Yu; Lee, Moo-Yeol

    2016-01-01

    The generation and collection of cigarette smoke (CS) is a prerequisite for any toxicology study on smoking, especially an in vitro CS exposure study. In this study, the effects on blood and vascular function were tested with two widely used CS preparations to compare the biological effects of CS with respect to the CS preparation used. CS was prepared in the form of total particulate matter (TPM), which is CS trapped in a Cambridge filter pad, and cigarette smoke extract (CSE), which is CS trapped in phosphate-buffered saline. TPM potentiated platelet reactivity to thrombin and thus increased aggregation at a concentration of 25~100 μg/mL, whereas 2.5~10% CSE decreased platelet aggregation by thrombin. Both TPM and CSE inhibited vascular contraction by phenylephrine at 50~100 μg/mL and 10%, respectively. TPM inhibited acetylcholine-induced vasorelaxation at 10~100 μg/mL, but CSE exhibited a minimal effect on relaxation at the concentration that affects vasoconstriction. Neither TPM nor CSE induced hemolysis of erythrocytes or influenced plasma coagulation, as assessed by prothrombin time (PT) and activated partial thromboplastin time (aPTT). Taken together, CS affects platelet activity and deteriorates vasomotor functions in vitro. However, the effect on blood and blood vessels may vary depending on the CS preparation. Therefore, the results of experiments conducted with CS preparations should be interpreted with caution. PMID:27818738

  11. Growth and Remodeling in Blood Vessels Studied In Vivo With Fractal Analysis

    Science.gov (United States)

    Parsons-Wingerter, Patricia A.

    2003-01-01

    Every cell in the human body must reside in close proximity to a blood vessel (within approximately 200 mm) because blood vessels provide the oxygen, metabolite, and fluid exchanges required for cellular existence. The growth and remodeling of blood vessels are required to support the normal physiology of embryonic development, reproductive biology, wound healing and adaptive remodeling to exercise, as well as abnormal tissue change in diseases such as cancer, diabetes, and coronary heart disease. Cardiovascular and hemodynamic (blood flow dynamics) alterations experienced by astronauts during long-term spaceflight, including orthostatic intolerance, fluid shifts in the body, and reduced numbers of red (erythrocyte) and white (immune) blood cells, are identified as risk factors of very high priority in the NASA task force report on risk reduction for human spaceflight, the "Critical Path Roadmap."

  12. Effect of the Blood Vessel Viscoelasticity on Periodic Blood Pressure Wave Propagation

    Science.gov (United States)

    Kitawaki, Tomoki; Shimizu, Masashi

    Clinical arterial stiffness indexes such as PWV (pulse wave velocity) or PP (pulse pressure), which are obtained by analyzing blood pressure pulse waveforms in vivo, are used in the prognosis of cardiovascular diseases and thus analyses of pulse waveform are clinically important. The pulse wave in vivo, however, is complicated because of the complex viscoelastic property of the blood vessel wall. In addition, numerical flow simulations are useful for understanding pulse wave propagation in circulatory systems. Our proposed nonlinear one-dimensional numerical simulation model can accurately simulate the measurements of pressure waves in a silicone rubber tube and indicate that the viscoelasticity of the tube wall was significantly influenced by a single pulse waveform; however, the influence of viscoelasticity change on periodic pulsatile wave propagation has not yet been studied. The purpose of this study was therefore to investigate the effect of viscoelasticity change on the periodic pulsatile wave. For this purpose, we examined the effect of the viscoelasticity of a single silicone tube on periodic pulse wave propagation by comparing the calculated results using a one-dimensional model. As a result, the one-dimensional model could accurately express the experimental results with periodic pulsatile waves. In addition, both PWV and PP increase when the viscoelastic value of the dynamic modulus elasticity ratio increases, because increasing the elastic modulus is more effective than the energy dissipation effect by viscoelasticity change. Consequently, it is necessary to measure the viscoelastic property of the vessel wall accurately in order to estimate the arterial stiffness index (PWV and PP) accurately.

  13. Laser photothermolysis of single blood vessels in the chick chorioallantoic membrane (CAM)

    Science.gov (United States)

    Kimel, Sol; Svaasand, Lars O.; Milner, Thomas E.; Hammer-Wilson, Marie J.; Schell, Michael J.; Nelson, J. Stuart; Berns, Michael W.

    1994-02-01

    Individual blood vessels in the chick chorioallantoic membrane (CAM) were selectively coagulated through photothermolysis, using pulsed laser irradiation at 585 nm. Pulse durations were chosen to be 0.45 ms and 10 ms, which correspond to the thermal relaxation times in blood vessels of 30 micrometers and 150 micrometers diameter, respectively. The dose vs diameter (D vs d) relationship for coagulation was calculated for the two pulse shapes. The energy deposited in a cylindrical absorber of diameter d by an optical field, incident perpendicular to the vessel, was expressed analytically and compared with the energy required to coagulate a blood vessel of the same lumen diameter. When thermal diffusion is incorporated into the model, our findings can be accounted for quantitatively. This information will be of use for improving the laser treatment of port wine stains and other vasculopathies.

  14. Conduit vessel blood flow during the trek to Mount Everest base camp.

    Science.gov (United States)

    Dumais, Valerie; Nault, Patrice; Tsertsvadze, Alexander; Forbes, Thomas L

    2011-12-01

    Hemodynamic changes in response to the hypoxic environment of high altitude are vascular bed-specific. The aim of the present study was to investigate diameter and blood flow changes in conduit vessels in response to hypobaric hypoxia. Eleven healthy subjects ascending Mount Everest to base camp participated in this study. Vessel diameter and blood velocity for brachial, carotid, common femoral, superficial femoral, and deep femoral arteries were measured by portable Doppler ultrasound. Blood flow was calculated from these values. Measurements were taken at sea level, at increasing altitudes on ascent to base camp (1310 m, 3470 m, 5330 m), and repeated on descent to lower altitude (1310 m). For all vessels except carotids, both vessel diameter and blood flow decreased between sea level and initial ascent to altitude, with subsequent persistence of these decreased values; there was no further significant change with continued ascent to higher altitude. Blood flow for all arteries (except carotids) increased significantly on descent to lower altitude, with an associated nonsignificant increase in velocity and decrease in diameter. This study showed that there is vasoconstriction of limb conduit vessels at altitude, which persists upon descent to lower altitude. Blood flow in these vessels also decreases with initial exposure to high altitude, yet increases when returning to lower altitude, reflecting variations in blood velocity. Carotid arteries responded differently to the stimulus of hypobaria than limb conduit vessels; there was no change in diameter seen on ascent or descent, but there was a progressive decrease in blood flow on ascent, with no change on subsequent descent. Copyright © 2011 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  15. Blood pressure gradients in cerebral arteries: a clue to pathogenesis of cerebral small vessel disease.

    Science.gov (United States)

    Blanco, Pablo J; Müller, Lucas O; Spence, J David

    2017-09-01

    The role of hypertension in cerebral small vessel disease is poorly understood. At the base of the brain (the 'vascular centrencephalon'), short straight arteries transmit blood pressure directly to small resistance vessels; the cerebral convexity is supplied by long arteries with many branches, resulting in a drop in blood pressure. Hypertensive small vessel disease (lipohyalinosis) causes the classically described lacunar infarctions at the base of the brain; however, periventricular white matter intensities (WMIs) seen on MRI and WMI in subcortical areas over the convexity, which are often also called 'lacunes', probably have different aetiologies. We studied pressure gradients from proximal to distal regions of the cerebral vasculature by mathematical modelling. Blood flow/pressure equations were solved in an Anatomically Detailed Arterial Network (ADAN) model, considering a normotensive and a hypertensive case. Model parameters were suitably modified to account for structural changes in arterial vessels in the hypertensive scenario. Computations predict a marked drop in blood pressure from large and medium-sized cerebral vessels to cerebral peripheral beds. When blood pressure in the brachial artery is 192/113 mm Hg, the pressure in the small arterioles of the posterior parietal artery bed would be only 117/68 mm Hg. In the normotensive case, with blood pressure in the brachial artery of 117/75 mm Hg, the pressure in small parietal arterioles would be only 59/38 mm Hg. These findings have important implications for understanding small vessel disease. The marked pressure gradient across cerebral arteries should be taken into account when evaluating the pathogenesis of small WMIs on MRI. Hypertensive small vessel disease, affecting the arterioles at the base of the brain should be distinguished from small vessel disease in subcortical regions of the convexity and venous disease in the periventricular white matter.

  16. A rigid disc for protection of exposed blood vessels during negative pressure wound therapy.

    Science.gov (United States)

    Anesäter, Erik; Borgquist, Ola; Torbrand, Christian; Roupé, K Markus; Ingemansson, Richard; Lindstedt, Sandra; Malmsjö, Malin

    2013-02-01

    There are increasing reports of serious complications and deaths associated with negative pressure wound therapy (NPWT). Bleeding may occur when NPWT is applied to a wound with exposed blood vessels. Inserting a rigid disc in the wound may protect these structures. The authors examined the effects of rigid discs on wound bed tissue pressure and blood flow through a large blood vessel in the wound bed during NPWT. Wounds were created over the femoral artery in the groin of 8 pigs. Rigid discs were inserted. Wound bed pressures and arterial blood flow were measured during NPWT. Pressure transduction to the wound bed was similar for control wounds and wounds with discs. Blood flow through the femoral artery decreased in control wounds. When a disc was inserted, the blood flow was restored. NPWT causes hypoperfusion in the wound bed tissue, presumably as a result of mechanical deformation. The insertion of a rigid barrier alleviates this effect and restores blood flow.

  17. Vasodilator effects of ibudilast on retinal blood vessels in anesthetized rats.

    Science.gov (United States)

    Noguchi, Masahiro; Mori, Asami; Sakamoto, Kenji; Nakahara, Tsutomu; Ishii, Kunio

    2009-11-01

    Ibudilast (3-isobutyryl-2-isopropylpyrazolo[1,5-alpha]pyridine) is clinically used as a cerebral vasodilator in Japan. However, the effects of ibudilast on retinal blood vessels have not been fully examined. The aim of this study, therefore, was to examine the effects of ibudilast on retinal blood vessels in rats in vivo. Male Wistar rats (8 to 10 weeks old) were anesthetized with thiobutabarbital (120 mg/kg, intraperitoneally (i.p.)). Retinal vascular images were captured with a fundus camera system for small animals, and the diameter of retinal blood vessels was measured. Ibudilast (0.1 and 1 mg/kg, intravenously (i.v.)) elicited a sustained increase in the diameter of retinal blood vessels and heart rate without altering systemic blood pressure. The effects of ibudilast were significantly reduced by treatment with the nonselective cyclooxygenase inhibitor indomethacin (5 mg/kg, i.p.). These results suggest that ibudilast dilates retinal blood vessels through cyclooxygenase-dependent mechanisms in rats in vivo.

  18. Computational Fluid Dynamics Analysis of Pulsatile Blood Flow Behavior in Modelled Stenosed Vessels with Different Severities

    Directory of Open Access Journals (Sweden)

    Mohsen Mehrabi

    2012-01-01

    Full Text Available This study focuses on the behavior of blood flow in the stenosed vessels. Blood is modelled as an incompressible non-Newtonian fluid which is based on the power law viscosity model. A numerical technique based on the finite difference method is developed to simulate the blood flow taking into account the transient periodic behaviour of the blood flow in cardiac cycles. Also, pulsatile blood flow in the stenosed vessel is based on the Womersley model, and fluid flow in the lumen region is governed by the continuity equation and the Navier-Stokes equations. In this study, the stenosis shape is cosine by using Tu and Devil model. Comparing the results obtained from three stenosed vessels with 30%, 50%, and 75% area severity, we find that higher percent-area severity of stenosis leads to higher extrapressure jumps and higher blood speeds around the stenosis site. Also, we observe that the size of the stenosis in stenosed vessels does influence the blood flow. A little change on the cross-sectional value makes vast change on the blood flow rate. This simulation helps the people working in the field of physiological fluid dynamics as well as the medical practitioners.

  19. Study of fluid dynamics reveals direct communications between lymphatic vessels and venous blood vessels at lymph nodes of mice.

    Science.gov (United States)

    Takeda, Kazu; Mori, Shiro; Kodama, Tetsuya

    2017-06-01

    Cancer cells metastasize to lymph nodes, with distant metastasis resulting in poor prognosis. The role of lymph node metastasis (LNM) in the spread of cancer to distant organs remain incompletely characterized. The visualization of flow dynamics in the lymphatic and blood vessels of MXH10/Mo-lpr/lpr mice, which develop systemic swelling of lymph nodes up to 10mm in diameter, has revealed that lymph nodes have the potential to be a direct source of systemic metastasis. However, it is not known whether these fluid dynamics characteristics are universal phenomena present in other strains of laboratory mice. Here we show that the fluid dynamics observed in MXH10/Mo-lpr/lpr mice are the same as those observed in C57BL/6J, BALB/cAJcl and NOD/ShiJic-scidJcl mice. Furthermore, when fluorescent solution was injected into a tumor-bearing lymph node, the flow dynamics observed in the efferent lymphatic vessels and thoracoepigastric vein depended on the type of tumor cell. Our results indicate that fluid dynamics in the lymphatic and blood vessels of MXH10/Mo-lpr/lpr mice are generalized phenomena seen in conventional laboratory mice. We anticipate our results can facilitate studies of the progression of lymphatic metastasis to hematogenous metastasis via lymph nodes and the early diagnosis and treatment of LNM. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. OPTIMAL RESOLUTION FOR AUTOMATIC QUANTIFICATION OF BLOOD VESSELS ON DIGITIZED IMAGES OF THE WHOLE CANCER SECTION

    Directory of Open Access Journals (Sweden)

    Ronan Françoise

    2011-05-01

    Full Text Available Discrepancies concerning the prognostic significance of cancer vascularization can be partly explained by biases due to quantification protocols. We recently recommended a swift, inexpensive and automatic analysis of 2,700 dpi slide scanner images of the whole immunostained sections. Another team, proposed, quite at the same time, to work at 4,000 dpi. The aim of the present paper is to check if information contained in images scanned at 2,700 and 4,000 dpi are relevant and equivalent, when compared to the low magnification of the microscope, in order to propose the best compromise between precision and time expense. To evaluate precisely the amount of information gained or lost according to the resolution used, we compared the number and size of blood vessel profiles, manually detected, on twenty one Hodgkin lymphoma acquired with a scanner (2,700 and 4,000 dpi and with a microscope (16,000 dpi. Results obtained at 4,000 dpi were equivalent to the estimation performed at microscopical level either by a biologist or a pathologist, while tiny vessels were lost at 2,700 dpi. Scanning whole histological sections at 4,000 dpi provides a relevant method for evaluating tumour vascularization, which can be easily automated and standardized.

  1. Perivascular adipose tissue alleviates inflammatory factors and stenosis in diabetic blood vessels.

    Science.gov (United States)

    Li, Tianjia; Liu, Xinnong; Ni, Leng; Wang, Zhanqi; Wang, Wenda; Shi, Tao; Liu, Xiu; Liu, Changwei

    2016-11-11

    Adipose tissue can modulate disease processes in a depot-specific manner. However, the functional properties of perivascular adipocytes, and their influence on the pathophysiology of blood vessel walls, remain to be determined. In this study, we aimed to investigate whether perivascular adipose tissue could have an ameliorative effect on blood vessels damaged in diabetes. Using in vitro coculture, and in vivo transplantation model simulating diabetic angioplasty-induced injury, we showed that perivascular adipose tissue has an important function in protecting blood vessels from high glucose impairment. Levels of inflammatory cytokines, including intercellular cell adhesion molecule-1 and osteopontin, were markedly reduced, whereas that of endothelial nitric-oxide synthase was markedly elevated in vascular walls. These depot-specific differences in blood vessels exposed to high levels of glucose were demonstrable both in vivo, with transplanted adipose tissues, and in vitro, when vascular endothelial cells were cocultured with adipocytes. In addition, intimal hyperplasia was also decreased by transplanted perivascular adipose tissue after balloon injury combined with hyperglycemia. We conclude that perivascular adipocytes can reduce inflammation in blood vessels and promote the normal function of endothelium, which could afford a new therapeutic strategy in vascular walls damaged by diabetes. Copyright © 2016. Published by Elsevier Inc.

  2. 46 CFR 27.203 - What are the requirements for fire detection on towing vessels?

    Science.gov (United States)

    2010-10-01

    ...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... detection on towing vessels? You must have a fire-detection system installed on your vessel to detect engine... use an existing engine-room-monitoring system (with fire-detection capability) instead of a fire...

  3. Nitric oxide dilates rat retinal blood vessels by cyclooxygenase-dependent mechanisms.

    Science.gov (United States)

    Ogawa, Naoto; Mori, Asami; Hasebe, Masami; Hoshino, Maya; Saito, Maki; Sakamoto, Kenji; Nakahara, Tsutomu; Ishii, Kunio

    2009-10-01

    It has been suggested that nitric oxide (NO) stimulates the cyclooxygenase (COX)-dependent mechanisms in the ocular vasculature; however, the importance of the pathway in regulating retinal circulation in vivo remains to be elucidated. Therefore, we investigated the role of COX-dependent mechanisms in NO-induced vasodilation of retinal blood vessels in thiobutabarbital-anesthetized rats with and without neuronal blockade (tetrodotoxin treatment). Fundus images were captured with a digital camera that was equipped with a special objective lens. The retinal vascular response was assessed by measuring changes in diameter of the retinal blood vessel. The localization of COX and soluble guanylyl cyclase in rat retina was examined using immunohistochemistry. The NO donors (sodium nitroprusside and NOR3) increased the diameter of the retinal blood vessels but decreased systemic blood pressure in a dose-dependent manner. Treatment of rats with indomethacin, a nonselective COX inhibitor, or SC-560, a selective COX-1 inhibitor, markedly attenuated the vasodilation of retinal arterioles, but not the depressor response, to the NO donors. However, both the vascular responses to NO donors were unaffected by the selective COX-2 inhibitors NS-398 and nimesulide. Indomethacin did not change the retinal vascular and depressor responses to hydralazine, 8-(4-chlorophenylthio)-guanosine-3', 5'-cyclic monophosphate (a membrane-permeable cGMP analog) and 8-(4-chlorophenylthio)-adenosine-3', 5'-cyclic monophosphate (a membrane-permeable cAMP analog). Treatment with SQ 22536, an adenylyl cyclase inhibitor, but not ODQ, a soluble guanylyl cyclase inhibitor, significantly attenuated the NOR3-induced vasodilation of retinal arterioles. The COX-1 immunoreactivity was found in retinal blood vessels. The retinal blood vessel was faintly stained for soluble guanylyl cyclase, although the apparent immunoreactivities on mesenteric and choroidal blood vessels were observed. These results suggest

  4. Truncated Hormone Inhibits Breast Tumor Blood Vessel Formation, Not Tumor Growth | Center for Cancer Research

    Science.gov (United States)

    The hormone prolactin (PRL) plays a critical role in normal breast development by stimulating the proliferation of mammary cells, the production of milk proteins, and the formation of new mammary blood vessels. Unfortunately, the same cell and vessel growth pathways controlled by PRL in normal cells also operate in breast cancer cells, and elevated plasma PRL is a risk factor for breast cancer, especially in post-menopausal women.

  5. Estimation Of Blood Vessels Functional State By Means Of Analysis Of Temperature Reaction On Occlusive Test

    Directory of Open Access Journals (Sweden)

    A.P. Rytik

    2009-12-01

    Full Text Available Temperature reaction of distant phalanges in the case of the occlusive test has been registered. It has been revealed that the temperature reaction on the occlusive test for the group of patients with disturbances of vessel tone regulation differs from the reaction of norm group. Possible influence of vessel regulation state and volumetric blood supply on the skin temperature dynamics has been estimated. Diagnostic ability of the temperature occlusive test has been investigated

  6. Estimation Of Blood Vessels Functional State By Means Of Analysis Of Temperature Reaction On Occlusive Test

    OpenAIRE

    A.P. Rytik; E.V. Miroshnichenko; A.A. Sagaidachnyi; A.V. Skripal; A.A. Protopopov; D.A. Usanov

    2009-01-01

    Temperature reaction of distant phalanges in the case of the occlusive test has been registered. It has been revealed that the temperature reaction on the occlusive test for the group of patients with disturbances of vessel tone regulation differs from the reaction of norm group. Possible influence of vessel regulation state and volumetric blood supply on the skin temperature dynamics has been estimated. Diagnostic ability of the temperature occlusive test has been investigated

  7. Transgenic quail production by microinjection of lentiviral vector into the early embryo blood vessels.

    Directory of Open Access Journals (Sweden)

    Zifu Zhang

    Full Text Available Several strategies have been used to generate transgenic birds. The most successful method so far has been the injection of lentiviral vectors into the subgerminal cavity of a newly laid egg. We report here a new, easy and effective way to produce transgenic quails through direct injection of a lentiviral vector, containing an enhanced-green fluorescent protein (eGFP transgene, into the blood vessels of quail embryos at Hamburger-Hamilton stage 13-15 (HH13-15. A total of 80 embryos were injected and 48 G0 chimeras (60% were hatched. Most injected embryo organs and tissues of hatched quails were positive for eGFP. In five out of 21 mature G0 male quails, the semen was eGFP-positive, as detected by polymerase chain reaction (PCR, indicating transgenic germ line chimeras. Testcross and genetic analyses revealed that the G0 quail produced transgenic G1 offspring; of 46 G1 hatchlings, 6 were transgenic (6/46, 13.0%. We also compared this new method with the conventional transgenesis using stage X subgerminal cavity injection. Total 240 quail embryos were injected by subgerminal cavity injection, of which 34 (14.1% were hatched, significantly lower than the new method. From these hatched quails semen samples were collected from 19 sexually matured males and tested for the transgene by PCR. The transgene was present in three G0 male quails and only 4/236 G1 offspring (1.7% were transgenic. In conclusion, we developed a novel bird transgenic method by injection of lentiviral vector into embryonic blood vessel at HH 13-15 stage, which result in significant higher transgenic efficiency than the conventional subgerminal cavity injection.

  8. Vessel network detection using contour evolution and color components

    Energy Technology Data Exchange (ETDEWEB)

    Ushizima, Daniela; Medeiros, Fatima; Cuadros, Jorge; Martins, Charles

    2011-06-22

    Automated retinal screening relies on vasculature segmentation before the identification of other anatomical structures of the retina. Vasculature extraction can also be input to image quality ranking, neovascularization detection and image registration, among other applications. There is an extensive literature related to this problem, often excluding the inherent heterogeneity of ophthalmic clinical images. The contribution of this paper relies on an algorithm using front propagation to segment the vessel network. The algorithm includes a penalty in the wait queue on the fast marching heap to minimize leakage of the evolving interface. The method requires no manual labeling, a minimum number of parameters and it is capable of segmenting color ocular fundus images in real scenarios, where multi-ethnicity and brightness variations are parts of the problem.

  9. Tissue Engineering of Blood Vessels: Functional Requirements, Progress, and Future Challenges.

    Science.gov (United States)

    Kumar, Vivek A; Brewster, Luke P; Caves, Jeffrey M; Chaikof, Elliot L

    2011-09-01

    Vascular disease results in the decreased utility and decreased availability of autologus vascular tissue for small diameter (engineered replacement vessels represent an ideal solution to this clinical problem. Ongoing progress requires combined approaches from biomaterials science, cell biology, and translational medicine to develop feasible solutions with the requisite mechanical support, a non-fouling surface for blood flow, and tissue regeneration. Over the past two decades interest in blood vessel tissue engineering has soared on a global scale, resulting in the first clinical implants of multiple technologies, steady progress with several other systems, and critical lessons-learned. This review will highlight the current inadequacies of autologus and synthetic grafts, the engineering requirements for implantation of tissue-engineered grafts, and the current status of tissue-engineered blood vessel research.

  10. In vitro fabrication of functional three-dimensional tissues with perfusable blood vessels.

    Science.gov (United States)

    Sekine, Hidekazu; Shimizu, Tatsuya; Sakaguchi, Katsuhisa; Dobashi, Izumi; Wada, Masanori; Yamato, Masayuki; Kobayashi, Eiji; Umezu, Mitsuo; Okano, Teruo

    2013-01-01

    In vitro fabrication of functional vascularized three-dimensional tissues has been a long-standing objective in the field of tissue engineering. Here we report a technique to engineer cardiac tissues with perfusable blood vessels in vitro. Using resected tissue with a connectable artery and vein as a vascular bed, we overlay triple-layer cardiac cell sheets produced from coculture with endothelial cells, and support the tissue construct with media perfused in a bioreactor. We show that endothelial cells connect to capillaries in the vascular bed and form tubular lumens, creating in vitro perfusable blood vessels in the cardiac cell sheets. Thicker engineered tissues can be produced in vitro by overlaying additional triple-layer cell sheets. The vascularized cardiac tissues beat and can be transplanted with blood vessel anastomoses. This technique may create new opportunities for in vitro tissue engineering and has potential therapeutic applications.

  11. The use of high-hydrostatic pressure treatment to decellularize blood vessels.

    Science.gov (United States)

    Funamoto, Seiichi; Nam, Kwangwoo; Kimura, Tsuyoshi; Murakoshi, Ayako; Hashimoto, Yoshihide; Niwaya, Kazuo; Kitamura, Soichiro; Fujisato, Toshiya; Kishida, Akio

    2010-05-01

    A decellularization method using high-hydrostatic pressure (HHP) technology (>600MPa) is described. The HHP disrupts the cells inside the tissue. The cell debris can be eliminated with a simple washing process, producing clean, decellularized tissue. In this study, porcine aortic blood vessel was decellularized by HHP. The mechanical properties and in vivo performance of the decellularized tissue were evaluated. Mechanical properties of the decellularized tissue were not altered by the HHP treatment. Reduced inflammation of the decellularized tissue was confirmed by xenogenic transplant experimentation. An allogenic transplantation study showed that decellularized blood vessel endured the arterial blood pressure, and there was no clot formation on the luminal surface. In addition, cellular infiltration into the vessel wall was observed 4 weeks after implantation, suggesting that HHP treatments could be applied widely as a high-quality decellularization method. Copyright 2010 Elsevier Ltd. All rights reserved.

  12. Blood vessel damage correlated with irradiance for in vivo vascular targeted photodynamic therapy

    Science.gov (United States)

    Zhang, Jinde; Tan, Zou; Niu, Xiangyu; Lin, Linsheng; Lin, Huiyun; Li, Buhong

    2016-10-01

    Vascular targeted photodynamic therapy (V-PDT) has been widely utilized for the prevention or treatment of vascular-related diseases, including age-related macular degeneration, port-wine stains and prostate cancer. In order to quantitative assessment the blood vessel damage during V-PDT, nude mice were implanted with Titanium dorsal skin window chambers for in vivo V-PDT studies. For treatments, various irradiances including 50, 75, 100 and 200 mW/cm2 provided by a 532 nm semiconductor laser were performed with the same total light dose of 30 J/cm2 after the mice were intravenously injection of Rose Bengal for 25 mg/Kg body weight. Laser speckle imaging and microscope were used to monitor blood flow dynamics and vessel constriction during and after V-PDT, respectively. The V-PDT induced vessel damages between different groups were compared. The results show that significant difference in blood vessel damage was found between the lower irradiances (50, 75 and 100 mW/cm2) and higher irradiance (200 mW/cm2), and the blood vessel damage induced by V-PDT is positively correlated with irradiance. This study implies that the optimization of irradiance is required for enhancing V-PDT therapeutic efficiency.

  13. Mathematical modelling for trajectories of magnetic nanoparticles in a blood vessel under magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Shashi, E-mail: shashisharma1984@gmail.com; Katiyar, V.K.; Singh, Uaday

    2015-04-01

    A mathematical model is developed to describe the trajectories of a cluster of magnetic nanoparticles in a blood vessel for the application of magnetic drug targeting (MDT). The magnetic nanoparticles are injected into a blood vessel upstream from a malignant tissue and are captured at the tumour site with help of an applied magnetic field. The applied field is produced by a rare earth cylindrical magnet positioned outside the body. All forces expected to significantly affect the transport of nanoparticles were incorporated, including magnetization force, drag force and buoyancy force. The results show that particles are slow down and captured under the influence of magnetic force, which is responsible to attract the magnetic particles towards the magnet. It is optimized that all particles are captured either before or at the centre of the magnet (z≤0) when blood vessel is very close proximity to the magnet (d=2.5 cm). However, as the distance between blood vessel and magnet (d) increases (above 4.5 cm), the magnetic nanoparticles particles become free and they flow away down the blood vessel. Further, the present model results are validated by the simulations performed using the finite element based COMSOL software. - Highlights: • A mathematical model is developed to describe the trajectories of magnetic nanoparticles. • The dominant magnetic, drag and buoyancy forces are considered. • All particles are captured when distance between blood vessel and magnet (d) is up to 4.5 cm. • Further increase in d value (above 4.5 cm) results the free movement of magnetic particles.

  14. Mathematical modelling for trajectories of magnetic nanoparticles in a blood vessel under magnetic field

    International Nuclear Information System (INIS)

    Sharma, Shashi; Katiyar, V.K.; Singh, Uaday

    2015-01-01

    A mathematical model is developed to describe the trajectories of a cluster of magnetic nanoparticles in a blood vessel for the application of magnetic drug targeting (MDT). The magnetic nanoparticles are injected into a blood vessel upstream from a malignant tissue and are captured at the tumour site with help of an applied magnetic field. The applied field is produced by a rare earth cylindrical magnet positioned outside the body. All forces expected to significantly affect the transport of nanoparticles were incorporated, including magnetization force, drag force and buoyancy force. The results show that particles are slow down and captured under the influence of magnetic force, which is responsible to attract the magnetic particles towards the magnet. It is optimized that all particles are captured either before or at the centre of the magnet (z≤0) when blood vessel is very close proximity to the magnet (d=2.5 cm). However, as the distance between blood vessel and magnet (d) increases (above 4.5 cm), the magnetic nanoparticles particles become free and they flow away down the blood vessel. Further, the present model results are validated by the simulations performed using the finite element based COMSOL software. - Highlights: • A mathematical model is developed to describe the trajectories of magnetic nanoparticles. • The dominant magnetic, drag and buoyancy forces are considered. • All particles are captured when distance between blood vessel and magnet (d) is up to 4.5 cm. • Further increase in d value (above 4.5 cm) results the free movement of magnetic particles

  15. Effect of Rolling Massage on the Vortex Flow in Blood Vessels with Lattice Boltzmann Simulation

    Science.gov (United States)

    Yi, Hou Hui

    The rolling massage manipulation is a classic Chinese Medical Massage, which is a nature therapy in eliminating many diseases. Here, the effect of the rolling massage on the cavity flows in blood vessel under the rolling manipulation is studied by the lattice Boltzmann simulation. The simulation results show that the vortex flows are fully disturbed by the rolling massage. The flow behavior depends on the rolling velocity and the rolling depth. Rolling massage has a better effect on the flows in the cavity than that of the flows in a planar blood vessel. The result is helpful to understand the mechanism of the massage and develop the rolling techniques.

  16. Blood vessel segmentation algorithms - Review of methods, datasets and evaluation metrics.

    Science.gov (United States)

    Moccia, Sara; De Momi, Elena; El Hadji, Sara; Mattos, Leonardo S

    2018-05-01

    Blood vessel segmentation is a topic of high interest in medical image analysis since the analysis of vessels is crucial for diagnosis, treatment planning and execution, and evaluation of clinical outcomes in different fields, including laryngology, neurosurgery and ophthalmology. Automatic or semi-automatic vessel segmentation can support clinicians in performing these tasks. Different medical imaging techniques are currently used in clinical practice and an appropriate choice of the segmentation algorithm is mandatory to deal with the adopted imaging technique characteristics (e.g. resolution, noise and vessel contrast). This paper aims at reviewing the most recent and innovative blood vessel segmentation algorithms. Among the algorithms and approaches considered, we deeply investigated the most novel blood vessel segmentation including machine learning, deformable model, and tracking-based approaches. This paper analyzes more than 100 articles focused on blood vessel segmentation methods. For each analyzed approach, summary tables are presented reporting imaging technique used, anatomical region and performance measures employed. Benefits and disadvantages of each method are highlighted. Despite the constant progress and efforts addressed in the field, several issues still need to be overcome. A relevant limitation consists in the segmentation of pathological vessels. Unfortunately, not consistent research effort has been addressed to this issue yet. Research is needed since some of the main assumptions made for healthy vessels (such as linearity and circular cross-section) do not hold in pathological tissues, which on the other hand require new vessel model formulations. Moreover, image intensity drops, noise and low contrast still represent an important obstacle for the achievement of a high-quality enhancement. This is particularly true for optical imaging, where the image quality is usually lower in terms of noise and contrast with respect to magnetic

  17. Compressed sensing based simultaneous black- and gray-blood carotid vessel wall MR imaging.

    Science.gov (United States)

    Li, Bo; Li, Hao; Kong, Hanjing; Dong, Li; Zhang, Jue; Fang, Jing

    2017-05-01

    In this study, we sought to demonstrate the blood suppression performance, image quality and morphological measurements for compressed sensing (CS) based simultaneous 3D black- and gray-blood imaging sequence (CS-siBLAG) in carotid vessel wall MR imaging. Seven healthy volunteers and five patients were recruited. Healthy subjects underwent five CS-siBLAG scans with 1, 2, 3, 4 and 5-fold accelerations. Signal-to-tissue ratio (STR) and contrast-to-tissue ratio (CTR) were computed as the measures of flowing signal suppression performance and the image quality for black-blood imaging of the technique. Vessel lumen area (LA) and wall area (WA) were compared between fully sampled acquisition and each accelerated acquisition. Patients underwent three CS-siBLAG scans with 1, 3 and 5-fold accelerations as well as a 3D time of flight (3D TOF) scan. Two radiologists reviewed the under-sampled black- and gray-blood image quality. STR and CTR values obtained with 2 to 5-fold accelerations were not significantly different from those with full acquisition. LA and WA measured at 2×, 3×, 4× and 5× were all highly correlated to the corresponding values at 1×. For patients imaging, two radiologists both found that the dual-contrast images at 3× acceleration exhibited comparable image quality to that of the fully sampled acquisition, and that the images at 5× exhibited slightly blurred vessel wall and outer vessel wall boundaries. By combining the CS under-sampling pattern and reconstruction, pseudo-centric phase encoding order and dual blood contrast sequences, this technique provides spatially registered black- and gray-blood images and excellent visualization for vessel wall imaging and gray-blood imaging in a short scan time. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Contact-inhibited chemotaxis in de novo and sprouting blood-vessel growth.

    Directory of Open Access Journals (Sweden)

    Roeland M H Merks

    2008-09-01

    Full Text Available Blood vessels form either when dispersed endothelial cells (the cells lining the inner walls of fully formed blood vessels organize into a vessel network (vasculogenesis, or by sprouting or splitting of existing blood vessels (angiogenesis. Although they are closely related biologically, no current model explains both phenomena with a single biophysical mechanism. Most computational models describe sprouting at the level of the blood vessel, ignoring how cell behavior drives branch splitting during sprouting. We present a cell-based, Glazier-Graner-Hogeweg model (also called Cellular Potts Model simulation of the initial patterning before the vascular cords form lumens, based on plausible behaviors of endothelial cells. The endothelial cells secrete a chemoattractant, which attracts other endothelial cells. As in the classic Keller-Segel model, chemotaxis by itself causes cells to aggregate into isolated clusters. However, including experimentally observed VE-cadherin-mediated contact inhibition of chemotaxis in the simulation causes randomly distributed cells to organize into networks and cell aggregates to sprout, reproducing aspects of both de novo and sprouting blood-vessel growth. We discuss two branching instabilities responsible for our results. Cells at the surfaces of cell clusters attempting to migrate to the centers of the clusters produce a buckling instability. In a model variant that eliminates the surface-normal force, a dissipative mechanism drives sprouting, with the secreted chemical acting both as a chemoattractant and as an inhibitor of pseudopod extension. Both mechanisms would also apply if force transmission through the extracellular matrix rather than chemical signaling mediated cell-cell interactions. The branching instabilities responsible for our results, which result from contact inhibition of chemotaxis, are both generic developmental mechanisms and interesting examples of unusual patterning instabilities.

  19. Mouse lung contains endothelial progenitors with high capacity to form blood and lymphatic vessels

    Directory of Open Access Journals (Sweden)

    Barleon Bernhard

    2010-07-01

    Full Text Available Abstract Background Postnatal endothelial progenitor cells (EPCs have been successfully isolated from whole bone marrow, blood and the walls of conduit vessels. They can, therefore, be classified into circulating and resident progenitor cells. The differentiation capacity of resident lung endothelial progenitor cells from mouse has not been evaluated. Results In an attempt to isolate differentiated mature endothelial cells from mouse lung we found that the lung contains EPCs with a high vasculogenic capacity and capability of de novo vasculogenesis for blood and lymph vessels. Mouse lung microvascular endothelial cells (MLMVECs were isolated by selection of CD31+ cells. Whereas the majority of the CD31+ cells did not divide, some scattered cells started to proliferate giving rise to large colonies (> 3000 cells/colony. These highly dividing cells possess the capacity to integrate into various types of vessels including blood and lymph vessels unveiling the existence of local microvascular endothelial progenitor cells (LMEPCs in adult mouse lung. EPCs could be amplified > passage 30 and still expressed panendothelial markers as well as the progenitor cell antigens, but not antigens for immune cells and hematopoietic stem cells. A high percentage of these cells are also positive for Lyve1, Prox1, podoplanin and VEGFR-3 indicating that a considerabe fraction of the cells are committed to develop lymphatic endothelium. Clonogenic highly proliferating cells from limiting dilution assays were also bipotent. Combined in vitro and in vivo spheroid and matrigel assays revealed that these EPCs exhibit vasculogenic capacity by forming functional blood and lymph vessels. Conclusion The lung contains large numbers of EPCs that display commitment for both types of vessels, suggesting that lung blood and lymphatic endothelial cells are derived from a single progenitor cell.

  20. Resonance frequency of microbubbles in small blood vessels: a numerical study

    International Nuclear Information System (INIS)

    Sassaroli, E; Hynynen, K

    2005-01-01

    Microbubbles are currently used as ultrasound contrast agents. Their potential therapeutic applications are also under investigation. This work is designed to provide some insight into the mechanisms of energy absorption and deposition by a preformed gas bubble in the microvasculature to optimize its efficacy. In the linear regime, the most favourable condition for the transfer of energy from an ultrasonic field to a gas bubble occurs when the centre frequency of the ultrasonic field equals the resonance frequency of the bubble. The resonance frequency of gas microbubbles has been investigated up to now mainly in unbounded liquids; however when bubbles are confined in small regions, their resonance frequency is strongly affected by the surrounding boundaries. A parametric study on how the resonance frequency of microbubbles in blood vessels is affected by the bubble radius, vessel radius and the bubble position in the vessel is presented. The resonance frequency decreases below its free value with decreasing vessel radius for vessels smaller than 200-300 μm depending on the bubble size. This model suggests the possibility of using ultrasound in a range of frequencies that are, in general, lower than the ones used now for therapeutic and diagnostic applications of ultrasound (a few MHz). When microbubbles oscillate at their resonance frequency they absorb and therefore emit more energy. This energy may allow specific blood vessels to be targeted for both diagnostic and therapeutic applications of ultrasound

  1. Automated detection and classification of major retinal vessels for determination of diameter ratio of arteries and veins

    Science.gov (United States)

    Muramatsu, Chisako; Hatanaka, Yuji; Iwase, Tatsuhiko; Hara, Takeshi; Fujita, Hiroshi

    2010-03-01

    Abnormalities of retinal vasculatures can indicate health conditions in the body, such as the high blood pressure and diabetes. Providing automatically determined width ratio of arteries and veins (A/V ratio) on retinal fundus images may help physicians in the diagnosis of hypertensive retinopathy, which may cause blindness. The purpose of this study was to detect major retinal vessels and classify them into arteries and veins for the determination of A/V ratio. Images used in this study were obtained from DRIVE database, which consists of 20 cases each for training and testing vessel detection algorithms. Starting with the reference standard of vasculature segmentation provided in the database, major arteries and veins each in the upper and lower temporal regions were manually selected for establishing the gold standard. We applied the black top-hat transformation and double-ring filter to detect retinal blood vessels. From the extracted vessels, large vessels extending from the optic disc to temporal regions were selected as target vessels for calculation of A/V ratio. Image features were extracted from the vessel segments from quarter-disc to one disc diameter from the edge of optic discs. The target segments in the training cases were classified into arteries and veins by using the linear discriminant analysis, and the selected parameters were applied to those in the test cases. Out of 40 pairs, 30 pairs (75%) of arteries and veins in the 20 test cases were correctly classified. The result can be used for the automated calculation of A/V ratio.

  2. Wave reflection and transmission in multiply stented blood vessels

    Science.gov (United States)

    Papathanasiou, T. K.; Movchan, A. B.; Bigoni, D.

    2017-06-01

    Closed circulatory systems display an exquisite balance between vascular elasticity and viscous fluid effects, to induce pulse-smoothing and avoid resonance during the cardiac cycle. Stents in the arterial tree alter this balance through stiffening and because a periodic structure is introduced, capable of interacting with the fluid in a complex way. While the former feature has been investigated, the latter received no attention so far. But periodic structures are the building blocks of metamaterials, known for their `non-natural' behaviour. Thus, the investigation of a stent's periodic microstructure dynamical interactions is crucial to assess possible pathological responses. A one-dimensional fluid-structure interaction model, simple enough to allow an analytical solution for situations of interest involving one or two interacting stents, is introduced. It is determined: (i) whether or not frequency bands exist in which reflected blood pulses are highly increased and (ii) if these bands are close to the characteristic frequencies of arteries and finally, (iii) if the internal structure of the stent can sensibly affect arterial blood dynamics. It is shown that, while the periodic structure of an isolated stent can induce anomalous reflection only in pathological conditions, the presence of two interacting stents is more critical, and high reflection can occur at frequencies not far from the physiological values.

  3. Infrared tomography for diagnostic imaging of port wine stain blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The objective of this work is the development of Infrared Tomography (IRT) for detecting and characterizing subsurface chromophores in human skin. Characterization of cutaneous chromophores is crucial for advances in the laser treatment of pigmented lesions (e.g., port wine stain birthmarks and tatoos). Infrared tomography (IRT) uses a fast infrared focal plane array (IR-FPA) to detect temperature rises in a substrate induced by pulsed radiation. A pulsed laser is used to produce transient heating of an object. The temperature rise, due to the optical absorption of the pulsed laser light, creates an increase in infrared emission which is measured by the IR-FPA. Although the application of IRT to image subsurface cracks due to metal fatigue is a topic of great interest in the aircraft industry, the application to image subsurface chromophores in biological materials is novel. We present an image recovery method based on a constrained conjugate gradient algorithm that has obtained the first ever high quality images of port wine blood vessels.

  4. Mathematical Modeling of Bingham Plastic Model of Blood Flow Through Stenotic Vessel

    OpenAIRE

    S.R. Verma

    2014-01-01

    The aim of the present paper is to study the axially symmetric, laminar, steady, one-dimensional flow of blood through narrow stenotic vessel. Blood is considered as Bingham plastic fluid. The analytical results such as pressure drop, resistance to flow and wall shear stress have been obtained. Effect of yield stress and shape of stenosis on resistance to flow and wall shear stress have been discussed through tables and graphically. It has been shown that resistance to flow and th...

  5. Failure to show decrease in small pulmonary blood vessels in rats with experimental pulmonary hypertension.

    OpenAIRE

    Kay, J M; Suyama, K L; Keane, P M

    1982-01-01

    We induced chronic pulmonary hypertension in one group of rats by exposing them to chronic hypobaric hypoxia (380 mm Hg for three weeks) and in another group by administering a single subcutaneous dose of monocrotaline (60 mg/kg body weight). Both groups of rats showed increase of the right ventricular mean systolic blood pressure and right ventricular hypertrophy. We measured the surface area of histological sections of the left or right lungs and counted all small blood vessels with an exte...

  6. The Fine Structure of Some Blood Vessels of the Earthworm, Eisenia foetida

    Science.gov (United States)

    Hama, Kiyoshi

    1960-01-01

    The fine structure of the main dorsal and ventral circulatory trunks and of the subneural vessels and capillaries of the ventral nerve cord of the earthworm, Eisenia foetida, has been studied with the electron microscope. All of these vessels are lined internally by a continuous extracellular basement membrane varying in thickness (0.03 to 1 µ) with the vessel involved. The dorsal, ventral, and subneural vessels display inside this membrane scattered flattened macrophagic or leucocytic cells called amebocytes. These lie against the inner lining of the basement membrane, covering only a small fraction of its surface. They have long, attenuated branching cell processes. All of these vessels are lined with a continuous layer of unfenestrated endothelial cells displaying myofilaments and hence qualifying for the designation of "myoendothelial cells." The degree of muscular specialization varies over a spectrum, however, ranging from a delicate endowment of thin myofilaments in the capillary myoendothelial cells to highly specialized myoendothelial cells in the main pulsating dorsal blood trunk, which serves as the worm's "heart" or propulsive "aorta." The myoendothelial cells most specialized for contraction display well organized sarcoplasmic reticulum and myofibrils with thick and thin myofilaments resembling those of the earthworm body wall musculature. In the ventral circulatory trunk, circular and longitudinal myofilaments are found in each myoendothelial cell. In the dorsal trunk, the lining myoendothelial cells contain longitudinal myofilaments. Outside these cells are circular muscle cells. The lateral parts of the dorsal vessels have an additional outer longitudinal muscle layer. The blood plasma inside all of the vessels shows scattered particles representing the circulating earthworm blood pigment, erythrocruorin. PMID:14399190

  7. Cerebral blood flow in small vessel disease : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Shi, Yulu; Thrippleton, Michael J; Makin, Stephen D; Marshall, Ian; Geerlings, Mirjam I; de Craen, Anton Jm; van Buchem, Mark A; Wardlaw, Joanna M

    2016-01-01

    White matter hyperintensities are frequent on neuroimaging of older people and are a key feature of cerebral small vessel disease. They are commonly attributed to chronic hypoperfusion, although whether low cerebral blood flow is cause or effect is unclear. We systematically reviewed studies that

  8. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  9. C-reactive protein and chitinase 3-like protein 1 as biomarkers of spatial redistribution of retinal blood vessels on digital retinal photography in patients with diabetic retinopathy.

    Science.gov (United States)

    Cekić, Sonja; Cvetković, Tatjana; Jovanović, Ivan; Jovanović, Predrag; Pesić, Milica; Stanković Babić, Gordana; Milenković, Svetislav; Risimić, Dijana

    2014-08-20

    The aim of the study was to investigate the correlation between the levels of C-reactive protein (CRP) and chitinase 3-like protein 1 (YKL-40) in blood samples with morpohometric parameters of retinal blood vessels in patients with diabetic retinopathy. Blood laboratory examination of 90 patients included the measurement of glycemia, HbA1C, total cholesterol, LDL-C, HDL-C, triglycerides and CRP. Levels of YKL-40 were detected and measured in serum by ELISA (Micro VueYKL-40 EIA Kit, Quidel Corporation, San Diego, USA). YKL-40 correlated positively with diameter and negatively with number of retinal blood vessels. The average number of the blood vessels per retinal zone was significantly higher in the group of patients with mild non-proliferative diabetic retinopathy than in the group with severe form in the optic disc and all five retinal zones. The average outer diameter of the evaluated retinal zones and optic disc vessels was significantly higher in the group with severe compared to the group with mild diabetic retinopathy. Morphological analysis of the retinal vessels on digital fundus photography and correlation with YKL-40 may be valuable for the follow-up of diabetic retinopathy.

  10. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  12. Evaluation of local density enhancement of microcapsules in artificial blood vessel during exposure to focused ultrasound

    Science.gov (United States)

    Nakamoto, Ryusuke; Masuda, Kohji; Watarai, Nobuyuki; Taguchi, Yuto; Kato, Toshikazu; Yoshinaga, Takashi; Miyamoto, Yoshitaka; Chiba, Toshio

    2011-09-01

    We have proposed a physical DDS (Drug Delivery System) which makes use of microcapsules of μm size, which may contain a specified drug and also are easily affected by ultrasound exposure near their resonant frequency, to release various kinds of medications. These capsules are easily detected and actuated by ultrasound. However, because of the diffusion of capsules after injection into human body, it was difficult to enhance the efficiency of drug delivery. Thus we have considered a method for controlling the density of capsules in flow which uses acoustic radiation force, which moves the capsules to balance flow resistance. We have experimented with trapping microcapsules or microbubbles in flow of an artificial blood vessel. We have evaluated the effect of radiation force by measuring the trapped area of capsules or bubbles for various frequencies, sound pressures, and exposure times of sinusoidal ultrasound. The trapped area of capsules or bubbles increased with sound pressure and exposure time, and decreased with frequency. From those results, we have derived optimal conditions for trapping the capsules or bubbles.

  13. Mast cells present protrusions into blood vessels upon tracheal allergen challenge in mice.

    Directory of Open Access Journals (Sweden)

    Oishee Bose

    Full Text Available Mast cells (MC and myeloid dendritic cells (DC act proximally in detecting and processing antigens and immune insults. We sought to understand their comparative dynamic behavior with respect to the airway epithelium in the steady state and in response to an allergic stimulus in mouse trachea. We devised methods to label MC in living trachea and to demonstrate that MC and DC occupy distinct layers of the tracheal mucosa, with DC being closer to the lumen. DC numbers doubled after allergen challenge, but MC numbers remained stable. MC and DC migrated minimally in either steady state or allergen-challenge conditions, and their interactions with one another appeared to be stochastic and relatively infrequent. While DC, unlike MC, exhibited probing behaviors involving dendrites, these projections did not cross the epithelium into the airway lumen. MC typically were located too far from the epithelial surface to contact the tracheal lumen. However, MC had protrusions toward and into blood vessels, likely to load with IgE. Thus, DC and MC occupy distinct niches and engage in sessile surveillance in the mouse trachea. Little or no access of these cell types to the airway lumen suggests that trans-epithelial transport of proteins in the steady state would be required for them to access luminal antigens.

  14. Towards cavitation-enhanced permeability in blood vessel on a chip

    Science.gov (United States)

    De Luca, R.; Silvani, G.; Scognamiglio, C.; Sinibaldi, G.; Peruzzi, G.; Chinappi, M.; Kiani, M. F.; Casciola, C. M.

    2017-08-01

    The development of targeted delivery systems releasing pharmaceutical agents directly at the desired site of action may improve their therapeutic efficiency while minimizing damage to healthy tissues, toxicity to the patient and drug waste. In this context, we have developed a bio-inspired microdevice mimicking the tumour microvasculature which represents a valuable tool for assessing the enhancement of blood vessel permeability due to cavitation. This novel system allows us to investigate the effects of ultrasound-driven microbubbles that temporarily open the endothelial intercellular junctions allowing drug to extravasate blood vessels into tumour tissues. The blood vessel on a chip consists of a tissue chamber and two independent vascular channels (width 200 µm, height 100 µm, length 2762 µm) cultured with endothelial cells placed side-by-side and separated by a series of 3 µm pores. Its geometry and dimensions mimic the three-dimensional morphology, size and flow characteristics of microvessels in vivo. The early stage of this project had a twofold objective: 1. To define the protocol for culturing of Human Umbilical Vein Endothelial Cells (HUVECs) within the vascular channel; 2. To develop a fluorescence based microscopy technique for measuring permeability. We have developed a reliable and reproducible protocol to culture endothelial cells within the artificial vessels in a realistic manner: HUVECs show the typical elongated shape in the direction of flow, exhibit tight junction formation and form a continuous layer with a central lumen that completely covers the channels wall. As expected, the permeability of cell-free device is higher than the one cultured with HUVECs in the vascular channels. The proposed blood vessel on a chip and the permeability measurement protocol have a significant potential to allow for the study of cavitation-enhanced permeability of the endothelium and improve efficiency in screening drug delivery systems.

  15. C - reactive protein and chitinase 3-like protein 1 as biomarkers of spatial redistribution of retinal blood vessels on digital retinal photography in patients with diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Sonja Predrag Cekic

    2014-08-01

    Full Text Available The aim of the study was to investegate the correlation between the levels of CRP and YKL-40 in blood samples with morphometric parameters of retinal blood vessels in patients with diabetic retinopathy.Blood laboratory examination of 90 patients included the measurement of glycemia, HbA1C, total cholesterol, LDL-C, HDL-C, triglycerides and CRP. Levels of YKL-40 were detected and measured in serum by ELISA (Micro VueYKL-40 EIA Kit, Quidel Corporation, San Diego, USA.Morphmetric analysis was performed with ImageJ software (http://rsbweb.nih.gov/ij/ for digital retinal photography. We measured the number, diameter of retinal blood vessels in five different parts concentric to the optic disc. Differences between the morphometric parameters and the blood test analysis results were evaluated using the Student’s t – test. One Way ANOVA was used to establish the significance of differences.CRP and YKL-40 levels were moderately higher in the group of patients with severe diabetic retinopathy. Levels of YKL-40 correlated positively with diameter and negatively with number of retinal blood vessels. The average number of the blood vessels per retinal zone was significantly higher in the group of patients with mild non-proliferative diabetic retinopathy than in the group with severe form in the optic disc and all five retinal zones. The average outer diameter of the evaluated retinal zones and optic disc vessels was significantly higher in the group with severe compared to the group with mild diabetic retinopathy.Morphological analysis of the retinal vessels on digital fundus photography and correlation with YKL-40 may be valuable for the follow-up of diabetic retinopathy.

  16. Early Generation of New PrPSc on Blood Vessels after Brain Microinjection of Scrapie in Mice.

    Science.gov (United States)

    Chesebro, Bruce; Striebel, James; Rangel, Alejandra; Phillips, Katie; Hughson, Andrew; Caughey, Byron; Race, Brent

    2015-09-22

    Aggregation of misfolded host proteins in the central nervous system is believed to be important in the pathogenic process in several neurodegenerative diseases of humans, including prion diseases, Alzheimer's disease, and Parkinson's disease. In these diseases, protein misfolding and aggregation appear to expand through a process of seeded polymerization. Prion diseases occur in both humans and animals and are experimentally transmissible orally or by injection, thus providing a controllable model of other neurodegenerative protein misfolding diseases. In rodents and ruminants, prion disease has a slow course, lasting months to years. Although prion infectivity has been detected in brain tissue at 3 to 4 weeks postinfection (p.i.), the details of early prion replication in the brain are not well understood. Here we studied the localization and quantitation of PrPSc generation in vivo starting at 30 min postmicroinjection of scrapie into the brain. In C57BL mice at 3 days p.i., generation of new PrPSc was detected by immunohistochemistry and immunoblot assays, and at 7 days p.i., new generation was confirmed by real-time quaking-induced conversion assay. The main site of new PrPSc generation was near the outer basement membrane of small and medium blood vessels. The finding and localization of replication at this site so early after injection have not been reported previously. This predominantly perivascular location suggested that structural components of the blood vessel basement membrane or perivascular astrocytes might act as cofactors in the initial generation of PrPSc. The location of PrPSc replication at the basement membrane also implies a role for the brain interstitial fluid drainage in the early infection process. Neurodegenerative diseases, including Alzheimer's disease, Parkinson's disease, and prion diseases, of humans are characterized by misfolding and aggregation of certain proteins, resulting in the destruction of brain tissue. In these diseases

  17. Method of detecting construction faults in concrete pressure vessels

    International Nuclear Information System (INIS)

    Robertson, S.A.; Duhoux, M.; Dawance, G.; Carrie, C.; Morel, D.

    1976-01-01

    A major problem in the design and construction of concrete pressure vessels for nuclear power stations is the risk of excessive air leaks through the concrete itself, due to faulty construction. The 'sonic coring' method of non-destructive concrete testing has been used successfully in pile and diaphragm wall construction control for several years, and the potential use of this method to control the presence of faults in concrete pressure vessels is here described. (author)

  18. In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV.

    Science.gov (United States)

    Park, Hanwook; Park, Jun Hong; Lee, Sang Joon

    2016-11-28

    Measurements of the hemodynamic information of blood flows, especially wall shear stress (WSS), in animal models with circulatory vascular diseases (CVDs) are important to understand the pathological mechanism of CVDs. In this study, X-ray particle image velocimetry (PIV) with high spatial resolution was applied to obtain velocity field information in stenosed blood vessels with high WSS. 3D clips fabricated with a 3D printer were applied to the abdominal aorta of a rat cadaver to induce artificial stenosis in the real blood vessel of an animal model. The velocity and WSS information of blood flows in the stenosed vessel were obtained and compared at various stenosis severities. In vivo measurement was also conducted by fastening a stenotic clip on a live rat model through surgical intervention to reduce the flow rate to match the limited temporal resolution of the present X-ray PIV system. Further improvement of the temporal resolution of the system might be able to provide in vivo measurements of hemodynamic information from animal disease models under physiological conditions. The present results would be helpful for understanding the relation between hemodynamic characteristics and the pathological mechanism in animal CVD models.

  19. Detecting culprit vessel of coronary artery disease with SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Zhou Wen; Peng Yong; Su Yuwen; Tian Jianhe; Gai lue; Sun Zhijun

    2002-01-01

    Objective: To assess the value of detecting culprit vessel of coronary artery disease (CAD) with SPECT 99 Tc m -MIBI myocardial imaging. Methods: Forty-six patients with CAD were studied. Every patients had multiple-vessel lesion showed by coronary arteriography and was treated by revascularization as percutaneous transluminal angioplasty (PTCA), coronary artery bypass graft (CABG) or laser holing. Exercise (EX), rest (RE) and intravenous infusion of nitroglycerine (NTG) SPECT 99 Tc m -MIBI myocardial imagings were performed before revascularization. Exercise and rest images revealed the myocardial ischemia. NTG images revealed myocardial viability. Culprit vessels were detected according to the defects showed by above mentioned images. The veracity of detected culprit vessels was tested with the outcome of the reperfusion therapy. Results: In this group, the coronary arteriography revealed 107 lesioned coronary arteries. Myocardial imaging detected 46 culprit vessels including 23 left anterior descending (LAD), 19 left circumflex coronary artery (LCX) and 4 right coronary artery (RCA). All 46 culprit vessels underwent revascularization and had nice outcome. The veracity of 99 Tc m -MIBI myocardial imaging detected culprit vessels was high according to patients' outcome. Conclusion: Exercise, rest and NTG 99 Tc m -MIBI myocardial imaging is a great method for detecting culprit vessels in multivessel coronary disease

  20. [Topography of the blood vessels in the hilum of the kidney of Myrmecophaga tridactyla].

    Science.gov (United States)

    Souza, W M; Miglino, M A; Arantes, I G; Nascimento, A A

    1991-01-01

    The study was undertaken in 10 formol-imbibed kidneys of great anteater (Myrmecophaga tridactyla). After the dissection the following characteristics were showed: kidney blood vessels are distributed in 2 different sites, namely hilar and extrahilar, amounting 3 to 6 in the right side 3 to 7 in the left side. Arterial branches in extrahilar region range from 1 to 2 in both sides and in hilar region they present from 1 to 4 in the right and 1 to 2 in the left. Venous roots occur in 1 to 2 vessels in the right and 1 to 3 vessels in the left, occupying only the hilar region, except one case where it was present in the right side.

  1. Non-Newtonian Mathematical Model and Numerical Simulations for the Blood Flow in Capillary Vessels

    Directory of Open Access Journals (Sweden)

    Balazs ALBERT

    2016-03-01

    Full Text Available In this paper, taking into consideration the rheological Cross type non-Newtonian model, we elaborate an axial-symmetric mathematical model for the blood flow in capillary vessel with adequate numeric algorithms. We take into account the elastic and porous behavior of the vessel wall which leads to a more realistic approach of the problem. We also accept that the change of substances through these vessels complies with the Starling hypothesis. This hypothesis states that the mass debit through the capillary wall is proportional to the pressure difference between outside and inside the capillaries. The existence of a slip condition along the permeable surface is also accepted using the results of Beavers and Joseph. The numerical experiments are made using COMSOL Multiphysics 3.3. Some numerical results with respect to the velocity field, pressure variation and the wall shear stress are presented.

  2. Blood vessel segmentation in modern wide-field retinal images in the presence of additive Gaussian noise.

    Science.gov (United States)

    Asem, Morteza Modarresi; Oveisi, Iman Sheikh; Janbozorgi, Mona

    2018-07-01

    Retinal blood vessels indicate some serious health ramifications, such as cardiovascular disease and stroke. Thanks to modern imaging technology, high-resolution images provide detailed information to help analyze retinal vascular features before symptoms associated with such conditions fully develop. Additionally, these retinal images can be used by ophthalmologists to facilitate diagnosis and the procedures of eye surgery. A fuzzy noise reduction algorithm was employed to enhance color images corrupted by Gaussian noise. The present paper proposes employing a contrast limited adaptive histogram equalization to enhance illumination and increase the contrast of retinal images captured from state-of-the-art cameras. Possessing directional properties, the multistructure elements method can lead to high-performance edge detection. Therefore, multistructure elements-based morphology operators are used to detect high-quality image ridges. Following this detection, the irrelevant ridges, which are not part of the vessel tree, were removed by morphological operators by reconstruction, attempting also to keep the thin vessels preserved. A combined method of connected components analysis (CCA) in conjunction with a thresholding approach was further used to identify the ridges that correspond to vessels. The application of CCA can yield higher efficiency when it is locally applied rather than applied on the whole image. The significance of our work lies in the way in which several methods are effectively combined and the originality of the database employed, making this work unique in the literature. Computer simulation results in wide-field retinal images with up to a 200-deg field of view are a testimony of the efficacy of the proposed approach, with an accuracy of 0.9524.

  3. [Imaging Blood Flow and Pulsation of Retinal Vessels with Full-Field Swept-Source OCT].

    Science.gov (United States)

    Spahr, H; Hillmann, D; Hain, C; Pfäffle, C; Sudkamp, H; Franke, G; Koch, P; Hüttmann, G

    2016-12-01

    Optical coherence tomography (OCT) uses interference to image the retina with high axial resolution. In the last 25 years, new technologies have permitted a steady increase in imaging speed, which made it possible to enlarge the imaged field and to avoid motion artefacts. The speed and precision of retinal imaging is now limited by photodamage of the retina caused by the focused OCT beam and by the speed of the scanning mechanics. Full-field swept-source (FF-SS)-OCT decreases irradiance on the retina and dispenses moving parts by using a camera to acquire the full volume of the retina in parallel. Here we show that FF-SS-OCT is rapid and precise enough to image pulsation in the retina induced by the heart beat. Series of OCT volumes 1.8 × 0.7 mm wide and 1.8 mm deep were recorded in young volunteers over a few cycles of the heart beat. Morphology of the retinal vessels, blood flow and tissue motion as caused by vessel pulsation were calculated from the OCT data. FF-SS-OCT was able to visualise the main structures of the neuronal retina, including vessels and small capillaries and without any motion artefacts. Information on three different dynamic processes was obtained from only one recorded series of OCT volumes: pulsation of blood flow and blood pressure in retinal vessels as well as pulsation of the choroid. Delays between arterial and venous pulse and delay between pulsation in retinal and choroidal vessels were calculated. With a time resolution of 0.5 ms, FF-SS-OCT is able to visualise previously unmeasurably fast changes in the retina, including the propagation of pulse waves. Georg Thieme Verlag KG Stuttgart · New York.

  4. Blood vessels pattern heparan sulfate gradients between their apical and basolateral aspects.

    Directory of Open Access Journals (Sweden)

    Liat Stoler-Barak

    Full Text Available A hallmark of immune cell trafficking is directional guidance via gradients of soluble or surface bound chemokines. Vascular endothelial cells produce, transport and deposit either their own chemokines or chemokines produced by the underlying stroma. Endothelial heparan sulfate (HS was suggested to be a critical scaffold for these chemokine pools, but it is unclear how steep chemokine gradients are sustained between the lumenal and ablumenal aspects of blood vessels. Addressing this question by semi-quantitative immunostaining of HS moieties around blood vessels with a pan anti-HS IgM mAb, we found a striking HS enrichment in the basal lamina of resting and inflamed post capillary skin venules, as well as in high endothelial venules (HEVs of lymph nodes. Staining of skin vessels with a glycocalyx probe further suggested that their lumenal glycocalyx contains much lower HS density than their basolateral extracellular matrix (ECM. This polarized HS pattern was observed also in isolated resting and inflamed microvascular dermal cells. Notably, progressive skin inflammation resulted in massive ECM deposition and in further HS enrichment around skin post capillary venules and their associated pericytes. Inflammation-dependent HS enrichment was not compromised in mice deficient in the main HS degrading enzyme, heparanase. Our results suggest that the blood vasculature patterns steep gradients of HS scaffolds between their lumenal and basolateral endothelial aspects, and that inflammatory processes can further enrich the HS content nearby inflamed vessels. We propose that chemokine gradients between the lumenal and ablumenal sides of vessels could be favored by these sharp HS scaffold gradients.

  5. A Strategy for Rapid Construction of Blood Vessel-Like Structures with Complex Cell Alignments.

    Science.gov (United States)

    Wang, Nuoxin; Peng, Yunhu; Zheng, Wenfu; Tang, Lixue; Cheng, Shiyu; Yang, Junchuan; Liu, Shaoqin; Zhang, Wei; Jiang, Xingyu

    2018-04-17

    A method is developed that can rapidly produce blood vessel-like structures by bonding cell-laden electrospinning (ES) films layer by layer using fibrin glue within 90 min. This strategy allows control of cell type, cell orientation, and material composition in separate layers. Furthermore, ES films with thicker fibers (polylactic-co-glycolic acid, fiber diameter: ≈3.7 µm) are used as cell-seeding layers to facilitate the cell in-growth; those with thinner fibers (polylactic acid, fiber diameter: ≈1.8 µm) are used as outer reinforcing layers to improve the mechanical strength and reduce the liquid leakage of the scaffold. Cells grow, proliferate, and migrate well in the multilayered structure. This design aims at a new type of blood vessel substitute with flexible control of parameters and implementation of functions. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Tight junction between endothelial cells: the interaction between nanoparticles and blood vessels

    Directory of Open Access Journals (Sweden)

    Yue Zhang

    2016-05-01

    Full Text Available Since nanoparticles are now widely applied as food additives, in cosmetics and other industries, especially in medical therapy and diagnosis, we ask here whether nanoparticles can cause several adverse effects to human health. In this review, based on research on nanotoxicity, we mainly discuss the negative influence of nanoparticles on blood vessels in several aspects and the potential mechanism for nanoparticles to penetrate endothelial layers of blood vessels, which are the sites of phosphorylation of tight junction proteins (claudins, occludins, and ZO (Zonula occludens proteins, oxidative stress and shear stress. We propose a connection between the presence of nanoparticles and the regulation of the tight junction, which might be the key approach for nanoparticles to penetrate endothelial layers and then have an impact on other tissues and organs.

  7. Electrospun Fibrous Scaffolds for Small-Diameter Blood Vessels: A Review

    Directory of Open Access Journals (Sweden)

    Nasser K. Awad

    2018-03-01

    Full Text Available Small-diameter blood vessels (SDBVs are still a challenging task to prepare due to the occurrence of thrombosis formation, intimal hyperplasia, and aneurysmal dilation. Electrospinning technique, as a promising tissue engineering approach, can fabricate polymer fibrous scaffolds that satisfy requirements on the construction of extracellular matrix (ECM of native blood vessel and promote the adhesion, proliferation, and growth of cells. In this review, we summarize the polymers that are deployed for the fabrication of SDBVs and classify them into three categories, synthetic polymers, natural polymers, and hybrid polymers. Furthermore, the biomechanical properties and the biological activities of the electrospun SBVs including anti-thrombogenic ability and cell response are discussed. Polymer blends seem to be a strategic way to fabricate SDBVs because it combines both suitable biomechanical properties coming from synthetic polymers and favorable sites to cell attachment coming from natural polymers.

  8. A SURVEY OF RETINA BASED DISEASE IDENTIFICATION USING BLOOD VESSEL SEGMENTATION

    Directory of Open Access Journals (Sweden)

    P Kuppusamy

    2016-11-01

    Full Text Available The colour retinal photography is one of the most essential features to identify the confirmation of various eye diseases. The iris is primary attribute to authenticate the human. This research work presents the survey and comparison of various blood vessel related feature identification, segmentation, extraction and enhancement methods. Additionally, this study is observed the various databases performance for storing the images and testing in minimal time. This paper is also provides the better performance techniques based on the survey.

  9. Heat as a contrast agent to enhance thermal imaging of blood vessels

    Science.gov (United States)

    Case, Jason R.; Trammell, Susan R.; Young, Madison A.; Israel, Uriah; Crown, Michael X.

    2013-03-01

    In this study we test the feasibility of using low-cost LEDs to selectivity heat blood for enhanced thermal imaging of vascular structures. Applications of this new imaging technique include mapping blood vessels during surgeries such as tumor removal and vascular repair. In addition, this technique could potentially be used to determine the location of increased vascular density, and thus breast cancer tumors. Porcine blood, skeletal muscle, skin and fat were illuminated with LEDs that emit at 405 nm and 530 nm (near the blood absorption peaks) and the increase in temperature as a function of time was recorded using a thermal camera. In the studies with the 530 nm LED, blood heated more than other tissue types and the heating rate for the blood was significantly faster than other tissues. Illumination of blood with the 530 nm LED at low powers (tissue irradiance tissue. Illumination with the 405 nm LED produced large temperature changes (up to 15°C) at low LED powers (tissue irradiance muscle tissue was dependent on the skeletal muscle type, but most samples showed heating comparable to or larger than blood. This LED was not effective at selectively heating blood relative to the other tissue types. The results of the preliminary studies suggest that the best contrast can be achieved with pulsed 530 nm LED illumination and an image analysis method that highlights rapid changes in temperature.

  10. [Do double gloves protect against contamination during cannulation of blood vessels? A prospective randomized study].

    Science.gov (United States)

    Szarpak, Łukasz; Kurowski, Andrzej

    2014-01-01

    Undamaged medical gloves protect medical personnel from contact with physiological fluids of the patient. Thus they protect the assistance provider from hand skin contamination with potentially infectious biological materials. The aim of the study was to evaluate the occurrence of pierce, perforations or damage of medical gloves during cannulation of blood vessels. In the prospective randomized study 303 pairs of gloves, used during cannulation of blood vessels under simulated resuscitation, were analyzed. Gloves were tested by the water leak test. The water test revealed 44 cases of damage to the gloves used during cannulation of blood vessels. Significant differences were noted in the frequency of damage to both the outer and single pairs of gloves and the inner pair of gloves. The study showed that the use of double gloves provides a higher level of security for a paramedic than the use of a single pair of gloves, however, double gloves reduce the manual dexterity of a paramedic. A large number of damages to gloves are not noticed by medical personnel during surgery.

  11. Effect of Electrical Stimulation on Blood Flow Velocity and Vessel Size

    Science.gov (United States)

    Jin, Hee-Kyung; Hwang, Tae-Yeon; Cho, Sung-Hyoun

    2017-01-01

    Abstract Interferential current electrical stimulation alters blood flow velocity and vessel size. We aimed to investigate the changes in the autonomic nervous system depending on electrical stimulation parameters. Forty-five healthy adult male and female subjects were studied. Bipolar adhesive pad electrodes were used to stimulate the autonomic nervous system at the thoracic vertebrae 1-4 levels for 20 min. Using Doppler ultrasonography, blood flow was measured to determine velocity and vessel size before, immediately after, and 30 min after electrical stimulation. Changes in blood flow velocity were significantly different immediately and 30 min after stimulation. The interaction between intervention periods and groups was significantly different between the exercise and pain stimulation groups immediately after stimulation (p<0.05). The vessel size was significantly different before and 30 min after stimulation (p<0.05). Imbalances in the sympathetic nervous system, which regulates balance throughout the body, may present with various symptoms. Therefore, in the clinical practice, the parameters of electrical stimulation should be selectively applied in accordance with various conditions and changes in form. PMID:28401194

  12. Promoting blood vessel growth in ischemic diseases: challenges in translating preclinical potential into clinical success

    Directory of Open Access Journals (Sweden)

    Galina Dragneva

    2013-03-01

    Full Text Available Angiogenic therapy, which involves the use of an exogenous stimulus to promote blood vessel growth, is an attractive approach for the treatment of ischemic diseases. It has been shown in animal models that the stimulation of blood vessel growth leads to the growth of the whole vascular tree, improvement of ischemic tissue perfusion and improved muscle aerobic energy metabolism. However, very few positive results have been gained from Phase 2 and 3 clinical angiogenesis trials. Many reasons have been given for the failures of clinical trials, including poor transgene expression (in gene-therapy trials and instability of the vessels induced by therapy. In this Review, we discuss the selection of preclinical models as one of the main reasons why clinical translation has been unsuccessful thus far. This issue has received little attention, but could have had dramatic implications on the expectations of clinical trials. We highlight crucial differences between human patients and animal models with regards to blood flow and pressure, as well as issues concerning the chronic nature of ischemic diseases in humans. We use these as examples to demonstrate why the results from preclinical trials might have overestimated the efficacy of angiogenic therapies developed to date. We also suggest ways in which currently available animal models of ischemic disease could be improved to better mimic human disease conditions, and offer advice on how to work with existing models to avoid overestimating the efficacy of new angiogenic therapies.

  13. Effect of Electrical Stimulation on Blood Flow Velocity and Vessel Size.

    Science.gov (United States)

    Jin, Hee-Kyung; Hwang, Tae-Yeon; Cho, Sung-Hyoun

    2017-01-01

    Interferential current electrical stimulation alters blood flow velocity and vessel size. We aimed to investigate the changes in the autonomic nervous system depending on electrical stimulation parameters. Forty-five healthy adult male and female subjects were studied. Bipolar adhesive pad electrodes were used to stimulate the autonomic nervous system at the thoracic vertebrae 1-4 levels for 20 min. Using Doppler ultrasonography, blood flow was measured to determine velocity and vessel size before, immediately after, and 30 min after electrical stimulation. Changes in blood flow velocity were significantly different immediately and 30 min after stimulation. The interaction between intervention periods and groups was significantly different between the exercise and pain stimulation groups immediately after stimulation (p<0.05). The vessel size was significantly different before and 30 min after stimulation (p<0.05). Imbalances in the sympathetic nervous system, which regulates balance throughout the body, may present with various symptoms. Therefore, in the clinical practice, the parameters of electrical stimulation should be selectively applied in accordance with various conditions and changes in form.

  14. Dual-body magnetic helical robot for drilling and cargo delivery in human blood vessels

    Science.gov (United States)

    Lee, Wonseo; Jeon, Seungmun; Nam, Jaekwang; Jang, Gunhee

    2015-05-01

    We propose a novel dual-body magnetic helical robot (DMHR) manipulated by a magnetic navigation system. The proposed DMHR can generate helical motions to navigate in human blood vessels and to drill blood clots by an external rotating magnetic field. It can also generate release motions which are relative rotational motions between dual-bodies to release the carrying cargos to a target region by controlling the magnitude of an external magnetic field. Constraint equations were derived to selectively manipulate helical and release motions by controlling external magnetic fields. The DMHR was prototyped and various experiments were conducted to demonstrate its motions and verify its manipulation methods.

  15. Note: Reflection-type micro multipoint laser Doppler velocimeter for measuring velocity distributions in blood vessels.

    Science.gov (United States)

    Ishida, H; Kobayashi, D; Shirakawa, H; Andoh, T; Akiguchi, S; Wakisaka, T; Ishizuka, M; Hachiga, T

    2011-07-01

    We have developed a laser Doppler velocimeter (LDV) for measuring velocity distributions in blood vessels. We converted a transmission-based LDV into a reflection-based LDV to make it suitable for clinical applications. The velocity distribution image of a serpentine flow channel obtained could be qualitatively explained by the numerical results. Finally, we evaluated the system by using it to measure injection of blood into a glass tube by a syringe pump. The results obtained demonstrate that erythrocytes can be used as seeding particles for the reflection-type micro multipoint LDV. The results obtained are useful as basic data for clinical applications.

  16. Blood clot detection using magnetic nanoparticles

    Science.gov (United States)

    Khurshid, Hafsa; Friedman, Bruce; Berwin, Brent; Shi, Yipeng; Ness, Dylan B.; Weaver, John B.

    2017-05-01

    Deep vein thrombosis, the development of blood clots in the peripheral veins, is a very serious, life threatening condition that is prevalent in the elderly. To deliver proper treatment that enhances the survival rate, it is very important to detect thrombi early and at the point of care. We explored the ability of magnetic particle spectroscopy (MSB) to detect thrombus via specific binding of aptamer functionalized magnetic nanoparticles with the blood clot. MSB uses the harmonics produced by nanoparticles in an alternating magnetic field to measure the rotational freedom and, therefore, the bound state of the nanoparticles. The nanoparticles' relaxation time for Brownian rotation increases when bound [A.M. Rauwerdink and J. B. Weaver, Appl. Phys. Lett. 96, 1 (2010)]. The relaxation time can therefore be used to characterize the nanoparticle binding to thrombin in the blood clot. For longer relaxation times, the approach to saturation is more gradual reducing the higher harmonics and the harmonic ratio. The harmonic ratios of nanoparticles conjugated with anti-thrombin aptamers (ATP) decrease significantly over time with blood clot present in the sample medium, compared with nanoparticles without ATP. Moreover, the blood clot removed from the sample medium produced a significant MSB signal, indicating the nanoparticles are immobilized on the clot. Our results show that MSB could be a very useful non-invasive, quick tool to detect blood clots at the point of care so proper treatment can be used to reduce the risks inherent in deep vein thrombosis.

  17. Microstructured Blood Vessel Surrogates Reveal Structural Tropism of Motile Malaria Parasites.

    Science.gov (United States)

    Muthinja, Mendi J; Ripp, Johanna; Hellmann, Janina K; Haraszti, Tamas; Dahan, Noa; Lemgruber, Leandro; Battista, Anna; Schütz, Lucas; Fackler, Oliver T; Schwarz, Ulrich S; Spatz, Joachim P; Frischknecht, Friedrich

    2017-03-01

    Plasmodium sporozoites, the highly motile forms of the malaria parasite, are transmitted naturally by mosquitoes and traverse the skin to find, associate with, and enter blood capillaries. Research aimed at understanding how sporozoites select blood vessels is hampered by the lack of a suitable experimental system. Arrays of uniform cylindrical pillars can be used to study small cells moving in controlled environments. Here, an array system displaying a variety of pillars with different diameters and shapes is developed in order to investigate how Plasmodium sporozoites associate to the pillars as blood vessel surrogates. Investigating the association of sporozoites to pillars in arrays displaying pillars of different diameters reveals that the crescent-shaped parasites prefer to associate with and migrate around pillars with a similar curvature. This suggests that after transmission by a mosquito, malaria parasites may use a structural tropism to recognize blood capillaries in the dermis in order to gain access to the blood stream. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. The Emergence of Blood and Blood Vessels in the Embryo and Its Relevance to Postnatal Biology and Disease

    Science.gov (United States)

    Sills, Tiffany M.; Hirschi, Karen K.

    Blood and blood vessels develop in parallel within mammalian systems, and this temporal and spatial association has led to the confirmation of an endothelial origin of hematopoiesis. The extraembryonic yolk sac and aorto-gonado-mesonephros (AGM) region both contain a specialized population of endothelial cells ("hemogenic endothelium") that function to produce hematopoietic stem and progenitor cells, which then differentiate to provide the full complement of blood cells within the developing embryo and furthermore in the adult system. Therefore, this population has great therapeutic potential in the fields of regenerative medicine and tissue engineering. This chapter reviews the development of the vascular and hematopoietic systems, characterization and function of the hemogenic endothelium within embryonic and embryonic stem cell (ES cell) models, and speculate on the presence of such a population within the adult system. In order to harness this endothelial subtype for clinical application, we must understand both the normal functions of these cells and the potential for misregulation in disease states.

  19. An Experimental Study to Replace the Thoracic Descending Aorta for Pigs with a Self-Made Sutureless Blood Vessel

    Directory of Open Access Journals (Sweden)

    Fenglin Song

    2014-01-01

    Full Text Available To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we carried thoracic descending aorta replacement using either SMSBV or Gore-Tex, respectively, in pigs. The aortic clamp time and the operative blood loss in the experimental group (using SMSBV were less than those in the control group (using Gore-Tex. The whole blood hematocrit, platelet count, plasma soluble P-selectin, plasma free hemoglobin, and interleukins 2, 6 at each time point were not different significantly between the two groups. Light microscopy and transmission electron microscopy examination showed there were layers of vascular smooth muscle cells and endothelial cells adhered in the inner wall of artificial blood vessel without any signs of thrombosis. Based on the result, we have drawn the conclusion that the application of SMSBV can significantly shorten the vascular anastomosis time, reduce operative blood loss, and show good blood and tissue compatibility.

  20. An Experimental Study to Replace the Thoracic Descending Aorta for Pigs with a Self-Made Sutureless Blood Vessel

    Science.gov (United States)

    Song, Fenglin; Zhou, Wenwu; Tang, Tao; Li, Xiaobing; Wu, Xiaoming; Yang, Jinfu

    2014-01-01

    To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV) was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we carried thoracic descending aorta replacement using either SMSBV or Gore-Tex, respectively, in pigs. The aortic clamp time and the operative blood loss in the experimental group (using SMSBV) were less than those in the control group (using Gore-Tex). The whole blood hematocrit, platelet count, plasma soluble P-selectin, plasma free hemoglobin, and interleukins 2, 6 at each time point were not different significantly between the two groups. Light microscopy and transmission electron microscopy examination showed there were layers of vascular smooth muscle cells and endothelial cells adhered in the inner wall of artificial blood vessel without any signs of thrombosis. Based on the result, we have drawn the conclusion that the application of SMSBV can significantly shorten the vascular anastomosis time, reduce operative blood loss, and show good blood and tissue compatibility. PMID:24696856

  1. An experimental study to replace the thoracic descending aorta for pigs with a self-made sutureless blood vessel.

    Science.gov (United States)

    Song, Fenglin; Zhou, Wenwu; Tang, Tao; Li, Xiaobing; Wu, Xiaoming; Yang, Jinfu

    2014-01-01

    To simplify the procedure of blood vessel replacement operation and shorten the vascular anastomosis time, we developed a special artificial blood vessel which can be connected to native blood vessels without suture. The self-made sutureless blood vessel (SMSBV) was made from two titanium connectors and a Gore-Tex graft. To investigate blood compatibility and histocompatibility of the SMSBV, we carried thoracic descending aorta replacement using either SMSBV or Gore-Tex, respectively, in pigs. The aortic clamp time and the operative blood loss in the experimental group (using SMSBV) were less than those in the control group (using Gore-Tex). The whole blood hematocrit, platelet count, plasma soluble P-selectin, plasma free hemoglobin, and interleukins 2, 6 at each time point were not different significantly between the two groups. Light microscopy and transmission electron microscopy examination showed there were layers of vascular smooth muscle cells and endothelial cells adhered in the inner wall of artificial blood vessel without any signs of thrombosis. Based on the result, we have drawn the conclusion that the application of SMSBV can significantly shorten the vascular anastomosis time, reduce operative blood loss, and show good blood and tissue compatibility.

  2. Adaptable three-dimensional Monte Carlo modeling of imaged blood vessels in skin

    Science.gov (United States)

    Pfefer, T. Joshua; Barton, Jennifer K.; Chan, Eric K.; Ducros, Mathieu G.; Sorg, Brian S.; Milner, Thomas E.; Nelson, J. Stuart; Welch, Ashley J.

    1997-06-01

    In order to reach a higher level of accuracy in simulation of port wine stain treatment, we propose to discard the typical layered geometry and cylindrical blood vessel assumptions made in optical models and use imaging techniques to define actual tissue geometry. Two main additions to the typical 3D, weighted photon, variable step size Monte Carlo routine were necessary to achieve this goal. First, optical low coherence reflectometry (OLCR) images of rat skin were used to specify a 3D material array, with each entry assigned a label to represent the type of tissue in that particular voxel. Second, the Monte Carlo algorithm was altered so that when a photon crosses into a new voxel, the remaining path length is recalculated using the new optical properties, as specified by the material array. The model has shown good agreement with data from the literature. Monte Carlo simulations using OLCR images of asymmetrically curved blood vessels show various effects such as shading, scattering-induced peaks at vessel surfaces, and directionality-induced gradients in energy deposition. In conclusion, this augmentation of the Monte Carlo method can accurately simulate light transport for a wide variety of nonhomogeneous tissue geometries.

  3. A simply prepared small-diameter artificial blood vessel that promotes in situ endothelialization.

    Science.gov (United States)

    Guo, Hong-Feng; Dai, Wei-Wei; Qian, De-Hui; Qin, Zhe-Xue; Lei, Yan; Hou, Xiao-Yu; Wen, Can

    2017-05-01

    Synthetic grafts are of limited use in small-diameter vessels (Φartificial blood vessels with the aim of facilitating early endothelialization and improving long-term patency. STATEMENT OF SIGNIFICANCE: (1) SDF-1α/VEGF loaded PU conduits were simply prepared by electrospinning. The cytokines with definite and potent effects on angiogenesis were used to avoid complicated mechanism researches. Compared with most of the current vascular grafts which are of poor strength or elasticity, the conduits have favorable mechanical property. All of these inhibit the conduits from occlusion, and thus improve their long-term patency rate. (2) For the in vivo tests, the dogs did not receive any anticoagulant medication in the follow-up period to expose the grafts to the strictest conditions. In vivo endothelialization of the conduits was thoroughly investigated by Sonography, HE staining, SEM and LSCM. The study will be helpful for the construction of small-diameter artificial blood vessels. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. Blood Vessel Extraction in Color Retinal Fundus Images with Enhancement Filtering and Unsupervised Classification

    Directory of Open Access Journals (Sweden)

    Zafer Yavuz

    2017-01-01

    Full Text Available Retinal blood vessels have a significant role in the diagnosis and treatment of various retinal diseases such as diabetic retinopathy, glaucoma, arteriosclerosis, and hypertension. For this reason, retinal vasculature extraction is important in order to help specialists for the diagnosis and treatment of systematic diseases. In this paper, a novel approach is developed to extract retinal blood vessel network. Our method comprises four stages: (1 preprocessing stage in order to prepare dataset for segmentation; (2 an enhancement procedure including Gabor, Frangi, and Gauss filters obtained separately before a top-hat transform; (3 a hard and soft clustering stage which includes K-means and Fuzzy C-means (FCM in order to get binary vessel map; and (4 a postprocessing step which removes falsely segmented isolated regions. The method is tested on color retinal images obtained from STARE and DRIVE databases which are available online. As a result, Gabor filter followed by K-means clustering method achieves 95.94% and 95.71% of accuracy for STARE and DRIVE databases, respectively, which are acceptable for diagnosis systems.

  5. High Endothelial Venules and Other Blood Vessels: Critical Regulators of Lymphoid Organ Development and Function

    Science.gov (United States)

    Ager, Ann

    2017-01-01

    The blood vasculature regulates both the development and function of secondary lymphoid organs by providing a portal for entry of hemopoietic cells. During the development of lymphoid organs in the embryo, blood vessels deliver lymphoid tissue inducer cells that initiate and sustain the development of lymphoid tissues. In adults, the blood vessels are structurally distinct from those in other organs due to the requirement for high levels of lymphocyte recruitment under non-inflammatory conditions. In lymph nodes (LNs) and Peyer’s patches, high endothelial venules (HEVs) especially adapted for lymphocyte trafficking form a spatially organized network of blood vessels, which controls both the type of lymphocyte and the site of entry into lymphoid tissues. Uniquely, HEVs express vascular addressins that regulate lymphocyte entry into lymphoid organs and are, therefore, critical to the function of lymphoid organs. Recent studies have demonstrated important roles for CD11c+ dendritic cells in the induction, as well as the maintenance, of vascular addressin expression and, therefore, the function of HEVs. Tertiary lymphoid organs (TLOs) are HEV containing LN-like structures that develop inside organized tissues undergoing chronic immune-mediated inflammation. In autoimmune lesions, the development of TLOs is thought to exacerbate disease. In cancerous tissues, the development of HEVs and TLOs is associated with improved patient outcomes in several cancers. Therefore, it is important to understand what drives the development of HEVs and TLOs and how these structures contribute to pathology. In several human diseases and experimental animal models of chronic inflammation, there are some similarities between the development and function of HEVs within LN and TLOs. This review will summarize current knowledge of how hemopoietic cells with lymphoid tissue-inducing, HEV-inducing, and HEV-maintaining properties are recruited from the bloodstream to induce the development and

  6. Comparison between PVHIS on the MRI and the permeability of brain blood vessels in elderly patients

    International Nuclear Information System (INIS)

    Yamaguchi, Katsuhiko; Tanaka, Yuriko; Kubo, Hideki; Takagi, Yasushi; Tachikawa, Shinzo; Katsunuma, Hideyo.

    1989-01-01

    The degree of PVHIS (periventricular high intensity signal) on the MRI was composed with the permeability of brain blood vessels using the cerebrospinal fluid (CSF)/serum ratio for albumin, and the CSF/serum ratio for IgG in elderly patients. The 47 elderly patients (mean age=79.9) were divided into three groups: (1) Mild group (20 cases, M:6, F:14, mean age=75.8), (2) Moderate group (18 cases, M:7, F:11, mean age=82.6), (3) Severe group (9 cases, M:2, F:7, mean age=82.9), in accordance with the degree of PVHIS on the MRI. The MRI was operated at a field strength of 0.22 tesla. The pulse sequence (used on all patients) had a repetition times (TR) of 2,000 msec and a time to echo (TE) of 40 msec. The levels of albumin and IgG in the serum and CSF were measured. The CSF/serum ratio for albumin was used of analyze the permeability of the brain blood vessels in each group. There was no significant difference in the level of the serum albumin, the CSF albumin, the serum IgG, the CSF IgG and the CSF/serum ratio for IgG among the three groups. The same was found to be true for the IgG index which indicates the synthesis of immunoglobulin in the central nervous system. However, there was a statistically significant difference (p<0.05) in the CSF/serum ratio for albumin between groups (1) and (3). The increased CSF/serum ratio for albumin in the severe group indicated there were confluent lesions involving the entire extent of the periventriular white matter on the MRI. This suggested an increased permeability of brain blood vessels which revealed the dysfunction of the blood brain barrier due to affected cerebral endothelial cells in capillaries. (author)

  7. Synthetic reconstruction of dynamic blood flow in cortical arteries using optical coherence tomography for the evaluation of vessel compliance

    Science.gov (United States)

    Baraghis, Edward; Bolduc, Virginie; Gillis, Marc-Antoine; Srinivasan, Vivek J.; Thorin, Éric; Boudoux, Caroline; Lesage, Frédéric

    2011-03-01

    Optical Coherence Tomography (OCT) has recently been used to produce 3D angiography of microvasculature in the rodent brain in-vivo and blood flow maps of large vessels. Key enabling developments were novel algorithms for detecting Doppler shifts produced by moving scatterers and new scanning protocols tailored to increase sensitivity to small flow speeds. These progresses were pushed by the need for a non invasive imaging modality to monitor quantitative blood flow at a higher resolution and a greater depth than could be achieved by other means. The rationale for this work originates from new hypotheses regarding the role of blood regulation in neurodegenerative diseases and from current investigations of animal models of vascular degeneration. In this work we demonstrate the synthetic reconstruction of dynamic blood flow in mice over the course of a single cardiac cycle in an 800μm wide by ~ 3mm deep B-Frame slice with a lateral resolution of 10μm and a depth resolution of 7μm. Images were taken using a cranial window over the exposed parietal bone of mice skull. Electrocardiography (ECG) recordings were co registered with the OCT A lines at high temporal resolution. QRS peak detection was then used to locate the time value of each A-line in the cardiac cycle and to reconstruct a synthetic temporal frame over one cardiac cycle. Doppler speed in this cardiac cycle was used to measure temporal variations of flow inside arteries and of their area. Three dimensional volume scans yielded measurements of quantitative blood flow on the same arteries. Using these informations a measure of compliance could be established. Comparing measures between atherosclerotic (ATX) and wild type (WT) mice revealed higher blood flow in WT mice, suggested lower systemic compliance in the ATX group but higher compliance of cerebral vasculature on these mice. These results are consistent with expectations showing that OCT is a potential tool for in-vivo arterial compliance evaluation.

  8. Mathematical Models and Numerical Simulations for the Blood Flow in Large Vessels

    Directory of Open Access Journals (Sweden)

    Titus PETRILA

    2012-12-01

    Full Text Available We are proposing a non-Newtonian, Cross type rheological model for the blood flow, under the conditions of an unsteady flow regime connected with the rhythmic pumping of the blood by the heart. We admit the incompressibility and homogeneity of the blood while its flow is laminar and the exterior body forces are neglected. We take also into account the viscoelastic behavior of the vessel walls. The mathematical equations and the appropriate boundary conditions are considered in cylindrical (axisymmetric coordinates. Numerical experiments in case of stenosed artery and in artery with aneurysm (using COMSOL Multiphysics 3.3 are made. The variation of the wall shear stress, which is believed to have a special importance in the rupture of aneurysms, is calculated using both a Newtonian and a non-Newtonian model.

  9. Brain Blood Vessel Map Extraction Using Wavelet-based DSA Fusion

    Directory of Open Access Journals (Sweden)

    Saba Momeni

    2013-10-01

    Full Text Available Recently image fusion has prominent and applicable roles in medical image processing. Digital subtraction angiography (DSA image is applied to display map of blood vessels. In this essay, a new fusion algorithm for DSA serial images based on discrete wavelet transform coefficients is proposed. Fusion of high frequency coefficients is based on proposed fusion map and four evaluation criteria which introduce level of coefficient's energy. Our algorithm will be compared for different wavelet transforms and activity criteria for high frequency coefficients. The comparisons are based on the objective evaluation criteria which show measure of noise existence, sharpness and correlation between the fusion result and reference image. Finally, Meyer discrete wavelet transform is resulted as the best wavelet transform, and sum of modified Laplacian, local energy are introduced as activity level measurment for high and low frequency coefficients in process of brain vessel map extraction.

  10. Utilizing the Foreign Body Response to Grow Tissue Engineered Blood Vessels in Vivo.

    Science.gov (United States)

    Geelhoed, Wouter J; Moroni, Lorenzo; Rotmans, Joris I

    2017-04-01

    It is well known that the number of patients requiring a vascular grafts for use as vessel replacement in cardiovascular diseases, or as vascular access site for hemodialysis is ever increasing. The development of tissue engineered blood vessels (TEBV's) is a promising method to meet this increasing demand vascular grafts, without having to rely on poorly performing synthetic options such as polytetrafluoroethylene (PTFE) or Dacron. The generation of in vivo TEBV's involves utilizing the host reaction to an implanted biomaterial for the generation of completely autologous tissues. Essentially this approach to the development of TEBV's makes use of the foreign body response to biomaterials for the construction of the entire vascular replacement tissue within the patient's own body. In this review we will discuss the method of developing in vivo TEBV's, and debate the approaches of several research groups that have implemented this method.

  11. [Molecular mechanism for the establishment of blood-vessel gateway for immune cells in the CNS.

    Science.gov (United States)

    Murakami, Masaaki

    We have been studying about the molecular mechanism responsible for the establishment of the blood-vessel gateway through which immune cells enter the CNS. We have discovered three kinds of gateways in a multiple sclerosis model, EAE, based on the neural stimulations and named them the gravity-gateway reflex, electric-gateway reflex, and pain-gateway reflex, respectively. All gateway reflexes are involved in specific crosstalk between sensory-sympathetic pathways. For example, in the gravity-gateway reflex, gravity-mediated sensory stimulation via the soleus muscles activates fifth lumber(L5)dorsal loot ganglions to activate L5 sympathetic ganglions, which express norepinephrine at specific vessels of the L5 cord. We explain these three types of gateway reflexes in this chapter.

  12. Understanding How Space Travel Affects Blood Vessels: Arterial Remodeling and Functional Adaptations Induced by Microgravity

    Science.gov (United States)

    Delp, Michael; Vasques, Marilyn; Aquilina, Rudy (Technical Monitor)

    2002-01-01

    Ever rise quickly from the couch to get something from the kitchen and suddenly feel dizzy? With a low heart rate and relaxed muscles, the cardiovascular system does not immediately provide the resistance necessary to keep enough blood going to your head. Gravity wins, at least for a short time, before your heart and blood vessels can respond to the sudden change in position and correct the situation. Actually, the human cardiovascular system is quite well adapted to the constant gravitational force of the Earth. When standing, vessels in the legs constrict to prevent blood from collecting in the lower extremities. In the space environment, the usual head-to-foot blood pressure and tissue fluid gradients that exist during the upright posture on Earth are removed. The subsequent shift in fluids from the lower to the upper portions of the body triggers adaptations within the cardiovascular system to accommodate the new pressure and fluid gradients. In animal models that simulate microgravity, the vessels in the head become more robust while those in the lower limbs become thin and lax. Similar changes may also occur in humans during spaceflight and while these adaptations are appropriate for a microgravity environment, they can cause problems when the astronauts return to Earth or perhaps another planet. Astronauts often develop orthostatic intolerance which means they become dizzy or faint when standing upright. This dizziness can persist for a number of days making routine activities difficult. In an effort to understand the physiological details of these cardiovascular adaptations, Dr. Michael Delp at Texas A&M University, uses the rat as a model for his studies. For the experiment flown on STS-107, he will test the hypothesis that blood vessels in the rats' hindlimbs become thinner, weaker, and constrict less in response to pressure changes and to chemical signals when exposed to microgravity. In addition, he will test the hypothesis that arteries in the brain

  13. Automatic blood detection in capsule endoscopy video

    Science.gov (United States)

    Novozámský, Adam; Flusser, Jan; Tachecí, Ilja; Sulík, Lukáš; Bureš, Jan; Krejcar, Ondřej

    2016-12-01

    We propose two automatic methods for detecting bleeding in wireless capsule endoscopy videos of the small intestine. The first one uses solely the color information, whereas the second one incorporates the assumptions about the blood spot shape and size. The original idea is namely the definition of a new color space that provides good separability of blood pixels and intestinal wall. Both methods can be applied either individually or their results can be fused together for the final decision. We evaluate their individual performance and various fusion rules on real data, manually annotated by an endoscopist.

  14. Near Real-Time Automatic Marine Vessel Detection on Optical Satellite Images

    Science.gov (United States)

    Máttyus, G.

    2013-05-01

    Vessel monitoring and surveillance is important for maritime safety and security, environment protection and border control. Ship monitoring systems based on Synthetic-aperture Radar (SAR) satellite images are operational. On SAR images the ships made of metal with sharp edges appear as bright dots and edges, therefore they can be well distinguished from the water. Since the radar is independent from the sun light and can acquire images also by cloudy weather and rain, it provides a reliable service. Vessel detection from spaceborne optical images (VDSOI) can extend the SAR based systems by providing more frequent revisit times and overcoming some drawbacks of the SAR images (e.g. lower spatial resolution, difficult human interpretation). Optical satellite images (OSI) can have a higher spatial resolution thus enabling the detection of smaller vessels and enhancing the vessel type classification. The human interpretation of an optical image is also easier than as of SAR image. In this paper I present a rapid automatic vessel detection method which uses pattern recognition methods, originally developed in the computer vision field. In the first step I train a binary classifier from image samples of vessels and background. The classifier uses simple features which can be calculated very fast. For the detection the classifier is slided along the image in various directions and scales. The detector has a cascade structure which rejects most of the background in the early stages which leads to faster execution. The detections are grouped together to avoid multiple detections. Finally the position, size(i.e. length and width) and heading of the vessels is extracted from the contours of the vessel. The presented method is parallelized, thus it runs fast (in minutes for 16000 × 16000 pixels image) on a multicore computer, enabling near real-time applications, e.g. one hour from image acquisition to end user.

  15. Control of weft yarn or density improves biocompatibility of PET small diameter artificial blood vessels.

    Science.gov (United States)

    Hu, Xingyou; Hu, Tao; Guan, Guoping; Yu, Shaoting; Wu, Yufen; Wang, Lu

    2018-04-01

    Polyethylene glycol terephthalate (PET) fabrics with woven structures have proved to be quite effective for use on large diameter artificial blood vessels. However, their use within small-diameter artificial blood vessels has been associated with poor long-term patency, a problem resulting from slow endothelialization on PET and an over hyperplasia of smooth muscle cells. Previous research from our laboratory has revealed that ICAM-1 can be used as a marker to investigate cell adhesion, an effect which was closely associated with cell behavior on the surface of polycaprolactone (PCL) films. Moreover, we found that the coarseness or pore size of the surface exerts considerable influence on cell adhesion and proliferation on PCL films. In this study, we successfully fabricated six types of PET woven fabrics with varying gradients of tightness and porosities. Levels of ICAM-1 expression (membrane ICAM-1 & soluble ICAM-1) were then determined in these woven fabrics. Our results show that increased levels of mICAM-1 and decreased levels of sICAM-1 expression were obtained in HUVECs seeded on these six samples. These findings indicate that cell adhesion and proliferation on fabric surfaces were strongly influenced by their structural parameters, in particular the initial adhesion between the cell and fabric surface. In addition, we also found that extracellular matrix adhesion tends to prefer flat and tight surfaces, which promotes cell-cell and cell-matrix interactions, as well as the endothelialization on the surface of PET fabrics. These findings provide some novel insights with regard to the design and application of small-diameter artificial blood vessels. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 954-964, 2018. © 2017 Wiley Periodicals, Inc.

  16. A new model for the artificial aorta blood vessels using double-sided radial functionally graded biomaterials.

    Science.gov (United States)

    Salimi Bani, M; Asgharzadeh Shirazi, H; Ayatollahi, M R; Asnafi, Alireza

    2017-05-01

    Based on radial functionally graded biomaterials and inspired by the geometry of a real aorta blood vessel, a new model was proposed to fabricate the artificial blood vessels. A finite element analyzer is employed to reach the optimal and proper material properties while earlier, it was validated by two famous theories, i.e., the first shear deformation and the plane elasticity. First, the geometry of a real ascending aorta part was simulated and then solved under the axially varying blood pressure and other real and actual conditions. Since the construction of artificial blood vessels just similar to the natural one is impossible, it was tried to find the best substitutes for other materials. Due to the significant properties of functionally graded biomaterials in the reduction in sudden changes of stress and deformation, these types of materials were selected and studied. Two types of conventional single-sided and an efficient double-sided radial functionally graded vessel were proposed and simulated. The elastic behaviors of proposed vessels were obtained and compared to ones previously attained from the real vessel. The results show that all the desired behaviors cannot be achieved by using a conventional single-sided radial FG vessel. Instead and as a conjecture, a smart double-sided radial FG biomaterial is suggested. Fortunately, the proposed material can meet all the desired goals and satisfy all of the indices simultaneously.

  17. Evaluation of detectable defect size for inner defect of pressure vessel using laser speckle

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyeoung Suk; Seon, Sang Woo; Choi, Tae Ho; Kang, Chan Geun; Na, Man Gyun; Jung, Hyun Chul [Chsoun University, Gwangju (Korea, Republic of)

    2014-04-15

    Pressure vessels are used in various industrial fields. If a defect occurs on the inner or outer surface of a pressure vessel, it may cause a massive accident. A defect on the outer surface can be detected by visual inspection. However, a defect on the inner surface is generally impossible to detect with visual inspection. Nondestructive testing can be used to detect this type of defect. Laser speckle shearing interferometry is one nondestructive testing method that can optically detect a defect; its advantages include noncontact, full field, and real time inspection. This study evaluated the detectable size for an internal defect of a pressure vessel. The material of the pressure vessel was ASTM A53 Gr.B. The internal defect was detected when the pressure vessel was loaded by internal pressure controlled by a pneumatic system. The internal pressure was controlled from 0.2 MPa to 0.6 MPa in increments of 0.2 MPa. The results confirmed that an internal defect with a 25 % defect depth could be detected even at 0.2 MPa pressure variation.

  18. Design and development of a blood vessel localization system using a Nir viewer

    International Nuclear Information System (INIS)

    Hernandez R, A.; Plascencia C, L. E.; Cordova F, T.; Padilla R, N.

    2017-10-01

    In addition to the multiple applications of ionizing radiation in clinical diagnosis there is the possibility of using another part of the electromagnetic spectrum such as near infrared (Nir). This paper presents the design and construction of a Nir Biosensor in a range between 800 and 900 nm, which allows the visualization of blood vessels for the venepuncture procedure with the aim of reducing the trauma of venous access to patients of all ages. The possibility that the device is used in the location of venous ulcers as an alternative to veno grams obtained by X-rays is also explored. (Author)

  19. Automatic blood detection in capsule endoscopy video

    Czech Academy of Sciences Publication Activity Database

    Novozámský, Adam; Flusser, Jan; Tachecí, I.; Sulík, L.; Bureš, J.; Krejcar, O.

    2016-01-01

    Roč. 21, č. 12 (2016), s. 1-8, č. článku 126007. ISSN 1083-3668 R&D Projects: GA ČR GA15-16928S Institutional support: RVO:67985556 Keywords : Automatic blood detection * capsule endoscopy video Subject RIV: JD - Computer Applications, Robotics Impact factor: 2.530, year: 2016 http://library.utia.cas.cz/separaty/2016/ZOI/flusser-0466936.pdf

  20. Effects of a protein glycocalyx in the hemodynamics of small blood vessels

    Science.gov (United States)

    Dimakopoulos, Yiannis; Delidakis, George; Tsamopoulos, John

    2015-11-01

    Glycocalyx is a protein layer of approximate thickness 0.5 μm that lines vessel walls. We study the effects this layer has on the blood flow inside arterioles and venules, where the relative size of the glycocalyx is significant. To properly describe phenomena that naturally occur in blood flow, such as the inhomogeneous distribution of red blood cells and their aggregation, we use an improved viscoelastic constitutive model. The glycocalyx layer is modeled as fixed porous media. Cells cannot penetrate inside it, since its hydraulic permeability is very low, and the flow inside this layer is described by the equations for a viscous fluid with an extra Brinkman term to account for the effects the porous medium has on the flow. The closed set of equations is solved using the Finite Element method, assuming steady-state with dependence only in the r-direction. Our results are favorably compared with the in vivo velocity profiles in venules of mice produced by Damiano et al. (2004) and the formation of cell-free layer near glycocalyx. Flow inside the glycocalyx layer is found to be severely attenuated due to the low hydraulic permeability, which can have interesting implications in the transport of various substances form the blood to the tissues or in the use of shear stresses as signals for the endothelial surface cells. Finally, we simulate the transient blood flow under pulsatile conditions.

  1. Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels

    International Nuclear Information System (INIS)

    Sivaramakrishnan, Mathangi; Maslov, Konstantin; Zhang, Hao F; Stoica, George; Wang, Lihong V

    2007-01-01

    We investigate the feasibility of obtaining accurate quantitative information, such as local blood oxygenation level (sO 2 ), with a spatial resolution of about 50 μm from spectral photoacoustic (PA) measurements. The optical wavelength dependence of the peak values of the PA signals is utilized to obtain the local blood oxygenation level. In our in vitro experimental models, the PA signal amplitude is found to be linearly proportional to the blood optical absorption coefficient when using ultrasonic transducers with central frequencies high enough such that the ultrasonic wavelengths are shorter than the light penetration depth into the blood vessels. For an optical wavelength in the 578-596 nm region, with a transducer central frequency that is above 25 MHz, the sensitivity and accuracy of sO 2 inversion is shown to be better than 4%. The effect of the transducer focal position on the accuracy of quantifying blood oxygenation is found to be negligible. In vivo oxygenation measurements of rat skin microvasculature yield results consistent with those from in vitro studies, although factors specific to in vivo measurements, such as the spectral dependence of tissue optical attenuation, dramatically affect the accuracy of sO 2 quantification in vivo

  2. A numerical analysis on the curved bileaflet Mechanical Heart Valve (MHV) : leaflet motion and blood flow in an elastic blood vessel

    International Nuclear Information System (INIS)

    Bang, Jin Seok; Kim, Chang Nyung; Choi, Choeng Ryul

    2005-01-01

    In blood flow passing through the Mechanical Heart Valve (MHV) and elastic blood vessel, hemolysis and platelet activation causing thrombus formation can be seen owing to the shear stress in the blood. Also, fracture and deformation of leaflets can be observed depending on the shape and material properties of the leaflets which is opened and closed in a cycle. Hence, comprehensive study is needed on the hemodynamics which is associated with the motion of leaflet and elastic blood vessel in terms of fluid-structure interaction. In this paper, a numerical analysis has been performed for a three-dimensional pulsatile blood flow associated with the elastic blood vessel and curved bileaflet for multiple cycles in light of fluid-structure interaction. From this analysis fluttering phenomenon and rebound of the leaflet have been observed and recirculation and regurgitation have been found in the flow fields of the blood. Also, the pressure distribution and the radial displacement of the elastic blood vessel have been obtained. The motion of the leaflet and flow fields of the blood have shown similar tendency compared with the previous experiments carried out in other studies. The present study can contribute to the design methodology for the curved bileaflet mechanical heart valve. Furthermore, the proposed fluid-structure interaction method will be effectively used in various fields where the interaction between fluid flow and structure are involved

  3. Analysis of trends and prospects regarding stents for human blood vessels.

    Science.gov (United States)

    Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo

    2018-01-01

    The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used

  4. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... (ICC) and limits of agreement. RESULTS: Fifteen minutes of hyperoxia was accompanied by mean reductions in arterial and venous perfusion velocities of 14% and 16%, respectively (p = 0.0080; p = 0.0019), constriction of major arteries and veins by 5.5% and 8.2%, respectively (p ...). For perfusion velocities, short-term ICCs were 0.79-0.82 and long-term ICCs were 0.06-0.11. Intersession increases in blood glucose were associated with reductions in perfusion velocities (arterial p = 0.0067; venous p = 0.018). CONCLUSION: Oxygen reactivity testing supported that motion-contrast velocimetry...

  5. Blood Pressure Control in Aging Predicts Cerebral Atrophy Related to Small-Vessel White Matter Lesions

    Directory of Open Access Journals (Sweden)

    Kyle C. Kern

    2017-05-01

    Full Text Available Cerebral small-vessel damage manifests as white matter hyperintensities and cerebral atrophy on brain MRI and is associated with aging, cognitive decline and dementia. We sought to examine the interrelationship of these imaging biomarkers and the influence of hypertension in older individuals. We used a multivariate spatial covariance neuroimaging technique to localize the effects of white matter lesion load on regional gray matter volume and assessed the role of blood pressure control, age and education on this relationship. Using a case-control design matching for age, gender, and educational attainment we selected 64 participants with normal blood pressure, controlled hypertension or uncontrolled hypertension from the Northern Manhattan Study cohort. We applied gray matter voxel-based morphometry with the scaled subprofile model to (1 identify regional covariance patterns of gray matter volume differences associated with white matter lesion load, (2 compare this relationship across blood pressure groups, and (3 relate it to cognitive performance. In this group of participants aged 60–86 years, we identified a pattern of reduced gray matter volume associated with white matter lesion load in bilateral temporal-parietal regions with relative preservation of volume in the basal forebrain, thalami and cingulate cortex. This pattern was expressed most in the uncontrolled hypertension group and least in the normotensives, but was also more evident in older and more educated individuals. Expression of this pattern was associated with worse performance in executive function and memory. In summary, white matter lesions from small-vessel disease are associated with a regional pattern of gray matter atrophy that is mitigated by blood pressure control, exacerbated by aging, and associated with cognitive performance.

  6. Anatomy-based automatic detection and segmentation of major vessels in thoracic CTA images

    International Nuclear Information System (INIS)

    Zou Xiaotao; Liang Jianming; Wolf, M.; Salganicoff, M.; Krishnan, A.; Nadich, D.P.

    2007-01-01

    Existing approaches for automated computerized detection of pulmonary embolism (PE) using computed tomography angiography (CTA) usually focus on segmental and sub-segmental emboli. The goal of our current research is to extend our existing approach to automated detection of central PE. In order to detect central emboli, the major vessels must be first identified and segmented automatically. This submission presents an anatomy-based method for automatic computerized detection and segmentation of aortas and main pulmonary arteries in CTA images. (orig.)

  7. Method for Separation of Blood Vessels on the Three-Color Images of Biological Tissues

    Science.gov (United States)

    Lisenko, S. A.

    2017-07-01

    A new technology was developed to improve the visibility of blood vessels on images of tissues of hollow human organs(the alimentary tract and respiratory system) based on the relation between the color components of the image, the scattering properties of the tissue, and its hemoglobin content. A statistical operator was presented to convert the three-color image of the tissue into a parametric map objectively characterizing the concentration of hemoglobin in the tissue regardless of the illumination and shooting conditions. An algorithm for obtaining conversion parameters for image systems with known spectral characteristics was presented. An image of a multilayer multiple-scattering medium modeling bronchial tissue was synthesized and was used to evaluate the efficiency of the proposed conversion system. It was shown that the conversion made it possible to increase the contrast of the blood vessels by almost two orders of magnitude, to significantly improve the clarity of the display of their borders, and to eliminate almost completely the influence of background and nonuniform illumination of the medium in comparison with the original image.

  8. Imaging transient blood vessel fusion events in zebrafish by correlative volume electron microscopy.

    Directory of Open Access Journals (Sweden)

    Hannah E J Armer

    Full Text Available The study of biological processes has become increasingly reliant on obtaining high-resolution spatial and temporal data through imaging techniques. As researchers demand molecular resolution of cellular events in the context of whole organisms, correlation of non-invasive live-organism imaging with electron microscopy in complex three-dimensional samples becomes critical. The developing blood vessels of vertebrates form a highly complex network which cannot be imaged at high resolution using traditional methods. Here we show that the point of fusion between growing blood vessels of transgenic zebrafish, identified in live confocal microscopy, can subsequently be traced through the structure of the organism using Focused Ion Beam/Scanning Electron Microscopy (FIB/SEM and Serial Block Face/Scanning Electron Microscopy (SBF/SEM. The resulting data give unprecedented microanatomical detail of the zebrafish and, for the first time, allow visualization of the ultrastructure of a time-limited biological event within the context of a whole organism.

  9. Segmentation of retinal blood vessels using normalized Gabor filters and automatic thresholding

    Directory of Open Access Journals (Sweden)

    Mandlenkosi Victor Gwetu

    2014-12-01

    Full Text Available Although computerized retinal image blood vessel segmentation has been extensively researched, there is still room for improvement in the quality of the segmented images. Since retinal image analysis is still widely used in the diagnosis of diabetic retinopathy, efficient and accurate image characterization techniques are required. Previous work has mainly focused on improving segmentation accuracy rates with little regard to the false positives that are produced by illumination variation. This research work presents a hybrid approach towards the segmentation of retinal blood vessels. New approaches towards the reduction of background illumination variation are proposed using normalized Gabor filtering. These are the base-offset encoding and a modified version of an existing zero-integral kernel technique. The valley emphasis automatic thresholding scheme is used to segment the Gabor response images. Experiments are conducted on the DRIVE and STARE retinal image data sets. Accuracy rates of up to 94% are achieved through the zero-integral and base offset methods. This is comparable with results from literature, where the same data sets are segmented using other classification techniques. The median-offset method is found to most effectively reduce background illumination variation.

  10. [Flap repair for vascular prosthesis exposure after artificial blood vessel bypass surgery for critical limb ischemia].

    Science.gov (United States)

    Wu, Wei-wei; Wu, Hao; Zeng, Ang; Bai, Ming; Zeng, Rong; Chen, Yu; Liu, Chang-wei

    2013-08-01

    To investigate the effectiveness of flap repair for vascular prosthesis exposure after the artificial blood vessel bypass surgery for critical limb ischemia. From August 2007 to December 2011, bypass surgery with vascular prosthetic grafts were performed in 192 patients with critical limb ischemia.Five patients among them (2.6%) suffered from vascular prosthesis exposure 6 to 13 days after the previous surgery, including 4 males and 1 female, with a median age of 68 years(arranged from 52 to 81 years). The surgical managements included surgical debridement and local flap or transferred muscle-cutaneous flap repair to preserve the prosthetic vascular grafts. Three patients underwent Z-plasty with local flap repair, while 2 patients underwent transferred rectus abdominis or rectus femoris muscle flap repair of the wounds. After the surgery, prosthetic vascular graft was successfully preserved in 4 of the 5 cases with first intention healing. At a median follow-up of 38 months (arranged from 5 to 57 months), all the 4 limbs were salvaged with patent of the prosthetic grafts.One flap failed to heal and the prosthetic graft had to be removed due to infection and hemorrhage. An above-knee-amputation was performed due to severe limb ischemia. The vascular prosthesis exposure is often a disaster after artificial blood vessel bypass surgery for critical limb ischemia.Local flap or transferred muscle-cutaneous flap repair is an effective surgical management to salvage the exposed graft and the affected limb.

  11. Defining an adequate sample of earlywood vessels for retrospective injury detection in diffuse-porous species.

    Directory of Open Access Journals (Sweden)

    Estelle Arbellay

    Full Text Available Vessels of broad-leaved trees have been analyzed to study how trees deal with various environmental factors. Cambial injury, in particular, has been reported to induce the formation of narrower conduits. Yet, little or no effort has been devoted to the elaboration of vessel sampling strategies for retrospective injury detection based on vessel lumen size reduction. To fill this methodological gap, four wounded individuals each of grey alder (Alnus incana (L. Moench and downy birch (Betula pubescens Ehrh. were harvested in an avalanche path. Earlywood vessel lumina were measured and compared for each tree between the injury ring built during the growing season following wounding and the control ring laid down the previous year. Measurements were performed along a 10 mm wide radial strip, located directly next to the injury. Specifically, this study aimed at (i investigating the intra-annual duration and local extension of vessel narrowing close to the wound margin and (ii identifying an adequate sample of earlywood vessels (number and intra-ring location of cells attesting to cambial injury. Based on the results of this study, we recommend analyzing at least 30 vessels in each ring. Within the 10 mm wide segment of the injury ring, wound-induced reduction in vessel lumen size did not fade with increasing radial and tangential distances, but we nevertheless advise favoring early earlywood vessels located closest to the injury. These findings, derived from two species widespread across subarctic, mountainous, and temperate regions, will assist retrospective injury detection in Alnus, Betula, and other diffuse-porous species as well as future related research on hydraulic implications after wounding.

  12. Effect of collagen and elastin content on the burst pressure of human blood vessel seals formed with a bipolar tissue sealing system.

    Science.gov (United States)

    Latimer, Cassandra A; Nelson, Meghan; Moore, Camille M; Martin, Kimberly E

    2014-01-01

    Bipolar devices are routinely used to seal blood vessels instead of sutures and clips. Recent work examining the impact of vascular proteins on bipolar seal performance found that collagen and elastin (CE) content within porcine arteries was a significant predictor of a vessel's burst pressure (VBPr). This study examined seal performance across a range of human blood vessels to investigate whether a similar relationship existed. In addition, we compared VBPr and CE content between porcine and human blood vessels. Our primary hypothesis is that higher collagen-to-elastin ratio will predict higher VBPr in human vasculature. In six cadavers, 185 blood vessels from nine anatomic locations were sealed using a bipolar electrosurgical system. A linear mixed model framework was used to evaluate the impact of vessel diameter and CE content on VBPr. The effect of CE ratio on VBPr is modified by vessel size, with CE ratio having larger influence on VBPr in smaller diameter vessels. Seal burst pressure of vessels 2-5 mm in diameter was significantly associated with their CE content. Comparison of average VBPr between species revealed porcine carotid and iliac arteries (440-670 mmHg) to be the best vessel types for predicting the seal strength of most human blood vessels (420-570 mmHg) examined. CE content significantly modified the seal strength of small to medium sized blood vessels but had limited impact on vessels >5 mm. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Anatomical relationships of the pia mater to cerebral blood vessels in man.

    Science.gov (United States)

    Hutchings, M; Weller, R O

    1986-09-01

    Using scanning and transmission electron microscopy and light microscopy, the authors studied the human pia mater and its relationship to the entry of blood vessels into the normal cerebral cortex. The purpose of this investigation was to examine the long-established concept that the subarachnoid space communicates directly with the perivascular spaces of the cerebral cortex. Brains obtained post mortem from subjects with recent subarachnoid hemorrhage (SAH) and purulent leptomeningitis were studied by light microscopy to determine the permeability of the pia mater to red blood cells and inflammatory cells. Scanning electron microscopy showed that the normal pia mater is a flat sheet of cells that is reflected from the surface of the brain to form the outer coating of the meningeal vessels in the subarachnoid space. Transmission electron microscopy confirmed that the cells of the pia mater are joined by junctional complexes and form a continuous sheet that separates the subarachnoid space on one side from the subpial and perivascular spaces on the other. Thus, neither the pia mater nor the subarachnoid space extends into the brain beside blood vessels as they enter the cerebral cortex. The perivascular spaces were, in fact, found to be confluent with the subpial space and not with the subarachnoid space. In cases of recent SAH, red blood cells did not enter the perivascular spaces from the subarachnoid space; neither did India ink injected post mortem into the subarachnoid space pass into the perivascular spaces. The results of these crude tracer studies suggest that the pia mater is an effective barrier to the passage of particulate matter. Histological examination of brains of patients who had died with purulent leptomeningitis showed that inflammatory cells were present in the cortical perivascular spaces and in the contiguous subpial spaces. The presence of a large number of inflammatory cells in the subarachnoid space suggests that inflammatory cells readily

  14. Fast retinal vessel detection and measurement using wavelets and edge location refinement.

    Directory of Open Access Journals (Sweden)

    Peter Bankhead

    Full Text Available The relationship between changes in retinal vessel morphology and the onset and progression of diseases such as diabetes, hypertension and retinopathy of prematurity (ROP has been the subject of several large scale clinical studies. However, the difficulty of quantifying changes in retinal vessels in a sufficiently fast, accurate and repeatable manner has restricted the application of the insights gleaned from these studies to clinical practice. This paper presents a novel algorithm for the efficient detection and measurement of retinal vessels, which is general enough that it can be applied to both low and high resolution fundus photographs and fluorescein angiograms upon the adjustment of only a few intuitive parameters. Firstly, we describe the simple vessel segmentation strategy, formulated in the language of wavelets, that is used for fast vessel detection. When validated using a publicly available database of retinal images, this segmentation achieves a true positive rate of 70.27%, false positive rate of 2.83%, and accuracy score of 0.9371. Vessel edges are then more precisely localised using image profiles computed perpendicularly across a spline fit of each detected vessel centreline, so that both local and global changes in vessel diameter can be readily quantified. Using a second image database, we show that the diameters output by our algorithm display good agreement with the manual measurements made by three independent observers. We conclude that the improved speed and generality offered by our algorithm are achieved without sacrificing accuracy. The algorithm is implemented in MATLAB along with a graphical user interface, and we have made the source code freely available.

  15. Ovarian blood vessel occlusion as a surgical sterilization method in rats.

    Science.gov (United States)

    Murakami, Eduardo; Sartori de Camargo, Laíza; Freitas Cardoso, Karym Christine de; Miguel, Marina Pacheco; Tavares, Denise Cláudia; Santos Honsho, Cristiane dos; Ferreira de Souza, Fabiana

    2014-04-01

    To evaluate the female sterilization by occlusion of the ovarian blood flow, using the rat as experimental model. Fifty-five females rats were divided into four groups: I (n=10), bilateral ovariectomy, euthanized at 60 or 90 days; II (n=5), opening the abdominal cavity, euthanized at 90 days; III (n=20), bilateral occlusion of the ovarian blood supply using titanium clips, euthanized at 60 or 90 days; and IV (n=20), bilateral occlusion of the ovarian blood supply using nylon thread, euthanized at 60 or 90 days. The estrous cycle was monitored by vaginal cytology. After euthanasia, the reproductive tissues were evaluated histologically. Ovarian atresia was identified macroscopically at 60 days after surgery in the rats in groups III and IV; however, most of the rats in group III maintained cyclicity. Histology of the tissues from group IV revealed that the ovarian tissue was replaced by dense fibrous connective tissue that was slightly vascularized and that intact follicles were absent by 90 days. Ovarian blood vessels occluded caused ischemia, leading to progressive tissue necrosis, and bilateral occlusion using a nylon ligature is a viable method for surgical sterilization.

  16. Comparison of adenoid cystic carcinomas arising from the parotid gland vs. the submandibular gland: focus on systemic metastasis and tumor-associated blood vessels.

    Science.gov (United States)

    Shin, Da-Yong; Jang, Kyu-Sun; Kim, Bo Young; Choi, Ji Eun; Yoon, Heejei; Ko, Young-Hyeh; Jeong, Han-Sin

    2014-07-01

    Although several studies reported that distant metastasis occurs more frequently in the tumors of submandibular gland (SMG) than parotid gland (PG), why SMG tumors preferentially metastasize to distant organs is not fully understood. We aimed to identify the differential tumor microenvironment for distant metastasis and possible underlying mechanisms. We retrieved 27 cases of 1-4-cm-sized adenoid cystic carcinomas (ACCs) arising from the PG (n = 12) and SMG (n = 15). c-KIT, VEGF-R2, and CD31 staining were quantified by image-based analysis to define the positive expression or tumor-associated vessel areas in two representative sections per case. In addition, angiogenesis-related genomic expression profiling was carried out to explore the underlying mechanism, which was confirmed by RT-PCR and immunohistochemistry. Earlier systemic dissemination within 2 years was detected exclusively in SMG ACCs (5/15). The area of tumor-associated blood vessels was larger in SMG ACCs than PG ACCs, and ACCs showing distant metastasis had greater blood vessel area than those without metastasis. Interestingly, normal SMG had more blood vessels per area than PG. Among angiogenesis-related signals, the level of IL-6 was significantly lower in SMG ACCs than PG ACCs. Moreover, IL-6 expression decreased significantly in SMG ACCs compared with that in normal SMG, whereas it was up-regulated in PG ACCs. ACCs in the SMG microenvironment have more abundant tumor-associated blood vessels than PG ACCs, which may explain the higher risk of distant metastasis from SMG tumors. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Regulator of G-protein signaling 5 controls blood pressure homeostasis and vessel wall remodeling.

    Science.gov (United States)

    Holobotovskyy, Vasyl; Manzur, Mitali; Tare, Marianne; Burchell, Jennifer; Bolitho, Erin; Viola, Helena; Hool, Livia C; Arnolda, Leonard F; McKitrick, Douglas J; Ganss, Ruth

    2013-03-01

    Regulator of G-protein signaling 5 (RGS5) modulates G-protein-coupled receptor signaling and is prominently expressed in arterial smooth muscle cells. Our group first reported that RGS5 is important in vascular remodeling during tumor angiogenesis. We hypothesized that RGS5 may play an important role in vessel wall remodeling and blood pressure regulation. To demonstrate that RGS5 has a unique and nonredundant role in the pathogenesis of hypertension and to identify crucial RGS5-regulated signaling pathways. We observed that arterial RGS5 expression is downregulated with chronically elevated blood pressure after angiotensin II infusion. Using a knockout mouse model, radiotelemetry, and pharmacological inhibition, we subsequently showed that loss of RGS5 results in profound hypertension. RGS5 signaling is linked to the renin-angiotensin system and directly controls vascular resistance, vessel contractility, and remodeling. RGS5 deficiency aggravates pathophysiological features of hypertension, such as medial hypertrophy and fibrosis. Moreover, we demonstrate that protein kinase C, mitogen-activated protein kinase/extracellular signal-regulated kinase, and Rho kinase signaling pathways are major effectors of RGS5-mediated hypertension. Loss of RGS5 results in hypertension. Loss of RGS5 signaling also correlates with hyper-responsiveness to vasoconstrictors and vascular stiffening. This establishes a significant, distinct, and causal role of RGS5 in vascular homeostasis. RGS5 modulates signaling through the angiotensin II receptor 1 and major Gαq-coupled downstream pathways, including Rho kinase. So far, activation of RhoA/Rho kinase has not been associated with RGS molecules. Thus, RGS5 is a crucial regulator of blood pressure homeostasis with significant clinical implications for vascular pathologies, such as hypertension.

  18. Bioprinting of artificial blood vessels: current approaches towards a demanding goal.

    Science.gov (United States)

    Hoch, Eva; Tovar, Günter E M; Borchers, Kirsten

    2014-11-01

    Free-form fabrication techniques, often referred to as '3D printing', are currently tested with regard to the processing of biological and biocompatible materials in general and for fabrication of vessel-like structures in particular. Such computer-controlled methods assemble 3D objects by layer-wise deposition or layer-wise cross-linking of materials. They use, for example, nozzle-based deposition of hydrogels and cells, drop-on-demand inkjet-printing of cell suspensions with subsequent cross-linking, layer-by-layer cross-linking of synthetic or biological polymers by selective irradiation with light and even laser-induced deposition of single cells. The need of vessel-like structures has become increasingly crucial for the supply of encapsulated cells for 3D tissue engineering, or even with regard to future application such as vascular grafts. The anticipated potential of providing tubes with tailored branching geometries made of biocompatible or biological materials pushes future visions of patient-specific vascularized tissue substitutions, tissue-engineered blood vessels and bio-based vascular grafts. We review here the early attempts of bringing together innovative free-form manufacturing processes with bio-based and biodegradable materials. The presented studies provide many important proofs of concepts such as the possibility to integrate viable cells into computer-controlled processes and the feasibility of supplying cells in a hydrogel matrix by generation of a network of perfused channels. Several impressive results in the generation of complex shapes and high-aspect-ratio tubular structures demonstrate the potential of additive assembly methods. Yet, it also becomes obvious that there remain major challenges to simultaneously match all material requirements in terms of biological functions (cell function supporting properties), physicochemical functions (mechanical properties of the printed material) and process-related (viscosity, cross

  19. Role of Outgassing of ITER Vacuum Vessel In-Wall Shielding Materials in Leak Detection of ITER Vacuum Vessel

    Science.gov (United States)

    Maheshwari, A.; Pathak, H. A.; Mehta, B. K.; Phull, G. S.; Laad, R.; Shaikh, M. S.; George, S.; Joshi, K.; Khan, Z.

    2017-04-01

    ITER Vacuum Vessel is a torus-shaped, double wall structure. The space between the double walls of the VV is filled with In-Wall Shielding Blocks (IWS) and Water. The main purpose of IWS is to provide neutron shielding during ITER plasma operation and to reduce ripple of Toroidal Magnetic Field (TF). Although In-Wall Shield Blocks (IWS) will be submerged in water in between the walls of the ITER Vacuum Vessel (VV), Outgassing Rate (OGR) of IWS materials plays a significant role in leak detection of Vacuum Vessel of ITER. Thermal Outgassing Rate of a material critically depends on the Surface Roughness of material. During leak detection process using RGA equipped Leak detector and tracer gas Helium, there will be a spill over of mass 3 and mass 2 to mass 4 which creates a background reading. Helium background will have contribution of Hydrogen too. So it is necessary to ensure the low OGR of Hydrogen. To achieve an effective leak test it is required to obtain a background below 1 × 10-8 mbar 1 s-1 and hence the maximum Outgassing rate of IWS Materials should comply with the maximum Outgassing rate required for hydrogen i.e. 1 x 10-10 mbar 1 s-1 cm-2 at room temperature. As IWS Materials are special materials developed for ITER project, it is necessary to ensure the compliance of Outgassing rate with the requirement. There is a possibility of diffusing the gasses in material at the time of production. So, to validate the production process of materials as well as manufacturing of final product from this material, three coupons of each IWS material have been manufactured with the same technique which is being used in manufacturing of IWS blocks. Manufacturing records of these coupons have been approved by ITER-IO (International Organization). Outgassing rates of these coupons have been measured at room temperature and found in acceptable limit to obtain the required Helium Background. On the basis of these measurements, test reports have been generated and got

  20. Detection of solvent losses (entrainment) in gas streams of process vessels using radioisotope tracing techniques

    International Nuclear Information System (INIS)

    Wan Zakaria Wan Muhamad Tahir; Juhari Mohd Yusof

    2002-01-01

    Liquid droplets (MDEA aqueous solution) entrained in the gas streams can cause severe problems on chemical plants. On-line detection of liquid entrainment (carry over) into gas streams from process vessel is investigated using radioisotope iodine ( 131 I). In order to obtain information on whether there is any carry-over of MDEA in the vapour space leaving from the process system, a number of test and calibration injections involving the released of certain amount of tracer activity (mCi) at the inlet and overhead lines of the process vessels were made using a special injection device. MDEA solvent- tagged tracer in the overhead line of the designated process vessels was monitored using radiation scintillation detectors mounted externally at specified locations of the vessels. Output pulses (response curves) with respect to time of measurements from all detectors were plotted and analysed for the finger prints of solvent losses leaving the vessels. From this study, no distinguishable peaks were detected at the outlet vessels of the overhead lines. Thus, no significant MDEA solvent losses in the form of vapour being discovered along the gas streams due to the process taking place in the system. (Author)

  1. Patency of heart blood vessels under photosensitization reaction shortly after intravenous injection of talaporfin sodium in canine model

    Science.gov (United States)

    Hamada, Risa; Matsuzaki, Ryota; Ogawa, Emiyu; Arai, Tsunenori

    2016-03-01

    In order to investigate patency of heart blood vessels by photosensitization reaction shortly after intravenous injection of talaporfin sodium, we performed in vitro endothelial cell lethality study and in vivo study of heart blood vessel patency in canine one week after photosensitization reaction. Cell lethality of human umbilical vein endothelial cells under different albumin concentrations corresponding with blood and interstice concentrations were employed and their lethality 2 hours after the reaction was measured by WST assay in vitro. Almost all cells survived by 40 J/cm2 photosensitization reaction with blood albumin concentration. Laser diffuser made of plastic optical fiber with 70 mm in length was used in vivo. Red diode laser of 664nm wavelength was emitted from this diffuser with 17.1-42.9 mW/cm in 10 minutes. We estimated the fluence rate distribution by a ray-trace simulator using pre-measured optical coefficients of myocardium tissue, μa 0.12 mm-1 and μs' 0.36 mm-1. Almost all blood vessels were patent in every irradiation conditions in canine heart. Coronary artery and vein up to 1 mm diameter were patent in typical myocardium sample with 25.7 mW/cm. We estimated fluence rate distribution of this sample and found that blood vessels were patent even fluence rate over 40 J/cm2. This in vivo study could be explained by the result of in vitro study. We suggest that this blood vessel patency after our particular photosensitization reaction might be because of few photosensitizer uptake in the blood endothelial cells and/or reduced oxidation damage by thick albumin concentration in blood.

  2. Chronic hydrocephalus-induced hypoxia: increased expression of VEGFR-2+ and blood vessel density in hippocampus.

    Science.gov (United States)

    Dombrowski, S M; Deshpande, A; Dingwall, C; Leichliter, A; Leibson, Z; Luciano, M G

    2008-03-18

    Chronic hydrocephalus (CH) is a neurological disease characterized by increased cerebrospinal fluid volume and pressure that is often associated with impaired cognitive function. By and large, CH is a complex and heterogeneous cerebrospinal fluid (CSF) disorder where the exact site of brain insult is uncertain. Several mechanisms including neural compression, fiber stretch, and local or global hypoxia have been implicated in the underlying pathophysiology of CH. Specifically, the hippocampus, which plays a significant role in memory processing and is in direct contact with expanding CSF ventricles, may be involved. Using our model of chronic hydrocephalus, we quantified the density of vascular endothelial growth factor receptor 2 (VEGFR-2(+)) neurons, glial, endothelial cells, and blood vessels in hippocampal regions CA1, CA2-3, dentate gyrus and hilus using immunohistochemical and stereological methods. Density and %VEGFR-2(+) cell populations were estimated for CH animals (2-3 weeks vs. 12-16 weeks) and surgical controls (SC). Overall, we found approximately six- to eightfold increase in the cellular density of VEGFR-2(+) and more than double blood vessel density (BVd) in the hippocampus of CH compared with SC. There were no significant regional differences in VEGFR-2(+) cellular and BVd expression in the CH group. VEGFR-2(+) and BVds were significantly related to changes in CSF volume (Pblood vessel expression was related to focal compression alone or in combination with global ischemia/hypoxia conditions as previously described. These findings suggest that VEGFR-2 may play an adaptive role in angiogenesis after CH

  3. Distinct mechanisms of relaxation to bioactive components from chamomile species in porcine isolated blood vessels

    International Nuclear Information System (INIS)

    Roberts, R.E.; Allen, S.; Chang, A.P.Y.; Henderson, H.; Hobson, G.C.; Karania, B.; Morgan, K.N.; Pek, A.S.Y.; Raghvani, K.; Shee, C.Y.; Shikotra, J.; Street, E.; Abbas, Z.; Ellis, K.; Heer, J.K.; Alexander, S.P.H.

    2013-01-01

    German chamomile (Matricaria recutita L.), a widely-used herbal medicine, has been reported to have a wide range of biological effects, including smooth muscle relaxation. The aim of this study was to compare the effects of representative compounds from chamomile (apigenin, luteolin, (−)-α-bisabolol, farnesene, umbelliferone; 3–30 μM) on vascular tone using porcine coronary and splenic arteries mounted for isometric tension recording in isolated tissue baths and precontracted with the thromboxane-mimetic U46619. Apigenin, luteolin, and (−)-α-bisabolol produced slow, concentration-dependent relaxations in both the coronary and splenic arteries that were not blocked by inhibition of nitric oxide synthase or potassium channels. Removal of extracellular calcium inhibited the relaxations to all three compounds, and these compounds also inhibited calcium re-addition-evoked contractions, indicating that the relaxation response may be mediated through inhibition of calcium influx. Apigenin and luteolin, but not (−)-α-bisabolol, enhanced the relaxation to the nitric oxide donor sodium nitroprusside, indicating that apigenin and luteolin may act to regulate cyclic GMP levels. Umbelliferone produced a rapid, transient relaxation in the splenic artery, but not the coronary artery, that was inhibited by L-NAME and removal of the endothelium, suggesting an influence on nitric oxide production. Farnesene, at concentrations up to 30 μM, was without effect in either blood vessel. In conclusion, hydroxylated compounds (apigenin, luteolin and (−)-α-bisabolol) found in chamomile all caused a slow relaxation of isolated blood vessels through an effect on calcium influx. Umbelliferone, on the other hand, produced a rapid, transient relaxation dependent upon release of nitric oxide from the endothelium. - Highlights: • Apigenin, luteolin, and (-)-α-bisabolol are present in chamomile. • They produced slow, concentration-dependent relaxations in arteries. • These

  4. Distinct mechanisms of relaxation to bioactive components from chamomile species in porcine isolated blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, R.E., E-mail: Richard.roberts@nottingham.ac.uk; Allen, S.; Chang, A.P.Y.; Henderson, H.; Hobson, G.C.; Karania, B.; Morgan, K.N.; Pek, A.S.Y.; Raghvani, K.; Shee, C.Y.; Shikotra, J.; Street, E.; Abbas, Z.; Ellis, K.; Heer, J.K.; Alexander, S.P.H., E-mail: steve.alexander@nottingham.ac.uk

    2013-11-01

    German chamomile (Matricaria recutita L.), a widely-used herbal medicine, has been reported to have a wide range of biological effects, including smooth muscle relaxation. The aim of this study was to compare the effects of representative compounds from chamomile (apigenin, luteolin, (−)-α-bisabolol, farnesene, umbelliferone; 3–30 μM) on vascular tone using porcine coronary and splenic arteries mounted for isometric tension recording in isolated tissue baths and precontracted with the thromboxane-mimetic U46619. Apigenin, luteolin, and (−)-α-bisabolol produced slow, concentration-dependent relaxations in both the coronary and splenic arteries that were not blocked by inhibition of nitric oxide synthase or potassium channels. Removal of extracellular calcium inhibited the relaxations to all three compounds, and these compounds also inhibited calcium re-addition-evoked contractions, indicating that the relaxation response may be mediated through inhibition of calcium influx. Apigenin and luteolin, but not (−)-α-bisabolol, enhanced the relaxation to the nitric oxide donor sodium nitroprusside, indicating that apigenin and luteolin may act to regulate cyclic GMP levels. Umbelliferone produced a rapid, transient relaxation in the splenic artery, but not the coronary artery, that was inhibited by L-NAME and removal of the endothelium, suggesting an influence on nitric oxide production. Farnesene, at concentrations up to 30 μM, was without effect in either blood vessel. In conclusion, hydroxylated compounds (apigenin, luteolin and (−)-α-bisabolol) found in chamomile all caused a slow relaxation of isolated blood vessels through an effect on calcium influx. Umbelliferone, on the other hand, produced a rapid, transient relaxation dependent upon release of nitric oxide from the endothelium. - Highlights: • Apigenin, luteolin, and (-)-α-bisabolol are present in chamomile. • They produced slow, concentration-dependent relaxations in arteries. • These

  5. Blood meal and blood products detection using Synchronous fluorescence spectroscopy

    OpenAIRE

    Lecrenier, Marie-Caroline; Abbas, Ouissam; Taira, Aurélien; Arnould, Quentin; Baeten, Vincent

    2016-01-01

    In Europe, ruminant processed animal proteins (PAPs) and blood products are not allowed to be used in feed for farmed animal. In contrast, blood meal and blood products of porcine origin are both authorised in aqua feed, whereas only porcine blood products are allowed to be used in feed intended for other non-ruminants. Besides official methods (light microscopy and PCR), complementary methods are developed in order to refine the by-products identification. By-products derived from blood ...

  6. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing [Huadong Hospital Fudan University, Department of Radiology, Shanghai (China); Zheng, Xiangpeng [Huadong Hospital Fudan University, Department of Radiation Oncology, Shanghai (China); Chen, Yan [Huadong Hospital Fudan University, Department of Pathology, Shanghai (China); Lv, Fangzhen [Huadong Hospital Fudan University, Department of Thoracic Surgery, Shanghai (China)

    2013-12-15

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  7. The Effect of Silver Nanofibers on the Deformation Properties of Blood Vessels: Towards the Development of New Nanotechnologies to Prevent Rupture of Aneurysms

    Directory of Open Access Journals (Sweden)

    Miguel Gonzalez

    2014-01-01

    Full Text Available An aneurysm is the result of a widening or ballooning of a portion of a blood vessel. The rupture of an aneurysm occurs when the mechanical stress acting on the inner wall exceeds the failure strength of the blood vessel. We propose an innovative approach to prevent the rupture of an aneurysm based on the use of nanotechnology to improve the strength of the blood vessel. We present results on the effect of silver nanofibers on the resistance toward deformation of blood vessels. The silver nanofibers are grown on the surface of the blood vessels. The nanofibers are 120±30 nm in diameter and 2.7±0.8 μm in length. The deformation per applied force of blood vessels was found to decrease from 0.15 m/N in control blood vessels to 0.003 m/N in blood vessels treated with the nanofibers. This represents an increase in the resistance towards deformation of a factor of 50. The increase in the resistance towards deformation is clinically significant since blood pressure increases by factors slightly larger than one in the human body. Treatment of blood vessels with silver nanofibers is a potential translational clinical tool for preventing rupture of aneurysms in a clinical setting.

  8. Role of outgassing of ITER vacuum vessel in-wall shielding materials in leak detection of ITER vacuum vessel

    International Nuclear Information System (INIS)

    Maheshwari, Abha; Pathak, Haresh A.; Mehta, Bhoomi K.; Phull, Gurlovleen Singh; Laad, Rahul; Shaikh, Moin; George, Siju; Joshi, Kaushal; Khan, Ziauddin

    2015-01-01

    ITER Vacuum Vessel (VV) is a torus-shaped, double wall structure. The space between the double walls of the VV is filled with In-Wall Shielding Blocks (IWS) and Water. The main purpose of IWS is to provide neutron shielding during ITER plasma operation and to reduce ripple of Toroidal Magnetic Field (TF). Although In-Wall Shield Blocks (IWS) will be submerged in water in between the walls of the ITER Vacuum Vessel (VV), Outgassing Rate (OGR) of IWS materials plays a significant role in leak detection of Vacuum Vessel of ITER. Thermal Outgassing Rate of a material critically depends on the Surface Roughness of material. On a leak detector there will be a spillover of mass 3 and mass 2 to mass 4 which creates a background reading. Helium background will have contribution of Hydrogen too. So it is necessary to ensure the low OGR of Hydrogen. To achieve an effective leak test it is required to obtain a background below 1 x 10 -9 Pa m 3 s -1 and hence the maximum Outgassing Rate of IWS Materials should comply with the maximum Outgassing Rate required for hydrogen i.e. 1 x 10 -7 Pa m 3 s -1 m -2 at Room Temperature. As IWS Materials are special materials developed for ITER project, it is necessary to ensure the compliance of Outgassing Rate with the requirement. There is a possibility of diffusing the gasses in material at the time of production. So, to validate the production process of materials as well as manufacturing of final product from this material, three coupons of each IWS material have been manufactured with the same technique which is being used in manufacturing of IWS blocks. Manufacturing Records of these coupons have been approved by ITER-IO (International Organization). Outgassing Rates of these coupons have been measured at Room Temperature and found in acceptable limit to obtain the required Helium Background. On the basis of these measurements, test reports have been generated and got approved by IO. This paper will describe the preparation

  9. New Technique for Automatic Segmentation of Blood Vessels in CT Scan Images of Liver Based on Optimized Fuzzy C-Means Method.

    Science.gov (United States)

    Ahmadi, Katayoon; Karimi, Abbas; Fouladi Nia, Babak

    2016-01-01

    Automatic segmentation of medical CT scan images is one of the most challenging fields in digital image processing. The goal of this paper is to discuss the automatic segmentation of CT scan images to detect and separate vessels in the liver. The segmentation of liver vessels is very important in the liver surgery planning and identifying the structure of vessels and their relationship to tumors. Fuzzy C -means (FCM) method has already been proposed for segmentation of liver vessels. Due to classical optimization process, this method suffers lack of sensitivity to the initial values of class centers and segmentation of local minima. In this article, a method based on FCM in conjunction with genetic algorithms (GA) is applied for segmentation of liver's blood vessels. This method was simulated and validated using 20 CT scan images of the liver. The results showed that the accuracy, sensitivity, specificity, and CPU time of new method in comparison with FCM algorithm reaching up to 91%, 83.62, 94.11%, and 27.17 were achieved, respectively. Moreover, selection of optimal and robust parameters in the initial step led to rapid convergence of the proposed method. The outcome of this research assists medical teams in estimating disease progress and selecting proper treatments.

  10. Internal dosimetry for blood vessels radiotherapy; Dosimetria interna para terapia com radiacao em vasos sanguineos

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Laelia Pumilla Botelho [Pernambuco Univ., Recife, PE (Brazil). Dept. de Energia Nuclear] E-mail: lpbcampos@uol.com.br; Stabin, Michael Gregory [Vanderbilt Univ., Nashville, TN (United States). Dept. of Radiology and Radiological Sciences] E-mail: Michael.Stabin@mcmail.vanderbilt.edu

    2001-07-01

    Among the cardiovascular diseases, the most common is acute myocardial infarction, which occurs because of the occlusion of one or more coronary arteries. Balloon angioplasty has been a popular treatment which is less invasive than surgeries involving revascularization of the myocardium, thus promising a better quality of life for patients. Unfortunately, the rate of restenosis (re-closing of the vessel) after balloon angioplasty is high (approximately 30-50% within the first year after treatment). Known as Intravascular Brachytherapy, the technique has been used with several radiation sources, and researchers have obtained success in decreasing the rate of restenosis. In order to study the radiation dosimetry in the patient and radiological protection for this therapy, radiation dose distributions for monoenergetic electrons and photons (at nine discrete energies) were calculated for blood vessels of diameter 0.15, 0.30 and 0.45 cm with balloon and wire sources using the radiation transport code MCNP4B. Specific calculations were carried out for several radionuclides. Advantages and disadvantages of the radionuclides and source geometries are discussed and the dosimetry developed here will aid in the realization of the benefits obtained in patients. (author)

  11. Streaming flow from ultrasound contrast agents by acoustic waves in a blood vessel model.

    Science.gov (United States)

    Cho, Eunjin; Chung, Sang Kug; Rhee, Kyehan

    2015-09-01

    To elucidate the effects of streaming flow on ultrasound contrast agent (UCA)-assisted drug delivery, streaming velocity fields from sonicated UCA microbubbles were measured using particle image velocimetry (PIV) in a blood vessel model. At the beginning of ultrasound sonication, the UCA bubbles formed clusters and translated in the direction of the ultrasound field. Bubble cluster formation and translation were faster with 2.25MHz sonication, a frequency close to the resonance frequency of the UCA. Translation of bubble clusters induced streaming jet flow that impinged on the vessel wall, forming symmetric vortices. The maximum streaming velocity was about 60mm/s at 2.25MHz and decreased to 15mm/s at 1.0MHz for the same acoustic pressure amplitude. The effect of the ultrasound frequency on wall shear stress was more noticeable. Maximum wall shear stress decreased from 0.84 to 0.1Pa as the ultrasound frequency decreased from 2.25 to 1.0MHz. The maximum spatial gradient of the wall shear stress also decreased from 1.0 to 0.1Pa/mm. This study showed that streaming flow was induced by bubble cluster formation and translation and was stronger upon sonication by an acoustic wave with a frequency near the UCA resonance frequency. Therefore, the secondary radiant force, which is much stronger at the resonance frequency, should play an important role in UCA-assisted drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Simultaneous shape and deformation measurements in a blood vessel model by two wavelength interferometry

    Science.gov (United States)

    Andrés, Nieves; Pinto, Cristina; Lobera, Julia; Palero, Virginia; Arroyo, M. Pilar

    2017-06-01

    Holographic techniques have been used to measure the shape and the radial deformation of a blood vessel model and a real sheep aorta. Measurements are obtained from several holograms recorded for different object states. For each object state, two holograms with two different wavelengths are multiplexed in the same digital recording. Thus both holograms are simultaneously recorded but the information from each of them is separately obtained. The shape analysis gives a wrapped phase map whose fringes are related to a synthetic wavelength. After a filtering and unwrapping process, the 3D shape can be obtained. The shape data for each line are fitted to a circumference in order to determine the local vessel radius and center. The deformation analysis also results in a wrapped phase map, but the fringes are related to the laser wavelength used in the corresponding hologram. After the filtering and unwrapping process, a 2D map of the deformation in an out-of-plane direction is reconstructed. The radial deformation is then calculated by using the shape information.

  13. [Telescopic adhesive anastomosis of small blood vessel applied in formation of arteriovenous fistula for hemodialysis].

    Science.gov (United States)

    Shen, G; Leng, Y; Rong, G

    1997-03-01

    The formation of an arteriovenous fistual for dialysis by routine interrupted sutures anastomosing the vein and artery is difficult to perform and time-consuming. A new method, telescopic adhesive anastomosis was studied and applied in 10 hemodialysis patients, who were in need of an arteriovenous fistula. The external diameter of the vessels anastomosed was 2.40 +/- 0.20 mm (radial artery) or 2.40 +/- 0.35 mm (cephalic vein). After thorough debridement of the vascular ends, the arterial end was put in the venous lumen. In order to fix the telescopic vessels, two stitches were applied 180 degrees apart from each other and tied. Each stitch was inserted from vein (penetrating the whole wall) to artery (just through the adventitia and partial thickness of the media vasorum). The distance from the stitch to the edge of the vein was 0.5 mm, and that of the artery was approximated to the external diameter of the vessle. The medical adhesive was then applied for sealing the anastomotic adventitia. Ten seconds were given for the solidification of the adhesive. The patients were followed up for 8 months. The patency rate was 100%, and the rate of blood flow was more than 300 ml/min (measured by ultrasonography). It was shown that this method could be managed easily and quickly, and the so-formed fistula would fulfill the need of hemodialysis.

  14. Retinal blood vessel segmentation in high resolution fundus photographs using automated feature parameter estimation

    Science.gov (United States)

    Orlando, José Ignacio; Fracchia, Marcos; del Río, Valeria; del Fresno, Mariana

    2017-11-01

    Several ophthalmological and systemic diseases are manifested through pathological changes in the properties and the distribution of the retinal blood vessels. The characterization of such alterations requires the segmentation of the vasculature, which is a tedious and time-consuming task that is infeasible to be performed manually. Numerous attempts have been made to propose automated methods for segmenting the retinal vasculature from fundus photographs, although their application in real clinical scenarios is usually limited by their ability to deal with images taken at different resolutions. This is likely due to the large number of parameters that have to be properly calibrated according to each image scale. In this paper we propose to apply a novel strategy for automated feature parameter estimation, combined with a vessel segmentation method based on fully connected conditional random fields. The estimation model is learned by linear regression from structural properties of the images and known optimal configurations, that were previously obtained for low resolution data sets. Our experiments in high resolution images show that this approach is able to estimate appropriate configurations that are suitable for performing the segmentation task without requiring to re-engineer parameters. Furthermore, our combined approach reported state of the art performance on the benchmark data set HRF, as measured in terms of the F1-score and the Matthews correlation coefficient.

  15. Comparison of the number of gingival blood vessels between type 2 diabetes mellitus and chronic periodontitis patients: An immunohistological study

    Directory of Open Access Journals (Sweden)

    Gautami Subhadra Penmetsa

    2015-01-01

    Full Text Available Background: The relationship between diabetes and periodontitis has been studied for more than 50 years and is generally agreed that the periodontal disease is more prevalent in diabetic patients compared to nondiabetics. Vascular changes like increased thickness of basement membrane in small vessels has been reported in diabetic patients, but the quantity of blood vessels in gingiva of diabetic patients has not been discussed much. The aim of this study was to compare the number of blood vessels in gingiva between chronic periodontitis (CP patients, CP with diabetes (type 2, and normal healthy gingiva. Materials and Methods: The study included 75 patients, divided into three groups of 25 patients each-Group I with healthy periodontium (HP, Group II with CP, and Group III with CP with diabetes mellitus (CPDM.Gingival biopsies were obtained from the subjects undergoing crown lengthening procedure for Group I, and in patients with CP and in CPDM biopsies were collected from teeth undergoing extraction. Sections were prepared for immune histochemical staining with CD34. Results: Difference was observed in the average number of blood vessels when compared between HP, CP, and CPDM groups. Statistical significant difference was observed when the HP and CP groups and HP and CPDM groups were compared. Conclusion: The results of the study indicated that the number of blood vessels in gingival connective tissue is significantly higher in CP and CPDM patients.

  16. In vivo photoacoustic imaging of blood vessels with a pulsed laser diode

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Steenbergen, Wiendelt; van Leeuwen, Ton

    2006-01-01

    Photoacoustic imaging is a hybrid imaging modality that is based on the detection of acoustic waves generated by absorption of pulsed light by tissue chromophores such as hemoglobin in blood. For this technique, usually large and costly Q-switched Nd:YAG lasers are used. These lasers provide a pulse

  17. Ultrastructural analysis of small blood vessels in skin biopsies in CADASIL

    Directory of Open Access Journals (Sweden)

    Lačković Vesna

    2008-01-01

    Full Text Available Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL is an inherited small- and medium-artery disease of the brain caused by mutation of the Notch3 gene. Very often, this disease is misdiagnosed. We examined skin biopsies in two members of the first discovered Serbian family affected by CADASIL. Electron microscopy showed that skin blood vessels of both patients contain numerous deposits of granular osmiophilic material (GOM around vascular smooth muscle cells (VSMCs. We observed degeneration of VSMCs, reorganization of their cytoskeleton and dense bodies, disruption of myoendothelial contacts, and apoptosis. Our results suggest that the presence of GOM in small skin arteries represents a specific marker in diagnosis of CADASIL.

  18. Spatiotemporal image correlation analysis of blood flow in branched vessel networks of zebrafish embryos

    Science.gov (United States)

    Ceffa, Nicolo G.; Cesana, Ilaria; Collini, Maddalena; D'Alfonso, Laura; Carra, Silvia; Cotelli, Franco; Sironi, Laura; Chirico, Giuseppe

    2017-10-01

    Ramification of blood circulation is relevant in a number of physiological and pathological conditions. The oxygen exchange occurs largely in the capillary bed, and the cancer progression is closely linked to the angiogenesis around the tumor mass. Optical microscopy has made impressive improvements in in vivo imaging and dynamic studies based on correlation analysis of time stacks of images. Here, we develop and test advanced methods that allow mapping the flow fields in branched vessel networks at the resolution of 10 to 20 μm. The methods, based on the application of spatiotemporal image correlation spectroscopy and its extension to cross-correlation analysis, are applied here to the case of early stage embryos of zebrafish.

  19. Wrong theories on the origin of blood vessels: Polybus and De Natura Hominis.

    Science.gov (United States)

    Shoja, Mohammadali M; Tubbs, R Shane; Loukas, Marios; Ardalan, Mohammad R

    2008-06-06

    Polybus of Cos (approximately 400 B.C.) was the son-in-law and the successor of Hippocrates. He is credited with founding the school of Dogmatism, and writing "The Nature of Man" which was important in advancing the theory of the four body humors (humoralism). Some earlier scholars negated Polybus' role as an independent medical figure. However, Corpus Aristotelicum quoted him as having a unique theory regarding the body vasculature which stated that this system was composed of four pairs of blood vessels originating from the head and that these supplied the whole body. In an interpretation of this theory, we opined that numerological mysticism might have been the common motive for both Hippocrates' humoralism and Polybus' theory of the vasculature. A discussion on this issue is presented.

  20. [Blood Test Patterns for Blood Donors after Nucleic Acid Detection in the Blood Center].

    Science.gov (United States)

    Men, Shou-Shan; Lv, Lian-Zhi; Chen, Yuan-Feng; Han, Chun-Hua; Liu, Hong-Yu; Yan, Yan

    2017-12-01

    To investigate the blood test patterns for blood donors after nucleic acid detection in blood center. The collected blood samples after voluntary blood donors first were detected by conventional ELISA, then 31981 negative samples were detected via HBV/HCV/HIV combined nucleic acid test of 6 mixed samples(22716 cases) or single samples(9265 cases) by means of Roche cobas s201 instrument. The combined detection method as follows: the blood samples were assayed by conventional nucleic acid test of 6 mixed samples, at same time, 6 mixed samples were treated with polyethylene glycol precipitation method to concentrate the virus, then the nucleic acid test of blood samples was performed; the single detection method as follows: firstly the conventional nucleic acid test of single sample was performed, then the positive reactive samples after re-examination were 6-fold diluted to simulate the nucleic acid test of 6-mixed samples. The positive rate of positive samples detected by combined nucleic acid test, positive samples detected by nucleic acid test of mixed virus concentration and positive samples detected by single nucleic acid test was statistically analyzed. In addition, for HBV + persons the serological test yet should be performed. In 22 716 samples detected by nucleic acid test of 6 mixed samples (MP-6-NAT) , 9 cases were HBV + (0.40‰, 9/22716); at same time, the detection of same samples by nucleic acid test of mixed sample virus concentration showed 29 cases of HBV + (1.28‰, 29/22716). In 9265 samples detected by single nucleic acid test(ID-NAT) 12 cases showed HBV + (1.30‰, 12/9265), meanwhile the detection of these 12 samples with HBV + by 6-fold dilution for virus concentration found only 4 samples with HBV + . In serological qualified samples, ID-NAT unqualified rate was 1.28‰, which was higher than that of MP-6-NAT(0.4‰) (χ 2 =8.11, P0.05). In 41 samples with HBsAg - HBV DNA + detected by ELISA, 36 samples were confirmed to be occult HBV

  1. Factor V Leiden Is Associated with Higher Risk of Deep Venous Thrombosis of Large Blood Vessels

    Science.gov (United States)

    Arsov, Todor; Miladinova, Daniela; Spiroski, Mirko

    2006-01-01

    Aim To determine the prevalence of factor V Leiden mutation in patients with different presentation of venous thromboembolic disease and healthy individuals in the Republic of Macedonia. Methods The retrospective case-control study involved 190 patients with venous thromboembolic disease and 200 healthy individuals, who were screened for the presence of factor V Leiden mutation, using a polymerase chain reaction-restriction fragment length polymorphism method. The prevalence of factor V Leiden was analyzed according to the localization of thrombosis, presence of risk factors, and family history of thrombosis. The odds of deep venous thrombosis were calculated with respect to the presence of factor V Leiden mutation. Results The prevalence of factor V Leiden mutation among patients with venous thromboembolic disease was 21.1%, compared with 5.5% in the healthy individuals. Factor V Leiden positive patients had the first episode of deep venous thrombosis at a younger age, and the prevalence of the mutation was the highest among patients with a positive family history of thrombosis (33.9%, P = 0.003) and in patients with deep venous thrombosis affecting a large blood vessel (37.7%, P = 0.001). The prevalence of factor V Leiden mutation was lower in patients with calf deep venous thrombosis and primary thromboembolism (13.3% and 13.1%, respectively; P>0.05). The odds ratio for iliofemoral or femoral deep venous thrombosis in factor V Leiden carriers was 10.4 (95% confidence interval, 4.7-23.1). Conclusion The prevalence of factor V Leiden mutation was high in patients with venous thromboembolic disease and healthy individuals in the Republic of Macedonia. Factor V Leiden carriers have the highest odds of developing deep venous thrombosis affecting a large venous blood vessel. PMID:16758522

  2. Distinct mechanisms of relaxation to bioactive components from chamomile species in porcine isolated blood vessels.

    Science.gov (United States)

    Roberts, R E; Allen, S; Chang, A P Y; Henderson, H; Hobson, G C; Karania, B; Morgan, K N; Pek, A S Y; Raghvani, K; Shee, C Y; Shikotra, J; Street, E; Abbas, Z; Ellis, K; Heer, J K; Alexander, S P H

    2013-11-01

    German chamomile (Matricaria recutita L.), a widely-used herbal medicine, has been reported to have a wide range of biological effects, including smooth muscle relaxation. The aim of this study was to compare the effects of representative compounds from chamomile (apigenin, luteolin, (-)-α-bisabolol, farnesene, umbelliferone; 3-30 μM) on vascular tone using porcine coronary and splenic arteries mounted for isometric tension recording in isolated tissue baths and precontracted with the thromboxane-mimetic U46619. Apigenin, luteolin, and (-)-α-bisabolol produced slow, concentration-dependent relaxations in both the coronary and splenic arteries that were not blocked by inhibition of nitric oxide synthase or potassium channels. Removal of extracellular calcium inhibited the relaxations to all three compounds, and these compounds also inhibited calcium re-addition-evoked contractions, indicating that the relaxation response may be mediated through inhibition of calcium influx. Apigenin and luteolin, but not (-)-α-bisabolol, enhanced the relaxation to the nitric oxide donor sodium nitroprusside, indicating that apigenin and luteolin may act to regulate cyclic GMP levels. Umbelliferone produced a rapid, transient relaxation in the splenic artery, but not the coronary artery, that was inhibited by L-NAME and removal of the endothelium, suggesting an influence on nitric oxide production. Farnesene, at concentrations up to 30 μM, was without effect in either blood vessel. In conclusion, hydroxylated compounds (apigenin, luteolin and (-)-α-bisabolol) found in chamomile all caused a slow relaxation of isolated blood vessels through an effect on calcium influx. Umbelliferone, on the other hand, produced a rapid, transient relaxation dependent upon release of nitric oxide from the endothelium. © 2013.

  3. SDF-1 controls the muscle and blood vessel formation of the somite.

    Science.gov (United States)

    Abduelmula, Aisha; Huang, Ruijin; Pu, Qin; Tamamura, Hirokazu; Morosan-Puopolo, Gabriela; Brand-Saberi, Beate

    2016-01-01

    Stromal-cell-derived factor-1 (SDF-1), the only ligand of the chemokine receptor CXCR4, is involved in skeletal muscle development. However, its role in the proliferation, differentiation and migration of somite cells is not well understood. Here, we investigated its function during somite development in chicken embryos by using gain-of-function and loss-of-function experiments. Overexpression of SDF-1 was performed by electroporating SDF-1 constructs into the ventrolateral part of the somite, or by injecting SDF-1-expressing cells into the somites of stages HH14-16 chicken embryos. We found that enhanced SDF-1 signaling induced cell proliferation in the somite. This resulted in an increase in number of both myotomal and endothelial cells. In contrast, inhibition of SDF-1/CXCR4 signaling led to a reduction of myotomal cells. Injection of SDF-1 producing cells into the somite induced ectopic localization of myotomal cells in the sclerotome. Although many SDF-1-expressing somite cells colonized the limb, only a few of them developed into muscle cells. This resulted in a reduction of the limb muscle mass. This means that most myogenic progenitors were stopped on their migration towards the limb due to the high concentration of the SDF-1 signal in the somite. Most of the SDF-1-expressing somite cells found in the limb were of endothelial cell fate and they contributed to the increase in limb blood vessels. These results reveal that SDF-1 promotes the proliferation of both myogenic and angiogenic progenitor cells of the somite and controls myotome formation. Furthermore, SDF-1 controls muscle and blood vessel formation in the limb in different ways.

  4. Tumor blood vessel "normalization" improves the therapeutic efficacy of boron neutron capture therapy (BNCT) in experimental oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    D. W. Nigg

    2012-01-01

    We previously demonstrated the efficacy of BNCT mediated by boronophenylalanine (BPA) to treat tumors in a hamster cheek pouch model of oral cancer with no normal tissue radiotoxicity and moderate, albeit reversible, mucositis in precancerous tissue around treated tumors. It is known that boron targeting of the largest possible proportion of tumor cells contributes to the success of BNCT and that tumor blood vessel normalization improves drug delivery to the tumor. Within this context, the aim of the present study was to evaluate the effect of blood vessel normalization on the therapeutic efficacy and potential radiotoxicity of BNCT in the hamster cheek pouch model of oral cancer.

  5. THE INFLUINCE OF THE STAPHYLOCOCCUS INFECTION TO THE STRUCTURAL ORGANIZATION OF WISTAR RATS BRAIN AND CEREBRAL BLOOD VESSELS

    Directory of Open Access Journals (Sweden)

    Torianik I. I.

    2013-12-01

    Full Text Available In this article there are a dates about the influence of thestaphylococcus infection to the structural organization of Wistar rats brain and cerebral blood vessels in experiment. The purpose of the experiment’s are achieving by the seding staphylococcus infection means of the characterical structures of the brain and cerebralblood damages, that similar with the such in a human in a case of the development of a traditional clinic pathology.The results are evaluated to character of the morphological changes (brain cortex and cerebral blood vessels destructive and degenerative alterations,inflammatory processes.

  6. A fully automatic multiscale 3-dimensional Hessian-based algorithm for vessel detection in breast DCE-MRI.

    Science.gov (United States)

    Vignati, Anna; Giannini, Valentina; Bert, Alberto; Borrelli, Pasquale; De Luca, Massimo; Martincich, Laura; Sardanelli, Francesco; Regge, Daniele

    2012-12-01

    The objectives of this study were to develop a fully automatic method for detecting blood vessels in dynamic contrast-enhanced magnetic resonance imaging of the breast on the basis of a multiscale 3-dimensional Hessian-based algorithm and to evaluate the improvement in reducing the number of vessel voxels incorrectly classified as parenchymal lesions by a computer-aided diagnosis (CAD) system. The algorithm has been conceived to work on images obtained with different sequences, different acquisition parameters, such as the use of fat-saturation, and different contrast agents. The analysis was performed on 28 dynamic contrast-enhanced magnetic resonance imaging examinations, with 39 malignant (28 principal and 11 satellite) and 8 benign lesions, acquired at 2 centers using 2 different 1.5-T magnetic resonance scanners, radiofrequency coils, and contrast agents (14 studies from group A and 14 studies from group B). The method consists of 2 main steps: (a) the detection of linear structures on 3-dimensional images, with a multiscale analysis based on the second-order image derivatives and (b) the exclusion of non-vessel enhancements based on their morphological properties through the evaluation of the covariance matrix eigenvalues. To evaluate the algorithm performances, the identified vessels were converted into a 2-dimensional vasculature skeleton and then compared with manual tracking performed by an expert radiologist. When assessing the outcome of the algorithm performances in identifying vascular structures, the following terms must be considered: the correct-detection rate refers to pixels identified by both the algorithm and the radiologist, the missed-detection rate refers to pixels detected only by the radiologist, and the incorrect-detection rate refers to pixels detected only by the algorithm. The Wilcoxon rank sum test was used to assess differences between the performances of the 2 subgroups of images obtained from the different scanners. For the testing

  7. Predicting effects of blood flow rate and size of vessels in a vasculature on hyperthermia treatments using computer simulation.

    Science.gov (United States)

    Huang, Huang-Wen; Shih, Tzu-Ching; Liauh, Chihng-Tsung

    2010-03-26

    Pennes Bio Heat Transfer Equation (PBHTE) has been widely used to approximate the overall temperature distribution in tissue using a perfusion parameter term in the equation during hyperthermia treatment. In the similar modeling, effective thermal conductivity (Keff) model uses thermal conductivity as a parameter to predict temperatures. However the equations do not describe the thermal contribution of blood vessels. A countercurrent vascular network model which represents a more fundamental approach to modeling temperatures in tissue than do the generally used approximate equations such as the Pennes BHTE or effective thermal conductivity equations was presented in 1996. This type of model is capable of calculating the blood temperature in vessels and describing a vasculature in the tissue regions. In this paper, a countercurrent blood vessel network (CBVN) model for calculating tissue temperatures has been developed for studying hyperthermia cancer treatment. We use a systematic approach to reveal the impact of a vasculature of blood vessels against a single vessel which most studies have presented. A vasculature illustrates branching vessels at the periphery of the tumor volume. The general trends present in this vascular model are similar to those shown for physiological systems in Green and Whitmore. The 3-D temperature distributions are obtained by solving the conduction equation in the tissue and the convective energy equation with specified Nusselt number in the vessels. This paper investigates effects of size of blood vessels in the CBVN model on total absorbed power in the treated region and blood flow rates (or perfusion rate) in the CBVN on temperature distributions during hyperthermia cancer treatment. Also, the same optimized power distribution during hyperthermia treatment is used to illustrate the differences between PBHTE and CBVN models. Keff (effective thermal conductivity model) delivers the same difference as compared to the CBVN model. The

  8. Predicting effects of blood flow rate and size of vessels in a vasculature on hyperthermia treatments using computer simulation

    Directory of Open Access Journals (Sweden)

    Shih Tzu-Ching

    2010-03-01

    Full Text Available Abstract Background Pennes Bio Heat Transfer Equation (PBHTE has been widely used to approximate the overall temperature distribution in tissue using a perfusion parameter term in the equation during hyperthermia treatment. In the similar modeling, effective thermal conductivity (Keff model uses thermal conductivity as a parameter to predict temperatures. However the equations do not describe the thermal contribution of blood vessels. A countercurrent vascular network model which represents a more fundamental approach to modeling temperatures in tissue than do the generally used approximate equations such as the Pennes BHTE or effective thermal conductivity equations was presented in 1996. This type of model is capable of calculating the blood temperature in vessels and describing a vasculature in the tissue regions. Methods In this paper, a countercurrent blood vessel network (CBVN model for calculating tissue temperatures has been developed for studying hyperthermia cancer treatment. We use a systematic approach to reveal the impact of a vasculature of blood vessels against a single vessel which most studies have presented. A vasculature illustrates branching vessels at the periphery of the tumor volume. The general trends present in this vascular model are similar to those shown for physiological systems in Green and Whitmore. The 3-D temperature distributions are obtained by solving the conduction equation in the tissue and the convective energy equation with specified Nusselt number in the vessels. Results This paper investigates effects of size of blood vessels in the CBVN model on total absorbed power in the treated region and blood flow rates (or perfusion rate in the CBVN on temperature distributions during hyperthermia cancer treatment. Also, the same optimized power distribution during hyperthermia treatment is used to illustrate the differences between PBHTE and CBVN models. Keff (effective thermal conductivity model delivers the

  9. Accuracy and Precision of MR Blood Oximetry Based On the Long Paramagnetic Cylinder Approximation of Large Vessels

    Science.gov (United States)

    Langham, Michael C.; Magland, Jeremy F.; Epstein, Charles L.; Floyd, Thomas F.; Wehrli, Felix W.

    2009-01-01

    An accurate non-invasive method to measure hemoglobin oxygen saturation (%HbO2) of deep-lying vessels without catheterization would have many clinical applications. Quantitative MRI may be the only imaging modality that can address this difficult and important problem. MR susceptometry-based oximetry for measuring blood oxygen saturation in large vessels models the vessel as a long paramagnetic cylinder immersed in an external field. The intravascular magnetic susceptibility relative to surrounding muscle tissue is a function of HbO2 and can be quantified with a field mapping pulse sequence. In this work, the method’s accuracy and precision was investigated theoretically on the basis of an analytical expression for the arbitrarily oriented cylinder, as well as experimentally in phantoms and in vivo in the femoral artery and vein at 3T field strength. Errors resulting from vessel tilt, non-circularity of vessel cross-section, and induced magnetic field gradients were evaluated and methods for correction designed and implemented. Hemoglobin saturation was measured at successive vessel segments, differing in geometry such as eccentricity and vessel tilt but constant blood oxygen saturation levels, as a means to evaluate measurement consistency. The average standard error and coefficient of variation of measurements in phantoms were less than 2% with tilt correction alone, in agreement with theory, suggesting that high accuracy and reproducibility can be achieved while ignoring non-circularity for tilt angles up to about 30°. In vivo, repeated measurements of %HbO2 in the femoral vessels yielded a coefficient of variation of less than 5%. In conclusion, the data suggest that %HbO2 can be measured reproducibly in vivo in large vessels of the peripheral circulation on the basis of the paramagnetic cylinder approximation of the incremental field. PMID:19526517

  10. Use of sentinel-1 data for vessel detection in South African oceans: Early results

    CSIR Research Space (South Africa)

    Kleynhans, Waldo

    2015-08-01

    Full Text Available ) image acquired in Extra Wide (EW) mode over two of the busiest harbors in the country was used together with a standard Cell averaging Constant False Alarm Rate (CA-CFAR) detector to evaluate vessel detection performance for the two polarization modes...

  11. Lama1 mutations lead to vitreoretinal blood vessel formation, persistence of fetal vasculature, and epiretinal membrane formation in mice

    Directory of Open Access Journals (Sweden)

    Heng Céline

    2011-10-01

    Full Text Available Abstract Background Valuable insights into the complex process of retinal vascular development can be gained using models with abnormal retinal vasculature. Two such models are the recently described mouse lines with mutations in Lama1, an important component of the retinal internal limiting membrane (ILM. These mutants have a persistence of the fetal vasculature of vitreous (FVV but lack a primary retinal vascular plexus. The present study provides a detailed analysis of astrocyte and vascular development in these Lama1 mutants. Results Although astrocytes and blood vessels initially migrate into Lama1 mutant retinas, both traverse the peripapillary ILM into the vitreous by P3. Once in the vitreous, blood vessels anastomose with vessels of the vasa hyaloidea propria, part of the FVV, and eventually re-enter the retina where they dive to form the inner and outer retinal capillary networks. Astrocytes continue proliferating within the vitreous to form a dense mesh that resembles epiretinal membranes associated with persistent fetal vasculature and proliferative vitreoretinopathy. Conclusions Lama1 and a fully intact ILM are required for normal retinal vascular development. Mutations in Lama1 allow developing retinal vessels to enter the vitreous where they anastomose with vessels of the hyaloid system which persist and expand. Together, these vessels branch into the retina to form fairly normal inner retinal vascular capillary plexi. The Lama1 mutants described in this report are potential models for studying the human conditions persistent fetal vasculature and proliferative vitreoretinopathy.

  12. Blood Vessel Density in Basal Cell Carcinomas and Benign Trichogenic Tumors as a Marker for Differential Diagnosis in Dermatopathology

    International Nuclear Information System (INIS)

    Winter, J.; Kneitz, H.; Brocker, E. B.

    2011-01-01

    In order to get insight into the density of blood vessels in the stroma of benign and malignant trichogenic neoplasms, immuno histological quantification of CD 31 positive vessels was performed in 112 tumors, comprised of 50 BCCs of nodular (35) or morphoeic (15) growth patterns, 17 Pinkus' tumors, as well as 17 trichoepitheliomas of which 6 were desmoplastic, 8 trichofolliculomas, and 20 trichoblastomas. Methods. Vessel density was counted within the tumors, in the tumor-surrounding stroma, and, as a control, in the normal skin of the operation specimen. The results were compared using statistical methods. Results. Whereas, irrespective of the patients' age and location of tumors, the vessel density in normal skin showed no significant differences (8.8±2.7), the counts in the peritumoral stroma revealed significant differences between the different tumors investigated. The highest counts were obtained in BCC (24.7±6.7) and the lowest in benign trichogenic neoplasms (around 14) Pinkus' tumors revealed intermediate counts (19.7±6.6). The vessel densities within the tumors were generally low, and no correlation to the dignity was found. Conclusion. Determination of blood vessel density in the peritumoral stroma may be an additional parameter for differential diagnosis of trichogenic tumors of uncertain dignity.

  13. Detection of single-phase CTA occult vessel occlusions in acute ischemic stroke using CT perfusion-based wavelet-transformed angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kunz, Wolfgang G.; Sommer, Wieland H.; Meinel, Felix G.; Ertl-Wagner, Birgit; Thierfelder, Kolja M. [Ludwig-Maximilian-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Havla, Lukas; Dietrich, Olaf [Ludwig-Maximilian-University Hospital Munich, Josef Lissner Laboratory for Biomedical Imaging of the Institute for Clinical Radiology, Munich (Germany); Dorn, Franziska [Ludwig-Maximilian-University Hospital Munich, Department of Neuroradiology, Munich (Germany); Buchholz, Grete [Ludwig-Maximilian-University Hospital Munich, Department of Neurology, Munich (Germany)

    2017-06-15

    To determine the detection rate of intracranial vessel occlusions using CT perfusion-based wavelet-transformed angiography (waveletCTA) in acute ischemic stroke patients, in whom single-phase CTA (spCTA) failed to detect an occlusion. Subjects were selected from a cohort of 791 consecutive patients who underwent multiparametric CT including whole-brain CT perfusion. Inclusion criteria were (1) significant cerebral blood flow (CBF) deficit, (2) no evidence of vessel occlusion on spCTA and (3) follow-up-confirmed acute ischemic infarction. waveletCTA was independently analysed by two readers regarding presence and location of vessel occlusions. Logistic regression analysis was performed to identify predictors of waveletCTA-detected occlusions. Fifty-nine patients fulfilled the inclusion criteria. Overall, an occlusion was identified using waveletCTA in 31 (52.5 %) patients with negative spCTA. Out of 47 patients with middle cerebral artery infarction, 27 occlusions (57.4 %) were detected by waveletCTA, mainly located in the M2 (15) and M3 segments (8). The presence of waveletCTA-detected occlusions was associated with larger CBF deficit volumes (odds ratio (OR) = 1.335, p = 0.010) and shorter times from symptom onset (OR = 0.306, p = 0.041). waveletCTA is able to detect spCTA occult vessel occlusions in about half of acute ischemic stroke patients and may potentially identify more patients eligible for endovascular therapy. (orig.)

  14. Ultrasound sonication with microbubbles disrupts blood vessels and enhances tumor treatments of anticancer nanodrug

    Directory of Open Access Journals (Sweden)

    Lin CY

    2012-04-01

    Full Text Available Chung-Yin Lin1*, Hsiao-Ching Tseng1*, Heng-Ruei Shiu1, Ming-Fang Wu2, Cheng-Ying Chou3, Win-Li Lin1,41Institute of Biomedical Engineering, 2Laboratory Animal Center, 3Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, Taipei, Taiwan; 4Division of Medical Engineering Research, National Health Research Institutes, Miaoli, Taiwan*These authors contributed equally to this workAbstract: Ultrasound (US sonication with microbubbles (MBs has the potential to disrupt blood vessels and enhance the delivery of drugs into the sonicated tissues. In this study, mouse ear tumors were employed to investigate the therapeutic effects of US, MBs, and pegylated liposomal doxorubicin (PLD on tumors. Tumors started to receive treatments when they grew up to about 15 mm3 (early stage with injection of PLD 10 mg/kg, or up to 50 mm3 (medium stage with PLD 6 (or 4 mg/kg. Experiments included the control, PLD alone, PLD + MBs + US, US alone, and MBs + US groups. The procedure for the PLD + MBs + US group was that PLD was injected first, MB (SonoVue injection followed, and then US was immediately sonicated on the tumor. The results showed that: (1 US sonication with MBs was always able to produce a further hindrance to tumor growth for both early and medium-stage tumors; (2 for the medium-stage tumors, 6 mg/kg PLD alone was able to inhibit their growth, while it did not work for 4 mg/kg PLD alone; (3 with the application of MBs + US, 4 mg/kg PLD was able to inhibit the growth of medium-stage tumors; (4 for early stage tumors after the first treatment with a high dose of PLD alone (10 mg/kg, the tumor size still increased for several days and then decreased (a biphasic pattern; (5 MBs + US alone was able to hinder the growth of early stage tumors, but unable to hinder that of medium stage tumors. The results of histological examinations and blood perfusion measurements indicated that the application of MBs + US disrupts the tumor blood

  15. The relationship of retinal vessel diameters and fractal dimensions with blood pressure and cardiovascular risk factors.

    Directory of Open Access Journals (Sweden)

    Pengli Zhu

    Full Text Available BACKGROUND: This study aimed to investigate the correlation between quantitative retinal vascular parameters such as central retinal arteriolar equivalent (CRAE and retinal vascular fractal dimension (D(f, and cardiovascular risk factors in the Chinese Han population residing in the in islands of southeast China. METHODOLOGY/PRINCIPLE FINDINGS: In this cross-sectional study, fundus photographs were collected and semi-automated analysis software was used to analyze retinal vessel diameters and fractal dimensions. Cardiovascular risk factors such as relevant medical history, blood pressure (BP, lipids, and blood glucose data were collected. Subjects had a mean age of 51.9 ± 12.0 years and included 812 (37.4% males and 1,357 (62.6% females. Of the subjects, 726 (33.5% were overweight, 226 (10.4% were obese, 272 (12.5% had diabetes, 738 (34.0% had hypertension, and 1,156 (53.3% had metabolic syndrome. After controlling for the effects of potential confounders, multivariate analyses found that age (β = 0.06, P = 0.008, sex (β = 1.33, P = 0.015, mean arterial blood pressure (β = -0.12, P<0.001, high-sensitivity C-reactive protein (β = -0.22, P = 0.008, and CRVE (β = 0.23, P<0.001 were significantly associated with CRAE. Age (β = -0.0012, P < 0.001, BP classification (prehypertension: β = -0.0075, P = 0.014; hypertension: β = -0.0131, P = 0.002, and hypertension history (β = -0.0007, P = 0.009 were significantly associated with D(f. CONCLUSIONS/SIGNIFICANCE: D(f exhibits a stronger association with BP than CRAE. Thus, D(f may become a useful indicator of cardiovascular risk.

  16. Role of the 3-Vessel and Trachea View in Antenatal Detection of Tetralogy of Fallot.

    Science.gov (United States)

    Palatnik, Anna; Grobman, William A; Cohen, Leeber S; Dungan, Jeffrey S; Gotteiner, Nina L

    2016-08-01

    Prenatal diagnosis of tetralogy of Fallot remains less frequent compared to other major congenital heart defects. In this study, we examined how often the 3-vessel and trachea view was abnormal in a large series of prenatally diagnosed cases of tetralogy of Fallot. In addition, we compared its sensitivity to that of the traditional outflow tract views for detection of tetralogy of Fallot. We found that both views were abnormal in all fetuses with tetralogy of Fallot, showing reversed aortic-to-pulmonary valve and aortic arch isthmus-to-ductus arteriosus ratios in the outflow tract and 3-vessel and trachea views, respectively. However, as a single measured marker, the enlarged aortic arch isthmus on the 3-vessel and trachea view appears to be the most sensitive for tetralogy of Fallot.

  17. Tests of the geometrical description of blood vessels in a thermal model using counter-current geometries

    NARCIS (Netherlands)

    van Leeuwen, G. M.; Kotte, A. N.; Crezee, J.; Lagendijk, J. J.

    1997-01-01

    We have developed a thermal model, for use in hyperthermia treatment planning, in which blood vessels are described as geometrical objects; 3D curves with associated diameters. For the calculation of the heat exchange with the tissue an analytic result is used. To arrive at this result some

  18. Antibody-linked drug destroys tumor cells and tumor blood vessels in many types of cancer | Center for Cancer Research

    Science.gov (United States)

    A team led by Brad St. Croix, Ph.D., Senior Associate Scientist, Mouse Cancer Genetics Program, has developed an antibody-drug conjugate (ADC) that destroys both tumor cells and the blood vessels that nourish them. The drug significantly shrank breast tumors, colon tumors and several other types of cancer and prolonged survival. Learn more...  

  19. Does Physical Fitness Buffer the Relationship between Psychosocial Stress, Retinal Vessel Diameters, and Blood Pressure among Primary Schoolchildren?

    Science.gov (United States)

    Gerber, Markus; Endes, Katharina; Herrmann, Christian; Colledge, Flora; Brand, Serge; Donath, Lars; Faude, Oliver; Pühse, Uwe; Hanssen, Henner; Zahner, Lukas

    2016-01-01

    Background . Strong evidence exists showing that psychosocial stress plays an important part in the development of cardiovascular diseases. Because physical inactivity is associated with less favourable retinal vessel diameter and blood pressure profiles, this study explores whether physical fitness is able to buffer the negative effects of psychosocial stress on retinal vessel diameters and blood pressure in young children. Methods . 325 primary schoolchildren (51% girls, M age = 7.28 years) took part in this cross-sectional research project. Retinal arteriolar diameters, retinal venular diameters, arteriolar to venular ratio, and systolic and diastolic blood pressure were assessed in all children. Interactions terms between physical fitness (performance in the 20 m shuttle run test) and four indicators of psychosocial stress (parental reports of critical life events, family, peer and school stress) were tested in a series of hierarchical regression analyses. Results . Critical life events and family, peer, and school-related stress were only weakly associated with retinal vessel diameters and blood pressure. No support was found for a stress-buffering effect of physical fitness. Conclusion . More research is needed with different age groups to find out if and from what age physical fitness can protect against arteriolar vessel narrowing and the occurrence of other cardiovascular disease risk factors.

  20. "Sausage-string" appearance of arteries and arterioles can be caused by an instability of the blood vessel wall

    DEFF Research Database (Denmark)

    Jacobsen, Jens Christian Brings; Beierholm, Ulrik; Mikkelsen, Rene

    2002-01-01

    observed experimentally. Most importantly, it suggests that the "sausaging" phenomenon is neither caused by a mechanical failure of the vessel wall due to a high blood pressure nor is it due to standing pressure waves caused by the beating of the heart. Rather, it is the expression of a general instability...

  1. Did antepartum hypoxic insult caused by fetal vessel thrombosis influence the procalcitonin level in umbilical blood? A case report.

    Science.gov (United States)

    Kaneko, Masatoki; Yamauchi, Aya; Yamashita, Rie; Sato, Yuichiro; Kodama, Yuki; Sameshima, Hiroshi

    2015-11-01

    We report a case of marked elevation of the procalcitonin level in umbilical blood and neonatal blood at birth. The mother did not perceive fetal motion. Antepartum fetal heart rate monitoring showed a loss of variability and absence of acceleration. No fetal breathing movement, fetal movement, or fetal tone were observed by ultrasonography. The female neonate was delivered by cesarean section at 25 weeks of gestation, with birthweight 774 g. The umbilical arterial pH value at birth was 7.29. Mild elevation in interleukin-6 and tumor necrosis factor-α in umbilical blood were observed. Cytochrome c showed a high level in umbilical and neonatal blood at birth. Placental histopathology revealed multiple fetal vessel thrombosis in the large stem villi and chorionic vessels. The neonate showed no infectious signs throughout the neonatal period. Computed tomography at 3 months of age revealed atrophy in the cerebrum and cerebellum. At 1 year after birth, the infant showed spastic quadriplegia. In this case, antepartum asphyxia due to fetal vessel thrombosis may have influenced the elevation of procalcitonin level in umbilical blood and neonatal blood at birth. © 2015 Japan Society of Obstetrics and Gynecology.

  2. A new resorbable device for ligation of blood vessels - A pilot study.

    Science.gov (United States)

    Höglund, Odd V; Hagman, Ragnvi; Olsson, Kerstin; Mindemark, Jonas; Borg, Niklas; Lagerstedt, Anne-Sofie

    2011-07-08

    During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency. The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs. The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, n = 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, n = 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and

  3. [Aetiology and pathogenesis of damages to blood vessels in drug addicts].

    Science.gov (United States)

    Sultanaliev, T A; Tursynbaev, S E; Ivakin, V M

    2007-01-01

    The article deals with the problems concerning aetiology and pathogenesis of damages to blood vessels in patients practicing parenteral administration of surrogates of narcotic substances. In order to clinically and experimentally study the pattern of morphological alterations in the area of narcotic substances administration and to work out an appropriate classification of the forms and stages of development of the pathological process, the authors analysed the clinical course of vascular lesions and complications thereof in a total of 244 drug abusers having parenterally administered surrogates of narcotic substances and undergoing treatment at the Department of Vascular Surgery of the Municipal Clinical Hospital of the city of Almaty. Additionally, experimental studies were carried out on 16 rabbits with the induced model of parenteral administration of surrogates of narcotic substances, thus making it possible to study the degree of their effect and to confirm the theory of a chemical impact of the homemade drugs on the vascular wall. The findings of the carried out studies enabled us to single out the following clinical stages of vascular lesions: stage I - the initial stage of cicatricial-and-ulcerous lesions formation, stage II - formation of cutaneous-and-vascular fistulas, stage III - the stage of complications characterized by development of health-hazardous vascular lesions, i. e., arterial and venous thromboses of the major vessels, as well as arrosive bleedings. It was noted that more than 50% of patients were admitted to the clinic presenting with the third stage of vascular lesions. The experimental part of the study included 64 experiments on 16 rabbits (one experiment per each paw of the animal). The laboratory animals were subdivided into three groups. The first experimental group consisted of the rabbits with a mechanically inflicted injury to the vessels. The second and third experimental groups were composed of the rabbits having received

  4. Evidence of Flicker-Induced Functional Hyperaemia in the Smallest Vessels of the Human Retinal Blood Supply.

    Directory of Open Access Journals (Sweden)

    Angelina Duan

    Full Text Available Regional changes in blood flow are initiated within neural tissue to help fuel local differences in neural activity. Classically, this response was thought to arise only in larger arterioles and venules. However, recently, it has been proposed that a the smallest vessels of the circulation make a comparable contribution, and b the response should be localised intermittently along such vessels, due to the known distribution of contractile mural cells. To assess these hypotheses in human neural tissue in vivo, we imaged the retinal microvasculature (diameters 3-28 μm non-invasively, using adaptive optics, before and after delivery of focal (360 μm patches of flickering visible light. Our results demonstrated a definite average response in 35% of all vessel segments analysed. In these responding vessels, the magnitude of proportional dilation (mean ± SEM for pre-capillary arterioles 13 ± 5%, capillaries 31 ± 8%, and post-capillary venules 10 ± 3% is generally far greater than the magnitudes we and others have measured in the larger retinal vessels, supporting proposition a above. The dilations observed in venules were unexpected based on previous animal work, and may be attributed either to differences in stimulus or species. Response heterogeneity across the network was high; responses were also heterogeneous along individual vessels (45% of vessel segments showed demonstrable locality in their response. These observations support proposition b above. We also observed a definite average constriction across 7% of vessel segments (mean ± SEM constriction for capillaries -16 ± 3.2%, and post-capillary venules -18 ± 12%, which paints a picture of dynamic redistribution of flow throughout the smallest vessel networks in the retina in response to local, stimulus-driven metabolic demand.

  5. Rapid sealing of porcine renal blood vessels, ex vivo, using a high power, 1470-nm laser, and laparoscopic prototype

    Science.gov (United States)

    Hardy, Luke A.; Hutchens, Thomas C.; Larson, Eric R.; Gonzalez, David A.; Chang, Chun-Hung; Nau, William H.; Fried, Nathaniel M.

    2017-05-01

    Energy-based, radiofrequency (RF) and ultrasonic (US) devices currently provide rapid sealing of blood vessels during laparoscopic procedures. We are exploring infrared lasers as an alternate energy modality for vessel sealing, capable of generating less collateral thermal damage. Previous studies demonstrated feasibility of sealing vessels in an in vivo porcine model using a 1470-nm laser. However, the initial prototype was designed for testing in open surgery and featured tissue clasping and light delivery mechanisms incompatible with laparoscopic surgery. In this study, a laparoscopic prototype similar to devices currently in surgical use was developed, and performance tests were conducted on porcine renal blood vessels, ex vivo. The 5-mm outer-diameter laparoscopic prototype featured a traditional Maryland jaw configuration that enables tissue manipulation and blunt dissection. Laser energy was delivered through a 550-μm-core-diameter optical fiber with side-delivery from the lower jaw and beam dimensions of 18-mm length×1.2-mm width. The 1470-nm diode laser delivered 68 W with 3-s activation time, consistent with vessel seal times associated with RF and US-based devices. A total of 69 fresh porcine renal vessels with mean diameter of 3.3±1.7 mm were tested, ex vivo. Vessels smaller than 5-mm diameter were consistently sealed (48/51) with burst pressures greater than malignant hypertension blood pressure (180 mmHg), averaging 1038±474 mmHg. Vessels larger than 5 mm were not consistently sealed (6/18), yielding burst pressures of only 174±221 mmHg. Seal width, thermal damage zone, and thermal spread averaged 1.7±0.8, 3.4±0.7, and 1.0±0.4 mm, respectively. Results demonstrated that the 5-mm optical laparoscopic prototype consistently sealed vessels less than 5-mm diameter with low thermal spread. Further in vivo studies are planned to test the performance across a variety of vessels and tissues.

  6. Inter-method agreement in retinal blood vessels diameter analysis between Dynamic Vessel Analyzer and optical coherence tomography.

    Science.gov (United States)

    Benatti, Lucia; Corvi, Federico; Tomasso, Livia; Mercuri, Stefano; Querques, Lea; Ricceri, Fulvio; Bandello, Francesco; Querques, Giuseppe

    2017-06-01

    To analyze the inter-methods agreement in arteriovenous ratio (AVR) evaluation between spectral-domain optical coherence tomography (SD-OCT) and Dynamic Vessel Analyzer (DVA). Healthy volunteers underwent DVA and SD-OCT examination. AVR was measured by SD-OCT using the four external lines of the optic nerve head-centered 7-line cube and by DVA using an automated AVR estimation. The mean AVR was calculated, twice, separately by two independent readers for each tool. Twenty-two eyes of 11 healthy subjects (five women and six men, mean age 35) were included. AVR analysis by DVA showed high inter-observer agreement between reader 1 and 2, and high intra-observer agreement for both reader 1 and reader 2. With regard to AVR analysis on SD-OCT, we found high inter-observer agreement between reader 1 and 2, and low intra-observer agreement for reader 2 but high intra-observer agreement for reader 1. Overall, the mean AVR measured on SD-OCT turned out to be significantly higher than mean AVR measured through DVA (reader 1, 0.9023 ± 0.06 vs 0.8036 ± 0.08; p DVA and SD-OCT). We found significant difference in the two noninvasive methods for AVR measurement, with a tendency for SD-OCT to overestimate retinal vascular caliber in comparison to DVA. This may be useful for achieving greater accuracy in the evaluation of retinal vessel in ocular as well as systemic diseases.

  7. Correlations Between the Density of Tryptase Positive Mast Cells (DMCT and that of New Blood Vessels (CD105+ in Patients with Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Micu Gianina Viorica

    2016-06-01

    Full Text Available Mast cells proteases, tryptase and chymase are directly involved in the growth and progression of solid tumors due to their important role in tumor angiogenesis. We examined the density of tryptase positive mast cells and the mean density of new blood vessels in gastric malignant tumors of patients with and without Helicobacter pylori infection, using immunohistochemical staining for tryptase (for mast cells and CD 105 (for new vessels. Tryptase and CD 105 expression was detected in gastrectomy specimens. In this study, mast cell density correlates with angiogenesis and the growth and progression of gastric cancer. It also shows that the participation of Helicobacter pylori infection in the growth and progress of gastric neoplasia is due to an increase of peritumoral angiogenesis, with subsequent local and distant tumor spread and perivascular growth, but without perineural and nodal involvement.

  8. X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Lee, Sang Joon

    2016-01-18

    X-ray PIV measurement is a noninvasive approach to measure opaque blood flows. However, it is not easy to measure real pulsatile blood flows in the blood vessels located at deep position of the body, because the surrounding tissues significantly attenuate the contrast of X-ray images. This study investigated the effect of surrounding tissues on X-ray beam attenuation by measuring the velocity fields of blood flows in deep vessels of a live rat. The decrease in image contrast was minimized by employing biocompatible CO2 microbubbles as tracer particles. The maximum measurable velocity of blood flows in the abdominal aorta of a rat model was found through comparative examination between the PIV measurement accuracy and the level of image contrast according to the input flow rate. Furthermore, the feasibility of using X-ray PIV to accurately measure in vivo blood flows was demonstrated by determining the velocity field of blood flows in the inferior vena cava of a rat. This study may serve as a reference in conducting in vivo X-ray PIV measurements of pulsatile blood flows in animal disease models and investigating hemodynamic characteristics and circulatory vascular diseases.

  9. Fast Vessel Detection in Gaofen-3 SAR Images with Ultrafine Strip-Map Mode.

    Science.gov (United States)

    Pan, Zongxu; Liu, Lei; Qiu, Xiaolan; Lei, Bin

    2017-07-05

    This study aims to detect vessels with lengths ranging from about 70 to 300 m, in Gaofen-3 (GF-3) SAR images with ultrafine strip-map (UFS) mode as fast as possible. Based on the analysis of the characteristics of vessels in GF-3 SAR imagery, an effective vessel detection method is proposed in this paper. Firstly, the iterative constant false alarm rate (CFAR) method is employed to detect the potential ship pixels. Secondly, the mean-shift operation is applied on each potential ship pixel to identify the candidate target region. During the mean-shift process, we maintain a selection matrix recording which pixels can be taken, and these pixels are called as the valid points of the candidate target. The l 1 norm regression is used to extract the principal axis and detect the valid points. Finally, two kinds of false alarms, the bright line and the azimuth ambiguity, are removed by comparing the valid area of the candidate target with a pre-defined value and computing the displacement between the true target and the corresponding replicas respectively. Experimental results on three GF-3 SAR images with UFS mode demonstrate the effectiveness and efficiency of the proposed method.

  10. Effects of pomegranate extract on blood flow and vessel diameter after high-intensity exercise in young, healthy adults.

    Science.gov (United States)

    Roelofs, Erica J; Smith-Ryan, Abbie E; Trexler, Eric T; Hirsch, Katie R; Mock, Meredith G

    2017-04-01

    The effects of pomegranate extract (PE) supplementation were evaluated on high-intensity exercise performance, blood flow, vessel diameter, oxygen saturation (SPO 2 ), heart rate (HR), and blood pressure (BP). In a randomized, crossover design, nineteen recreationally resistance-trained participants were randomly assigned to PE (1000 mg) or placebo (PL), which were consumed 30 min prior to a repeated sprint ability (RSA) test and repetitions to fatigue (RTF) on bench and leg press. The RSA consisted of ten six-second sprints on a friction-loaded cycle ergometer with 30 s recovery. Brachial artery blood flow and vessel diameter were assessed by ultrasound. Blood flow, vessel diameter, SPO 2 , HR, and BP were assessed at baseline, 30 min post ingestion, immediately post exercise (IPost), and 30 min post exercise (30minPost). With PE, blood flow significantly increased IPost RSA (mean difference = 18.49 mL min -1 ; P exercise performance enhancement from increased delivery of substrates and oxygen. The acute timing and capsule form of PE may be advantageous to athletic populations due to ergogenic effects, taste, and convenience.

  11. Specific Accumulation of Tumor-Derived Adhesion Factor in Tumor Blood Vessels and in Capillary Tube-Like Structures of Cultured Vascular Endothelial Cells

    Science.gov (United States)

    Akaogi, Kotaro; Okabe, Yukie; Sato, Junji; Nagashima, Yoji; Yasumitsu, Hidetaro; Sugahara, Kazuyuki; Miyazaki, Kaoru

    1996-08-01

    Tumor-derived adhesion factor (TAF) was previously identified as a cell adhesion molecule secreted by human bladder carcinoma cell line EJ-1. To elucidate the physiological function of TAF, we examined its distribution in human normal and tumor tissues. Immunochemical staining with an anti-TAF monoclonal antibody showed that TAF was specifically accumulated in small blood vessels and capillaries within and adjacent to tumor nests, but not in those in normal tissues. Tumor blood vessel-specific staining of TAF was observed in various human cancers, such as esophagus, brain, lung, and stomach cancers. Double immunofluorescent staining showed apparent colocalization of TAF and type IV collagen in the vascular basement membrane. In vitro experiments demonstrated that TAF preferentially bound to type IV collagen among various extracellular matrix components tested. In cell culture experiments, TAF promoted adhesion of human umbilical vein endothelial cells to type IV collagen substrate and induced their morphological change. Furthermore, when the endothelial cells were induced to form capillary tube-like structures by type I collagen, TAF and type IV collagen were exclusively detected on the tubular structures. The capillary tube formation in vitro was prevented by heparin, which inhibited the binding of TAF to the endothelial cells. These results strongly suggest that TAF contributes to the organization of new capillary vessels in tumor tissues by modulating the interaction of endothelial cells with type IV collagen.

  12. Detection of Atrial Fibrillation Among Patients With Stroke Due to Large or Small Vessel Disease: A Meta-Analysis.

    Science.gov (United States)

    Demeestere, Jelle; Fieuws, Steffen; Lansberg, Maarten G; Lemmens, Robin

    2016-09-26

    Recent trials have demonstrated that extended cardiac monitoring increases the yield of paroxysmal atrial fibrillation (AF) detection in patients with cryptogenic stroke. The utility of extended cardiac monitoring is uncertain among patients with stroke caused by small and large vessel disease. We conducted a meta-analysis to estimate the yield of AF detection in this population. We searched PubMed, Cochrane, and SCOPUS databases for studies on AF detection in stroke patients and excluded studies restricted to patients with cryptogenic stroke or transient ischemic attack. We abstracted AF detection rates for 3 populations grouped by stroke etiology: large vessel stroke, small vessel stroke, and stroke of undefined etiology (a mixture of cryptogenic, small vessel, large vessel, and other stroke etiologies). Our search yielded 30 studies (n=5687). AF detection rates were similar in patients with large vessel (2.2%, 95% CI 0.3-5.5; n=830) and small vessel stroke (2.4%, 95% CI 0.4-6.1; n=520). No studies had a monitoring duration longer than 7 days. The yield of AF detection in the undefined stroke population was higher (9.2%; 95% CI 7.1-11.5) compared to small vessel stroke (P=0.02) and large vessel stroke (P=0.02) populations. AF detection rate is similar in patients with small and large vessel strokes (2.2-2.4%). Because no studies reported on extended monitoring (>7 days) in these stroke populations, we could not estimate the yield of AF detection with long-term cardiac monitoring. Randomized controlled trials are needed to examine the utility of AF detection with long-term cardiac monitoring (>7 days) in this patient population. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  13. Cellular transport of subretinal material into choroidal and scleral blood vessels: an electron microscopic study.

    Science.gov (United States)

    Peters, S; Kayatz, P; Kociok, N; Heimann, K; Schraermeyer, U

    1999-12-01

    The fate of indigestible material injected into the subretinal space of rats was investigated. The non-toxic dye Monastral Blue (MB), which cannot be digested within the lysosomal compartment, was injected transsclerally into the subretinal space of Long Evans and Wistar rats. After 5 and 12 days respectively the eyes were enucleated and examined by light and electron microscopy. Cryo sections were made of eyes 5 days after MB injection for the application of immunohistochemical techniques using markers for epithelial cells (cytokeratin) and macrophages (ED 1). Retina, choroid and sclera were not altered in their morphology in the circumference of the MB-containing bubble generated by subretinal injection. After both 5 and 12 days no injected material was found extracellularly in the subretinal space. Especially high amounts of MB were found, in particular 5 days after injection, in lysosomes and melanosomes of RPE cells as well as in cells between choroidal melanocytes. Cells containing MB were seen in contact with choroidal and scleral blood vessels. These MB-containing cells in the choroid and in the sclera were positive for macrophage antibodies. Subretinal injection was confirmed as a suitable method for placing fluids into the subretinal space without affecting the morphology of the retina. Subretinal injected material was shown to be incorporated into lysosomes and melanosomes of RPE cells. The injected material was subsequently transported through Bruch's membrane to be finally removed from the eye via choroidal and scleral veins, the process involving macrophages.

  14. Thermal expansion of vitrified blood vessels permeated with DP6 and synthetic ice modulators.

    Science.gov (United States)

    Eisenberg, David P; Taylor, Michael J; Jimenez-Rios, Jorge L; Rabin, Yoed

    2014-06-01

    This study provides thermal expansion data for blood vessels permeated with the cryoprotective cocktail DP6, when combined with selected synthetic ice modulators (SIMs): 12% polyethylene glycol 400, 6% 1,3-cyclohexanediol, and 6% 2,3-butanediol. The general classification of SIMs includes molecules that modulate ice nucleation and growth, or possess properties of stabilizing the amorphous state, by virtue of their chemical structure and at concentrations that are not explained on a purely colligative basis. The current study is part of an ongoing effort to characterize thermo-mechanical effects on structural integrity of cryopreserved materials, where thermal expansion is the driving mechanism to thermo-mechanical stress. This study focuses on the lower part of the cryogenic temperature range, where the cryoprotective agent (CPA) behaves as a solid for all practical applications. By combining results obtained in the current study with literature data on the thermal expansion in the upper part of the cryogenic temperature range, unified thermal expansion curves are presented. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Thermal Expansion of Vitrified Blood Vessels Permeated with DP6 and Synthetic Ice Modulators

    Science.gov (United States)

    Eisenberg, David P.; Taylor, Michael J.; Jimenez-Rios, Jorge L.; Rabin, Yoed

    2014-01-01

    This study provides thermal expansion data for blood vessels permeated with the cryoprotective cocktail DP6, when combined with selected synthetic ice modulators (SIMs): 12% polyethylene glycol 400, 6% 1,3-cyclohexanediol, and 6% 2,3-butanediol. The general classification of SIMs includes molecules that modulate ice nucleation and growth, or possess properties of stabilizing the amorphous state, by virtue of their chemical structure and at concentrations that are not explained on a purely colligative basis. The current study is part of an ongoing effort to characterize thermo-mechanical effects on structural integrity of cryopreserved materials, where thermal expansion is the driving mechanism to thermo-mechanical stress. This study focuses on the lower part of the cryogenic temperature range, where the cryoprotective agent (CPA) behaves as a solid for all practical applications. By combining results obtained in the current study with literature data on the thermal expansion in the upper part of the cryogenic temperature range, unified thermal expansion curves are presented. PMID:24769313

  16. Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com; Ierardi, Anna Maria, E-mail: amierardi@yahoo.it; Duka, Ejona, E-mail: ejonaduka@hotmail.com [Insubria University, Department of Radiology, Interventional Radiology (Italy); Radaelli, Alessandro, E-mail: alessandro.radaelli@philips.com [Philips Healthcare (Netherlands); Floridi, Chiara, E-mail: chiara.floridi@gmail.com [Insubria University, Department of Radiology, Interventional Radiology (Italy); Bacuzzi, Alessandro, E-mail: alessandro.bacuzzi@ospedale.varese.it [University of Insubria, Anaesthesia and Palliative Care (Italy); Bucourt, Maximilian de, E-mail: maximilian.de-bucourt@charite.de [Charité - University Medicine Berlin, Department of Radiology (Germany); Marchi, Giuseppe De, E-mail: giuseppedemarchi@email.it [Insubria University, Department of Radiology, Interventional Radiology (Italy)

    2016-04-15

    BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

  17. Usefulness of Cone-Beam Computed Tomography and Automatic Vessel Detection Software in Emergency Transarterial Embolization

    International Nuclear Information System (INIS)

    Carrafiello, Gianpaolo; Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro; Floridi, Chiara; Bacuzzi, Alessandro; Bucourt, Maximilian de; Marchi, Giuseppe De

    2016-01-01

    BackgroundThis study was designed to evaluate the utility of dual phase cone beam computed tomography (DP-CBCT) and automatic vessel detection (AVD) software to guide transarterial embolization (TAE) of angiographically challenging arterial bleedings in emergency settings.MethodsTwenty patients with an arterial bleeding at computed tomography angiography and an inconclusive identification of the bleeding vessel at the initial 2D angiographic series were included. Accuracy of DP-CBCT and AVD software were defined as the ability to detect the bleeding site and the culprit arterial bleeder, respectively. Technical success was defined as the correct positioning of the microcatheter using AVD software. Clinical success was defined as the successful embolization. Total volume of iodinated contrast medium and overall procedure time were registered.ResultsThe bleeding site was not detected by initial angiogram in 20 % of cases, while impossibility to identify the bleeding vessel was the reason for inclusion in the remaining cases. The bleeding site was detected by DP-CBCT in 19 of 20 (95 %) patients; in one case CBCT-CT fusion was required. AVD software identified the culprit arterial branch in 18 of 20 (90 %) cases. In two cases, vessel tracking required manual marking of the candidate arterial bleeder. Technical success was 95 %. Successful embolization was achieved in all patients. Mean contrast volume injected for each patient was 77.5 ml, and mean overall procedural time was 50 min.ConclusionsC-arm CBCT and AVD software during TAE of angiographically challenging arterial bleedings is feasible and may facilitate successful embolization. Staff training in CBCT imaging and software manipulation is necessary.

  18. Vessel segmentation in screening mammograms

    Science.gov (United States)

    Mordang, J. J.; Karssemeijer, N.

    2015-03-01

    Blood vessels are a major cause of false positives in computer aided detection systems for the detection of breast cancer. Therefore, the purpose of this study is to construct a framework for the segmentation of blood vessels in screening mammograms. The proposed framework is based on supervised learning using a cascade classifier. This cascade classifier consists of several stages where in each stage a GentleBoost classifier is trained on Haar-like features. A total of 30 cases were included in this study. In each image, vessel pixels were annotated by selecting pixels on the centerline of the vessel, control samples were taken by annotating a region without any visible vascular structures. This resulted in a total of 31,000 pixels marked as vascular and over 4 million control pixels. After training, the classifier assigns a vesselness likelihood to the pixels. The proposed framework was compared to three other vessel enhancing methods, i) a vesselness filter, ii) a gaussian derivative filter, and iii) a tubeness filter. The methods were compared in terms of area under the receiver operating characteristics curves, the Az values. The Az value of the cascade approach is 0:85. This is superior to the vesselness, Gaussian, and tubeness methods, with Az values of 0:77, 0:81, and 0:78, respectively. From these results, it can be concluded that our proposed framework is a promising method for the detection of vessels in screening mammograms.

  19. An automated vessel segmentation of retinal images using multiscale vesselness

    International Nuclear Information System (INIS)

    Ben Abdallah, M.; Malek, J.; Tourki, R.; Krissian, K.

    2011-01-01

    The ocular fundus image can provide information on pathological changes caused by local ocular diseases and early signs of certain systemic diseases, such as diabetes and hypertension. Automated analysis and interpretation of fundus images has become a necessary and important diagnostic procedure in ophthalmology. The extraction of blood vessels from retinal images is an important and challenging task in medical analysis and diagnosis. In this paper, we introduce an implementation of the anisotropic diffusion which allows reducing the noise and better preserving small structures like vessels in 2D images. A vessel detection filter, based on a multi-scale vesselness function, is then applied to enhance vascular structures.

  20. Investigation of source-detector separation optimization for an implantable perfusion and oxygenation sensor for liver blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Justin S [ORNL; Akl, Tony [Texas A& M University; Cote, Gerard L. [Texas A& M University; Wilson, Mark A. [University of Pittsburgh School of Medicine, Pittsburgh PA; Ericson, Milton Nance [ORNL

    2011-01-01

    An implanted system is being developed to monitor transplanted liver health during the critical 7-10 day period posttransplantation. The unit will monitor organ perfusion and oxygen consumption using optically-based probes placed on both the inflow and outflow blood vessels, and on the liver parenchymal surface. Sensing probes are based on a 3- wavelength LED source and a photodiode detector. Sample diffuse reflectance is measured at 735, 805, and 940 nm. To ascertain optimal source-to-photodetector spacing for perfusion measurement in blood vessels, an ex vivo study was conducted. In this work, a dye mixture simulating 80% blood oxygen saturation was developed and perfused through excised porcine arteries while collecting data for various preset probe source-to-photodetector spacings. The results from this study demonstrate a decrease in the optical signal with decreasing LED drive current and a reduction in perfusion index signal with increasing probe spacing. They also reveal a 2- to 4-mm optimal range for blood vessel perfusion probe source-to-photodetector spacing that allows for sufficient perfusion signal modulation depth with maximized signal to noise ratio (SNR). These findings are currently being applied to guide electronic configuration and probe placement for in vivo liver perfusion porcine model studies.

  1. Analysis by NASA's VESGEN Software of Retinal Blood Vessels Before and After 70-Day Bed Rest: A Retrospective Study

    Science.gov (United States)

    Raghunandan, Sneha; Vyas, Ruchi J.; Vizzeri, Gianmarco; Taibbi, Giovanni; Zanello, Susana B.; Ploutz-Snyder, Robert; Parsons-Wingerter, Patricia A.

    2016-01-01

    Significant risks for visual impairment associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. Impairments include decreased near visual acuity, posterior globe flattening, choroidal folds, optic disc edema and cotton wool spots. We hypothesize that microgravity-induced fluid shifts result in pathological changes within the retinal blood vessels that precede development of visual and other ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated by NASAs innovative VESsel GENeration Analysis (VESGEN) software for two studies: (1) head-down tilt in human subjects before and after 70 days of bed rest, and (2) U.S. crew members before and after ISS missions. VESGEN analysis in previous research supported by the US National Institutes of Health identified surprising new opportunities to regenerate retinal vessels during early-stage, potentially reversible progression of the visually impairing and blinding disease, diabetic retinopathy.

  2. Optofluidic Sensor for Inline Hemolysis Detection on Whole Blood

    DEFF Research Database (Denmark)

    Zhou, Chen; Keshavarz Hedayati, Mehdi; Zhu, Xiaolong

    2018-01-01

    Hemolysis is the rupture of red blood cells and constitutes the most common reason for unsuitable blood samples in the clinic. To detect hemolysis, one has to separate the hemoglobin in blood plasma from that in red blood cells. However, current methods entail centrifugation for cell......-time inline detection on whole blood without extra sample preparation like centrifugation. Long-term testing with inline integration in a modified, commercial blood gas analyzer shows high reliability and repeatability of the measurements even with the presence of interference from bilirubin. We envision...... that the present work has large potential in improving diagnosis quality by enabling PoC hemolysis detection in blood gas analyzers and can also lend unique sensing capabilities to other applications dealing with complex turbid media....

  3. Detecting autologous blood transfusions: a comparison of three passport approaches and four blood markers

    DEFF Research Database (Denmark)

    Mørkeberg, J; Sharpe, K; Belhage, B

    2011-01-01

    Blood passport has been suggested as an indirect tool to detect various kinds of blood manipulations. Autologous blood transfusions are currently undetectable, and the objective of this study was to examine the sensitivities of different blood markers and blood passport approaches in order...... to determine the best approach to detect autologous blood transfusions. Twenty-nine subjects were transfused with either one (n=8) or three (n=21) bags of autologous blood. Hemoglobin concentration ([Hb]), percentage of reticulocytes (%ret) and hemoglobin mass (Hbmass) were measured 1 day before reinfusion...... and six times after reinfusion. The sensitivity and specificity of a novel marker, Hbmr (based on Hbmass and %ret), was evaluated together with [Hb], Hbmass and OFF-hr by different passport methods. Our novel Hbmr marker showed superior sensitivity in detecting the highest dosage of transfused blood...

  4. Cannulation and continuous cross-sectional area measurement of small blood vessels

    NARCIS (Netherlands)

    VanBavel, E.; Mooij, T.; Giezeman, M. J.; Spaan, J. A.

    1990-01-01

    Techniques have been developed for the study of isolated small arteries. To pressurize and perfuse segments of these vessels, a cannula with a low resistance to flow was developed. This cannula consisted of two concentric micropipettes. The end of a vessel segment was sucked into the inner pipette

  5. Mapping by VESGEN of Blood Vessels in the Retinas of ISS Crew Members and Bed Rest Subjects for Increased Understanding of VIIP

    Science.gov (United States)

    Parsons-Wingerter, P. A.; Vizzeri, G.; Tabbi, G.; Zanello, S. B.; Ploutz-Snyder, R.

    2014-01-01

    Research by NASA has established that significant risks for visual impairment in association with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. Impairments include decreased near visual acuity, posterior globe flattening, choroidal folds, optic disc edema, and cotton wool spots. Much remains to be learned about the etiology of VIIP before effective countermeasures can be developed. Contributions of retinal vascular remodeling to the etiology of VIIP have not yet been investigated, primarily due to the current lack of ophthalmic tools for precisely measuring progressive pathophysiological remodeling of the retinal microvasculature. Although ophthalmic science and clinical practice are now highly sophisticated at detecting indirect, secondary signs of vascular remodeling such as cotton wool spots that arise during the progression of retinal vascular diseases, methods for quantifying direct, primary vascular changes are not yet established. To help develop insightful analysis of retinal vascular remodeling for aerospace medicine, we will map and quantify by our innovative VESsel GENeration Analysis (VESGEN) software the remodeling status of retinal blood vessels in crew members before and after ISS missions, and in healthy human subjects before and after head-down tilt bed rest. For this proof-of-concept study, we hypothesize that pathophysiological remodeling of retinal blood vessels occurs in coordination with microgravity-induced fluid shifts prior to development of visual impairments. VESGEN analysis in previous research supported by the US National Institutes of Health identified surprising new opportunities to regenerate retinal vessels during early-stage progression of the visually impairing, potentially blinding disease, diabetic retinopathy.

  6. Processing of MRI images weighted in TOF for blood vessels analysis: 3-D reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez D, J.; Cordova F, T. [Universidad de Guanajuato, Campus Leon, Departamento de Ingenieria Fisica, Loma del Bosque No. 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Cruz A, I., E-mail: hernandezdj.gto@gmail.com [CONACYT, Centro de Investigacion en Matematicas, A. C., Jalisco s/n, Col. Valenciana, 36000 Guanajuato, Gto. (Mexico)

    2015-10-15

    This paper presents a novel presents an approach based on differences of intensities for the identification of vascular structures in medical images from MRI studies of type time of flight method (TOF). The plating method hypothesis gave high intensities belonging to the vascular system image type TOF can be segmented by thresholding of the histogram. The enhanced vascular structures is performed using the filter Vesselness, upon completion of a decision based on fuzzy thresholding minimizes error in the selection of vascular structures. It will give a brief introduction to the vascular system problems and how the images have helped diagnosis, is summarized the physical history of the different imaging modalities and the evolution of digital images with computers. Segmentation and 3-D reconstruction became image type time of flight; these images are typically used in medical diagnosis of cerebrovascular diseases. The proposed method has less error in segmentation and reconstruction of volumes related to the vascular system, clear images and less noise compared with edge detection methods. (Author)

  7. Application of Texture Analysis to Study Small Vessel Disease and Blood-Brain Barrier Integrity.

    Science.gov (United States)

    Valdés Hernández, Maria Del C; González-Castro, Victor; Chappell, Francesca M; Sakka, Eleni; Makin, Stephen; Armitage, Paul A; Nailon, William H; Wardlaw, Joanna M

    2017-01-01

    We evaluate the alternative use of texture analysis for evaluating the role of blood-brain barrier (BBB) in small vessel disease (SVD). We used brain magnetic resonance imaging from 204 stroke patients, acquired before and 20 min after intravenous gadolinium administration. We segmented tissues, white matter hyperintensities (WMH) and applied validated visual scores. We measured textural features in all tissues pre- and post-contrast and used ANCOVA to evaluate the effect of SVD indicators on the pre-/post-contrast change, Kruskal-Wallis for significance between patient groups and linear mixed models for pre-/post-contrast variations in cerebrospinal fluid (CSF) with Fazekas scores. Textural "homogeneity" increase in normal tissues with higher presence of SVD indicators was consistently more overt than in abnormal tissues. Textural "homogeneity" increased with age, basal ganglia perivascular spaces scores ( p  < 0.01) and SVD scores ( p  < 0.05) and was significantly higher in hypertensive patients ( p  < 0.002) and lacunar stroke ( p  = 0.04). Hypertension (74% patients), WMH load (median = 1.5 ± 1.6% of intracranial volume), and age (mean = 65.6 years, SD = 11.3) predicted the pre/post-contrast change in normal white matter, WMH, and index stroke lesion. CSF signal increased with increasing SVD post-contrast. A consistent general pattern of increasing textural "homogeneity" with increasing SVD and post-contrast change in CSF with increasing WMH suggest that texture analysis may be useful for the study of BBB integrity.

  8. Development and evaluation of in vivo tissue engineered blood vessels in a porcine model.

    Science.gov (United States)

    Rothuizen, Tonia C; Damanik, Febriyani F R; Lavrijsen, Tom; Visser, Michel J T; Hamming, Jaap F; Lalai, Reshma A; Duijs, Jacques M G J; van Zonneveld, Anton Jan; Hoefer, Imo E; van Blitterswijk, Clemens A; Rabelink, T J; Moroni, Lorenzo; Rotmans, Joris I

    2016-01-01

    There's a large clinical need for novel vascular grafts. Tissue engineered blood vessels (TEBVs) have great potential to improve the outcome of vascular grafting procedures. Here, we present a novel approach to generate autologous TEBV in vivo. Polymer rods were engineered and implanted, evoking an inflammatory response that culminates in encapsulation by a fibrocellular capsule. We hypothesized that, after extrusion of the rod, the fibrocellular capsule differentiates into an adequate vascular conduit once grafted into the vasculature. Rods were implanted subcutaneously in pigs. After 4 weeks, rods with tissue capsules grown around it were harvested. Tissue capsules were grafted bilaterally as carotid artery interposition. One and 4-week patency were evaluated by angiography whereupon pigs were sacrificed. Tissue capsules before and after grafting were evaluated on tissue remodeling using immunohistochemistry, RNA profiling and mechanical testing. Rods were encapsulated by thick, well-vascularized tissue capsules, composed of circumferentially aligned fibroblasts, collagen and few leukocytes, with adequate mechanical strength. Patency was 100% after 1 week and 87.5% after 4 weeks. After grafting, tissue capsules remodeled towards a vascular phenotype. Gene profiles of TEBVs gained more similarity with carotid artery. Wall thickness and αSMA-positive area significantly increased. Interestingly, a substantial portion of (myo)fibroblasts present before grafting expressed smooth muscle cell markers. While leukocytes were hardly present anymore, the lumen was largely covered with endothelial cells. Burst pressure remained stable after grafting. Autologous TEBVs were created in vivo with sufficient mechanical strength enabling vascular grafting. Grafts differentiated towards a vascular phenotype upon grafting. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. BLOOD VESSELS IN GANGLIA IN HUMAN ESOPHAGUS MIGHT EXPLAIN THE HIGHER FREQUENCY OF MEGAESOPHAGUS COMPARED WITH MEGACOLON

    Directory of Open Access Journals (Sweden)

    Sheila Jorge Adad

    2014-12-01

    Full Text Available This study aimed to determine the existence of blood vessels within ganglia of the myenteric plexus of the human esophagus and colon. At necropsy, 15 stillborns, newborns and children up to two years of age, with no gastrointestinal disorders, were examined. Rings of the esophagus and colon were analyzed and then fixed in formalin and processed for paraffin. Histological sections were stained by hematoxylin-eosin, Giemsa and immunohistochemistry for the characterization of endothelial cells, using antibodies for anti-factor VIII and CD31. Blood vessels were identified within the ganglia of the myenteric plexus of the esophagus, and no blood vessels were found in any ganglia of the colon. It was concluded that the ganglia of the myenteric plexus of the esophagus are vascularized, while the ganglia of the colon are avascular. Vascularization within the esophageal ganglia could facilitate the entrance of infectious agents, as well as the development of inflammatory responses (ganglionitis and denervation, as found in Chagas disease and idiopathic achalasia. This could explain the higher frequency of megaesophagus compared with megacolon.

  10. About a mechanism of the influence of shear stress for viscosity of the blood in vessels of small diameter

    Directory of Open Access Journals (Sweden)

    Лев Николаевич Катюхин

    2014-12-01

    Full Text Available It is proposed a physiological and experimentally confirmed explanation of Fåhraeus-Lindqvist-effect in capillaries using the profile analyses of osmotic deformability of red blood cells. It was shown the dose-dependent change of the erythrocytes deformability in the stage of isotropic spheres after forming artificial water pores (nystatin and occlusion (PbCl2 of available pores. The Sigma-effect reducing of hematocrit and viscosity in a shear flow of blood through the vessels of a small diameter was conditioned by the interchange of liquid phase between the erythrocyte and the plasma.

  11. Thermography for detection of scaling in slurry lines and process vessels

    International Nuclear Information System (INIS)

    Capolingua, Adam; Petrik, Andrew

    2006-01-01

    A major problem in many of today's refineries and mineral processing plants is internal scale build-up within slurry lines and process vessels. Consequences of such an internal scale build-up within lines and vessels include machinery damage, flow restrictions, blockages and localised pipe wear. These problems lead to a loss of production, increased maintenance costs, impinge on worker safety, increase environmental hazards and inevitably reduces profit for the organisation of concern. Hence, the application of an efficient and accurate non-intrusive detection method for locating internal scale within kilometres of lines and numerous process vessels is imperative to reduce maintenance costs and limit production losses. Thermography has been found to be a very useful NDT technique for applications where there is a differential between the ambient and internal product temperatures. The 'insulating' effect of the internal scaling results in a reduced external temperature over the associated area. These temperature differentials can be efficiently detected via a thermographic scan. While this technique is relatively straightforward, the interpretation of the thermographic images usually requires reasonable skill and experience to assess the true extent of each problem detected. In some cases, the true location and extent of scaling within the slurry lines may not be thermally obvious due to the nature of the internal scaling. In such cases, the use of other complementary methods to effectively 'listen'in to the lines has proved to be a valuable procedure. In particular a technology that is typically used in vibration monitoring to assess bearing and gear degradation has been successfully applied in conjunction with thermography to assess lines with localised or dislodged scale. This paper presents a number of case studies where thermography was either applied independently or in conjunction with other measurement techniques, to detect and assess different internal

  12. A microfluidic approach for hemoglobin detection in whole blood

    Science.gov (United States)

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  13. Pressure controlled clamp using shape memory alloy for minimal vessel invasion in blood flow occlusion.

    Science.gov (United States)

    Zhang, Ye; Kanetaka, Hiroyasu; Sano, Yuya; Kano, Mitsuhiro; Kudo, Tadaaki; Sato, Takumi; Shimizu, Yoshinaka

    2013-01-01

    Vessel damage after clamping may affect the success of surgical operations. A new pressure controlled clamp (SMA clamp) was designed using super elastic property of shape memory alloy (SMA) to realize atraumatic vessel occlusion. The ability and biological effect of the SMA clamp to control pressure was investigated in vivo. The loading-displacement curves of the SMA clamps (experimental group) and conventional clamp (control group) by occlusion of pig carotid arteries were evaluated using a clamping-pressure analyzing system. To investigate macroscopically and histologically the vessel damage of the SMA and conventional clamps, pig carotid arteries were stained with Evan's blue and its histological sections were stained with Elastica Massion after clamping for fifteen minutes. Constant value was shown in the loading-displacement curve of SMA clamp. In the control group, damaged area stained with Evan's blue in the vessel wall showed enlargement with the pressure increasing. Less areas in experimental groups are observed than that in the control group. Histological section in the experimental group showed no obvious except a slight compressive damage in the tunica intima. In the control group, vessel wall showed irreversible damages. This experiment indicated that the SMA clamp, which has a unique mechanical property, can be used without vessels damage. This pressure controlled clamp can be a selection in clinical apparatus to improve surgical safety.

  14. Impact of segmentation errors and retinal blood vessels on retinal nerve fibre layer measurements using spectral-domain optical coherence tomography.

    Science.gov (United States)

    Ye, Cong; Yu, Marco; Leung, Christopher Kai-Shun

    2016-05-01

    To investigate the impact of retinal blood vessels and retinal nerve fibre layer (RNFL) segmentation errors on RNFL measurement. One eye of 180 subjects (60 normal, 66 mild-to-moderate and 54 advanced glaucoma subjects) was randomly selected for RNFL imaging with a spectral-domain OCT. The boundaries of the RNFL detected by the instrument software were checked, and the segmentation errors were corrected by a customized computer program. The differences in average and regional RNFL thicknesses (RNFLT) before and after the correction were analysed to determine the frequency of segmentation error (defined as an absolute difference in average RNFLT >5.0 μm). The ratio of retinal blood vessel cross-sectional area to RNFL cross-sectional area was calculated. The difference in average RNFLT (postsegmentation minus presegmentation refinement) ranged from -3.0 to 2.5 μm (mean ± standard deviation: 0.83 ± 0.86 μm) in the normal, -2.5 to 5.0 μm (0.56 ± 1.08 μm) in the mild-to-moderate glaucoma and -11.0 to 9.5 μm (0.05 ± 3.49 μm) in the advanced glaucoma groups (p = 0.003). A total of 15% of eyes had average RNFLT measurement error >5.0 μm in the advanced glaucoma group. The proportion of retinal blood vessels in the RNFL also increased with the severity of glaucoma (p < 0.001) with 4.2 ± 1.0% in the normal group, 4.9 ± 1.5% in the mild-to-moderate and 8.5 ± 3.5% in the advanced glaucoma groups. Inclusion of retinal blood vessels and RNFL segmentation error could adversely affect RNFL measurement, particularly in advanced glaucoma when the RNFL was thin. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. Evaluation of Mast Cell and Blood Vessel Density in Inflammatory Periapical Lesions

    Directory of Open Access Journals (Sweden)

    Safoura Seifi

    2012-01-01

    Full Text Available Introduction: Radicular cystsand periapical granulomas are the most common periapical inflammatory lesions. However, the role of cellular immunity and microvessels in their pathogenesis remains unknown. The aim of this study was to evaluate the mast cell density (MCD, mircovessel density (MVD and investigating the correlation between their densities with each other in the above mentioned lesions.Materials & Methods: In this descriptive cross-sectional study, 40 paraffin blocks of mentioned lesions were selected from achieves of School of Dentistry, Babol University of Medical Sciences. Three sections were prepared from each block and stained by hematoxylin-eosin, toluidine blue, and immunohistochemically for CD34 to determine the score of inflammation, presence of mast cells and degranulatedmast cells (DMCs, and MVD, respectively. The correlation between MCD and either inflammatory infiltrate or MVD was evaluated. Data analyzed by t student, Mann-Whitney and Spearman test.Results: Mast cells were present in all periapical inflammatory lesions; 15.4±14.8 for MCD, 7.2±6.1 for DMCs, and the ratio of DMCs to total number of MCs was 0.354±0.166 and 14.8+4.44 for blood vessel density in radicular cyst and 8.52±6.75, 2.91±2.1, 0.196±0.194 and 13±8.02 in periapical granulomas, respectively. There was a positive correlation between MCD and MVD in radicular cyst (P=0.03, r=0.341, but not in periapical granulomas (P=0.6, r=0.124. MCD and MVD increased with the score of inflammation in radicular cyst (P=0.001, r=0.7 and periapical granuloma (P=0.012, r=0.54.Conclusion: Mast cells and microvessels play a role in pathogenesis of periapical inflammatory lesions. In this study, the density of mast cells and DMCs in radicular cyst was higher than periapical granulomas, but no difference was observed regarding MVD in periapical inflammatory lesions. It seems that the relationship between MCD and MVD is different based on the clinical stage of periapical

  16. 3-D MDT with spherical targets by bilinear interpolation for determining blood velocity profiles including the vessel wall effect

    Science.gov (United States)

    Choomphon-anomakhun, Natthaphon; Natenapit, Mayuree

    2018-02-01

    A numerical simulation of three-dimensional (3-D) implant assisted-magnetic drug targeting (IA-MDT) using ferromagnetic spherical targets, including the effect from the vessel wall on the blood flow, is presented. The targets were implanted within arterioles and subjected to an externally uniform applied magnetic field in order to increase the effectiveness of targeting magnetic drug carrier particles (MDCPs). The capture area (As) of the MDCPs was determined by inspection of the particle trajectories simulated from the particle equations of motion. The blood flow velocities at any particle position around the target were obtained by applying bilinear interpolation to the numerical blood velocity data. The effects on As of the type of ferromagnetic materials in the targets and MDCPs, average blood flow rates, mass fraction of the ferromagnetic material in the MDCPs, average radii of MDCPs (Rp) and the externally applied magnetic field strength (μ0H0) were evaluated. Furthermore, the appropriate μ0H0 and Rp for the IA-MDT design is suggested. In the case of the SS409 target and magnetite MDCPs, dimensionless capture areas ranging from 4.1- to 12.4 and corresponding to particle capture efficiencies of 31-94% were obtained with Rp ranging from 100- to 500 nm, weight fraction of 80%, μ0H0 of 0.6 T and an average blood flow rate of 0.01 ms-1. In addition, the more general 3-D modelling of IA-MDT in this work is applicable to IA-MDT using spherical targets implanted within blood vessels for both laminar and potential blood flows including the wall effect.

  17. Computer-aided detection of pulmonary embolism: Influence on radiologists' detection performance with respect to vessel segments

    International Nuclear Information System (INIS)

    Das, Marco; Muehlenbruch, Georg; Helm, Anita; Guenther, Rolf W.; Wildberger, Joachim E.; Bakai, Annemarie; Salganicoff, Marcos; Liang, Jianming; Wolf, Matthias; Stanzel, Sven

    2008-01-01

    The purpose was to assess the sensitivity of a CAD software prototype for the detection of pulmonary embolism in MDCT chest examinations with regard to vessel level and to assess the influence on radiologists' detection performance. Forty-three patients with suspected PE were included in this retrospective study. MDCT chest examinations with a standard PE protocol were acquired at a 16-slice MDCT. All patient data were read by three radiologists (R1, R2, R3), and all thrombi were marked. A CAD prototype software was applied to all datasets, and each finding of the software was analyzed with regard to vessel level. The standard of reference was assessed in a consensus read. Sensitivity for the radiologists and CAD software was assessed. Thirty-three patients were positive for PE, with a total of 215 thrombi. The mean overall sensitivity for the CAD software alone was 83% (specificity, 80%). Radiologist sensitivity was 77% = R3, 82% = R2, and R1 = 87%. With the aid of the CAD software, sensitivities increased to 98% (R1), 93% (R2), and 92% (R3) (p<0.0001). CAD performance at the lobar level was 87%, at the segmental 90% and at the subsegmental 77%. With the use of CAD for PE, the detection performance of radiologists can be improved. (orig.)

  18. Ultrastructure of Pericystic or Intracystic Blood Vessels in Epidermoid Cysts-A Transmission Electron Microscopy Study: Laboratory Investigation.

    Science.gov (United States)

    Ren, Xiao-Hui; Ma, Jun; Zeng, Chun; Sun, Yi-Lin; Lin, Song

    2017-07-01

    Recently, we reported a tendency toward spontaneous hemorrhage in both the preoperative and postoperative periods in patients with intracranial epidermoid cyst (EC). According to our experience, this tendency for spontaneous hemorrhage was partly caused by the pathologic blood vessels adjacent to the EC. This study was designed to testify this hypothesis. Twenty-three removable pericystic or intracystic blood vessels from 17 patients with EC were collected during surgery and were then examined by transmission electron microscopy. The microvascular structure in gliomas was chosen as the control. Under electron microscopy, variant pathologic changes of vessels were found in all patients with EC. In the tunicae intima, we found vacuolization, apoptosis, necrosis, and intralumenal protrusion of endothelial cells, as well as swollen basement and highly flexed and discontinued elastic plate. In the tunicae media, vacuolization and swollen mitochondria were found in muscular cells. In the tunicae adventitia, extravascular erythrocytes, edema or apoptosis of pericytes, collagen predominance, and inflammatory cell infiltration and destruction were found. Neuron denature and necrosis were found in the peripheral brain tissue. In the microvascular structure of 5 glioma specimens, we found enlargement and hyperplasia of endothelial cells, swollen basement membrane, swollen pericytes, and astrocytic hyperplasia and neuron denature in adjacent brain tissues. Our findings provide strong evidence for the hypothesis that intracystic or pericystic vascular degeneration or destruction accounts for the spontaneous hemorrhage tendency before and after surgical resection of ECs. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Subsurface thermal behaviour of tissue mimics embedded with large blood vessels during plasmonic photo-thermal therapy.

    Science.gov (United States)

    Paul, Anup; Narasimhan, Arunn; Das, Sarit K; Sengupta, Soujit; Pradeep, Thalappil

    2016-11-01

    The purpose of this study was to understand the subsurface thermal behaviour of a tissue phantom embedded with large blood vessels (LBVs) when exposed to near-infrared (NIR) radiation. The effect of the addition of nanoparticles to irradiated tissue on the thermal sink behaviour of LBVs was also studied. Experiments were performed on a tissue phantom embedded with a simulated blood vessel of 2.2 mm outer diameter (OD)/1.6 mm inner diameter (ID) with a blood flow rate of 10 mL/min. Type I collagen from bovine tendon and agar gel were used as tissue. Two different nanoparticles, gold mesoflowers (AuMS) and graphene nanostructures, were synthesised and characterised. Energy equations incorporating a laser source term based on multiple scattering theories were solved using finite element-based commercial software. The rise in temperature upon NIR irradiation was seen to vary according to the position of the blood vessel and presence of nanoparticles. While the maximum rise in temperature was about 10 °C for bare tissue, it was 19 °C for tissue embedded with gold nanostructures and 38 °C for graphene-embedded tissues. The axial temperature distribution predicted by computational simulation matched the experimental observations. A different subsurface temperature distribution has been obtained for different tissue vascular network models. The position of LBVs must be known in order to achieve optimal tissue necrosis. The simulation described here helps in predicting subsurface temperature distributions within tissues during plasmonic photo-thermal therapy so that the risks of damage and complications associated with in vivo experiments and therapy may be avoided.

  20. A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI ☆

    OpenAIRE

    Okell, Thomas W.; Chappell, Michael A.; Jezzard, Peter

    2013-01-01

    Angiographic methods can provide valuable information on vessel morphology and hemodynamics, but are often qualitative in nature, somewhat limiting their ability for comparison across arteries and subjects. In this work we present a method for quantifying absolute blood volume flow rates within large vessels using dynamic angiographic data. First, a kinetic model incorporating relative blood volume, bolus dispersion and signal attenuation is fitted to the data. A self-calibration method is al...

  1. Ultrasensitive Detection of Shigella Species in Blood and Stool.

    Science.gov (United States)

    Luo, Jieling; Wang, Jiapeng; Mathew, Anup S; Yau, Siu-Tung

    2016-02-16

    A modified immunosensing system with voltage-controlled signal amplification was used to detect Shigella in stool and blood matrixes at the single-digit CFU level. Inactivated Shigella was spiked in these matrixes and detected directly. The detection was completed in 78 min. Detection limits of 21 CFU/mL and 18 CFU/mL were achieved in stool and blood, respectively, corresponding to 2-7 CFUs immobilized on the detecting electrode. The outcome of the detection of extremely low bacterium concentration, i.e., below 100 CFU/mL, blood samples show a random nature. An analysis of the detection probabilities indicates the correlation between the sample volume and the success of detection and suggests that sample volume is critical for ultrasensitive detection of bacteria. The calculated detection limit is qualitatively in agreement with the empirically determined detection limit. The demonstrated ultrasensitive detection of Shigella on the single-digit CFU level suggests the feasibility of the direct detection of the bacterium in the samples without performing a culture.

  2. Dissociation between vascular endothelial growth factor receptor-2 and blood vessel density in the caudate nucleus after chronic hydrocephalus.

    Science.gov (United States)

    Deshpande, Abhishek; Dombrowski, Stephen M; Leichliter, Anna; Krajcir, Natalie; Zingales, Nicholas; Inoue, Masahiro; Schenk, Soren; Fukamachi, Kiyotaka; Luciano, Mark G

    2009-11-01

    Chronic hydrocephalus (CH) is characterized by the presence of ventricular enlargement, decreased cerebral blood flow (CBF), and brain tissue oxygen delivery. Although the underlying pathophysiological role of vascular endothelial growth factor (VEGF) is not clear, ischemic-hypoxic events in CH are known to trigger its release. Previously, we have shown increased VEGF receptor-2 (VEGFR-2) and blood vessel density (BVd) in the hippocampus after CH. We investigated changes in neuronal and glial VEGFR-2 density and BVd in the caudate nucleus in an experimental model of CH. Animals with CH were divided into short term (ST, 2 to 4 weeks) and long term (LT, 12 to 16 weeks) and were compared with surgical controls (SCs, 12 to 16 weeks). The cellular and BVds were estimated using immunohistochemical and stereological counting methods. Overall, percentage (%)VEGFR-2 neurons were approximately two times greater in CH (ST, LT) than in SC. By comparison, glial cell %VEGFR-2 was greater by 10% to 17% in ST and 4% to 11% lower in LT compared with that in SC. Blood vessel density was significantly lower in CH than in SC in the superficial caudate. Changes in cerebrospinal fluid ventricular volume and pressure, as well as in CBF did not correlate with either VEGFR-2 or BVd. These observed findings suggest that destructive forces may outweigh angiogenic forces and possibly show a disassociation between VEGFR-2 and BV expressions.

  3. Study of blood flow inside the stenosis vessel under the effect of solenoid magnetic field using ferrohydrodynamics principles

    Science.gov (United States)

    Badfar, Homayoun; Motlagh, Saber Yekani; Sharifi, Abbas

    2017-10-01

    In this paper, biomagnetic blood flow in the stenosis vessel under the effect of the solenoid magnetic field is studied using the ferrohydrodynamics (FHD) model. The parabolic profile is considered at an inlet of the axisymmetric stenosis vessel. Blood is modeled as electrically non-conducting, Newtonian and homogeneous fluid. Finite volume and the SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm are utilized to discretize governing equations. The investigation is studied at different magnetic numbers ( MnF=164, 328, 1640 and 3280) and the number of the coil loops (three, five and nine loops). Results indicate an increase in heat transfer, wall shear stress and energy loss (pressure drop) with an increment in the magnetic number (ratio of Kelvin force to dynamic pressure force), arising from the FHD, and the number of solenoid loops. Furthermore, the flow pattern is affected by the magnetic field, and the temperature of blood can be decreased up to 1.48 {}°C under the effect of the solenoid magnetic field with nine loops and reference magnetic field ( B0) of 2 tesla.

  4. Blood Vessel Model using Tissue Modules with on-demand Stimuli

    NARCIS (Netherlands)

    Trikalitis, V.; Salehi Nik, N.; Rouwkema, J.

    2017-01-01

    Artificial vascularization of tissue has been a major barrier in the upscaling of tissue engineering. Achieving angiogenesis from a pre-existing vessel in a controlled manner is a possible solution to prevascularize tissue. Microfluidic approaches do not allow yet the creation of a complex

  5. A new approach in the numerical simulation for the blood flow in large vessels

    Directory of Open Access Journals (Sweden)

    Balazs ALBERT

    2013-03-01

    Full Text Available In this paper we are proposing a new approach in the numerical simulation of the bloodflow in large vessels. The initial conditions are set to be compatible with the non-Newtonian modelused. Numerical experiments in stenosed artery and in artery with aneurysm (using COMSOL 3.3,are presented.

  6. Blood vessel endothelium-directed tumor cell streaming in breast tumors requires the HGF/C-Met signaling pathway.

    Science.gov (United States)

    Leung, E; Xue, A; Wang, Y; Rougerie, P; Sharma, V P; Eddy, R; Cox, D; Condeelis, J

    2017-05-11

    During metastasis to distant sites, tumor cells migrate to blood vessels. In vivo, breast tumor cells utilize a specialized mode of migration known as streaming, where a linear assembly of tumor cells migrate directionally towards blood vessels on fibronectin-collagen I-containing extracellular matrix (ECM) fibers in response to chemotactic signals. We have successfully reconstructed tumor cell streaming in vitro by co-plating tumors cells, macrophages and endothelial cells on 2.5 μm thick ECM-coated micro-patterned substrates. We found that tumor cells and macrophages, when plated together on the micro-patterned substrates, do not demonstrate sustained directional migration in only one direction (sustained directionality) but show random bi-directional walking. Sustained directionality of tumor cells as seen in vivo was established in vitro when beads coated with human umbilical vein endothelial cells were placed at one end of the micro-patterned 'ECM fibers' within the assay. We demonstrated that these endothelial cells supply the hepatocyte growth factor (HGF) required for the chemotactic gradient responsible for sustained directionality. Using this in vitro reconstituted streaming system, we found that directional streaming is dependent on, and most effectively blocked, by inhibiting the HGF/C-Met signaling pathway between endothelial cells and tumor cells. Key observations made with the in vitro reconstituted system implicating C-Met signaling were confirmed in vivo in mammary tumors using the in vivo invasion assay and intravital multiphoton imaging of tumor cell streaming. These results establish HGF/C-Met as a central organizing signal in blood vessel-directed tumor cell migration in vivo and highlight a promising role for C-Met inhibitors in blocking tumor cell streaming and metastasis in vivo, and for use in human trials.

  7. Morphological evaluation of the cerebral blood vessels in the late gestation fetal sheep following hypoxia in utero.

    Science.gov (United States)

    Baburamani, Ana A; Lo, Camden; Castillo-Melendez, Margie; Walker, David W

    2013-01-01

    Hypoxia can significantly contribute to the development of permanent brain injury in the term neonate; however the response of cerebral blood vessels is not well understood. This study aimed to quantitatively measure vascular density and morphology using laminin immunohistochemistry as a marker of blood vessels, and determine the effects of a single, severe bout of hypoxia (umbilical cord occlusion, UCO) late in gestation on the developing cerebrovasculature in fetal sheep. At 124-126 days gestation singleton fetal sheep underwent surgery for implantation of catheters and placement of an inflatable cuff around the umbilical cord. A 10 min UCO or sham UCO (n=5) occurred at 132 days gestation. Fetal brains were collected at 24 h (n=5) or 48 h (n=4) after UCO for vascular density and morphology analysis of laminin immunohistochemistry. 48 h following a single, brief bout of severe hypoxia late in gestation decreased vascular density was seen in the caudate nucleus and no changes in vascular morphology occurred. However closer analysis revealed a significant shift in the frequency of smaller (≤10 μm) to larger (≤100 μm) perimeter blood vessels in periventricular and subcortical white matter. Close examination of the frequency distribution of vascular perimeter highlights that alterations in vascular morphology persist in the near term fetal brain for up to 48 h following a brief (10 min) hypoxia in white but not gray matter. These findings suggest that the near term brain may still be vulnerable to white matter injury following in utero hypoxia. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Effect of antiprogesterone RU486 on VEGF expression and blood vessel remodeling on ovarian follicles before ovulation.

    Directory of Open Access Journals (Sweden)

    Annunziata Mauro

    Full Text Available BACKGROUND: The success of ovarian follicle growth and ovulation is strictly related to the development of an adequate blood vessel network required to sustain the proliferative and endocrine functions of the follicular cells. Even if the Vascular Endothelial Growth Factor (VEGF drives angiogenesis before ovulation, the local role exerted by Progesterone (P₄ remains to be clarified, in particular when its concentration rapidly increases before ovulation. AIM: This in vivo study was designed to clarify the effect promoted by a P₄ receptor antagonist, RU486, on VEGF expression and follicular angiogenesis before ovulation, in particular, during the transition from pre to periovulatory follicles induced by human Chorionic Gonadotropins (hCG administration. MATERIAL AND METHODS: Preovulatory follicle growth and ovulation were pharmacologically induced in prepubertal gilts by combining equine Chorionic Gonadotropins (eCG and hCG used in the presence or absence of RU486. The effects on VEGF expression were analyzed using biochemical and immunohistochemical studies, either on granulosa or on theca layers of follicles isolated few hours before ovulation. This angiogenic factor was also correlated to follicular morphology and to blood vessels architecture. RESULTS AND CONCLUSIONS: VEGF production, blood vessel network and follicle remodeling were impaired by RU486 treatment, even if the cause-effect correlation remains to be clarified. The P₄ antagonist strongly down-regulated theca VEGF expression, thus, preventing most of the angiogenic follicle response induced by hCG. RU486-treated follicles displayed a reduced vascular area, a lower rate of endothelial cell proliferation and a reduced recruitment of perivascular mural cells. These data provide important insights on the biological role of RU486 and, indirectly, on steroid hormones during periovulatory follicular phase. In addition, an in vivo model is proposed to evaluate how periovulatory

  9. Micropatterned coculture of vascular endothelial and smooth muscle cells on layered electrospun fibrous mats toward blood vessel engineering.

    Science.gov (United States)

    Li, Huinan; Liu, Yaowen; Lu, Jinfu; Wei, Jiaojun; Li, Xiaohong

    2015-06-01

    A major challenge in vascular engineering is the establishment of proper microenvironment to guide the spatial organization, growth, and extracellular matrix (ECM) productions of cells found in blood vessels. In the current study, micropatterned fibrous mats with distinct ridges and grooves of different width were created to load smooth muscle cells (SMCs), which were assembled by stacking on vascular endothelial cell (EC)-loaded flat fibrous mats to mimic the in vivo-like organized structure of blood vessels. SMCs were mainly distributed in the ridges, and aligned fibers in the patterned regions led to the formation of elongated cell bodies, intense actin filaments, and expressions of collagen I and α-smooth muscle actin in a parallel direction with fibers. ECs spread over the flat fibrous mats and expressed collagen IV and laminin with a cobblestone-like feature. A z-stack scanning of fluorescently stained fibrous mats indicated that SMCs effectively infiltrated into fibrous scaffolds at the depth of around 200 μm. Compared with SMCs cultured alone, the coculture with ECs enhanced the proliferation, infiltration, and cytoskeleton elongation of SMCs on patterned fibrous mats. Although the coculture of SMCs made no significant difference in the EC growth, the coculture system on patterned fibrous scaffolds promoted ECM productions of both ECs and SMCs. Thus, this patterned fibrous configuration not only offers a promising technology in the design of tissue engineering scaffolds to construct blood vessels with durable mechanical properties, but also provides a platform for patterned coculture to investigate cell-matrix and cell-cell interactions in highly organized tissues. © 2014 Wiley Periodicals, Inc.

  10. Development of a fast ultrasonic three-dimensional imaging system for diagnosing blood vessels of artificial-kidney-dialyzed patients

    Science.gov (United States)

    Akahane, Mutsuhiro; Mochizuki, Takashi; Yamashita, Yuko; Kasai, Chihiro; Kobayashi, Masayuki; Kishino, Osamu; Ogawa, Tomoya

    2001-05-01

    It is very important to observe the vessels of the patient who are dialyzed artificially. An X-ray examination using contrast medium injected to the patient has been used for this purpose up to the present, but sometimes the examination has a risk of radiation damage. Therefore, we developed a safe and easy-to-use system in which 3D images of the vessels in the patients are reconstructed very quick from ultrasonic echoes. In this system, a view point for 3D rendering is set on the above position of the ultrasonic transducer, and a ray for the rendering is coincided with an ultrasonic beam. These features enable 3D images to be gradually reconstructed in real time while the echoes are being received. A magnetic position sensor system and a special 3D scanner which was developed were adopted for acquiring 3D echo data. In signal processing, intensity inversion technology is carried out before the 3D rendering process in order to detect and emphasize the vessels. With this system, we have acquired echo signals from the vessels in the arm of kidney dialyzed patients and made similar 3D images of X-ray angiography with the echoes in a short time such as 4 to 8 seconds.

  11. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  12. The evolving science of detection of 'blood doping'

    DEFF Research Database (Denmark)

    Lundby, Carsten; Robach, Paul; Saltin, Bengt

    2012-01-01

    Blood doping practices in sports have been around for at least half a century and will likely remain for several years to come. The main reason for the various forms of blood doping to be common is that they are easy to perform, and the effects on exercise performance are gigantic. Yet another...... reason for blood doping to be a popular illicit practice is that detection is difficult. For autologous blood transfusions, for example, no direct test exists, and the direct testing of misuse with recombinant human erythropoietin (rhEpo) has proven very difficult despite a test exists. Future blood...... and that they work more efficiently with the international sports federations in an attempt to limit blood doping....

  13. MRI measurement of oxygen extraction fraction, mean vessel size and cerebral blood volume using serial hyperoxia and hypercapnia.

    Science.gov (United States)

    Germuska, Michael; Bulte, Daniel P

    2014-05-15

    Functional magnetic resonance imaging measures signal increases arising from a variety of interrelated effects and physiological sources. Recently there has been some success in disentangling this signal in order to quantify baseline physiological parameters, including the resting oxygen extraction fraction (OEF), cerebral blood volume (CBV) and mean vessel size. However, due to the complicated nature of the signal, each of these methods relies on certain physiological assumptions to derive a solution. In this work we present a framework for the simultaneous, voxelwise measurement of these three parameters. The proposed method removes the assumption of a fixed vessel size from the quantification of OEF and CBV, while simultaneously removing the need for an assumed OEF in the calculation of vessel size. The new framework is explored through simulations and validated with a pilot study in healthy volunteers. The MRI protocol uses a combined hyperoxia and hypercapnia paradigm with a modified spin labelling sequence collecting multi-slice gradient echo and spin echo data. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. [Effect on maternal blood dilution of fetoscopic laser occlusion of chorioangiopagous vessels in treating twin to twin transfusion syndrome].

    Science.gov (United States)

    Wang, Xueju; Wei, Yuan; Yuan, Pengbo; Zhao, Yangyu

    2016-01-01

    To evaluate the effect on maternal blood dilution of fetoscopic laser occlusion of chorioangiopagous vessels (FLOC) in treating twin to twin transfusion syndrome (TTTS). The clinical data of 71 cases of TTTS who had FLOC in Peking University Third Hospital were reviewed. Fluid intake, blood pressure, heart rate, red blood cell count, hemoglobin and hematocrit in perioperative 24 hours were analyzed. (1) According to the Quintero staging, 9 cases were stage Ⅰ, 24 were stage Ⅱ, 28 were stage Ⅲ and 10 cases were stage Ⅳ. (2) The average operation time of FLOC was (64.0±16.3) minutes. One case had placental abruption after the procedure; one had placental vessel rupture and 6 women refused to take blood counting. These 8 cases were excluded and 63 cases were included in the study. (3) The perioperative bleeding volume was 3 (1, 5) ml, and the volume of fluid intake, urine, amniotic fluid drainage and net fluid intake in the perioperative 24 hours was 2 050 ml(1 530 ml, 3 700 ml), 2 300 ml (1 100 ml, 3 500 ml), 1 900 ml (1 400 ml, 2 700 ml) and -1 760 ml (-100 ml, -3 350 ml), respectively. There was no significant difference between maternal blood pressure or heart rate preoperatively and postoperatively. (4) The maternal red blood cell count [(3.47±0.36)×10(12)/L versus (3.01± 0.37)×10(12)/L, P=0.000], hemoglobin [(107.8±12.1) g/L versus (95.1±11.2) g/L, P=0.000] and hematocrit [0.313(0.238, 0.387) versus 0.276(0.213, 0.800), P=0.000] decreased significantly 24 hours after FLOC. (5) The postoperative hematocrit decreased more in the group which the amniotic fluid drainage volume was 2 000-3 000 ml than that in the group which the amniotic fluid drainage volume was 1 000-1 999 ml. The blood dilution can not be ignored after the FLOC in TTTS patients. The more the amniodrainage volume during the FLOC, the more the maternal blood dilution would be. It might result from amniodrainage during the FLOC, improved maternal-placenta circulation and tocolytics used

  15. Fast magnetic reconstruction of the portal vein with allogeneic blood vessels in canines.

    Science.gov (United States)

    Wang, Shan-Pei; Yan, Xiao-Peng; Xue, Fei; Dong, Ding-Hui; Zhang, Xu-Feng; Ma, Feng; Wang, Hao-Hua; Lv, Yi

    2015-06-01

    The resection and reconstruction of large vessels, including the portal vein, are frequently needed in tumor resection. Warm ischemia before reconstruction might have deleterious effects on the function of some vital organs and therefore, how to reconstruct the vessels quickly after resection is extremely important. The present study was to introduce a new type of magnetic compression anastomosis (MCA) device to establish a quick non-suture anastomosis of the portal vein after resection in canines. The new MCA device consists of a pair of titanium alloy and neodymium-ferrum-boron magnet (Ti-NdFeB) composite rings. The NdFeB magnetic ring as a core of the device was hermetically sealed inside the biomedical titanium alloy case. Twelve canines were divided into two groups: a MCA group in which the end-to-end anastomoses was made with a new device after resection in the portal vein and a traditional manual suture (TMS) group consisted of 6 canines. The anastomosis time, anastomotic patency and quality were investigated at week 24 postoperatively. The portal vein was reconstructed successfully in all of the animals and they all survived. The duration of portal vein anastomosis was significantly shorter in the MCA group than in the TMS group (8.16+/-1.25 vs 36.24+/-2.17 min, PNdFeB composite MCA device was applicable in reconstruction of large vessels after resection. This device was easy to use and the anastomosis was functionally better than the traditional sutured anastomosis.

  16. Studies of aggregated nanoparticles steering during magnetic-guided drug delivery in the blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Hoshiar, Ali Kafash [School of Mechanical and Aerospace Engineering and ReCAPT, Gyeongsang National University, Jinju 660-701 (Korea, Republic of); Faculty of Industrial and Mechanical Engineering, Islamic Azad University, Qazvin Branch, Qazvin (Iran, Islamic Republic of); Le, Tuan-Anh [School of Mechanical and Aerospace Engineering and ReCAPT, Gyeongsang National University, Jinju 660-701 (Korea, Republic of); Amin, Faiz Ul [Department of Biology and Applied Life Science, Gyeongsang National University, Jinju 660-701 (Korea, Republic of); Kim, Myeong Ok, E-mail: mokim@gnu.ac.kr [Department of Biology and Applied Life Science, Gyeongsang National University, Jinju 660-701 (Korea, Republic of); Yoon, Jungwon, E-mail: jwyoon@gnu.ac.kr [School of Mechanical and Aerospace Engineering and ReCAPT, Gyeongsang National University, Jinju 660-701 (Korea, Republic of)

    2017-04-01

    Magnetic-guided targeted drug delivery (TDD) systems can enhance the treatment of diverse diseases. Despite the potential and promising results of nanoparticles, aggregation prevents precise particle guidance in the vasculature. In this study, we developed a simulation platform to investigate aggregation during steering of nanoparticles using a magnetic field function. The magnetic field function (MFF) comprises a positive and negative pulsed magnetic field generated by electromagnetic coils, which prevents adherence of particles to the vessel wall during magnetic guidance. A commonly used Y-shaped vessel was simulated and the performance of the MFF analyzed; the experimental data were in agreement with the simulation results. Moreover, the effects of various parameters on magnetic guidance were evaluated and the most influential identified. The simulation results presented herein will facilitate more precise guidance of nanoparticles in vivo. - Highlights: • We developed a simulation platform to investigate aggregation of nanoparticles. • The influential parameters for magnetic steering of a Y-shaped vessel were identified. • The proposed platform will facilitate more precise guidance of nanoparticles in vivo.

  17. Correlation between expressions of hypoxia -inducible factor (HIF-1α, blood vessels density, cell proliferation, and apoptosis intensity in canine fibromas and fibrosarcomas

    Directory of Open Access Journals (Sweden)

    Madej Janusz A.

    2014-03-01

    Full Text Available The study aimed to demonstrate the expression of hypoxia-inducible factor (HIF-1α in soft tissue mesenchymal tumours (fibroma and fibrosarcoma in dogs. An attempt was made to correlate the obtained results with density of blood vessels (expression of von Willebrand Factor, vWF, expression of Ki-67 proliferation antigen, and with intensity of apoptosis in studied tumours. The study was performed on paraffin sections of 15 fibromas and 40 fibrosarcomas sampled from 55 female dogs aged 6 to 16 years. Immunohistochemical staining against HIF-1α, vWF, and Ki-67 was performed. Apoptosis was detected with the use of TUNEL reaction. A significantly higher HIF-1α expression was noted in fibrosarcomas in comparison to fibromas (P < 0.0001. HIF-1α expression in fibromas manifested strong positive correlation with tumour vascularity (r = 0.67, P = 0.007. Moreover, HIF-1α expression in fibrosarcomas manifested a moderate positive correlation with tumour malignancy grade (r = 0.44, P = 0.004, tumour vascularity (r = 0.52, P < 0.001, Ki-67 antigen expression (r = 0.42; P = 0.007, and TUNELpositive cells (r = 0.37, P = 0.017. Expression of HIF-1α was detected in 86.7% of fibroma type tumours and in 100% of fibrosarcomas. In all studied tumours expression of HIF-1α manifested positive correlation with the density of blood vessels, and in fibrosarcomas it correlated also with malignancy grade, intensity of Ki-67 expression, and with intensity of apoptosis in tumour cells.

  18. APPLICATION OF MALARIA DETECTION OF DRAWING BLOOD CELLS USING MICROSCOPIC OpenCV

    Directory of Open Access Journals (Sweden)

    Antonius Herusutopo

    2011-10-01

    literature studies about computer division with OpenCV and data collection of microscopic of blood sample. Analysis method includes process, detection procedure and malaria diagnosis. While design method includes steps of detection implementation and diagnosis to the application program, coding and continued with evaluation.MalariaMalaria parasites in human have a life cycle that requires a human host and mosquito host. In the anopheles mosquito, plasmodium does sexual reproduction. In humans, these parasites asexual reproduction, starting in the liver cells (hepatocytes, then repeatedly in the red blood cells (erythrocytes.While an infected female anopheles mosquito is sucking human’s blood, at the same time the mosquito inserts its saliva that is to keep the capillary vessels, which is inhaled not forming a blood clots factor that causes the blood flow stops. At this time the parasite creates sporozoites to enter the blood flow and infect hepatocytes. For one until two weeks (depends on plasmodium species, each sporozoites creates schizont; a structure that contains thousands of merozoites. When schizont is mature, hepatocytes will rupture and release merozoites to blood flow.In plasmodium vivax and plasmodium ovale, sporozoites develops into hipnozoit; a form of plasmodium that in dorman phase during several months to years. When hipnozoit re-activate, they will evolve into schizont that will cause recurrent symptoms to the infected person.Next is the merozoites, which is released to the blood flow, will invade erythrocyte then they will grow and consume hemoglobin. In erythrocyte, half of merozoites will grow to another phase of asexual, which creates schizont filled with merozoites. When schizont is mature, the cell will rupture and merozoites will be released and invade erythrocyte.

  19. PWR neutron ex-vessel detection calculations using three-dimensional codes

    International Nuclear Information System (INIS)

    Dekens, O.; Lefebvre, J.C.; Rohart, M.; Chiron, M.

    1997-01-01

    During the accident of TM12, the signal delivered by source detectors was exceptionally high. This phenomenon was found out to be due to the water inventory in the primary system. Thus, in their research activity, Electricite de France (EdF) and Commissariat a l'Energie Atomique (CEA) have jointly launched a programme, whose aim was to determine to what extent the response of ex-vessel neutron detectors are representative of reactor water level (or sources positions) in a French 900 MWe PWR. In this framework, both partners developed the methods needed for each step of the calculation chain. Finally, a simulation of a LOCA indicates that the loss of coolant can be detected by existing monitoring system, and could be more efficiently found by changing the position of the source range detectors. (authors)

  20. Vessel Wall Enhancement and Blood-Cerebrospinal Fluid Barrier Disruption After Mechanical Thrombectomy in Acute Ischemic Stroke.

    Science.gov (United States)

    Renú, Arturo; Laredo, Carlos; Lopez-Rueda, Antonio; Llull, Laura; Tudela, Raúl; San-Roman, Luis; Urra, Xabier; Blasco, Jordi; Macho, Juan; Oleaga, Laura; Chamorro, Angel; Amaro, Sergio

    2017-03-01

    Less than half of acute ischemic stroke patients treated with mechanical thrombectomy obtain permanent clinical benefits. Consequently, there is an urgent need to identify mechanisms implicated in the limited efficacy of early reperfusion. We evaluated the predictors and prognostic significance of vessel wall permeability impairment and its association with blood-cerebrospinal fluid barrier (BCSFB) disruption after acute stroke treated with thrombectomy. A prospective cohort of acute stroke patients treated with stent retrievers was analyzed. Vessel wall permeability impairment was identified as gadolinium vessel wall enhancement (GVE) in a 24- to 48-hour follow-up contrast-enhanced magnetic resonance imaging, and severe BCSFB disruption was defined as subarachnoid hemorrhage or gadolinium sulcal enhancement (present across >10 slices). Infarct volume was evaluated in follow-up magnetic resonance imaging, and clinical outcome was evaluated with the modified Rankin Scale at day 90. A total of 60 patients (median National Institutes of Health Stroke Scale score, 18) were analyzed, of whom 28 (47%) received intravenous alteplase before mechanical thrombectomy. Overall, 34 (57%) patients had GVE and 27 (45%) had severe BCSFB disruption. GVE was significantly associated with alteplase use before thrombectomy and with more stent retriever passes, along with the presence of severe BCSFB disruption. GVE was associated with poor clinical outcome, and both GVE and severe BCSFB disruption were associated with increased final infarct volume. These findings may support the clinical relevance of direct vessel damage and BCSFB disruption after acute stroke and reinforce the need for further improvements in reperfusion strategies. Further validation in larger cohorts of patients is warranted. © 2017 American Heart Association, Inc.

  1. [Characteristics of Distribution of Blood Vessels and Nerve Fibers in the Skin Tissues of Acupoint "Taichong" (LR 3) in the Rat].

    Science.gov (United States)

    Xu, Dong-Sheng; She, Chen; Wang, Jia; Cui, Jing-Jing; Cai, Hong; Bai, Wan-Zhu

    2016-12-25

    To investigate the microstructure (blood vessels and nerve fibers) of the skin tissue in "Taichong" (LR 3) region for reveling morphological characteristics of acupoint. Five SD rats were used in the present study. The skin tissue in the region of acupoint LR 3 was taken from the dorsum of hind foot following transcardial perfusion with 4% paraformaldehyde. Then, the skin samples were sagittally or horizontally cut into sections (20 μm or 40 μm in the thickness) to be stained with Phalloidin and calcitonin gene related peptide (CGRP) by using fluorescent histochemistry and immunohistochemistry. The labeled vascular structure and nerve fibers were observed and recorded using fluorescent microscope and laser scanning confocal microscope. In the skin tissue of LR 3, different types of blood vessels labeled by phalliodin, including capillaries and glomera mainly distributing in the superficial layer of the dermis, and thicker blood vessels and their sub-branches mainly existing in the deeper layer of the dermis and the subcutaneous layer, were found. In addition, CGRP positive nerve fibers were found to run parallel to the thin blood vessels or to gather around the thicker blood vessels. From the subcutaneous la-yer to the epidermis, blood vessels and nerve fibers coexisted and formed a stereo-network structure. In the skin of LR 3 area, there exists a stereo-network structure consisting of different types of blood vessels and nerve fibers. Although this structure is not specifically associated with acupoint area alone, this result may provide a new sight to further understand the microstructure of acupoint.

  2. Chronic mild hypoxia promotes profound vascular remodeling in spinal cord blood vessels, preferentially in white matter, via an α5β1 integrin-mediated mechanism.

    Science.gov (United States)

    Halder, Sebok K; Kant, Ravi; Milner, Richard

    2018-05-01

    Spinal cord injury (SCI) leads to rapid destruction of neuronal tissue, resulting in devastating motor and sensory deficits. This is exacerbated by damage to spinal cord blood vessels and loss of vascular integrity. Thus, approaches that protect existing blood vessels or stimulate the growth of new blood vessels might present a novel approach to minimize loss or promote regeneration of spinal cord tissue following SCI. In light of the remarkable power of chronic mild hypoxia (CMH) to stimulate vascular remodeling in the brain, the goal of this study was to examine how CMH (8% O 2 for up to 7 days) affects blood vessel remodeling in the spinal cord. We found that CMH promoted the following: (1) endothelial proliferation and increased vascularity as a result of angiogenesis and arteriogenesis, (2) increased vascular expression of the angiogenic extracellular matrix protein fibronectin as well as concomitant increases in endothelial expression of the fibronectin receptor α5β1 integrin, (3) strongly upregulated endothelial expression of the tight junction proteins claudin-5, ZO-1 and occludin and (4) astrocyte activation. Of note, the vascular remodeling changes induced by CMH were more extensive in white matter. Interestingly, hypoxic-induced vascular remodeling in spinal cord blood vessels was markedly attenuated in mice lacking endothelial α5 integrin expression (α5-EC-KO mice). Taken together, these studies demonstrate the considerable remodeling potential of spinal cord blood vessels and highlight an important angiogenic role for the α5β1 integrin in promoting endothelial proliferation. They also imply that stimulation of the α5β1 integrin or controlled use of mild hypoxia might provide new approaches for promoting angiogenesis and improving vascular integrity in spinal cord blood vessels.

  3. Genetically modified T cells targeting neovasculature efficiently destroy tumor blood vessels, shrink established solid tumors and increase nanoparticle delivery.

    Science.gov (United States)

    Fu, Xinping; Rivera, Armando; Tao, Lihua; Zhang, Xiaoliu

    2013-11-15

    Converting T cells into tumor cell killers by grafting them with a chimeric antigen receptor (CAR) has shown promise as a cancer immunotherapeutic. However, the inability of these cells to actively migrate and extravasate into tumor parenchyma has limited their effectiveness in vivo. Here we report the construction of a CAR containing an echistatin as its targeting moiety (eCAR). As echistatin has high binding affinity to αvβ3 integrin that is highly expressed on the surface of endothelial cells of tumor neovasculature, T cells engrafted with eCAR (T-eCAR) can efficiently lyse human umbilical vein endothelial cells and tumor cells that express αvβ3 integrin when tested in vitro. Systemic administration of T-eCAR led to extensive bleeding in tumor tissues with no evidence of damage to blood vessels in normal tissues. Destruction of tumor blood vessels by T-eCAR significantly inhibited the growth of established bulky tumors. Moreover, when T-eCAR was codelivered with nanoparticles in a strategically designed temporal order, it dramatically increased nanoparticle deposition in tumor tissues, pointing to the possibility that it may be used together with nanocarriers to increase their capability to selectively deliver antineoplastic drugs to tumor tissues. Copyright © 2013 UICC.

  4. Treatment of radiation exposure and regeneration medicine. Regeneration treatment of blood vessels by transplantation of autologous marrow monocytes

    International Nuclear Information System (INIS)

    Nagai, Kazuhiro; Kamihira, Shimeru; Matsumaru, Ichiro; Fukushima, Takuya; Yamaguchi, Hakuichiro; Miyazaki, Yasushi; Yamachika, Shiro; Eishi, Kiyoyuki; Tomonaga, Masao

    2007-01-01

    Described are usefulness and future view of regenerative medicine in the treatment of radiation exposure as exemplified by the vascular regeneration by autologous marrow cell transplantation. Vascular endothelial cells (VEC), possessing a high ability to divide, are known sensitive to radiation, which gives damage of blood vessel to alter its permeability leading to apoptosis of VEC, organ/tissue injuries and final damages in the cerebral blood vessels, central nervous system and skin, the acute radiation syndrome (ARS). Authors present successful cases of patients with chronic limb ischemia in the Therapeutic Angiogenesis using Cell Transplantation Trial (TACT), to whom the treatment is conducted with transplantation of autologous marrow monocyte fraction containing endothelial progenitor cells that differentiate to VEC. As well, they touch on a case of the patient encountered in a nuclear accident, mentioning that VEC are found partly derived from the donor after heamatopoietic stem cell transplantation (HSCT). Efficacy of HSCT in a literature is reviewed and commented to be an only limited one in 31 patients of various radiation accidents. However, treatment of ARS where stem cells are target, with regenerative medicine will become more useful in future, as basic and clinical researches will provide requisite findings. (T.I.)

  5. Mutation of p107 exacerbates the consequences of Rb loss in embryonic tissues and causes cardiac and blood vessel defects.

    Science.gov (United States)

    Berman, Seth D; West, Julie C; Danielian, Paul S; Caron, Alicia M; Stone, James R; Lees, Jacqueline A

    2009-09-01

    The retinoblastoma tumor-suppressor protein, pRb, is a member of the pocket protein family that includes p107 and p130. These proteins have well-defined roles in regulating entry into and exit from the cell cycle and also have cell cycle-independent roles in facilitating differentiation. Here we investigate the overlap between pocket protein's function during embryonic development by using conditional mutant alleles to generate Rb;p107 double-mutant embryos (DKOs) that develop in the absence of placental defects. These DKOs die between e13.5 and e14.5, much earlier than either the conditional Rb or the germline p107 single mutants, which survive to birth or are largely viable, respectively. Analyses of the e13.5 DKOs shows that p107 mutation exacerbates the phenotypes resulting from pRb loss in the central nervous system and lens, but not in the peripheral nervous system. In addition, these embryos exhibit novel phenotypes, including increased proliferation of blood vessel endothelial cells, and heart defects, including double-outlet right ventricle (DORV). The DORV is caused, at least in part, by a defect in blood vessel endothelial cells and/or heart mesenchymal cells. These findings demonstrate novel, overlapping functions for pRb and p107 in numerous murine tissues.

  6. Bone morphogenetic protein signaling promotes morphogenesis of blood vessels, wound epidermis, and actinotrichia during fin regeneration in zebrafish.

    Science.gov (United States)

    Thorimbert, Valentine; König, Désirée; Marro, Jan; Ruggiero, Florence; Jaźwińska, Anna

    2015-10-01

    Zebrafish fin regeneration involves initial formation of the wound epidermis and the blastema, followed by tissue morphogenesis. The mechanisms coordinating differentiation of distinct tissues of the regenerate are poorly understood. Here, we applied pharmacologic and transgenic approaches to address the role of bone morphogenetic protein (BMP) signaling during fin restoration. To map the BMP transcriptional activity, we analyzed the expression of the evolutionarily conserved direct phospho-Smad1 target gene, id1, and its homologs id2a and id3. This analysis revealed the BMP activity in the distal blastema, wound epidermis, osteoblasts, and blood vessels of the regenerate. Blocking the BMP function with a selective chemical inhibitor of BMP type I receptors, DMH1, suppressed id1 and id3 expression and arrested regeneration after blastema formation. We identified several previously uncharacterized functions of BMP during fin regeneration. Specifically, BMP signaling is required for remodeling of plexus into structured blood vessels in the rapidly growing regenerate. It organizes the wound epithelium by triggering wnt5b expression and promoting Collagen XIV-A deposition into the basement membrane. BMP represents the first known signaling that induces actinotrichia formation in the regenerate. Our data reveal a multifaceted role of BMP for coordinated morphogenesis of distinct tissues during regeneration of a complex vertebrate appendage. © FASEB.

  7. Erythropoietin-enhanced endothelial progenitor cell recruitment in peripheral blood and renal vessels during experimental acute kidney injury in rats.

    Science.gov (United States)

    Cakiroglu, Figen; Enders-Comberg, Sora Maria; Pagel, Horst; Rohwedel, Jürgen; Lehnert, Hendrik; Kramer, Jan

    2016-03-01

    Beneficial effects of erythropoietin (EPO) have been reported in acute kidney injury (AKI) when administered prior to induction of AKI. We studied the effects of EPO administration on renal function shortly after ischemic AKI. For this purpose, rats were subjected to renal ischemia for 30 min and EPO was administered at a concentration of 500 U/kg either i.v. as a single shot directly after ischemia or with an additional i.p. dose until 3 days after surgery. The results were compared with AKI rats without EPO application and a sham-operated group. Renal function was assessed by measurement of serum biochemical markers, histological grading, and using an isolated perfused kidney (IPK) model. Furthermore, we performed flow cytometry to analyze the concentration of endothelial progenitor cells (EPCs) in the peripheral blood and renal vessels. Following EPO application, there was only a statistically non-significant tendency of serum creatinine and urea to improve, particularly after daily EPO application. Renal vascular resistance and the renal perfusion rate were not significantly altered. In the histological analysis, acute tubular necrosis was only marginally ameliorated following EPO administration. In summary, we could not demonstrate a significant improvement in renal function when EPO was applied after AKI. Interestingly, however, EPO treatment resulted in a highly significant increase in CD133- and CD34-positive EPC both in the peripheral blood and renal vessels. © 2015 International Federation for Cell Biology.

  8. The influence of surrogate blood vessels on the impact response of a physical model of the brain.

    Science.gov (United States)

    Parnaik, Yednesh; Beillas, Philippe; Demetropoulos, Constantine K; Hardy, Warren N; Yang, King H; King, Albert I

    2004-11-01

    Cerebral blood vessels are an integral part of the brain and may play a role in the response of the brain to impact. The purpose of this study was to quantify the effects of surrogate vessels on the deformation patterns of a physical model of the brain under various impact conditions. Silicone gel and tubing were used as surrogates for brain tissue and blood vessels, respectively. Two aluminum cylinders representing a coronal section of the brain were constructed. One cylinder was filled with silicone gel only, and the other was filled with silicone gel and silicone tubing arranged in the radial direction in the peripheral region. An array of markers was embedded in the gel in both cylinders to facilitate strain calculation via high-speed video analysis. Both cylinders were simultaneously subjected to a combination of linear and angular acceleration using a two-segment pendulum. Marker motion was tracked, and maximum shear strain (MSS) and maximum principal strain (MPS) were calculated using markers clustered in groups of three. Four test series were conducted. Peak angular acceleration varied from 2,600 to 26,000 rad/s2, and peak angular speed varied from 17 to 29 rad/s. For a given impact condition, the test-to-test variation of these values was less than 5.5%. For all clusters, the peak MSS and peak MPS for both physical models were less than 26% and 32%, respectively. For 90% of the cluster locations, the absolute value of the difference in peak MSS and peak MPS between the physical models was 4% and 6%, respectively. In the physical model with tubing, strain tended to decrease in the periphery (near to the tubing), while it tended to increase toward the center (away from the tubing). Strain amplitudes were found to be sensitive to the peak angular speeds. In general, this study suggests that the vasculature could influence the deformation response of the brain.

  9. Blood vessel formation during tail regeneration in the leopard gecko (Eublepharis macularius): The blastema is not avascular.

    Science.gov (United States)

    Payne, Samantha L; Peacock, Hanna M; Vickaryous, Matthew K

    2017-03-01

    Unique among amniotes, many lizards are able to self-detach (autotomize) their tail and then regenerate a replacement. Tail regeneration involves the formation of a blastema, an accumulation of proliferating cells at the site of autotomy. Over time, cells of the blastema give rise to most of the tissues in the replacement tail. In non-amniotes capable of regenerating (such as urodeles and some teleost fish), the blastema is reported to be essentially avascular until tissue differentiation takes place. For tail regenerating lizards less is known. Here, we investigate neovascularization during tail regeneration in the leopard gecko (Eublepharis macularius). We demonstrate that the gecko tail blastema is not an avascular structure. Beginning with the onset of regenerative outgrowth, structurally mature (mural cell supported) blood vessels are found within the blastema. Although the pattern of blood vessel distribution in the regenerate tail differs from that of the original, a hierarchical network is established, with vessels of varying luminal diameters and wall thicknesses. Using immunostaining, we determine that blastema outgrowth and tissue differentiation is characterized by a dynamic interplay between the pro-angiogenic protein vascular endothelial growth factor (VEGF) and the anti-angiogenic protein thrombospondin-1 (TSP-1). VEGF-expression is initially widespread, but diminishes as tissues differentiate. In contrast, TSP-1 expression is initially restricted but becomes more abundant as VEGF-expression wanes. We predict that variation in the neovascular response observed between different regeneration-competent species likely relates to the volume of the blastema. J. Morphol. 278:380-389, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  10. Peripheral layer viscosity on the stenotic blood vessels for Herschel-Bulkley fluid model

    Directory of Open Access Journals (Sweden)

    G. Neeraja

    2017-01-01

    Full Text Available This paper deals with a theoretical investigation of blood flow in an arterial fragment with the existence of stenosis. The stream-wise blood is treated as steady and it is composed of two layers (the central core and plasma. The blood is taken to be non-Newtonian liquid described with help of Herschel-Bulkley fluid model. The artery is simulated as a cylindrical tube. Flow of blood is considered as steady. An extensive quantitative exploration has been performed through numerical computations of the flow physical parameters (the velocity, mass flux and shear stress. It is found that the mass-flux reduced as the consistency of peripheral layer fluid decreases, this happens due to the enhancement of pseudo plastic nature of the blood.

  11. Transcriptomic biomarkers of altered erythropoiesis to detect autologous blood transfusion.

    Science.gov (United States)

    Salamin, Olivier; Mignot, Jonathan; Kuuranne, Tiia; Saugy, Martial; Leuenberger, Nicolas

    2018-03-01

    Autologous blood transfusion is a powerful means of improving performance and remains one of the most challenging methods to detect. Recent investigations have identified 3 candidate reticulocytes genes whose expression was significantly influenced by blood transfusion. Using quantitative reverse transcription polymerase chain reaction as an alternative quantitative method, the present study supports that delta-aminolevulinate synthase 2 (ALAS2), carbonic anhydrase (CA1), and solute carrier family 4 member 1 (SLC4A1) genes are down-regulated post-transfusion. The expression of these genes exhibited stronger correlation with immature reticulocyte fraction than with reticulocytes percentage. Moreover, the repression of reticulocytes' gene expression was more pronounced than the diminution of immature reticulocyte fraction and reticulocyte percentage following blood transfusion. It suggests that the 3 candidate genes are reliable predictors of bone marrow's response to blood transfusion and that they represent potential biomarkers for the detection of this method prohibited in sports. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Endothelial cell hyperproliferation and stratification in uteroplacental blood vessels of the black mastiff bat, Molossus rufus.

    Science.gov (United States)

    Rasweiler, J J; Badwaik, N K; Salame, G; Abulafia, O

    2011-09-01

    Placentation was studied histologically and immunocytochemically in black mastiff bats obtained at frequent intervals throughout pregnancy. These were bred in a captive colony or collected from a reproductively-synchronized wild population. During late pregnancy, the single fetus was largely sustained by a discoidal, hemochorial placenta located at the cranial end of the right uterine horn. This invariant positioning was determined by a vascular tuft that developed there both during early pregnancy and non-pregnant cycles. This provided a scaffold for early placental morphogenesis. As development proceeded, small arterioles and venules serving the tuft were converted to large uteroplacental vessels. Within the base of the placenta, these became lined by an unusual vascular epithelium composed of intermingled patches of multilayered endothelial cells and cytotrophoblast. Initially, the endothelium became multilayered by hypertrophy, proliferation, and infolding of its basal lamina. These created endothelial bilayers usually insinuated between basal laminae. The development of temporary gaps in the laminae then permitted further enlargement of the vessels and proliferation of the endothelial cells as monolayer sheets or chains. The latter were interconnected, forming a complex, stratified, cellular network associated with a prominent meshwork of basal laminae. Throughout much of pregnancy, these endothelial cells were cuboidal to columnar and possessed an abundance of basal glycoprotein granules presumably containing basal lamina precursors. The cells also expressed vimentin and frequently von Willebrand factor, but not cytokeratins or desmin. Pronounced thickening of the endothelia and amplification of their basal laminae likely evolved to greatly strengthen the walls of the uteroplacental vessels. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.

    Science.gov (United States)

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir

    2012-06-01

    According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT

  14. Study for a portable IR sensor to detect the blood temperature during coronary bypass implantation

    Science.gov (United States)

    Giovannetti, Giulio; Hartwig, Valentina; Francesconi, Raffaello; Landini, Luigi; Benassi, Antonio

    2005-08-01

    The objective of this research was to investigate the possibility of using an infrared prototype device for the detection of the blood temperature during a surgical operation for coronary bypass implantation. The correlation between the fluid temperature time behavior and the fluid flow rate was demonstrated. Each blood vessel acts like a thermal wave emitter, so the amount of heat is proportional to the blood flow detected by the IR sensor. The idea was to design a low cost portable device with the advantage that it can be placed near the region of interest. We chose a pyroelectric sensor for its high-quality cost ratio. Because this kind of sensor detects only a variable infrared source, we used an electromechanical chopper for modulating the radiation. It consists of an electronic shutter whose opening speed is controlled by an astable multivibrator. The output signal was analyzed using a dedicated electronic circuit including a bandpass filter and an amplifier; then an acquisition board was employed for capturing and displaying the signal using a PC. Prototype assessment was made with laboratory equipment and in vivo measurements were made during surgical operation on a small pig.

  15. DNA Microarray Detection of 18 Important Human Blood Protozoan Species.

    Science.gov (United States)

    Chen, Mu-Xin; Ai, Lin; Chen, Jun-Hu; Feng, Xin-Yu; Chen, Shao-Hong; Cai, Yu-Chun; Lu, Yan; Zhou, Xiao-Nong; Chen, Jia-Xu; Hu, Wei

    2016-12-01

    Accurate detection of blood protozoa from clinical samples is important for diagnosis, treatment and control of related diseases. In this preliminary study, a novel DNA microarray system was assessed for the detection of Plasmodium, Leishmania, Trypanosoma, Toxoplasma gondii and Babesia in humans, animals, and vectors, in comparison with microscopy and PCR data. Developing a rapid, simple, and convenient detection method for protozoan detection is an urgent need. The microarray assay simultaneously identified 18 species of common blood protozoa based on the differences in respective target genes. A total of 20 specific primer pairs and 107 microarray probes were selected according to conserved regions which were designed to identify 18 species in 5 blood protozoan genera. The positive detection rate of the microarray assay was 91.78% (402/438). Sensitivity and specificity for blood protozoan detection ranged from 82.4% (95%CI: 65.9% ~ 98.8%) to 100.0% and 95.1% (95%CI: 93.2% ~ 97.0%) to 100.0%, respectively. Positive predictive value (PPV) and negative predictive value (NPV) ranged from 20.0% (95%CI: 2.5% ~ 37.5%) to 100.0% and 96.8% (95%CI: 95.0% ~ 98.6%) to 100.0%, respectively. Youden index varied from 0.82 to 0.98. The detection limit of the DNA microarrays ranged from 200 to 500 copies/reaction, similar to PCR findings. The concordance rate between microarray data and DNA sequencing results was 100%. Overall, the newly developed microarray platform provides a convenient, highly accurate, and reliable clinical assay for the determination of blood protozoan species.

  16. Vessel Pattern Knowledge Discovery from AIS Data: A Framework for Anomaly Detection and Route Prediction

    Directory of Open Access Journals (Sweden)

    Karna Bryan

    2013-06-01

    Full Text Available Understanding maritime traffic patterns is key to Maritime Situational Awareness applications, in particular, to classify and predict activities. Facilitated by the recent build-up of terrestrial networks and satellite constellations of Automatic Identification System (AIS receivers, ship movement information is becoming increasingly available, both in coastal areas and open waters. The resulting amount of information is increasingly overwhelming to human operators, requiring the aid of automatic processing to synthesize the behaviors of interest in a clear and effective way. Although AIS data are only legally required for larger vessels, their use is growing, and they can be effectively used to infer different levels of contextual information, from the characterization of ports and off-shore platforms to spatial and temporal distributions of routes. An unsupervised and incremental learning approach to the extraction of maritime movement patterns is presented here to convert from raw data to information supporting decisions. This is a basis for automatically detecting anomalies and projecting current trajectories and patterns into the future. The proposed methodology, called TREAD (Traffic Route Extraction and Anomaly Detection was developed for different levels of intermittency (i.e., sensor coverage and performance, persistence (i.e., time lag between subsequent observations and data sources (i.e., ground-based and space-based receivers.

  17. Distribution of Vascular Patterns in Different Subtypes of Renal Cell Carcinoma. A Morphometric Study in Two Distinct Types of Blood Vessels.

    Science.gov (United States)

    Ruiz-Saurí, Amparo; García-Bustos, V; Granero, E; Cuesta, S; Sales, M A; Marcos, V; Llombart-Bosch, A

    2017-07-01

    To analyze the presence of mature and immature vessels as a prognostic factor in patients with renal cell carcinoma and propose a classification of renal cancer tumor blood vessels according to morphometric parameters. Tissue samples were obtained from 121 renal cell carcinoma patients who underwent radical nephrectomy. Staining with CD31 and CD34 was used to differentiate between immature (CD31+) and mature (CD34+) blood vessels. We quantified the microvascular density, microvascular area and different morphometric parameters: maximum diameter, minimum diameter, major axis, minor axis, perimeter, radius ratio and roundness. We found that the microvascular density was higher in CD31+ than CD34+ vessels, but CD34+ vessels were larger than CD31+ vessels, as well as being strongly correlated with the ISUP tumor grade. We also identified four vascular patterns: pseudoacinar, fascicular, reticular and diffuse. Pseudoacinar and fascicular patterns were more frequent in clear cell renal cell carcinoma (37.62 and 35.64% respectively), followed by reticular pattern (21.78%), while in chromophobe tumors the reticular pattern predominated (90%). The isolated pattern was present in all papillary tumors (100%). In healthy renal tissue, the pseudoacinar and isolated patterns were differentially found in the renal cortex and medulla respectively. We defined four distinct vascular patterns significantly related with the ISUP tumor grade in renal cell carcinomas. Further studies in larger series are needed in order to validate these results. Analysis of both mature and immature vessels (CD34+ and CD31+) provides additional information when evaluating microvascular density.

  18. Nanostructural haemocompatible coatings for the internal side of artificial blood vessels

    Science.gov (United States)

    Trembecka-Wojciga, K.; Major, R.; Lackner, J. M.; Butruk-Raszeja, B.; Sanak, M.; Major, B.

    2016-03-01

    The main goal of the work was to elaborate low thrombogenicity of surface inside tube-like elements for cardiovascular system support by combination of low-temperature glow discharge and hydrogel coatings to inhibit blood-clotting cascade activation. A large share of amorphous phase silicon was observed in the microstructure analysis. The crystalline elements were uniformly distributed in the amorphous structure. Combination of low thickness, the proper microstructure and density of the coatings provided a highly flexible nature of the whole system. The blood-material interaction was analyzed in vitro in dynamic conditions by using a designed and fabricated novel blood flow simulator. Coatings deposited by the glow discharge expressed good hemocopatibile properties. The use of hydrogel coatings did not reduce coagulation parameter. Hydrogel coatings did not improve the hemocompatibility of the surface modified with carbon based coatings. Modification of surface with hydrogel resulted in further increased risk of hemolysis.

  19. Retinal blood vessel segmentation using line operators and support vector classification.

    Science.gov (United States)

    Ricci, Elisa; Perfetti, Renzo

    2007-10-01

    In the framework of computer-aided diagnosis of eye diseases, retinal vessel segmentation based on line operators is proposed. A line detector, previously used in mammography, is applied to the green channel of the retinal image. It is based on the evaluation of the average grey level along lines of fixed length passing through the target pixel at different orientations. Two segmentation methods are considered. The first uses the basic line detector whose response is thresholded to obtain unsupervised pixel classification. As a further development, we employ two orthogonal line detectors along with the grey level of the target pixel to construct a feature vector for supervised classification using a support vector machine. The effectiveness of both methods is demonstrated through receiver operating characteristic analysis on two publicly available databases of color fundus images.

  20. BLOOD VESSELS SEGMENTATION BY RADIAL GRADIENT SYMMETRY METHOD VIA DIFFERENT THRESHOLD VALUES

    Directory of Open Access Journals (Sweden)

    Kumar Parasuraman

    2015-02-01

    Full Text Available A Key identifier for some diseases such as arteriosclerosis, hypertension, macular edema, diabetes mellitus, and the recognition qualities of geometrical changes in retinal veins and supply routes are recognized by Retinal Vein morphology and might be connected to a mixed carrier of clinical studies. Extraction of the retinal veins is a help to see all the more about its morphology and will give a superior wellspring of data for contemplating the different related diseases. Two of the significant issues in the extraction of retinal veins are the vicinity of a wide assortment of vessel widths and inhomogeneous foundation of the retina. Machine based dissection for computerized extraction of veins in retinal images will help eye mind pro's screen bigger populaces for vessel variations from the norm. In this extend a technique for robotized extraction of fundus pictures of the retinal vein is introduced. This paper displays another strategy for vein recognition in computerized retinal pictures. In this system first separating is carried out utilizing reciprocal channel to uproot the commotions in the picture and second, differentiates the fundus picture into red, green and blue channels. Third, Kirsch's format with spatial separating is utilized to discover the beginning and bearing of the veins and for smoothing the limits. Fourth, the veins are fragmented by applying threshold values and by utilizing outspread radial symmetry strategy. These segmentations are looked at against manual estimations and between imaging strategies. Its adequacy and strength with distinctive picture conditions, together with its smoothness and quick usage, make this vein division proposal suitable for retinal picture workstation examination, for example, computerized screening for right on time diabetic retinopathy discovery.

  1. Completing fishing monitoring with spaceborne Vessel Detection System (VDS) and Automatic Identification System (AIS) to assess illegal fishing in Indonesia.

    Science.gov (United States)

    Longépé, Nicolas; Hajduch, Guillaume; Ardianto, Romy; Joux, Romain de; Nhunfat, Béatrice; Marzuki, Marza I; Fablet, Ronan; Hermawan, Indra; Germain, Olivier; Subki, Berny A; Farhan, Riza; Muttaqin, Ahmad Deni; Gaspar, Philippe

    2017-10-26

    The Indonesian fisheries management system is now equipped with the state-of-the-art technologies to deter and combat Illegal, Unreported and Unregulated (IUU) fishing. Since October 2014, non-cooperative fishing vessels can be detected from spaceborne Vessel Detection System (VDS) based on high resolution radar imagery, which directly benefits to coordinated patrol vessels in operation context. This study attempts to monitor the amount of illegal fishing in the Arafura Sea based on this new source of information. It is analyzed together with Vessel Monitoring System (VMS) and satellite-based Automatic Identification System (Sat-AIS) data, taking into account their own particularities. From October 2014 to March 2015, i.e. just after the establishment of a new moratorium by the Indonesian authorities, the estimated share of fishing vessels not carrying VMS, thus being illegal, ranges from 42 to 47%. One year later in January 2016, this proportion decreases and ranges from 32 to 42%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Radiometric detection of yeasts in blood cultures of cancer patients

    International Nuclear Information System (INIS)

    Hopfer, R.L.; Orengo, A.; Chesnut, S.; Wenglar, M.

    1980-01-01

    During a 12-month period, 19,457 blood cultures were collected. Yeasts were isolated from 193 cultures derived from 76 cancer patients. Candida albicans or Candida tropicalis accounted for 79% of isolates. Of the three methods compared, the radiometric method required 2.9 days to become positive, blind subculture required 2.6 days, and Gram stains required 1 day. However, the radiometric method was clearly superior in detecting positive cultures, since 73% of all cultures were first detected radiometrically, 22% were detected by subculture, and only 5% were detected by Gram stain. Although 93% of the isolates were detected by aerobic culture, five (7%) isolates were obtained only from anaerobic cultures. Seven days of incubation appear to be sufficient for the radiometric detection of yeasts

  3. Blood-Vessel Mimicking Structures by Stereolithographic Fabrication of Small Porous Tubes Using Cytocompatible Polyacrylate Elastomers, Biofunctionalization and Endothelialization

    Directory of Open Access Journals (Sweden)

    Birgit Huber

    2016-04-01

    Full Text Available Blood vessel reconstruction is still an elusive goal for the development of in vitro models as well as artificial vascular grafts. In this study, we used a novel photo-curable cytocompatible polyacrylate material (PA for freeform generation of synthetic vessels. We applied stereolithography for the fabrication of arbitrary 3D tubular structures with total dimensions in the centimeter range, 300 µm wall thickness, inner diameters of 1 to 2 mm and defined pores with a constant diameter of approximately 100 µm or 200 µm. We established a rinsing protocol to remove remaining cytotoxic substances from the photo-cured PA and applied thio-modified heparin and RGDC-peptides to functionalize the PA surface for enhanced endothelial cell adhesion. A rotating seeding procedure was introduced to ensure homogenous endothelial monolayer formation at the inner luminal tube wall. We showed that endothelial cells stayed viable and adherent and aligned along the medium flow under fluid-flow conditions comparable to native capillaries. The combined technology approach comprising of freeform additive manufacturing (AM, biomimetic design, cytocompatible materials which are applicable to AM, and biofunctionalization of AM constructs has been introduced as BioRap® technology by the authors.

  4. Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Lisa C.; Boeker, Sarah M.; Bender, Yvonne Y.; Fallenberg, Eva M.; Wagner, Moritz; Hamm, Bernd; Makowski, Marcus R. [Department of Radiology, Charite, Berlin (Germany); Liebig, Thomas [Department of Neuroradiology, Charite, Berlin (Germany)

    2017-09-15

    Calcification of the brain supplying arteries has been linked to an increased risk for cerebrovascular disease. The purpose of this study was to test the potential of susceptibility weighted MR imaging (SWMR) for the detection of vertebral artery calcifications, based on CT as a reference standard. Four hundred seventy-four patients, who had received head CT and 1.5 T MR scans with SWMR, including the distal vertebral artery, between January 2014 and December 2016, were retrospectively evaluated and 389 patients were included. Sensitivity and specificity for the detection of focal calcifications and intra- and interobserver agreement were calculated for SWMR and standard MRI, using CT as a standard of reference. The diameter of vertebral artery calcifications was used to assess correlations between imaging modalities. Furthermore, the degree of vessel stenosis was determined in 30 patients, who had received an additional angiography. On CT scans, 40 patients showed a total of 52 vertebral artery calcifications. While SWMR reached a sensitivity of 94% (95% CI 84-99%) and a specificity of 97% (95% CI 94-98%), standard MRI yielded a sensitivity of 33% (95% CI 20-46%), and a specificity of 93% (95% CI 90-96%). Linear regression analysis of size measurements confirmed a close correlation between SWMR and CT measurements (R {sup 2} = 0.74, p < 0.001). Compared to standard MRI (ICC = 0.52; CI 0.45-0.59), SWMR showed a higher interobserver agreement for calcification measurements (ICC = 0.84; CI 0.81-0.87). For detection of distal vertebral artery calcifications, SWMR demonstrates a performance comparable to CT and considerably higher than conventional MRI. (orig.)

  5. CLASSICAL AREAS OF PHENOMENOLOGY: Lattice Boltzmann simulation of behaviour of particles moving in blood vessels under the rolling massage

    Science.gov (United States)

    Yi, Hou-Hui; Yang, Xiao-Feng; Wang, Cai-Feng; Li, Hua-Bing

    2009-07-01

    The rolling massage is one of the most important manipulations in Chinese massage, which is expected to eliminate many diseases. Here, the effect of the rolling massage on a pair of particles moving in blood vessels under rolling massage manipulation is studied by the lattice Boltzmann simulation. The simulated results show that the motion of each particle is considerably modified by the rolling massage, and it depends on the relative rolling velocity, the rolling depth, and the distance between particle position and rolling position. Both particles' translational average velocities increase almost linearly as the rolling velocity increases, and obey the same law. The increment of the average relative angular velocity for the leading particle is smaller than that of the trailing one. The result is helpful for understanding the mechanism of the massage and to further develop the rolling techniques.

  6. New approach to carbon monoxide poisoning treatment by laser-induced photodissociation of carboxyhemoglobin of cutaneous blood vessels

    Science.gov (United States)

    Asimov, Mustafo M.; Asimov, Rustam M.; Gisbrecht, Alexander

    2005-04-01

    A new approach to carbon monoxide poisoning treatment based on laser-induced photodissociation of the carboxyhemoglobin is proposed. Using the simple model of laser tissue interaction the action spectra of laser radiation on carboxyhemoglobin of cutaneous blood vessels has been calculated. The results of the calculatoins indicate that there is a relatively narrow spectral range in the visible region where one could effectively irradiate carboxyhemoglobin through the tissue not in a deep distances. In the case of deeper penetration, the action spectra of laser radiation shifts toward the longer wavelength region. Despite the similarity of the carboxyhemoglobin and oxyhemoglobin action spectra, the significant difference in quantum yields of photodissociation makes possible to develop an effective method of carbon monoxide poisoning treatment.

  7. The corn snake yolk sac becomes a solid tissue filled with blood vessels and yolk-rich endodermal cells.

    Science.gov (United States)

    Elinson, Richard P; Stewart, James R

    2014-01-01

    The amniote egg was a key innovation in vertebrate evolution because it supports an independent existence in terrestrial environments. The egg is provisioned with yolk, and development depends on the yolk sac for the mobilization of nutrients. We have examined the yolk sac of the corn snake Pantherophis guttatus by the dissection of living eggs. In contrast to the familiar fluid-filled sac of birds, the corn snake yolk sac invades the yolk mass to become a solid tissue. There is extensive proliferation of yolk-filled endodermal cells, which associate with a meshwork of blood vessels. These novel attributes of the yolk sac of corn snakes compared with birds suggest new pathways for the evolution of the amniote egg.

  8. Counterflow Dielectrophoresis for Trypanosome Enrichment and Detection in Blood

    Science.gov (United States)

    Menachery, Anoop; Kremer, Clemens; Wong, Pui E.; Carlsson, Allan; Neale, Steven L.; Barrett, Michael P.; Cooper, Jonathan M.

    2012-10-01

    Human African trypanosomiasis or sleeping sickness is a deadly disease endemic in sub-Saharan Africa, caused by single-celled protozoan parasites. Although it has been targeted for elimination by 2020, this will only be realized if diagnosis can be improved to enable identification and treatment of afflicted patients. Existing techniques of detection are restricted by their limited field-applicability, sensitivity and capacity for automation. Microfluidic-based technologies offer the potential for highly sensitive automated devices that could achieve detection at the lowest levels of parasitemia and consequently help in the elimination programme. In this work we implement an electrokinetic technique for the separation of trypanosomes from both mouse and human blood. This technique utilises differences in polarisability between the blood cells and trypanosomes to achieve separation through opposed bi-directional movement (cell counterflow). We combine this enrichment technique with an automated image analysis detection algorithm, negating the need for a human operator.

  9. Detection of Streptococcus pneumoniae in whole blood by PCR.

    Science.gov (United States)

    Zhang, Y; Isaacman, D J; Wadowsky, R M; Rydquist-White, J; Post, J C; Ehrlich, G D

    1995-03-01

    Streptococcus pneumoniae is a major cause of bacteremia in both children and adults. Currently, the diagnosis of pneumococcal bacteremia relies on the isolation and identification of the bacteria from blood cultures. We have developed a sensitive assay for the detection of S. pneumoniae in whole blood by the PCR. A specific primer-probe set (JM201 and JM202 primers with JM204 probe) designed from the penicillin-binding protein 2B gene was demonstrated to reproducibly detect between 10 and 100 fg of input purified S. pneumoniae DNA. This assay system was shown to be inclusive for all strains of S. pneumoniae evaluated, including 15 different serotypes and a battery of penicillin-resistant and -sensitive strains. The specificity of this PCR-based assay was demonstrated by its inability to support amplification from a series of human, bacterial, and yeast genomic DNAs. A general specimen preparation method which should be suitable for the purification of DNA from any pathogens in whole blood was developed. With this protocol it was possible to detect S. pneumoniae-specific DNA from whole blood specimens inoculated with as little as 4 CFU/ml. Copurified human blood DNA, ranging from 0 to 4.5 micrograms per PCR, did not affect the sensitivity of S. pneumoniae detection by PCR. A blinded clinical trial was used to compare the PCR-based assay with standard microbiological blood culture for the detection of S. pneumoniae bacteremia in 36 specimens obtained from pediatric patients seen in the emergency room of Children's Hospital of Pittsburgh. With culture as the "gold standard," the PCR-based assay had a sensitivity of 80% (4 of 5 culture-positive specimens were PCR positive) and a specificity of 84% (26 of 31 culture-negative specimens were PCR negative). However, three patients whose specimens were PCR positive and culture negative had histories suggestive of bacteremia, including recent positive blood cultures, treatment with antibiotics, cellulitis, and multiple

  10. MAPK and pro-inflammatory mediators in the walls of brain blood vessels following cerebral ischemia

    OpenAIRE

    Maddahi, Aida

    2012-01-01

    INTRODUCTION Stroke is a serious neurological disease which may lead to death and severe disability [1, 2]. There are two major types of stroke: ischemic and hemorrhagic stroke. Both are associated with disruption of blood flow to a part of the brain with rapid depletion of cellular energy and oxygen, resulting in ionic disturbances and eventually neuronal cell death [3]. The pathologic process that develops after stroke is divided into acute (within hours), sub-acute (hours to days), ...

  11. The feasibility of detecting cerebral blood flow direction using the indocyanine green video angiography.

    Science.gov (United States)

    Murai, Yasuo; Nakagawa, Syunsuke; Matano, Fumihiro; Shirokane, Kazutaka; Teramoto, Akira; Morita, Akio

    2016-10-01

    The intraoperative confirmation of blood flow direction is necessary in cerebral vascular surgery. Using indocyanine green video angiography (ICG-VAG) with the FLOW 800 system, we examined the transit time of the blood vessel of interest and semiquantitatively evaluated the delay time (T1/2max) from indocyanine green (ICG) injection into the donor artery in reconstructive surgery and the middle cerebral artery (MCA) in aneurysmal surgery. The direction of cerebral blood flow (CBF), which can often be confirmed by ICG-VAG, may be more difficult to determine with faster blood flow. Here, we report our findings regarding the feasibility of detecting CBF direction using the FLOW 800 system. Twenty patients undergoing superficial temporal artery (STA) to MCA anastomosis for carotid occlusive disease and 13 patients with a small MCA aneurysm clipping were evaluated using the T1/2max, semiquantitative method with the FLOW 800 system. In STA-MCA anastomosis cases, the regions of interest (ROIs) included: the proximal donor STA and a region more than 10 mm on the distal side of the donor STA near the anastomosis site. In MCA aneurysms, the ROIs included the proximal M1 and distal M2 sides of the MCA aneurysm. T1/2max was significantly shorter for the proximal sites compared to the distal sites for all subjects (ps direction of CBF can be determined using the FLOW 800 system.

  12. Microwave Ablation Using Four-Tine Antenna: Effects of Blood Flow Velocity, Vessel Location, and Total Displacement on Porous Hepatic Cancer Tissue

    Directory of Open Access Journals (Sweden)

    Montree Chaichanyut

    2016-01-01

    Full Text Available This research is concerned with microwave ablation analyses using a 2.45 GHz four-tine (4T antenna for hepatic cancer tissue. In the study, three-dimensional finite-element models were utilized to examine the tissue temperature distributions during and after MW ablation. A preliminary study was first carried out with regard to the specific absorption rates along the 4T antenna insertion depths and the temperature distributions inside the solid and porous liver models with either 3 cm-in-diameter tumor or 5 cm-in-diameter tumor. Based on the preliminary results, the porous models were further examined for the effect of varying blood flow velocities (0–200 cm/s with a 1 cm-in-diameter blood vessel next to the antenna and also for the effect of vessel-antenna locations (0, 0.8, and 1.3 cm with a constant blood flow velocity of 16.7 cm/s. All scenarios were simulated under temperature-controlled mode (90°C. The findings revealed that the blood flow velocity and vessel location influence the ablation effectiveness and that increased blood flow inhibits heat transfer to the vessel wall. At the nearest and farthest vessel-antenna locations (0 and 1.3 cm, approximately 90.3% and 99.55% of the cancer cells were eradicated except for the areas adjacent to the vessel. In addition, total tissue thermal displacement is 5.9 mm which is 6.59% of the total length of the overall model.

  13. A cellular nonlinear network: real-time technology for the analysis of microfluidic phenomena in blood vessels

    Science.gov (United States)

    Sapuppo, F.; Bucolo, M.; Intaglietta, M.; Fortuna, L.; Arena, P.

    2006-02-01

    A new approach to the observation and analysis of dynamic structural and functional parameters in the microcirculation is described. The new non-invasive optical system is based on cellular nonlinear networks (CNNs), highly integrated analogue processor arrays whose processing elements, the cells, interact directly within a finite local neighbourhood. CNNs, thanks to their parallel processing feature and spatially distributed structure, are widely used to solve high-speed image processing and recognition problems and in the description and modelling of biological dynamics through the solution of time continuous partial differential equations (PDEs). They are therefore considered extremely suitable for spatial-temporal dynamic characterization of fluidic phenomena at micrometric to nanometric scales, such as blood flow in microvessels and its interaction with the cells of the vessel wall. A CNN universal machine (CNN-UM) structure was used to implement, via simulation and hardware (ACE16k), the algorithms to determine the functional capillarity density (FCD) and red blood cell velocity (RBCV) in capillaries obtained by intravital microscopy during in vivo experiments on hamsters. The system exploits the moving particles to distinguish the functional capillaries from the stationary background. This information is used to reconstruct a map and to calculate the velocity of the moving objects.

  14. Multi-scale finite element analyses for stress and strain evaluations of braid fibril artificial blood vessel and smooth muscle cell.

    Science.gov (United States)

    Nakamachi, Eiji; Uchida, Takahiro; Kuramae, Hiroyuki; Morita, Yusuke

    2014-08-01

    In this study, we developed a multi-scale finite element (FE) analysis code to obtain the stress and strain that occurred in the smooth muscle cell (SMC) at micro-scale, which was seeded in the real fabricated braid fibril artificial blood vessel. This FE code can predict the dynamic response of stress under the blood pressure loading. We try to establish a computer-aided engineering (CAE)-driven scaffold design technique for the blood vessel regeneration. Until now, there occurred the great progresses for the endothelial cell activation and intima layer regeneration in the blood vessel regeneration study. However, there remains the difficulty of the SMC activation and media layer regeneration. Therefore, many researchers are now studying to elucidate the fundamental mechanism of SMC activation and media layer regeneration by using the biomechanical technique. As the numerical tool, we used the dynamic-explicit FE code PAM-CRASH, ESI Ltd. For the material models, the nonlinear viscoelastic constitutive law was adapted for the human blood vessel, SMC and the extra-cellular matrix, and the elastic law for the polyglycolic acid (PGA) fiber. Through macro-FE and micro-FE analyses of fabricated braid fibril tubes by using PGA fiber under the combined conditions of the orientation angle and the pitch of fiber, we searched an appropriate structure for the stress stimulation for SMC functionalization. Objectives of this study are indicated as follows: 1. to analyze the stress and strain of the human blood vessel and SMC, and 2. to calculate stress and strain of the real fabricated braid fibril artificial blood vessel and SMC to search an appropriate PGA fiber structure under combined conditions of PGA fiber numbers, 12 and 24, and the helical orientation angles of fiber, 15, 30, 45, 60, and 75 degrees. Finally, we found a braid fibril tube, which has an angle of 15 degree and 12 PGA fibers, as a most appropriate artificial blood vessel for SMC functionalization. Copyright

  15. Endothelial mineralocorticoid receptor ablation does not alter blood pressure, kidney function or renal vessel contractility

    DEFF Research Database (Denmark)

    Laursen, Sidsel B.; Finsen, Stine; Marcussen, Niels

    2018-01-01

    found between the groups with respect to urinary excretion of sodium after 4 weeks of AngII infusion, or in urinary albumin excretion and kidney morphology. In conclusion, deletion of the EC-MR does not confer protection towards the development of hypertension, endothelial dysfunction of renal arteries......Aldosterone blockade confers substantial cardiovascular and renal protection. The effects of aldosterone on mineralocorticoid receptors (MR) expressed in endothelial cells (EC) within the renal vasculature have not been delineated. We hypothesized that lack of MR in EC may be protective in renal...... vasculature and examined this by ablating the Nr3c2 gene in endothelial cells (EC-MR) in mice. Blood pressure, heart rate and PAH clearance were measured using indwelling catheters in conscious mice. The role of the MR in EC on contraction and relaxation was investigated in the renal artery and in perfused...

  16. Hydrogen Cyanide Related Deaths and Detection in the Blood

    Science.gov (United States)

    2012-01-01

    Borron SW, Baud FJ, Barriot P, Imbert M, Bismuth C. 2007. Prospective study of hydroxocobalamin for acute cyanide poisoning in smoke inhalation...AUG 2015 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Hydrogen cyanide related deaths and detection in the blood 5a...Stamyr K, Thelander G, Ernstgard L, Ahlner J, Johanson G. Swedish forensic data 1992–2009 suggest hydrogen cyanide as an impor- tant cause of death in

  17. Simulation of balloon angioplasty in residually stressed blood vessels-Application of a gradient-enhanced fibre damage model.

    Science.gov (United States)

    Polindara, César; Waffenschmidt, Tobias; Menzel, Andreas

    2016-08-16

    In this contribution we study the balloon angioplasty in a residually stressed artery by means of a non-local gradient-enhanced fibre damage model. The balloon angioplasty is a common surgical intervention used to extend or reopen narrowed blood vessels in order to restore the continuous blood flow in, for instance, atherosclerotic arteries. Inelastic, i.e. predominantly damage-related and elastoplastic processes are induced in the artery during its inflation resulting in an irreversible deformation. As a beneficial consequence, provided that the inelastic deformations do not exceed a specific limit, higher deformations can be obtained within the same pressure level and a continuous blood flow can be guaranteed. In order to study the mechanical response of the artery in this scenario, we make use of the non-local gradient-enhanced model proposed in Waffenschmidt et al. (2014). In this contribution, we extend this model to make use of an incompressible format in connection with a Q1Q1P0 finite element implementation. The residual stresses in the artery are also taken into account following the framework presented in Waffenschmidt (2015). From the results it becomes apparent that, when the artery is subjected to radial stresses beyond the physiological range, damage evolution is triggered in the collagen fibres. The impact of the residual stresses on the structural response and on the circumferential stress distribution along the thickness of the arterial wall is also studied. It is observed that the residual stresses have a beneficial effect on the mechanical response of the arterial wall. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Remote non-invasive stereoscopic imaging of blood vessels: first in-vivo results of a new multispectral contrast enhancement technology

    NARCIS (Netherlands)

    Wieringa, F.P.; Mastik, F.; Cate, F.J. ten; Neumann, H.A.M.; Steen, A.F.W. van der

    2006-01-01

    We describe a contactless optical technique selectively enhancing superficial blood vessels below variously pigmented intact human skin by combining images in different spectral bands. Two CMOS-cameras, with apochromatic lenses and dual-band LED-arrays, simultaneously streamed Left (L) and Right (R)

  19. Angiogenesis & Vasculogenesis: Inducing the growth of new blood vessels and wound healing by stimulation of Bone Marrow Derived Progenitor Cell Mobilization and Homing

    Science.gov (United States)

    Velazquez, Omaida C.

    2009-01-01

    During embryonic development, the vasculature is among the first organs to form and is in charge of maintaining metabolic homeostasis by supplying oxygen and nutrients and removing waste products. As one would expect, blood vessels are critical not only for organ growth in the embryo, but also for repair of wounded tissue in the adult. An imbalance in ‘Angiogenesis’ (a time-honored term that globally refers to the growth of new blood vessels) contributes to the pathogenesis of numerous malignant, inflammatory, ischemic, infectious, immune, and wound healing disorders. In this review, we will focus on the central role of the growth of new blood vessels in ischemic and diabetic wound healing. We define the most current nomenclature that describes the neovascularization process in wounds. There are now two well defined, distinct, yet interrelated processes for the formation of post-natal new blood vessels, angiogenesis and vasculogenesis. We review recent new data on vasculogenesis that promises to advance the field of wound healing. PMID:17544023

  20. Nutritional supplementation with L-arginine prevents pelvic radiation-induced changes in morphology, density, and regulating factors of blood vessels in the wall of rat bladder.

    Science.gov (United States)

    Costa, Waldemar S; Ribeiro, Monica N; Cardoso, Luiz E M; Dornas, Maria C; Ramos, Cristiane F; Gallo, Carla B M; Sampaio, Francisco J B

    2013-06-01

    To determine whether L-arginine has protective effects against radiation-induced alterations in the morphology and regulatory factors of vesical blood vessels in rats. Male rats aged 3-4 months were divided into groups of 10 animals each: (a) controls, consisting of non-treated animals; (b) radiated-only rats; and (c) radiated rats receiving L-arginine supplementation. Radiation was in one session of 10 Gy and was aimed at the pelvic-abdominal region. L-arginine was administered once a day (0.65 g/kg body weight), starting 7 days before radiation and continuing until killing on the 16th day after radiation. The density, relative area, and wall thickness of blood vessels were measured in the vesical lamina propria using histological methods, and the expression of vascular endothelial growth factor (VEGF) and fibroblast growth factors (FGF) in the bladder wall was assessed by RT-PCR. Compared with controls, radiation alone decreased the density and relative area of blood vessels by 32 % (p supplemented with L-arginine were not significantly different from controls. Pelvic radiation leads to significant vesical modifications, as in the morphology of blood vessels and in VEGF and FGF expression. All these changes, however, were prevented by L-arginine treatment. These results emphasize, therefore, the potential use of this amino acid as a radioprotective drug.

  1. Porous hybrid structures based on P(DLLA-co-TMC) and collagen for tissue engineering of small-diameter blood vessels

    NARCIS (Netherlands)

    Buttafoco, L.; Boks, Niels P.; Engbers-Buijtenhuijs, P.; Grijpma, Dirk W.; Poot, Andreas A.; Dijkstra, Pieter J.; Vermes, I.; Feijen, Jan

    2006-01-01

    Poly (D,L-lactide)-7co-(1,3-trimethylene carbonate) [P(DLLA-co-TMC)] (83 mol % DLLA) was used to produce matrices suitable for tissue engineering of small-diameter blood vessels. The copolymer was processed into tubular structures with a porosity of 98% by melt spinning and fiber winding, thus

  2. Clinicopathologic correlation of 282 leukocytoclastic vasculitis cases in a tertiary hospital: a focus on direct immunofluorescence findings at the blood vessel wall.

    Science.gov (United States)

    Takatu, Caroline Maris; Heringer, Antonio Pedro Ribeiro; Aoki, Valéria; Valente, Neusa Yuriko Sakai; de Faria Sanchez, Paula Cristina; de Carvalho, Jozélio Freire; Criado, Paulo Ricardo

    2017-02-01

    This is the largest direct immunofluorescence (DIF) analysis of patients with histology-proven cutaneous leukocytoclastic vasculitis (LCV). To establish the correlation of deposition of immune complexes at the blood vessel walls with underlying causes and prognosis of LCV, we performed a retrospective study from January 2007 to December 2014. The patients are followed at the Department of Dermatology, Hospital Das Clínicas da Faculdade de Medicina da Universidade de São Paulo, a tertiary hospital at São Paulo, Brazil. We reviewed the data of 282 biopsy-proven LCV cases with DIF performed. For the statistical analysis, we included only patients with positive DIF exclusively in vessel walls (235/282 patients). We planned to find a correlation between the DIF profiles of LCV patients and the epidemiology data, underlying causes and prognosis. Ages ranged from five to 87 years old (yo), median age of 45 and 191/282 (67.73 %) were female individuals. DIF analysis showed positivity in 70.21 % of the samples, and C3 was the most frequent immunoreactant. Immunoglobulin A (IgA) deposition at the blood vessel wall was related to age and absence of autoimmune/inflammatory diseases. Immunoglobulin M (IgM) deposition at the blood vessel wall was related to females, autoimmune/inflammatory disorders, C3 and C4 consumption and antinuclear antibody and anti-SSA/anti-SSB positivity. Immunoglobulin G (IgG) deposition at the blood vessel wall was associated with age and positive ANCA; finally, C3 deposition at the blood vessel wall was associated with hematuria and renal involvement. Systemic involvement was present in 12.5 % cases of LCV patients. C3 deposits, the most frequent finding of this study, were related to renal involvement; IgA deposits to absence of autoimmune or inflammatory diseases; IgM deposition to the presence of autoimmune or inflammatory diseases and IgG deposits were associated with positive ANCA. DIF seems to be an important method to establish the

  3. Detecting multiple DNA human profile from a mosquito blood meal.

    Science.gov (United States)

    Rabêlo, K C N; Albuquerque, C M R; Tavares, V B; Santos, S M; Souza, C A; Oliveira, T C; Moura, R R; Brandão, L A C; Crovella, S

    2016-08-26

    Criminal traces commonly found at crime scenes may present mixtures from two or more individuals. The scene of the crime is important for the collection of various types of traces in order to find the perpetrator of the crime. Thus, we propose that hematophagous mosquitoes found at crime scenes can be used to perform genetic testing of human blood and aid in suspect investigation. The aim of the study was to obtain a single Aedes aegypti mosquito profile from a human DNA mixture containing genetic materials of four individuals. We also determined the effect of blood acquisition time by setting time intervals of 24, 48, and 72 h after the blood meal. STR loci and amelogenin were analyzed, and the results showed that human DNA profiles could be obtained from hematophagous mosquitos at 24 h following the blood meal. It is possible that hematophagous mosquitoes can be used as biological remains at the scene of the crime, and can be used to detect human DNA profiles of up to four individuals.

  4. Chagas Parasite Detection in Blood Images Using AdaBoost

    Directory of Open Access Journals (Sweden)

    Víctor Uc-Cetina

    2015-01-01

    Full Text Available The Chagas disease is a potentially life-threatening illness caused by the protozoan parasite, Trypanosoma cruzi. Visual detection of such parasite through microscopic inspection is a tedious and time-consuming task. In this paper, we provide an AdaBoost learning solution to the task of Chagas parasite detection in blood images. We give details of the algorithm and our experimental setup. With this method, we get 100% and 93.25% of sensitivity and specificity, respectively. A ROC comparison with the method most commonly used for the detection of malaria parasites based on support vector machines (SVM is also provided. Our experimental work shows mainly two things: (1 Chagas parasites can be detected automatically using machine learning methods with high accuracy and (2 AdaBoost + SVM provides better overall detection performance than AdaBoost or SVMs alone. Such results are the best ones known so far for the problem of automatic detection of Chagas parasites through the use of machine learning, computer vision, and image processing methods.

  5. 3D-black-blood 3T-MRI for the diagnosis of thoracic large vessel vasculitis: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Treitl, Karla Maria; Saam, Tobias [Institute for Clinical Radiology, LMU Munich, Munich (Germany); German Center for Cardiovascular Disease Research (DZHK e.V.), Munich (Germany); Maurus, Stefan; Sommer, Nora Narvina; Coppenrath, Eva; Treitl, Marcus [Institute for Clinical Radiology, LMU Munich, Munich (Germany); Kooijman-Kurfuerst, Hendrik [Philips Healthcare, Hamburg (Germany); Czihal, Michael; Hoffmann, Ulrich [LMU Munich, Division of Vascular Medicine, Medical Clinic and Policlinic IV, Munich (Germany); Dechant, Claudia; Schulze-Koops, Hendrik [LMU Munich, Division of Rheumatology and Clinical Immunology, Medical Clinic and Policlinic IV, Munich (Germany)

    2017-05-15

    To evaluate the feasibility of T1w-3D black-blood turbo spin echo (TSE) sequence with variable flip angles for the diagnosis of thoracic large vessel vasculitis (LVV). Thirty-five patients with LVV, diagnosed according to the current standard of reference, and 35 controls were imaged at 3.0T using 1.2 x 1.3 x 2.0 mm{sup 3} fat-suppressed, T1w-3D, modified Volumetric Isotropic TSE Acquisition (mVISTA) pre- and post-contrast. Applying a navigator and peripheral pulse unit triggering (PPU), the total scan time was 10-12 min. Thoracic aorta and subclavian and pulmonary arteries were evaluated for image quality (IQ), flow artefact intensity, diagnostic confidence, concentric wall thickening and contrast enhancement (CWT, CCE) using a 4-point scale. IQ was good in all examinations (3.25 ± 0.72) and good to excellent in 342 of 408 evaluated segments (83.8 %), while 84.1 % showed no or minor flow artefacts. The interobserver reproducibility for the identification of CCE and CWT was 0.969 and 0.971 (p < 0.001) with an average diagnostic confidence of 3.47 ± 0.64. CCE and CWT were strongly correlated (Cohen's k = 0.87; P < 0.001) and significantly more frequent in the LVV-group (52.8 % vs. 1.0 %; 59.8 % vs. 2.4 %; P < 0.001). Navigated fat-suppressed T1w-3D black-blood MRI with PPU-triggering allows diagnosis of thoracic LVV. (orig.)

  6. The Sustained Delivery of Resveratrol or a Defined Grape Powder Inhibits New Blood Vessel Formation in a Mouse Model of Choroidal Neovascularization

    Directory of Open Access Journals (Sweden)

    Mozhgan Rezaie Kanavi

    2014-10-01

    Full Text Available The objective of this study was to determine whether resveratrol or a defined, reconstituted grape powder can attenuate the formation of new blood vessels in a mouse model of choroidal neovascularization (CNV. To accomplish this objective, C57BL/6J mice were randomized into control or treatment groups which received either resveratrol or grape powder by daily oral gavage, resveratrol or grape powder delivered ad libitum through the drinking water, or resveratrol by slow release via implanted osmotic pumps. A laser was used to rupture Bruch’s membrane to induce CNV which was then detected in sclerochoroidal eyecups stained with antibodies against intercellular adhesion molecule-2. CNV area was measured using fluorescence microscopy and Image J software. Ad libitum delivery of both resveratrol and grape powder was shown to significantly reduce the extent of CNV by 68% and 57%, respectively. Parallel experiments conducted in vitro demonstrated that resveratrol activates p53 and inactivates Akt/protein kinase B in choroidal endothelial cells, contributing to its anti-proliferative and anti-migratory properties. In addition resveratrol was shown to inhibit the formation of endothelial cell networks, augmenting its overall anti-angiogenic effects. The non-toxic nature of resveratrol makes it an especially attractive candidate for the prevention and/or treatment of CNV.

  7. Placental mesenchymal stromal cells derived from blood vessels or avascular tissues: what is the better choice to support endothelial cell function?

    Science.gov (United States)

    König, Julia; Weiss, Gregor; Rossi, Daniele; Wankhammer, Karin; Reinisch, Andreas; Kinzer, Manuela; Huppertz, Berthold; Pfeiffer, Dagmar; Parolini, Ornella; Lang, Ingrid

    2015-01-01

    Mesenchymal stromal cells (MSCs) are promising tools for therapeutic revascularization of ischemic tissues and for support of vessel formation in engineered tissue constructs. Recently, we could show that avascular-derived MSCs from placental amnion release soluble factors that exhibit survival-enhancing effects on endothelial cells (ECs). We hypothesize that MSCs derived from placental blood vessels might have even more potent angiogenic effects. Therefore, we isolated and characterized MSCs from placental chorionic blood vessels (bv-MSCs) and tested their angiogenic potential in comparison to amnion-derived avascular MSCs (av-MSCs). bv-MSCs express a very similar surface marker profile compared with av-MSCs and could be differentiated toward the adipogenic and osteogenic lineages. bv-MSCs exert immunosuppressive properties on peripheral blood mononuclear cells, suggesting that they are suitable for cell transplantation settings. Conditioned medium (Cdm) from av-MSCs and bv-MSCs significantly enhanced EC viability, whereas only Cdm from bv-MSCs significantly increased EC migration and network formation (Matrigel assay). Angiogenesis array analysis of av- and bv-MSC-Cdm revealed a similar secretion pattern of angiogenic factors, including angiogenin, interleukins-6 and -8, and tissue inhibitors of matrix metalloproteinase-1 and 2. Enzyme-linked immunosorbent assay analysis showed that, in contrast to av-MSCs, bv-MSCs secreted vascular endothelial growth factor. In direct coculture with bv-MSCs, ECs showed a significantly increased formation of vessel-like structures compared with av-MSCs. With regard to therapeutic treatment, bv-MSCs and particularly their Cdm might be valuable to stimulate angiogenesis especially in ischemic tissues. av-MSCs and their Cdm could be beneficial in conditions when it is required to promote the survival and stabilization of blood vessels without the risk of unmeant angiogenesis.

  8. Direct testing of blood cultures for detection of streptococcal antigens.

    Science.gov (United States)

    Wetkowski, M A; Peterson, E M; de la Maza, L M

    1982-07-01

    A direct, rapid, and simple method for the detection of streptococcal antigens of Lancefield groups A, B, C, D, and G from blood cultures was developed by using a coagglutination test. Fifty-five clinical specimens and 117 simulated blood cultures containing gram-positive cocci were tested. Out of 6,261 clinical blood cultures screened, 55 cultures from 53 patients were positive, with organisms resembling streptococci, by Gram stain. Of these cultures, 78% (43 of 55) were pure cultures of streptococci, and 22% (12 of 55) were mixed with at least one other organism. Of the 43 pure cultures only, correct reactions were obtained (grouping correctly or giving no cross-reactions, or both) with 86% (37 of 43) of the isolates, 12% (5 of 43) exhibited cross-reactions, and 2% (1 of 43) gave false-negative reactions. All of the cross-reacting isolates were Streptococcus pneumoniae, which reacted with the group C reagent, and the false-negative reaction occurred with a Streptococcus bovis isolate. However, by using a direct modified bile solubility test, the correct identification of the S. pneumoniae isolates was obtained. Therefore, by using the modified bile solubility test in conjunction with the direct grouping method, 98% (42 of 43) of the isolates in pure culture could be identified accurately and rapidly after the detection of a positive Gram stain. Correct grouping reactions were obtained with 83% (10 of 12) of the mixed blood cultures, and false-negative results occurred with 17% (2 of 12) of them. Both cultures contained an enterococcus and a gram-negative rod. Of the 117 simulated blood cultures, there was only one incorrect grouping reaction; this occurred with an S. bovis isolate that cross-reacted with the group C reagent. The direct grouping reaction was positive when blood cultures contained a minimum of 1 x 10(8) to 8 x 10(8) colony-forming units per ml. In general, this procedure provided information on the identification of the organism 24 h earlier than

  9. A method for increasing the homogeneity of the temperature distribution during magnetic fluid hyperthermia with a Fe-Cr-Nb-B alloy in the presence of blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yundong [College of Physics and Information Engineering, Fuzhou University, Fuzhou 350116 (China); Flesch, Rodolfo C.C. [Departamento de Automação e Sistemas, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Jin, Tao, E-mail: jintly@fzu.edu.cn [College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350116 (China)

    2017-06-15

    Highlights: • The effects of blood vessels on temperature field distribution are investigated. • The critical thermal energy of hyperthermia is computed by the Finite Element Analysis. • A treatment method is proposed by using the MNPs with low Curie temperature. • The cooling effects due to the blood flow can be controlled. - Abstract: Magnetic hyperthermia ablates tumor cells by absorbing the thermal energy from magnetic nanoparticles (MNPs) under an external alternating magnetic field. The blood vessels (BVs) within tumor region can generally reduce treatment effectiveness due to the cooling effect of blood flow. This paper aims to investigate the cooling effect of BVs on the temperature field of malignant tumor regions using a complex geometric model and numerical simulation. For deriving the model, the Navier-Stokes equation for blood flow is combined with Pennes bio-heat transfer equation for human tissue. The effects on treatment temperature caused by two different BV distributions inside a mammary tumor are analyzed through numerical simulation under different conditions of flow rate considering a Fe-Cr-Nb-B alloy, which has low Curie temperature ranging from 42 °C to 45 °C. Numerical results show that the multi-vessel system has more obvious cooling effects than the single vessel one on the temperature field distribution for hyperthermia. Besides, simulation results show that the temperature field within tumor area can also be influenced by the velocity and diameter of BVs. To minimize the cooling effect, this article proposes a treatment method based on the increase of the thermal energy provided to MNPs associated with the adoption of low Curie temperature particles recently reported in literature. Results demonstrate that this approach noticeably improves the uniformity of the temperature field, and shortens the treatment time in a Fe-Cr-Nb-B system, thus reducing the side effects to the patient.

  10. DETECTION OF BIOFILM PRODUCTION IN BLOOD CULTURE ISOLATES OF STAPHYLOCOCCI

    Directory of Open Access Journals (Sweden)

    Gupta Puja, Gupta Pratima, Mittal Garima, Agarwal RK, Goyal Rohit

    2015-01-01

    Full Text Available Background: Biofilm producing bacteria which are inherently resistant to antibiotics and disinfectants are widely associated with implant associated infections. Staphylococcus is the most commonly associated pathogens with bloodstream infection. Aims: The current study was conducted to detect biofilm production in Staphylococci isolated from blood culture specimens. Materials and Methods: 70 clinically significant staphylococcal isolates from blood culture were screened for biofilm production by Tissue culture plate (TCP method, Tube method (TM and Congo red agar (CRA method and their antibiotic susceptibility profile was studied. Results: 59 out of 70 staphylococcal isolates were positive by TCP, out of these 21.4% staphylococci were high biofilm producers, 62.8% staphylococci were moderate biofilm producers and 15.8% were non-biofilm producers. Maximum resistance was observed in biofilm producers to cotrimoxazole (74.5% and erythromycin (62.7% and none were resistant to vancomycin and linezolid. Out of total 59 biofilm producers, 20.3 % (12 were methicillin resistant and all these were S. aureus isolates. 19% (1 out of total 11 biofilm non-producers were methicillin resistant. Conclusion: Biofilm production was seen to be a major virulence factor in most of the staphylococcal isolates obtained from patients with signs and symptoms of septicaemia. S. aureus was found to be the major pathogen and timely detection of biofilm producing phenotype should be carried out using a simple and reproducible method, TCP which is both qualitative and quantitative.

  11. Dilated thin-walled blood and lymphatic vessels in human endometrium: a potential role for VEGF-D in progestin-induced break-through bleeding.

    Directory of Open Access Journals (Sweden)

    Jacqueline F Donoghue

    Full Text Available Progestins provide safe, effective and cheap options for contraception as well as the treatment of a variety of gynaecological disorders. Episodes of irregular endometrial bleeding or breakthrough bleeding (BTB are a major unwanted side effect of progestin treatment, such that BTB is the leading cause for discontinued use of an otherwise effective and popular medication. The cellular mechanisms leading to BTB are poorly understood. In this study, we make the novel finding that the large, dilated, thin walled vessels characteristic of human progestin-treated endometrium include both blood and lymphatic vessels. Increased blood and lymphatic vessel diameter are features of VEGF-D action in other tissues and we show by immunolocalisation and Western blotting that stromal cell decidualisation results in a significant increase in VEGF-D protein production, particularly of the proteolytically processed 21 kD form. Using a NOD/scid mouse model with xenografted human endometrium we were able to show that progestin treatment causes decidualisation, VEGF-D production and endometrial vessel dilation. Our results lead to a novel hypothesis to explain BTB, with stromal cell decidualisation rather than progestin treatment per se being the proposed causative event, and VEGF-D being the proposed effector agent.

  12. Gene expression in peripheral blood differs after cardioembolic compared with large-vessel atherosclerotic stroke: biomarkers for the etiology of ischemic stroke.

    Science.gov (United States)

    Xu, Huichun; Tang, Yang; Liu, Da-Zhi; Ran, Ruiqiong; Ander, Bradley P; Apperson, Michelle; Liu, Xin She; Khoury, Jane C; Gregg, Jeffrey P; Pancioli, Arthur; Jauch, Edward C; Wagner, Kenneth R; Verro, Piero; Broderick, Joseph P; Sharp, Frank R

    2008-07-01

    There are no biomarkers that differentiate cardioembolic from large-vessel atherosclerotic stroke, although the treatments differ for each and approximately 30% of strokes and transient ischemic attacks have undetermined etiologies using current clinical criteria. We aimed to define gene expression profiles in blood that differentiate cardioembolic from large-vessel atherosclerotic stroke. Peripheral blood samples were obtained from healthy controls and acute ischemic stroke patients (genes differ at least 1.5-fold between them, and a minimum number of 23 genes differentiate the two types of stroke with at least 95.2% specificity and 95.2% sensitivity for each. Genes regulated in large-vessel atherosclerotic stroke are expressed in platelets and monocytes and modulate hemostasis. Genes regulated in cardioembolic stroke are expressed in neutrophils and modulate immune responses to infectious stimuli. This new method can be used to predict whether a stroke of unknown etiology was because of cardioembolism or large-vessel atherosclerosis that would lead to different therapy. These results have wide ranging implications for similar disorders.

  13. Application of optical coherence tomography for in vivo monitoring of the meningeal lymphatic vessels during opening of blood-brain barrier: mechanisms of brain clearing

    Science.gov (United States)

    Semyachkina-Glushkovskaya, Oxana; Abdurashitov, Arkady; Dubrovsky, Alexander; Bragin, Denis; Bragina, Olga; Shushunova, Nataliya; Maslyakova, Galina; Navolokin, Nikita; Bucharskaya, Alla; Tuchin, Valery; Kurths, Juergen; Shirokov, Alexander

    2017-12-01

    The meningeal lymphatic vessels were discovered 2 years ago as the drainage system involved in the mechanisms underlying the clearance of waste products from the brain. The blood-brain barrier (BBB) is a gatekeeper that strongly controls the movement of different molecules from the blood into the brain. We know the scenarios during the opening of the BBB, but there is extremely limited information on how the brain clears the substances that cross the BBB. Here, using the model of sound-induced opening of the BBB, we clearly show how the brain clears dextran after it crosses the BBB via the meningeal lymphatic vessels. We first demonstrate successful application of optical coherence tomography (OCT) for imaging of the lymphatic vessels in the meninges after opening of the BBB, which might be a new useful strategy for noninvasive analysis of lymphatic drainage in daily clinical practice. Also, we give information about the depth and size of the meningeal lymphatic vessels in mice. These new fundamental data with the applied focus on the OCT shed light on the mechanisms of brain clearance and the role of lymphatic drainage in these processes that could serve as an informative platform for a development of therapy and diagnostics of diseases associated with injuries of the BBB such as stroke, brain trauma, glioma, depression, or Alzheimer disease.

  14. Quantitation of dissolved gas content in emulsions and in blood using mass spectrometric detection

    Science.gov (United States)

    Grimley, Everett; Turner, Nicole; Newell, Clayton; Simpkins, Cuthbert; Rodriguez, Juan

    2011-01-01

    Quantitation of dissolved gases in blood or in other biological media is essential for understanding the dynamics of metabolic processes. Current detection techniques, while enabling rapid and convenient assessment of dissolved gases, provide only direct information on the partial pressure of gases dissolved in the aqueous fraction of the fluid. The more relevant quantity known as gas content, which refers to the total amount of the gas in all fractions of the sample, can be inferred from those partial pressures, but only indirectly through mathematical modeling. Here we describe a simple mass spectrometric technique for rapid and direct quantitation of gas content for a wide range of gases. The technique is based on a mass spectrometer detector that continuously monitors gases that are rapidly extracted from samples injected into a purge vessel. The accuracy and sample processing speed of the system is demonstrated with experiments that reproduce within minutes literature values for the solubility of various gases in water. The capability of the technique is further demonstrated through accurate determination of O2 content in a lipid emulsion and in whole blood, using as little as 20 μL of sample. The approach to gas content quantitation described here should greatly expand the range of animals and conditions that may be used in studies of metabolic gas exchange, and facilitate the development of artificial oxygen carriers and resuscitation fluids. PMID:21497566

  15. Short-Term Blood Pressure Variability Relates to the Presence of Subclinical Brain Small Vessel Disease in Primary Hypertension.

    Science.gov (United States)

    Filomena, Josefina; Riba-Llena, Iolanda; Vinyoles, Ernest; Tovar, José L; Mundet, Xavier; Castañé, Xavier; Vilar, Andrea; López-Rueda, Antonio; Jiménez-Baladó, Joan; Cartanyà, Anna; Montaner, Joan; Delgado, Pilar

    2015-09-01

    Blood pressure (BP) variability is associated with stroke risk, but less is known about subclinical cerebral small vessel disease (CSVD). We aimed to determine whether CSVD relates to short-term BP variability independently of BP levels and also, whether they improve CSVD discrimination beyond clinical variables and office BP levels. This was a cohort study on asymptomatic hypertensives who underwent brain magnetic resonance imaging and 24-hour ambulatory BP monitoring. Office and average 24-hour, daytime and nighttime BP levels, and several metrics of BP variability (SD, weighted SD, coefficient of variation, and average real variability [ARV]) were calculated. Definition of CSVD was based on the presence of lacunar infarcts and white matter hyperintensity grades. Multivariate analysis and integrated discrimination improvement were performed to assess whether BP variability and levels were independently associated with CSVD and improved its discrimination. Four hundred eighty-seven individuals participated (median age, 64; 47% women). CSVD was identified in 18.9%, related to age, male sex, diabetes mellitus, use of treatment, ambulatory BP monitoring-defined BP levels, and ARV of systolic BP at any period. The highest prevalence (33.7%) was found in subjects with both 24-hour BP levels and ARV elevated. BP levels at any period and ARV (24 hours and nocturnal) emerged as independent predictors of CSVD, and discrimination was incrementally improved although not to a clinically significant extent (integrated discrimination improvement, 5.31%, 5.17% to 5.4%). Ambulatory BP monitoring-defined BP levels and ARV of systolic BP relate to subclinical CSVD in hypertensive individuals. © 2015 American Heart Association, Inc.

  16. P2X7R antagonism after subfailure overstretch injury of blood vessels reverses vasomotor dysfunction and prevents apoptosis.

    Science.gov (United States)

    Luo, Weifeng; Feldman, Daniel; McCallister, Reid; Brophy, Colleen; Cheung-Flynn, Joyce

    2017-12-01

    Human saphenous vein (HSV) is harvested and prepared prior to implantation as an arterial bypass graft. Injury and the response to injury from surgical harvest and preparation trigger cascades of molecular events and contribute to graft remodeling and intimal hyperplasia. Apoptosis is an early response after implantation that contributes the development of neointimal lesions. Here, we showed that surgical harvest and preparation of HSV leads to vasomotor dysfunction, increased apoptosis and downregulation of the phosphorylation of the anti-apoptotic protein, Niban. A model of subfailure overstretch injury in rat aorta (RA) was used to demonstrate impaired vasomotor function, increased extracellular ATP (eATP) release, and increased apoptosis following pathological vascular injury. The subfailure overstretch injury was associated with activation of p38 MAPK stress pathway and decreases in the phosphorylation of the anti-apoptotic protein Niban. Treatment of RA after overstretch injury with antagonists to purinergic P2X7 receptor (P2X7R) antagonists or P2X7R/pannexin (PanX1) complex, but not PanX1 alone, restored vasomotor function. Inhibitors to P2X7R and PanX1 reduced stretch-induced eATP release. P2X7R/PanX1 antagonism led to decrease in p38 MAPK phosphorylation, restoration of Niban phosphorylation and increases in the phosphorylation of the anti-apoptotic protein Akt in RA and reduced TNFα-stimulated caspase 3/7 activity in cultured rat vascular smooth muscle cells. In conclusion, inhibition of P2X7R after overstretch injury restored vasomotor function and inhibited apoptosis. Treatment with P2X7R/PanX1 complex inhibitors after harvest and preparation injury of blood vessels used for bypass conduits may prevent the subsequent response to injury that lead to apoptosis and represents a novel therapeutic approach to prevent graft failure.

  17. Accelerated whole brain intracranial vessel wall imaging using black blood fast spin echo with compressed sensing (CS-SPACE).

    Science.gov (United States)

    Zhu, Chengcheng; Tian, Bing; Chen, Luguang; Eisenmenger, Laura; Raithel, Esther; Forman, Christoph; Ahn, Sinyeob; Laub, Gerhard; Liu, Qi; Lu, Jianping; Liu, Jing; Hess, Christopher; Saloner, David

    2017-12-05

    Develop and optimize an accelerated, high-resolution (0.5 mm isotropic) 3D black blood MRI technique to reduce scan time for whole-brain intracranial vessel wall imaging. A 3D accelerated T 1 -weighted fast-spin-echo prototype sequence using compressed sensing (CS-SPACE) was developed at 3T. Both the acquisition [echo train length (ETL), under-sampling factor] and reconstruction parameters (regularization parameter, number of iterations) were first optimized in 5 healthy volunteers. Ten patients with a variety of intracranial vascular disease presentations (aneurysm, atherosclerosis, dissection, vasculitis) were imaged with SPACE and optimized CS-SPACE, pre and post Gd contrast. Lumen/wall area, wall-to-lumen contrast ratio (CR), enhancement ratio (ER), sharpness, and qualitative scores (1-4) by two radiologists were recorded. The optimized CS-SPACE protocol has ETL 60, 20% k-space under-sampling, 0.002 regularization factor with 20 iterations. In patient studies, CS-SPACE and conventional SPACE had comparable image scores both pre- (3.35 ± 0.85 vs. 3.54 ± 0.65, p = 0.13) and post-contrast (3.72 ± 0.58 vs. 3.53 ± 0.57, p = 0.15), but the CS-SPACE acquisition was 37% faster (6:48 vs. 10:50). CS-SPACE agreed with SPACE for lumen/wall area, ER measurements and sharpness, but marginally reduced the CR. In the evaluation of intracranial vascular disease, CS-SPACE provides a substantial reduction in scan time compared to conventional T 1 -weighted SPACE while maintaining good image quality.

  18. Role of Nox inhibitors plumbagin, ML090 and gp91ds-tat peptide on homocysteine thiolactone induced blood vessel dysfunction.

    Science.gov (United States)

    Smith, Renee M; Kruzliak, Peter; Adamcikova, Zuzana; Zulli, Anthony

    2015-08-01

    Antioxidants have not reduced the burden of cardiovascular disease, and current evidence suggests a beneficial role of oxidative stress, via NADPH oxidase (Nox) upregulation, in endothelial function. Homocysteine thiolactone (HcyT) induces blood vessel dysfunction and this correlates with increased vascular oxidative stress. This study aimed to determine if pharmacological inhibition of Nox could impair HcyT induced blood vessel dysfunction. Abdominal aorta were excised from New Zealand White rabbits (n = 6), cut into rings and sequentially mounted in organ baths. Rings were preincubated with 0.55 μmol/L homocysteine thiolactone for 1 h, or combinations of putative Nox inhibitors (plumbagin for Nox4, gp91ds-tat for Nox2, and ML090 for Nox1), 30 min prior to the addition of HcyT, followed by a dose response curve to acetylcholine on phenylephrine preconstricted rings. Plumbagin, ML090 + gp91ds-tat and HcyT reduced responses to acetylcholine, and Plumbagin + Hcyt caused constriction to acetylcholine, which was normalised to plumbagin by ML090. Plumbagin + ML090 or plumbagin + gp91ds-tat completely impaired the effect of acetylcholine. ML090 inhibited the effect of HcyT on reduced response to acetylcholine, whereas gp91ds-tat had no effect. This study concludes that inhibition of Nox1 prevents, whereas inhibition of Nox4 worsens, acetylcholine induced blood vessel relaxation caused by HcyT, while Nox2 inhibition has no effect. However combinations of Nox inhibitors worsen acetylcholine induced blood vessel relaxation. These results suggest that there is cross-talk between Nox isoforms during physiological and pathophysiological processes. © 2015 Wiley Publishing Asia Pty Ltd.

  19. Nanobubbles Form at Active Hydrophobic Spots on the Luminal Aspect of Blood Vessels: Consequences for Decompression Illness in Diving and Possible Implications for Autoimmune Disease—An Overview

    Directory of Open Access Journals (Sweden)

    Ran Arieli

    2017-08-01

    Full Text Available Decompression illness (DCI occurs following a reduction in ambient pressure. Decompression bubbles can expand and develop only from pre-existing gas micronuclei. The different hypotheses hitherto proposed regarding the nucleation and stabilization of gas micronuclei have never been validated. It is known that nanobubbles form spontaneously when a smooth hydrophobic surface is submerged in water containing dissolved gas. These nanobubbles may be the long sought-after gas micronuclei underlying decompression bubbles and DCI. We exposed hydrophobic and hydrophilic silicon wafers under water to hyperbaric pressure. After decompression, bubbles appeared on the hydrophobic but not the hydrophilic wafers. In a further series of experiments, we placed large ovine blood vessels in a cooled high pressure chamber at 1,000 kPa for about 20 h. Bubbles evolved at definite spots in all the types of blood vessels. These bubble-producing spots stained positive for lipids, and were henceforth termed “active hydrophobic spots” (AHS. The lung surfactant dipalmitoylphosphatidylcholine (DPPC, was found both in the plasma of the sheep and at the AHS. Bubbles detached from the blood vessel in pulsatile flow after reaching a mean diameter of ~1.0 mm. Bubble expansion was bi-phasic—a slow initiation phase which peaked 45 min after decompression, followed by fast diffusion-controlled growth. Many features of decompression from diving correlate with this finding of AHS on the blood vessels. (1 Variability between bubblers and non-bubblers. (2 An age-related effect and adaptation. (3 The increased risk of DCI on a second dive. (4 Symptoms of neurologic decompression sickness. (5 Preconditioning before a dive. (6 A bi-phasic mechanism of bubble expansion. (7 Increased bubble formation with depth. (8 Endothelial injury. (9 The presence of endothelial microparticles. Finally, constant contact between nanobubbles and plasma may result in distortion of proteins and their

  20. High blood pressure - infants

    Science.gov (United States)

    Hypertension - infants ... and blood vessels The health of the kidneys High blood pressure in infants may be due to kidney or ... blood vessel of the kidney) In newborn babies, high blood pressure is often caused by a blood clot in ...

  1. Blood Vessel Formation and Bone Regeneration Potential of the Stromal Vascular Fraction Seeded on a Calcium Phosphate Scaffold in the Human Maxillary Sinus Floor Elevation Model

    Directory of Open Access Journals (Sweden)

    Elisabet Farré-Guasch

    2018-01-01

    Full Text Available Bone substitutes are used as alternatives for autologous bone grafts in patients undergoing maxillary sinus floor elevation (MSFE for dental implant placement. However, bone substitutes lack osteoinductive and angiogenic potential. Addition of adipose stem cells (ASCs may stimulate osteogenesis and osteoinduction, as well as angiogenesis. We aimed to evaluate the vascularization in relation to bone formation potential of the ASC-containing stromal vascular fraction (SVF of adipose tissue, seeded on two types of calcium phosphate carriers, within the human MSFE model, in a phase I study. Autologous SVF was obtained from ten patients and seeded on β-tricalcium phosphate (n = 5 or biphasic calcium phosphate carriers (n = 5, and used for MSFE in a one-step surgical procedure. After six months, biopsies were obtained during dental implant placement, and the quantification of the number of blood vessels was performed using histomorphometric analysis and immunohistochemical stainings for blood vessel markers, i.e., CD34 and alpha-smooth muscle actin. Bone percentages seemed to correlate with blood vessel formation and were higher in study versus control biopsies in the cranial area, in particular in β-tricalcium phosphate-treated patients. This study shows the safety, feasibility, and efficiency of the use of ASCs in the human MSFE, and indicates a pro-angiogenic effect of SVF.

  2. Comparative survival study of glial cells and cells composing walls of blood vessels in crustacean ventral nerve cord after photodynamic treatment

    Science.gov (United States)

    Kolosov, Mikhail S.; Shubina, Elena

    2015-03-01

    Photodynamic therapy is a prospective treatment modality of brain cancers. It is of importance to have information about relative survival rate of different cell types in nerve tissue during photodynamic treatment. Particularly, for development of sparing strategy of the photodynamic therapy of brain tumors, which pursuits both total elimination of malignant cells, which are usually of glial origin, and, at the same time, preservation of normal blood circulation as well as normal glial cells in the brain. The aim of this work was to carry out comparative survival study of glial cells and cells composing walls of blood vessels after photodynamic treatment, using simple model object - ventral nerve cord of crustacean.

  3. Blood detection in wireless capsule endoscopy using expectation maximization clustering

    Science.gov (United States)

    Hwang, Sae; Oh, JungHwan; Cox, Jay; Tang, Shou Jiang; Tibbals, Harry F.

    2006-03-01

    Wireless Capsule Endoscopy (WCE) is a relatively new technology (FDA approved in 2002) allowing doctors to view most of the small intestine. Other endoscopies such as colonoscopy, upper gastrointestinal endoscopy, push enteroscopy, and intraoperative enteroscopy could be used to visualize up to the stomach, duodenum, colon, and terminal ileum, but there existed no method to view most of the small intestine without surgery. With the miniaturization of wireless and camera technologies came the ability to view the entire gestational track with little effort. A tiny disposable video capsule is swallowed, transmitting two images per second to a small data receiver worn by the patient on a belt. During an approximately 8-hour course, over 55,000 images are recorded to a worn device and then downloaded to a computer for later examination. Typically, a medical clinician spends more than two hours to analyze a WCE video. Research has been attempted to automatically find abnormal regions (especially bleeding) to reduce the time needed to analyze the videos. The manufacturers also provide the software tool to detect the bleeding called Suspected Blood Indicator (SBI), but its accuracy is not high enough to replace human examination. It was reported that the sensitivity and the specificity of SBI were about 72% and 85%, respectively. To address this problem, we propose a technique to detect the bleeding regions automatically utilizing the Expectation Maximization (EM) clustering algorithm. Our experimental results indicate that the proposed bleeding detection method achieves 92% and 98% of sensitivity and specificity, respectively.

  4. Effects of High-sugar and High-fat Diet on Fat Deposition and Blood Vessel Wall on Sprague Dawley Rats Liver

    Directory of Open Access Journals (Sweden)

    Vera Citra Setiawan Hoei

    2013-11-01

    Full Text Available People nowadays tend to consume more fast food and sweetened beverages. These foods usually contain high amount sugar and fat that have effects on the body including liver.This study was conducted to explore the effects of extensive intake of sugar and fat on blood glucose and  cholesterol level as well as changes in liver. Research was conducted with experimental method using 20 Sprague Dawley rats which were divided into 4 groups; 2 controls and 2 treatments. Rats were given 5 ml sugar or lard alternatively every 2 consecutive days for 1-month and 2-month respectively. Data was retrieved include blood glucose and cholesterol level, fatty liver percentage and blood vessel thickening after intervention through HE staining. The results showed that both 1-month and 2-month intervention group has significant increase in blood glucose and cholesterol level. However, the enhancement of fatty liver percentage and number of thickened blood vessels (p<0.05 were only foundsignificant (p<0.05 in 1-month intervention group.  We concluded that high intake of sugar and fat within 1-monthintervention have significant effects on the rat body including liver. Nevertheless, it was not found significant in 2-months intervention. Further studies are still needed to analyze this incongruent result.Key words: high-sugar diet, high-fat diet, fatty liver, atherosclerosis 

  5. The dynamics of 24-hour ambulatory blood pressure monitoring parameters, subclinical damage and endothelial function of vessels in patients with arterial hypertension and chronic obstructive pulmonary disease treated with S-amlodipine, Nebivolol and Enala

    Directory of Open Access Journals (Sweden)

    O. G. Ivanko

    2017-02-01

    Full Text Available Aim of the research was to investigate additional prescription of S-amlodipine or Nebivolol to Enalapril treatment on the 24-h blood pressure monitoring (BPM parameters, subclinical damage and endothelial function of vessels, and to make of proposing of treatment of the arterial hypertension (AH and chronic obstructive pulmonary disease (COPD. Material and Methods. 95 patients (64 males and 31 females with AH II stage and COPD III stage in remission were observed. The average age was (54.7 ± 9.5 years. The 24-h BPM by devices “АВРМ-04” (“Meditech”, Hungary and “EBPM” (“Innomed”, Hungary was provided to all patients. Stiffness index of aorta (ASI was evaluated by Yu.M. Sirenko and G.D. Radchenko method (2009. Reactive hyperemia test was performed by D.S. Celermajer, K.E. Sorensen et al. method (1992. Computer spirography was made by “SpiroCom” (HAI-Medica, Ukraine. The serum level of endothelin -1 (ET 1 was detected by ELISA (“Peninsula Laboratories”, USA. Results. It was established, that additional prescription of S-amlodipine or Nebivolol to Enalapril and standard therapy of COPD during 6 month had strong antihypertensive effect, normalized 24-hours blood pressure profile, decreased blood pressure loading and subclinical damage indices, such as: pulse blood pressure, heart rate and ASI. Conclusion. Treatment of patients with AH and COPD should be differentiated. In case of prevalence of the clinical, laboratory and instrumental signs of broncho-obsctructive syndrome, presence of subclinical damages and elastic qualities of vessels and endothelial dysfunction in patients with AH and COPD S-amlodipine should be prescribed additionally to Enalapril and basic therapy of CODP. In case of AH and COPD with hypersympatheticotonia, sings of blood pressure loading, increase of pulse BP and tachycardia beta-blocker Nebivolol should be added to the treatment.

  6. [Impacts on carotid arterial vessel and blood flow in treatment of carotid atherosclerosis with acupuncture and moxibustion].

    Science.gov (United States)

    Zhang, Wen-Lai; Wang, Wei-Zhi

    2011-09-01

    To assess the impacts of acupuncture and moxibustion on carotid arterial vascular structure and blood flow parameters for the patients with carotid arteriosclerosis. Sixty-eight cases were randomized into an acupuncture-moxibustion group (35 cases) and a medication group (33 cases). In the acupuncture-moxibustion group, Renying (ST 9), Neiguan (PC 6), Zusanli (ST 36), etc. were selected, moxibustion was applied at Zusanli (ST 36). In the medication group, Enteric-coated aspirin was taken orally. The high-frequency ultrasonography was applied to detect common carotid artery (CCA), intima-media thickness (IMT), peak systolic velocity (PSV), end diastolic velocity (EDV), pulsatility index (PI) and resistance index (RI) before and after treatment for the comparative analysis. After treatment, in comparison between acupuncture-moxibustion group and medication group, CCA got bigger [(8.16 +/- 0.80) mm vs (7.69 +/- 0.61) mm, P Acupuncture and moxibustion provides a good efficacy on the improvement in carotid arteriosclerosis and blood flow in carotid artery, which contributes to the alleviation of ischemic cerebrovascular diseases and prevention from the occurrence and development of them.

  7. Face Liveness Detection Based on Skin Blood Flow Analysis

    Directory of Open Access Journals (Sweden)

    Shun-Yi Wang

    2017-12-01

    Full Text Available Face recognition systems have been widely adopted for user authentication in security systems due to their simplicity and effectiveness. However, spoofing attacks, including printed photos, displayed photos, and replayed video attacks, are critical challenges to authentication, and these spoofing attacks allow malicious invaders to gain access to the system. This paper proposes two novel features for face liveness detection systems to protect against printed photo attacks and replayed attacks for biometric authentication systems. The first feature obtains the texture difference between red and green channels of face images inspired by the observation that skin blood flow in the face has properties that enable distinction between live and spoofing face images. The second feature estimates the color distribution in the local regions of face images, instead of whole images, because image quality might be more discriminative in small areas of face images. These two features are concatenated together, along with a multi-scale local binary pattern feature, and a support vector machine classifier is trained to discriminate between live and spoofing face images. The experimental results show that the performance of the proposed method for face spoof detection is promising when compared with that of previously published methods. Furthermore, the proposed system can be implemented in real time, which is valuable for mobile applications.

  8. JOURNAL CLUB: Computer-Aided Detection of Lung Nodules on CT With a Computerized Pulmonary Vessel Suppressed Function.

    Science.gov (United States)

    Lo, ShihChung B; Freedman, Matthew T; Gillis, Laura B; White, Charles S; Mun, Seong K

    2018-03-01

    The purpose of this study is to evaluate radiologists' performance in detecting actionable nodules on chest CT when aided by a pulmonary vessel image-suppressed function and a computer-aided detection (CADe) system. A novel computerized pulmonary vessel image-suppressed function with a built-in CADe (VIS/CADe) system was developed to assist radiologists in interpreting thoracic CT images. Twelve radiologists participated in a comparative study without and with the VIS/CADe using 324 cases (involving 95 cancers and 83 benign nodules). The ratio of nodule-free cases to cases with nodules was 2:1 in the study. Localization ROC (LROC) methods were used for analysis. In a stand-alone test, the VIS/CADe system detected 89.5% and 82.0% of malignant nodules and all nodules no smaller than 5 mm, respectively. The false-positive rate per CT study was 0.58. For the reader study, the mean area under the LROC curve (LROCAUC) for the detection of lung cancer significantly increased from 0.633 when unaided by VIS/CADe to 0.773 when aided by VIS/CADe (p < 0.01). For the detection of all clinically actionable nodules, the mean LROC-AUC significantly increased from 0.584 when unaided by VIS/CADe to 0.692 when detection was aided by VIS/CADe (p < 0.01). Radiologists detected 80.0% of cancers with VIS/CADe versus 64.45% of cancers unaided (p < 0.01); specificity decreased from 89.9% to 84.4% (p < 0.01). Radiologist interpretation time significantly decreased by 26%. The VIS/CADe system significantly increased radiologists' detection of cancers and actionable nodules with somewhat lower specificity. With use of the VIS/CADe system, radiologists increased their interpretation speed by a factor of approximately one-fourth. Our study suggests that the technique has the potential to assist radiologists in the detection of additional actionable nodules on thoracic CT.

  9. Long-term detection of microchimaerism in peripheral blood after pretransplantation blood transfusion

    NARCIS (Netherlands)

    Vervoordeldonk, S. F.; Doumaid, K.; Remmerswaal, E. B.; ten Berge, I. J.; Wilmink, J. M.; de Waal, L. P.; Boog, C. J.

    1998-01-01

    Renal allograft survival is prolonged after pretransplantation blood transfusion. The aim of this study was to test retrospectively the development and persistence of microchimaerism after pretransplantation blood transfusion and to assess whether the type of blood transfusion (partially matched [=

  10. Effect of heat transfer on unsteady MHD flow of blood in a permeable vessel in the presence of non-uniform heat source

    Directory of Open Access Journals (Sweden)

    A. Sinha

    2016-09-01

    Full Text Available This paper presents a theoretical analysis of blood flow and heat transfer in a permeable vessel in the presence of an external magnetic field. The unsteadiness in the coupled flow and temperature fields is considered to be caused due to the time-dependent stretching velocity and the surface temperature of the vessel. The non-uniform heat source/sink effect on blood flow and heat transfer is taken into account. This study is of potential value in the clinical treatment of cardiovascular disorders accompanied by accelerated circulation. The problem is treated mathematically by reducing it to a system of coupled nonlinear differential equations, which have been solved by using similarity transformation and boundary layer approximation. The resulting nonlinear coupled ordinary differential equations are solved numerically by using an implicit finite difference scheme. Computational results are obtained for the velocity, temperature, the skin-friction coefficient and the rate of heat transfer in the vessel. The estimated results are compared with another analytical study reported earlier in scientific literatures. The present study reveals that the heat transfer rate is enhanced as the value of the unsteadiness parameter increases, but it reduces as the space-dependence parameter for heat source/sink increases.

  11. Mycobacterium tuberculosis bacteremia detected by the Isolator lysis-centrifugation blood culture system.

    OpenAIRE

    Kiehn, T E; Gold, J W; Brannon, P; Timberger, R J; Armstrong, D

    1985-01-01

    Mycobacterium tuberculosis was detected by the Isolator lysis-centrifugation blood culture system from the blood of a patient with tuberculosis of the breast. The organism also grew on conventional laboratory media inoculated with pleural fluid from the patient.

  12. Vessel Operating Units (Vessels)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains data for vessels that are greater than five net tons and have a current US Coast Guard documentation number. Beginning in1979, the NMFS...

  13. Assessment of flaw detection probability in the case of pressure vessel materials

    International Nuclear Information System (INIS)

    Riikonen, H.; Raussi, J.; Tiainen, O.J.A.

    1983-01-01

    Shaffer has presented a method for assessing flaw detection probability in pressure retaining components. In this case study the usefulness of Shaffer's method is examined using inspection data from a BWR- plant piping and mathematical fittings for size distributions of detected flaws. It was seen that the size distribution function has to fulfill many conditions to be useful for assessing the detection probability of flaws. The discovery of a proper Shaffer's ω function appears to be the key factor for the usefulness of the model

  14. Automated Manufacture of Damage Detecting, Self-Healing Composite Cryogenic Pressure Vessels, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — After successfully demonstrating the basic functionality of a damage-detecting, self-healing 'smart' material system in Phase I, Aurora and UMass Lowell aim to...

  15. A method for increasing the homogeneity of the temperature distribution during magnetic fluid hyperthermia with a Fe-Cr-Nb-B alloy in the presence of blood vessels

    Science.gov (United States)

    Tang, Yundong; Flesch, Rodolfo C. C.; Jin, Tao

    2017-06-01

    Magnetic hyperthermia ablates tumor cells by absorbing the thermal energy from magnetic nanoparticles (MNPs) under an external alternating magnetic field. The blood vessels (BVs) within tumor region can generally reduce treatment effectiveness due to the cooling effect of blood flow. This paper aims to investigate the cooling effect of BVs on the temperature field of malignant tumor regions using a complex geometric model and numerical simulation. For deriving the model, the Navier-Stokes equation for blood flow is combined with Pennes bio-heat transfer equation for human tissue. The effects on treatment temperature caused by two different BV distributions inside a mammary tumor are analyzed through numerical simulation under different conditions of flow rate considering a Fe-Cr-Nb-B alloy, which has low Curie temperature ranging from 42 °C to 45 °C. Numerical results show that the multi-vessel system has more obvious cooling effects than the single vessel one on the temperature field distribution for hyperthermia. Besides, simulation results show that the temperature field within tumor area can also be influenced by the velocity and diameter of BVs. To minimize the cooling effect, this article proposes a treatment method based on the increase of the thermal energy provided to MNPs associated with the adoption of low Curie temperature particles recently reported in literature. Results demonstrate that this approach noticeably improves the uniformity of the temperature field, and shortens the treatment time in a Fe-Cr-Nb-B system, thus reducing the side effects to the patient.

  16. A Comparison of Black-blood T2 Mapping Sequences for Carotid Vessel Wall Imaging at 3T: An Assessment of Accuracy and Repeatability.

    Science.gov (United States)

    Yuan, Jianmin; Patterson, Andrew J; Ruetten, Pascal P R; Reid, Scott A; Gillard, Jonathan H; Graves, Martin J

    2018-03-08

    This study is to compare the accuracy of four different black-blood T 2 mapping sequences in carotid vessel wall. Four different black-blood T 2 mapping sequences were developed and tested through phantom experiments and 17 healthy volunteers. The four sequences were: 1) double inversion-recovery (DIR) prepared 2D multi-echo spin-echo (MESE); 2) DIR-prepared 2D multi-echo fast spin-echo (MEFSE); 3) improved motion-sensitized driven-equilibrium (iMSDE) prepared 3D FSE and 4) iMSDE prepared 3D fast spoiled gradient echo (FSPGR). The concordance correlation coefficient and Bland-Altman statistics were used to compare the sequences with a gold-standard 2D MESE, without blood suppression in phantom studies. The volunteers were scanned twice to test the repeatability. Mean and standard deviation of vessel wall T 2 , signal-to-noise (SNR), the coefficient of variance and interclass coefficient (ICC) of the two scans were compared. The phantom study demonstrated that T 2 measurements had high concordance with respect to the gold-standard (all r values >0.9). In the volunteer study, the DIR 2D MEFSE had significantly higher T 2 values than the other three sequences (P 0.05). iMSDE 3D FSE had the highest SNR (P < 0.05) compared with the other three sequences. The 2D DIR MESE has the highest repeatability (ICC: 0.96, [95% CI: 0.88-0.99]). Although accurate T 2 measurements can be achieved in phantom by the four sequences, in vivo vessel wall T 2 quantification shows significant differences. The in vivo images can be influenced by multiple factors including black-blood preparation and acquisition method. Therefore, a careful choice of acquisition methods and analysis of the confounding factors are required for accurate in vivo carotid vessel wall T 2 measurements. From the settings in this study, the iMSDE prepared 3D FSE is preferred for the future volunteer/patient scans.

  17. The best of a BAD situation: Optimising an algorithm to match course resolution SAR vessel detections to sparse AIS data

    CSIR Research Space (South Africa)

    Meyer, Rory GV

    2017-07-01

    Full Text Available or shipping lanes. Different vessel classes can have different behaviours; cargo and tanker vessels tend to move in the most efficient manner between ports while tugs and fishing vessels move in more haphazard tracks while performing their tasks. Using a...

  18. FMCW radar system for detection and classification of small vessels in high sea state conditions

    NARCIS (Netherlands)

    Wasselin, J.-P.; Mazuel, S.; Itcia, E.; Huizing, A.G.; Theil, A.

    2012-01-01

    The ROCKWELL COLLINS France radar department is currently developing a FMCW radar system for the detection and the classification of small maritime targets in the frame of the SISMARIS, SARGOS & I2C projects. Several test campaigns have been conducted since 2009 to develop a sensor as well as an

  19. Vision-Based Corrosion Detection Assisted by a Micro-Aerial Vehicle in a Vessel Inspection Application

    Directory of Open Access Journals (Sweden)

    Alberto Ortiz

    2016-12-01

    Full Text Available Vessel maintenance requires periodic visual inspection of the hull in order to detect typical defective situations of steel structures such as, among others, coating breakdown and corrosion. These inspections are typically performed by well-trained surveyors at great cost because of the need for providing access means (e.g., scaffolding and/or cherry pickers that allow the inspector to be at arm’s reach from the structure under inspection. This paper describes a defect detection approach comprising a micro-aerial vehicle which is used to collect images from the surfaces under inspection, particularly focusing on remote areas where the surveyor has no visual access, and a coating breakdown/corrosion detector based on a three-layer feed-forward artificial neural network. As it is discussed in the paper, the success of the inspection process depends not only on the defect detection software but also on a number of assistance functions provided by the control architecture of the aerial platform, whose aim is to improve picture quality. Both aspects of the work are described along the different sections of the paper, as well as the classification performance attained.

  20. Comparison of algorithms for blood stain detection applied to forensic hyperspectral imagery

    Science.gov (United States)

    Yang, Jie; Messinger, David W.; Mathew, Jobin J.; Dube, Roger R.

    2016-05-01

    Blood stains are among the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Early detection of blood stains is particularly important since the blood reacts physically and chemically with air and materials over time. Accurate identification of blood remnants, including regions that might have been intentionally cleaned, is an important aspect of forensic investigation. Hyperspectral imaging might be a potential method to detect blood stains because it is non-contact and provides substantial spectral information that can be used to identify regions in a scene with trace amounts of blood. The potential complexity of scenes in which such vast violence occurs can be high when the range of scene material types and conditions containing blood stains at a crime scene are considered. Some stains are hard to detect by the unaided eye, especially if a conscious effort to clean the scene has occurred (we refer to these as "latent" blood stains). In this paper we present the initial results of a study of the use of hyperspectral imaging algorithms for blood detection in complex scenes. We describe a hyperspectral imaging system which generates images covering 400 nm - 700 nm visible range with a spectral resolution of 10 nm. Three image sets of 31 wavelength bands were generated using this camera for a simulated indoor crime scene in which blood stains were placed on a T-shirt and walls. To detect blood stains in the scene, Principal Component Analysis (PCA), Subspace Reed Xiaoli Detection (SRXD), and Topological Anomaly Detection (TAD) algorithms were used. Comparison of the three hyperspectral image analysis techniques shows that TAD is most suitable for detecting blood stains and discovering latent blood stains.

  1. Detection of Salmonella typhi by nested polymerase chain reaction in blood, urine, and stool samples

    NARCIS (Netherlands)

    Hatta, Mochammad; Smits, Henk L.

    2007-01-01

    A nested polymerase chain reaction (PCR) specific for Salmonella enterica serovar Typhi was used for the detection of the pathogen in blood, urine, and stool samples from 131 patients with clinical suspicion of typhoid fever. The sensitivity of blood culture, the PCRs with blood, urine, and feces,

  2. Diagnostic performance of computed tomography coronary angiography to detect and exclude left main and/or three-vessel coronary artery disease

    DEFF Research Database (Denmark)

    Dharampal, Anoeshka S; Papadopoulou, Stella L; Rossi, Alexia

    2013-01-01

    To determine the diagnostic performance of CT coronary angiography (CTCA) in detecting and excluding left main (LM) and/or three-vessel CAD ("high-risk" CAD) in symptomatic patients and to compare its discriminatory value with the Duke risk score and calcium score.......To determine the diagnostic performance of CT coronary angiography (CTCA) in detecting and excluding left main (LM) and/or three-vessel CAD ("high-risk" CAD) in symptomatic patients and to compare its discriminatory value with the Duke risk score and calcium score....

  3. Leak detection system with distributed microprocessor in the primary containment vessel

    International Nuclear Information System (INIS)

    Inahara, K.; Yoshioka, K.; Tomizawa, T.

    1980-01-01

    Responding to the demand for greater improvements of the safety monitoring system, less public radiation exposure, and increase of plant availability, measuring and control systems in nuclear power plants have undergone many improvements. Leak detection systems are also required to give earlier warning, additional accuracy, and continuous monitoring function. This paper describes the drywell sump leakage detection system utilizing a distributed microprocessor, which is a successful application owing to its versatile function and ease of installation. The microprocessor performs various functions such as a rate of level change computation, conversion to leakage flow rate, initiation of alarm, and sump pump control. This system has already been applied to three operating BWR plants that demonstrate its efficiency. (auth)

  4. Increase in cell adhesiveness on a poly(ethylene terephthalate) fabric by sintered hydroxyapatite nanocrystal coating in the development of an artificial blood vessel.

    Science.gov (United States)

    Furuzono, Tsutomu; Masuda, Miwa; Okada, Masahiro; Yasuda, Shoji; Kadono, Hiroyuki; Tanaka, Ryoichi; Miyatake, Kunio

    2006-01-01

    Nano-scaled sintered hydroxyapatite (HAp) crystals were covalently linked onto a poly(ethylene terephthalate) (PET) fabric substrate chemically modified by graft polymerization with gamma-methacryloxypropyl triethoxysilane (MPTS) for development of an artificial blood vessel. The weight gain of graft polymerization with poly(MPTS) on PET in benzyl alcohol containing H2O2 as an initiator increased as increasing the reaction time and finally reached a plateau value of about 3.5 wt%. The surface characterization of surface modification with poly(MPTS)-grafting was conducted by x-ray photoelectron spectroscopy. HAp nanocrystals of approximately 50 nm in diameter, monodispersed in pure ethanol, were coupled with alkoxysilyl groups of the poly(MPTS)-grafted PET substrate. The HAp nanocrystals were uniformly and strongly coated on the surface of the PET fabrics, although HAp particles adsorbed physically on the original PET without poly(MPTS) grafting were almost removed by ultrasonic wave treatment. More human umbilical vein endothelial cells adhered to the HAp/PET composite fabric compared with original PET after only 4 hours of initial incubation, and the same was observed on the collagen-coated PET. The coating of sintered HAp nanocrystals imparted bioactivity to the polyester substrate, which is a widely used biomedical polymer, without a coating of adhesion proteins derived from animals, such as collagen or gelatin. A prototype of an artificial blood vessel was finally fabricated by use of HAp/PET composite.

  5. P/Q-type and T-type voltage-gated calcium channels are involved in the contraction of mammary and brain blood vessels from hypertensive patients

    DEFF Research Database (Denmark)

    Thuesen, A D; Lyngsø, K S; Rasmussen, L

    2017-01-01

    : The P/Q-type antagonist ω-agatoxin IVA (10(-8) mol L(-1) ) and the T-type calcium blocker mibefradil (10(-7) mol L(-1) ) inhibited KCl depolarization-induced contraction in mammary arteries from hypertensive patients with no effect on blood vessels from normotensive patients. ω-Agatoxin IVA decreased......AIM: Calcium channel blockers are widely used in cardiovascular diseases. Besides L-type channels, T- and P/Q-type calcium channels are involved in the contraction of human renal blood vessels. It was hypothesized that T- and P/Q-type channels are involved in the contraction of human brain...... contraction in cerebral arterioles from hypertensive patients. L-type blocker nifedipine abolished the contraction in mammary arteries. PCR analysis showed expression of P/Q-type (Cav 2.1), T-type (Cav 3.1 and Cav 3.2) and L-type (Cav 1.2) calcium channels in mammary and cerebral arteries. Immunohistochemical...

  6. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    Science.gov (United States)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  7. Dynamic optical breast imaging: A novel technique to detect and characterize tumor vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, Laure S. [Universite Paris Descartes, Hopital Europeen Georges Pompidou, Radiology Department, 20 rue Leblanc, 75015 Paris (France); University Paris Descartes, Faculte de Medecine, EA4062, Laboratoire de Recherche en Imagerie, site Necker, 156 rue de Vaugirard, 75015 Paris (France)], E-mail: laure.fournier@gmail.com; Vanel, Daniel; Athanasiou, Alexandra [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France); Gatzemeier, Wolfgang [Division of Breast Surgery, Fondazione Salvatore Maugeri, Pavia (Italy); Masuykov, I.V. [DOBI Medical International Inc, Mahwah, NJ (United States); Padhani, Anwar R. [Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Dromain, Clarisse [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France); Galetti, Ken [Division of Breast Surgery, Fondazione Salvatore Maugeri, Pavia (Italy); Sigal, Robert [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France); Costa, Alberto [Paul Strickland Scanner Centre, Mount Vernon Hospital, Northwood (United Kingdom); Balleyguier, Corinne [Institut Gustave-Roussy, Radiology Department, 39 rue Camille Desmoulins, 94805 Villejuif (France)

    2009-01-15

    Purpose: To prospectively determine the diagnostic accuracy of optical absorption imaging in patients with Breast Imaging Reporting and Data System (BI-RADS) 3-5 breast lesions. Materials and methods: Forty-six patients with BI-RADS classification 3 (11%), 4 (44%) or 5 (44%) lesions, underwent a novel optical imaging examination using red light to illuminate the breast. Pressure was applied on the breast, and time-dependent curves of light absorption were recorded. Curves that consistently increased or decreased over time were classified as suspicious for malignancy. All patients underwent a core or surgical biopsy. Results: Optical mammography showed a statistical difference in numbers of suspect pixels between benign (N = 12) and malignant (N = 35) lesions (respectively 1325 vs. 3170, P = 0.002). In this population, optical imaging had a sensitivity of 74%, specificity of 92%, and diagnostic accuracy of 79%. The optical signal did not vary according to any other parameter including breast size or density, age, hormonal status or histological type of lesions. Conclusion: Optical imaging is a low-cost, non-invasive technique, yielding physiological information dependent on breast blood volume and oxygenation. It appears to have a good potential for discriminating benign from malignant lesions. Further studies are warranted to define its potential role in breast cancer imaging.

  8. Detection of melanoma cells suspended in mononuclear cells and blood plasma using photoacoustic generation

    Science.gov (United States)

    Spradling, Emily M.; Viator, John A.

    2009-02-01

    Melanoma is the deadliest form of skin cancer. Although the initial malignant cells are removed, it is impossible to determine whether or not the cancer has metastasized until a secondary tumor forms that is large enough to detect with conventional imaging. Photoacoustic detection of circulating melanoma cells in the bloodstream has shown promise for early detection of metastasis that may aid in treatment of this aggressive cancer. When blood is irradiated with energy from an Nd:YAG laser at 532 nm, photoacoustic signals are created and melanoma cells can be differentiated from the surrounding cells based on waveforms produced by an oscilloscope. Before this can be used as a diagnostic technique, however, we needed to investigate several parameters. Specifically, the current technique involves the in vitro separation of blood through centrifugation to isolate and test only the white blood cell layer. Using this method, we have detected a single cultured melanoma cell among a suspension of white blood cells. However, the process could be made simpler if the plasma layer were used for detection instead of the white blood cell layer. This layer is easier to obtain after blood separation, the optical difference between plasma and melanoma cells is more pronounced in this layer than in the white blood cell layer, and the possibility that any stray red blood cells could distort the results is eliminated. Using the photoacoustic apparatus, we detected no melanoma cells within the plasma of whole blood samples spiked with cultured melanoma cells.

  9. Lower Detection Probability of Avian Plasmodium in Blood Compared to Other Tissues.

    Science.gov (United States)

    Svensson-Coelho, M; Silva, G T; Santos, S S; Miranda, L S; Araújo-Silva, L E; Ricklefs, R E; Miyaki, C Y; Maldonado-Coelho, M

    2016-10-01

    We tested whether the probability of detecting avian haemosporidia (Plasmodium and Haemoproteus) using molecular techniques differs among blood, liver, heart, and pectoral muscle tissues. We used a paired design, sampling the 4 tissue types in 55 individuals of a wild South American suboscine antbird, the white-shouldered fire-eye (Pyriglena leucoptera). We also identified parasites to cytochrome b lineage. Detection probability was significantly lower in blood compared to the other 3 tissue types combined. Eight of 22 infections were not detected in blood samples; 4-7 infections were not detected in the other individual tissues. The same parasite lineage was recovered from different tissues.

  10. A Novel Thermal-Mechanical Detection System for Reactor Pressure Vessel Bottom Failure Monitoring in Severe Accidents

    International Nuclear Information System (INIS)

    Bi, Daowei; Bu, Jiangtao; Xu, Dongling

    2013-06-01

    Following the Fukushima Daiichi nuclear accident in Japan, there is an increased need of enhanced capabilities for severe accident management (SAM) program. Among others, a reliable method for detecting reactor pressure vessel (RPV) bottom failure has been evaluated as imperative by many utility owners. Though radiation and/or temperature measurement are potential solutions by tradition, there are some limitations for them to function desirably in such severe accident as that in Japan. To provide reliable information for assessment of accident progress in SAM program, in this paper we propose a novel thermal-mechanical detection system (TMDS) for RPV bottom failure monitoring in severe accidents. The main components of TMDS include thermally sensitive element, metallic cables, tension controlled switch and main control room annunciation device. With TMDS installed, there shall be a reliable means of keeping SAM decision-makers informed whether the RPV bottom has indeed failed. Such assurance definitely guarantees enhancement of severe accident management performance and significantly improve nuclear safety and thus protect the society and people. (authors)

  11. Compliant model of a coupled sequential coronary arterial bypass graft: effects of vessel wall elasticity and non-Newtonian rheology on blood flow regime and hemodynamic parameters distribution.

    Science.gov (United States)

    Kabinejadian, Foad; Ghista, Dhanjoo N

    2012-09-01

    We have recently developed a novel design for coronary arterial bypass surgical grafting, consisting of coupled sequential side-to-side and end-to-side anastomoses. This design has been shown to have beneficial blood flow patterns and wall shear stress distributions which may improve the patency of the CABG, as compared to the conventional end-to-side anastomosis. In our preliminary computational simulation of blood flow of this coupled sequential anastomoses design, the graft and the artery were adopted to be rigid vessels and the blood was assumed to be a Newtonian fluid. Therefore, the present study has been carried out in order to (i) investigate the effects of wall compliance and non-Newtonian rheology on the local flow field and hemodynamic parameters distribution, and (ii) verify the advantages of the CABG coupled sequential anastomoses design over the conventional end-to-side configuration in a more realistic bio-mechanical condition. For this purpose, a two-way fluid-structure interaction analysis has been carried out. A finite volume method is applied to solve the three-dimensional, time-dependent, laminar flow of the incompressible, non-Newtonian fluid; the vessel wall is modeled as a linearly elastic, geometrically non-linear shell structure. In an iteratively coupled approach the transient shell equations and the governing fluid equations are solved numerically. The simulation results indicate a diameter variation ratio of up to 4% and 5% in the graft and the coronary artery, respectively. The velocity patterns and qualitative distribution of wall shear stress parameters in the distensible model do not change significantly compared to the rigid-wall model, despite quite large side-wall deformations in the anastomotic regions. However, less flow separation and reversed flow is observed in the distensible models. The wall compliance reduces the time-averaged wall shear stress up to 32% (on the heel of the conventional end-to-side model) and somewhat

  12. Statistical Change Detection for Diagnosis of Buoyancy Element Defects on Moored Floating Vessels

    DEFF Research Database (Denmark)

    Blanke, Mogens; Fang, Shaoji; Galeazzi, Roberto

    2012-01-01

    Floating platforms with mooring systems are used extensively in off-shore operations. Part of the mooring systems are underwater buoyancy elements that are attached to the mooring lines. Loss or damage of a buoyancy element is invisible but changes the characteristics of the mooring system...... and alters its ability to provide the necessary responses to withstand loads from weather. Damage of a buoyancy element increases the operation risk and could even cause abortion during an oil-offloading. The objective of this paper is to diagnose the loss of a buoyancy element using diagnostic methods....... After residual generation, statistical change detection scheme is derived from mathematical models supported by experimental data. To experimentally verify loss of an underwater buoyancy element, an underwater line breaker is designed to create realistic replication of abrupt faults. The paper analyses...

  13. Training on insertion and retrieval of optional inferior vena cava filters for interventional radiologists with little or just some experience with the combined use of blood vessel and animal models.

    Science.gov (United States)

    Yamagami, Takuji; Hasebe, Terumitsu; Yoshimatsu, Rika; Matsumoto, Tomohiro; Hashimoto, Takeshi; Komemushi, Atsushi; Kamei, Seiji; Hagihara, Makiyo; Sato, Yozo; Kondo, Hiroshi; Inoue, Masanori; Nakatsuka, Atsuhiro; Takahashi, Makoto; Koizumi, Jun; Saito, Hiroya

    2013-01-01

    To evaluate the usefulness of a tool that we developed to simulate performance of insertion and retrieval of optional inferior vena cava filters to be additionally used in training of beginners with an animal model. Thirty young doctors who had little or no experience in insertion and/or retrieval of filters were subjects of this study to evaluate the training tool. Eleven trainees practiced both insertion and retrieval of filters first with the animal model then with the blood vessel model while 19 trainees first practiced with the blood vessel model then with the animal model. All trainees successfully inserted the filter. Two of the 11 trainees who used the animal model before the blood vessel model failed in retrieval, and 2 of the 19 trainees who used the blood vessel model before the animal model failed. In the former group, mean time for filter implantation and withdrawal in the animal model was 75 ± 62 s and 341 ± 238 s, respectively, and in the latter group were 54 ± 16 s and 311 ± 236 s, respectively. Training with the combination of a blood vessel model and animal model is helpful for beginners to learn to insert and withdraw optional filters.

  14. White blood cell-based detection of asymptomatic scrapie infection by ex vivo assays.

    Directory of Open Access Journals (Sweden)

    Sophie Halliez

    Full Text Available Prion transmission can occur by blood transfusion in human variant Creutzfeldt-Jakob disease and in experimental animal models, including sheep. Screening of blood and its derivatives for the presence of prions became therefore a major public health issue. As infectious titer in blood is reportedly low, highly sensitive and robust methods are required to detect prions in blood and blood derived products. The objectives of this study were to compare different methods--in vitro, ex vivo and in vivo assays--to detect prion infectivity in cells prepared from blood samples obtained from scrapie infected sheep at different time points of the disease. Protein misfolding cyclic amplification (PMCA and bioassays in transgenic mice expressing the ovine prion protein were the most efficient methods to identify infected animals at any time of the disease (asymptomatic to terminally-ill stages. However scrapie cell and cerebellar organotypic slice culture assays designed to replicate ovine prions in culture also allowed detection of prion infectivity in blood cells from asymptomatic sheep. These findings confirm that white blood cells are appropriate targets for preclinical detection and introduce ex vivo tools to detect blood infectivity during the asymptomatic stage of the disease.

  15. Hyperspectral imaging of the crime scene for detection and identification of blood stains

    Science.gov (United States)

    Edelman, G. J.; van Leeuwen, T. G.; Aalders, M. C. G.

    2013-05-01

    Blood stains are an important source of information in forensic investigations. Extraction of DNA may lead to the identification of victims or suspects, while the blood stain pattern may reveal useful information for the reconstruction of a crime. Consequently, techniques for the detection and identification of blood stains are ideally non-destructive in order not to hamper both DNA and the blood stain pattern analysis. Currently, forensic investigators mainly detect and identify blood stains using chemical or optical methods, which are often either destructive or subject to human interpretation. We demonstrated the feasibility of hyperspectral imaging of the crime scene to detect and identify blood stains remotely. Blood stains outside the human body comprise the main chromophores oxy-hemoglobin, methemoglobin and hemichrome. Consequently, the reflectance spectra of blood stains are influenced by the composite of the optical properties of the individual chromophores and the substrate. Using the coefficient of determination between a non-linear least squares multi-component fit and the measured spectra blood stains were successfully distinguished from other substances visually resembling blood (e.g. ketchup, red wine and lip stick) with a sensitivity of 100 % and a specificity of 85 %. The practical applicability of this technique was demonstrated at a mock crime scene, where blood stains were successfully identified automatically.

  16. Rapid white blood cell detection for peritonitis diagnosis

    Science.gov (United States)

    Wu, Tsung-Feng; Mei, Zhe; Chiu, Yu-Jui; Cho, Sung Hwan; Lo, Yu-Hwa

    2013-03-01

    A point-of-care and home-care lab-on-a-chip (LoC) system that integrates a microfluidic spiral device as a concentrator with an optical-coding device as a cell enumerator is demonstrated. The LoC system enumerates white blood cells from dialysis effluent of patients receiving peritoneal dialysis. The preliminary results show that the white blood cell counts from our system agree well with the results from commercial flow cytometers. The LoC system can potentially bring significant benefits to end stage renal disease (ESRD) patients that are on peritoneal dialysis (PD).

  17. Effect of volume of blood cultured on detection of Streptococcus viridans bacteraemia.

    Science.gov (United States)

    Shanson, D C; Thomas, F; Wilson, D

    1984-01-01

    Fifty eight patients undergoing dental extraction each had 45 ml blood collected. This was divided into 30 ml and 15 ml blood samples for culture. The 30 ml sample was inoculated into 120 ml nutrient broth with 0.05% liquoid and the 15 ml sample into 60 ml of identical broth so that the final dilution of blood in broth was always 1/5. Bacteraemia due to viridans streptococci was found in 27 and 15 patients by culturing the 30 ml and 15 ml blood samples respectively. Only one further case of streptococcal bacteraemia was detected by culture of the total volume of blood collected (45 ml) rather than culture of the 30 ml blood sample alone. These findings suggest that the culture of 30 ml blood results in the detection of up to 80% more blood cultures yielding Streptococcus viridans than the culture of only 15 ml blood. The collection of more than 30 ml blood for each culture is unlikely to prove worthwhile. It is suggested that 30 ml rather than 15 ml blood is probably the optimal volume of blood for each culture of S viridans when patients with suspected infective endocarditis are investigated. PMID:6373833

  18. Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography-a phantom study

    International Nuclear Information System (INIS)

    Yamada, Minoru; Jinzaki, Masahiro; Tanami, Yutaka; Matsumoto, Kazuhiro; Ueno, Akihisa; Kuribayashi, Sachio; Nukui, Masatake; Imai, Yasuhiro; Ishihara, Yotaro; Nishide, Akihiko; Sasaki, Kosuke

    2011-01-01

    The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

  19. Detecting Methemoglobinemia in Animals with a Drop of Blood.

    Directory of Open Access Journals (Sweden)

    Toni G Patton

    Full Text Available A major concern during pesticide development and use is the impact on non-target species, such as raptors or domestic cats and dogs. Sodium nitrite and para-aminopropiophenone (PAPP are two toxicants currently being studied for the control of invasive species, such as starlings and feral swine. When given to an animal these compounds oxidize hemoglobin, which renders it unable to carry oxygen resulting in methemoglobinemia. This study developed a method to estimate methemoglobin levels in mammals and birds by examining the efficacy of sodium nitrite to induce the conversion of hemoglobin to methemoglobin. Varying concentrations of sodium nitrite were added to aliquots of coyote, vole, feral swine, starling, and duck blood, collected from captive animals. The blood samples were analyzed spectrophotometrically to determine percent methemoglobin and digitally to determine red color values (RCV associated with different methemoglobin levels. The avian and mammalian blood reached 100% methemoglobin levels at 200 mM and 15 mM sodium nitrite, respectively. All animals had similar RCV for a given percent methemoglobin. In conclusion, this study developed a procedure to quickly determine methemoglobin levels in mammals and birds. Furthermore, percent methemoglobin can be estimated with one standard curve from any animal species and an image of a blood spot. The technique will be useful during field studies, in agricultural areas, or in a veterinarian's office for the rapid diagnosis of methemoglobinemia in non-target animals that have eaten toxicants/baits or baited animals.

  20. A New Technology for Detecting Cerebral Blood Flow

    DEFF Research Database (Denmark)

    Schytz, Henrik W; Guo, Song; Jensen, Lars T

    2012-01-01

    There is a need for real-time non-invasive, continuous monitoring of cerebral blood flow (CBF) during surgery, in intensive care units and clinical research. We investigated a new non-invasive hybrid technology employing ultrasound tagged near infrared spectroscopy (UT-NIRS) that may estimate...

  1. Reliability of bedside blood glucose estimating methods in detecting ...

    African Journals Online (AJOL)

    Background: Hypoglycaemia occurs in many disease states common in the tropics. Facilities and skilled manpower required for laboratory blood glucose measurement are not always available in health facilities in developing countries. Objective: The study was carried out to determine the validity of bedside methods of ...

  2. Identification of pro-angiogenic markers in blood vessels from stroked-affected brain tissue using laser-capture microdissection

    Directory of Open Access Journals (Sweden)

    Baldellou Maribel

    2009-03-01

    Full Text Available Abstract Background Angiogenesis correlates with patient survival following acute ischaemic stroke, and survival of neurons is greatest in tissue undergoing angiogenesis. Angiogenesis is critical for the development of new microvessels and leads to re-formation of collateral circulation, reperfusion, enhanced neuronal survival and improved recovery. Results Here, we have isolated active (CD105/Flt-1 positive and inactive (CD105/Flt-1 minus (n=5 micro-vessel rich-regions from stroke-affected and contralateral tissue of patients using laser-capture micro-dissection. Areas were compared for pro- and anti-angiogenic gene expression using targeted TaqMan microfluidity cards containing 46 genes and real-time PCR. Further analysis of key gene de-regulation was performed by immunohistochemistry to define localization and expression patterns of identified markers and de novo synthesis by human brain microvessel endothelial cells (HBMEC was examined following oxygen-glucose deprivation (OGD. Our data revealed that seven pro-angiogenic genes were notably up-regulated in CD105 positive microvessel rich regions. These were, beta-catenin, neural cell adhesion molecule (NRCAM, matrix metalloproteinase-2 (MMP-2, tissue inhibitor of matrix metalloproteinase-1 (TIMP-1, hepatocyte growth factor-alpha (HGF-alpha, monocyte chemottractant protein-1 (MCP-1 and and Tie-2 as well as c-kit. Immunohistochemistry demonstrated strong staining of MMP-2, HGF-alpha, MCP-1 and Tie-2 in stroke-associated regions of active remodeling in association with CD105 positive staining. In vitro, OGD stimulated production of Tie-2, MCP-1 and MMP-2 in HBMEC, demonstrated a de novo response to hypoxia. Conclusion In this work we have identified concurrent activation of key angiogenic molecules associated with endothelial cell migration, differentiation and tube-formation, vessel stabilization and stem cell homing mechanisms in areas of revascularization. Therapeutic stimulation of these

  3. Pre-operative image-based segmentation of the cranial nerves and blood vessels in microvascular decompression: Can we prevent unnecessary explorations?

    Science.gov (United States)

    Dolati, Parviz; Golby, Alexandra; Eichberg, Daniel; Abolfotoh, Mohamad; Dunn, Ian F; Mukundan, Srinivasan; Hulou, Mohamed M; Al-Mefty, Ossama

    2015-12-01

    This study was conducted to validate the accuracy of image-based pre-operative segmentation using the gold standard endoscopic and microscopic findings for localization and pre-operative diagnosis of the offensive vessel. Fourteen TN and 6 HS cases were randomly selected. All patients had 3T MRI, which included thin-sectioned 3D space T2, 3D Time of Flight and MPRAGE Sequences. Imaging sequences were loaded in BrainLab iPlanNet and fused. Individual segmentation of the affected cranial nerves and the compressing vascular structure was performed by a neurosurgeon, and the results were compared with the microscopic and endoscopic findings by two blinded neurosurgeons. For each case, at least three neurovascular landmarks were targeted. Each segmented neurovascular element was validated by manual placement of the navigation probe over each target, and errors of localization were measured in mm. All patients underwent retro-sigmoid craniotomy and MVD using both microscope and endoscope. Based on image segmentation, the compressing vessel was identified in all cases except one, which was also negative intraoperatively. Perfect correspondence was found between image-based segmentation and endoscopic and microscopic images and videos (Dice coefficient of 1). Measurement accuracy was 0.45 ± 0.21 mm (mean ± SD). Image-based segmentation is a promising method for pre-operative identification and localization of offending blood vessels causing HFS and TN. Using this method may prevent some unnecessary explorations on especially atypical cases with no vascular contacts. However, negative pre-operative image segmentation may not preclude one from exploration in classic cases of TN or HFS. A multicenter study with larger number of cases is recommended. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Experimental investigations concerning the suitability of channel systems for liner leak detection and drainage of a prestressed concrete vessel

    International Nuclear Information System (INIS)

    Nickel, M.; Breitbach, G.; Altes, J.; Escherich, K.H.; Wolters, J.

    1985-02-01

    The iternal surfaces of prestressed concrete pressure vessels are fitted with a steel liner to preserve the gas tightness of the primary circuit. Because of the high quality manufacture and the loading conditions a linear failure can be practically excluded. However, if it is hypothetically assumed, that a leak develops during reactor operation, it may be difficult to determine the position of the leak, because the linear area is very large. For tightness surveillance and for venting channel systems installed in close proximity to the linear are suitable. The suitability of such channels for leak detection, localisation and venting was investigated experimentally. A concrete wall (length 2.5 m, height 2.0 m, thickness 0.5 m) was constructed, covered on one side with a steel liner. Behind the liner two different channel systems have been installed. For the simulation of leaks holes were drilled into the liner. The experimental programm contained the following measurements: determination of gas flow rates into the different leaks, distribution of leakage gas over the array of channels and determination of pressures into the concrete and immediately behind the liner. The experiments have shown, that channel arrays immediately adjacent to the liner are the most suitable systems for localisation and controlled exhaust of leakage gas. The suitability decreases, if the channels are set into the concrete somewhat distant from the liner. (orig.) [de

  5. [Detection and analysis of anti-Rh blood group antibodies].

    Science.gov (United States)

    Wu, Yuan-jun; Wu, Yong; Chen, Bao-chan; Liu, Yan

    2008-06-01

    To study the prevalence and distribution of anti-Rh blood group antibodies in Chinese population and its clinical significance. Irregular antibodies were screened and identified by Microcolum Gel Coomb's test. For those identified as positive anti-Rh samples, monoclonal antibodies (anti-D, -C, -c, -E and -e) were used to identify the specific antigen and confirm the accuracy of the irregular antibody tests. The titers, Ig-types and 37 Degrees Celsius-reactivity were tested to confirm its clinical significance. For evaluation of the origin of irregular antibodies, histories of pregnancy and transfusion were reviewed. For the newborns who had positive antibodies, their mothers were tested simultaneously to confirm the origin of the antibodies. 47 out of 54 000 (0.087%) patients were identified as positive with Rh blood group antibodies.Of them, 27 cases had history of pregnancy, 13 had transfusion and 1 had the histories of both. 6 newborns had antibodies derived form their mothers. The specificity of the antibody was as follows: 29 with anti-E (61.70%), 8 with anti-D (17.02%), anti-cE 5(10.64%), 4 with anti-c (8.51%) and 1 with anti-C (2.13%). All the 47 Rh blood group antibodies were IgG or IgG+IgM, and were reactive to red blood cells with corresponding antigens at 37 Degrees Celsius, with a highest titer of 1:4 096. The prevalence of Rh antibodies is lower in Chinese population as compared with that in White population.Of all the antibodies, anti-E is most frequently identified and anti-D was declining. Alloimmunization by pregnancy and transfusion is the major cause of Rh antibody production. Rh blood group antibodies derived from mothers are the major cause of Non-ABO-HDN.

  6. In-vessel co-composting of horse stable bedding waste and blood meal at different C/N ratios: process evaluation.

    Science.gov (United States)

    Wong, Jonathan W C; Selvam, Ammaiyappan; Zhao, Zhenyong; Karthikeyana, Obuli P; Yu, Shuk Man; Law, Alex C W; Chung, Patricia C P

    2012-12-01

    Abattoir blood meal is rich in nitrogen and its potential as a co-composting material for horse stable bedding waste was evaluated at two C/N ratios -32 (LBM, low blood meal) and 16 (HBM, high blood meal) - to improve the nutrient contents of the final compost. The mix was composted for 7 days in a 10 tonne/day in-vessel composter and cured aerobically. After 56 days ofcomposting, the ammoniacal-N, CO2 evolution rate and C/N ratio of both LBM and HBM were within the guideline values; however, delayed decomposition and lower seed germination index were observed with HBM. In addition, HBM resulted in 84% loss of the initial ammoniacal-N. Almost similar organic decompositions, 62.4% and 59.6% with LBM and HBM, respectively, were achieved. However, a stable compost product can be obtained within 6-7 weeks with LBM, whereas >8 weeks were required for HBM composting. Therefore, co-composting at the C/N ratio of 32 is recommended to achieve odour-free and faster composting.

  7. Transient electro-magneto-hydrodynamic two-phase blood flow and thermal transport through a capillary vessel.

    Science.gov (United States)

    Mirza, I A; Abdulhameed, M; Vieru, D; Shafie, S

    2016-12-01

    Therapies with magnetic/electromagnetic field are employed to relieve pains or, to accelerate flow of blood-particles, particularly during the surgery. In this paper, a theoretical study of the blood flow along with particles suspension through capillary was made by the electro-magneto-hydrodynamic approach. Analytical solutions to the non-dimensional blood velocity and non-dimensional particles velocity are obtained by means of the Laplace transform with respect to the time variable and the finite Hankel transform with respect to the radial coordinate. The study of thermally transfer characteristics is based on the energy equation for two-phase thermal transport of blood and particles suspension with viscous dissipation, the volumetric heat generation due to Joule heating effect and electromagnetic couple effect. The solution of the nonlinear heat transfer problem is derived by using the velocity field and the integral transform method. The influence of dimensionless system parameters like the electrokinetic width, the Hartman number, Prandtl number, the coefficient of heat generation due to Joule heating and Eckert number on the velocity and temperature fields was studied using the Mathcad software. Results are presented by graphical illustrations. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. On the bifurcation of blood vessels--Wilhelm Roux's doctoral thesis (Jena 1878)--a seminal work for biophysical modelling in developmental biology.

    Science.gov (United States)

    Kurz, H; Sandau, K; Christ, B

    1997-02-01

    Wilhelm Roux's doctoral thesis described the relationship between the angle and diameter of bifurcating blood vessels. We have re-read this work in the light of biophysics and developmental biology and found two remarkable aspects hidden among a multitude of observations, rules and exceptions to these rules. First, the author identified the major determinants involved in vascular development; genetics, cybernetics, and mechanics; moreover, he knew that he could not deal with the genetic and regulatory aspects, and could hardly treat the mechanical part adequately. Second, he was deeply convinced that the laws of physics determine the design of organisms, and that a necessity for optimality was inherent in development. We combined the analysis of diameter relationships with the requirement for optimality in a stochastic biophysical model, and concluded that a constant wall-stress condition could define a minimum wall-tissue optimum during arterial development. Hence, almost 120 years after Wilhelm Roux's pioneering work, our model indicates one possible way in which physical laws have determined the evolution of regulatory and structural properties in vessel wall development.

  9. The use of cluster analysis method for the localization of acoustic emission sources detected during the hydrotest of PWR pressure vessels

    International Nuclear Information System (INIS)

    Liska, J.; Svetlik, M.; Slama, K.

    1982-01-01

    The acoustic emission method is a promising tool for checking reactor pressure vessel integrity. Localization of emission sources is the first and the most important step in processing emission signals. The paper describes the emission sources localization method which is based on cluster analysis of a set of points depicting the emission events in the plane of coordinates of their occurrence. The method is based on using this set of points for constructing the minimum spanning tree and its partition into fragments corresponding to point clusters. Furthermore, the laws are considered of probability distribution of the minimum spanning tree edge length for one and several clusters with the aim of finding the optimum length of the critical edge for the partition of the tree. Practical application of the method is demonstrated on localizing the emission sources detected during a hydrotest of a pressure vessel used for testing the reactor pressure vessel covers. (author)

  10. Fluorescence spectra of blood and urine for cervical cancer detection

    Science.gov (United States)

    Masilamani, Vadivel; AlSalhi, Mohamad Saleh; Vijmasi, Trinka; Govindarajan, Kanaganaj; Rathan Rai, Ram; Atif, Muhammad; Prasad, Saradh; Aldwayyan, Abdullah S.

    2012-09-01

    In the current study, the fluorescence emission spectra (FES) and Stokes shift spectra (SSS) of blood and urine samples of cervical cancer patients were obtained and compared to those of normal controls. Both spectra showed that the relative intensity of biomolecules such as porphyrin, collagen, Nicotinamide adenine dinucleotide, and flavin were quite out of proportion in cervical cancer patients. The biochemical mechanism for the elevation of these fluorophores is not yet definitive; nevertheless, these biomolecules could serve as tumor markers for diagnosis, screening, and follow-up of cervical cancers. To the best of our knowledge, this is the first report on FES and SSS of blood and urine of cervical cancer patients to give a sensitivity of 80% and specificity of 78%.

  11. Application of Dried Blood Spots on Filter Paper for Detection of HIV ...

    African Journals Online (AJOL)

    Moreover the present technique of collecting blood for diagnosis is associated with increased risk of infection, loss and contamination of specimen. This study aimed at evaluating the use of blood spot dried on filter paper (under different storage conditions) for detection of HIV antibodies in patient\\'s serum as an alternative ...

  12. Detection of bacterial DNA in blood samples from febrile patients: underestimated infection or emerging contamination?

    NARCIS (Netherlands)

    Peters, Remco P. H.; Mohammadi, Tamimount; Vandenbroucke-Grauls, Christina M. J. E.; Danner, Sven A.; van Agtmael, Michiel A.; Savelkoul, Paul H. M.

    2004-01-01

    We applied real-time broad-range polymerase chain reaction (PCR) to detect bacteraemia in blood from febrile patients. Interpretation of amplification results in relation to clinical data and blood culture outcome was complex, although the reproducibility of the PCR results was good. Sequencing

  13. Flow measurements in a blood-perfused collagen vessel using x-ray micro-particle image velocimetry.

    Directory of Open Access Journals (Sweden)

    Elizabeth Antoine

    Full Text Available Blood-perfused tissue models are joining the emerging field of tumor engineering because they provide new avenues for modulation of the tumor microenvironment and preclinical evaluation of the therapeutic potential of new treatments. The characterization of fluid flow parameters in such in-vitro perfused tissue models is a critical step towards better understanding and manipulating the tumor microenvironment. However, traditional optical flow measurement methods are inapplicable because of the opacity of blood and the thickness of the tissue sample. In order to overcome the limitations of optical method we demonstrate the feasibility of using phase-contrast x-ray imaging to perform microscale particle image velocimetry (PIV measurements of flow in blood perfused hydrated tissue-representative microvessels. However, phase contrast x-ray images significantly depart from the traditional PIV image paradigm, as they have high intensity background, very low signal-to-noise ratio, and volume integration effects. Hence, in order to achieve accurate measurements special attention must be paid to the image processing and PIV cross-correlation methodologies. Therefore we develop and demonstrate a methodology that incorporates image preprocessing as well as advanced PIV cross-correlation methods to result in measured velocities within experimental uncertainty.

  14. A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment.

    Science.gov (United States)

    Vutukuru, Manjula Ramya; Sharma, Divya Khandige; Ragavendar, M S; Schmolke, Susanne; Huang, Yiwei; Gumbrecht, Walter; Mitra, Nivedita

    2016-12-01

    Molecular diagnostics is a promising alternative to culture based methods for the detection of bloodstream infections, notably due to its overall lower turnaround time when starting directly from patient samples. Whole blood is usually the starting diagnostic sample in suspected bloodstream infections. The detection of low concentrations of pathogens in blood using a molecular assay necessitates a fairly high starting volume of blood sample in the range of 5-10mL. This large volume of blood sample has a substantial accompanying human genomic content that interferes with pathogen detection. In this study, we have established a workflow using magnetic beads coated with Apolipoprotein H that makes it possible to concentrate pathogens from a 5.0mL whole blood sample, thereby enriching pathogens from whole blood background and also reducing the sample volume to ~200μL or less. We have also demonstrated that this method of enrichment allows detection of 1CFU/mL of Escherichia coli, Enterococcus gallinarum and Candida tropicalis from 5mL blood using quantitative PCR; a detection limit that is not possible in unenriched samples. The enrichment method demonstrated here took 30min to complete and can be easily integrated with various downstream molecular and microbiological techniques. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Optimization of microCT imaging and blood vessel diameter quantitation of preclinical specimen vasculature with radiopaque polymer injection medium.

    Directory of Open Access Journals (Sweden)

    Sergio X Vasquez

    2011-04-01

    Full Text Available Vascular networks within a living organism are complex, multi-dimensional, and challenging to image capture. Radio-angiographic studies in live animals require a high level of infrastructure and technical investment in order to administer costly perfusion mediums whose signals metabolize and degrade relatively rapidly, diminishing within a few hours or days. Additionally, live animal specimens must not be subject to long duration scans, which can cause high levels of radiation exposure to the specimen, limiting the quality of images that can be captured. Lastly, despite technological advances in live-animal specimen imaging, it is quite difficult to minimize or prevent movement of a live animal, which can cause motion artifacts in the final data output. It is demonstrated here that through the use of postmortem perfusion protocols of radiopaque silicone polymer mediums and ex-vivo organ harvest, it is possible to acquire a high level of vascular signal in preclinical specimens through the use of micro-computed tomographic (microCT imaging. Additionally, utilizing high-order rendering algorithms, it is possible to further derive vessel morphometrics for qualitative and quantitative analysis.

  16. Validation of an open source framework for the simulation of blood flow in rigid and deformable vessels.

    Science.gov (United States)

    Passerini, T; Quaini, A; Villa, U; Veneziani, A; Canic, S

    2013-11-01

    We discuss in this paper the validation of an open source framework for the solution of problems arising in hemodynamics. The proposed framework is assessed through experimental data for fluid flow in an idealized medical device with rigid boundaries and a numerical benchmark for flow in compliant vessels. The core of the framework is an open source parallel finite element library that features several algorithms to solve both fluid and fluid-structure interaction problems. The numerical results for the flow in the idealized medical device (consisting of a conical convergent, a narrow throat, and a sudden expansion) are in good quantitative agreement with the measured axial components of the velocity and pressures for three different flow rates corresponding to laminar, transitional, and turbulent regimes. We emphasize the crucial role played by the accuracy in performing numerical integration, mesh, and time step to match the measurements. The numerical fluid-structure interaction benchmark deals with the propagation of a pressure wave in a fluid-filled elastic tube. The computed pressure wave speed and frequency of oscillations, and the axial velocity of the fluid on the tube axis are close to the values predicted by the analytical solution associated with the benchmark. A detailed account of the methods used for both benchmarks is provided. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Picomolar detection of carcinoembryonic antigen in whole blood using microfluidics and surface-enhanced Raman spectroscopy.

    Science.gov (United States)

    Zou, Kun; Gao, Zhigang; Deng, Quanfeng; Luo, Yong; Zou, Lijuan; Lu, Yao; Zhao, Weijie; Lin, Bingcheng

    2016-03-01

    Carcinoembryonic antigen (CEA) is a wide-spectrum biomarker. Clinically, we generally use serum sample to detect CEA, which needs to be centrifuged to pretreat the raw blood sample. In this study, we realized direct CEA detection in raw blood samples exploiting microfluidics. The LOD was as low as 10(-12) M. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Research vessels

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, P.S.

    The role of the research vessels as a tool for marine research and exploration is very important. Technical requirements of a suitable vessel and the laboratories needed on board are discussed. The history and the research work carried out...

  19. Functional and pharmacological consequences of the distribution of voltage-gated calcium channels in the renal blood vessels

    DEFF Research Database (Denmark)

    Hansen, P B L

    2013-01-01

    -type is usually associated with vascular contractility. However, the L-, T- and P-/Q-types of calcium channels are present in the renal vasculature and are differentially involved in controlling vascular contractility, thereby contributing to regulation of kidney function and blood pressure. In the preglomerular....... Therefore, the distinct effect obtained by inhibiting a given subtype or set of channels under experimental settings should be considered when choosing a calcium blocker for treatment. T-type channels seem to be crucial for regulating the GFR and the filtration fraction. Use of blockers is expected to lead...

  20. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    Science.gov (United States)

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  1. (18)F-FDG PET/CT for the detection of large vessel vasculitis in patients with polymyalgia rheumatica.

    Science.gov (United States)

    Lavado-Pérez, C; Martínez-Rodríguez, I; Martínez-Amador, N; Banzo, I; Quirce, R; Jiménez-Bonilla, J; De Arcocha-Torres, M; Bravo-Ferrer, Z; Jiménez-Alonso, M; López-Defilló, J L; Blanco, R; González-Gay, M A; Carril, J M

    2015-01-01

    Polymyalgia rheumatica (PMR) may present together with large vessel vasculitis (LVV), and frequently requires a more intensive therapy. The aim of the study was to evaluate the impact of (18)F-FDG PET/CT in the diagnosis and management of LVV associated to PMR. This prospective study included 40 consecutive patients (27 women/13 men, 68.10±10.27 years) with PMR and suspicion of associated LVV submitted for (18)F-FDG PET/CT. A PET/CT scan was obtained 180 min after (18)F-FDG intravenous injection. A visual analysis was performed on the images. Five vascular regions were evaluated: supra-aortic trunks (SAT), thoracic aorta (TA), abdominal aorta (AA), iliac arteries (IA), and femoral/tibioperoneal arteries (FTA). The intensity of uptake was graded from 0 to 3. A final diagnosis of LVV was established in 26/40 patients (65%). In the 26 patients with a diagnosis of LVV, the highest intensity of (18)F-FDG uptake was observed in the TA, SAT, and FTA. All of these patients showed uptake at the TA, with grade 2 and 3 in most cases. In 4 of the 14 patients without LVV, no uptake was observed in any vascular region, and in the other 10 patients only a grade 1 uptake was observed in 1 or to 2 territories. Out of the 20 treated LVV patients, (18)F-FDG PET/CT led to a therapeutic change in 17 (85%). (18)F-FDG PET/CT was useful in identifying patients with LVV associated to PMR. The detection of vascular inflammation had an important impact, and led to a change of treatment in a high percentage of patients with LVV. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  2. Time course of radiometric detection of positive blood cultures in childhood

    International Nuclear Information System (INIS)

    Meadow, W.L.; Schwartz, I.K.

    1986-01-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children

  3. Time course of radiometric detection of positive blood cultures in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Meadow, W.L.; Schwartz, I.K.

    1986-05-01

    We have determined the time course of radiometric detection of microbial growth in 2348 positive blood culture specimens obtained at Wyler Children's Hospital during a 5-year interval. Overall 72 and 88% of isolates were detected within 48 and 72 hours after sampling, respectively. For pathogenic organisms aerobic detection was generally more rapid and more inclusive than anaerobic detection. At 48 hours of incubation the detection of six potential pathogens (Salmonella sp., Haemophilus influenzae, Group D streptococci, Neisseria meningitidis, coagulase-negative staphylococci, Candida sp.) was significantly delayed compared with detection of other pathogenic organisms recovered from blood. At 72 hours of incubation the detection rates remained less than 95% for H. influenzae, Staphylococcus aureus, Klebsiella sp., coagulase-negative staphylococci, Group D streptococci and Candida sp. These data should assist clinical decisions regarding duration of antibiotic therapy for the presumptive diagnosis of bacteremia in children.

  4. Comparison between Plasma and Whole Blood Specimens for Detection of Aspergillus DNA by PCR

    Science.gov (United States)

    Loeffler, Juergen; Hebart, Holger; Brauchle, Ulrike; Schumacher, Ulrike; Einsele, Hermann

    2000-01-01

    Ninety-six plasma and whole blood specimens from nine selected patients were analyzed for the presence of Aspergillus DNA. Nineteen specimens from three patients with proven aspergillosis were PCR positive in both materials, whereas an additional 22 were PCR positive in whole blood only. All 36 samples from six patients without signs of aspergillosis were negative in both assays. We conclude that although plasma and whole blood spiked with Aspergillus conidia showed an identical lower detection limit (10 CFU), the sensitivity of plasma PCR was lower than that of PCR performed on whole blood samples. PMID:11015412

  5. Risk of malaria transmission through blood transfusion and its detection by serological method

    International Nuclear Information System (INIS)

    Rahman, M.; Akhtar, G.N.; Rashid, S.; Lodhi, Y.

    2003-01-01

    Objective: To assess the risk of transmission of malaria through blood transfusion, and compare efficacy of testing by immuno chromatographic (ICT) devices vis a vis peripheral blood film (PBF). Results: Amongst healthy blood donors we did not find even a single case of malaria and there was no report of persistent post transfusion pyrexia. We are unable to comment on species frequency in blood donors. However, amongst known patients of malaria we found a higher frequency of Plasmodium viax(P.v) as compared to Plasmodium falciparum(P.f). Testing by serological method, helped us to diagnose 5% of our patients who were missed by peripheral blood films. Conclusion: Between properly selected voluntary non-remunerated blood donors the incidence of malaria transmission is zero and the blood is safe for transfusion. Serological testing shows good correlation with peripheral blood film detection. In fact, it can detect the disease even when film detection has been unsuccessful. If proper donor selection criteria are observed there is little risk of transmitting malaria through transfusion. However, as the donor pool in the Service is not necessarily totally the of voluntary non-remunerated donors and substantive numbers of replacement/first time, occasionally uneducated/unaware donors, are being bled, screening for malaria will not be totally unrewarding. (author)

  6. Detection of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa)

    Science.gov (United States)

    Ekawati, ER; Yusmiati, S. N. H.

    2018-01-01

    Blood cockle (Anadara granosa) has high level of zinc and protein, which is beneficial for therapeutic function for malnourished particularly stunting case in children. Zinc in animal foods is more absorbable than that from vegetable food. Blood cockle (Anadara granosa) is rich in nutrient and an excellent environment for the growth of microorganisms. This research aimed to identify the contamination of Salmonella sp., Vibrio sp. and total plate count bacteria on blood cockle (Anadara granosa). This was observation research with laboratory analysis. Salmonella sp. and Vibrio sp. were detected from blood cockle. Total plate count was determine of the total amount of the bacteria. Results detected from 20 samples of blood cockle showed that all samples were negative of Salmonella sp. and 1 sample positive Vibrio sp. The result of total plate count bacteria was sample.

  7. [Detection and documentation of masked blood stains with infrared technique].

    Science.gov (United States)

    Du Chesne, A; Bajanowski, T; Brinkmann, B

    1993-01-01

    On dark textiles the visualization of blood stains with the naked eye is either difficult or impossible. In experimental stains and in case work stains we have applied an infrared (IR) video camera in combination with a video printer. As an alternative, an IR goggle was used which could also be connected with a video printer. The results obtained on a variety of different stains and stain carriers are encouraging. Stains showing poor contrast usually become more contrasted. Stains which are partly masked can become complete. Masked stains can become visible. The system is not effective in all combinations of stains and carriers. But it solves a great proportion of formerly problematic cases. Documentation of results is quite easy if a videoprinter is used.

  8. Hemagglutination detection for blood typing based on waveguide-mode sensors

    Directory of Open Access Journals (Sweden)

    Hiroki Ashiba

    2015-03-01

    Full Text Available ABO and Rh(D blood typing is one of the most important tests performed prior to blood transfusion. Although on-site blood testing is desirable for expedient blood transfusion procedure, most conventional methods and instruments lack the required usability or portability. Here, we describe a novel method, based on the detection of hemagglutination using an optical waveguide-mode sensor, for on-site use. The reflectance spectrum of blood alone and that of blood mixed with antibody reagents was measured using the waveguide-mode sensor. Differences in reflectance by agglutinated and non-agglutinated blood samples were observed at the bottom of the spectral dips; due to differences in the manner in which red blood cells interacted with the surface of the sensor chip. Following the addition of the antibody, blood types A, B, O, and AB were clearly distinguishable and Rh(D typing was also possible using the waveguide-mode sensor. Furthermore, the waveguide-mode-based measurement exhibited the potential to detect weak agglutination, which is difficult for human eyes to distinguish. Thus, this method holds great promise for application in novel on-site test instruments.

  9. Detection of drugs in 275 alcohol-positive blood samples of Korean drivers.

    Science.gov (United States)

    Kim, Eunmi; Choe, Sanggil; Lee, Juseon; Jang, Moonhee; Choi, Hyeyoung; Chung, Heesun

    2016-08-01

    Since driving under the influence of drugs (DUID) is as dangerous as drink-driving, many countries regulate DUID by law. However, laws against the use of drugs while driving are not yet established in Korea. In order to investigate the type and frequency of drugs used by drivers in Korea, we analyzed controlled and non-controlled drugs in alcohol-positive blood samples. Total 275 blood samples were taken from Korean drivers, which were positive in roadside alcohol testing. The following analyses were performed: blood alcohol concentrations by GC; screening for controlled drugs by immunoassay and confirmation for positive samples by GC-MS. For the detection of DUID related drugs in blood samples, a total of 49 drugs were selected and were examined by GC-MS. For a rapid detection of these drugs, an automated identification software called "DrugMan" was used. Concentrations of alcohol in 275 blood samples ranged from 0.011 to 0.249% (average 0.119%). Six specimens showed positive results by immunoassay: one methamphetamine and five benzodiazepines I. By GC-MS confirmation, only benzodiazepines in four cases were identified, while methamphetamine and benzodiazepine in two cases were not detected from the presumptive positive blood samples. Using DrugMan, four drugs were detected; chlorpheniramine (5)*, diazepam (4), dextromethorphan (1) and doxylamine (1). In addition, ibuprofen (1), lidocaine (1) and topiramate (1) were also detected as general drugs in blood samples ('*' indicates frequency). The frequency of drug abuse by Korean drivers was relatively low and a total 14 cases were positive in 275 blood samples with a ratio of 5%. However it is necessary to analyze more samples including alcohol negative blood, and to expand the range of drug lists to get the detailed information. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Earlier stages of colorectal cancer detected with immunochemical faecal occult blood tests

    NARCIS (Netherlands)

    van Rossum, L. G. M.; van Rijn, A. F.; van Munster, I. P.; Jansen, J. B. M. J.; Fockens, P.; Laheij, R. J. F.; Dekker, E.

    2009-01-01

    Background: The aim of colorectal cancer screening is to improve prognosis by the detection of early cancer and precursor stages. We compared the stage distribution of asymptomatic colorectal cancer patients detected by a positive immunochemical or guaiac-based faecal occult blood test (FOBT) with

  11. In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice

    Energy Technology Data Exchange (ETDEWEB)

    Tung, Yao-Sheng; Vlachos, Fotios; Choi, James J; Deffieux, Thomas; Selert, Kirsten; Konofagou, Elisa E, E-mail: ek2191@columbia.ed [Department of Biomedical Engineering, Columbia University, New York, NY (United States)

    2010-10-21

    The in vivo cavitation response associated with blood-brain barrier (BBB) opening as induced by transcranial focused ultrasound (FUS) in conjunction with microbubbles was studied in order to better identify the underlying mechanism in its noninvasive application. A cylindrically focused hydrophone, confocal with the FUS transducer, was used as a passive cavitation detector (PCD) to identify the threshold of inertial cavitation (IC) in the presence of Definity (registered) microbubbles (mean diameter range: 1.1-3.3 {mu}m, Lantheus Medical Imaging, MA, USA). A vessel phantom was first used to determine the reliability of the PCD prior to in vivo use. A cerebral blood vessel was simulated by generating a cylindrical channel of 610 {mu}m in diameter inside a polyacrylamide gel and by saturating its volume with microbubbles. The microbubbles were sonicated through an excised mouse skull. Second, the same PCD setup was employed for in vivo noninvasive (i.e. transdermal and transcranial) cavitation detection during BBB opening. After the intravenous administration of Definity (registered) microbubbles, pulsed FUS was applied (frequency: 1.525 or 1.5 MHz, peak-rarefactional pressure: 0.15-0.60 MPa, duty cycle: 20%, PRF: 10 Hz, duration: 1 min with a 30 s interval) to the right hippocampus of twenty-six (n = 26) mice in vivo through intact scalp and skull. T1 and T2-weighted MR images were used to verify the BBB opening. A spectrogram was generated at each pressure in order to detect the IC onset and duration. The threshold of BBB opening was found to be at a 0.30 MPa peak-rarefactional pressure in vivo. Both the phantom and in vivo studies indicated that the IC pressure threshold had a peak-rarefactional amplitude of 0.45 MPa. This indicated that BBB opening may not require IC at or near the threshold. Histological analysis showed that BBB opening could be induced without any cellular damage at 0.30 and 0.45 MPa. In conclusion, the cavitation response could be detected

  12. Novel fiber optic sensor probe with a pair of highly reflected connectors and a vessel of water absorption material for water leak detection.

    Science.gov (United States)

    Cho, Tae-Sik; Choi, Ki-Sun; Seo, Dae-Cheol; Kwon, Il-Bum; Lee, Jung-Ryul

    2012-01-01

    The use of a fiber optic quasi-distributed sensing technique for detecting the location and severity of water leakage is suggested. A novel fiber optic sensor probe is devised with a vessel of water absorption material called as water combination soil (WCS) located between two highly reflected connectors: one is a reference connector and the other is a sensing connector. In this study, the sensing output is calculated from the reflected light signals of the two connectors. The first reflected light signal is a reference and the second is a sensing signal which is attenuated by the optical fiber bending loss due to the WCS expansion absorbing water. Also, the bending loss of each sensor probe is determined by referring to the total number of sensor probes and the total power budget of an entire system. We have investigated several probe characteristics to show the design feasibility of the novel fiber sensor probe. The effects of vessel sizes of the probes on the water detection sensitivity are studied. The largest vessel probe provides the highest sensitivity of 0.267 dB/mL, while the smallest shows relatively low sensitivity of 0.067 dB/mL, and unstable response. The sensor probe with a high output value provides a high sensitivity with various detection levels while the number of total installable sensor probes decreases.

  13. Novel Fiber Optic Sensor Probe with a Pair of Highly Reflected Connectors and a Vessel of Water Absorption Material for Water Leak Detection

    Directory of Open Access Journals (Sweden)

    Tae-Sik Cho

    2012-08-01

    Full Text Available The use of a fiber optic quasi-distributed sensing technique for detecting the location and severity of water leakage is suggested. A novel fiber optic sensor probe is devised with a vessel of water absorption material called as water combination soil (WCS located between two highly reflected connectors: one is a reference connector and the other is a sensing connector. In this study, the sensing output is calculated from the reflected light signals of the two connectors. The first reflected light signal is a reference and the second is a sensing signal which is attenuated by the optical fiber bending loss due to the WCS expansion absorbing water. Also, the bending loss of each sensor probe is determined by referring to the total number of sensor probes and the total power budget of an entire system. We have investigated several probe characteristics to show the design feasibility of the novel fiber sensor probe. The effects of vessel sizes of the probes on the water detection sensitivity are studied. The largest vessel probe provides the highest sensitivity of 0.267 dB/mL, while the smallest shows relatively low sensitivity of 0.067 dB/mL, and unstable response. The sensor probe with a high output value provides a high sensitivity with various detection levels while the number of total installable sensor probes decreases.

  14. Detection of Intracellular Factor VIII Protein in Peripheral Blood Mononuclear Cells by Flow Cytometry

    Directory of Open Access Journals (Sweden)

    Gouri Shankar Pandey

    2013-01-01

    Full Text Available Flow cytometry is widely used in cancer research for diagnosis, detection of minimal residual disease, as well as immune monitoring and profiling following immunotherapy. Detection of specific host proteins for diagnosis predominantly uses quantitative PCR and western blotting assays. In this study, we optimized a flow cytometry-based detection assay for Factor VIII protein in peripheral blood mononuclear cells (PBMCs. An indirect intracellular staining (ICS method was standardized using monoclonal antibodies to different domains of human Factor VIII protein. The FVIII protein expression level was estimated by calculating the mean and median fluorescence intensities (MFI values for each monoclonal antibody. ICS staining of transiently transfected cell lines supported the method's specificity. Intracellular FVIII protein expression was also detected by the monoclonal antibodies used in the study in PBMCs of five blood donors. In summary, our data suggest that intracellular FVIII detection in PBMCs of hemophilia A patients can be a rapid and reliable method to detect intracellular FVIII levels.

  15. A simple DNA coprecipitation method for the detection of diatoms in heart blood.

    Science.gov (United States)

    Seo, Yasuhisa; Sato, Shingo; Kuroki, Kohji; Kishida, Tetsuko

    2013-10-10

    We developed a method for detecting and enumerating diatoms in the heart blood of drowning victims and evaluate its utility for diagnosing death by drowning. For purification of diatoms from blood, the DNA binding ability of the diatom frustule in the presence of a chaotropic agent was utilized. The procedure is basically the same as the commonly used method for DNA purification from blood using Proteinase K treatment and denaturation by a chaotropic agent. DNA adsorbed to the diatom (DNA/diatom complex) is recovered by ethanol precipitation, and the DNA is subsequently digested using DNase. Purified diatoms could be clearly observed under a microscope. Diatoms spiked in the blood of non-drowned cadavers (n=15) were well recovered, and were detected in heart blood from all drowning victims (n=22). The mean number of diatoms found in 5 ml of blood from drowning victims was 7.8±5.8 (mean±SD), and the number of diatoms detected in the blood of the left ventricle (6.1±5.8) was approximately two times higher than that of the right ventricle (3.0±2.7, p<0.05). These results suggest that this simple and safe method can become an effective tool for diagnosing the cause of death as drowning. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Cerebral ischemia produced by four-vessel occlusion in the rat: a quantitative evaluation of cerebral blood flow

    International Nuclear Information System (INIS)

    Furlow, T.W. Jr.

    1982-01-01

    Cerebral ischemia was produced in the rat by simultaneous occlusion of the vertebral and carotid arteries according to the method of Pulsinelli and Brierley (Stroke 10: 267, 1979). Local cerebral blood flow (CBF) was determined by polarographic and autoradiographic techniques. Hydrogen-clearance measurements showed that mean CBF fell in four monitored regions of the hemispheres to between 0.11 and 0.18 ml/g/min, being least in deep rostal gray, intermediate in superficial gray, and greatest in deep caudal gray. However, individual animals had local CBF in excess of 0.20 and even 0.30 ml/g/min, and no animal showed zero CBF. When animals were rendered hypotensive (MABP of 50 Torr) during vascular occlusion, mean CBF ranged between 0.03 and 0.10 ml/g/min in the same regional order. With hypotension, total arrest of flow occurred. Autoradiographic data confirmed the above findings and indicated adequate CBF to the lower brainstem. During vascular occlusion, sufficient CBF may be present ot sustain cerebral tissue as in animals with a well developed spinal circulation or an inadvertently patent vertebral artery

  17. Cerebral ischemia produced by four-vessel occlusion in the rat: a quantitative evaluation of cerebral blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Furlow, T.W. Jr.

    Cerebral ischemia was produced in the rat by simultaneous occlusion of the vertebral and carotid arteries according to the method of Pulsinelli and Brierley (Stroke 10: 267, 1979). Local cerebral blood flow (CBF) was determined by polarographic and autoradiographic techniques. Hydrogen-clearance measurements showed that mean CBF fell in four monitored regions of the hemispheres to between 0.11 and 0.18 ml/g/min, being least in deep rostal gray, intermediate in superficial gray, and greatest in deep caudal gray. However, individual animals had local CBF in excess of 0.20 and even 0.30 ml/g/min, and no animal showed zero CBF. When animals were rendered hypotensive (MABP of 50 Torr) during vascular occlusion, mean CBF ranged between 0.03 and 0.10 ml/g/min in the same regional order. With hypotension, total arrest of flow occurred. Autoradiographic data confirmed the above findings and indicated adequate CBF to the lower brainstem. During vascular occlusion, sufficient CBF may be present ot sustain cerebral tissue as in animals with a well developed spinal circulation or an inadvertently patent vertebral artery.

  18. Superiority of West Nile Virus RNA Detection in Whole Blood for Diagnosis of Acute Infection.

    Science.gov (United States)

    Lustig, Yaniv; Mannasse, Batya; Koren, Ravit; Katz-Likvornik, Shiri; Hindiyeh, Musa; Mandelboim, Michal; Dovrat, Sara; Sofer, Danit; Mendelson, Ella

    2016-09-01

    The current diagnosis of West Nile virus (WNV) infection is primarily based on serology, since molecular identification of WNV RNA is unreliable due to the short viremia and absence of detectable virus in cerebrospinal fluid (CSF). Recent studies have shown that WNV RNA can be detected in urine for a longer period and at higher concentrations than in plasma. In this study, we examined the presence of WNV RNA in serum, plasma, whole-blood, CSF, and urine samples obtained from patients diagnosed with acute WNV infection during an outbreak which occurred in Israel in 2015. Our results demonstrate that 33 of 38 WNV patients had detectable WNV RNA in whole blood at the time of diagnosis, a higher rate than in any of the other sample types tested. Overall, whole blood was superior to all other samples, with 86.8% sensitivity, 100% specificity, 100% positive predictive value, and 83.9% negative predictive value. Interestingly, WNV viral load in urine was higher than in whole blood, CSF, serum, and plasma despite the lower sensitivity than that of whole blood. This study establishes the utility of whole blood in the routine diagnosis of acute WNV infection and suggests that it may provide the highest sensitivity for WNV RNA detection in suspected cases. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  19. Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

    Science.gov (United States)

    Murray, P R

    1991-01-01

    Although the detection of fungemia has been improved by the use of vented or biphasic blood culture bottles, the best recovery and earliest detection have been reported in the Isolator lysis-centrifugation system. It was recently demonstrated that improved detection of both bacteria and fungi was accomplished by mechanically agitating blood culture bottles for the first 24 h of incubation. In this study the detection of fungemia by use of the Isolator system was compared with that of an agitated biphasic system. A total of 182 fungi were isolated from blood specimens inoculated into both culture systems. No difference in the overall recovery of fungi or individual species of yeasts was observed between the two systems. However, all seven isolates of Histoplasma capsulatum were recovered in the Isolator system only. The time required to detect fungemia with each of the two systems was also compared. No statistically significant difference was observed. From the data collected during this 18-month study, it can be concluded that the overall recovery and time of detection of yeasts are equivalent in the lysis-centrifugation system and the agitated biphasic blood culture system. The lysis-centrifugation system is still superior for the detection of filamentous fungi such as H. capsulatum. PMID:1993772

  20. Thermographic venous blood flow characterization with external cooling stimulation

    Science.gov (United States)

    Saxena, Ashish; Ng, E. Y. K.; Raman, Vignesh

    2018-05-01

    Experimental characterization of blood flow in a human forearm is done with the application of continuous external cooling based active thermography method. Qualitative and quantitative detection of the blood vessel in a thermal image is done, along with the evaluation of blood vessel diameter, blood flow direction, and velocity in the target blood vessel. Subtraction based image manipulation is performed to enhance the feature contrast of the thermal image acquired after the removal of external cooling. To demonstrate the effect of occlusion diseases (obstruction), an external cuff based occlusion is applied after the removal of cooling and its effect on the skin rewarming is studied. Using external cooling, a transit time method based blood flow velocity estimation is done. From the results obtained, it is evident that an external cooling based active thermography method can be used to develop a diagnosis tool for superficial blood vessel diseases.

  1. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    Energy Technology Data Exchange (ETDEWEB)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille [Caen University Hospital, Department of Internal Medicine, Caen (France); Liozon, Eric; Ly, Kim Heang [Limoges University Hospital, Department of Internal Medicine, Limoges (France); Lambert, Marc [Lille University Hospital, Department of Internal Medicine, Lille (France); Aide, Nicolas [Caen University Hospital, Department of Nuclear Medicine, Caen (France); INSERM U1086 ' ' ANTICIPE' ' , Francois Baclesse Cancer Centre, Caen (France); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Caen (France); Normandy University, Caen (France)

    2017-12-15

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  2. Functional and pharmacological consequences of the distribution of voltage-gated calcium channels in the renal blood vessels.

    Science.gov (United States)

    Hansen, P B L

    2013-04-01

    Calcium channel blockers are widely used to treat hypertension because they inhibit voltage-gated calcium channels that mediate transmembrane calcium influx in, for example, vascular smooth muscle and cardiomyocytes. The calcium channel family consists of several subfamilies, of which the L-type is usually associated with vascular contractility. However, the L-, T- and P-/Q-types of calcium channels are present in the renal vasculature and are differentially involved in controlling vascular contractility, thereby contributing to regulation of kidney function and blood pressure. In the preglomerular vascular bed, all the three channel families are present. However, the T-type channel is the only channel in cortical efferent arterioles which is in contrast to the juxtamedullary efferent arteriole, and that leads to diverse functional effects of L- and T-type channel inhibition. Furthermore, by different mechanisms, T-type channels may contribute to both constriction and dilation of the arterioles. Finally, P-/Q-type channels are involved in the regulation of human intrarenal arterial contractility. The calcium blockers used in the clinic affect not only L-type but also P-/Q- and T-type channels. Therefore, the distinct effect obtained by inhibiting a given subtype or set of channels under experimental settings should be considered when choosing a calcium blocker for treatment. T-type channels seem to be crucial for regulating the GFR and the filtration fraction. Use of blockers is expected to lead to preferential efferent vasodilation, reduction of glomerular pressure and proteinuria. Therefore, renovascular T-type channels might provide novel therapeutic targets, and may have superior renoprotective effects compared to conventional calcium blockers. Acta Physiologica © 2013 Scandinavian Physiological Society.

  3. [Detection of Candida DNA in simulated blood samples by polymerase chain reaction].

    Science.gov (United States)

    Ozer, Sinem; Yücesoy, Mine

    2007-07-01

    Although blood culture method is accepted as gold standard in the laboratory diagnosis of invasive candidiasis seen in immunocompromised patients, cultivation of blood is considered as not a reliable and rapid method for the diagnosis of candidemia, since it may be negative in approximately half of the patients, slow growth rate of Candida in routine culture media and requirement of large amounts of blood for the isolation. The aim of this study was to detect Candida DNA in simulated blood samples by using polymerase chain reaction (PCR). Simulated samples were prepared by using blood samples of healthy