WorldWideScience

Sample records for blood processing system

  1. A portable system for processing donated whole blood into high quality components without centrifugation.

    Science.gov (United States)

    Gifford, Sean C; Strachan, Briony C; Xia, Hui; Vörös, Eszter; Torabian, Kian; Tomasino, Taylor A; Griffin, Gary D; Lichtiger, Benjamin; Aung, Fleur M; Shevkoplyas, Sergey S

    2018-01-01

    The use of centrifugation-based approaches for processing donated blood into components is routine in the industrialized world, as disparate storage conditions require the rapid separation of 'whole blood' into distinct red blood cell (RBC), platelet, and plasma products. However, the logistical complications and potential cellular damage associated with centrifugation/apheresis manufacturing of blood products are well documented. The objective of this study was to evaluate a proof-of-concept system for whole blood processing, which does not employ electromechanical parts, is easily portable, and can be operated immediately after donation with minimal human labor. In a split-unit study (n = 6), full (~500mL) units of freshly-donated whole blood were divided, with one half processed by conventional centrifugation techniques and the other with the new blood separation system. Each of these processes took 2-3 hours to complete and were performed in parallel. Blood products generated by the two approaches were compared using an extensive panel of cellular and plasma quality metrics. Comparison of nearly all RBC parameters showed no significant differences between the two approaches, although the portable system generated RBC units with a slight but statistically significant improvement in 2,3-diphosphoglyceric acid concentration (p applications in remote or resource-limited settings, or for patients requiring highly functional platelet product.

  2. 21 CFR 864.9145 - Processing system for frozen blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Processing system for frozen blood. 864.9145 Section 864.9145 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  3. Bottlenecks of blood processing in Uganda

    NARCIS (Netherlands)

    Kajja, I.; Kyeyune, D.; Bimenya, G. S.; Sibinga, C. T. S.

    2010-01-01

    Aim: To identify where and why delays occur in Uganda blood banks. Background: The timely provision and supply of safe and efficacious blood components to hospitals depends on sound systems in the processing blood banks. Poorly managed systems lead to apparent blood shortages in hospitals and

  4. Automated processing of whole blood units: operational value and in vitro quality of final blood components.

    Science.gov (United States)

    Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz

    2012-01-01

    The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement.

  5. Designing an automated blood fractionation system.

    Science.gov (United States)

    McQuillan, Adrian C; Sales, Sean D

    2008-04-01

    UK Biobank will be collecting blood samples from a cohort of 500 000 volunteers and it is expected that the rate of collection will peak at approximately 3000 blood collection tubes per day. These samples need to be prepared for long-term storage. It is not considered practical to manually process this quantity of samples so an automated blood fractionation system is required. Principles of industrial automation were applied to the blood fractionation process leading to the requirement of developing a vision system to identify the blood fractions within the blood collection tube so that the fractions can be accurately aspirated and dispensed into micro-tubes. A prototype was manufactured and tested on a range of human blood samples collected in different tube types. A specially designed vision system was capable of accurately measuring the position of the plasma meniscus, plasma/buffy coat interface and the red cells/buffy coat interface within a vacutainer. A rack of 24 vacutainers could be processed in blood fractionation system offers a solution to the problem of processing human blood samples collected in vacutainers in a consistent manner and provides a means of ensuring data and sample integrity.

  6. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cord blood processing system and storage container. 864.9900 Section 864.9900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That...

  7. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: gas@cdtn.br, e-mail: pls@cdtn.br, e-mail: fcp@cdtn.br, e-mail: lcmb@cdtn.br, e-mail: pabloag@cdtn.br

    2009-07-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  8. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    International Nuclear Information System (INIS)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade

    2009-01-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  9. Duffy blood group system and the malaria adaptation process in humans

    Directory of Open Access Journals (Sweden)

    Gledson Barbosa de Carvalho

    2011-02-01

    Full Text Available Malaria is an acute infectious disease caused by the protozoa of the genus Plasmodium. The antigens of the Duffy Blood Group System, in addition to incompatibilities in transfusions and hemolytic disease of the newborn, are of great interest in medicine due to their association with the invasion of red blood cells by the parasite Plasmodium vivax. For invasions to occur an interaction between the parasites and antigens of the Duffy Blood Group System is necessary. In Caucasians six antigens are produced by the Duffy locus (Fya, Fyb, F3, F4, F5 and F6. It has been observed that Fy(a-b- individuals are resistant to Plasmodium knowlesi and P. vivax infection, because the invasion requires at least one of these antigens. The P. vivax Duffy Binding Protein (PvDBP is functionally important in the invasion process of these parasites in Duffy / DARC positive humans. The proteins or fractions may be considered, therefore, an important and potential inoculum to be used in immunization against malaria.

  10. Impact of blood collection and processing on peripheral blood gene expression profiling in type 1 diabetes.

    Science.gov (United States)

    Yip, Linda; Fuhlbrigge, Rebecca; Atkinson, Mark A; Fathman, C Garrison

    2017-08-18

    The natural history of type 1 diabetes (T1D) is challenging to investigate, especially as pre-diabetic individuals are difficult to identify. Numerous T1D consortia have been established to collect whole blood for gene expression analysis from individuals with or at risk to develop T1D. However, with no universally accepted protocol for their collection, differences in sample processing may lead to variances in the results. Here, we examined whether the choice of blood collection tube and RNA extraction kit leads to differences in the expression of genes that are changed during the progression of T1D, and if these differences could be minimized by measuring gene expression directly from the lysate of whole blood. Microarray analysis showed that the expression of 901 genes is highly influenced by sample processing using the PAXgene versus the Tempus system. These included a significant number of lymphocyte-specific genes and genes whose expression has been reported to differ in the peripheral blood of at-risk and T1D patients compared to controls. We showed that artificial changes in gene expression occur when control and T1D samples were processed differently. The sample processing-dependent differences in gene expression were largely due to loss of transcripts during the RNA extraction step using the PAXgene system. The majority of differences were not observed when gene expression was measured in whole blood lysates prepared from blood collected in PAXgene and Tempus tubes. We showed that the gene expression profile of samples processed using the Tempus system is more accurate than that of samples processed using the PAXgene system. Variation in sample processing can result in misleading changes in gene expression. However, these differences can be minimized by measuring gene expression directly in whole blood lysates.

  11. Perioperative blood ordering optimization process using information from an anesthesia information management system.

    Science.gov (United States)

    Rinehart, Joseph B; Lee, Tiffany C; Kaneshiro, Kayleigh; Tran, Minh-Ha; Sun, Coral; Kain, Zeev N

    2016-04-01

    As part of ongoing perioperative surgical home implantation process, we applied a previously published algorithm for creation of a maximum surgical blood order schedule (MSBOS) to our operating rooms. We hypothesized that using the MSBOS we could show a reduction in unnecessary preoperative blood testing and associated costs. Data regarding all surgical cases done at UC Irvine Health's operating rooms from January 1, 2011, to January 1, 2014 were extracted from the anesthesia information management systems (AIMS). After the data were organized into surgical specialties and operative sites, blood order recommendations were generated based on five specific case characteristics of the group. Next, we assessed current ordering practices in comparison to actual blood utilization to identify potential areas of wastage and performed a cost analysis comparing the annual hospital costs from preoperative blood orders if the blood order schedule were to be followed to historical practices. Of the 19,138 patients who were categorized by the MSBOS as needing no blood sample, 2694 (14.0%) had a type and screen (T/S) ordered and 1116 (5.8%) had a type and crossmatch ordered. Of the 6073 procedures where MSBOS recommended only a T/S, 2355 (38.8%) had blood crossmatched. The cost analysis demonstrated an annual reduction in actual hospital costs of $57,335 with the MSBOS compared to historical blood ordering practices. We showed that the algorithm for development of a multispecialty blood order schedule is transferable and yielded reductions in preoperative blood product screening at our institution. © 2016 AABB.

  12. Processing and storage of blood components: strategies to improve patient safety

    Directory of Open Access Journals (Sweden)

    Pietersz RNI

    2015-08-01

    Full Text Available Ruby NI Pietersz, Pieter F van der Meer Department of Product and Process Development, Sanquin Blood Bank, Amsterdam, the Netherlands Abstract: This review focuses on safety improvements of blood processing of various blood components and their respective storage. A solid quality system to ensure safe and effective blood components that are traceable from a donor to the patient is the foundation of a safe blood supply. To stimulate and guide this process, National Health Authorities should develop guidelines for blood transfusion, including establishment of a quality system. Blood component therapy enabled treatment of patients with blood constituents that were missing, only thus preventing reactions to unnecessarily transfused elements. Leukoreduction prevents many adverse reactions and also improves the quality of the blood components during storage. The safety of red cells and platelets is improved by replacement of plasma with preservative solutions, which results in the reduction of isoantibodies and plasma proteins. Automation of blood collection, separation of whole blood into components, and consecutive processing steps, such as preparation of platelet concentrate from multiple donations, improves the consistent composition of blood components. Physicians can better prescribe the number of transfusions and therewith reduce donor exposure and/or the risk of pathogen transmission. Pathogen reduction in cellular blood components is the latest development in improving the safety of blood transfusions for patients. Keywords: blood components, red cell concentrates, platelet concentrates, plasma, transfusion, safety 

  13. Intelligent micro blood typing system using a fuzzy algorithm

    International Nuclear Information System (INIS)

    Kang, Taeyun; Cho, Dong-Woo; Lee, Seung-Jae; Kim, Yonggoo; Lee, Gyoo-Whung

    2010-01-01

    ABO typing is the first analysis performed on blood when it is tested for transfusion purposes. The automated machines used in hospitals for this purpose are typically very large and the process is complicated. In this paper, we present a new micro blood typing system that is an improved version of our previous system (Kang et al 2004 Trans. ASME, J. Manuf. Sci. Eng. 126 766, Lee et al 2005 Sensors Mater. 17 113). This system, fabricated using microstereolithography, has a passive valve for controlling the flow of blood and antibodies. The intelligent micro blood typing system has two parts: a single-line micro blood typing device and a fuzzy expert system for grading the strength of agglutination. The passive valve in the single-line micro blood typing device makes the blood stop at the entrance of a micro mixer and lets it flow again after the blood encounters antibodies. Blood and antibodies are mixed in the micro mixer and agglutination occurs in the chamber. The fuzzy expert system then determines the degree of agglutination from images of the agglutinated blood. Blood typing experiments using this device were successful, and the fuzzy expert system produces a grading decision comparable to that produced by an expert conducting a manual analysis

  14. Influence of the washing program on the blood processing performance of a continuous autotransfusion device.

    Science.gov (United States)

    Yoon, Chiyul; Noh, Seungwoo; Lee, Jung Chan; Ko, Sung Ho; Ahn, Wonsik; Kim, Hee Chan

    2014-03-01

    The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.

  15. Blood as integral system of an organism

    Directory of Open Access Journals (Sweden)

    Майя Розметовна Верголяс

    2016-02-01

    Full Text Available Relevance of use of hematological blood parameters for monitoring as markers of various physiological and pathological processes is substantiated. It is shown that the blood is an important system of the body, has all the reactive characteristics of tissues, its sensitivity to pathological stimuli is very high. The reaction of the organism to the irritation of toxic or infectious nature manifests itself in the change of quantitative composition of peripheral blood cells

  16. The effect of increased centrifugation temperature on the quality of red-blood-cell concentrates of automated whole blood processing.

    Science.gov (United States)

    Weinigel, C; Rummler, S; Barz, D

    2013-10-01

    There are manual and automated methods to separate whole blood (WB) available. The Atreus whole blood processing system is an automated method, which combines centrifugation and expression of components into a single device. A major difference to conventional methods is that centrifugation temperature is not controlled at 22°C. The aim of this study was to examine the influence of increased centrifugation temperatures on the quality of red-blood-cell concentrates (RCC) after active cooling of WB prior to processing. A total of 28 WB were processed: 16 at centrifugation temperatures of up to 28°C (1st protocol) and 12 at 34°C (2nd protocol). RCC quality parameters were tested weekly for 42 days. Red-blood-cell concentrates (RCC) quality complied with the European and German guidelines. Haemolysis was not significantly different throughout storage. Significant statistical differences were detected between both protocols in potassium concentration at the end of storage and in ATP levels at the day of processing. Centrifugation temperatures of up to 34°C are well tolerated by the red blood cells with minimal interference with the RCC quality parameters. © 2013 International Society of Blood Transfusion.

  17. Blood-brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood-central nervous system interface.

    Science.gov (United States)

    Phan, Duc Tt; Bender, R Hugh F; Andrejecsk, Jillian W; Sobrino, Agua; Hachey, Stephanie J; George, Steven C; Hughes, Christopher Cw

    2017-11-01

    The blood-brain barrier is a dynamic and highly organized structure that strictly regulates the molecules allowed to cross the brain vasculature into the central nervous system. The blood-brain barrier pathology has been associated with a number of central nervous system diseases, including vascular malformations, stroke/vascular dementia, Alzheimer's disease, multiple sclerosis, and various neurological tumors including glioblastoma multiforme. There is a compelling need for representative models of this critical interface. Current research relies heavily on animal models (mostly mice) or on two-dimensional (2D) in vitro models, neither of which fully capture the complexities of the human blood-brain barrier. Physiological differences between humans and mice make translation to the clinic problematic, while monolayer cultures cannot capture the inherently three-dimensional (3D) nature of the blood-brain barrier, which includes close association of the abluminal side of the endothelium with astrocyte foot-processes and pericytes. Here we discuss the central nervous system diseases associated with blood-brain barrier pathology, recent advances in the development of novel 3D blood-brain barrier -on-a-chip systems that better mimic the physiological complexity and structure of human blood-brain barrier, and provide an outlook on how these blood-brain barrier-on-a-chip systems can be used for central nervous system disease modeling. Impact statement The field of microphysiological systems is rapidly evolving as new technologies are introduced and our understanding of organ physiology develops. In this review, we focus on Blood-Brain Barrier (BBB) models, with a particular emphasis on how they relate to neurological disorders such as Alzheimer's disease, multiple sclerosis, stroke, cancer, and vascular malformations. We emphasize the importance of capturing the three-dimensional nature of the brain and the unique architecture of the BBB - something that until recently

  18. One System for Blood Program Information Management

    Science.gov (United States)

    Gero, Michael G.; Klickstein, Judith S.; Hurst, Timm M.

    1980-01-01

    A system which integrates the diverse functions of a Blood Program within one structure is being assembled at the American National Red Cross Blood Services, Northeast Region. When finished, it will provide technical support for collection scheduling, donor recruitment, recordkeeping, laboratory processing, inventory management, HLA typing and matching, distribution, and administration within the Program. By linking these applications, a reporting structure useful to top management will be provided.

  19. Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting

    Directory of Open Access Journals (Sweden)

    Xiwei Huang

    2016-11-01

    Full Text Available A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT. However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR and Convolutional Neural Network based SR (CNNSR. Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications.

  20. Point-of-care, portable microfluidic blood analyzer system

    Science.gov (United States)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  1. New approach to 'top-and-bottom' whole blood separation using the multiunit TACSI WB system: quality of blood components.

    Science.gov (United States)

    Lotens, A; Najdovski, T; Cellier, N; Ernotte, B; Lambermont, M; Rapaille, A

    2014-10-01

    TACSI whole blood system is designed to combine primary and secondary processing of six whole blood bags into plasma units, buffy coat and red blood cell concentrates. The aim of this study was to investigate the specifications and in vitro storage parameters of blood components compared with standard centrifugation and separation processing. Whole blood bags, collected in CRC kits, were treated on a TACSI whole blood system. They were compared with whole blood bags collected in Composelect kits. In addition to routine quality control analyses, conservation studies were performed on red blood cell concentrates for 42 days and on plasma for 6 months. Platelets pools with five buffy coats were also created, and cellular contamination was evaluated. Red blood cell concentrates produced from TACSI whole blood met European quality requirements. For white blood cell count, one individual result exceeded 1 × 10(6) cells/unit. All plasma units fell within specifications for residual cellular contamination and storage parameters. The performances of the TACSI whole blood system allow for the preparation of low volume buffy coats with a recovery of 90% of whole blood platelets. Haemoglobin losses in TACSI BC are smaller, but this did not result in higher haemoglobin content of red cells. These BC are suitable for the production of platelet concentrates. From these in vitro data, red blood cell concentrates produced using TACSI whole blood are suitable for clinical use with a quality at least equivalent to the control group. © 2014 International Society of Blood Transfusion.

  2. Good manufacturing practices (GMP utilized on human blood irradiation process

    Directory of Open Access Journals (Sweden)

    Cláudio Boghi

    2008-01-01

    Full Text Available Irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease, a rare but devastating adverse effect of leukocytes present in blood components for immunocompetent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of lymphocytes. The implementation of the GMP will assure that the properly dose in a range of 25Gy to 50Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies to establish the GMP were developed under the guidelines of the standard ISO 11137 - Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO4: Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, trace ability and calibration system. The PMMA and gafchromic dosimetric systems have shown a better performance and were adopted on establishment of GMP procedures. The irradiation tests have been done using a Gammacell 220 Irradiator. The developed GMP can be adapted for different types of gamma irradiators, allowing to set up a quality assurance program for blood irradiation.

  3. Modeling and simulation of blood collection systems.

    Science.gov (United States)

    Alfonso, Edgar; Xie, Xiaolan; Augusto, Vincent; Garraud, Olivier

    2012-03-01

    This paper addresses the modeling and simulation of blood collection systems in France for both fixed site and mobile blood collection with walk in whole blood donors and scheduled plasma and platelet donors. Petri net models are first proposed to precisely describe different blood collection processes, donor behaviors, their material/human resource requirements and relevant regulations. Petri net models are then enriched with quantitative modeling of donor arrivals, donor behaviors, activity times and resource capacity. Relevant performance indicators are defined. The resulting simulation models can be straightforwardly implemented with any simulation language. Numerical experiments are performed to show how the simulation models can be used to select, for different walk in donor arrival patterns, appropriate human resource planning and donor appointment strategies.

  4. Computational simulation of the blood separation process.

    Science.gov (United States)

    De Gruttola, Sandro; Boomsma, Kevin; Poulikakos, Dimos; Ventikos, Yiannis

    2005-08-01

    The aim of this work is to construct a computational fluid dynamics model capable of simulating the quasitransient process of apheresis. To this end a Lagrangian-Eulerian model has been developed which tracks the blood particles within a delineated two-dimensional flow domain. Within the Eulerian method, the fluid flow conservation equations within the separator are solved. Taking the calculated values of the flow field and using a Lagrangian method, the displacement of the blood particles is calculated. Thus, the local blood density within the separator at a given time step is known. Subsequently, the flow field in the separator is recalculated. This process continues until a quasisteady behavior is reached. The simulations show good agreement with experimental results. They shows a complete separation of plasma and red blood cells, as well as nearly complete separation of red blood cells and platelets. The white blood cells build clusters in the low concentrate cell bed.

  5. Evaluation of the antimicrobial removal device when used with the BACTEC blood culture system

    International Nuclear Information System (INIS)

    Strand, C.L.

    1982-01-01

    A study to determine the value of the Antimicrobial Removal Device (ARD) used in conjunction with radiometric detection of bacteremia using three media was conducted. During a 12-month period, 622 duplicate ARD/BACTEC blood-culture sets were collected. There were 88 positive cultures that yielded 68 pathogenic isolates and 28 probable contaminant isolates. When all patients were considered, 31 pathogenic isolates were detected by both systems, 25 pathogenic isolates were detected faster or only by the BACTEC system, and 12 pathogenic isolates were detected faster or only when the ARD was employed. This difference is statistically significant (P less than 0.05). Thus, the standard BACTEC blood-culture system using three different media was superior to the same BACTEC system using ARD-processed blood specimens. When only patients receiving antimicrobial therapy were considered, there were more pathogenic isolates detected from unprocessed blood than from blood processed in the ARD; however, this difference was not statistically significant. In conclusion, there appears to be no advantage to using the ARD system in conjunction with the three-bottle BACTEC blood-culture system

  6. A Gaussian process and derivative spectral-based algorithm for red blood cell segmentation

    Science.gov (United States)

    Xue, Yingying; Wang, Jianbiao; Zhou, Mei; Hou, Xiyue; Li, Qingli; Liu, Hongying; Wang, Yiting

    2017-07-01

    As an imaging technology used in remote sensing, hyperspectral imaging can provide more information than traditional optical imaging of blood cells. In this paper, an AOTF based microscopic hyperspectral imaging system is used to capture hyperspectral images of blood cells. In order to achieve the segmentation of red blood cells, Gaussian process using squared exponential kernel function is applied first after the data preprocessing to make the preliminary segmentation. The derivative spectrum with spectral angle mapping algorithm is then applied to the original image to segment the boundary of cells, and using the boundary to cut out cells obtained from the Gaussian process to separated adjacent cells. Then the morphological processing method including closing, erosion and dilation is applied so as to keep adjacent cells apart, and by applying median filtering to remove noise points and filling holes inside the cell, the final segmentation result can be obtained. The experimental results show that this method appears better segmentation effect on human red blood cells.

  7. Blood Donation Process

    Science.gov (United States)

    ... Drive Biomedical Services Hospital Partners Blood Products Blood Banking Resources Order Blood Products Invoice Central Case Reports ... Speed up your donation by completing a RapidPass® online or on the Blood Donor app on the ...

  8. SBR-Blood: systems biology repository for hematopoietic cells.

    Science.gov (United States)

    Lichtenberg, Jens; Heuston, Elisabeth F; Mishra, Tejaswini; Keller, Cheryl A; Hardison, Ross C; Bodine, David M

    2016-01-04

    Extensive research into hematopoiesis (the development of blood cells) over several decades has generated large sets of expression and epigenetic profiles in multiple human and mouse blood cell types. However, there is no single location to analyze how gene regulatory processes lead to different mature blood cells. We have developed a new database framework called hematopoietic Systems Biology Repository (SBR-Blood), available online at http://sbrblood.nhgri.nih.gov, which allows user-initiated analyses for cell type correlations or gene-specific behavior during differentiation using publicly available datasets for array- and sequencing-based platforms from mouse hematopoietic cells. SBR-Blood organizes information by both cell identity and by hematopoietic lineage. The validity and usability of SBR-Blood has been established through the reproduction of workflows relevant to expression data, DNA methylation, histone modifications and transcription factor occupancy profiles. Published by Oxford University Press on behalf of Nucleic Acids Research 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  9. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  10. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood gases (PCO2, PO2) and blood pH test system... Test Systems § 862.1120 Blood gases (PCO2, PO2) and blood pH test system. (a) Identification. A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum...

  11. An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System.

    Science.gov (United States)

    George, Paul E; Vidal, Julio; Garcia, Patricia J

    2016-05-01

    Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Every Peruvian blood bank was evaluated by MINSA from 2007-2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product.

  12. A RAPID Method for Blood Processing to Increase the Yield of Plasma Peptide Levels in Human Blood.

    Science.gov (United States)

    Teuffel, Pauline; Goebel-Stengel, Miriam; Hofmann, Tobias; Prinz, Philip; Scharner, Sophie; Körner, Jan L; Grötzinger, Carsten; Rose, Matthias; Klapp, Burghard F; Stengel, Andreas

    2016-04-28

    Research in the field of food intake regulation is gaining importance. This often includes the measurement of peptides regulating food intake. For the correct determination of a peptide's concentration, it should be stable during blood processing. However, this is not the case for several peptides which are quickly degraded by endogenous peptidases. Recently, we developed a blood processing method employing Reduced temperatures, Acidification, Protease inhibition, Isotopic exogenous controls and Dilution (RAPID) for the use in rats. Here, we have established this technique for the use in humans and investigated recovery, molecular form and circulating concentration of food intake regulatory hormones. The RAPID method significantly improved the recovery for (125)I-labeled somatostatin-28 (+39%), glucagon-like peptide-1 (+35%), acyl ghrelin and glucagon (+32%), insulin and kisspeptin (+29%), nesfatin-1 (+28%), leptin (+21%) and peptide YY3-36 (+19%) compared to standard processing (EDTA blood on ice, p processing, while after standard processing 62% of acyl ghrelin were degraded resulting in an earlier peak likely representing desacyl ghrelin. After RAPID processing the acyl/desacyl ghrelin ratio in blood of normal weight subjects was 1:3 compared to 1:23 following standard processing (p = 0.03). Also endogenous kisspeptin levels were higher after RAPID compared to standard processing (+99%, p = 0.02). The RAPID blood processing method can be used in humans, yields higher peptide levels and allows for assessment of the correct molecular form.

  13. Virtual blood bank

    Directory of Open Access Journals (Sweden)

    Kit Fai Wong

    2011-01-01

    Full Text Available Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time.

  14. Laser cutting eliminates nucleic acid cross-contamination in dried-blood-spot processing.

    Science.gov (United States)

    Murphy, Sean C; Daza, Glenda; Chang, Ming; Coombs, Robert

    2012-12-01

    Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing.

  15. 77 FR 46096 - Statistical Process Controls for Blood Establishments; Public Workshop

    Science.gov (United States)

    2012-08-02

    ...] Statistical Process Controls for Blood Establishments; Public Workshop AGENCY: Food and Drug Administration... workshop entitled: ``Statistical Process Controls for Blood Establishments.'' The purpose of this public workshop is to discuss the implementation of statistical process controls to validate and monitor...

  16. Whiteboard Icons to Support the Blood-Test Process in an Emergency Department

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten; From, Gustav

    2013-01-01

    The competent treatment of emergency department (ED) patients requires an effective and efficient process for handling laboratory tests such as blood tests. This study investigates how ED clinicians go about the process, from ordering blood tests to acknowledging their results and, specifically......, assesses the use of whiteboard icons to support this process. On the basis of observation and interviews we find that the blood-test process is intertwined with multiple other temporal patterns in ED work. The whiteboard icons, which indicate four temporally distinct steps in the blood-test process......, support the nurses in maintaining the flow of patients through the ED and the physicians in assessing test results at timeouts. The main results of this study are, however, that the blood-test process is temporally and collaboratively complex, that the whiteboard icons pass by most of this complexity...

  17. Coded excitation and sub-band processing for blood velocity estmation in medical ultrasound

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Jensen, Jørgen Arendt

    2007-01-01

    This paper investigates the use of broadband coded excitation and subband processing for blood velocity estimation in medical ultrasound. In conventional blood velocity estimation a long (narrow-band) pulse is emitted and the blood velocity is estimated using an auto-correlation based approach....... However, the axial resolution of the narrow-band pulse is too poor for brightness-mode (B-mode) imaging. Therefore, a separate transmission sequence is used for updating the B-mode image, which lowers the overall frame-rate of the system. By using broad-band excitation signals, the backscattered received...... signal can be divided into a number of narrow frequency bands. The blood velocity can be estimated in each of the bands and the velocity estimates can be averaged to form an improved estimate. Furthermore, since the excitation signal is broadband, no secondary B-mode sequence is required, and the frame...

  18. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  19. Use of statistical process control in the production of blood components

    DEFF Research Database (Denmark)

    Magnussen, K; Quere, S; Winkel, P

    2008-01-01

    Introduction of statistical process control in the setting of a small blood centre was tested, both on the regular red blood cell production and specifically to test if a difference was seen in the quality of the platelets produced, when a change was made from a relatively large inexperienced...... by an experienced staff with four technologists. We applied statistical process control to examine if time series of quality control values were in statistical control. Leucocyte count in red blood cells was out of statistical control. Platelet concentration and volume of the platelets produced by the occasional...... occasional component manufacturing staff to an experienced regular manufacturing staff. Production of blood products is a semi-automated process in which the manual steps may be difficult to control. This study was performed in an ongoing effort to improve the control and optimize the quality of the blood...

  20. Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry.

    Science.gov (United States)

    Vogeser, Michael; Spöhrer, Ute

    2006-01-01

    Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.

  1. On-chip sample preparation for complete blood count from raw blood.

    Science.gov (United States)

    Nguyen, John; Wei, Yuan; Zheng, Yi; Wang, Chen; Sun, Yu

    2015-03-21

    This paper describes a monolithic microfluidic device capable of on-chip sample preparation for both RBC and WBC measurements from whole blood. For the first time, on-chip sample processing (e.g. dilution, lysis, and filtration) and downstream single cell measurement were fully integrated to enable sample preparation and single cell analysis from whole blood on a single device. The device consists of two parallel sub-systems that perform sample processing and electrical measurements for measuring RBC and WBC parameters. The system provides a modular environment capable of handling solutions of various viscosities by adjusting the length of channels and precisely controlling mixing ratios, and features a new 'offset' filter configuration for increased duration of device operation. RBC concentration, mean corpuscular volume (MCV), cell distribution width, WBC concentration and differential are determined by electrical impedance measurement. Experimental characterization of over 100,000 cells from 10 patient blood samples validated the system's capability for performing on-chip raw blood processing and measurement.

  2. Influence of ionizing radiation and 12-crown-4 on coagulation system components of rat blood

    International Nuclear Information System (INIS)

    Kratenko, R.Yi.

    2006-01-01

    The influence of 12-crown-4 and ionizing radiation on some components of blood coagulation system: Ca 2+ contents and prostaglandin concentrations in the blood serum, and erythrocyte contents in the blood plasma are studied. The influence of 12-crown-4 and ionizing radiation increases the coagulational properties of erythrocytes. The synergism of ionizing irradiation and 12-crown-4 influence blood coagulation process points out at the occurrence of radiomimetic properties of the latter

  3. The circulatory system: blood procurement, AIDS, and the social body in China.

    Science.gov (United States)

    Erwin, Kathleen

    2006-06-01

    The market for blood thrived in China for more than a decade, preying on rural villagers desperate for cash. Profit motives and unhygienic collection created an AIDS epidemic, where now up to 80 percent of adults in some villages are HIV infected. Today, illegal blood banks continue to operate in some areas. Moreover, better screening and blood testing do little to address the underlying cultural reluctance to give blood. This article examines what is at stake for blood donors in the circulation of blood through both the physical and the social bodies in China today. I argue that public health and social policy solutions require consideration of the symbolic meanings of blood and the body, kin relations, and gift exchange. China's HIV-contaminated blood procurement crisis demands a critical reexamination of the hidden processes embedded in a "circulatory system" that has inseparably bound the "gift of life" and a "commodity of death".

  4. Quality evaluation of blood irradiation process;Avaliacao da qualidade do processo de irradiacao de hemocomponentes

    Energy Technology Data Exchange (ETDEWEB)

    Goto, R.E.; Medeiros, R.B. [Universidade Federal de Sao Paulo (DDI/UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem. Coordenadoria de Fisica e Higiene das Radiacoes

    2009-07-01

    An adverse reaction in blood transfusion is the graft versus host disease (GVHD). This disease affects immunodeficient or immunosuppressed patients where transfused T cells proliferate and initiate a host's immune system reaction. Blood gamma irradiation is the most efficient way to inhibit lymphocyte T blastic transformation and mitotic activity and it is the most effective method to combat this disorder. However, there is no fast and effective system to analyze the dose distribution in the irradiation process and guarantee that the absorbed doses are in agreement with FDA recommendations. This study aims to establish a periodic quality control of the gammacell irradiators using radiochromic films properly calibrated. The quality control is simply and effective to combat GVHD as well as is useful to detect mechanical fails at rotation set system through the dose uniformity analysis. It was possible to verify the uniformity ranged from -72.38% to 106.33% and some blood bag received doses not compatible with recommended international threshold. (author)

  5. Blood Conservation.

    Science.gov (United States)

    Martin, Jeremiah T; Ferraris, Victor A

    2015-01-01

    Patient blood management requires multi-modality and multidisciplinary collaboration to identify patients who are at increased risk of requiring blood transfusion and therefore decrease exposure to blood products. Transfusion is associated with poor postoperative outcomes, and guidelines exist to minimize transfusion requirements. This review highlights recent studies and efforts to apply patient blood management across disease processes and health care systems. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. 21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Empty container for the collection and processing of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products...

  7. Harvesting, processing and inventory management of peripheral blood stem cells

    Directory of Open Access Journals (Sweden)

    Mijovic Aleksandar

    2007-01-01

    Full Text Available By 2003, 97% autologous transplants and 65% of allogeneic transplants in Europe used mobilised peripheral blood stem cells (PBSC. Soon after their introduction in the early 1990′s, PBSC were associated with faster haemopoietic recovery, fewer transfusions and antibiotic usage, and a shorter hospital stay. Furthermore, ease and convenience of PBSC collection made them more appealing than BM harvests. Improved survival has hitherto been demonstrated in patients with high risk AML and CML. However, the advantages of PBSC come at a price of a higher incidence of extensive chronic GVHD. In order to be present in the blood, stem cells undergo the process of "mobilisation" from their bone marrow habitat. Mobilisation, and its reciprocal process - homing - are regulated by a complex network of molecules on the surface of stem cells and stromal cells, and enzymes and cytokines released from granulocytes and osteoclasts. Knowledge of these mechanisms is beginning to be exploited for clinical purposes. In current practice, stem cell are mobilised by use of chemotherapy in conjunction with haemopoietic growth factors (HGF, or with HGF alone. Granulocyte colony stimulating factor has emerged as the single most important mobilising agent, due to its efficacy and a relative paucity of serious side effects. Over a decade of use in healthy donors has resulted in vast experience of optimal dosing and administration, and safety matters. PBSC harvesting can be performed on a variety of cell separators. Apheresis procedures are nowadays routine, but it is important to be well versed in the possible complications in order to avoid harm to the patient or donor. To ensure efficient collection, harvesting must begin when sufficient stem cells have been mobilised. A rapid, reliable, standardized blood test is essential to decide when to begin harvesting; currently, blood CD34+ cell counting by flow cytometry fulfils these criteria. Blood CD34+ cell counts strongly

  8. Laboratory Exercise: Study of Digestive and Regulatory Processes through the Exploration of Fasted and Postprandial Blood Glucose

    Science.gov (United States)

    Hopper, Mari K.; Maurer, Luke W.

    2013-01-01

    Digestive physiology laboratory exercises often explore the regulation of enzyme action rather than systems physiology. This laboratory exercise provides a systems approach to digestive and regulatory processes through the exploration of postprandial blood glucose levels. In the present exercise, students enrolled in an undergraduate animal…

  9. Miniaturized Blood Pressure Telemetry System with RFID Interface

    Directory of Open Access Journals (Sweden)

    Michele Caldara

    2016-08-01

    Full Text Available This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID tag, International Organization for Standardization (ISO 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure wave undergoes embedded processing and results are stored onboard in a non-volatile memory, providing the data under interrogation by an external RFID reader. In order to extend battery lifetime, RFID energy harvesting has been investigated. The paper presents the experimental characterization in a laboratory and preliminary in-vivo tests. The device is a prototype mainly intended, in a future engineered version, for monitoring freely moving test animals for pharmaceutical research and drug safety assessment purposes, but it could have multiple uses in environmental and industrial applications.

  10. Particle Swarm Optimization Algorithm for Optimizing Assignment of Blood in Blood Banking System

    Science.gov (United States)

    Olusanya, Micheal O.; Arasomwan, Martins A.; Adewumi, Aderemi O.

    2015-01-01

    This paper reports the performance of particle swarm optimization (PSO) for the assignment of blood to meet patients' blood transfusion requests for blood transfusion. While the drive for blood donation lingers, there is need for effective and efficient management of available blood in blood banking systems. Moreover, inherent danger of transfusing wrong blood types to patients, unnecessary importation of blood units from external sources, and wastage of blood products due to nonusage necessitate the development of mathematical models and techniques for effective handling of blood distribution among available blood types in order to minimize wastages and importation from external sources. This gives rise to the blood assignment problem (BAP) introduced recently in literature. We propose a queue and multiple knapsack models with PSO-based solution to address this challenge. Simulation is based on sets of randomly generated data that mimic real-world population distribution of blood types. Results obtained show the efficiency of the proposed algorithm for BAP with no blood units wasted and very low importation, where necessary, from outside the blood bank. The result therefore can serve as a benchmark and basis for decision support tools for real-life deployment. PMID:25815046

  11. Particle swarm optimization algorithm for optimizing assignment of blood in blood banking system.

    Science.gov (United States)

    Olusanya, Micheal O; Arasomwan, Martins A; Adewumi, Aderemi O

    2015-01-01

    This paper reports the performance of particle swarm optimization (PSO) for the assignment of blood to meet patients' blood transfusion requests for blood transfusion. While the drive for blood donation lingers, there is need for effective and efficient management of available blood in blood banking systems. Moreover, inherent danger of transfusing wrong blood types to patients, unnecessary importation of blood units from external sources, and wastage of blood products due to nonusage necessitate the development of mathematical models and techniques for effective handling of blood distribution among available blood types in order to minimize wastages and importation from external sources. This gives rise to the blood assignment problem (BAP) introduced recently in literature. We propose a queue and multiple knapsack models with PSO-based solution to address this challenge. Simulation is based on sets of randomly generated data that mimic real-world population distribution of blood types. Results obtained show the efficiency of the proposed algorithm for BAP with no blood units wasted and very low importation, where necessary, from outside the blood bank. The result therefore can serve as a benchmark and basis for decision support tools for real-life deployment.

  12. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    Science.gov (United States)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood

  13. Development of blood extraction system for health monitoring system

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2004-03-01

    The purpose of this research is to develop the compact human blood sampling device applied for a health monitoring system(HMS), which is called "Mobile Hospital". The HMS consists of (1) a micro electrical pumping system for blood extraction, (2) a bio-sensor to detect and evaluate an amount of Glucose, Cholesterol and Urea in extracted blood, by using enzyme such as Glucoseoxidase (GOD), Cholesteroloxidase and Urease. The mechanical design elements of the device are bio-compatible microneedle, indentation unit using a shape memory alloy(SMA) actuator and pumping unit using a piezoelectric microactuator. The design concept is the biomimetic micromachine of female mosquito"s blood sampling mechanism. The performances of the main mechanical elements such as indentation force of the microneedle, actual stroke of the indentation unit using a SMA actuator and liquid sampling ability of the pumping unit using PZT piezoelectric microactuator were measured. The 3 mm stroke of the indentation load generated by SMA actuator was 0.8mN. The amount of imitation blood extracted by using bimorph PZT actuators was about 0.5 microliters for 10 sec. A 60-micrometer outer diameter and 25-micrometer inner diameter Titanium microneedle, which size is same as female mosquito"s labium, was produced by sputter deposition.

  14. Portable blood extraction device integrated with biomedical monitoring system

    Science.gov (United States)

    Khumpuang, S.; Horade, M.; Fujioka, K.; Sugiyama, S.

    2006-01-01

    Painless and portable blood extraction device has been immersed in the world of miniaturization on bio-medical research particularly in manufacturing point-of-care systems. The fabrication of a blood extraction device integrated with an electrolyte-monitoring system is reported in this paper. The device has advantages in precise controlled dosage of blood extracted including the slightly damaged blood vessels and nervous system. The in-house blood diagnostic will become simple for the patients. Main components of the portable system are; the blood extraction device and electrolyte-monitoring system. The monitoring system consists of ISFET (Ion Selective Field Effect Transistor) for measuring the concentration level of minerals in blood. In this work, we measured the level of 3 ions; Na+, K+ and Cl-. The mentioned ions are frequently required the measurement since their concentration levels in the blood can indicate whether the kidney, pancreas, liver or heart is being malfunction. The fabrication of the whole system and experimentation on each ISM (Ion Sensitive Membrane) will be provided. Taking the advantages of LIGA technology, the 100 hollow microneedles fabricated by Synchrotron Radiation deep X-ray lithography through PCT (Plane-pattern to Cross-section Transfer) technique have been consisted in 5x5 mm2 area. The microneedle is 300 μm in base-diameter, 500 μm-pitch, 800 μm-height and 50 μm hole-diameter. The total size of the blood extraction device is 2x2x2 cm 3. The package is made from a plastic socket including slots for inserting microneedle array and ISFET connecting to an electrical circuit for the monitoring. Through the dimensional design for simply handling and selection of disposable material, the patients can self-evaluate the critical level of the body minerals in anywhere and anytime.

  15. How do I provide leukapheresis products? Blood center experience and evidence for process improvement.

    Science.gov (United States)

    Ginzburg, Yelena; Kessler, Debra; Narici, Manlio; Caltabiano, Melinda; Rebosa, Mark; Strauss, Donna; Shaz, Beth

    2013-10-01

    The past few decades have seen a resurgence of interest in leukapheresis products to improve the survival of infected patients with neutropenia. These products have a short shelf life and require donor stimulation with dexamethasone before collection. Additionally, a system with good communications and logistical support is essential. A recent survey of blood centers in North America revealed that the majority of centers collecting leukapheresis products use steroid-stimulated donors. The survey results suggested that an analysis of the process and potential process improvement would be of interest to the transfusion medicine community. Data from 2008 to 2011 regarding donor selection, donor dexamethasone stimulation, leukapheresis collection, and correlations between potentially pertinent variables for process improvement were analyzed. Results from an analysis of cost are also included. We evaluate 432 leukapheresis donations and demonstrate correlations between 1) pre- and poststimulation white blood cell (WBC) count (pproduct granulocyte yield (pimprovement in granulocyte quality and yield can be accomplished in dexamethasone-stimulated donors, by selecting eligible donors with relatively high normal prestimulation WBC counts and/or previously good responses to dexamethasone, increasing the duration between dexamethasone stimulation and granulocyte collection, and maintaining optimal hematocrit (5%-10%) in granulocyte collections. Because the majority of surveyed blood centers collecting stimulated granulocytes use steroids alone, modifications presented here may prove useful. Further assessment of correlation between granulocyte yield and clinical outcome will await results of additional studies. © 2012 American Association of Blood Banks.

  16. Do autologous blood transfusion systems reduce allogeneic blood transfusion in total knee arthroplasty?

    Science.gov (United States)

    Pawaskar, Aditya; Salunke, Abhijeet Ashok; Kekatpure, Aashay; Chen, Yongsheng; Nambi, G I; Tan, Junhao; Sonawane, Dhiraj; Pathak, Subodhkumar

    2017-09-01

    To study whether autologus blood transfusion systems reduce the requirement of allogneic blood transfusion in patients undergoing total knee arthroplasty. A comprehensive search of the published literature with PubMed, Scopus and Science direct database was performed. The following search terms were used: (total knee replacement) OR (total knee arthroplasty) OR (TKA) AND (blood transfusion) OR (autologous transfusion) OR (autologous transfusion system). Using search syntax, a total of 748 search results were obtained (79 from PubMed, 586 from Science direct and 83 from Scopus). Twenty-one randomized control trials were included for this meta-analysis. The allogenic transfusion rate in autologus blood transfusion (study) group was significantly lower than the control group (28.4 and 53.5 %, respectively) (p value 0.0001, Relative risk: 0.5). The median units of allogenic blood transfused in study control group and control group were 0.1 (0.1-3.0) and 1.3 (0.3-2.6), respectively. The median hospital stay in study group was 9 (6.7-15.6) days and control group was 8.7 (6.6-16.7) days. The median cost incurred for blood transfusion per patient in study and control groups was 175 (85.7-260) and 254.7 (235-300) euros, respectively. This meta-analysis demonstrates that the use of auto-transfusion systems is a cost-effective method to reduce the need for and quantity of allogenic transfusion in elective total knee arthroplasty. Level I.

  17. A Blood Bank Information Management System

    Science.gov (United States)

    Farmer, James J.

    1982-01-01

    A computerized Blood Bank Management system is described. Features include product oriented data input, inventory control reports, product utilization reports, rapid retrieval of individual patient reports. Relative benefits of the system are discussed.

  18. Computed aided system for separation and classification of the abnormal erythrocytes in human blood

    Science.gov (United States)

    Wąsowicz, Michał; Grochowski, Michał; Kulka, Marek; Mikołajczyk, Agnieszka; Ficek, Mateusz; Karpieńko, Katarzyna; Cićkiewicz, Maciej

    2017-12-01

    The human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified diamonds and oxidation modified. The blood was put under an impact of two diamond concentrations: 20μl and 100μl. The amount of abnormal cells increased with time. The percentage of echinocytes as a result of interaction with nanodiamonds in various time intervals for individual specimens was scarce. The impact of the two diamond types had no clinical importance on red blood cells. It is supposed that as a result of longlasting exposure a dehydratation of red cells takes place, because of the function of the cells. The analysis of an influence of nanodiamond particles on blood elements was supported by computer system designed for automatic counting and classification of the Red Blood Cells (RBC). The system utilizes advanced image processing methods for RBCs separation and counting and Eigenfaces method coupled with the neural networks for RBCs classification into normal and abnormal cells purposes.

  19. Optics based signal processing methods for intraoperative blood vessel detection and quantification in real time (Conference Presentation)

    Science.gov (United States)

    Chaturvedi, Amal; Shukair, Shetha A.; Le Rolland, Paul; Vijayvergia, Mayank; Subramanian, Hariharan; Gunn, Jonathan W.

    2016-03-01

    Minimally invasive operations require surgeons to make difficult cuts to blood vessels and other tissues with impaired tactile and visual feedback. This leads to inadvertent cuts to blood vessels hidden beneath tissue, causing serious health risks to patients and a non-reimbursable financial burden to hospitals. Intraoperative imaging technologies have been developed, but these expensive systems can be cumbersome and provide only a high-level view of blood vessel networks. In this research, we propose a lean reflectance-based system, comprised of a dual wavelength LED, photodiode, and novel signal processing algorithms for rapid vessel characterization. Since this system takes advantage of the inherent pulsatile light absorption characteristics of blood vessels, no contrast agent is required for its ability to detect the presence of a blood vessel buried deep inside any tissue type (up to a cm) in real time. Once a vessel is detected, the system is able to estimate the distance of the vessel from the probe and the diameter size of the vessel (with a resolution of ~2mm), as well as delineate the type of tissue surrounding the vessel. The system is low-cost, functions in real-time, and could be mounted on already existing surgical tools, such as Kittner dissectors or laparoscopic suction irrigation cannulae. Having been successfully validated ex vivo, this technology will next be tested in a live porcine study and eventually in clinical trials.

  20. Quality indicators for discarding blood in the National Blood Center, Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Mohammed Morish

    2012-01-01

    Full Text Available Background and Objective: The implementation of quality system and continuous evaluation of all activities of the Blood Transfusion Services (BTS can help to achieve the maximum quantity and quality of safe blood. Optimizing blood collection and processing would reduce the rate of discard and improve the efficiency of the BTS. The objective of this study is to determine the rate of discard of blood and blood component and identify its reasons at the National Blood Centre (NBC, Kuala Lumpur, during the year of 2007 in order to introduce appropriate intervention. Study Designs and Methods: Data on the number of discarded whole blood units and its components, reasons for discard, and the number of blood components processed as well as the number of collected blood units were obtained from the Blood Bank Information System - NBC database. These were analyzed. Results: The total number of blood units collected in 2007 was 171169 from which 390636 units of components were prepared. The total number of discarded whole blood units and its components was 8968 (2.3%. Platelet concentrate recorded the highest of discard at 6% (3909 followed by whole blood at 3.7% (647, fresh frozen plasma (FFP at 2.5% (2839, and cryoprecipitate at 2% (620. The rate of discarded packed red blood cells RBCs, plasma aphaeresis, and PLT aphaeresis was less than 1% at 0.6% (902, 0.6% (37, and 0.29% (14, respectively. RBC contamination of PLT and plasma were the major cause of discard at 40% (3558. Other causes include leakage (26% - 2306, lipemia (25% - 2208, and underweight (4% - 353. Conclusion: Good donor selection, training and evaluation of the staff, as well as implementation of automation will help to improve processes and output of BTS. This would reduce discard of blood components and wastage caused by non conformance.

  1. Dynamic expression of leukocyte innate immune genes in whole blood from horses with lipopolysaccharide-induced acute systemic inflammation

    DEFF Research Database (Denmark)

    Vinther, Anne Mette L.; Skovgaard, Kerstin; Heegaard, Peter M. H.

    2015-01-01

    Background: In horses, insights into the innate immune processes in acute systemic inflammation are limited even though these processes may be highly important for future diagnostic and therapeutic advances in high-mortality disease conditions as the systemic inflammatory response syndrome (SIRS......) and sepsis. Therefore, the aim of this study was to investigate the expression of 31 selected blood leukocyte immune genes in an equine model of acute systemic inflammation to identify significantly regulated genes and to describe their expression dynamics during a 24-h experimental period. Systemic...... expressions in blood leukocytes during equine acute LPS-induced systemic inflammation thoroughly characterized a highly regulated and dynamic innate immune response. These results provide new insights into the molecular mechanisms of equine systemic inflammation....

  2. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  3. Optimizing preoperative blood ordering with data acquired from an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Rothschild, James A; Masear, Courtney G; Rivers, Richard J; Merritt, William T; Savage, Will J; Ness, Paul M

    2013-06-01

    The maximum surgical blood order schedule (MSBOS) is used to determine preoperative blood orders for specific surgical procedures. Because the list was developed in the late 1970s, many new surgical procedures have been introduced and others improved upon, making the original MSBOS obsolete. The authors describe methods to create an updated, institution-specific MSBOS to guide preoperative blood ordering. Blood utilization data for 53,526 patients undergoing 1,632 different surgical procedures were gathered from an anesthesia information management system. A novel algorithm based on previously defined criteria was used to create an MSBOS for each surgical specialty. The economic implications were calculated based on the number of blood orders placed, but not indicated, according to the MSBOS. Among 27,825 surgical cases that did not require preoperative blood orders as determined by the MSBOS, 9,099 (32.7%) had a type and screen, and 2,643 (9.5%) had a crossmatch ordered. Of 4,644 cases determined to require only a type and screen, 1,509 (32.5%) had a type and crossmatch ordered. By using the MSBOS to eliminate unnecessary blood orders, the authors calculated a potential reduction in hospital charges and actual costs of $211,448 and $43,135 per year, respectively, or $8.89 and $1.81 per surgical patient, respectively. An institution-specific MSBOS can be created, using blood utilization data extracted from an anesthesia information management system along with our proposed algorithm. Using these methods to optimize the process of preoperative blood ordering can potentially improve operating room efficiency, increase patient safety, and decrease costs.

  4. DNA Damages and White Blood Cell Death Processes in Victims with Severe Injury

    Directory of Open Access Journals (Sweden)

    V. V. Moroz

    2014-01-01

     pase3, caspase9, superoxide dismutase, and sAPO1/FAS were measured by enzyme immunoassay using test systems(Bender MedSystems, Austria.Results. There were significantly higher plasma levels of free DNA in the victims than in the controls throughout the followup, which is due to its exit from the cells damaged from tissue injury. In the first two weeks after injury, there were increases in DNA damages and white blood cell alteration processes by a necrotic and apoptotic mechanism in the victims with different types of injury, which may be associated with the active participation of leuko cytes in the processes of cellular breakdown product removal in the tissues damaged during injury and the in those of prevention of infectious complications. In the victims, white blood cell alteration in the necrotic pathway does not depend on BLV and hypoxia degree while that in the apoptotic pathway showed a relationship of leukocyte alteration to hypoxia in these patients. The sum of the values of necrotic DNA comets, apoptotic DNA comets, and single and doublestrand breaks on day 3 postinjury may serve as a predictor of the likely development of infectious complications in victims with injury, blood loss, and marked hypoxia. There were differences in the levels of DNA damages and white blood cell apoptosis and necrosis in the victims with BI and SSI. The injury victims showed a threefold decrease in plasma 8hydroxy2 deoxyguanosine concentrations, which was accompanied and, possibly, caused by an increase in the amount of superoxide dismutase.Conclusion. There was a relationship between the degree of DNA damages, apoptosis, and necrosis in the white blood cells of victims with injury and hypoxiainduced blood loss.

  5. Analysis of inventory strategies for blood components in a regional blood center using process simulation.

    Science.gov (United States)

    Baesler, Felipe; Nemeth, Matías; Martínez, Cristina; Bastías, Alfonso

    2014-02-01

    The storage of blood components is an important concern in the blood supply chain. Because these are perishable products, the definition of good inventory policies is crucial to reduce shortages and spills. To analyze and propose inventory policies in a regional blood center, a discrete event simulation model was created using simulation software (Arena 12.0, Rockwell Software). The model replicates the activities that are performed along the supply chain including donation arrivals, testing, production, inventory management, and dispatching. Twelve different scenarios were analyzed, with each one representing different inventory policies composed of a combination of an optimal inventory, a reorder point, and a level of extra donations. The best scenario demonstrates that it is possible to decrease unsatisfied demand and wastage of red blood cell units by 2.5 and 3%, respectively, when compared to current practices. This study shows that simulation is an alternative that can be used to model inventory components in blood centers. A responsible selection of inventory variables can improve the capability of the system to respond to the final patient requirements. © 2013 American Association of Blood Banks.

  6. Use of statistical process control in the production of blood components

    DEFF Research Database (Denmark)

    Magnussen, K.; Quere, S.; Winkel, P.

    2008-01-01

    occasional component manufacturing staff to an experienced regular manufacturing staff. Production of blood products is a semi-automated process in which the manual steps may be difficult to control. This study was performed in an ongoing effort to improve the control and optimize the quality of the blood...

  7. Collision Based Blood Cell Distribution of the Blood Flow

    Science.gov (United States)

    Cinar, Yildirim

    2003-11-01

    Introduction: The goal of the study is the determination of the energy transferring process between colliding masses and the application of the results to the distribution of the cell, velocity and kinetic energy in arterial blood flow. Methods: Mathematical methods and models were used to explain the collision between two moving systems, and the distribution of linear momentum, rectilinear velocity, and kinetic energy in a collision. Results: According to decrease of mass of the second system, the velocity and momentum of constant mass of the first system are decreased, and linearly decreasing mass of the second system captures a larger amount of the kinetic energy and the rectilinear velocity of the collision system on a logarithmic scale. Discussion: The cause of concentration of blood cells at the center of blood flow an artery is not explained by Bernoulli principle alone but the kinetic energy and velocity distribution due to collision between the big mass of the arterial wall and the small mass of blood cells must be considered as well.

  8. The donor line break cannula: effect on the donation process, blood component quality and transfusion microbiology testing of an important new blood bag safety feature.

    Science.gov (United States)

    Nightingale, M J; Beard, M J; Bennett, J; Hambleton, R; Ramskill, S; Thomas, S

    2013-08-01

    The use of blood packs with an integral sampling system can result in anti-coagulant from the main bag reaching the sample pouch via the donor line, causing delayed coagulation of blood samples. In NHS Blood and Transplant, this has prevented the use of serum, the preferred matrix for transfusion microbiology (TM) testing, which has led to an increased false positive rate with ethylenediaminetetraacetic acid (EDTA) plasma. There is also a remote possibility of false negative results owing to sample dilution. Manufacturers have responded by offering packs with a donor line break cannula (DLBC) to prevent these adverse effects. The aims of this study were to assess the impact of DLBC packs on donation, blood component quality and of the potential return to serum for TM testing. DLBC packs from three manufacturers were assessed against control packs of the same dimensions and configuration. Donation duration, flow rate, platelet factor 4, prothrombin fragment 1+2, haemolysis and collection and processing incidents were compared. Results indicated no clinically significant adverse effect from the DLBC on the activation state of platelets, the coagulation cascade or increased haemolysis. Donation duration and blood collection and processing incident rates for DLBC packs were not significantly different to controls. The use of DLBC packs would reduce the complexity of manipulations during blood collection and therefore the likelihood of microbially contaminated donations (incorrect skin core diversion) and false negative TM tests. DLBC packs would enable the use of serum for TM testing with a significant reduction in false positive tests compared to EDTA plasma. © 2013 The Authors. Transfusion Medicine © 2013 British Blood Transfusion Society.

  9. Hospital billing for blood processing and transfusion for inpatient stays.

    Science.gov (United States)

    McCue, Michael J; Nayar, Preethy

    2009-07-01

    Medicare, an important payer for hospitals, reimburses hospitals for inpatient stays using Diagnosis Related Groups (DRGs). Many private insurers also use the DRG methodology to reimburse hospitals for their services. Therefore, those blood service organizations that bill Medicare directly require an understanding of the DRG system of payment to enable them to bill Medicare correctly, and in order to be certain they are adequately reimbursed. Blood centers that do not bill Medicare directly need to understand how hospitals are reimbursed for blood and blood components as this affects a hospital's ability to pay service fees related to these products. This review presents a detailed explanation of how hospitals are reimbursed by the Centers for Medicare and Medicaid Services (CMS) for Medicare inpatient services, including blood services.

  10. Blood Sample Transportation by Pneumatic Transportation Systems

    DEFF Research Database (Denmark)

    Nybo, Mads; Lund, Merete E; Titlestad, Kjell

    2018-01-01

    BACKGROUND: Pneumatic transportation systems (PTSs) are increasingly used for transportation of blood samples to the core laboratory. Many studies have investigated the impact of these systems on different types of analyses, but to elucidate whether PTSs in general are safe for transportation...... analysis, and the hemolysis index). CONCLUSIONS: Owing to their high degree of heterogeneity, the retrieved studies were unable to supply evidence for the safety of using PTSs for blood sample transportation. In consequence, laboratories need to measure and document the actual acceleration forces...

  11. Can a decentralized blood system ensure self-sufficiency and blood safety? The Lebanese experience.

    Science.gov (United States)

    Haddad, Antoine; Bou Assi, Tarek; Garraud, Olivier

    2017-08-01

    Lebanon has adopted a liberal economic system that also applies to healthcare procurement. There is no national Lebanese blood transfusion service and the blood supply is divided between a large number of licensed (45 per cent) and unlicensed (55 per cent) blood banks, many of them issuing a very limited number of blood components. All blood banks are hospital based and operate the entire transfusion chain, from collection to the release of blood units. Blood donation is voluntary and non-remunerated in 20-25 per cent of donations; it relies principally on replacement donations. Recently, Lebanon has faced political instability and war, and now welcomes an enormous number of refugees from neighboring countries at war. This has had an important impact on heath care and on the transfusion supply. We discuss the impact of the blood donation organization on the transfusion safety and ethics, to set the foundation for a more developed and safer transfusion programs.

  12. 21 CFR 864.9175 - Automated blood grouping and antibody test system.

    Science.gov (United States)

    2010-04-01

    ...) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red blood cells) and to detect antibodies to blood group antigens. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system...

  13. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.

    Science.gov (United States)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana; Bech, Bodil Hammer; Fuglsang, Jens; Olsen, Jørn; Nohr, Ellen Aagaard

    2015-01-01

    In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing. Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification. For samples taken in the winter, relative differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate there was no difference between the two setups [corresponding estimate 1% (0, 3)]. Differences were negligible in the summer for all compounds. Transport of blood samples and processing delay, similar to conditions applied in some large, population-based studies, may affect measured perfluoroalkyl acid concentrations, mainly when outdoor temperatures are low. Attention to processing conditions is needed in studies of perfluoroalkyl acid exposure in humans.

  14. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  15. Blood Donation Process

    Science.gov (United States)

    ... this site from a secured browser on the server. Please enable scripts and reload this page. Find ... Correspondence Regulatory and Public Meetings Stop the Bleed Professional Development Education Annual Meeting International Cord Blood Symposium ...

  16. Pretreatment of whole blood using hydrogen peroxide and UV irradiation. Design of the advanced oxidation process.

    Science.gov (United States)

    Bragg, Stefanie A; Armstrong, Kristie C; Xue, Zi-Ling

    2012-08-15

    A new process to pretreat blood samples has been developed. This process combines the Advanced Oxidation Process (AOP) treatment (using H(2)O(2) and UV irradiation) with acid deactivation of the enzyme catalase in blood. A four-cell reactor has been designed and built in house. The effect of pH on the AOP process has been investigated. The kinetics of the pretreatment process shows that at high C(H(2)O(2),t=0), the reaction is zeroth order with respect to C(H(2)O(2)) and first order with respect to C(blood). The rate limiting process is photon flux from the UV lamp. Degradation of whole blood has been compared with that of pure hemoglobin samples. The AOP pretreatment of the blood samples has led to the subsequent determination of chromium and zinc concentrations in the samples using electrochemical methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Discovering objects in a blood recipient information system.

    Science.gov (United States)

    Qiu, D; Junghans, G; Marquardt, K; Kroll, H; Mueller-Eckhardt, C; Dudeck, J

    1995-01-01

    Application of object-oriented (OO) methodologies has been generally considered as a solution to the problem of improving the software development process and managing the so-called software crisis. Among them, object-oriented analysis (OOA) is the most essential and is a vital prerequisite for the successful use of other OO methodologies. Though there are already a good deal of OOA methods published, the most important aspect common to all these methods: discovering objects classes truly relevant to the given problem domain, has remained a subject to be intensively researched. In this paper, using the successful development of a blood recipient information system as an example, we present our approach which is based on the conceptual framework of responsibility-driven OOA. In the discussion, we also suggest that it may be inadequate to simply attribute the software crisis to the waterfall model of the software development life-cycle. We are convinced that the real causes for the failure of some software and information systems should be sought in the methodologies used in some crucial phases of the software development process. Furthermore, a software system can also fail if object classes essential to the problem domain are not discovered, implemented and visualized, so that the real-world situation cannot be faithfully traced by it.

  18. Electronic remote blood issue: a combination of remote blood issue with a system for end-to-end electronic control of transfusion to provide a "total solution" for a safe and timely hospital blood transfusion service.

    Science.gov (United States)

    Staves, Julie; Davies, Amanda; Kay, Jonathan; Pearson, Oliver; Johnson, Tony; Murphy, Michael F

    2008-03-01

    The rapid provision of red cell (RBC) units to patients needing blood urgently is an issue of major importance in transfusion medicine. The development of electronic issue (sometimes termed "electronic crossmatch") has facilitated rapid provision of RBC units by avoidance of the serologic crossmatch in eligible patients. A further development is the issue of blood under electronic control at blood refrigerator remote from the blood bank. This study evaluated a system for electronic remote blood issue (ERBI) developed as an enhancement of a system for end-to-end electronic control of hospital transfusion. Practice was evaluated before and after its introduction in cardiac surgery. Before the implementation of ERBI, the median time to deliver urgently required RBC units to the patient was 24 minutes. After its implementation, RBC units were obtained from the nearby blood refrigerator in a median time of 59 seconds (range, 30 sec to 2 min). The study also found that unused requests were reduced significantly from 42 to 20 percent, the number of RBC units issued reduced by 52 percent, the number of issued units that were transfused increased from 40 to 62 percent, and there was a significant reduction in the workload of both blood bank and clinical staff. This study evaluated a combination of remote blood issue with an end-to-end electronically controlled hospital transfusion process, ERBI. ERBI reduced the time to make blood available for surgical patients and improved the efficiency of hospital transfusion.

  19. Survival of red blood cells after transfusion: processes and consequences

    Directory of Open Access Journals (Sweden)

    Giel eBosman

    2013-12-01

    Full Text Available The currently available data suggest that efforts towards improving the quality of red blood cell (RBC blood bank products should concentrate on: (1 preventing the removal of a considerable fraction of the transfused RBCs that takes place within the first hours after transfusion; (2 minimizing the interaction of the transfused RBCs with the patient's immune system. These issues are important in reducing the number and extent of the damaging side effects of transfusions, such as generation of alloantibodies and autoantibodies and iron accumulation, especially in transfusion-dependent patients. Thus, it becomes important for blood bank research not only to assess the classical RBC parameters for quality control during storage, but even more so to identify the parameters that predict RBC survival, function and behaviour in the patient after transfusion. These parameters are likely to result from elucidation of the mechanisms that underly physiological RBC aging in vivo, and that lead to the generation of senescent cell antigens and the accumulation of damaged molecules in vesicles. Also, study of RBC pathology-related mechanisms, such as encountered in various hemoglobinopathies and membranopathies, may help to elucidate the mechanisms underlying a storage-associated increase in susceptibility to physiological stress conditions. Recent data indicate that a combination of new approaches in vitro to mimick RBC behaviour in vivo, the growing knowledge of the signaling networks that regulate RBC structure and function, and the rapidly expanding set of proteomic and metabolomic data, will be instrumental to identify the storage-associated processes that control RBC survival after transfusion.

  20. Development of blood extraction system designed by female mosquito's blood sampling mechanism for bio-MEMS

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2005-02-01

    A compact and wearable wristwatch type Bio-MEMS such as a health monitoring system (HMS) to detect blood sugar level for diabetic patient, was newly developed. The HMS consists of (1) a indentation unit with a microneedle to generate the skin penetration force using a shape memory alloy(SMA) actuator, (2) a pumping unit using a bimorph PZT piezoelectric actuator to extract the blood and (3) a gold (Au) electrode as a biosensor immobilized GOx and attached to the gate electrode of MOSFET to detect the amount of Glucose in extracted blood. GOx was immobilized on a self assembled spacer combined with an Au electrode by the cross-link method using BSA as an additional bonding material. The device can extract blood in a few microliter through a painless microneedle with the negative pressure by deflection of the bimorph PZT piezoelectric actuator produced in the blood chamber, by the similar way the female mosquito extracts human blood with muscle motion to flex or relax. The performances of the liquid sampling ability of the pumping unit through a microneedle (3.8mm length, 100μm internal diameter) using the bimorph PZT piezoelectric microactuator were measured. The blood extraction micro device could extract human blood at the speed of 2μl/min, and it is enough volume to measure a glucose level, compared to the amount of commercial based glucose level monitor. The electrode embedded in the blood extraction device chamber could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose in a few microliter extracted blood, using the constant electric current measurement system of the MOSFET type hybrid biosensor. The output voltage for the glucose diluted in the chamber was increased lineally with increase of the glucose concentration.

  1. Performance of Gram staining on blood cultures flagged negative by an automated blood culture system.

    Science.gov (United States)

    Peretz, A; Isakovich, N; Pastukh, N; Koifman, A; Glyatman, T; Brodsky, D

    2015-08-01

    Blood is one of the most important specimens sent to a microbiology laboratory for culture. Most blood cultures are incubated for 5-7 days, except in cases where there is a suspicion of infection caused by microorganisms that proliferate slowly, or infections expressed by a small number of bacteria in the bloodstream. Therefore, at the end of incubation, misidentification of positive cultures and false-negative results are a real possibility. The aim of this work was to perform a confirmation by Gram staining of the lack of any microorganisms in blood cultures that were identified as negative by the BACTEC™ FX system at the end of incubation. All bottles defined as negative by the BACTEC FX system were Gram-stained using an automatic device and inoculated on solid growth media. In our work, 15 cultures that were defined as negative by the BACTEC FX system at the end of the incubation were found to contain microorganisms when Gram-stained. The main characteristic of most bacteria and fungi growing in the culture bottles that were defined as negative was slow growth. This finding raises a problematic issue concerning the need to perform Gram staining of all blood cultures, which could overload the routine laboratory work, especially laboratories serving large medical centers and receiving a large number of blood cultures.

  2. Relationship between systemic hemodynamics and ambulatory blood pressure level are sex dependent.

    Science.gov (United States)

    Alfie, J; Waisman, G D; Galarza, C R; Magi, M I; Vasvari, F; Mayorga, L M; Cámera, M I

    1995-12-01

    Sex-related differences in systemic hemodynamics were analyzed by means of cardiac index and systemic vascular resistance according to the level of daytime ambulatory blood pressure. In addition, we assessed the relations between ambulatory blood pressure measurements and systemic hemodynamics in male and female patients. We prospectively included 52 women and 53 men referred to our unit for evaluation of arterial hypertension. Women and men were grouped according to the level of daytime mean arterial pressure: or = 110 mm Hg. Patients underwent noninvasive evaluation of resting hemodynamics (impedance cardiography) and 24-hour ambulatory blood pressure monitoring. Compared with women men with lower daytime blood pressure had a 12% higher systemic vascular resistance index (P = NS) and a 14% lower cardiac index (P < .02), whereas men with higher daytime blood pressure had a 25% higher vascular resistance (P < .003) and a 21% lower cardiac index (P < .0004). Furthermore, in men systemic vascular resistance correlated positively with both daytime and nighttime systolic and diastolic blood pressures, whereas cardiac index correlated negatively only with daytime diastolic blood pressure. In contrast, women did not exhibit any significant correlation between hemodynamic parameters and ambulatory blood pressure measurements. In conclusion, sex-related differences in systemic hemodynamics were more pronounced in the group with higher daytime hypertension. The relations between systemic hemodynamics and ambulatory blood pressure level depended on the sex of the patient. In men a progressive circulatory impairment underlies the increasing level of ambulatory blood pressure, but this was not observed in women.

  3. The rheologic properties of red blood cells processed by 2 different types of cell savers, and its effects on microcirculatory blood flow and tissue oxygenation in vivo.

    NARCIS (Netherlands)

    Scheeren, Thomas; de Lange, S.; Martinez, A.; Hagenaars, Johanna A. M.; Ben Ayad, N.; de Vries, Hans

    2016-01-01

    Introduction: Cell savers (CS) reduce the percentage of patients who need blood products during cardiac surgery. While some CS use discontinuous blood processing with a spinning bowl, others use continuous blood processing based on the elutriation principle. Both may influence aggregation and

  4. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  5. Blood component fractionation: manual versus automatic procedures.

    Science.gov (United States)

    Pasqualetti, Daniela; Ghirardini, Alessandro; Cristina Arista, Maria; Vaglio, Stefania; Fakeri, Azis; Waldman, Alan A; Girelli, Gabriella

    2004-02-01

    Over the last few years, quality system requirements have been introduced for blood components. The necessary compliance with standard productions will have a considerable impact on Blood Banks. The introduction of automated methods is the most satisfactory means to meet these requirements for blood component preparation. A new device has been developed to automate the fractionation of blood into components. We evaluated the efficacy of this instrument as compared to manual methods. A total of 218 units of blood have been collected, into several different commercial blood bag systems (77 into standard quadruple bag systems, 141 into bag systems with integrated in line filters), and used to evaluate the universality of the instrument. Whole blood units were processed using the Top/Top system and the Compomat G4 (Fresenius HemoCare). A separate program protocol was developed for each kind of bag. Use of the Compomat G4 resulted in a statistically significant (pblood components, and has been shown adaptable to use with different blood bag systems.

  6. Clinical comparison of two commercial blood culture systems

    NARCIS (Netherlands)

    Spanjaard, L.; Kuijper, E. J.; Dankert, J.

    2000-01-01

    A prospective, volume-controlled comparison of the BacT/Alert FAN (Organon Teknika, USA) and Vital (bioMérieux, France) blood culture systems was performed in a university hospital during a period of 11 months. Twenty to 40 ml of blood drawn from an adult patient was distributed equally between a

  7. An Automatic Lab-on-Disc System for Blood Typing.

    Science.gov (United States)

    Chang, Yaw-Jen; Fan, Yi-Hua; Chen, Shia-Chung; Lee, Kuan-Hua; Lou, Liao-Yong

    2018-04-01

    A blood-typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This article presents a lab-on-disc blood-typing system to conduct a total of eight assays for a patient, including forward-typing tests, reverse-typing tests, and irregular-antibody tests. These assays are carried out in a microfluidic disc simultaneously. A blood-typing apparatus was designed to automatically manipulate the disc. The blood type can be determined by integrating the results of red blood cell (RBC) agglutination in the microchannels. The experimental results of our current 40 blood samples show that the results agree with those examined in the hospital. The accuracy reaches 97.5%.

  8. Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia

    International Nuclear Information System (INIS)

    Weinstein, M.P.; Mirrett, S.; Reller, L.B.

    1988-01-01

    The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilus species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi

  9. The schistosome oesophageal gland: initiator of blood processing.

    Directory of Open Access Journals (Sweden)

    Xiao-Hong Li

    Full Text Available BACKGROUND: Although the ultrastructure of the schistosome esophageal gland was described >35 years ago, its role in the processing of ingested blood has never been established. The current study was prompted by our identification of MEG-4.1 expression in the gland and the observation of erythrocyte uncoating in the posterior esophagus. METHODOLOGY/PRINCIPAL FINDINGS: The salient feature of the posterior esophagus, characterized by confocal and electron microscopy, is the enormous increase in membrane surface area provided by the plate-like extensions and basal invaginations of the lining syncytium, with unique crystalloid vesicles releasing their contents between the plates. The feeding process was shown by video microscopy to be divided into two phases, blood first accumulating in the anterior lumen before passing as a bolus to the posterior. There it streamed around a plug of material revealed by confocal microscopy as tethered leucocytes. These were present in far larger numbers than predicted from the volume of the lumen, and in varying states of damage and destruction. Intact erythrocytes were detected in the anterior esophagus but not observed thereafter, implying that their lysis occurred rapidly as they enter the posterior. Two further genes, MEGs 4.2 and 14, were shown to be expressed exclusively in the esophageal gland. Bioinformatics predicted that MEGs 4.1 and 4.2 possessed a common hydrophobic region with a shared motif, while antibodies to SjMEG-4.1 showed it was bound to leucocytes in the esophageal lumen. It was also predicted that MEGs 4.1 and 14 were heavily O-glycosylated and this was confirmed for the former by 2D-electrophoresis and Western blotting. CONCLUSIONS/SIGNIFICANCE: The esophageal gland and its products play a central role in the processing of ingested blood. The binding of host antibodies in the esophageal lumen shows that some constituents are antibody targets and could provide a new source of vaccine candidates.

  10. Real-time electrical impedimetric monitoring of blood coagulation process under temperature and hematocrit variations conducted in a microfluidic chip.

    Directory of Open Access Journals (Sweden)

    Kin Fong Lei

    Full Text Available Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity.

  11. Suppression of spleen pathological function by roentgenoendovascular occlussion in some blood systemic diseases

    International Nuclear Information System (INIS)

    Rabkin, I.Kh.; Matevosov, A.L.; Gotman, L.N.

    1987-01-01

    It is shown that REO of splenic artery in thrombocytopenic purpura, hypoplastic and autoimmune hemolytic anemia manifests the same clinical effect as splenectomy. This treatment procedure may substitute splenectomy in a definite group of patients with above-mentioned blood systemic diseases or precede it as a preparation and prognosis stage. Stage-by-stage total embolization of splenic artery is a necessary technical method permitting to attain the necessary medical effect without risk of developing acute spleen infarction. At present REO is used in some blood diseases in patients with high risk of operation, particularly with active hemorrhagic syndrome of adrenal insufficiency, concomitant inflammatory processes

  12. Variability in blood and blood component utilization as assessed by an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Savage, Will J; Rothschild, Jim A; Rivers, Richard J; Ness, Paul M; Paul, Sharon L; Ulatowski, John A

    2012-07-01

    Data can be collected for various purposes with anesthesia information management systems. The authors describe methods for using data acquired from an anesthesia information management system to assess intraoperative utilization of blood and blood components. Over an 18-month period, data were collected on 48,086 surgical patients at a tertiary care academic medical center. All data were acquired with an automated anesthesia recordkeeping system. Detailed reports were generated for blood and blood component utilization according to surgical service and surgical procedure, and for individual surgeons and anesthesiologists. Transfusion hemoglobin trigger and target concentrations were compared among surgical services and procedures, and between individual medical providers. For all patients given erythrocytes, the mean transfusion hemoglobin trigger was 8.4 ± 1.5, and the target was 10.2 ± 1.5 g/dl. Variation was significant among surgical services (trigger range: 7.5 ± 1.2-9.5 ± 1.1, P = 0.0001; target range: 9.1 ± 1.2-11.3 ± 1.4 g/dl, P = 0.002), surgeons (trigger range: 7.2 ± 0.7-9.8 ± 1.0, P = 0.001; target range: 8.8 ± 0.9-11.8 ± 1.3 g/dl, P = 0.001), and anesthesiologists (trigger range: 7.2 ± 0.8-9.6 ± 1.2, P = 0.001; target range: 9.0 ± 0.9-11.7 ± 1.3 g/dl, P = 0.0004). The use of erythrocyte salvage, fresh frozen plasma, and platelets varied threefold to fourfold among individual surgeons compared with their peers performing the same surgical procedure. The use of data acquired from an anesthesia information management system allowed a detailed analysis of blood component utilization, which revealed significant variation among surgical services and surgical procedures, and among individual anesthesiologists and surgeons compared with their peers. Incorporating these methods of data acquisition and analysis into a blood management program could reduce unnecessary transfusions, an outcome that may increase patient safety and reduce costs.

  13. Pulmonary and systemic blood flow contributions to upper airways in canine lung

    International Nuclear Information System (INIS)

    Barman, S.A.; Ardell, J.L.; Parker, J.C.; Perry, M.L.; Taylor, A.E.

    1988-01-01

    The blood flow contributions and drainage patterns of the pulmonary and systemic circulations in the upper airways (trachea and main bronchi) were assessed in anesthetized dogs by injecting 15-μm radiolabeled microspheres into the right and left heart, respectively. After the animals were killed, the tracheal cartilage, tracheal muscle-mucosa, and main bronchi were excised. The tracheal cartilage and tracheal muscle-mucosa were divided into lower, middle, and upper segments for blood flow determinations. The pulmonary contribution to tracheal blood flow was very small, being higher in the lower segments. The systemic contribution to these same tracheal regions was significantly higher, and higher in the upper segments. The pulmonary and systemic circulations each contributed ∼50% to the main bronchi blood flow. The pulmonary blood flow contribution alone to the trachea and main bronchi was also determined in subsequent experiments that utilized the isolated lung, and these blood flows were not significantly different from the pulmonary contribution measured in the intact lungs. The present results indicate that the systemic (bronchial) circulation is the primary source of tracheal blood flow and that both the pulmonary and systemic circulations may contribute ∼50% of the blood flow to the main bronchi in dog lungs

  14. Differences in metabolite profiles caused by pre-analytical blood processing procedures.

    Science.gov (United States)

    Nishiumi, Shin; Suzuki, Makoto; Kobayashi, Takashi; Yoshida, Masaru

    2018-05-01

    Recently, the use of metabolomic analysis of human serum and plasma for biomarker discovery and disease diagnosis in clinical studies has been increasing. The feasibility of using a metabolite biomarker for disease diagnosis is strongly dependent on the metabolite's stability during pre-analytical blood processing procedures, such as serum or plasma sampling and sample storage prior to centrifugation. However, the influence of blood processing procedures on the stability of metabolites has not been fully characterized. In the present study, we compared the levels of metabolites in matched human serum and plasma samples using gas chromatography coupled with mass spectrometry and liquid chromatography coupled with mass spectrometry. In addition, we evaluated the changes in plasma metabolite levels induced by storage at room temperature or at a cold temperature prior to centrifugation. As a result, it was found that 76 metabolites exhibited significant differences between their serum and plasma levels. Furthermore, the pre-centrifugation storage conditions significantly affected the plasma levels of 45 metabolites. These results highlight the importance of blood processing procedures during metabolome analysis, which should be considered during biomarker discovery and the subsequent use of biomarkers for disease diagnosis. Copyright © 2017 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  15. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  16. Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay

    DEFF Research Database (Denmark)

    Bach, Cathrine Carlsen; Henriksen, Tine Brink; Bossi, Rossana

    2015-01-01

    and transportation prior to processing and samples with immediate processing and freezing. METHODS: Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed...... and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification. RESULTS: For samples taken in the winter, relative...... differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate...

  17. Benefits to blood banks of a sales and operations planning process.

    Science.gov (United States)

    Keal, Donald A; Hebert, Phil

    2010-12-01

    A formal sales and operations planning (S&OP) process is a decision making and communication process that balances supply and demand while integrating all business operational components with customer-focused business plans that links high level strategic plans to day-to-day operations. Furthermore, S&OP can assist in managing change across the organization as it provides the opportunity to be proactive in the face of problems and opportunities while establishing a plan for everyone to follow. Some of the key outcomes from a robust S&OP process in blood banking would include: higher customer satisfaction (donors and health care providers), balanced inventory across product lines and customers, more stable production rates and higher productivity, more cooperation across the entire operation, and timely updates to the business plan resulting in better forecasting and fewer surprises that negatively impact the bottom line. © 2010 American Association of Blood Banks.

  18. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    Directory of Open Access Journals (Sweden)

    F. Majlessi

    2008-06-01

    Full Text Available The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sectional study was performed on 554 blood donors who had donated blood from February 2005 through September 2005 in four fixed blood donation bases and four mobile blood collection buses. Each base was considered as a stratum, and a stratified random sampling proportional to size was done to select the donors. Results showed donor reaction rate to be 13.4%, the most common of which were blackout of vision (7%, dizziness (6.3%, fatigue (6.1% and nausea (1.8%. There was no significant relationship between the incidence of these complications and type of base blood donation or fasting at the time of blood donation. Logistic Regression analysis showed that sex, condition of blood donor, exercise or walking, duration of donation, and practice to recommendation had significant effects on the odds ratio of systemic complication. Regarding the frequency values derived for the different systemic complications it can be concluded that attention to risk factors of these complications and their control can help encourage donors to become repeated donors as well as to prevent their withdrawal for further blood donation.

  19. Blood and Blood Components: From Similarities to Differences

    Directory of Open Access Journals (Sweden)

    Olivier Garraud

    2018-04-01

    Full Text Available Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025, many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations of blood transfusion diversity and the consequences for donors, patients, and society.

  20. Blood and Blood Components: From Similarities to Differences

    Science.gov (United States)

    Garraud, Olivier; Tissot, Jean-Daniel

    2018-01-01

    Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation) either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025), many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations) of blood transfusion diversity and the consequences for donors, patients, and society. PMID:29686986

  1. Impact of blood processing variations on Natural Killer cell frequency, activation, chemokine receptor expression and function

    Science.gov (United States)

    Naranbhai, Vivek; Bartman, Pat; Ndlovu, Dudu; Ramkalawon, Pamela; Ndung’u, Thumbi; Wilson, Douglas; Altfeld, Marcus; Carr, William H

    2011-01-01

    Understanding the role of natural killer (NK) cells in human disease pathogenesis is crucial and necessitates study of patient samples directly ex vivo. Manipulation of whole blood by density gradient centrifugation or delays in sample processing due to shipping, however, may lead to artifactual changes in immune response measures. Here, we assessed the impact of density gradient centrifugation and delayed processing of both whole blood and peripheral blood mononuclear cells (PBMC) at multiple timepoints (2–24 hrs) on flow cytometric measures of NK cell frequency, activation status, chemokine receptor expression, and effector functions. We found that density gradient centrifugation activated NK cells and modified chemokine receptor expression. Delays in processing beyond 8 hours activated NK cells in PBMC but not in whole blood. Likewise, processing delays decreased chemokine receptor (CCR4 and CCR7) expression in both PBMC and whole blood. Finally, delays in processing PBMC were associated with a decreased ability of NK cells to degranulate (as measured by CD107a expression) or secrete cytokines (IFN-γ and TNF-α). In summary, our findings suggest that density gradient centrifugation and delayed processing of PBMC can alter measures of clinically relevant NK cell characteristics including effector functions; and therefore should be taken into account in designing clinical research studies. PMID:21255578

  2. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  3. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  4. Laser Doppler Blood Flow Imaging Using a CMOS Imaging Sensor with On-Chip Signal Processing

    Directory of Open Access Journals (Sweden)

    Cally Gill

    2013-09-01

    Full Text Available The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  5. Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.

    Science.gov (United States)

    He, Diwei; Nguyen, Hoang C; Hayes-Gill, Barrie R; Zhu, Yiqun; Crowe, John A; Gill, Cally; Clough, Geraldine F; Morgan, Stephen P

    2013-09-18

    The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  6. Asymptotic tracking and disturbance rejection of the blood glucose regulation system.

    Science.gov (United States)

    Ashley, Brandon; Liu, Weijiu

    2017-07-01

    Type 1 diabetes patients need external insulin to maintain blood glucose within a narrow range from 65 to 108 mg/dl (3.6 to 6.0 mmol/l). A mathematical model for the blood glucose regulation is required for integrating a glucose monitoring system into insulin pump technology to form a closed-loop insulin delivery system on the feedback of the blood glucose, the so-called "artificial pancreas". The objective of this paper is to treat the exogenous glucose from food as a glucose disturbance and then develop a closed-loop feedback and feedforward control system for the blood glucose regulation system subject to the exogenous glucose disturbance. For this, a mathematical model for the glucose disturbance is proposed on the basis of experimental data, and then incorporated into an existing blood glucose regulation model. Because all the eigenvalues of the disturbance model have zero real parts, the center manifold theory is used to establish blood glucose regulator equations. We then use their solutions to synthesize a required feedback and feedforward controller to reject the disturbance and asymptotically track a constant glucose reference of 90  mg/dl. Since the regulator equations are nonlinear partial differential equations and usually impossible to solve analytically, a linear approximation solution is obtained. Our numerical simulations show that, under the linear approximate feedback and feedforward controller, the blood glucose asymptotically tracks its desired level of 90 mg/dl approximately. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Radioprotective action of beta-carotin and vitamin A, C and E complexes at reproductive system and indices of antioxidant system in male rat blood and liver

    International Nuclear Information System (INIS)

    Vereshchako, G.G.; Konoplya, E.F.; Khodosovskaya, A.M.; Rutkovskaya, Zh.A.

    2008-01-01

    Effects of total irradiation in low dose at the state of rat mail reproductive system, lipid peroxidation processes and antioxidant system in rat blood and liver tissues as well as radioprotective capacity of beta-carotin with vitamin A, C and E complexes were investigated. It was established that injection of this substances to rat's organism one day before irradiation in 1.0 Gy dose led to normalization of spermatogenic cells number, increase of nucleic acids content in testes and significant improvement of antioxidant status of blood and liver tissue. (authors)

  8. 21 CFR 640.16 - Processing.

    Science.gov (United States)

    2010-04-01

    ... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the timeframe specified in the directions for use for the blood collecting, processing, and storage system used, Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to...

  9. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  10. An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

    Science.gov (United States)

    Yamazaki, K; Litwak, P; Tagusari, O; Mori, T; Kono, K; Kameneva, M; Watach, M; Gordon, L; Miyagishima, M; Tomioka, J; Umezu, M; Outa, E; Antaki, J F; Kormos, R L; Koyanagi, H; Griffith, B P

    1998-06-01

    A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).

  11. A system for oxygen-15 labeled blood for medical applications

    International Nuclear Information System (INIS)

    Subramanyam, R.; Bucelewicz, W.M.; Hoop, B. Jr.; Jones, S.C.

    1977-01-01

    Oxygen-15 labeled compounds in blood have been used successfully for cerebral circulation and cerebral oxygen metabolism measurements. The present paper describes a system for the rapid sequential production of 15 O-HgB, C 15 O-Hgb and H 2 15 O in blood under sterile and pyrogen-free conditions. A tonometer has been adopted for labeling blood without hemolysis and foam production. (author)

  12. Code development of the national hemovigilance system and expansion strategies for hospital blood banks

    Directory of Open Access Journals (Sweden)

    Kim Jeongeun

    2012-01-01

    Full Text Available Objectives : The aims of this study were to develop reportable event codes that are applicable to the national hemovigilance systems for hospital blood banks, and to present expansion strategies for the blood banks. Materials and Methods : The data were obtained from a literature review and expert consultation, followed by adding to and revising the established hemovigilance code system and guidelines to develop reportable event codes for hospital blood banks. The Medical Error Reporting System-Transfusion Medicine developed in the US and other codes of reportable events were added to the Korean version of the Biologic Products Deviation Report (BPDR developed by the Korean Red Cross Blood Safety Administration, then using these codes, mapping work was conducted. We deduced outcomes suitable for practice, referred to the results of the advisory councils, and conducted a survey with experts and blood banks practitioners. Results : We developed reportable event codes that were applicable to hospital blood banks and could cover blood safety - from blood product safety to blood transfusion safety - and also presented expansion strategies for hospital blood banks. Conclusion : It was necessary to add 10 major categories to the blood transfusion safety stage and 97 reportable event codes to the blood safety stage. Contextualized solutions were presented on 9 categories of expansion strategies of hemovigilance system for the hospital blood banks.

  13. Microfluidic Devices for Blood Fractionation

    Directory of Open Access Journals (Sweden)

    Chwee Teck Lim

    2011-07-01

    Full Text Available Blood, a complex biological fluid, comprises 45% cellular components suspended in protein rich plasma. These different hematologic components perform distinct functions in vivo and thus the ability to efficiently fractionate blood into its individual components has innumerable applications in both clinical diagnosis and biological research. Yet, processing blood is not trivial. In the past decade, a flurry of new microfluidic based technologies has emerged to address this compelling problem. Microfluidics is an attractive solution for this application leveraging its numerous advantages to process clinical blood samples. This paper reviews the various microfluidic approaches realized to successfully fractionate one or more blood components. Techniques to separate plasma from hematologic cellular components as well as isolating blood cells of interest including certain rare cells are discussed. Comparisons based on common separation metrics including efficiency (sensitivity, purity (selectivity, and throughput will be presented. Finally, we will provide insights into the challenges associated with blood-based separation systems towards realizing true point-of-care (POC devices and provide future perspectives.

  14. A novel system for providing compatible blood to patients during surgery: "self-service" electronic blood banking by nursing staff.

    Science.gov (United States)

    Cheng, G; Chiu, D S; Chung, A S; Wong, H F; Chan, M W; Lui, Y K; Choy, F M; Chan, J C; Chan, A H; Lam, S T; Fan, T C

    1996-04-01

    A good blood bank must be able to provide compatible blood units promptly to operating room patients with minimal wastage. A "self-service" by nursing staff blood banking system that is safe, efficient, and well-accepted has been developed. Specific blood units are no longer assigned to surgical patients who have a negative pretransfusion antibody screen, irrespective of the type of surgery. A computer-generated list of the serial numbers of all group-identical blood units currently in the blood bank inventory is provided for each patient. The units themselves are not labeled with a patient's name. The group O list will be provided for group O patients, the group A list for group A patients, and so forth. Should the patient require transfusion during surgery, the operating room nurses go to the refrigerator, remove any group-identical unit, and check the serial number of the unit against the serial numbers on the patient's list. If the serial number is on that list, the blood bank will accept responsibility for compatibility. The system was implemented in 1995. Since implementation, a total of 2154 patients have undergone operations at this hospital. Thirty-two patients received more than 10 units of red cells each. There were no transfusion errors. The crossmatch-to-transfusion ratio was reduced from 1.67 to 1.12. Turnaround time for supplying additional or urgent units to patients in operating room was shortened from 33 to 2.5 minutes. There was no incidence of a blood unit's serial number not being on the list. Work by nurses and technical staff was reduced by nearly 50 percent. The "self-service" (by nursing staff) blood banking system described is safe and efficient. It saves staff time and can be easily set up.

  15. Coded Ultrasound for Blood Flow Estimation Using Subband Processing

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Nielsen, Michael Bachamnn

    2008-01-01

    the excitation signal is broadband and has good spatial resolution after pulse compression. This means that time can be saved by using the same data for B-mode imaging and blood flow estimation. Two different coding schemes are used in this paper, Barker codes and Golay codes. The performance of the codes......This paper investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband coded...... signals are used to increase SNR, followed by subband processing. The received broadband signal is filtered using a set of narrow-band filters. Estimating the velocity in each of the bands and averaging the results yields better performance compared with what would be possible when transmitting a narrow...

  16. Circulating Blood eNOS Contributes to the Regulation of Systemic Blood Pressure and Nitrite Homeostasis

    Science.gov (United States)

    Wood, Katherine C.; Cortese-Krott, Miriam M.; Kovacic, Jason C.; Noguchi, Audrey; Liu, Virginia B.; Wang, Xunde; Raghavachari, Nalini; Boehm, Manfred; Kato, Gregory J.; Kelm, Malte; Gladwin, Mark T.

    2013-01-01

    Objective Mice genetically deficient in endothelial nitric oxide synthase (eNOS−/−) are hypertensive with lower circulating nitrite levels, indicating the importance of constitutively produced nitric oxide (NO•) to blood pressure regulation and vascular homeostasis. While the current paradigm holds that this bioactivity derives specifically from expression of eNOS in endothelium, circulating blood cells also express eNOS protein. A functional red cell eNOS that modulates vascular NO• signaling has been proposed. Approach and Results To test the hypothesis that blood cells contribute to mammalian blood pressure regulation via eNOS-dependent NO• generation, we cross-transplanted WT and eNOS−/− mice, producing chimeras competent or deficient for eNOS expression in circulating blood cells. Surprisingly, we observed a significant contribution of both endothelial and circulating blood cell eNOS to blood pressure and systemic nitrite levels, the latter being a major component of the circulating NO• reservoir. These effects were abolished by the NOS inhibitor L-NAME and repristinated by the NOS substrate L-Arginine, and were independent of platelet or leukocyte depletion. Mouse erythrocytes were also found to carry an eNOS protein and convert 14C-Arginine into 14C-Citrulline in a NOS-dependent fashion. Conclusions These are the first studies to definitively establish a role for a blood borne eNOS, using cross transplant chimera models, that contributes to the regulation of blood pressure and nitrite homeostasis. This work provides evidence suggesting that erythrocyte eNOS may mediate this effect. PMID:23702660

  17. Automated image processing method for the diagnosis and classification of malaria on thin blood smears.

    Science.gov (United States)

    Ross, Nicholas E; Pritchard, Charles J; Rubin, David M; Dusé, Adriano G

    2006-05-01

    Malaria is a serious global health problem, and rapid, accurate diagnosis is required to control the disease. An image processing algorithm to automate the diagnosis of malaria on thin blood smears is developed. The image classification system is designed to positively identify malaria parasites present in thin blood smears, and differentiate the species of malaria. Images are acquired using a charge-coupled device camera connected to a light microscope. Morphological and novel threshold selection techniques are used to identify erythrocytes (red blood cells) and possible parasites present on microscopic slides. Image features based on colour, texture and the geometry of the cells and parasites are generated, as well as features that make use of a priori knowledge of the classification problem and mimic features used by human technicians. A two-stage tree classifier using backpropogation feedforward neural networks distinguishes between true and false positives, and then diagnoses the species (Plasmodium falciparum, P. vivax, P. ovale or P. malariae) of the infection. Malaria samples obtained from the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand Medical School are used for training and testing of the system. Infected erythrocytes are positively identified with a sensitivity of 85% and a positive predictive value (PPV) of 81%, which makes the method highly sensitive at diagnosing a complete sample provided many views are analysed. Species were correctly determined for 11 out of 15 samples.

  18. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

    Science.gov (United States)

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-12-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery-powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring.

  19. Using an integrated automated system to optimize retention and increase frequency of blood donations.

    Science.gov (United States)

    Whitney, J Garrett; Hall, Robert F

    2010-07-01

    This study examines the impact of an integrated, automated phone system to reinforce retention and increase frequency of donations among blood donors. Cultivated by incorporating data results over the past 7 years, the system uses computerized phone messaging to contact blood donors with individualized, multilevel notifications. Donors are contacted at planned intervals to acknowledge and recognize their donations, informed where their blood was sent, asked to participate in a survey, and reminded when they are eligible to donate again. The report statistically evaluates the impact of the various components of the system on donor retention and blood donations and quantifies the fiscal advantages to blood centers. By using information and support systems provided by the automated services and then incorporating the phlebotomists and recruiters to reinforce donor retention, both retention and donations will increase. © 2010 American Association of Blood Banks.

  20. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  1. Impact of partial pressure of oxygen in blood samples on the performance of systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-03-01

    The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.

  2. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  3. Automated processing of whole blood samples into microliter aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W W; Walker, W A

    1988-01-01

    A rotor that accepts and automatically processes a bulk aliquot of a single blood sample into multiple aliquots of plasma has been designed and built. The rotor consists of a central processing unit, which includes a disk containing eight precision-bore capillaries. By varying the internal diameters of the capillaries, aliquot volumes ranging 1 to 10 mul can be prepared. In practice, an unmeasured volume of blood is placed in a centre well, and, as the rotor begins to spin, is moved radially into a central annular ring where it is distributed into a series of processing chambers. The rotor is then spun at 3000 rpm for 10 min. When the centrifugal field is removed by slowly decreasing the rotor speed, an aliquot of plasma is withdrawn by capillary action into each of the capillary tubes. The disk containing the eight measured aliquots of plasma is subsequently removed and placed in a modifed rotor for conventional centrifugal analysis. Initial evaluation of the new rotor indicates that it is capable of producing discrete, microliter volumes of plasma with a degree of accuracy and precision approaching that of mechanical pipettes.

  4. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  5. Computational simulation of a non-newtonian model of the blood separation process.

    Science.gov (United States)

    De Gruttola, Sandro; Boomsma, Kevin; Poulikakos, Dimos

    2005-12-01

    The aim of this work is to construct a computational fluid dynamics model capable of simulating the transient non-Newtonian process of apheresis. A Lagrangian-Eulerian model has been developed which tracks the blood particles within a two-dimensional flow configuration. Within the Eulerian method, the fluid mass and momentum conservation equations within the separator are solved using the density and the viscosity is calculated from the blood particle concentrations. Subsequently, the displacement of the blood particles is calculated with a Lagrangian method. Hawksley's model for the density of supensions is used in the variable density calculation. The viscosity is calculated with two models based on Vand's rigid particle suspension viscosity concepts, followed by the flow field calculation in the separator. Simulations were performed for various inlet hematocrit values and separator lengths. The simulations are in satisfactory agreement with experimental results reported in literature, indicating a complete separation of plasma and red blood cells (RBCs), as well as nearly complete separation of red blood cells and platelets. No hemolysis was observed in the simulations because the shear rate remained under the critical value of 150 N/m2.

  6. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  7. Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system

    International Nuclear Information System (INIS)

    Weinstein, M.P.; Mirrett, S.; Reimer, L.G.; Reller, L.B.

    1989-01-01

    In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield of streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory

  8. Hepatobiliary system functional analysis by blood flow and clearance delay model

    International Nuclear Information System (INIS)

    Aboltins, A.; Reinholds, E.

    2002-01-01

    A mathematical model for describing liver uptake-excretion is developed and approved. Model is based on different timing delays in hepatobiliary and blood flow system elements. Series of scintigraphic images with 99m Tc-mebrofenins or 99m Tc-HIDA taken with standard nuclear medicine gamma camera are used as the real data for calculations. The time-activity curves are obtained from many regions of human body - heart, liver, gallbladder, spleen, aorta, vein, etc. Both first pass and dynamic acquisition data are used. Results are calculated using real system parameters and compared to real scintigraphy data. Mathematical simulations are made to show difference of hepatobiliary system function at three main points: normal function, good blood flow with bad hepatic function and bad blood flow with good hepatic function. (authors)

  9. Continuous blood pressure recordings simultaneously with functional brain imaging: studies of the glymphatic system

    Science.gov (United States)

    Zienkiewicz, Aleksandra; Huotari, Niko; Raitamaa, Lauri; Raatikainen, Ville; Ferdinando, Hany; Vihriälä, Erkki; Korhonen, Vesa; Myllylä, Teemu; Kiviniemi, Vesa

    2017-03-01

    The lymph system is responsible for cleaning the tissues of metabolic waste products, soluble proteins and other harmful fluids etc. Lymph flow in the body is driven by body movements and muscle contractions. Moreover, it is indirectly dependent on the cardiovascular system, where the heart beat and blood pressure maintain force of pressure in lymphatic channels. Over the last few years, studies revealed that the brain contains the so-called glymphatic system, which is the counterpart of the systemic lymphatic system in the brain. Similarly, the flow in the glymphatic system is assumed to be mostly driven by physiological pulsations such as cardiovascular pulses. Thus, continuous measurement of blood pressure and heart function simultaneously with functional brain imaging is of great interest, particularly in studies of the glymphatic system. We present our MRI compatible optics based sensing system for continuous blood pressure measurement and show our current results on the effects of blood pressure variations on cerebral brain dynamics, with a focus on the glymphatic system. Blood pressure was measured simultaneously with near-infrared spectroscopy (NIRS) combined with an ultrafast functional brain imaging (fMRI) sequence magnetic resonance encephalography (MREG, 3D brain 10 Hz sampling rate).

  10. Accuracy and precision evaluation of seven self-monitoring blood glucose systems.

    Science.gov (United States)

    Kuo, Chih-Yi; Hsu, Cheng-Teng; Ho, Cheng-Shiao; Su, Ting-En; Wu, Ming-Hsun; Wang, Chau-Jong

    2011-05-01

    Self-monitoring blood glucose (SMBG) systems play a critical role in management of diabetes. SMBG systems should at least meet the minimal requirement of the World Health Organization's ISO 15197:2003. For tight glycemic control, a tighter accuracy requirement is needed. Seven SMBG systems were evaluated for accuracy and precision: Bionime Rightest(™) GM550 (Bionime Corp., Dali City, Taiwan), Accu-Chek(®) Performa (Roche Diagnostics, Indianapolis, IN), OneTouch(®) Ultra(®)2 (LifeScan Inc., Milpitas, CA), MediSense(®) Optium(™) Xceed (Abbott Diabetes Care Inc., Alameda, CA), Medisafe (TERUMO Corp., Tokyo, Japan), Fora(®) TD4227 (Taidac Technology Corp., Wugu Township, Taiwan), and Ascensia Contour(®) (Bayer HealthCare LLC, Mishawaka, IN). The 107 participants (44 men and 63 women) were between 23 and 91 years old. The analytical results of seven SMBG systems were compared with those of plasma analyzed with the hexokinase method (Olympus AU640, Olympus America Inc., Center Valley, PA). The imprecision of the seven blood glucose meters ranged from 1.1% to 4.7%. Three of the seven blood glucose meters (42.9%) fulfilled the minimum accuracy criteria of ISO 15197:2003. The mean absolute relative error value for each blood glucose meter was calculated and ranged from 6.5% to 12.0%. More than 40% of evaluated SMBG systems meet the minimal accuracy criteria requirement of ISO 15197:2003. However, considering tighter criteria for accuracy of ±15%, only the Bionime Rightest GM550 meets this requirement. Because SMBG systems play a critical role in management of diabetes, manufacturers have to strive to improve accuracy and precision and to ensure the good quality of blood glucose meters and test strips.

  11. Effectiveness of a Novel Specimen Collection System in Reducing Blood Culture Contamination Rates.

    Science.gov (United States)

    Bell, Mary; Bogar, Catherine; Plante, Jessica; Rasmussen, Kristen; Winters, Sharon

    2018-04-20

    False-positive blood-culture results due to skin contamination of samples remain a persistent problem for health care providers. Our health system recognized that our rates of contamination across the 4 emergency department campuses were above the national average. A unique specimen collection system was implemented throughout the 4 emergency departments and became the mandatory way to collect adult blood cultures. The microbiology laboratory reported contamination rates weekly to manage potential problems; 7 months of data are presented here. There was an 82.8% reduction in false positives with the unique specimen collection system compared with the standard method (chi-squared test with Yates correction, 2-tailed, P = 0.0001). Based on the historical 3.52% rate of blood-culture contamination for our health facilities, 2.92 false positives were prevented for every 100 blood cultures drawn, resulting from adoption of the unique specimen collection system as the standard of care. This unique collection system can reduce the risk of blood culture contamination significantly and is designed to augment, rather than replace, the standard phlebotomy protocol already in use in most health care settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Portable regional cerebral blood flow system based on IBM PC/AT and microprocessor electronics

    International Nuclear Information System (INIS)

    Mun, S.K.; Mun, I.K.; Petite, J.; Cohan, S.L.; Fahey, F.H.

    1986-01-01

    A portable 16-channel reginal cerebral blood flow (rCBF) measuring system has been developed using an IBM PC/AT and new microelectronics to improve processing speed and portability. The detector electronics were developed by Scan Detectronics A/S of Denmark. The counter module contains 18 16-bit counters, each programmable in four different modes. The rate meter has three independent microprocessor controllers for rate meter functions, window controller, and channel controller. The detector electronics and detection parameters can be fully controlled by the host PC/AT. The menu-driven system (Better Basic) assists the operator at each step. The collected data from 16 channels can be processed automatically or postprocessed using more flexible and sophisticated techniques within 20 minutes. The headgear holding 16 sodium iodide detectors is fabricated by modifying a motorcycle helmet

  13. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members.

    Science.gov (United States)

    Närhi, M; Natri, O; Desbois, I; Kinggaard Holm, D; Galea, G; Aranko, K; Korhonen, M; Nordstrom, K

    2013-11-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization. An online questionnaire was used for data collection in 2011, and 43 replies were received covering 71 product answers from 13 countries. Estimated percentages of tissue and cell banking covered by EBA member blood banks as a proportion of all collections of each individual country varied markedly. There were also major differences in the amounts of products collected and discarded and in proportions tissues provided for grafting. However, discarding of certain collections also reflects the practice of increasing the likelihood of the very best units being used for transplantation. Harmonization of possible practices should focus on matching supply with demand and on identifying the most efficient operators. This could allow for the development of practices for minimizing unnecessary collections. © 2013 International Society of Blood Transfusion.

  14. A de novo transcriptome of the Malpighian tubules in non-blood-fed and blood-fed Asian tiger mosquitoes Aedes albopictus: insights into diuresis, detoxification, and blood meal processing

    Directory of Open Access Journals (Sweden)

    Carlos J. Esquivel

    2016-03-01

    Full Text Available Background. In adult female mosquitoes, the renal (Malpighian tubules play an important role in the post-prandial diuresis, which removes excess ions and water from the hemolymph of mosquitoes following a blood meal. After the post-prandial diuresis, the roles that Malpighian tubules play in the processing of blood meals are not well described. Methods. We used a combination of next-generation sequencing (paired-end RNA sequencing and physiological/biochemical assays in adult female Asian tiger mosquitoes (Aedes albopictus to generate molecular and functional insights into the Malpighian tubules and how they may contribute to blood meal processing (3–24 h after blood ingestion. Results/Discussion. Using RNA sequencing, we sequenced and assembled the first de novo transcriptome of Malpighian tubules from non-blood-fed (NBF and blood-fed (BF mosquitoes. We identified a total of 8,232 non-redundant transcripts. The Malpighian tubules of NBF mosquitoes were characterized by the expression of transcripts associated with active transepithelial fluid secretion/diuresis (e.g., ion transporters, water channels, V-type H+-ATPase subunits, xenobiotic detoxification (e.g., cytochrome P450 monoxygenases, glutathione S-transferases, ATP-binding cassette transporters, and purine metabolism (e.g., xanthine dehydrogenase. We also detected the expression of transcripts encoding sodium calcium exchangers, G protein coupled-receptors, and septate junctional proteins not previously described in mosquito Malpighian tubules. Within 24 h after a blood meal, transcripts associated with active transepithelial fluid secretion/diuresis exhibited a general downregulation, whereas those associated with xenobiotic detoxification and purine catabolism exhibited a general upregulation, suggesting a reinvestment of the Malpighian tubules’ molecular resources from diuresis to detoxification. Physiological and biochemical assays were conducted in mosquitoes and isolated

  15. Modelling of the Blood Coagulation Cascade in an In Vitro Flow System

    DEFF Research Database (Denmark)

    Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.

    2010-01-01

    We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade....

  16. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    OpenAIRE

    F. Majlessi; S. Ghafari; A. Rahimi-Foroushani M. Maghsoodlou

    2008-01-01

    The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sec...

  17. White blood cells identification system based on convolutional deep neural learning networks.

    Science.gov (United States)

    Shahin, A I; Guo, Yanhui; Amin, K M; Sharawi, Amr A

    2017-11-16

    White blood cells (WBCs) differential counting yields valued information about human health and disease. The current developed automated cell morphology equipments perform differential count which is based on blood smear image analysis. Previous identification systems for WBCs consist of successive dependent stages; pre-processing, segmentation, feature extraction, feature selection, and classification. There is a real need to employ deep learning methodologies so that the performance of previous WBCs identification systems can be increased. Classifying small limited datasets through deep learning systems is a major challenge and should be investigated. In this paper, we propose a novel identification system for WBCs based on deep convolutional neural networks. Two methodologies based on transfer learning are followed: transfer learning based on deep activation features and fine-tuning of existed deep networks. Deep acrivation featues are extracted from several pre-trained networks and employed in a traditional identification system. Moreover, a novel end-to-end convolutional deep architecture called "WBCsNet" is proposed and built from scratch. Finally, a limited balanced WBCs dataset classification is performed through the WBCsNet as a pre-trained network. During our experiments, three different public WBCs datasets (2551 images) have been used which contain 5 healthy WBCs types. The overall system accuracy achieved by the proposed WBCsNet is (96.1%) which is more than different transfer learning approaches or even the previous traditional identification system. We also present features visualization for the WBCsNet activation which reflects higher response than the pre-trained activated one. a novel WBCs identification system based on deep learning theory is proposed and a high performance WBCsNet can be employed as a pre-trained network. Copyright © 2017. Published by Elsevier B.V.

  18. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  19. Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor

    DEFF Research Database (Denmark)

    Lagerberg, Johan W; Salado-Jimena, Jose A; Löf, Helena

    2013-01-01

    The Reveos system (Terumo BCT) is a fully automated device able to process four whole blood (WB) units simultaneously into a plasma unit, a red blood cell (RBC) unit, and an interim platelet (PLT) unit (IPU). Multiple IPUs can be pooled to form a transfusable PLT product. The aim of our study...... was to evaluate the quality of components made with the Reveos system from either fresh (2-8 hr) or overnight-held WB....

  20. Changes in the blood system after extracorporeal radiation

    International Nuclear Information System (INIS)

    Bobkov, Yu.I.; Yalikov, V.Ya.; Belopol'skij, A.A.; Alekseeva, L.M.; Apollonova, L.A.; Babayan, S.S.; Burkov, I.M.; Vasina, T.A.

    1985-01-01

    The effect of singles extracorporal blood irradiation (ECBI) on cellular and biochemical blood composition, activity of non specific immunity factors has been studied using no breed dogs. A shunt of plastic tube has been superimposed between the femoral artery and vein of the anesthetized animals and during 3h blood irradiation has been carried out for creating dose load from 6.0 to 12.0 Gy. It has been found that hematologic factors upon ECBI are changed unambiguously. Hemoglobin content and hematocrit are increased after irradiation. ESR factor somewhat increases during 7 days then it decreases, attainig 44% of the initial one by the end of the experiment. During 7 days upon ECBI a strongly pronounced leukocytosis is developed. Erythrocytes content for certain is increased on the 3-rd, 5-th and 7-th weeks of the experiment, respectively by 15, 17 and 31%. The change in the quantity of erythrocytes is accompanied by reconstruction in them of energy processes revealed on changing G-6-EDG and transketolaze activity. Simultaneously nucleic acids quantity in blood is increased in animals. In the course of 7-30 days upon irradiation the change of activity of a series of factors of natural immunity such as activity of lysozymb, β lysines content activity of β lytic properties is observed. When administering penicillin the increase of antibiotic activity in irradiated blood is pointed out. The data obtained in the authors opinion show the prospects in using the ECBI method for stimulation in organism of non specific protective mechanisms

  1. Optimized processing of growth factor mobilized peripheral blood CD34+ products by counterflow centrifugal elutriation.

    Science.gov (United States)

    Tran, Chy-Anh; Torres-Coronado, Monica; Gardner, Agnes; Gu, Angel; Vu, Hieu; Rao, Anitha; Cao, Lan-Feng; Ahmed, Amira; Digiusto, David

    2012-05-01

    Cell separation by counterflow centrifugal elutriation has been described for the preparation of monocytes for vaccine applications, but its use in other current good manufacturing practice (cGMP) operations has been limited. In this study, growth factor-mobilized peripheral blood progenitor cell products were collected from healthy donors and processed by elutriation using a commercial cell washing device. Fractions were collected for each product as per the manufacturer's instructions or using a modified protocol developed in our laboratory. Each fraction was analyzed for cell count, viability, and blood cell differential. Our data demonstrate that, using standard elutriation procedures, >99% of red blood cells and platelets were removed from apheresis products with high recoveries of total white blood cells and enrichment of CD34+ cells in two of five fractions. With modification of the basic protocol, we were able to collect all of the CD34+ cells in a single fraction. The CD34-enriched fractions were formulated, labeled with a ferromagnetic antibody to CD34, washed using the Elutra device, and transferred directly to a magnetic bead selection device for further purification. CD34+ cell purities from the column were extremely high (98.7 ± 0.9%), and yields were typical for the device (55.7 ± 12.3%). The processes were highly automated and closed from receipt of the apheresis product through formulation of target-enriched cell fractions. Thus, elutriation is a feasible method for the initial manipulations associated with primary blood cell therapy products and supports cGMP and current good tissue practice-compliant cell processing.

  2. Liver-inherent immune system: its role in blood-stage malaria.

    Science.gov (United States)

    Wunderlich, Frank; Al-Quraishy, Saleh; Dkhil, Mohamed A

    2014-01-01

    The liver is well known as that organ which is obligately required for the intrahepatocyte development of the pre-erythrocytic stages of the malaria-causative agent Plasmodium. However, largely neglected is the fact that the liver is also a central player of the host defense against the morbidity- and mortality-causing blood stages of the malaria parasites. Indeed, the liver is equipped with a unique immune system that acts locally, however, with systemic impact. Its main "antipodal" functions are to recognize and to generate effective immunoreactivity against pathogens on the one hand, and to generate tolerance to avoid immunoreactivity with "self" and harmless substances as dietary compounds on the other hand. This review provides an introductory survey of the liver-inherent immune system: its pathogen recognition receptors including Toll-like receptors (TLRs) and its major cell constituents with their different facilities to fight and eliminate pathogens. Then, evidence is presented that the liver is also an essential organ to overcome blood-stage malaria. Finally, we discuss effector responses of the liver-inherent immune system directed against blood-stage malaria: activation of TLRs, acute phase response, phagocytic activity, cytokine-mediated pro- and anti-inflammatory responses, generation of "protective" autoimmunity by extrathymic T cells and B-1 cells, and T cell-mediated repair of liver injuries mainly produced by malaria-induced overreactions of the liver-inherent immune system.

  3. Barriers and motivators to blood and cord blood donations in young African-American women.

    Science.gov (United States)

    Grossman, Brenda; Watkins, Andre R; Fleming, Faye; Debaun, Michael R

    2005-03-01

    The primary aim of this study was to assess potential barriers and motivators to blood and cord blood donation among African-American women. A telephone survey of African-American women, ages 18-30 years, in the St. Louis metropolitan area was performed. The survey was administered by trained telemarketing personnel using a Computer-Assisted Direct Interview (CADI) system. One hundred sixty-two women were surveyed. Common barriers to blood donation were inconvenience of donor sites (19%), fear of needles (16%), and too much time required to donate (15%). Potential motivators were increasing awareness of need for blood (43%), increasing the number of convenient donor locations (19%), and encouragement by spiritual leaders to have blood drives at their church (17%). Lack of awareness was the only identified barrier to cord blood donation. Most women surveyed (88%) indicated that they definitely or probably would donate cord blood. Strategies to increase the proportion of African-American blood and cord blood donations may include educating potential donors about the process and benefits of donation to particular patient populations and engaging church leadership in supporting blood and cord blood donations.

  4. Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.

    Science.gov (United States)

    Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong

    2018-01-01

    With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.

  5. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring

    OpenAIRE

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-01-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery–powered electrochemical twin channels (ETCs). The ...

  6. Bio-Inspiered Blood-Contacting Materials Elaborated For The Heart Assist System

    Directory of Open Access Journals (Sweden)

    Major R.

    2015-09-01

    Full Text Available The paper presents the main achievements of the author on the development of blood contacting materials. The main objective of the work is to elaborate materials dedicated for the heart support systems. Appropriately designed biomaterial surfaces enable fully controlled cellular differentiation, proliferation, and even restoration of the tissue structure on solids. The paper presents two approaches to modify the surface, which can control the life processes of tissue. The first solution considers the topography in the form of cell niches. The main objective of the study is a modified surface of thin films deposited on the polymer substrate constituting the microenvironment for the cells caused by residual stress and optimized stiffness of the surface using the plasma methods. The research hypothesis was the plasma surface modification method generating a controlled contribution of residual stress in the coating affect the surface topography in the form of nano- wrinkles similar to the niches in the tissue environment. Topography and stiffness of the surface coating allows the targeted cellular differentiation. The properly formed surface topography effectively inhibits blood clotting processes. The second solution considers implementation of self-organizing feature of extracellular matrix like coatings and selective cell mobilization. The multiscale analysis and phenomenologic description were performed to experimental research. For this purpose, the deposition method was based on electrostatic interactions in polyelectrolytes. This type of cell-polymer structure imitate the native structures.

  7. Prevalence of antibodies to a new histo-blood system: the FORS system.

    Science.gov (United States)

    Jesus, Carlos; Hesse, Camilla; Rocha, Clara; Osório, Nádia; Valado, Ana; Caseiro, Armando; Gabriel, António; Svensson, Lola; Moslemi, Ali-Reza; Siba, Wafa Abu; Srour, Mahmoud A; Pereira, Cristina; Tomaz, Jorge; Teixeira, Paulo; Mendes, Fernando

    2018-02-01

    In 1987, three unrelated English families were reported with a putative blood subgroup called A pae . Swedish researchers later found evidence leading to abolishment of the A pae subgroup and establishment instead of the FORS blood group system (System 31 - ISBT, 2012). It is important to know the prevalence of antibodies in order to make the best decisions in transfusion medicine. Cells expressing the Forssman saccharide, such as sheep erythrocytes, are needed to detect the anti-Forssman antibody. The aim of this study was to define the prevalence of human anti-Forssman antibody. Plasma samples from 800 individuals were studied. Sheep erythrocytes or Forssman "kodecytes" were mixed with the plasma samples using the tube technique. Plasma from an A pae individual was used as a negative control and monoclonal anti-Forssman antibody (M1/22.25.8HL cell line supernatant) was used as the positive control. Of the 800 individuals tested, one was negative for the presence of anti-Forssman antibody. We compared the anti-Forssman antibody reaction pattern between genders and found that males have weaker reactions than females, both at room temperature (p=0.026) and at 37 °C (p=0.043). We also investigated the reaction pattern of anti-Forssman antibody in relation to ABO and Rh blood group types without finding any significant differences. Sheep erythrocytes are suitable for searching for human anti-Forssman antibody. The quantity of anti-Forssman antibodies in plasma is higher in females than in males. In the population (n=800) studied here, we found one individual lacking the anti-Forssman antibody. These results contribute to the data already published, confirming that FORS is a rare blood group.

  8. Mycobacterium tuberculosis bacteremia detected by the Isolator lysis-centrifugation blood culture system.

    OpenAIRE

    Kiehn, T E; Gold, J W; Brannon, P; Timberger, R J; Armstrong, D

    1985-01-01

    Mycobacterium tuberculosis was detected by the Isolator lysis-centrifugation blood culture system from the blood of a patient with tuberculosis of the breast. The organism also grew on conventional laboratory media inoculated with pleural fluid from the patient.

  9. Dynamic expression of leukocyte innate immune genes in whole blood from horses with lipopolysaccharide-induced acute systemic inflammation

    DEFF Research Database (Denmark)

    Vinther, Anne Mette L.; Skovgaard, Kerstin; Heegaard, Peter M. H.

    2015-01-01

    Background: In horses, insights into the innate immune processes in acute systemic inflammation are limited even though these processes may be highly important for future diagnostic and therapeutic advances in high-mortality disease conditions as the systemic inflammatory response syndrome (SIRS......) and sepsis. Therefore, the aim of this study was to investigate the expression of 31 selected blood leukocyte immune genes in an equine model of acute systemic inflammation to identify significantly regulated genes and to describe their expression dynamics during a 24-h experimental period. Systemic...... were compared with baseline levels. Results: Systemic inflammation was confirmed by the presence of clinical and hematological changes which were consistent with SIRS. The clinical response to LPS was transient and brief as all horses except one showed unaltered general demeanor after 24 h. Twenty...

  10. Antioxidant status, immune system, blood metabolites and carcass ...

    African Journals Online (AJOL)

    This experiment was conducted to evaluate the effects of dietary turmeric rhizome powder (TP) on performance, blood metabolite, immune system, antioxidant status, and relative weight of organs in pre and post heat stressed broilers. Two hundred and sixty-four (264) day-old male Arian broiler chicks were randomly ...

  11. [A capillary blood flow velocity detection system based on linear array charge-coupled devices].

    Science.gov (United States)

    Zhou, Houming; Wang, Ruofeng; Dang, Qi; Yang, Li; Wang, Xiang

    2017-12-01

    In order to detect the flow characteristics of blood samples in the capillary, this paper introduces a blood flow velocity measurement system based on field-programmable gate array (FPGA), linear charge-coupled devices (CCD) and personal computer (PC) software structure. Based on the analysis of the TCD1703C and AD9826 device data sheets, Verilog HDL hardware description language was used to design and simulate the driver. Image signal acquisition and the extraction of the real-time edge information of the blood sample were carried out synchronously in the FPGA. Then a series of discrete displacement were performed in a differential operation to scan each of the blood samples displacement, so that the sample flow rate could be obtained. Finally, the feasibility of the blood flow velocity detection system was verified by simulation and debugging. After drawing the flow velocity curve and analyzing the velocity characteristics, the significance of measuring blood flow velocity is analyzed. The results show that the measurement of the system is less time-consuming and less complex than other flow rate monitoring schemes.

  12. Blood Glutamate Scavenging: Insight into Neuroprotection

    Directory of Open Access Journals (Sweden)

    Alexander Zlotnik

    2012-08-01

    Full Text Available Brain insults are characterized by a multitude of complex processes, of which glutamate release plays a major role. Deleterious excess of glutamate in the brain’s extracellular fluids stimulates glutamate receptors, which in turn lead to cell swelling, apoptosis, and neuronal death. These exacerbate neurological outcome. Approaches aimed at antagonizing the astrocytic and glial glutamate receptors have failed to demonstrate clinical benefit. Alternatively, eliminating excess glutamate from brain interstitial fluids by making use of the naturally occurring brain-to-blood glutamate efflux has been shown to be effective in various animal studies. This is facilitated by gradient driven transport across brain capillary endothelial glutamate transporters. Blood glutamate scavengers enhance this naturally occurring mechanism by reducing the blood glutamate concentration, thus increasing the rate at which excess glutamate is cleared. Blood glutamate scavenging is achieved by several mechanisms including: catalyzation of the enzymatic process involved in glutamate metabolism, redistribution of glutamate into tissue, and acute stress response. Regardless of the mechanism involved, decreased blood glutamate concentration is associated with improved neurological outcome. This review focuses on the physiological, mechanistic and clinical roles of blood glutamate scavenging, particularly in the context of acute and chronic CNS injury. We discuss the details of brain-to-blood glutamate efflux, auto-regulation mechanisms of blood glutamate, natural and exogenous blood glutamate scavenging systems, and redistribution of glutamate. We then propose different applied methodologies to reduce blood and brain glutamate concentrations and discuss the neuroprotective role of blood glutamate scavenging.

  13. A Neural-Network-Based Approach to White Blood Cell Classification

    Directory of Open Access Journals (Sweden)

    Mu-Chun Su

    2014-01-01

    Full Text Available This paper presents a new white blood cell classification system for the recognition of five types of white blood cells. We propose a new segmentation algorithm for the segmentation of white blood cells from smear images. The core idea of the proposed segmentation algorithm is to find a discriminating region of white blood cells on the HSI color space. Pixels with color lying in the discriminating region described by an ellipsoidal region will be regarded as the nucleus and granule of cytoplasm of a white blood cell. Then, through a further morphological process, we can segment a white blood cell from a smear image. Three kinds of features (i.e., geometrical features, color features, and LDP-based texture features are extracted from the segmented cell. These features are fed into three different kinds of neural networks to recognize the types of the white blood cells. To test the effectiveness of the proposed white blood cell classification system, a total of 450 white blood cells images were used. The highest overall correct recognition rate could reach 99.11% correct. Simulation results showed that the proposed white blood cell classification system was very competitive to some existing systems.

  14. The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps.

    Science.gov (United States)

    Yamazaki, K; Mori, T; Tomioka, J; Litwak, P; Antaki, J F; Tagusari, O; Koyanagi, H; Griffith, B P; Kormos, R L

    1997-01-01

    A critical issue facing the development of an implantable, rotary blood pump is the maintenance of an effective seal at the rotating shaft. Mechanical seals are the most versatile type of seal in wide industrial applications. However, in a rotary blood pump, typical seal life is much shorter than required for chronic support. Seal failure is related to adhesion and aggregation of heat denatured blood proteins that diffuse into the lubricating film between seal faces. Among the blood proteins, fibrinogen plays an important role due to its strong propensity for adhesion and low transition temperature (approximately 50 degrees C). Once exposed to temperature exceeding 50 degrees C, fibrinogen molecules fuse together by multi-attachment between heat denatured D-domains. This quasi-polymerized fibrin increases the frictional heat, which proliferates the process into seal failure. If the temperature of the seal faces is maintained well below 50 degrees C, a mechanical seal would not fail in blood. Based on this "Cool-Seal" concept, we developed a miniature mechanical seal made of highly thermally conductive material (SiC), combined with a recirculating purge system. A large supply of purge fluid is recirculated behind the seal face to augment convective heat transfer to maintain the seal temperature below 40 degrees C. It also cools all heat generating pump parts (motor coil, bearing, seal). The purge consumption has been optimized to virtually nil (seal system has now been incorporated into our intraventricular axial flow blood pump (IVAP) and newly designed centrifugal pump. Ongoing in vivo evaluation of these systems has demonstrated good seal integrity for more than 160 days. The Cool-Seal system can be applied to any type of rotary blood pump (axial, diagonal, centrifugal, etc.) and offers a practical solution to the shaft seal problem and heat related complications, which currently limit the use of implantable rotary blood pumps.

  15. [Innovative technology and blood safety].

    Science.gov (United States)

    Begue, S; Morel, P; Djoudi, R

    2016-11-01

    If technological innovations are not enough alone to improve blood safety, their contributions for several decades in blood transfusion are major. The improvement of blood donation (new apheresis devices, RFID) or blood components (additive solutions, pathogen reduction technology, automated processing of platelets concentrates) or manufacturing process of these products (by automated processing of whole blood), all these steps where technological innovations were implemented, lead us to better traceability, more efficient processes, quality improvement of blood products and therefore increased blood safety for blood donors and patients. If we are on the threshold of a great change with the progress of pathogen reduction technology (for whole blood and red blood cells), we hope to see production of ex vivo red blood cells or platelets who are real and who open new conceptual paths on blood safety. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Immunosuppressant therapeutic drug monitoring by LC-MS/MS: workflow optimization through automated processing of whole blood samples.

    Science.gov (United States)

    Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario

    2013-11-01

    Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.

  17. [The blood-brain barrier and drug delivery in the central nervous system].

    Science.gov (United States)

    Loch-Neckel, Gecioni; Koepp, Janice

    2010-08-01

    To provide an updated view of the difficulties due to barriers and strategies used to allow the release of drugs in the central nervous system. The difficulty for the treatment of many diseases of the central nervous system, through the use of intra-venous drugs, is due to the presence of barriers that prevent the release of the same: the blood-brain barrier, blood-cerebro-spinal fluid barrier and the blood-arachnoid barrier. The blood-brain barrier is the main barrier for the transport of drugs in the brain that also acts as a immunologic and metabolic barrier. The endothelial cells of the blood-brain barrier are connected to a junction complex through the interaction of transmembrane proteins that protrude from de inside to the outside, forming a connection between the endothelial cells. The transport of substances to the brain depends on the mechanisms of transport present in the barrier and the diffusion of these compounds also depends on the physicochemical characteristics of the molecule. Some diseases alter the permeability of the blood-brain barrier and thus the passage of drugs. Strategies such as the use of methods for drug delivery in the brain have been investigated. Further details regarding the mechanisms of transport across the blood-brain barrier and the changes in neuropathology would provide important information about the etiology of diseases and lead to better therapeutic strategies.

  18. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  19. Systems biology of stored blood cells: can it help to extend the expiration date?

    Science.gov (United States)

    Paglia, Giuseppe; Palsson, Bernhard Ø; Sigurjonsson, Olafur E

    2012-12-05

    With increasingly stringent regulations regarding deferral and elimination of blood donors it will become increasingly important to extend the expiration date of blood components beyond the current allowed storage periods. One reason for the storage time limit for blood components is that platelets and red blood cells develop a condition called storage lesions during their storage in plastic blood containers. Systems biology provides comprehensive bio-chemical descriptions of organisms through quantitative measurements and data integration in mathematical models. The biological knowledge for a target organism can be translated in a mathematical format and used to compute physiological properties. The use of systems biology represents a concrete solution in the study of blood cell storage lesions, and it may open up new avenues towards developing better storage methods and better storage media, thereby extending the storage period of blood components. This article is part of a Special Issue entitled: Integrated omics. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. The Impact of an Electronic Ordering System on Blood Bank Specimen Rejection Rates.

    Science.gov (United States)

    Forest, Stefanie K; Shirazi, Maryam; Wu-Gall, Charlotte; Stotler, Brie A

    2017-01-01

    To evaluate the impact that an electronic ordering system has on the rate of rejection of blood type and screen testing samples and the impact on the number of ABO blood-type discrepancies over a 4-year period. An electronic ordering system was implemented in May 2011. Rejection rates along with reasons for rejection were tracked between January 2010 and December 2013. A total of 40,104 blood samples were received during this period, of which 706 (1.8%) were rejected for the following reasons: 382 (54.0%) unsigned samples, 235 (33.0%) mislabeled samples, 57 (8.0%) unsigned requisitions, 18 (2.5%) incorrect tubes, and 14 (1.9%) ABO discrepancies. Of the samples, 2.5% were rejected in the year prior to implementing the electronic ordering system compared with 1.2% in the year following implementation ( P  blood sample rejection. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. Implementation of a configurable laboratory information management system for use in cellular process development and manufacturing.

    Science.gov (United States)

    Russom, Diana; Ahmed, Amira; Gonzalez, Nancy; Alvarnas, Joseph; DiGiusto, David

    2012-01-01

    Regulatory requirements for the manufacturing of cell products for clinical investigation require a significant level of record-keeping, starting early in process development and continuing through to the execution and requisite follow-up of patients on clinical trials. Central to record-keeping is the management of documentation related to patients, raw materials, processes, assays and facilities. To support these requirements, we evaluated several laboratory information management systems (LIMS), including their cost, flexibility, regulatory compliance, ongoing programming requirements and ability to integrate with laboratory equipment. After selecting a system, we performed a pilot study to develop a user-configurable LIMS for our laboratory in support of our pre-clinical and clinical cell-production activities. We report here on the design and utilization of this system to manage accrual with a healthy blood-donor protocol, as well as manufacturing operations for the production of a master cell bank and several patient-specific stem cell products. The system was used successfully to manage blood donor eligibility, recruiting, appointments, billing and serology, and to provide annual accrual reports. Quality management reporting features of the system were used to capture, report and investigate process and equipment deviations that occurred during the production of a master cell bank and patient products. Overall the system has served to support the compliance requirements of process development and phase I/II clinical trial activities for our laboratory and can be easily modified to meet the needs of similar laboratories.

  2. Providing Hemostatic and Blood Conservation Options for Jehovah's Witness Patients in a Large Medical System.

    Science.gov (United States)

    Bai, Yu; Castillo, Brian S; Tchakarov, Amanda; Escobar, Miguel A; Cotton, Bryan A; Holcomb, John B; Brown, Robert E

    2016-12-01

    People of the Jehovah's Witness faith believe that they shall "abstain from blood." Because of this belief, we encounter the challenges from Jehovah's Witness patients who actively seek medical care for themselves and their children, but refuse the transfusion of blood products, which may result in increased morbidity and mortality in this patient population. With the development/availability of new hemostatic/coagulation products and the advances in medical technology, we, in collaboration with our clinical colleagues and our local Jehovah's Witness leadership, have developed a clinical guideline comprising medical protocol and surgical strategy for patients refusing blood products. Included in the medical protocol is an informative handout on related details to help treating physicians and patients make informed decisions about transfusion alternatives. Together, we have entered the medical protocol into the entire Memorial Hermann Hospital's electronic system. We report the detailed development and implementation process in order to share our experience and encourage others to develop their own management plan for this patient population. © 2016 by the Association of Clinical Scientists, Inc.

  3. [Pediatric preparations of blood products].

    Science.gov (United States)

    Boulat, C

    2017-09-01

    The transfusion in pediatrics may require specific preparations to adapt to the various characteristics from preterm neonates to big child: weight, immaturity, immune system, blood volume, long and short-term prognosis, and to meet the needs of pathologies related to the perinatal period. The knowledge of the process for preparation, conservation and administration of these particular products shall permit a transfusion in safe conditions by supporting the prescribers in a personalized blood management. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  5. A signal processing application for evaluating self-monitoring blood glucose strategies in a software agent model.

    Science.gov (United States)

    Wang, Zhanle; Paranjape, Raman

    2015-07-01

    We propose the signal processing technique of calculating a cross-correlation function and an average deviation between the continuous blood glucose and the interpolation of limited blood glucose samples to evaluate blood glucose monitoring frequency in a self-aware patient software agent model. The diabetic patient software agent model [1] is a 24-h circadian, self-aware, stochastic model of a diabetic patient's blood glucose levels in a software agent environment. The purpose of this work is to apply a signal processing technique to assist patients and physicians in understanding the extent of a patient's illness using a limited number of blood glucose samples. A second purpose of this work is to determine an appropriate blood glucose monitoring frequency in order to have a minimum number of samples taken that still provide a good understanding of the patient's blood glucose levels. For society in general, the monitoring cost of diabetes is an extremely important issue, and these costs can vary tremendously depending on monitoring approaches and monitoring frequencies. Due to the cost and discomfort associated with blood glucose monitoring, today, patients expect monitoring frequencies specific to their health profile. The proposed method quantitatively assesses various monitoring protocols (from 6 times per day to 1 time per week) in nine predefined categories of patient agents in terms of risk factors of health status and age. Simulation results show that sampling 6 times per day is excessive, and not necessary for understanding the dynamics of the continuous signal in the experiments. In addition, patient agents in certain conditions only need to sample their blood glucose 1 time per week to have a good understanding of the characteristics of their blood glucose. Finally, an evaluation scenario is developed to visualize this concept, in which appropriate monitoring frequencies are shown based on the particular conditions of patient agents. This base line can

  6. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study.

    Science.gov (United States)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular resistance). However, we hypothesise that the heart contributes to the age-related blood pressure progression as well. In the present study we quantified the blood pressure changes in normal aging by using a Windkessel model for the arterial system and the time-varying elastance model for the heart, and compared the simulation results with data from the Framingham Heart Study. Parameters representing arterial changes (resistance and stiffness) during aging were based on literature values, whereas parameters representing cardiac changes were computed through physiological rules (compensated hypertrophy and preservation of end-diastolic volume). When taking into account arterial changes only, the systolic and diastolic pressure did not agree well with the population data. Between 20 and 80 years, systolic pressure increased from 100 to 122 mmHg, and diastolic pressure decreased from 76 to 55 mmHg. When taking cardiac adaptations into account as well, systolic and diastolic pressure increased from 100 to 151 mmHg and decreased from 76 to 69 mmHg, respectively. Our results show that not only the arterial system, but also the heart, contributes to the changes in blood pressure during aging. The changes in arterial properties initiate a systolic pressure increase, which in turn initiates a cardiac remodelling process that further augments systolic pressure and mitigates the decrease in diastolic pressure.

  7. Microbes and blood transfusion

    Directory of Open Access Journals (Sweden)

    Narayan S

    2001-01-01

    Full Text Available Transfusion medicine has been constantly evolving through the years with improved technologies that enhance the capability of identifying existing and newer emerging transfusion transmissible infections (TTI. In spite of the efforts made by blood banks the risk of TTI remains. This article deals with the various steps involved in ensuring blood safety, i.e. donor selection, role of screening donated blood for known and emerging infections, issues and assessment of threat posed by the risk, methodologies employed for testing and possible suggestions to improve transfusion services. While the threat of TTI remains, with a concerted effort of private and government organisations, and co-operation from the diagnostic companies, it is possible to raise the levels of blood safety. A surveillance system is also essential to identify any new agents that might pose a threat in a geographic area and to include them too in the screening process.

  8. FFTF gas processing systems

    International Nuclear Information System (INIS)

    Halverson, T.G.

    1977-01-01

    The design and operation of the two radioactive gas processing systems at the Fast Flux Test Facility (FFTF) exemplifies the concept that will be used in the first generation of Liquid Metal Fast Breeder Reactors (LMFBR's). The two systems, the Radioactive Argon Processing System (RAPS) and the Cell Atmosphere Processing System (CAPS), process the argon and nitrogen used in the FFTF for cover gas on liquid metal systems and as inert atmospheres in steel lined cells housing sodium equipment. The RAPS specifically processes the argon cover gas from the reactor coolant system, providing for decontamination and eventual reuse. The CAPS processes radioactive gasses from inerted cells and other liquid metal cover gas systems, providing for decontamination and ultimate discharge to the atmosphere. The cryogenic processing of waste gas by both systems is described

  9. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    Many patients were referred to Kololo polyclinic laboratory to have their blood glucose checked because the values obtained on the patients' glucose meter systems did not tally with familiar clinical signs and symptoms. This prompted an experimental set up to check glucose meter systems using a larger number of patients.

  10. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  11. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  12. Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.

    Science.gov (United States)

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2018-04-19

    Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

  13. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  14. Comparison of exercise blood pressure measured by technician and an automated system.

    Science.gov (United States)

    Garcia-Gregory, J A; Jackson, A S; Studeville, J; Squires, W G; Owen, C A

    1984-05-01

    We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

  15. Attentive processes, blood lactate and CrossFit®.

    Science.gov (United States)

    Perciavalle, Valentina; Marchetta, Nunzio Salvatore; Giustiniani, Salvatore; Borbone, Carlo; Perciavalle, Vincenzo; Petralia, Maria Cristina; Buscemi, Andrea; Coco, Marinella

    2016-11-01

    To analyze the influences of blood lactate produced during a specific session of CrossFit® on intensity and selectivity of attention. The first was evaluated by measuring the reaction time and the second by analyzing divided attention with a dual task. Fifteen male professionals of CrossFit® volunteered in the study. The training session was the Workout Of the Day (WOD) called 15.5, marked as: 27-21-15-9 repetitions (without recovery) in term of calories measured by using a rowing ergometer (e.g. 27 rowed calories) and in term of barbell full squats (raising a weight of 43 kg for men and of 29.5 kg for women). Blood lactate, blood glucose, reaction time, execution time of a dual task, number of errors and number of omissions were measured at rest, at the conclusion of the session and 15 minutes after its end. The levels of the blood lactate before the start of the session were considerably higher than those which normally occur at rest (CrossFit®, with high levels of blood lactate even at rest, should consequently have attentional performances somewhat limited.

  16. Expression of manganese superoxide dismutase in rat blood, heart and brain during induced systemic hypoxia

    Directory of Open Access Journals (Sweden)

    Septelia I. Wanandi

    2011-02-01

    Full Text Available Background: Hypoxia results in an increased generation of ROS. Until now, little is known about the role of MnSOD - a major endogenous antioxidant enzyme - on the cell adaptation response against hypoxia. The aim of this study was to  determine the MnSOD mRNA expression and levels of specific activity in blood, heart and brain of rats during induced systemic hypoxia.Methods: Twenty-five male Sprague Dawley rats were subjected to systemic hypoxia in an hypoxic chamber (at 8-10% O2 for 0, 1, 7, 14 and 21 days, respectively. The mRNA relative expression of MnSOD was analyzed using Real Time RT-PCR. MnSOD specific activity was determined using xanthine oxidase inhibition assay.Results: The MnSOD mRNA relative expression in rat blood and heart was decreased during early induced systemic hypoxia (day 1 and increased as hypoxia continued, whereas the mRNA expression in brain was increased since day 1 and reached its maximum level at day 7. The result of MnSOD specific activity during early systemic hypoxia was similar to the mRNA expression. Under very late hypoxic condition (day 21, MnSOD specific activity in blood, heart and brain was significantly decreased. We demonstrate a positive correlation between MnSOD mRNA expression and specific activity in these 3 tissues during day 0-14 of induced systemic hypoxia. Furthermore, mRNA expression and specific activity levels in heart strongly correlate with those in blood.Conclusion: The MnSOD expression at early and late phases of induced systemic hypoxia is distinctly regulated. The MnSOD expression in brain differs from that in blood and heart revealing that brain tissue can  possibly survive better from induced systemic hypoxia than heart and blood. The determination of MnSOD expression in blood can be used to describe its expression in heart under systemic hypoxic condition. (Med J Indones 2011; 20:27-33Keywords: MnSOD, mRNA expression, ROS, specific activity, systemic hypoxia

  17. The Chikungunya epidemic in Italy and its repercussion on the blood system.

    Science.gov (United States)

    Liumbruno, Giancarlo Maria; Calteri, Deanna; Petropulacos, Kyriakoula; Mattivi, Andrea; Po, Claudio; Macini, Pierluigi; Tomasini, Ivana; Zucchelli, Paolo; Silvestri, Anna Rita; Sambri, Vittorio; Pupella, Simonetta; Catalano, Liviana; Piccinini, Vanessa; Calizzani, Gabriele; Grazzini, Giuliano

    2008-10-01

    The Chikungunya virus (CHIKV) is transmitted by Aedes mosquitoes and recently caused a massive epidemic on La Réunion Island, in the Indian Ocean. Between July and September 2007 it caused the first autochthonous epidemic outbreak in Europe, in the Region of Emilia-Romagna in the north-east of Italy. After the first reports of an unusually high number of patients with a febrile illness of unknown origin in two contiguous villages, an outbreak investigation was carried out to identify the primary source of infection, the modes of transmission and the dynamics of the epidemic. An active surveillance system was also implemented. Laboratory diagnosis was performed through serology and polymerase chain reaction (PCR) analysis. Blood donation was discontinued in the areas involved from September to October 2007 and specific precautionary blood safety and self-sufficiency measures were adopted by the regional health and blood authorities and the National Blood Centre. An estimate method to early assess the risk of viraemic blood donations by asymptomatic donors was developed, as a tool for "pragmatic" risk assessment and management, aiming at providing a reliable order of magnitude of the mean risk of CHIKV transmission through blood transfusion. Two hundred and seventeen cases of CHIKV infection were identified between 4th July and 28th September. The disease was fairly mild in most of the cases. The precautionary measures adopted in the blood system caused a considerable reduction of the collection of blood components and of the delivery of plasma to the pharmaceutical industry for contract manufacturing. The estimated risk of CHIKV transmission through blood transfusion peaked in the third week of August. ACHIKV epidemic poses considerable problems for public health authorities, who not only need good routine programmes of vector control and epidemiological surveillance but also local and national emergency plans to sustain the blood supply, so as to promptly deal

  18. Precautions and Adverse Reactions during Blood Transfusion

    Science.gov (United States)

    ... the Professional Version Blood Transfusion Overview of Blood Transfusion Blood Donation Process Blood Products Special Blood Donation Procedures ... CORTEF, SOLU-CORTEF Blood Transfusion Overview of Blood Transfusion Blood Donation Process Blood Products Special Blood Donation Procedures ...

  19. Ionizing radiations and blood vessels

    International Nuclear Information System (INIS)

    Vorob'ev, E.I.; Stepanov, R.P.

    1985-01-01

    Data on phenomeology of radiation changes of blood vessels are systemized and the authors' experience is generalyzed. A critical analysis of modern conceptions on processes resulting in vessel structure damage after irradiation, is given. Special attention is paid to reparation and compensation of radiation injury of vessels

  20. Plasma fractionation, a useful means to improve national transfusion system and blood safety: Iran experience.

    Science.gov (United States)

    Cheraghali, A M; Abolghasemi, H

    2009-03-01

    In 1974, the government of Iran established Iranian Blood Transfusion Organization (IBTO) as national and centralized transfusion system. Since then donations of blood may not be remunerated and therapy with blood and its components are free of charges for all Iranian patients. Donations are meticulously screened through interviewing donors and lab testing the donations using serological methods. Currently, Iranian donors donate 1735 00 units of blood annually (donation index: 25/1000 population). Implementation of a highly efficient donor selection programme, including donors interview, establishment of confidential unit exclusion programme and laboratory screening of donated bloods by IBTO have led to seroprevalence rates of 0.41%, 0.12% and 0.004% for HBV, HCV and HIV in donated bloods respectively. Since 2004, IBTO has initiated a programme to enter into a contract fractionation agreement for the surplus of recovered plasma produced in its blood collecting centres. Although IBTO has used this project as a mean to improve national transfusion system through upgrading its quality assurance systems, IBTO fractionation project has played a major role in improving availability of plasma-derived medicines in Iran. During 2006-2007, this project furnished the Iran market with 44% and 14% of its needs to the intravenous immunoglobulin and albumin, respectively. Iranian experience showed that contract fractionation of plasma in countries with organized centralized transfusion system, which lack national plasma fractionation facility, in addition to substantial saving on national health resource and enhancing availability of plasma-derived medicines, could serve as a useful means to improve national blood safety profile.

  1. Development of High Temperature Short Time Vertebrate-Blood Pasteurization Equipment for Tsetse Fly Diets

    Energy Technology Data Exchange (ETDEWEB)

    Moravek, I; Lach, J [Department of Manufacturing Systems, Slovak Technical University Namestie Slobody 17 812 31 Bratislava (Slovakia); Takac, P [Institute of Zoology, SAV, Bratislava (Slovakia)

    2012-07-15

    Tsetse flies feed only on vertebrate blood, but the collection and processing of blood is expensive, it must be stored at -20{sup o}C requiring costly storage rooms and reliable electricity, and it must be irradiated to reduce bacterial contamination. This is tolerable for small colonies, but as colony size increases to service large- scale programmes, the supply and processing of blood becomes critical. Blood is normally collected from cattle at slaughter. This process is necessarily not aseptic, and large-scale collection is only possible where the animals are suspended for bleeding. One alternative to blood decontamination is using the High Temperature Short time Pasteurization (HTST) method. The food processing industry uses pasteurization to reduce bacterial load in a wide range of products. Our previous results indicated that for the control of the blood pasteurization process, to reach satisfactory bacteriological purity and at the same time to prevent the blood from coagulating, it is important to study temperature and time and also some other parameters that could predict blood coagulation. Crucial for blood coagulation is to study blood viscosity. Classical heat exchangers are not suitable for blood pasteurization. In such equipment the blood coagulation depends on temperature and time. Besides the relatively low temperatures, blood is coagulating with cumulative time until total shutdown of blood flow. After a series of experiments we found a solution using microwave systems. To verify the microwave heating concept, we built an experimental workstation. First we verified the accuracy of the applicator design from the aspect of output adaptation to the power source. Also we installed measuring equipment. This system complies with the requirements of quick heating with sufficiently high heat accumulation. By utilizing standard components for the base of the microwave generator, it is possible to markedly reduce the final price of the equipment. (author)

  2. Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture

    International Nuclear Information System (INIS)

    Brannon, P.; Kiehn, T.E.

    1985-01-01

    The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours and Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, were detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures

  3. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients.

    Science.gov (United States)

    Kanadani, Fabio N; Figueiredo, Carlos R; Miranda, Rafaela Morais; Cunha, Patricia Lt; M Kanadani, Tereza Cristina; Dorairaj, Syril

    2015-01-01

    Glaucomatous neuropathy can be a consequence of insufficient blood supply, increase in intraocular pressure (IOP), or other risk factors that diminish the ocular blood flow. To determine the ocular perfusion pressure (OPP) in normal and systemic hypertensive patients. One hundred and twenty-one patients were enrolled in this prospective and comparative study and underwent a complete ophthalmologic examination including slit lamp examination, Goldmann applanation tonometry, stereoscopic fundus examination, and pulsatile ocular blood flow (POBF) measurements. The OPP was calculated as being the medium systemic arterial pressure (MAP) less the IOP. Only right eye values were considered for calculations using Student's t-test. The mean age of the patients was 57.5 years (36-78), and 68.5% were women. There was a statistically significant difference in the OPP of the normal and systemic hypertensive patients (p cite this article: Kanadani FN, Figueiredo CR, Miranda RM, Cunha PLT, Kanadani TCM, Dorairaj S. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients. J Curr Glaucoma Pract 2015;9(1):16-19.

  4. Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

    Science.gov (United States)

    Murray, P R

    1991-01-01

    Although the detection of fungemia has been improved by the use of vented or biphasic blood culture bottles, the best recovery and earliest detection have been reported in the Isolator lysis-centrifugation system. It was recently demonstrated that improved detection of both bacteria and fungi was accomplished by mechanically agitating blood culture bottles for the first 24 h of incubation. In this study the detection of fungemia by use of the Isolator system was compared with that of an agitated biphasic system. A total of 182 fungi were isolated from blood specimens inoculated into both culture systems. No difference in the overall recovery of fungi or individual species of yeasts was observed between the two systems. However, all seven isolates of Histoplasma capsulatum were recovered in the Isolator system only. The time required to detect fungemia with each of the two systems was also compared. No statistically significant difference was observed. From the data collected during this 18-month study, it can be concluded that the overall recovery and time of detection of yeasts are equivalent in the lysis-centrifugation system and the agitated biphasic blood culture system. The lysis-centrifugation system is still superior for the detection of filamentous fungi such as H. capsulatum. PMID:1993772

  5. Current and historical perspectives on methodological flaws in processing umbilical cord blood.

    Science.gov (United States)

    Mehrishi, J N

    2013-11-01

    Umbilical cord blood (UCB) hematopoietic stem cells (HSC-CD34+) are valuable for treating malignant or nonmalignant disease. Processing UCB by HESPAN-6% and anti-CD34-Miltenyi particles provides insufficient cells for treating adults. Physicochemical-electrokinetic studies on UCB-mononuclear cells (MNCs) under conditions of delayed processing, ice or very low temperatures, and some cell separation media identified artifacts introduced by procedures. Adsorption of biomaterials from cell damage by temperature, degradation products after using enzymes, harsh reagents, dithiothreitol, and HESPAN affect cell properties and distribution. Miltenyi particles internalized by cells could release iron that accumulating in liver or spleen would then risk toxicity. Summary topics included the effects of temperature, HESPAN (fast sedimenting agent), glycoproteases, DNase, and dithiothreitol risk affecting cell receptors in recognition, "homing," leading to possible unintended iatrogenic bioeffects should such cells be transfused into humans. The loss of undetectable and uncaptured low CD34 antigen-bearing cells by Miltenyi particles seems to occur when the current methods of isolation of CD34+ cells and other cells are critically assessed. The purpose here is to highlight and suggest avoiding the procedural flaws involved. Preventing ice temperatures avoids ice-damaged platelets releasing biomaterials that are adsorbed on cells altering UBC-MNCs/HSC properties and cell loss. Omitting the positive selection with antibody-linked Miltenyi particles obviates the use of harsh reagents to release the cells. Internalized Miltenyi particles are a toxicity hazard that needs investigations. Achieving approximately 5% yields of CD34+ cells (153 × 10(5) /110 mL cord-placenta blood) is a major advance holding great promise, for the first time increasing the prospect of stem cell therapy of 70-kg adults, using a single UCB donation (with dose of 1.5 × 10(5) cells/kg) and

  6. Dynamics of digestive proteolytic system during blood feeding of the hard tick Ixodes ricinus

    Directory of Open Access Journals (Sweden)

    Sojka Daniel

    2010-12-01

    Full Text Available Abstract Background Ticks are vectors of a wide variety of pathogens causing severe diseases in humans and domestic animals. Intestinal digestion of the host blood is an essential process of tick physiology and also a limiting factor for pathogen transmission since the tick gut represents the primary site for pathogen infection and proliferation. Using the model tick Ixodes ricinus, the European Lyme disease vector, we have previously demonstrated by genetic and biochemical analyses that host blood is degraded in the tick gut by a network of acidic peptidases of the aspartic and cysteine classes. Results This study reveals the digestive machinery of the I. ricinus during the course of blood-feeding on the host. The dynamic profiling of concentrations, activities and mRNA expressions of the major digestive enzymes demonstrates that the de novo synthesis of peptidases triggers the dramatic increase of the hemoglobinolytic activity along the feeding period. Overall hemoglobinolysis, as well as the activity of digestive peptidases are negligible at the early stage of feeding, but increase dramatically towards the end of the slow feeding period, reaching maxima in fully fed ticks. This finding contradicts the established opinion that blood digestion is reduced at the end of engorgement. Furthermore, we show that the digestive proteolysis is localized intracellularly throughout the whole duration of feeding. Conclusions Results suggest that the egressing proteolytic system in the early stage of feeding and digestion is a potential target for efficient impairment, most likely by blocking its components via antibodies present in the host blood. Therefore, digestive enzymes are promising candidates for development of novel 'anti-tick' vaccines capable of tick control and even transmission of tick-borne pathogens.

  7. [Design of blood-pressure parameter auto-acquisition circuit].

    Science.gov (United States)

    Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A

    2000-02-01

    This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.

  8. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  9. Health status of birds fed diets containing three differently processed discarded vegetable-bovine blood-rumen content mixtures.

    Science.gov (United States)

    Ekunseitan, D A; Balogun, O O; Sogunle, O M; Yusuf, A O; Ayoola, A A; Egbeyale, L T; Adeyemi, O A; Allison, I B; Iyanda, A I

    2013-04-01

    This study was conducted to determine the effect of feeding three differently processed mixtures on health status of broilers. A total of 1080 day-old Marshal broilers were fed; discarded vegetable-fresh bovine blood-fresh rumen digesta (P1), discarded vegetable-ensiled bovine blood-fresh rumen digesta (P2) and discarded vegetable-fresh bovine blood-ensiled rumen digesta (P3) at three levels of inclusion (0, 3 and 6%). Data on blood parameters was taken and were subjected to 3 x 3 factorial arrangements in a completely randomized design. Birds fed P1 had least values (p rumen digesta (P3) up to 6% level of inclusion.

  10. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    Science.gov (United States)

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (pair space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (ptransport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (ptransport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125 Section 864.9125 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  12. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    Science.gov (United States)

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  13. Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

    Science.gov (United States)

    Choi, Qute; Kim, Hyun Jin; Kim, Jong Wan; Kwon, Gye Cheol; Koo, Sun Hoe

    2018-01-04

    The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources. © 2018 Wiley Periodicals, Inc.

  14. Nitric oxide transport in blood: a third gas in the respiratory cycle.

    Science.gov (United States)

    Doctor, Allan; Stamler, Jonathan S

    2011-01-01

    The trapping, processing, and delivery of nitric oxide (NO) bioactivity by red blood cells (RBCs) have emerged as a conserved mechanism through which regional blood flow is linked to biochemical cues of perfusion sufficiency. We present here an expanded paradigm for the human respiratory cycle based on the coordinated transport of three gases: NO, O₂, and CO₂. By linking O₂ and NO flux, RBCs couple vessel caliber (and thus blood flow) to O₂ availability in the lung and to O₂ need in the periphery. The elements required for regulated O₂-based signal transduction via controlled NO processing within RBCs are presented herein, including S-nitrosothiol (SNO) synthesis by hemoglobin and O₂-regulated delivery of NO bioactivity (capture, activation, and delivery of NO groups at sites remote from NO synthesis by NO synthase). The role of NO transport in the respiratory cycle at molecular, microcirculatory, and system levels is reviewed. We elucidate the mechanism through which regulated NO transport in blood supports O₂ homeostasis, not only through adaptive regulation of regional systemic blood flow but also by optimizing ventilation-perfusion matching in the lung. Furthermore, we discuss the role of NO transport in the central control of breathing and in baroreceptor control of blood pressure, which subserve O₂ supply to tissue. Additionally, malfunctions of this transport and signaling system that are implicated in a wide array of human pathophysiologies are described. Understanding the (dys)function of NO processing in blood is a prerequisite for the development of novel therapies that target the vasoactive capacities of RBCs. © 2011 American Physiological Society.

  15. What's Blood?

    Science.gov (United States)

    ... Body Make Blood? It's not made in a kitchen, but blood has ingredients, just like a recipe. ... these ingredients together and you have blood — an essential part of the circulatory system. Thanks to your ...

  16. Non-association between anti-Toxoplasma gondii antibodies and ABO blood group system

    Directory of Open Access Journals (Sweden)

    ACF Rodrigues

    2011-01-01

    Full Text Available Toxoplasma gondii infects humans through the gastrointestinal tract (GIT, which elicits humoral immune response with specific antibodies. The expression of the ABO blood group glycoconjugates also occurs in this same system and may influence the human susceptibility of infection by T. gondii. The aim of the present study was to investigate the association between ABO blood group phenotypes and the presence of anti-T. gondii antibodies. Data - including age, results of serology tests for T. gondii infection and ABO blood group phenotypes - were assembled from the medical records of 1,006 pregnant women attended in the Base Hospital of the Medical School of São José do Rio Preto, Brazil, between 2001 and 2004. The chi-square test was used to compare the results with the level of significance set at 5%. Of the studied cases, 64.1% (645/1006 and 35.9% (391/1006 presented respectively positive and negative serology tests for anti-T. gondii antibodies. The mean age of those who tested positive was higher than those with negative serology tests (p = 0.0004. The frequencies of ABO blood group phenotypes were similar in those with and without anti-T. gondii antibodies (p = 0.35. In conclusion, the ABO blood group system is not associated with the presence or absence of anti-T. gondii antibodies.

  17. [Blood transfusion and supply chain management safety].

    Science.gov (United States)

    Quaranta, Jean-François; Caldani, Cyril; Cabaud, Jean-Jacques; Chavarin, Patricia; Rochette-Eribon, Sandrine

    2015-02-01

    The level of safety attained in blood transfusion now makes this a discipline better managed care activities. This was achieved both by scientific advances and policy decisions regulating and supervising the activity, as well as by the quality system, which we recall that affects the entire organizational structure, responsibilities, procedures, processes and resources in place to achieve quality management. So, an effective quality system provides a framework within which activities are established, performed in a quality-focused way and continuously monitored to improve outcomes. This system quality has to irrigate all the actors of the transfusion, just as much the establishments of blood transfusion than the health establishments. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Enrichment of reticulocytes from whole blood using aqueous multiphase systems of polymers.

    Science.gov (United States)

    Kumar, Ashok A; Lim, Caeul; Moreno, Yovany; Mace, Charles R; Syed, Abeer; Van Tyne, Daria; Wirth, Dyann F; Duraisingh, Manoj T; Whitesides, George M

    2015-01-01

    This paper demonstrates the enrichment of reticulocytes by centrifuging whole blood through aqueous multiphase systems (AMPSs)-immiscible phases of solutions of polymers that form step-gradients in density. The interfaces of an AMPS concentrate cells; this concentration facilitates the extraction of blood enriched for reticulocytes. AMPS enrich reticulocytes from blood from both healthy and hemochromatosis donors. Varying the osmolality and density of the phases of AMPS provides different levels of enrichment and yield of reticulocytes. A maximum enrichment of reticulocytemia of 64 ± 3% was obtained from donors with hemochromatosis. When used on peripheral blood from normal donors, AMPS can provide a higher yield of enriched reticulocytes and a higher proportion of reticulocytes expressing CD71 than differential centrifugation followed by centrifugation over Percoll. Blood enriched for reticulocytes by AMPS could be useful for research on malaria. Several species of malaria parasites show a preference to invade young erythrocytes and reticulocytes; this preference complicates in vitro cultivation of these species in human blood. Plasmodium knowlesi malaria parasites invade normal human blood enriched for reticulocytes by AMPSs at a rate 2.2 times greater (P blood. Parasite invasion in normal blood enriched by AMPS was 1.8 times greater (P blood enriched to a similar reticulocytemia by differential centrifugation followed by centrifugation over Percoll. The enrichment of reticulocytes that are invaded by malaria parasites demonstrates that AMPSs can provide a label-free method to enrich cells for biological research. © 2014 Wiley Periodicals, Inc.

  19. Blood Test: Testosterone

    Science.gov (United States)

    ... Test: Estradiol Precocious Puberty Understanding Puberty Endocrine System Male Reproductive System Getting a Blood Test (Video) All About Puberty Blood Test (Video) Male Reproductive System View more About Us Contact Us Partners Editorial ...

  20. The state of glutathion system of blood, brain and liver of white rats after chronic gamma-irradiation

    International Nuclear Information System (INIS)

    Petushok, N.Eh.; Lashak, L.K.; Trebukhina, R.V.

    1999-01-01

    The effects of 3-fold gamma-irradiation in total dose 0,75 Gy on the glutathion system in different periods after exposure (1 hour, 1 day, 1 and 4 weeks) in blood, brain and liver of white rats were studied. It was concluded that liver and brain have higher ability to maintain the stability of antioxidant system than blood has. After shot disturbances caused by irradiation in brain and liver the state of glutathion system of detoxication has normalized, while concentration of malonic dialdehyde was raised in all terms. The most pronounced changes of antioxidant system were registered in blood at early terms (1 hour) after irradiation that was manifested in increasing of reduced glutathion content, raising of glutathion reductase and catalase activity. In remote period the activity of this system in blood was exhausted

  1. White blood cell counting analysis of blood smear images using various segmentation strategies

    Science.gov (United States)

    Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza

    2017-09-01

    In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.

  2. Towards a Hyperconnected Transportation Management System: Application to Blood Logistics

    OpenAIRE

    Schoen , Quentin; Lauras , Matthieu; Truptil , Sébastien; Fontanili , Franck; Anquetil , Anne-Ghislaine

    2016-01-01

    Part 1: Hyperconnectivity and Interoperation - Hyperconnected Systems; International audience; Internet of Things, connected devices, and other wireless sensors networks offer a number of new opportunities to manage transportation flows. This is particularly interesting for critical Supply Chains like Blood Supply Chains. In this research work, we investigate how such new technologies can enhance transportation system by better managing hazards and changes. By developing an event-driven decis...

  3. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    Science.gov (United States)

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Regional blood flow studies with radioisotopes

    International Nuclear Information System (INIS)

    Holman, B.L.; McNiel, B.J.; Adelstein, S.J.

    1975-01-01

    The methodological approaches to blood flow analysis include (1) diffusible indicator methods, (2) clearance techniques and (3) nondiffusible indicator methods. In each case, accurate measurements of blood flow can be obtained by developing mathematical models which relate the time-dependent observation derived from following the fate of a radiotracer as a function of time to the physiological process itself. Application of these models to biological systems involves constraints and necessitates compromises which may affect the validity of the measurements. Nevertheless, when these techniques are carefully applied and adequately validated, they have provided critical physiological information about such organ systems as the brain and kidney and promise to provide diagnostic information in patients with suspected coronary and peripheral vascular disease

  5. The real world of blood glucose point-of-care testing (POCT) system running in China teaching hospital.

    Science.gov (United States)

    Li, Feng-Fei; Xie, Yun; Shi, Bing-Yin; Niu, Min; Guo, Hui; Cao, Yan; Liu, Bing-Li; Yan, Reng-Na; Su, Xiao-Fei; Wu, Jin-Dan; Zhang, Dan-Feng; Chen, Li-Ming; Ma, Jian-Hua

    2018-06-01

     The blood glucose point-of-care testing (POCT) system is important in the decision-making process involving patients suspected of having hypoglycemia. To investigate the real world of the POCT system being used in teaching hospitals in China. The survey was conducted by Hisend Research Group from May 2015 to July 2015 in four teaching hospitals in China. The survey questions were referred to the ISO 15197:2013 standard requirements for the use of the POCT system in a hospital setting. A total of 170 subjects were included from 4 hospitals, which included nursing staff, nurse unit managers, employees from the department of medical instruments, and staff members employed by the clinical laboratories in the Tianjin Metabolism Hospital, Nanjing First Hospital, First Affiliated Hospital of Dalian Medical University, and the First hospital affiliated with the Xi'an Transportation University. The average score for the four hospitals surveyed in this study was 66.6, which varied from 46.1 to 79.7. The main factors influencing the scores were the multiple choices of blood-glucose meters, and the quality control assessment. Our data indicates that the real world use of the POCT system in hospital settings in China needs more closer adherence to a quality management framework.

  6. Digital processing data communication systems (bus systems)

    International Nuclear Information System (INIS)

    Fleck, K.

    1980-01-01

    After an introduction to the technology of digital processing data communication systems there are the following chapters: digital communication of processing data in automation technology, the technology of biserial communication, the implementaiton of a bus system, the data transmission of the TDC-2000 system of Honeywell's and the process bus CS 275 in the automation system TELEPERM M of Siemens AG. (WB) [de

  7. Improving preanalytic processes using the principles of lean production (Toyota Production System).

    Science.gov (United States)

    Persoon, Thomas J; Zaleski, Sue; Frerichs, Janice

    2006-01-01

    The basic technologies used in preanalytic processes for chemistry tests have been mature for a long time, and improvements in preanalytic processes have lagged behind improvements in analytic and postanalytic processes. We describe our successful efforts to improve chemistry test turnaround time from a central laboratory by improving preanalytic processes, using existing resources and the principles of lean production. Our goal is to report 80% of chemistry tests in less than 1 hour and to no longer recognize a distinction between expedited and routine testing. We used principles of lean production (the Toyota Production System) to redesign preanalytic processes. The redesigned preanalytic process has fewer steps and uses 1-piece flow to move blood samples through the accessioning, centrifugation, and aliquoting processes. Median preanalytic processing time was reduced from 29 to 19 minutes, and the laboratory met the goal of reporting 80% of chemistry results in less than 1 hour for 11 consecutive months.

  8. Control system for technological processes in tritium processing plants with process analysis

    International Nuclear Information System (INIS)

    Retevoi, Carmen Maria; Stefan, Iuliana; Balteanu, Ovidiu; Stefan, Liviu; Bucur, Ciprian

    2005-01-01

    Integration of a large variety of installations and equipment into a unitary system for controlling the technological process in tritium processing nuclear facilities appears to be a rather complex approach particularly when experimental or new technologies are developed. Ensuring a high degree of versatility allowing easy modifications in configurations and process parameters is a major requirement imposed on experimental installations. The large amount of data which must be processed, stored and easily accessed for subsequent analyses imposes development of a large information network based on a highly integrated system containing the acquisition, control and technological process analysis data as well as data base system. On such a basis integrated systems of computation and control able to conduct the technological process could be developed as well protection systems for cases of failures or break down. The integrated system responds to the control and security requirements in case of emergency and of the technological processes specific to the industry that processes radioactive or toxic substances with severe consequences in case of technological failure as in the case of tritium processing nuclear plant. In order to lower the risk technological failure of these processes an integrated software, data base and process analysis system are developed, which, based on identification algorithm of the important parameters for protection and security systems, will display the process evolution trend. The system was checked on a existing plant that includes a removal tritium unit, finally used in a nuclear power plant, by simulating the failure events as well as the process. The system will also include a complete data base monitoring all the parameters and a process analysis software for the main modules of the tritium processing plant, namely, isotope separation, catalytic purification and cryogenic distillation

  9. Enhanced visuomotor processing of phobic images in blood-injury-injection fear.

    Science.gov (United States)

    Haberkamp, Anke; Schmidt, Thomas

    2014-04-01

    Numerous studies have identified attentional biases and processing enhancements for fear-relevant stimuli in individuals with specific phobias. However, this has not been conclusively shown in blood-injury-injection (BII) phobia, which has rarely been investigated even though it has features distinct from all other specific phobias. The present study aims to fill that gap and compares the time-course of visuomotor processing of phobic stimuli (i.e., pictures of small injuries) in BII-fearful (n=19) and non-anxious control participants (n=23) by using a response priming paradigm. In BII-fearful participants, phobic stimuli produced larger priming effects and lower response times compared to neutral stimuli, whereas non-anxious control participants showed no such differences. Because these effects are fully present in the fastest responses, they indicate an enhancement in early visuomotor processing of injury pictures in BII-fearful participants. These results are comparable to the enhanced processing of phobic stimuli in other specific phobias (i.e., spider phobia). Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Expert systems in process control systems

    International Nuclear Information System (INIS)

    Wittig, T.

    1987-01-01

    To illustrate where the fundamental difference between expert systems in classical diagnosis and in industrial control lie, the work of process control instrumentation is used as an example for the job of expert systems. Starting from the general process of problem-solving, two classes of expert systems can be defined accordingly. (orig.) [de

  11. [Immunologic risk analysis of blood transfusion: 1991-1998].

    Science.gov (United States)

    Rouger, P; Le Pennec, P Y; Noizat-Pirenne, F

    2000-02-01

    The immunologic risk associated to erythrocyte transfusions is bound to the polymorphism of blood group systems and to the respect of blood transfusion regulations. The results of three studies are presented, which were carried out respectively by the French Society of Blood Transfusion, the National Institute of Blood Transfusion and the National Haemovigilance Network. Two hundred and twenty-seven cases of immunologic accidents are analysed using the Kaplan's interpretation model and the traditional method of process analysis. The results show three critical factors in the occurrence of this type of incident: the relevance of the clinical examinations prescribed, the way in which the biological results are taken into account, and the relationship/exchange of information between private and public hospitals, and blood transfusion centers.

  12. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  13. Multicenter Clinical Evaluation of BacT/Alert Virtuo Blood Culture System.

    Science.gov (United States)

    Jacobs, Michael R; Mazzulli, Tony; Hazen, Kevin C; Good, Caryn E; Abdelhamed, Ayman M; Lo, Pauline; Shum, Bianche; Roman, Katharine P; Robinson, Danielle C

    2017-08-01

    BacT/Alert Virtuo is an advanced, automated blood culture system incorporating improved automation and an enhanced detection algorithm to shorten time to detection. A multicenter study of the investigational Virtuo system (bioMérieux, Inc., Durham, NC) compared to BacT/Alert 3D (BTA3D) for detection of bacteremia/fungemia in four bottle types, SA and FA Plus (aerobic) and SN and FN Plus (anaerobic), was performed in a clinical setting with patient samples in a matched system design clinical trial. Blood was added to paired aerobic or anaerobic bottles, with the volume in each bottle in each pair required to be ≤10 ml and with the volumes required to be within 30% of each other. Of 5,709 bottle sets (52.5% aerobic pairs and 47.5% anaerobic pairs), 430 (7.5%) were positive for bacterial or fungal growth, with 342 (6.0%) clinically significant and 83 (1.5%) contaminated. A total of 3,539 sets (62.0%) were volume compliant, with 203 sets (5.7%) clinically significant. The positivity rates for volume-compliant bottle pairs determined by the two systems were comparable, with 68.7% of clinically significant isolates detected by both instruments, 15.7% by Virtuo only, and 15.7% by BTA3D only. Virtuo detected microbial growth nearly 2 h sooner overall than BTA3D (mean, 15.9 h versus 17.7 h). Shorter time to detection by Virtuo was related to organism group, with the time to detection being significantly shorter for enteric Gram-negative bacilli and enterococci (means, 3.6 h and 2.3 h shorter, respectively). This large clinical study demonstrated that the Virtuo blood culture system produced results comparable to those seen with the long-established BTA3D system, with significantly shorter time to detection. Copyright © 2017 Jacobs et al.

  14. HB&L System: rapid determination of antibiotic sensitivity of bacteria isolated from blood cultures.

    Directory of Open Access Journals (Sweden)

    Simone Barocci

    2010-03-01

    Full Text Available Introduction. Blood culture is an important method to detect microbial pathogens on blood, very useful for diagnosing bacterial infections. Unfortunately, classical diagnostic protocols cannot directly identify bacteria responsible for sepsis and accordingly their antimicrobial profiles. This problem causes a delay of almost two days in the availability of a specific antimicrobial profile. Objective. Among the main causes of death, sepsis have a relevant importance. For this reason it is important both to identify pathogens and to perform an antimicrobial susceptibility test in the shortest time as possible. For this purpose, the main aim of this study is the evaluation of the performances of an antimicrobial susceptibility determination directly performed on positive blood cultures. Materials and methods. This study has been performed on 70 positive blood cultures, during the period from January to July 2009. A number of 35 blood cultures were positive for Gram negative bacteria, and 35 were positive for Gram positive bacteria. From these positive blood cultures, after a short sample preparation, it has been possible to directly determine antimicrobial susceptibility profiles by using the HB&L (formerly URO-QUICK instrument. Results. The HB&L system results showed a very good correlation with both the classical disk diffusion method and VITEK 2 automatic system.The performances between the methods carried out in this study were equivalent. Conclusions. From data reported, thanks to the rapidity and simplicity of the method used, we can assert that the direct susceptibility test available with the HB&L system, is useful for a rapid and early choice of the antibiotic treatment.

  15. Development of materials with blood compatibility by radiation processing

    International Nuclear Information System (INIS)

    Roesinger, S.; Fischer, J.P.; Fuhge, P.

    1982-01-01

    Biomedical applications, for example for rendering plastic materials blood compatible, have become a very important problem in recent years. Surface-grafted materials for blood compatibility have attracted attention for intra- and extracorporal applications. Numerous aspects of grafting monomers on to polymer surfaces by different grafting methods have been given. A large amount of work has been done during the last ten years, but nobody has prepared materials with properties that are desirable for long-term medical application in the human body, for example as replacements for small arteries or veins. The evaluation of blood compatibility of different plastic materials, and the search for correlations between blood compatibility and physical properties of the plastic materials surfaces, are well-known problems in the biomedical applications of polymers. This paper briefly reviews an approach to help solving these problems. (author)

  16. Rational Clinical Use of Blood and Blood products – A summary

    Directory of Open Access Journals (Sweden)

    D Ghartimagar

    2017-03-01

    Full Text Available Blood transfusion is an essential therapeutic intervention. The main role of the blood centre is to provide safe and timely blood and blood component(s to the patients that will improve the physiological status of the patient. Various blood components can be harvested from a single donation of whole blood. The blood centre ensures that there is an adequate inventory of all blood types and blood components to meet the needs of the patients. The blood centre does donor selection, blood collection, component preparation, screening for transfusion – transmitted infections and blood processing. Serologically compatible blood and components are provided to the patients after meticulous pre-transfusion testing as per the standard protocol. Rational use of blood and blood products means right product is used with the right dose on right time for the right reason.

  17. Microfluidic separation of viruses from blood cells based on intrinsic transport processes.

    Science.gov (United States)

    Zhao, Chao; Cheng, Xuanhong

    2011-09-01

    Clinical analysis of acute viral infection in blood requires the separation of viral particles from blood cells, since the cytoplasmic enzyme inhibits the subsequent viral detection. To facilitate this procedure in settings without access to a centrifuge, we present a microfluidic device to continuously purify bionanoparticles from cells based on their different intrinsic movements on the microscale. In this device, a biological sample is layered on top of a physiological buffer, and both fluids are transported horizontally at the same flow rate in a straight channel under laminar flow. While the micron sized particles such as cells sediment to the bottom layer with a predictable terminal velocity, the nanoparticles move vertically by diffusion. As their vertical travel distances have a different dependence on time, the micro- and nanoparticles can preferentially reside in the bottom and top layers respectively after certain residence time, yielding purified viruses. We first performed numerical analysis to predicate the particle separation and then tested the theory using suspensions of synthetic particles and biological samples. The experimental results using dilute synthetic particles closely matched the numerical analysis of a two layer flow system containing different sized particles. Similar purification was achieved using diluted blood spiked with human immunodeficiency virus. However, viral purification in whole blood is compromised due to extensive bioparticle collisions. With the parallelization and automation potential offered by microfluidics, this device has the potential to function as an upstream sample preparation module to continuously provide cell depleted bio-nanoparticles for downstream analysis.

  18. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  19. The Drosophila surface glia transcriptome: evolutionary conserved blood-brain barrier processes

    OpenAIRE

    DeSalvo, Michael K.; Hindle, Samantha J.; Rusan, Zeid M.; Orng, Souvinh; Eddison, Mark; Halliwill, Kyle; Bainton, Roland J.

    2014-01-01

    Central nervous system (CNS) function is dependent on the stringent regulation of metabolites, drugs, cells, and pathogens exposed to the CNS space. Cellular blood-brain barrier (BBB) structures are highly specific checkpoints governing entry and exit of all small molecules to and from the brain interstitial space, but the precise mechanisms that regulate the BBB are not well understood. In addition, the BBB has long been a challenging obstacle to the pharmacologic treatment of CNS diseases; ...

  20. Artificial heart system thermal converter and blood pump component research and development

    International Nuclear Information System (INIS)

    Pouchot, W.D.; Bifano, N.J.; Hanson, J.P.

    1975-01-01

    A bench model version of a nuclear-powered artificial heart system to be used as a replacement for the natural heart was constructed and tested as a part of a broader U. S. ERDA program. The objective of the broader program has been to develop a prototype of a fully implantable nuclear-powered total artificial heart system powered by the thermal energy of plutonium-238 and having minimum weight and volume and a minimum life of ten years. As a forward step in this broader program, component research and development has been carried out directed towards a fully implantable and advanced version of the bench model (IVBM). Some of the results of the component research and development effort on a Stirling engine, blood pump drive mechanisms, and coupling mechanisms are presented. The Stirling-mechanical system under development is shown. There are three major subassemblies: the thermal converter, the coupling mechanism, and the blood pump drive mechanism. The thermal converter uses a Stirling cycle to convert the heat of the plutonium-238 fueled heat source to a rotary shaft power output. The coupling mechanism changes the orientation of the output shaft by 90 degrees and transmits the pumping power by wire-wound core flexible shafting to the pumping mechanism. The coupling mechanism also provides routing of the coolant lines which carry the cycle waste heat from the thermal converter to the blood pump. The change in orientation of the thermal converter output shaft is for convenience in implanting in a calf. This orientation of thermal converter to blood pump seemed to give the best overall system fit in a calf based on fit trials with wooden models in a calf cadaver

  1. Experimental study of the use of refrigeration systems as cooling and heating systems in the production process of the VCO

    Science.gov (United States)

    Mulawarman, AANB; Arsana, M. E.; Temaja, I. W.; Sukadana, IBP

    2018-01-01

    Coconut oil extracted from the coconut milk obtained from fresh coconuts s often called virgin coconut oil (VCO). VCO is beneficial to health as an anti-oxidant and can lower HDL cholesterol in the blood while increasing blood LDL levels. In Indonesia most of VCO being produced on a small scale of home industries. Its production capacity still needs to be increased by improving production processes and implementing an appropriate technology accordingly. This research aims to conduct a study on making small-scale production machinery needed to produce VCO with reduced production time and improved quality of VCO in accordance with ISO 7381 quality criteria. The experimental results of the VCO machine has been develop and tested show good Coefficient of Performance of the system in amount of 3.93 and 2.8 for heating and cooling system respectively. Temperature of the VCO cooling chamber can be maintained in the range of 8°C to 10°C, as well as for heating, the reactor temperature can be maintained from 39°C to 42°C. The expected goal of this research developing a prototype of VCO production machine was done with ability to provide more efficient production process able to increase volume of VCO result by 23%.

  2. Periodontal disease level-butyric acid putatively contributes to the ageing blood: A proposed link between periodontal diseases and the ageing process.

    Science.gov (United States)

    Cueno, Marni E; Seki, Keisuke; Ochiai, Kuniyasu; Imai, Kenichi

    2017-03-01

    Periodontal diseases are partly attributable to periodontopathic bacteria found in the host, whereas, butyric acid (BA) is a common secondary metabolite produced by periodontopathic bacterial pathogens. BA has been linked to oxidative stress induction while oxidative stress has long been associated with the ageing process. However, the possible link between BA-induced oxidative stress and the ageing process has never been elucidated. Here, we attempted to show the possible role of periodontal diseaselevel-BA (PDL-BA) in influencing the rat blood ageing process. We injected PDL-BA into the young rat gingiva and, after 24h, heart blood extraction was performed. Blood obtained from PDL-BA-treated young rats was compared to untreated young and middle-aged rats. We found that cytosolic, but not mitochondrial, heme was affected 24h post-injection. In addition, we observed that PDL-BA treatment altered blood NOX activation, NADPH-related oxidative stress components (H 2 O 2 and GR), calcium homeostasis, cell death signals (CASP3 and CASP1), and age-related markers (SIRT1 and mTOR) in young rats, with some components more closely mimicking levels found in middle-aged rats. In this regard, we propose that PDL-BA may play a role in contributing to the rat blood ageing process. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Fibronectin changes in eosinophilic meningitis with blood-CSF barrier disruption.

    Science.gov (United States)

    Shyu, Ling-Yuh; Hu, Ming-E; Chou, Chun-Hui; Chen, Ke-Min; Chiu, Ping-Sung; Lai, Shih-Chan

    2015-01-01

    Fibronectin, which is present at relatively low levels in healthy central nervous systems (CNS), shows increased levels in meningitis. In this study, fibronectin processing was correlated with the increased permeability of the blood-cerebrospinal fluid (CSF) barrier as well as with the formation of eosinophil infiltrates in angiostrongyliasis meningitis. The immunohistochemistry results show matrix metalloproteinase-9 (MMP-9) is localized in the choroid plexus epithelium. Coimmunoprecipitation demonstrated fibronectin strongly binds MMP-9. Furthermore, treatment with the MMP-9 inhibitor GM6001 significantly inhibited fibronectin processing, reduced the blood-CSF barrier permeability, and decreased the eosinophil counts. The decreased fibronectin processing in CSF implies decreased cellular invasion of the subarachnoid space across the blood-CSF barrier. Therefore, increased fibronectin processing may be associated with barrier disruption and participate in the extravasation and migration of eosinophils into the CNS during experimental parasitic infection. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Changes in the nervous system state and peripheral blood parameters under benzene intoxication during an experiment

    Directory of Open Access Journals (Sweden)

    R.A. Orujov

    2017-12-01

    Full Text Available Benzene is a widely spread chemical health risk factor. Our research goal was to examine the nervous system state and the blood system state under benzene intoxication during an experiment. An acute experiment was performed on 45 white mice with 5-fold poisoning with benzene; a chronic one was performed on 72 rabbits being under inhalation exposure to benzene during 4 months, its concentrations increasing and fluctuating. We determined the following blood parameters: number of reticulocytes, eosinophils, basocytes, and erythrocytes; erythrocytes sedimentation rate; blood clotting period; blood clot retraction; plasma re-calcification period; plasma tolerance to heparin; prothrombin time; prothrombin index; fibrinogen concentration; blood fibrinolytic activity; acetylcholine and choline esterase contents. We also determined adrenalin, noradrenalin, dopamine, and dihydroxyphenylalanine contents in urine. Acute experiments results revealed that one-time exposure to benzene exerted a narcotic effect on the central nervous system which had an excitation phase and inhibition phase. Under a repeat exposure to benzene animals' drug intoxication was shorter. And here neutrophils / leucocytes gradient first increased to 139.5 % from its standards value and then when down under consequent intoxications. We detected relevant changes in morphological picture of animals' peripheral blood and their central and vegetative nervous system under chronic exposure to intermittent and increasing benzene concentrations. So, our research revealed that effects exerted by benzene in small concentrations led to apparent shifts in white blood and catecholamines (adrenalin, noradrenalin, dopamine, and dihydroxyphenylalanine. We also detected certain signs that cate-cholamines endogenous reserves (dihydroxyphenylalanine were depleted and, and also signs of eosinophils-basocytes disso-ciation; such prognostic signs were considered to be unfavorable as it was exactly at that

  5. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  6. DUAL-PROCESS, a highly reliable process control system

    International Nuclear Information System (INIS)

    Buerger, L.; Gossanyi, A.; Parkanyi, T.; Szabo, G.; Vegh, E.

    1983-02-01

    A multiprocessor process control system is described. During its development the reliability was the most important aspect because it is used in the computerized control of a 5 MW research reactor. DUAL-PROCESS is fully compatible with the earlier single processor control system PROCESS-24K. The paper deals in detail with the communication, synchronization, error detection and error recovery problems of the operating system. (author)

  7. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  8. Blood, donors and dollars: Rethinking financial sustainability of safe blood services in Tanzania

    Directory of Open Access Journals (Sweden)

    Kahabi Ganka Isangula

    2016-01-01

    Full Text Available Introduction Collection, processing and distribution of safe blood in Tanzania occurs within a free-for-service context, that is, a collection from non-remunerated blood donors and distributing freely to the needy people through health facilities. The safe blood services in the country appear to be crippled with many challenges and cannot meet the demand for blood and its products. As such, a need for rethinking collection methods, financial models and possible mechanisms for donor remuneration is evident. Methods In this paper, we venture on multi-stakeholder meetings and ongoing discussions regarding the internal mechanisms of safe blood transfusion financing. The intent is to offer a perspective on the considerations for self- sustaining safe blood services in the country and the extent to which they may be implemented or not. Results We suggest that despite huge demand, the external donor dependent financing mechanisms for safe blood services in the country are ineffective. Therefore, we discuss two potential ‘internal’ financing mechanisms that have been identified in recent shareholders forums 1 introducing a blood processing fee accompanied by policy change to allow direct charging of either recipients or hospitals or 2 influencing the introduction of ‘blood services’ within the current insurance schemes. Conclusion We conclude that there is a need for constructing alternative financial mechanisms to sustain the demand of safe blood in the country. We discuss two cost recovery mechanisms, blood processing fee and insurance schemes; however, warning is noted that their implementation warrants structural adjustments, massive community sensitization and optimum stakeholder engagement to maximize acceptability within the country.

  9. Coded ultrasound for blood flow estimation using subband processing

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Nielsen, Michael bachmann

    2007-01-01

    This paper further investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband...... coded signals are used to increase SNR, followed by sub-band processing. The received broadband signal, is filtered using a set of narrow-band filters. Estimating the velocity in each of the bands and averaging the results yields better performance compared to what would be possible when transmitting...... a narrow-band pulse directly. Also, the spatial resolution of the narrow-band pulse would be too poor for brightness-mode (B-mode) imaging and additional transmissions would be required to update the B-mode image. In the described approach, there is no need for additional transmissions, because...

  10. Effect of wine processing and acute blood stasis on the serum pharmacochemistry of rhubarb: a possible explanation for processing mechanism.

    Science.gov (United States)

    Wang, Min; Fu, Jinfeng; Lv, Mengying; Tian, Yuan; Xu, Fengguo; Song, Rui; Zhang, Zunjian

    2014-09-01

    As a specific item mentioned in traditional Chinese medicine theory, processing can fulfill different requirements of therapies. Crude and wine-processed rhubarbs are used as drastic and mild laxatives, respectively. In this study, a practical method based on ultra-fast liquid chromatography coupled with diode-array detection and ion trap time-of-flight mass spectrometry was developed to screen and analyze multiple absorbed bioactive components and metabolites in the serum of both normal and acute blood stasis rats after oral administration of crude or wine-processed rhubarbs. A total of 16 compounds, mainly including phase II metabolites, were tentatively identified. Possible explanations for the processing-induced changes in pharmacological effects of traditional Chinese medicines were first explored at serum pharmacochemistry level. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Nanoparticles and the blood coagulation system. Part I: benefits of nanotechnology.

    Science.gov (United States)

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2013-05-01

    Nanotechnology is proven to provide certain benefits in drug delivery by improving solubility, increasing uptake to target sites and changing pharmacokinetics profiles of traditional drugs. Since properties of many materials change tremendously at the nanoscale levels, nanotechnology is also being explored in various industrial applications. As such, nanoparticles are rapidly entering various areas of industry, biology and medicine. The benefits of using nanotechnology for industrial and biomedical applications are often tempered by concerns about the safety of these new materials. One such area of concern includes their effect on the immune system. While nanoparticle interactions with various constituents of the immune system have been reviewed before, little attention was given to nanoparticle effects on the blood coagulation system. Nanoparticle interface with the blood coagulation system may lead to either benefits to the host or adverse reactions. This article reviews recent advances in our understanding of nanoparticle interactions with plasma coagulation factors, platelets, endothelial cells and leukocytes. Part I is focused on desirable interactions between nanoparticles and the coagulation system, and discusses benefits of using nanotechnology to intervene in coagulation disorders. Undesirable interactions posing safety concerns are covered in part II, which will be published in the June issue of Nanomedicine.

  12. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  13. Central Gi(2) proteins, sympathetic nervous system and blood pressure regulation

    Czech Academy of Sciences Publication Activity Database

    Zicha, Josef

    2016-01-01

    Roč. 216, č. 3 (2016), s. 258-259 ISSN 1748-1708 Institutional support: RVO:67985823 Keywords : inhibitory G proteins * sympathetic nervous system * central blood pressure control Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 4.867, year: 2016

  14. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  15. [Measures to prevent patient identification errors in blood collection/physiological function testing utilizing a laboratory information system].

    Science.gov (United States)

    Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji

    2013-08-01

    We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.

  16. On cerebrae blood circulation from data of radiocirculography in some diseases of central nervous system in children

    International Nuclear Information System (INIS)

    Dolgov, A.G.; Stroganova, L.I.; Chirkin, N.I.

    1980-01-01

    Results of radioisotope investigation of cerebral blood circulation in 202 children with different pathology of central nervous system are presented. Velocity of cerebral blood flow and time of semiaccumulation and semimoving a preparate were investigated by means of sup(113m)In. It is established that radiocirculography shows clearly the changes in the system of cerebral blood supply and in such diseases as vegetovascular distonia and hypertension syndrome, the radiocirculography data pass ahead the clinical picture

  17. Effects of Topical Phenylephrine HCl 2.5% used before Cataract Surgery on Systemic Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emre Ayıntap

    2011-06-01

    Full Text Available Purpose: To evaluate the effect of topical phenylephrine HCl 2.5% (Mydfrin, used as a fast and effective mydriatic before cataract surgery, on systemic blood pressure. Material and Method: Topical phenylephrine HCl 2.5% was administered 3 times with 5-minute intervals before cataract surgery to 44 eyes of 44 patients. The systemic blood pressure was measured preoperatively and at 15 and 30 minutes. Results: The mean systolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 119.7mmHg, while 15 and 30 minutes later, it was 125.3 mmHg and 121.2 mmHg, respectively. The mean diastolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 75.9 mmHg; 15 and 30 minutes later, it was 76.9 mmHg and 75.3 mmHg, respectively. The increase in systolic blood pressure at 15 and 30 minutes was statistically significant (p=0.003 and p=0.042. The change in diastolic blood pressure was not statistically significant. Discussion: Phenylephrine HCl 2.5%, which is used preoperatively as a fast and effective mydriatic for cataract surgery, can increase the systolic blood pressure. This effect is most significant at 15 minutes and lasts at least 30 minutes. This agent should be used with care in hypertensive patients. (Turk J Ophthalmol 2011; 41: 164-6

  18. Printed microfluidic filter for heparinized blood.

    Science.gov (United States)

    Bilatto, Stanley E R; Adly, Nouran Y; Correa, Daniel S; Wolfrum, Bernhard; Offenhäusser, Andreas; Yakushenko, Alexey

    2017-05-01

    A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8  μ l) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.

  19. Systemic arterial hypertension, blood pressure levels and associated factors in schoolchildren

    Directory of Open Access Journals (Sweden)

    Priscila Heleno

    Full Text Available Summary Introduction: Hypertension is a major public health problem in contemporary times and it has high prevalence throughout the world. Objective: To investigate the situation of Systemic Arterial Hypertension in schoolchildren aged 6 to 10 years in Divinópolis/MG-Brazil and associated factors. Method: This is a cross-sectional, epidemiological, descriptive and analytical study, whose population was children aged 6 to 10 years enrolled in public schools in Divinópolis-MG-Brazil. Data collection was conducted from October 2014 to May 2015. Multivariate linear regressions were used to test associations between blood pressure, socioeconomic, anthropometric, dietary and physical activity. Results: The prevalence of hypertension was 15.2% in a sample of 284 children and mean values of systolic blood pressure of 101.7 (±13.2 mmHg and diastolic blood pressure of 66.0 (±11.2 mmHg. The body fat percentage showed significant differences between the genders, with 24.2 and 26.2%, respectively for boys and girls. Significant associations were made between blood pressure levels, body weight, body mass index, waist circumference, body fat percentage, consumption of yogurt, beef /chicken, beans, pizza, sandwich and some behaviors variables. Conclusion: The presented data show important aspects of school profile in the age range 6-10 years, especially related to the behavior of blood pressure.

  20. Transfusion management using a remote-controlled, automated blood storage.

    Science.gov (United States)

    Pagliaro, Pasqualepaolo; Turdo, Rosalia

    2008-04-01

    Generally, the safety of transfusion terapies for patients depends in part on the distribution of the blood products. The prevention of adverse events can be aided by technological means, which, besides improving the traceability of the process, make errors less likely. In this context, the latest frontier in automation and computerisation is the remote-controlled, automated refrigerator for blood storage. Computer cross-matching is an efficient and safe method for assigning blood components, based on Information Technology applied to typing and screening. This method can be extended to the management of an automated blood refrigerator, the programme of which is interfaced with the Transfusion Service's information system. The connection we made in our Service between EmoNet and Hemosafe enables real-time, remote-controlled management of the following aspects of blood component distribution: a) release of autologous and allogeneic units already allocated to a patient, b) release of available units, which can be allocated by remote-control to known patients, in the presence of a valid computer cross-match, c) release of O-negative units of blood for emergencies. Our system combines an information database, which enables computer cross-matching, with an automated refrigerator for blood storage with controlled access managed remotely by the Transfusion Service. The effectiveness and safety of the system were validated during the 4 months of its routine use in the Transfusion Service's outpatient department. The safety and efficiency of the distribution of blood products can and must be increased by the use of technological innovations. With the EmoNet/Hemosafe system, the responsibility for the remote-controlled distribution of red blood cell concentrates remains with the chief of the Transfusion Services, through the use of automated computer procedures and supported by continuous training of technicians and nursing staff.

  1. Current concepts in blood glucose monitoring.

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-12-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  2. Current concepts in blood glucose monitoring

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827

  3. Current concepts in blood glucose monitoring

    Directory of Open Access Journals (Sweden)

    Kranti Shreesh Khadilkar

    2013-01-01

    Full Text Available Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG and continuous glucose monitoring system (CGMS. It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  4. Safe transition to surgery: working differently to make blood transfusion process safer for elective surgery.

    Science.gov (United States)

    Badjie, Karafa S W; Rogers, James C; Jenkins, Sarah M; Bundy, Kevin L; Stubbs, James R; Cima, Robert R

    2015-09-01

    Our institutional policy allows patients who are scheduled for elective surgery with no history of a pregnancy or blood transfusion in the preceding 3 months to have a presurgical sample (PSS) collected and tested up to 56 days before their scheduled surgery; however, our PSS TS completion rate in eligible patients before the morning of surgery was 83%. In 2011, a team was charged to develop a standardized process along with other process improvements while ensuring no increase in transfusion-related events. The team followed the DMAIC framework in appraising the effectiveness and efficiency of the current state process including baseline data collection such as PSS TS completion rate, number of eligible patients needing a PSS TS on the day of surgery, benchmarking, SSBO utilization, and future state mapping. First quarter (Q1) 2011 versus Q1 2012 postimplementation results showed significant improvements of the process including a 53% decrease in PSS TS on the day of surgery; a 13% increase in PSS TS completion before the morning of surgery; a 26% reduction in total XM RBCs; and a 58.8% reduction in XM RBCs not issued, plus a 47% decrease in RBC wastage. Q1 2011 versus Q1 2013 showed a 41% reduction in total XM RBCs and an 88.4% reduction in XM RBCs not issued but overall RBCs issued versus returned increased slightly and represents a future opportunity for improvement. The redesigned, transformational process eliminated SSBO and improved ordering process and PSS TS completion rate as well as blood product ordering and utilization. © 2015 AABB.

  5. Activity-based costs of blood transfusions in surgical patients at four hospitals.

    Science.gov (United States)

    Shander, Aryeh; Hofmann, Axel; Ozawa, Sherri; Theusinger, Oliver M; Gombotz, Hans; Spahn, Donat R

    2010-04-01

    Blood utilization has long been suspected to consume more health care resources than previously reported. Incomplete accounting for blood costs has the potential to misdirect programmatic decision making by health care systems. Determining the cost of supplying patients with blood transfusions requires an in-depth examination of the complex array of activities surrounding the decision to transfuse. To accurately determine the cost of blood in a surgical population from a health system perspective, an activity-based costing (ABC) model was constructed. Tasks and resource consumption (materials, labor, third-party services, capital) related to blood administration were identified prospectively at two US and two European hospitals. Process frequency (i.e., usage) data were captured retrospectively from each hospital and used to populate the ABC model. All major process steps, staff, and consumables to provide red blood cell (RBC) transfusions to surgical patients, including usage frequencies, and direct and indirect overhead costs contributed to per-RBC-unit costs between $522 and $1183 (mean, $761 +/- $294). These exceed previously reported estimates and were 3.2- to 4.8-fold higher than blood product acquisition costs. Annual expenditures on blood and transfusion-related activities, limited to surgical patients, ranged from $1.62 to $6.03 million per hospital and were largely related to the transfusion rate. Applicable to various hospital practices, the ABC model confirms that blood costs have been underestimated and that they are geographically variable and identifies opportunities for cost containment. Studies to determine whether more stringent control of blood utilization improves health care utilization and quality, and further reduces costs, are warranted.

  6. Prenatal typing of Rh and Kell blood group system antigens: The edge of a watershed

    NARCIS (Netherlands)

    van der Schoot, C. Ellen; Tax, G. H. Martine; Rijnders, Robbert J. P.; de Haas, Masja; Christiaens, Godelieve C. M. L.

    2003-01-01

    Knowledge of the molecular basis of the blood group systems has enabled the development of assays for blood group genotyping. At this time, polymerase chain reaction (PCR)-based assays validated on fetal material obtained by invasive means (chorionic villus sampling or amniocentesis) are available

  7. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system.

    Science.gov (United States)

    Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F

    2011-01-01

    Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  8. Patient safety with blood products administration using wireless and bar-code technology.

    Science.gov (United States)

    Porcella, Aleta; Walker, Kristy

    2005-01-01

    Supported by a grant from the Agency for Healthcare Research and Quality, a University of Iowa Hospitals and Clinics interdisciplinary research team created an online data-capture-response tool utilizing wireless mobile devices and bar code technology to track and improve blood products administration process. The tool captures 1) sample collection, 2) sample arrival in the blood bank, 3) blood product dispense from blood bank, and 4) administration. At each step, the scanned patient wristband ID bar code is automatically compared to scanned identification barcode on requisition, sample, and/or product, and the system presents either a confirmation or an error message to the user. Following an eight-month, 5 unit, staged pilot, a 'big bang,' hospital-wide implementation occurred on February 7, 2005. Preliminary results from pilot data indicate that the new barcode process captures errors 3 to 10 times better than the old manual process.

  9. Tumor blood flow and systemic shunting in patients receiving intraarterial chemotherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Wheeler, R.H.; Ziessman, H.A.; Medvec, B.R.; Juni, J.E.; Thrall, J.H.; Keyes, J.W.; Pitt, S.R.; Baker, S.R.

    1986-01-01

    Radionuclide techniques have been used to estimate the systemic shunt and to quantitate blood flow to the tumor and a reference normal tissue in nine patients undergoing intraarterial chemotherapy for head and neck cancer. The systemic shunt was calculated as the percentage of pulmonary trapping of intraarterially injected /sup 99m/Tc-labeled macroaggregated albumin. The mean systemic shunt in the 12 separate arteries studied was 23 +/- 13% (SE) (range 8-43%). Quantitative blood flow was determined from the slope of the washout curve of intraarterially injected 133 Xe. The mean tumor blood flow was 13.6 +/- 6.7 ml/100 g/min, while the mean blood flow to the scalp was 4.2 +/- 2.1 ml/100 g/min providing a mean tumor/normal tissue ratio of 3.9 +/- 2.7. An estimate of blood flow distribution was obtained by calculating the ratio of counts/pixel in the tumor mass versus the remainder of the head as determined by single photon emission computed tomography following an intraarterial injection of /sup 99m/Tc-labeled macroaggregated albumin. The mean ratio of tumor to normal tissue perfusion by this technique was 5.6 +/- 3.7. These techniques have allowed noninvasive determination of the blood flow parameters associated with intraarterial chemotherapy. At least part of the therapeutic advantage of regional chemotherapy in patients with head and neck cancer is due to a tumor/normal tissue blood flow ratio that favors drug delivery to the tumor contained within the infused volume

  10. Alpha-Amylase Activity in Blood Increases after Pharmacological, But Not Psychological, Activation of the Adrenergic System.

    Directory of Open Access Journals (Sweden)

    Urs M Nater

    Full Text Available Alpha-amylase in both blood and saliva has been used as a diagnostic parameter. While studies examining alpha-amylase activity in saliva have shown that it is sensitive to physiological and psychological challenge of the adrenergic system, no challenge studies have attempted to elucidate the role of the adrenergic system in alpha-amylase activity in blood. We set out to examine the impact of psychological and pharmacological challenge on alpha-amylase in blood in two separate studies.In study 1, healthy subjects were examined in a placebo-controlled, double-blind paradigm using yohimbine, an alpha2-adrenergic antagonist. In study 2, subjects were examined in a standardized rest-controlled psychosocial stress protocol. Alpha-amylase activity in blood was repeatedly measured in both studies.Results of study 1 showed that alpha-amylase in blood is subject to stronger increases after injection of yohimbine compared to placebo. In study 2, results showed that there was no significant effect of psychological stress compared to rest.Alpha-amylase in blood increases after pharmacological activation of the adrenergic pathways suggesting that sympathetic receptors are responsible for these changes. Psychological stress, however, does not seem to have an impact on alpha-amylase in blood. Our findings provide insight into the mechanisms underlying activity changes in alpha-amylase in blood in healthy individuals.

  11. Optimization of sugar and blood feeding regimen in Anopheles gambiae mass production system

    International Nuclear Information System (INIS)

    Sedofia, B. K

    2013-07-01

    The sterile insect technique (SIT) is being developed for the control of malaria transmitting mosquitoes. Critical to the success of applying the SIT is the establishment of standardized mass production systems for the target species. As part of efforts to develop standardised mass production systems for malaria vectors, this project sought to optimize adult blood and sugar feeding in a mass production system. Different sugar types (glucose, sucrose and honey) were evaluated at 6% and 10% concentrations in water to determine the best sugar diet and concentration for feeding adult An. gambiae. Different blood feeding methods, restrained Guinea pig, anaesthetised Guinea pig and human arm feeding were evaluated. Adult survival, female insemination and egg production were used as criteria to determine optimum sugar and blood feeding. The effect of anaesthetics on blood feeding response and egg production of female An. gambiae was determined by comparing feeding response and egg production of females fed with anaesthetised Guinea pigs as against physically restrained Guinea pigs (Control). The specific effect of different anaesthetic agents on blood feeding response and egg production of female mosquitoes were was also determined by comparing the feeding response and egg production of females fed with either Ketamine/Xylazine anaesthetised Guinea pigs or Ketamine/Diazepam anaesthetised Guinea pigs. Effects due to sugar types and concentrations on percentage survival of male and female mosquitoes were observed to be significant at (p 0.05). However, human ann feeding (HAP) method and Ketamine/Xylazine (KX) anaesthetics fed for 25 minutes recorded higher percentage feeding (76.0% and 68.0% respectively) and egg production of 19.0% and 20.8% respectively. Anaesthetised Guinea pig feeding (AGF) of adults for 15 minutes followed closely with 60.0% and 15.1% blood feeding and egg production respectively whilst restrained Guinea pig feeding (RGF) method and Ketamine

  12. Current concepts in blood glucose monitoring

    OpenAIRE

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on t...

  13. Mathematical models of non-linear phenomena, processes and systems: from molecular scale to planetary atmosphere

    CERN Document Server

    2013-01-01

    This book consists of twenty seven chapters, which can be divided into three large categories: articles with the focus on the mathematical treatment of non-linear problems, including the methodologies, algorithms and properties of analytical and numerical solutions to particular non-linear problems; theoretical and computational studies dedicated to the physics and chemistry of non-linear micro-and nano-scale systems, including molecular clusters, nano-particles and nano-composites; and, papers focused on non-linear processes in medico-biological systems, including mathematical models of ferments, amino acids, blood fluids and polynucleic chains.

  14. Increased occupational coal dust toxicity in blood of central heating system workers.

    Science.gov (United States)

    Tuluce, Yasin; Ozkol, Halil; Koyuncu, Ismail; Ine, Hatice

    2011-02-01

    Coal dust causes lung diseases in occupational exposure. Reactive oxygen species have been implicated in the pathogenesis of its toxicity. In this study, serum enzymes, lipid profile and other biochemical values with oxidant/antioxidant status in whole blood and serum of central heating system workers (CHSW; the persons responsible for heating the apartment with coal) were determined to reflect the cell injury. Blood samples were obtained from CHSW (n = 25) and healthy individuals (n = 25). All values were measured in whole blood and serum. ANOVA was used for the estimation of statistical data. In the group of CHSW, creatinine, ferritin, alanin aminotransferase, aspartate aminotransferase, creatine phosphokinase, gamma glutamyl transferase, lactate dehydrogenase and glutathione reductase activities as well as triglyceride, very low density lipoprotein, protein carbonyl and malondialdehide were significantly higher, while transferrin, high density lipoprotein and catalase (CAT) activities were lower than the group of healthy individuals. This result is consistent with hypothesis that respirable coal dust generates lipid and protein oxidation and induces leakage of serum enzymes by cell damage. It also leads to imbalance in antioxidant defense system, lipid profile and other biochemical parameters.

  15. An experimental system for the study of ultrasound exposure of isolated blood vessels

    NARCIS (Netherlands)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and

  16. Evaluation of the BioFire® FilmArray® Blood Culture Identification Panel on positive blood cultures in a regional hospital laboratory in KwaZulu-Natal

    Directory of Open Access Journals (Sweden)

    Mokshanand Fhooblall

    2016-09-01

    Full Text Available Background: There are presently many non-culture-based methods commercially available to identify organisms and antimicrobial susceptibility from blood culture bottles. Each platform has its benefits and limitations. However, there is a need for an improved system with minimal hands-on requirements and short run times. Objectives: In this study, the performance characteristics of the FilmArray® BCID Panel kit were evaluated to assess the efficiency of the kit against an existing system used for identification and antimicrobial susceptibility of organisms from blood cultures. Methods: Positive blood cultures that had initially been received from hospitalised patients of a large quaternary referral hospital in Durban, South Africa were processed as per routine protocol at its Medical Microbiology Laboratory. Positive blood cultures were processed on the FilmArray BCID Panel kit in parallel with the routine sample processing. Inferences were then drawn from results obtained. Results: Organism detection by the FilmArray BCID panel was accurate at 92.6% when organisms that were on the repertoire of the kit were considered, compared to the combination methods (reference method used in the study laboratory. Detection of the antimicrobial resistance markers provided by the panel and reference method demonstrated 100% consistency. Blood cultures with a single organism were accurately identified at 93.8% by FilmArray, while blood cultures with more than one organism were identified at 85.7%. Conclusion: The FilmArray BCID Panel kit is valuable for detection of organisms and markers of antibiotic resistance for an extensive range of organisms.

  17. Appropriate Handling, Processing and Analysis of Blood Samples Is Essential to Avoid Oxidation of Vitamin C to Dehydroascorbic Acid.

    Science.gov (United States)

    Pullar, Juliet M; Bayer, Simone; Carr, Anitra C

    2018-02-11

    Vitamin C (ascorbate) is the major water-soluble antioxidant in plasma and its oxidation to dehydroascorbic acid (DHA) has been proposed as a marker of oxidative stress in vivo. However, controversy exists in the literature around the amount of DHA detected in blood samples collected from various patient cohorts. In this study, we report on DHA concentrations in a selection of different clinical cohorts (diabetes, pneumonia, cancer, and critically ill). All clinical samples were collected into EDTA anticoagulant tubes and processed at 4 °C prior to storage at -80 °C for subsequent analysis by HPLC with electrochemical detection. We also investigated the effects of different handling and processing conditions on short-term and long-term ascorbate and DHA stability in vitro and in whole blood and plasma samples. These conditions included metal chelation, anticoagulants (EDTA and heparin), and processing temperatures (ice, 4 °C and room temperature). Analysis of our clinical cohorts indicated very low to negligible DHA concentrations. Samples exhibiting haemolysis contained significantly higher concentrations of DHA. Metal chelation inhibited oxidation of vitamin C in vitro, confirming the involvement of contaminating metal ions. Although EDTA is an effective metal chelator, complexes with transition metal ions are still redox active, thus its use as an anticoagulant can facilitate metal ion-dependent oxidation of vitamin C in whole blood and plasma. Handling and processing blood samples on ice (or at 4 °C) delayed oxidation of vitamin C by a number of hours. A review of the literature regarding DHA concentrations in clinical cohorts highlighted the fact that studies using colourimetric or fluorometric assays reported significantly higher concentrations of DHA compared to those using HPLC with electrochemical detection. In conclusion, careful handling and processing of samples, combined with appropriate analysis, is crucial for accurate determination of ascorbate

  18. Blood Transfusion (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Transfusions KidsHealth / For Parents / Blood Transfusions What's in this ... and help put your child at ease. About Blood Transfusions Blood is like the body's transportation system. As ...

  19. IDAPS (Image Data Automated Processing System) System Description

    Science.gov (United States)

    1988-06-24

    This document describes the physical configuration and components used in the image processing system referred to as IDAPS (Image Data Automated ... Processing System). This system was developed by the Environmental Research Institute of Michigan (ERIM) for Eglin Air Force Base. The system is designed

  20. Assessment of a continuous blood gas monitoring system in animals during circulatory stress

    Directory of Open Access Journals (Sweden)

    Renzulli Attilio

    2011-01-01

    Full Text Available Abstract Background The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min, vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h, hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia, and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg.Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed. Results Bias and precision for pO2 were - 0.06 kPa and 0.22 kPa, respectively (r2 = 0.96; pCO2 - 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r2 = 0.96. The analysis showed very good agreement for SO2 (bias 0.04,precision 0.33, r2 = 0.95, Base excess (bias 0.04,precision 0.28, r2 = 0.98, HCO3 (bias 0.05,precision 0.62, r2 = 0.92,hemoglobin (bias 0.02,precision 0.23, r2 = 0.96 and K+ (bias 0.02, precision 0.27, r2 = 0.93. The sensor was reliable throughout the experiment during hemodynamic variations. Conclusions Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.

  1. Proposed Application of Fast Fourier Transform in Near Infra Red Based Non Invasive Blood Glucose Monitoring System

    Science.gov (United States)

    Jenie, R. P.; Iskandar, J.; Kurniawan, A.; Rustami, E.; Syafutra, H.; Nurdin, N. M.; Handoyo, T.; Prabowo, J.; Febryarto, R.; Rahayu, M. S. K.; Damayanthi, E.; Rimbawan; Sukandar, D.; Suryana, Y.; Irzaman; Alatas, H.

    2017-03-01

    Worldwide emergence of glycaemic status related health disorders, such as diabetes and metabolic syndrome, is growing in alarming rate. The objective was to propose new methods for non invasive blood glucose level measurement system, based on implementation of Fast Fourier Transform methods. This was an initial-lab-scale-research. Data on non invasive blood glucose measurement are referred from Scopus, Medline, and Google Scholar, from 2011 until 2016, and was used as design references, combined with in house verification. System was developed in modular fashion, based on aforementioned compiled references. Several preliminary tests to understand relationship between LED and photo-diode responses have been done. Several references were used as non invasive blood glucose measurement tools design basis. Solution is developed in modular fashion. we have proven different sensor responses to water and glucose. Human test for non invasive blood glucose level measurement system is needed.

  2. Tainted blood

    DEFF Research Database (Denmark)

    Deleuran, Ida; Sheikh, Zainab Afshan; Hoeyer, Klaus

    2015-01-01

    The existing literature on donor screening in transfusion medicine tends to distinguish between social concerns about discrimination and medical concerns about safety. In this article, we argue that the bifurcation into social and medical concerns is problematic. We build our case on a qualitative...... study of the historical rise and current workings of safety practices in the Danish blood system. Here, we identify a strong focus on contamination in order to avoid 'tainted blood', at the expense of working with risks that could be avoided through enhanced blood monitoring practices. Of further...... significance to this focus are the social dynamics found at the heart of safety practices aimed at avoiding contamination. We argue that such dynamics need more attention, in order to achieve good health outcomes in transfusion medicine. Thus, we conclude that, to ensure continuously safe blood systems, we...

  3. Some central nervous system and blood pressure lowering effects of ...

    African Journals Online (AJOL)

    The methanol extract of the leaves of Spondias mombin (SP) was evaluated for some central nervous system and blood pressure lowering effect in albino wistar rats and mice. The extract was administered to pre-weighed mice (20-35 g), divided into five groups of five mice each at the doses of 50, 100 and 200 mg/kg for the ...

  4. Noninvasive biosensor and wireless interrogating system for glucose in blood

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.

    2003-07-01

    Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.

  5. Evaluation of the overnight hold of whole blood at room temperature, before component processing: platelets (PLTs) from PLT-rich plasma.

    Science.gov (United States)

    van der Meer, Pieter F; Cancelas, Jose A; Vassallo, Ralph R; Rugg, Neeta; Einarson, Mindy; Hess, John R

    2011-01-01

    Whole blood (WB) must be refrigerated within 8 hours to optimize Factor VIII: C yield, but chilled platelets (PLTs) are rapidly removed from circulation and cannot be used clinically. It is logistically preferable to hold WB overnight at room temperature for next-day processing. We compared in vitro quality of PLT-rich plasma (PRP)-derived PLT concentrates (PCs) from fresh versus overnight-held WB. Four units of WB were pooled and split to prevent donor-dependent differences. One unit was processed immediately; three others were held at room temperature and processed after 24 to 26 hours. After soft-spin centrifugation, PRP was separated from the red blood cells. PRP was hard-spun to make PLT-poor plasma, and the PLTs were resuspended in approximately 60 mL of plasma and stored for 7 days (n = 8 paired experiments by two blood centers). After overnight hold, the PLT concentration was 1.37 × 10(9) ± 0.19 × 10(9) /mL versus 1.03 × 10(9) ± 0.32 × 10(9) /mL for freshly prepared PCs (p < 0.05). pH and glucose were significantly lower and lactate higher for overnight-held units on Day 1, but by Day 5, the differences had disappeared. Hypotonic shock response was initially better, 73 ± 14% for overnight-held versus 53 ± 12% for freshly processed (p < 0.001), but this difference also disappeared during storage. Activation marker CD62P was not different. In vitro storage conditions produce immediate differences after preparation, which disappear throughout storage. PCs from overnight-held WB have similar in vitro variables as from freshly processed WB. These findings warrant confirmation in clinical trials, but underscore the possibility of use of these PCs as being equivalent to those obtained from freshly processed WB. © 2010 American Association of Blood Banks.

  6. Peptide-Mediated Liposomal Drug Delivery System Targeting Tumor Blood Vessels in Anticancer Therapy

    Directory of Open Access Journals (Sweden)

    Han-Chung Wu

    2010-01-01

    Full Text Available Solid tumors are known to recruit new blood vessels to support their growth. Therefore, unique molecules expressed on tumor endothelial cells can function as targets for the antiangiogenic therapy of cancer. Current efforts are focusing on developing therapeutic agents capable of specifically targeting cancer cells and tumor-associated microenvironments including tumor blood vessels. These therapies hold the promise of high efficacy and low toxicity. One recognized strategy for improving the therapeutic effectiveness of conventional chemotherapeutics is to encapsulate anticancer drugs into targeting liposomes that bind to the cell surface receptors expressed on tumor-associated endothelial cells. These anti-angiogenic drug delivery systems could be used to target both tumor blood vessels as well as the tumor cells, themselves. This article reviews the mechanisms and advantages of various present and potential methods using peptide-conjugated liposomes to specifically destroy tumor blood vessels in anticancer therapy.

  7. Increasing blood flow to exercising muscle attenuates systemic cardiovascular responses during dynamic exercise in humans.

    Science.gov (United States)

    Ichinose, Masashi; Ichinose-Kuwahara, Tomoko; Kondo, Narihiko; Nishiyasu, Takeshi

    2015-11-15

    Reducing blood flow to working muscles during dynamic exercise causes metabolites to accumulate within the active muscles and evokes systemic pressor responses. Whether a similar cardiovascular response is elicited with normal blood flow to exercising muscles during dynamic exercise remains unknown, however. To address that issue, we tested whether cardiovascular responses are affected by increases in blood flow to active muscles. Thirteen healthy subjects performed dynamic plantarflexion exercise for 12 min at 20%, 40%, and 60% of peak workload (EX20, EX40, and EX60) with their lower thigh enclosed in a negative pressure box. Under control conditions, the box pressure was the same as the ambient air pressure. Under negative pressure conditions, beginning 3 min after the start of the exercise, the box pressure was decreased by 20, 45, and then 70 mmHg in stepwise fashion with 3-min step durations. During EX20, the negative pressure had no effect on blood flow or the cardiovascular responses measured. However, application of negative pressure increased blood flow to the exercising leg during EX40 and EX60. This increase in blood flow had no significant effect on systemic cardiovascular responses during EX40, but it markedly attenuated the pressor responses otherwise seen during EX60. These results demonstrate that during mild exercise, normal blood flow to exercising muscle is not a factor eliciting cardiovascular responses, whereas it elicits an important pressor effect during moderate exercise. This suggests blood flow to exercising muscle is a major determinant of cardiovascular responses during dynamic exercise at higher than moderate intensity. Copyright © 2015 the American Physiological Society.

  8. Advantages and Challenges of Dried Blood Spot Analysis by Mass Spectrometry Across the Total Testing Process

    Science.gov (United States)

    Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter

    2016-01-01

    Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263

  9. Effect of diet composition and mixture of selected food additives on the erythrocytic system and iron metabolism in peripheral blood of male rats.

    Science.gov (United States)

    Sadowska, Joanna; Kuchlewska, Magdalena

    2011-01-01

    Metabolic processes of food additives which are "exogenous xenobiotics" are catalysed, primarily, by enzymes located in microsomes of hepatocytes affiliated to P-450 cytochrome superfamily, containing iron. The aim of the study was to investigate the effect of diet composition and selected food additives on the erythrocyte system and iron metabolism in peripheral blood of male rats. The experiment was carried out on 30 male rats sorted into three equinumerous groups. For drinking animals received pure, settled tap water, animals from group III were receiving additionally an aqueous solution of sodium (nitrate), potassium nitrite, benzoic acid, sorbic acid and monosodium glutamate. Ascertained a significant effect of changes in diet composition on the increase in hematocrit marker value and the count of red blood cells in blood of animals examined. Used food additives diminished hemoglobin concentration, hematocrit value and red blood cell count, diminishing also iron concentration in serum, the total iron binding capacity and transferrin saturation with iron. Analysis of the results allowed ascertain adverse changes in values of the erythrocytic system markers, occurring under the influence of the applied mixture of food additives. Used food additives change the iron metabolism, most likely from the necessity of applied xenobiotics biotransformation by heme-containing monoxygenases of P-450 cytochrome.

  10. NHS Blood Tracking Pilot: City University Evaluation Project

    Science.gov (United States)

    Goddard, Kate; Shabestari, Omid; Adriano, Juan; Kay, Jonathan; Roudsari, Abdul

    Automation of healthcare processes is an emergent theme in the drive to increase patient safety. The Mayday Hospital has been chosen as the pilot site for the implementation of the Electronic Clinical Transfusion Management System to track blood from the point of ordering to the final transfusion. The Centre for Health Informatics at City University is carrying out an independent evaluation of the system implementation using a variety of methodologies to both formatively inform the implementation process and summatively provide an account of the lessons learned for future implementations.

  11. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system

    Directory of Open Access Journals (Sweden)

    N S Ozen

    2011-01-01

    Full Text Available Purpose: Differentiation of Staphylococcus aureus (S. aureus from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT, slide agglutination test (Dry Spot Staphytect Plus, conventional polymerase chain reaction (PCR and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. Materials and Methods: A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. Results: The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Conclusion: Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  12. Natural Information Processing Systems

    OpenAIRE

    John Sweller; Susan Sweller

    2006-01-01

    Natural information processing systems such as biological evolution and human cognition organize information used to govern the activities of natural entities. When dealing with biologically secondary information, these systems can be specified by five common principles that we propose underlie natural information processing systems. The principles equate: (1) human long-term memory with a genome; (2) learning from other humans with biological reproduction; (3) problem solving through random ...

  13. Accurate costs of blood transfusion: a microcosting of administering blood products in the United Kingdom National Health Service.

    Science.gov (United States)

    Stokes, Elizabeth A; Wordsworth, Sarah; Staves, Julie; Mundy, Nicola; Skelly, Jane; Radford, Kelly; Stanworth, Simon J

    2018-04-01

    In an environment of limited health care resources, it is crucial for health care systems which provide blood transfusion to have accurate and comprehensive information on the costs of transfusion, incorporating not only the costs of blood products, but also their administration. Unfortunately, in many countries accurate costs for administering blood are not available. Our study aimed to generate comprehensive estimates of the costs of administering transfusions for the UK National Health Service. A detailed microcosting study was used to cost two key inputs into transfusion: transfusion laboratory and nursing inputs. For each input, data collection forms were developed to capture staff time, equipment, and consumables associated with each step in the transfusion process. Costing results were combined with costs of blood product wastage to calculate the cost per unit transfused, separately for different blood products. Data were collected in 2014/15 British pounds and converted to US dollars. A total of 438 data collection forms were completed by 74 staff. The cost of administering blood was $71 (£49) per unit for red blood cells, $84 (£58) for platelets, $55 (£38) for fresh-frozen plasma, and $72 (£49) for cryoprecipitate. Blood administration costs add substantially to the costs of the blood products themselves. These are frequently incurred costs; applying estimates to the blood components supplied to UK hospitals in 2015, the annual cost of blood administration, excluding blood products, exceeds $175 (£120) million. These results provide more accurate estimates of the total costs of transfusion than those previously available. © 2018 AABB.

  14. A SYSTEM AND A DEVICE FOR ISOLATING CIRCULATING TUMOR CELLS FROM THE PERIPHERAL BLOOD IN VIVO

    Directory of Open Access Journals (Sweden)

    Michal Mego

    2015-08-01

    Full Text Available Circulating tumor cells (CTC play a crucial role in disseminating tumors and in the metastatic cascade. CTCs are found only in small numbers, and the limited amount of isolated CTCs makes it impossible to characterize them closely. This paper presents a proposal for a new system for isolating CTCs from the peripheral blood in vivo. The system enables CTCs to be isolated from the whole blood volume for further research and applications. The proposed system consists of magnetic nanoparticles covered by monoclonal antibodies against a common epithelial antigen, large supermagnets, which are used to control the position of the nanoparticles within the human body, and a special wire made of a magnetic core wrapped in a non-magnetic shell. The system could be used not only for isolating CTCs, but also for in vivo isolation of other rare cells from the peripheral blood, including hematopoietic and/or mesenchymal stem cells, with applications in regenerative medicine and/or in stem cell transplantation.

  15. Dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  16. Numerical simulations of a reduced model for blood coagulation

    Science.gov (United States)

    Pavlova, Jevgenija; Fasano, Antonio; Sequeira, Adélia

    2016-04-01

    In this work, the three-dimensional numerical resolution of a complex mathematical model for the blood coagulation process is presented. The model was illustrated in Fasano et al. (Clin Hemorheol Microcirc 51:1-14, 2012), Pavlova et al. (Theor Biol 380:367-379, 2015). It incorporates the action of the biochemical and cellular components of blood as well as the effects of the flow. The model is characterized by a reduction in the biochemical network and considers the impact of the blood slip at the vessel wall. Numerical results showing the capacity of the model to predict different perturbations in the hemostatic system are discussed.

  17. Processors and systems (picture processing)

    Energy Technology Data Exchange (ETDEWEB)

    Gemmar, P

    1983-01-01

    Automatic picture processing requires high performance computers and high transmission capacities in the processor units. The author examines the possibilities of operating processors in parallel in order to accelerate the processing of pictures. He therefore discusses a number of available processors and systems for picture processing and illustrates their capacities for special types of picture processing. He stresses the fact that the amount of storage required for picture processing is exceptionally high. The author concludes that it is as yet difficult to decide whether very large groups of simple processors or highly complex multiprocessor systems will provide the best solution. Both methods will be aided by the development of VLSI. New solutions have already been offered (systolic arrays and 3-d processing structures) but they also are subject to losses caused by inherently parallel algorithms. Greater efforts must be made to produce suitable software for multiprocessor systems. Some possibilities for future picture processing systems are discussed. 33 references.

  18. Application of mobile blood purification system in the treatment of acute renal failure dog model in the field environment

    Directory of Open Access Journals (Sweden)

    Zhi-min ZHANG

    2014-01-01

    Full Text Available Objective To evaluate the stability, safety and efficacy of mobile blood purification system in the treatment of acute renal failure dog model in the field environment. Methods The acute renal failure model was established in 4 dogs by bilateral nephrectomy, which was thereafter treated with the mobile blood purification system. The evaluation of functional index of the mobile blood purification system was performed after a short-time (2 hours and conventional (4 hours dialysis treatment. Results The mobile blood purification system ran stably in the field environment at a blood flow of 150-180ml/min, a dialysate velocity of 2000ml/h, a replacement fluid velocity of 2000ml/h, and ultrafiltration rate of 100-200ml/h. All the functions of alarming system worked well, including static upper limit alarm of ultrafiltration pressure (>100 mmHg, upper limit alarm of ambulatory arterial pressure (>400mmHg, upper limit alarm of ambulatory venous pressure (>400mmHg, bubble alarm of vascular access, bubble alarm during the infusion of solutions, pressure alarm at the substitution pump segment and blood leaking alarm. The vital signs of the 4 dogs with acute renal failure kept stable during the treatment. After the treatment, a remarkable decrease was seen in the levels of serum urea nitrogen, creatinine and serum potassium (P0.05. Conclusions The mobile blood purification system runs normally even in a field environment. It is a flexible and portable device with a great performance in safety and stability in the treatment of acute renal failure. DOI: 10.11855/j.issn.0577-7402.2013.12.15

  19. Symptoms of Blood Disorders

    Science.gov (United States)

    ... or immune system proteins can cause increased blood viscosity (thickening of the blood). Increased platelets or blood ... by anemia Pica (eating of ice, dirt, or clay) suggests iron deficiency anemia Drugs Mentioned In This ...

  20. Fresenius AS.TEC204 blood cell separator.

    Science.gov (United States)

    Sugai, Mikiya

    2003-02-01

    Fresenius AS.TEC204 is a third-generation blood cell separator that incorporates the continuous centrifugal separation method and automatic control of the cell separation process. Continuous centrifugation separates cell components according to their specific gravity, and different cell components are either harvested or eliminated as needed. The interface between the red blood cell and plasma is optically detected, and the Interface Control (IFC) cooperates with different pumps, monitors and detectors to harvest required components automatically. The system is composed of three major sections; the Front Panel Unit; the Pump Unit, and the Centrifuge Unit. This unit can be used for a wide variety of clinical applications including collection of platelets, peripheral blood stem cells, bone marrow stem cells, granulocytes, mononuclear cells, and exchange of plasma or red cells, and for plasma treatment.

  1. Digital processing data communication systems (bus systems). Digitale Prozessdaten-Kommunikations-Systeme (Bus Systeme)

    Energy Technology Data Exchange (ETDEWEB)

    Fleck, K

    1980-01-01

    After an introduction to the technology of digital processing data communication systems there are the following chapters: digital communication of processing data in automation technology, the technology of biserial communication, the implementaiton of a bus system, the data transmission of the TDC-2000 system of Honeywell's and the process bus CS 275 in the automation system TELEPERM M of Siemens AG.

  2. The male reproductive system and the effect of an extract of a medicinal plant (Hypericum perforatum) on the labeling process of blood constituents with technetium-99m

    Energy Technology Data Exchange (ETDEWEB)

    Santos-Filho, Sebastiao David [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Universidade Federal do Rio Grande do Norte (UFRN), Natal, RN (Brazil)]. E-mail: santos-filho@uerj.br; Fonseca, Adenilson de Souza da [Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil). Inst. de Biologia Roberto Alcantara Gomes. Lab. de Radiofarmacia Experimental; Bernardo-Filho, Mario [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil). Coordenadoria de Pesquisa

    2007-09-15

    Hypericum perforatum (hiperico) is a plant that has been used to treat diseases and also inhibits rat and human vas deferens contractility. In nuclear medicine, stannous chloride (SnCl{sub 2}) is used as a reducing agent to obtain radiopharmaceuticals labeling with technetium-99m. As the SnCl{sub 2} seems to have adverse effects related with the reproductive performance of male rabbits as well as the human consumption of hiperico might affect sexual function. In the present work, consistent results show significant changes on the blood constituents labeled by technetium-99m obtained from young rats under the effect of an hiperico extract as opposed to blood samples equally treated taken from elderly rat. Supposedly, this extract could protect the male reproductive system against action of SnCl{sub 2} at least in young rats. The findings described in this work allow introducing a simple assay to evaluate the action of products that could interfere with the male reproductive system. (author)

  3. The male reproductive system and the effect of an extract of a medicinal plant (Hypericum perforatum) on the labeling process of blood constituents with technetium-99m

    International Nuclear Information System (INIS)

    Santos-Filho, Sebastiao David; Fonseca, Adenilson de Souza da; Bernardo-Filho, Mario

    2007-01-01

    Hypericum perforatum (hiperico) is a plant that has been used to treat diseases and also inhibits rat and human vas deferens contractility. In nuclear medicine, stannous chloride (SnCl 2 ) is used as a reducing agent to obtain radiopharmaceuticals labeling with technetium-99m. As the SnCl 2 seems to have adverse effects related with the reproductive performance of male rabbits as well as the human consumption of hiperico might affect sexual function. In the present work, consistent results show significant changes on the blood constituents labeled by technetium-99m obtained from young rats under the effect of an hiperico extract as opposed to blood samples equally treated taken from elderly rat. Supposedly, this extract could protect the male reproductive system against action of SnCl 2 at least in young rats. The findings described in this work allow introducing a simple assay to evaluate the action of products that could interfere with the male reproductive system. (author)

  4. Integrating system safety into the basic systems engineering process

    Science.gov (United States)

    Griswold, J. W.

    1971-01-01

    The basic elements of a systems engineering process are given along with a detailed description of what the safety system requires from the systems engineering process. Also discussed is the safety that the system provides to other subfunctions of systems engineering.

  5. Linearity analysis and comparison study on the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients

    Directory of Open Access Journals (Sweden)

    Jianing Chen

    2016-03-01

    Full Text Available The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.

  6. Process information systems in nuclear reprocessing

    International Nuclear Information System (INIS)

    Jaeschke, A.; Keller, H.; Orth, H.

    1987-01-01

    On a production management level, a process information system in a nuclear reprocessing plant (NRP) has to fulfill conventional operating functions and functions for nuclear material surveillance (safeguards). Based on today's state of the art of on-line process control technology, the progress in hardware and software technology allows to introduce more process-specific intelligence into process information systems. Exemplified by an expert-system-aided laboratory management system as component of a NRP process information system, the paper demonstrates that these technologies can be applied already. (DG) [de

  7. Serotonin and Blood Pressure Regulation

    Science.gov (United States)

    Morrison, Shaun F.; Davis, Robert Patrick; Barman, Susan M.

    2012-01-01

    5-Hydroxytryptamine (5-HT; serotonin) was discovered more than 60 years ago as a substance isolated from blood. The neural effects of 5-HT have been well investigated and understood, thanks in part to the pharmacological tools available to dissect the serotonergic system and the development of the frequently prescribed selective serotonin-reuptake inhibitors. By contrast, our understanding of the role of 5-HT in the control and modification of blood pressure pales in comparison. Here we focus on the role of 5-HT in systemic blood pressure control. This review provides an in-depth study of the function and pharmacology of 5-HT in those tissues that can modify blood pressure (blood, vasculature, heart, adrenal gland, kidney, brain), with a focus on the autonomic nervous system that includes mechanisms of action and pharmacology of 5-HT within each system. We compare the change in blood pressure produced in different species by short- and long-term administration of 5-HT or selective serotonin receptor agonists. To further our understanding of the mechanisms through which 5-HT modifies blood pressure, we also describe the blood pressure effects of commonly used drugs that modify the actions of 5-HT. The pharmacology and physiological actions of 5-HT in modifying blood pressure are important, given its involvement in circulatory shock, orthostatic hypotension, serotonin syndrome and hypertension. PMID:22407614

  8. Microfluidic-Based Bacteria Isolation from Whole Blood for Diagnostics of Blood Stream Infection.

    Science.gov (United States)

    Zelenin, Sergey; Ramachandraiah, Harisha; Faridi, Asim; Russom, Aman

    2017-01-01

    Bacterial blood stream infection (BSI) potentially leads to life-threatening clinical conditions and medical emergencies such as severe sepsis, septic shock, and multi organ failure syndrome. Blood culturing is currently the gold standard for the identification of microorganisms and, although it has been automated over the decade, the process still requires 24-72 h to complete. This long turnaround time, especially for the identification of antimicrobial resistance, is driving the development of rapid molecular diagnostic methods. Rapid detection of microbial pathogens in blood related to bloodstream infections will allow the clinician to decide on or adjust the antimicrobial therapy potentially reducing the morbidity, mortality, and economic burden associated with BSI. For molecular-based methods, there is a lot to gain from an improved and straightforward method for isolation of bacteria from whole blood for downstream processing.We describe a microfluidic-based sample-preparation approach that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100 % viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.

  9. Process-aware information systems : lessons to be learned from process mining

    NARCIS (Netherlands)

    Aalst, van der W.M.P.; Jensen, K.; Aalst, van der W.M.P.

    2009-01-01

    A Process-Aware Information System (PAIS) is a software system that manages and executes operational processes involving people, applications, and/or information sources on the basis of process models. Example PAISs are workflow management systems, case-handling systems, enterprise information

  10. Performance of a new test strip for freestyle blood glucose monitoring systems.

    Science.gov (United States)

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  11. [Prospects in blood transfusion].

    Science.gov (United States)

    Rouger, P

    2003-04-01

    What will be the evolution of blood transfusion in the next 10 years? What are the scientific and medical arguments to help the decision makers to propose the developments? Many scientific and clinical studies show that blood substitutes are not ready for use in man. So, for a long time, blood collection in man will still be a necessity to prepare cell concentrates (red blood cells and platelets) and fresh frozen plasma. During this period, blood safety will be based on development of testing technics and preparation processes of blood products. Another major point will be a better clinical use of blood derivates. Cellular therapy will be probably only a way of diversification in blood transfusion centers in partnership with hospitals.

  12. Blood pressure and blood flow variation during postural change from sitting to standing: model development and validation

    DEFF Research Database (Denmark)

    Olufsen, M.S.; Ottesen, Johnny T.; Tran, H.T.

    2005-01-01

    Short-term cardiovascular responses to postural change from sitting to standing involve complex interactions between the autonomic nervous system, which regulates blood pressure, and cerebral autoregulation, which maintains cerebral perfusion. We present a mathematical model that can predict...... dynamic changes in beat-to-beat arterial blood pressure and middle cerebral artery blood flow velocity during postural change from sitting to standing. Our cardiovascular model utilizes 11 compartments to describe blood pressure, blood flow, compliance, and resistance in the heart and systemic circulation....... To include dynamics due to the pulsatile nature of blood pressure and blood flow, resistances in the large systemic arteries are modeled using nonlinear functions of pressure. A physiologically based submodel is used to describe effects of gravity on venous blood pooling during postural change. Two types...

  13. Monooxignase ensymic system of a liver of rats exposed to intravascular laser irradiation of blood

    International Nuclear Information System (INIS)

    Ibadova, G.A.

    1997-01-01

    Experimental study of the dynamic monooxidation of liver enzymic system was carried out on rats with experimental salmonellosis and the influence of the blood intravascular laser irradiation of blood on these enzymes was revealed. It was determined that by experimental salmonellosis oppression of the MOES activity of hepatocytes occurred. The blood intravascular irradiation by He-Ne laser promotes MOES oppression in rats suffered from salmonellosis. IVLIB as well as UV-laser show pronounced effect on the enzymes detoxication protection, mobilize their resistance to endogenic intoxication under the conditions of experimental salmonellosis. (author)

  14. Risk analysis and detection of thrombosis by measurement of electrical resistivity of blood.

    Science.gov (United States)

    Sapkota, Achyut; Asakura, Yuta; Maruyama, Osamu; Kosaka, Ryo; Yamane, Takashi; Takei, Masahiro

    2013-01-01

    Monitoring of thrombogenic process is very important in ventricular assistance devices (VADs) used as temporary or permanent measures in patients with advanced heart failure. Currently, there is a lack of a system which can perform a real-time monitoring of thrombogenic activity. Electrical signals vary according to the change in concentration of coagulation factors as well as the distribution of blood cells, and thus have potential to detect the thrombogenic process in an early stage. In the present work, we have made an assessment of an instrumentation system exploiting the electrical properties of blood. The experiments were conducted using bovine blood. Electrical resistance tomography with eight-electrode sensor was used to monitor the spatio-temporal change in electrical resistivity of blood in thrombogenic and non-thrombogenic condition. Under non-thrombogenic condition, the resistivity was uniform across the cross-section and average resistivity monotonically decreased with time before remaining almost flat. In contrary, under thrombogenic condition, there was non-uniform distribution across the cross-section, and average resistivity fluctuated with time.

  15. Establishing and evaluating bar-code technology in blood sampling system: a model based on human centered human-centered design method.

    Science.gov (United States)

    Chou, Shin-Shang; Yan, Hsiu-Fang; Huang, Hsiu-Ya; Tseng, Kuan-Jui; Kuo, Shu-Chen

    2012-01-01

    This study intended to use a human-centered design study method to develop a bar-code technology in blood sampling process. By using the multilevel analysis to gather the information, the bar-code technology has been constructed to identify the patient's identification, simplify the work process, and prevent medical error rates. A Technology Acceptance Model questionnaire was developed to assess the effectiveness of system and the data of patient's identification and sample errors were collected daily. The average scores of 8 items users' perceived ease of use was 25.21(3.72), 9 items users' perceived usefulness was 28.53(5.00), and 14 items task-technology fit was 52.24(7.09), the rate of patient identification error and samples with order cancelled were down to zero, however, new errors were generated after the new system deployed; which were the position of barcode stickers on the sample tubes. Overall, more than half of nurses (62.5%) were willing to use the new system.

  16. Implementation of good manufacturing practices (GMP) on human blood irradiation

    International Nuclear Information System (INIS)

    Boghi, Claudio; Napolitano, Celia M.; Ferreira, Danilo C.; Rela, Paulo Roberto; Zarate, Herman S.

    2007-01-01

    The irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease), a rare but devastating adverse effect of leukocytes present in blood components for a immuno-competent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of lymphocytes. The implementation of the GMP will assure that the properly dose in a range of 25 Gy to 50 Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies to establish the GMP were developed under the guidelines of the standard ISO 11137 - Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO 4 : Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, trace ability and calibration system. The PMMA and gafchromic dosimetric systems have shown a better performance and were adopted on establishment of GMP procedures. The irradiation tests have been done using a Gammacell 220 Irradiator. The developed GMP can be adapted for different types of gamma irradiators, allowing to set up a quality assurance program for blood irradiation. (author)

  17. Implementation of good manufacturing practices (GMP) on human blood irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Boghi, Claudio; Napolitano, Celia M.; Ferreira, Danilo C.; Rela, Paulo Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: cboghi@uol.com.br; cmnapoli@ipen.br; dancarde@ig.com.br; prela@ipen.br; Zarate, Herman S. [Comission Chilena de Energia Nuclear, Santiago (Chile)]. E-mail: hzarate@cchen.cl

    2007-07-01

    The irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease), a rare but devastating adverse effect of leukocytes present in blood components for a immuno-competent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of lymphocytes. The implementation of the GMP will assure that the properly dose in a range of 25 Gy to 50 Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies to establish the GMP were developed under the guidelines of the standard ISO 11137 - Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO{sub 4}: Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, trace ability and calibration system. The PMMA and gafchromic dosimetric systems have shown a better performance and were adopted on establishment of GMP procedures. The irradiation tests have been done using a Gammacell 220 Irradiator. The developed GMP can be adapted for different types of gamma irradiators, allowing to set up a quality assurance program for blood irradiation. (author)

  18. Proteolytic system of blood-feeding ticks: An update on protein structures

    Czech Academy of Sciences Publication Activity Database

    Kovářová, Zuzana; Hobizalová, Radka; Žebrakovská, Iva; Brynda, Jiří; Řezáčová, Pavlína; Horn, Martin; Mareš, Michael

    2015-01-01

    Roč. 22, č. 1 (2015), s. 43-44 ISSN 1211-5894. [Discussions in Structural Molecular Biology. Annual Meeting of the Czech Society for Structural Biology /13./. 19.03.2015-21.03.2015, Nové Hrady] Institutional support: RVO:61388963 ; RVO:68378050 Keywords : blood-feeding ticks * protein structure * proteolytic system Subject RIV: CE - Biochemistry

  19. Online data processing system

    International Nuclear Information System (INIS)

    Nakahara, Yoshinori; Yagi, Hideyuki; Yamada, Takayuki

    1979-02-01

    A pulse height analyzer terminal system PHATS has been developed for online data processing via JAERI-TOKAI computer network. The system is controled by using a micro-computer MICRO-8 which was developed for the JAERI-TOKAI network. The system program consists of two subprograms, online control system ONLCS and pulse height analyzer control system PHACS. ONLCS links the terminal with the conversational programming system of FACOM 230/75 through the JAERI-TOKAI network and controls data processing in TSS and remote batch modes. PHACS is used to control INPUT/OUTPUT of data between pulse height analyzer and cassette-MT or typewriter. This report describes the hardware configuration and the system program in detail. In the appendix, explained are real time monitor, type of message, PEX to PEX protocol and Host to Host protocol, required for the system programming. (author)

  20. Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems.

    Science.gov (United States)

    Somily, Ali Mohammed; Habib, Hanan Ahmed; Torchyan, Armen Albert; Sayyed, Samina B; Absar, Muhammed; Al-Aqeel, Rima; Binkhamis, A Khalifa

    2018-01-01

    Bloodstream infections are associated with high rates of morbidity and mortality. Rapid detection of bloodstream infections is important in achieving better patient outcomes. Compare the time-to-detection (TTD) of the new BacT/Alert Virtuo and the BACTEC FX automated blood culture systems. Prospective simulated comparison of two instruments using seeded samples. Medical microbiology laboratory. Blood culture bottles were seeded in triplicate with each of the standard ATCC strains of aerobes, anaerobes and yeast. TTD was calculated as the length of time from the beginning of culture incubation to the detection of bacterial growth. TTD for the various tested organisms on the two microbial detection systems. The 99 bottles of seeded blood cultures incubated in each of the blood culture systems included 21 anaerobic, 39 aerobic and 39 pediatric bottles. The BacT/Alert Virtuo system exhibited significantly shorter TTD for 72.7 % of the tested organisms compared to BACTEC FX system with a median difference in mean TTD of 2.1 hours (interquartile range: 1.5-3.5 hours). The BACTEC FX system was faster in 15.2% (5/33) of microorganisms, with a median difference in mean TTD of 25.9 hours (IQR: 9.1-29.2 hours). TTD was significantly shorter for most of the microorganisms tested on the new BacT/Alert Virtuo system compared to the BACTEC FX system. Use of simulated cultures to assess TTD may not precisely represent clinical blood cultures. None.

  1. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W. Sr.

    1992-01-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system use relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, Monte Carlo calculations were performed using the code Electron Gamma Shower (EGS4). Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessel sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was or cross fire between blood vessels was assumed. Results are useful in assessing the doses to blood and blood vessel walls for different nuclear medicine procedures

  2. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    Science.gov (United States)

    Phelan, Michael P; Reineks, Edmunds Z; Hustey, Fredric M; Berriochoa, Jacob P; Podolsky, Seth R; Meldon, Stephen; Schold, Jesse D; Chamberlin, Janelle; Procop, Gary W

    2016-09-01

    Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]). Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99]) or mild (10.3% vs 9.8% [p=0.88]) hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%-14.6%). We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material). Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  3. Abnormalities in the cellular phase of blood fibrinolytic activity in systemic lupus erythematosus and in venous thromboembolism

    International Nuclear Information System (INIS)

    Moroz, L.A.; MacLean, L.D.; Langleben, D.

    1986-01-01

    Fibrinolytic activities of whole blood and plasma were determined by 125 I-fibrin radiometric assay in 16 normal subjects, and in 11 patients with systemic lupus erythematosus (SLE), 14 with progressive systemic sclerosis (PSS), 23 with venous thromboembolic disease, and 20 patients awaiting elective surgery. Mean whole blood and plasma activities for patients with PSS, and for those awaiting elective surgery, were similar to normal values, as was the mean plasma activity in patients with SLE. However, mean whole blood activity in SLE was significantly decreased compared with normals (p less than 0.05), with mean plasma activity accounting for 44% of mean whole blood activity (compared with 17% in normal subjects), representing a 67% decrease in mean calculated cellular phase activity in SLE, when compared with normals. Since the numbers of cells (neutrophils, monocytes) possibly involved in cellular activity were not decreased, the findings suggest a functional defect in fibrinolytic activity of one or more blood cell types in SLE. An additional finding was the participation of the cellular phase as well as the well-known plasma phase of blood in the fibrinolytic response to thromboembolism

  4. Artificial blood-flow controlling effects of inhomogeneity of twisted magnetic fields

    International Nuclear Information System (INIS)

    Nakagawa, Hidenori; Ohuchi, Mikio

    2017-01-01

    We developed a blood-flow controlling system using magnetic therapy for some types of nervous diseases. In our research, we utilized overlapped extremely low frequency (ELF) fields for the most effective blood-flow for the system. Results showed the possibility that the inhomogeneous region obtained by overlapping the fields at 50 Hz, namely, a desirably twisted field revealed a significant difference in induced electromotive forces at the insertion points of electrodes. In addition, ELF exposures with a high inhomogeneity of the twisted field at 50 Hz out of phase were more effective in generating an induced electromotive difference by approximately 31%, as contrasted with the difference generated by the exposure in phase. We expect that the increase of the inhomogeneity of the twisted field around a blood vessel can produce the most effective electromotive difference in the blood, and also moderately affect the excitable cells relating to the autonomic nervous system for an outstanding blood-flow control in vivo. - Highlights: • The principal aim of this research is to contribute to the utilization of the twisted fields for the most effective blood-flow in vivo. • Two newly designed coil systems were used for producing a desirably twisted magnetic field under the measuring domain in the flow channel. • Further, we investigated the magnetohydrodynamic efficiencies of a prototype of a magnetic device, which was converted from use as a commercial alternating magnetic therapy apparatus. • The system was well-constructed with a successful application of a plural exposure coil; therefore, we were able to detect a maximum of induced electromotive force in a fluid of an artificial solution as a substitute for blood. • This new finding demonstrates that the process of blood massotherapy by magnetic stimuli is a therapy for many diseases.

  5. Artificial blood-flow controlling effects of inhomogeneity of twisted magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hidenori, E-mail: hnakagawa-tdt@umin.ac.jp; Ohuchi, Mikio

    2017-06-01

    We developed a blood-flow controlling system using magnetic therapy for some types of nervous diseases. In our research, we utilized overlapped extremely low frequency (ELF) fields for the most effective blood-flow for the system. Results showed the possibility that the inhomogeneous region obtained by overlapping the fields at 50 Hz, namely, a desirably twisted field revealed a significant difference in induced electromotive forces at the insertion points of electrodes. In addition, ELF exposures with a high inhomogeneity of the twisted field at 50 Hz out of phase were more effective in generating an induced electromotive difference by approximately 31%, as contrasted with the difference generated by the exposure in phase. We expect that the increase of the inhomogeneity of the twisted field around a blood vessel can produce the most effective electromotive difference in the blood, and also moderately affect the excitable cells relating to the autonomic nervous system for an outstanding blood-flow control in vivo. - Highlights: • The principal aim of this research is to contribute to the utilization of the twisted fields for the most effective blood-flow in vivo. • Two newly designed coil systems were used for producing a desirably twisted magnetic field under the measuring domain in the flow channel. • Further, we investigated the magnetohydrodynamic efficiencies of a prototype of a magnetic device, which was converted from use as a commercial alternating magnetic therapy apparatus. • The system was well-constructed with a successful application of a plural exposure coil; therefore, we were able to detect a maximum of induced electromotive force in a fluid of an artificial solution as a substitute for blood. • This new finding demonstrates that the process of blood massotherapy by magnetic stimuli is a therapy for many diseases.

  6. Negative peri-donation events among whole blood donors in a blood bank in Ibadan, Nigeria.

    Science.gov (United States)

    Fasola, Foluke A

    2017-12-31

    The existence and sustenance of the blood bank depends on blood donors. It is imperative that the donation experience is satisfactory for the donors. Therefore this study was carried out to determine the frequency of undesirable events experienced by the blood donor as part of donor haemovigilance. This was a retrospective descriptive study of the events that occurred amongst the blood donors of the blood bank of a tertiary institution. The blood donor incident book was reviewed for the period of six months. Negative undesirable events occurred in 2% of the donor populations, of which 45.8% could not complete the blood donation process while only 16.7% completed the blood donation process. Mild vasovagal attack occurred in 0.2% of the donor population. Undisclosed deferrable risk factors/ behaviours were identified by the phlebotomist in the bleeding room which made donors unfit for donation even though they had passed the donor screening criteria. This accounted for 20.8% of those with negative experience. Guidelines are required to identify donors that are not likely to complete donation to avoid wastage of time, blood, resources and reduce undesirable experiences.

  7. A Mathematical Model of Renal Blood Distribution Coupling TGF, MR and Tubular System

    Institute of Scientific and Technical Information of China (English)

    GAO Ci-xiu; YANG Lin; WANG Ke-qiang; XU Shi-xiong; DAI Pei-dong

    2009-01-01

    Objective:To investigate the relationship between renal blood distribution and the physiological activities of the kidney. Methods:A mathematical model is developed based on Hagan-Poiseuille law and mass transport, coupling mechanics of myogenic response (MR), tubuloglomerular feedback (TGF) and the tubular system in the renal medulla. The model parameters, including the permeability coefficients, the vascular lumen radius and the solute concentration at the inlet of the tubes, are derived from the experimental results. Simulations of the blood and water flow in the loop of Henel, the collecting duct and vas rectum, are carried out by the model of the tubular system in the renal medulla, based on conservations of water and solutes for transmural transport. Then the tubular model is coupled with MR and TGF mechanics. Results:The results predict the dynamics of renal autoregulation on its blood pressure and flow,and the distributions are 88.5% in the cortex, 10.3% in the medulla, and 1.2% at papilla,respectively. The fluid flow and solute concentrations along the tubules and vasa recta are obtained. Conclusion:The present model could assess renal functions qualitatively and quantitatively and provide a methodological approach for clinical research.

  8. Blood Pressure Management in Cardiovascular Risk Stratification. Procedure, Progression, Process.

    NARCIS (Netherlands)

    Adiyaman, A.

    2009-01-01

    In this thesis we have explored different aspects of blood pressure measurement and related it to the risk of cardiovascular disease. In the first part we showed that when the arm is positioned under heart level, for example when the arm is placed on a desk or a chair support, the blood pressure and

  9. Examples of data processing systems. Data processing system for JT-60

    International Nuclear Information System (INIS)

    Aoyagi, Tetsuo

    1996-01-01

    JT-60 data processing system is a large computer complex system including a lot of micro-computers, several mini-computers, and a main-frame computer. As general introduction of the original system configuration has been published previously, some improvements are described here. Transient mass data storage system, network database server, a data acquisition system using engineering workstations, and a graphic terminal emulator for X-Window are presented. These new features are realized by utilizing recent progress in computer and network technology and carefully designed user interface specification of the original system. (author)

  10. Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013.

    Science.gov (United States)

    Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Jendrike, Nina; Haug, Cornelia; Freckmann, Guido

    2016-05-01

    Objective For patients with diabetes, regular self-monitoring of blood glucose (SMBG) is essential to ensure adequate glycemic control. Therefore, accurate and reliable blood glucose measurements with SMBG systems are necessary. The international standard ISO 15197 describes requirements for SMBG systems, such as limits within which 95% of glucose results have to fall to reach acceptable system accuracy. The 2013 version of this standard sets higher demands, especially regarding system accuracy, than the currently still valid edition. ISO 15197 can be applied by manufacturers to receive a CE mark for their system. Research design and methods This study was an accuracy evaluation following ISO 15197:2013 section 6.3 of two recently updated SMBG systems (Contour * and Contour TS; Bayer Consumer Care AG, Basel, Switzerland) with an improved algorithm to investigate whether the systems fulfill the requirements of the new standard. For this purpose, capillary blood samples of approximately 100 participants were measured with three test strip lots of both systems and deviations from glucose values obtained with a hexokinase-based comparison method (Cobas Integra † 400 plus; Roche Instrument Center, Rotkreuz, Switzerland) were determined. Percentages of values within the acceptance criteria of ISO 15197:2013 were calculated. This study was registered at clinicaltrials.gov (NCT02358408). Main outcome Both updated systems fulfilled the system accuracy requirements of ISO 15197:2013 as 98.5% to 100% of the results were within the stipulated limits. Furthermore, all results were within the clinically non-critical zones A and B of the consensus error grid for type 1 diabetes. Conclusions The technical improvement of the systems ensured compliance with ISO 15197 in the hands of healthcare professionals even in its more stringent 2013 version. Alternative presentation of system accuracy results in radar plots provides additional information with certain advantages. In addition

  11. A blood pressure monitor with robust noise reduction system under linear cuff inflation and deflation.

    Science.gov (United States)

    Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi

    2010-01-01

    We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.

  12. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  13. A review of blood sample handling and pre-processing for metabolomics studies.

    Science.gov (United States)

    Hernandes, Vinicius Veri; Barbas, Coral; Dudzik, Danuta

    2017-09-01

    Metabolomics has been found to be applicable to a wide range of clinical studies, bringing a new era for improving clinical diagnostics, early disease detection, therapy prediction and treatment efficiency monitoring. A major challenge in metabolomics, particularly untargeted studies, is the extremely diverse and complex nature of biological specimens. Despite great advances in the field there still exist fundamental needs for considering pre-analytical variability that can introduce bias to the subsequent analytical process and decrease the reliability of the results and moreover confound final research outcomes. Many researchers are mainly focused on the instrumental aspects of the biomarker discovery process, and sample related variables sometimes seem to be overlooked. To bridge the gap, critical information and standardized protocols regarding experimental design and sample handling and pre-processing are highly desired. Characterization of a range variation among sample collection methods is necessary to prevent results misinterpretation and to ensure that observed differences are not due to an experimental bias caused by inconsistencies in sample processing. Herein, a systematic discussion of pre-analytical variables affecting metabolomics studies based on blood derived samples is performed. Furthermore, we provide a set of recommendations concerning experimental design, collection, pre-processing procedures and storage conditions as a practical review that can guide and serve for the standardization of protocols and reduction of undesirable variation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. SMA Diagnosis: Detection of SMN1 Deletion with Real-Time mCOP-PCR System Using Fresh Blood DNA.

    Science.gov (United States)

    Niba, Emma Tabe Eko; Ar Rochmah, Mawaddah; Harahap, Nur Imma Fatimah; Awano, Hiroyuki; Morioka, Ichiro; Iijima, Kazumoto; Saito, Toshio; Saito, Kayoko; Takeuchi, Atsuko; Lai, Poh San; Bouike, Yoshihiro; Nishio, Hisahide; Shinohara, Masakazu

    2017-12-18

    Spinal muscular atrophy (SMA) is one of the most common autosomal recessive disorders. The symptoms are caused by defects of lower motor neurons in the spinal cord. More than 95% of SMA patients are homozygous for survival motor neuron 1 (SMN1) deletion. We previously developed a screening system for SMN1 deletion based on a modified competitive oligonucleotide priming-PCR (mCOP-PCR) technique using dried blood spot (DBS) on filter paper. This system is convenient for mass screening in the large population and/or first-tier diagnostic method of the patients in the remote areas. However, this system was still time-consuming and effort-taking, because it required pre-amplification procedure to avoid non-specific amplification and gel-electrophoresis to detect the presence or absence of SMN1 deletion. When the fresh blood samples are used instead of DBS, or when the gel-electrophoresis is replaced by real-time PCR, we may have a simpler and more rapid diagnostic method for SMA. To establish a simpler and more rapid diagnostic method of SMN1 deletion using fresh blood DNA. DNA samples extracted from fresh blood and stored at 4 ℃ for 1 month. The samples were assayed using a real-time mCOP-PCR system without pre-amplification procedures. DNA samples had already been genotyped by PCR-restriction fragment length polymorphism (PCR-RFLP), showing the presence or absence of SMN1 exon 7. The DNA samples were directly subjected to the mCOP-PCR step. The amplification of mCOP-PCR was monitored in a real-time PCR apparatus. The genotyping results of the real-time mCOP-PCR system using fresh blood DNA were completely matched with those of PCR-RFLP. In this real-time mCOP-PCR system using fresh blood-DNA, it took only four hours from extraction of DNA to detection of the presence or absence of SMN1 deletion, while it took more than 12 hours in PCR-RFLP. Our real-time mCOP-PCR system using fresh blood DNA was rapid and accurate, suggesting it may be useful for the first

  15. Security of legacy process control systems : Moving towards secure process control systems

    NARCIS (Netherlands)

    Oosterink, M.

    2012-01-01

    This white paper describes solutions which organisations may use to improve the security of their legacy process control systems. When we refer to a legacy system, we generally refer to old methodologies, technologies, computer systems or applications which are still in use, despite the fact that

  16. Effect of low frequency magnetic field at reproductive system state and peroxidation processes in liver of male rates after low dose chronic irradiation

    International Nuclear Information System (INIS)

    Konoplya, E.F.; Vereshchako, G.T.; Popov, E.G.; Khodosovskaya, A.M.; Artemenko, A.M.; Bulovatskaya, I.V.; Rybakov, V.N.

    2002-01-01

    Low frequency magnetic field (power 3.5 wt, tension 8v, amplitude 15 Tl, frequency of followed impulses 10 Hz, frequency of exposure 70-90 Hz) significantly modified the morphofunctional state of the reproductive system and peroxidation processes in liver of male rates. It concluded in a partial restoration of testicular weight, a recovery of the blood serum testosterone levels and of the molecular characteristics of the androgen receptor system in liver and testes, a normalization of peroxidation processes in liver and a stimulation of some biochemical and bioenergetic processes in testes (authors)

  17. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  18. Absorbed dose calculations to blood and blood vessels for internally deposited radionuclides

    International Nuclear Information System (INIS)

    Akabani, G.; Poston, J.W.

    1991-05-01

    At present, absorbed dose calculations for radionuclides in the human circulatory system used relatively simple models and are restricted in their applications. To determine absorbed doses to the blood and to the surface of the blood vessel wall, EGS4 Monte Carlo calculations were performed. Absorbed doses were calculated for the blood and the blood vessel wall (lumen) for different blood vessels sizes. The radionuclides chosen for this study were those commonly used in nuclear medicine. No diffusion of the radionuclide into the blood vessel was assumed nor cross fire between vessel was assumed. Results are useful in assessing the dose in blood and blood vessel walls for different nuclear medicine procedures. 6 refs., 6 figs., 5 tabs

  19. Fundamentals of process intensification: A process systems engineering view

    DEFF Research Database (Denmark)

    Babi, Deenesh Kavi; Sales Cruz, Alfonso Mauricio; Gani, Rafiqul

    2016-01-01

    This chapter gives an overview of the fundamentals of process intensification from a process systems engineering point of view. The concept of process intensification, including process integration, is explained together with the drivers for applying process intensification, which can be achieved...

  20. Remote Blood Glucose Monitoring in mHealth Scenarios: A Review

    Directory of Open Access Journals (Sweden)

    Giordano Lanzola

    2016-11-01

    Full Text Available Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient’s significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators.

  1. Characterization of 3-Dimensional PET Systems for Accurate Quantification of Myocardial Blood Flow.

    Science.gov (United States)

    Renaud, Jennifer M; Yip, Kathy; Guimond, Jean; Trottier, Mikaël; Pibarot, Philippe; Turcotte, Eric; Maguire, Conor; Lalonde, Lucille; Gulenchyn, Karen; Farncombe, Troy; Wisenberg, Gerald; Moody, Jonathan; Lee, Benjamin; Port, Steven C; Turkington, Timothy G; Beanlands, Rob S; deKemp, Robert A

    2017-01-01

    Three-dimensional (3D) mode imaging is the current standard for PET/CT systems. Dynamic imaging for quantification of myocardial blood flow with short-lived tracers, such as 82 Rb-chloride, requires accuracy to be maintained over a wide range of isotope activities and scanner counting rates. We proposed new performance standard measurements to characterize the dynamic range of PET systems for accurate quantitative imaging. 82 Rb or 13 N-ammonia (1,100-3,000 MBq) was injected into the heart wall insert of an anthropomorphic torso phantom. A decaying isotope scan was obtained over 5 half-lives on 9 different 3D PET/CT systems and 1 3D/2-dimensional PET-only system. Dynamic images (28 × 15 s) were reconstructed using iterative algorithms with all corrections enabled. Dynamic range was defined as the maximum activity in the myocardial wall with less than 10% bias, from which corresponding dead-time, counting rates, and/or injected activity limits were established for each scanner. Scatter correction residual bias was estimated as the maximum cavity blood-to-myocardium activity ratio. Image quality was assessed via the coefficient of variation measuring nonuniformity of the left ventricular myocardium activity distribution. Maximum recommended injected activity/body weight, peak dead-time correction factor, counting rates, and residual scatter bias for accurate cardiac myocardial blood flow imaging were 3-14 MBq/kg, 1.5-4.0, 22-64 Mcps singles and 4-14 Mcps prompt coincidence counting rates, and 2%-10% on the investigated scanners. Nonuniformity of the myocardial activity distribution varied from 3% to 16%. Accurate dynamic imaging is possible on the 10 3D PET systems if the maximum injected MBq/kg values are respected to limit peak dead-time losses during the bolus first-pass transit. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  2. The development of a national surveillance system for monitoring blood use and inventory levels at sentinel hospitals in South Korea.

    Science.gov (United States)

    Lim, Y A; Kim, H H; Joung, U S; Kim, C Y; Shin, Y H; Lee, S W; Kim, H J

    2010-04-01

    We developed a web-based program for a national surveillance system to determine baseline data regarding the supply and demand of blood products at sentinel hospitals in South Korea. Sentinel hospitals were invited to participate in a 1-month pilot-test. The data for receipts and exports of blood from each hospital information system were converted into comma-separated value files according to a specific conversion rule. The daily data from the sites could be transferred to the web-based program server using a semi-automated submission procedure: pressing a key allowed the program to automatically compute the blood inventory level as well as other indices including the minimal inventory ratio (MIR), ideal inventory ratio (IIR), supply index (SI) and utilisation index (UI). The national surveillance system was referred to as the Korean Blood Inventory Monitoring System (KBIMS) and the web-based program for KBIMS was referred to as the Blood Inventory Monitoring System (BMS). A total of 30 256 red blood cell (RBC) units were submitted as receipt data, however, only 83% of the receipt data were submitted to the BMS server as export data (25 093 RBC units). Median values were 2.67 for MIR, 1.08 for IIR, 1.00 for SI, 0.88 for UI and 5.33 for the ideal inventory day. The BMS program was easy to use and is expected to provide a useful tool for monitoring hospital inventory levels. This information will provide baseline data regarding the supply and demand of blood products in South Korea.

  3. A gamma cammera image processing system

    International Nuclear Information System (INIS)

    Chen Weihua; Mei Jufang; Jiang Wenchuan; Guo Zhenxiang

    1987-01-01

    A microcomputer based gamma camera image processing system has been introduced. Comparing with other systems, the feature of this system is that an inexpensive microcomputer has been combined with specially developed hardware, such as, data acquisition controller, data processor and dynamic display controller, ect. Thus the process of picture processing has been speeded up and the function expense ratio of the system raised

  4. Super-rapid medical film processing system

    International Nuclear Information System (INIS)

    Honda, C.; Iwata, M.; Nozaki, H.

    1988-01-01

    A new super-rapid medical film processing system cuts processing time from 90 to 45 seconds, a critical advantage in traumatic injury, surgical operation, and other time-vital applications. The system consists of new films new processing chemicals (developer and fixer), and a new high-speed medical film processor. The system's creation is made possible by three new technologies. In film, multilayered monodispersed grains reduce processing time. In processing chemicals, an innovative design maximizes processing speed. And in the processor itself, a new drying apparatus increases drying efficiency. Together, these technologies achieve 45-second processing without degradation of image quality

  5. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?

    Directory of Open Access Journals (Sweden)

    Fredric M. Hustey

    2016-09-01

    Full Text Available Introduction: Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. Methods: The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest® for potassium results for specimens obtained between January 2014 and July 2014. From facility maintenance records, we identified periods of system downtime, during which specimens were hand-carried to the laboratory. Results: During the study period, 15,851 blood specimens were transported via our pneumatic tube system and 92 samples were hand delivered. The proportions of hemolyzed specimens in the two groups were not significantly different (13.6% vs. 13.1% [p=0.90]. Results were consistent when the criterion was limited to gross (3.3% vs 3.3% [p=0.99] or mild (10.3% vs 9.8% [p=0.88] hemolysis. The hemolysis rate showed minimal variation during the study period (12.6%–14.6%. Conclusion: We found no statistical difference in the percentages of hemolyzed specimens transported by a pneumatic tube system or hand delivered to the laboratory. Certain features of pneumatic tube systems might contribute to hemolysis (e.g., speed, distance, packing material. Since each system is unique in design, we encourage medical facilities to consider whether their method of transport might contribute to hemolysis in samples obtained in the emergency department.

  6. Odors generated from the Maillard reaction affect autonomic nervous activity and decrease blood pressure through the olfactory system.

    Science.gov (United States)

    Zhou, Lanxi; Ohata, Motoko; Owashi, Chisato; Nagai, Katsuya; Yokoyama, Issei; Arihara, Keizo

    2018-02-01

    Systolic blood pressure (SBP) of rats decreases significantly following exposure to the odor generated from the Maillard reaction of protein digests with xylose. This study identified active odorants that affect blood pressure and demonstrated the mechanism of action. Among the four potent odorants that contribute most to the odor of the Maillard reaction sample, 2,5-dimethyl-4-hydroxy-3(2H)-furanone (DMHF) and 5-methyl-2-pyrazinemethanol (MPM) decreased SBP significantly. The earliest decrease in blood pressure was observed 5 min after exposure to DMHF. Application of zinc sulfate to the nasal cavity eliminated the effect. Furthermore, gastric vagal (parasympathetic) nerve activity was elevated and renal sympathetic nerve activity was lowered after exposure to DMHF. It is indicated that DMHF affects blood pressure through the olfactory system, and the mechanism for the effect of DMHF on blood pressure involves the autonomic nervous system. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  7. Aging: a portrait from gene expression profile in blood cells.

    Science.gov (United States)

    Calabria, Elisa; Mazza, Emilia Maria Cristina; Dyar, Kenneth Allen; Pogliaghi, Silvia; Bruseghini, Paolo; Morandi, Carlo; Salvagno, Gian Luca; Gelati, Matteo; Guidi, Gian Cesare; Bicciato, Silvio; Schiaffino, Stefano; Schena, Federico; Capelli, Carlo

    2016-08-01

    The availability of reliable biomarkers of aging is important not only to monitor the effect of interventions and predict the timing of pathologies associated with aging but also to understand the mechanisms and devise appropriate countermeasures. Blood cells provide an easily available tissue and gene expression profiles from whole blood samples appear to mirror disease states and some aspects of the aging process itself. We report here a microarray analysis of whole blood samples from two cohorts of healthy adult and elderly subjects, aged 43±3 and 68±4 years, respectively, to monitor gene expression changes in the initial phase of the senescence process. A number of significant changes were found in the elderly compared to the adult group, including decreased levels of transcripts coding for components of the mitochondrial respiratory chain, which correlate with a parallel decline in the maximum rate of oxygen consumption (VO2max), as monitored in the same subjects. In addition, blood cells show age-related changes in the expression of several markers of immunosenescence, inflammation and oxidative stress. These findings support the notion that the immune system has a major role in tissue homeostasis and repair, which appears to be impaired since early stages of the aging process.

  8. Renal blood flow regulation and arterial pressure fluctuations: a case study in nonlinear dynamics

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Marsh, D J

    1994-01-01

    in which the kidney is obliged to operate. Were it not for renal blood flow autoregulation, it would be difficult to regulate renal excretory processes so as to maintain whole body variables within narrow bounds. Autoregulation is the noise filter on which other renal processes depend for maintaining...... a relatively noise-free environment in which to work. Because of the time-varying nature of the blood pressure, we have concentrated in this review on the now substantial body of work on the dynamics of renal blood flow regulation and the underlying mechanisms. Renal vascular control mechanisms are not simply....... The significance of deterministic chaos in the context of renal blood flow regulation is that the system regulating blood flow undergoes a physical change to a different dynamical state, and because the change is deterministic, there is every expectation that the critical change will yield itself to experimental...

  9. Relation of unprocessed, processed red meat and poultry consumption to blood pressure in East Asian and Western adults

    NARCIS (Netherlands)

    Oude Griep, L.M.; Seferidi, Paraskevi; Stamler, J.; Horn, van L.; Chan, Queenie; Tzoulaki, Ioanna; Steffen, L.M.; Miura, K.; Ueshima, H.; Okuda, N.; Zhao, Liancheng; Soedamah-Muthu, S.S.; Daviglus, M.L.; Elliott, P.

    2016-01-01

    Background: Epidemiologic evidence suggests that relationships of red meat consumption with risk of cardiovascular diseases depends on whether or not the meat is processed, including addition of preservatives, but evidence is limited for blood pressure (BP). Objective: To examine cross-sectional

  10. A study of the blood flow restriction pressure of a tourniquet system to facilitate development of a system that can prevent musculoskeletal complications.

    Science.gov (United States)

    Maeda, Hiroyuki; Iwase, Hideaki; Kanda, Akio; Morohashi, Itaru; Kaneko, Kazuo; Maeda, Mutsuhiro; Kakinuma, Yuki; Takei, Yusuke; Amemiya, Shota; Mitsui, Kazuyuki

    2017-01-01

    After an emergency or disaster, subsequent trauma can cause severe bleeding and this can often prove fatal, so promptly stopping that bleeding is crucial to preventing avoidable trauma deaths. A tourniquet is often used to restrict blood flow to an extremity. In operation and hospital, the tourniquet systems currently in use are pneumatically actuated by an air compressor, so they must have a steady power supply. These devices have several drawbacks: they vibrate and are noisy since they are pneumatically actuated and they are far from portable since they are large and heavy. Presumably, the drawbacks of pneumatic tourniquets could be overcome by developing a small, lightweight, vibration-free, quiet, and battery-powered tourniquet system. The current study built a small, vibration-free electrohydrodynamic (EHD) pump and then used that pump to restrict blood flow to the leg of rats in an experiment. This study explored the optimal conditions for effective restriction of blood flow by assessing biochemical and musculoskeletal complications following the restriction of blood flow, and this study also examined whether or not an EHD pump could be used to actuate a tourniquet system. A tourniquet cuff (width 12 mm × length 150 mm, material: polyolefin) was placed on the thigh of Wistar rats and pressure was applied for 2 hours by a device that uses EHD phenomena to generate pressure (an EHD pump). Animals were divided into four groups based on how much compressive pressure was applied with a tourniquet: 40 kPa (300 mm Hg, n = 13), 30 kPa (225 mm Hg, n = 12), 20 kPa (150 mm Hg, n = 15), or 0 kPa (controls, n = 25). Tissue oxygen saturation (regional oxygen saturation, denoted here as rSO 2 ) was measured to assess the restriction of blood flow. To assess behavior once blood flow resumed, animal activity was monitored for third day and the amount of movement was counted with digital counters. Body weight was measured before and after the behavioral experiment, and

  11. The Integrity of the Corpus Callosum Mitigates the Impact of Blood Pressure on the Ventral Attention Network and Information Processing Speed in Healthy Adults

    Directory of Open Access Journals (Sweden)

    Tatia M. C. Lee

    2017-04-01

    Full Text Available Hypertension is a risk factor for cognitive impairment in older age. However, evidence of the neural basis of the relationship between the deterioration of cognitive function and elevated blood pressure is sparse. Based on previous research, we speculate that variations in brain connectivity are closely related to elevated blood pressure even before the onset of clinical conditions and apparent cognitive decline in individuals over 60 years of age. Forty cognitively healthy adults were recruited. Each received a blood pressure test before and after the cognitive assessment in various domains. Diffusion tensor imaging (DTI and resting-state functional magnetic resonance imaging (rsfMRI data were collected. Our findings confirm that elevated blood pressure is associated with brain connectivity variations in cognitively healthy individuals. The integrity of the splenium of the corpus callosum is closely related to individual differences in systolic blood pressure. In particular, elevated systolic blood pressure is related to resting-state ventral attention network (VAN and information processing speed. Serial mediation analyses have further revealed that lower integrity of the splenium statistically predicts elevated systolic blood pressure, which in turn predicts weakened functional connectivity (FC within the VAN and eventually poorer processing speed. The current study sheds light on how neural correlates are involved in the impact of elevated blood pressure on cognitive functioning.

  12. Performance evaluation of photoacoustic oximetry imaging systems using a dynamic blood flow phantom with tunable oxygen saturation

    Science.gov (United States)

    Vogt, William C.; Zhou, Xuewen; Andriani, Rudy; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2018-02-01

    Photoacoustic Imaging (PAI) is an emerging technology with strong potential for broad clinical applications from breast cancer detection to cerebral monitoring due to its ability to compute maps of blood oxygen saturation (SO2) distribution in deep tissues using multispectral imaging. However, no well-validated consensus test methods currently exist for evaluating oximetry-specific performance characteristics of PAI devices. We have developed a phantombased flow system capable of rapid SO2 adjustment to serve as a test bed for elucidation of factors impacting SO2 measurement and quantitative characterization of device performance. The flow system is comprised of a peristaltic pump, membrane oxygenator, oxygen and nitrogen gas, and in-line oxygen, pH, and temperature sensors that enable real-time estimation of SO2 reference values. Bovine blood was delivered through breast-relevant tissue phantoms containing vessel-mimicking fluid channels, which were imaged using a custom multispectral PAI system. Blood was periodically drawn for SO2 measurement in a clinical-grade CO-oximeter. We used this flow phantom system to evaluate the impact of device parameters (e.g.,wavelength-dependent fluence corrections) and tissue parameters (e.g. fluid channel depth, blood SO2, spectral coloring artifacts) on oximetry measurement accuracy. Results elucidated key challenges in PAI oximetry and device design trade-offs, which subsequently allowed for optimization of system performance. This approach provides a robust benchtop test platform that can support PAI oximetry device optimization, performance validation, and clinical translation, and may inform future development of consensus test methods for performance assessment of photoacoustic oximetry imaging systems.

  13. Role of blood culture systems in the evaluation of epidemiological features of coagulase-negative staphylococcal bloodstream infection in critically ill patients.

    Science.gov (United States)

    Oud, L; Krimerman, S; Salam, N; Srugo, I

    1999-12-01

    The impact of blood culture systems on the detection of coagulase-negative staphylococcal bloodstream infections in critically ill patients prior to and following the introduction of the Bactec 9240 blood culture system (Becton Dickinson Diagnostic Instrument Systems, USA), which replaced the Bactec NR 730 (Becton Dickinson Diagnostic Instrument Systems), was investigated over a 3-year period. Following the introduction of the new culture system, the incidence of bloodstream infections doubled (P<0.001). Patient demographics, severity of illness, and mortality remained unchanged, while the annual standardized mortality ratio decreased significantly. These data suggest that blood culture systems may have a major impact on the perceived incidence of coagulase-negative staphylococcal bloodstream infections in this population.

  14. Blood donors and factors impacting the blood donation decision: motives for donating blood in Turkish sample.

    Science.gov (United States)

    Karacan, Eda; Cengiz Seval, Guldane; Aktan, Zeynep; Ayli, Meltem; Palabiyikoglu, Refia

    2013-12-01

    Donations in Turkey are insufficient to cover the high transfusion needs arising from large numbers of thalassemia and sickle cell anemia patients and increasing demands for blood due to advanced surgery and cancer treatment. The most acceptable means to get blood is voluntary blood donation and the blood donor system in Turkey mostly depends on a combination of voluntary and involuntary donors. The main aim of this study is to explore the motivations of Turkish voluntary blood donors toward blood donation and to determine predictors of blood donation motivation. A cross-sectional sample survey of active blood donors in Ankara, Turkey was conducted. The sample consisted of 189 male volunteer blood donor adults. Donors filled in a self-administered questionnaire including the measures of demographic information, empathetic concern, altruism, social responsibility and blood donation motivation questionnaire during donation. Factor analysis of Blood Donation Motivation Measure with varimax rotation revealed a three-factor solution named as "values and moral duty", "positive feelings and esteem" and "self-benefit and external reasons". The results with regression analyses showed that only social responsibility had an significant effect independent of age, income, and education on blood donation motivation. These result reflects that blood donation motivation not only linked to a high degree of altruistic reasons, but also to a combination of some self-regarding motives. Additionally, feelings of empathy or altruism may be less strong at the time the decision to help, other factors may have a larger influence on helping decisions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Identification of blood culture isolates directly from positive blood cultures by use of matrix-assisted laser desorption ionization-time of flight mass spectrometry and a commercial extraction system: analysis of performance, cost, and turnaround time.

    Science.gov (United States)

    Lagacé-Wiens, Philippe R S; Adam, Heather J; Karlowsky, James A; Nichol, Kimberly A; Pang, Paulette F; Guenther, Jodi; Webb, Amanda A; Miller, Crystal; Alfa, Michelle J

    2012-10-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsityper) for use with the Bruker MALDI BioTyper has facilitated the processing required for identification of pathogens directly from positive from blood cultures. We report the results of an evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species. The Bruker MALDI BioTyper with the Sepsityper gave a valid (score, >1.7) identification for 85.2% of positive blood cultures with no misidentifications. The mean reduction in turnaround time to identification was 34.3 h (P MALDI-TOF was used for all blood cultures and 26.5 h in a more practical setting where conventional identification or identification from subcultures was required for isolates that could not be directly identified by MALDI-TOF. Implementation of a MALDI-TOF-based identification system for direct identification of pathogens from blood cultures is expected to be associated with a marginal increase in operating costs for most laboratories. However, the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.

  16. Blood irradiation: Rationale and technique

    International Nuclear Information System (INIS)

    Lewis, M.C.

    1990-01-01

    Upon request by the local American Red Cross, the Savannah Regional Center for Cancer Care irradiates whole blood or blood components to prevent post-transfusion graft-versus-host reaction in patients who have severely depressed immune systems. The rationale for blood irradiation, the total absorbed dose, the type of patients who require irradiated blood, and the regulations that apply to irradiated blood are presented. A method of irradiating blood using a linear accelerator is described

  17. Changes in blood lead levels associated with use of chloramines in water treatment systems.

    Science.gov (United States)

    Miranda, Marie Lynn; Kim, Dohyeong; Hull, Andrew P; Paul, Christopher J; Galeano, M Alicia Overstreet

    2007-02-01

    More municipal water treatment plants are using chloramines as a disinfectant in order to reduce carcinogenic by-products. In some instances, this has coincided with an increase in lead levels in drinking water in those systems. Lead in drinking water can be a significant health risk. We sought to test the potential effect of switching to chloramines for disinfection in water treatment systems on childhood blood lead levels using data from Wayne County, located in the central Coastal Plain of North Carolina. We constructed a unified geographic information system (GIS) that links blood lead screening data with age of housing, drinking water source, and census data for 7,270 records. The data were analyzed using both exploratory methods and more formal multivariate techniques. The analysis indicates that the change to chloramine disinfection may lead to an increase in blood lead levels, the impact of which is progressively mitigated in newer housing. Introducing chloramines to reduce carcinogenic by-products may increase exposure to lead in drinking water. Our research provides guidance on adjustments in the local childhood lead poisoning prevention program that should accompany changes in water treatment. As similar research is conducted in other areas, and the underlying environmental chemistry is clarified, water treatment strategies can be optimized across the multiple objectives that municipalities face in providing high quality drinking water to local residents.

  18. [Application of multiplex PCR for the screening of genotyping system for the rare blood groups Fy(a-), s-,k-,Di(b-) and Js(b-)].

    Science.gov (United States)

    Jiao, Wei; Xie, Li; Li, Hailan; Lan, Jiao; Mo, Zhuning; Yang, Ziji; Liu, Fei; Xiao, Ruiping; He, Yunlei; Ye, Luyi; Zhu, Ziyan

    2014-04-01

    To screen rare blood groups Fy(a-), s-, k-, Di(b-) and Js(b-) in an ethnic Zhuang population. Sequence-specific primers were designed based on single nucleotide polymorphism (SNP) sites of blood group antigens Fy(b) and s. A specific multiplex PCR system I was established. Multiplex PCR system II was applied to detect alleles antigens Di(b), k, Js(b)1910 and Js(b) 2019 at the same time. The two systems was were used to screen for rare blood group antigens in 4490 randomly selected healthy donors of Guangxi Zhuang ethnic origin. We successfully made the multiplex PCR system I. We detected the rare blood group antigens using the two PCR system. There are five Fy(a-), three s(-), two Di(b-) in 4490 Guangxi zhuang random samples. The multiplex PCR system I has achieved good accuracy and stability. With multiplex PCR systems I and II, 4490 samples were screened. Five Fy(a-), three s(-) and two Di(b-) samples were discovered. Multiplex PCR is an effective methods, which can be used for high throughput screening of rare blood groups. The rare blood types of Guangxi Zhuang ethnic origin obtained through the screening can provide valuable information for compatible blood transfusion. Through screening we obtained precious rare blood type materials which can be used to improve the capability of compatible infusion and reduce the transfusion reactions.

  19. Multimodal in vivo blood flow sensing combining particle image velocimetry and optical tweezers-based blood steering

    Science.gov (United States)

    Meissner, Robert; Sugden, Wade W.; Siekmann, Arndt F.; Denz, Cornelia

    2018-02-01

    All higher developed organisms contain complex hierarchical networks of arteries, veins and capillaries. These constitute the cardiovascular system responsible for supplying nutrients, gas and waste exchange. Diseases related to the cardiovascular system are among the main causes for death worldwide. In order to understand the processes leading to arteriovenous malformation, we studied hereditary hemorrhagic telangiectasia (HHT), which has a prevalence of 1:5000 worldwide and causes internal bleeding. In zebrafish, HHT is induced by mutation of the endoglin gene involved in HHT and observed to reduce red blood cell (RBC) flow to intersegmental vessels (ISVs) in the tail due to malformations of the dorsal aorta (DA) and posterior cardinal vein (PCV). However, these capillaries are still functional. Changes in the blood flow pattern are observed from in vivo data from zebrafish embryos through particle image velocimetry (PIV). Wall shear rates (WSRs) and blood flow velocities are obtained non-invasively with millisecond resolution. We observe significant increases of blood flow velocity in the DA for endoglin-deficient zebrafish embryos (mutants) at 3 days post fertilization. In the PCV, this increase is even more pronounced. We identified an increased similarity between the DA and the PCV of mutant fish compared to siblings, i.e., unaffected fish. To counteract the reduced RBC flow to ISVs we implement optical tweezers (OT). RBCs are steered into previously unperfused ISVs showing a significant increase of RBC count per minute. We discuss limitations with respect to biocompatibility of optical tweezers in vivo and determination of in vivo wall shear stress (WSS) connected to normal and endoglin-deficicent zebrafish embryos.

  20. Can mHealth improve access to safe blood for transfusion during obstetric emergency?

    Directory of Open Access Journals (Sweden)

    Rahman A

    2017-04-01

    Full Text Available Aminur Rahman,1,2 Sadika Akhter,1 Monjura Khatun Nisha,3 Syed Shariful Islam,4 Fatema Ashraf,5 Monjur Rahman,1 Nazneen Begum,6 Mahbub Elahi Chowdhury,1 Anne Austin,7 Iqbal Anwar1 1International Centre for Diarrhoeal Disease Research, Bangladesh (icddr,b, Dhaka, Bangladesh; 2College of Public Health Sciences, Chulalongkorn University, Bangkok, Thailand; 3Sydney School of Public Health, Sydney Medical School, The University of Sydney, Sydney, NSW, Australia; 4Department of Public Health and Informatics, Bangabandhu Sheikh Mujib Medical University, 5Department of Gyenaecology and Obstetric, Shaheed Suhrawardi Medical College and Hospital, 6Department of Gyenaecology and Obstetric, Dhaka Medical College and Hospital, Dhaka, Bangladesh; 7JSI Research & Training Institute, Inc., Boston, MA, USA Purpose: Of the 99% maternal deaths that take place in developing countries, one-fourth is due to postpartum hemorrhage (PPH. PPH accounts for one-third of all blood transfusions in Bangladesh where the transfusion process is lengthy as most facilities do not have in-house blood bank facilities. In this context, the location where blood is obtained and the processes of obtaining blood products are not standardized, leading to preventable delays in collecting blood, when it is needed. This study evaluated the effectiveness of an online Blood Information Management Application (BIMA system for reducing lag time in the blood transfusion process.Patients and methods: The study was conducted in a public medical college hospital in Dhaka, Bangladesh, and in two proximate, licensed blood banks between January 2014 and March 2015, using a before after design. A total of 310 women (143 before and 177 after, who needed emergency blood transfusion during their perinatal period, as determined by a medical professional, were included in the study. A median linear regression model was employed to assess the adjusted effect of BIMA on transfusion time.Results: After the

  1. Simple tube centrifugation for processing platelet-rich plasma in the horse.

    Science.gov (United States)

    Fontenot, Robin L; Sink, Carolyn A; Werre, Stephen R; Weinstein, Nicole M; Dahlgren, Linda A

    2012-12-01

    This study evaluated the quality and bacteriologic safety of platelet-rich plasma (PRP) produced by 3 simple, inexpensive tube centrifugation methods and a commercial system. Citrated equine blood collected from 26 normal horses was processed by 4 methods: blood collection tubes centrifuged at 1200 and 2000 × g, 50-mL conical tube, and a commercial system. White blood cell (WBC), red blood cell (RBC), and platelet counts and mean platelet volume (MPV) were determined for whole blood and PRP, and aerobic and anaerobic cultures were performed. Mean platelet concentrations ranged from 1.55- to 2.58-fold. The conical method yielded the most samples with platelet concentrations greater than 2.5-fold and within the clinically acceptable range of > 250,000 platelets/μL. White blood cell counts were lowest with the commercial system and unacceptably high with the blood collection tubes. The conical tube method may offer an economically feasible and comparatively safe alternative to commercial PRP production systems.

  2. Blood irradiation

    International Nuclear Information System (INIS)

    Chandy, Mammen

    1998-01-01

    Viable lymphocytes are present in blood and cellular blood components used for transfusion. If the patient who receives a blood transfusion is immunocompetent these lymphocytes are destroyed immediately. However if the patient is immunodefficient or immunosuppressed the transfused lymphocytes survive, recognize the recipient as foreign and react producing a devastating and most often fatal syndrome of transfusion graft versus host disease [T-GVHD]. Even immunocompetent individuals can develop T-GVHD if the donor is a first degree relative since like the Trojan horse the transfused lymphocytes escape detection by the recipient's immune system, multiply and attack recipient tissues. T-GVHD can be prevented by irradiating the blood and different centers use doses ranging from 1.5 to 4.5 Gy. All transfusions where the donor is a first degree relative and transfusions to neonates, immunosuppressed patients and bone marrow transplant recipients need to be irradiated. Commercial irradiators specifically designed for irradiation of blood and cellular blood components are available: however they are expensive. India needs to have blood irradiation facilities available in all large tertiary institutions where immunosuppressed patients are treated. The Atomic Energy Commission of India needs to develop a blood irradiator which meets international standards for use in tertiary medical institutions in the country. (author)

  3. The applying of multisensory system to assessment of blood samples by composition of equilibrium gaseous phase

    Directory of Open Access Journals (Sweden)

    T. A. Kuchmenko

    2013-01-01

    Full Text Available In the article discussed the possibility of blood sample’s assessment with the following diagnostic characteristics: "endometriosis", "fibroids", "uterine body cancer" by the signals of multisensor system. It has been found that blood samples can be reliably ranking into groups according to their diagnostic characteristics using the geometry, square of "visual prints" and the sorption effectiveness parameters max ij А.

  4. Relative Risks of Thrombosis and Bleeding in Different ABO Blood Groups.

    Science.gov (United States)

    Franchini, Massimo; Lippi, Giuseppe

    2016-03-01

    The ABO blood group system is composed of complex carbohydrate molecules (i.e., the A, B, and H determinants) that are widely expressed on the surface of red blood cells and in a variety of other cell and tissues. Along with their pivotal role in transfusion and transplantation medicine, the ABO antigens participate in many other physiological processes and, in particular, are important determinants of von Willebrand factor and factor VIII circulating plasma levels. The precise influence of the ABO system on hemostasis has led the way to the investigation of a putative implication in the risk of developing cardiovascular disorders. Along with the underlying molecular mechanisms, the current knowledge on the role of ABO blood group antigens in both the thrombotic and hemorrhagic risk will be summarized in this narrative review. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Rotating permanent magnet excitation for blood flow measurement.

    Science.gov (United States)

    Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S

    2015-11-01

    A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

  6. Using Process Mining to Learn from Process Changes in Evolutionary Systems

    NARCIS (Netherlands)

    Günther, Christian W.; Rinderle, S.B.; Reichert, M.U.; van der Aalst, Wil M.P.; Recker, Jan

    2008-01-01

    Traditional information systems struggle with the requirement to provide flexibility and process support while still enforcing some degree of control. Accordingly, adaptive process management systems (PMSs) have emerged that provide some flexibility by enabling dynamic process changes during

  7. Astrocytic TYMP and VEGFA drive blood-brain barrier opening in inflammatory central nervous system lesions.

    Science.gov (United States)

    Chapouly, Candice; Tadesse Argaw, Azeb; Horng, Sam; Castro, Kamilah; Zhang, Jingya; Asp, Linnea; Loo, Hannah; Laitman, Benjamin M; Mariani, John N; Straus Farber, Rebecca; Zaslavsky, Elena; Nudelman, German; Raine, Cedric S; John, Gareth R

    2015-06-01

    In inflammatory central nervous system conditions such as multiple sclerosis, breakdown of the blood-brain barrier is a key event in lesion pathogenesis, predisposing to oedema, excitotoxicity, and ingress of plasma proteins and inflammatory cells. Recently, we showed that reactive astrocytes drive blood-brain barrier opening, via production of vascular endothelial growth factor A (VEGFA). Here, we now identify thymidine phosphorylase (TYMP; previously known as endothelial cell growth factor 1, ECGF1) as a second key astrocyte-derived permeability factor, which interacts with VEGFA to induce blood-brain barrier disruption. The two are co-induced NFκB1-dependently in human astrocytes by the cytokine interleukin 1 beta (IL1B), and inactivation of Vegfa in vivo potentiates TYMP induction. In human central nervous system microvascular endothelial cells, VEGFA and the TYMP product 2-deoxy-d-ribose cooperatively repress tight junction proteins, driving permeability. Notably, this response represents part of a wider pattern of endothelial plasticity: 2-deoxy-d-ribose and VEGFA produce transcriptional programs encompassing angiogenic and permeability genes, and together regulate a third unique cohort. Functionally, each promotes proliferation and viability, and they cooperatively drive motility and angiogenesis. Importantly, introduction of either into mouse cortex promotes blood-brain barrier breakdown, and together they induce severe barrier disruption. In the multiple sclerosis model experimental autoimmune encephalitis, TYMP and VEGFA co-localize to reactive astrocytes, and correlate with blood-brain barrier permeability. Critically, blockade of either reduces neurologic deficit, blood-brain barrier disruption and pathology, and inhibiting both in combination enhances tissue preservation. Suggesting importance in human disease, TYMP and VEGFA both localize to reactive astrocytes in multiple sclerosis lesion samples. Collectively, these data identify TYMP as an

  8. Molecular – genetic variance of RH blood group system within human population of Bosnia and Herzegovina

    Directory of Open Access Journals (Sweden)

    Lejla Lasić

    2013-02-01

    Full Text Available There are two major theories for inheritance of Rh blood group system: Fisher - Race theory and Wiener theory. Aim of this study was identifying frequency of RHDCE alleles in Bosnian - Herzegovinian population and introduction of this method in screening for Rh phenotype in B&H since this type of analysis was not used for blood typing in B&H before. Rh blood group was typed by Polymerase Chain Reaction, using the protocols and primers previously established by other authors, then carrying out electrophoresis in 2-3% agarose gel. Percentage of Rh positive individuals in our sample is 84.48%, while the percentage of Rh negative individuals is 15.52%. Inter-rater agreement statistic showed perfect agreement (K=1 between the results of Rh blood system detection based on serological and molecular-genetics methods. In conclusion, molecular - genetic methods are suitable for prenatal genotyping and specific cases while standard serological method is suitable for high-throughput of samples.

  9. Data processing system for NBT experiments

    International Nuclear Information System (INIS)

    Takahashi, C.; Hosokawa, M.; Shoji, T.; Fujiwara, M.

    1981-07-01

    Data processing system for Nagoya Bumpy Torus (NBT) has been developed. Since plasmas are produced and heated in steady state by use of high power microwaves, sampling and processing data prevails in long time scale on the order of one minute. The system, which consists of NOVA 3/12 minicomputer and many data acquisition devices, is designed to sample and process large amount of data before the next discharge starts. Several features of such long time scale data processing system are described in detail. (author)

  10. Process control using modern systems of information processing

    International Nuclear Information System (INIS)

    Baldeweg, F.

    1984-01-01

    Modern digital automation techniques allow the application of demanding types of process control. These types of process control are characterized by their belonging to higher levels in a multilevel model. Functional and technical aspects of the performance of digital automation plants are presented and explained. A modern automation system is described considering special procedures of process control (e.g. real time diagnosis)

  11. Intraoperative evaluation of renal blood flow during laparoscopic partial nephrectomy with a novel Doppler system.

    Science.gov (United States)

    Mues, Adam C; Okhunov, Zhamshid; Badani, Ketan; Gupta, Mantu; Landman, Jaime

    2010-12-01

    Hemostasis remains a major challenge associated with laparoscopic renal surgery. We evaluated a cost-effective novel Doppler probe (DP) for assessment of vascular control during laparoscopic partial nephrectomy (LPN). We prospectively collected data during LPN procedures. We documented tumor location and size as well as subjective quality of the hilar dissection. The DP was compared with our standard intraoperative ultrasound system (SUS) for the ability to detect blood flow during hilar dissection and to determine parenchymal ischemia around the tumor after clamping of the renal vessels. Twenty patients underwent LPN by a single surgeon. The mean tumor size was 3.0 cm (range: 1.2-6.3 cm). The times to assess the kidney using the SUS and DP were 68.6 seconds (range: 20-155) and 44.5 seconds (range: 15-180), respectively. Evaluation prior to renal hilar clamping demonstrated the presence of blood flow in all 20 patients (100%) using the SUS and in 17 of 20 (85%) using the DP. Similarly, cessation of blood flow with clamping was documented in 100% of cases with SUS and 85% with DP. Persistent flow was detected by both SUS and DP in two patients requiring further dissection and reclamping. Then, both systems detected the absence of flow before tumor resection. With blood flow interruption confirmation, no patient had significant bleeding at the time of renal parenchymal transection. Intraoperative Doppler ultrasound technologies minimize the risk of significant bleeding during LPN. The DP is a small, simple, effective probe that can be used to assess blood flow interruption to the kidney during laparoscopic renal surgery.

  12. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    Science.gov (United States)

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  13. Systemic chemotherapy induces microsatellite instability in the peripheral blood mononuclear cells of breast cancer patients

    International Nuclear Information System (INIS)

    Fonseca, Fernando LA; Sant Ana, Aleksandra VL; Bendit, Israel; Arias, Vitor; Costa, Luciano J; Pinhal, Aparecida A; Giglio, Auro del

    2005-01-01

    Systemic chemotherapy is an important part of treatment for breast cancer. We conducted the present study to evaluate whether systemic chemotherapy could produce microsatellite instability (MSI) in the peripheral blood mononuclear cell fraction of breast cancer patients. We studied 119 sequential blood samples from 30 previously untreated breast cancer patients before, during and after chemotherapy. For comparison, we also evaluated 20 women who had no relevant medical history (control group). In 27 out of 30 patients we observed MSI in at least one sample, and six patients had loss of heterozygosity. We found a significant correlation between the number of MSI events per sample and chemotherapy with alkylating agents (P < 0.0001). We also observed an inverse correlation between the percentage of cells positive for hMSH2 and the number of MSI events per sample (P = 0.00019) and use of alkylating agents (P = 0.019). We conclude that systemic chemotherapy may induce MSI and loss of heterozygosity in peripheral blood mononuclear cells from breast cancer patients receiving alkylating agents, possibly mediated by a chemotherapy-induced decrease in the expression of hMSH2. These effects may be related to the generation of secondary leukaemia in some patients, and may also intensify the genetic instability of tumours and increase resistance to treatment

  14. Recycled incomplete identification procedures for blood screening

    NARCIS (Netherlands)

    Bar-Lev, S.K.; Boxma, O.J.; Kleiner, I.; Perry, D.; Stadje, W.

    2017-01-01

    The operation of blood banks aims at the cost-efficient supply of uncontaminated human blood. Each unit of donated blood goes through multiple testing for the presence of various pathogens which are able to cause transfusion-transmitted diseases. The blood screening process is comprised of two

  15. Morphology and physiology of the olfactory system of blood-feeding insects.

    Science.gov (United States)

    Guidobaldi, F; May-Concha, I J; Guerenstein, P G

    2014-01-01

    Several blood-feeding (hematophagous) insects are vectors of a number of diseases including dengue, Chagas disease and leishmaniasis which persistently affect public health throughout Latin America. The vectors of those diseases include mosquitoes, triatomine bugs and sandflies. As vector control is an efficient way to prevent these illnesses it is important to understand the sensory biology of those harmful insects. We study the physiology of the olfactory system of those insects and apply that knowledge on the development of methods to manipulate their behavior. Here we review some of the latest information on insect olfaction with emphasis on hematophagous insects. The insect olfactory sensory neurons are housed inside hair-like organs called sensilla which are mainly distributed on the antenna and mouthparts. The identity of many of the odor compounds that those neurons detect are already known in hematophagous insects. They include several constituents of host (vertebrate) odor, sex, aggregation and alarm pheromones, and compounds related to egg-deposition behavior. Recent work has contributed significant knowledge on how odor information is processed in the insect first odor-processing center in the brain, the antennal lobe. The quality, quantity, and temporal features of the odor stimuli are encoded by the neural networks of the antennal lobe. Information regarding odor mixtures is also encoded. While natural mixtures evoke strong responses, synthetic mixtures that deviate from their natural counterparts in terms of key constituents or proportions of those constituents evoke weaker responses. The processing of olfactory information is largely unexplored in hematophagous insects. However, many aspects of their olfactory behavior are known. As in other insects, responses to relevant single odor compounds are weak while natural mixtures evoke strong responses. Future challenges include studying how information about odor mixtures is processed in their brain

  16. Multielement surface plasmon resonance immunosensor for monitoring of blood circulation system

    Science.gov (United States)

    Kostyukevych, Sergey A.; Kostyukevych, Kateryna V.; Khristosenko, Roman V.; Lysiuk, Viktor O.; Koptyukh, Anastasiya A.; Moscalenko, Nadiya L.

    2017-12-01

    The problems related to the development of a multielement immunosensor device with the prism type of excitation of a surface plasmon resonance in the Kretschmann configuration and with the scanning of the incidence angle of monochromatic light aimed at the reliable determination of the levels of three molecular markers of the system of hemostasis (fibrinogen, soluble fibrin, and D-dimer) are considered. We have analyzed the influence of a technology for the production of a gold coating, modification of its surface, and noise effects on the enhancement of sensitivity and stability of the operation of devices. A means of oriented immobilization of monoclonal antibodies on the surface of gold using a multilayer film of copper aminopentacyanoferrate is developed. For the model proteins of studied markers, the calibrating curves (maximum sensitivity of 0.5 μg/ml) are obtained, and the level of fibrinogen in blood plasma of donors is determined. A four-channel modification of the device with an application of a reference channel for comparing the elimination of the noise of temperature fluctuations has been constructed. This device allows one to execute the express-diagnostics of prethrombotic states and the monitoring of the therapy of diseases of the blood circulation system.

  17. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  18. Characterization of 3D PET systems for accurate quantification of myocardial blood flow

    OpenAIRE

    Renaud, Jennifer M.; Yip, Kathy; Guimond, Jean; Trottier, Mikaël; Pibarot, Philippe; Turcotte, Éric; Maguire, Conor; Lalonde, Lucille; Gulenchyn, Karen; Farncombe, Troy; Wisenberg, Gerald; Moody, Jonathan; Lee, Benjamin; Port, Steven C.; Turkington, Timothy G

    2016-01-01

    Three-dimensional (3D) mode imaging is the current standard for positron emission tomography-computed tomography (PET-CT) systems. Dynamic imaging for quantification of myocardial blood flow (MBF) with short-lived tracers, such as Rb-82- chloride (Rb-82), requires accuracy to be maintained over a wide range of isotope activities and scanner count-rates. We propose new performance standard measurements to characterize the dynamic range of PET systems for accurate quantitative...

  19. Periodontal disease level-butyric acid amounts locally administered in the rat gingival mucosa induce ER stress in the systemic blood.

    Science.gov (United States)

    Cueno, Marni E; Saito, Yuko; Ochiai, Kuniyasu

    2016-05-01

    Periodontal diseases have long been postulated to contribute to systemic diseases and, likewise, it has been proposed that periodontal disease treatment may ameliorate certain systemic diseases. Short-chain fatty acids (SCFA) are major secondary metabolites produced by oral anaerobic bacteria and, among the SCFAs, butyric acid (BA) in high amounts contribute to periodontal disease development. Periodontal disease level-butyric acid (PDL-BA) is found among patients suffering from periodontal disease and has previously shown to induce oxidative stress, whereas, oxidative stress is correlated to endoplasmic reticulum (ER) stress. This would imply that PDL-BA may likewise stimulate ER stress, however, this was never elucidated. A better understanding of the correlation between PDL-BA and systemic ER stress stimulation could shed light on the possible systemic effects of PDL-BA-related periodontal diseases. Here, PDL-BA was injected into the gingival mucosa and the systemic blood obtained from the rat jugular was collected at 0, 15, 60, and 180 min post-injection. Collected blood samples were purified and only the blood cytosol was used throughout this study. Subsequently, we measured blood cytosolic GADD153, Ca(2+), representative apoptotic and inflammatory caspases, and NF-κB amounts. We found that PDL-BA presence increased blood cytosolic GADD153 and Ca(2+) amounts. Moreover, we observed that blood cytosolic caspases and NF-κB were activated only at 60 and 180 min post-injection in the rat gingival mucosa. This suggests that PDL-BA administered through the gingival mucosa may influence the systemic blood via ER stress stimulation and, moreover, prolonged PDL-BA retention in the gingival mucosa may play a significant role in ER stress-related caspase and NF-κB activation. In a periodontal disease scenario, we propose that PDL-BA-related ER stress stimulation leading to the simultaneous activation of apoptosis and inflammation may contribute to periodontal disease

  20. Power processing systems for ion thrusters.

    Science.gov (United States)

    Herron, B. G.; Garth, D. R.; Finke, R. C.; Shumaker, H. A.

    1972-01-01

    The proposed use of ion thrusters to fulfill various communication satellite propulsion functions such as east-west and north-south stationkeeping, attitude control, station relocation and orbit raising, naturally leads to the requirement for lightweight, efficient and reliable thruster power processing systems. Collectively, the propulsion requirements dictate a wide range of thruster power levels and operational lifetimes, which must be matched by the power processing. This paper will discuss the status of such power processing systems, present system design alternatives and project expected near future power system performance.

  1. Three-dimensional imaging of absolute blood flow velocity and blood vessel position under low blood flow velocity based on Doppler signal information included in scattered light from red blood cells

    Science.gov (United States)

    Kyoden, Tomoaki; Akiguchi, Shunsuke; Tajiri, Tomoki; Andoh, Tsugunobu; Hachiga, Tadashi

    2017-11-01

    The development of a system for in vivo visualization of occluded distal blood vessels for diabetic patients is the main target of our research. We herein describe two-beam multipoint laser Doppler velocimetry (MLDV), which measures the instantaneous multipoint flow velocity and can be used to observe the blood flow velocity in peripheral blood vessels. By including a motorized stage to shift the measurement points horizontally and in the depth direction while measuring the velocity, the path of the blood vessel in the skin could be observed using blood flow velocity in three-dimensional space. The relationship of the signal power density between the blood vessel and the surrounding tissues was shown and helped us identify the position of the blood vessel. Two-beam MLDV can be used to simultaneously determine the absolute blood flow velocity distribution and identify the blood vessel position in skin.

  2. Profiles of blood and blood component transfusion recipients in Zimbabwe

    Science.gov (United States)

    Mafirakureva, Nyashadzaishe; Khoza, Star; Hassall, Oliver; Faragher, Brian E.; Kajja, Isaac; Mvere, David A.; Emmanuel, Jean C.; Postma, Maarten J.; van Hulst, Marinus

    2015-01-01

    Background There are limited published data on the characteristics of blood transfusion recipients in sub-Saharan Africa. This study describes the demographic characteristics of blood transfusion recipients and patterns of blood and blood component use in Zimbabwe. Materials and methods Data on the characteristics of the blood transfusion recipients (age, sex, blood group), blood components received (type, quantity), discharge diagnoses and outcomes following transfusion (discharge status, duration of stay in hospital), were retrospectively collected from four major hospitals for the period from January 1, 2012 to December 31, 2012. Diagnoses were grouped into broad categories according to the disease headings of the International Classification of Diseases (ICD-10). Surgical procedures were grouped into broad categories according to organ system using ICD-9. Results Most of the 1,793 transfusion recipients studied were female (63.2%) and in the reproductive age group, i.e. 15–49 years (65.3%). The median age of the recipients was 33 years (range, 0–93). The majority of these recipients (n=1,642; 91.6%) received a red blood cell transfusion. The majority of the patients were diagnosed with conditions related to pregnancy and childbirth (22.3%), and diseases of blood and blood-forming organs (17.7%). The median time spent in hospital was 8 days (range, 0–214) and in-hospital mortality was 15.4%. Discussion Our sample of blood transfusion recipients were fairly young and most of them received red blood cell transfusions. The majority of patients in the reproductive age group received blood transfusions for pregnancy and childbirth-related diagnoses. PMID:26192782

  3. Social network supported process recommender system.

    Science.gov (United States)

    Ye, Yanming; Yin, Jianwei; Xu, Yueshen

    2014-01-01

    Process recommendation technologies have gained more and more attention in the field of intelligent business process modeling to assist the process modeling. However, most of the existing technologies only use the process structure analysis and do not take the social features of processes into account, while the process modeling is complex and comprehensive in most situations. This paper studies the feasibility of social network research technologies on process recommendation and builds a social network system of processes based on the features similarities. Then, three process matching degree measurements are presented and the system implementation is discussed subsequently. Finally, experimental evaluations and future works are introduced.

  4. Social Network Supported Process Recommender System

    Directory of Open Access Journals (Sweden)

    Yanming Ye

    2014-01-01

    Full Text Available Process recommendation technologies have gained more and more attention in the field of intelligent business process modeling to assist the process modeling. However, most of the existing technologies only use the process structure analysis and do not take the social features of processes into account, while the process modeling is complex and comprehensive in most situations. This paper studies the feasibility of social network research technologies on process recommendation and builds a social network system of processes based on the features similarities. Then, three process matching degree measurements are presented and the system implementation is discussed subsequently. Finally, experimental evaluations and future works are introduced.

  5. The Physics of Coronary Blood Flow

    CERN Document Server

    Zamir, M

    2005-01-01

    Coronary blood flow is blood flow to the heart for its own metabolic needs. In the most common form of heart disease there is a disruption in this flow because of obstructive disease in the vessels that carry the flow. The subject of coronary blood flow is therefore associated mostly with the pathophysiology of this disease, rarely with dynamics or physics. Yet, the system responsible for coronary blood flow, namely the "coronary circulation," is a highly sophisticated dynamical system in which the dynamics and physics of the flow are as important as the integrity of the conducting vessels. While an obstruction in the conducting vessels is a fairly obvious and clearly visible cause of disruption in coronary blood flow, any discord in the complex dynamics of the system can cause an equally grave, though less conspicuous, disruption in the flow. This book is devoted specifically to the dynamics and physics of coronary blood flow. While relevance to the clinical and pathophysiological issues is clearly maintaine...

  6. Segmentation of white blood cells and comparison of cell morphology by linear and naïve Bayes classifiers.

    Science.gov (United States)

    Prinyakupt, Jaroonrut; Pluempitiwiriyawej, Charnchai

    2015-06-30

    Blood smear microscopic images are routinely investigated by haematologists to diagnose most blood diseases. However, the task is quite tedious and time consuming. An automatic detection and classification of white blood cells within such images can accelerate the process tremendously. In this paper we propose a system to locate white blood cells within microscopic blood smear images, segment them into nucleus and cytoplasm regions, extract suitable features and finally, classify them into five types: basophil, eosinophil, neutrophil, lymphocyte and monocyte. Two sets of blood smear images were used in this study's experiments. Dataset 1, collected from Rangsit University, were normal peripheral blood slides under light microscope with 100× magnification; 555 images with 601 white blood cells were captured by a Nikon DS-Fi2 high-definition color camera and saved in JPG format of size 960 × 1,280 pixels at 15 pixels per 1 μm resolution. In dataset 2, 477 cropped white blood cell images were downloaded from CellaVision.com. They are in JPG format of size 360 × 363 pixels. The resolution is estimated to be 10 pixels per 1 μm. The proposed system comprises a pre-processing step, nucleus segmentation, cell segmentation, feature extraction, feature selection and classification. The main concept of the segmentation algorithm employed uses white blood cell's morphological properties and the calibrated size of a real cell relative to image resolution. The segmentation process combined thresholding, morphological operation and ellipse curve fitting. Consequently, several features were extracted from the segmented nucleus and cytoplasm regions. Prominent features were then chosen by a greedy search algorithm called sequential forward selection. Finally, with a set of selected prominent features, both linear and naïve Bayes classifiers were applied for performance comparison. This system was tested on normal peripheral blood smear slide images from two datasets. Two sets

  7. The Blood Stocks Management Scheme, a partnership venture between the National Blood Service of England and North Wales and participating hospitals for maximizing blood supply chain management.

    Science.gov (United States)

    Chapman, J F; Cook, R

    2002-10-01

    The Blood Stocks Management Scheme (BSMS) has been established as a joint venture between the National Blood Service (NBS) in England and North Wales and participating hospitals to monitor the blood supply chain. Stock and wastage data are submitted to a web-based data-management system, facilitating continuous and complete red cell data collection and 'real time' data extraction. The data-management system enables peer review of performance in respect of stock holding levels and red cell wastage. The BSMS has developed an innovative web-based data-management system that enables data collection and benchmarking of practice, which should drive changes in stock management practice, therefore optimizing the use of donated blood.

  8. Information Processing Capacity of Dynamical Systems

    Science.gov (United States)

    Dambre, Joni; Verstraeten, David; Schrauwen, Benjamin; Massar, Serge

    2012-07-01

    Many dynamical systems, both natural and artificial, are stimulated by time dependent external signals, somehow processing the information contained therein. We demonstrate how to quantify the different modes in which information can be processed by such systems and combine them to define the computational capacity of a dynamical system. This is bounded by the number of linearly independent state variables of the dynamical system, equaling it if the system obeys the fading memory condition. It can be interpreted as the total number of linearly independent functions of its stimuli the system can compute. Our theory combines concepts from machine learning (reservoir computing), system modeling, stochastic processes, and functional analysis. We illustrate our theory by numerical simulations for the logistic map, a recurrent neural network, and a two-dimensional reaction diffusion system, uncovering universal trade-offs between the non-linearity of the computation and the system's short-term memory.

  9. Information Processing Capacity of Dynamical Systems

    Science.gov (United States)

    Dambre, Joni; Verstraeten, David; Schrauwen, Benjamin; Massar, Serge

    2012-01-01

    Many dynamical systems, both natural and artificial, are stimulated by time dependent external signals, somehow processing the information contained therein. We demonstrate how to quantify the different modes in which information can be processed by such systems and combine them to define the computational capacity of a dynamical system. This is bounded by the number of linearly independent state variables of the dynamical system, equaling it if the system obeys the fading memory condition. It can be interpreted as the total number of linearly independent functions of its stimuli the system can compute. Our theory combines concepts from machine learning (reservoir computing), system modeling, stochastic processes, and functional analysis. We illustrate our theory by numerical simulations for the logistic map, a recurrent neural network, and a two-dimensional reaction diffusion system, uncovering universal trade-offs between the non-linearity of the computation and the system's short-term memory. PMID:22816038

  10. Direct blood culturing on solid medium outperforms an automated continuously monitored broth-based blood culture system in terms of time to identification and susceptibility testing

    Directory of Open Access Journals (Sweden)

    E.A. Idelevich

    2016-03-01

    Full Text Available Pathogen identification and antimicrobial susceptibility testing (AST should be available as soon as possible for patients with bloodstream infections. We investigated whether a lysis-centrifugation (LC blood culture (BC method, combined with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS identification and Vitek 2 AST, provides a time advantage in comparison with the currently used automated broth-based BC system. Seven bacterial reference strains were added each to 10 mL human blood in final concentrations of 100, 10 and 1 CFU/mL. Inoculated blood was added to the Isolator 10 tube and centrifuged at 3000 g for 30 min, then 1.5 mL sediment was distributed onto five 150-mm agar plates. Growth was observed hourly and microcolonies were subjected to MALDI-TOF MS and Vitek 2 as soon as possible. For comparison, seeded blood was introduced into an aerobic BC bottle and incubated in the BACTEC 9240 automated BC system. For all species/concentration combinations except one, successful identification and Vitek 2 inoculation were achieved even before growth detection by BACTEC. The fastest identification and inoculation for AST were achieved with Escherichia coli in concentrations of 100 CFU/mL and 10 CFU/mL (after 7 h each, while BACTEC flagged respective samples positive after 9.5 h and 10 h. Use of the LC-BC method allows skipping of incubation in automated BC systems and, used in combination with rapid diagnostics from microcolonies, provides a considerable advantage in time to result. This suggests that the usefulness of direct BC on solid medium should be re-evaluated in the era of rapid microbiology.

  11. Can sibutramine alter systemic blood pressure in obese patients? Systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Hernani Pinto de Lemos Júnior

    Full Text Available CONTEXT: Systemic arterial hypertension is part of the metabolic syndrome resulting from obesity. OBJECTIVE: To evaluate the effect of sibutramine on overweight and obese patients' blood pressure through a systematic review. METHODS: All the studies included needed to be randomized controlled trials. The methodological quality of the selected trials was assessed using the criteria described in the Cochrane Handbook. The participants were overweight and obese patients; the intervention was sibutramine compared with placebo. The primary outcome measurement was systolic and diastolic blood pressure and the secondary measurement was blood pressure. Studies were identified by searching the following sources: Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs, Medline, Cochrane reviews, manual searches, personal communication and contact with the pharmaceutical industry. There were no language, date or other restrictions. Data collection and extraction was performed by two reviewers, who independently obtained the full articles of all eligible papers. RESULTS: Three meta-analyses were produced: 1 systolic blood pressure outcome (eight studies did not show statistical significance between sibutramine and placebo: weighted mean difference (WMD 1.57, confidence interval (CI -0.03 to 3.18; 2 diastolic blood pressure outcome (ten studies did not show statistical significance between sibutramine and placebo: WMD 1.13, CI -0.49 to 2.76; 3 blood pressure outcome (two studies also did not show statistical significance between the groups: relative risk (RR 0.69, CI 0.07 to 7.01. CONCLUSIONS: The meta-analyses presented in this systematic review show that sibutramine does not have a statistically significant effect on blood pressure, compared with placebo.

  12. Information processing systems, reasoning modules, and reasoning system design methods

    Science.gov (United States)

    Hohimer, Ryan E; Greitzer, Frank L; Hampton, Shawn D

    2014-03-04

    Information processing systems, reasoning modules, and reasoning system design methods are described. According to one aspect, an information processing system includes working memory comprising a semantic graph which comprises a plurality of abstractions, wherein the abstractions individually include an individual which is defined according to an ontology and a reasoning system comprising a plurality of reasoning modules which are configured to process different abstractions of the semantic graph, wherein a first of the reasoning modules is configured to process a plurality of abstractions which include individuals of a first classification type of the ontology and a second of the reasoning modules is configured to process a plurality of abstractions which include individuals of a second classification type of the ontology, wherein the first and second classification types are different.

  13. Information processing systems, reasoning modules, and reasoning system design methods

    Energy Technology Data Exchange (ETDEWEB)

    Hohimer, Ryan E.; Greitzer, Frank L.; Hampton, Shawn D.

    2016-08-23

    Information processing systems, reasoning modules, and reasoning system design methods are described. According to one aspect, an information processing system includes working memory comprising a semantic graph which comprises a plurality of abstractions, wherein the abstractions individually include an individual which is defined according to an ontology and a reasoning system comprising a plurality of reasoning modules which are configured to process different abstractions of the semantic graph, wherein a first of the reasoning modules is configured to process a plurality of abstractions which include individuals of a first classification type of the ontology and a second of the reasoning modules is configured to process a plurality of abstractions which include individuals of a second classification type of the ontology, wherein the first and second classification types are different.

  14. Information processing systems, reasoning modules, and reasoning system design methods

    Energy Technology Data Exchange (ETDEWEB)

    Hohimer, Ryan E.; Greitzer, Frank L.; Hampton, Shawn D.

    2015-08-18

    Information processing systems, reasoning modules, and reasoning system design methods are described. According to one aspect, an information processing system includes working memory comprising a semantic graph which comprises a plurality of abstractions, wherein the abstractions individually include an individual which is defined according to an ontology and a reasoning system comprising a plurality of reasoning modules which are configured to process different abstractions of the semantic graph, wherein a first of the reasoning modules is configured to process a plurality of abstractions which include individuals of a first classification type of the ontology and a second of the reasoning modules is configured to process a plurality of abstractions which include individuals of a second classification type of the ontology, wherein the first and second classification types are different.

  15. On Distributed Port-Hamiltonian Process Systems

    NARCIS (Netherlands)

    Lopezlena, Ricardo; Scherpen, Jacquelien M.A.

    2004-01-01

    In this paper we use the term distributed port-Hamiltonian Process Systems (DPHPS) to refer to the result of merging the theory of distributed Port-Hamiltonian systems (DPHS) with the theory of process systems (PS). Such concept is useful for combining the systematic interconnection of PHS with the

  16. Progress in the blood supply of Afghanistan.

    Science.gov (United States)

    Riley, William J; McCullough, Terri Konstenius; Rhamani, Ahmad Masoud; McCullough, Jeffrey

    2017-07-01

    The blood supply system in Afghanistan was badly damaged by years of conflict. In 2009, the Afghanistan National Blood Safety and Transfusion Service (ANBSTS) was established. For 6 years, we collaborated to assist with policy and infrastructure development; blood bank operations; blood collection, testing, and component production; transfusion practices; and training of technicians, nurses, midwives, and physicians. Policies were established, infrastructure was strengthened, and capable staff was acquired and trained. Standard operating procedures were developed, testing was improved, and quality systems were established. Thirty trainings were held for blood center staff. Four additional formal trainings were held for 39 physicians, 36 nurses and/or midwives, and 38 laboratory technicians. During 5 years of this project, blood collection increased by 40%. The ANBSTS has made impressive progress developing infrastructure, personnel, procedures, quality systems, and training programs and increasing blood collection. Knowledge of transfusion medicine was improved through structured training. © 2017 AABB.

  17. Gaming the System: Developing an Educational Game for Securing Principles of Arterial Blood Gases.

    Science.gov (United States)

    Boyd, Cory Ann; Warren, Jonah; Glendon, Mary Ann

    2016-01-01

    This article describes the development process for creating a digital educational mini game prototype designed to provide practice opportunities for learning fundamental principles of arterial blood gases. Mini games generally take less than an hour to play and focus on specific subject matter. An interdisciplinary team of faculty from two universities mentored student game developers to design a digital educational mini game prototype. Sixteen accelerated bachelor of science in nursing students collaborated with game development students and playtested the game prototype during the last semester of their senior year in nursing school. Playtesting is a form of feedback that supports an iterative design process that is critical to game development. A 10-question survey was coupled with group discussions addressing five broad themes of an archetypical digital educational mini game to yield feedback on game design, play, and content. Four rounds of playtesting and incorporating feedback supported the iterative process. Accelerated bachelor of science in nursing student playtester feedback suggests that the digital educational mini game prototype has potential for offering an engaging, playful game experience that will support securing the fundamental principles of arterial blood gases. Next steps are to test the digital educational mini game for teaching and learning effectiveness. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Self-separation of blood plasma from whole blood during the capillary flow in microchannel

    Science.gov (United States)

    Nunna, Bharath Babu; Zhuang, Shiqiang; Lee, Eon Soo

    2017-11-01

    Self-separation of blood plasma from whole blood in microchannels is of great importance due to the enormous range of applications in healthcare and diagnostics. Blood is a multiphase complex fluid, composed of cells suspended in blood plasma. RBCs are the suspended particles whose shape changes during the flow of blood. The primary constituents of blood are erythrocytes or red blood cells (RBCs), leukocytes or white blood cells (WBCs), thrombocytes or platelets and blood plasma. The existence of RBCs in blood makes the blood a non-Newtonian fluid. The current study of separation of blood plasma from whole blood during self-driven flows in a single microchannel without bifurcation, by enhancing the capillary effects. The change in the capillary effect results in a change in contact angle which directly influences the capillary flow. The flow velocity directly influences the net force acting on the RBCs and influence the separation process. The experiments are performed on the PDMS microchannels with different contact angles by altering the surface characteristics using plasma treatment. The change in the separation length is studied during the capillary flow of blood in microchannel. Bharath Babu Nunna is a researcher in mechanical engineering and implementing the novel and innovative technologies in the biomedical devices to enhance the sensitivity of the disease diagnosis.

  19. Next generation of non-mammalian blood-brain barrier models to study parasitic infections of the central nervous system

    OpenAIRE

    Siddiqui, Ruqaiyyah; Edwards-Smallbone, James; Flynn, Robin; Khan, Naveed Ahmed

    2012-01-01

    Transmigration of neuropathogens across the blood-brain barrier is a key step in the development of central nervous system infections, making it a prime target for drug development. The ability of neuropathogens to traverse the blood-brain barrier continues to inspire researchers to understand the specific strategies and molecular mechanisms that allow them to enter the brain. The availability of models of the blood-brain barrier that closely mimic the situation in vivo offers unprecedented o...

  20. Implementing SLMTA in the Kenya National Blood Transfusion Service: lessons learned

    Directory of Open Access Journals (Sweden)

    Eric N. Wakaria

    2017-04-01

    Full Text Available Background: The Kenya National Blood Transfusion Service (KNBTS is mandated to provide safe and sufficient blood and blood components for the country. In 2013, the KNBTS National Testing Laboratory and the six regional blood transfusion centres were enrolled in the Strengthening Laboratory Management Toward Accreditation (SLMTA programme. The process was supported by Global Communities with funding from the United States Centers for Disease Control and Prevention. Methods: The SLMTA implementation at KNBTS followed the standard three-workshop series, on-site mentorships and audits. Baseline, midterm and exit audits were conducted at the seven facilities, using a standard checklist to measure progress. Given that SLMTA was designed for clinical and public health laboratories, key stakeholders, guided by Global Communities, tailored SLMTA materials to address blood transfusion services, and oriented trainers, auditors and mentors on the same. Results: The seven facilities moved from an average of zero stars at baseline to an average of three stars at the exit audit. The average baseline audit score was 38% (97 points, midterm 71% (183 points and exit audit 79% (205 points. The Occurrence Management and Process Improvement quality system essential had the largest improvement (at 67 percentage points, from baseline to exit, whereas Facilities and Safety had the smallest improvement (at 31 percentage points. Conclusion: SLMTA can be an effective tool for preparing a blood transfusion service for accreditation. Key success factors included customising SLMTA to blood transfusion activities; sensitising trainers, mentors and auditors on operations of blood transfusion service; creating SLMTA champions in key departments; and integrating other blood transfusion-specific accreditation standards into SLMTA.

  1. [Automated management of the Center of Transfusion Blood Bank equipped with Autogrouper 16 C].

    Science.gov (United States)

    Girard, M; Connes, Y; Picot, P

    1981-11-01

    We describe in this paper a first processing of direct connection and data management from the Autogrouper 16 C. It bas been used since November 1980 in the Centre Départemental de Tranfusion Sanguine des Hauts-de-Seine. The automation of validation procedures, updating blood donors' file and labelling blood units allows the suppression of clerical errors that are the major cause of Trannsfusion accidents. The progressive development of programming lets a good adaptation of working methods and makes the setting of the system much easier in the Blood Bank.

  2. Application of forensic luminol for blood detection in endodontic files

    Directory of Open Access Journals (Sweden)

    Rodrigo ARRUDA-VASCONCELOS

    Full Text Available Abstract Introduction Blood is a biological material with high potential of infectious transmission in dental environments, including herpes simplex, hepatitis and AIDS. Aim To investigate the efficacy of luminol in detecting blood in endodontic files before and after the sterilization process. Material and method Luminol was used to investigate the presence or absence of traces of blood tissue in 50 endodontic files, visible to naked eye or not, after performing endodontic treatment and after the cleaning/sterilization process. The results obtained were tabulated and statistically analyzed by using the Friedman’s test at a significance level of 5% (p<0.05. Result By naked eye, it was found that 31/50 files showed no trace of blood, 8/50 showed a slight presence of blood and 11/50 showed a considerable presence of blood after endodontic treatment. After the use of luminol, however, 16/50 endodontic files showed no trace of blood, 19/50 showed a slight presence of blood and 15/50 showed a considerable presence of blood. After the cleaning and sterilization process, no blood was detected in the files. Conclusion It was concluded that the luminol solution is effective in detecting blood tissue in endodontic files as well as in validating the cleaning/sterilization process.

  3. Does dysfunction of the autonomic nervous system affect success of renal denervation in reducing blood pressure?

    Science.gov (United States)

    Fricke, Lisa; Petroff, David; Desch, Steffen; Lurz, Philipp; Reinhardt, Sebastian; Sonnabend, Melanie; Classen, Joseph; Baum, Petra

    2017-01-01

    Renal denervation is an interventional approach aiming to reduce high blood pressure. Its efficacy is subject of controversial debate. We analyzed autonomic function in patients undergoing renal denervation to identify responders. A total of 21 patients with treatment-resistant hypertension scheduled for renal denervation were included. Heart rate variability, pupillary function and sympathetic skin response were examined prior to intervention. Before and 1 or 3 months after intervention, 24-h ambulatory blood pressure readings were taken. Patients were stratified according to sympathetic nervous system function. Sympathetic activity was reduced in 12 participants (group 1) and normal or enhanced in nine patients (group 2). The mean of daytime systolic blood pressure decreased in groups 1 and 2 from 168 to 157 mmHg (95% confidence interval for difference, 1-21 mmHg, p = 0.035) and from 166 to 145 mmHg (8-34 mmHg, p = 0.005), respectively. In a linear model, blood pressure reduction was 11.3 mmHg (0.3-22 mmHg) greater in group 2 than in group 1 (p = 0.045). Patients with preexisting reduced activity of the sympathetic nervous system benefited less from renal denervation.

  4. Does dysfunction of the autonomic nervous system affect success of renal denervation in reducing blood pressure?

    Directory of Open Access Journals (Sweden)

    Lisa Fricke

    2017-04-01

    Full Text Available Objectives: Renal denervation is an interventional approach aiming to reduce high blood pressure. Its efficacy is subject of controversial debate. We analyzed autonomic function in patients undergoing renal denervation to identify responders. Methods: A total of 21 patients with treatment-resistant hypertension scheduled for renal denervation were included. Heart rate variability, pupillary function and sympathetic skin response were examined prior to intervention. Before and 1 or 3 months after intervention, 24-h ambulatory blood pressure readings were taken. Results: Patients were stratified according to sympathetic nervous system function. Sympathetic activity was reduced in 12 participants (group 1 and normal or enhanced in nine patients (group 2. The mean of daytime systolic blood pressure decreased in groups 1 and 2 from 168 to 157 mmHg (95% confidence interval for difference, 1–21 mmHg, p = 0.035 and from 166 to 145 mmHg (8–34 mmHg, p = 0.005, respectively. In a linear model, blood pressure reduction was 11.3 mmHg (0.3–22 mmHg greater in group 2 than in group 1 (p = 0.045. Conclusion: Patients with preexisting reduced activity of the sympathetic nervous system benefited less from renal denervation.

  5. Chlorinated Flavonoids Modulate the Inflammatory Process in Human Blood.

    Science.gov (United States)

    Proença, Carina; Ribeiro, Daniela; Soares, Tânia; Tomé, Sara M; Silva, Artur M S; Lima, José L F C; Fernandes, Eduarda; Freitas, Marisa

    2017-08-01

    Flavonoids are known to react with neutrophil-generated hypochlorous acid (HOCl) at inflammation loci to form stable mono- and dichlorinated products. Some of these products have been shown to retain or even enhance their inflammatory potential, but further information is required in a broader approach to inflammatory mechanisms. In that sense, we performed an integrated evaluation on the anti-inflammatory potential of a panel of novel chlorinated flavonoids and their parent compounds, in several steps of the complex inflammatory cascade, namely, in the activity of cyclooxygenase (COX)-1 and COX-2, and in the production of cytokines [interleukin (IL)-6, IL-1β, tumor necrosis factor (TNF)], and the chemokine, IL-8, as well as in the production of reactive species, using human whole blood as a representative in vitro model, establishing, whenever possible, a structure-activity relationship. Although luteolin was the most active compound, chlorinated flavonoids demonstrated a remarkable pattern of activity for the resolution of the inflammatory processes. Our results demonstrated that 6-chloro-3',4',5,7-tetrahydroxyflavone deserves scientific attention due to its ability to modulate the reactive species and cytokines/chemokine production. In this regard, the therapeutic potential of flavonoids' metabolites, and in this particular case the chlorinated flavonoids, should not be neglected.

  6. Proposing a Process-Oriented Systems Research for Systems Thinking Development

    Directory of Open Access Journals (Sweden)

    Jae Eon Yu

    2017-04-01

    Full Text Available This paper discusses systems thinking development from Churchman’s systems ideas related to critical systems practice that appreciates the use of systems methods from sociolinguistic perspectives and poststructuralist thought. Systems research enabled us to understand and reinterpret Churchman’s philosophy and systems approach through the works of Deleuze and Foucault. Based upon the interpretation of Churchman’s philosophy and systems approach, I propose ‘process-oriented systems research’ developed from the use of social appreciative process and Churchman’s metasystem approach. By applying a metasystem approach into practice, I basically appreciate Deleuzian ethics and Foucault’s theory of discourse in order to deal with issues of power and knowledge, and metaethics or moral epistemology, where the meaning of good or bad is discussed. A detailed account of an application of process-oriented systems research is given to demonstrate how I use systems methods to examine the usefulness of the systems research in practice.

  7. Microfluidic Devices for Blood Fractionation

    OpenAIRE

    Hou, Han Wei; Bhagat, Ali Asgar S.; Lee, Wong Cheng J.; Huang, Sha; Han, Jongyoon; Lim, Chwee Teck

    2011-01-01

    Blood, a complex biological fluid, comprises 45% cellular components suspended in protein rich plasma. These different hematologic components perform distinct functions in vivo and thus the ability to efficiently fractionate blood into its individual components has innumerable applications in both clinical diagnosis and biological research. Yet, processing blood is not trivial. In the past decade, a flurry of new microfluidic based technologies has emerged to address this compelling problem. ...

  8. Legal and ethical issues in safe blood transfusion

    Directory of Open Access Journals (Sweden)

    Shivaram Chandrashekar

    2014-01-01

    Full Text Available Legal issues play a vital role in providing a framework for the Indian blood transfusion service (BTS, while ethical issues pave the way for quality. Despite licensing of all blood banks, failure to revamp the Drugs and Cosmetic Act (D and C Act is impeding quality. Newer techniques like chemiluminescence or nucleic acid testing (NAT find no mention in the D and C Act. Specialised products like pooled platelet concentrates or modified whole blood, therapeutic procedures like erythropheresis, plasma exchange, stem cell collection and processing technologies like leukoreduction and irradiation are not a part of the D and C Act. A highly fragmented BTS comprising of over 2500 blood banks, coupled with a slow and tedious process of dual licensing (state and centre is a hindrance to smooth functioning of blood banks. Small size of blood banks compromises blood safety. New blood banks are opened in India by hospitals to meet requirements of insurance providers or by medical colleges as this a Medical Council of India (MCI requirement. Hospital based blood banks opt for replacement donation as they are barred by law from holding camps. Demand for fresh blood, lack of components, and lack of guidelines for safe transfusion leads to continued abuse of blood. Differential pricing of blood components is difficult to explain scientifically or ethically. Accreditation of blood banks along with establishment of regional testing centres could pave the way to blood safety. National Aids Control Organisation (NACO and National Blood Transfusion Council (NBTC deserve a more proactive role in the licensing process. The Food and Drug Administration (FDA needs to clarify that procedures or tests meant for enhancement of blood safety are not illegal.

  9. [European Union and blood transfusion].

    Science.gov (United States)

    Rouger, P

    2003-06-01

    Blood transfusion is progressing, Europe is growing, European blood transfusion organisations are developing rapidly. The first step was the publication of a new directive (2002/98/CE). The directive is the result of a compromise between technocracy, lobbying and blood transfusion professionals. European blood transfusion must be based on medical, scientific and social criteria. Two imperatives must be considered: the respect of ethics and; independence from the commercial system. The primary objective is to give satisfaction to patients while respecting blood donors.

  10. Discrepancy in abo blood grouping

    International Nuclear Information System (INIS)

    Khan, M.N.; Ahmed, Z.; Khan, T.A.

    2013-01-01

    Discrepancies in blood typing is one of the major reasons in eliciting a transfusion reaction. These discrepancies can be avoided through detailed analysis for the blood typing. Here, we report a subgroup of blood group type-B in the ABO system. Donor's blood was analyzed by employing commercial antisera for blood grouping. The results of forward (known antisera) and reverse (known antigen) reaction were not complimentary. A detailed analysis using the standard protocols by American Association of Blood Banking revealed the blood type as a variant of blood group-B instead of blood group-O. This is suggestive of the fact that blood group typing should be performed with extreme care and any divergence, if identified, should be properly resolved to avoid transfusion reactions. Moreover, a major study to determine the blood group variants in Pakistani population is needed. (author)

  11. A data driven nonlinear stochastic model for blood glucose dynamics.

    Science.gov (United States)

    Zhang, Yan; Holt, Tim A; Khovanova, Natalia

    2016-03-01

    The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  12. The Diabetes Assistant: A Smartphone-Based System for Real-Time Control of Blood Glucose

    Directory of Open Access Journals (Sweden)

    Patrick Keith-Hynes

    2014-11-01

    Full Text Available Type 1 Diabetes Mellitus (T1DM is an autoimmune disease in which the insulin-producing beta cells of the pancreas are destroyed and insulin must be injected daily to enable the body to metabolize glucose. Standard therapy for T1DM involves self-monitoring of blood glucose (SMBG several times daily with a blood glucose meter and injecting insulin via a syringe, pen or insulin pump. An “Artificial Pancreas” (AP is a closed-loop control system that uses a continuous glucose monitor (CGM, an insulin pump and an internal algorithm to automatically manage insulin infusion to keep the subject’s blood glucose within a desired range. Although no fully closed-loop AP systems are currently commercially available there are intense academic and commercial efforts to produce safe and effective AP systems. In this paper we present the Diabetes Assistant (DiAs, an ultraportable AP research platform designed to enable home studies of Closed Loop Control (CLC of blood glucose in subjects with Type 1 Diabetes Mellitus. DiAs consists of an Android (Google Inc., Mountain View, CA, USA smartphone equipped with communication, control and user interface software wirelessly connected to a continuous glucose monitor and insulin pump. The software consists of a network of mobile applications with well-defined Application Programming Interfaces (APIs running atop an enhanced version of Android with non-essential elements removed. CLC and safety applications receive real-time data from the CGM and pump, estimate the patient’s metabolic state and risk of hypo- and hyperglycemia, adjust the insulin infusion rate, raise alarms as needed and transmit de-identified data to a secure remote server. Some applications may be replaced by researchers wishing to conduct outpatient ambulatory studies of novel Closed Loop Control, Safety or User Interface modules. Over the past three years the DiAs platform has been used in a series of AP clinical trials sponsored by the National

  13. Histopathological Study of Central Nervous System Lesions: Emphasizing Association of Neoplasms with ABO Blood Groups.

    Science.gov (United States)

    Kumarguru, B N; Pallavi, P; Sunila; Manjunath, G V; Vasan, T S; Rajalakshmi, B R

    2017-04-01

    The Central Nervous System (CNS) lesions show considerable geographic and racial variations with respect to the incidence and the pattern of distribution of lesions. The ABO blood status is a readily accessible factor in genetic constitution of the patients. It has been shown to be associated with many diseases. But the influence of blood group status on the pathogenesis of brain tumours is still unclear. To study various histopathological patterns of CNS lesions and to evaluate the association of CNS tumours with the distribution of ABO blood groups in documented cases. In the present study, 147 cases were analyzed. It was an analytical type of study, done at JSS Medical College, Mysore, over a period of 2 years and 8 months from January 2009 to August 2011. Histopathology slides were routinely stained by Haematoxylin and Eosin (H&E) stain. Special stains were performed in selected cases. Blood group of the patients and the control group were documented. Blood group distribution pattern was assessed in relation to histopathological diagnosis of various CNS tumours. Histopathological diagnosis of 147 cases included neoplastic lesions (84.35%) and non-neoplastic lesions (15.64%). Neoplastic lesions (84.35%) constituted the majority, which included neuroepithelial tumours (29.25%) as predominant pattern. Non-neoplastic lesions constituted only 15.64%, which included inflammatory lesion (8.16%) as the predominant pattern. ABO blood group data was available in 92 cases (84.4%) of neoplastic lesions, which included 71 cases (48.29%) of primary CNS neoplasms categorized according to WHO grades. The control group constituted 21,067 healthy voluntary donors. Blood group O was the most frequent blood group in neoplastic lesions (40.21%) and primary CNS neoplasms categorized according to WHO grades (45.07%). The association between the CNS neoplasms and ABO blood groups was not statistically significant (p = 0.055). But a definite change in the pattern of distribution of ABO

  14. Design of penicillin fermentation process simulation system

    Science.gov (United States)

    Qi, Xiaoyu; Yuan, Zhonghu; Qi, Xiaoxuan; Zhang, Wenqi

    2011-10-01

    Real-time monitoring for batch process attracts increasing attention. It can ensure safety and provide products with consistent quality. The design of simulation system of batch process fault diagnosis is of great significance. In this paper, penicillin fermentation, a typical non-linear, dynamic, multi-stage batch production process, is taken as the research object. A visual human-machine interactive simulation software system based on Windows operation system is developed. The simulation system can provide an effective platform for the research of batch process fault diagnosis.

  15. The effect of three different doses of tranexamic acid on blood loss after cardiac surgery with mild systemic hypothermia (32 degrees C).

    Science.gov (United States)

    Karski, J M; Dowd, N P; Joiner, R; Carroll, J; Peniston, C; Bailey, K; Glynn, M F; Teasdale, S J; Cheng, D C

    1998-12-01

    Prophylactic administration of tranexamic acid (TA), an antifibrinolytic agent, decreases bleeding after cardiac surgery with systemic hypothermia (25 degrees C to 29 degrees C). Warmer systemic temperatures during cardiopulmonary bypass (CPB) may reduce bleeding and thus alter the requirement for TA. The effect of three different doses of TA on bleeding after cardiac surgery with mild systemic hypothermia (32 degrees C) is evaluated. Double-blind, prospective, randomized study. University hospital. One hundred fifty adult patients undergoing aortocoronary bypass or valvular cardiac surgery. Patients received TA, 50 (n = 50), 100 (n = 50), or 150 (n = 50) mg/kg intravenously before CPB with mild systemic hypothermia. Blood loss through chest drains over 6, 12, and 24 hours after surgery and total hemoglobin loss were measured. Autotransfused blood, transfused banked blood and blood products, and coagulation profiles were measured. Analysis of variance on log-transformed data for blood loss and confidence intervals (CIs) of 0.95 were calculated and transformed to milliliters of blood. No patient was re-explored for bleeding. Blood loss at 6 hours was statistically greater in the 50-mg/kg group compared with the other two groups (p = 0.03; p = 0.02). Total hemoglobin loss was statistically greater in the 50-mg/kg group compared with the 150-mg/kg group (p = 0.04). There was no statistical difference in blood tranfusion rate or coagulation profiles among the three groups. However, preoperative hemoglobin level was statistically lower in the 150-mg/kg group compared with the other two groups (p = 0.01). Of the three doses of TA studied, the most efficacious and cost-effective dose to reduce bleeding after cardiac surgery with mild hypothermic systemic perfusion is 100 mg/kg.

  16. Peripheral blood aspirates overexpressing IGF-I via rAAV gene transfer undergo enhanced chondrogenic differentiation processes.

    Science.gov (United States)

    Frisch, Janina; Orth, Patrick; Rey-Rico, Ana; Venkatesan, Jagadeesh Kumar; Schmitt, Gertrud; Madry, Henning; Kohn, Dieter; Cucchiarini, Magali

    2017-11-01

    Implantation of peripheral blood aspirates induced towards chondrogenic differentiation upon genetic modification in sites of articular cartilage injury may represent a powerful strategy to enhance cartilage repair. Such a single-step approach may be less invasive than procedures based on the use of isolated or concentrated MSCs, simplifying translational protocols in patients. In this study, we provide evidence showing the feasibility of overexpressing the mitogenic and pro-anabolic insulin-like growth factor I (IGF-I) in human peripheral blood aspirates via rAAV-mediated gene transfer, leading to enhanced proliferative and chondrogenic differentiation (proteoglycans, type-II collagen, SOX9) activities in the samples relative to control (reporter rAAV-lacZ) treatment over extended periods of time (at least 21 days, the longest time-point evaluated). Interestingly, IGF-I gene transfer also triggered hypertrophic, osteo- and adipogenic differentiation processes in the aspirates, suggesting that careful regulation of IGF-I expression may be necessary to contain these events in vivo. Still, the current results demonstrate the potential of targeting human peripheral blood aspirates via therapeutic rAAV transduction as a novel, convenient tool to treat articular cartilage injuries. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  17. Maternal systemic or cord blood inflammation is associated with birth anthropometry in a Tanzanian prospective cohort.

    Science.gov (United States)

    Wilkinson, A L; Pedersen, S H; Urassa, M; Michael, D; Andreasen, A; Todd, J; Kinung'hi, S M; Changalucha, J; McDermid, J M

    2017-01-01

    HIV infection is associated with chronic systemic inflammation, with or without antiretroviral therapy. Consequences for foetal growth are not understood, particularly in settings where multiple maternal infections and malnutrition are common. The study was designed to examine maternal systemic circulating and umbilical cord blood cytokine concentrations in relation to birth anthropometry in a Tanzanian prospective cohort. A 9-plex panel of maternal plasma cytokines in HIV-positive (n = 44) and HIV-negative (n = 70) mothers and the same cytokines in umbilical cord blood collected at delivery was assayed. Linear regression modelled associations between maternal or cord blood cytokines and birth anthropometry. Health indicators (haemoglobin, mid-upper-arm circumference, body mass index) in HIV-positive mothers without considerable immunosuppression did not differ from HIV-negative women. Despite this, HIV-exposed infants had lower birthweight and length. Subgroup analyses indicated that HIV management using HAART was associated with lower plasma TNF-α, as were longer durations of any antiretroviral therapy (≥2 months). Greater maternal plasma TNF-α was associated with earlier delivery (-1.7 weeks, P = 0.039) and lower birthweights (-287 g; P = 0.020), while greater umbilical cord TNF-α (-1.43 cm; P = 0.036) and IL-12p70 (-2.4 cm; P = 0.008) were associated with shorter birth length. Birthweight was inversely associated with cord IL-12p70 (-723 g; P = 0.001) and IFN-γ (-482 g, P = 0.007). Maternal cytokines during pregnancy did not correlate with umbilical cord cytokines at delivery. Systemic inflammation identified in maternal plasma or umbilical cord blood was associated with poorer birth anthropometrics in HIV-exposed and HIV-unexposed infants. Controlling maternal and/or foetal systemic inflammation may improve birth anthropometry. © 2016 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  18. Algorithm for detection of overlapped red blood cells in microscopic images of blood smears

    OpenAIRE

    Romero-Rondón, Miguel Fabián; Sanabria-Rosas, Laura Melissa; Bautista-Rozo, Lola Xiomara; Mendoza-Castellanos, Alfonso

    2016-01-01

    The hemogram is one of the most requested medical tests as it presents details about the three cell series in the blood: red series, white series and platelet series. To make some diagnostics, the specialist must undertake the test manually, observing the blood cells under the microscope, which implies a great physical effort. In order to facilitate this work, different digital image processing techniques to detect and classify red blood cells have been proposed. However, a common problem is ...

  19. Process fluid cooling system

    International Nuclear Information System (INIS)

    Farquhar, N.G.; Schwab, J.A.

    1977-01-01

    A system of heat exchangers is disclosed for cooling process fluids. The system is particularly applicable to cooling steam generator blowdown fluid in a nuclear plant prior to chemical purification of the fluid in which it minimizes the potential of boiling of the plant cooling water which cools the blowdown fluid

  20. Process gas solidification system

    International Nuclear Information System (INIS)

    1980-01-01

    A process for withdrawing gaseous UF 6 from a first system and directing same into a second system for converting the gas to liquid UF 6 at an elevated temperature, additionally including the step of withdrawing the resulting liquid UF 6 from the second system, subjecting it to a specified sequence of flash-evaporation, cooling and solidification operations, and storing it as a solid in a plurality of storage vessels. (author)

  1. The leech nervous system: a valuable model to study the microglia involvement in regenerative processes.

    Science.gov (United States)

    Le Marrec-Croq, Françoise; Drago, Francesco; Vizioli, Jacopo; Sautière, Pierre-Eric; Lefebvre, Christophe

    2013-01-01

    Microglia are intrinsic components of the central nervous system (CNS). During pathologies in mammals, inflammatory processes implicate the resident microglia and the infiltration of blood cells including macrophages. Functions of microglia appear to be complex as they exhibit both neuroprotective and neurotoxic effects during neuropathological conditions in vivo and in vitro. The medicinal leech Hirudo medicinalis is a well-known model in neurobiology due to its ability to naturally repair its CNS following injury. Considering the low infiltration of blood cells in this process, the leech CNS is studied to specify the activation mechanisms of only resident microglial cells. The microglia recruitment is known to be essential for the usual sprouting of injured axons and does not require any other glial cells. The present review will describe the questions which are addressed to understand the nerve repair. They will discuss the implication of leech factors in the microglial accumulation, the identification of nerve cells producing these molecules, and the study of different microglial subsets. Those questions aim to better understand the mechanisms of microglial cell recruitment and their crosstalk with damaged neurons. The study of this dialog is necessary to elucidate the balance of the inflammation leading to the leech CNS repair.

  2. The Leech Nervous System: A Valuable Model to Study the Microglia Involvement in Regenerative Processes

    Directory of Open Access Journals (Sweden)

    Françoise Le Marrec-Croq

    2013-01-01

    Full Text Available Microglia are intrinsic components of the central nervous system (CNS. During pathologies in mammals, inflammatory processes implicate the resident microglia and the infiltration of blood cells including macrophages. Functions of microglia appear to be complex as they exhibit both neuroprotective and neurotoxic effects during neuropathological conditions in vivo and in vitro. The medicinal leech Hirudo medicinalis is a well-known model in neurobiology due to its ability to naturally repair its CNS following injury. Considering the low infiltration of blood cells in this process, the leech CNS is studied to specify the activation mechanisms of only resident microglial cells. The microglia recruitment is known to be essential for the usual sprouting of injured axons and does not require any other glial cells. The present review will describe the questions which are addressed to understand the nerve repair. They will discuss the implication of leech factors in the microglial accumulation, the identification of nerve cells producing these molecules, and the study of different microglial subsets. Those questions aim to better understand the mechanisms of microglial cell recruitment and their crosstalk with damaged neurons. The study of this dialog is necessary to elucidate the balance of the inflammation leading to the leech CNS repair.

  3. Development of blood irradiators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is designed to improve the techniques of blood irradiation through the development of improved and portable blood irradiators. A portable blood irradiator, consisting of a vitreous carbon body and thulium-170 radiation source, was attached to dogs via a carotid-jugular shunt, and its effects on the immune system measured. The device has demonstrated both significant suppression of circulating lymphocytes and prolonged retention of skin allografts

  4. Lactate versus pH levels in fetal scalp blood during labor--using the Lactate Scout System

    DEFF Research Database (Denmark)

    Lundin, Ingeborg Christina Rørbye; Perslev, Anette; Nickelsen, Carsten Nahne Amtoft

    2016-01-01

    OBJECTIVE: To assess if lactate measured with the Scout Lactate System is a reliable alternative to pH in intrapartum monitoring of the fetus. METHODS: A prospective study analyzing (1) the correlation between scalp lactate measured by the Scout Lactate System and the Automatic Blood Laboratory (...

  5. The Blood-Brain Barrier: An Engineering Perspective

    Directory of Open Access Journals (Sweden)

    Andrew eWong

    2013-08-01

    Full Text Available It has been more than 100 years since Paul Ehrlich reported that various water-soluble dyes injected into the circulation did not enter the brain. Since Ehrlich’s first experiments, only a small number of molecules, such as alcohol and caffeine have been found to cross the blood-brain barrier, and it remains the major roadblock to treatment of many central nervous system diseases. At the same time, many central nervous system diseases are associated with disruption of the blood-brain barrier that can lead to changes in permeability, modulation of immune cell transport, and trafficking of pathogens into the brain. Therefore advances in our understanding of the structure and function of the blood-brain barrier are key to advances in treatment of a wide range of central nervous system diseases. Over the past 10 years it has become recognized that the blood-brain barrier is a complex dynamic system that involves biomechanical and biochemical signaling between the vascular system and the brain. Here we reconstruct the structure, function, and transport properties of the blood-brain barrier from an engineering perspective. New insight into the physics of the blood-brain barrier could ultimately lead to clinical advances in the treatment of central nervous system diseases.

  6. The polymorphism of the Knops blood group system among five Chinese ethnic groups.

    Science.gov (United States)

    Li, Qin; Han, Sha-Sha; Guo, Zhong-Hui; Yang, Ying; Zhou, Jie; Zhu, Zi-Yan

    2010-12-01

    This work aims to explain the complexity of the Knops blood group system in the Chinese population. The Knops blood group system consists of antigens encoded by CR1 gene exon 29. A total of 281 individuals from the Han, Uigur, Tu, Lisu and Dong ethnic groups were studied. The coding region of the CR1 gene of 11 Han donors was analysed using reverse transcription-polymerase chain reaction (PCR) and sequencing. CR1 gene exon 29 in the 39 samples was analysed through genomic DNA sequencing. According to the sequencing result, a PCR-sequence-specific primers system was designed to screen the A4646G and A4870G alleles in the Chinese population. Twelve single nucleotide polymorphisms (SNPs) were observed in the coding region of the CR1 gene in the Han population. Two SNPs (A4646G and A4870G) were detected in the CR1 gene exon 29. The 4646G allele was found only in the Uigur and Tu ethnic groups, in which the allele frequencies were 0·11 and 0·06, respectively. The frequencies of the 4870A allele in the Han, Uigur, Tu, Lisu and Dong ethnic groups were 0·82, 0·83, 0·82, 0·57 and 0·57, respectively. The CR1 gene in the Chinese people is more conservative than that in the Caucasian or African people. Different Chinese ethnic groups may have their own different CR1 gene characteristics. The existence of 4646G in the Uigur and Tu ethnic groups suggests that both may carry certain Caucasian characteristics in the CR1 gene. The frequency of 4870G in the Lisu and Dong ethnic groups implies possible incidence of evolutionary pressure similar to what the Africans had experienced. © 2010 The Authors. Transfusion Medicine © 2010 British Blood Transfusion Society.

  7. Process fault diagnosis using knowledge-based systems

    International Nuclear Information System (INIS)

    Sudduth, A.L.

    1991-01-01

    Advancing technology in process plants has led to increased need for computer based process diagnostic systems to assist the operator. One approach to this problem is to use an embedded knowledge based system to interpret measurement signals. Knowledge based systems using only symptom based rules are inadequate for real time diagnosis of dynamic systems; therefore a model based approach is necessary. Though several forms of model based reasoning have been proposed, the use of qualitative causal models incorporating first principles knowledge of process behavior structure, and function appear to have the most promise as a robust modeling methodology. In this paper the structure of a diagnostic system is described which uses model based reasoning and conventional numerical methods to perform process diagnosis. This system is being applied to emergency diesel generator system in nuclear stations

  8. A numerical two layer model for blood oxygenation in lungs

    International Nuclear Information System (INIS)

    Aminatai, A.

    2001-01-01

    In the modelling of the simultaneous transport of O 2 and CO 2 in the pulmonary circulation described in our earlier studies, the blood has been treated as a homogeneous layer of haemoglobin solution. Since the size of the erythrocyte is not negligible in comparison with that of the capillary, the blood can no longer be considered as a homogeneous fluid and hence, It is worthwhile to consider the blood flow as a two-phase flow consisting of cells and plasma. In the present study, the heterogeneous nature of blood has been proposed by considering the axial train model for the flow [whitmore (1967)], in order to analyze the effect of cell free plasma layer on the process of blood oxygenation in pulmonary capillaries. The proposed model consists of a core of suspended erythrocytes surrounded by a cell free plasma layer near the wall. The coupled system of convective diffusion equaions together with the physiologically relevant boundary, entrance and interface conditions is solved numerically by a four-point semi-implicit scheme to gether with a fixed point iterative technique. The distance traversed by the blood before getting fully oxygenated is computed. It is shown that the core haematocrit and the thickness of the cell depleted layer affect the oxygenation process significantly. It is found that (i) oxygen takes longest and carbondioxide is the fastest to attain equilibraton, (ii) the blood is completely oxygenated within one-fifth part of its transit and (iii) the rate of oxygenation is smaller in case of homogeneous model than that in heterogenous model in the capillary. Finally, the effect of various physiological parameters on the rate of oxygenation has been examined

  9. Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure.

    Science.gov (United States)

    Coorevits, L; Van den Abeele, A-M

    2015-07-01

    The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3%) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of -1.4 mL (-15.4%). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of -0.3 mL (-3.3%). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7%). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.

  10. Method for Business Process Management System Selection

    OpenAIRE

    Westelaken, van de, Thijs; Terwee, Bas; Ravesteijn, Pascal

    2013-01-01

    In recent years business process management (BPM) and specifically information systems that support the analysis, design and execution of processes (also called business process management systems (BPMS)) are getting more attention. This has lead to an increase in research on BPM and BPMS. However the research on BPMS is mostly focused on the architecture of the system and how to implement such systems. How to select a BPM system that fits the strategy and goals of a specific organization is ...

  11. Magnetic navigation system for the precise helical and translational motions of a microrobot in human blood vessels

    Science.gov (United States)

    Jeon, S. M.; Jang, G. H.; Choi, H. C.; Park, S. H.; Park, J. O.

    2012-04-01

    Different magnetic navigation systems (MNSs) have been investigated for the wireless manipulation of microrobots in human blood vessels. Here we propose a MNS and methodology for generation of both the precise helical and translational motions of a microrobot to improve its maneuverability in complex human blood vessel. We then present experiments demonstrating the helical and translational motions of a spiral-type microrobot to verify the proposed MNS.

  12. Development of DUMAS data processing system

    International Nuclear Information System (INIS)

    Sakamoto, Hiroshi

    1982-01-01

    In the field of nuclear experiments, the speed-up of data processing has been required recently along with the increase of the amount of data per event or the rate of event occurrence per unit time. In the DUMAS project of RCNP, the development of data processing system has been required, which can perform the high speed transfer and processing. The system should transfer the data of 5 multiwire proportional counters and other counters from the laboratory to the counting room at the rate of 1000 events every second, and also should perform considerably complex processes such as histogramming, particle identification, calculation of various polarizations as well as dumping to the secondary memory in the counting room. Furthermore, easy start-up, adjustment, inspection and maintenance and non-special hardware and software should be considered. A system presently being investigated for satisfying the above requirements is described. The main points are as follows: to employ CAMAC system for the interface with readout circuit, to transfer data between the laboratory and the counting room by converting the byte-serial transfer to the bit-serial optical fiber communication, and to unify the data processing computers to the PDP-11 family by connecting two miniature computers. Development of such a data processing system seems to be useful as an preparatory research for the development of NUMATRON measuring instruments. (Wakatsuki, Y.)

  13. Next generation of non-mammalian blood-brain barrier models to study parasitic infections of the central nervous system

    Science.gov (United States)

    Siddiqui, Ruqaiyyah; Edwards-Smallbone, James; Flynn, Robin; Khan, Naveed Ahmed

    2012-01-01

    Transmigration of neuropathogens across the blood-brain barrier is a key step in the development of central nervous system infections, making it a prime target for drug development. The ability of neuropathogens to traverse the blood-brain barrier continues to inspire researchers to understand the specific strategies and molecular mechanisms that allow them to enter the brain. The availability of models of the blood-brain barrier that closely mimic the situation in vivo offers unprecedented opportunities for the development of novel therapeutics. PMID:21921682

  14. The effects of Anadara granosa shell-Stichopus hermanni on bFGF expressions and blood vessel counts in the bone defect healing process of Wistar rats

    Directory of Open Access Journals (Sweden)

    Rima Parwati Sari

    2017-12-01

    Full Text Available Background: Bone damage can be caused by various factors with treatment usually involving graft materials being applied to the defective area. Moreover, in the bone defect healing process, blood vessels are also considered to be an important energy source for cell proliferation. One of the angiogenic factors playing an important role in blood vessel formation is basic fibroblast growth factor (bFGF. Furthermore, synthesized hydroxyapatite derived from Anadara granosa (AG shells constitutes one of the potential materials for use in bone graft. The gold sea cucumber genus Stichopus hermanni (SH possesses the ability to stimulate endothelial progenitor cells inducing bFGF. Purpose: This study aims to investigate the effects of AG shells and SH on bFGF expressions and blood vessel counts within the bone healing process. Methods: Twenty four male Wistar rats were divided into three groups, namely: a control group (C, a treatment group was administered with blood cockle shell (AG, and a treatment group with blood cockle shell and golden sea cucumber (AG+SH. Defects were made on their femurs measuring half the diameter of a circular, no. 018. bur These rats were subsequently sacrificed on day 7 after surgery. The expressions of bFGF were measured by means of IHC technique, while the number of blood vessels was quantified using HE technique. The resulting data was subjected to statistical analysis using an Anova test followed by an LSD test (p < 0.05. Results: The one-way Anova test results combined with those of an LSD test showed there to be significant differences in bFGF expressions and blood vessel counts between the control group (K and the treatment group (AG as well as between the treatment group (AG and the treatment group (AG+SH. Conclusions: A combination of Anadara granosa shell and Stichopus hermanni can increase the expression of bFGF and the number of blood vessels on day 7 during the bone healing process in Wistar rats.

  15. High-speed video capillaroscopy method for imaging and evaluation of moving red blood cells

    Science.gov (United States)

    Gurov, Igor; Volkov, Mikhail; Margaryants, Nikita; Pimenov, Aleksei; Potemkin, Andrey

    2018-05-01

    The video capillaroscopy system with high image recording rate to resolve moving red blood cells with velocity up to 5 mm/s into a capillary is considered. Proposed procedures of the recorded video sequence processing allow evaluating spatial capillary area, capillary diameter and central line with high accuracy and reliability independently on properties of individual capillary. Two-dimensional inter frame procedure is applied to find lateral shift of neighbor images in the blood flow area with moving red blood cells and to measure directly the blood flow velocity along a capillary central line. The developed method opens new opportunities for biomedical diagnostics, particularly, due to long-time continuous monitoring of red blood cells velocity into capillary. Spatio-temporal representation of capillary blood flow is considered. Experimental results of direct measurement of blood flow velocity into separate capillary as well as capillary net are presented and discussed.

  16. Comparison of the clinical information provided by the FreeStyle Navigator continuous interstitial glucose monitor versus traditional blood glucose readings.

    Science.gov (United States)

    McGarraugh, Geoffrey V; Clarke, William L; Kovatchev, Boris P

    2010-05-01

    The purpose of the analysis was to compare the clinical utility of data from traditional self-monitoring of blood glucose (SMBG) to that of continuous glucose monitoring (CGM). A clinical study of the clinical accuracy of the FreeStyle Navigator CGM System (Abbott Diabetes Care, Alameda, CA), which includes SMBG capabilities, was conducted by comparison to the YSI blood glucose analyzer (YSI Inc., Yellow Springs, OH) using 58 subjects with type 1 diabetes. The Continuous Glucose-Error Grid Analysis (CG-EGA) was used as the analytical tool. Using CG-EGA, the "clinically accurate," "benign errors," and "clinical errors" were 86.8%, 8.7%, and 4.5% for SMBG and 92.7%, 3.7%, and 3.6% for CGM, respectively. If blood glucose is viewed as a process in time, SMBG would provide accurate information about this process 86.8% of the time, whereas CGM would provide accurate information about this process 92.7% of the time (P glucose values than CGM, control of blood glucose involves a system in flux, and CGM provides more detailed insight into the dynamics of that system. In the normal and elevated glucose ranges, the additional information about the direction and rate of glucose change provided by the FreeStyle Navigator CGM System increases the ability to make correct clinical decisions when compared to episodic SMBG tests.

  17. Process evaluation distributed system

    Science.gov (United States)

    Moffatt, Christopher L. (Inventor)

    2006-01-01

    The distributed system includes a database server, an administration module, a process evaluation module, and a data display module. The administration module is in communication with the database server for providing observation criteria information to the database server. The process evaluation module is in communication with the database server for obtaining the observation criteria information from the database server and collecting process data based on the observation criteria information. The process evaluation module utilizes a personal digital assistant (PDA). A data display module in communication with the database server, including a website for viewing collected process data in a desired metrics form, the data display module also for providing desired editing and modification of the collected process data. The connectivity established by the database server to the administration module, the process evaluation module, and the data display module, minimizes the requirement for manual input of the collected process data.

  18. Process-aware information systems : bridging people and software through process technology

    NARCIS (Netherlands)

    Dumas, M.; Aalst, van der W.M.P.; Hofstede, ter A.H.M.

    2005-01-01

    A unifying foundation to design and implement process-aware information systems This publication takes on the formidable task of establishing a unifying foundation and set of common underlying principles to effectively model, design, and implement process-aware information systems. Authored by

  19. System design of blood supply chain management based on Supplier Customer Relationship Management (SCRM approach

    Directory of Open Access Journals (Sweden)

    Allamsyah Zuhdi

    2018-01-01

    Full Text Available Blood supply chain management is very complex system. By considering blood’s demand that characterized as stochastic, therefore information and communication among stakeholders are considered as important cycle in supply chain. This research is objected to design interactive communication model based on information technology with android as platform to create effective customer-supplier relationship to support Customer Relationship Management or better known as CRM. The methods that suggested in designing its information system are Quality Function Deployment (QFD approach, Kano Model and Morphological Chart. From mentioned methods, attributes of design and specification priorities of purposed android system technology design are established. Attributes of design will be adjusted with customers’ requirements derived from customer voice that will further be integrated with technical responds in QFD. Technical responds will provide priorities on each design’s attribute of android information system and will be forwarded to the specifications determination by using morphological chart. Later, work flow of design system will be generated by using Data Flow Diagram (DFD. The result of the research will demonstrate the design of information system technology based on android that already adjusted with the requirement of donors as means of communication between suppliers and customers in blood supply chain.

  20. Interactive handling of regional cerebral blood flow data using a macrolanguage

    International Nuclear Information System (INIS)

    Sveinsdottir, E.; Schomacker, T.; Lassen, N.A.

    1976-01-01

    A general image handling software system has been developed for on-line collection, processing and display of gamma camera images (IMAGE system). The most distinguishable feature of the system is the ability for the user to interactively specify sequences, called macros, of basic functions to be performed. Information about a specified sequence is retained in the system, thus enabling new sequences or macros to be defined using already specified sequences. Facilities for parameter setting and parameter transfer between functions, as well as facilities for repetition of a function, are included. Finally, functions, be it basic or macro, can be specified to be iteratively activated using a physiological trigger signal as f.ex. the ECG. In addition, a special program system was developed for handling the dynamic data, from Xenon-133 studies of regional cerebral blood flow (CBF system). Parametric or functional images derived from the CBF system and depicting estimates of regional cerebral blood flow, relative weights of grey matter or other parameters can after computation be handled in the IMAGE system

  1. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  2. Systems biology of coagulation initiation: kinetics of thrombin generation in resting and activated human blood.

    Directory of Open Access Journals (Sweden)

    Manash S Chatterjee

    2010-09-01

    Full Text Available Blood function defines bleeding and clotting risks and dictates approaches for clinical intervention. Independent of adding exogenous tissue factor (TF, human blood treated in vitro with corn trypsin inhibitor (CTI, to block Factor XIIa will generate thrombin after an initiation time (T(i of 1 to 2 hours (depending on donor, while activation of platelets with the GPVI-activator convulxin reduces T(i to ∼20 minutes. Since current kinetic models fail to generate thrombin in the absence of added TF, we implemented a Platelet-Plasma ODE model accounting for: the Hockin-Mann protease reaction network, thrombin-dependent display of platelet phosphatidylserine, VIIa function on activated platelets, XIIa and XIa generation and function, competitive thrombin substrates (fluorogenic detector and fibrinogen, and thrombin consumption during fibrin polymerization. The kinetic model consisting of 76 ordinary differential equations (76 species, 57 reactions, 105 kinetic parameters predicted the clotting of resting and convulxin-activated human blood as well as predicted T(i of human blood under 50 different initial conditions that titrated increasing levels of TF, Xa, Va, XIa, IXa, and VIIa. Experiments with combined anti-XI and anti-XII antibodies prevented thrombin production, demonstrating that a leak of XIIa past saturating amounts of CTI (and not "blood-borne TF" alone was responsible for in vitro initiation without added TF. Clotting was not blocked by antibodies used individually against TF, VII/VIIa, P-selectin, GPIb, protein disulfide isomerase, cathepsin G, nor blocked by the ribosome inhibitor puromycin, the Clk1 kinase inhibitor Tg003, or inhibited VIIa (VIIai. This is the first model to predict the observed behavior of CTI-treated human blood, either resting or stimulated with platelet activators. CTI-treated human blood will clot in vitro due to the combined activity of XIIa and XIa, a process enhanced by platelet activators and which proceeds

  3. Development of Spreadsheet-Based Integrated Transaction Processing Systems and Financial Reporting Systems

    Science.gov (United States)

    Ariana, I. M.; Bagiada, I. M.

    2018-01-01

    Development of spreadsheet-based integrated transaction processing systems and financial reporting systems is intended to optimize the capabilities of spreadsheet in accounting data processing. The purpose of this study are: 1) to describe the spreadsheet-based integrated transaction processing systems and financial reporting systems; 2) to test its technical and operational feasibility. This study type is research and development. The main steps of study are: 1) needs analysis (need assessment); 2) developing spreadsheet-based integrated transaction processing systems and financial reporting systems; and 3) testing the feasibility of spreadsheet-based integrated transaction processing systems and financial reporting systems. The technical feasibility include the ability of hardware and operating systems to respond the application of accounting, simplicity and ease of use. Operational feasibility include the ability of users using accounting applications, the ability of accounting applications to produce information, and control applications of the accounting applications. The instrument used to assess the technical and operational feasibility of the systems is the expert perception questionnaire. The instrument uses 4 Likert scale, from 1 (strongly disagree) to 4 (strongly agree). Data were analyzed using percentage analysis by comparing the number of answers within one (1) item by the number of ideal answer within one (1) item. Spreadsheet-based integrated transaction processing systems and financial reporting systems integrate sales, purchases, and cash transaction processing systems to produce financial reports (statement of profit or loss and other comprehensive income, statement of changes in equity, statement of financial position, and statement of cash flows) and other reports. Spreadsheet-based integrated transaction processing systems and financial reporting systems is feasible from the technical aspects (87.50%) and operational aspects (84.17%).

  4. Effect of Metoclopramide on Portal Blood Flow in Patients with Liver Cirrhosis: Evaluation by the Pulsed Doppler System

    International Nuclear Information System (INIS)

    Baik, Soon Koo; Lee, Yong Gyu; Hong, Sa Joon; Lee, Seong Wu; Lee, Dong Ki; Kwong, Sang Ok

    1994-01-01

    Metoclopramide is known to lower the intravariceal flow by raising the lower esophageal sphincter pressure and consequently decreases the portal blood flow. So we designed this study to assess the effect of metoclopramide on portal blood flow in cirrhotic patients using pulsed Doppler system. By using pulsed Doppler ultrasound, portal blood velocity, diameter of the portal vein, portal blood flow, blood pressure and pulse rate were measured at 15, 30 and 60 minutes after administration of 20mg metoclopramide in 16cirrhotic patients and compared with the basal values. In order 10 cirrhotic patients, normal saline was administrated, and the above mentioned parameters were measured. Wothin 15 minutes after intravenous administration of 20mg metoclopramide, portal blood velocity and portal blood flow decreased significantly, from 12.45+2.64 to 11.80+2.55cm/sec and from 1006.3+407.1 to 974.4+414.7ml/min, respectively(P<0.05). In placebo group,there was no significant change in measured parameters after administration of normal saline. These results support the hypothesis that metoclopramide significantly decreases the portal blood flow transiently in cirrhotic patients with portal hypertension

  5. Detection of cytomegalovirus in blood donors by PCR using the digene SHARP signal system assay: effects of sample preparation and detection methodology.

    OpenAIRE

    Krajden, M; Shankaran, P; Bourke, C; Lau, W

    1996-01-01

    Cytomegalovirus (CMV) is an important cause of transfusion-associated morbidity and mortality; however, only 0.4 to 12% of the blood products obtained from seropositive blood donors transmit infection. The effects of three commercially available whole-blood sample preparation kits on the detection of CMV PCR products by a semiquantitative adaptation of the Digene SHARP Signal System Assay (DSSSA) in samples from volunteer blood donors was assessed. Of 101 samples from seropositive blood donor...

  6. Effects of endurance training on blood pressure, blood pressure-regulating mechanisms, and cardiovascular risk factors.

    Science.gov (United States)

    Cornelissen, Véronique A; Fagard, Robert H

    2005-10-01

    Previous meta-analyses of randomized controlled trials on the effects of chronic dynamic aerobic endurance training on blood pressure reported on resting blood pressure only. Our aim was to perform a comprehensive meta-analysis including resting and ambulatory blood pressure, blood pressure-regulating mechanisms, and concomitant cardiovascular risk factors. Inclusion criteria of studies were: random allocation to intervention and control; endurance training as the sole intervention; inclusion of healthy sedentary normotensive or hypertensive adults; intervention duration of > or =4 weeks; availability of systolic or diastolic blood pressure; and publication in a peer-reviewed journal up to December 2003. The meta-analysis involved 72 trials, 105 study groups, and 3936 participants. After weighting for the number of trained participants and using a random-effects model, training induced significant net reductions of resting and daytime ambulatory blood pressure of, respectively, 3.0/2.4 mm Hg (Phypertensive study groups (-6.9/-4.9) than in the others (-1.9/-1.6; Pendurance training decreases blood pressure through a reduction of vascular resistance, in which the sympathetic nervous system and the renin-angiotensin system appear to be involved, and favorably affects concomitant cardiovascular risk factors.

  7. Xeno- and auto-perfusion of rabbit kidney. Machine perfusion with blood at 37 degrees C

    DEFF Research Database (Denmark)

    Jørgensen, K A; Kemp, E; Barfort, P

    1985-01-01

    damage, exudation, and IgG deposits along the basement membrane of the glomerular capillaries were the discriminative features of the xenoperfusion. In these experiments, we were unable to demonstrate any major role of platelets in the process leading to decreased blood flow.......Five rabbit kidneys were perfused with human blood and another five with their own blood in a re-circulating oxygenated system at 37 degrees C. The flow decreased to 2 ml/min. within 30 min. in all xenoperfusions, while none of the autoperfused had decreased to this level by 60 min. Endothelial...

  8. Development and Evaluation of a Mobile Personalized Blood Glucose Prediction System for Patients With Gestational Diabetes Mellitus.

    Science.gov (United States)

    Pustozerov, Evgenii; Popova, Polina; Tkachuk, Aleksandra; Bolotko, Yana; Yuldashev, Zafar; Grineva, Elena

    2018-01-09

    Personalized blood glucose (BG) prediction for diabetes patients is an important goal that is pursued by many researchers worldwide. Despite many proposals, only a few projects are dedicated to the development of complete recommender system infrastructures that incorporate BG prediction algorithms for diabetes patients. The development and implementation of such a system aided by mobile technology is of particular interest to patients with gestational diabetes mellitus (GDM), especially considering the significant importance of quickly achieving adequate BG control for these patients in a short period (ie, during pregnancy) and a typically higher acceptance rate for mobile health (mHealth) solutions for short- to midterm usage. This study was conducted with the objective of developing infrastructure comprising data processing algorithms, BG prediction models, and an appropriate mobile app for patients' electronic record management to guide BG prediction-based personalized recommendations for patients with GDM. A mobile app for electronic diary management was developed along with data exchange and continuous BG signal processing software. Both components were coupled to obtain the necessary data for use in the personalized BG prediction system. Necessary data on meals, BG measurements, and other events were collected via the implemented mobile app and continuous glucose monitoring (CGM) system processing software. These data were used to tune and evaluate the BG prediction model, which included an algorithm for dynamic coefficients tuning. In the clinical study, 62 participants (GDM: n=49; control: n=13) took part in a 1-week monitoring trial during which they used the mobile app to track their meals and self-measurements of BG and CGM system for continuous BG monitoring. The data on 909 food intakes and corresponding postprandial BG curves as well as the set of patients' characteristics (eg, glycated hemoglobin, body mass index [BMI], age, and lifestyle parameters

  9. Advanced information processing system

    Science.gov (United States)

    Lala, J. H.

    1984-01-01

    Design and performance details of the advanced information processing system (AIPS) for fault and damage tolerant data processing on aircraft and spacecraft are presented. AIPS comprises several computers distributed throughout the vehicle and linked by a damage tolerant data bus. Most I/O functions are available to all the computers, which run in a TDMA mode. Each computer performs separate specific tasks in normal operation and assumes other tasks in degraded modes. Redundant software assures that all fault monitoring, logging and reporting are automated, together with control functions. Redundant duplex links and damage-spread limitation provide the fault tolerance. Details of an advanced design of a laboratory-scale proof-of-concept system are described, including functional operations.

  10. Process-aware information systems : design, enactment and analysis

    NARCIS (Netherlands)

    Aalst, van der W.M.P.; Wah, B.W.

    2009-01-01

    Process-aware information systems support operational business processes by combining advances in information technology with recent insights from management science. Workflow management systems are typical examples of such systems. However, many other types of information systems are also "process

  11. Development of the blood-brain barrier: a historical point of view.

    Science.gov (United States)

    Ribatti, Domenico; Nico, Beatrice; Crivellato, Enrico; Artico, Marco

    2006-01-01

    Although there has been considerable controversy since the observation by Ehrlich more than 100 years ago that the brain did not take up dyes from the vascular system, the concept of an endothelial blood-brain barrier (BBB) was confirmed by the unequivocal demonstration that the passage of molecules from blood to brain and vice versa was prevented by endothelial tight junctions (TJs). There are three major functions implicated in the term "BBB": protection of the brain from the blood milieu, selective transport, and metabolism or modification of blood- or brain-borne substances. The BBB phenotype develops under the influence of associated brain cells, especially astrocytic glia, and consists of complex TJs and a number of specific transport and enzyme systems that regulate molecular traffic across the endothelial cells. The development of the BBB is a complex process that leads to endothelial cells with unique permeability characteristics due to high electrical resistance and the expression of specific transporters and metabolic pathways. This review article summarizes the historical background underlying our current knowledge of the cellular and molecular mechanisms involved in the development and maintenance of the BBB. (c) 2006 Wiley-Liss, Inc.

  12. Spreading of blood drops over dry porous substrate: complete wetting case.

    Science.gov (United States)

    Chao, Tzu Chieh; Arjmandi-Tash, Omid; Das, Diganta B; Starov, Victor M

    2015-05-15

    The process of dried blood spot sampling involves simultaneous spreading and penetration of blood into a porous filter paper with subsequent evaporation and drying. Spreading of small drops of blood, which is a non-Newtonian liquid, over a dry porous layer is investigated from both theoretical and experimental points of view. A system of two differential equations is derived, which describes the time evolution of radii of both the drop base and the wetted region inside the porous medium. The system of equations does not include any fitting parameters. The predicted time evolutions of both radii are compared with experimental data published earlier. For a given power law dependency of viscosity of blood with different hematocrit level, radii of both drop base and wetted region, and contact angle fell on three universal curves if appropriate scales are used with a plot of the dimensionless radii of the drop base and the wetted region inside the porous layer and dynamic contact angle on dimensionless time. The predicted theoretical relationships are three universal curves accounting satisfactorily for the experimental data. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  13. [Blood groups - minuses and pluses. Do the blood group antigens protect us from infectious diseases?].

    Science.gov (United States)

    Czerwiński, Marcin

    2015-06-25

    Human blood can be divided into groups, which is a method of blood classification based on the presence or absence of inherited erythrocyte surface antigens that can elicit immune response. According to the International Society of Blood Transfusion, there are 341 blood group antigens collected in 35 blood group systems. These antigens can be proteins, glycoproteins or glycosphingolipids, and function as transmembrane transporters, ion channels, adhesion molecules or receptors for other proteins. The majority of blood group antigens is present also on another types of cells. Due to their localization on the surface of cells, blood group antigens can act as receptors for various pathogens or their toxins, such as protozoa (malaria parasites), bacteria (Helicobacter pylori, Vibrio cholerae and Shigella dysenteriae) and viruses (Noroviruses, Parvoviruses, HIV). If the presence of group antigen (or its variant which arised due to mutation) is beneficial for the host (e.g. because pathogens are not able to bind to the cells), the blood group may become a selection trait, leading to its dissemination in the population exposed to that pathogen. There are thirteen blood group systems that can be related to pathogen resistance, and it seems that the particular influence was elicit by malaria parasites. It is generally thought that the high incidence of blood groups such as O in the Amazon region, Fy(a-b-) in Africa and Ge(-) in Papua-New Guinea is the result of selective pressure from malaria parasite. This review summarizes the data about relationship between blood groups and resistance to pathogens.

  14. Handbook of signal processing systems

    CERN Document Server

    Deprettere, Ed; Leupers, Rainer; Takala, Jarmo

    2013-01-01

    Handbook of Signal Processing Systems is organized in three parts. The first part motivates representative applications that drive and apply state-of-the art methods for design and implementation of signal processing systems; the second part discusses architectures for implementing these applications; the third part focuses on compilers and simulation tools, describes models of computation and their associated design tools and methodologies. This handbook is an essential tool for professionals in many fields and researchers of all levels.

  15. Preventing blood transfusion failures: FMEA, an effective assessment method.

    Science.gov (United States)

    Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza

    2017-06-30

    Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.

  16. Cobit system in the audit processes of the systems of computer systems

    Directory of Open Access Journals (Sweden)

    Julio Jhovany Santacruz Espinoza

    2017-12-01

    Full Text Available The present research work has been carried out to show the benefits of the use of the COBIT system in the auditing processes of the computer systems, the problem is related to: How does it affect the process of audits in the institutions, use of the COBIT system? The main objective is to identify the incidence of the use of the COBIT system in the auditing process used by computer systems within both public and private organizations; In order to achieve our stated objectives of the research will be developed first with the conceptualization of key terms for an easy understanding of the subject, as a conclusion: we can say the COBIT system allows to identify the methodology by using information from the IT departments, to determine the resources of the (IT Information Technology, specified in the COBIT system, such as files, programs, computer networks, including personnel that use or manipulate the information, with the purpose of providing information that the organization or company requires to achieve its objectives.

  17. An NRTA data processing system: PROMAC-J

    International Nuclear Information System (INIS)

    Ikawa, Koji; Ihara, Hitoshi; Nishimura, Hideo

    1993-09-01

    Study of the application of Near-Real-Time Materials Accountancy has been done as an advanced safeguards measure for a spent nuclear fuel reprocessing plant. Also, from the viewpoint of practical application of NRTA concept to a real plant, a data processing system for the NRTA has been developed in consideration of effectiveness and promptness of data processing of NRTA data obtained in the field, so that a user can easily handle the analysis of time sequential MUF data based on the decision analyses in the field. The NRTA data processing system was used for processes and analyses of the NRTA data obtained during the period from September to December, 1985, a full scale field test of the proposed NRTA model for the PNC Tokai reprocessing plant. The result of this field test showed that the NRTA data processing system would be useful to provide sufficient information under the real plant circumstance. The data processing system was improved reflecting the experiences obtained in the field test. This report describes hardwares and softwares of the JAERI NRTA data processing system that was developed as an improvement of the previous system that had been developed and transferred to the PNC Tokai reprocessing plant. Improvements were made on both hardware components and softwares. (author)

  18. An NRTA data processing system: PROMAC-J

    International Nuclear Information System (INIS)

    Ihara, Hitoshi; Nishimura, Hideo; Ikawa, Koji

    1991-03-01

    Study of the application of Near-Real-Time Materials accountancy has been done as an advanced safeguards measure for a spent nuclear fuel reprocessing plant. Also, from the viewpoint of practical application of NRTA concept to a real plant, a data processing system for the NRTA has been developed in consideration of effectiveness and promptness of data processing of NRTA data obtained in the field, so that a user can easily handle the analysis of time sequential MUF data based on the decision analyses in the field. The NRTA data processing system was used for process and analyses of the NRTA data obtained during the period from September to December, 1985, a full scale field test of the proposed NRTA model for the PNC Tokai reprocessing plant. The result of this field test showed that the NRTA data processing system would be useful to provide sufficient information under the real plant circumstance. The data processing system was improved reflecting the experiences obtained in the field test. This report describes hardwares and softwares of the JAERI NRTA data processing system that was developed as an improvement of the previous system that had been developed and transferred to the PNC Tokai reprocessing plant. Improvements were made on both hardware components and softwares. (author)

  19. Features, Events, and Processes: System Level

    Energy Technology Data Exchange (ETDEWEB)

    D. McGregor

    2004-04-19

    The primary purpose of this analysis is to evaluate System Level features, events, and processes (FEPs). The System Level FEPs typically are overarching in nature, rather than being focused on a particular process or subsystem. As a result, they are best dealt with at the system level rather than addressed within supporting process-level or subsystem level analyses and models reports. The System Level FEPs also tend to be directly addressed by regulations, guidance documents, or assumptions listed in the regulations; or are addressed in background information used in development of the regulations. This evaluation determines which of the System Level FEPs are excluded from modeling used to support the total system performance assessment for license application (TSPA-LA). The evaluation is based on the information presented in analysis reports, model reports, direct input, or corroborative documents that are cited in the individual FEP discussions in Section 6.2 of this analysis report.

  20. Automated blood-sample handling in the clinical laboratory.

    Science.gov (United States)

    Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O

    1990-09-01

    The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.

  1. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  2. [Xeroproteinography of the blood serum system in patients with diabetes mellitus].

    Science.gov (United States)

    Savina, L V; Chirvinskiĭ, N P; Tuev, A V; Bulavskaia, N V

    1987-01-01

    A study of the structure of a dry gel of proteins of the blood serum system (BSS) in diabetes mellitus patients brings to light, to a certain degree, the problem of possible conformation conversions in its proteins. A study was made of networks of xeroproteinograms (XPG) in patients with average and severe forms of insulin dependent type of diabetes mellitus. A study of the XPG structure has a diagnostic and prognostic value for obtaining data on the conformation stability of BSS globular proteins in diabetes mellitus.

  3. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  4. Dynamics Explorer science data processing system

    International Nuclear Information System (INIS)

    Smith, P.H.; Freeman, C.H.; Hoffman, R.A.

    1981-01-01

    The Dynamics Explorer project has acquired the ground data processing system from the Atmosphere Explorer project to provide a central computer facility for the data processing, data management and data analysis activities of the investigators. Access to this system is via remote terminals at the investigators' facilities, which provide ready access to the data sets derived from groups of instruments on both spacecraft. The original system has been upgraded with both new hardware and enhanced software systems. These new systems include color and grey scale graphics terminals, an augmentation computer, micrographies facility, a versatile data base with a directory and data management system, and graphics display software packages. (orig.)

  5. Blood collection and the labile blood components: what should the regulators ask for?

    Science.gov (United States)

    Maniatis, A; Adamides, E

    1998-01-01

    Efforts to promote the quality and safety of blood collection are underway in most European Union (EU) member states but the level of quality management continues to differ significantly not only between countries but also among Blood Collection Establishments (BCE's) within a country. The European Commission has asked for blood safety and self-sufficiency in the Community and has initiated action in this direction. What is sought is harmonization of practices in the transfusion chain but such cannot be accomplished solely through recommendations and directives given the sociocultural and economic differences among EU member states. Active support for the development of common standards and a common quality system as well as an inspection and accreditation system would certainly help. The goal of self-sufficiency should certainly be emphasized but may be difficult to achieve, given the unpredictability of factors that may affect demand and supply. Through bipartisan initiatives however, between the USA and EU, consensus regarding the issue of blood safety, could be reached.

  6. System Theory and Physiological Processes.

    Science.gov (United States)

    Jones, R W

    1963-05-03

    Engineers and physiologists working together in experimental and theoretical studies predict that the application of system analysis to biological processes will increase understanding of these processes and broaden the base of system theory. Richard W. Jones, professor of electrical engineering at Northwestern University, Evanston, Illinois, and John S. Gray, professor of physiology at Northwestern's Medical School, discuss these developments. Their articles are adapted from addresses delivered in Chicago in November 1962 at the 15th Annual Conference on Engineering in Medicine and Biology.

  7. A multitransputer parallel processing system (MTPPS)

    International Nuclear Information System (INIS)

    Jethra, A.K.; Pande, S.S.; Borkar, S.P.; Khare, A.N.; Ghodgaonkar, M.D.; Bairi, B.R.

    1993-01-01

    This report describes the design and implementation of a 16 node Multi Transputer Parallel Processing System(MTPPS) which is a platform for parallel program development. It is a MIMD machine based on message passing paradigm. The basic compute engine is an Inmos Transputer Ims T800-20. Transputer with local memory constitutes the processing element (NODE) of this MIMD architecture. Multiple NODES can be connected to each other in an identifiable network topology through the high speed serial links of the transputer. A Network Configuration Unit (NCU) incorporates the necessary hardware to provide software controlled network configuration. System is modularly expandable and more NODES can be added to the system to achieve the required processing power. The system is backend to the IBM-PC which has been integrated into the system to provide user I/O interface. PC resources are available to the programmer. Interface hardware between the PC and the network of transputers is INMOS compatible. Therefore, all the commercially available development software compatible to INMOS products can run on this system. While giving the details of design and implementation, this report briefly summarises MIMD Architectures, Transputer Architecture and Parallel Processing Software Development issues. LINPACK performance evaluation of the system and solutions of neutron physics and plasma physics problem have been discussed along with results. (author). 12 refs., 22 figs., 3 tabs., 3 appendixes

  8. Endogenous System Microbes as Treatment Process ...

    Science.gov (United States)

    Monitoring the efficacy of treatment strategies to remove pathogens in decentralized systems remains a challenge. Evaluating log reduction targets by measuring pathogen levels is hampered by their sporadic and low occurrence rates. Fecal indicator bacteria are used in centralized systems to indicate the presence of fecal pathogens, but are ineffective decentralized treatment process indicators as they generally occur at levels too low to assess log reduction targets. System challenge testing by spiking with high loads of fecal indicator organisms, like MS2 coliphage, has limitations, especially for large systems. Microbes that are endogenous to the decentralized system, occur in high abundances and mimic removal rates of bacterial, viral and/or parasitic protozoan pathogens during treatment could serve as alternative treatment process indicators to verify log reduction targets. To identify abundant microbes in wastewater, the bacterial and viral communities were examined using deep sequencing. Building infrastructure-associated bacteria, like Zoogloea, were observed as dominant members of the bacterial community in graywater. In blackwater, bacteriophage of the order Caudovirales constituted the majority of contiguous sequences from the viral community. This study identifies candidate treatment process indicators in decentralized systems that could be used to verify log removal during treatment. The association of the presence of treatment process indic

  9. Neuro-Coagulopathy: Blood Coagulation Factors in Central Nervous System Diseases.

    Science.gov (United States)

    De Luca, Ciro; Virtuoso, Assunta; Maggio, Nicola; Papa, Michele

    2017-10-12

    Blood coagulation factors and other proteins, with modulatory effects or modulated by the coagulation cascade have been reported to affect the pathophysiology of the central nervous system (CNS). The protease-activated receptors (PARs) pathway can be considered the central hub of this regulatory network, mainly through thrombin or activated protein C (aPC). These proteins, in fact, showed peculiar properties, being able to interfere with synaptic homeostasis other than coagulation itself. These specific functions modulate neuronal networks, acting both on resident (neurons, astrocytes, and microglia) as well as circulating immune system cells and the extracellular matrix. The pleiotropy of these effects is produced through different receptors, expressed in various cell types, in a dose- and time-dependent pattern. We reviewed how these pathways may be involved in neurodegenerative diseases (amyotrophic lateral sclerosis, Alzheimer's and Parkinson's diseases), multiple sclerosis, ischemic stroke and post-ischemic epilepsy, CNS cancer, addiction, and mental health. These data open up a new path for the potential therapeutic use of the agonist/antagonist of these proteins in the management of several central nervous system diseases.

  10. The absorbed dose to blood from blood-borne activity

    International Nuclear Information System (INIS)

    Hänscheid, H; Fernández, M; Lassmann, M

    2015-01-01

    The radiation absorbed dose to blood and organs from activity in the blood is relevant for nuclear medicine dosimetry and for research in biodosimetry. The present study provides coefficients for the average absorbed dose rates to the blood from blood-borne activity for radionuclides frequently used in targeted radiotherapy and in PET diagnostics. The results were deduced from published data for vessel radius-dependent dose rate coefficients and reasonable assumptions on the blood-volume distribution as a function of the vessel radius. Different parts of the circulatory system were analyzed separately. Vessel size information for heart chambers, aorta, vena cava, pulmonary artery, and capillaries was taken from published results of morphometric measurements. The remaining blood not contained in the mentioned vessels was assumed to reside in fractal-like vascular trees, the smallest branches of which are the arterioles or venules. The applied vessel size distribution is consistent with recommendations of the ICRP on the blood-volume distribution in the human. The resulting average absorbed dose rates to the blood per nuclear disintegration per milliliter (ml) of blood are (in 10 −11  Gy·s −1 ·Bq −1 ·ml) Y-90: 5.58, I-131: 2.49, Lu-177: 1.72, Sm-153: 2.97, Tc-99m: 0.366, C-11: 4.56, F-18: 3.61, Ga-68: 5.94, I-124: 2.55. Photon radiation contributes 1.1–1.2·10 −11  Gy·s −1 ·Bq −1 ·ml to the total dose rate for positron emitters but significantly less for the other nuclides. Blood self-absorption of the energy emitted by ß-particles in the whole blood ranges from 37% for Y-90 to 80% for Tc-99m. The correspondent values in vascular trees, which are important for the absorbed dose to organs, range from 30% for Y-90 to 82% for Tc-99m. (paper)

  11. Control measurement system in purex process

    International Nuclear Information System (INIS)

    Mani, V.V.S.

    1985-01-01

    The dependence of a bulk facility handling Purex Process on the control measurement system for evaluating the process performance needs hardly be emphasized. process control, Plant control, inventory control and quality control are the four components of the control measurement system. The scope and requirements of each component are different and the measurement methods are selected accordingly. However, each measurement system has six important elements. These are described in detail. The quality assurance programme carried out by the laboratory as a mechanism through which the quality of measurements is regularly tested and stated in quantitative terms is also explained in terms of internal and external quality assurance, with examples. Suggestions for making the control measurement system more responsive to the operational needs in future are also briefly discussed. (author)

  12. Blood metabolites and some fertility parameters in dairy cows under intensive management system

    International Nuclear Information System (INIS)

    Osman, Awad Ali

    1998-08-01

    Dairy farms (1, 2, 3 and 4) of the intensive management system were selected. They are located 50 kilometers south of Khartoum state in a semi-arid zone. The effect of management on some fertility parameters, blood metabolites and minerals were investigated. Changes in blood metabolites with stage of lactation were also monitored. Other parameters studied were body weight, body condition score at calving. The results revealed that days to first P 4 rise after calving and number of services per conception (NSPC) were lower in the farm s contained the cross-bred (Fresian X Zebu) compared to the farm contained the pure Fresian breed. The pure Fresian cows showed heavier weights and less body score at calving compared to the cross breed. Blood metabolites reflected the nutritional status of the dairy cows under study, plasma total protein, albumin, globulin, urea and Glucose did not show significant changes either either either between farms or in response to lactation stages. However, high levels of Globulins might indicate inflammation due to some diseases such as mastitis, metritis and lameness. Plasma level of Calcium and Phosphorous did not change significantly either between farms or due to stages of lactation.(Author)

  13. Method for Business Process Management System Selection

    NARCIS (Netherlands)

    Thijs van de Westelaken; Bas Terwee; Pascal Ravesteijn

    2013-01-01

    In recent years business process management (BPM) and specifically information systems that support the analysis, design and execution of processes (also called business process management systems (BPMS)) are getting more attention. This has lead to an increase in research on BPM and BPMS. However

  14. Donor Hemovigilance Programme in managing Blood Transfusion Needs: Complications of Whole Blood Donation

    OpenAIRE

    S Mangwana

    2013-01-01

    Background: Hemovigilance like quality systems and audits have become an integral part of Blood Transfusion Services in the developed countries and has contributed greatly to its development. Hemovigilance begins with donors and must enable the collection of information on reactions occurring during the donation of blood, selections of donors and to prevent such incidents. The aim of study was to help identify the trends of adverse events , occurring in blood donors at a tertiary-care hospita...

  15. Worldwide policies on epilepsy and blood donation: a survey among blood services.

    Science.gov (United States)

    Kellens, A; De Buck, E; Emonds, M-P; Vandekerckhove, P; Lagae, L

    2018-02-01

    Epilepsy is a common neurological disorder characterized by the appearance of seizures. Often, epilepsy patients are temporarily or permanently excluded from blood donation. To gain a better understanding of the policies that are currently applied, we performed a survey among blood services. A cross-sectional, Web-based questionnaire using the online Questback tool was developed and distributed to 46 representatives of blood services worldwide. The questionnaire was composed of nine questions. A total of 27 respondents, representing blood services in 26 countries on five continents, participated in the survey. Current policies range from permanent acceptance over temporary exclusion to permanent exclusion. Rationales for these different policies are diverse. The majority of blood services (59·3%) apply temporary exclusion as their policy, though no consensus exists on the length of time that epilepsy patients have to be medication-free or seizure-free. None of the respondents could provide data about adverse events in epilepsy patients during the blood donation process. The results of this survey indicate a large discrepancy in policies applied worldwide. A lack of scientific evidence could be one of the underlying reasons. Therefore, it is of paramount importance to further research the potential risks for donors and recipients regarding blood donation by people with epilepsy. This can then serve as a base for evidence-based policymaking and lead to safer and more effective blood transfusion programmes. © 2018 International Society of Blood Transfusion.

  16. Quality management in European screening laboratories in blood establishments: A view of current approaches and trends.

    Science.gov (United States)

    Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda

    2015-04-01

    The screening laboratory has a critical role in the post-transfusion safety. The success of its targets and efficiency depends on the management system used. Even though the European Union directive 2002/98/EC requires a quality management system in blood establishments, its requirements for screening laboratories are generic. Complementary approaches are needed to implement a quality management system focused on screening laboratories. This article briefly discusses the current good manufacturing practices and good laboratory practices, as well as the trends in quality management system standards. ISO 9001 is widely accepted in some European Union blood establishments as the quality management standard, however this is not synonymous of its successful application. The ISO "risk-based thinking" is interrelated with the quality risk-management process of the EuBIS "Standards and criteria for the inspection of blood establishments". ISO 15189 should be the next step on the quality assurance of a screening laboratory, since it is focused on medical laboratory. To standardize the quality management systems in blood establishments' screening laboratories, new national and European claims focused on technical requirements following ISO 15189 is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Signals, processes, and systems an interactive multimedia introduction to signal processing

    CERN Document Server

    Karrenberg, Ulrich

    2013-01-01

    This is a very new concept for learning Signal Processing, not only from the physically-based scientific fundamentals, but also from the didactic perspective, based on modern results of brain research. The textbook together with the DVD form a learning system that provides investigative studies and enables the reader to interactively visualize even complex processes. The unique didactic concept is built on visualizing signals and processes on the one hand, and on graphical programming of signal processing systems on the other. The concept has been designed especially for microelectronics, computer technology and communication. The book allows to develop, modify, and optimize useful applications using DasyLab - a professional and globally supported software for metrology and control engineering. With the 3rd edition, the software is also suitable for 64 bit systems running on Windows 7. Real signals can be acquired, processed and played on the sound card of your computer. The book provides more than 200 pre-pr...

  18. Structural Changes in the Surface of Red Blood Cell Membranes during Long-Term Donor Blood Storage

    Directory of Open Access Journals (Sweden)

    V. V. Moroz

    2012-01-01

    Full Text Available Objective: to study changes in the surface of red blood cell membranes of donor blood at the macro- and ultrastructural level during its storage for 30 days and to evaluate the functional state of the red blood cell membrane during the whole storage period. Material and methods. The investigation was conducted on human whole blood and packed red blood cells placed in the specialized packs containing the preservative CPDA-1, by using calibrated electroporation and atomic force microscopy and measuring plasma pH. Conclusion. The long-term, up to 30-day, storage of whole blood and packed red blood cells at 4°C was attended by lower plasma pH and increased hemolysis rate constant during calibrated electroporation and by the development of oxidative processes. The hemolysis rate constant was also higher in the packed red blood cells than that in the whole blood. On days 5—6, the membrane structure showed defects that developed, as the blood was stored, and caused irreversible cell membrane damage by day 30. Key words: donor blood, red blood cell membranes, atomic force microscopy.

  19. Systems integration processes for space nuclear electric propulsion systems

    International Nuclear Information System (INIS)

    Olsen, C.S.; Rice, J.W.; Stanley, M.L.

    1991-01-01

    The various components and subsystems that comprise a nuclear electric propulsion system should be developed and integrated so that each functions ideally and so that each is properly integrated with the other components and subsystems in the optimum way. This paper discusses how processes similar to those used in the development and intergration of the subsystems that comprise the Multimegawatt Space Nuclear Power System concepts can be and are being efficiently and effectively utilized for these purposes. The processes discussed include the development of functional and operational requirements at the system and subsystem level; the assessment of individual nuclear power supply and thruster concepts and their associated technologies; the conduct of systems integration efforts including the evaluation of the mission benefits for each system; the identification and resolution of concepts development, technology development, and systems integration feasibility issues; subsystem, system, and technology development and integration; and ground and flight subsystem and integrated system testing

  20. Designing and Constructing Blood Flow Monitoring System to Predict Pressure Ulcers on Heel

    Directory of Open Access Journals (Sweden)

    Akbari H.

    2014-06-01

    Full Text Available Background: A pressure ulcer is a complication related to the need for the care and treatment of primarily disabled and elderly people. With the decrease of the blood flow caused by the pressure loaded, ulcers are formed and the tissue will be wasted with the passage of time. Objective: The aim of this study was to construct blood flow monitoring system on the heel tissue which was under external pressure in order to evaluate the tissue treatment in the ulcer. Methods: To measure the blood flow changes, three infrared optical transmitters were used at the distances of 5, 10, and 15 mm to the receiver. Blood flow changes in heels were assessed in pressures 0, 30, and 60 mmHg. The time features were extracted for analysis from the recorded signal by MATLAB software. Changes of the time features under different pressures were evaluated at the three distances by ANOVA in SPSS software. The level of significance was considered at 0.05. Results: In this study, 15 subjects, including both male and female, with the mean age of 54±7 participated. The results showed that the signal amplitude, power and absolute signal decreased significantly when pressure on the tissue increased in different layers (p<0.05. Heart rate only decreased significantly in pressures more than 30 mmHg (p=0.02. In pressures more than 30 mmHg, in addition to a decrease in the time features, the pattern of blood flow signal changed and it wasn’t the same as noload signal. Conclusion: By detecting the time features, we can reach an early diagnosis to prognosticate the degeneration of the tissue under pressure and it can be recommended as a method to predict bedsores in the heel.

  1. Comparison of oxidative/antioxidative status of penile corpus cavernosum blood and peripheral venous blood.

    Science.gov (United States)

    Yeni, E; Gulum, M; Selek, S; Erel, O; Unal, D; Verit, A; Savas, M

    2005-01-01

    The aim of the study is to determine and to compare the oxidative and antioxidative status of penile corpus cavernosum and peripheral venous blood. A total of 28 adult healthy males were included in the study. Whole blood was simultaneously withdrawn from penile corpus cavernosum and the cubital vein and their plasma separated. Total antioxidant capacity (TAC), vitamin C, total protein, albumin, uric acid, bilirubin and total peroxide (TP) levels of both plasma samples were measured and compared. While TAC, total protein, albumin, bilirubin and uric acid levels were higher, vitamin C levels were lower in cavernosal blood than that of peripheral blood. On the other hand, TP level was found to be higher in penile blood samples than that of peripheral blood. We thought that the normal erectile process of the penile cavernosal body leads to increased production of oxidants as in the mechanism of ischaemia-reperfusion; however, the increase of TAC can prevent development of oxidative injury.

  2. The effect of illegal lead processing on blood lead levels in children living in the mining area

    Directory of Open Access Journals (Sweden)

    Ćorac Aleksandar

    2017-01-01

    Full Text Available Backgraund/Aim. The northern part of Kosovo was one of the largest lead and zinc production industries in Europe. Special attention has been paid to the landfill sites of these metals remained after past industrial activities. The inhabitants of Roma camps in this area are collecting led waste they process by crushing and melting in their shacks in primitively organized working environments. Because of all the aforementioned it was necessary to examine the concentration of blood lead level (BLL in the children aged less than 6 years inhabiting this area, especially taking care of blood analysis of children living in Roma camps. Methods. The study was conducted in the municipality of Leposavić, Province Kosovo and Metohija, Serbia. Totally 78 subjects participated in the study. All the subjects were divided into two groups: the group I consisting of 42 children who lived in the Romas camp, and the group II with 36 children from a city kindergarten. Based on the mathematical model WRPLOT we found out that both groups of patients were in the low risk zone for industrial contamination exposure. Blood analysis was done according to the protocol provided by ESA Lead Care. Results. The average age of participants in the study was 4.60 ± 1.63 years. The mean BBL in the children from the group 1 was 19.11 μg/dL and from the group 2 4.87 μg/dL. There was a statistically significant difference in the mean values of BBL between the groups (U = 39, p < 0.001. All of the children from the group 1 had BBL greater than 5 μg/dL in comparison to 38.9% of the children from the group 2 (χ2 = 35.75, p < 0.001. Conclusion. Although both groups were located outside the zone of direct spread of pollution, the results indicate high concentrations of lead in blood of all the examined children. The concentration was higher in the children who lived in the area in which illegal processing of lead waste took place. [Project of the Serbian Ministry of Education

  3. 78 FR 18353 - Guidance for Industry: Blood Establishment Computer System Validation in the User's Facility...

    Science.gov (United States)

    2013-03-26

    ... SUPPLEMENTARY INFORMATION section for electronic access to the guidance document. Submit electronic comments on... document entitled ``Guidance for Industry: Blood Establishment Computer System Validation in the User's... document to http://www.regulations.gov or written comments to the Division of Dockets Management (see...

  4. Aligning Business Process Quality and Information System Quality

    OpenAIRE

    Heinrich, Robert

    2013-01-01

    Business processes and information systems mutually affect each other in non-trivial ways. Frequently, the business process design and the information system design are not well aligned. This means that business processes are designed without taking the information system impact into account, and vice versa. Missing alignment at design time often results in quality problems at runtime, such as large response times of information systems, large process execution times, overloaded information s...

  5. Infiltration Pattern of Blood Monocytes into the Central Nervous System during Experimental Herpes Simplex Virus Encephalitis.

    Directory of Open Access Journals (Sweden)

    Rafik Menasria

    Full Text Available The kinetics and distribution of infiltrating blood monocytes into the central nervous system and their involvement in the cerebral immune response together with resident macrophages, namely microglia, were evaluated in experimental herpes simplex virus 1 (HSV-1 encephalitis (HSE. To distinguish microglia from blood monocyte-derived macrophages, chimeras were generated by conditioning C57BL/6 recipient mice with chemotherapy regimen followed by transplantation of bone morrow-derived cells that expressed the green fluorescent protein. Mice were infected intranasally with a sub-lethal dose of HSV-1 (1.2 x 10(6 plaque forming units. Brains were harvested prior to and on days 4, 6, 8 and 10 post-infection for flow cytometry and immunohistochemistry analysis. The amounts of neutrophils (P < 0.05 and "Ly6C hi" inflammatory monocytes (P < 0.001 significantly increased in the CNS compared to non-infected controls on day 6 post-infection, which corresponded to more severe clinical signs of HSE. Levels decreased on day 8 for both leukocytes subpopulations (P < 0.05 for inflammatory monocytes compared to non-infected controls to reach baseline levels on day 10 following infection. The percentage of "Ly6C low" patrolling monocytes significantly increased (P < 0.01 at a later time point (day 8, which correlated with the resolution phase of HSE. Histological analysis demonstrated that blood leukocytes colonized mostly the olfactory bulb and the brainstem, which corresponded to regions where HSV-1 particles were detected. Furthermore, infiltrating cells from the monocytic lineage could differentiate into activated local tissue macrophages that express the microglia marker, ionized calcium-binding adaptor molecule 1. The lack of albumin detection in the brain parenchyma of infected mice showed that the infiltration of blood leukocytes was not necessarily related to a breakdown of the blood-brain barrier but could be the result of a functional recruitment. Thus

  6. The Process of Systemic Change

    Science.gov (United States)

    Duffy, Francis M.; Reigeluth, Charles M.; Solomon, Monica; Caine, Geoffrey; Carr-Chellman, Alison A.; Almeida, Luis; Frick, Theodore; Thompson, Kenneth; Koh, Joyce; Ryan, Christopher D.; DeMars, Shane

    2006-01-01

    This paper presents several brief papers about the process of systemic change. These are: (1) Step-Up-To-Excellence: A Protocol for Navigating Whole-System Change in School Districts by Francis M. Duffy; (2) The Guidance System for Transforming Education by Charles M. Reigeluth; (3) The Schlechty Center For Leadership In School Reform by Monica…

  7. Human-Systems Integration Processes

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to baseline a Human-Systems Integration Processes (HSIP) document as a companion to the NASA-STD-3001 and Human Integration Design...

  8. Oscillating systems with cointegrated phase processes

    DEFF Research Database (Denmark)

    Østergaard, Jacob; Rahbek, Anders; Ditlevsen, Susanne

    2017-01-01

    We present cointegration analysis as a method to infer the network structure of a linearly phase coupled oscillating system. By defining a class of oscillating systems with interacting phases, we derive a data generating process where we can specify the coupling structure of a network...... that resembles biological processes. In particular we study a network of Winfree oscillators, for which we present a statistical analysis of various simulated networks, where we conclude on the coupling structure: the direction of feedback in the phase processes and proportional coupling strength between...... individual components of the system. We show that we can correctly classify the network structure for such a system by cointegration analysis, for various types of coupling, including uni-/bi-directional and all-to-all coupling. Finally, we analyze a set of EEG recordings and discuss the current...

  9. Amotosalen: Allogeneic Cellular Immunotherapies system, INTERCEPT Plasma System, INTERCEPT Platelet System, S 59.

    Science.gov (United States)

    2003-01-01

    Adis CommentsCerus Corporation is developing a variety of pathogen-inactivation systems, based on its Helinx technology. Three of the systems include amotosalen [S 59] as the inactivation compound. Amotosalen is a light-activated, DNA-, RNA-crosslinking psoralen compound, which is used to neutralise pathogens. The systems that utilise amotosalen are called the INTERCEPT Platelet System, the INTERCEPT Plasma System and the Allogeneic Cellular Immunotherapies (ACIT) system. The INTERCEPT Platelet System and INTERCEPT Plasma System are two of the systems that make up Cerus' INTERCEPT Blood Systems. The other system is the INTERCEPT Red Blood Cell System, which contains S 303 as the inactivation compound rather than amotosalen. Cerus' Helinx technology is able to prevent replication of DNA or RNA that is present in pathogens but not in the blood components being treated (e.g. platelets and plasma). When added to the blood components, the inactivation agent (in this case amotosalen) crosses the membrane or cell wall of the pathogen. When activated by light, amotosalen binds to the nucleic acid of the pathogen and prevents replication. This process prevents infection. INTERCEPT Platelet System: Cerus developed its INTERCEPT Platelet System, in collaboration with Baxter Healthcare, for use in blood centres. Platelets are an essential component of the coagulation process and may be required by patients undergoing surgery, cancer chemotherapy, transplantation or with bleeding disorders. The system is made up of an illuminator device, a compound absorption device and a processing kit containing amotosalen. In October 2002, the two companies announced that CE Mark approval had been received for the illuminator device for the INTERCEPT trade mark Blood System. Application of this technology to platelets is the first to be approved. As it is a new technology, the system is currently undergoing process validation in accordance with European Blood Bank GMP requirements. This

  10. Viable Bacteria Associated with Red Blood Cells and Plasma in Freshly Drawn Blood Donations

    DEFF Research Database (Denmark)

    Damgaard, Christian; Magnussen, Karin; Enevold, Christian

    2015-01-01

    ) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. SETTING: Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. PARTICIPANTS: 60 donors (≥50 years old....... CONCLUSIONS: Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing......OBJECTIVES: Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from...

  11. A Process Management System for Networked Manufacturing

    Science.gov (United States)

    Liu, Tingting; Wang, Huifen; Liu, Linyan

    With the development of computer, communication and network, networked manufacturing has become one of the main manufacturing paradigms in the 21st century. Under the networked manufacturing environment, there exist a large number of cooperative tasks susceptible to alterations, conflicts caused by resources and problems of cost and quality. This increases the complexity of administration. Process management is a technology used to design, enact, control, and analyze networked manufacturing processes. It supports efficient execution, effective management, conflict resolution, cost containment and quality control. In this paper we propose an integrated process management system for networked manufacturing. Requirements of process management are analyzed and architecture of the system is presented. And a process model considering process cost and quality is developed. Finally a case study is provided to explain how the system runs efficiently.

  12. The quest for an Indian blood law as of blood transfusion services regulatory framework

    Directory of Open Access Journals (Sweden)

    Pal Ranabir

    2011-01-01

    Full Text Available Background: Blood transfusion services are a vital part of the national health delivery system. The responsibility for ensuring a continuous supply of blood rests with health administrators, who need to galvanize entire communities towards regular and non-remunerated blood donation. Objective: The present study aimed to examine the prevailing global regulations and practices related to blood transfusion and press the case for a dedicated blood law in India. Materials and Methods: We attempted a comprehensive, annotated assembly of published studies on blood transfusion services in India. Data Abstraction and Synthesis: Laws related to blood transfusion services exist in India as a part of the Drugs and Cosmetics Law. In the developed world, most blood donors are unpaid volunteers who give blood for a community supply. In order to augment safe blood transfusion services in India, we have to develop operational legal guidelines on recruitment and retention of voluntary blood donors to direct related organizations for this imperative activity. Conclusion: Several factors, such as political will and a professional and ethical approach can help in formulating a common vision, building trust, by providing optimum information towards a social movement for the rational blood transfusion services. We have to come together for a dedicated blood law in order to improve the quality of blood transfusion services in India.

  13. Comparison of the clinical and microbiological characteristics of Campylobacter and Helicobacter bacteremia: the importance of time to blood culture positivity using the BACTEC blood culture systems.

    Science.gov (United States)

    Yamamoto, Kei; Hayakawa, Kayoko; Nagashima, Maki; Shimada, Kayo; Kutsuna, Satoshi; Takeshita, Nozomi; Kato, Yasuyuki; Kanagawa, Shuzo; Yamada, Koji; Mezaki, Kazuhisa; Kirikae, Teruo; Ohmagari, Norio

    2017-11-28

    Campylobacter spp. and Helicobacter spp. are rare but important causes of bacteremia in humans. Distinguishing these bacteria is complicated because of their similar phenotypic profiles. We conducted clinical and microbiological investigations of Campylobacter spp. or Helicobacter spp. bacteremia. Patients diagnosed with bacteremia from 2008 to 2014 were included. The clinical and microbiological characteristics of Campylobacter spp. and Helicobacter spp. bacteremia were compared. The BACTEC system was used in blood cultures. A receiver operating characteristic curve was plotted based on the time to blood culture positivity. Sixteen cases of Helicobacter spp. bacteremia (patient age: 61 ± 18 years) and 14 cases of Campylobacter spp. bacteremia (patient age: 49 ± 21 years) were identified. Median time to blood culture positivity was longer for the Helicobacter spp. cases than the Campylobacter spp. cases (91.4 h vs 55.3 h, p culture positivity > 75 h predicted Helicobacter spp. bacteremia with a sensitivity of 0.88 and a specificity of 0.93 (area under the receiver operating characteristic curve of 0.90). In conclusion, a time to blood culture positivity was useful in distinguishing Helicobacter spp. bacteremia from Campylobacter spp. bacteremia.

  14. Enterprise and system of systems capability development life-cycle processes.

    Energy Technology Data Exchange (ETDEWEB)

    Beck, David Franklin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-08-01

    This report and set of appendices are a collection of memoranda originally drafted circa 2007-2009 for the purpose of describing and detailing a models-based systems engineering approach for satisfying enterprise and system-of-systems life cycle process requirements. At the time there was interest and support to move from Capability Maturity Model Integration (CMMI) Level One (ad hoc processes) to Level Three. The main thrust of the material presents a rational exposâe of a structured enterprise development life cycle that uses the scientific method as a framework, with further rigor added from adapting relevant portions of standard systems engineering processes. While the approach described invokes application of the Department of Defense Architectural Framework (DoDAF), it is suitable for use with other architectural description frameworks.

  15. Light scattering method to measure red blood cell aggregation during incubation

    Science.gov (United States)

    Grzegorzewski, B.; Szołna-Chodór, A.; Baryła, J.; DreŻek, D.

    2018-01-01

    Red blood cell (RBC) aggregation can be observed both in vivo as well as in vitro. This process is a cause of alterations of blood flow in microvascular network. Enhanced RBC aggregation makes oxygen and nutrients delivery difficult. Measurements of RBC aggregation usually give a description of the process for a sample where the state of a solution and cells is well-defined and the system reached an equilibrium. Incubation of RBCs in various solutions is frequently used to study the effects of the solutions on the RBC aggregation. The aggregation parameters are compared before and after incubation while the detailed changes of the parameters during incubation remain unknown. In this paper we have proposed a method to measure red blood cell aggregation during incubation based on the well-known technique where backscattered light is used to assess the parameters of the RBC aggregation. Couette system consisting of two cylinders is adopted in the method. The incubation is observed in the Couette system. In the proposed method following sequence of rotations is adapted. Two minutes rotation is followed by two minutes stop. In this way we have obtained a time series of back scattered intensity consisting of signals respective for disaggregation and aggregation. It is shown that the temporal changes of the intensity manifest changes of RBC aggregation during incubation. To show the ability of the method to assess the effect of incubation time on RBC aggregation the results are shown for solutions that cause an increase of RBC aggregation as well as for the case where the aggregation is decreased.

  16. Transcytosis in the blood–cerebrospinal fluid barrier of the mouse brain with an engineered receptor/ligand system

    Directory of Open Access Journals (Sweden)

    Héctor R Méndez-Gómez

    Full Text Available Crossing the blood–brain and the blood–cerebrospinal fluid barriers (BCSFB is one of the fundamental challenges in the development of new therapeutic molecules for brain disorders because these barriers prevent entry of most drugs from the blood into the brain. However, some large molecules, like the protein transferrin, cross these barriers using a specific receptor that transports them into the brain. Based on this mechanism, we engineered a receptor/ligand system to overcome the brain barriers by combining the human transferrin receptor with the cohesin domain from Clostridium thermocellum, and we tested the hybrid receptor in the choroid plexus of the mouse brain with a dockerin ligand. By expressing our receptor in choroidal ependymocytes, which are part of the BCSFB, we found that our systemically administrated ligand was able to bind to the receptor and accumulate in ependymocytes, where some of the ligand was transported from the blood side to the brain side.

  17. Cord blood buffy coat DNA methylation is comparable to whole cord blood methylation.

    Science.gov (United States)

    Dou, John; Schmidt, Rebecca J; Benke, Kelly S; Newschaffer, Craig; Hertz-Picciotto, Irva; Croen, Lisa A; Iosif, Ana-Maria; LaSalle, Janine M; Fallin, M Daniele; Bakulski, Kelly M

    2018-01-01

    Cord blood DNA methylation is associated with numerous health outcomes and environmental exposures. Whole cord blood DNA reflects all nucleated blood cell types, while centrifuging whole blood separates red blood cells, generating a white blood cell buffy coat. Both sample types are used in DNA methylation studies. Cell types have unique methylation patterns and processing can impact cell distributions, which may influence comparability. We evaluated differences in cell composition and DNA methylation between cord blood buffy coat and whole cord blood samples. Cord blood DNA methylation was measured with the Infinium EPIC BeadChip (Illumina) in eight individuals, each contributing buffy coat and whole blood samples. We analyzed principal components (PC) of methylation, performed hierarchical clustering, and computed correlations of mean-centered methylation between pairs. We conducted moderated t-tests on single sites and estimated cell composition. DNA methylation PCs were associated with individual (P PC1 = 1.4 × 10 -9 ; P PC2 = 2.9 × 10 -5 ; P PC3 = 3.8 × 10 -5 ; P PC4 = 4.2 × 10 -6 ; P PC5 = 9.9 × 10 -13 , P PC6 = 1.3 × 10 -11 ) and not with sample type (P PC1-6 >0.7). Samples hierarchically clustered by individual. Pearson correlations of mean-centered methylation between paired samples ranged from r = 0.66 to r = 0.87. No individual site significantly differed between buffy coat and whole cord blood when adjusting for multiple comparisons (five sites had unadjusted Pcoat and whole cord blood are much lower than inter-individual variation, demonstrating that both sample preparation types can be analytically combined and compared.

  18. Information processing in decision-making systems.

    Science.gov (United States)

    van der Meer, Matthijs; Kurth-Nelson, Zeb; Redish, A David

    2012-08-01

    Decisions result from an interaction between multiple functional systems acting in parallel to process information in very different ways, each with strengths and weaknesses. In this review, the authors address three action-selection components of decision-making: The Pavlovian system releases an action from a limited repertoire of potential actions, such as approaching learned stimuli. Like the Pavlovian system, the habit system is computationally fast but, unlike the Pavlovian system permits arbitrary stimulus-action pairings. These associations are a "forward'' mechanism; when a situation is recognized, the action is released. In contrast, the deliberative system is flexible but takes time to process. The deliberative system uses knowledge of the causal structure of the world to search into the future, planning actions to maximize expected rewards. Deliberation depends on the ability to imagine future possibilities, including novel situations, and it allows decisions to be taken without having previously experienced the options. Various anatomical structures have been identified that carry out the information processing of each of these systems: hippocampus constitutes a map of the world that can be used for searching/imagining the future; dorsal striatal neurons represent situation-action associations; and ventral striatum maintains value representations for all three systems. Each system presents vulnerabilities to pathologies that can manifest as psychiatric disorders. Understanding these systems and their relation to neuroanatomy opens up a deeper way to treat the structural problems underlying various disorders.

  19. Residual blood processing by centrifugation, cell salvage or ultrafiltration in cardiac surgery: effects on clinical hemostatic and ex-vivo rheological parameters.

    Science.gov (United States)

    Vonk, Alexander B; Muntajit, Warayouth; Bhagirath, Pranav; van Barneveld, Laurentius J; Romijn, Johannes W; de Vroege, Roel; Boer, Christa

    2012-10-01

    The study compared the effects of three blood concentration techniques after cardiopulmonary bypass on clinical hemostatic and ex-vivo rheological parameters. Residual blood of patients undergoing elective cardiac surgery was processed by centrifugation, cell salvage or ultrafiltration, and retransfused (n = 17 per group). Study parameters included blood loss, (free) hemoglobin, hematocrit, fibrinogen and erythrocyte aggregation, deformability and 2,3-diphosphoglycerate content. Patient characteristics were similar between groups. Ultrafiltration was associated with the highest weight of the transfusion bag [649 ± 261 vs. 320 ± 134 g (centrifugation) and 391 ± 158 g (cell salvage); P levels in the transfusion bag. Retransfusion of cell saver blood induced the largest gain in postoperative patient hemoglobin levels when compared to centrifugation and ultrafiltration, and was associated with the largest increase in 2,3-diphosphoglycerate when compared to ultrafiltration (Δ2,3-diphosphoglycerate 1.34 ± 1.92 vs. -0.77 ± 1.56 mmol/l; P = 0.03). Cell salvage is superior with respect to postoperative hemoglobin gain and washout of free hemoglobin when compared to centrifugation or ultrafiltration.

  20. Blood donation and institutional trust: risk, policy rhetoric, and the men who have sex with men lifetime deferral policy in Canada.

    Science.gov (United States)

    Smith, André; Fiddler, Jay; Walby, Kevin; Hier, Sean

    2011-11-01

    This article examines the process of rebuilding institutional trust in the Canadian blood system in the aftermath of the tainted blood scandal. Our focus is the policy of lifetime deferral from donating blood for men who have sex with men. Drawing on findings from interviews with representatives of Health Canada's Expert Advisory Committee on Blood Regulation, the National Liaison Committee, Canadian Blood Services, and blood consumer groups, we demonstrate how claims making about rights, discrimination, science, and risk contribute to policy continuity. We also examine the link between policy continuity and the management of reputational risk.

  1. Nanotoxicity of poly(n-butylcyano-acrylate) nanoparticles at the blood-brain barrier, in human whole blood and in vivo.

    Science.gov (United States)

    Kolter, Marise; Ott, Melanie; Hauer, Christian; Reimold, Isolde; Fricker, Gert

    2015-01-10

    Therapy of diseases of the central nervous system is a major challenge since drugs have to overcome the blood-brain barrier (BBB). A powerful strategy to enhance cerebral drug concentration is administration of drug-loaded poly(n-butylcyano-acrylate) (PBCA) nanoparticles coated with polysorbate 80 (PS80). This study evaluates the toxicity of PBCA-nanoparticles at the BBB, representing the target organ, the inflammatory response in human whole blood, as the site of administration and in a rat model in vivo. PBCA-nanoparticles were prepared by a mini-emulsion method and characterized concerning size, surface charge, shape and PS80-adsorption. The influence on metabolic activity, cell viability and integrity of the BBB was analyzed in an in vitro model of the BBB. In ex vivo experiments in human whole blood the release of 12 inflammatory cytokines was investigated. In addition, the inflammatory response was studied in vivo in rats and complemented with the analysis of different organ toxicity parameters. PBCA-nanoparticles showed time- and concentration-dependent effects on metabolic activity, cell viability and BBB integrity. No cell death or loss of metabolic activity was observed for nanoparticle-concentrations ≤500μg/ml up to 3h of treatment. Within 12 tested inflammatory cytokines, only interleukin-8 displayed a significant release after nanoparticle exposure in human blood. No severe inflammatory processes or organ damages were identified in rats in vivo. Thus, PBCA-nanoparticles are a promising drug delivery system to overcome the BBB since they showed hardly any cytotoxic or inflammatory effect at therapeutic concentrations and incubation times. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. System and method for deriving a process-based specification

    Science.gov (United States)

    Hinchey, Michael Gerard (Inventor); Rash, James Larry (Inventor); Rouff, Christopher A. (Inventor)

    2009-01-01

    A system and method for deriving a process-based specification for a system is disclosed. The process-based specification is mathematically inferred from a trace-based specification. The trace-based specification is derived from a non-empty set of traces or natural language scenarios. The process-based specification is mathematically equivalent to the trace-based specification. Code is generated, if applicable, from the process-based specification. A process, or phases of a process, using the features disclosed can be reversed and repeated to allow for an interactive development and modification of legacy systems. The process is applicable to any class of system, including, but not limited to, biological and physical systems, electrical and electro-mechanical systems in addition to software, hardware and hybrid hardware-software systems.

  3. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting.

    Science.gov (United States)

    Klaff, Leslie J; Brazg, Ronald; Hughes, Kristen; Tideman, Ann M; Schachner, Holly C; Stenger, Patricia; Pardo, Scott; Dunne, Nancy; Parkes, Joan Lee

    2015-01-01

    This study evaluated the accuracy of Contour(®) Next (CN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ) compared with five blood glucose monitoring systems (BGMSs) across a wide range of clinically occurring blood glucose levels. Subjects (n=146) were ≥ 18 years and had type 1 or type 2 diabetes. Subjects' glucose levels were safely lowered or raised to provide a wide range of glucose values. Capillary blood samples were tested on six BGMSs and a YSI glucose analyzer (YSI Life Sciences, Inc., Yellow Springs, OH) as the reference. Extreme glucose values were achieved by glucose modification of the blood sample. System accuracy was assessed by mean absolute difference (MAD) and mean absolute relative difference (MARD) across several glucose ranges, with glucose range (Abbott Diabetes Care, Inc., Alameda, CA), 2.77 mg/dL; OneTouch(®) Ultra(®) 2 (LifeScan, Inc., Milpitas, CA), 10.20 mg/dL; OneTouch(®) Verio(®) Pro (LifeScan, Inc.), 4.53 mg/dL; and Truetrack(®) (Nipro Diagnostics, Inc., Fort Lauderdale, FL), 11.08 mg/dL. The lowest MAD in the low glucose range, from CN, was statistically significantly lower than those of the other BGMSs with the exception of the FSL. CN also had a statistically significantly lower MARD than all other BGMSs in the low glucose range. In the overall glucose range (21-496 mg/dL), CN yielded the lowest MAD and MARD values, which were statistically significantly lower in comparison with the other BGMSs. When compared with other BGMSs, CN demonstrated the lowest mean deviation from the reference value (by MAD and MARD) across multiple glucose ranges.

  4. Blood donor haematology parameters in two regions of Kenya ...

    African Journals Online (AJOL)

    Objectives: To determine the status of blood donor haematology in two regional sites in Kenya and to assess the potential role of automated haematology in National blood bank process control. Design: A cross sectional descriptive study. Setting: Two regional blood banks - Nairobi and its environs (Blood Transfusion ...

  5. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.

    Science.gov (United States)

    Cakirca, Gokhan; Erdal, Huseyin

    2017-05-01

    Pneumatic tube systems (PTSs) are widely used in many hospitals because they lead to reduced turnaround times and cost efficiency. However, PTSs may affect the quality of the blood samples transported to the laboratory. The aim of this study was to investigate the effect of the PTS used in our hospital on the hemolysis of the biochemical blood samples transported to the laboratory. A total of 148 samples were manually transported to the laboratory by hospital staff, 148 samples were transported with the PTS, and 113 were transported with the PTS without use of sponge-rubber inserts (PTSws). Hemolysis rates and the levels of biochemical analytes for the different transportation methods were compared. No significant difference was found between the samples transported manually and with the PTS with regard to hemolysis rate and the levels of biochemical analytes. However, the samples transported with the PTSws showed a significant difference compared with the samples transported manually and with the PTS with regard to hemolysis rate and potassium and lactate dehydrogenase levels. The percentages of the samples that exceeded the permissible threshold for the hemolysis among the samples transported manually, with the PTS, and with the PTSws were 10%, 8%, and 47%, respectively. A PTS can be used safely for transporting biochemistry blood samples to the laboratory. However, a sponge-rubber insert that holds sample tubes must be used with the PTS to prevent the hemolysis of blood samples. Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  6. Eco-efficiency of grinding processes and systems

    CERN Document Server

    Winter, Marius

    2016-01-01

    This research monograph aims at presenting an integrated assessment approach to describe, model, evaluate and improve the eco-efficiency of existing and new grinding processes and systems. Various combinations of grinding process parameters and system configurations can be evaluated based on the eco-efficiency. The book presents the novel concept of empirical and physical modeling of technological, economic and environmental impact indicators. This includes the integrated evaluation of different grinding process and system scenarios. The book is a valuable read for research experts and practitioners in the field of eco-efficiency of manufacturing processes but the book may also be beneficial for graduate students.

  7. Process for Selecting System Level Assessments for Human System Technologies

    Science.gov (United States)

    Watts, James; Park, John

    2006-01-01

    The integration of many life support systems necessary to construct a stable habitat is difficult. The correct identification of the appropriate technologies and corresponding interfaces is an exhaustive process. Once technologies are selected secondary issues such as mechanical and electrical interfaces must be addressed. The required analytical and testing work must be approached in a piecewise fashion to achieve timely results. A repeatable process has been developed to identify and prioritize system level assessments and testing needs. This Assessment Selection Process has been defined to assess cross cutting integration issues on topics at the system or component levels. Assessments are used to identify risks, encourage future actions to mitigate risks, or spur further studies.

  8. Transfusion safety: is this the business of blood centers?

    Science.gov (United States)

    Slapak, Colleen; Fredrich, Nanci; Wagner, Jeffrey

    2011-12-01

    ATSO is in a unique position to break down organizational silos between hospitals and blood centers through the development of a collaborative relationship between the two entities. Use of the TSO as blood center staff centralizes the role into a consultative position thereby retaining the independence of the hospitals. The TSO position then becomes a value-added service offered by the blood center designed to supplement processes within the hospital.Whether the TSO is based in the hospital or the blood center, improvements are gained through appropriate utilization of blood components, reductions in hospital costs, ongoing education of hospital staff involved in transfusion practice, and increased availability of blood products within the community. Implementation and standardization of best practice processes for ordering and administration of blood products developed by TSOs leads to improved patient outcomes. As a liaison between hospitals and blood centers, the TSO integrates the mutual goal of transfusion safety: the provision of the safest blood product to the right patient at the right time for the right reason.

  9. Generic Health Management: A System Engineering Process Handbook Overview and Process

    Science.gov (United States)

    Wilson, Moses Lee; Spruill, Jim; Hong, Yin Paw

    1995-01-01

    Health Management, a System Engineering Process, is one of those processes-techniques-and-technologies used to define, design, analyze, build, verify, and operate a system from the viewpoint of preventing, or minimizing, the effects of failure or degradation. It supports all ground and flight elements during manufacturing, refurbishment, integration, and operation through combined use of hardware, software, and personnel. This document will integrate Health Management Processes (six phases) into five phases in such a manner that it is never a stand alone task/effort which separately defines independent work functions.

  10. Laboratory rearing of Cimex hemipterus F. (Hemiptera: Cimicidae feeding on different types of human blood compositions by using modifid artifiial feeding system

    Directory of Open Access Journals (Sweden)

    Abd Hafis Abd Rahim

    2015-12-01

    Full Text Available Objective: To investigate the effects of three types of human blood compositions: whole blood, red blood cells and red blood cells mixed with plasma, and determine the suitable blood source that can be used to feed the bed bugs [Cimex hemipterus (C. hemipterus], in comparison to the direct feeding method. Methods: C. hemipterus were fed with the three types of blood compositions by using an artificial feeding system. Then the number of live and dead individuals as well as the number of adults produced was counted. Results: Red blood cells caused 72.7% death of C. hemipterus, followed by red blood cells mixed with plasma (52.0% and whole blood (48.7%. There were significant differences in the number of live individuals after seven weeks of feeding. However, there were no significant differences between the number of live individuals fed on whole blood, red blood cells and red blood cells mixed with plasma after seven weeks. Conclusions: The components in the blood sources may be the key to their different effects on the growth dynamics of C. hemipterus.

  11. Process Information System - Nuclear Power Plant Krsko

    International Nuclear Information System (INIS)

    Mandic, D.; Barbic, B.; Linke, B.; Colak, I.

    1998-01-01

    Original NEK design was using several Process Computer Systems (PCS) for both process control and process supervision. PCS were built by different manufacturers around different hardware and software platforms. Operational experience and new regulatory requirements imposed new technical and functional requirements on the PCS. Requirements such as: - Acquisition of new signals from the technological processes and environment - Implementation of new application programs - Significant improvement of MMI (Man Machine Interface) - Process data transfer to other than Main Control Room (MCR) locations - Process data archiving and capability to retrieve same data for future analysis were impossible to be implemented within old systems. In order to satisfy new requirements, NEK has decided to build new Process Information System (PIS). During the design and construction of the PIS Project Phase I, in addition to the main foreign contractor, there was significant participation of local architect engineering and construction companies. This paper presents experience of NEK and local partners. (author)

  12. Red blood cell antigen genotype analysis for 9087 Asian, Asian American, and Native American blood donors.

    Science.gov (United States)

    Delaney, Meghan; Harris, Samantha; Haile, Askale; Johnsen, Jill; Teramura, Gayle; Nelson, Karen

    2015-10-01

    There has yet to be a comprehensive analysis of blood group antigen prevalence in Asian Americans and Native Americans. There may be ethnic differences in blood group frequencies that would result in clinically important mismatches through transfusion. Blood donors who self-identified as Asian or Native American were tested using a single-nucleotide polymorphism (SNP) DNA array (HEA BeadChip kit, Bioarray Solutions Ltd) that predicts expression of 38 human erythrocyte antigens (HEAs) and by serology for ABO, D, C, M, N, Jk(a) , and Jk(b) . The prevalence of blood group antigens was compared to published European prevalence. Discrepancies between SNP-predicted and serology-detected antigens were tallied. A total of 9087 blood donors were tested from nine Asian and Native American heritages. The predicted prevalence of selected antigens in the RHCE, JK, FY, MNS, LU, CO, and DO blood group systems were variable between Asian populations, but overall not significantly different than Europeans. Compared to European frequencies, Kell blood group allele frequencies were significantly different in the Chinese, Native American, Hawaiian/Pacific Islander, South Asian, and Southeast Asian heritage blood donors; Diego antigens Di(a) and Di(b) were different in donors of Native American and South Asian ancestries (p Asian and Native Americans donors. Several ethnic groups exhibited differences in HEA frequencies compared to Europeans. Genotype-serotype discrepancies were detected in all systems studied. © 2015 AABB.

  13. Blood and interstitial flow in the hierarchical pore space architecture of bone tissue.

    Science.gov (United States)

    Cowin, Stephen C; Cardoso, Luis

    2015-03-18

    There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen and reduced nutrition. Within the bone, as within other tissues, substances pass from the blood through the arterial walls into the interstitial fluid. The movement of the interstitial fluid carries these substances to the cells within the bone and, at the same time, carries off the waste materials from the cells. Bone tissue would not live without these fluid movements. The development of a model for poroelastic materials with hierarchical pore space architecture for the description of blood flow and interstitial fluid flow in living bone tissue is reviewed. The model is applied to the problem of determining the exchange of pore fluid between the vascular porosity and the lacunar-canalicular porosity in bone tissue due to cyclic mechanical loading and blood pressure. These results are basic to the understanding of interstitial flow in bone tissue that, in turn, is basic to understanding of nutrient transport from the vasculature to the bone cells buried in the bone tissue and to the process of mechanotransduction by these cells. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Interaction between blood-brain barrier and glymphatic system in solute clearance.

    Science.gov (United States)

    Verheggen, I C M; Van Boxtel, M P J; Verhey, F R J; Jansen, J F A; Backes, W H

    2018-03-30

    Neurovascular pathology concurs with protein accumulation, as the brain vasculature is important for waste clearance. Interstitial solutes, such as amyloid-β, were previously thought to be primarily cleared from the brain by blood-brain barrier transport. Recently, the glymphatic system was discovered, in which cerebrospinal fluid is exchanged with interstitial fluid, facilitated by the aquaporin-4 water channels on the astroglial endfeet. Glymphatic flow can clear solutes from the interstitial space. Blood-brain barrier transport and glymphatic clearance likely serve complementary roles with partially overlapping mechanisms providing a well-conditioned neuronal environment. Disruption of these mechanisms can lead to protein accumulation and may initiate neurodegenerative disorders, for instance amyloid-β accumulation and Alzheimer's disease. Although both mechanisms seem to have a similar purpose, their interaction has not been clearly discussed previously. This review focusses on this interaction in healthy and pathological conditions. Future health initiatives improving waste clearance might delay or even prevent onset of neurodegenerative disorders. Defining glymphatic flow kinetics using imaging may become an alternative way to identify those at risk of Alzheimer's disease. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Material & equipment, procurement & maintenance: Impact on blood safety.

    Science.gov (United States)

    Emmanuel, Jean C

    2010-01-01

    Blood Transfusion Safety is dependent on effectively organised and managed blood services, which have adequate financial resources, skilled manpower, appropriate infrastructure and quality management systems in place. 80% of the world's population has access to 20% of the supply blood products, of which little is consistently safe. HIV highlighted the importance of blood safety. The lack of effective blood services in low human development index (LHDI), developing countries, has lead to international funding and capacity building for more than three decades. The initial strategies focused on providing HIV testing reagents to prevention transmission, however this only addresses one part of blood safety. Blood safety is not only dependent on preventing HIV transmission. In many populations there are other infectious agents, which have a higher prevalence. Ensuring the correct blood is provided to the patient depends on: well managed services with effective leadership and adequate budgets; capacity building and retention of skilled experienced staff; availability of laboratory equipment, correctly maintained; blood cold chain systems; procedures for tendering, purchasing and ensuring an unbroken supply of reagents and consumables; and quality management systems. Barriers for simplified effective tendering, procurement and contracting require urgent attention and coordination of all funding organisations to ensure an unbroken supply of reagents. Copyright 2009. Published by Elsevier Ltd.

  16. Radio frequency tags systems to initiate system processing

    Science.gov (United States)

    Madsen, Harold O.; Madsen, David W.

    1994-09-01

    This paper describes the automatic identification technology which has been installed at Applied Magnetic Corp. MR fab. World class manufacturing requires technology exploitation. This system combines (1) FluoroTrac cassette and operator tracking, (2) CELLworks cell controller software tools, and (3) Auto-Soft Inc. software integration services. The combined system eliminates operator keystrokes and errors during normal processing within a semiconductor fab. The methods and benefits of this system are described.

  17. Cost effectiveness of cord blood versus bone marrow and peripheral blood stem cells

    Directory of Open Access Journals (Sweden)

    Thomas Bart

    2010-10-01

    Full Text Available Thomas BartSwiss Blood Stem Cells, Bern, SwitzerlandAbstract: Umbilical cord blood (CB has become, since its first successful use more than two decades ago, an increasingly important source of blood stem cells. In this light, an overview of current usage of CB in the field of unrelated hematopoietic blood stem cell transplantation (HSCT is given. The three main sources of hematopoietic stem cells: bone marrow (BM, peripheral blood stem cells (PBSC, and cord blood (CB are compared as regards their current quantitative usage in HSCT. A cost analysis of the named three hematopoietic blood stem cell (HSC sources, taking into account various factors, is undertaken. The health economical comparison shows significant differences between CB on the one side, and BM and PBSC on the other. The consequences for the public health side and propositions for a possible health care policy, especially regarding future resource allocation towards the different choices for HSCT products, are discussed. An outlook on the possible future usage of BM, PBSC, and CB and its implications on health systems, donor registries, and CB banks is given.Keywords: health economy, cord blood, hematopoietic stem cell transplantation

  18. Architecture Of High Speed Image Processing System

    Science.gov (United States)

    Konishi, Toshio; Hayashi, Hiroshi; Ohki, Tohru

    1988-01-01

    One of architectures for a high speed image processing system which corresponds to a new algorithm for a shape understanding is proposed. And the hardware system which is based on the archtecture was developed. Consideration points of the architecture are mainly that using processors should match with the processing sequence of the target image and that the developed system should be used practically in an industry. As the result, it was possible to perform each processing at a speed of 80 nano-seconds a pixel.

  19. Coastal oceanographic processes associated with blood cockle (Anadara granosa induce spawning season in Kapar, Selangor, Malaysia

    Directory of Open Access Journals (Sweden)

    Hadzley Harith

    2016-12-01

    Full Text Available Study on coastal processes in Kapar waters was conducted from 2008–2016. The aim of this study is to identify potential blood cockle (Anadara granosa induce spawning ground based on physical intermittency. A total of 132 sampling stations were recorded. A thermal power station situated 2km away is discharging treated warm water (3m MSL which prevents cockle farmers from harvesting due to their maximum of 3m long hand dredge. Thus, this information could be useful for cockle sustainable management plan in near future.

  20. Recruitment of feces donors among blood donors

    DEFF Research Database (Denmark)

    Dahl Jørgensen, Simon Mark; Erikstrup, Christian; Dinh, Khoa Manh

    2018-01-01

    As the use of fecal microbiota transplantation (FMT) has gained momentum, an increasing need for continuous access to healthy feces donors has developed. Blood donors constitute a healthy subset of the general population and may serve as an appropriate group for recruitment. In this study, we...... investigated the suitability of blood donors as feces donors. In a prospective cohort study, we recruited blood donors onsite at a public Danish blood bank. Following their consent, the blood donors underwent a stepwise screening process: First, blood donors completed an electronic pre-screening questionnaire...... to rule out predisposing risk factors. Second, eligible blood donors had blood and fecal samples examined. Of 155 blood donors asked to participate, 137 (88%) completed the electronic pre-screening questionnaire, 16 declined, and 2 were excluded. Of the 137 donors who completed the questionnaire, 79 (58...