  1. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  3. The effect of ventricular assist devices on cerebral blood flow and blood pressure fractality

    International Nuclear Information System (INIS)

    Bellapart, Judith; Fraser, John F; Chan, Gregory S H; Tzeng, Yu-Chieh; Ainslie, Philip N; Dunster, Kimble R; Barnett, Adrian G; Boots, Rob

    2011-01-01

    Biological signals often exhibit self-similar or fractal scaling characteristics which may reflect intrinsic adaptability to their underlying physiological system. This study analysed fractal dynamics of cerebral blood flow in patients supported with ventricular assist devices (VAD) to ascertain if sustained modifications of blood pressure waveform affect cerebral blood flow fractality. Simultaneous recordings of arterial blood pressure and cerebral blood flow velocity using transcranial Doppler were obtained from five cardiogenic shock patients supported by VAD, five matched control patients and five healthy subjects. Computation of a fractal scaling exponent (α) at the low-frequency time scale by detrended fluctuation analysis showed that cerebral blood flow velocity exhibited 1/f fractal scaling in both patient groups (α = 0.95 ± 0.09 and 0.97 ± 0.12, respectively) as well as in the healthy subjects (α = 0.86 ± 0.07). In contrast, fluctuation in blood pressure was similar to non-fractal white noise in both patient groups (α = 0.53 ± 0.11 and 0.52 ± 0.09, respectively) but exhibited 1/f scaling in the healthy subjects (α = 0.87 ± 0.04, P < 0.05 compared with the patient groups). The preservation of fractality in cerebral blood flow of VAD patients suggests that normal cardiac pulsation and central perfusion pressure changes are not the integral sources of cerebral blood flow fractality and that intrinsic vascular properties such as cerebral autoregulation may be involved. However, there is a clear difference in the fractal scaling properties of arterial blood pressure between the cardiogenic shock patients and the healthy subjects

  4. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  5. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  6. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  7. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    Science.gov (United States)

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  8. A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study

    NARCIS (Netherlands)

    Schoot, T.S.; Weenk, M.; Belt, T.H. van de; Engelen, L.J.L.P.G.; Goor, H. van; Bredie, S.J.H.

    2016-01-01

    BACKGROUND: Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP

  9. A novel wearable device for continuous, non-invasion blood pressure measurement.

    Science.gov (United States)

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  10. How Accurate Are Home Blood Pressure Devices in Use? A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Marcel Ruzicka

    Full Text Available Out of office blood pressure measurements, using either home monitors or 24 hour ambulatory monitoring, is widely recommended for management of hypertension. Though validation protocols, meant to be used by manufacturers, exist for blood pressure monitors, there is scant data in the literature about the accuracy of home blood pressure monitors in actual clinical practice. We performed a chart review in the blood pressure assessment clinic at a tertiary care centre.We assessed the accuracy of home blood pressure monitors used by patients seen in the nephrology clinic in Ottawa between the years 2011 to 2014. We recorded patient demographics and clinical data, including the blood pressure measurements, arm circumference and the manufacturer of the home blood pressure monitor. The average of BP measurements performed with the home blood pressure monitor, were compared to those with the mercury sphygmomanometer. We defined accuracy based on a difference of 5 mm Hg in the blood pressure values between the home monitor and mercury sphygmomanometer readings. The two methods were compared using a Bland-Altman plot and a student's t-test.The study included 210 patients. The mean age of the study population was 67 years and 61% was men. The average mid-arm circumference was 32.2 cms. 30% and 32% of the home BP monitors reported a mean systolic and diastolic BP values, respectively, different from the mercury measurements by 5 mm Hg or more. There was no significant difference between the monitors that were accurate versus those that were not when grouped according to the patient characteristics, cuff size or the brand of the home monitor.An important proportion of home blood pressure monitors used by patients seen in our nephrology clinic were inaccurate. A re-validation of the accuracy and safety of the devices already in use is prudent before relying on these measurements for clinical decisions.

  11. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  12. Development and Validation of a Novel Cuff-Less Blood Pressure Monitoring Device

    Directory of Open Access Journals (Sweden)

    Naoki Watanabe, MD

    2017-12-01

    Full Text Available Ordinary cuff-based blood pressure–monitoring devices remain a technical limitation that disturbs activities of daily life. Here we report a novel system for the cuff-less blood pressure estimation (CLB that requires only 1 sensor for photoplethysmography. The present study is the first report to validate and assess the clinical application of the CLB in accordance with the latest wearable device standard (issued by the Institute of Electrical and Electronics Engineers, standard 1708-2014. Our CLB is expected to offer a flexible and wearable device that permits blood pressure monitoring in more continuous and stress-free settings.

  13. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

    Science.gov (United States)

    Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao

    2002-04-01

    Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar

  14. Diurnal blood pressure changes.

    Science.gov (United States)

    Asayama, Kei; Satoh, Michihiro; Kikuya, Masahiro

    2018-05-23

    The definition of diurnal blood pressure changes varies widely, which can be confusing. Short-term blood pressure variability during a 24-h period and the dipping status of diurnal blood pressure can be captured by ambulatory blood pressure monitoring, and these metrics are reported to have prognostic significance for cardiovascular complications. Morning blood pressure surge also indicates this risk, but its effect may be limited to populations with specific conditions. Meanwhile, the combined use of conventional office blood pressure and out-of-office blood pressure allows us to identify people with white-coat and masked hypertension. Current home devices can measure nocturnal blood pressure during sleep more conveniently than ambulatory monitoring; however, we should pay attention to blood pressure measurement conditions regardless of whether they are in a home, ambulatory, or office setting. The relatively poor reproducibility of diurnal blood pressure changes, including the nocturnal fall of blood pressure, is another underestimated issue to be addressed. Although information on diurnal blood pressure changes is expected to be used more effectively in the future, we should also keep in mind that blood pressure levels have remained central to the primary and secondary prevention of blood pressure-related cardiovascular diseases in clinical practice.

  15. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    OpenAIRE

    Daniel D. Reidpath; Mei Lee Ling; Shajahan Yasin; Kanason Rajagobal; Pascale Allotey

    2012-01-01

    Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers usin...

  16. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Blood Pressure Test

    Science.gov (United States)

    ... pressure monitors may have some limitations. Tracking your blood pressure readings It can be helpful in diagnosing or ... more Stage 2 high blood pressure (hypertension) Elevated blood pressure and stages 1 and 2 high blood pressure ( ...

  18. Validation of the Microlife WatchBP Home blood pressure device in pregnancy for medium and large arm circumferences.

    Science.gov (United States)

    Clark, Katherine; Snowball, Olivia; Nzelu, Diane; Kay, Polly; Kametas, Nikos A

    2018-06-01

    The Microlife WatchBP Home automated blood pressure device was assessed for accuracy in pregnant women of medium (arm circumference. The British Hypertension Society validation protocol was modified for the purpose of this study to include women with arm circumference of less than 32 cm (N=51) and greater than or equal to 32 cm (N=46) as two separate arms. The device achieved an overall A/A grade for medium arm circumference and B/A grade for large arm circumference. The mean±SD device-observer difference was 1.7±6.2 and -0.4±4.4 for systolic and diastolic blood pressure, respectively, for medium arm circumference and 3.0±8.5 and 1.5±5.1, respectively, for large arm circumference. When all women with pre-eclampsia from both groups were pooled (N=23), the device achieved an overall grade of A/A with mean differences of 2.1±7.2 for systolic blood pressure and 1.0±5.6 for diastolic blood pressure. The Microlife WatchBP Home automated blood pressure device can be recommended for use in pregnant women of all gestations, including those with pre-eclampsia. However, caution is needed for women with large arm circumferences.

  19. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  20. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Chin, K Y; Panerai, R B

    2013-01-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SD d ) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  1. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  2. Low Blood Pressure

    Science.gov (United States)

    ... a problem. Sometimes blood pressure that is too low can also cause problems. Blood pressure is the ... reading is 90/60 or lower, you have low blood pressure. Some people have low blood pressure ...

  3. Low Blood Pressure (Hypotension)

    Science.gov (United States)

    ... lowest at night and rises sharply on waking. Blood pressure: How low can you go? What's considered low ... low blood pressure. Medications that can cause low blood pressure Some medications can cause low blood pressure, including: ...

  4. A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study.

    Science.gov (United States)

    Schoot, Tessa S; Weenk, Mariska; van de Belt, Tom H; Engelen, Lucien J L P G; van Goor, Harry; Bredie, Sebastian J H

    2016-05-05

    Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP self-measurement. The objective of our study was to evaluate the performance of the first release of the Checkme Health Monitor (Viatom Technology), a cuffless BP monitor, in a real-life setting. Furthermore, we wanted to investigate whether the posture of the volunteer and the position of the device relative to the heart level would influence its outcomes. Study volunteers fell into 3 BP ranges: high (>160 mmHg), normal (130-160 mmHg), and low (measurements were met according to the European Society of Hypertension International Protocol (ESH-IP) for the validation of BP measurement devices. After calibrating the Checkme device, we measured systolic BP with Checkme and a validated, oscillometric reference BP monitor (RM). Measurements were performed in randomized order both in supine and in sitting position, and with Checkme at and above heart level. We recruited 52 volunteers, of whom we excluded 15 (12 due to calibration failure with Checkme, 3 due to a variety of reasons). The remaining 37 volunteers were divided into low (n=14), medium (n=13), and high (n=10) BP ranges. There were 18 men and 19 women, with a mean age of 54.1 (SD 14.5) years, and mean recruitment systolic BP of 141.7 (SD 24.7) mmHg. BP results obtained by RM and Checkme correlated well. In the supine position, the difference between the RM and Checkme was >5 mmHg in 17 of 37 volunteers (46%), of whom 9 of 37 (24%) had a difference >10 mmHg and 5 of 37 (14%) had a difference >15 mmHg. BP obtained with Checkme correlated well with RM BP, particularly in the position (supine) in which the device was calibrated. These preliminary results are promising for conducting further research on cuffless BP measurement in the

  5. Smart blood pressure holter.

    Science.gov (United States)

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  6. High Blood Pressure

    Science.gov (United States)

    ... normal blood pressure 140/90 or higher is high blood pressure Between 120 and 139 for the top number, ... prehypertension. Prehypertension means you may end up with high blood pressure, unless you take steps to prevent it. High ...

  7. High Blood Pressure Facts

    Science.gov (United States)

    ... Stroke Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN High Blood Pressure Facts Recommend on Facebook Tweet Share Compartir On ... Top of Page CDC Fact Sheets Related to High Blood Pressure High Blood Pressure Pulmonary Hypertension Heart Disease Signs ...

  8. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... Print Page Text Size: A A A Listen High Blood Pressure (Hypertension) Nearly 1 in 3 American adults has ... weight. How Will I Know if I Have High Blood Pressure? High blood pressure is a silent problem — you ...

  9. Ambulatory heart rate is underestimated when measured by an Ambulatory Blood Pressure device

    NARCIS (Netherlands)

    Vrijkotte, T.G.M.; de Geus, E.J.C.

    1999-01-01

    Objective: To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Design: Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous

  10. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T. G.; de Geus, E. J.

    2001-01-01

    To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous electrocardiogram (ECG) recordings

  11. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T.G.M.; de Geus, E.J.C.

    2001-01-01

    Objective: To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Design: Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous

  12. What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?

    Science.gov (United States)

    Eguchi, Kazuo; Kuruvilla, Sujith; Ogedegbe, Gbenga; Gerin, William; Schwartz, Joseph E; Pickering, Thomas G

    2009-06-01

    To clarify whether a shorter interval between three successive home blood pressure (HBP) readings (10 s vs. 1 min) taken twice a day gives a better prediction of the average 24-h BP and better patient compliance. We enrolled 56 patients from a hypertension clinic (mean age: 60 +/- 14 years; 54% female patients). The study consisted of three clinic visits, with two 4-week periods of self-monitoring of HBP between them, and a 24-h ambulatory BP monitoring at the second visit. Using a crossover design, with order randomized, the oscillometric HBP device (HEM-5001) could be programmed to take three consecutive readings at either 10-s or 1-min intervals, each of which was done for 4 weeks. Patients were asked to measure three HBP readings in the morning and evening. All the readings were stored in the memory of the monitors. The analyses were performed using the second-third HBP readings. The average systolic BP/diastolic BP for the 10-s and 1-min intervals at home were 136.1 +/- 15.8/77.5 +/- 9.5 and 133.2 +/- 15.5/76.9 +/- 9.3 mmHg (P = 0.001/0.19 for the differences in systolic BP and diastolic BP), respectively. The 1-min BP readings were significantly closer to the average of awake ambulatory BP (131 +/- 14/79 +/- 10 mmHg) than the 10-s interval readings. There was no significant difference in patients' compliance in taking adequate numbers of readings at the different time intervals. The 1-min interval between HBP readings gave a closer agreement with the daytime average BP than the 10-s interval.

  13. Validation of the Omron MIT Elite blood pressure device in a pregnant population with large arm circumference.

    Science.gov (United States)

    James, Lauren; Nzelu, Diane; Hay, Anna; Shennan, Andrew; Kametas, Nikos A

    2017-04-01

    The aim of this study was to evaluate the accuracy of the Omron MIT Elite automated device in pregnant women with an arm circumference of or above 32 cm, using the British Hypertension Society validation protocol. Blood pressure was measured sequentially in 46 women of any gestation requiring the use of a large cuff (arm circumference ≥32 cm) alternating between the mercury sphygmomanometer and the Omron MIT Elite device. The Omron MIT Elite achieved an overall D/D grade with a mean of the device-observer difference being 7.17±6.67 and 9.31±6.59 for systolic and diastolic blood pressure respectively. Interobserver accuracy was 94.6% for systolic and 95% for diastolic readings within 5 mmHg. The Omron MIT Elite overestimates blood pressure and has failed the British Hypertension Society protocol requirements. Therefore, it cannot be recommended for use in pregnant women with an arm circumference of or above 32 cm.

  14. Hypertension (High Blood Pressure)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Hypertension (High Blood Pressure) KidsHealth / For Teens / Hypertension (High Blood Pressure) What's ... rest temperature diet emotions posture medicines Why Is High Blood Pressure Bad? High blood pressure means a person's heart ...

  15. Blood Pressure Medicines

    Science.gov (United States)

    High blood pressure, also called hypertension, usually has no symptoms. But it can cause serious problems such as stroke, heart ... kidney failure. If you cannot control your high blood pressure through lifestyle changes such as losing weight and ...

  16. High blood pressure - children

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007696.htm High blood pressure - children To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  17. Preventing High Blood Pressure

    Science.gov (United States)

    ... Heart Disease Cholesterol Salt Million Hearts® WISEWOMAN Preventing High Blood Pressure: Healthy Living Habits Recommend on Facebook Tweet Share ... meal and snack options can help you avoid high blood pressure and its complications. Be sure to eat plenty ...

  18. High blood pressure - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007329.htm High blood pressure - infants To use the sharing features on this page, please enable JavaScript. High blood pressure (hypertension) is an increase in the force of ...

  19. High blood pressure medications

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007484.htm High blood pressure medicines To use the sharing features on this page, please enable JavaScript. Treating high blood pressure will help prevent problems such as heart disease, ...

  20. 21 CFR 870.1100 - Blood pressure alarm.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure alarm. 870.1100 Section 870.1100...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1100 Blood pressure alarm. (a) Identification. A blood pressure alarm is a device that accepts the signal from a blood pressure...

  1. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol.

    Science.gov (United States)

    Altunkan, Sekip; Ilman, Nevzat; Altunkan, Erkan

    2007-04-01

    A variety of automatic blood measurement devices with diverse features have been introduced to the medical markets recently. Among these devices, models that measure at the wrist have become increasingly popular in self measurements. The objective of this study was to evaluate the accuracy of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure devices against the mercury sphygmomanometer in adults according to the International Protocol criteria. Fifty-four patients over 30 years of age were studied and classified based on the International Protocol range. Blood pressure measurements at the wrist with the Samsung SBM-100A and Microlife BP 3BU1-5 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential blood pressure measurements were taken. A total of 33 participants with randomly distributed arm circumferences were selected for both of the validation studies. During each validation study, 99 measurements were obtained for comparison from 33 participants. The first phase was performed on 15 participants and if the device passed this phase, 18 more participants were selected. Mean discrepancies and standard deviations of the device-sphygmomanometer were 0.9+/-9.2 and -2.7+/-9.3 mmHg for systolic blood pressure and -1.4+/-8.0 mmHg and 1.4+/-5.7 for diastolic blood pressure in the Samsung and Microlife study groups, respectively. The Samsung SBM-100A passed Phase 1 in 15 participants. Despite the fact that Microlife BP 3BU1-5 passed Phase 1 for diastolic pressure, it failed according to the systolic pressure criteria. Eighteen patients were added and Phase 2 was continued, in which Samsung SBM-100A failed to meet the criteria of Phases 2.1 and 2.2 for adults in systolic and diastolic blood pressure. It was found that the Microlife BP 3BU1-5 does not meet the criteria of either of Phases 2.1 and 2.2 for systolic blood pressure and Phase 2.2 for diastolic blood pressure. In this study, Samsung SBM

  2. Understanding Blood Pressure Readings

    Science.gov (United States)

    ... Venous Thromboembolism Aortic Aneurysm More Understanding Blood Pressure Readings Updated:Jun 1,2018 What do your blood ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, ...

  3. Can validated wrist devices with position sensors replace arm devices for self-home blood pressure monitoring? A randomized crossover trial using ambulatory monitoring as reference.

    Science.gov (United States)

    Stergiou, George S; Christodoulakis, George R; Nasothimiou, Efthimia G; Giovas, Periklis P; Kalogeropoulos, Petros G

    2008-07-01

    Electronic devices that measure blood pressure (BP) at the arm level are regarded as more accurate than wrist devices and are preferred for home BP (HBP) monitoring. Recently, wrist devices with position sensors have been successfully validated using established protocols. This study assessed whether HBP values measured with validated wrist devices are sufficiently reliable to be used for making patient-related decisions in clinical practice. This randomized crossover study compared HBP measurements taken using validated wrist devices (wrist-HBP, Omron R7 with position sensor) with those taken using arm devices (arm-HBP, Omron 705IT), and also with measurements of awake ambulatory BP (ABP, SpaceLabs), in 79 subjects (36 men and 43 women) with hypertension. The mean age of the study population was 56.7 +/- 11.8 years, and 33 of the subjects were not under treatment for hypertension. The average arm-HBP was higher than the average wrist-HBP (mean difference, systolic 5.2 +/- 9.1 mm Hg, P or =10 mm Hg difference between systolic wrist-HBP and arm-HBP and twelve subjects (15%) showed similar levels of disparity in diastolic HBP readings. Strong correlations were found between arm-HBP and wrist-HBP (r 0.74/0.74, systolic/diastolic, P arm-HBP (r 0.73/0.76) than with wrist-HBP (0.55/0.69). The wrist-arm HBP difference was associated with systolic ABP (r 0.34) and pulse pressure (r 0.29), but not with diastolic ABP, sex, age, arm circumference, and wrist circumference. There might be important differences in HBP measured using validated wrist devices with position sensor vs. arm devices, and these could impact decisions relating to the patient in clinical practice. Measurements taken using arm devices are more closely related to ABP values than those recorded by wrist devices. More research is needed before recommending the widespread use of wrist monitors in clinical practice. American Journal of Hypertension doi:10.1038/ajh.2008.176American Journal of Hypertension (2008

  4. High blood pressure - adults

    Science.gov (United States)

    ... pressure is found. This is called essential hypertension. High blood pressure that is caused by another medical condition or medicine you are taking is called secondary hypertension. Secondary hypertension may be due to: Chronic ...

  5. Validation of Omron RS8, RS6, and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Takahashi, Hakuo; Yoshika, Masamichi; Yokoi, Toyohiko

    2013-01-01

    Allowing patients to measure their blood pressure at home is recognized as being of clinical value. However, it is not known how often these measurements are taken correctly. Blood pressure monitors for home use fall into two types based on the position of the cuff, ie, at the upper arm or the wrist. The latter is particularly convenient, as measurements can be taken fully clothed. This study aimed to evaluate the performance of the wrist-type blood pressure monitors Omron RS8 (HEM-6310F-E), Omron RS6 (HEM-6221-E), and Omron RS3 (HEM-6130-E). A team of three trained doctors validated the performance of these devices by comparing the measurements obtained from these devices with those taken using a standard mercury sphygmomanometer. All the devices met the validation requirements of the European Society of Hypertension International Protocol revision 2010. The difference in blood pressure readings between the tested device and the standard mercury sphygmomanometer was within 3 mmHg, which is acceptable according to the European Society of Hypertension guidelines. All the home devices tested were found to be suitable for measuring blood pressure at home because their performance fulfilled the requirement of the guidelines.

  6. Comparison of an implantable telemetry device and an oscillometric monitor for measurement of blood pressure in anaesthetized and unrestrained green iguanas (Iguana iguana).

    Science.gov (United States)

    Chinnadurai, Sathya K; DeVoe, Ryan; Koenig, Amie; Gadsen, Nadia; Ardente, Amanda; Divers, Stephen J

    2010-09-01

    The objective of this study was to compare an implanted direct blood pressure monitor and a non-invasive oscillometric unit for use in anesthetized and awake green iguanas. Prospective experimental trial. Four male and four female adult green iguanas (Iguana iguana) weighing 1833 +/- 534 g. For each animal, the carotid artery was surgically exposed and the catheter tip of the pressure transducer was placed in the aortic arch. Non-invasive blood pressure was measured using a cuff over the left femoral region. Pulse rate, respiratory rate and arterial blood pressure (ABP) measurements were taken every 5 minutes. Direct ABP measurements consisted of recording numerical values and graphic output. Simultaneous direct and indirect measurements were repeated in awake animals. The oscillometric device failed to provide a reading in over 80% of attempts, and failed to provide readings that correlated with direct measurements. The implanted direct transducer was capable of detecting blood pressures throughout all ABP ranges examined. The implantable transducer was a reliable means of determining blood pressure in this study, while the oscillometric device was unreliable and often failed to provide any reading. We do not recommend using the oscillometric device as described in a research or clinical setting for green iguanas. The advantages of an implantable device include the ability to monitor awake and anesthetized subjects remotely and continuously. These monitors are small, biocompatible and function across a wide range of ABP.

  7. The Impact of Hearing Protection Devices (HPDs on Blood Pressure in Workers Exposed to Noise: A Cross-sectional Study in a Textile Industry

    Directory of Open Access Journals (Sweden)

    Jafar Akbari

    2018-06-01

    Full Text Available Many studies have reported that exposure to workplace noise leads to increase in blood pressure. The aim of this study was to investigate the effect of hearing protection devices (HPDs including ear plug and ear muff on the systolic and diastolic blood pressures of workers exposed to workplace noise in a textile industry. A total of 120 male workers that exposed to 95 dB noise were investigated in this study. The systolic and diastolic blood pressures of the workers were measured for three situations of earplug, earmuff and earplug along earmuff applications. Data analyses were conducted through SPSS software (version 20 and statistical tests of ANOVA and Independent Sample Tests. The comparison of mean blood pressure in three situations showed that using ear muff had a significant effect on the systolic and diastolic blood pressures in the workers. Furthermore, the use of ear plug only had an effect on the systolic blood pressure. But, the application of ear muff caused to decrease in the systolic and diastolic blood pressures only in the third stage of the study. With regard to the results in this study, in order to control the blood pressure changes of the workers, it is recommended to use ear muff in the textile industry.

  8. High Blood Pressure (Hypertension)

    Science.gov (United States)

    ... other risk factors, like diabetes, you may need treatment. How does high blood pressure affect pregnant women? A few women will get ... HIV, Birth Control Heart Health for Women Pregnancy Menopause More Women's Health ... High Blood Pressure--Medicines to Help You Women and Diabetes Heart ...

  9. The impact of arm position and pulse pressure on the validation of a wrist-cuff blood pressure measurement device in a high risk population

    Directory of Open Access Journals (Sweden)

    Ali Reza Khoshdel

    2010-03-01

    Full Text Available Ali Reza Khoshdel1,2, Shane Carney2, Alastair Gillies21Faculty of Medicine, Aja University of Medical Science, Tehran, Iran; 2John Hunter Hospital, Faculty of Health, The University of Newcastle, Newcastle, NS W, AustraliaAbstract: Despite the increasing popularity of blood pressure (BP wrist monitors for self-BP measurement at home, device validation and the effect of arm position remains an issue. This study focused on the validation of the Omron HEM-609 wrist BP device, including an evaluation of the impact of arm position and pulse pressure on BP measurement validation. Fifty patients at high risk for cardiovascular disease were selected (age 65 ± 10 years. Each patient had two measurements with a mercury sphygmomanometer and three measurements with the wrist BP device (wrist at the heart level while the horizontal arm supported [HORIZONTAL], hand supported on the opposite shoulder [SHOULDER], and elbow placed on a desk [DESK], in random order. The achieved systolic BP (SBP and diastolic BP (DBP wrist-cuff readings were compared to the mercury device and the frequencies of the readings within 5, 10, and 15 mmHg of the gold standard were computed and compared with the British Hypertension Society (BHS and Association for the Advancement of Medical Instrumentation (AAMI protocols. The results showed while SBP readings with HORIZONTAL and SHOULDER positions were significantly different from the mercury device (mean difference = 7.1 and 13.3 mmHg, respectively; P < 0.05, the DESK position created the closest reading to mercury (mean difference = 3.8, P > 0.1. Approximately 71% of SBP readings with the DESK position were within ±10 mmHg, whereas it was 62.5% and 34% for HORIZONTAL and SHOULDER positions, respectively. Wrist DBP attained category D with BHS criteria with all three arm positions. Bland–Altman plots illustrated that the wrist monitor systematically underestimated SBP and DBP values. However a reading adjustment of 5 and 10 mm

  10. 21 CFR 870.1120 - Blood pressure cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure cuff. 870.1120 Section 870.1120...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic...

  11. High Blood Pressure

    Science.gov (United States)

    ... kidney disease, diabetes, or metabolic syndrome Read less Unhealthy lifestyle habits Unhealthy lifestyle habits can increase the risk of high blood pressure. These habits include: Unhealthy eating patterns, such as eating too much sodium ...

  12. High Blood Pressure

    Science.gov (United States)

    ... factors Diabetes High blood pressure Family history Obesity Race/ethnicity Full list of causes and risk factors ... give Give monthly Memorials and tributes Donate a car Donate gently used items Stock donation Workplace giving ...

  13. Effect of device-guided breathing exercises on blood pressure in hypertensive patients with type 2 diabetes mellitus : A randomized controlled trial

    NARCIS (Netherlands)

    Logtenberg, Susan J.; Kleefstra, Nanne; Houweling, Sebastlaan T.; Groenier, Klaas H.; Bilo, Henk J.

    Objective In patients with type 2 diabetes mellitus (DM2), it is hard to reach treatment objectives for blood pressure (BP) with classical treatment options. Recently, reducing breathing frequency has been advocated as a method to reduce BP. We examined if an electronic device such as Resperate, by

  14. Pressure suppression device

    International Nuclear Information System (INIS)

    Mizumachi, Wataru; Fukuda, Akira; Kitaguchi, Hidemi; Shimizu, Toshiaki.

    1976-01-01

    Object: To relieve and absorb impact wave vibrations caused by steam and non-condensed gases releasing into the pressure suppression chamber at the time of an accident. Structure: The reactor container is filled with inert gases. A safety valve attached main steam pipe is provided to permit the excessive steam to escape, the valve being communicated with the pressure suppression chamber through an exhaust pipe. In the pressure suppression chamber, a doughnut-like cylindrical outer wall is filled at its bottom with pool water to condense the high temperature vapor released through the exhaust pipe. A head portion of a vent tube which leads the exhaust pipe is positioned at the top, and a down comer and an exhaust vent tube are locked by means of steady rests. At the bottom is mounted a pressure adsorber device which adsorbs a pressure from the pool water. (Kamimura, M.)

  15. Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Bramlage, Peter; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Zwingers, Thomas; Beime, Beate; Mengden, Thomas

    2014-01-01

    The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measured in 33 adult subjects (13 males and 20 females) and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was -0.5±4.5 mmHg for SBP and -0.1±3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP. The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010.

  16. Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010

    Directory of Open Access Journals (Sweden)

    Bramlage P

    2014-05-01

    Full Text Available Peter Bramlage,1 Cornelia Deutsch,1 Ralf Krüger,1 Andreas Wolf,2 Peter Müller,2 Thomas Zwingers,1,4 Beate Beime,1 Thomas Mengden31Institut für Pharmakologie und Präventive Medizin, Cloppenburg, 2Müller and Sebastiani, Ottobrunn, 3Kerckhoff-Klinik, Bad Nauheim, 4Estimate, Augsburg, GermanyObjective: The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP. The device can be used for ABPM for up to 72 hours.Materials and methods: Systolic and diastolic blood pressure (SBP and DBP, respectively were sequentially measured in 33 adult subjects (13 males and 20 females and compared with a standard mercury sphygmomanometer (two observers. A total of 99 comparison pairs were obtained.Results: The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was −0.5±4.5 mmHg for SBP and −0.1±3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP.Conclusion: The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010.Keywords: validation, ambulatory blood pressure monitoring, ESH

  17. [Validation of the Omron HEM-650 wrist blood pressure device using the British Hypertension Society protocol in emergency patients in Hong Kong].

    Science.gov (United States)

    Hung, Kevin KC; Lai, W Y; Cocks, Robert A; Rainer, Timothy H; Graham, Colin A

    2015-10-01

    Automated wrist cuff blood pressure (BP) devices are more compact and easier to use, particularly when access to the upper arm is restricted, for example in emergencies. We tested the Omron HEM-650 wrist device using the validation criteria of the British Hypertension Society (BHS) protocol in a major emergency department (ED) in Hong Kong. 85 patients had three measurements each by both the Omron HEM-650 wrist device and the mercury sphygmomanometer. The conventional automated BP with arm cuff was also measured using an oscillometric (Colin BP-88S NXT) device for comparison. The Omron HEM-650 achieved a grade B for both systolic and diastolic BP and demonstrated acceptable accuracy and reliability in Chinese patients in the emergency setting. The Omron HEM 650 wrist device can be recommended for use in adult emergency patients. Further research is warranted for its use in pregnant women and critically ill patients.

  18. Pressure suppression device

    International Nuclear Information System (INIS)

    Yoshida, Toyokazu.

    1976-01-01

    Purpose: To provide a pressure suppression device for a gas cooled reactor wherein the coolant is discharged in a reactor building by a loss-of-coolant accident or the like, the increase in the pressure and temperature is controlled and thermal energy of the discharged coolant of high temperature and high pressure can be absorbed. Constitution: A low heat source unit is provided at the upper part in an inner space of a reactor building provided around the reactor, and at the upper part of the low heat source unit a stirring fan for mixing gas within the building, and a low heat source circulating the low heat source through a pipe is connected to the low heat source unit. The low heat source unit is provided with the pipe arranged in a spiral shape at the upper part of the space of the unit, and a large number of fins are provided at the outer surface of the pipe for increasing the transmission area and improve the heat exchange. When the coolant of high temperature and high pressure has been lost in the building, the thermal energy of the coolant is absorbed by the low heat source unit. (Aizawa, K.)

  19. Pressure detection device

    International Nuclear Information System (INIS)

    Fuji, Akira.

    1997-01-01

    The present invention provides a pressure detection device having a function of preventing discharge of reactor water in pipelines to the outside of a system when a pipeline for detecting pressure to be connected to a reactor is failed. Namely, a fluid pressure detector is disposed at the downstream of the detection pipeline. A cylindrical member having a shrinkable inner diameter is disposed to the outer circumference at the upstream. A cylindrical member having an outer diameter substantially equal to the inner diameter of the detection pipeline is disposed while restricting the movement of the detection pipeline in the inner circumferential direction. Then, it fasten the detection pipeline from the outside upon failure of the pipeline thereby enabling to suppress the flow rate of the fluid in the detection pipeline. In addition, a shape memory alloy which shrinks upon elevation of temperature is used for the cylindrical member. Then, the discharge of the fluid can be prevented automatically upon rupture of the pipeline. (I.S.)

  20. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  1. Blood pressure monitors for home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... may ask you to keep track of your blood pressure at home. To do this, you will need ...

  2. Common High Blood Pressure Myths

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Common High Blood Pressure Myths Updated:May 4,2018 Knowing the facts ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  3. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  4. High Blood Pressure in Pregnancy

    Science.gov (United States)

    ... of the baby. Controlling your blood pressure during pregnancy and getting regular prenatal care are important for ... your baby. Treatments for high blood pressure in pregnancy may include close monitoring of the baby, lifestyle ...

  5. Medications for High Blood Pressure

    Science.gov (United States)

    ... Consumers Home For Consumers Consumer Updates Medications for High Blood Pressure Share Tweet Linkedin Pin it More sharing options ... age and you cannot tell if you have high blood pressure by the way you feel, so have your ...

  6. High blood pressure and diet

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007483.htm High blood pressure and diet To use the sharing features on ... diet is a proven way to help control high blood pressure . These changes can also help you lose weight ...

  7. Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Zimmermann, Erik; Bramlage, Peter

    2016-12-01

    The aim of the present study was to validate the blood pressure (BP) measurement device Erkameter 125 PRO according to the International Protocol revision 2010 of the European Society of Hypertension (ESH-IP2). In 33 patients aged 32-79 years, BP measurements were performed alternately using the Erkameter 125 PRO and the reference mercury sphygmomanometer according to ESH-IP revision 2010. For the analysis, a total of 99 comparisons were included. All absolute differences between the test device and the reference were within 10 mmHg for systolic blood pressure (SBP), and all except one for diastolic blood pressure (DBP). A total of 93 out of 99 comparisons for SBP showed an absolute difference within 5 mmHg and 92 out of 99 for DBP. The mean±SD difference between the Erkameter 125 PRO and the standard reference was -0.5±3.5 mmHg for SBP and 0.5±3.5 mmHg for DBP. As to part 2 of ESH-IP 2010, all patients had a minimum of two out of three measurements within 5 mmHg difference for SBP and 31 out of 33 patients for DBP. The Erkameter 125 PRO fulfilled the requirements of parts 1 and 2 of the ESH-IP revision 2010 and can be recommended for office BP measurements in adults.

  8. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT).

    Science.gov (United States)

    Topouchian, Jirar A; El Assaad, Mohamed A; Orobinskaia, Ludmila V; El Feghali, Ramzi N; Asmar, Roland G

    2006-06-01

    Two electronic devices for self-measurement of blood pressure - a brachial monitor, the Omron M6, and a wrist monitor, the Omron R7 - were evaluated in two separate studies according to the International Protocol of the European Society of Hypertension. The International Validation Protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood pressure measurements) making a total number of 33 participants (99 pairs of blood pressure measurements) on whom the final validation is performed. The same methodology recommended by the European Society of Hypertension protocol was applied for both studies. In each study and for each participant, four blood pressure measurements were taken simultaneously by two trained observers using mercury sphygmomanometers alternately with three measurements taken by the tested device. The difference between the blood pressure value given by the device and that obtained by the two observers (mean of the two observers) was calculated for each measure. The 99 pairs of blood pressure differences were classified into three categories (M6 device, and 0.2+/-4.2 and 0.2+/-2.9 mmHg for systolic and diastolic blood pressure, respectively, for the Omron R7 device. For both devices, readings differing by less than 5, 10 and 15 mmHg for systolic and diastolic blood pressure values fulfill the recommendation criteria of the International Protocol as well as the individual analysis. The Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT) devices fulfilled the validation recommendations of the International Protocol.

  9. Types of Blood Pressure Medications

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Types of Blood Pressure Medications Updated:Nov 6,2017 Prescription blood pressure ... This content was last reviewed October 2017. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  10. Controlling your high blood pressure

    Science.gov (United States)

    ... medlineplus.gov/ency/patientinstructions/000101.htm Controlling your high blood pressure To use the sharing features on this page, ... JavaScript. Hypertension is another term used to describe high blood pressure. High blood pressure can lead to: Stroke Heart ...

  11. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  12. ORANGE JUICE AND BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    M. F. VALIM

    2009-01-01

    Full Text Available

    Blood pressure is the force of blood against artery walls. It is measured in millimeters of mercury (mm Hg and recorded as two numbers: systolic pressure (as the heart contracts over diastolic pressure (as the heart relaxes between beats. High blood pressure (hypertension is defined as chronically elevated high blood pressure, with systolic blood pressure (SBP of 140 mm Hg or greater, and diastolic blood pressure (DBP of 90 mm Hg or greater. High blood pressure (HBP, smoking, abnormal blood lipid levels, obesity and diabetes are risk factors for coronary heart disease, the leading cause of death in the US. Lifestyle modifications such as engaging in regular physical activity, quitting smoking and eating a healthy diet (limiting intake of saturated fat and sodium and increasing consumption of fiber, fruits and vegetables are advocated for the prevention, treatment, and control of HBP. As multiple factors influence blood pressure, the effects of each factor are typically modest, particularly in normotensive subjects, yet the combined effects can be substantial. Nutrition plays an important role in influencing blood pressure. Orange juice should be included as part of any low sodium diet and/or any blood pressure reducing eating plan, as it is sodium free, fat-free and can help meet recommended levels of potassium intake that may contribute to lower BP.

  13. Assessment of the DIXTAL DX-2710 Automated Oscillometric Device for Blood Pressure Measurement with the Validation Protocols of the British Hypertension Society (BHS and the Association for the Advancement of Medical Instrumentation (AAMI

    Directory of Open Access Journals (Sweden)

    Gisele M. P. Mano

    2002-12-01

    Full Text Available OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years. The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg; and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg. The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

  14. Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo

    2014-02-01

    The objective of this study was to determine the accuracy of the A&D BP UA-651 device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Device evaluation was carried out in 33 patients. The mean age of the patients was 48.3±15.5 years, the mean systolic BP was 138.3±24.9 mmHg (range 90-180), the mean diastolic BP was 88.3±13.8 mmHg (range 60-108), and the mean arm circumference was 28.6±3.4 cm (range 23-36). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device underestimated the systolic BP by 0.4±4.4 mmHg and diastolic BP by 1.3±3.5 mmHg. The device-observer discrepancies were unrelated to patients' clinical characteristics. These data show that the A&D BP UA-651 device fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  15. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  16. Improving the accuracy of blood pressure measurement: the influence of the European Society of Hypertension International Protocol (ESH-IP) for the validation of blood pressure measuring devices and future perspectives.

    Science.gov (United States)

    Stergiou, George S; Asmar, Roland; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Shennan, Andrew; Wang, Jiguang; O'Brien, Eoin

    2018-03-01

    The European Society of Hypertension (ESH) International Protocol (ESH-IP) for the validation of blood pressure (BP) measuring devices was published in 2002, with the main objective of simplifying the validation procedures, so that more BP monitors would be subjected to independent validation. This article provides an overview of the international impact of the ESH-IP and of the lessons learned from its use, to be able to justify further developments in validation protocols. A review of published (PubMed) validation studies from 2002 to 2017 was performed. One hundred and seventy-seven validation studies using the ESH-IP, 59 using the British Hypertension Society protocol, 46 using the Association for the Advancement of Medical Instrumentation (AAMI) standard and 23 using the International Organization for Standardization (ISO) standard were identified. Lists of validated office-clinic, home and ambulatory BP monitors are provided. Of the ESH-IP studies, 93% tested oscillometric devices, 80% upper arm, 71% home, 25% office and 7% ambulatory monitors (some had more than one function). The original goal of the ESH-IP has been fulfilled in that in the last decade the number of published validation studies has more than doubled. It is now recognized that the provision of accurate devices would be best served by having a universal protocol. An international initiative has been put in place by AAMI, ESH and ISO experts aiming to reach consensus for a universal validation protocol to be accepted worldwide, which will allow a more thorough evaluation of the accuracy and performance of future BP monitors.

  17. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... are below 100 mg/dL before meals and fasting and are less than 140 mg/dL two hours after meals. People with diabetes should consult their doctor or health care provider to set appropriate blood glucose goals. ...

  18. New centrifugation blood culture device.

    Science.gov (United States)

    Dorn, G L; Smith, K

    1978-01-01

    A single-tube blood culture device designed for centrifugation in a tabletop centrifuge is described. Reconstruction experiments using 21 different organisms and human donor blood indicate that excellent recovery can be obtained by centrifugation for 30 min at 3,000 X g. PMID:342539

  19. Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension

    Directory of Open Access Journals (Sweden)

    Asmar R

    2011-11-01

    Full Text Available Jirar Topouchian1, Davide Agnoletti1, Jacques Blacher1, Ahmed Youssef1, Isabel Ibanez2,3, Jose Khabouth2, Salwa Khawaja2, Layale Beaino2, Roland Asmar1–31Centre de Diagnostic, Hôpital Hôtel-Dieu, Paris, France; 2Hôpital Libanais and Faculté Libanaise de Médecine, Beirut, Lebanon; 3Foundation-Medical Research Institutes, Geneva, SwitzerlandBackground: Four oscillometric devices for self-measurement of blood pressure (SBPM were evaluated according to the European Society of Hypertension (ESH international protocol and its 2010 revision in four separate studies. The Omron® M2, Omron M3, and Omron M6 measure blood pressure (BP at the brachial level, while the Omron R2 measures BP at the wrist level.Methods: The international protocol requires a total number of 33 subjects in which the validation is performed. The Omron M2 and Omron R2 were validated in 2009 according to the ESH international protocol, while the Omron M3 and Omron M6 were validated in 2010–2011 according to the 2010 ESH international protocol revision. The protocol procedures were followed precisely.Results: All four tested devices passed the validation process. The mean differences between the device and mercury readings were 2.7 ± 5.0 and –1.4 ± 3.2 mmHg for systolic and diastolic BP, respectively, using the Omron M2 device, and 1.7 ± 3.2 and –0.9 ± 2.6 mmHg using the Omron M3, 1.6 ± 2.9 and -0.9 ± 2.5 mmHg using the Omron M6, and –1.1 ± 4.8 and –0.9 ± 4.3 mmHg using the Omron R2.Conclusion: Readings from the Omron M2, Omron M3, Omron M6, and Omron R2, differing by less than 5, 10, and 15 mmHg, fulfill the ESH international protocol and its 2010 revision requirements. Therefore, each of these four devices can be used by patients for SBPM.Keywords: Omron R2, M2, M3, M6, blood pressure measurement, validation, international protocol, European Society of Hypertension

  20. Validation of the A&D BP UB-542 wrist device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Saladini, Francesca; Benetti, Elisabetta; Fania, Claudio; Palatini, Paolo

    2013-08-01

    The objective of this study was to determine the accuracy of the A&D BP UB-542 wrist device for home blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension (ESH). Device evaluation was carried out in 33 patients. The mean age was 50.9±10.1 years, the mean systolic BP was 141.6±22.8 mmHg (range 92 : 189), the mean diastolic BP was 89.2±11.4 mmHg (range 62 : 120), the mean arm circumference was 28.8±3.2 cm (range 23-35), and the mean wrist circumference was 17.1±1.4 cm (range 14-19.5). The protocol requirements were followed precisely. The device passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated the systolic BP by 1.8±7.2 mmHg and diastolic BP by 1.6±5.7 mmHg. These data show that the A&D BP UB-542 wrist device met the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  1. Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension.

    Science.gov (United States)

    El Feghali, Ramzi N; Topouchian, Jirar A; Pannier, Bruno M; El Assaad, Hiba A; Asmar, Roland G

    2007-06-01

    A high percentage of hypertensive patients present an arm circumference of over 32 cm; the use of a large cuff is therefore recommended. Validation studies are usually performed in the general population using a standard-size cuff. The aim of this study was to assess the accuracy of the Omron M7 device in a population with an arm circumference ranging from 32 to 42 cm. A validation study was performed according to the International Protocol of the European Society of Hypertension. This protocol is divided into two phases: the first phase is performed on 15 selected participants (45 pairs of blood-pressure measurements); if the device passes this phase, 18 supplementary participants are included (54 pairs of blood-pressure measurements), making a total number of 33 participants (99 pairs of blood-pressure measurements), on whom the analysis is performed. For each participant, four blood-pressure measurements were performed simultaneously by two trained observers, using mercury sphygmomanometers fitted with a Y tube; the measurements alternated with three by the test device. The difference between the blood-pressure value given by the device and that obtained by the two observers (mean of the two observations) was calculated for each measure. The 99 pairs of blood-pressure differences were classified into three categories (Society of Hypertension protocol. The Omron M7 device passed the first and the second phases of the validation process. The average differences between the two observers were 1.5+/-3.2 and -0.5+/-2.2 mmHg for systolic blood pressure and diastolic blood pressure, and those between the device and the mercury sphygmomanometer were -1.6+/-6.7 for systolic blood pressure and -0.12+/-4.0 mmHg for diastolic blood pressure Readings that differ by less than 5, 10 and 15 mmHg for systolic blood-pressure and diastolic blood-pressure values fulfill the recommendation criteria of the European Society of Hypertension protocol. The Omron M7 (HEM-780-E) device

  2. Accuracy of the WatchBP office ABI device for office blood pressure measurement over a wide range of arm sizes.

    Science.gov (United States)

    Palatini, Paolo; Fania, Claudio; Gasparotti, Federica

    2018-04-01

    The aim of this study was to determine the accuracy of the WatchBP Office ABI monitor for office blood pressure measurement over a wide range of arm circumferences using the ANSI/AAMI/ISO 81060-2:2013 protocol. The device accuracy was tested in 88 participants whose mean±SD age was 54.5±17.6 years, whose arm circumference was 30.6±8.3 cm (range: 15-46 cm), and whose entry blood pressure (BP) was 138.3±23.4 mmHg for systolic and 83.7±14.6 mmHg for diastolic BP. Four cuffs (small, standard, large, and extra-large) suitable for arm circumferences ranging from 14.0 to 52.0 cm were used. The mean device-observer difference in the 264 separate BP data pairs was 0.7±3.8 mmHg for systolic BP and was 0.0±3.7 mmHg for diastolic BP. These data were in agreement with criterion 1 of the ANSI/AAMI/ISO 81060-2:2013 standard requirements (≤5±8 mmHg). Moreover, criterion 2 was satisfied, the mean±SD device-observer difference of the 88 participants being 0.7±3.1 and 0.0±3.2 mmHg, respectively, for systolic and diastolic BP. Good agreement between observer and device was present across the whole range of arm circumferences. These data show that the Microlife WatchBP Office ABI monitor satisfied the ANSI/AAMI/ISO 81060-2:2013 standard requirements across a wide range of arm sizes.

  3. High Blood Pressure (Hypertension) (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Hypertension (High Blood Pressure) KidsHealth / For Parents / Hypertension (High Blood Pressure) What's ... High Blood Pressure) Treated? Print What Is Hypertension (High Blood Pressure)? Blood pressure is the pressure of blood against ...

  4. Pressure suppressing device

    International Nuclear Information System (INIS)

    Naito, Makoto.

    1980-01-01

    Purpose: To prevent the pressure in the reactor container from excessively increasing even when vapor leaks from the dry well to a space of the suppression chamber, without passing though the suppression pool at the time of loss of coolant accident. Constitution: When vapor of a high temperature and a high pressure at the time of loss of coolant accident flows from the dry well to the suppression chamber without passing through suppression pool water, vapor dose not condense with pool water, and therefore the pressure within the chamber abnormally increases. For this reason, this abnormal pressure is detected by a pressure detector thereby to start the operations of a blower and a pump. By starting the blower, the pressure in the dry well becomes lower than the pressure in the chamber, and vapor entirely passes through the pool water and entirely condenses with the pool water. By starting the pump, the pool water is sprayed over the space of the chamber, and vapor in the space is condensed. (Yoshino, Y.)

  5. Validity and reliability of a novel slow cuff-deflation system for noninvasive blood pressure monitoring in patients with continuous-flow left ventricular assist device.

    Science.gov (United States)

    Lanier, Gregg M; Orlanes, Khristine; Hayashi, Yacki; Murphy, Jennifer; Flannery, Margaret; Te-Frey, Rosie; Uriel, Nir; Yuzefpolskaya, Melana; Mancini, Donna M; Naka, Yoshifumi; Takayama, Hiroo; Jorde, Ulrich P; Demmer, Ryan T; Colombo, Paolo C

    2013-09-01

    Doppler ultrasound is the clinical gold standard for noninvasive blood pressure (BP) measurement among continuous-flow left ventricular assist device patients. The relationship of Doppler BP to systolic BP (SBP) and mean arterial pressure (MAP) is uncertain and Doppler measurements require a clinic visit. We studied the relationship between Doppler BP and both arterial-line (A-line) SBP and MAP. Validity and reliability of the Terumo Elemano BP Monitor, a novel slow cuff-deflation device that could potentially be used by patients at home, were assessed. Doppler and Terumo BP measurements were made in triplicate among 60 axial continuous-flow left ventricular assist device (HeartMate II) patients (30 inpatients and 30 outpatients) at 2 separate exams (360 possible measurements). A-line measures were also obtained among inpatients. Mean absolute differences (MADs) and correlations were used to determine within-device reliability (comparison of second and third BP measures) and between-device validity. Bland-Altman plots assessed BP agreement between A-line, Doppler BP, and Terumo Elemano. Success rates for Doppler and Terumo Elemano were 100% and 91%. Terumo Elemano MAD for repeat SBP and MAP were 4.6±0.6 and 4.2±0.6 mm Hg; repeat Doppler BP MAD was 2.9±0.2 mm Hg. Mean Doppler BP was lower than A-line SBP by 4.1 (MAD=6.4±1.4) mm Hg and higher than MAP by 9.5 (MAD=11.0±1.2) mm Hg; Terumo Elemano underestimated A-line SBP by 0.3 (MAD=5.6±0.9) mm Hg and MAP by 1.7 (MAD=6.0±1.0) mm Hg. Doppler BP more closely approximates SBP than MAP. Terumo Elemano was successful, reliable, and valid when compared with A-line and Doppler.

  6. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  7. Serotonin and Blood Pressure Regulation

    Science.gov (United States)

    Morrison, Shaun F.; Davis, Robert Patrick; Barman, Susan M.

    2012-01-01

    5-Hydroxytryptamine (5-HT; serotonin) was discovered more than 60 years ago as a substance isolated from blood. The neural effects of 5-HT have been well investigated and understood, thanks in part to the pharmacological tools available to dissect the serotonergic system and the development of the frequently prescribed selective serotonin-reuptake inhibitors. By contrast, our understanding of the role of 5-HT in the control and modification of blood pressure pales in comparison. Here we focus on the role of 5-HT in systemic blood pressure control. This review provides an in-depth study of the function and pharmacology of 5-HT in those tissues that can modify blood pressure (blood, vasculature, heart, adrenal gland, kidney, brain), with a focus on the autonomic nervous system that includes mechanisms of action and pharmacology of 5-HT within each system. We compare the change in blood pressure produced in different species by short- and long-term administration of 5-HT or selective serotonin receptor agonists. To further our understanding of the mechanisms through which 5-HT modifies blood pressure, we also describe the blood pressure effects of commonly used drugs that modify the actions of 5-HT. The pharmacology and physiological actions of 5-HT in modifying blood pressure are important, given its involvement in circulatory shock, orthostatic hypotension, serotonin syndrome and hypertension. PMID:22407614

  8. Diabetes and blood pressure (image)

    Science.gov (United States)

    People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ... People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ...

  9. Blood Pressure Drugs and AMD

    Science.gov (United States)

    ... Patient Stories Español Eye Health / News Research News: Blood Pressure Drugs and AMD Leer en Español: Noticias de ... also found an association between AMD and high blood pressure, but this has been inconsistent. To help clarify ...

  10. High Blood Pressure - Multiple Languages

    Science.gov (United States)

    ... Being 8 - High Blood Pressure - Amarɨñña / አማርኛ (Amharic) MP3 Siloam Family Health Center Arabic (العربية) Expand Section ... Being 8 - High Blood Pressure - myanma bhasa (Burmese) MP3 Siloam Family Health Center Chinese, Simplified (Mandarin dialect) ( ...

  11. What Is High Blood Pressure?

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More What is High Blood Pressure? Updated:Feb 27,2018 First, let’s define high ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  12. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-01

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed

  13. Can an electronic device with a single cuff be accurate in a wide range of arm size? Validation of the Visomat Comfort 20/40 device for home blood pressure monitoring.

    Science.gov (United States)

    Stergiou, G S; Tzamouranis, D; Nasothimiou, E G; Protogerou, A D

    2008-11-01

    An appropriate cuff according to the individual's arm circumference is recommended with all blood pressure (BP) monitors. An electronic device for home monitoring has been developed (Visomat Comfort 20/40) that estimates the individual's arm circumference by measuring the cuff filing volume and makes an adjustment of measured BP taking into account the estimated arm circumference. Thus the manufacturer recommends the use of a single cuff for arm circumference 23-43 cm. The device accuracy was assessed using the European Society of Hypertension International Protocol. Simultaneous BP measurements were obtained in 33 adults by two observers (connected mercury sphygmomanometers) four times, sequentially with three measurements taken using the tested device. Absolute device-observer BP differences were classified into difference differences differences difference (systolic/diastolic) was 3.7 +/- 5.6/-1.5 +/- 4.7 mm Hg (4.7 +/- 4.9/ - 1.7 +/- 4.3 in arm circumference 23-29 cm [39 readings] and 3.1 +/- 5.9/-1.4 +/- 5.0 in arm 30-34 cm [60 readings], P=NS). In conclusion, the device fulfils the International Protocol requirements and can be recommended for clinical use. Interestingly, the device was accurate using a single cuff in a wide range of arm circumference (23-34 cm). This study provides no information about the device accuracy in larger arms.

  14. Validation of the A&D UM-201 device for office blood pressure measurement according to the European Society of Hypertension International Protocol Revision 2010.

    Science.gov (United States)

    Fania, Claudio; Albertini, Federica; Palatini, Paolo

    2017-08-01

    The aim of this study was to determine the accuracy of the A&D UM-201 device coupled to several cuffs for different arm sizes for office blood pressure (BP) measurement according to the International Protocol of the European Society of Hypertension. Evaluation was carried out in 33 individuals. The mean age of the individuals was 59.3±13.2 years, systolic BP was 145.4±20.6 mmHg (range: 109-186 mmHg), diastolic BP was 87.3±18.0 mmHg (range: 50-124 mmHg), and arm circumference was 30.4±4.2 cm (range: 23-39 cm). The protocol requirements were followed precisely. The UM-201 monitor passed all requirements, fulfilling the standards of the protocol. On average, the device overestimated systolic BP by 3.0±2.1 mmHg and diastolic BP by 2.6±2.0 mmHg. These data show that the A&D UM-201 device coupled to several cuffs for different ranges of arm circumference fulfilled the requirements for validation by the International Protocol and can be recommended for clinical use in the adult population.

  15. Validation of the A&D UM-211 device for office blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Fania, Claudio; Albertini, Federica; Palatini, Paolo

    2017-10-01

    The aim of this study was to define the accuracy of UM-211, an automated oscillometric device for office use coupled to several cuffs for different arm sizes, according to the International Protocol of the European Society of Hypertension. The validation was performed in 33 individuals. Their mean age was 59.6±12.9 years, systolic blood pressure (BP) was 144.3±21.5 mmHg (range: 96-184 mmHg), diastolic BP was 86.8±18.5 mmHg (range: 48-124 mmHg), and arm circumference was 30.2±4.3 cm (range: 23-39 cm). Four sequential readings were taken by observers 1 and 2 using a double-headed stethoscope and a mercury sphygmomanometer, whereas three BP readings were taken by the supervisor using the test instrument. The differences between the readings provided by the device and the mean observer measurements were calculated. Therefore, each device measurement was compared with the previous and the next mean observer measurement. The validation results fulfilled all the 2010 European Society of Hypertension revision Protocol criteria for the general population and passed all validation grades. On average, the device overestimated systolic BP by 1.7±2.4 mmHg and diastolic BP by 1.7±2.5 mmHg. These data show that the UM-211 device coupled to several cuffs for different ranges of arm circumference met the requirements for validation according to the International Protocol and can be recommended for clinical use in the adult population. However, these results mainly apply to the use of the 22-32 and the 31-45 cm cuffs.

  16. Diet, blood pressure, and multicollinearity.

    Science.gov (United States)

    Reed, D; McGee, D; Yano, K; Hankin, J

    1985-01-01

    Recent reports of an inverse association between dietary calcium intake and hypertension stimulated this analysis of the relationship of blood pressure to more than 20 dietary factors among a group of 8000 Japanese men in Hawaii. Reported intakes of potassium, calcium, protein, and milk were all inversely associated with blood pressure levels when examined one at a time while controlling for other risk factors. Alcohol intake was directly associated with blood pressure, and was treated as a confounding variable in the analysis. The association of potassium intake with blood pressure was relatively stronger than the associations for other nutrients, but the intake of potassium was so highly correlated with intakes of calcium, milk, and protein that it was not statistically possible to identify the independent association of potassium and blood pressure. Calcium intake was strongly correlated with milk and potassium intakes, and only calcium from dairy sources was associated with blood pressure. These data thus indicate that several dietary factors are inversely related to blood pressure levels independently of other risk factors such as age, body mass, and alcohol intake. The high degree of intercorrelation (multicollinearity) among these dietary factors, however, indicates that the independent role of any specific nutrient cannot be conclusively separated from the possible effects of other nutrients in this type of study.

  17. Home Monitoring of Blood Pressure: Patients' Perception and Role ...

    African Journals Online (AJOL)

    measuring devices, patients' emotional response to their blood pressure readings and actions taken in response. ... pressure, their response regarding different readings, and the .... pivotal position for providing pharmaceutical care services ...

  18. Ion suppression from blood collection devices

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo; Sejr Gothelf, Aase

    The aim of the study was to examine the variation in ion suppression in ultra high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS-MS) methods when using different blood collection devices. Three different methods measuring 18 antidepressants and antipsychotics in total were...... Terumo, S-monovette from Sarstedt, Vacuette from Greiner Bio-One and three BD Vacutainer serum tubes from BD. These seven different blood collection devices were used to withdraw blood from five healthy drug free donors (n=35) in random order. The samples were centrifuged and serum from each sample...... by UHPLC-MS-MS using three different gradients (Group I, II and III). The analytes in group I was measured on an Agilent 6460 mass spectrometer and group II and III were measured on an Agilent 6410 mass spectrometer both utilizing positive electrospray ionization. The experiments demonstrated significant...

  19. High Blood Pressure and Women

    Science.gov (United States)

    ... is known as gestational hypertension, a form of secondary hypertension caused by the pregnancy that usually disappears after delivery. If the mother is not treated, high blood pressure can be dangerous to both the mother ...

  20. Beat-to-Beat Blood Pressure Monitor

    Science.gov (United States)

    Lee, Yong Jin

    2012-01-01

    This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

  1. Validation of the Omron M6 (HEM-7001-E) upper arm blood pressure measuring device according to the International Protocol in elderly patients.

    Science.gov (United States)

    Altunkan, Sekip; Iliman, Nevzat; Altunkan, Erkan

    2008-04-01

    Despite the widespread use of automated self-measurement monitors, there is limited published evidence on their accuracy and reliability on different patient groups. The objective of this study was to evaluate the accuracy and reliability of the Omron M6 (HEM-7001-E) upper-arm blood pressure (BP) device against mercury sphygmomanometer on elderly patients according to the criteria of the International Protocol. Thirty-three patients above 65 years of age, who were classified based on the BP categories of the International Protocol, were recruited for the study. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. During the validation study, 99 measurements were obtained from 33 patients for comparison. The first phase was carried out on 15 patients and if the device passed this phase, 18 more patients were selected. Mean discrepancies and standard deviations of the device sphygmomanometer were 1.4+/-5.3 mmHg for systolic BP (SBP) and -1.4+/-4.5 mmHg for diastolic BP (DBP) in the study group. The device passed phase 1 in 15 patients. In phase 2.1, from the total 99 comparisons, 76, 92, and 97 for SBP and 77, 94, and 99 for DBP were less than 5, 10, and 15 mmHg, respectively. The Omron M6 passed phases 2.1 and 2.2 in the elderly group of patients. The Omron M6 (HEM-7001-E) upper-arm BP monitor passed according to the International Protocol criteria and can be recommended for use in elderly patients.

  2. Microfluidic Devices for Blood Fractionation

    Directory of Open Access Journals (Sweden)

    Chwee Teck Lim

    2011-07-01

    Full Text Available Blood, a complex biological fluid, comprises 45% cellular components suspended in protein rich plasma. These different hematologic components perform distinct functions in vivo and thus the ability to efficiently fractionate blood into its individual components has innumerable applications in both clinical diagnosis and biological research. Yet, processing blood is not trivial. In the past decade, a flurry of new microfluidic based technologies has emerged to address this compelling problem. Microfluidics is an attractive solution for this application leveraging its numerous advantages to process clinical blood samples. This paper reviews the various microfluidic approaches realized to successfully fractionate one or more blood components. Techniques to separate plasma from hematologic cellular components as well as isolating blood cells of interest including certain rare cells are discussed. Comparisons based on common separation metrics including efficiency (sensitivity, purity (selectivity, and throughput will be presented. Finally, we will provide insights into the challenges associated with blood-based separation systems towards realizing true point-of-care (POC devices and provide future perspectives.

  3. Psoriasis and high blood pressure.

    Science.gov (United States)

    Salihbegovic, Eldina Malkic; Hadzigrahic, Nermina; Suljagic, Edin; Kurtalic, Nermina; Sadic, Sena; Zejcirovic, Alema; Mujacic, Almina

    2015-02-01

    Psoriasis is a chronic skin ailment which can be connected with an increased occurrence of other illnesses, including high blood pressure. A prospective study has been conducted which included 70 patients affected by psoriasis, both genders, older than 18 years. Average age being 47,14 (SD= ±15,41) years, from that there were 36 men or 51,43 and 34 women or 48,57%. Average duration of psoriasis was 15,52 (SD=±12,54) years. Frequency of high blood pressure in those affected by psoriasis was 54,28%. Average age of the patients with psoriasis and high blood pressure was 53,79 year (SD=±14,15) and average duration of psoriasis was 17,19 years (SD=±13,51). Average values of PASI score were 16,65. Increase in values of PASI score and high blood pressure were statistically highly related (r=0,36, p=0,0001). Psoriasis was related to high blood pressure and there was a correlation between the severity of psoriasis and high blood pressure.

  4. Alcohol: Does It Affect Blood Pressure?

    Science.gov (United States)

    Alcohol: Does it affect blood pressure? Does drinking alcohol affect your blood pressure? Answers from Sheldon G. Sheps, M.D. Drinking too much alcohol can raise blood pressure to unhealthy levels. Having ...

  5. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  6. Anxiety: A Cause of High Blood Pressure?

    Science.gov (United States)

    ... of high blood pressure? Can anxiety cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Anxiety doesn't cause long-term high blood pressure (hypertension). But episodes of anxiety can cause dramatic, ...

  7. African Americans and High Blood Pressure

    Science.gov (United States)

    ANSWERS by heart Lifestyle + Risk Reduction High Blood Pressure What About African Americans and High Blood Pressure? African Americans in the U.S. have a higher prevalence of high blood pressure (HBP) than ...

  8. High Blood Pressure: Medicines to Help You

    Science.gov (United States)

    ... For Consumers Consumer Information by Audience For Women High Blood Pressure--Medicines to Help You Share Tweet Linkedin Pin ... Click here for the Color Version (PDF 533KB) High blood pressure is a serious illness. High blood pressure is ...

  9. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.

    Science.gov (United States)

    Altunkan, Sekip; Ilman, Nevzat; Kayatürk, Nur; Altunkan, Erkan

    2007-08-01

    Electronic blood pressure (BP) measurement devices are the preferred choice of patients owing to their user-friendly nature; however, there is a requirement to investigate the accuracy and reliability of these devices. The objective of this study is to evaluate the accuracy of the Omron M6 upper-arm BP device against the mercury sphygmomanometer in adults and obese adults according to the International Protocol criteria. One hundred and twenty-one patients, older than 30 years of age, were studied and classified on the basis of the range of the International Protocol. BP measurements at the upper arm with the Omron M6 were compared with the results obtained by two trained observers using a mercury sphygmomanometer. Nine sequential BP measurements were taken. A total of 33 participants were selected for each validation study. During the validation study, 99 measurements were performed on 33 participants for comparison. The first phase was performed on 15 participants, and if the device passed this phase, 18 more participants were selected. Having a two-fold purpose, this study was conducted on both adult and obese adult patients. Mean discrepancies and standard deviations of the monitor-mercury sphygmomanometer were 1.1+/-4.0 mmHg for systolic BP (SBP) and -0.5+/-3.5 mmHg for diastolic BP (DBP) in the adult group. The device passed phase 1 in 15 participants. In phase 2.1, out of a total of 99 comparisons, 88, 96, and 97 for SBP, and 88, 98, and 99 for DBP were M6 automatic monitor, which measures BP at the upper arm, produced results in accordance with the criteria of phases 2.1 and 2.2 in both SBP and DBP, when applied to adults and to obese adults. It was concluded that the Omron M6 device, which measures BP at the upper arm, was deemed to be in accordance with the International Protocol criteria and can be recommended for use by adults and obese adults.

  10. Diagnostic performance of an automatic blood pressure measurement device, Microlife WatchBP Home A, for atrial fibrillation screening in a real-world primary care setting.

    Science.gov (United States)

    Chan, Pak-Hei; Wong, Chun-Ka; Pun, Louise; Wong, Yu-Fai; Wong, Michelle Man-Ying; Chu, Daniel Wai-Sing; Siu, Chung-Wah

    2017-06-15

    To evaluate the diagnostic performance of a UK National Institute for Health and Care Excellence-recommended automatic oscillometric blood pressure (BP) measurement device incorporated with an atrial fibrillation (AF) detection algorithm (Microlife WatchBP Home A) for real-world AF screening in a primary healthcare setting. Primary healthcare setting in Hong Kong. This was a prospective AF screening study carried out between 1 September 2014 and 14 January 2015. The Microlife device was evaluated for AF detection and compared with a reference standard of lead-I ECG. Diagnostic performance of Microlife for AF detection. 5969 patients (mean age: 67.2±11.0 years; 53.9% female) were recruited. The mean CHA 2 DS 2 -VASc ( C : congestive heart failure [1 point]; H : hypertension [1 point]; A 2 : age 65-74 years [1 point] and age ≥75 years [2 points]; D : diabetes mellitus [1 point]; S : prior stroke or transient ischemic attack [2 points]; VA : vascular disease [1 point]; and Sc : sex category [female] [1 point])score was 2.8±1.3. AF was diagnosed in 72 patients (1.21%) and confirmed by a 12-lead ECG. The Microlife device correctly identified AF in 58 patients and produced 79 false-positives. The corresponding sensitivity and specificity for AF detection were 80.6% (95% CI 69.5 to 88.9) and 98.7% (95% CI 98.3 to 98.9), respectively. Among patients with a false-positive by the Microlife device, 30.4% had sinus rhythm, 35.4% had sinus arrhythmia and 29.1% exhibited premature atrial complexes. With the low prevalence of AF in this population, the positive and negative predictive values of Microlife device for AF detection were 42.4% (95% CI 34.0 to 51.2) and 99.8% (95% CI 99.6 to 99.9), respectively. The overall diagnostic performance of Microlife device to detect AF as determined by area under the curves was 0.90 (95% CI 0.89 to 0.90). In the primary care setting, Microlife WatchBP Home was an effective means to screen for AF, with a reasonable sensitivity of 80.6% and

  11. Trial of validation of two devices for self-measurement of blood pressure according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C.

    Science.gov (United States)

    Cotte, Uwe V; Faltenbacher, Verena H; von Willich, Werner; Bogner, Johannes R

    2008-02-01

    Two devices for self-measurement of blood pressure, one at the upper arm (Citizen CH-432B) and one at the wrist (Citizen CH-656C), were evaluated according to the International Protocol of the European Society of Hypertension. The International Protocol is divided into two phases: the first phase is performed on 15 selected participants with five participants in three different blood pressure ranges. If the devices passed this phase, 18 additional participants selected on the basis of the same criteria as in phase 1 were included. Two skilled observers performed the following blood pressure measurements: five measurements were performed with the mercury standard alternating with four measurements with each of the test devices per participant. The first measurement result from each device instrument was not included in the analysis. The difference between the blood pressure value given by the devices and that obtained by the two observers (mean of the two observers) was calculated for each pair of measurements and classified into three categories (within 5, 10 and 15 mmHg). The results were compared to the pass criteria established by the European Society of Hypertension. Afterwards the number of measurement differences falling within 5 mmHg was determined for every person. At least 22 of the 33 participants should have two of their three comparisons within 5 mmHg and there should be a maximum of three participants without a measurement difference within the 5 mmHg range. Both tested devices passed the first phase of the validation process by exceeding the required number of comparisons falling within the 5, 10 and 15 mmHg error zones. Even the second phase confirmed the validation criteria with average differences between the device and the mercury sphygmomanometer of 0.7+/-4.4 and -3.6+/-4.0 mmHg for systolic blood pressure and diastolic blood pressure, respectively, for the Citizen CH-432B device and -0.7+/-6.0 and -1.2+/-4.5 mmHg for the Citizen CH-656C device

  12. Interarm difference in blood pressure

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels

    2014-01-01

    The present study aimed at examining the interarm difference in blood pressure and its use as an indicator of peripheral arterial disease (PAD). Data were included from consecutive patients referred from their general practitioner to our vascular laboratory for possible PAD aged 50 years or older...... without known cardiac disease, renal disease, or diabetes mellitus. 824 patients (453 women) with mean age of 72 years (range: 50-101) were included. 491 patients had a diagnosis of hypertension and peripheral arterial disease (PAD) was present in 386 patients. Systolic blood pressure was 143 ± 24 mm......Hg and 142 ± 24 mmHg on the right and left arm, respectively (P = 0.015). The interarm difference was greater in patients with hypertension (P = 0.002) and PAD (P blood pressure was reproducible...

  13. TREATMENT OF INTERNAL CAROTID ARTERY OCCLUSION USING PROXIMAL CEREBRAL PROTECTION DEVICE AND ITS EFFECT ON THE BLOOD PRESSURE DYNAMICS. CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    F. В. Shukurov

    2018-01-01

    Full Text Available In 2016, according to the Ministry of Health of the Russian Federation, about 200 thousand people died from stroke. Strokes are considered as the main cause of disability of the population, causing huge economic damage to the country. One of the most common causes of ischemic stroke is atherosclerosis of the branches of the aortic arch. The most common localization of atherosclerotic plaques is the extracranial section of the carotid arteries – bifurcation and ostium of the common carotid artery and the internal carotid artery. Recanalization of occlusion of the internal carotid artery until recently was an insoluble task for interventional surgery due to the high risk of distal embolization. The invention and use of the proximal cerebral protection device, which ensure the complete cessation of blood flow, has changed the situation. Effect of carotid revascularization on arterial hypertension, due to the effect on the baroreceptors of the carotid plexus by balloon angioplasty, which leads to a reflex decrease in arterial pressure, is an additional advantage of the endovascular technique in some cases. This effect requires further study. One also needs to pay careful attention to the diagnosis and imaging of carotid artery lesions before procedure. This clinical case is the illustration that an adequate assessment of the risk factors for intraoperative complications allows to achieve maximum results of endovascular treatment.

  14. DASH diet to lower high blood pressure

    Science.gov (United States)

    ... patientinstructions/000770.htm DASH diet to lower high blood pressure To use the sharing features on this page, ... Hypertension. The DASH diet can help lower high blood pressure and cholesterol and other fats in your blood. ...

  15. High blood pressure and eye disease

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000999.htm High blood pressure and eye disease To use the sharing features on this page, please enable JavaScript. High blood pressure can damage blood vessels in the retina . The ...

  16. Vital Signs - High Blood Pressure

    Centers for Disease Control (CDC) Podcasts

    2012-10-02

    In the U.S., nearly one third of the adult population have high blood pressure, the leading risk factor for heart disease and stroke - two of the nation's leading causes of death.  Created: 10/2/2012 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/17/2012.

  17. High Blood Pressure: Unique to Older Adults

    Science.gov (United States)

    ... our e-newsletter! Aging & Health A to Z High Blood Pressure Hypertension Unique to Older Adults This section provides ... Pressure Targets are Different for Very Old Adults High blood pressure (also called hypertension) increases your chance of having ...

  18. 21 CFR 870.1110 - Blood pressure computer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood pressure computer. 870.1110 Section 870.1110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... computer. (a) Identification. A blood pressure computer is a device that accepts the electrical signal from...

  19. Pulse pressure and diurnal blood pressure variation

    DEFF Research Database (Denmark)

    Knudsen, Søren Tang; Poulsen, Per Løgstrup; Hansen, Klavs Würgler

    2002-01-01

    retinopathy, nephropathy, macrovascular disease, PP, and diurnal BP variation in a group of type 2 diabetic patients. METHODS: In 80 type 2 diabetic patients we performed 24-h ambulatory BP (AMBP) and fundus photographs. Urinary albumin excretion was evaluated by urinary albumin/creatinine ratio. Presence...... or absence of macrovascular disease was assessed by an independent physician. RESULTS: Forty-nine patients had no detectable retinal changes (grade 1), 13 had grade 2 retinopathy, and 18 had more advanced retinopathy (grades 3-6). Compared to patients without retinopathy (grade 1), patients with grades 2......BACKGROUND: In nondiabetic subjects pulse pressure (PP) is an independent predictor of cardiovascular disease and microalbuminuria. Reduced circadian blood pressure (BP) variation is a potential risk factor for the development of diabetic complications. We investigated the association between...

  20. Inter-arm blood pressure differences in pregnant women.

    Science.gov (United States)

    Poon, L C Y; Kametas, N; Strobl, I; Pachoumi, C; Nicolaides, K H

    2008-08-01

    To determine the prevalence of blood pressure inter-arm difference (IAD) in early pregnancy and to investigate its possible association with maternal characteristics. A cross-sectional observational study. Routine antenatal visit in a university hospital. A total of 5435 pregnant women at 11-14 weeks of gestation. Blood pressure was taken from both arms simultaneously with a validated automated device. The presence of inter-arm blood pressure difference of 10 mmHg or more. The IAD in systolic and diastolic blood pressure was 10 mmHg or more in 8.3 and 2.3% of the women, respectively. Systolic IAD was found to be significantly related to systolic blood pressure and pulse pressure, and diastolic IAD was found to be significantly related to maternal age, diastolic blood pressure and pulse pressure. The systolic and diastolic IAD were higher in the hypertensive group compared with the normotensive group and absolute IAD increased with increasing blood pressure. About 31.0 and 23.9% of cases of hypertension would have been underreported if the left arm and the right arm were used, respectively, in measuring the blood pressure. There is a blood pressure IAD in a significant proportion of the pregnant population, and its prevalence increases with increasing blood pressure. By measuring blood pressure only on one arm, there is a one in three chance of underreporting hypertension. Therefore, it would be prudent that during the booking visit blood pressure should be taken in both arms and thus provide guidance for subsequent blood pressure measurements during the course of pregnancy.

  1. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  2. The hidden magnitude of raised blood pressure and elevated blood ...

    African Journals Online (AJOL)

    Conclusions: The prevalence of undiagnosed raised blood pressure and elevated blood sugar was high in Ethiopia and only very small percentage of people had been aware of their high blood pressure and elevated blood sugar. Policy makers in the health sector including other health development partners need to ...

  3. Caffeine: How Does It Affect Blood Pressure?

    Science.gov (United States)

    ... naturally increase your blood pressure, such as exercise, weightlifting or hard physical labor. To see if caffeine ... blood pressure and stress indices in healthy individuals. Nutrition Journal. 2016;15:26. Cano-Marquina A, et ...

  4. What Is High Blood Pressure Medicine?

    Science.gov (United States)

    ... a medicine calendar. • Set a reminder on your smartphone. What types of medicine may be prescribed? One ... High Blood Pressure Medicine? What are their side effects? For many people, high blood pressure medicine can ...

  5. Ambulatory blood pressure monitoring - comparison with office ...

    African Journals Online (AJOL)

    ambulatory blood pressure recordings in private practice ... position according to established guidelines. ... white-coat effect was defined as a difference of at least 20 .... patients with hypertension: Importance of blood pressure response to ...

  6. High blood pressure - medicine-related

    Science.gov (United States)

    Drug-induced hypertension is high blood pressure caused by using a chemical substance or medicine. ... of the arteries There are several types of high blood pressure : Essential hypertension has no cause that can be ...

  7. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a silent threat to health. So come and get your blood pressure checked.

  8. HIGH BLOOD PRESSURE: DOES THIS CONCERN ME?

    CERN Multimedia

    2007-01-01

    To find out, the Medical Service's nurses are organising A HIGH BLOOD PRESSURE SCREENING AND PREVENTION CAMPAIGN from Monday, 26th to Thursday, 29th March 2007 at the Infirmary - Building 57 - ground floor A blood pressure test, advice, information and, if necessary, referral for specialist medical treatment will be offered to any person working on the CERN site. High blood pressure is a stealth threat to health. So come and get your blood pressure checked.

  9. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  10. Home readings of blood pressure in assessment of hypertensive subjects

    DEFF Research Database (Denmark)

    Nielsen, P.E.; Myschetzky, P; Andersen, A R

    1986-01-01

    Out-patient clinic blood pressure (OPC-BP) was compared to home blood pressure (Home-BP) measured three times daily during a two week period in 122 consecutively referred hypertensive subjects. A semi-automatic device (TM-101) including a microphone for detection of Korotkoff-sounds, self......-deflation of cuff pressure and digital display of blood pressure was used. Mean difference between OPC-BP and Home-BP was systolic +13 mm Hg (range -21 - +100 mg Hg) and diastolic +5 mm Hg (range -27 - +36 mm Hg). Although a significant correlation could be demonstrated between Home-BP and OPC-BP, the inter...

  11. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood mixing devices and blood weighing devices. 864.9195 Section 864.9195 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That...

  12. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol

    Directory of Open Access Journals (Sweden)

    Topouchian J

    2014-01-01

    Full Text Available Jirar Topouchian,1 Davide Agnoletti,1 Jacques Blacher,1 Ahmed Youssef,1 Mirna N Chahine,2,3 Isabel Ibanez,3 Nathalie Assemani,3 Roland Asmar1–31Centre de Diagnostic, Hôpital Hôtel-Dieu, Paris, France; 2Faculty of Medicine of the Lebanese University, 3Foundation-Medical Research Institutes, Beirut, LebanonBackground: Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM were evaluated according to the European Society of Hypertension (ESH International Protocol Revision 2010 in four separate studies.Methods: The four devices measure brachial blood pressure (BP using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg. The protocol procedures were followed precisely in each of the four studies.Results: All four tested devices passed the validation process. The mean differences between the device and mercury readings were: −1.8±5.1 mmHg and −0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and −1.2±4.3 mmHg for the Omron HEM-7420 device; −0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device.Conclusion: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly.Keywords: Omron M6 Comfort, Omron HEM-7420, Withings BP-800

  13. Central blood pressure and chronic kidney disease

    Science.gov (United States)

    Ohno, Yoichi; Kanno, Yoshihiko; Takenaka, Tsuneo

    2016-01-01

    In this review, we focused on the relationship between central blood pressure and chronic kidney diseases (CKD). Wave reflection is a major mechanism that determines central blood pressure in patients with CKD. Recent medical technology advances have enabled non-invasive central blood pressure measurements. Clinical trials have demonstrated that compared with brachial blood pressure, central blood pressure is a stronger risk factor for cardiovascular (CV) and renal diseases. CKD is characterized by a diminished renal autoregulatory ability, an augmented direct transmission of systemic blood pressure to glomeruli, and an increase in proteinuria. Any elevation in central blood pressure accelerates CKD progression. In the kidney, interstitial inflammation induces oxidative stress to handle proteinuria. Oxidative stress facilitates atherogenesis, increases arterial stiffness and central blood pressure, and worsens the CV prognosis in patients with CKD. A vicious cycle exists between CKD and central blood pressure. To stop this cycle, vasodilator antihypertensive drugs and statins can reduce central blood pressure and oxidative stress. Even in early-stage CKD, mineral and bone disorders (MBD) may develop. MBD promotes oxidative stress, arteriosclerosis, and elevated central blood pressure in patients with CKD. Early intervention or prevention seems necessary to maintain vascular health in patients with CKD. PMID:26788468

  14. Cuff inflations do not affect night-time blood pressure

    DEFF Research Database (Denmark)

    Petersen, Emilie H; Theilade, Simone; Hansen, Tine W

    2015-01-01

    Discomfort related to cuff inflation may bias 24 h ambulatory blood pressure (BP) measurements, especially during night-time. We accessed the impact of cuff inflations by comparing 24 h BP recorded with a cuff-less tonometric wrist device and an upper-arm oscillometric cuff device. Fifty...

  15. Microfluidic Devices for Blood Fractionation

    OpenAIRE

    Hou, Han Wei; Bhagat, Ali Asgar S.; Lee, Wong Cheng J.; Huang, Sha; Han, Jongyoon; Lim, Chwee Teck

    2011-01-01

    Blood, a complex biological fluid, comprises 45% cellular components suspended in protein rich plasma. These different hematologic components perform distinct functions in vivo and thus the ability to efficiently fractionate blood into its individual components has innumerable applications in both clinical diagnosis and biological research. Yet, processing blood is not trivial. In the past decade, a flurry of new microfluidic based technologies has emerged to address this compelling problem. ...

  16. Hybrid Optical Unobtrusive Blood Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Guangfei Zhang

    2017-07-01

    Full Text Available Blood pressure (BP is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT calculated by a pair of photoplethysmography (PPG signals at two body sites. Currently, contact PPG (cPPG and imaging PPG (iPPG are two feasible ways to obtain PPG signals. In this study, we proposed a hybrid system (called the ICPPG system employing both methods that can be implemented on a wearable device, facilitating the measurement of BP in an inconspicuous way. The feasibility of the ICPPG system was validated on a dataset with 29 subjects. It has been proved that the ICPPG system is able to estimate PTT values. Moreover, the PTT measured by the new system shows a correlation on average with BP variations for most subjects, which could facilitate a new generation of BP measurement using wearable and mobile devices.

  17. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  18. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  19. Social Stress Induced Pressure Breathing and Consequent Blood Pressure Oscillation

    NARCIS (Netherlands)

    Fokkema, Dirk S.; Koolhaas, Jaap M.; Meulen, Jan van der; Schoemaker, Regien

    1986-01-01

    A large amplitude blood pressure oscillation occurs during social defeat in a territorial fight between male rats, and during the application of a psychosocial stimulus associated with this defeat. Synchronous recording of blood pressure, intrathoracic pressure and diaphragm activity shows that the

  20. Blood Pressure Matters: Keep Hypertension in Check

    Science.gov (United States)

    ... 2016 Print this issue Blood Pressure Matters Keep Hypertension in Check En español Send us your comments ... 1 in 3 adults in the U.S. has high blood pressure, but many don’t realize it. High blood ...

  1. Pressurized waterproof case for electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-01

    having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touch-screen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein

  2. Pressurized waterproof case for electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    The pressurized waterproof case for an electronic device is particularly adapted for the waterproof containment and operation of a touch-screen computer or the like therein at some appreciable water depth. The case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touch-screen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may be a small gas cartridge (e.g., CO2), or may be provided from an external source, such as the diver\\'s breathing air. A pressure relief valve is also provided.

  3. DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE

    Science.gov (United States)

    Bradner, H.; Gordon, H.S.

    1957-12-24

    A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.

  4. Surface coating for blood-contacting devices

    Science.gov (United States)

    Nair, Ajit Kumar Balakrishnan

    The major problems always encountered with the blood-contacting surfaces are their compatibility, contact blood damage, and thrombogenicity. Titanium nitride (TiN) is a hard, inert, ceramic material that is widely used in the engineering industry. TiN has been proven to be a good biomaterial in its crystalline form, in orthopedic, and in tissue implant applications. This dissertation describes a method to coat amorphous TiN on the blood-contacting surfaces of certain medical devices using the room-temperature sputtering process and to characterize, to test, and to evaluate the coating for a reliable, durable, and compatible blood-contacting surface The blood-compatibility aspects were evaluated with standard, established protocols and procedures to prove the feasibility. An amorphous TiN coating is developed, characterized, tested, and blood compatibility evaluated by applying to the blood-contacting surfaces of stainless steel, catheters, and blood filters. The flexibility characteristics were proven by applying it to the diaphragms of the pulsatile pneumatic ventricular assist device. The results show that amorphous titanium nitride is flexible and adherent to polymeric substrates like polyurethane and polyester. Blood compatibility evaluation showed comparable results with catheters and superior behavior with stainless steel and polyester filters. It is concluded that amorphous titanium nitride can be considered to be applied to the surfaces of some of the medical devices in order to improve blood compatibility.

  5. Blood pressure documentation in the emergency department

    Science.gov (United States)

    Daniel, Ana Carolina Queiroz Godoy; Machado, Juliana Pereira; Veiga, Eugenia Velludo

    2017-01-01

    ABSTRACT Objective To analyze the frequency of blood pressure documentation performed by nursing professionals in an emergency department. Methods This is a cross-sectional, observational, descriptive, and analytical study, which included medical records of adult patients admitted to the observation ward of an emergency department, between March and May 2014. Data were obtained through a collection instrument divided into three parts: patient identification, triage data, and blood pressure documentation. For statistical analysis, Pearson’s correlation coefficient was used, with a significance level of α<0.05. Results One hundred fifty-seven records and 430 blood pressure measurements were analyzed with an average of three measurements per patient. Of these measures, 46.5% were abnormal. The mean time from admission to documentation of the first blood pressure measurement was 2.5 minutes, with 42 minutes between subsequent measures. There is no correlation between the systolic blood pressure values and the mean time interval between blood pressure documentations: 0.173 (p=0.031). Conclusion The present study found no correlation between frequency of blood pressure documentation and blood pressure values. The frequency of blood pressure documentation increased according to the severity of the patient and decreased during the length of stay in the emergency department. PMID:28444085

  6. Fall in blood pressure during radiation therapy

    International Nuclear Information System (INIS)

    Larsson, L.E.; Lindahl, J.; Unsgaard, B.

    1976-01-01

    Blood pressure and heart rate at rest in the supine and standing positions were followed before, during and after irradiation for malignant tumours in 114 patients. A statistically significant gradual reduction in blood pressure during the treatment period was established. This was more marked in older patients and in patients with higher initial blood pressure but was not related to the region irradiated or the type of tumour treated. Particularly if the patient experiences vertigo and nausea on change of position, it seems advisable to check the blood pressure during treatment. (author)

  7. Effects of hormone therapy on blood pressure.

    Science.gov (United States)

    Issa, Zeinab; Seely, Ellen W; Rahme, Maya; El-Hajj Fuleihan, Ghada

    2015-04-01

    Although hormone therapy remains the most efficacious option for the management of vasomotor symptoms of menopause, its effects on blood pressure remain unclear. This review scrutinizes evidence of the mechanisms of action of hormone therapy on signaling pathways affecting blood pressure and evidence from clinical studies. Comprehensive Ovid MEDLINE searches were conducted for the terms "hypertension" and either of the following "hormone therapy and menopause" or "selective estrogen receptor modulator" from year 2000 to November 2013. In vitro and physiologic studies did not reveal a clear deleterious effect of hormone therapy on blood pressure. The effect of oral therapy was essentially neutral in large trials conducted in normotensive women with blood pressure as primary outcome. Results from all other trials had several limitations. Oral therapy had a neutral effect on blood pressure in hypertensive women. Transdermal estrogen and micronized progesterone had a beneficial effect on blood pressure in normotensive women and, at most, a neutral effect on hypertensive women. In general, tibolone and raloxifene had a neutral effect on blood pressure in both hypertensive and normotensive women. Large randomized trials are needed to assess the effect of oral hormone therapy on blood pressure as a primary outcome in hypertensive women and the effect of transdermal preparations on both normotensive and hypertensive women. Transdermal preparations would be the preferred mode of therapy for hypertensive women, in view of their favorable physiologic and clinical profiles. The decision regarding the use of hormone therapy should be individualized, and blood pressure should be monitored during the course of treatment.

  8. Weightlifting: Bad for Your Blood Pressure?

    Science.gov (United States)

    ... individuals. American Journal of Physiology. Heart and Circulatory Physiology. 2016;311:H1024. Carlson DJ, et al. Isometric exercise training for blood pressure management: A systematic review ...

  9. Pressure-Application Device for Testing Pressure Sensors

    Science.gov (United States)

    2002-01-01

    A portable pressure-application device has been designed and built for use in testing and calibrating piezoelectric pressure transducers in the field. The device generates pressure pulses of known amplitude. A pressure pulse (in contradistinction to a steady pressure) is needed because in the presence of a steady pressure, the electrical output of a piezoelectric pressure transducer decays rapidly with time. The device includes a stainless- steel compressed-air-storage cylinder of 500 cu cm volume. A manual hand pump with check valves and a pressure gauge are located at one end of the cylinder. A three-way solenoid valve that controls the release of pressurized air is located at the other end of the cylinder. Power for the device is provided by a 3.7-V cordless-telephone battery. The valve is controlled by means of a pushbutton switch, which activates a 5 V to +/-15 V DC-to-DC converter that powers the solenoid. The outlet of the solenoid valve is connected to the pressure transducer to be tested. Before the solenoid is energized, the transducer to be tested is at atmospheric pressure. When the solenoid is actuated by the push button, pressurized air from inside the cylinder is applied to the transducer. Once the pushbutton is released, the cylinder pressure is removed from the transducer and the pressurized air applied to the transducer is vented, bringing the transducer back to atmospheric pressure. Before this device was used for actual calibration, its accuracy was checked with a NIST (National Institute of Standards and Technology) traceable calibrator and commercially calibrated pressure transducers. This work was done by Wanda Solano of Stennis Space Center and Greg Richardson of Lockheed Martin Corp.

  10. Validation of four devices: Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 for home blood pressure measurement according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Topouchian, Jirar; Agnoletti, Davide; Blacher, Jacques; Youssef, Ahmed; Chahine, Mirna N; Ibanez, Isabel; Assemani, Nathalie; Asmar, Roland

    2014-01-01

    Four oscillometric devices, including the Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670, designed for self-blood pressure measurement (SBPM) were evaluated according to the European Society of Hypertension (ESH) International Protocol Revision 2010 in four separate studies. The four devices measure brachial blood pressure (BP) using the oscillometric method. The Withings BP-800 has to be connected to an Apple® iOS device such as an iPhone®, iPad®, or iPod®. The ESH International Protocol Revision 2010 includes a total number of 33 subjects. The difference between observer and device BP values was calculated for each measure. Ninety-nine pairs of BP differences were classified into three categories (≤5 mmHg, ≤10 mmHg, ≤15 mmHg). The protocol procedures were followed precisely in each of the four studies. All four tested devices passed the validation process. The mean differences between the device and mercury readings were: -1.8±5.1 mmHg and -0.4±2.8 mmHg for systolic and diastolic BP, respectively, using the Omron M6 Comfort device; 2.5±4.6 mmHg and -1.2±4.3 mmHg for the Omron HEM-7420 device; -0.2±5.0 mmHg and 0.4±4.2 mmHg for the Withings BP-800 device; and 3.0±5.3 mmHg and 0.3±5.2 mmHg for the Polygreen KP-7670 device. Omron M6 Comfort, Omron HEM-7420, Withings BP-800, and Polygreen KP-7670 readings differing by less than 5 mmHg, 10 mmHg, and 15 mmHg fulfill the ESH International Protocol Revision 2010 requirements, and therefore are suitable for use by patients for SBPM, if used correctly.

  11. Nutraceuticals for blood pressure control.

    Science.gov (United States)

    Sirtori, Cesare R; Arnoldi, Anna; Cicero, Arrigo F G

    2015-01-01

    Significant effects on blood pressure (BP) have been reported from large nutritional interventions, particularly the Dietary Approaches to Stop Hypertension (DASH) and the Mediterranean diet. In more recent years, numerous studies have investigated the possible BP-lowering effect of different nutraceuticals; these range from specific foods to minerals, lipids, whole proteins, peptides, amino acids, probiotics, and vitamins. While a very large body of evidence supports the use of potassium, L-arginine, vitamins C and D, cocoa flavonoids, beetroot juice, some probiotics, coenzyme Q10, controlled-release melatonin, aged garlic extract, and coffee, the use of other nutraceuticals, such as green tea, flaxseed, and resveratrol, has not as yet been supported by adequate evidence. In some cases, e.g. proteins/peptides, the responsible component needs also to be fully uncovered. Finally, while for most of the products only short-term studies are available, with no specific end-points, an ongoing very large prospective study on chocolate flavanols will answer the question whether this may reduce cardiovascular risk. Thus, in addition to data on long-term safety, further clinical research is advisable in order to identify, among active nutraceuticals, those with the best cost-effectiveness and risk-benefit ratio for a wide use in the general population with a raised cardiovascular risk consequent to uncomplicated hypertension.

  12. Ambulatory blood pressure profiles in familial dysautonomia.

    Science.gov (United States)

    Goldberg, Lior; Bar-Aluma, Bat-El; Krauthammer, Alex; Efrati, Ori; Sharabi, Yehonatan

    2018-02-12

    Familial dysautonomia (FD) is a rare genetic disease that involves extreme blood pressure fluctuations secondary to afferent baroreflex failure. The diurnal blood pressure profile, including the average, variability, and day-night difference, may have implications for long-term end organ damage. The purpose of this study was to describe the circadian pattern of blood pressure in the FD population and relationships with renal and pulmonary function, use of medications, and overall disability. We analyzed 24-h ambulatory blood pressure monitoring recordings in 22 patients with FD. Information about medications, disease severity, renal function (estimated glomerular filtration, eGFR), pulmonary function (forced expiratory volume in 1 s, FEV1) and an index of blood pressure variability (standard deviation of systolic pressure) were analyzed. The mean (± SEM) 24-h blood pressure was 115 ± 5.6/72 ± 2.0 mmHg. The diurnal blood pressure variability was high (daytime systolic pressure standard deviation 22.4 ± 1.5 mmHg, nighttime 17.2 ± 1.6), with a high frequency of a non-dipping pattern (16 patients, 73%). eGFR, use of medications, FEV1, and disability scores were unrelated to the degree of blood pressure variability or to dipping status. This FD cohort had normal average 24-h blood pressure, fluctuating blood pressure, and a high frequency of non-dippers. Although there was evidence of renal dysfunction based on eGFR and proteinuria, the ABPM profile was unrelated to the measures of end organ dysfunction or to reported disability.

  13. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  14. Side effects of ambulatory blood pressure monitoring.

    NARCIS (Netherlands)

    Steen, M.S. van der; Lenders, J.W.M.; Thien, Th.

    2005-01-01

    OBJECTIVE: To study the experiences and complaints of patients who underwent 24 h blood pressure monitoring. METHODS: Two groups of hypertensive patients of a tertiary outpatient clinic were asked to fill in a nine-item questionnaire about the side effects of ambulatory blood pressure monitoring

  15. Managing Stress to Control High Blood Pressure

    Science.gov (United States)

    ... Aortic Aneurysm More Managing Stress to Control High Blood Pressure Updated:Jan 29,2018 The importance of stress ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  16. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  17. Sodium-blood pressure interrelationship in pregnancy.

    Science.gov (United States)

    Franx, A; Steegers, E A; de Boo, T; Thien, T; Merkus, J M

    1999-03-01

    In non-pregnant individuals, a strong positive association of sodium intake with blood pressure has been established, but the relationship between sodium intake and blood pressure in human pregnancy remains obscure up to date. The aim of this prospective observational cohort study was to assess the relationship between urinary sodium excretion (as a measure for intake) and blood pressure from the early second trimester onwards throughout pregnancy. The study group consisted of 667 low-risk women with singleton pregnancies, of whom 350 were nulliparous and 317 parous. Blood pressure was measured in a standardised fashion at predetermined intervals from the first antenatal visit prior to 16 weeks gestation until delivery. Urinary sodium excretion was measured in 24-h urine collections on at least four occasions between 16 and 38 weeks gestation. Main outcome measures were the coefficients of correlation between changes in urinary sodium output and changes in blood pressure during six different gestational epochs. No significant correlations were found between changes in urinary sodium output and changes in blood pressure. Correlation coefficients were alike for nulliparous and parous women and for different gestational intervals. Prior to 32 weeks gestation, no differences were observed in sodium excretion between women who remained normotensive and those who developed gestational hypertension. These results suggest that changes in sodium intake are not associated with blood pressure changes in low-risk pregnant women. Blood pressure increases as observed in the second half of normotensive and hypertensive pregnancies are unlikely to be caused by changes in renal sodium handling.

  18. Dietary protein and blood pressure : epidemiological studies

    NARCIS (Netherlands)

    Altorf-van der Kuil, W.

    2012-01-01


    Background
    Elevated blood pressure is a major risk factor for cardiovascular diseases. Diet and lifestyle have a substantial impact on blood pressure, but the role of protein intake is not yet clear. This thesis focuses on total dietary protein, types of protein (i.e. plant and

  19. Blood pressure in ICSI-conceived adolescents

    NARCIS (Netherlands)

    Belva, F.; Roelants, M.; de Schepper, J.; Roseboom, T. J.; Bonduelle, M.; Devroey, P.; Painter, R. C.

    2012-01-01

    Do young adolescents conceived by ICSI display a higher blood pressure than spontaneously conceived (SC) adolescents? In our study, 14-year-old male and female ICSI teenagers were not found to have increased blood pressure at rest. Only limited data are available regarding the cardiovascular risk of

  20. Blood pressure regulation in diabetic autonomic neuropathy

    DEFF Research Database (Denmark)

    Hilsted, J

    1985-01-01

    Defective blood pressure responses to standing, exercise and epinephrine infusions have been demonstrated in diabetic patients with autonomic neuropathy. The circulatory mechanisms underlying blood pressure responses to exercise and standing up in these patients are well characterized: In both...... which may contribute to exercise hypotension in these patients. During hypoglycemia, blood pressure regulation seems intact in patients with autonomic neuropathy. This is probably due to release of substantial amounts of catecholamines during these experiments. During epinephrine infusions a substantial...... blood pressure fall ensues in patients with autonomic neuropathy, probably due to excessive muscular vasodilation. It is unresolved why blood pressure regulation is intact during hypoglycemia and severely impaired--at similar catecholamine concentrations--during epinephrine infusions....

  1. Simultaneous validation of the SunTech CT40 automated blood pressure measurement device by the 1993 British Hypertension Society protocol and the Association for the Advancement of Medical Instrumentation/International Organization for Standardization 81060-2: 2013 standard.

    Science.gov (United States)

    Polo Friz, Hernan; Punzi, Veronica; Petri, Francesco; Orlandi, Riccardo; Maggiolini, Daniele; Polo Friz, Melisa; Primitz, Laura; Vighi, Giuseppe

    2017-10-01

    This study aimed to perform a simultaneous, third-party, independent validation of the oscillometric SunTech CT40 device for blood pressure (BP) measurement, according to the 1993 protocol of the British Hypertension Society and the standard of the Association for the Advancement of Medical Instrumentation (AAMI)/the International Organization for Standardization (ISO) 81060-2:2013. Patient recruitment, study procedures, and data analysis followed the recommendations stated by the protocols. The study was approved by the institutional review board. A total of 94 participants were included, 52 (55.3%) women, mean±SD age: 63.1±18.0 years, mean±SD arm circumference: 35.0±9.0 cm. The average of observers' entry BPs was 146.9±37.2 mmHg for systolic blood pressure (SBP) and 82.2±22.1 mmHg for diastolic blood pressure (DBP). Differences between the standard measurement and the test device within 5, 10, and 15 mmHg, for the better observer, were 79.4, 96.5, and 100.0% for SBP and 82.6, 97.5, and 100.0% for DBP, respectively. The mean±SD differences between the readings obtained using the test device and those obtained by the observers (AAMI/ISO 81060-2:2013 standard criterion 1) were 0.3±5.0 mmHg (SBP) and -0.8±4.3 mmHg (DBP), and the mean±SD differences between average of reference readings and average of test device readings in each patient (criterion 2) were 0.3±3.9 and -0.8±3.5 mmHg for SBP and DBP, respectively. The CT40 BP device achieved A/A grade of the British Hypertension Society protocol and fulfilled the requirements (criteria 1 and 2) of the AAMI/ISO standard. CT40 can be recommended for BP measurement in adults.

  2. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2016-08-01

    This study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor SCIAN LD-735 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were measured sequentially in 33 adult Chinese participants (10 women, mean age 44.8 years) using a mercury sphygmomanometer (two observers) and the SCIAN LD-735 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The SCIAN LD-735 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 86/99, 97/99, and 98/99, respectively, for systolic blood pressure and 85/99, 98/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. In total, 30 and 33 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The SCIAN wrist blood pressure monitor LD-735 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  3. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  4. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  5. Title: variations and sensitivities of some blood pressure monitors ...

    African Journals Online (AJOL)

    Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Accuracy in blood pressure meters is of essence to health, especially in blood pressure monitoring and treatment. The aim of this research was to compare the readings and the sensitivities of some blood pressure monitors in use ...

  6. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  7. Questionable accuracy of home blood pressure measurements in the obese population - Validation of the Microlife WatchBP O3® and Omron RS6® devices according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Azaki, Alaa; Diab, Reem; Harb, Aya; Asmar, Roland; Chahine, Mirna N

    2017-01-01

    Two oscillometric devices, the Microlife WatchBP O3 ® and the Omron RS6 ® , designed for self-blood pressure measurement were evaluated according to the European Society of Hypertension (ESH)-International Protocol (IP) Revision 2010 in the obese population. The Microlife WatchBP O3 measures blood pressure (BP) at the brachial level and the Omron RS6 measures BP at the wrist level. The ESH-IP revision 2010 includes a total of 33 subjects. The difference between observers' and device BP values was calculated for each measure. A total of 99 pairs of BP differences were classified into three categories (≤5, ≤10, and ≤15 mmHg). The protocol procedures were followed precisely in each of the two studies. Microlife WatchBP O3 and Omron RS6 failed to fulfill the criteria of the ESH-IP. The mean differences between the device and the mercury readings were: 0.3±7.8 mmHg and -1.9±6.4 mmHg for systolic BP and diastolic BP, respectively, for Microlife WatchBP O3, and 2.7±9.9 mmHg for SBP and 3.5±11.1 mmHg for diastolic BP for Omron RS6. Microlife WatchBP O3 and Omron RS6 readings differing from the mercury standard by more than 5, 10, and 15 mmHg failed to fulfill the ESH-IP revision 2010 requirements in obese subjects. Therefore, the two devices cannot be recommended for use in obese subjects.

  8. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  9. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  10. Elevated preoperative blood pressures in adult surgical patients are highly predictive of elevated home blood pressures.

    Science.gov (United States)

    Schonberger, Robert B; Nwozuzu, Adambeke; Zafar, Jill; Chen, Eric; Kigwana, Simon; Monteiro, Miriam M; Charchaflieh, Jean; Sophanphattana, Sophisa; Dai, Feng; Burg, Matthew M

    2018-04-01

    Blood pressure (BP) measurement during the presurgical assessment has been suggested as a way to improve longitudinal detection and treatment of hypertension. The relationship between BP measured during this assessment and home blood pressure (HBP), a better indicator of hypertension, is unknown. The purpose of the present study was to determine the positive predictive value of presurgical BP for predicting elevated HBP. We prospectively enrolled 200 patients at a presurgical evaluation clinic with clinic blood pressures (CBPs) ≥130/85 mm Hg, as measured using a previously validated automated upper-arm device (Welch Allyn Vital Sign Monitor 6000 Series), to undergo daily HBP monitoring (Omron Model BP742N) between the index clinic visit and their day of surgery. Elevated HBP was defined, per American Heart Association guidelines, as mean systolic HBP ≥135 mm Hg or mean diastolic HBP ≥85 mm Hg. Of the 200 participants, 188 (94%) returned their home blood pressure monitors with valid data. The median number of HBP recordings was 10 (interquartile range, 7-14). Presurgical CBP thresholds of 140/90, 150/95, and 160/100 mm Hg yielded positive predictive values (95% confidence interval) for elevated HBP of 84.1% (0.78-0.89), 87.5% (0.81-0.92), and 94.6% (0.87-0.99), respectively. In contrast, self-reported BP control, antihypertensive treatment, availability of primary care, and preoperative pain scores demonstrated poor agreement with elevated HBP. Elevated preoperative CBP is highly predictive of longitudinally elevated HBP. BP measurement during presurgical assessment may provide a way to improve longitudinal detection and treatment of hypertension. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.

  11. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events

    DEFF Research Database (Denmark)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke

    2017-01-01

    Aims: To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Methods...... and results: A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events....... Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0...

  12. Device for determining pressures in aggressive atmospheres

    International Nuclear Information System (INIS)

    Schley, Robert; Voituriez, Bernard.

    1982-01-01

    This invention concerns a compact device for measuring rapidly changing pressures at high temperature and in corrosive or radioactive atmospheres. The device includes a case in which there is a support having two plane surfaces, an elliptical flexible membrane fixed to the first plane surface and supporting a strain gauge, a second gauge fixed to the second plane surface, the support being fitted with a passage enabling the membrane to distort under the action of the fluid it is desired to measure for pressure. Applies to the determination of pressures in nuclear reactors [fr

  13. Segmental blood pressure after total hip replacement

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Soelberg, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Twenty-nine patients due to have a total hip replacement had their systemic systolic and segmental blood pressures measured prior to operation and 1 and 6 weeks postoperatively. No patients had signs of ischemia. The segmental blood pressure was measured at the ankle and at the toes. A significant...... drop was found in all pressures 1 week postoperatively. The decrease followed the systemic pressure and was restored to normal after 6 weeks. In a group of six patients with preoperatively decreased ankle pressure, a significant transient further decrease in the ankle-toe gradient pressure was found...... on the operated side. None of the patients had symptoms from the lowered pressure. We conclude that in patients without signs of ischemia, the postoperative segmental pressure decrease is reversible and therefore not dangerous....

  14. Is the area under blood pressure curve the best parameter to evaluate 24-h ambulatory blood pressure monitoring data?

    Science.gov (United States)

    Nobre, Fernando; Mion, Décio

    2005-10-01

    Ambulatory blood pressure monitoring (ABPM) provides relevant data about blood pressure over a 24-h period. The analysis of parameters to determine the blood pressure profile from these data is of great importance. To calculate areas under systolic and diastolic blood pressure curves (SBP-AUC/DBP-AUC) and compare with systolic and diastolic blood pressure load (SBPL/DBPL) and 24-h systolic and diastolic blood pressure (24-h SBP/24-h DBP) in order to determine which provides the best correlation with left ventricular mass index (LVMI). ABPM measurements (1143 individuals) were analyzed to obtain 24-h SBP/24-h DBP, SBPL/DBPL, and SBP-AUC/ DBP-AUC, using Spacelabs (90207) and CardioSistemas devices. Left ventricular mass was determined using an echocardiograph HP Sonos 5500 and LVMI was calculated. The correlations between all possible pairs within the group 24-h SBP/SBPL/SBP-AUC and 24-h DBP/DBPL/DBP-AUC were high and statistically significant. The correlations between 24-h SBP/24-h DBP and SBP-AUC/DBP-AUC with SBPL/DBPL close to 100%, were lower than those mentioned above. The correlations of the parameters obtained by ABPM with LVMI were also high and statistically significant, except for blood pressure load between 90 and 100%, and for 24-h SBP of 135 mmHg or less and SBPL higher than 50%. SBPL/DBPL and SBP-AUC/DBP-AUC can be used for the evaluation of ABPM data owing to the strong correlation with 24-h SBP/24-h DBP and with LVMI, except when SBPL is close to 100% or 24-h SBP is below 135 mmHg but SBPL is above 50%. SBP-AUC/DBP-AUC, however, are a better alternative because they do not have the limitations of blood pressure load or even of 24-h blood pressure present.

  15. Pressure releasing device for reactor container

    International Nuclear Information System (INIS)

    Takeda, Mika.

    1994-01-01

    In the present invention, dose rate to public caused by radioactive rare gases can be decreased. That is, a reactor container contains a reactor pressure vessel incorporating a reactor core. There are disposed a pressure releasing system for releasing the pressure in the reactor pressure vessel to the outside, and a burning device for burning gases released from the pressure releasing system. An exhaustion pipe is disposed to the pressure releasing system. A burning device is disposed to the exhaustion pipe. It is effective to dispose a ventilation port at a portion of the exhaustion pipe upstream of the burning device. In addition, the burning device may preferably be disposed in a multi-stage in the axial direction of the exhaustion pipe. With such procedures, hydrogen in gases discharged along with the release of the pressure in the container is burned. Buoyancy is caused to the exhaustion gases by heat energy upon burning. Since the exhaustion gases can reach a higher level by the buoyancy, the dose rate due to the rare gases can be reduced. (I.S.)

  16. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  17. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  18. Improving Blood Pressure Control Using Smart Technology.

    Science.gov (United States)

    Ciemins, Elizabeth L; Arora, Anupama; Coombs, Nicholas C; Holloway, Barbara; Mullette, Elizabeth J; Garland, Robin; Walsh Bishop-Green, Shannon; Penso, Jerry; Coon, Patricia J

    2018-03-01

    The authors sought to determine if wireless oscillometric home blood pressure monitoring (HBPM) that integrates with smartphone technology improves blood pressure (BP) control among patients with new or existing uncontrolled hypertension (HTN). A prospective observational cohort study monitored BP control before and after an educational intervention and introduction to HBPM. Patients in the intervention group were instructed to track their BP using a smartphone device three to seven times per week. Cases were matched to controls at a 1:3 allocation ratio on several clinical characteristics over the same period and received usual care. The proportion of patients with controlled BP was compared between groups at pre- and postintervention, ∼9 months later. Results and Materials: The total study population included 484 patients with mean age 60 years (range 23-102 years), 47.7% female, and 84.6% Caucasian. Mean preintervention BP was 137.8 mm Hg systolic and 81.4 mm Hg diastolic. Mean BP control rates improved for patients who received HBPM from 42% to 67% compared with matched control patients who improved from 59% to 67% (p technology has the potential to improve HTN management among patients with uncontrolled or newly diagnosed HTN. Technology needs to be easy to use and operate and would work best when integrated into local electronic health record systems. In systems without this capability, medical assistants or other personnel may be trained to facilitate the process. Nurse navigator involvement was instrumental in bridging communication between the patients and provider.

  19. Clinical study on influences of enteric coated aspirin on blood pressure and blood pressure variability.

    Science.gov (United States)

    Ji, A-L; Chen, W-W; Huang, W-J

    2016-12-01

    We investigated the effects of oral administration of enteric coated aspirin (ASA) on blood pressure and blood pressure variability of hypertension patients before sleep. We observed 150 hypertension cases, classified as Grade 1-2, from September 2006 to March 2008. They are divided into a control group with 30 cases, ASA I group with 60 cases and ASA II group with 60 cases randomly. Subjects in the control group had proper diets, were losing weight, exercising and maintaining a healthy mentality and were taking 30 mg Adalat orally once a day. Based on the treatment of control group, patients in ASA I group were administered 0.1 g Bayaspirin (produced by Bayer Company) at drought in the morning. Also, based on the treatment of control group, patients in ASA II group were administered 0.1 g Bayaspirin at draught before sleep. The course of treatment is 3 months and then after the treatment, decreasing blood pressure and blood pressure variability conditions in three groups will be compared. Through the comparison of ASA II group with the control group, they have differences in terms of systolic blood pressure (SBP), diastolic blood pressure (DBP), decreasing range of blood pressure and blood pressure variability (p sleep has synergistic effects on decreasing blood pressure of hypertension patients and improving blood pressure variability.

  20. Reducing maternal mortality: Systolic blood pressure

    African Journals Online (AJOL)

    2006-03-21

    Mar 21, 2006 ... While deaths due to fluid overload have ... of better fluid balance management, we have made .... systolic blood pressure plays a significant role in the .... one looks at the work of Martin et al.5 ... Promoting Healthy Life.

  1. Dietary fiber and blood pressure control.

    Science.gov (United States)

    Aleixandre, A; Miguel, M

    2016-04-01

    In the past few years, new strategies to control blood pressure levels are emerging by developing new bioactive components of foods. Fiber has been linked to the prevention of a number of cardiovascular diseases and disorders. β-Glucan, the main soluble fiber component in oat grains, was initially linked to a reduction in plasma cholesterol. Several studies have shown afterward that dietary fiber may also improve glycaemia, insulin resistance and weight loss. The effect of dietary fiber on arterial blood pressure has been the subject of far fewer studies than its effect on the above-mentioned variables, but research has already shown that fiber intake can decrease arterial blood pressure in hypertensive rats. Moreover, certain fibers can improve arterial blood pressure when administered to hypertensive and pre-hypertensive subjects. The present review summarizes all those studies which attempt to establish the antihypertensive effects of dietary fiber, as well as its effect on other cardiovascular risk factors.

  2. Preeclampsia and High Blood Pressure During Pregnancy

    Science.gov (United States)

    ... Gynecologists f AQ FREQUENTLY ASKED QUESTIONS FAQ034 PREGNANCY Preeclampsia and High Blood Pressure During Pregnancy • What is ... is chronic hypertension during pregnancy managed? • What is preeclampsia? • When does preeclampsia occur? • What causes preeclampsia? • What ...

  3. Teaming Up Against High Blood Pressure

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the September 2012 CDC Vital Signs report. A team-based approach by patients, health care systems, and health care providers is one of the best ways to treat uncontrolled high blood pressure.

  4. Impact of calibration on estimates of central blood pressures.

    Science.gov (United States)

    Soender, T K; Van Bortel, L M; Møller, J E; Lambrechtsen, J; Hangaard, J; Egstrup, K

    2012-12-01

    Using the Sphygmocor device it is recommended that the radial pressure wave is calibrated for brachial systolic blood pressure (SBP) and diastolic blood pressure (DBP). However it has been suggested that brachial-to-radial pressure amplification causes underestimation of central blood pressures (BPs) using this calibration. In the present study we examined if different calibrations had an impact on estimates of central BPs and on the clinical interpretation of our results. On the basis of ambulatory BP measurements, patients were categorized into patients with controlled, uncontrolled or resistant hypertension. We first calibrated the radial pressure wave as recommended and afterwards recalibrated the same pressure wave using brachial DBP and calculated mean arterial pressure. Recalibration of the pressure wave generated significantly higher estimates of central SBP (P=0.0003 and Plost in patients with resistant hypertension (P=0.15). We conclude that calibration with DBP and mean arterial pressure produces higher estimates of central BPs than recommended calibration. The present study also shows that this difference between the two calibration methods can produce more than a systematic error and has an impact on interpretation of clinical results.

  5. Influence of short-term blood pressure variability on blood pressure determinations

    NARCIS (Netherlands)

    Bos, W. J.; van Goudoever, J.; van Montfrans, G. A.; Wesseling, K. H.

    1992-01-01

    To evaluate the effect of blood pressure variability on Riva Rocci Korotkoff blood pressure determinations, we studied the intra-arterial pressure during Riva Rocci Korotkoff determinations in 25 patients. In 50 measurements with a cuff deflation rate of 2.5 mm Hg/sec, the systolic intra-arterial

  6. Cocoa, blood pressure, and cardiovascular health.

    Science.gov (United States)

    Ferri, Claudio; Desideri, Giovambattista; Ferri, Livia; Proietti, Ilenia; Di Agostino, Stefania; Martella, Letizia; Mai, Francesca; Di Giosia, Paolo; Grassi, Davide

    2015-11-18

    High blood pressure is an important risk factor for cardiovascular disease and cardiovascular events worldwide. Clinical and epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. According to this, cocoa has a high content in polyphenols, especially flavanols. Flavanols have been described to exert favorable effects on endothelium-derived vasodilation via the stimulation of nitric oxide-synthase, the increased availability of l-arginine, and the decreased degradation of NO. Cocoa may also have a beneficial effect by protecting against oxidative stress alterations and via decreased platelet aggregation, decreased lipid oxidation, and insulin resistance. These effects are associated with a decrease of blood pressure and a favorable trend toward a reduction in cardiovascular events and strokes. Previous meta-analyses have shown that cocoa-rich foods may reduce blood pressure. Long-term trials investigating the effect of cocoa products are needed to determine whether or not blood pressure is reduced on a chronic basis by daily ingestion of cocoa. Furthermore, long-term trials investigating the effect of cocoa on clinical outcomes are also needed to assess whether cocoa has an effect on cardiovascular events. A 3 mmHg systolic blood pressure reduction has been estimated to decrease the risk of cardiovascular and all-cause mortality. This paper summarizes new findings concerning cocoa effects on blood pressure and cardiovascular health, focusing on putative mechanisms of action and "nutraceutical " viewpoints.

  7. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Huang, Jinhua; Li, Zhijie; Li, Guimei; Liu, Zhaoying

    2015-10-01

    This study aimed to evaluate the accuracy of the Andon KD-5965 upper-arm blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adults, with 20 women using a mercury sphygmomanometer (two observers) and the Andon KD-5965 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 70/99, 91/99, and 98/99, respectively, for systolic blood pressure and 81/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Twenty-five and 29 participants, for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required≥24). Two and one participants for systolic and diastolic blood pressure, respectively, had all three device-observers comparisons greater than 5 mmHg. According to the validation results, with better performance for diastolic blood pressure than that for systolic blood pressure, the Andon automated oscillometric upper-arm blood pressure monitor KD-5965 fulfilled the requirements of the European Society of Hypertension International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  8. Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Zhang, Lu; Kang, Yuan-Yuan; Zeng, Wei-Fang; Li, Yan; Wang, Ji-Guang

    2015-04-01

    The present study aimed to evaluate the accuracy of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (17 women, mean age 46 years) using a mercury sphygmomanometer (two observers) and the Rossmax CF175 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The Rossmax CF175 device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg was 78/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 81/99, 96/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-nine participants, for both of systolic and diastolic blood pressure, had at least two of the three device-observers differences within 5 mmHg (required ≥24). Only one participant for diastolic blood pressure had all three device-observers comparisons greater than 5 mmHg. The Rossmax automated oscillometric upper-arm blood pressure monitor CF175 fulfilled the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement in adults.

  9. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  10. Blood Pressure Quiz | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... this page please turn Javascript on. Feature: High Blood Pressure Blood Pressure Quiz Past Issues / Fall 2011 Table of Contents Blood pressure changes throughout the day. It… is highest while ...

  11. Calcium Supplements: Do They Interfere with Blood Pressure Drugs?

    Science.gov (United States)

    ... with blood pressure drugs? Is it true that calcium supplements may interact with blood pressure medications? Answers ... G. Sheps, M.D. Yes. In large amounts, calcium supplements may interact with some blood pressure medications. ...

  12. A Universal Standard for the Validation of Blood Pressure Measuring Devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Collaboration Statement.

    Science.gov (United States)

    Stergiou, George S; Alpert, Bruce; Mieke, Stephan; Asmar, Roland; Atkins, Neil; Eckert, Siegfried; Frick, Gerhard; Friedman, Bruce; Graßl, Thomas; Ichikawa, Tsutomu; Ioannidis, John P; Lacy, Peter; McManus, Richard; Murray, Alan; Myers, Martin; Palatini, Paolo; Parati, Gianfranco; Quinn, David; Sarkis, Josh; Shennan, Andrew; Usuda, Takashi; Wang, Jiguang; Wu, Colin O; O'Brien, Eoin

    2018-03-01

    In the past 30 years, several organizations, such as the US Association for the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society, the European Society of Hypertension (ESH) Working Group on Blood Pressure (BP) Monitoring, and the International Organization for Standardization (ISO), have developed protocols for clinical validation of BP measuring devices. However, it is recognized that science, as well as patients, consumers, and manufacturers, would be best served if all BP measuring devices were assessed for accuracy according to an agreed single validation protocol that had global acceptance. Therefore, an international initiative was taken by the AAMI, ESH, and ISO experts who agreed to develop a universal standard for device validation. This statement presents the key aspects of a validation procedure, which were agreed by the AAMI, ESH, and ISO representatives as the basis for a single universal validation protocol. As soon as the AAMI/ESH/ISO standard is fully developed, this will be regarded as the single universal standard and will replace all other previous standards/protocols. © 2018 American Heart Association, Inc., and Wolters Kluwer Health, Inc.

  13. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  14. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  15. Validation of the HONSUN LD-578 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.

    Science.gov (United States)

    Zhang, Yi; Wang, Jie; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2009-06-01

    This study aimed to evaluate the accuracy of the automated oscillometric upper arm blood pressure monitor LD-578 (HONSUN Group, Shanghai, China) for home blood pressure monitoring according to the International Protocol. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese using a mercury sphygmomanometer (two observers) and the LD-578 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was performed using the ESHIP Analyzer. The LD-578 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 32 of 45, 41 of 45, and 45 of 45 measurements (required 25, 35, and 40), respectively. The device also achieved the targets for phase 2.1, with 67 of 99, 90 of 99, and 98 of 99 differences within 5, 10, and 15 mmHg, respectively, for systolic blood pressure, and with 69 of 99, 95 of 99, and 98 of 99 within 5, 10, and 15 mmHg, respectively, for diastolic blood pressure. In phase 2.2, 24 participants had at least two of the three device-observers differences within 5 mmHg (required >or=22) for systolic and diastolic blood pressure. The HONSUN upper arm blood pressure monitor LD-578 can be recommended for home use in adults.

  16. Effect of cocoa on blood pressure.

    Science.gov (United States)

    Ried, Karin; Fakler, Peter; Stocks, Nigel P

    2017-04-25

    High blood pressure is an important risk factor for cardiovascular disease, contributing to about 50% of cardiovascular events worldwide and 37% of cardiovascular-related deaths in Western populations. Epidemiological studies suggest that cocoa-rich products reduce the risk of cardiovascular disease. Flavanols found in cocoa have been shown to increase the formation of endothelial nitric oxide which promotes vasodilation and therefore blood pressure reduction. Here we update previous meta-analyses on the effect of cocoa on blood pressure. To assess the effects on blood pressure of chocolate or cocoa products versus low-flavanol products or placebo in adults with or without hypertension when consumed for two weeks or longer. This is an updated version of the review initially published in 2012. In this updated version, we searched the following electronic databases from inception to November 2016: Cochrane Hypertension Group Specialised Register, CENTRAL, MEDLINE and Embase. We also searched international trial registries, and the reference lists of review articles and included trials. Randomised controlled trials (RCTs) investigating the effects of chocolate or cocoa products on systolic and diastolic blood pressure in adults for a minimum of two weeks duration. Two review authors independently extracted data and assessed the risks of bias in each trial. We conducted random-effects meta-analyses on the included studies using Review Manager 5. We explored heterogeneity with subgroup analyses by baseline blood pressure, flavanol content of control group, blinding, age and duration. Sensitivity analyses explored the influence of unusual study design. Thirty-five trials (including 40 treatment comparisons) met the inclusion criteria. Of these, we added 17 trials (20 treatment comparisons) to the 18 trials (20 treatment comparisons) in the previous version of this updated review.Trials provided participants with 30 to 1218 mg of flavanols (mean = 670 mg) in 1.4 to 105

  17. Blood Pressure Percentiles for School Children

    Directory of Open Access Journals (Sweden)

    İsmail Özanli

    2016-06-01

    Full Text Available Objective: The prevalence of hypertension in childhood and adolescence is gradually increasing. We aimed to in­vestigate the blood pressure (BP values of children aged 7-18 years. Methods: This study was conducted in a total of 3375 (1777 females, 1598 males children from 27 schools. Blood pressures of children were measured using sphyg­momanometer appropriate to arm circumference. Results: A positive relationship was found between sys­tolic blood pressure (SBP and diastolic blood pressure (DBP and the body weight, height, age and body mass index (BMI in male and female children. SBP was high­er in males than females after the age of 13. DBP was higher in males than the females after the age of 14. The mean annual increase of SBP was 2.06 mmHg in males and 1.54 mmHg in females. The mean annual increase of DBP was 1.52 mmHg in males and 1.38 mmHg in fe­males. Conclusion: In this study, we identified the threshold val­ues for blood pressure in children between the age of 7 and 18 years in Erzurum province. It is necessary to com­bine and evaluate data obtained from various regions for the identification of BP percentiles according to the age, gender and height percentiles of Turkish children.

  18. Insight of Human Stroke from blood flow and blood pressure

    Science.gov (United States)

    Chen, Zhi; Ivanov, Plamen Ch.; Hu, Kun; Stanley, H. Eugene

    2003-03-01

    Stroke is is one of the leading cause of death and disability in the world. It is well believed that stroke is caused by the disturbance of cerebrovascular autoregulation. We investigate the blood flow on the left and right middle cerebral artery and beat-to-beat blood pressure simultaneously measured from the finger, for both subjects with stroke and healthy subjects. Synchronization technique is used to distinguish the difference between these two groups.

  19. [Central blood pressure and vascular damage].

    Science.gov (United States)

    Pérez-Lahiguera, Francisco; Rodilla, Enrique; Costa, José Antonio; Pascual, José María

    2015-07-20

    The aim of this study was to assess the relationship between central blood pressure and vascular damage. This cross-sectional study involved 393 never treated hypertensive patients (166 women). Clinical blood pressure (BP), 24h blood pressure (BP24h) and central blood pressure (CBP) were measured. Vascular organ damage (VOD) was assessed by calculating the albumin/creatinine ratio (ACR), wave pulse pressure velocity and echocardiographic left ventricular mass index (LVMI). Patients with VOD had higher values of BP, BP24h, and CBP than patients without ACR. When comparing several systolic BP, systolic BP24h had a higher linear correlation with CBP (Z Steiger test: 2.26; P=.02) and LVMI (Z Steiger test: 3.23; P=.01) than PAC. In a multiple regression analysis corrected by age, sex and metabolic syndrome, all pressures were related with VOD but systolic BP24h showed the highest correlation. In a logistic regression analysis, having the highest tercile of systolic BP24h was the stronger predictor of VOD (multivariate odds ratio: 3.4; CI 95%: 2.5-5.5, P=.001). CBP does not have more correlation with VOD than other measurements of peripheral BP. Systolic BP24h is the BP measurement that best predicts VOD. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.

  20. The diagnostic value of supine blood pressure in hypertension.

    Science.gov (United States)

    Krzesiński, Paweł; Stańczyk, Adam; Gielerak, Grzegorz; Piotrowicz, Katarzyna; Banak, Małgorzata; Wójcik, Agnieszka

    2016-04-01

    Correct blood pressure (BP) measurement is crucial in the diagnosis of arterial hypertension (AH), and controversy exists whether supine BP should be treated as equal to sitting BP. The aim of this study was to evaluate the relation of supine BP to sitting BP and ambulatory BP with regard to identification of diagnostic cut-offs for hypertension. This study included 280 patients with AH (mean age: 44.3 ±10.6 years). The following measurements of BP were performed and analyzed: 1) sitting office blood pressure measurement (OSBP and ODBP); 2) supine BP (supSBP and supDBP), measured automatically (5 times with a 2-minute interval) during evaluation by the Niccomo device (Medis, Germany); 3) 24-hour ambulatory blood pressure (ABP) monitoring. The mean supSBP and supDBP were found to be lower than OSBP and ODBP (130.9 ±14.2 vs. 136.6 ±15.5 mm Hg and 84.8 ±9.4 vs. 87.8 ±10.2 mm Hg, respectively; p AUC: 0.820 vs. 0.550; sensitivity 80.7% vs. 57.4%; specificity 83.2% vs. 52.7%; p blood pressure during a 10-minute supine rest was lower than in the sitting position. The supine blood pressure ≥ 130/80 mm Hg was found to be a specific and sensitive threshold for hypertension.

  1. Letter to editor: Blood pressure, hypertension and lead exposure.

    Science.gov (United States)

    Yang, Wen-Yi; Staessen, Jan A

    2018-02-19

    A significant association of office diastolic blood pressure with low-level blood lead exposure was reported in a Brazilian adult population. However, caution should be taken to interpret these results. The multivariable-adjusted association with blood pressure was positive for diastolic blood pressure, but inverse for systolic blood pressure. The association sizes were infinitesimal without clinical relevance. The outcome measures, i.e. blood pressure and the prevalence of hypertension were analysed across categories of the blood lead distribution - not in relation to blood lead as continuous variable. Blood pressure was the average of two oscillometric office readings, whereas ambulatory monitoring is the state-of-the-art.

  2. Contribution of a winged phlebotomy device design to blood splatter.

    Science.gov (United States)

    Haiduven, Donna J; McGuire-Wolfe, Christine; Applegarth, Shawn P

    2012-11-01

    Despite a proliferation of phlebotomy devices with engineered sharps injury protection (ESIP), the impact of various winged device designs on blood splatter occurring during venipuncture procedures has not been explored. To evaluate the potential for blood splatter of 6 designs of winged phlebotomy devices. A laboratory-based device evaluation without human subjects, using a simulated patient venous system. We evaluated 18 winged phlebotomy devices of 6 device designs by Terumo, BD Vacutainer (2 designs), Greiner, Smith Medical, and Kendall (designated A-F, respectively). Scientific filters were positioned around the devices and weighed before and after venipuncture was performed. Visible blood on filters, exam gloves, and devices and measurable blood splatter were the primary units of analysis. The percentages of devices and gloves with visible blood on them and filters with measurable blood splatter ranged from 0% to 20%. There was a statistically significant association between device design and visible blood on devices ([Formula: see text]) and between device design and filters with measurable blood splatter ([Formula: see text]), but not between device design and visible blood on gloves. A wide range of associations were demonstrated between device design and visible blood on gloves or devices and incidence of blood splatter. The results of this evaluation suggest that winged phlebotomy devices with ESIP may produce blood splatter during venipuncture. Reinforcing the importance of eye protection and developing a methodology to assess ocular exposure to blood splatter are major implications for healthcare personnel who use these devices. Future studies should focus on evaluating different designs of intravascular devices (intravenous catheters, other phlebotomy devices) for blood splatter.

  3. Blood pressure in childhood : epidemiological probes into the aetiology of high blood pressure

    NARCIS (Netherlands)

    A. Hofman (Albert)

    1983-01-01

    textabstractHigh arterial blood pressure takes a heavy toll in western populations (1 ). Its causes are still largely unknown, but its sequelae, a variety of cardiovascular and renal diseases, have been referred to as "a modern scourge" (2). High blood pressure of unknown cause, or

  4. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  5. [Ambulatory blood pressure monitoring (ABPM) in elderly].

    Science.gov (United States)

    Palade, D; Iliescu, D; Cotârleţ, Laura; Pandele, G I

    2010-01-01

    Comparison of blood pressure values measured by two methods. 94 hypertensive patients (66 women and 28 men in relation to 2.36/1) were assessed classically and also by ABPM. For statistic evaluation we have used t - Student test, chi2 test, Pearson correlation coefficient and variation coefficient (cv%). It shows significant differences between mean values of systolic and diastolic blood pressure obtained by the 2 methods. ABPM measured values are more accurate compared to clinic, bringing also information on pattern hypertensive therapy.

  6. Predictive role of the nighttime blood pressure

    DEFF Research Database (Denmark)

    Hansen, Tine W; Li, Yan; Boggia, José

    2011-01-01

    Numerous studies addressed the predictive value of the nighttime blood pressure (BP) as captured by ambulatory monitoring. However, arbitrary cutoff limits in dichotomized analyses of continuous variables, data dredging across selected subgroups, extrapolation of cross-sectional studies...... of conclusive evidence proving that nondipping is a reversible risk factor, the option whether or not to restore the diurnal blood pressure profile to a normal pattern should be left to the clinical judgment of doctors and should be individualized for each patient. Current guidelines on the interpretation...

  7. [Blood pressure and polycystic ovary syndrome (PCOS)].

    Science.gov (United States)

    Kiałka, Marta; Milewicz, Tomasz; Klocek, Marek

    2015-01-01

    Polycystic ovary syndrome (PCOS) is the most common endocrine disorder occurring in women of childbearing age. The literature describes the relationship between PCOS and high blood pressure levels and increased risk of arterial hypertension development, which is an important and strong risk factor for adverse cardiovascular events in the future. Among the main causes of hypertension in PCOS women insulin resistance, hyperandrogenism, greater sympathetic nerve activity and concomitance of obesity are stressed. Because PCOS may contribute to earlier development of hypertension, as well as pre-hypertension, therefore it is advisable to monitor blood pressure systematically, to control known risk factors, and to initiate the treatment of hypertension when the disease occur.

  8. Effect of fenofibrate on blood pressure reduction

    Directory of Open Access Journals (Sweden)

    A K Lipatenkova

    2013-03-01

    Full Text Available Реферат по материалам статей 1. Gilbert K, Nian H, Yu C, Luther JM, Brown NJ. Fenofibrate lowers blood pressure in salt-sensitive but not salt-resistant hypertension. J Hypertens. 2013 Apr;31(4:820-9. doi: 10.1097/HJH.0b013e32835e8227. 2. Kwang K. K. Does Fenofibrate Lower Blood Pressure? Hypertension. 2013 Mar;61(3:e27. doi: 10.1161/HYPERTENSIONAHA.111.00792.

  9. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  10. Radioisotope method for assessing skin blood pressure

    International Nuclear Information System (INIS)

    Tarkowska, A.; Misiunia, P.; Woytowicz, A.; Olewinski, T.

    1979-01-01

    A method of measuring the skin blood pressure (SBP) evolved by Holstein and Lassen is described. The method is based on determination of the force of pressure causing blockade of Na 131 I clearance from the site of its intradermal injection. Using this method it was found that in the lower extremities in healthy subjects the SBP approached the diastolic pressure measured by the conventional method in the brachial artery. On the other hand in patients with obliterative arteriosclerosis and in Buerger's disease the SBP was considerably lower than the diastolic arterial pressure. The authors think that the method gives a good insight into the state of blood supply to the extremities in healthy subjects and in peripheral vascular failure. (author)

  11. Pressure measurements in magnetic-fusion devices

    International Nuclear Information System (INIS)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration

  12. Pressure measurements in magnetic-fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration.

  13. Blood pressure control among type 2 diabetics

    International Nuclear Information System (INIS)

    Al-Shehri, Ahmed M.

    2008-01-01

    Objective was to assess blood pressure BP control in patients with diabetes mellitus type 2 DM type treated in primary health care. A cross-sectional study was conducted in primary health care at King Fahd Military Complex Hospital in Dhahran, Kingdom of Saudi Arabia, between August 2003 and February 2004, to assess blood control in type 2 diabetics. A sample of 403 medical records of type 2 diabetic patients was selected using systematic random sampling after ordering the medical record numbers. The data were collected through the pre-coded checklist. Hypertension was found in 57.8% of diabetic patients with no statistically significant difference between males and females. The mean age of diabetic patients was significantly highly in hypertensive than non-hypertensive p=0.001. The mean duration of hypertension was significantly higher in females p=0.02. There were only 14.2% of hypertensive diabetic patients in whom blood pressure was controlled. Poor control was significantly associated with obesity and a high rate of complications. Blood pressure control correlated positively and significantly with the age of patients and negatively with duration of diabetes and hypertension. The most commonly prescribed antihypertensive were angiotensin converting enzyme inhibitors in 29.3%, followed by angiotensin receptors blockers in 24.1%, and the least prescribed drug was thiazide diuretic. Blood pressure in diabetic patients needs to be given particular attention from all health care professionals, especially primary care family physicians, who should follow the new guideline for better control of blood pressure, and fewer complications. Patient's awareness should be increased, through continuous health education with different modalities. (author)

  14. The association between smoking and blood pressure in men: a cross-sectional study.

    Science.gov (United States)

    Li, Guoju; Wang, Hailing; Wang, Ke; Wang, Wenrui; Dong, Fen; Qian, Yonggang; Gong, Haiying; Hui, Chunxia; Xu, Guodong; Li, Yanlong; Pan, Li; Zhang, Biao; Shan, Guangliang

    2017-10-10

    Cigarette smoking is a known risk factor for cardiovascular disease (CVD), but the association between smoking and blood pressure is unclear. Thus, the current study examined the association between cigarette smoking and blood pressure in men. Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) and pulse pressure (PP) were examined using digital blood pressure measuring device, and smoking status was determined with China National Health Survey. The ANCOVA showed that the adjusted DBP and MAP were lower in current smokers versus nonsmokers and the adjusted SBP was lower in current smokers versus former smokers (P smoking on blood pressure indices except PP was observed. Smoking cessation was significantly associated with an increased risk of hypertension. However, current smoking was not a risk factor of hypertension.

  15. Dysglycemia induces abnormal circadian blood pressure variability

    Directory of Open Access Journals (Sweden)

    Kumarasamy Sivarajan

    2011-11-01

    Full Text Available Abstract Background Prediabetes (PreDM in asymptomatic adults is associated with abnormal circadian blood pressure variability (abnormal CBPV. Hypothesis Systemic inflammation and glycemia influence circadian blood pressure variability. Methods Dahl salt-sensitive (S rats (n = 19 after weaning were fed either an American (AD or a standard (SD diet. The AD (high-glycemic-index, high-fat simulated customary human diet, provided daily overabundant calories which over time lead to body weight gain. The SD (low-glycemic-index, low-fat mirrored desirable balanced human diet for maintaining body weight. Body weight and serum concentrations for fasting glucose (FG, adipokines (leptin and adiponectin, and proinflammatory cytokines [monocyte chemoattractant protein-1 (MCP-1 and tumor necrosis factor-α (TNF-α] were measured. Rats were surgically implanted with C40 transmitters and blood pressure (BP-both systolic; SBP and diastolic; DBP and heart rate (HR were recorded by telemetry every 5 minutes during both sleep (day and active (night periods. Pulse pressure (PP was calculated (PP = SBP-DBP. Results [mean(SEM]: The AD fed group displayed significant increase in body weight (after 90 days; p Conclusion These data validate our stated hypothesis that systemic inflammation and glycemia influence circadian blood pressure variability. This study, for the first time, demonstrates a cause and effect relationship between caloric excess, enhanced systemic inflammation, dysglycemia, loss of blood pressure control and abnormal CBPV. Our results provide the fundamental basis for examining the relationship between dysglycemia and perturbation of the underlying mechanisms (adipose tissue dysfunction induced local and systemic inflammation, insulin resistance and alteration of adipose tissue precursors for the renin-aldosterone-angiotensin system which generate abnormal CBPV.

  16. Stress and High Blood Pressure: What's the Connection?

    Science.gov (United States)

    Stress and high blood pressure: What's the connection? Stress and long-term high blood pressure may not be linked, but taking steps to reduce your stress can improve your general health, including your blood ...

  17. Self-monitored blood pressure: a role in clinical practice?

    Science.gov (United States)

    Padfield, Paul L

    2002-02-01

    Electronic self-monitoring of blood pressure is increasing in popularity and most international guidelines on the management of hypertension approve cautious use of the technique in the assessment of potentially hypertensive individuals. A recent editorial in the Archives of Internal Medicine suggested that it was "appropriate to encourage the widespread use of self recorded BP as an important adjunct to the clinical care of the patient with hypertension". Such a statement is based on increasing evidence that self-monitoring of blood pressure gives similar information to daytime ambulatory blood pressure -- a now well-established technology in the management of hypertension. Suggested strategies for the use of self-monitoring of blood pressure include monitoring in individuals whose clinical risk status is low enough that they need not necessarily be given medical therapy simply on the basis of a clinic pressure (i.e. at a 10 year risk of cardiovascular disease below 20%). The threshold for defining 'normotension/hypertension' is now regarded as being broadly similar for ABPM and SBPM and is set at 135/85 mmHg. In a recent meta-analysis of all available studies the average difference between these techniques, using the same patients, is -1.7/1.2 mmHg. There is some evidence that careful use of self-monitoring may improve blood pressure control in patients who are otherwise resistant to care. Self-monitoring of blood pressure has now been shown in at least one major prospective study to predict outcome better than clinic pressures and in that setting it now has equivalence to the use of ABPM. There remain issues regarding the availability of validated devices, the quality of training of patients in their use and the possibility that inaccurate recording might occur, either deliberately or by accident. Self-monitoring of blood pressure may well not give the same readings as carefully measured blood pressure by research nurses but its use is clearly superior to

  18. Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device.

    Science.gov (United States)

    Al-Karkhi, Isam; Al-Rubaiy, Raad; Rosenqvist, Ulf; Falk, Magnus; Nystrom, Fredrik H

    2015-04-01

    We aimed to compare blood pressure (BP) levels recorded using the semiautomatic oscillometric Omron i-C10 BP device in patients with or without hypertension in three different settings: (a) when used by a doctor or a nurse at the office (OBP); (b) when used for self-measurement by the patient at the office (SMOBP); and (c) when used for 7 consecutive days at home (HBP). A total of 247 individuals were invited to participate, but 78 of these individuals declined and a further seven were excluded, leaving a final cohort of 162 participants. The mean OBP was higher than HBP (difference 8.1±14/3.1±8.8 mmHg, P<0.0001) and so was SMOBP compared with HBP (difference 7.0±13/4.2±7.3 mmHg, P<0.0001). Sixteen participants (9.9%) had at least 10 mmHg higher systolic SMOBP than OBP and 28 (17%) participants had at least 10 mmHg lower systolic SMOBP than OBP. Participants who were current smokers had a larger mean difference between systolic OBP and SMOBP than nonsmokers (OBP-SMOBP in smokers: 6.6±9.4 mmHg, OBP-SMOBP in nonsmokers: 0.5±9.2 mmHg, P=0.011 between groups). Self-measurement of BP in the office does not preclude an increase in BP when levels in the individual patients are compared with HBP using the same equipment. Thus, SMOBP with a semiautomatic device does not lead to a reduction in the white-coat effect in the same manner as fully automatic devices.

  19. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  20. Teaming Up Against High Blood Pressure

    Centers for Disease Control (CDC) Podcasts

    2012-09-04

    This podcast is based on the September 2012 CDC Vital Signs report. A team-based approach by patients, health care systems, and health care providers is one of the best ways to treat uncontrolled high blood pressure.  Created: 9/4/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 9/4/2012.

  1. Dietary protein, blood pressure and mortality

    NARCIS (Netherlands)

    Tielemans, S.M.A.J.

    2016-01-01

    Cardiovascular diseases (CVD) are the main cause of death worldwide. In 2012, about 17.5 million people died from CVD, accounting for 30% of all deaths. High blood pressure (BP) is a major cardiovascular risk factor, which was responsible for 10.4 million deaths in 2013. Diet and lifestyle play

  2. Neighborhood Disadvantage and Variations in Blood Pressure

    Science.gov (United States)

    Cathorall, Michelle L.; Xin, Huaibo; Peachey, Andrew; Bibeau, Daniel L.; Schulz, Mark; Aronson, Robert

    2015-01-01

    Purpose: To examine the extent to which neighborhood disadvantage accounts for variation in blood pressure. Methods: Demographic, biometric, and self-reported data from 19,261 health screenings were used. Addresses of participants were geocoded and located within census block groups (n = 14,510, 75.3%). Three hierarchical linear models were…

  3. Casual blood pressure among Tanzanian undergraduate students ...

    African Journals Online (AJOL)

    Background: Despite of the recommendations to use population specific blood pressure (BP) references which consider time, ethnicity and environmental factors, there is limited information regarding BP profile among Tanzanians. This cross sectional study was done to determine casual BP profile among healthy volunteer ...

  4. Intrathoracic Pressure Regulator for Blood Loss

    Science.gov (United States)

    2016-05-24

    hepatitis A antibody, and human immunodeficiency virus antibody), urine tests (drug screen I-abuse, marijuana, and a pregnancy test), and a 12-lead... sodium chloride; 250 mL over 2.5 minutes) were administered if systolic BP < 85 mmHg. Blood pressure, other hemodynamics, UO, and total amount of

  5. Ethnic Variations in Blood Pressure and Hypertension

    NARCIS (Netherlands)

    C.O. Agyemang (Charles)

    2005-01-01

    textabstractThe objective of the study was to review published evidence on whether blood pressure levels and the prevalence of hypertension are higher or lower in South Asian adults living in the UK as compared to white populations. A systematic literature review was carried out using MEDLINE

  6. Association between blood Pressure, waist circumference ...

    African Journals Online (AJOL)

    Objective: Blood pressure (BP) is one of the main cardiovascular risk indicators, but studies on its relationship with waist circumference, triglycerides and cholesterol are rare in low and middle income countries and even non-existent in some areas like the north of Cameroon. The aim of our study was to determine the ...

  7. Hybrid optical unobtrusive blood pressure measurements

    NARCIS (Netherlands)

    Zhang, G.; Shan, C.; Kirenko, I.; Long, X.; Aarts, R.M.

    2017-01-01

    Blood pressure (BP) is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT) calculated by a pair of photoplethysmography (PPG) signals at two body sites. Currently, contact PPG (cPPG) and

  8. Blood pressure modifies retinal susceptibility to intraocular pressure elevation.

    Directory of Open Access Journals (Sweden)

    Zheng He

    Full Text Available Primary open angle glaucoma affects more than 67 million people. Elevated intraocular pressure (IOP is a risk factor for glaucoma and may reduce nutrient availability by decreasing ocular perfusion pressure (OPP. An interaction between arterial blood pressure and IOP determines OPP; but the exact contribution that these factors have for retinal function is not fully understood. Here we sought to determine how acute modifications of arterial pressure will affect the susceptibility of neuronal function and blood flow to IOP challenge. Anaesthetized (ketamine:xylazine Long-Evan rats with low (∼60 mmHg, sodium nitroprusside infusion, moderate (∼100 mmHg, saline, or high levels (∼160 mmHg, angiotensin II of mean arterial pressure (MAP, n = 5-10 per group were subjected to IOP challenge (10-120 mmHg, 5 mmHg steps every 3 minutes. Electroretinograms were measured at each IOP step to assess bipolar cell (b-wave and inner retinal function (scotopic threshold response or STR. Ocular blood flow was measured using laser-Doppler flowmetry in groups with similar MAP level and the same IOP challenge protocol. Both b-wave and STR amplitudes decreased with IOP elevation. Retinal function was less susceptible to IOP challenge when MAP was high, whereas the converse was true for low MAP. Consistent with the effects on retinal function, higher IOP was needed to attenuated ocular blood flow in animals with higher MAP. The susceptibility of retinal function to IOP challenge can be ameliorated by acute high BP, and exacerbated by low BP. This is partially mediated by modifications in ocular blood flow.

  9. Miniaturized Blood Pressure Telemetry System with RFID Interface

    Directory of Open Access Journals (Sweden)

    Michele Caldara

    2016-08-01

    Full Text Available This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID tag, International Organization for Standardization (ISO 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure wave undergoes embedded processing and results are stored onboard in a non-volatile memory, providing the data under interrogation by an external RFID reader. In order to extend battery lifetime, RFID energy harvesting has been investigated. The paper presents the experimental characterization in a laboratory and preliminary in-vivo tests. The device is a prototype mainly intended, in a future engineered version, for monitoring freely moving test animals for pharmaceutical research and drug safety assessment purposes, but it could have multiple uses in environmental and industrial applications.

  10. Implantable blood pressure sensor for analyzing elasticity in arteries

    Science.gov (United States)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  11. Changes You Can Make to Manage High Blood Pressure

    Science.gov (United States)

    ... about Bayer Consumer Health. HBP Resources Risk Calculator Animation Library Track Your Blood Pressure: Print (PDF) | Online ... Pressure Tracker Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  12. Effects of endurance training on blood pressure, blood pressure-regulating mechanisms, and cardiovascular risk factors.

    Science.gov (United States)

    Cornelissen, Véronique A; Fagard, Robert H

    2005-10-01

    Previous meta-analyses of randomized controlled trials on the effects of chronic dynamic aerobic endurance training on blood pressure reported on resting blood pressure only. Our aim was to perform a comprehensive meta-analysis including resting and ambulatory blood pressure, blood pressure-regulating mechanisms, and concomitant cardiovascular risk factors. Inclusion criteria of studies were: random allocation to intervention and control; endurance training as the sole intervention; inclusion of healthy sedentary normotensive or hypertensive adults; intervention duration of > or =4 weeks; availability of systolic or diastolic blood pressure; and publication in a peer-reviewed journal up to December 2003. The meta-analysis involved 72 trials, 105 study groups, and 3936 participants. After weighting for the number of trained participants and using a random-effects model, training induced significant net reductions of resting and daytime ambulatory blood pressure of, respectively, 3.0/2.4 mm Hg (Phypertensive study groups (-6.9/-4.9) than in the others (-1.9/-1.6; Pendurance training decreases blood pressure through a reduction of vascular resistance, in which the sympathetic nervous system and the renin-angiotensin system appear to be involved, and favorably affects concomitant cardiovascular risk factors.

  13. Blood pressure and control of cardiovascular risk

    Directory of Open Access Journals (Sweden)

    Judith A Whitworth

    2005-10-01

    Full Text Available Judith A WhitworthJohn Curtin School of Medical Research, Australian National University, Canberra, ACT, AustraliaAbstract: Two key early 20th century notions, the first the primacy of diastolic pressure in determining risk, and the second that hypertension is a discrete disorder, have proved to be incorrect. We now recognize the primacy of systolic pressure as a risk factor for cardiovascular disease and that hypertension is an arbitrary definition. In the early 21st century, we are moving away from a dichotomous approach to risk classification, and away from notions of hypertension and normotension towards an appreciation that blood pressure-related risk is continuous. In parallel, there has been a paradigm shift from a single risk factor approach to comprehensive cardiovascular disease risk prevention. Accordingly, prevention of cardiovascular disease requires a focus on lowering of blood pressure and modification of associated risk factors rather than simply treatment of hypertension. This emphasis is reflected in the World Health Organization (WHO – International Society of Hypertension (ISH 2003 statement on management of hypertension.Keywords: blood pressure, hypertension, cardiovascular risk, treatment

  14. Prevalence of end-digit preference in recorded blood pressure by ...

    African Journals Online (AJOL)

    2012-03-15

    Mar 15, 2012 ... (BP) measuring device eliminates the risk of exposure to mercury. ... Results: There was a large and significant fall in end-digit zero when BP readings that were ..... positioning, an inadequate rest period and the posture of the .... electronic blood pressure measurement influence recorded blood pressure?

  15. Office blood pressure or ambulatory blood pressure for the prediction of cardiovascular events.

    Science.gov (United States)

    Mortensen, Rikke Nørmark; Gerds, Thomas Alexander; Jeppesen, Jørgen Lykke; Torp-Pedersen, Christian

    2017-11-21

    To determine the added value of (i) 24-h ambulatory blood pressure relative to office blood pressure and (ii) night-time ambulatory blood pressure relative to daytime ambulatory blood pressure for 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. A total of 7927 participants were included from the International Database on Ambulatory blood pressure monitoring in relation to Cardiovascular Outcomes. We used cause-specific Cox regression to predict 10-year person-specific absolute risks of fatal and non-fatal cardiovascular events. Discrimination of 10-year outcomes was assessed by time-dependent area under the receiver operating characteristic curve (AUC). No differences in predicted risks were observed when comparing office blood pressure and ambulatory blood pressure. The median difference in 10-year risks (1st; 3rd quartile) was -0.01% (-0.3%; 0.1%) for cardiovascular mortality and -0.1% (-1.1%; 0.5%) for cardiovascular events. The difference in AUC (95% confidence interval) was 0.65% (0.22-1.08%) for cardiovascular mortality and 1.33% (0.83-1.84%) for cardiovascular events. Comparing daytime and night-time blood pressure, the median difference in 10-year risks was 0.002% (-0.1%; 0.1%) for cardiovascular mortality and -0.01% (-0.5%; 0.2%) for cardiovascular events. The difference in AUC was 0.10% (-0.08 to 0.29%) for cardiovascular mortality and 0.15% (-0.06 to 0.35%) for cardiovascular events. Ten-year predictions obtained from ambulatory blood pressure are similar to predictions from office blood pressure. Night-time blood pressure does not improve 10-year predictions obtained from daytime measurements. For an otherwise healthy population sufficient prognostic accuracy of cardiovascular risks can be achieved with office blood pressure. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  16. Studies Comparing Ambulatory Blood Pressure and Home Blood Pressure on Cardiovascular Disease and Mortality Outcomes: A Systematic Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Ambulatory blood pressure monitoring (ABPM) is more commonly recommended for assessing out-of-clinic blood pressure than home blood pressure monitoring (HBPM). We conducted a systematic review to examine whether ABPM or HBPM is more strongly associated with cardiovascular disease events and/or mortality. Of 1,007 abstracts published through July 20, 2015, nine articles, reporting results from seven cohorts, were identified. After adjustment for blood pressure on HBPM, blood pressure on ABPM was associated with an increased risk of outcomes in two of four cohorts for systolic blood pressure and two of three cohorts for diastolic blood pressure. After adjustment for blood pressure on ABPM, systolic blood pressure on HBPM was associated with outcomes in zero of three cohorts; an association was present in one of two cohorts for diastolic blood pressure on HBPM. There is a lack of strong empiric evidence supporting ABPM or HBPM over the other approach for predicting cardiovascular events or mortality. PMID:26822864

  17. Blood pressure changes in dogs with babesiosis

    Directory of Open Access Journals (Sweden)

    L.S. Jacobson

    2000-07-01

    Full Text Available Systemic arterial blood pressures were measured in 30 dogs with acute babesiosis, 10 each with mild uncomplicated, severe uncomplicated and complicated disease. Ten healthy dogs were used as controls. Hypotension was defined as more than 3 standard deviations below the control mean. Normal mean pressures (±SD were: systolic arterial pressure 151 (±11 mm Hg, diastolic arterial pressure 89 (±8 mm Hg and mean arterial pressure 107 (±10 mmHg. Hypotension was the most frequent abnormality, and increased strikingly in incidence as disease severity increased, with 5/10 dogs in the complicated group being hypotensive for systolic, diastolic and mean arterial pressures, compared with 2/10 in the severe uncomplicated group and 0/10 in the mild uncomplicated group. Systolic, diastolic and mean arterial pressures in the complicated group and severe uncomplicated group, and systolic pressure in the mild uncomplicated group, were significantly lower than in the controls. There were no significant relationships between arterial pressures and age, pulse rate, respiratory rate, temperature, mucous membrane colour or haematocrit. There was a significant negative correlation between arterial pressures and white cell and immature neutrophil counts. Arterial pressures differed significantly between dogs that were clinically collapsed and those that were not, but not between survivors and non-survivors. Pulse pressure (systolic - diastolic was low in 7/10 complicated, 1/10 mild uncomplicated, and 1/10 severe uncomplicated cases, and differed significantly between the complicated and control groups. The high incidence of hypotension in clinically severe babesiosis has important implications for therapy.

  18. An Implantable Intravascular Pressure Sensor for a Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Luigi Brancato

    2016-08-01

    Full Text Available The aim of this study is to investigate the intravascular application of a micro-electro-mechanical system (MEMS pressure sensor to directly measure the hemodynamic characteristics of a ventricular assist device (VAD. A bio- and hemo-compatible packaging strategy is implemented, based on a ceramic thick film process. A commercial sub-millimeter piezoresistive sensor is attached to an alumina substrate, and a double coating of polydimethylsiloxane (PDMS and parylene-C is applied. The final size of the packaged device is 2.6 mm by 3.6 mm by 1.8 mm. A prototype electronic circuit for conditioning and read-out of the pressure signal is developed, satisfying the VAD-specific requirements of low power consumption (less than 14.5 mW in continuous mode and small form factor. The packaged sensor has been submitted to extensive in vitro tests. The device displayed a temperature-independent sensitivity (12 μ V/V/mmHg and good in vitro stability when exposed to the continuous flow of saline solution (less than 0.05 mmHg/day drift after 50 h. During in vivo validation, the transducer has been successfully used to record the arterial pressure waveform of a female sheep. A small, intravascular sensor to continuously register the blood pressure at the inflow and the outflow of a VAD is developed and successfully validated in vivo.

  19. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  20. Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension.

    Science.gov (United States)

    Manning, Gillian; Donnelly, Richard

    2005-11-01

    Use of home blood-pressure monitoring is increasing but the technique and the equipment have limitations. We provide an overview of recent evidence in this rapidly evolving field. Home blood-pressure monitoring is an acceptable method for screening patients for hypertension. There is increasing evidence supporting the predictive power of home blood pressure for stroke risk even in the general population. The identification of white-coat and masked hypertension remains an important role for home blood-pressure monitoring. Unvalidated equipment and poor patient technique are major concerns. The purchase of devices needs to be linked to a simple patient-education programme, which is perhaps an opportunity for collaboration between healthcare providers and commercial companies. Devices that store the blood-pressure measurements in the memory are preferred to ensure accuracy of reporting. Data-transmission systems providing automatic storage, transmission and reporting of blood pressure, direct involvement of the patient and potentially a reduced number of hospital/general practitioner visits, offer significant advantages. To reduce patient anxiety, overuse of home blood-pressure monitoring should be avoided but there is the potential for self-modification of treatment, subject to certain safeguards. Self-monitoring of blood pressure is developing rapidly, linked to increasing awareness of the impact of reducing high blood pressure on public health and the marketing/advertising strategies used to sell automatic devices. Home blood-pressure monitoring has a role in the detection and management of blood pressure, but not at the expense of careful blood-pressure measurement in the office and adherence to national guidelines.

  1. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ogawa, Masahide.

    1993-01-01

    The present invention concerns a control rod driving hydraulic device of a BWR type reactor, and provides an improvement for a means for supplying mechanical seal flashing water of a pump. That is, a mechanical seal flashing pipeline is branched at the downstream of a pressure-reducing orifice and connected to a minimum flow pipeline. With such a constitution, the minimum flow pipeline is connected to a minimum flow pipeline of an auxiliary pump at the downstream of the pressure-reducing orifice and returned to a suction pipeline of the pump. Pressure at the downstream of the pressure-reducing orifice is set, in the orifice, to a pressure required for mechanical seal flashing. Accordingly, the mechanical seal flashing pipeline is connected and a part of minimum flow rate is utilized, thereby enabling to cool mechanical seals. As a result, flow rate of the mechanical flashing water which has been flown out can be saved. The exhaustion amount from the pump can be reduced, to decrease the shaft power and reduce the capacity of the motor. (I.S.)

  2. Validation of the Kingyield BP210 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension-International Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Huang, Qi-Fang; Sheng, Chang-Sheng; Li, Yan; Wang, Ji-Guang

    2012-02-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor BP210 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese participants (21 women, 51 years of mean age) using a mercury sphygmomanometer (two observers) and the BP210 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 15 participants in phase 1 and a further 18 participants in phase 2 of the validation study. Data analysis was conducted using the ESHIP analyzer. The BP210 device successfully passed phase 1 of the validation study with a number of absolute differences between device and observers within 5, 10, and 15 mmHg for at least 33/45, 44/45, and 44/45 measurements, respectively. The device also achieved the targets for phase 2.1, with 77/99, 95/99, and 97/99 differences within 5, 10, and 15 mmHg, respectively for systolic blood pressure, and with 78/99, 97/99, and 99/99 within 5, 10, and 15 mmHg, respectively for diastolic blood pressure. In phase 2.2, 29 and 25 participants had at least two of the three device-observers differences within 5 mmHg (required≥22) for systolic blood pressure and diastolic blood pressure, respectively. The Kingyield wrist blood pressure monitor BP210 has passed the International Protocol requirements, and hence can be recommended for home use in adults.

  3. Alanine increases blood pressure during hypotension

    Science.gov (United States)

    Conlay, L. A.; Maher, T. J.; Wurtman, R. J.

    1990-01-01

    The effect of L-alanine administration on blood pressure (BP) during haemorrhagic shock was investigated using anesthetized rats whose left carotid arteries were cannulated for BP measurement, blood removal, and drug administration. It was found that L-alanine, in doses of 10, 25, 50, 100, and 200 mg/kg, increased the systolic BP of hypotensive rats by 38 to 80 percent (while 100 mg/kg pyruvate increased BP by only 9.4 mmhg, not significantly different from saline). The results suggest that L-alanine might influence cardiovascular function.

  4. Worldwide trends in blood pressure from 1975 to 2015

    DEFF Research Database (Denmark)

    Linneberg, Allan René; Sørensen, Thorkild I.A.

    2017-01-01

    BACKGROUND: Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood...... pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. METHODS: For this analysis, we pooled national, subnational, or community population-based studies that had measured blood pressure in adults aged 18 years and older. We used a Bayesian hierarchical model to estimate trends...... from 1975 to 2015 in mean systolic and mean diastolic blood pressure, and the prevalence of raised blood pressure for 200 countries. We calculated the contributions of changes in prevalence versus population growth and ageing to the increase in the number of adults with raised blood pressure. FINDINGS...

  5. Diagnosis of childhood hypertension: is blood pressure height ratio ...

    African Journals Online (AJOL)

    Blood pressure was also recorded according to the standard method. Systolic and diastolic blood pressure to height ratio were then calculated. Receiver operating curves was used to assess the ability of systolic blood and diastolic blood pressure height ratio to discriminate childhood prehypertension and hypertension.

  6. Ambulatory blood pressure monitoring-derived short-term blood pressure variability in primary hyperparathyroidism.

    Science.gov (United States)

    Concistrè, A; Grillo, A; La Torre, G; Carretta, R; Fabris, B; Petramala, L; Marinelli, C; Rebellato, A; Fallo, F; Letizia, C

    2018-04-01

    Primary hyperparathyroidism is associated with a cluster of cardiovascular manifestations, including hypertension, leading to increased cardiovascular risk. The aim of our study was to investigate the ambulatory blood pressure monitoring-derived short-term blood pressure variability in patients with primary hyperparathyroidism, in comparison with patients with essential hypertension and normotensive controls. Twenty-five patients with primary hyperparathyroidism (7 normotensive,18 hypertensive) underwent ambulatory blood pressure monitoring at diagnosis, and fifteen out of them were re-evaluated after parathyroidectomy. Short-term-blood pressure variability was derived from ambulatory blood pressure monitoring and calculated as the following: 1) Standard Deviation of 24-h, day-time and night-time-BP; 2) the average of day-time and night-time-Standard Deviation, weighted for the duration of the day and night periods (24-h "weighted" Standard Deviation of BP); 3) average real variability, i.e., the average of the absolute differences between all consecutive BP measurements. Baseline data of normotensive and essential hypertension patients were matched for age, sex, BMI and 24-h ambulatory blood pressure monitoring values with normotensive and hypertensive-primary hyperparathyroidism patients, respectively. Normotensive-primary hyperparathyroidism patients showed a 24-h weighted Standard Deviation (P blood pressure higher than that of 12 normotensive controls. 24-h average real variability of systolic BP, as well as serum calcium and parathyroid hormone levels, were reduced in operated patients (P blood pressure variability is increased in normotensive patients with primary hyperparathyroidism and is reduced by parathyroidectomy, and may potentially represent an additional cardiovascular risk factor in this disease.

  7. Renoprotection with and without blood pressure reduction

    DEFF Research Database (Denmark)

    Laverman, Gozewijn Dirk; Andersen, Steen; Rossing, Peter

    2005-01-01

    BACKGROUND: AT1-receptor blockade dose dependently lowers blood pressure (BP) and albuminuria. Reduction of BP and albuminuria are independent treatment targets for renoprotection, but whether this requires similar dose titration is unknown. METHODS: We tested this in two studies designed to find...... arterial pressure (MAP) were measured. Patients were divided into "good" and "poor" BP responders (BP+, BP-) according to BP response above or below group median. RESULTS: Baseline MAP in the BP- groups was 102 (97, 104) mm Hg in DM (median, 95% CI) and 91 (80, 108) mm Hg in ND. The top of the dose...

  8. Diurnal changes of blood pressure values (24 h blood pressures in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Barbara Grzechocińska

    2011-06-01

    Full Text Available Background: More attention is being paid lately to polycystic ovary syndrome (PCOS not only in the aspect of fertility but also according to long-term metabolic and cardiovascular abnormalities. Observations of women with PCOS show that the occurrence of blood hypertension is more frequent after the menopause. There are few articles concerning the predictable symptoms of blood hypertension. It seems that twenty-four hour blood pressure monitoring and assessment of changes of diurnal rhythm could be useful in this group of patients.Aim of the study: The purpose of this study was to assess diurnal changes of blood pressure in women with polycystic ovary syndrome.Material and methods: 26 women with PCOS diagnosed according to Rotterdam consensus criteria and Androgen Excess Society (AES criteria were included in our study. The mean age of the examined women was 29.5 years and the mean BMI (body mass index was 24.7 kg/m2. The control group consisted of 12 age-matched women, without PCOS. Twenty-four hour Holter monitoring of ambulatory blood pressure was performed during normal daily activity in all patients. Halberg’s cosinor method was used to analyse daily biorhythm.Results: Results show the diurnal changes of systolic blood pressure in the preclinical phase in 30% and diastolic in 15% of PCOS women. In this group no physiological decrease of blood pressure at night time was observed.

  9. Cocoa, blood pressure, and vascular function.

    Science.gov (United States)

    Sudano, Isabella; Flammer, Andreas J; Roas, Susanne; Enseleit, Frank; Ruschitzka, Frank; Corti, Roberto; Noll, Georg

    2012-08-01

    The consumption of a high amount of fruits and vegetables was found to be associated with a lower risk of coronary heart disease and stroke. Epidemiologically, a similar relationship has been found with cocoa, a naturally polyphenol-rich food. Obviously, double blind randomized studies are difficult to perform with cocoa and chocolate, respectively. However, intervention studies strongly suggest that cocoa has several beneficial effects on cardiovascular health, including the lowering of blood pressure, the improvement of vascular function and glucose metabolism, and the reduction of platelet aggregation and adhesion. Several potential mechanisms through which cocoa might exert its positive effects have been proposed, among them activation of nitric oxide synthase, increased bioavailability of nitric oxide as well as antioxidant, and anti-inflammatory properties. It is the aim of this review to summarize the findings of cocoa and chocolate on blood pressure and vascular function.

  10. Effect of lemon juice on blood pressure

    OpenAIRE

    SARI, Aysel; SELİM, Nevzat; DİLEK, Melda; AYDOĞDU, Turkan; ADIBELLİ, Zelal; BÜYÜKKAYA, Piltan; AKPOLAT, Tekin

    2012-01-01

    Lemon juice has commonly been used by hypertensive patients in order to lower blood pressure (BP) acutely when BP is raised or as an alternative/complementary therapy for expectation of chronic improvement. Grapefruit, a citrus fruit like lemon, causes clinically significant interactions with a variety of drugs including calcium antagonists. The aims of this study were to investigate acute and chronic effects of lemon juice on BP among hypertensive patients. Ninty-eight patients were included...

  11. Renal intercalated cells and blood pressure regulation

    Directory of Open Access Journals (Sweden)

    Susan M. Wall

    2017-12-01

    Full Text Available Type B and non-A, non-B intercalated cells are found within the connecting tubule and the cortical collecting duct. Of these cell types, type B intercalated cells are known to mediate Cl⁻ absorption and HCO₃⁻ secretion largely through pendrin-dependent Cl⁻/HCO₃⁻ exchange. This exchange is stimulated by angiotensin II administration and is also stimulated in models of metabolic alkalosis, for instance after aldosterone or NaHCO₃ administration. In some rodent models, pendrin-mediated HCO₃⁻ secretion modulates acid-base balance. However, the role of pendrin in blood pressure regulation is likely of more physiological or clinical significance. Pendrin regulates blood pressure not only by mediating aldosterone-sensitive Cl⁻ absorption, but also by modulating the aldosterone response for epithelial Na⁺ channel (ENaC-mediated Na⁺ absorption. Pendrin regulates ENaC through changes in open channel of probability, channel surface density, and channels subunit total protein abundance. Thus, aldosterone stimulates ENaC activity through both direct and indirect effects, the latter occurring through its stimulation of pendrin expression and function. Therefore, pendrin contributes to the aldosterone pressor response. Pendrin may also modulate blood pressure in part through its action in the adrenal medulla, where it modulates the release of catecholamines, or through an indirect effect on vascular contractile force. This review describes how aldosterone and angiotensin II-induced signaling regulate pendrin and the contributory role of pendrin in distal nephron function and blood pressure.

  12. Perinatal development and adult blood pressure

    Directory of Open Access Journals (Sweden)

    N. Ashton

    2000-07-01

    Full Text Available A growing body of evidence supports the concept of fetal programming in cardiovascular disease in man, which asserts that an insult experienced in utero exerts a long-term influence on cardiovascular function, leading to disease in adulthood. However, this hypothesis is not universally accepted, hence animal models may be of value in determining potential physiological mechanisms which could explain how fetal undernutrition results in cardiovascular disease in later life. This review describes two major animal models of cardiovascular programming, the in utero protein-restricted rat and the cross-fostered spontaneously hypertensive rat. In the former model, moderate maternal protein restriction during pregnancy induces an increase in offspring blood pressure of 20-30 mmHg. This hypertensive effect is mediated, in part, by fetal exposure to excess maternal glucocorticoids as a result of a deficiency in placental 11-ß hydroxysteroid dehydrogenase type 2. Furthermore, nephrogenesis is impaired in this model which, coupled with increased activity of the renin-angiotensin system, could also contribute to the greater blood pressure displayed by these animals. The second model discussed is the cross-fostered spontaneously hypertensive rat. Spontaneously hypertensive rats develop severe hypertension without external intervention; however, their adult blood pressure may be lowered by 20-30 mmHg by cross-fostering pups to a normotensive dam within the first two weeks of lactation. The mechanisms responsible for this antihypertensive effect are less clear, but may also involve altered renal function and down-regulation of the renin-angiotensin system. These two models clearly show that adult blood pressure is influenced by exposure to one of a number of stimuli during critical stages of perinatal development.

  13. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  14. Blood pressure changes during barium enema

    International Nuclear Information System (INIS)

    Roach, S.C.; Martin, O.J.D.; Owen, A.; Martin, D.F.

    2001-01-01

    AIMS: To document blood pressure changes during barium enema examination and to determine at what point in the examination changes are likely to occur. METHODS AND RESULTS: Blood pressure measurements were taken at seven points during the course of barium enema examination in 107 consecutive patients. We found that patients over the age of 60 years had statistically significant decreases in blood pressure when they were stood up during the course of the examination. Many of these patients were asymptomatic. Patients who had symptoms (15/107, 14%) when standing up had a degree of hypotension. The duration of barium enema examination is longer in those patients who experience symptoms. CONCLUSION: During a barium enema examination hypotension occurs at the point of standing up more frequently in patients over 60 years and in those who suffer symptoms at this time. Patients who fall into one of these groups should be considered at risk of fainting at this point in the examination. A modified technique to avoid standing should be considered in at-risk patients. Roach, S.C. et al. (2001)

  15. Blood Pressure Control: Stroke and Stroke Prevention

    Directory of Open Access Journals (Sweden)

    Hans-Christoph Diener

    2005-03-01

    Full Text Available Hypertension is the most important modifiable risk factor for primary and secondary stroke prevention.All antihypertensive drugs are effective in primary prevention: the risk reduction for stroke is 30—42%. However, not all classes of drugs have the same effects: there is some indication that angiotensin receptor blockers may be superior to other classes of antihypertensive drugs in stroke prevention.Seventy-five percent of patients who present to hospital with acute stroke have elevated blood pressure within the first 24—48 hours. Extremes of systolic blood pressure (SBP increase the risk of death or dependency. The aim of treatment should be to achieve and maintain the SBP in the range 140—160 mmHg. However, fast and drastic blood pressure lowering can have adverse consequences.The PROGRESS trial of secondary prevention with perindopril + indapamide versus placebo + placebo showed a decrease in numbers of stroke recurrences in patients given both active antihypertensive agents, more impressive for cerebral haemorrhage.There were also indications that active treatment might decrease the development of post-stroke dementia.

  16. Improvement of a sensor unit for wrist blood pressure monitoring system

    Science.gov (United States)

    Koo, Sangjun; Kwon, Jongwon; Park, Yongman; Ayuzenara, Odgerel; Kim, Hiesik

    2007-12-01

    A blood pressure sensor unit for ubiquitous healthcare monitoring was newly developed. The digital wrist band-type blood pressure devices for home are popular already in the market. It is useful for checking blood pressure level at home and control of hypertension. Especially, it is very essential home device to check the health condition of blood circulation disease. Nowadays many product types are available. But the measurement of blood pressure is not accurate enough compared with the mechanical type. It needs to be upgraded to assure the precise health data enough to use in the hospital. The structure, feature and output signal of capacitor type pressure sensors are analyzed. An improved design of capacitor sensor is suggested. It shows more precise health data after use on a wrist band type health unit. They can be applied for remote u-health medical service.

  17. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    Science.gov (United States)

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  18. Associations of ambulatory blood pressure with urinary caffeine and caffeine metabolite excretions.

    Science.gov (United States)

    Guessous, Idris; Pruijm, Menno; Ponte, Belén; Ackermann, Daniel; Ehret, Georg; Ansermot, Nicolas; Vuistiner, Philippe; Staessen, Jan; Gu, Yumei; Paccaud, Fred; Mohaupt, Markus; Vogt, Bruno; Pechère-Bertschi, Antoinette; Pechère-Berstchi, Antoinette; Martin, Pierre-Yves; Burnier, Michel; Eap, Chin B; Bochud, Murielle

    2015-03-01

    Intake of caffeinated beverages might be associated with reduced cardiovascular mortality possibly via the lowering of blood pressure. We estimated the association of ambulatory blood pressure with urinary caffeine and caffeine metabolites in a population-based sample. Families were randomly selected from the general population of Swiss cities. Ambulatory blood pressure monitoring was conducted using validated devices. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 hours urine using ultrahigh performance liquid chromatography tandem mass spectrometry. We used mixed models to explore the associations of urinary excretions with blood pressure although adjusting for major confounders. The 836 participants (48.9% men) included in this analysis had mean age of 47.8 and mean 24-hour systolic and diastolic blood pressure of 120.1 and 78.0 mm Hg. For each doubling of caffeine excretion, 24-hour and night-time systolic blood pressure decreased by 0.642 and 1.107 mm Hg (both P values theobromine excretion was not associated with blood pressure. Anti-hypertensive therapy, diabetes mellitus, and alcohol consumption modify the association of caffeine urinary excretion with systolic blood pressure. Ambulatory systolic blood pressure was inversely associated with urinary excretions of caffeine and other caffeine metabolites. Our results are compatible with a potential protective effect of caffeine on blood pressure. © 2014 American Heart Association, Inc.

  19. An affordable cuff-less blood pressure estimation solution.

    Science.gov (United States)

    Jain, Monika; Kumar, Niranjan; Deb, Sujay

    2016-08-01

    This paper presents a cuff-less hypertension pre-screening device that non-invasively monitors the Blood Pressure (BP) and Heart Rate (HR) continuously. The proposed device simultaneously records two clinically significant and highly correlated biomedical signals, viz., Electrocardiogram (ECG) and Photoplethysmogram (PPG). The device provides a common data acquisition platform that can interface with PC/laptop, Smart phone/tablet and Raspberry-pi etc. The hardware stores and processes the recorded ECG and PPG in order to extract the real-time BP and HR using kernel regression approach. The BP and HR estimation error is measured in terms of normalized mean square error, Error Standard Deviation (ESD) and Mean Absolute Error (MAE), with respect to a clinically proven digital BP monitor (OMRON HBP1300). The computed error falls under the maximum standard allowable error mentioned by Association for the Advancement of Medical Instrumentation; MAE cost home and clinic bases solution for continuous health monitoring.

  20. High blood pressure and visual sensitivity

    Science.gov (United States)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  1. A Nutritional Strategy for the Treatment of High Blood Pressure.

    Science.gov (United States)

    Podell, Richard N.

    1984-01-01

    Some physicians wonder if high blood pressure can be controlled without the use of drugs and their potential side effects. Current findings concerning nutrition and high blood pressure are presented. (RM)

  2. Get the Most Out of Home Blood Pressure Monitoring

    Science.gov (United States)

    Get the most out of home blood pressure monitoring Checking your blood pressure at home is an important part of managing ... monitors might not give you an accurate reading. Most pharmacies, medical supply stores and some websites sell ...

  3. Can Whole-Grain Foods Lower Blood Pressure?

    Science.gov (United States)

    ... eating more whole-grain foods help lower my blood pressure? Answers from Sheldon G. Sheps, M.D. It might. Eating ... might help reduce your chance of developing high blood pressure (hypertension). Whole grains are grains that include the ...

  4. Snapshot: Blood Pressure in the U.S.

    Science.gov (United States)

    ... please visit this page: About CDC.gov . Home Blood Pressure: Make Control Your Goal Infographic Recommend on Facebook ... Compartir Copy the code below to use the Blood Pressure Infographic on your web page or social media ...

  5. Sleep Deprivation: A Cause of High Blood Pressure?

    Science.gov (United States)

    ... it true that sleep deprivation can cause high blood pressure? Answers from Sheldon G. Sheps, M.D. Possibly. It's thought that ... hours a night could be linked to increased blood pressure. People who sleep five hours or less a ...

  6. Blood Pressure Medications: Can They Raise My Triglycerides?

    Science.gov (United States)

    ... medications: Can they raise my triglycerides? Can some blood pressure medications cause an increase in triglycerides? Answers from Sheldon G. Sheps, M.D. Yes, some blood pressure medications can affect triglyceride and cholesterol levels. Hydrochlorothiazide ...

  7. High blood pressure - what to ask your doctor

    Science.gov (United States)

    What to ask your doctor about high blood pressure; Hypertension - what to ask your doctor ... problems? What medicines am I taking to treat high blood pressure? Do they have any side effects? What should ...

  8. High Blood Pressure, Afib and Your Risk of Stroke

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More High Blood Pressure, AFib and Your Risk of Stroke Updated:Aug ... have a stroke for the first time have high blood pressure . And an irregular atrial heart rhythm — a condition ...

  9. Blood pressure pattern of adolescent offsprings of hypertensive ...

    African Journals Online (AJOL)

    Blood pressure pattern of adolescent offsprings of hypertensive fathers in Lagos ... in adults which emphasizes the need to track blood pressure in children. ... are hypertensive while among adolescents with normotensive parents, 11.0% for ...

  10. 21 CFR 864.6160 - Manual blood cell counting device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual blood cell counting device. 864.6160 Section 864.6160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6160 Manual...

  11. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  12. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  13. Ambulatory blood pressure monitoring (ABPM) in nonagenarians.

    Science.gov (United States)

    Formiga, Francesc; Ferrer, Assumpta; Sobrino, Javier; Coca, Antonio; Riera, Antoni; Pujol, Ramón

    2009-01-01

    The objective of the study is to investigate ambulatory blood pressure monitoring (ABPM) in a sample of Spanish nonagenarians. We also analyzed the misdiagnosis of hypertension and investigated blood pressure (BP) control in treated hypertensive nonagenarians. Twenty-four-hour ABPM was undertaken in a group of 42 nonagenarians. The 24-h mean, daytime BP, nighttime BP and heart rate (HR) were extracted from the ABPM. Sociodemographic data, the ability to perform basic daily activities, measured by the Barthel index (BI) or instrumental activities revealed by the Lawton and Brody index (LI), cognition, and comorbidity were evaluated. Thirty-one subjects were receiving antihypertensive drug treatment. Twenty-four hour, daytime and sleeping pressures averaged 130/65, 131/68 and 128/63mmHg, respectively. Seventeen (40.5%) of the 42 patients had a daytime BP of 135/85 or higher. In terms of the BP pattern, 8 (19%) subjects were dippers, 19 (45%) non-dippers, and 15 (36%) were risers. Five (45.46%) out of 11 patients with no evidence of hypertension (normotensive patients) had a daytime BP of 135/85 or higher. The mean daytime BP was 135/85 or higher in 12 (38.7%) out of 31 nonagenarians who had previously received therapy for hypertension. In, conclusion a high prevalence of hypertension, misdiagnosis and inadequate BP control was found in nonagenarians treated for hypertension.

  14. Prospective clinical study to evaluate an oscillometric blood pressure monitor in pet rabbits.

    Science.gov (United States)

    Bellini, Luca; Veladiano, Irene A; Schrank, Magdalena; Candaten, Matteo; Mollo, Antonio

    2018-02-27

    Rabbits are particularly sensitive to develop hypotension during sedation or anaesthesia. Values of systolic or mean non-invasive arterial blood pressure below 80 or 60 mmHg respectively are common under anaesthesia despite an ongoing surgery. A reliable method of monitoring arterial blood pressure is extremely important, although invasive technique is not always possible due to the anatomy and dimension of the artery. The aim of this study was to evaluate the agreement between a new oscillometric device for non-invasive arterial blood pressure measurement and the invasive method. Moreover the trending ability of the device, ability to identify changes in the same direction with the invasive methods, was evaluated as well as the sensibility of the device in identifying hypotension arbitrarily defined as invasive arterial blood pressure below 80 or 60 mmHg. Bland-Altman analysis for repeated measurements showed a poor agreement between the two methods; the oscillometric device overestimated the invasive arterial blood pressure, particularly at high arterial pressure values. The same analysis repeated considering oscillometric measurement that match invasive mean pressure lower or equal to 60 mmHg showed a decrease in biases and limits of agreement between methods. The trending ability of the device, evaluated with both the 4-quadrant plot and the polar plot was poor. Concordance rate of mean arterial blood pressure was higher than systolic and diastolic pressure although inferior to 90%. The sensibility of the device in detecting hypotension defined as systolic or mean invasive arterial blood pressure lower than 80 or 60 mmHg was superior for mean oscillometric pressure rather than systolic. A sensitivity of 92% was achieved with an oscillometric measurement for mean pressure below 65 mmHg instead of 60 mmHg. Non-invasive systolic blood pressure is less sensitive as indicator of hypotension regardless of the cutoff limit considered. Although mean invasive

  15. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    lifting and supporting weights) and have an important influence on blood pressure, it is essential to evaluate blood pressure response to iso- metric effort. This test can reveal high blood pressure that might otherwise not be detected. Only a few ...

  16. Admission Blood Pressure of Stroke Patients and Its Relationship to ...

    African Journals Online (AJOL)

    Background: High blood pressure is often said to be associated with poor outcome in stroke. However, there remains some uncertainly about the relationship of blood pressure to mortality in stroke. Objective: This study seeks to determine the influence of admission blood pressure on early mortality of stroke patients at the ...

  17. Worldwide trends in blood pressure from 1975 to 2015

    NARCIS (Netherlands)

    Ezzati, Majid; Geleijnse, J.M.

    2017-01-01

    Background

    Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic

  18. Anxiety and blood pressure prior to dental treatment.

    NARCIS (Netherlands)

    Benjamins, C.; Schuurs, A.H.; Asscheman, H.; Hoogstraten, J.

    1990-01-01

    Assessed dental anxiety and blood pressure immediately prior to a dental appointment in 24 patients attending a university dental clinic or a clinic for anxious dental patients in the Netherlands. Blood pressure was assessed by 2 independent methods, and the interchangeability of the blood-pressure

  19. A modified isometric test to evaluate blood pressure control with ...

    African Journals Online (AJOL)

    Blood pressure at rest is not predictive of roundthe- clock values. Blood pressure should therefore be measured during effort to evaluate hypertension and its response to treatment. The effect of sustained-release verapamil (240 mg taken once a day) on blood pressure at rest and during isometric effort was therefore ...

  20. Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study.

    Science.gov (United States)

    Casiglia, Edoardo; Tikhonoff, Valérie; Albertini, Federica; Palatini, Paolo

    2016-10-01

    The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, blood pressure was measured in the office and self-measured at home with an upper-arm device (the UA-767 Plus) and a wrist device (the UB-542, not provided with a position sensor). The upper-arm-wrist blood pressure difference detected in the office was used as the reference measurement. The discrepancy between office and home differences was the home measurement error. In the office, systolic blood pressure was 2.5% lower at wrist than at arm (P=0.002), whereas at home, systolic and diastolic blood pressures were higher at wrist than at arm (+5.6% and +5.4%, respectively; Pblood pressure values likely because of a poor memory and rendition of the instructions, leading to the wrong position of the wrist. © 2016 American Heart Association, Inc.

  1. Contributions of mean and shape of blood pressure distribution to worldwide trends and variations in raised blood pressure

    DEFF Research Database (Denmark)

    Overvad, Kim

    2018-01-01

    interventions to control blood pressure in the hypertensive population). Our aim was to quantify the contributions of these two phenomena to the worldwide trends in the prevalence of raised blood pressure. Methods: We pooled 1018 population-based studies with blood pressure measurements on 88.6 million......, where relevant. We used a linear mixed effect model to quantify the association between (probit-transformed) prevalence of raised blood pressure and age-group- and sex-specific mean blood pressure. We calculated the contributions of change in mean SBP and DBP, and of change in the prevalence...... participants from 1985 to 2016. We first calculated mean systolic blood pressure (SBP), mean diastolic blood pressure (DBP) and prevalence of raised blood pressure by sex and 10-year age group from 20-29 years to 70-79 years in each study, taking into account complex survey design and survey sample weights...

  2. Cerebral blood flow in normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Mamo, H.L.; Meric, P.C.; Ponsin, J.C.; Rey, A.C.; Luft, A.G.; Seylaz, J.A.

    1987-01-01

    A xenon-133 method was used to measure cerebral blood flow (CBF) before and after cerebrospinal fluid (CSF) removal in patients with normal pressure hydrocephalus (NPH). Preliminary results suggested that shunting should be performed on patients whose CBF increased after CSF removal. There was a significant increase in CBF in patients with NPH, which was confirmed by the favorable outcome of 88% of patients shunted. The majority of patients with senile and presenile dementia showed a decrease or no change in CBF after CSF removal. It is suggested that although changes in CBF and clinical symptoms of NPH may have the same cause, i.e., changes in the cerebral intraparenchymal pressure, there is no simple direct relation between these two events. The mechanism underlying the loss of autoregulation observed in NPH is also discussed

  3. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  4. [High blood pressure and physical exercise].

    Science.gov (United States)

    Sosner, P; Gremeaux, V; Bosquet, L; Herpin, D

    2014-06-01

    High blood pressure is a frequent pathology with many cardiovascular complications. As highlighted in guidelines, the therapeutic management of hypertension relies on non-pharmacological measures, which are diet and regular physical activity, but both patients and physicians are reluctant to physical activity prescription. To acquire the conviction that physical activity is beneficial, necessary and possible, we can take into account some fundamental and clinical studies, as well as the feedback of our clinical practice. Physical inactivity is a major risk factor for cardiovascular morbidity and mortality, and hypertension contributes to increase this risk. Conversely, regular practice of physical activity decreases very significantly the risk by up to 60%. The acute blood pressure changes during exercise and post-exercise hypotension differs according to the dynamic component (endurance or aerobic and/or strength exercises), but the repetition of the sessions leads to the chronic hypotensive benefit of physical activity. Moreover, physical activity prescription must take into account the assessment of global cardiovascular risk, the control of the hypertension, and the opportunities and desires of the patient in order to promote good adherence and beneficial lifestyle change. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. [Ambulatory blood pressure monitoring for hypertension diagnosis?

    Science.gov (United States)

    Gijón Conde, T; Banegas, J R

    2017-01-01

    The early and accurate diagnosis of hypertension is essential given its importance in the development of cardiovascular disease. The boundaries between normal blood pressure (BP) and hypertension are arbitrary and based on the benefits of treating exceeding those of not treating. Conventional BP measurement at the clinic only offers information of a particular time and presents multiple biases dependent on inherent variability of BP and measurement technique itself. Multiple studies have demonstrated the prognosis superiority in the development of cardiovascular disease of ambulatory blood pressure monitoring (ABPM), allows detection of white coat hypertension, avoiding overdiagnosis and overtreatment, and the detection of patients with masked hypertension who are at risk of underdetection and undertreatment. ABPM also assess nightime BP and circadian variability, providing additional prognostic value. ABPM is recognized in the diagnosis of hypertension in 2011 British NICE Guidelines, very argued at the 2013 European Society of Hypertension guidelines, and recommended in the US Preventive Services Task Force in 2015, 2016 Canadian Guidelines and the 2016 Spanish Program of Preventive Activities and Health Promotion (PAPPS). Its generalization is likely to be only a matter of time. Copyright © 2017 Sociedad Española de Hipertension-Liga Española para la Lucha de la Hipertensión Arterial (SEH-LELHA). Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  7. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  8. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    Science.gov (United States)

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  9. Prevalence of end-digit preference in recorded blood pressure by ...

    African Journals Online (AJOL)

    Objectives: When compared with the use of a mercury sphygmomanometer, the use of a validated digital blood pressure (BP) measuring device eliminates the risk of exposure to mercury. Digital devices are also associated with a lesser degree of end-digit preference (EDP). EDP refers to the occurrence of a particular end ...

  10. The clinical use of the device for flowing blood irradiation

    International Nuclear Information System (INIS)

    Arutyunov, A.S.; Karasev, A.B.; Kovalev, O.I.; Pisarevskij, A.A.; Skobennikov, A.K.; Trofimov, V.I.; Khaskel'berg, N.G.

    1988-01-01

    The indications and possibilities of using the device for flowing extracorporeal ultraviolet radiation of blood are considered. The uniformity of the radiation of blood in the proposed device provides an annular gap of the quartz dish with the partition in the shape of a spiral. It makes it possible to expose a larger part of the blood content of an organism simultaneously making use of various perfused methods of its detoxication

  11. Correlates of blood pressure in Yanomami Indians of northwestern Brazil.

    Science.gov (United States)

    Crews, D E; Mancilha-Carvalho, J J

    1993-01-01

    We determined associations of measures of body habitus with blood pressure for 100 adult Yanomami Indians (61 men, 39 women) examined during February and March 1990. Measurements included body weight and height, four skinfolds (triceps, subscapular, suprailiac, abdomen), four circumferences (wrist, upper arm, abdomen, hip), systolic and diastolic blood pressures, pulse rate, and estimated age. Various indices of fat distribution were determined from the measurements of skinfolds, circumferences, weight, and height. Estimated age averaged 35.0 years in men and 33.4 years in women (range: 15 to 63 years). Mean systolic and diastolic blood pressures were low in both men (104.8/70.4 mm Hg) and women (94.8/63.5 mm Hg), as was body mass index (men: 20.7; women: 21.4 kg/m2). In Yanomami women, all four skinfolds, wrist circumference, and the indices of hip and abdominal fat were significant correlates of systolic blood pressure, while the abdominal skinfold and wrist and hip circumferences correlated significantly with diastolic blood pressure. Among men, there was a negative correlation between estimated age and systolic blood pressure and a positive correlation between BMI and upper arm and hip circumferences and systolic blood pressure. There was a significant positive correlation between wrist, upper arm, and hip circumferences and diastolic blood pressure among Yanomami men. We used stepwise regression to generate sex-specific predictive equations for blood pressure. For men, estimated age and hip circumference, and for women, abdominal skinfold measurement and age were included in the model for systolic blood pressure. Among men, wrist circumference and height, and among women, wrist circumference alone entered the model for diastolic blood pressure. On the basis of these results, we suggest that even in a low-blood pressure, low-body fat, no-salt setting, systolic blood pressure is associated with the amount and placement of adipose tissue. However, diastolic blood

  12. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A.; van den Born, Bert-Jan H.

    2013-01-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age ( <50 or ≥60 years) and

  13. An evaluation of sharp safety blood evacuation devices.

    Science.gov (United States)

    Ford, Joanna; Phillips, Peter

    This article describes an evaluation of three sharp safety blood evacuation devices in seven Welsh NHS boards and the Welsh Blood Service. Products consisted of two phlebotomy needles possessing safety shields and one phlebotomy device with wings, tubing and a retractable needle. The device companies provided the devices and appropriate training. Participating healthcare workers used the safety device instead of the conventional device to sample blood during the evaluation period and each type of device was evaluated in random order. Participants filled in a questionnaire for each type of device and then a further questionnaire comparing the two shielded evacuation needles with each other Results showed that responses to all three products were fairly positive, although each device was not liked by everyone who used it. When the two shielded evacuation devices were compared with each other, most users preferred the device with the shield positioned directly above the needle to the device with the shield at the side. However, in laboratory tests, the preferred device produced more fluid splatter than the other shielded device on activation.

  14. 21 CFR 864.9205 - Blood and plasma warming device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood and plasma warming device. 864.9205 Section 864.9205 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  15. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    Science.gov (United States)

    Lei, Lei; Chen, Yi; Chen, Qi; Li, Yan; Wang, Ji-Guang

    2017-12-01

    The present study aimed to evaluate the accuracy of the automated oscillometric upper-arm blood pressure monitor SEJOY BP-1307 (also called JOYTECH DBP-1307) for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese individuals (13 women, 45.1 years of mean age) using a mercury sphygmomanometer (two observers) and the SEJOY BP-1307 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The average±SD of the device-observer differences was 0.2±4.1 and -1.7±4.7 mmHg for systolic and diastolic blood pressure, respectively. The SEJOY BP-1307 device achieved the criteria in both part 1 and part 2 of the validation study. The SEJOY upper-arm blood pressure monitor BP-1307 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  16. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  17. Assessing the influence of mechanical ventilation on blood gases and blood pressure in rattlesnakes

    DEFF Research Database (Denmark)

    Bertelsen, Mads Frost; Buchanan, Rasmus; Jensen, Heidi Meldgaard

    2014-01-01

    OBJECTIVE: To characterize the impact of mechanical positive pressure ventilation on heart rate (HR), arterial blood pressure, blood gases, lactate, glucose, sodium, potassium and calcium concentrations in rattlesnakes during anesthesia and the subsequent recovery period. STUDY DESIGN: Prospectiv...

  18. Self-monitoring of blood pressure during pregnancy

    DEFF Research Database (Denmark)

    Lihme, Frederikke F; Madsen, Mette E; Lykke, Jacob A

    2017-01-01

    arterial blood pressure (MAP) and were compared using the paired sample t-test. Mean values and differences of systolic and diastolic pressure were plotted in Bland-Altman plots to test the agreement of the measurements. Finally, a mean evaluation score was calculated. RESULTS: One hundred pregnant women...... and instructed each participant in correct measurement and then took three measurements on both arms. The participant then repeated the measurements and filled an evaluation questionnaire. We used a validated semiautomatic device for all measurements. Mean values were calculated for systolic, diastolic and mean...... were included in the study. Mean values of systolic, diastolic and MAP were 110.6, 69.7 and 83.3 mmHg, respectively, as assessed by the hospital staff. The corresponding self-measurements were 111.4, 70.2 and 83.9 mmHg, respectively. Mean differences between hospital and self-measurements were 0.79 mm...

  19. Association between ambient temperature and blood pressure and blood pressure regulators: 1831 hypertensive patients followed up for three years.

    Directory of Open Access Journals (Sweden)

    Qing Chen

    Full Text Available Several studies have suggested an association between ambient air temperature and blood pressure. However, this has not been reliably confirmed by longitudinal studies. Also, whether the reaction to temperature stimulation is modified by other factors such as antihypertensive medication is rarely investigated. The present study explores the relationship between ambient temperature and blood pressure, without and with antihypertensive medication, in a study of 1,831 hypertensive patients followed up for three years, in two or four weekly check ups, accumulating 62,452 follow-up records. Both baseline and follow-up blood pressure showed an inverse association with ambient temperature, which explained 32.4% and 65.6% of variation of systolic blood pressure and diastolic blood pressure (P<0.05 respectively. The amplitude of individual blood pressure fluctuation with temperature throughout a year (a 29 degrees centigrade range was 9.4/7.3 mmHg. Medication with angiotensin converting enzyme inhibitor benazepril attenuated the blood pressure fluctuation by 2.4/1.3 mmHg each year, though the inverse association of temperature and blood pressure remained. Gender, drinking behavior and body mass index were also found to modify the association between temperature and diastolic blood pressure. The results indicate that ambient temperature may negatively regulate blood pressure. Hypertensive patients should monitor and treat blood pressure more carefully in cold days, and it could be especially important for the males, thinner people and drinkers.

  20. Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.

    Science.gov (United States)

    Zeng, Wei-Fang; Liu, Ming; Kang, Yuan-Yuan; Li, Yan; Wang, Ji-Guang

    2013-08-01

    The present study aimed to evaluate the accuracy of the fully automated oscillometric upper-arm blood pressure monitor TM-2656 according to the British Hypertension Society (BHS) Protocol 1993. We recruited individuals until there were 85 eligible participants and their blood pressure could meet the blood pressure distribution requirements specified by the BHS Protocol. For each individual, we sequentially measured the systolic and diastolic blood pressures using a mercury sphygmomanometer (two observers) and the TM-2656 device (one supervisor). Data analysis was carried out according to the BHS Protocol. The device achieved grade A. The percentage of blood pressure differences within 5, 10, and 15 mmHg was 62, 85, and 96%, respectively, for systolic blood pressure, and 71, 93, and 99%, respectively, for diastolic blood pressure. The average (±SD) of the device-observer differences was -2.1±7.8 mmHg (P<0.0001) and -1.1±5.8 mmHg (P<0.0001) for systolic and diastolic blood pressures, respectively. The A&D upper-arm blood pressure monitor TM-2656 has passed the requirements of the BHS Protocol, and can thus be recommended for blood pressure measurement.

  1. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    T.D. Pystupa

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  2. Heritability of blood pressure traits and the genetic contribution to blood pressure variance explained by four blood-pressure-related genes.

    NARCIS (Netherlands)

    Rijn, M.J. van; Schut, A.F.; Aulchenko, Y.S.; Deinum, J.; Sayed-Tabatabaei, F.A.; Yazdanpanah, M.; Isaacs, A.; Axenovich, T.I.; Zorkoltseva, I.V.; Zillikens, M.C.; Pols, H.A.; Witteman, J.C.; Oostra, B.A.; Duijn, C.M. van

    2007-01-01

    OBJECTIVE: To study the heritability of four blood pressure traits and the proportion of variance explained by four blood-pressure-related genes. METHODS: All participants are members of an extended pedigree from a Dutch genetically isolated population. Heritability and genetic correlations of

  3. Development and optimization of a device for diferencial pressure measurement

    International Nuclear Information System (INIS)

    Santarine, G.A.

    1980-01-01

    The measurements of reduced values of diferencial pressure, are studied. Several situations are described where the diferencial pressure accurate measurement is necessary in routine works in the Thermohydraulic Laboratory, as well as, the major pressure measurement devices and their respective range are studied. The development of a device for diferencial pressure measurement followed by the design development of the calibration bench covering the foreseen range, start up tests realization, optimization, calibration, performance analysis and conclusions, is showed. (Author) [pt

  4. Cocoa, Blood Pressure, and Vascular Function

    Science.gov (United States)

    Ludovici, Valeria; Barthelmes, Jens; Nägele, Matthias P.; Enseleit, Frank; Ferri, Claudio; Flammer, Andreas J.; Ruschitzka, Frank; Sudano, Isabella

    2017-01-01

    Cardiovascular disease (CVD) represents the most common cause of death worldwide. The consumption of natural polyphenol-rich foods, and cocoa in particular, has been related to a reduced risk of CVD, including coronary heart disease and stroke. Intervention studies strongly suggest that cocoa exerts a beneficial impact on cardiovascular health, through the reduction of blood pressure (BP), improvement of vascular function, modulation of lipid and glucose metabolism, and reduction of platelet aggregation. These potentially beneficial effects have been shown in healthy subjects as well as in patients with risk factors (arterial hypertension, diabetes, and smoking) or established CVD (coronary heart disease or heart failure). Several potential mechanisms are supposed to be responsible for the positive effect of cocoa; among them activation of nitric oxide (NO) synthase, increased bioavailability of NO as well as antioxidant, and anti-inflammatory properties. It is the aim of this review to summarize the findings of cocoa and chocolate on BP and vascular function. PMID:28824916

  5. Cocoa, Blood Pressure, and Vascular Function

    Directory of Open Access Journals (Sweden)

    Valeria Ludovici

    2017-08-01

    Full Text Available Cardiovascular disease (CVD represents the most common cause of death worldwide. The consumption of natural polyphenol-rich foods, and cocoa in particular, has been related to a reduced risk of CVD, including coronary heart disease and stroke. Intervention studies strongly suggest that cocoa exerts a beneficial impact on cardiovascular health, through the reduction of blood pressure (BP, improvement of vascular function, modulation of lipid and glucose metabolism, and reduction of platelet aggregation. These potentially beneficial effects have been shown in healthy subjects as well as in patients with risk factors (arterial hypertension, diabetes, and smoking or established CVD (coronary heart disease or heart failure. Several potential mechanisms are supposed to be responsible for the positive effect of cocoa; among them activation of nitric oxide (NO synthase, increased bioavailability of NO as well as antioxidant, and anti-inflammatory properties. It is the aim of this review to summarize the findings of cocoa and chocolate on BP and vascular function.

  6. [Blood pressure in 6 Yanomami villages].

    Science.gov (United States)

    Mancilha-Carvalho, J J; Sousa e Silva, N A; Carvalho, J V; Lima, J A

    1991-06-01

    To investigate in Yanomami Indians that not add salt to food, the relationship between blood pressure (BP), biological variables (age, body weight, height and pulse) and urinary electrolytes (Na+, K+, Ca++ and Mg++). We studied 125 males and 129 females from six villages on Surucuru plateau and on Catrimani and Ajarani rivers region in the state of Roraima, north Brazil. Two BP measurements were made and the mean of them were used in data analysis. None hypertensive was found. Systolic BP decreased with age and correlated with body weight, pulse and urinary Na+. Diastolic BP only correlated with body weight. Height, urinary K+, Ca++ and Mg++ did not correlate with BP. There was no hypertension nor increase of BP with increasing age in these isolated Yanomami.

  7. Effects of vegetarian diets on blood pressure

    Directory of Open Access Journals (Sweden)

    Yokoyama Y

    2016-04-01

    Full Text Available Yoko Yokoyama,1,2 Kazuo Tsubota,2,3 Mitsuhiro Watanabe1,2,4,5 1Graduate School of Media and Governance, Keio University, Fujisawa, Kanagawa, 2Health Science Laboratory, 3Department of Ophthalmology, 4Department of Internal Medicine, Keio University School of Medicine, Tokyo, 5Faculty of Environment and Information Studies, Keio University, Fujisawa, Kanagawa, Japan Abstract: Hypertension is a major independent risk factor for coronary artery diseases, and the prevalence of hypertension is continuously increasing. Diet is an important factor that can be modified to prevent hypertension. According to the US Department of Health and Human Services, dietary patterns are defined as the quantities, proportions, and variety or combinations of different foods and beverages in diets and the frequency with which they are habitually consumed. In this review, the vegetarian dietary pattern is introduced with a focus on the effect on blood pressure (BP. Although the available evidence is limited, according to a previous meta-analysis of controlled trials, vegetarian dietary patterns significantly reduced systolic and diastolic BPs. One of the common features of a vegetarian diet is weight loss, which might, at least partially, explain the effect on BP. Other possible factors such as sodium, potassium, protein, amino acids, vitamin B-12, antioxidants, fiber, and the microbiome are introduced as possible mechanisms. Further studies are needed with non-Western populations to determine the most effective vegetarian dietary pattern and to explore the exact mechanisms by which these dietary patterns affect BP. Keywords: vegetarian diet, plant-based diet, blood pressure, hypertension, meta-analysis

  8. Pomegranate Consumption and Blood Pressure: A Review.

    Science.gov (United States)

    Asgary, Sedigheh; Keshvari, Mahtab; Sahebkar, Amirhossein; Sarrafzadegan, Nizal

    2017-01-01

    Pomegranate (Punica granatum L.) is a polyphenol-rich fruit with diverse medicinal properties. Several lines of experimental and clinical evidence have shown that pomegranate intake helps lowering blood pressure (BP) through different mechanisms. This study aimed to present a narrative review on the anti-hypertensive properties of different parts of pomegranate such as pomegranate juice (PJ), pomegranate peels (PP), pomegranate seed oil (PSO), pomegranate fruit extract (PFE) and the mechanisms and phytochemicals responsible for these effects. A review on the efficacy of consuming different parts of pomegranate (juice, peels, fruit extract and seed oil) in lowering BP has been performed. To find relevant studies, a search in PubMed, Science Direct and Scopus up from inception to May 4, 2015 was performed. Human, animals and in vitro studies investigating the anti-hypertensive effects of pomegranate were included in the search. Findings arising from animal and clinical studies have shown pomegranate juice can reduce BP in both short-term and long-term course. These effects are accompanied by antioxidant and anti-atherosclerotic actions that collectively improve cardiovascular health. The anti-hypertensive effects have been reported for both pomegranate juice and seed oil. Both systolic and diastolic pressures are affected. Pomegranate juice possesses antioxidant, anti-hypertensive and anti-atherosclerotic properties. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Child Abuse, Resting Blood Pressure, and Blood Pressure Reactivity to Psychosocial Stress.

    Science.gov (United States)

    Gooding, Holly C; Milliren, Carly E; Austin, S Bryn; Sheridan, Margaret A; McLaughlin, Katie A

    2016-01-01

    Childhood trauma is associated with hypertension in adults. It is unknown whether childhood trauma predicts elevated blood pressure earlier in development. We investigated whether the trauma of child abuse was associated with blood pressure in adolescents. The sample included 145 adolescents aged 13-17 years, 40% with exposure to child abuse. The mean age of participants was 14.93 years (SD = 1.33); 58% were female. The majority self-identified as non-Hispanic White (43%), with the remainder identifying as non-Hispanic Black (17%), Hispanic (17%), or other/mixed race (23%). We used established age/sex/height-specific cutoffs to determine the prevalence of prehypertension and hypertension in the sample. We used two-sample t tests to examine associations of abuse with resting systolic blood pressure (SBP) and diastolic blood pressure (DBP) and blood pressure reactivity to the Trier Social Stress Test and a frustration task. We used linear regression to adjust for potential confounders including sociodemographic variables, body mass index, smoking, and psychopathology. Mean resting SBP and DBP were 114.07 mmHg and 61.35 mmHg in those with a history of abuse and 111.39 mmHg and 56.89 mmHg in those without a history of abuse. This difference was significant for DBP only. Twelve percent of participants met criteria for prehypertension or hypertension based on resting blood pressure values; this did not differ between those with and without an abuse history. Child abuse was associated with lower DBP and SBP reactivity to laboratory stress tasks and reduced DBP reactivity to frustration. These associations were robust to adjustment for potential confounders. Child abuse is associated with higher resting DBP and blunted DBP and SBP reactivity to laboratory stress in adolescence. These findings suggest a potential pathway by which child abuse leads to hypertension. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All

  10. Accurate blood pressure recording: is it difficult?

    Science.gov (United States)

    Bhalla, A; Singh, R; D'cruz, S; Lehl, S S; Sachdev, A

    2005-11-01

    Blood pressure (BP) measurement is a routine procedure but errors are frequently committed during BP recording. AIMS AND SETTINGS: The aim of the study was to look at the prevalent practices in the institute regarding BP recording. The study was conducted in the Medicine Department at Government Medical College, Chandigarh, a teaching institute for MBBS students. A prospective, observational study was performed amongst the 80 doctors in a tertiary care hospital. All of them were observed by a single observer during the act of BP recording. The observer was well versed with the guidelines issued by British Hypertension Society (BHS) and the deviations from the standard set of guidelines issued by BHS were noted. The errors were defined as deviations from these guidelines. The results were recorded as percentage of doctors committing these errors. In our study, 90% used mercury type sphygmomanometer. Zero error of the apparatus, hand dominance was not noted by any one. Every one used the standard BP cuff for recording BP. 70% of them did not let the patient rest before recording BP. 80% did not remove the clothing from the arm. None of them recorded BP in both arms. In out patient setting, 80% recorded blood pressure in sitting position and 14% in supine position. In all the patients where BP was recorded in sitting position BP apparatus was below the level of heart and 20% did not have their arm supported. 60% did not use palpatory method for noticing systolic BP and 70% did not raise pressure 30-40 mm Hg above the systolic level before checking the BP by auscultation. 80% lowered the BP at a rate of more than 2 mm/s and 60% rounded off the BP to nearest 5-10 mm Hg. 70% recorded BP only once and 90% of the rest re inflated the cuff without completely deflating and allowing rest before a second reading was obtained. The practice of recording BP in our hospital varies from the standard guidelines issued by the BHS.

  11. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  12. Evaluation of Peripheral Blood Circulation Disorder in Scleroderma Patients Using an Optical Sensor with a Pressurization Mechanism.

    Directory of Open Access Journals (Sweden)

    Yoshiki Yamakoshi

    Full Text Available Blood circulation function of peripheral blood vessels in skin dermis was evaluated employing an optical sensor with a pressurization mechanism using the blood outflow and reflow characteristics. The device contains a light source and an optical sensor. When applied to the skin surface, it first exerts the primary pressure (higher than the systolic blood pressure, causing an outflow of blood from the dermal peripheral blood vessels. After two heartbeats, the pressure is lowered (secondary pressure and blood reflows into the peripheral blood vessels. Hemoglobin concentration, which changes during blood outflow and reflow, is derived from the received light intensity using the Beer-Lambert law. This method was evaluated in 26 healthy female volunteers and 26 female scleroderma patients. In order to evaluate the blood circulation function of the peripheral blood vessels of scleroderma patients, pressurization sequence which consists of primary pressure followed by secondary pressure was adopted. Blood reflow during the first heartbeat period after applying the secondary pressure of 40mmHg was (mean±SD 0.059±0.05%mm for scleroderma patients and 0.173±0.104%mm for healthy volunteers. Blood reflow was significantly lower in scleroderma patients than in healthy volunteers (p<0.05. This result indicates that the information necessary for assessing blood circulation disorder of peripheral blood vessels in scleroderma patients is objectively obtained by the proposed method.

  13. How to Prevent High Blood Pressure: MedlinePlus Health Topic

    Science.gov (United States)

    ... Spanish Understanding Blood Pressure Readings (American Heart Association) Weightlifting: Bad for Your Blood Pressure? (Mayo Foundation for ... High Blood Pressure High Blood Pressure in Pregnancy Nutrition Quitting Smoking Stress National Institutes of Health The ...

  14. Contributions of social context to blood pressure: findings from a multilevel analysis of social capital and systolic blood pressure.

    Science.gov (United States)

    Hamano, Tsuyoshi; Fujisawa, Yoshikazu; Yamasaki, Masayuki; Ito, Katsuhisa; Nabika, Toru; Shiwaku, Kuninori

    2011-06-01

    In recent years, few studies have quantified the effect of residential context on blood pressure. Although these studies have emphasized the importance of socioeconomic influences such as education or poverty levels, the association between the features of social structure such as social capital and blood pressure remain unclear. Therefore, we investigated whether social capital was associated with systolic blood pressure after controlling for individual potential confounders. We analyzed data from the Shimane Study conducted from 2006 to 2008 in rural mountainous regions of Japan. After excluding the missing data and data of participants taking hypertension medication, we conducted a multilevel analysis of the data for 335 individuals nested within 30 postcode sectors. Systolic blood pressure increased with increasing age and body mass index. We also found that a higher systolic blood pressure was observed among smokers and those taking medication for diabetes. Regarding the contextual effects of social capital, systolic blood pressure increased with an increasing proportion of lack of fairness, after adjustment for individual confounders. To the best of our knowledge, this study is the first to investigate the association between social capital and systolic blood pressure by using a multilevel methodological framework. Surprisingly, we found that lack of fairness had a strong effect on systolic blood pressure. However, we could not find any significant associations between other items of social capital and systolic blood pressure. Further studies are needed to clarify the mechanism by which lack of fairness may have an effect on systolic blood pressure.

  15. The effects of endurance and resistance training on blood pressure.

    Science.gov (United States)

    Schwartz, R S; Hirth, V A

    1995-10-01

    There now exists substantial clinical data supporting a blood pressure lowering effect of endurance training. Though the effect is modest (5-10 mmHg), epidemiologic studies indicate the possibility of protection against the development of hypertension and also indicate significantly reduced cardiovascular mortality and increased longevity associated with chronic endurance exercise. The data for blood pressure lowering effects of resistive training are much less compelling, and this area requires additional investigation. However, it appears that resistance training is not associated with chronic elevations in blood pressure. Future studies need to focus on: 1) the relative efficacy of low-, moderate- and high-intensity training on lowering blood pressure; 2) the effect of training on ambulatory blood pressure; 3) targeting of at risk and high responding populations; and 4) the importance of insulinemia, SNS tone and central adiposity in the mechanism of any blood pressure lowering effect of training.

  16. Announcement: National High Blood Pressure Education Month - May 2016.

    Science.gov (United States)

    2016-05-27

    May is National High Blood Pressure Education Month. High blood pressure (hypertension) is a major contributor to heart disease and stroke, two leading causes of death in the United States.* High blood pressure affects one third of U.S. adults, or approximately 75 million persons, yet approximately 11 million of these persons are not aware they have hypertension, and approximately 18 million are not being treated (unpublished data) (1,2).

  17. Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types

    OpenAIRE

    Krisnarta Sembiring; Oke Rina Ramayani; Munar Lubis

    2018-01-01

    BACKGROUND: Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. OBJECTIVE: To determine the difference in mean blood pressure among adolescents based on dyssomnia types. METHODS: a Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep...

  18. Blood pressure among the Inuit (Eskimo) populations in the Arctic

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Dewailly, Eric; Young, T Kue

    2003-01-01

    Studies of blood pressure among various Inuit (Eskimo) populations in the Arctic have given inconsistent results. Most studies reported lower blood pressure among the Inuit as compared with the predominantly white national populations. This has been attributed to traditional subsistence practices...... and lifestyle. This study compared the blood pressure among the major Inuit population groups with other populations and examined the associations with factors like age, gender, obesity and smoking....

  19. [Blood pressure variability: clinical interest or simple curiosity?].

    Science.gov (United States)

    Ciaroni, Stefano

    2007-03-14

    Blood pressure variability is a physiological phenomenon influenced by many internal and external factors. This variability could be also influenced by pathological conditions such as arterial hypertension. Two forms must be mainly distinguished: the blood pressure variability at long and short-term. The latter could only be studied by continuous recordings. In this article will be analysed the interest of measuring blood pressure variability, its cardiovascular prognosis and the therapeutic tools when it is increased.

  20. Potentiation by aminopeptidase P of blood pressure response to bradykinin.

    OpenAIRE

    Kitamura, S; Carbini, L A; Carretero, O A; Simmons, W H; Scicli, A G

    1995-01-01

    We examined whether a specific aminopeptidase P (APP) inhibitor, apstatin, increases vasodepressor responses to bradykinin in anaesthetized rats, and whether it would augment blood pressure responses further after treatment with the angiotensin-converting enzyme inhibitor (ACEi), lisinopril. Apstatin doubled the maximum blood pressure response to bradykinin. The area under the curve (AUC), which incorporates both peak blood pressure changes and duration of response, was doubled in apstatin-tr...

  1. Blood pressure normalization post-jugular venous balloon angioplasty.

    Science.gov (United States)

    Sternberg, Zohara; Grewal, Prabhjot; Cen, Steven; DeBarge-Igoe, Frances; Yu, Jinhee; Arata, Michael

    2015-05-01

    This study is the first in a series investigating the relationship between autonomic nervous system dysfunction and chronic cerebrospinal venous insufficiency in multiple sclerosis patients. We screened patients for the combined presence of the narrowing of the internal jugular veins and symptoms of autonomic nervous system dysfunction (fatigue, cognitive dysfunction, sleeping disorders, headache, thermal intolerance, bowel/bladder dysfunction) and determined systolic and diastolic blood pressure responses to balloon angioplasty. The criteria for eligibility for balloon angioplasty intervention included ≥ 50% narrowing in one or both internal jugular veins, as determined by the magnetic resonance venography, and ≥ 3 clinical symptoms of autonomic nervous system dysfunction. Blood pressure was measured at baseline and post-balloon angioplasty. Among patients who were screened, 91% were identified as having internal jugular veins narrowing (with obstructing lesions) combined with the presence of three or more symptoms of autonomic nervous system dysfunction. Balloon angioplasty reduced the average systolic and diastolic blood pressure. However, blood pressure categorization showed a biphasic response to balloon angioplasty. The procedure increased blood pressure in multiple sclerosis patients who presented with baseline blood pressure within lower limits of normal ranges (systolic ≤ 105 mmHg, diastolic ≤ 70 mmHg) but decreased blood pressure in patients with baseline blood pressure above normal ranges (systolic ≥ 130 mmHg, diastolic ≥ 80 mmHg). In addition, gender differences in baseline blood pressure subcategories were observed. The coexistence of internal jugular veins narrowing and symptoms of autonomic nervous system dysfunction suggests that the two phenomena may be related. Balloon angioplasty corrects blood pressure deviation in multiple sclerosis patients undergoing internal jugular vein dilation. Further studies should investigate the

  2. Teaming Up Against High Blood Pressure PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    Nearly one-third of American adults have high blood pressure, and more than half of them don’t have it under control. Simply seeing a doctor and taking medications isn’t enough for many people who have high blood pressure. A team-based approach by patients, health care systems, and health care providers is one of the best ways to treat uncontrolled high blood pressure.

  3. The impact of arm circumference on noninvasive oscillometric blood pressure referenced with intra-aortic blood pressure.

    Science.gov (United States)

    Shangguan, Qing; Wu, Yanqing; Xu, Jinsong; Su, Hai; Li, Juxiang; Hong, Kui; Cheng, Xiaoshu

    2015-12-01

    To investigate the influence of arm circumference (AC) on the brachial blood pressure (BP) measured with an adult cuff. This study included 208 patients (150 men, 61.0±8.0 years) for coronary angiography. Intra-aortic BP and noninvasive right brachial oscillometric BP (noninvasive BP) were measured simultaneously before coronary angiography. The noninvasive BP was measured using an electronic oscillometric device with an adult cuff (12×22 cm). The mid-ACs were measured. Thus, proper cuff-arm (≤26 cm) and small cuff (>26 cm) groups were created. The difference in intra-aortic and noninvasive BP was calculated as BPi-n. The correlation coefficients (r) between noninvasive and invasive systolic blood pressure (SBP), mean artery pressure, and diastolic blood pressure (DBP) were 0.88, 0.76, and 0.58, respectively. The SBPi-n was higher (7.9±1.6 vs. 5.2±1.1 mmHg), but the DBPi-n (3.9±1.4 vs. 6.1±1.0 mmHg, P26 cm. Among the four subgroups divided by 20-23, 24-26, 27-30, and 31-37 cm of AC, as the AC increased, the SBPi-n increased, but DBP decreased, resulting in noninvasive SBP 4.6 mmHg higher and noninvasive DBP 4.6 mmHg lower in the 31-37 cm group in comparison with the 20-23 cm group. When an adult cuff was used, the noninvasive oscillometric SBP was overestimated, but DBP was underestimated in the individuals with large arms against the intra-aortic BP.

  4. Definition of ambulatory blood pressure targets for diagnosis and treatment of hypertension in relation to clinic blood pressure: prospective cohort study.

    Science.gov (United States)

    Head, Geoffrey A; Mihailidou, Anastasia S; Duggan, Karen A; Beilin, Lawrence J; Berry, Narelle; Brown, Mark A; Bune, Alex J; Cowley, Diane; Chalmers, John P; Howe, Peter R C; Hodgson, Jonathan; Ludbrook, John; Mangoni, Arduino A; McGrath, Barry P; Nelson, Mark R; Sharman, James E; Stowasser, Michael

    2010-04-14

    Twenty-four hour ambulatory blood pressure thresholds have been defined for the diagnosis of mild hypertension but not for its treatment or for other blood pressure thresholds used in the diagnosis of moderate to severe hypertension. We aimed to derive age and sex related ambulatory blood pressure equivalents to clinic blood pressure thresholds for diagnosis and treatment of hypertension. We collated 24 hour ambulatory blood pressure data, recorded with validated devices, from 11 centres across six Australian states (n=8575). We used least product regression to assess the relation between these measurements and clinic blood pressure measured by trained staff and in a smaller cohort by doctors (n=1693). Mean age of participants was 56 years (SD 15) with mean body mass index 28.9 (5.5) and mean clinic systolic/diastolic blood pressure 142/82 mm Hg (19/12); 4626 (54%) were women. Average clinic measurements by trained staff were 6/3 mm Hg higher than daytime ambulatory blood pressure and 10/5 mm Hg higher than 24 hour blood pressure, but 9/7 mm Hg lower than clinic values measured by doctors. Daytime ambulatory equivalents derived from trained staff clinic measurements were 4/3 mm Hg less than the 140/90 mm Hg clinic threshold (lower limit of grade 1 hypertension), 2/2 mm Hg less than the 130/80 mm Hg threshold (target upper limit for patients with associated conditions), and 1/1 mm Hg less than the 125/75 mm Hg threshold. Equivalents were 1/2 mm Hg lower for women and 3/1 mm Hg lower in older people compared with the combined group. Our study provides daytime ambulatory blood pressure thresholds that are slightly lower than equivalent clinic values. Clinic blood pressure measurements taken by doctors were considerably higher than those taken by trained staff and therefore gave inappropriate estimates of ambulatory thresholds. These results provide a framework for the diagnosis and management of hypertension using ambulatory blood pressure values.

  5. Association of betaine with blood pressure in dialysis patients.

    Science.gov (United States)

    Wang, Lulu; Zhao, Mingming; Liu, Wenjin; Li, Xiurong; Chu, Hong; Bai, Youwei; Sun, Zhuxing; Gao, Chaoqing; Zheng, Lemin; Yang, Junwei

    2018-02-01

    Mechanisms underlying elevated blood pressure in dialysis patients are complex as a variety of non-traditional factors are involved. We sought to explore the association of circulating betaine, a compound widely distributed in food, with blood pressure in dialysis patients. We used baseline data of an ongoing cohort study involving patients on hemodialysis. Plasma betaine was measured by high performance liquid chromatography in 327 subjects. Blood pressure level was determined by intradialytic ambulatory blood pressure monitoring. The mean age of the patients was 52.6 ± 11.9 years, and 58.4% were male. Average interdialytic ambulatory systolic and diastolic blood pressure were 138.4 ± 22.7 mm Hg and 84.4 ± 12.5 mm Hg, respectively. Mean plasma betaine level was 37.6 μmol/L. Multiple linear regression analysis revealed significant associations of betaine with both systolic blood pressure (β = -3.66, P = .003) and diastolic blood pressure (β = -2.00, P = .004). The associations persisted even after extensive adjustment for cardiovascular covariates. Subgroup analysis revealed that the association between betaine and blood pressure was mainly limited to female patients. Our data suggest that alteration of circulating betaine possibly contributes to blood pressure regulation in these patients. ©2018 Wiley Periodicals, Inc.

  6. Risk Stratification by Ambulatory Blood Pressure Monitoring Across JNC Classes of Conventional Blood Pressure

    DEFF Research Database (Denmark)

    Brguljan-Hitij, Jana; Thijs, Lutgarde; Li, Yan

    2014-01-01

    BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (<120/<80 mm Hg), prehypertension (120-139/80-89 mm Hg), and hypertension (≥140/≥90 mm Hg). METHODS: To assess the potential differential contribution of ambulatory blood pressure (ABP) in predict......BACKGROUND: Guidelines propose classification of conventional blood pressure (CBP) into normotension (ABP......%) and of cardiovascular (-34%), cardiac (-33%), or cerebrovascular (-47%) events. Multivariable-adjusted hazard ratios (HRs) for stroke associated with 24-hour and daytime diastolic ABP (+5 mm Hg) were higher (P ≤ 0.045) in normotension than in prehypertension and hypertension (1.98 vs.1.19 vs.1.28 and 1.73 vs.1.09 vs. 1.......24, respectively) with similar trends (0.03 ≤ P ≤ 0.11) for systolic ABP (+10 mm Hg). However, HRs for fatal endpoints and cardiac events associated with ABP did not differ significantly (P ≥ 0.13) across CBP categories. Of normotensive and prehypertensive participants, 7.5% and 29.3% had masked hypertension...

  7. Influence of Baseline Diastolic Blood Pressure on Effects of Intensive Compared With Standard Blood Pressure Control.

    Science.gov (United States)

    Beddhu, Srinivasan; Chertow, Glenn M; Cheung, Alfred K; Cushman, William C; Rahman, Mahboob; Greene, Tom; Wei, Guo; Campbell, Ruth C; Conroy, Margaret; Freedman, Barry I; Haley, William; Horwitz, Edward; Kitzman, Dalane; Lash, James; Papademetriou, Vasilios; Pisoni, Roberto; Riessen, Erik; Rosendorff, Clive; Watnick, Suzanne G; Whittle, Jeffrey; Whelton, Paul K

    2018-01-09

    In individuals with a low diastolic blood pressure (DBP), the potential benefits or risks of intensive systolic blood pressure (SBP) lowering are unclear. SPRINT (Systolic Blood Pressure Intervention Trial) was a randomized controlled trial that compared the effects of intensive (target baseline DBP. Mean baseline SBP and DBP were 139.7±15.6 and 78.1±11.9 mm Hg, respectively. Regardless of the randomized treatment, baseline DBP had a U-shaped association with the hazard of the primary cardiovascular disease outcome. However, the effects of the intensive SBP intervention on the primary outcome were not influenced by baseline DBP level ( P for interaction=0.83). The primary outcome hazard ratio for intensive versus standard treatment was 0.78 (95% confidence interval, 0.57-1.07) in the lowest DBP quintile (mean baseline DBP, 61±5 mm Hg) and 0.74 (95% confidence interval, 0.61-0.90) in the upper 4 DBP quintiles (mean baseline DBP, 82±9 mm Hg), with an interaction P value of 0.78. Results were similar for all-cause death and kidney events. Low baseline DBP was associated with increased risk of cardiovascular disease events, but there was no evidence that the benefit of the intensive SBP lowering differed by baseline DBP. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01206062. © 2017 American Heart Association, Inc.

  8. Dialysate magnesium level and blood pressure.

    Science.gov (United States)

    Kyriazis, John; Kalogeropoulou, Konstantina; Bilirakis, Leonidas; Smirnioudis, Nikolaos; Pikounis, Vasilios; Stamatiadis, Dimitrios; Liolia, Ekaterini

    2004-09-01

    We investigated the way dialysate magnesium (dMg) concentrations could affect blood pressure (BP) during hemodialysis (HD). Eight HD patients underwent four midweek HD treatments consecutively, using, during each four-hour HD session, one of the following four dialysate formulations, in randomized order, which differed only with regard to dMg and dialysate calcium (dCa) concentrations (in mmol/L): 0.75 dMg, 1.75 dCa (group I); 0.25 dMg, 1.75 dCa (group II); 0.75 dMg, 1.25 dCa (group III); 0.25 dMg, 1.25 dCa (group IV). Before HD and at four 60-minute intervals during the HD sessions, BP and noninvasive measurements of cardiac index (CI) were obtained. Additionally, 14 HD patients were treated for four weeks with 0.5 mmol/L dMg, followed by four weeks with 0.25 mmol/L dMg, and another four weeks with 0.75 mmol/L dMg, in random order. In all treatments dCa was 1.25 mmol/L. BP and symptoms were recorded during each HD session. Mean arterial pressure (MAP) decreased to a significantly (P dMg was superior to the other two treatments regarding intradialytic morbidity (P dMg level to 0.75 mmol/L could prevent IDH frequently seen with the use of 1.25 mmol/L dCa. Thus, manipulating dMg levels independently or in concert with dCa levels might have important implications with regard to dialysis tolerance.

  9. Predicting Increased Blood Pressure Using Machine Learning

    Science.gov (United States)

    Golino, Hudson Fernandes; Amaral, Liliany Souza de Brito; Duarte, Stenio Fernando Pimentel; Soares, Telma de Jesus; dos Reis, Luciana Araujo

    2014-01-01

    The present study investigates the prediction of increased blood pressure by body mass index (BMI), waist (WC) and hip circumference (HC), and waist hip ratio (WHR) using a machine learning technique named classification tree. Data were collected from 400 college students (56.3% women) from 16 to 63 years old. Fifteen trees were calculated in the training group for each sex, using different numbers and combinations of predictors. The result shows that for women BMI, WC, and WHR are the combination that produces the best prediction, since it has the lowest deviance (87.42), misclassification (.19), and the higher pseudo R 2 (.43). This model presented a sensitivity of 80.86% and specificity of 81.22% in the training set and, respectively, 45.65% and 65.15% in the test sample. For men BMI, WC, HC, and WHC showed the best prediction with the lowest deviance (57.25), misclassification (.16), and the higher pseudo R 2 (.46). This model had a sensitivity of 72% and specificity of 86.25% in the training set and, respectively, 58.38% and 69.70% in the test set. Finally, the result from the classification tree analysis was compared with traditional logistic regression, indicating that the former outperformed the latter in terms of predictive power. PMID:24669313

  10. Predicting increased blood pressure using machine learning.

    Science.gov (United States)

    Golino, Hudson Fernandes; Amaral, Liliany Souza de Brito; Duarte, Stenio Fernando Pimentel; Gomes, Cristiano Mauro Assis; Soares, Telma de Jesus; Dos Reis, Luciana Araujo; Santos, Joselito

    2014-01-01

    The present study investigates the prediction of increased blood pressure by body mass index (BMI), waist (WC) and hip circumference (HC), and waist hip ratio (WHR) using a machine learning technique named classification tree. Data were collected from 400 college students (56.3% women) from 16 to 63 years old. Fifteen trees were calculated in the training group for each sex, using different numbers and combinations of predictors. The result shows that for women BMI, WC, and WHR are the combination that produces the best prediction, since it has the lowest deviance (87.42), misclassification (.19), and the higher pseudo R (2) (.43). This model presented a sensitivity of 80.86% and specificity of 81.22% in the training set and, respectively, 45.65% and 65.15% in the test sample. For men BMI, WC, HC, and WHC showed the best prediction with the lowest deviance (57.25), misclassification (.16), and the higher pseudo R (2) (.46). This model had a sensitivity of 72% and specificity of 86.25% in the training set and, respectively, 58.38% and 69.70% in the test set. Finally, the result from the classification tree analysis was compared with traditional logistic regression, indicating that the former outperformed the latter in terms of predictive power.

  11. Predicting Increased Blood Pressure Using Machine Learning

    Directory of Open Access Journals (Sweden)

    Hudson Fernandes Golino

    2014-01-01

    Full Text Available The present study investigates the prediction of increased blood pressure by body mass index (BMI, waist (WC and hip circumference (HC, and waist hip ratio (WHR using a machine learning technique named classification tree. Data were collected from 400 college students (56.3% women from 16 to 63 years old. Fifteen trees were calculated in the training group for each sex, using different numbers and combinations of predictors. The result shows that for women BMI, WC, and WHR are the combination that produces the best prediction, since it has the lowest deviance (87.42, misclassification (.19, and the higher pseudo R2 (.43. This model presented a sensitivity of 80.86% and specificity of 81.22% in the training set and, respectively, 45.65% and 65.15% in the test sample. For men BMI, WC, HC, and WHC showed the best prediction with the lowest deviance (57.25, misclassification (.16, and the higher pseudo R2 (.46. This model had a sensitivity of 72% and specificity of 86.25% in the training set and, respectively, 58.38% and 69.70% in the test set. Finally, the result from the classification tree analysis was compared with traditional logistic regression, indicating that the former outperformed the latter in terms of predictive power.

  12. Hyperuricemia and non-dipping blood pressure

    Directory of Open Access Journals (Sweden)

    Marrone O

    2013-12-01

    Full Text Available Oreste Marrone,1 Maria Rosaria Bonsignore1,21National Research Council, Institute of Biomedicine and Molecular Immunology, Palermo, Italy; 2Biomedical Department of Internal and Specialistic Medicine, University of Palermo, Palermo, ItalyThe strong association between the metabolic derangements that characterize the metabolic syndrome with arterial hypertension is very well-known, as it is the common finding of hyperuricemia in the patients with the metabolic syndrome. Besides, hyperuricemia has been found to be associated with cardiovascular, renal, and metabolic diseases; including not only gout but also type 2 diabetes mellitus, although its role as a risk factor is still debated.1 We were not aware of previous studies describing an association between uric acid levels and the non-dipping 24-hour blood pressure (BP pattern, and for that reason we were intrigued by Tutal et al’s article, regarding hypertensive patients with the metabolic syndrome.2 The authors explain some possible causes that could determine an increase in uric acid in the metabolic syndrome, and describe some pathogenetic mechanisms of systemic hypertension in their patients. We would like to point out one more possible mechanism that could link hyperuricemia to non-dipping BP.View original paper by Tutal et al

  13. Blood pressure response to low level static contractions

    DEFF Research Database (Denmark)

    Fallentin, Nils; Jørgensen, Kurt

    1992-01-01

    The present study re-examines the 15% MVC concept, i.e. the existence of a circulatory steady-state in low intensity static contractions below 15% of maximal voluntary contraction (MVC). Mean arterial blood pressure was studied during static endurance contractions of the elbow flexor and extensor...... 0.7) min for elbow extension]. Mean arterial blood pressure exhibited a continuous and progressive increase during the 10% MVC contractions indicating that the 15% MVC concept would not appear to be valid. The terminal blood pressure value recorded at the point of exhaustion in the 10% MVC elbow...... the circulation to the muscles was arrested just prior to the cessation of the contraction, blood pressure only partly recovered and remained elevated for as long as the occlusion persisted, indicating the level of pressure-raising muscle chemoreflexes. Based on blood pressure recordings obtained during...

  14. Blood Pressure Mobile Monitoring for Pregnant Woman Based Android System

    Science.gov (United States)

    Supriyanti, Retno; Erfayanto, Uji; Ramadani, Yogi; Murdyantoro, Eko; Widodo, Haris B.

    2016-01-01

    Currently, at least 18,000 women die every year in Indonesia due to pregnancy or childbirth. It means that every half hour a woman dies due to pregnancy or childbirth. As a result, every year 36,000 children became orphans. The high maternal mortality rate was put Indonesia on top in ASEAN. The main causes of maternal mortality are high-risk pregnancy. Mothers who have diseases like high blood pressure, pre-eclampsia, diabetes, hyperthyroidism, and already over 40 years old and infectious diseases such as rubella, hepatitis and HIV can be factors that lead to high-risk pregnancy. This paper will discuss the development of a blood pressure monitoring device that is suitable for pregnant women. It is based on convenience for pregnant women to get the equipment that is flexible with her presence. Results indicate that the equipment is in use daily support for pregnant women therefore, one of the causes of maternal mortality can be detected earlier.

  15. High blood pressure in acute ischemic stroke and clinical outcome.

    Science.gov (United States)

    Manabe, Yasuhiro; Kono, Syoichiro; Tanaka, Tomotaka; Narai, Hisashi; Omori, Nobuhiko

    2009-11-16

    This study aimed to evaluate the prognostic value of acute phase blood pressure in patients with acute ischemic stroke by determining whether or not it contributes to clinical outcome. We studied 515 consecutive patients admitted within the first 48 hours after the onset of ischemic strokes, employing systolic and diastolic blood pressure measurements recorded within 36 hours after admission. High blood pressure was defined when the mean of at least 2 blood pressure measurements was ≥200 mmHg systolic and/or ≥110 mmHg diastolic at 6 to 24 hours after admission or ≥180 mmHg systolic and/or ≥105 mmHg diastolic at 24 to 36 hours after admission. The high blood pressure group was found to include 16% of the patients. Age, sex, diabetes mellitus, hypercholesterolemia, atrial fibrillation, ischemic heart disease, stroke history, carotid artery stenosis, leukoaraiosis, NIH Stroke Scale (NIHSS) on admission and mortality were not significantly correlated with either the high blood pressure or non-high blood pressure group. High blood pressure on admission was significantly associated with a past history of hypertension, kidney disease, the modified Rankin Scale (mRS) on discharge and the length of stay. On logistic regression analysis, with no previous history of hypertension, diabetes mellitus, atrial fibrillation, and kidney disease were independent risk factors associated with the presence of high blood pressure [odds ratio (OR), 1.85 (95% confidence interval (CI): 1.06-3.22), 1.89 (95% CI: 1.11-3.22), and 3.31 (95% CI: 1.36-8.04), respectively]. Multi-organ injury may be presented in acute stroke patients with high blood pressure. Patients with high blood pressure had a poor functional outcome after acute ischemic stroke.

  16. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.

    Science.gov (United States)

    Wiesel, Joseph; Arbesfeld, Benjamin; Schechter, David

    2014-10-01

    Screening for atrial fibrillation (AF) by assessing the pulse is recommended in high-risk patients. Some clinical trials demonstrated that the Microlife blood pressure monitor (BPM) with AF detection is more accurate than pulse palpation. This led to a change in practice guidelines in the United Kingdom where AF screening with the Microlife device is recommended instead of pulse palpation. Many BPMs have irregular heart beat detection, but they have not been shown to detect AF reliably. Recently, one study, in a highly select population, suggested that the Omron BPM with irregular heart beat detection has a higher sensitivity for AF than the Microlife BPM. We compared the Microlife and Omron BPMs to electrocardiographic readings for AF detection in general cardiology patients. Inclusion criteria were age≥50 years without a pacemaker or defibrillator. A total of 199 subjects were enrolled, 30 with AF. Each subject had a 12-lead electrocardiography, 1 Omron BPM reading, and 3 Microlife BPM readings as per device instructions. The Omron device had a sensitivity of 30% (95% confidence interval [CI] 15.4% to 49.1%) with the sensitivity for the first Microlife reading of 97% (95% CI 81.4% to 100%) and the Microlife readings using the majority rule (AF positive if at least 2 of 3 individual readings were positive for AF) of 100% (95% CI 85.9% to 100%). Specificity for the Omron device was 97% (95% CI 92.5% to 99.2%) and for the first Microlife reading of 90% (95% CI 83.8% to 94.2%) and for the majority rule Microlife device of 92% (95% CI 86.2% to 95.7%; p<0.0001). The specificity of both devices is acceptable, but only the Microlife BPM has a sensitivity value that is high enough to be used for AF screening in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Ambulatory Blood Pressure Monitoring – Clinical Practice Recommendations

    Directory of Open Access Journals (Sweden)

    Katalin Mako

    2016-09-01

    Full Text Available Ambulatory blood pressure monitoring (ABPM became a subject of considerable scientific interest. Due to the increasing use of the ABPM in everyday clinical practice it is important that all the users have a correct knowledge on the clinical indications, the methodology of using the device including some technical issues and the interpretation of results. In the last years several guidelines and position papers have been published with recommendations for the monitoring process, reference values, for clinical practice and research. This paper represents a summary of the most important aspects related to the use of ABPM in daily practice, being a synthesis of recommendations from the recent published guidelines and position papers. This reference article presents the practical and technical issues of ABPM, the use of this method in special situations, the clinical interpretation of measured values including the presentation of different ABPM patterns, derived parameters, the prognostic significance and the limitations of this method.

  18. Is aerobic workload positively related to ambulatory blood pressure?

    DEFF Research Database (Denmark)

    Korshøj, Mette; Clays, Els; Lidegaard, Mark

    2016-01-01

    workload and ambulatory blood pressure (ABP) are lacking. The aim was to explore the relationship between objectively measured relative aerobic workload and ABP. METHODS: A total of 116 cleaners aged 18-65 years were included after informed consent was obtained. A portable device (Spacelabs 90217......) was mounted for 24-h measurements of ABP, and an Actiheart was mounted for 24-h heart rate measurements to calculate relative aerobic workload as percentage of relative heart rate reserve. A repeated-measure multi-adjusted mixed model was applied for analysis. RESULTS: A fully adjusted mixed model...... of measurements throughout the day showed significant positive relations (p ABP and 0.30 ± 0.04 mmHg (95 % CI 0.22-0.38 mmHg) in diastolic ABP. Correlations between...

  19. Blood pressure lowering effect of Tylophora hirsuta wall | Ahmad ...

    African Journals Online (AJOL)

    Crude hydromethanolic extract of Tylophora hirsuta (Th.Cr) was studied in spontaneous hypertensive Wistar rats for possible effects on high blood pressure and heart rate. In the absence of atropine, fall in arterial blood pressure was 64±7 mmHg at the dose of 100 mg/kg while in the presence of atropine, there was no effect ...

  20. Non-hemodynamic predictors of blood pressure in recreational sport ...

    African Journals Online (AJOL)

    Currently, there are evidences that regular physical activity is an efficient means to control high blood pressure. This cross-sectional study aims at identifying in subjects who exercise in non-institutional structures at Cotonou, the main factors that account for the inter-individual variations of the blood pressure. Four adiposity ...

  1. High blood pressure in older subjects with cognitive impairment.

    Science.gov (United States)

    Mossello, Enrico; Simoni, David

    2016-06-22

    High blood pressure and cognitive impairment often coexist in old age, but their pathophysiological association is complex. Several longitudinal studies have shown that high blood pressure at midlife is a risk factor for cognitive impairment and dementia, although this association is much less clear in old age. The effect of blood pressure lowering in reducing the risk of dementia is only borderline significant in clinical trials of older subjects, partly due to the insufficient follow-up time. Conversely, dementia onset is associated with a decrease of blood pressure values, probably secondary to neurodegeneration. Prognostic effect of blood pressure values in cognitively impaired older subjects is still unclear, with aggressive blood pressure lowering being potentially harmful in this patients category. Brief cognitive screening, coupled with simple motor assessment, are warranted to identify frail older subjects who need a more cautious approach to antihypertensive treatment. Values obtained with ambulatory blood pressure monitoring seem more useful than clinical ones to predict the outcome of cognitively impaired older subjects. Future studies should identify the most appropriate blood pressure targets in older subjects with cognitive impairment.

  2. What You Should Know About High Blood Pressure and Medications

    Science.gov (United States)

    ... Aortic Aneurysm More What You Should Know About High Blood Pressure and Medications Updated:Jan 18,2017 Is medication ... resources . This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  3. Relationship between blood pressure, body mass index and health ...

    African Journals Online (AJOL)

    Objective: Globally, studies have shown that the trend of overweight and obesity has increased astronomically and there is a close link between body mass index and blood pressure. This study determined the link between the body mass index (BMI), blood pressure and health promoting practices of women in rural and ...

  4. Chronic Tea Consumption Lowers Blood Pressure in Rats: Some ...

    African Journals Online (AJOL)

    Chronic Tea Consumption Lowers Blood Pressure in Rats: Some Associated Mechanisms. ... Nigerian Journal of Health and Biomedical Sciences ... In experiment 5, group 9 (kept on NF and indomethacin solution) also had similar BP as group 10 (kept on ... KEY WORDS: Blood pressure (BP), heart rate (HR), rats, tea.

  5. Prenatal air pollution exposure and newborn blood pressure

    NARCIS (Netherlands)

    van Rossem, Lenie; Rifas-Shiman, Sheryl L.; Melly, Steven J.; Kloog, Itai; Luttmann-Gibson, Heike; Zanobetti, Antonella; Coull, Brent A.; Schwartz, Joel D.; Mittleman, Murray A.; Oken, Emily; Gillman, Matthew W.; Koutrakis, Petros; Gold, Diane R.

    2015-01-01

    Background: Air pollution exposure has been associated with increased blood pressure in adults. oBjective: We examined associations of antenatal exposure to ambient air pollution with newborn systolic blood pressure (SBP). Methods: We studied 1,131 mother–infant pairs in a Boston, Massachusetts,

  6. Cardiovascular Topics Blood pressure control at a hospital day clinic ...

    African Journals Online (AJOL)

    1999-02-01

    Feb 1, 1999 ... control in a hospital day clinic population receiving cal- cium channel ... we had showed poor control of blood pressure in this hospital-based population .... Assessment of com- .... Program are obering: 19 almost half of newly treated hyper- tensives will di ... blood pressure control and quality of life. There is ...

  7. How Potassium Can Help Control High Blood Pressure

    Science.gov (United States)

    ... Aneurysm More How Potassium Can Help Control High Blood Pressure Updated:Jan 29,2018 Understanding the heart-healthy ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  8. How High Blood Pressure Can Lead to Stroke

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More How High Blood Pressure Can Lead to Stroke Updated:Jan 29,2018 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP • Know Your ...

  9. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  10. Longitudinal correlates of change in blood pressure in adolescent girls

    NARCIS (Netherlands)

    Daniels, [No Value; McMahon, RP; Obarzanek, E; Waclawiw, MA; Similo, SL; Biro, FM; Schreiber, GB; Kimm, SYS; Morrison, JA; Barton, BA

    The objective of this study was to assess the longitudinal changes in blood pressure in black and white adolescent girls and evaluate potential determinants of changes in blood pressure, including sexual maturation and body size. A total of 1213 black and 1166 white girls, ages 9 or 10 years at

  11. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  12. Effect of Hibiscus sabdariffa on Blood Pressure and Electrolyte ...

    African Journals Online (AJOL)

    Effect of Hibiscus sabdariffa on Blood Pressure and Electrolyte Profile of Mild to Moderate Hypertensive Nigerians: A Comparative Study with Hydrochlorothiazide. ... Aim: The aim of this study is to investigate the effect of HS consumption on blood pressure (BP) and electrolytes of mild to moderate hypertensive Nigerians ...

  13. Limiting the blood pressure response in young males during ...

    African Journals Online (AJOL)

    Studies have shown that resistance exercises are beneficial in the lowering of blood pressure. This is of great significance to hypertensive patients. Unfortunately the acute effect that resistance exercises have on blood pressure can be harmful. The seated single leg press was used in this study due to the availability of ...

  14. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  15. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  16. Blood pressure indices and disease severity in patients with sickle ...

    African Journals Online (AJOL)

    Background: Individuals with sickle cell anaemia (SCA) have lower systemic blood pressures compared to individuals with haemoglobin Hb AA phenotype. Objective: To evaluate blood pressure indices of individuals with SCA in steady state, in comparison with haematological and clinical markers of disease severity.

  17. Effects of aging on blood pressure variability in resting conditions

    NARCIS (Netherlands)

    Veerman, D. P.; Imholz, B. P.; Wieling, W.; Karemaker, J. M.; van Montfrans, G. A.

    1994-01-01

    The objective of this study was to determine the effect of aging on beat-to-beat blood pressure and pulse interval variability in resting conditions and to determine the effect of aging on the sympathetic and vagal influence on the cardiovascular system by power spectral analysis of blood pressure

  18. Blood pressure and heart rate adjustment following acute Frenkel's ...

    African Journals Online (AJOL)

    Background: Frenkel's ambulatory activity has been routinely employed by physiotherapists for rehabilitation of gait coordination, however, its immediate influence on blood pressure and heart rate has not been investigated. Objective: To investigate the acute effect of Frenkel's ambulatory activity on blood pressure and ...

  19. Hypertension. Age-specificity of blood-pressure-associated complications

    OpenAIRE

    Staessen, Jan A

    2014-01-01

    In an analysis of electronic health records, 1.25 million patients aged ≥30 years without diagnosed cardiovascular disease experienced 83,098 cardiovascular events during follow-up (median 5.2 years). Associations between incident cardiovascular disease and blood pressure differed for systolic and diastolic blood pressures and between the 12 cardiovascular end points examined.

  20. Blood Pressure Abnormalities in Parkinson's Disease in a Nigerian ...

    African Journals Online (AJOL)

    To compare the effect of posture on blood pressure in levodopa-treated Parkinson's disease (PD) patients with that of age-matched controls. The design is a case control study. Blood pressure was recorded manually in the seated position with Accossons® mercury sphygmomanometer in 30 consecutive patients with PD on ...

  1. High Blood Pressure and Cold Remedies: Which Are Safe?

    Science.gov (United States)

    ... counter cold remedies safe for people who have high blood pressure? Answers from Sheldon G. Sheps, M.D. Over- ... remedies aren't off-limits if you have high blood pressure, but it's important to make careful choices. Among ...

  2. Blood Pressure Management in Cardiovascular Risk Stratification. Procedure, Progression, Process.

    NARCIS (Netherlands)

    Adiyaman, A.

    2009-01-01

    In this thesis we have explored different aspects of blood pressure measurement and related it to the risk of cardiovascular disease. In the first part we showed that when the arm is positioned under heart level, for example when the arm is placed on a desk or a chair support, the blood pressure and

  3. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  4. Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET

    International Nuclear Information System (INIS)

    Boellaard, R.; Lingen, A. van; Balen, S.C.M. van; Hoving, B.G.; Lammertsma, A.A.

    2001-01-01

    The first performance tests of a new fully programmable blood sampling device for monitoring blood radioactivity during positron emission tomography (PET) are described. Blood is withdrawn through 1-mm internal diameter tubing using an infusion pump which can be operated at rates varying from 0 to 600 ml/h. Activity in blood is measured by a 6-cm-thick bismuth germanate crystal connected to a photomultiplier tube and multichannel analyser (MCA) which are positioned within 6 cm lead shielding. Positioning of the tubing is an exact and simple procedure. The minimal readout time of the MCA is 1 s. Two independent energy windows can be set. Operation of the pump and MCA is fully controlled by a PC, i.e. sampling time, interval time and pump rate can be varied at any time during the PET scan by user-defined scripts. A number of characteristics of the new system were studied, such as sensitivity, dead time, linearity, effect of background radiation and pump rate as a function of input pressure. In addition, dispersion was measured as a function of pump rate. Finally, first clinical results were compared with manual samples. The sensitivity equalled 0.7 and 0.2 cps/Bq for 511- and 1022-keV 30% energy windows, respectively, and the system dead time was 500 ns. The system remained linear within 2% with activity concentrations up to 2.5 MBq/cc. Short-term reproducibility was better than 3% for a 1-h period. Long-term reproducibility was about 5% (1SD), which was mainly caused by variation in the diameter of the tubing. If the device was positioned in such a way that maximum shielding was directed towards the patient, the effects of background radiation from the patient on the measured activity concentration for clinically relevant conditions was minimal ( -1 were observed for pump rates higher than 300 ml/h, indicating that the system dispersion is small. Clinical data showed an excellent agreement to within 3% (1SD) between the results obtained with the new system and

  5. Wearing an abdominal belt increases diastolic blood pressure.

    Science.gov (United States)

    Rafacz, W; McGill, S M

    1996-09-01

    The purpose of this study was to determine the effect of wearing an abdominal belt on blood pressure (systolic and diastolic) and heart rate during a variety of tasks. The belt was typical of the elastic type with suspenders and Velcro tabs for cinching the belt snug. The tasks performed included sitting at rest, sitting with the torso inclined forward at 45 degrees, standing with the torso inclined forward at 45 degrees (with and without holding an 11-kg weight), a trunk axial rotation task, and squat lifting. Blood pressure was monitored noninvasively with a FINAPRES blood pressure monitor. Twenty healthy men performed each task with and without the abdominal belt. Although no significant increases in mean systolic blood pressure or heart rate were found, there was a significant increase in diastolic blood pressure in all conditions. All people considering wearing an abdominal belt should also consider the risks and liability associated with the additional cardiovascular load, particularly heart attack and stroke.

  6. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  7. Cost-effectiveness of Intensive Blood Pressure Management

    DEFF Research Database (Denmark)

    Richman, Ilana B; Fairley, Michael; Jørgensen, Mads Emil

    2016-01-01

    Importance: Among high-risk patients with hypertension, targeting a systolic blood pressure of 120 mm Hg reduces cardiovascular morbidity and mortality compared with a higher target. However, intensive blood pressure management incurs additional costs from treatment and from adverse events......-effectiveness of intensive blood pressure management among 68-year-old high-risk adults with hypertension but not diabetes. We used the Systolic Blood Pressure Intervention Trial (SPRINT) to estimate treatment effects and adverse event rates. We used Centers for Disease Control and Prevention Life Tables to project age...... and accrued $155 261 in lifetime costs, while intensive management yielded 10.5 QALYs and accrued $176 584 in costs. Intensive blood pressure management cost $23 777 per QALY gained. In a sensitivity analysis, serious adverse events would need to occur at 3 times the rate observed in SPRINT and be 3 times...

  8. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  9. Blood pressure and pain sensitivity in children and adolescents.

    Science.gov (United States)

    Drouin, Sammantha; McGrath, Jennifer J

    2013-06-01

    Elevated blood pressure is associated with diminished pain sensitivity. While this finding is well established in adults, it is less clear when the relation between blood pressure and pain sensitivity emerges across the life course. Evidence suggests this phenomenon may exist during childhood. Children (N = 309; 56% boys) aged 10-15 years and their parents participated. Blood pressure readings were taken during a resting baseline. Maximum pain intensity was rated using a visual analogue scale (rated 0-10) in response to a finger prick pain induction. Parent-measured resting blood pressure was inversely associated with boys' pain ratings only. Cross-sectionally, lower pain ratings were related to higher SBP, univariately. Longitudinally, pain ratings predicted higher DBP, even after controlling for covariates. Determining when and how the relation between blood pressure and pain sensitivity emerges may elucidate the pathophysiology of hypertension. Copyright © 2013 Society for Psychophysiological Research.

  10. Portable blood extraction device integrated with biomedical monitoring system

    Science.gov (United States)

    Khumpuang, S.; Horade, M.; Fujioka, K.; Sugiyama, S.

    2006-01-01

    Painless and portable blood extraction device has been immersed in the world of miniaturization on bio-medical research particularly in manufacturing point-of-care systems. The fabrication of a blood extraction device integrated with an electrolyte-monitoring system is reported in this paper. The device has advantages in precise controlled dosage of blood extracted including the slightly damaged blood vessels and nervous system. The in-house blood diagnostic will become simple for the patients. Main components of the portable system are; the blood extraction device and electrolyte-monitoring system. The monitoring system consists of ISFET (Ion Selective Field Effect Transistor) for measuring the concentration level of minerals in blood. In this work, we measured the level of 3 ions; Na+, K+ and Cl-. The mentioned ions are frequently required the measurement since their concentration levels in the blood can indicate whether the kidney, pancreas, liver or heart is being malfunction. The fabrication of the whole system and experimentation on each ISM (Ion Sensitive Membrane) will be provided. Taking the advantages of LIGA technology, the 100 hollow microneedles fabricated by Synchrotron Radiation deep X-ray lithography through PCT (Plane-pattern to Cross-section Transfer) technique have been consisted in 5x5 mm2 area. The microneedle is 300 μm in base-diameter, 500 μm-pitch, 800 μm-height and 50 μm hole-diameter. The total size of the blood extraction device is 2x2x2 cm 3. The package is made from a plastic socket including slots for inserting microneedle array and ISFET connecting to an electrical circuit for the monitoring. Through the dimensional design for simply handling and selection of disposable material, the patients can self-evaluate the critical level of the body minerals in anywhere and anytime.

  11. Blood pressure in Afghan male immigrants to Denmark

    DEFF Research Database (Denmark)

    Asmar, Ali; Bülow, Jens; Simonsen, Lene

    2013-01-01

    PURPOSE: Immigration from a Third-World society to a Western society can be associated with higher blood pressure and salt sensitivity. We therefore tested whether immigrants from Afghanistan to Denmark compared with non-immigrant Danes exhibit a (i) higher 24-h ambulatory blood pressure (24-h ABP...... immigrants to Denmark exhibit a lower 24-h ABP than Danes. In young Afghans, PRA is less sensitive to changes in salt intake, while PNA is higher and may reflect their lower systolic blood pressure and/or arterial pulse pressure. Whether these hormonal differences can explain the lower 24-h ABP in Afghans...

  12. Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals

    Directory of Open Access Journals (Sweden)

    Rong-Chao Peng

    2015-09-01

    Full Text Available Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services.

  13. High Blood Pressure and Chronic Kidney Disease in Children: A Guide for Parents

    Science.gov (United States)

    ... Events Advocacy Donate A to Z Health Guide High Blood Pressure and Kidney Disease in Children Print Email High ... such as the heart and brain. What is high blood pressure? Blood pressure is the force of your blood ...

  14. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ishida, Kazuo.

    1990-01-01

    Discharged water after actuating control rod drives in a BWR type reactor is once discharged to a discharging header, then returned to a master control unit and, subsequently, discharged to a reactor by way of a cooling water header. The radioactive level in the discharging header and the master control unit is increased by the reactor water to increase the operator's exposure. In view of the above, a riser is disposed for connecting a hydraulic pressure control unit incorporating a directional control valve and the cooling water head. When a certain control rod is inserted, the pressurized driving water is supplied through a hydraulic pressure control unit to the control rod drives. The discharged water from the control rod drives is entered by way of the hydraulic pressure control unit into the cooling water header and then returned to the reactor by way of other hydraulic pressure control unit and the control rod drives. Thus, the reactor water is no more recycled to the master control unit to reduce the radioactive exposure. (N.H.)

  15. Origin of fluctuations in atmospheric pressure arc plasma devices

    International Nuclear Information System (INIS)

    Ghorui, S.; Das, A.K.

    2004-01-01

    Fluctuations in arc plasma devices are extremely important for any technological application in thermal plasma. The origin of such fluctuations remains unexplained. This paper presents a theory for observed fluctuations in atmospheric pressure arc plasma devices. A qualitative explanation for observed behavior on atmospheric pressure arc plasma fluctuations, reported in the literature, can be obtained from the theory. The potential of the theory is demonstrated through comparison of theoretical predictions with reported experimental observations

  16. Reactive rise in blood pressure upon cuff inflation: cuff inflation at the arm causes a greater rise in pressure than at the wrist in hypertensive patients.

    Science.gov (United States)

    Charmoy, Alexia; Würzner, Grégoire; Ruffieux, Christiane; Hasler, Christopher; Cachat, François; Waeber, Bernard; Burnier, Michel

    2007-10-01

    Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (Pblood pressure response to cuff inflation was independent of baseline blood pressure. The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

  17. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  18. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  19. Circadian blood pressure patterns and blood pressure control in patients with chronic kidney disease.

    Science.gov (United States)

    Di Daniele, Nicola; Fegatelli, Danilo Alunni; Rovella, Valentina; Castagnola, Veronica; Gabriele, Marco; Scuteri, Angelo

    2017-12-01

    Hypertension is a major risk factor for chronic kidney disease (CKD), and CKD progression is associated with suboptimal blood pressure (BP) control. Here we evaluate the impact of CKD on the attainment of BP control and the circadian BP profile in older subjects. In this observational study, we studied 547 patients referred to the hypertension clinic, of whom 224 (40.9%) had CKD. Blood pressure (BP) control and circadian BP patterns were evaluated by 24-hour ambulatory BP monitoring. Circadian BP variability was measured as the within-subject SD of BP, the percentage of measurements exceeding normal values, hypotension, and dipping status. The attainment of adequate BP control was similar in subjects with or without CKD (around 31%). Logistic regression analysis indicated that CKD was not a determinant of adequate BP control (OR 1.004; 95% CI 0.989-1.019; p = 0.58). Patients with CKD presented as twice as higher prevalence of reverse dipper (night-time peak) for systolic BP and episodes of hypotension during daytime, independently of BP control. Knowledge of the circadian pattern of BP in hypertensive subjects with CKD could inform better than attainment of BP target about risky condition for CKD progression and cognitive decline and allow a more personalized antihypertensive treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  1. Pressure and Relative Humidity Measurement Devices for Mars 2020 Rover

    Science.gov (United States)

    Hieta, M.; Genzer, M.; Nikkanen, T.; Haukka, H.; Harri, A.-M.; Polkko, J.; Rodriguez-Manfredi, J. A.

    2017-09-01

    One of the scientific payloads onboard the NASA Mars 2020 rover mission is Mars Environmental Dynamic Analyzer (MEDA): a set of environmental sensors for Mars surface weather measurements. Finnish Meteorological Institute (FMI) provides a pressure measurement device (MEDA PS) and a relative humidity measurement device (MEDA HS) for MEDA.

  2. What Physical Fitness Component Is Most Closely Associated With Adolescents' Blood Pressure?

    Science.gov (United States)

    Nunes, Heloyse E G; Alves, Carlos A S; Gonçalves, Eliane C A; Silva, Diego A S

    2017-12-01

    This study aimed to determine which of four selected physical fitness variables, would be most associated with blood pressure changes (systolic and diastolic) in a large sample of adolescents. This was a descriptive and cross-sectional, epidemiological study of 1,117 adolescents aged 14-19 years from southern Brazil. Systolic and diastolic blood pressure were measured by a digital pressure device, and the selected physical fitness variables were body composition (body mass index), flexibility (sit-and-reach test), muscle strength/resistance (manual dynamometer), and aerobic fitness (Modified Canadian Aerobic Fitness Test). Simple and multiple linear regression analyses revealed that aerobic fitness and muscle strength/resistance best explained variations in systolic blood pressure for boys (17.3% and 7.4% of variance) and girls (7.4% of variance). Aerobic fitness, body composition, and muscle strength/resistance are all important indicators of blood pressure control, but aerobic fitness was a stronger predictor of systolic blood pressure in boys and of diastolic blood pressure in both sexes.

  3. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  4. Blood pressure and sexual maturity in adolescents: the Heartfelt Study.

    Science.gov (United States)

    Cho, S D; Mueller, W H; Meininger, J C; Liehr, P; Chan, W

    2001-01-01

    This study investigates sexual maturity as a predictor of resting blood pressures independent of other known predictors, in 179 boys and 204 girls 11-16 years of age from the Heartfelt Study. The sample included youth of African (n = 140), Mexican (n = 117), and European and "other" (n = 126) backgrounds. Sexual maturity was assessed during clinical examination of three standard indicators for each sex. Systolic and diastolic blood pressures were higher in children of maturity stages IV and V, compared to stages I-III, in each gender/ethnic group (P maturity for their age group, had significantly higher systolic blood pressures (but not diastolic) than the less advanced in linear models that included height, body mass index (BMI), ethnicity, and age as co-predictors. Diastolic blood pressures were predicted by height in boys and by age and the BMI in girls. This analysis, using a very conservative approach, suggests that sexual maturity provides important and independent information on systolic blood pressure in adolescents. Further investigation of its role in 24-hr blood pressures and in blood pressures taken during physical and emotional stress, is recommended.

  5. Mean Blood Pressure Difference among Adolescents Based on Dyssomnia Types.

    Science.gov (United States)

    Sembiring, Krisnarta; Ramayani, Oke Rina; Lubis, Munar

    2018-02-15

    Dyssomnia is the most frequent sleep disturbance and associated with increased blood pressure. There has been no study determining the difference in mean blood pressure based on dyssomnia types among adolescents. To determine the difference in mean blood pressure among adolescents based on dyssomnia types. Cross-sectional study was conducted in SMP Negeri 1 Muara Batang Gadis in April 2016. Samples were students having sleep disturbance based on Sleep Disturbance Scale for Children (SDSC) questionnaire. Stature and blood pressure data were collected along with demographic data and sleep disorder questionnaire. Analyses were done with Kruskal-Wallis test and logistic regression. P - value blood pressure (DBP) was 111.1 (SD 16.46) mmHg and 70.3 (SD 11.98) mmHg respectively. Mean SDSC score was 49.7 (SD 8.96), and the most frequent dyssomnia type was disorders of initiating and maintaining sleep. Age and sex were not the risk factors of hypertension in dyssomnia. There was a significant difference in mean SBP (P = 0.006) and DBP (P = 0.022) based on dyssomnia types. Combination dyssomnia type had the highest mean blood pressure among dyssomnia types. There is a significant difference in mean blood pressure among adolescents based on dyssomnia types.

  6. Associations between bacterial infections and blood pressure in pregnancy.

    Science.gov (United States)

    Petry, Clive J; Ong, Ken K; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2017-10-01

    To test the hypothesis that bacterial infections in pregnancy are related to maternal blood pressure. Bacterial infection was assessed using antibiotic usage as a surrogate and its association with blood pressure in pregnancy tested in the Cambridge Baby Growth Study. Antibiotic usage in pregnancy was self-reported in questionnaires. Blood pressure measurements at four time points in pregnancy were collected from the hospital notes of 622 women. Using all the available blood pressure readings (adjusted for weeks gestation) antibiotic usage was associated with a higher mean arterial blood pressure across pregnancy: antibiotics used 85(84, 87)mmHg vs. no antibiotics used 83 (83, 84) mmHg (β=2.3 (0.6, 4.0) mmHg, p=9.6×10 -3 , from 621 individuals). Further analysis revealed that antibiotic usage was associated with diastolic (β=2.3 (0.6, 4.0) mmHg; p=7.0×10 -3 ) more than systolic blood pressure (β=1.4(-0.9, 3.7)mmHg; p=0.2). The effect size associated with antibiotic usage appeared to rise slightly after the first trimester. Bacterial infection in pregnancy, as assessed by self-reported antibiotic usage, is associated with small rises in blood pressure. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  7. Dark chocolate and blood pressure: a novel study from Jordan.

    Science.gov (United States)

    Al-Safi, Saafan A; Ayoub, Nehad M; Al-Doghim, Imad; Aboul-Enein, Faisal H

    2011-11-01

    The goal of this study was to assess the effect of dark chocolate intake on cardiovascular parameters like blood pressure and heart rate values in a normotensive population. This is a randomized cross-sectional study involving a total of 14,310 adults that were selected from various regions of Jordan. Well-trained pharmacy students interviewed participants in the outpatient settings. Participants reported their weekly intake of dark chocolate that has been further classified into mild (1-2 bars/week), moderate (3-4 bars/week), and high intake ( > 4 bars/week). For each participant, the systolic blood pressure (SBP), diastolic blood pressure (DBP), and heart rate were measured three times with (10-15) minute intervals in the sitting position and the resting state. The arterial blood pressure (ABP) was calculated from the measured SBP and DBP values. All measured blood pressure values were significantly decreased for participants who reported higher dark chocolate consumption. Our results showed that heart rate values were not affected by variable intake of dark chocolate. In addition, increasing dark chocolate intake was associated with a significant decrease of blood pressure values in participants irrespective of the family history of hypertension or the age of the individual. However, heart rate values were unaffected. Higher intake of dark chocolate can be associated with lower values of blood pressure, while its effect on heart rate values was not consistent.

  8. Pressure suppression device for a reactor container

    International Nuclear Information System (INIS)

    Shimizu, Toshiaki

    1982-01-01

    Purpose: To prevent damages in drain pipes or the likes upon the water level increase due to blowing of incompressible gases. Constitution: An exhaust pipe for guiding escaping steams is connected to a main steam releaf valve. The exhaust pipe is guided into pressure-suppression-chamber water through the inside of a dry-well and by way of a vent pipe, a vent header and a drain pipe or a downcomer. Since the exhaust pipe is not exposed to the water surface inside the pressure suppression chamber, even if steams blow out into the dry-well by the rapture of pipeways or the likes to rapidly increase the water level, the water surface does not hit on the exhaust pipe, whereby the damages for the exhaust pipe and support members can be prevented to improve the reliability. (Seki, T.)

  9. Increased nocturnal blood pressure in enuretic children with polyuria.

    Science.gov (United States)

    Kruse, Anne; Mahler, Birgitte; Rittig, Soren; Djurhuus, Jens Christian

    2009-10-01

    We investigated the association between nocturnal blood pressure and urine production in children with enuresis. A total of 39 consecutive children with a mean age of 9.8 years (range 6.2 to 14.9) with monosymptomatic nocturnal enuresis completed a bladder diary, including 2 weeks of basic documentation and 2 with desmopressin titration from 120 to 240 microg sublingually. Arterial blood pressure was measured every 30 minutes during 24 hours and during 4 additional nights using an ambulatory blood pressure monitor. Furthermore, 10 healthy children were recruited into the study who completed a bladder diary for 5 days while measuring arterial blood pressures with documentation of all intake and voided volumes. Patients with nocturnal polyuria had significantly higher nocturnal mean arterial pressure than patients without polyuria and controls (p polyuria than in children without polyuria. There was a significant positive correlation between average nocturnal mean arterial pressure and nocturnal urine volume in the whole study. The association between nocturnal blood pressure and urine volume, and the role of blood pressure should be investigated in a larger group of children with enuresis who have nocturnal polyuria.

  10. Prevalence of pre-high blood pressure and high blood pressure among non-overweight children and adolescents using international blood pressure references in developed regions in China.

    Science.gov (United States)

    Tian, Changwei; Xu, Shuang; Wang, Hua; Wang, Wenming; Shen, Hui

    2017-09-01

    There is a lack of data on the prevalence of pre-high blood pressure (PreHBP) and high blood pressure (HBP), based on recent international blood pressure references, in non-overweight children and adolescents. To describe the prevalence of PreHBP and HBP in non-overweight children and adolescents in developed regions of China. In total, 588 097 non-overweight children and adolescents aged 6-17 years from the National Surveys on Chinese Students' Constitution and Health in 2015 were included. The prevalence of PreHBP was 13.41% and subjects in urban areas had a higher prevalence of PreHBP (14.14%) than those in rural areas (12.92%). Subjects in regions with a high (13.56%) or moderate (13.61%) socioeconomic status showed a higher prevalence of PreHBP than those in regions with a relatively low socioeconomic status (12.76%). A similar pattern was found for the prevalence of HBP, and the prevalence of HBP was 18.25% for all participants, 20.55% for subjects in urban areas, 16.71% in rural areas, 18.76% in high socioeconomic areas, 18.62% in moderate socioeconomic areas and 16.70% in relatively low socioeconomic areas. A large proportion of non-overweight children and adolescents had elevated blood pressure and there were urban-rural and socioeconomic disparities in the prevalence of elevated blood pressure.

  11. An oxygen pressure sensor using surface acoustic wave devices

    Science.gov (United States)

    Leighty, Bradley D.; Upchurch, Billy T.; Oglesby, Donald M.

    1993-01-01

    Surface acoustic wave (SAW) piezoelectric devices are finding widespread applications in many arenas, particularly in the area of chemical sensing. We have developed an oxygen pressure sensor based on coating a SAW device with an oxygen binding agent which can be tailored to provide variable sensitivity. The coating is prepared by dissolving an oxygen binding agent in a toluene solution of a copolymer which is then sprayed onto the surface of the SAW device. Experimental data shows the feasibility of tailoring sensors to measure the partial pressure of oxygen from 2.6 to 67 KPa (20 to 500 torr). Potential applications of this technology are discussed.

  12. The effect of fish oil supplements on blood pressure.

    Science.gov (United States)

    Lofgren, R P; Wilt, T J; Nichol, K L; Crespin, L; Pluhar, R; Eckfeldt, J

    1993-01-01

    We conducted a double-blind, placebo-controlled crossover study to determine the effects of fish oil supplementation on blood pressure in middle-aged men. Subjects were randomly assigned to consume either 20 g of fish oil or safflower oil for 12 weeks and then consume the other oil for an additional 12 weeks after a 4-week washout period. We found no significant changes from the pretreatment value in systolic or diastolic blood pressure with the use of fish oil supplements. In addition, there were no significant differences in the posttreatment blood pressures comparing the fish and safflower oil phases of the study. PMID:8427339

  13. Goat Meat Does Not Cause Increased Blood Pressure

    Directory of Open Access Journals (Sweden)

    Katsunori Sunagawa

    2014-01-01

    Full Text Available While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g were evenly separated into 4 groups. The control group (CP was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan/salt group (GY was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (p<0.01 than the CP and GM groups despite the fact that their diet consumption levels were similar. The body weight of animals in the CP, GM, and GS groups was similar while the animals in the GY group were significantly smaller (p<0.01. The blood pressure in the GM group was virtually the same as the CP group throughout the course of the experiment. In contrast, while the blood pressure of the animals in the GS and GY group from 15 to 19 weeks old was the same as the CP group, their blood pressures were significantly higher (p<0.01 after 20 weeks of age. The GY group tended to have lower blood pressure than the GS group. In experiment 2, in order to clarify whether or not the increase in blood pressure in the GS group and the GY group in experiment 1 was caused by an excessive intake of salt, the effects on blood pressure of a reduction of salt in diet were investigated. When amount of salt in the diet of the GS and GY group was reduced from 4% to 0.3%, the animal

  14. Dairy consumption, systolic blood pressure, and risk of hypertension

    DEFF Research Database (Denmark)

    Ding, Ming; Huang, Tao; Bergholdt, Helle Km

    2017-01-01

    Objective To examine whether previous observed inverse associations of dairy intake with systolic blood pressure and risk of hypertension were causal.Design Mendelian randomization study using the single nucleotide polymorphism rs4988235 related to lactase persistence as an instrumental variable...... blood pressure but not risk of hypertension (odds ratio 0.98, 0.97 to 1.00; P=0.11).Conclusion The weak inverse association between dairy intake and systolic blood pressure in observational studies was not supported by a comprehensive instrumental variable analysis and systematic review of existing...

  15. Teaming Up Against High Blood Pressure PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2012-09-04

    Nearly one-third of American adults have high blood pressure, and more than half of them don’t have it under control. Simply seeing a doctor and taking medications isn’t enough for many people who have high blood pressure. A team-based approach by patients, health care systems, and health care providers is one of the best ways to treat uncontrolled high blood pressure.  Created: 9/4/2012 by Centers for Disease Control and Prevention (CDC).   Date Released: 9/4/2012.

  16. Relationship between blood lead, blood pressure, stroke, and heart attacks in middle-aged British men

    International Nuclear Information System (INIS)

    Pocock, S.J.; Shaper, A.G.; Ashby, D.; Delves, H.T.; Clayton, B.E.

    1988-01-01

    The relationship between blood lead concentration and blood pressure is examined in a survey of 7371 men aged 40 to 59 from 24 British towns. After allowance for relevant confounding variables, including town of residence and alcohol consumption, there exists a very weak but statistically significant positive association between blood lead and both systolic and diastolic blood pressure. After 6 years of follow-up, 316 of these men had major ischemic heart disease, and 66 had a stroke. After allowance for the confounding effects of cigarette smoking and town of residence there is no evidence that blood lead is a risk factor for these cardiovascular events. However, as the blood lead-blood pressure association is so weak, it is unlikely that any consequent association between lead and cardiovascular disease could be demonstrated from prospective epidemiological studies. An overview of data from this and other large epidemiological surveys provides reasonable consistent evidence on lead and blood pressure. While NHANES II data on 2254 US men indicate a slightly stronger association between blood lead and systolic blood pressure, data from two Welsh studies on over 2000 men did not show a statistically significant association. Nevertheless, such statistical association cannot be taken as establishing a causal effect of low-level lead exposure on blood pressure

  17. Physical Activity and Pattern of Blood Pressure

    African Journals Online (AJOL)

    GB

    2014-04-02

    Apr 2, 2014 ... This study investigated physical activity (PA) and pattern of blood ... values of SBP, DBP, BMI and WHR were higher among participants with low PA compared to those ..... nervous system is associated with abdominal visceral ...

  18. High Blood Pressure and Kidney Disease

    Science.gov (United States)

    ... or technician places a strip of chemically treated paper, called a dipstick, into the urine. Patches on the dipstick change color when blood or protein is present in urine. Urine albumin-to-creatinine ratio. A health care provider uses ...

  19. Fish oil affects blood pressure and the plasma lipid profile in healthy Danish infants

    DEFF Research Database (Denmark)

    Damsgaard, C.T.; Schack-Nielsen, L.; Michaelsen, K.F.

    2006-01-01

    with an oscillometric device, and blood was sampled for analysis of erythrocyte fatty acid composition and the plasma lipid profile. This paper examines the effects of the fish oil supplement, with adjustment for the effects of the milk intervention when relevant. The fish oil intervention increased erythrocyte (n-3......Animal and epidemiologic studies indicate that early nutrition has lasting effects on metabolism and cardiovascular disease risk. In adults, (n-3) long-chain PUFA (LCPUFA) from fish oils improve blood pressure, the lipid profile, and possibly cardiovascular disease mortality. This randomized trial...... is the first to investigate the effects of fish oil on blood pressure and the lipid profile in infancy. Healthy term 9-mo old infants In 83) were randomly assigned to 5 mL fish oil daily or no fish oil for 3 mo and to 2 different milk types. Before and after the intervention, blood pressure was measured...

  20. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  1. Prenatal air pollution exposure and newborn blood pressure.

    Science.gov (United States)

    van Rossem, Lenie; Rifas-Shiman, Sheryl L; Melly, Steven J; Kloog, Itai; Luttmann-Gibson, Heike; Zanobetti, Antonella; Coull, Brent A; Schwartz, Joel D; Mittleman, Murray A; Oken, Emily; Gillman, Matthew W; Koutrakis, Petros; Gold, Diane R

    2015-04-01

    Air pollution exposure has been associated with increased blood pressure in adults. We examined associations of antenatal exposure to ambient air pollution with newborn systolic blood pressure (SBP). We studied 1,131 mother-infant pairs in a Boston, Massachusetts, area pre-birth cohort. We calculated average exposures by trimester and during the 2 to 90 days before birth for temporally resolved fine particulate matter (≤ 2.5 μm; PM2.5), black carbon (BC), nitrogen oxides, nitrogen dioxide, ozone (O3), and carbon monoxide measured at stationary monitoring sites, and for spatiotemporally resolved estimates of PM2.5 and BC at the residence level. We measured SBP at a mean age of 30 ± 18 hr with an automated device. We used mixed-effects models to examine associations between air pollutant exposures and SBP, taking into account measurement circumstances; child's birth weight; mother's age, race/ethnicity, socioeconomic position, and third-trimester BP; and time trend. Estimates represent differences in SBP associated with an interquartile range (IQR) increase in each pollutant. Higher mean PM2.5 and BC exposures during the third trimester were associated with higher SBP (e.g., 1.0 mmHg; 95% CI: 0.1, 1.8 for a 0.32-μg/m3 increase in mean 90-day residential BC). In contrast, O3 was negatively associated with SBP (e.g., -2.3 mmHg; 95% CI: -4.4, -0.2 for a 13.5-ppb increase during the 90 days before birth). Exposures to PM2.5 and BC in late pregnancy were positively associated with newborn SBP, whereas O3 was negatively associated with SBP. Longitudinal follow-up will enable us to assess the implications of these findings for health during later childhood and adulthood.

  2. Blood Pressure Out of the Office: Its Time Has Finally Come.

    Science.gov (United States)

    Krakoff, Lawrence R

    2016-03-01

    The diagnosis of hypertension includes measurement of blood pressure out of the office by either 24-hour ambulatory monitoring or home blood pressure monitoring. These methods have led to recognition of "white coat hypertension" (WCH) and "masked hypertension" (MH). Research in the 1930s first demonstrated that blood pressures in the office were often far different from those out of the office, at a time when there was no effective treatment. International attention was focused on another imminent world war and a highly controversial election in the United States. Hypertension was not a priority for concern. From the 1950s onward: (i) epidemiology linked hypertension to risk of cardiovascular disease, (ii) effective and safe drugs for treatment of hypertension appeared, (iii) randomized clinical trials demonstrated that drug treatment of hypertension is highly effective for prevention of cardiovascular disease, and (iv) advances in technology led to development of small, portable devices for recording blood pressure noninvasively at home or during usual activities. Accurate measurement of blood pressure in "real life" is now necessary and feasible for appropriate diagnosis and assessment of treatment. Out-of-office blood pressure measurement is emerging as the standard of care for hypertension. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Blood pressure and control of cardiovascular risk

    OpenAIRE

    Judith A Whitworth

    2005-01-01

    Judith A WhitworthJohn Curtin School of Medical Research, Australian National University, Canberra, ACT, AustraliaAbstract: Two key early 20th century notions, the first the primacy of diastolic pressure in determining risk, and the second that hypertension is a discrete disorder, have proved to be incorrect. We now recognize the primacy of systolic pressure as a risk factor for cardiovascular disease and that hypertension is an arbitrary definition. In the early 21st century, we are moving a...

  4. Blood pressure load does not add to ambulatory blood pressure level for cardiovascular risk stratification

    DEFF Research Database (Denmark)

    Li, Yan; Thijs, Lutgarde; Boggia, José

    2014-01-01

    Experts proposed blood pressure (BP) load derived from 24-hour ambulatory BP recordings as a more accurate predictor of outcome than level, in particular in normotensive people. We analyzed 8711 subjects (mean age, 54.8 years; 47.0% women) randomly recruited from 10 populations. We expressed BP...... load as percentage (%) of systolic/diastolic readings ≥135/≥85 mm Hg and ≥120/≥70 mm Hg during day and night, respectively, or as the area under the BP curve (mm Hg×h) using the same ceiling values. During a period of 10.7 years (median), 1284 participants died and 1109 experienced a fatal or nonfatal...... cardiovascular end point. In multivariable-adjusted models, the risk of cardiovascular complications gradually increased across deciles of BP level and load (Pbased on 24-hour systolic or diastolic BP level (generalized R(2) statistic ≤0.294%; net...

  5. Intensive versus conventional blood pressure monitoring in a general practice population. The Blood Pressure Reduction in Danish General Practice trial: a randomized controlled parallel group trial

    DEFF Research Database (Denmark)

    Klarskov, Pia; Bang, Lia E; Schultz-Larsen, Peter

    2018-01-01

    To compare the effect of a conventional to an intensive blood pressure monitoring regimen on blood pressure in hypertensive patients in the general practice setting. Randomized controlled parallel group trial with 12-month follow-up. One hundred and ten general practices in all regions of Denmark....... One thousand forty-eight patients with essential hypertension. Conventional blood pressure monitoring ('usual group') continued usual ad hoc blood pressure monitoring by office blood pressure measurements, while intensive blood pressure monitoring ('intensive group') supplemented this with frequent...... a reduction of blood pressure. Clinical Trials NCT00244660....

  6. Blood Pressure Home Monitoring in Hypertensive Patients Attending ...

    African Journals Online (AJOL)

    Blood Pressure Home Monitoring in Hypertensive Patients Attending a Tertiary ... Sixty percent of the patients were aged 50 - 69 years. ... Patients with high BP readings reported that they exercise more and reduced their daily salt intake.

  7. Remote Blood Pressure Waveform Sensing Method and Apparatus

    National Research Council Canada - National Science Library

    Antonelli, Lynn T

    2008-01-01

    The invention as disclosed is a non-contact method and apparatus for continuously monitoring a physiological event in a human or animal, such as blood pressure, which involves utilizing a laser-based...

  8. Pediatric Blood Pressure and Adult Preclinical Markers of Cardiovascular Disease

    Science.gov (United States)

    Magnussen, Costan G.; Smith, Kylie J.

    2016-01-01

    A high blood pressure level in adults is considered the single most important modifiable risk factor for global disease burden, especially those of cardiovascular (CV) origin such as stroke and ischemic heart disease. Because blood pressure levels have been shown to persist from childhood to adulthood, elevations in pediatric levels have been hypothesized to lead to increased CV burden in adulthood and, as such, might provide a window in the life course where primordial and primary prevention could be focused. In the absence of substantive data directly linking childhood blood pressure levels to overt adult CV disease, this review outlines the available literature that examines the association between pediatric blood pressure and adult preclinical markers of CV disease. PMID:27168729

  9. Wearable Beat to Beat Blood Pressure Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A key component of NASA's human exploration programs is a system that monitors the health of the crew during space missions. The wearable beat-to-beat blood pressure...

  10. Blood pressure variations in Subjects with different Haemoglobin ...

    African Journals Online (AJOL)

    Dr Olaleye Samuel

    compared with the normal controls. The systolic blood pressures in control (HB AA) and SCD patients were .... especially in older patients and may predispose them to stroke and other ... autonomic responses to change in posture or vitamin C.

  11. Blood Pressure: Does It Have a Daily Pattern?

    Science.gov (United States)

    ... and night. With Sheldon G. Sheps, M.D. Kaplan NM. Ambulatory blood pressure monitoring and white coat ... www.uptodate.com/home. Accessed Feb. 12, 2015. Kaplan NM, et al. Kaplan's Clinical Hypertension. 10th ed. ...

  12. Association between blood pressure and some other cardiovascular ...

    African Journals Online (AJOL)

    JTEkanem

    2009-11-20

    Nov 20, 2009 ... changing lifestyles and nutrition transition in those regions of the world1. ... largely ignored as a public health problem in ..... education and blood pressure in adults in. Jamaica ... factors in rural and urban elderly populations ...

  13. Physical activity, body mass index and blood pressure in primary ...

    African Journals Online (AJOL)

    Institute of Child Health, University of Benin, PMB 1154, Benin City, Nigeria. Abstract. Background: Lack of physical activity contributes to overweight and obesity. ..... and treatment of high blood pressure in children and ad- olescents.

  14. Socioeconomic and modifiable predictors of blood pressure control ...

    African Journals Online (AJOL)

    these clinics are nurse led, with varying levels of doctor involvement ... Patient and clinic factors influence blood pressure control and treatment in primary care clinics ..... role in study design, data collection and analysis, decision to publish, or.

  15. Creatine kinase activity is associated with blood pressure

    NARCIS (Netherlands)

    Brewster, Lizzy M.; Mairuhu, Gideon; Bindraban, Navin R.; Koopmans, Richard P.; Clark, Joseph F.; van Montfrans, Gert A.

    2006-01-01

    BACKGROUND: We previously hypothesized that high activity of creatine kinase, the central regulatory enzyme of energy metabolism, facilitates the development of high blood pressure. Creatine kinase rapidly provides adenosine triphosphate to highly energy-demanding processes, including cardiovascular

  16. Effect of overtime work on 24-hour ambulatory blood pressure.

    Science.gov (United States)

    Hayashi, T; Kobayashi, Y; Yamaoka, K; Yano, E

    1996-10-01

    Recently, the adverse effects of long working hours on the cardiovascular systems of workers in Japan, including "Karoshi" (death from overwork), have been the focus of social concern. However, conventional methods of health checkups are often unable to detect the early signs of such adverse effects. To evaluate the influence of overtime work on the cardiovascular system, we compared 24-hour blood pressure measurements among several groups of male white-collar workers. As a result, for those with normal blood pressure and those with mild hypertension, the 24-hour average blood pressure of the overtime groups was higher than that of the control groups; for those who periodically did overtime work, the 24-hour average blood pressure and heart rate during the busy period increased. These results indicate that the burden on the cardiovascular system of white-collar workers increases with overtime work.

  17. [Design of blood-pressure parameter auto-acquisition circuit].

    Science.gov (United States)

    Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A

    2000-02-01

    This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.

  18. Relationship between children’s and parents’ blood pressure

    OpenAIRE

    Desy Aswira Nasution; Rusdidjas; Supriatmo; Rafita Ramayati; Rosmayanti Siregar

    2014-01-01

    Background A family history of hypertension is a risk factor for hypertension in children. Past studies have reported a significant relationship between elevated blood pressure in children and hypertensive parents. Objective To assess for an association between blood pressure in children and that of their parents. Methods A cross-sectional study was conducted in 90 children aged 6-18 years in Baringin Village, Panyabungan, from May to June 2010. Subjects were collected by consecutive ...

  19. Relationship between children’s and parents’ blood pressure

    OpenAIRE

    Desy Aswira Nasution; Rusdidjas Rusdidjas; Supriatmo Supriatmo; Rafita Ramayati; Oke Rina Ramayani; Rosmayanti Siregar

    2014-01-01

    Background A family history of hypertension is a risk factor for hypertension in children. Past studies have reported a significant relationship between elevated blood pressure in children and hypertensive parents. Objective To assess for an association between blood pressure in children and that of their parents. Methods A cross-sectional study was conducted in 90 children aged 6-18 years in Baringin Village, Panyabungan, from May to June 2010. Subjects were collected...

  20. Pressure Infusion Cuff and Blood Warmer during Massive Transfusion: An Experimental Study About Hemolysis and Hypothermia.

    Science.gov (United States)

    Poder, Thomas G; Pruneau, Denise; Dorval, Josée; Thibault, Louis; Fisette, Jean-François; Bédard, Suzanne K; Jacques, Annie; Beauregard, Patrice

    2016-01-01

    Blood warmers were developed to reduce the risk of hypothermia associated with the infusion of cold blood products. During massive transfusion, these devices are used with compression sleeve, which induce a major stress to red blood cells. In this setting, the combination of blood warmer and compression sleeve could generate hemolysis and harm the patient. We conducted this study to compare the impact of different pressure rates on the hemolysis of packed red blood cells and on the outlet temperature when a blood warmer set at 41.5°C is used. Pressure rates tested were 150 and 300 mmHg. Ten packed red blood cells units were provided by Héma-Québec and each unit was sequentially tested. We found no increase in hemolysis either at 150 or 300 mmHg. By cons, we found that the blood warmer was not effective at warming the red blood cells at the specified temperature. At 150 mmHg, the outlet temperature reached 37.1°C and at 300 mmHg, the temperature was 33.7°C. To use a blood warmer set at 41.5°C in conjunction with a compression sleeve at 150 or 300 mmHg does not generate hemolysis. At 300 mmHg a blood warmer set at 41.5°C does not totally avoid a risk of hypothermia.

  1. Inter-Arm Difference in Brachial Blood Pressure in the General Population of Koreans.

    Science.gov (United States)

    Song, Bo Mi; Kim, Hyeon Chang; Shim, Jee-Seon; Lee, Myung Ha; Choi, Dong Phil

    2016-05-01

    We investigated the inter-arm difference in blood pressure of the general Korean population to identify associated factors. A total of 806 participants aged 30 to 64 years without history of major cardiovascular disease were analyzed in this cross-sectional study. They participated in the Cardiovascular and Metabolic Disease Etiology Research Center cohort study that began in 2013. Brachial blood pressure was measured simultaneously for both arms using an automated oscillometric device equipped with two cuffs in seated position. After five minutes of rest, systolic blood pressure (SBP) and diastolic blood pressure (DBP) were measured three times. The average of the three measurements was used for analysis. Multivariate logistic regression models were used to identify factors associated with inter-arm differences in blood pressure. The mean inter-arm difference was 3.3 mmHg for SBP and 2.0 mmHg for DBP. Large inter-arm differences (≥10 mmHg) in SBP and in DBP were found in 3.7% and 0.9% of subjects, respectively. A large inter-arm difference in SBP was associated with mean SBP (p=0.002) and C-reactive protein (p=0.014) while a large inter-arm different in DBP was only associated with body mass index (p=0.015). Sex, age, and anti-hypertensive medication use were not associated with differences in inter-arm blood pressure. Large inter-arm difference in blood pressure is only present in a small portion of healthy Korean adults. Our findings suggest that high SBP, chronic inflammation, and obesity may be associated with larger difference in inter-arm blood pressure.

  2. The impact of arm position on the measurement of orthostatic blood pressure.

    Science.gov (United States)

    Guss, David A; Abdelnur, Diego; Hemingway, Thomas J

    2008-05-01

    Blood pressure is a standard vital sign in patients evaluated in an Emergency Department. The American Heart Association has recommended a preferred position of the arm and cuff when measuring blood pressure. There is no formal recommendation for arm position when measuring orthostatic blood pressure. The objective of this study was to assess the impact of different arm positions on the measurement of postural changes in blood pressure. This was a prospective, unblinded, convenience study involving Emergency Department patients with complaints unrelated to cardiovascular instability. Repeated blood pressure measurements were obtained using an automatic non-invasive device with each subject in a supine and standing position and with the arm parallel and perpendicular to the torso. Orthostatic hypotension was defined as a difference of >or= 20 mm Hg systolic or >or= 10 mm Hg diastolic when subtracting standing from supine measurements. There were four comparisons made: group W, arm perpendicular supine and standing; group X, arm parallel supine and standing; group Y, arm parallel supine and perpendicular standing; and group Z, arm perpendicular supine and parallel standing. There were 100 patients enrolled, 55 men, mean age 44 years. Four blood pressure measurements were obtained on each patient. The percentage of patients meeting orthostatic hypotension criteria in each group was: W systolic 6% (95% CI 1%, 11%), diastolic 4% (95% CI 0%, 8%), X systolic 8% (95% CI 3%, 13%), diastolic 9% (95% CI 3%, 13%), Y systolic 19% (95% CI 11%, 27%), diastolic 30% (95% CI 21%, 39%), Z systolic 2% (95% CI 0%, 5%), diastolic 2% (95% CI 0%, 5%). Comparison of Group Y vs. X, Z, and W was statistically significant (p postural changes in blood pressure. The combination of the arm parallel when supine and perpendicular when standing may significantly overestimate the orthostatic change. Arm position should be held constant in supine and standing positions when assessing for orthostatic

  3. [How does salt intake influence blood pressure? Associated aetiopathogenic mechanisms].

    Science.gov (United States)

    Fernández-Llama, P; Calero, F

    2017-12-15

    Abundant evidence from epidemiological and experimental studies has established a link between salt and blood pressure. However, there is heterogeneity in the blood pressure responses of humans to changes in sodium intake. Those individuals in whom a severe, abrupt change in salt intake causes the least change in arterial pressure and are termed salt-resistant, whereas in those in whom this leads to large changes in blood pressure, are called salt sensitive. Classically, Guyton's theory of the pressure-natriuresis phenomenon has been accepted to explain the pressor effect of salt, as well as the fundamental role played by the different protein sodium transporters of the renal tubules. In recent years, new theories have emerged pointing to the possible role of the immune system and the existence of a third sodium store in the body as aetiopathogenic factors. Copyright © 2017 SEH-LELHA. Publicado por Elsevier España, S.L.U. All rights reserved.

  4. Lack of association between systolic blood pressure and blood viscosity in normotensive healthy subjects.

    Science.gov (United States)

    Irace, Concetta; Carallo, Claudio; Scavelli, Faustina; Loprete, Antonio; Merante, Valentina; Gnasso, Agostino

    2012-01-01

    A direct relationship between blood pressure and viscosity has frequently been reported, although clear data are not available. To better understand the relationship between these two variables, we evaluated blood viscosity and blood pressure in a group of healthy subjects without cardiovascular risk factors. Healthy subjects were selected from participants in a campaign of prevention of cardiovascular disease (n = 103). They underwent blood sampling for measurement of plasma and blood viscosity, haematocrit, blood lipids and glucose. The quantity and distribution of body fat was assessed by body mass index and waist/hip ratio, respectively. Systolic blood pressure (SBP) correlated significantly with age (r = 0.222) and waist/hip ratio (r = 0.374). Diastolic blood pressure (DBP) correlated significantly with waist/hip ratio (r = 0.216), haematocrit (r = 0.333) and blood viscosity (r = 0.258). Multiple linear regression analyses demonstrated that the only variable significantly associated with SBP was age, while haematocrit was the only variable significantly associated with DBP. Blood viscosity was closely related to waist/hip ratio. These findings show that SBP, in healthy subjects, is not influenced by haematocrit and blood viscosity. In contrast, DBP is related to the values of haematocrit. Among classical cardiovascular risk factors, waist/hip ratio is closely related to blood viscosity.

  5. Pressure suppression device for nuclear reactor building

    International Nuclear Information System (INIS)

    Ikegame, Noboru.

    1992-01-01

    In a nuclear reactor building, there are disposed cooling coils connected to an air supply duct at the outside of the building, an air supply blower, an air supply duct having the top end opened, an exhaustion duct having the top end opened and a bypassing pipeline interposed between the exhaustion duct and the air supply duct on the side of the inlet of the cooling coils. In the reactor building, when a radioactive material leakage accident should occur, an isolation valve is closed to isolate the building from the outside. Further, bypassing isolation valve is opened to form a closed cooling circuit by the cooling coils, the air supply blower and the air supply duct, the exhaustion duct and the bypassing pipeline in the reactor building. With such a constitution, since air as the atmosphere in the building is circulated through the closed cooling circuit and cooled by the cooling coils, the temperature is not elevated. Accordingly, since the pressure elevation of the atmosphere in the building is suppressed, the atmosphere containing radioactive materials do not flow out of the building. (I.N.)

  6. Can hibiscus tea lower blood pressure

    Science.gov (United States)

    Hibiscus sabdariffa is a common ingredient found in blended herbal teas, and beverages made from the dried calyces of this plant are popular worldwide. In vitro studies have shown that H. sabdariffa has antioxidant properties and, in animal models of hypertension, extracts of this plant lower blood ...

  7. Association between parity and breastfeeding with maternal high blood pressure.

    Science.gov (United States)

    Lupton, Samantha J; Chiu, Christine L; Lujic, Sanja; Hennessy, Annemarie; Lind, Joanne M

    2013-06-01

    The objective of this study was to determine how parity and breastfeeding were associated with maternal high blood pressure, and how age modifies this association. Baseline data for 74,785 women were sourced from the 45 and Up Study, Australia. These women were 45 years of age or older, had an intact uterus, and had not been diagnosed with high blood pressure before pregnancy. Odds ratios (ORs) and 99% confidence intervals (CIs) for the association between giving birth, breastfeeding, lifetime breastfeeding duration, and average breastfeeding per child with high blood pressure were estimated using logistic regression. The combination of parity and breastfeeding was associated with lower odds of having high blood pressure (adjusted OR, 0.89; 99% CI, 0.82-0.97; P high blood pressure when compared with parous women who never breastfed. The odds were lower with longer breastfeeding durations and were no longer significant in the majority of women over the age of 64 years. Women should be encouraged to breastfeed for as long as possible and a woman's breastfeeding history should be taken into account when assessing her likelihood of high blood pressure in later life. Copyright © 2013 Mosby, Inc. All rights reserved.

  8. Quantitative and qualitative retinal microvascular characteristics and blood pressure.

    Science.gov (United States)

    Cheung, Carol Y; Tay, Wan T; Mitchell, Paul; Wang, Jie J; Hsu, Wynne; Lee, Mong L; Lau, Qiangfeng P; Zhu, Ai L; Klein, Ronald; Saw, Seang M; Wong, Tien Y

    2011-07-01

    The present study examined the effects of blood pressure on a spectrum of quantitative and qualitative retinal microvascular signs. Retinal photographs from the Singapore Malay Eye Study, a population-based cross-sectional study of 3280 (78.7% response) persons aged 40-80 years, were analyzed. Quantitative changes in the retinal vasculature (branching angle, vascular tortuosity, fractal dimension, and vascular caliber) were measured using a semi-automated computer-based program. Qualitative signs, including focal arteriolar narrowing (FAN), arteriovenous nicking (AVN), opacification of the arteriolar wall (OAW), and retinopathy (e.g., microaneurysms, retinal hemorrhages), were assessed from photographs by trained technicians. After excluding persons with diabetes and ungradable photographs, 1913 persons provided data for this analysis. In multivariable linear regression models controlling for age, sex, BMI, use of antihypertensive medication, and other factors, retinal arteriolar branching asymmetry ratio, arteriolar tortuosity, venular tortuosity, fractal dimension, arteriolar caliber, venular caliber, FAN, AVN, and retinopathy were independently associated with mean arterial blood pressure. In contrast, arteriolar/venular branching angle, venular branching asymmetry ratio and OAW were not related to blood pressure. Retinal arteriolar caliber (sβ = -0.277) and FAN (sβ = 0.170) had the strongest associations with mean arterial blood pressure, and higher blood pressure levels were associated with increasing number of both quantitative and qualitative retinal vascular signs (P trend qualitative retinal vascular signs, with the number of signs increasing with higher blood pressure levels.

  9. Potential benefits of exercise on blood pressure and vascular function.

    Science.gov (United States)

    Pal, Sebely; Radavelli-Bagatini, Simone; Ho, Suleen

    2013-01-01

    Physical activity seems to enhance cardiovascular fitness during the course of the lifecycle, improve blood pressure, and is associated with decreased prevalence of hypertension and coronary heart disease. It may also delay or prevent age-related increases in arterial stiffness. It is unclear if specific exercise types (aerobic, resistance, or combination) have a better effect on blood pressure and vascular function. This review was written based on previous original articles, systematic reviews, and meta-analyses indexed on PubMed from years 1975 to 2012 to identify studies on different types of exercise and the associations or effects on blood pressure and vascular function. In summary, aerobic exercise (30 to 40 minutes of training at 60% to 85% of predicted maximal heart rate, most days of the week) appears to significantly improve blood pressure and reduce augmentation index. Resistance training (three to four sets of eight to 12 repetitions at 10 repetition maximum, 3 days a week) appears to significantly improve blood pressure, whereas combination exercise training (15 minutes of aerobic and 15 minutes of resistance, 5 days a week) is beneficial to vascular function, but at a lower scale. Aerobic exercise seems to better benefit blood pressure and vascular function. Copyright © 2013 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  10. Salt, Blood Pressure and Cardiovascular Changes in Human and ...

    African Journals Online (AJOL)

    Salt, Blood Pressure and Cardiovascular Changes in Human and Experimental Studies – A Review. ... Some of the pathophysiological changes include cardiac hypertrophy and enhanced cardiac contractility, enhanced contraction of blood vessels and veins in response to constrictor agonists and diminished relaxation of ...

  11. [Brief overview of the guidelines for the use of 24 hour ambulatory blood pressure monitoring (ABPM)].

    Science.gov (United States)

    Shimada, Kazuyuki

    2014-08-01

    The guidelines for the use of ambulatory blood pressure monitoring published from Japanese Circulation Society in 2010 was briefly overviewed. The accuracy of devices now used in clinical practice in Japan is of sufficient grade. The thresholds for hypertension diagnosis based on ABPM have been determined with international concensus. The evaluation of ABPM data and the clinical indications for ABPM are suggested. Particularly, white-coat hypertension, masked hypertension, nocturnal hypertension, morning hypertension and diurnal blood pressure variation are conditions for which ABPM is very useful for the detection, treatment decision and follow-up. Hypertension treatment would be very much improved by the introduction of ABPM into clinical practice.

  12. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  13. RETRACTED: Six different hemofiltration devices for blood conservation in cardiac surgery.

    Science.gov (United States)

    Boldt, J; Zickmann, B; Fedderson, B; Herold, C; Dapper, F; Hempelmann, G

    1991-05-01

    Hemofiltration devices and the Cell Saver are the most often used techniques to reduce homologous blood requirements in cardiac surgery. In a controlled, randomized study, 105 patients underwent elective aortocoronary bypass grafting. Six different hemofilters (HF-80, HFT 14, CPB 7000, Cobe 1200, UF-205, BC-140) were tested and compared with the Cell Saver (Cell Saver 4) for blood concentration during and after cardiopulmonary bypass. Efficacy, practicality, and laboratory indices including coagulation variables were documented through the morning of the first postoperative day. The HF-80 and UF-205 were the most effective devices for blood concentration. At the end of the operation, the number of platelets was least reduced in these two groups (HF-80, -7%; UF-205, -6%). Moreover, both devices had a significantly higher filtration rate than the other hemofilters. Use of the Cell Saver resulted in the lowest values in coagulation variables (AT-III, fibrinogen, number of platelets) and the most pronounced deterioration in protein homeostasis (colloid osmotic pressure, albumin). In this group, the AT-III concentration was reduced until the morning of the first postoperative day. No negative effects were seen in regard to hemofiltration (free hemoglobin and polymorphonuclear elastase; the Cell Saver group had similar values for these variables). We conclude that blood salvage with hemofiltration devices is superior to that with the Cell Saver. There were, however, significant differences among the hemofilters. The HF-80 and UF-205 were the most effective devices in this study.

  14. Continuous positive airway pressure: Physiology and comparison of devices.

    Science.gov (United States)

    Gupta, Samir; Donn, Steven M

    2016-06-01

    Nasal continuous positive airway pressure (CPAP) is increasingly used for respiratory support in preterm babies at birth and after extubation from mechanical ventilation. Various CPAP devices are available for use that can be broadly grouped into continuous flow and variable flow. There are potential physiologic differences between these CPAP systems and the choice of a CPAP device is too often guided by individual expertise and experience rather than by evidence. When interpreting the evidence clinicians should take into account the pressure generation sources, nasal interface, and the factors affecting the delivery of pressure, such as mouth position and respiratory drive. With increasing use of these devices, better monitoring techniques are required to assess the efficacy and early recognition of babies who are failing and in need of escalated support. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Red Wine Polyphenols Do Not Lower Peripheral or Central Blood Pressure in High Normal Blood Pressure and Hypertension

    NARCIS (Netherlands)

    Botden, Ilse P. G.; Draijer, Richard; Westerhof, Berend E.; Rutten, Joost H. W.; Langendonk, Janneke G.; Sijbrands, Eric J. G.; Danser, A. H. Jan; Zock, Peter L.; van den Meiracker, Anton H.

    2012-01-01

    BACKGROUND Epidemiological data suggest that modest red wine consumption may reduce cardiovascular disease risk. Red wine polyphenols improved human endothelial vascular function and reduced blood pressure (BP) in animal studies, but the results of human intervention studies investigating the effect

  16. Aortic and peripheral blood pressure during isometric and dynamic exercise

    NARCIS (Netherlands)

    Blum, V.; Carrière, E.G.J.; Kolsters, W.; Mosterd, W.L.; Schiereck, P.; Wesseling, K.H.

    1997-01-01

    The purpose of this study was to compare aortic blood pressure (AOR) to peripheral measurements by the Riva-Rocci/Korotkov (RRK) and Finapres continuous finger pressure (FIN) methods during dynamic and static exercise. A tip manometer was introduced in the ascending aorta after coronary angiography

  17. Improvement of Diurnal Blood Pressure Variation by Azilsartan.

    Science.gov (United States)

    Okamura, Keisuke; Shirai, Kazuyuki; Okuda, Tetsu; Urata, Hidenori

    2018-01-01

    Azilsartan is an angiotensin II receptor blocker with a potent antihypertensive effect. In a multicenter, prospective, open-label study, 265 patients with poor blood pressure control despite treatment with other angiotensin II receptor blockers were switched to 20 mg/day of azilsartan (patients on standard dosages) or 40 mg/day of azilsartan (patients on high dosages). Blood pressure was 149/83 mm Hg before switching and was significantly reduced from 1 month after switching until final assessment (132/76 mm Hg, P < 0.001). The pulse rate was 72/min before switching and increased significantly from 3 months after switching until final assessment (74/min, P < 0.005). A significant decrease of home morning systolic and diastolic pressure was observed from 1 and 3 months, respectively. Home morning blood pressure was 143/82 mm Hg before switching and 130/76 mm Hg at final assessment (P < 0.01). The morning-evening difference of systolic blood pressure decreased from 14.6 to 6.6 mm Hg after switching (P = 0.09). The estimated glomerular filtration rate was significantly decreased at 3, 6, and 12 months after switching, and serum uric acid was significantly increased at 12 months. No serious adverse events occurred. Azilsartan significantly reduced the blood pressure and decreased diurnal variation in patients responding poorly to other angiotensin II receptor blockers.

  18. Device for the burst protection of nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Daublebsky, P.

    1976-01-01

    The burst protection device has a hood over top and bottom of the pressure vessel with superimposed hinged supports lying in their turn against supporting rings which are connected with each other by vertical bracing. It is proposed to place an intermediate layer between hoods and vertical bracing absorbing thermal stresses, i.e. deforming plastically with gradually increasing pressure, but behaving like a rigid body in the case of shock loads. As a material lead e.g. is proposed. (UWI) [de

  19. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  20. Blood pressure standards for Saudi children and adolescents

    International Nuclear Information System (INIS)

    AlSalloum, Abdullah A.; El Mouzan, Mohammad I.; AlHerbish, Abdullah S.; AlOmar, Ahmad A.; Qurashi, Mansour M.

    2009-01-01

    Blood pressure levels may vary in children because of genetic, ethnic and socioeconomic factors. To date, there have been no large national studies in Saudi Arabia on blood pressure in children. Therefore, we sought to establish representative blood pressure reference centiles for Saudi Arabian children and adolescents. We selected a sample of children and adolescents aged from birth to 18 years by multi-stage probability sampling of the Saudi population. The selected sample represented Saudi children from the whole country. Data were collected through a house-to-house survey of all selected households in all 13 regions in the country. Data were analyzed to study the distribution pattern of systolic (SBP) and diastolic blood pressure (DBP) and to develop reference values. The 90th percentile of SBP and DBP values for each age were compared with values from a Turkish and an American study. A total of 16 226 Saudi children and adolescents from birth to 18 years were studied. Blood pressure rose steadily with age in both boys and girls. The average annual increase in SBP was 1.66 mm Hg for boys and1.44 mm Hg for girls. The average annual increase in DBP was 0.83 mm Hg for boys and 0.77 mm Hg for girls. DBP rose sharply in boys at the age of 18 years. Values for the 90th percentile of both SBP and DBP varied in Saudi children from their Turkish and American counterparts for all age groups. Blood pressure values in this study differed from those from other studies in developing countries and in the United States, indicating that comparison across studies is difficult and from that every population should use their own normal standards to define measured blood pressure levels in children. (author)

  1. Blood pressure associates with standing balance in elderly outpatients.

    Directory of Open Access Journals (Sweden)

    Jantsje H Pasma

    Full Text Available OBJECTIVES: Assessment of the association of blood pressure measurements in supine and standing position after a postural change, as a proxy for blood pressure regulation, with standing balance in a clinically relevant cohort of elderly, is of special interest as blood pressure may be important to identify patients at risk of having impaired standing balance in routine geriatric assessment. MATERIALS AND METHODS: In a cross-sectional cohort study, 197 community-dwelling elderly referred to a geriatric outpatient clinic of a middle-sized teaching hospital were included. Blood pressure was measured intermittently (n = 197 and continuously (subsample, n = 58 before and after a controlled postural change from supine to standing position. The ability to maintain standing balance was assessed during ten seconds of side-by-side, semi-tandem and tandem stance, with both eyes open and eyes closed. Self-reported impaired standing balance and history of falls were recorded by questionnaires. Logistic regression analyses were used to examine the association between blood pressure and 1 the ability to maintain standing balance; 2 self-reported impaired standing balance; and 3 history of falls, adjusted for age and sex. RESULTS: Blood pressure decrease after postural change, measured continuously, was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed and with increased self-reported impaired standing balance and falls. Presence of orthostatic hypotension was associated with reduced ability to maintain standing balance in semi-tandem stance with eyes closed for both intermittent and continuous measurements and with increased self-reported impaired standing balance for continuous measurements. CONCLUSION: Continuous blood pressure measurements are of additional value to identify patients at risk of having impaired standing balance and may therefore be useful in routine geriatric care.

  2. Blood pressure as a therapeutic target in stroke.

    Science.gov (United States)

    Armario, Pedro; de la Sierra, Alejandro

    2009-01-01

    Stroke, as a clinical manifestation of the cardiovascular diseases, is one of the leading causes of death and disability in both developed and developing countries. Hypertension is by far, the most important risk factor for stroke. Epidemiological data indicate that the risk of stroke increases with both systolic and diastolic blood pressure elevation, from levels of 115/75 mmHg. It is also evident that most adults worldwide have values above these limits, thus emphasizing the importance of blood pressure as a risk factor for stroke. Clinical trials of antihypertensive treatment, both in studies that have compared active drugs against placebo or in those comparing different types of drugs have clearly demonstrated a protective effect of blood pressure reduction in the prevention of stroke. The degree of protection is directly related to blood pressure reduction and, the lower the level, the better the prognosis. Although data on secondary stroke prevention are scarcer, studies also seem to indicate that lowering blood pressure with antihypertensive treatment protects against stroke recurrence. At the present moment there is still uncertainty on 2 different aspects regarding the relationship between antihypertensive treatment and stroke. First, the blood pressure management during acute stroke has not adequately investigated in clinical trials. Second, the possibility of a protective role of specific types of antihypertensive drugs beyond blood pressure reduction is a matter of debate. Independently of these unresolved issues, prevention of hypertension development by lifestyle changes and adequate treatment and control to the hypertensive population will be a very effective measure in reducing stroke incidence, stroke recurrence, and stroke mortality.

  3. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  4. Relationship between Resting Heart Rate, Blood Pressure and Pulse Pressure in Adolescents.

    Science.gov (United States)

    Christofaro, Diego Giulliano Destro; Casonatto, Juliano; Vanderlei, Luiz Carlos Marques; Cucato, Gabriel Grizzo; Dias, Raphael Mendes Ritti

    2017-05-01

    High resting heart rate is considered an important factor for increasing mortality chance in adults. However, it remains unclear whether the observed associations would remain after adjustment for confounders in adolescents. To analyze the relationship between resting heart rate, blood pressure and pulse pressure in adolescents of both sexes. A cross-sectional study with 1231 adolescents (716 girls and 515 boys) aged 14-17 years. Heart rate, blood pressure and pulse pressure were evaluated using an oscillometric blood pressure device, validated for this population. Weight and height were measured with an electronic scale and a stadiometer, respectively, and waist circumference with a non-elastic tape. Multivariate analysis using linear regression investigated the relationship between resting heart rate and blood pressure and pulse pressure in boys and girls, controlling for general and abdominal obesity. Higher resting heart rate values were observed in girls (80.1 ± 11.0 beats/min) compared to boys (75.9 ± 12.7 beats/min) (p ≤ 0.001). Resting heart rate was associated with systolic blood pressure in boys (Beta = 0.15 [0.04; 0.26]) and girls (Beta = 0.24 [0.16; 0.33]), with diastolic blood pressure in boys (Beta = 0.50 [0.37; 0.64]) and girls (Beta = 0.41 [0.30; 0.53]), and with pulse pressure in boys (Beta = -0.16 [-0.27; -0.04]). This study demonstrated a relationship between elevated resting heart rate and increased systolic and diastolic blood pressure in both sexes and pulse pressure in boys even after controlling for potential confounders, such as general and abdominal obesity. A frequência cardíaca de repouso é considerada um importante fator de aumento de mortalidade em adultos. Entretanto, ainda é incerto se as associações observadas permanecem após ajuste para fatores de confusão em adolescentes. Analisar a relação entre frequência cardíaca de repouso, pressão arterial e pressão de pulso em adolescentes dos dois sexos. Estudo transversal

  5. The influence of blood pressure management on neurological outcome in endovascular therapy for acute ischaemic stroke.

    Science.gov (United States)

    Rasmussen, M; Espelund, U S; Juul, N; Yoo, A J; Sørensen, L H; Sørensen, K E; Johnsen, S P; Andersen, G; Simonsen, C Z

    2018-06-01

    Observational studies have suggested that low blood pressure and blood pressure variability may partially explain adverse neurological outcome after endovascular therapy with general anaesthesia (GA) for acute ischaemic stroke. The aim of this study was to further examine whether blood pressure related parameters during endovascular therapy are associated with neurological outcome. The GOLIATH trial randomised 128 patients to either GA or conscious sedation for endovascular therapy in acute ischaemic stroke. The primary outcome was 90 day modified Rankin Score. The haemodynamic protocol aimed at keeping the systolic blood pressure >140 mm Hg and mean blood pressure >70 mm Hg during the procedure. Blood pressure related parameters of interest included 20% reduction in mean blood pressure; mean blood pressure blood pressure blood pressure; mean blood pressure at the time of groin puncture; postreperfusion mean blood pressure; blood pressure variability; and use of vasopressors. Sensitivity analyses were performed in the subgroup of reperfused patients. Procedural average mean and systolic blood pressures were higher in the conscious sedation group (Pblood pressure blood pressure blood pressure variability, and use of vasopressors were all higher in the GA group (Pblood pressure related parameters and the modified Rankin Score in the overall patient population, and in the subgroup of patients with full reperfusion. We found no statistically significant association between blood pressure related parameters during endovascular therapy and neurological outcome. NCT 02317237. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  6. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  7. Oscillometric Blood Pressure Estimation: Past, Present, and Future.

    Science.gov (United States)

    Forouzanfar, Mohamad; Dajani, Hilmi R; Groza, Voicu Z; Bolic, Miodrag; Rajan, Sreeraman; Batkin, Izmail

    2015-01-01

    The use of automated blood pressure (BP) monitoring is growing as it does not require much expertise and can be performed by patients several times a day at home. Oscillometry is one of the most common measurement methods used in automated BP monitors. A review of the literature shows that a large variety of oscillometric algorithms have been developed for accurate estimation of BP but these algorithms are scattered in many different publications or patents. Moreover, considering that oscillometric devices dominate the home BP monitoring market, little effort has been made to survey the underlying algorithms that are used to estimate BP. In this review, a comprehensive survey of the existing oscillometric BP estimation algorithms is presented. The survey covers a broad spectrum of algorithms including the conventional maximum amplitude and derivative oscillometry as well as the recently proposed learning algorithms, model-based algorithms, and algorithms that are based on analysis of pulse morphology and pulse transit time. The aim is to classify the diverse underlying algorithms, describe each algorithm briefly, and discuss their advantages and disadvantages. This paper will also review the artifact removal techniques in oscillometry and the current standards for the automated BP monitors.

  8. Prognostic significance of between-arm blood pressure differences.

    Science.gov (United States)

    Agarwal, Rajiv; Bunaye, Zerihun; Bekele, Dagim M

    2008-03-01

    Blood pressure (BP) recordings often differ between arms, but the extent to which these differences are reproducible and whether the differences have prognostic importance is unknown. We enrolled 421 consecutive patients from a medicine and a renal clinic at a veterans' hospital. Three BP recordings were obtained in each arm using an oscillometric device in a sequential manner and repeated in 1 week. Patients were followed for all-cause mortality arm had 5.1-mm Hg higher systolic BP that attenuated by approximately 2.2 mm Hg a week later. Systolic BP dropped 6.9 mm Hg over 1 week and by an additional 5.3 mm Hg in patients with chronic kidney disease. Accounting for the visit and arm effect improved the reproducibility of the BP measurements. The intraclass correlation coefficient was 0.74, which improved to 0.88 after accounting for visit and 0.93 after accounting for arm. The crude mortality rate was 6.33 per 100 patient-years. Every 10-mm Hg difference in systolic BP between the arms conferred a mortality hazard of 1.24 (95% CI: 1.01 to 1.52) after adjusting for average systolic BP and chronic kidney disease. BP differences between arms are reproducible and carry prognostic information. Patients should have evaluation of BP in both arms at the screening visit.

  9. One arm exercise induces significant interarm diastolic blood pressure difference.

    Science.gov (United States)

    Hong, Dezhi; Wang, Jiwei; Su, Hai; Xu, Jingsong; Liu, Yanna; Peng, Qiang; Wang, Lijuan

    2011-06-01

    This study is designed to investigate the inducing effect of one arm exercise on interarm difference (IAD) in the blood pressure (BP). Fifty healthy young participants were included in the study. Three-minute exercises of the right arm elbow flexion and extension were performed. The bilateral brachial BP was simultaneously measured with two automatic BP measurement devices before (basic) and immediately 0, 5, 10, 15, 20, and 30 min after exercise. The absolute difference in the systolic BP (SBP) and diastolic BP (DBP) between the left and right BP of at least 10 mmHg was recognized as sIAD and dIAD. The baseline data of the SBP and DBP in left and right arms revealed no significant difference (SBP: 110 ± 10 vs. 111 ± 11 mmHg; DBP: 66 ± 8 vs. 66 ± 9 mmHg, both not significant). The prevalence of dIAD was 2% at the baseline. However, this prevalence increased to 80% at 0 min, as right arm exercise induced the right DBP decrease and left DBP increase, and then the prevalence decreased gradually within a 30-min recovery period. The prevalence of sIAD was zero at the baseline and the maximal prevalence was 8% during the 20-min postexercise period. One arm exercise can lead to a significant IAD in DBP. Any arm exercise should be avoided before BP measurement.

  10. Twenty-Four-Hour Ambulatory Blood Pressure Monitoring in Hypertension

    Science.gov (United States)

    2012-01-01

    Executive Summary Objective The objective of this health technology assessment was to determine the clinical effectiveness and cost-effectiveness of 24-hour ambulatory blood pressure monitoring (ABPM) for hypertension. Clinical Need: Condition and Target Population Hypertension occurs when either systolic blood pressure, the pressure in the artery when the heart contracts, or diastolic blood pressure, the pressure in the artery when the heart relaxes between beats, are consistently high. Blood pressure (BP) that is consistently more than 140/90 mmHg (systolic/diastolic) is considered high. A lower threshold, greater than 130/80 mmHg (systolic/diastolic), is set for individuals with diabetes or chronic kidney disease. In 2006 and 2007, the age-standardized incidence rate of diagnosed hypertension in Canada was 25.8 per 1,000 (450,000 individuals were newly diagnosed). During the same time period, 22.7% of adult Canadians were living with diagnosed hypertension. A smaller proportion of Canadians are unaware they have hypertension; therefore, the estimated number of Canadians affected by this disease may be higher. Diagnosis and management of hypertension are important, since elevated BP levels are related to the risk of cardiovascular disease, including stroke. In Canada in 2003, the costs to the health care system related to the diagnosis, treatment, and management of hypertension were over $2.3 billion (Cdn). Technology The 24-hour ABPM device consists of a standard inflatable cuff attached to a small computer weighing about 500 grams, which is worn over the shoulder or on a belt. The technology is noninvasive and fully automated. The device takes BP measurements every 15 to 30 minutes over a 24-to 28-hour time period, thus providing extended, continuous BP recordings even during a patient’s normal daily activities. Information on the multiple BP measurements can be downloaded to a computer. The main detection methods used by the device are auscultation and

  11. Renal function evaluation in the aged with normal blood pressure and high blood pressure

    International Nuclear Information System (INIS)

    Jacob Filho, W.; Carvalho Filho, E.T. de; Papaleo Netto, M.; Baptista, M.C.

    1986-01-01

    Thirty-four patients older than 65 years were divided into two groups according to their ages: I - 66 to 74 years (17 patients), II - 75 and over (17 patients). These elderly patients were also divided according to their arterial blood pressure level (BP): A - normal BP (14 patients), B high BP (20 patients). None of these patients presented any other disease that could affect kidney function, nor have used drugs that could interfere on the BP or on the kidney function. Glomerular filtration rate (GFR) and effective renal plasmatic flow (ERPF) were analysed by radioisotopic techniques. Furthermore the filtration fraction (FF) was evaluated by the GFR/ERPF ratio. The observed GFR, ERPF and FF variations in the age groups or in normotensive and hypertensive patients were not significant, but we could assume that the physiopathological mechanisms that cause a decreased GFR in consequence of age or of systemic hypertension could be of different origins. Thus in the old hypertensive patients, alterations in the autoregulated hemodynamic mechanism could occur. (author) [pt

  12. Multidisciplinary Treatment of the Metabolic Syndrome Lowers Blood Pressure Variability Independent of Blood Pressure Control.

    Science.gov (United States)

    Marcus, Yonit; Segev, Elad; Shefer, Gabi; Sack, Jessica; Tal, Brurya; Yaron, Marianna; Carmeli, Eli; Shefer, Lili; Margaliot, Miri; Limor, Rona; Gilad, Suzan; Sofer, Yael; Stern, Naftali

    2016-01-01

    Blood pressure (BP) variability (BPV) contributes to target organ damage independent of BP. The authors examined the effect of a 1-year multidisciplinary intervention on BPV in patients with the metabolic syndrome (MetS) as defined by criteria from the Third Report of the Adult Treatment Panel. Forty-four nondiabetic patients underwent clinical and biochemical profiling, 24-hour ambulatory BP monitoring (ABPM), body composition, carotid intima-media thickness, and carotid-femoral pulse wave velocity (PWV). The intervention targeted all MetS components. BPV was assessed by the standard deviation of daytime systolic BP derived from ABPM. Patients with low and high BPV (lower or higher than the median daytime standard deviation of 11.6 mm Hg) did not differ in regards to systolic and diastolic BP, age, fasting glucose, glycated hemoglobin, and body mass index, but the high-variability group had higher values of low-density lipoprotein and leg fat. The 1-year intervention resulted in weight reduction but not BP-lowering. BPV declined in the high-variability group in association with lowering of PWV, C-reactive protein, glycated hemoglobin, alanine aminotransferase, asymmetric dimethylarginine, and increased high-density lipoprotein cholesterol. A multidisciplinary intervention independent of BP-lowering normalized BPV, lowered PWV, and enhanced metabolic control. © 2015 Wiley Periodicals, Inc.

  13. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  14. Renal Nerve Stimulation-Induced Blood Pressure Changes Predict Ambulatory Blood Pressure Response After Renal Denervation.

    Science.gov (United States)

    de Jong, Mark R; Adiyaman, Ahmet; Gal, Pim; Smit, Jaap Jan J; Delnoy, Peter Paul H M; Heeg, Jan-Evert; van Hasselt, Boudewijn A A M; Lau, Elizabeth O Y; Persu, Alexandre; Staessen, Jan A; Ramdat Misier, Anand R; Steinberg, Jonathan S; Elvan, Arif

    2016-09-01

    Blood pressure (BP) response to renal denervation (RDN) is highly variable and its effectiveness debated. A procedural end point for RDN may improve consistency of response. The objective of the current analysis was to look for the association between renal nerve stimulation (RNS)-induced BP increase before and after RDN and changes in ambulatory BP monitoring (ABPM) after RDN. Fourteen patients with drug-resistant hypertension referred for RDN were included. RNS was performed under general anesthesia at 4 sites in the right and left renal arteries, both before and immediately after RDN. RNS-induced BP changes were monitored and correlated to changes in ambulatory BP at a follow-up of 3 to 6 months after RDN. RNS resulted in a systolic BP increase of 50±27 mm Hg before RDN and systolic BP increase of 13±16 mm Hg after RDN (Pefficacy of RDN and predict BP response to RDN. © 2016 American Heart Association, Inc.

  15. Estrogen replacement, vascular distensibility, and blood pressures in postmenopausal women.

    Science.gov (United States)

    De Meersman, R E; Zion, A S; Giardina, E G; Weir, J P; Lieberman, J S; Downey, J A

    1998-05-01

    The pathogenesis of blood pressure (BP) rise in aging women remains unexplained, and one of the many incriminating factors may include abnormalities in arteriolar resistance vessels. The aim of this study was to determine the effects of unopposed estrogen on arteriolar distensibility, baroreceptor sensitivity (BRS), BP changes, and rate-pressure product (RPP). We tested the hypotheses that estrogen replacement therapy (ERT) enhances arteriolar distensibility and ameliorates BRS, which leads to decreases in BP and RPP. Postmenopausal women participated in a single-blind crossover study; the participants of this study, after baseline measurements, were randomly assigned to receive estrogen (ERT) or a drug-free treatment with a 6-wk washout period between treatments. The single-blind design was instituted because subjects become unblinded due to physiological changes (i.e., fluid shifts, weight gain, and secretory changes) associated with estrogen intake. However, investigators and technicians involved in data collection and analyses remained blind. After each treatment, subjects performed identical autonomic tests, during which electrocardiograms, beat-by-beat BPs, and respiration were recorded. The area under the dicrotic notch of the BP wave was used as an index of arteriolar distensibility. The magnitude of the reflex bradycardia after a precipitous rise in BP was used to determine BRS. Power spectral analysis of heart rate variability was used to assess autonomic activity. BPs were recorded from resistance vessels in the finger using a beat-by-beat photoplethysmographic device. RPP, a noninvasive marker of myocardial oxygen consumption, was calculated. Repeated-measures analyses of variance revealed a significantly enhanced arteriolar distensibility and BRS after ERT (P factors in aging women.

  16. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Directory of Open Access Journals (Sweden)

    Senn Oliver

    2010-04-01

    Full Text Available Abstract Background Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Objective Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Outcome Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary. Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries. Methods/Design Randomised controlled study. Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system. Expected results/conclusion The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range ≤ 140/≤ 90 mmHg, yellow: blood pressure >140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg lead to better self-monitoring compared with the conventional (non-colour-coded blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. Trial registration ClinicalTrials.gov ID NCT01013467

  17. Blood pressure control to prevent decline in cognition after stroke

    Directory of Open Access Journals (Sweden)

    Ihle-Hansen H

    2015-06-01

    Full Text Available Hege Ihle-Hansen,1 Bente Thommessen,2 Morten W Fagerland,3 Anne R Øksengård,4 Torgeir B Wyller,5 Knut Engedal,6 Brynjar Fure7 1Department of Internal Medicine, Vestre Viken Hospital Trust, Bærum Hospital, Bærum, Norway; 2Department of Neurology, Akershus University Hospital, Lørenskog, Norway; 3Oslo Centre for Biostatistics and Epidemiology, Research Support Services, Oslo University Hospital, Norway; 4Department of Internal medicine, Vestre Viken Hospital Trust, Bærum Hospital, Bærum, Norway; 5Department of Geriatric Medicine, Oslo University Hospital, Oslo, Norway; 6Norwegian Centre for Dementia Research, Oslo University Hospital, Oslo, Norway; 7Norwegian Knowledge Centre for the Health Services, Oslo, Norway Background: Treatment of hypertension post-stroke preserves cognition through prevention of recurrent stroke, but it is not clear whether it prevents cognitive decline through other mechanisms. We aimed to describe changes in blood pressure from baseline to 1 year post-stroke and to evaluate the association between achieved blood pressure targets and cognitive function, mild cognitive impairment (MCI, and dementia.Methods: We included patients with first-ever stroke, and defined achieved blood pressure goals as systolic blood pressure (SBP in the categories ≤125 mmHg, ≤140 mmHg, and ≤160 mmHg, SBP reduction of ≥10 mmHg, and diastolic blood pressure (DBP reduction of ≥5 mmHg. The main outcome variables were cognitive assessments 1 year post stroke. Secondary outcomes were diagnoses of MCI or dementia.Results: Forty-one of 166 patients (25% reached SBP ≤125 mmHg after 1 year, 92/166 (55% reached SBP ≤140 mmHg, and 150/166 (90% reached SBP ≤160 mmHg. SBP was reduced by ≥10 mmHg in 44/150 (29% and DBP by ≥5 mmHg in 57/150 (38%. We did not find any statistically significant associations between cognitive test performances and different blood pressure goals (P=0.070–1.0. Nor was there any significant association

  18. Does chocolate reduce blood pressure? A meta-analysis

    Directory of Open Access Journals (Sweden)

    Ried Karin

    2010-06-01

    Full Text Available Abstract Background Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. Methods We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive. Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P Results Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change ± SE: SBP: -3.2 ± 1.9 mmHg, P = 0.001; DBP: -2.0 ± 1.3 mmHg, P = 0.003. However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 ± 3.0 mmHg; P = 0.0009; DBP: -2.7 ± 2.2 mm Hg, P = 0.01, while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 ± 2.3 mmHg, P = 0.17; DBP: -1.3 ± 1.6 mmHg, P = 0.12. Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30

  19. Phacoemulsification tip vacuum pressure: Comparison of 4 devices.

    Science.gov (United States)

    Payne, Marielle; Georgescu, Dan; Waite, Aaron N; Olson, Randall J

    2006-08-01

    To determine the vacuum pressure generated by 4 phacoemulsification devices measured at the phacoemulsification tip. University ophthalmology department. The effective vacuum pressures generated by the Sovereign (AMO), Millennium (Bausch & Lomb), Legacy AdvanTec (Alcon Laboratories), and Infiniti (Alcon Laboratories) phacoemulsification machines were measured with a device that isolated the phacoemulsification tip in a chamber connected to a pressure gauge. The 4 machines were tested at multiple vacuum limit settings, and the values were recorded after the foot pedal was fully depressed and the pressure had stabilized. The AdvanTec and Infiniti machines were tested with and without occlusion of the Aspiration Bypass System (ABS) side port (Alcon Laboratories). The Millennium machine was tested using venturi and peristaltic pumps. The machines generated pressures close to the expected at maximum vacuum settings between 100 mm Hg and 500 mm Hg with few intermachine variations. There was no significant difference between pressures generated using 19- or 20-gauge tips (Millennium and Sovereign). The addition of an ABS side port decreased vacuum by a mean of 12.1% (P < .0001). Although there were some variations in vacuum pressures among phacoemulsification machines, particularly when an aspiration bypass tip was used, these discrepancies are probably not clinically significant.

  20. Sleep deprivation increases blood pressure in healthy normotensive elderly and attenuates the blood pressure response to orthostatic challenge.

    Science.gov (United States)

    Robillard, Rébecca; Lanfranchi, Paola A; Prince, François; Filipini, Daniel; Carrier, Julie

    2011-03-01

    To determine how aging affects the impact of sleep deprivation on blood pressure at rest and under orthostatic challenge. Subjects underwent a night of sleep and 24.5 h of sleep deprivation in a crossover counterbalanced design. Sleep laboratory. Sixteen healthy normotensive men and women: 8 young adults (mean 24 years [SD 3.1], range 20-28 years) and 8 elderly adults (mean 64.1 years [SD 3.4], range 60-69 years). Sleep deprivation. Brachial cuff arterial blood pressure and heart rate were measured in semi-recumbent and upright positions. These measurements were compared across homeostatic sleep pressure conditions and age groups. Sleep deprivation induced a significant increase in systolic and diastolic blood pressure in elderly but not young adults. Moreover, sleep deprivation attenuated the systolic blood pressure orthostatic response in both age groups. Our results suggest that sleep deprivation alters the regulatory mechanisms of blood pressure and might increase the risk of hypertension in healthy normotensive elderly.

  1. [Support devices for the prevention and treatment of pressure sores].

    Science.gov (United States)

    Perrouin-Verbe, Brigite

    2014-12-01

    There is a strategy to be followed in the treatment of patients with specific pathologies placing them at high risk of pressure sores. In some cases, sophisticated support devices are used.These techniques must be combined with basic good practices.

  2. Chagas disease, a risk factor for high blood pressure.

    Science.gov (United States)

    Vicco, Miguel Hernán; Rodeles, Luz; Yódice, Agustina; Marcipar, Iván

    2014-12-01

    Chagas disease is a parasite infection caused by the protozoan Trypanosoma cruzi. Its most common complications is chronic Chagas heart disease but impairments of the systemic vasculature also has been observed. Although the different mechanisms that regulate blood pressure are disrupted, to our knowledge data on the association of hypertension and chronic Chagas disease are scarce. In this regard we evaluate whether Chagas disease constitutes a high blood pressure risk factor. We recruited 200 individuals, half of them with positive serology for T. cruzi. They were subjected to a complete clinical examination. The mean age of sampled individuals was 46.7 ± 12.3, and the mean of systolic and diastolic blood pressure were 124 ± 12 mmHg and 82 ± 10 mmHg, respectively. There were no between-group differences regarding age, sex distribution or body mass index. Chagas disease contributed significantly to high blood pressure (OR = 4, 95% CI 1.8323-7.0864, p = 0.0002). Our results reveal an important association between Chagas disease and high blood pressure, which should be contemplated by physicians in order to promote preventive cardiovascular actions in patients with Chagas disease.

  3. Cantilever arrayed blood pressure sensor for arterial applanation tonometry.

    Science.gov (United States)

    Lee, Byeungleul; Jeong, Jinwoo; Kim, Jinseok; Kim, Bonghwan; Chun, Kukjin

    2014-03-01

    The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.

  4. Goat meat does not cause increased blood pressure.

    Science.gov (United States)

    Sunagawa, Katsunori; Kishi, Tetsuya; Nagai, Ayako; Matsumura, Yuka; Nagamine, Itsuki; Uechi, Shuntoku

    2014-01-01

    While there are persistent rumors that the consumption of goat meat dishes increases blood pressure, there is no scientific evidence to support this. Two experiments were conducted to clarify whether or not blood pressure increases in conjunction with the consumption of goat meat dishes. In experiment 1, 24 Dahl/Iwai rats (15 weeks old, body weight 309.3±11.1 g) were evenly separated into 4 groups. The control group (CP) was fed a diet containing 20% chicken and 0.3% salt on a dry matter basis. The goat meat group (GM) was fed a diet containing 20% goat meat and 0.3% salt. The goat meat/salt group (GS) was fed a diet containing 20% goat meant and 3% to 4% salt. The Okinawan mugwort (Artemisia Princeps Pampan)/salt group (GY) was fed a diet containing 20% goat meat, 3% to 4% salt and 5% of freeze-dried mugwort powder. The experiment 1 ran for a period of 14 weeks during which time the blood pressure of the animals was recorded. The GS, and GY groups consumed significantly more water (pgoat meat does not cause increased blood pressure, rather the large amount of salt used in the preparation of goat meat dishes is responsible for the increase in blood pressure.

  5. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  6. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    Energy Technology Data Exchange (ETDEWEB)

    Garner, Rochelle E., E-mail: rochelle.garner@canada.ca [Health Analysis Division, Statistics Canada, Ottawa, Ontario (Canada); Levallois, Patrick [Direction de la santé environnementale et de la toxicologie, Institut National de Santé Publique du Québec, Québec City, Québec (Canada); Axe santé des populations et pratiques optimales en santé, Centre de Recherche du CHU de Québec-Université Laval, Québec City, Québec (Canada)

    2017-05-15

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure

  7. Associations between cadmium levels in blood and urine, blood pressure and hypertension among Canadian adults

    International Nuclear Information System (INIS)

    Garner, Rochelle E.; Levallois, Patrick

    2017-01-01

    Background: Cadmium has been inconsistently related to blood pressure and hypertension. The present study seeks to clarify the relationship between cadmium levels found in blood and urine, blood pressure and hypertension in a large sample of adults. Methods: The study sample included participants ages 20 through 79 from multiple cycles of the Canadian Health Measures Survey (2007 through 2013) with measured blood cadmium (n=10,099) and urinary cadmium (n=6988). Linear regression models examined the association between natural logarithm transformed cadmium levels and blood pressure (separate models for systolic and diastolic blood pressure) after controlling for known covariates. Logistic regression models were used to examine the association between cadmium and hypertension. Models were run separately by sex, smoking status, and body mass index category. Results: Men had higher mean systolic (114.8 vs. 110.8 mmHg, p<0.01) and diastolic (74.0 vs. 69.6 mmHg, p<0.01) blood pressure compared to women. Although, geometric mean blood (0.46 vs. 0.38 µg/L, p<0.01) and creatinine-adjusted standardized urinary cadmium levels (0.48 vs. 0.38 µg/L, p<0.01) were higher among those with hypertension, these differences were no longer significant after adjustment for age, sex and smoking status. In overall regression models, increases in blood cadmium were associated with increased systolic (0.70 mmHg, 95% confidence interval [CI]=0.25–1.16, p<0.01) and diastolic blood pressure (0.74 mmHg, 95% CI=0.30–1.19, p<0.01). The associations between urinary cadmium, blood pressure and hypertension were not significant in overall models. Model stratification revealed significant and negative associations between urinary cadmium and hypertension among current smokers (OR=0.61, 95% CI=0.44–0.85, p<0.01), particularly female current smokers (OR=0.52, 95% CI=0.32–0.85, p=0.01). Conclusion: This study provides evidence of a significant association between cadmium levels, blood pressure

  8. Cuffless differential blood pressure estimation using smart phones.

    Science.gov (United States)

    Chandrasekaran, Vikram; Dantu, Ram; Jonnada, Srikanth; Thiyagaraja, Shanti; Subbu, Kalyan Pathapati

    2013-04-01

    Smart phones today have become increasingly popular with the general public for their diverse functionalities such as navigation, social networking, and multimedia facilities. These phones are equipped with high-end processors, high-resolution cameras, and built-in sensors such as accelerometer, orientation-sensor, and light-sensor. According to comScore survey, 26.2% of U.S. adults use smart phones in their daily lives. Motivated by this statistic and the diverse capability of smart phones, we focus on utilizing them for biomedical applications. We present a new application of the smart phone with its built-in camera and microphone replacing the traditional stethoscope and cuff-based measurement technique, to quantify vital signs such as heart rate and blood pressure. We propose two differential blood pressure estimating techniques using the heartbeat and pulse data. The first method uses two smart phones whereas the second method replaces one of the phones with a customized external microphone. We estimate the systolic and diastolic pressure in the two techniques by computing the pulse pressure and the stroke volume from the data recorded. By comparing the estimated blood pressure values with those measured using a commercial blood pressure meter, we obtained encouraging results of 95-100% accuracy.

  9. DETERMINANTS OF SUBOPTIMAL BLOOD PRESSURE CONTROL IN HYPERTENSIVE PATIENTS: 24-HOUR AMBULATORY BLOOD PRES-SURE MONITORING

    Directory of Open Access Journals (Sweden)

    Mansoor Moazenzadeh

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: The study was conducted to define the determinants of suboptimal blood pressure (BP control among hypertensive patients under treatment and explore a predictive model for detecting the patients at risk for increased BP.    METHODS: We enrolled 97 patients (40 males, 57 females under treatment for hypertension between June 2006 and May 2007 in Shafa hospital, Kerman, Iran. BP was measured at clinic twice within 5-minute intervals. After setting up ambulatory blood pressure monitoring (ABPM, BP was measured at 30-minute intervals during the day and 60-minute intervals during the night. The frequency of increased BP (more than 140/90 mmHg was included in a regression model as dependent variable and all the others such as age, sex, body mass index (BMI, drugs and baseline clinical measurements as the predictors.    RESULTS: Increased BP was detected in 44% (95% CI: 38.79%-49.65% of all measurements during 24-hour monitoring. The frequency of increased BP had a significant relationship with BMI (b=0.35, P=0.001. Clinic's pulse pressure was a significant predicting factor for BP increase (P=0.02.    CONCLUSION: BMI and pulse pressure are the best predictors for being hypertensive during lifetime. Ineffective treatment of hypertension is frequent among the hypertensive patients.      Keywords: Blood pressure control, Pulse pressure, Ambulatory blood pressure monitoring (ABPM, BMI.

  10. Measurements of the Exerted Pressure by Pelvic Circumferential Compression Devices

    Science.gov (United States)

    Knops, Simon P; van Riel, Marcel P.J.M; Goossens, Richard H.M; van Lieshout, Esther M.M; Patka, Peter; Schipper, Inger B

    2010-01-01

    Background: Data on the efficacy and safety of non-invasive Pelvic Circumferential Compression Devices (PCCDs) is limited. Tissue damage may occur if a continuous pressure on the skin exceeding 9.3 kPa is sustained for more than two or three hours. The aim of this study was to gain insight into the pressure build-up at the interface, by measuring the PCCD-induced pressure when applying pulling forces to three different PCCDs (Pelvic Binder® , SAM-Sling ® and T-POD® ) in a simplified model. Methods: The resulting exerted pressures were measured at four ‘anatomical’ locations (right, left, posterior and anterior) in a model using a pressure measurement system consisting of pressure cuffs. Results: The exerted pressure varied substantially between the locations as well as between the PCCDs. Maximum pressures ranged from 18.9-23.3 kPa and from 19.2-27.5 kPa at the right location and left location, respectively. Pressures at the posterior location stayed below 18 kPa. At the anterior location pressures varied markedly between the different PCCDs. Conclusion: The circumferential compression by the different PCCDs showed high pressures measured at the four locations using a simplified model. Difference in design and functional characteristics of the PCCDs resulted in different pressure build-up at the four locations. When following the manufacturer’s instructions, the exerted pressure of all three PCCDs tested exceeded the tissue damaging level (9.3 kPa). In case of prolonged use in a clinical situation this might put patients at risk for developing tissue damage. PMID:20361001

  11. Intensive Blood Pressure Control Affects Cerebral Blood Flow in Type 2 Diabetes Mellitus Patients

    NARCIS (Netherlands)

    Kim, Yu-Sok; Davis, Shyrin C. A. T.; Truijen, Jasper; Stok, Wim J.; Secher, Niels H.; van Lieshout, Johannes J.

    2011-01-01

    Type 2 diabetes mellitus is associated with microvascular complications, hypertension, and impaired dynamic cerebral autoregulation. Intensive blood pressure (BP) control in hypertensive type 2 diabetic patients reduces their risk of stroke but may affect cerebral perfusion. Systemic hemodynamic

  12. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  13. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.

    Science.gov (United States)

    Pini, Claudio; Pastori, Marco; Baccheschi, Jordan; Omboni, Stefano; Parati, Gianfranco

    2007-06-01

    There is evidence that blood pressure measurement outside the doctor's office can provide valuable information for the diagnostic evaluation of hypertensive patients and for monitoring their response to treatment. Home blood pressure monitoring devices have a major role in this setting, provided that their accuracy in measuring blood pressure is demonstrated by validation studies. This study aimed at verifying whether the automatic electronic oscillometric blood pressure measuring device Artsana CSI 610 complied with the standard of accuracy indicated by the ESH International Protocol. Sequential measurements of systolic and diastolic blood pressure were obtained in 33 participants using the mercury sphygmomanometer (two observers) and the test device (one supervisor). A standard adult cuff was always employed during the study. According to the ESH validation protocol, 99 couples of test device and reference blood pressure measurements were obtained during the two phases of the study (three pairs for each of the 33 participants). The Artsana CSI 610 device successfully passed phase 1 of study validation with the number of absolute differences between test and reference device never validation study with a mean (+/-SD) device-observer difference of -1.4+/-4.8 mmHg for systolic and -0.9+/-3.5 mmHg for diastolic blood pressure. According to the results of the validation study on the basis of the ESH International Protocol, the Artsana CSI 610 can be recommended for clinical use in adults.

  14. Validity and reliability of central blood pressure estimated by upper arm oscillometric cuff pressure.

    Science.gov (United States)

    Climie, Rachel E D; Schultz, Martin G; Nikolic, Sonja B; Ahuja, Kiran D K; Fell, James W; Sharman, James E

    2012-04-01

    Noninvasive central blood pressure (BP) independently predicts mortality, but current methods are operator-dependent, requiring skill to obtain quality recordings. The aims of this study were first, to determine the validity of an automatic, upper arm oscillometric cuff method for estimating central BP (O(CBP)) by comparison with the noninvasive reference standard of radial tonometry (T(CBP)). Second, we determined the intratest and intertest reliability of O(CBP). To assess validity, central BP was estimated by O(CBP) (Pulsecor R6.5B monitor) and compared with T(CBP) (SphygmoCor) in 47 participants free from cardiovascular disease (aged 57 ± 9 years) in supine, seated, and standing positions. Brachial mean arterial pressure (MAP) and diastolic BP (DBP) from the O(CBP) device were used to calibrate in both devices. Duplicate measures were recorded in each position on the same day to assess intratest reliability, and participants returned within 10 ± 7 days for repeat measurements to assess intertest reliability. There was a strong intraclass correlation (ICC = 0.987, P difference (1.2 ± 2.2 mm Hg) for central systolic BP (SBP) determined by O(CBP) compared with T(CBP). Ninety-six percent of all comparisons (n = 495 acceptable recordings) were within 5 mm Hg. With respect to reliability, there were strong correlations but higher limits of agreement for the intratest (ICC = 0.975, P difference 0.6 ± 4.5 mm Hg) and intertest (ICC = 0.895, P difference 4.3 ± 8.0 mm Hg) comparisons. Estimation of central SBP using cuff oscillometry is comparable to radial tonometry and has good reproducibility. As a noninvasive, relatively operator-independent method, O(CBP) may be as useful as T(CBP) for estimating central BP in clinical practice.

  15. SGLT2 inhibitors: their potential reduction in blood pressure.

    Science.gov (United States)

    Maliha, George; Townsend, Raymond R

    2015-01-01

    The sodium glucose co-transporter 2 (SGLT2) inhibitors represent a promising treatment option for diabetes and its common comorbidity, hypertension. Emerging data suggests that the SGLT2 inhibitors provide a meaningful reduction in blood pressure, although the precise mechanism of the blood pressure drop remains incompletely elucidated. Based on current data, the blood pressure reduction is partially due to a combination of diuresis, nephron remodeling, reduction in arterial stiffness, and weight loss. While current trials are underway focusing on cardiovascular endpoints, the SGLT2 inhibitors present a novel treatment modality for diabetes and its associated hypertension as well as an opportunity to elucidate the pathophysiology of hypertension in diabetes. Copyright © 2015 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  16. Relation of urinary calcium and magnesium excretion to blood pressure

    DEFF Research Database (Denmark)

    Kesteloot, Hugo; Tzoulaki, Ioanna; Brown, Ian J

    2011-01-01

    Data indicate an inverse association between dietary calcium and magnesium intakes and blood pressure (BP); however, much less is known about associations between urinary calcium and magnesium excretion and BP in general populations. The authors assessed the relation of BP to 24-hour excretion...... of calcium and magnesium in 2 cross-sectional studies. The International Study of Macro- and Micro-Nutrients and Blood Pressure (INTERMAP) comprised 4,679 persons aged 40-59 years from 17 population samples in China, Japan, the United Kingdom, and the United States, and the International Cooperative Study...... on Salt, Other Factors, and Blood Pressure (INTERSALT) comprised 10,067 persons aged 20-59 years from 52 samples around the world. Timed 24-hour urine collections, BP measurements, and nutrient data from four 24-hour dietary recalls (INTERMAP) were collected. In multiple linear regression analyses...

  17. Spontaneous blood pressure oscillations in mechanically ventilated patients with sepsis

    DEFF Research Database (Denmark)

    Berg, Ronan M G; Plovsing, Ronni R; Greve, Anders M

    2016-01-01

    OBJECTIVE: In the present hypothesis-generating study, we investigated whether spontaneous blood pressure oscillations are suppressed to lower frequencies, and whether abolished oscillations are associated with an adverse outcome in mechanically ventilated patients with sepsis. METHODS: We...... retrospectively subjected invasive steady-state blood pressure recordings from 65 mechanically ventilated patients with sepsis to spectral analysis. Modified spectral bands were visually identified by plotting spectral power against frequency. RESULTS: Modified middle-frequency and low-frequency (MF' and LF......') oscillations were absent in 9% and 22% of the patients, respectively. In patients in whom spontaneous blood pressure oscillations were preserved, the MF' oscillations occurred at 0.021 Hz (median, interquartile range 0.013-0.030), whereas the LF' oscillations occurred at 0.009 Hz (median, interquartile range 0...

  18. Effects of nattokinase on blood pressure: a randomized, controlled trial.

    Science.gov (United States)

    Kim, Ji Young; Gum, Si Nae; Paik, Jean Kyung; Lim, Hyo Hee; Kim, Kyong-Chol; Ogasawara, Kazuya; Inoue, Kenichi; Park, Sungha; Jang, Yangsoo; Lee, Jong Ho

    2008-08-01

    The objective of this study was to examine the effects of nattokinase supplementation on blood pressure in subjects with pre-hypertension or stage 1 hypertension. In a randomized, double-blind, placebo-controlled trial, 86 participants ranging from 20 to 80 years of age with an initial untreated systolic blood pressure (SBP) of 130 to 159 mmHg received nattokinase (2,000 FU/capsule) or a placebo capsule for 8 weeks. Seventy-three subjects completed the protocol. Compared with the control group, the net changes in SBP and diastolic blood pressure (DBP) were -5.55 mmHg (95% confidence interval [CI], -10.5 to -0.57 mmHg; pnattokinase group compared with the control group (pnattokinase supplementation resulted in a reduction in SBP and DBP. These findings suggest that increased intake of nattokinase may play an important role in preventing and treating hypertension.

  19. Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: the CoCo trial.

    Science.gov (United States)

    Steurer-Stey, Claudia; Zoller, Marco; Chmiel Moshinsky, Corinne; Senn, Oliver; Rosemann, Thomas

    2010-04-14

    Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). Randomised controlled study. 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. ClinicalTrials.gov ID NCT01013467.

  20. Blood pressure and serum creatinine in obese female.

    Science.gov (United States)

    Asrin, M; Nessa, A; Hasan, M I; Das, R K

    2015-01-01

    Obesity is increasing in developed as well as in developing countries. This analytical cross sectional study was carried out to document the relation between blood pressure, serum creatinine and body mass index in female and to assess potential health differences among obese female and normal weight female. This study was done in the Department of Physiology, Mymensingh Medical College, Mymensingh, Bangladesh from July 2012 to June 2013. Seventy female persons volunteered as subjects. Among them 35 were within normal weight (BMI 18.5-24.9kg/m²) and 35 were obese (BMI≥30kg/m²). Non probability purposive type of sampling technique was used to select the subjects. Measurement of body mass index and blood pressure were done as per procedure. Serum creatinine level was estimated by enzymatic colorimetric method. The results were calculated and analyzed by using SPSS (statistical package for social science, version 17.0), scientific electronic calculator and simultaneously with a computer assisted program like Microsoft excel. Unpaired 't' test was applied to find the significance of difference regarding serum creatinine and blood pressure levels in obese female. The value of p was 1% to indicate highly significant and 5% to indicate simply significant or statistically significant. The mean±SE of systolic blood pressure, diastolic blood pressure and serum creatinine levels were 135.71±1.58mmHg, 88.74±0.95mmHg and 1.03±0.01mg/dl respectively; significant at 1% level for obese group of BMI (phigh BMI is significantly related to increased levels of serum creatinine & blood pressure in obese female which indicate the obese subjects are prone to cardiovascular & metabolic risk.

  1. Noise exposure at school and blood pressure in adolescents

    Directory of Open Access Journals (Sweden)

    Fadhilah Ihsani

    2017-01-01

    Full Text Available Background The increasing prevalence of primary hypertension has motivated researchers to identify influencing factors, one of which is noise. There have been few studies on a relationships between noise exposure and blood pressure in children, and none have dealt exclusively with adolescents. Objective To assess for an association between noise exposure at school and blood pressure in adolescents.   Methods To identify noisy and quiet schools, the mean noise levels of 192 senior high schools in Medan were measured using sound level meters. One noisy school and one quiet school were randomly selected for inclusion (mean noise levels of  68.2 and  53.8 dB, respectively. Students from both schools underwent blood pressure measurements by mercury sphygmomanometer. Their Body weights and heights were obtained for body mass index calculations. Subjects filled questionnaires and their parents were interviewed regarding history of illnesses. Results Of the 271 adolescents recruited, 136 (50.2% were from the noisy school. Adolescents from the noisy school had higher mean systolic and diastolic blood pressures [121.6 (SD 13.87 mmHg and 71.1 (SD 8.15 mmHg, respectively], than those from the quiet school [111.8 (SD 12.61 mmHg and 63.8 (SD 8.05 mmHg, respectively]. After adjusting for other factors, noise had a significant, moderate, positive association with systolic and diastolic blood pressures [β = 0.452; B = 6.21 (95% CI 3.86-8.55 mmHg; and β = 0.473; B = 4.18 (95% CI 2.41 to 5.94 mmHg, respectively]. Conclusion Adolescents from a noisy school have a greater risk of higher systolic and diastolic blood pressures than those from a quiet school.

  2. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  3. Follow-up of Antihypertensive Therapy Improves Blood Pressure Control: Results of HYT (HYperTension survey) Follow-up.

    Science.gov (United States)

    Fici, F; Seravalle, G; Koylan, N; Nalbantgil, I; Cagla, N; Korkut, Y; Quarti-Trevano, F; Makel, W; Grassi, G

    2017-09-01

    Although improved during the past few years, blood pressure control remains sub optimal. The impact of follow-up assessment on blood pressure control was evaluated in a group of patients of the HYT (HYperTension survey), treated with a combination of different dihydropyridine calcium-channel blockers (CCBs regimen) and inhibitors of renin-angiotensin-aldosterone system (RAAS) and with uncontrolled blood pressure. This was obtained assessing (a) the rate of blood pressure control at 3 and 6 months of follow-up in the whole group of patients, (b) the rate of blood pressure control and the average blood pressure values in subjects treated with different DHP-CCBs regimen. From the 4993 patients with uncontrolled blood pressure, (BP ≥ 140/90 or ≥140/85 in patients with diabetes), 3729 (mean age 61.2 ± 11.5 years), maintained CCBs regimen combined wih RAAS blockers and were evaluated at 3 and 6 months follow-up. At each visit BP (semiautomatic device, Omron-M6, 3 measurements), heart rate, adverse events and treatment persistence were collected. At 1st and 2nd follow-up the rate of controlled BP was 63.5 and 72.8% respectively (p blood pressure control; (b) there is no significant difference in the antihypertensive effect between different CCBs regimen; (c) lipophilic CCBs induce less ankle edema.

  4. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect...

  5. [Health and exercise: effects of exercise on high blood pressure].

    Science.gov (United States)

    Ikeda, M; Nanri, H; Himeno, E

    1993-09-01

    Many factors, such as genetic, psychological, environmental, and socioeconomical factors, influence the health of individuals. Recently behavioral risks which cause preventable chronic diseases or premature death have been increasing. These risk factors are mainly due to living habits, such as over-eating, less exercise and psychological stress. Physical activity or fitness is reported to be inversely associated with morbidity and mortality from chronic diseases, such as cardiovascular diseases diabetes mellitus, cancer and so on. Hypertension has also been reported to be associated with low physical fitness in cross-sectional studies. We have so far reported a significant blood pressure reduction in mild hypertensive patients who completed mild intensity exercise training in well controlled studies. Exercise seemed to modify the multiple factors that might participate in raising and maintaining high blood pressure. The mechanisms of lowering blood pressure by exercise training are mainly due to a depletion of blood volume or the reduction of both cardiac output and the sympathetic tone. They were supported by the evidence of increased levels of prostaglandin E, dopamine, taurine, and decreased levels of plasma norepinephrine and endogenous ouavain-like substance. In this article, we have reviewed the physiological and biochemical roles of exercise, the effects of exercise on high blood pressure, and the hypotensive mechanism of mild aerobic exercise hypertensive patients.

  6. Significance of blood pressure variability in patients with sepsis.

    Science.gov (United States)

    Pandey, Nishant Raj; Bian, Yu-Yao; Shou, Song-Tao

    2014-01-01

    This study was undertaken to observe the characteristics of blood pressure variability (BPV) and sepsis and to investigate changes in blood pressure and its value on the severity of illness in patients with sepsis. Blood parameters, APACHE II score, and 24-hour ambulatory BP were analyzed in 89 patients with sepsis. In patients with APACHE II score>19, the values of systolic blood pressure (SBPV), diasystolic blood pressure (DBPV), non-dipper percentage, cortisol (COR), lactate (LAC), platelet count (PLT) and glucose (GLU) were significantly higher than in those with APACHE II score ≤19 (Pblood cell (WBC), creatinine (Cr), PaO2, C-reactive protein (CRP), adrenocorticotropic hormone (ACTH) and tumor necrosis factor α (TNF-α) were not statistically significant (P>0.05). Correlation analysis showed that APACHE II scores correlated significantly with SBPV and DBPV (P0.05). Logistic regression analysis of SBPV, DBPV, APACHE II score, and LAC was used to predict prognosis in terms of survival and non-survival rates. Receiver operating characteristics curve (ROC) showed that DBPV was a better predictor of survival rate with an AUC value of 0.890. However, AUC of SBPV, APACHE II score, and LAC was 0.746, 0.831 and 0.915, respectively. The values of SBPV, DBPV and non-dipper percentage are higher in patients with sepsis. DBPV and SBPV can be used to predict the survival rate of patients with sepsis.

  7. Does chocolate reduce blood pressure? A meta-analysis.

    Science.gov (United States)

    Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P

    2010-06-28

    Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment groups, and interventions ran for 2 to 18 weeks. Meta-regression analysis found study design and type of control to be borderline significant but possibly indirect predictors

  8. Effects of fasting on Blood pressure in normotensive males

    Directory of Open Access Journals (Sweden)

    Fatima Samad

    2016-07-01

    Full Text Available Muslims all over the world fast in the holy month of Ramadan. Fasting means abstinence from drinking any liquids, eating, smoking and taking anything parenterally.  It is intermittent in nature from the start of dawn to end at dusk. Fasting has various physiological effects on different biological parameters of the human body. Previous studies that look at effect of Ramadan fasting on blood pressure have focused mainly on hypertensive patients and patients with already established heart disease.(1,2There is very limited data regarding the effect of fasting on the normal population. (3,4 A few previous studies have advocated a hypotensive role of fasting.(5 In our study published in Journal of Ayub Medical College Abbottabad (JAMC in 2015, “Effects of Ramadan Fasting on Blood pressure in normotensive males”, we investigated the effect of Ramadan fasting on blood pressure of normotensive men. We conducted a repeated measure observational study in Karachi, Pakistan on 70 individuals who were normotensive, non-smokers between the ages of 18–50 years. . Blood pressure, pulse, BMI of each participant was recorded one week before the start of Ramadan and in the first, second and third week of Ramadan. The results of our study show that intermittent fasting has a hypotensive effect in normotensive males as proven in animal models and certain human population. There was an average drop of 8/3 mmHg and while the results are significant, their clinical relevance needs to be analysed. Studies on animal models have suggested atrial natriuretic peptide, catecholamines, opiates and body mass index as possible reasons for the decrease in blood pressure due to fasting.(3, 6  Dewanti et al suggested that the cause of drop in blood pressure was the drop in BMI however in our study we found that a drop in BMI only occurred before Iftar towards the end of the fast. There was no significant drop in post-Iftar BMI although there was a significant drop in blood

  9. Relationship between blood manganese and blood pressure in the Korean general population according to KNHANES 2008

    International Nuclear Information System (INIS)

    Lee, Byung-Kook; Kim, Yangho

    2011-01-01

    Introduction: We present data on the association of manganese (Mn) level with hypertension in a representative sample of the adult Korean population who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) 2008. Methods: This study was based on the data obtained by KNHANES 2008, which was conducted for three years (2007-2009) using a rolling sampling design involving a complex, stratified, multistage, probability-cluster survey of a representative sample of the noninstitutionalized civilian population of South Korea. Results: Multiple regression analysis after controlling for covariates, including gender, age, regional area, education level, smoking, drinking status, hemoglobin, and serum creatinine, showed that the beta coefficients of log blood Mn were 3.514, 1.878, and 2.517 for diastolic blood pressure, and 3.593, 2.449, and 2.440 for systolic blood pressure in female, male, and all participants, respectively. Multiple regression analysis including three other blood metals, lead, mercury, and cadmium, revealed no significant effects of the three metals on blood pressure and showed no effect on the association between blood Mn and blood pressure. In addition, doubling the blood Mn increased the risk of hypertension 1.828, 1.573, and 1.567 fold in women, men, and all participants, respectively, after adjustment for covariates. The addition of blood lead, mercury, and cadmium as covariates did not affect the association between blood Mn and the prevalence of hypertension. Conclusion: Blood Mn level was associated with an increased risk of hypertension in a representative sample of the Korean adult population. - Highlights: → We showed the association of manganese with hypertension in Korean population. → This study was based on the data obtained by KNHANES 2008. → Blood manganese level was associated with an increased risk of hypertension.

  10. Secular trends of blood pressure in A-bomb survivors

    International Nuclear Information System (INIS)

    Sasaki, Hideo; Kodama, Kazunori; Kitano, Koei

    1986-01-01

    There has been controversy about whether or not radiation exposure plays a major role in advancing age. To preliminarily study this relationship, a statistical analysis was made on blood pressure measurements in a cohort of A-bomb survivors for Adult Health Study carried out during a 22-year period from 1958 through 1980. Systolic blood pressure increased with advancing age in both men and women between 30 and 80 years. During the years 1974 through 1980, it tended to increase in both men and women aged in their thirties and fourties. Diastolic blood pressure for men increased between the ages of 30 and 60 years, and decreased between the ages of 60 and 80 years. It tended to increase from year to year for men. For women, it decreased prior to the 1970's, and thereafter, tended to increase. The parameters, including systolic and diastolic blood pressures and pulse pressure, were independent of exposure doses in the subgroups according to age or sex. (Namekawa, K.)

  11. Leak detection device for nuclear reactor pressure vessel

    International Nuclear Information System (INIS)

    Ikeda, Jun.

    1988-01-01

    Purpose: To test the leakage of a nuclear reactor pressure vessel during stopping for a short period of time with no change to the pressure vessel itself. Constitution: The device of the present invention comprises two O-rings disposed on the flange surface that connects a pressure vessel main body and an upper cover, a leak-off pipeway derived from the gap of the O-rings at the flange surface to the outside of the pressure vessel, a pressure detection means connected to the end of the pipeway, a humidity detection means disposed to the lead-off pipeway, a humidity detection means disposed to the lead-off pipeway, and gas supply means and gas suction means disposed each by way of a check valve to a side pipe branched from the pipeway. After stopping the operation of the nuclear reactor and pressurizing the pressure vessel by filling water, gases supplied to the gap between the O-rings at the flange surface by opening the check valve. In a case where water in the pressure vessel should leak to the flange surface, when gas suction is applied by properly opening the check valve, increase in the humidity due to the steams of leaked water diffused into the gas is detected to recognize the occurrence of leakage. (Kamimura, M.)

  12. Remote controlled stud bolt handling device for reactor pressure vessel

    International Nuclear Information System (INIS)

    Shindo, Takenori; Shigehiro, Katsuya; Ito, Morio; Okada, Kenji

    1988-01-01

    In nuclear power stations, at the time of regular inspection, the works of opening and fixing the upper covers of reactor pressure vessels are carried out for inspecting the inside of reactor pressure vessels and exchanging fuel rods. These upper covers are fastened with many stud bolts, therefore, the works of opening and fixing require a large amount of labor, and are done under the restricted condition of wearing protective clothings and masks. Babcock Hitachi K.K. has completed the development of a remotely controlled automatic bolt tightenig device for this purpose, therefore, its outline is reported. The conventional method of these works and the problems in it are described. The design of the new device aimed at the parallel execution of cleaning screw threads, loosening and tightening nuts, and taking off and putting on nuts and washers, thus contributing to the shortening of regular inspection period, the reduction of the radiation exposure of workers, and the decrease of the number of workers. The function, reliability and endurance of the new device were confirmed by the verifying test using a device made for trial. The device is composed of a stand, a rail and four stations each with a cleaning unit, a stud tensioner and a nut handling unit. (K.I.)

  13. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk

    NARCIS (Netherlands)

    G.B. Ehret (Georg); P. Munroe (Patricia); K.M. Rice (Kenneth); M. Bochud (Murielle); A.D. Johnson (Andrew); D.I. Chasman (Daniel); A.V. Smith (Albert Vernon); M.D. Tobin (Martin); G.C. Verwoert (Germaine); S.J. Hwang; V. Pihur (Vasyl); P. Vollenweider (Peter); P.F. O'Reilly (Paul); N. Amin (Najaf); J.L. Bragg-Gresham (Jennifer L.); A. Teumer (Alexander); N.L. Glazer (Nicole); L.J. Launer (Lenore); J.H. Zhao (Jing Hua); Y.S. Aulchenko (Yurii); S.C. Heath (Simon); S. Sõber (Siim); A. Parsa (Afshin); J. Luan; P. Arora (Pankaj); A. Dehghan (Abbas); F. Zhang (Feng); G. Lucas (Gavin); A.A. Hicks (Andrew); A.U. Jackson (Anne); J. Peden (John); T. Tanaka (Toshiko); S.H. Wild (Sarah); I. Rudan (Igor); W. Igl (Wilmar); Y. Milaneschi (Yuri); A.N. Parker (Alex); C. Fava (Cristiano); J.C. Chambers (John); E.R. Fox (Ervin); M. Kumari (Meena); M. Jin Go (Min); P. van der Harst (Pim); W. Hong Linda Kao (Wen); M. Sjögren (Marketa); D.G. Vinay; M. Alexander (Myriam); Y. Tabara (Yasuharu); S. Shaw-Hawkins (Sue); P.H. Whincup (Peter); Y. Liu (YongMei); G. Shi (Gang); J. Kuusisto (Johanna); B. Tayo (Bamidele); M. Seielstad (Mark); X. Sim (Xueling); K.-D. Hoang Nguyen; T. Lehtimäki (Terho); G. Matullo (Giuseppe); Y. Wu (Ying); T.R. Gaunt (Tom); N. Charlotte Onland-Moret; M.N. Cooper (Matthew); C. Platou (Carl); E. Org (Elin); R. Hardy (Rebecca); S. Dahgam (Santosh); J. Palmen (Jutta); V. Vitart (Veronique); P.S. Braund (Peter); T. Kuznetsova (Tatiana); C.S.P.M. Uiterwaal (Cuno); A. Adeyemo (Adebowale); W. Palmas (Walter); H. Campbell (Harry); B. Ludwig (Barbara); M. Tomaszewski; I. Tzoulaki; N.D. Palmer (Nicholette); T. Aspelund (Thor); M. Garcia (Melissa); Y.-P.C. Chang (Yen-Pei); J.R. O´Connell; N.I. Steinle (Nanette); D.E. Grobbee (Diederick); D.E. Arking (Dan); S.L. Kardia (Sharon); A.C. Morrison (Alanna); D.G. Hernandez (Dena); S.S. Najjar (Samer); W.L. McArdle (Wendy); D. Hadley (David); M.J. Brown (Morris); J. Connell (John); A. Hingorani (Aroon); I.N.M. Day (Ian); D.A. Lawlor (Debbie); J.P. Beilby (John); R.W. Lawrence (Robert); R. Clarke; J. Hopewell; H. Ongen (Halit); A.W. Dreisbach (Albert); Y. Li (Yali); J. Hunter Young; J.C. Bis (Joshua); M. Kähönen (Mika); J. Viikari (Jorma); N.R. Lee (Nanette); M-H. Chen (Ming-Huei); M. Olden (Matthias); C. Pattaro (Cristian); J.A. Hoffman Bolton (Judith); A. Köttgen (Anna); S.M. Bergmann (Sven); V. Mooser (Vincent); N. Chaturvedi (Nish); T.M. Frayling (Timothy); M. Islam (Muhammad); T.H. Jafar (Tazeen); S.R. Kulkarni (Smita); S.R. Bornstein (Stefan); J. Gräßler (Jürgen); L. Groop (Leif); B.F. Voight (Benjamin); J. Kettunen (Johannes); P. Howard (Philip); A. Taylor (Andrew); S. Guarrera (Simonetta); F. Ricceri (Fulvio); V. Emilsson (Valur); A.S. Plump (Andrew); K-T. Khaw (Kay-Tee); A.B. Weder (Alan); S.C. Hunt (Steven); Y.V. Sun (Yan); R.N. Bergman (Richard); F.S. Collins (Francis); L.L. Bonnycastle (Lori); L.J. Scott (Laura); H.M. Stringham (Heather); L. Peltonen (Leena Johanna); M. Perola (Markus); E. Vartiainen (Erkki); S.-M. Brand; J.A. Staessen (Jan); Y.A. Wang (Ying); P.R. Burton (Paul); M. Soler Artigas (Maria); Y. Dong (Yanbin); H. Snieder (Harold); H. Zhu (Haidong); K. Lohman (Kurt); M.E. Rudock (Megan); S.R. Heckbert (Susan); K.L. Wiggins (Kerri); A. Doumatey (Ayo); D. Shriner (Daniel); G. Veldre (Gudrun); M. Viigimaa (Margus); S. Kinra (Sanjay); D. Prabhakaran (Dorairaj); V. Tripathy (Vikal); C.D. Langefeld (Carl); A. Rosengren (Annika); D.S. Thelle (Dag); A. Maria Corsi (Anna); A. Singleton (Andrew); T. Forrester (Terrence); G. Hilton (Gina); C.A. McKenzie (Colin); T. Salako (Tunde); N. Iwai (Naoharu); Y. Kita (Yoshikuni); T. Ogihara (Toshio); T. Ohkubo (Takayoshi); T. Okamura (Tomonori); H. Ueshima (Hirotsugu); S. Umemura (Satoshi); S. Eyheramendy (Susana); T. Meitinger (Thomas); H.E. Wichmann (Heinz Erich); Y. Shin Cho (Yoon); H.-L. Kim; J.S. Sehmi (Joban); B. Hedblad (Bo); P. Nilsson (Peter); G. Davey-Smith (George); A. Wong (Andrew); N. Narisu (Narisu); A. Stancáková (Alena); L.J. Raffel (Leslie); J. Yao (Jie); S. Kathiresan (Sekar); C.J. O'Donnell (Christopher); S.M. Schwartz (Stephen); M.A. Ikram (Arfan); W.T. Longstreth Jr; T.H. Mosley (Thomas); S. Seshadri (Sudha); N.R.G. Shrine (Nick); L.V. Wain (Louise); M.A. Morken (Mario); A.J. Swift (Amy); J. Laitinen (Jaana); I. Prokopenko (Inga); P. Zitting (Paavo); S.E. Humphries (Steve); J. Danesh (John); A. Rasheed (Asif); A. Goel (Anuj); A. Hamsten (Anders); H. Watkins (Hugh); W.H. van Gilst (Wiek); C.S. Janipalli (Charles); K. Radha Mani; C. Yajnik (Chittaranjan); A. Hofman (Albert); F.U.S. Mattace Raso (Francesco); B.A. Oostra (Ben); A. Demirkan (Ayşe); A.J. Isaacs (Aaron); F. Rivadeneira Ramirez (Fernando); E. Lakatta (Edward); M. Orrù (Marco); A. Scuteri (Angelo); M. Ala-Korpela (Mika); A.J. Kangas (Antti); L.-P. Lyytikäinen (Leo-Pekka); P. Soininen (Pasi); T. Tukiainen (Taru); P. Würtz (Peter); R. Twee-Hee Ong (Rick); M. Dörr (Marcus); H.K. Kroemer (Heyo); U. Völker (Uwe); H. Völzke (Henry); P. Galan (Pilar); S. Hercberg (Serge); G.M. Lathrop (Mark); D. Zelenika (Diana); P. Deloukas (Panagiotis); M. Mangino (Massimo); T.D. Spector (Timothy); G. Zhai (Guangju); J.F. Meschia (James F.); M.A. Nalls (Michael); P. Sharma (Pankaj); J. Terzic (Janos); M.V. Kranthi Kumar; M. Denniff (Matthew); E. Zukowska-Szczechowska (Ewa); L.E. Wagenknecht (Lynne); F. Gerald R. Fowkes; F.J. Charchar (Fadi); P.E.H. Schwarz (Peter); C. Hayward (Caroline); X. Guo (Xiuqing); C. Rotimi (Charles); M.L. Bots (Michiel); N.J. Samani (Nilesh); O. Polasek (Ozren); P.J. Talmud (Philippa); F. Nyberg (Fredrik); D. Kuh (Diana); M. Laan (Maris); K. Hveem (Kristian); Y.T. van der Schouw (Yvonne); J.P. Casas (Juan); K.L. Mohlke (Karen); P. Vineis (Paolo); O. Raitakari (Olli); S.K. Ganesh (Santhi); E. Shyong Tai; M. Laakso (Markku); D.C. Rao (Dabeeru C.); T.B. Harris (Tamara); R.W. Morris (Richard); A. Dominiczak (Anna); M. Kivimaki (Mika); M. Marmot (Michael); T. Miki (Tetsuro); D. Saleheen; G.R. Chandak (Giriraj); J. Coresh (Josef); G. Navis (Gerjan); V. Salomaa (Veikko); B.-G. Han; J.S. Kooner (Jaspal); O. Melander (Olle); P.M. Ridker (Paul); S. Bandinelli (Stefania); U. Gyllensten (Ulf); A.F. Wright (Alan); J.F. Wilson (James); L. Ferrucci (Luigi); M. Farrall (Martin); J. Tuomilehto (Jaakko); P.P. Pramstaller (Peter Paul); R. Elosua (Roberto); N. Soranzo (Nicole); E.J.G. Sijbrands (Eric); D. Altshuler (David); R.J.F. Loos (Ruth); A.R. Shuldiner (Alan); C. Gieger (Christian); P. Meneton (Pierre); A.G. Uitterlinden (André); N.J. Wareham (Nick); V. Gudnason (Vilmundur); J.I. Rotter (Jerome); R. Rettig (Rainer); M. Uda (Manuela); D.P. Strachan (David); J.C.M. Witteman (Jacqueline); A.L. Hartikainen; J.S. Beckmann (Jacques); E.A. Boerwinkle (Eric); J. Erdmann (Jeanette); R.S. Vasan (Ramachandran Srini); M. Boehnke (Michael); M.G. Larson (Martin); M.R. Järvelin; B.M. Psaty (Bruce); P. Tikka-Kleemola (Päivi); C. Newton-Cheh (Christopher); P. Elliott (Paul); D. Levy (Daniel); M. Caulfield (Mark); G.R. Abecasis (Gonçalo); L.S. Adair (Linda); S.J.L. Bakker (Stephan); I.E. Barroso (Inês)

    2011-01-01

    textabstractBlood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140mmg Hg systolic blood pressure ≥90mmg Hg diastolic blood pressure). Even small increments in blood pressure are

  14. Genetic variants in novel pathways influence blood pressure and cardiovascular disease risk

    NARCIS (Netherlands)

    Ehret, Georg B.; Munroe, Patricia B.; Rice, Kenneth M.; Bochud, Murielle; Johnson, Andrew D.; Chasman, Daniel I.; Smith, Albert V.; Tobin, Martin D.; Verwoert, Germaine C.; Hwang, Shih-Jen; Pihur, Vasyl; Vollenweider, Peter; O'Reilly, Paul F.; Amin, Najaf; Bragg-Gresham, Jennifer L.; Teumer, Alexander; Glazer, Nicole L.; Launer, Lenore; Zhao, Jing Hua; Aulchenko, Yurii; Heath, Simon; Sõber, Siim; Parsa, Afshin; Luan, Jian'an; Arora, Pankaj; Dehghan, Abbas; Zhang, Feng; Lucas, Gavin; Hicks, Andrew A.; Jackson, Anne U.; Peden, John F.; Tanaka, Toshiko; Wild, Sarah H.; Rudan, Igor; Igl, Wilmar; Milaneschi, Yuri; Parker, Alex N.; Fava, Cristiano; Chambers, John C.; Fox, Ervin R.; Kumari, Meena; Go, Min Jin; van der Harst, Pim; Kao, Wen Hong Linda; Sjögren, Marketa; Vinay, D. G.; Alexander, Myriam; Tabara, Yasuharu; Shaw-Hawkins, Sue; Whincup, Peter H.; Liu, Yongmei; Shi, Gang; Kuusisto, Johanna; Tayo, Bamidele; Seielstad, Mark; Sim, Xueling; Nguyen, Khanh-Dung Hoang; Lehtimäki, Terho; Matullo, Giuseppe; Wu, Ying; Gaunt, Tom R.; Onland-Moret, N. Charlotte; Cooper, Matthew N.; Platou, Carl G. P.; Org, Elin; Hardy, Rebecca; Dahgam, Santosh; Palmen, Jutta; Vitart, Veronique; Braund, Peter S.; Kuznetsova, Tatiana; Uiterwaal, Cuno S. P. M.; Adeyemo, Adebowale; Palmas, Walter; Campbell, Harry; Ludwig, Barbara; Tomaszewski, Maciej; Tzoulaki, Ioanna; Palmer, Nicholette D.; Aspelund, Thor; Garcia, Melissa; Chang, Yen-Pei C.; O'Connell, Jeffrey R.; Steinle, Nanette I.; Grobbee, Diederick E.; Arking, Dan E.; Kardia, Sharon L.; Morrison, Alanna C.; Hernandez, Dena; Najjar, Samer; McArdle, Wendy L.; Hadley, David; Brown, Morris J.; Connell, John M.; Hingorani, Aroon D.; Day, Ian N. M.; Lawlor, Debbie A.; Beilby, John P.; Lawrence, Robert W.; Clarke, Robert; Hopewell, Jemma C.; Ongen, Halit; Dreisbach, Albert W.; Li, Yali; Young, J. Hunter; Bis, Joshua C.; Kähönen, Mika; Viikari, Jorma; Adair, Linda S.; Lee, Nanette R.; Chen, Ming-Huei; Olden, Matthias; Pattaro, Cristian; Bolton, Judith A. Hoffman; Köttgen, Anna; Bergmann, Sven; Mooser, Vincent; Chaturvedi, Nish; Frayling, Timothy M.; Islam, Muhammad; Jafar, Tazeen H.; Erdmann, Jeanette; Kulkarni, Smita R.; Bornstein, Stefan R.; Grässler, Jürgen; Groop, Leif; Voight, Benjamin F.; Kettunen, Johannes; Howard, Philip; Taylor, Andrew; Guarrera, Simonetta; Ricceri, Fulvio; Emilsson, Valur; Plump, Andrew; Barroso, Inês; Khaw, Kay-Tee; Weder, Alan B.; Hunt, Steven C.; Sun, Yan V.; Bergman, Richard N.; Collins, Francis S.; Bonnycastle, Lori L.; Scott, Laura J.; Stringham, Heather M.; Peltonen, Leena; Perola, Markus; Vartiainen, Erkki; Brand, Stefan-Martin; Staessen, Jan A.; Wang, Thomas J.; Burton, Paul R.; Artigas, Maria Soler; Dong, Yanbin; Snieder, Harold; Wang, Xiaoling; Zhu, Haidong; Lohman, Kurt K.; Rudock, Megan E.; Heckbert, Susan R.; Smith, Nicholas L.; Wiggins, Kerri L.; Doumatey, Ayo; Shriner, Daniel; Veldre, Gudrun; Viigimaa, Margus; Kinra, Sanjay; Prabhakaran, Dorairaj; Tripathy, Vikal; Langefeld, Carl D.; Rosengren, Annika; Thelle, Dag S.; Corsi, Anna Maria; Singleton, Andrew; Forrester, Terrence; Hilton, Gina; McKenzie, Colin A.; Salako, Tunde; Iwai, Naoharu; Kita, Yoshikuni; Ogihara, Toshio; Ohkubo, Takayoshi; Okamura, Tomonori; Ueshima, Hirotsugu; Umemura, Satoshi; Eyheramendy, Susana; Meitinger, Thomas; Wichmann, H.-Erich; Cho, Yoon Shin; Kim, Hyung-Lae; Lee, Jong-Young; Scott, James; Sehmi, Joban S.; Zhang, Weihua; Hedblad, Bo; Nilsson, Peter; Smith, George Davey; Wong, Andrew; Narisu, Narisu; Stančáková, Alena; Raffel, Leslie J.; Yao, Jie; Kathiresan, Sekar; O'Donnell, Christopher J.; Schwartz, Stephen M.; Ikram, M. Arfan; Longstreth, W. T.; Mosley, Thomas H.; Seshadri, Sudha; Shrine, Nick R. G.; Wain, Louise V.; Morken, Mario A.; Swift, Amy J.; Laitinen, Jaana; Prokopenko, Inga; Zitting, Paavo; Cooper, Jackie A.; Humphries, Steve E.; Danesh, John; Rasheed, Asif; Goel, Anuj; Hamsten, Anders; Watkins, Hugh; Bakker, Stephan J. L.; van Gilst, Wiek H.; Janipalli, Charles S.; Mani, K. Radha; Yajnik, Chittaranjan S.; Hofman, Albert; Mattace-Raso, Francesco U. S.; Oostra, Ben A.; Demirkan, Ayse; Isaacs, Aaron; Rivadeneira, Fernando; Lakatta, Edward G.; Orru, Marco; Scuteri, Angelo; Ala-Korpela, Mika; Kangas, Antti J.; Lyytikäinen, Leo-Pekka; Soininen, Pasi; Tukiainen, Taru; Würtz, Peter; Ong, Rick Twee-Hee; Dörr, Marcus; Kroemer, Heyo K.; Völker, Uwe; Völzke, Henry; Galan, Pilar; Hercberg, Serge; Lathrop, Mark; Zelenika, Diana; Deloukas, Panos; Mangino, Massimo; Spector, Tim D.; Zhai, Guangju; Meschia, James F.; Nalls, Michael A.; Sharma, Pankaj; Terzic, Janos; Kumar, M. V. Kranthi; Denniff, Matthew; Zukowska-Szczechowska, Ewa; Wagenknecht, Lynne E.; Fowkes, F. Gerald R.; Charchar, Fadi J.; Schwarz, Peter E. H.; Hayward, Caroline; Guo, Xiuqing; Rotimi, Charles; Bots, Michiel L.; Brand, Eva; Samani, Nilesh J.; Polasek, Ozren; Talmud, Philippa J.; Nyberg, Fredrik; Kuh, Diana; Laan, Maris; Hveem, Kristian; Palmer, Lyle J.; van der Schouw, Yvonne T.; Casas, Juan P.; Mohlke, Karen L.; Vineis, Paolo; Raitakari, Olli; Ganesh, Santhi K.; Wong, Tien Y.; Tai, E. Shyong; Cooper, Richard S.; Laakso, Markku; Rao, Dabeeru C.; Harris, Tamara B.; Morris, Richard W.; Dominiczak, Anna F.; Kivimaki, Mika; Marmot, Michael G.; Miki, Tetsuro; Saleheen, Danish; Chandak, Giriraj R.; Coresh, Josef; Navis, Gerjan; Salomaa, Veikko; Han, Bok-Ghee; Zhu, Xiaofeng; Kooner, Jaspal S.; Melander, Olle; Ridker, Paul M.; Bandinelli, Stefania; Gyllensten, Ulf B.; Wright, Alan F.; Wilson, James F.; Ferrucci, Luigi; Farrall, Martin; Tuomilehto, Jaakko; Pramstaller, Peter P.; Elosua, Roberto; Soranzo, Nicole; Sijbrands, Eric J. G.; Altshuler, David; Loos, Ruth J. F.; Shuldiner, Alan R.; Gieger, Christian; Meneton, Pierre; Uitterlinden, Andre G.; Wareham, Nicholas J.; Gudnason, Vilmundur; Rotter, Jerome I.; Rettig, Rainer; Uda, Manuela; Strachan, David P.; Witteman, Jacqueline C. M.; Hartikainen, Anna-Liisa; Beckmann, Jacques S.; Boerwinkle, Eric; Vasan, Ramachandran S.; Boehnke, Michael; Larson, Martin G.; Järvelin, Marjo-Riitta; Psaty, Bruce M.; Abecasis, Gonçalo R.; Chakravarti, Aravinda; Elliott, Paul; van Duijn, Cornelia M.; Newton-Cheh, Christopher; Levy, Daniel; Caulfield, Mark J.; Johnson, Toby; Tang, Hua; Knowles, Joshua; Hlatky, Mark; Fortmann, Stephen; Assimes, Themistocles L.; Quertermous, Thomas; Go, Alan; Iribarren, Carlos; Absher, Devin; Risch, Neil; Myers, Richard; Sidney, Steven; Ziegler, Andreas; Schillert, Arne; Bickel, Christoph; Sinning, Christoph; Rupprecht, Hans J.; Lackner, Karl; Wild, Philipp; Schnabel, Renate; Blankenberg, Stefan; Zeller, Tanja; Münzel, Thomas; Perret, Claire; Cambien, Francois; Tiret, Laurence; Nicaud, Viviane; Proust, Carole; Uitterlinden, Andre; van Duijn, Cornelia; Whitteman, Jaqueline; Cupples, L. Adrienne; Demissie-Banjaw, Serkalem; Ramachandran, Vasan; Smith, Albert; Folsom, Aaron; Morrison, Alanna; Chen, Ida Yii-Der; Bis, Joshua; Volcik, Kelly; Rice, Kenneth; Taylor, Kent D.; Marciante, Kristin; Smith, Nicholas; Glazer, Nicole; Heckbert, Susan; Harris, Tamara; Lumley, Thomas; Kong, Augustine; Thorleifsson, Gudmar; Thorgeirsson, Gudmundur; Holm, Hilma; Gulcher, Jeffrey R.; Stefansson, Kari; Andersen, Karl; Gretarsdottir, Solveig; Thorsteinsdottir, Unnur; Preuss, Michael; Schreiber, Stefan; König, Inke R.; Lieb, Wolfgang; Hengstenberg, Christian; Schunkert, Heribert; Fischer, Marcus; Grosshennig, Anika; Medack, Anja; Stark, Klaus; Linsel-Nitschke, Patrick; Bruse, Petra; Aherrahrou, Zouhair; Peters, Annette; Loley, Christina; Willenborg, Christina; Nahrstedt, Janja; Freyer, Jennifer; Gulde, Stephanie; Doering, Angela; Meisinger, Christina; Klopp, Norman; Illig, Thomas; Meinitzer, Andreas; Tomaschitz, Andreas; Halperin, Eran; Dobnig, Harald; Scharnagl, Hubert; Kleber, Marcus; Laaksonen, Reijo; Pilz, Stefan; Grammer, Tanja B.; Stojakovic, Tatjana; Renner, Wilfried; März, Winfried; Böhm, Bernhard O.; Winkelmann, Bernhard R.; Winkler, Karl; Hoffmann, Michael M.; Siscovick, David S.; Musunuru, Kiran; Barbalic, Maja; Guiducci, Candace; Burtt, Noel; Gabriel, Stacey B.; Stewart, Alexandre F. R.; Wells, George A.; Chen, Li; Jarinova, Olga; Roberts, Robert; McPherson, Ruth; Dandona, Sonny; Pichard, Augusto D.; Rader, Daniel J.; Devaney, Joe; Lindsay, Joseph M.; Kent, Kenneth M.; Qu, Liming; Satler, Lowell; Burnett, Mary Susan; Li, Mingyao; Reilly, Muredach P.; Wilensky, Robert; Waksman, Ron; Epstein, Stephen; Matthai, William; Knouff, Christopher W.; Waterworth, Dawn M.; Hakonarson, Hakon H.; Walker, Max C.; Hall, Alistair S.; Balmforth, Anthony J.; Wright, Benjamin J.; Nelson, Chris; Thompson, John R.; Ball, Stephen G.; Felix, Janine F.; Demissie, Serkalem; Loehr, Laura R.; Rosamond, Wayne D.; Folsom, Aaron R.; Benjamin, Emelia; Aulchenko, Yurii S.; Haritunians, Talin; Couper, David; Murabito, Joanne; Wang, Ying A.; Stricker, Bruno H.; Gottdiener, John S.; Chang, Patricia P.; Willerson, James T.; Köttgen, A.; Pattaro, C.; Böger, C. A.; Fuchsberger, C.; Olden, M.; Glazer, N. L.; Parsa, A.; Gao, X.; Yang, Q.; Smith, A. V.; O'Connell, J. R.; Li, M.; Schmidt, H.; Tanaka, T.; Isaacs, A.; Ketkar, S.; Hwang, S. J.; Johnson, A. D.; Dehghan, A.; Teumer, A.; Paré, G.; Atkinson, E. J.; Zeller, T.; Lohman, K.; Cornelis, M. C.; Probst-Hensch, N. M.; Kronenberg, F.; Tönjes, A.; Hayward, C.; Aspelund, T.; Eiriksdottir, G.; Launer, L. J.; Harris, T. B.; Rampersaud, E.; Mitchell, B. D.; Arking, D. E.; Boerwinkle, E.; Struchalin, M.; Cavalieri, M.; Singleton, A.; Giallauria, F.; Metter, J.; de Boer, J.; Haritunians, T.; Lumley, T.; Siscovick, D.; Psaty, B. M.; Zillikens, M. C.; Oostra, B. A.; Feitosa, M.; Province, M.; de Andrade, M.; Turner, S. T.; Schillert, A.; Ziegler, A.; Wild, P. S.; Schnabel, R. B.; Wilde, S.; Munzel, T. F.; Leak, T. S.; Illig, T.; Klopp, N.; Meisinger, C.; Wichmann, H. E.; Koenig, W.; Zgaga, L.; Zemunik, T.; Kolcic, I.; Minelli, C.; Hu, F. B.; Johansson, A.; Igl, W.; Zaboli, G.; Wild, S. H.; Wright, A. F.; Campbell, H.; Ellinghaus, D.; Schreiber, S.; Aulchenko, Y. S.; Felix, J. F.; Rivadeneira, F.; Uitterlinden, A. G.; Hofman, A.; Imboden, M.; Nitsch, D.; Brandstätter, A.; Kollerits, B.; Kedenko, L.; Mägi, R.; Stumvoll, M.; Kovacs, P.; Boban, M.; Campbell, S.; Endlich, K.; Völzke, H.; Kroemer, H. K.; Nauck, M.; Völker, U.; Polasek, O.; Vitart, V.; Badola, S.; Parker, A. N.; Ridker, P. M.; Kardia, S. L.; Blankenberg, S.; Liu, Y.; Curhan, G. C.; Franke, A.; Rochat, T.; Paulweber, B.; Prokopenko, I.; Wang, W.; Gudnason, V.; Shuldiner, A. R.; Coresh, J.; Schmidt, R.; Ferrucci, L.; Shlipak, M. G.; van Duijn, C. M.; Borecki, I.; Krämer, B. K.; Rudan, I.; Gyllensten, U.; Wilson, J. F.; Witteman, J. C.; Pramstaller, P. P.; Rettig, R.; Hastie, N.; Chasman, D. I.; Kao, W. H.; Heid, I. M.; Fox, C. S.; Vasan, R. S.; Lieb, W.; Felix, S. B.; Watzinger, N.; Larson, M. G.; Smith, N. L.; Grosshennig, A.; Kathiresan, S.; König, I. R.; Homuth, G.; Aragam, J.; Bis, J. C.; Erdmann, J.; Dörr, M.; Zweiker, R.; Lind, L.; Rodeheffer, R. J.; Greiser, K. H.; Levy, D.; Deckers, J. W.; Stritzke, J.; Lackner, K. J.; Ingelsson, E.; Kullo, I.; Haerting, J.; O'Donnell, C. J.; Heckbert, S. R.; Stricker, B. H.; Reffelmann, T.; Redfield, M. M.; Werdan, K.; Mitchell, G. F.; Rice, K.; Arnett, D. K.; Gottdiener, J. S.; Meitinger, T.; Blettner, M.; Friedrich, N.; Wang, T. J.; Benjamin, E. J.; Rotter, J. I.; Schunkert, H.; Chambers, J. C.; Zhang, W.; Lord, G. M.; van der Harst, P.; Lawlor, D. A.; Sehmi, J. S.; Gale, D. P.; Wass, M. N.; Ahmadi, K. R.; Bakker, S. J.; Beckmann, J.; Bilo, H. J.; Bochud, M.; Brown, M. J.; Caulfield, M. J.; Connell, J. M.; Cook, H. T.; Cotlarciuc, I.; Davey Smith, G.; de Silva, R.; Deng, G.; Devuyst, O.; Dikkeschei, L. D.; Dimkovic, N.; Dockrell, M.; Dominiczak, A.; Ebrahim, S.; Eggermann, T.; Farrall, M.; Floege, J.; Forouhi, N. G.; Gansevoort, R. T.; Han, X.; Hedblad, B.; Homan van der Heide, J. J.; Hepkema, B. G.; Hernandez-Fuentes, M.; Hypponen, E.; Johnson, T.; de Jong, P. E.; Kleefstra, N.; Lagou, V.; Lapsley, M.; Li, Y.; Loos, R. J.; Luan, J.; Luttropp, K.; Maréchal, C.; Melander, O.; Munroe, P. B.; Nordfors, L.; Peltonen, L.; Penninx, B. W.; Perucha, E.; Pouta, A.; Roderick, P. J.; Ruokonen, A.; Samani, N. J.; Sanna, S.; Schalling, M.; Schlessinger, D.; Schlieper, G.; Seelen, M. A.; Sjögren, M.; Smit, J. H.; Snieder, H.; Soranzo, N.; Spector, T. D.; Stenvinkel, P.; Sternberg, M. J.; Swaminathan, R.; Ubink-Veltmaat, L. J.; Uda, M.; Vollenweider, P.; Wallace, C.; Waterworth, D.; Zerres, K.; Waeber, G.; Wareham, N. J.; Maxwell, P. H.; McCarthy, M. I.; Jarvelin, M. R.; Mooser, V.; Abecasis, G. R.; Lightstone, L.; Scott, J.; Navis, G.; Elliott, P.; Kooner, J. S.

    2011-01-01

    Blood pressure is a heritable trait influenced by several biological pathways and responsive to environmental stimuli. Over one billion people worldwide have hypertension (≥140 mm Hg systolic blood pressure or  ≥90 mm Hg diastolic blood pressure). Even small increments in blood pressure are

  15. Factors associated with high probability of target blood pressure non-achievement in hypertensive patients

    Directory of Open Access Journals (Sweden)

    S. P. Zhemanyuk

    2017-12-01

    Full Text Available One of the topic issue of modern cardiology is factors of target blood pressure level non-achievement clarifying due to a better understanding how we can reduce cardiovascular complications. The aim of the study is to determine the factors of poor blood pressure control using the ambulatory blood pressure monitoring parameters and adenosine 5'-diphosphate-induced platelet aggregation parameters in patients with arterial hypertension. Material and methods. The study involved 153 patients with essential hypertension (EH stage II, II degree. The ambulatory blood pressure monitoring (ABPM was performed in patients during at least two of first-line antihypertensive drugs in optimal daily doses usage by the ABPM bifunctional device (Incart, S.-P., R.F.. Platelet aggregation was carried out using light transmittance aggregation by optical analyzer (Solar, R.B. with adenosine 5'-diphosphate (Sigma-Aldrich at final concentration of 10.0 × 10-6 mol / L. The first group were inadequately controlled essential hypertensive individuals with high systolic or/and diastolic BP level according to the ABPM results, and the second one were patients with adequately controlled EH. Groups of patients were comparable in age (60.39 ± 10.74 years vs. 62.80 ± 9.63; p = 0.181, respectively. In the group of EH patients who reached the target level of blood pressure, women predominated (60% vs. 39.81%; p = 0.021, respectively. We used the binary logistic regression analysis to determine the predictors of target blood pressure level poor reaching using ABPM and platelet aggregation parameters. Results According to the univariate logistic regression analysis, the dependent factors influencing the target blood pressure level poor reaching are the average diurnal diastolic blood pressure (DBP (OR = 44.8; diurnal variability of systolic blood pressure (SBP (OR = 4.4; square index of hypertension for diurnal periods SBP (OR = 318.9; square index of hypertension for diurnal

  16. Multicomponent exercise decreases blood pressure, heart rate and double product in normotensive and hypertensive older patients with high blood pressure.

    Science.gov (United States)

    Coelho-Júnior, Hélio José; Asano, Ricardo Yukio; Gonçalvez, Ivan de Oliveira; Brietzke, Cayque; Pires, Flávio Oliveira; Aguiar, Samuel da Silva; Feriani, Daniele Jardim; Caperuto, Erico Chagas; Uchida, Marco Carlos; Rodrigues, Bruno

    2018-02-26

    The present study aimed to investigate the effects of a 6-month multicomponent exercise program on blood pressure, heart rate, and double product of uncontrolled and controlled normotensive and hypertensive older patients. The study included 183 subjects, 97 normotensives, of which 53 were controlled normotensives (CNS), and 44 uncontrolled normotensives (UNS), as well as 86 hypertensives, of which 43 were controlled hypertensives (CHS), and 43 uncontrolled hypertensives (UHS). Volunteers were recruited and blood pressure and heart rate measurements were made before and after a 6-month multicomponent exercise program. The program of physical exercise was performed twice a week for 26 weeks. The physical exercises program was based on functional and walking exercises. Exercise sessions were performed at moderate intensity. The results indicated that UHS showed a marked decrease in systolic (-8.0mmHg), diastolic (-11.1mmHg), mean (-10.1mmHg), and pulse pressures, heart rate (-6.8bpm), and double product (-1640bpmmmHg), when compared to baseline. Similarly, diastolic (-5.5mmHg) and mean arterial (-4.8mmHg) pressures were significantly decreased in UNS. Concomitantly, significant changes could be observed in the body mass index (-0.9kg/m 2 ; -1.5kg/m 2 ) and waist circumference (-3.3cm; only UHS) of UNS and UHS, which may be associated with the changes observed in blood pressure. In conclusion, the data of the present study indicate that a 6-month multicomponent exercise program may lead to significant reductions in blood pressure, heart rate, and double product of normotensive and hypertensive patients with high blood pressure values. Copyright © 2018 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  17. Tolerability of ambulatory blood pressure monitoring (ABPM) in cognitively impaired elderly.

    Science.gov (United States)

    Nesti, Nicola; Pieraccioli, Mariachiara; Mossello, Enrico; Sgrilli, Federica; Bulgaresi, Matteo; Crescioli, Elena; Biagini, Francesco; Caleri, Veronica; Tonon, Elisabetta; Cantini, Claudia; Biagini, Carlo A; Marchionni, Niccolò; Ungar, Andrea

    2014-12-01

    Recent guidelines have widened clinical indications for out-of-office blood pressure measurement, including home blood pressure monitoring and ambulatory blood pressure monitoring (ABPM), suggesting the latter as recommended method in cognitively impaired patients. There is, however, a widespread belief that ABPM could be poorly tolerated in dementia, often leading to withdraw from its use in these patients. To assess the actual tolerability of ABPM in a group of cognitively impaired elderly, affected by dementia or mild cognitive impairment (MCI). We evaluated 176 patients aged 65 + years, recruited in two different memory clinics, with a Mini Mental State Examination (MMSE) between 10 and 27. Behavioral and psychological symptoms were assessed with Neuropsychiatric Inventory (NPI). A patient was considered tolerant if able to keep the device on continuously for 24 h. The minimum number of correct measurements required was 70% of the predicted total number. 16% of patients wore the device for less than 24 h. Dividing the study population in tertiles of MMSE performance, 29% failed to tolerate the device in the lowest, 12% in the middle and 7% in the highest tertile (p ABPM proved a generally well-tolerated technique even in cognitively impaired elderly. Only a minority of subjects with poorer cognitive performances and greater behavioral symptoms did not tolerate the monitoring. Among most patients who failed to achieve the minimum number of measurements needed, the number of valid measurements was very close to the minimum required.

  18. Baseline Blood Pressure, the 2017 ACC/AHA High Blood Pressure Guidelines, and Long-Term Cardiovascular Risk in SPRINT.

    Science.gov (United States)

    Vaduganathan, Muthiah; Pareek, Manan; Qamar, Arman; Pandey, Ambarish; Olsen, Michael H; Bhatt, Deepak L

    2018-02-05

    The 2017 American College of Cardiology (ACC)/American Heart Association (AHA) guidelines include lower thresholds to define hypertension than previous guidelines. Little is known about the impact of these guideline changes in patients with or at high risk for cardiovascular disease. In this exploratory analysis using baseline blood pressure assessments in Systolic Blood Pressure Intervention Trial (SPRINT), we evaluated the prevalence and associated cardiovascular prognosis of patients newly reclassified with hypertension based on the 2017 ACC/AHA (systolic blood pressure ≥130 mm Hg or diastolic blood pressure ≥80 mm Hg) compared with the Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation and Treatment of High Blood Pressure (JNC 7) guidelines (systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg). The primary endpoint was the composite of myocardial infarction, other acute coronary syndromes, stroke, heart failure, or cardiovascular death. In 4683 patients assigned to the standard treatment arm of SPRINT, 2328 (49.7%) met hypertension thresholds by JNC 7 guidelines, and another 1424 (30.4%) were newly reclassified as having hypertension based on the 2017 ACC/AHA guidelines. Over 3.3-year median follow-up, 319 patients experienced the primary endpoint (87 of whom were newly reclassified with hypertension based on the revised guidelines). Patients with hypertension based on prior guidelines compared with those newly identified with hypertension based on the new guidelines had similar risk of the primary endpoint (2.3 [95% confidence interval {CI}, 2.0-2.7] vs 2.0 [95% CI, 1.6-2.4] events per 100 patient-years; adjusted HR, 1.10 [95% CI, 0.84-1.44]; P = .48). The 2017 ACC/AHA high blood pressure guidelines are expected to significantly increase the prevalence of patients with hypertension (perhaps to a greater extent in higher-risk patient cohorts compared with the general population) and

  19. Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.

    Science.gov (United States)

    Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong

    2018-01-01

    With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.

  20. The Role of Central Blood Pressure Monitoring in the Management of Hypertension.

    Science.gov (United States)

    Ochoa, Adrian; Patarroyo-Aponte, Gabriel; Rahman, Mahboob

    2018-04-19

    Central blood pressure is a novel predictor of cardiovascular risk that can be measured in the clinical setting using currently available technology. This paper will review current available methods of central blood pressure monitoring as well as its impact in cardiac and renal disease. Both aortic and carotid systolic blood pressure are independently associated with cardiovascular mortality and serious cardiac events. Furthermore, studies show that systolic aortic blood pressure has been shown to be superior predictor of cardiovascular as compared to brachial blood pressure. Inhibitors of the renin angiotensin axis may have a beneficial effect on central blood pressure; however, long term studies evaluating the impact of lowering central blood pressure on clinical outcomes are lacking. Central blood pressure is a good predictor of cardiovascular risk. As more studies emerge demonstrating the value of central blood pressure as a therapeutic target, it is possible that targeting central blood pressure may become an important part of the armamentarium to lower cardiovascular risk.