  1. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  2. Method of measuring blood flow by radiation

    International Nuclear Information System (INIS)

    Gildenberg, P.L.

    1977-01-01

    A method of measuring relative blood flow through at least a part of the body using penetrating radiation comprises transmitting a plurality of rays at an initial angle or initial mean angle through a planar slice of the body to define a first set of rays, transmitting a plurality of further sets of rays at angles or mean angles different from each other and from the initial angle or initial mean angle through the same planar slice of the body to define by the intersection of all such rays a two-dimensional matrix of elements of the body in the slice, measuring for each ray emerging from the body a number of over the period of time at least equal to a pulse interval representing the momentary sum of the transmissions or absorptions of the element of the body intersected by the ray, determining from the momentary signals momentary signals a difference signal representing the maximum difference between the momentary signals for each ray over the period of time, deriving sets of discrete difference signals corresponding to the sets of rays, the difference signals being indicative of the transmission or absorption of blood flowing through each element of the body in the matrix, and calculating from the difference signals resultant signals representing the transmissions or absorptions due to blood flow in the elements of the matrix. These resultant signals may be visually depicted on a cathode ray tube display, as a digital print-out, or as a photograph. 30 claims, 8 figures

  3. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  4. Noninvasive 133Xe inhalation method for cerebral blood flow measurement

    International Nuclear Information System (INIS)

    Takagi, Shigeharu; Kobatake, Keitaro; Shinohara, Yukito

    1991-01-01

    Recent development of the 133 Xe inhalation technique has made it possible to measure cerebral blood flow (CBF) noninvasively. Recording of the head curves from the frontal and temporal areas during inhalation of 133 Xe, however, is contaminated by the artifact from the air passages. A method based on Fourier transforms was reported to be able to eliminate air passage artifact (APA) effectively. However, it was pointed out that such an algorithm does not give a complete correction if the artifact seen by the head detectors differs in shape from that recorded from the airways at the mouth, which may happen when there is a slow isotope convection in the nasal and sinus cavities. The purpose of this study was to compare the CBF values calculated by the Fourier method with those by the conventional method of Obrist (VM method). Mean hemispheric gray matter flow (F 1 ) calculated by the VM method in 11 subjects, including normal volunteers and patients with various neurological diseases, was 69.2±13.2 mg/100 g brain/ min, whereas F 1 calculated by the Fourier method in the same subjects was 64.4±13.5, indicating that APA can be effectively eliminated by the Fourier method. The F 1 values calculated by the Fourier method from the frontal and temporal regions were relatively high, and closer to the F 1 values calculated by the VM method. The size of the APA was large in these regions. It was concluded that the deformed APA contaminated the results in these regions, and could not be eliminated effectively by the Fourier method. It is suggested that the shape of the head curve and the size of APA should be carefully examined to ensure that CBF data are reliable. (author)

  5. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    Science.gov (United States)

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  6. Methods for measurement of cerebral blood flow in man

    DEFF Research Database (Denmark)

    Lassen, N A

    1976-01-01

    -cerebral uptake, and insensitive both for detecting regional ischemia and regional hyperemia. The spatial resolution is also much more limited. For these reasons great caution must be exercised in interpreting the results. Methods yielding three-dimensional rCBF data will be needed in order to gain more precise...... information both on spatial localization and, especially, on ischemic areas. The most promising is computer-assisted axial tomography with freely diffusible radioactive isotopes or with x-rays using an intra-arterial injection of contrast. But, the available techniques are still too slow: in order to measure...

  7. Mass Spectrometry Method to Measure Membrane Proteins in Dried Blood Spots for the Detection of Blood Doping Practices in Sport.

    Science.gov (United States)

    Cox, Holly D; Eichner, Daniel

    2017-09-19

    The dried blood spot (DBS) matrix has significant utility for applications in the field where venous blood collection and timely shipment of labile blood samples is difficult. Unfortunately, protein measurement in DBS is hindered by high abundance proteins and matrix interference that increases with hematocrit. We developed a DBS method to enrich for membrane proteins and remove soluble proteins and matrix interference. Following a wash in a series of buffers, the membrane proteins are digested with trypsin and quantitated by parallel reaction monitoring mass spectrometry methods. The DBS method was applied to the quantification of four cell-specific cluster of differentiation (CD) proteins used to count cells by flow cytometry, band 3 (CD233), CD71, CD45, and CD41. We demonstrate that the DBS method counts low abundance cell types such as immature reticulocytes as well as high abundance cell types such as red blood cells, white blood cells, and platelets. When tested in 82 individuals, counts obtained by the DBS method demonstrated good agreement with flow cytometry and automated hematology analyzers. Importantly, the method allows longitudinal monitoring of CD protein concentration and calculation of interindividual variation which is difficult by other methods. Interindividual variation of band 3 and CD45 was low, 6 and 8%, respectively, while variation of CD41 and CD71 was higher, 18 and 78%, respectively. Longitudinal measurement of CD71 concentration in DBS over an 8-week period demonstrated intraindividual variation 17.1-38.7%. Thus, the method may allow stable longitudinal measurement of blood parameters currently monitored to detect blood doping practices.

  8. [Biocybernetic approach to the thermometric methods of blood supply measurements of periodontal tissues].

    Science.gov (United States)

    Pastusiak, J; Zakrzewski, J

    1988-11-01

    Specific biocybernetic approach to the problem of the blood supply determination of paradontium tissues by means of thermometric methods has been presented in the paper. The compartment models of the measuring procedure have been given. Dilutodynamic methology and classification has been applied. Such an approach enables to select appropriate biophysical parameters describing the state of blood supply of paradontium tissues and optimal design of transducers and measuring methods.

  9. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  10. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    International Nuclear Information System (INIS)

    McCarthy, B M; O'Flynn, B; Mathewson, A

    2011-01-01

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  11. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...

  12. /sup 3/H-dextran method for measurements of the blood volume in the rat choroid

    Energy Technology Data Exchange (ETDEWEB)

    Matsusaka, T [Osaka Prefectural Center for Adult Diseases (Japan); Morimoto, K; Kikkawa, Y

    1980-01-01

    A new method was developed using /sup 3/H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the /sup 3/H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10/sup -4/ ml per mg wet weight and 5.070 x 10/sup -4/ ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed.

  13. 3H-dextran method for measurements of the blood volume in the rat choroid

    International Nuclear Information System (INIS)

    Matsusaka, Toshihiko; Morimoto, Kazuhiro; Kikkawa, Yoshizo.

    1980-01-01

    A new method was developed using 3 H-dextran for measuring the blood volume in the choroid. Under pentobarbital-anesthesia, albino rats weighing 200 grams were perfused through the left ventricle with a 2.5 percent glutaraldehyde solution containing the radioactive dextran. The procedure allowed exchange of the choroidal blood with the 3 H-dextran solution with a simultaneous fixation of the choroid. The blood volume in the choroid was calculated from the radioactivity count, which is estimated to be 1.690 x 10 -4 ml per mg wet weight and 5.070 x 10 -4 ml per mg dry weight. Epinephrine subconjunctivally injected diminished the blood volume in the choroid by 68 percent. Pretreatment with lidocaine almost nullified the effect of epinephrine. Applicability of this method to the analytical study of the choroidal circulation is discussed. (author)

  14. Comparison of a New Cobinamide-Based Method to a Standard Laboratory Method for Measuring Cyanide in Human Blood

    Science.gov (United States)

    Swezey, Robert; Shinn, Walter; Green, Carol; Drover, David R.; Hammer, Gregory B.; Schulman, Scott R.; Zajicek, Anne; Jett, David A.; Boss, Gerry R.

    2013-01-01

    Most hospital laboratories do not measure blood cyanide concentrations, and samples must be sent to reference laboratories. A simple method is needed for measuring cyanide in hospitals. The authors previously developed a method to quantify cyanide based on the high binding affinity of the vitamin B12 analog, cobinamide, for cyanide and a major spectral change observed for cyanide-bound cobinamide. This method is now validated in human blood, and the findings include a mean inter-assay accuracy of 99.1%, precision of 8.75% and a lower limit of quantification of 3.27 µM cyanide. The method was applied to blood samples from children treated with sodium nitroprusside and it yielded measurable results in 88 of 172 samples (51%), whereas the reference laboratory yielded results in only 19 samples (11%). In all 19 samples, the cobinamide-based method also yielded measurable results. The two methods showed reasonable agreement when analyzed by linear regression, but not when analyzed by a standard error of the estimate or paired t-test. Differences in results between the two methods may be because samples were assayed at different times on different sample types. The cobinamide-based method is applicable to human blood, and can be used in hospital laboratories and emergency rooms. PMID:23653045

  15. Evaluation of three methods for hemoglobin measurement in a blood donor setting

    Directory of Open Access Journals (Sweden)

    Jacob Rosenblit

    1999-05-01

    Full Text Available CONTEXT: The hemoglobin (Hb level is the most-used parameter for screening blood donors for the presence of anemia, one of the most-used methods for measuring Hb levels is based on photometric detection of cyanmetahemoglobin, as an alternative to this technology, HemoCue has developed a photometric method based on the determination of azide metahemoglobin. OBJECTIVE: To evaluate the performance of three methods for hemoglobin (Hb determination in a blood bank setting. DESIGN: Prospective study utilizing blood samples to compare methods for Hb determination. SETTING: Hemotherapy Service of the Hospital Israelita Albert Einstein, a private institution in the tertiary health care system. SAMPLE: Serial blood samples were collected from 259 individuals during the period from March to June 1996. MAIN MEASUREMENTS: Test performances and their comparisons were assessed by the analysis of coefficients of variation (CV, linear regression and mean differences. RESULTS: The CV for the three methods were: Coulter 0.68%, Cobas 0.82% and HemoCue 0.69%. There was no difference between the mean Hb determination for the three methods (p>0.05. The Coulter and Cobas methods showed the best agreement and the HemoCue method gave a lower Hb determination when compared to both the Coulter and Cobas methods. However, pairs of methods involving the HemoCue seem to have narrower limits of agreement (± 0.78 and ± 1.02 than the Coulter and Cobas combination (± 1.13. CONCLUSION: The three methods provide good agreement for hemoglobin determination.

  16. Measurement of regional cerebral blood flow using one-point venous blood sampling and causality model. Evaluation by comparing with conventional continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Sone, Teruki; Takahashi, Yoshitake

    2008-01-01

    Optimal setting of the input function is essential for the measurement of regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP), and usually the arterial 123 I-IMP concentration (integral value) in the initial 5 min is used for this purpose. We have developed a new convenient method in which 123 I-IMP concentration in arterial blood sample is estimated from that in venous blood sample. Brain perfusion single photon emission computed tomography (SPECT) with 123 I-IMP was performed in 110 cases of central nervous system disorders. The causality was analyzed between the various parameters of SPECT data and the ratio of octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to octanol-extracted venous radioactivity concentration at 27 min after intravenous injection of 123 I-IMP (Cvoct). A high correlation was observed between the measured and estimated values of Caoct/Cvoct (r=0.856) when the following five parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and total brain radioactivity counts that were measured by a four-head gamma camera 5 min and 28 min after 123 I-IMP injection. Furthermore, the rCBF values obtained using the input parameters estimated by this method were also highly correlated with the rCBF values measured using the continuous arterial blood sampling method (r=0.912). These results suggest that this method would serve as the new, convenient and less invasive method of rCBF measurement in clinical setting. (author)

  17. Quantitative measurement of blood circulation in tests of rats using nuclear medical methods

    International Nuclear Information System (INIS)

    Ripke, R.

    1980-01-01

    The experiments show that is it is possible to quantitatively assess the blood circulation and, within limits, the germinative function of tests by measuring the impulses of an incorporated radionuclide (99-Tc-pertechnetate) using an uptake measuring instrument. This is a rapid and unbloody method to be adopted in human medicine. 'Acute tests' or pre-damaged tests can thus be exactly diagnosed. In the former case the circulation modification and in the latter the evaluation of the germinative function ability is of main interest. The most important measuring criterion is the 15-minute-uptake U; it represents the blood circulation in the tests measured. The germinative function ability is evaluated on the basis of the accumulation activity Nsub(max). (orig./MG) [de

  18. Indirect viscosimetric method is less accurate than ektacytometry for the measurement of red blood cell deformability.

    Science.gov (United States)

    Vent-Schmidt, Jens; Waltz, Xavier; Pichon, Aurélien; Hardy-Dessources, Marie-Dominique; Romana, Marc; Connes, Philippe

    2015-01-01

    The aim of this study was to test the accuracy of viscosimetric method to estimate the red blood cell (RBC) deformability properties. Thirty-three subjects were enrolled in this study: 6 healthy subjects (AA), 11 patients with sickle cell-hemoglobin C disease (SC) and 16 patients with sickle cell anemia (SS). Two methods were used to assess RBC deformability: 1) indirect viscosimetric method and 2) ektacytometry. The indirect viscosimetric method was based on the Dintenfass equation where blood viscosity, plasma viscosity and hematocrit are measured and used to calculate an index of RBC rigidity (Tk index). The RBC deformability/rigidity of the three groups was compared using the two methods. Tk index was not different between SS and SC patients and the two groups had higher values than AA group. When ektacytometry was used, RBC deformability was lower in SS and SC groups compared to the AA group and SS and SC patients were different. Although the two measures of RBC deformability were correlated, the association was not very high. Bland and Altman analysis demonstrated a 3.25 bias suggesting a slight difference between the two methods. In addition, the limit of agreement represented 28% (>15%) of the mean values of RBC deformability, showing no interchangeability between the two methods. In conclusion, measuring RBC deformability by indirect viscosimetry is less accurate than by ektacytometry, which is considered the gold standard.

  19. Comparative study of methods for blood flow measurement within transverse sinuses by using MR

    International Nuclear Information System (INIS)

    Gao Gejun; Feng Xiaoyuan; Yang Bojie; Geng Daoying

    2003-01-01

    Objective: To assess the accuracy of two-dimensional phase contrast (2D-PC) MR method for blood flow measurement within transverse sinuses by comparing this method with cine phase contrast (cine-PC) MR and Doppler in volunteers and patients. Methods: (1) A total of 12 transverse sinuses were examined in 8 healthy volunteers. 2D-PC MR and cine-PC MR were used respectively to measure the transverse area of flow, the flow velocities, and the volumetric flow rates in the same position in every transverse sinus. Paired t-test was used for comparison between the results determined by 2D-PC MR and that determined by cine-PC MR. (2) A total of 6 transverse sinuses were examined in 5 patients who needed operation. 2D-PC MR was used to determine the blood flow velocity of transverse sinus before operation, and Doppler was used to determine the blood flow velocity of the same transverse sinus during operation. The linear regression analysis was used for statistical analysis. Results: (1) Statistical analysis indicated that there were no significant difference among the transverse area of flow (t = -1.106, P = 0.293), the flow velocities (t = 0.262, P = 0.798), and the volumetric flow rates (t = 0.439, P = 0.669) measured by using 2D-PC MR and cine PC MR, respectively. (2) The correlation between flow velocities determined by 2D-PC MR imaging before operation and that determined by Doppler during operation was in excellent agreement (Y-circumflex = 1.303 x + 0.62, r 2 = 0.88). Conclusion: 2D-PC MR may be a practical convenient method for blood flow measurement within transverse sinuses system

  20. A study on measurement of the regional cerebral blood flow using autoradiographic method in moyamoya disease

    International Nuclear Information System (INIS)

    Sasaki, Tomohiro; Kiya, Katsuzo; Yuki, Kiyoshi; Kawamoto, Hitoshi; Mizoue, Tatsuya; Kiura, Yoshihiro; Uozumi, Tohru; Ikawa, Fusao

    1997-01-01

    Development of Autoradiographic method (ARG) has provided measurement of cerebral blood flow in moyamoya disease. We evaluate a cerebral vasodilatory capacity (CVC) for moyamoya disease using ARG method. We used 5 patients with moyamoya disease as a candidate for measurement of the cerebral blood flow (CBF) who admitted to Hiroshima Prefectural Hospital during the past one year. There were 3 patients in an adult age and 2 patients in a young age. We tried to measure the regional CBF (rCBF) using ARG method which was a easy way to estimate the rCBF on SPECT. The CVC was calculated from the difference of the rCBF between resting SPECT and Diamox-loading SPECT. Results were as follows; Reactivity of cerebral vessels to CO 2 loading and CVC weakened in moyamoya disease. The rCBF and CVC in the territories of anterior and middle cerebral arteries reduced in comparison with those in the area supplied by the posterior cerebral artery. The CVC at the treated side with surgical reconstruction recovered somewhat in an adult type. From these results, measurement of CBF using ARG method seems to be useful for evaluation of the CVC in moyamoya disease. (author)

  1. The cerebral blood flow measurement without absolute input function value for PET O-15 injection method

    International Nuclear Information System (INIS)

    Matsuda, Tadashige

    2004-01-01

    This paper shows the method of the measurement for the region of interest's (ROI's) cerebral blood flow (CBF) using PET data and the input function without the absolute density value of the radio activity. The value of the input function and the output function are fixed from the clinical data by regression analysis. The input function and the output function are transformed by the Fourier transform. The transfer function of the differential equation of the compartment model is got by these Fourier transforms. The CBF can be estimated by the transfer function regression analysis. Results are compared between the proposal and conventional methods. (author)

  2. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  3. Microalbuminuria Measured by three Different Methods, Blood Pressure and Cardiovascular Risk Factors in Elderly Swedish Males

    Directory of Open Access Journals (Sweden)

    Gösta Florvall

    2008-01-01

    Full Text Available Microalbuminuria is associated with hypertension and is a strong risk factor for subsequent chronic disease, both renal and coronary heart disease (CHD, Presently there are several methods available for measurement of microalbuminuria. The aim of this study was to evaluate if the three different methods gave similar information or if one of the assays were superior to the others. Blood pressure, inflammatory markers and cardiovascular mortality and morbidity were correlated with urine albumin analysed with a point-of-care testing (POCT instrument, nephelometric determination of albumin and albumin/creatinine ratio in elderly males. The study population consisted of 103 diabetic and 603 nondiabetic males (age 77 years in a cross-sectional study. We analyzed urine albumin with a HemoCue® Urine Albumin POCT instrument and a ProSpec® nephelometer and albumin/creatinine ratio. There were strong correlations between both systolic and diastolic blood pressure and all three urine albumin methods (p < 0.0001. There were also significant correlations between the different urine albumin measurements and serum amyloid A component, high-sensitivity C-reactive protein and interleukin-6. The three different urine albumin methods studied provided similar information in relation to cardiovascular disease. There was a strong correlation between systolic and diastolic blood pressure and microalbuminuria in both the whole study population and in nondiabetic males emphasizing the role of hypertension in glomerular damage. The good correlation between the studied urine albumin measurements show that all three methods can be used for monitoring urine albumin excretion.

  4. Light scattering method to measure red blood cell aggregation during incubation

    Science.gov (United States)

    Grzegorzewski, B.; Szołna-Chodór, A.; Baryła, J.; DreŻek, D.

    2018-01-01

    Red blood cell (RBC) aggregation can be observed both in vivo as well as in vitro. This process is a cause of alterations of blood flow in microvascular network. Enhanced RBC aggregation makes oxygen and nutrients delivery difficult. Measurements of RBC aggregation usually give a description of the process for a sample where the state of a solution and cells is well-defined and the system reached an equilibrium. Incubation of RBCs in various solutions is frequently used to study the effects of the solutions on the RBC aggregation. The aggregation parameters are compared before and after incubation while the detailed changes of the parameters during incubation remain unknown. In this paper we have proposed a method to measure red blood cell aggregation during incubation based on the well-known technique where backscattered light is used to assess the parameters of the RBC aggregation. Couette system consisting of two cylinders is adopted in the method. The incubation is observed in the Couette system. In the proposed method following sequence of rotations is adapted. Two minutes rotation is followed by two minutes stop. In this way we have obtained a time series of back scattered intensity consisting of signals respective for disaggregation and aggregation. It is shown that the temporal changes of the intensity manifest changes of RBC aggregation during incubation. To show the ability of the method to assess the effect of incubation time on RBC aggregation the results are shown for solutions that cause an increase of RBC aggregation as well as for the case where the aggregation is decreased.

  5. Cerebral blood flow measurement using 123I-IMP graph plot method with SPECT. Comparison with autoradiography method

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kamitani, Hideki; Ishibashi, Minako; Ito, Satoru; Ogawa, Toshihide

    2011-01-01

    The purpose of this study was to evaluate quantification of cerebral blood flow (CBF) values using 123 I-iodoamphetamine (IMP) graph plot (GP) method with single photon emission computed tomography (SPECT), compared with autoradiography (ARG) method. IMP-SPECT by GP combined with ARG method at rest was performed in 40 patients to determine the equation of linear regression for GP method in our institution. In addition, we compared regional CBF (rCBF) values at rest between GP and ARG methods in 10 other patients. Among all 50 patients, acetazolamide (ACZ)-challenged SPECT by GP combined with ARG method using 2-day protocol was performed in 10 patients. We also compared the rCBF values after ACZ challenge between GP and ARG methods in these 10 patients. The equation of linear regression for GP method in our institution was y=1.945x+20.36 (R 2 =0.586, P 2 =0.624, P 2 =0.150, P<0.001). IMP-SPECT by GP method at rest is useful to measure reliable rCBF values without arterial blood sampling, although we need pay attention to interpret the result of 2-day protocol ACZ-challenged SPECT by GP method. (author)

  6. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  7. Blood pressure measurement method and inter-arm differences: a meta-analysis.

    Science.gov (United States)

    Verberk, Willem J; Kessels, Alfons G H; Thien, Theo

    2011-11-01

    Screening for inter-arm difference (IAD) of blood pressure (BP) at each first visit is recommended by numerous guidelines whereas it is unclear whether the method by which IAD is measured has significant influence on the IAD value. A systematic review is made of the studies reporting on double-arm measurements and the association of IAD with procedure characteristics (Medline/PubMed, Embase, and Cochrane Library). The mean absolute IAD was 5.4 ± 1.7 and 3.6 ± 1.2 mm Hg for systolic and diastolic BP, respectively. Of all subjects 14% had a systolic IAD ≥10 mm Hg, 4% a systolic IAD ≥20 mm Hg, and 7% a diastolic IAD ≥10 mm Hg. The relative risk (RR) of obtaining a systolic IAD ≥10 and 20 mm Hg and a diastolic IAD ≥10 mm Hg is higher when measuring sequentially instead of simultaneously (2.2 (95% CI: 1.4-3.6), P arms, with one or two automatic devices and multiple readings should be taken.

  8. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  9. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    Science.gov (United States)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady

  10. A simple and efficient method for measuring the uptake of radiolabelled compounds by leukocytes in whole blood

    International Nuclear Information System (INIS)

    Pauly, J.L.; Schuller, M.G.; Germain, M.J.

    1977-01-01

    A liquid scintillation counting procedure is described for measuring the uptake of radiolabelled compounds by leukocytes in large or small volumes of whole blood. Color and chemical quenching as well as other technical difficulties noted previously by investigators attempting to process whole blood were eliminated by selectively disrupting the erythrocytes. This was readily accomplished by washing the blood with 3% acetic acid. After bleaching the leukocyte pellet with hydrogen peroxide, the sample was prepared for counting using methods in which the cells were dissolved or oxidized. Examples demonstrating the utility of the proposed technique are presented in which DNA, RNA and protein synthesis of leukocytes from patients with uncontrolled leukemia were measured by the uptake of tritiated thymidine, uridine and leucine, respectively. Also noted is the feasibility of employing a multiple automated sample harvester and whole blood microcultures. The advantages realised by these methods and their potential clinical and experimental utility are discussed. (author)

  11. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi; Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-01-01

    A noninvasive microsphere method using N-isopropyl-p-( 123 I)iodoamphetamine ( 123 I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  12. Modification of a two blood sample method used for measurement of GFR with 99mTc-DTPA.

    Science.gov (United States)

    Surma, Marian J; Płachcińska, Anna; Kuśmierek, Jacek

    2018-01-01

    Measurements of GFR may be performed with a slope/intercept method (S/I), using only two blood samples taken in strictly defined time points. The aim of the study was to modify this method in order to extend time intervals suitable for blood sampling. Modification was based on a variation of a Russel et al. model parameter, selection of time intervals suitable for blood sampling and assessment of uncertainty of calculated results. Archived values of GFR measurements of 169 patients with different renal function, from 5.5 to 179 mL/min, calculated with a multiple blood sample method were used. Concentrations of a radiopharmaceutical in consecutive minutes, from 60th to 190th after injection, were calculated theoretically, using archived parameters of biexponential functions describing a decrease in 99mTc-DTPA concentration in blood plasma with time. These values, together with injected activities, were treated as measurements and used for S/I clearance calculations. Next, values of S/I clearance were compared with the multiple blood sample method in order to calculate suitable values of exponent present in a Russel's model, for every combination of two blood sampling time points. A model was considered accurately fitted to measured values when SEE ≤ 3.6 mL/min. Assessments of uncertainty of obtained results were based on law of error superposition, taking into account mean square prediction error and also errors introduced by pipetting, time measurement and stochastic radioactive decay. The accepted criteria resulted in extension of time intervals suitable for blood sampling to: between 60 and 90 minutes after injection for the first sample and between 150 and 180 minutes for the second sample. Uncertainty of results was assessed as between 4 mL/min for GFR = 5-10 mL/min and 8 mL/min for GFR = 180 mL/min. Time intervals accepted for blood sampling fully satisfy nuclear medicine staff and ensure proper determination of GFR. Uncertainty of results is entirely

  13. An intravenous isotope method for measuring regional cerebral blood flow (rCBF) and volume (rCBV)

    International Nuclear Information System (INIS)

    Kuikka, J.; Ahonen, A.; Koivula, A.; Kallanranta, T.; Laitinen, J.

    1977-01-01

    The regional cerebal blood flow (rCBF), initial slope index (ISI), transfer time (t - sub(h)) and volume (rCBV) were measured simultaneously in 43 hospital patients using a 133 Xe intravenous injection method and quantitative dynamic 99 Tcsup(m) brain scintigraphy. The measurements were made with a gamma camera and the data processing interfaced with a small digital computer. The mean values and standard deviations were obtained from 50 control hemispheres standardized to the age of 40 years. Good agreement was found between the blood flow values determined from the intra-arterial and intravenous injection techniques. (author)

  14. Portable dynamic light scattering instrument and method for the measurement of blood platelet suspensions

    International Nuclear Information System (INIS)

    Maurer-Spurej, Elisabeth; Brown, Keddie; Labrie, Audrey; Marziali, Andre; Glatter, Otto

    2006-01-01

    No routine test exists to determine the quality of blood platelet transfusions although every year millions of patients require platelet transfusions to survive cancer chemotherapy, surgery or trauma. A new, portable dynamic light scattering instrument is described that is suitable for the measurement of turbid solutions of large particles under temperature-controlled conditions. The challenges of small sample size, short light path through the sample and accurate temperature control have been solved with a specially designed temperature-controlled sample holder for small diameter, disposable capillaries. Efficient heating and cooling is achieved with Peltier elements in direct contact with the sample capillary. Focusing optical fibres are used for light delivery and collection of scattered light. The practical use of this new technique was shown by the reproducible measurement of latex microspheres and the temperature-induced morphological changes of human blood platelets. The measured parameters for platelet transfusions are platelet size, number of platelet-derived microparticles and the response of platelets to temperature changes. This three-dimensional analysis provides a high degree of confidence for the determination of platelet quality. The experimental data are compared to a matrix and facilitate automated, unbiased quality testing

  15. Headspace gas chromatographic method for the measurement of difluoroethane in blood.

    Science.gov (United States)

    Broussard, L A; Broussard, A; Pittman, T; Lafferty, D; Presley, L

    2001-01-01

    To develop a gas chromatographic assay for the analysis of difluoroethane, a volatile substance, in blood and to determine assay characteristics including linearity, limit of quantitation, precision, and specificity. Referral toxicology laboratory Difluoroethane, a colorless, odorless, highly flammable gas used as a refrigerant blend component and aerosol propellant, may be abused via inhalation. A headspace gas chromatographic procedure for the identification and quantitation of difluoroethane in blood is presented. A methanolic stock standard prepared from pure gaseous difluoroethane was used to prepare whole blood calibrators. Quantitation of difluoroethane was performed using a six-point calibration curve and an internal standard of 1-propanol. The assay is linear from 0 to 115 mg/L including a low calibrator at 4 mg/L, the limit of quantitation. Within-run coefficients of variation at mean concentrations of 13.8 mg/L and 38.5 mg/L were 5.8% and 6.8% respectively. Between-run coefficients of variation at mean concentrations of 15.9 mg/L and 45.7 mg/L were 13.4% and 9.8% respectively. Several volatile substances were tested as potential interfering compounds with propane having a retention time identical to that of difluoroethane. This method requires minimal sample preparation, is rapid and reproducible, can be modified for the quantitation of other volatiles, and could be automated using an automatic sampler/injector system.

  16. A statistical method to calculate blood contamination in the measurement of salivary hormones in healthy women.

    Science.gov (United States)

    Behr, Guilherme A; Patel, Jay P; Coote, Marg; Moreira, Jose C F; Gelain, Daniel P; Steiner, Meir; Frey, Benicio N

    2017-05-01

    Previous studies have reported that salivary concentrations of certain hormones correlate with their respective serum levels. However, most of these studies did not control for potential blood contamination in saliva. In the present study we developed a statistical method to test the amount of blood contamination that needs to be avoided in saliva samples for the following hormones: cortisol, estradiol, progesterone, testosterone and oxytocin. Saliva and serum samples were collected from 38 healthy, medication-free women (mean age=33.8±7.3yr.; range=19-45). Serum and salivary hormonal levels and the amount of transferrin in saliva samples were determined using enzyme immunoassays. Salivary transferrin levels did not correlate with salivary cortisol or estradiol (up to 3mg/dl), but they were positively correlated with salivary testosterone, progesterone and oxytocin (phormones in order to determine the level of blood contamination that might affect specific hormonal salivary concentrations. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. Oscillometric and auscultatory blood pressure measurement methods in children: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncombe, Stephanie L; Voss, Christine; Harris, Kevin C

    2017-02-01

    The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free alternative to BP measurements by auscultation, whereas oscillometric (automated) devices are increasingly becoming the norm in clinical practice due to their ease of use. The aim of this systematic review and meta-analysis was to investigate the accuracy of oscillometric and aneroid BP devices compared with the mercury sphygmomanometer for the measurement of BP in children. We systematically searched four electronic databases (MEDLINE, Embase, CINAHL, and Web of Science) and relevant journals for eligible articles published before 30 July 2015. We screened 1415 articles, and two authors independently reviewed 92 full-text articles. We included 29 articles (38 studies) with 26 879 children. Random-effects model meta-analyses revealed that oscillometric devices yield higher measurements of SBP than auscultation with a mercury sphygmomanometer (pooled effect estimate 2.53 mmHg; 95% CI 0.57-4.50; P devices and found comparable results. Oscillometric devices may serve as a suitable alternative to auscultation for initial BP screening in the pediatric population.

  18. A method for estimating the accuracy of measurements of optical characteristics of the nuclei of blood cells in the diagnosis of acute leukemia

    Science.gov (United States)

    Polyakov, E. V.; Nikitaev, V. G.

    2017-01-01

    The work is devoted to investigation of the random component of the measurement error of the nuclei structure characteristics, which are used in the method of structural elements to measure the differences of blood cells of different types. This method is realized in information-measuring system of the analysis of micropreparations of blood cells in the diagnosis of acute leukemia and its variants.

  19. Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    International Nuclear Information System (INIS)

    Hachiya, Takenori; Inugami, Atsushi; Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using 99m Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99m Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  20. Regional cerebral blood flow measurements using noninvasive 133Xe clearance method in children

    International Nuclear Information System (INIS)

    Nishimoto, Hiroshi; Maeda, Koji; Kagawa, Yukihide; Morozumi, Kunihiko; Hashimoto, Manami; Tsubokawa, Takashi.

    1985-01-01

    The noninvasive 133-Xe clearance method of estimating rCBF has been widely used in adult clinical studies. It is safe, noninvasive and reproducible, and has provided valuable insight into adult cerebrovascular pathophysiology. However, in children, this technique has not been used to measure rCBF for some fundamental problems. This study was performed to clarify these fundamental problems for applications of noninvasive 133-Xe clearance technique to children. The results showed that three fundamental problems concerning; (1) volume of dead spaces in airway circuits of the system, (2) increasing of look-through phenomenon and (3) correction methods for recirculated 133-Xe and airway artifacts to estimate rCBF are important for applications to children. These problems should be improved to measure as correct rCBF in children as in adults. (author)

  1. Methods of measurement of myocardial blood flow in patients: a critical review

    International Nuclear Information System (INIS)

    Marcus, M.L.; Wilson, R.F.; White, C.W.

    1987-01-01

    During the past decade, major progress has been made in the evolution of technology directed toward the accurate measurement of regional myocardial perfusion in patients. The deficiencies of some of the older methods (thermodilution and gas clearance) are better appreciated and improved approaches (Doppler catheters, positron-emission tomography, and digital subtraction angiography) have been developed. The new approaches should play a major role in research and for most applications the older methods will gradually be replaced. Efforts to bring these new methods to community hospitals and practicing cardiologists should be stimulated. Doppler catheters, positron-emission tomography, and digital-subtraction angiography are commercially available and Doppler catheters and digital-subtraction angiography could be easily incorporated into routine cardiac catheterization procedures. The Doppler catheter is the most inexpensive and probably the simplest to apply. In our opinion, routine measurements of coronary flow reserve will significantly improve the care of patients with coronary obstructive disease and other diseases that impair myocardial perfusion. If coronary reserve measurements are used frequently, patient selection for coronary angioplasty and bypass surgery will no longer depend entirely on visual assessment of percent diameter stenosis, a very poor criterion in many situations. Also, patients with chest pain syndromes, normal coronary vessels, and impaired coronary reserve will be identified and perhaps some effective treatment for this condition will be devised. 77 references

  2. Improvement of the 99mTc-ECD brain uptake ratio (BUR) method for measurement of cerebral blood flow

    International Nuclear Information System (INIS)

    Ito, Shigeki; Takaki, Akihiro; Inoue, Shinya

    2012-01-01

    The brain uptake ratio (BUR) method for the 99m Tc-ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT), a non-invasive measurement method of regional cerebral blood flow (rCBF), has been used in clinical practice in Japan, because it is simple to use. However, the accuracy of this method is limited, as it has problems in the determination of input function and the regression equation. The purpose of this study is to improve the BUR method by reconstructing the determination process of the input function and regression equation based on measurement of the rCBF by H 2 15 O positron emission tomography (PET). The input function was obtained by setting the region of interest on the ascending aorta instead of the aortic arch. The 3DSRT algorithm was used to obtain the anatomically standardized rCBF, and developed a semi-automatic analyzing software using C++ in order to stabilize the repeatability of the improved BUR (IBUR) method. The regression equation for the IBUR method was obtained by the H 2 15 O PET rCBFs in 15 patients with the arterial blood sampling method. All the measurements in this study were performed with the patient in the resting state. A good correlation was observed between the rCBF values measured by H 2 15 O PET and the regional BURs measured by the IBUR method (r=0.86, p 2 15 O PET. This finding indicates the potential clinical usefulness of this method. (author)

  3. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  4. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  6. Quantitative Assessment of Blood Pressure Measurement Accuracy and Variability from Visual Auscultation Method by Observers without Receiving Medical Training

    Science.gov (United States)

    Feng, Yong; Chen, Aiqing

    2017-01-01

    This study aimed to quantify blood pressure (BP) measurement accuracy and variability with different techniques. Thirty video clips of BP recordings from the BHS training database were converted to Korotkoff sound waveforms. Ten observers without receiving medical training were asked to determine BPs using (a) traditional manual auscultatory method and (b) visual auscultation method by visualizing the Korotkoff sound waveform, which was repeated three times on different days. The measurement error was calculated against the reference answers, and the measurement variability was calculated from the SD of the three repeats. Statistical analysis showed that, in comparison with the auscultatory method, visual method significantly reduced overall variability from 2.2 to 1.1 mmHg for SBP and from 1.9 to 0.9 mmHg for DBP (both p auscultation methods). In conclusion, the visual auscultation method had the ability to achieve an acceptable degree of BP measurement accuracy, with smaller variability in comparison with the traditional auscultatory method. PMID:29423405

  7. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  8. Measurement of placental blood flow by the sup(113m)In accumulation method

    International Nuclear Information System (INIS)

    Olkkonen, H.; Suonio, S.

    1976-01-01

    The present work introduces the use of isotope In-113m in the assessment of placental blood flow. It is almost completely bound to plasma transferrin. Owing to this and its short half-life, In-113m introduces considerably slighter radiation dose to the fetus than Tc-99m. A typical tracer appearance curve is given and the In accumulation index is calculated. (M.S.)

  9. Effect of attenuation by the cranium on quantitative SPECT measurements of cerebral blood flow and a correction method

    International Nuclear Information System (INIS)

    Iwase, Mikio; Kurono, Kenji; Iida, Akihiko.

    1998-01-01

    Attenuation correction for cerebral blood flow SPECT image reconstruction is usually performed by considering the head as a whole to be equivalent to water, and the effects of differences in attenuation between subjects produced by the cranium have not been taken into account. We determined the differences in attenuation between subjects and assessed a method of correcting quantitative cerebral blood flow values. Attenuations by head on the right and left sides were measured before intravenous injection of 123 I-IMP, and water-converted diameters of both sides (Ta) were calculated from the measurements obtained. After acquiring SPECT images, attenuation correction was conducted according to the method of Sorenson, and images were reconstructed. The diameters of the right and left sides in the same position as the Ta (Tt) were calculated from the contours determined by threshold values. Using Ts given by 2 Ts=Ta-Tt, the correction factor λ=exp(μ 1 Ts) was calculated and multiplied as the correction factor when rCBF was determined. The results revealed significant differences between Tt and Ta. Although no gender differences were observed in Tt, they were seen in both Ta and Ts. Thus, interindividual differences in attenuation by the cranium were found to have an influence that cannot be ignored. Inter-subject correlation is needed to obtain accurate quantitative values. (author)

  10. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  11. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  12. Effect of prewarming the forearm on the measurement of regional cerebral blood flow with one-point venous sampling by autoradiography method

    International Nuclear Information System (INIS)

    Itoh, Youko H.; Kurabe, Teruhisa; Kazaoka, Yoshiaki; Ishiguchi, Tsuneo; Kawashima, Sadao

    2004-01-01

    Autoradiography (ARG) using 123 I-iodoamphetamine ( 123 I-IMP) is widely performed as an efficient method of measuring local cerebral blood flow. Recently, ARG by a single collection of venous blood has been appreciated as a simple method. In this study, we investigated the effect of warming of the site for collecting venous blood (forearm). The coefficient of correlation of the local cerebral blood flow value obtained from arterial and venous blood samples was 0.766 (p<0.05) in the group without warming (38 patients). The coefficient of correlation similarly obtained in the group with warming (53 patients) was 0.908 (p<0.05). The difference in the correlation efficient was significant (p<0.05) between the two groups. From these results it was concluded that warming the blood-collecting site decreased the difference between the arterial and venous radioactive concentrations and increased the precision of the test. (author)

  13. Early changes in blood flow of the mouse skin after irradiation as measured by the 133Xe clearance method

    International Nuclear Information System (INIS)

    Tsujii, Hirohiko; Irie, Goro

    1983-01-01

    The early effects of radiation on the local blood flow in the skin of mice were evaluated by measuring the local clearance rate of 133 Xe after its subcutaneous injection; this was done at four to five weeks after irradiation during the animals' normal resting conditions. The fractionation schedules employed were single fractions, two fractions in 15 days and four fractions in 15 days. The dose effect curves with these schedules showed a two-component pattern. There was a uniform reduction in flood flow after 10 to 30 Gy, and a steady increase in flood flow after doses more than 40 Gy. The blood flow after higher-fractionated doses was always lower than less-fractionated doses. It was considered that radiation doses causing higher severity of acute skin reactions might have predominated a degree of acute vasodilatation over fibrotic changes, thus resulting in increased blood flow. A steady increase in early blood flow was observed with increasing severity of acute skin reactions, but the early blood flow was not a good indicator for predicting late skin reactions, except for a severe leg deformity which was accompanied with a significant increase in early blood flow. (author)

  14. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  15. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  16. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  17. Effects of antipsoriatic treatment on cutaneous blood flow in psoriasis measured by 133Xe washout method and laser Doppler velocimetry

    International Nuclear Information System (INIS)

    Klemp, P.; Staberg, B.

    1985-01-01

    In 8 patients with psoriasis vulgaris, the cutaneous blood flow (CBF) was measured simultaneously in both involved and uninvolved psoriatic skin before (i.e., on the first day of hospitalization) and on the 3rd, 7th, 14th, and 28th days of treatment with tar. The 133 Xe washout method was used after epicutaneous labeling and compared to the laser Doppler velocimetry (LDV) technique. Control experiments were performed in 10 normal individuals. Before treatment the mean CBF in involved psoriatic skin was 62.6 +/- 18.7 SD ml X (100 g X min)-1, which is significantly higher than CBF of uninvolved skin in psoriatic patients, 9.5 +/- 4.0 SD ml X (100 g X min)-1, (p less than 0.01) and is 13.6 times higher than CBF in the normal individuals (p less than 0.01). Fifty hours following onset of treatment (i.e., after only 2 applications of tar), mean CBF of the involved psoriatic skin had decreased significantly to 35.0 +/- 13.9 SD ml X (100 g X min)-1, (p less than 0.01), which was not statistically different from the CBF on the 7th day. During the following weeks, the CBF in involved psoriatic skin decreased at a more moderate rate than that observed during the first week and was 15.0 +/- 6.1 SD ml X (100 g X min)-1 on the 28th day. This value is not significantly different from the CBF of uninvolved skin in these patients. At the end of treatment, the CBF of the uninvolved skin had decreased significantly (p less than 0.05) in all the patients to values similar to those observed in the skin of normal individuals. A parallel decline was observed in a clinical psoriatic score index; however, it is not known whether the observed decrease in CBF was preceded or succeeded by the clinical improvement

  18. A simple and rapid method for measurement of 10B-para-boronophenylalanine in the blood for boron neutron capture therapy using fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Kashino, Genro; Fukutani, Satoshi; Suzuki, Minoru

    2009-01-01

    10 B deriving from 10 B-para-boronophenylalanine (BPA) and 10 B-borocaptate sodium (BSH) have been detected in blood samples of patients undergoing boron neutron capture therapy (BNCT) using prompt gamma ray spectrometer or Inductively Coupled Plasma (ICP) method, respectively. However, the concentration of each compound cannot be ascertained because boron atoms in both molecules are the target in these assays. Here, we propose a simple and rapid method to measure only BPA by detecting fluorescence based on the characteristics of phenylalanine. 10 B concentrations of blood samples from human or mice were estimated by the fluorescence intensities at 275 nm of a BPA excited by light of wavelength 257 nm using a fluorescence spectrophotometer. The relationship between fluorescence to increased BPA concentration showed a positive linear correlation. Moreover, we established an adequate condition for BPA measurement in blood samples containing BPA, and the estimated 10 B concentrations of blood samples derived from BPA treated mice were similar between the values obtained by our method and those by ICP method. This new assay will be useful to estimate BPA concentration in blood samples obtained from patients undergoing BNCT especially in a combination use of BSH and BPA. (author)

  19. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  20. Development of quantification analysis software for measuring regional cerebral blood flow by the modified split-dose method with 123I-IMP before and after acetazolamide loading

    International Nuclear Information System (INIS)

    Nagaki, Akio; Kobara, Kouichi; Matsutomo, Norikazu

    2003-01-01

    We developed a quantification analysis software program for measuring regional cerebral blood flow (rCBF) at rest and under acetazolamide (ACZ) stress by the modified split-dose (MSD) method with iodine-123 N-isopropyl-p-iodoamphetamine (IMP) and compared the rCBF values measured by the MSD method and by the split dose 123 I-IMP SPECT (SD) method requiring one continuous withdrawal of arterial blood. Since the MSD method allows the input of two arterial blood sampling parameter values, the background subtraction procedure for obtaining ACZ-induced images in the MSD method is not identical to the procedure in the SD method. With our software program for rCBF quantification, the resting rCBF values determined by the MSD method were closely correlated with the values measured by the SD method (r=0.94), and there was also a good correlation between the ACZ-induced rCBF values obtained by the MSD method and by the SD method (r=0.81). The increase in rCBF under ACZ stress was estimated to be approximately 26% by the SD method and 38% by the MSD method, suggesting that the MSD method tends to overestimate the increase in rCBF under ACZ stress in comparison with the SD method, but the variability of the rCBF values at rest and during ACZ stress analyzed by the MSD method was smaller than the variability with the SD method. Further clinical studies are required to validate our rCBF quantification analysis program for the MSD method. (author)

  1. Tomographic measurement of cerebral blood flow by the /sup 68/Ga-labelled-microsphere and continuous-C/sup 15/O/sub 2/-inhalation methods

    Energy Technology Data Exchange (ETDEWEB)

    Steinling, M.; Baron, J.C.; Maziere, B.; Loc' h, C.; Lasjaunias, P.; Canabis, E.A.; Guillon, B.

    1985-05-01

    The measurement of cerebral blood flow (CBF) by continuous C/sup 15/O/sub 2/ inhalation has only been validated previously by indirect experimental protocols. In the present study using baboons, these measurements were compared directly with those obtained by injection of /sup 68/Ga-labelled serum-albumin microspheres in the left cardiac ventricle. Using a modified labelling technique, no elution of /sup 68/Ga occurred in vivo. Both methods provided similar regional CBF values, which could be described by a significant linear correlation (CBFsub(CO2) = 0.82 CBFsub(microspheres)+5.7; P < 0.001). The validity of the labelled-microsphere-injection method was verified. The feasibility of stable in vivo labelling of /sup 68/Ga to serum-albumin microspheres provides a reference method for organ blood-flow measurements using positron-emission tomography.

  2. Tomographic measurement of cerebral blood flow by the /sup 68/Ga-labelled-microsphere and continuous-C/sup 15/O/sub 2/-inhalation methods

    Energy Technology Data Exchange (ETDEWEB)

    Steinling, M.; Baron, J.C.; Maziere, B.; Loc' h, C.; Lasjaunias, P.; Canabis, E.A.; Guillon, B.

    1985-07-01

    The measurement of cerebral blood flow (CBF) by continuous C/sup 15/O/sub 2/ inhalation has only been validated previously by indirect experimental protocols. In the present study using baboons, these measurements were compared directly with those obtained by injection of /sup 68/Ga-labelled serum-albumin microspheres in the left cardiac ventricle. Using a modified labelling technique, no elution of /sup 68/Ga occurred in vivo. Both methods provided similar regional CBF values, which could be described by a significant linear correlation (CBFsub(CO2)=0.82 CBFsub(microspheres)+5.7; P < 0.001). The validity of the labelled-microsphere-injection method was verified. The feasibility of stable in vivo labelling of /sup 68/Ga to serum-albumin microspheres provides a reference method for organ blood-flow measurements using positron-emission tomography.

  3. Double-radionuclide autoradiographic method using N-isopropyl-iodoamphetamine for sequential measurements of local cerebral blood flow

    International Nuclear Information System (INIS)

    Obrenovitch, T.P.; Clayton, C.B.; Strong, A.J.

    1987-01-01

    A double-radionuclide autoradiographic method has been assessed for sequential determinations of local CBF (LCBF). It is based on two successive intravascular injections of N-isopropyl-p-iodoamphetamine (IMP) labelled with different radionuclides, whose concentrations can later be differentiated in the same tissue section using double-radionuclide autoradiography. Previous studies suggested that the distribution of IMP, up to 30 min after its administration, still represents LCBFs. Our data indicate that, provided the tracer is injected directly into the left ventricle, there is little back diffusion from normal brain to blood under physiological conditions for at least 35 min following the tracer injection and an injection of unlabelled IMP, in a dose larger than that used for blood flow determination, does not displace any labelled IMP previously taken up by the brain, nor does it displace any labelled IMP previously accumulated in the lung that would lead to secondary brain uptake. On the basis of these results, we conclude that sequential autoradiographic determinations of LCBF using IMP labelled with different radionuclides is possible. This is a promising experimental method for the simultaneous investigation of changes in LCBF in several CNS structures

  4. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and99mTc-tetrofosmin: Method and validation

    OpenAIRE

    Shrestha, U; Sciammarella, M; Alhassen, F; Yeghiazarians, Y; Ellin, J; Verdin, E; Boyle, A; Seo, Y; Botvinick, EH; Gullberg, GT

    2017-01-01

    © 2015, American Society of Nuclear Cardiology. Background: The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Methods: Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients w...

  5. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  6. Optimized methods to measure acetoacetate, 3-hydroxybutyrate, glycerol, alanine, pyruvate, lactate and glucose in human blood using a centrifugal analyser with a fluorimetric attachment.

    Science.gov (United States)

    Stappenbeck, R; Hodson, A W; Skillen, A W; Agius, L; Alberti, K G

    1990-01-01

    Optimized methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, D-3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood using the Cobas Bio centrifugal analyser. Glucose and lactate are measured using the photometric mode and other metabolites using the fluorimetric mode. The intra-assay coefficients of variation ranged from 0.7 to 4.1%, except with very low levels of pyruvate and acetoacetate where the coefficients of variation were 7.1 and 12% respectively. All seven metabolites can be measured in a perchloric acid extract of 20 mul of blood. The methods have been optimized with regard to variation in the perchloric acid content of the samples. These variations arise from the method of sample preparation used to minimize changes occurring in metabolite concentration after venepuncture.

  7. Effect of sumatriptan on cerebral blood flow during migraine headache. Measurement by sequential SPECT used 99mTc-ECD background subtraction method

    International Nuclear Information System (INIS)

    Ueda, Takashi; Torihara, Yoshito; Tsuneyoshi, Noritaka; Ikeda, Yoshitomo

    2001-01-01

    The present study was designed to examine the effect of sumatriptan on regional cerebral blood flow (CBF) during migraine headache. Nine cases were examined by 99m Tc-ECD background subtraction method for the absolute value measurement of regional CBF before and after sumatriptan injection. rCBF except for occipital and perioccipital lobes, were increased 10-20% during migraine headache and significant decreases were observed by sumatriptan injection. Two cases of nine had transiently increased systemic blood pressure and cardiac pulse rate, however, all cases improved migraine headache after injection of sumatriptan. (author)

  8. Effect of sumatriptan on cerebral blood flow during migraine headache. Measurement by sequential SPECT used {sup 99m}Tc-ECD background subtraction method

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Takashi; Torihara, Yoshito; Tsuneyoshi, Noritaka; Ikeda, Yoshitomo [Miyazaki Social Insurance Hospital (Japan)

    2001-07-01

    The present study was designed to examine the effect of sumatriptan on regional cerebral blood flow (CBF) during migraine headache. Nine cases were examined by {sup 99m}Tc-ECD background subtraction method for the absolute value measurement of regional CBF before and after sumatriptan injection. rCBF except for occipital and perioccipital lobes, were increased 10-20% during migraine headache and significant decreases were observed by sumatriptan injection. Two cases of nine had transiently increased systemic blood pressure and cardiac pulse rate, however, all cases improved migraine headache after injection of sumatriptan. (author)

  9. Insuring quality during implementation of a SPEDT method of regional cerebral blood flow measurements into daily routine

    International Nuclear Information System (INIS)

    Mathiassen, B.; Landsfeldt, U.S.; Broechner-Mortensen, J.; Andersen, A.R.; Pedersen, B.; Roedbro, P.

    1995-01-01

    The present aim was to describe a method for quality insurance when a previously experimental technique is implemented for daily clinical use. Regional cerebral blood flow (rCBF) was studied in 24 patients with medically intractable complex partial epilepsy using SPECT of the Tc99m-HMPAO distribution. The colour-coded rCBF images were evaluated visually four times by four observers who classified each data set into one of four ranked classes (normal, slightly - , median - or severely abnormal). The visual analysis was compared to the results obtained by an expert (the standard). After two evaluation rounds a teaching session of image interpretation was performed with emphasis on the most difficult problem cases. The results of the primary evaluation and the yield of the teaching round was assessed by error-points depending on the magnitude of the misinterpretation of each data set. Interobserver discrepancies was analyzed by Friedman's test of variance, while intra-observer variability was evaluated by Wilcoxon's paired non-parametric test. The teaching round improved the performance of the four observers significantly (p=0.0004), but not to the wanted quality standard for all observers. The reproducibility was improved in all, but not significantly. The insurance of quality during implementation of a new diagnostic method can thus be performed in a simple way providing the steering team with identification of problems, as well as inspiration to solution of critical problems. The presented quality insurance method can easily be performed when other imaging modalities are started or when quality control of a routine method is needed. (au)

  10. Blood proteins analysis by Raman spectroscopy method

    Science.gov (United States)

    Artemyev, D. N.; Bratchenko, I. A.; Khristoforova, Yu. A.; Lykina, A. A.; Myakinin, O. O.; Kuzmina, T. P.; Davydkin, I. L.; Zakharov, V. P.

    2016-04-01

    This work is devoted to study the possibility of plasma proteins (albumin, globulins) concentration measurement using Raman spectroscopy setup. The blood plasma and whole blood were studied in this research. The obtained Raman spectra showed significant variation of intensities of certain spectral bands 940, 1005, 1330, 1450 and 1650 cm-1 for different protein fractions. Partial least squares regression analysis was used for determination of correlation coefficients. We have shown that the proposed method represents the structure and biochemical composition of major blood proteins.

  11. Optimized methods to measure acetoacetate, 3-hydroxybutyrate, glycerol, alanine, pyruvate, lactate and glucose in human blood using a centrifugal analyser with a fluorimetric attachment

    OpenAIRE

    Stappenbeck, R.; Hodson, A. W.; Skillen, A. W.; Agius, L.; Alberti, K. G. M. M.

    1990-01-01

    Optimized methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, D-3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood using the Cobas Bio centrifugal analyser. Glucose and lactate are measured using the photometric mode and other metabolites using the fluorimetric mode. The intra-assay coefficients of variation ranged from 0.7 to 4.1%, except with very low levels of pyruvate and acetoacetate where the coefficients of variation were ...

  12. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    Science.gov (United States)

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  13. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  14. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  15. Radioisotope method for assessing skin blood pressure

    International Nuclear Information System (INIS)

    Tarkowska, A.; Misiunia, P.; Woytowicz, A.; Olewinski, T.

    1979-01-01

    A method of measuring the skin blood pressure (SBP) evolved by Holstein and Lassen is described. The method is based on determination of the force of pressure causing blockade of Na 131 I clearance from the site of its intradermal injection. Using this method it was found that in the lower extremities in healthy subjects the SBP approached the diastolic pressure measured by the conventional method in the brachial artery. On the other hand in patients with obliterative arteriosclerosis and in Buerger's disease the SBP was considerably lower than the diastolic arterial pressure. The authors think that the method gives a good insight into the state of blood supply to the extremities in healthy subjects and in peripheral vascular failure. (author)

  16. Development and validation of a sensitive UPLC-MS/MS method for the quantitation of [(13)C]sucrose in rat plasma, blood, and brain: Its application to the measurement of blood-brain barrier permeability.

    Science.gov (United States)

    Miah, Mohammad K; Bickel, Ulrich; Mehvar, Reza

    2016-03-15

    Accurate and reproducible measurement of blood-brain barrier (BBB) integrity is critical in the assessment of the pathophysiology of the central nervous system disorders and in monitoring therapeutic effects. The widely-used low molecular weight marker [(14)C]sucrose is non-specific in the absence of chromatographic separation. The purpose of this study was to develop and validate a sensitive and reproducible LC-MS/MS method for the analysis of stable isotope-modified [(13)C12]sucrose in brain, plasma, and blood to determine BBB permeability to sucrose. After addition of internal standard (IS, [(13)C6]sucrose), the marker and IS were recovered from diluted rat blood, plasma, and brain homogenate by protein precipitation using acetonitrile. The recovery of the marker and IS was almost quantitative (90-106%) for all three matrices. The recovered samples were directly injected into an isocratic UPLC system with a run time of 6 min. Mass spectrometry was conducted using multiple reaction monitoring in negative mode. The method was linear (r(2)≥0.99) in the concentration ranges tested for the diluted blood and plasma (10-1000 ng/mL) and brain homogenate (1-200 ng/mL). The lower limit of quantitation of the assay was 0.5 pg injected on column. The assay was validated (n=5) based on acceptable intra- and inter-run accuracy and precision values. The method was successfully used for the measurement of serial blood and plasma and terminal brain concentrations of [(13)C12]sucrose after a single intravenous dose (10 mg/kg) of the marker to rats. As expected, the apparent brain uptake clearance values of [(13)C12]sucrose were low in healthy rats. The method may be useful for determination of the BBB integrity in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Measurement of in vivo HGPRT-deficient mutant cell frequency using a modified method for cloning human peripheral blood T-lymphocytes

    International Nuclear Information System (INIS)

    Hakoda, Masayuki; Akiyama, Mitoshi; Kyoizumi, Seishi; Kobuke, Kyoko; Awa, A.A.

    1987-07-01

    Approximately 80 % of human peripheral blood T-lymphocytes could be cloned in the presence of crude Interleukin-2, phytohemagglutinin, and X-irradiated autologous lymphocytes and Raji B-cells. This modified cloning method was used to measure the in vivo frequency of HGPRT-deficient mutant T-lymphocytes. Repeated experiments using blood from the same individuals revealed that the frequency of mutant cells was almost constant for each individual even though the cloning efficiency of lymphocytes varied somewhat from experiment to experiment. Approximately 80 % of both wild-type unselected and 6-thioguanine-resistant colonies had helper/inducer and about 20 % had suppressor/cytotoxic T-lymphocyte markers. No difference was observed in the distribution of lymphocyte subsets between wild and mutant lymphocyte colonies. (author)

  18. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  19. Technical investigation of cerebral blood flow measurements using the Patlak plot method. A contrivance for positioning of the gamma camera at data collection in radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takaki, Akihiro; Okada, Kazuhiro; Urata, Johji; Yonehara, Toshiro [Saiseikai Kumamoto Hospital (Japan); Mizuta, Yoshihiko

    1999-02-01

    The time-activity curve for the aortic arch obtained from radionuclide angiography (RNA) is handled as an input function parameter according to the method of Matsuda et al., which determines regional cerebral blood flow non-invasively. The data are collected from a frontal view of the thorax captured by RNA by their method, however we encountered a case in which it was difficult to identify aortic arch in the data collection from the frontal view. The precise identification of the aortic arch was implemented when the RNA data were collected from the left anterior oblique view of the thorax. No significant difference was noted in the measured values between the data collection from the frontal view and from the left anterior oblique view. Our method seems to be useful modification of the Patlak plot method. (author)

  20. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  1. A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors.

    Science.gov (United States)

    Pflugradt, Maik; Geissdoerfer, Kai; Goernig, Matthias; Orglmeister, Reinhold

    2017-01-14

    Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations' vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway.

  2. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  3. Quantitative measurement of the cerebral blood flow

    International Nuclear Information System (INIS)

    Houdart, R.; Mamo, H.; Meric, P.; Seylaz, J.

    1976-01-01

    The value of the cerebral blood flow measurement (CBF) is outlined, its limits are defined and some future prospects discussed. The xenon 133 brain clearance study is at present the most accurate quantitative method to evaluate the CBF in different regions of the brain simultaneously. The method and the progress it has led to in the physiological, physiopathological and therapeutic fields are described. The major disadvantage of the method is shown to be the need to puncture the internal carotid for each measurement. Prospects are discussed concerning methods derived from the same general principle but using a simpler, non-traumatic way to introduce the radio-tracer, either by breathing into the lungs or intraveinously [fr

  4. Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings.

    Directory of Open Access Journals (Sweden)

    Kathrine Stene-Johansen

    Full Text Available Hepatitis B virus (HBV quantification is essential in the management of chronic hepatitis B, both to determine treatment eligibility and in the monitoring of treatment effect. This test, however, is rarely available in resource-limited settings due to high costs and stringent requirements for shipment and storage of plasma. Dried Blood Spots (DBS can be a convenient alternative to plasma, but its use for HBV monitoring has not been investigated under real-life conditions in Africa.The performance of DBS in HBV quantification was investigated using a modified commercial test (Abbott RealTime HBV assay. Paired DBS and plasma samples were collected from an HBV positive cohort in Addis Ababa, Ethiopia. DBS were stored at ambient temperature for 4-39 days before shipment to the laboratory.Twenty-six paired samples were selected covering the total range of quantification, from 2.14 log IU/ml to >7 log IU/ml. HBV was detected in 21 of 21 (100% DBS from patients with a corresponding plasma viral load above 2.70 log IU/ml. The mean difference between plasma and DBS was 0.59 log IU/ml, and the correlation was strong (R2 = 0.92. In stability studies there was no significant change in DBS viral load after storage at room temperature for up to 12 weeks.This study suggests that DBS can be a feasible and reliable alternative to plasma for quantification of HBV in resource-limited settings. DBS can expand access to antiviral treatment for patients in low- and middle-income countries.

  5. Development of a new Xe-133 single dose multi-step method (SDMM) for muscle blood flow measurement using gamma camera

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Seto, Mikito; Taki, Junichi

    1985-01-01

    In order to measure the muscle blood flow (MBF) during exercise (Ex), a new Xe-133 single dose multi-step method (SDMM) for leg MBF measurement before, during and after Ex using gamma camera was developped. Theoretically, if the activity of Xe-133 in the muscle immediately before and after Ex are known, then the mean MBF during Ex can be calculated. In SDMM, these activities are corrected through correction formula using time delays between end of data aquisition (DA) at rest (R1) and begining of the Ex (TAB), and between end of Ex and begining of the DA after Ex (R2) (TDA). Validity of the SDMM and MBF response on mild and heavy Ex were evaluated in 11 normal volunteers. Ex MBF calculated from 5 and 2.5 min DA (5 sec/frame) both at R1 and R2 were highly correlated (r=.996). Ex MBF by SDMM and direct(measurement by fixed leg exercise were also highly correlated (r=.999). Reproducibility of the R1 and Ex MBF were excellent (r=.999). The highest MBF was seen in GCM on miled walking Ex and in VLM on heavy squatting Ex. After miled Ex, MBF rapidly returned to normal. After heavy Ex, MBF remaind high in VLM In conclusion, SDMM is simple and accurate method for evaluation of dynamic MBF response according to exercise. SDMM is also applicable to the field of sports medicine. (author)

  6. Measurement of absolute bone blood flow by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, C.; Cockshott, W.P.; Garnett, E.S.; Belbeck, L.W.

    1986-03-01

    A method of measuring bone blood flow has been developed using /sup 18/F sodium fluoride and positron emission tomography. The blood flow levels are in line with those obtained experimentally from microsphere embolisation. This investigative method could be applied to elucidate a number of clinical questions involving bone perfusion.

  7. Measuring Post-transfusion Recovery and Survival of Red Blood Cells: Strengths and Weaknesses of Chromium-51 Labeling and Alternative Methods

    Directory of Open Access Journals (Sweden)

    Camille Roussel

    2018-05-01

    Full Text Available The proportion of transfused red blood cells (RBCs that remain in circulation is an important surrogate marker of transfusion efficacy and contributes to predict the potential benefit of a transfusion process. Over the last 50 years, most of the transfusion recovery data were generated by chromium-51 (51Cr-labeling studies and were predominantly performed to validate new storage systems and new processes to prepare RBC concentrates. As a consequence, our understanding of transfusion efficacy is strongly dependent on the strengths and weaknesses of 51Cr labeling in particular. Other methods such as antigen mismatch or biotin-based labeling can bring relevant information, for example, on the long-term survival of transfused RBC. These radioactivity-free methods can be used in patients including from vulnerable groups. We provide an overview of the methods used to measure transfusion recovery in humans, compare their strengths and weaknesses, and discuss their potential limitations. Also, based on our understanding of the spleen-specific filtration of damaged RBC and historical transfusion recovery data, we propose that RBC deformability and morphology are storage lesion markers that could become useful predictors of transfusion recovery. Transfusion recovery can and should be accurately explored by more than one method. Technical optimization and clarification of concepts is still needed in this important field of transfusion and physiology.

  8. Study on the Measurement of 51Cr-tagged Red Cell Survival: Reevaluation of its method and the effect of Blood loss on red cell survival with 51Cr

    International Nuclear Information System (INIS)

    Choi, Hak Yong; Koh, Chang Soon; Lee, Moon Ho

    1970-01-01

    Reappraisal measurement of apparent half survival time of red cell by 51 Cr method was made and effects of blood-letting over red cell survival were observed. The study was performed on 53 normal male subjects under three different experimental conditions. 1) Group 1: Mean 51 Cr red cell half survival by ACD wash method was 29.7 days. T 1 /2 of Ascorbic acid method was 29.0 days in group with 100 mg dose and 29.1 days in group with 50 mg dose respectively. There was no difference between these two methods in regards to red cell half survival. No difference were noted in amount of ascorbic acid administered. 2) Group 2: As daily amount of blood loss in increased the shortening of red cell half survival was noted. Rapid phase was seen when blood loss ranged 10 to 25 ml per day, while slow phase noted when more loss amounted 25 ml more daily. Thus, it was clear that there was more than an exponential relation between T 1 /2 and the amount of blood loss. 3) Group 3: T 1 /2 measured cpm per whole blood was within normal range and T 1 /2 measured by cpm per red mass showed shortening tendency when compared with the former in the group measured after blood loss (from 25 ml daily up to 100 ml daily in 10 days). In the group with rather constant blood loss of 100 ml daily for 10 consecutive days revealed the significant difference in two measurement (P 1 /2 in non-steady state. When red cell production is increased compared with red cell destruction, T 1 /2 measured by cpm per red cell mass shorter than that by cpm per whole blood. Shortening of T 1 /2 measured by cpm per whole blood is more prominent, if red destruction is enhanced and exceeds production. 5) It is clear that when expressing red cell destruction rate, T 1 /2 measured by cpm per whole blood is more adequate and production more consistent with cpm red cell mass. 6) T 1 /2 measured during blood-letting, when corrected by amount of blood loss, it remains normal. It is erroneous to use conventional equational

  9. Hybrid Optical Unobtrusive Blood Pressure Measurements

    Directory of Open Access Journals (Sweden)

    Guangfei Zhang

    2017-07-01

    Full Text Available Blood pressure (BP is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT calculated by a pair of photoplethysmography (PPG signals at two body sites. Currently, contact PPG (cPPG and imaging PPG (iPPG are two feasible ways to obtain PPG signals. In this study, we proposed a hybrid system (called the ICPPG system employing both methods that can be implemented on a wearable device, facilitating the measurement of BP in an inconspicuous way. The feasibility of the ICPPG system was validated on a dataset with 29 subjects. It has been proved that the ICPPG system is able to estimate PTT values. Moreover, the PTT measured by the new system shows a correlation on average with BP variations for most subjects, which could facilitate a new generation of BP measurement using wearable and mobile devices.

  10. Neonatal blood gas sampling methods

    African Journals Online (AJOL)

    You work in a regional neonatal intensive care unit. An 8-day-old ... The baby was born at 28 weeks' gestation with a birth weight of 1. 100 g. ... and arterial blood taken from indwelling arterial lines.2-4 However, even ... tal age of 48 - 72 hours.

  11. Assessing Pharmacy Students’ Ability to Accurately Measure Blood Pressure Using a Blood Pressure Simulator Arm

    Science.gov (United States)

    Bryant, Ginelle A.; Haack, Sally L.; North, Andrew M.

    2013-01-01

    Objective. To compare student accuracy in measuring normal and high blood pressures using a simulator arm. Methods. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. Results. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Conclusions. Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign. PMID:23788809

  12. Measurement of organ blood flow using tritiated water. II. Uterine blood flow in conscious pregnant ewes

    International Nuclear Information System (INIS)

    Brown, B.W.; Oddy, V.H.; Jones, A.W.

    1982-01-01

    Total uterine blood flow was measured with a tritiated water (TOH) diffusion method and with radioactive microspheres in six, conscious, pregnant ewes. With continuous infusion of TOH, equilibrium between the TOH concentration in utero-ovarian venous blood and arterial blood was attained within 50 min of the start of the infusion. The concentration of TOH in uterine and foetal tissue and in foetal blood water was the same as that in uterine venous water by 40 min; at this time, the concentration of TOH in the water of amniotic and allantoic fluids was 96% of that in uterine venous blood water. Estimates of total uterine blood flow obtained using TOH were highly correlated with those obtained with microspheres and the corresponding mean flow values obtained with the two techniques did not significantly differ. The percentage of the total uterine blood flow passing through arteriovenous anastomoses ranged from 1.4 to 3.3%

  13. [New non-volumetric method for estimating peroperative blood loss].

    Science.gov (United States)

    Tachoires, D; Mourot, F; Gillardeau, G

    1979-01-01

    The authors have developed a new method for the estimation of peroperative blood loss by measurement of the haematocrit of a fluid obtained by diluting the blood from swabs in a known volume of isotonic saline solution. This value, referred to a monogram, may be used to assess the volume of blood impregnating the compresses, in relation to the pre-operative or present haematocrit of the patient, by direct reading. The precision of the method is discussed. The results obtained justified its routine application in surgery in children, patients with cardiac failure and in all cases requiring precise compensation of per-operative blood loss.

  14. Measurement of bone blood flow in sheep

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; Lehner, C.E.; Pearson, D.W.; Kanikula, T.; Adler, G.; Venci, R.; Lanphier, E.H.; DeLuca, P.M. Jr.

    1984-01-01

    Bone blood flow in sheep tibia has been estimated via the measurement of the perfusion limited clearance of 41 Ar from the bone mineral matrix following fast neutron activation of 44 Ca. Tibia blood flows were estimated for the intact sheep, and after the installation of an intramedullary pressure tap to elevate bone marrow pressure by saline infusion. The results indicate that normal blood flow in the tibia is in the range of 1.1 to 3.7 ml/100ml-min in the intact animal and at normal marrow pressure. With an elevated intramedullary pressure of approximately 100 mmHg, the bone blood flow measured varied around 0.5 to 1.1 ml/100ml-min. 12 refs., 5 figs., 1 tab

  15. Validation of the 133Xe inhalation method for measuring brain stem and cerebellar blood flow in human subjects and the baboon

    International Nuclear Information System (INIS)

    Sakai, F.; Meyer, J. St.; Yamaguchi, F.; Yamamoto, M.; Shaw, T.; Juge, O.

    1979-01-01

    Regional cerebral blood flow (rCBF) measurements recorded by probes placed over the posterior fossa after 133 Xe inhalation have been validated here in. After inhalation, 133 Xe gas is distributed via arterial blood of both carotid an vertebrobasilar systems, so that it should be possible to measure rCBF of the brain stem and cerebellum if appropriate collimation, probe placement and selection of activity are employed. Detectors placed over the suboccipital regions may be subject to distortion by radioactivity derived from extracerebral sources so that the following questions were asked: 1) What is the counting geometry for each probe looking at this area 2) What is the extent of contamination from surrounding tissues 3) Are the flow values reproducible and in accordance with values obtained by other techniques 4) Are the flow values able to show predictable changes under physiological and pathological conditions Animal and human experiments designed to answer these questions are reported. (Auth.)

  16. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  17. Psychiatric and subjective symptoms and cerebral blood flow in patients with chronic cerebral infarction after treatment with Ca antagonist (nilvadipine). Quantitative measurement of cerebral blood flow by the 123IMP-SPECT ARG method

    International Nuclear Information System (INIS)

    Sakayori, Osamu; Kitamura, Shin; Mishina, Masahiro; Yamazaki, Mineo; Terashi, Akirou

    1997-01-01

    Psychiatric and subjective symptoms such as headache, dizziness, lack of spontaneity, anxiety, and a depressive state are often found in patients with chronic cerebral infarction. Some Ca antagonists are reported to relieve such symptoms. The purpose of the present study was to investigate the relationship between psychiatric and subjective symptoms and cerebral blood flow (CBF) in cerebral infarction and to evaluate the clinical effects of Ca antagonists from the standpoint of the cerebral circulation. Nilvadipine was administered to is patients with chronic cerebral infarction and their CBF was measured by the 123 IMP-SPECT ARG method before and at 8 weeks after the nilvadipine treatment. The CBF in patients with hypertension was increased by 11% after giving nilvadipine. Patients without hypertension showed no tendency for elevation of their CBF. Patients who were relieved from some psychiatric symptoms revealed a 14% increase of CBF in all cortical regions, and a significant increase was noted in the frontal and temporal regions. In other patients without changes in psychiatric symptoms, the CBF did not increase in any of the cortical regions. No relationship between symptoms and CBF was observed in any of the patients with subjective symptoms. Our study demonstrated a close correlation between psychiatric symptoms and CBF. We speculate that psychiatric symptoms in chronic cerebral infarction may reflect diffuse brain dysfunctions. We also conclude that nilvadipine is more effective in relieving psychiatric symptoms in patients with hypertensive cerebral infarction. It is inferred that nilvadipine may be more effective in relieving psychiatric symptoms in patients with hypertension. (author)

  18. Our experience of blood flow measurements using radioactive tracers

    International Nuclear Information System (INIS)

    Danet, Bernard.

    1974-01-01

    A critical study of blood flow measuring methods is proposed. After a review of the various diffusible and non-diffusible radioactive tracers and the corresponding detector systems, the principles which allow to measure blood flow from the data so obtained, are studied. There is a different principle of flow measurement for each type of tracer. The theory of flow measurement using non-diffusible tracers (human serum albumin labelled with 131 I or sup(99m)Tc, 113 In-labelled siderophiline) and its application to cardiac flow measurement are described first. Then the theory of flow measurement using diffusible tracers ( 133 Xe, 85 Kr) and its application to measurement of blood flow through tissues (muscles and kidney particularly) are described. A personal experience of this various flow measurements is reported. The results obtained, the difficulties encountered and the improvments proposed are developed [fr

  19. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  20. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation.

    Science.gov (United States)

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2017-02-01

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2  = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

  1. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  2. Noninvasive measurement of an index of renal blood flow

    International Nuclear Information System (INIS)

    Powers, T.A.; Rees, R.S.; Bowen, R.D.

    1983-01-01

    A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compartmental analysis principles. There is good correlation between renal blood flow estimated by this technique and that determined by microsphere injection

  3. Preventing blood transfusion failures: FMEA, an effective assessment method.

    Science.gov (United States)

    Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza

    2017-06-30

    Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.

  4. Randomized Comparison of the Therapeutic Effect of Acupuncture, Massage, and Tachibana-Style-Method on Stiff Shoulders by Measuring Muscle Firmness, VAS, Pulse, and Blood Pressure

    Directory of Open Access Journals (Sweden)

    Kazuhiro Tachibana

    2012-01-01

    Full Text Available To compare the therapeutic efficacy of acupuncture, massage, and Tachibana-Ryojutsu (one of Japanese traditional body balance therapy techniques (SEITAI, on stiff shoulders, the subjects’ muscle firmness, blood pressure, pulse, VAS, and body temperature were measured before and after the treatment. Forty-seven volunteer subjects gave written informed consent to participate in this study. The subjects were randomly divided into three groups to receive acupuncture, massage, or Tachibana-Ryojutsu. Each therapy lasted for 90 seconds. The acupuncture treatment was applied by a retaining-needle at GB-21, massage was conducted softly on the shoulders, and Tachibana-Ryojutsu treated only the muscles and joints from the legs to buttocks without touching the shoulders or backs. The study indicated that the muscle firmness and VAS of the Tachibana-Ryojutsu group decreased significantly in comparison with the acupuncture and massage groups after treatment.

  5. Methods for measuring shrinkage

    OpenAIRE

    Chapman, Paul; Templar, Simon

    2006-01-01

    This paper presents findings from research amongst European grocery retailers into their methods for measuring shrinkage. The findings indicate that: there is no dominant method for valuing or stating shrinkage; shrinkage in the supply chain is frequently overlooked; data is essential in pinpointing where and when loss occurs and that many retailers collect data at the stock-keeping unit (SKU) level and do so every 6 months. These findings reveal that it is difficult to benc...

  6. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  7. Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

    Science.gov (United States)

    Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.

    2017-03-01

    Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

  8. Estimating the measurement uncertainty in forensic blood alcohol analysis.

    Science.gov (United States)

    Gullberg, Rod G

    2012-04-01

    For many reasons, forensic toxicologists are being asked to determine and report their measurement uncertainty in blood alcohol analysis. While understood conceptually, the elements and computations involved in determining measurement uncertainty are generally foreign to most forensic toxicologists. Several established and well-documented methods are available to determine and report the uncertainty in blood alcohol measurement. A straightforward bottom-up approach is presented that includes: (1) specifying the measurand, (2) identifying the major components of uncertainty, (3) quantifying the components, (4) statistically combining the components and (5) reporting the results. A hypothetical example is presented that employs reasonable estimates for forensic blood alcohol analysis assuming headspace gas chromatography. These computations are easily employed in spreadsheet programs as well. Determining and reporting measurement uncertainty is an important element in establishing fitness-for-purpose. Indeed, the demand for such computations and information from the forensic toxicologist will continue to increase.

  9. The measurement of limb blood flow using technetium-labelled red blood cells

    International Nuclear Information System (INIS)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-01-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with 99 Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4+-3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1+-2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain. (author)

  10. Measurement of limb blood flow using technetium-labelled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-05-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with /sup 99/Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4 +- 3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1 +- 2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain.

  11. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  12. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  13. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  14. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  15. A new method to measure muscle protein synthesis in humans by endogenously introduced d9-leucine and using blood for precursor enrichment determination

    Science.gov (United States)

    Tran, Lee; Masters, Haley; Roust, Lori R; Katsanos, Christos S

    2015-01-01

    Enrichment from the easily accessible blood amino acid pool is commonly used as precursor enrichment to calculate rates of muscle protein fractional synthesis in relevant human studies in lieu of the less accessible muscle fluid amino acid pool. However, the accuracy of this approach depends largely on the extent to which there is low discrepancy in free amino acid enrichment between blood and muscle. Steady-state gradient (i.e., ratio) of amino acid enrichment between blood and muscle fluid in the basal state and in response to amino acid infusion were determined in five healthy subjects, and in association with two separate tracers: d9-leucine, introduced endogenously by the metabolism of d10-leucine (i.e., l-[2,3,3,4,5,5,5,6,6,6-2H10]leucine) infused in blood, and 13C6-phenylalanine introduced/infused in blood. The blood-to-muscle fluid amino acid enrichment ratio was lower (P enrichment introduced endogenously by intravenous infusion of d10-leucine provides a closer estimate of the muscle fluid amino acid enrichment, and its associated changes, than blood phenylalanine enrichment to calculate rates of muscle protein synthesis in humans. PMID:26243214

  16. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    Science.gov (United States)

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (pforearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (pforearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  17. Measured attenuation correction methods

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.K.; Doll, J.; Lorenz, W.J.

    1989-01-01

    Accurate attenuation correction is a prerequisite for the determination of exact local radioactivity concentrations in positron emission tomography. Attenuation correction factors range from 4-5 in brain studies to 50-100 in whole body measurements. This report gives an overview of the different methods of determining the attenuation correction factors by transmission measurements using an external positron emitting source. The long-lived generator nuclide 68 Ge/ 68 Ga is commonly used for this purpose. The additional patient dose from the transmission source is usually a small fraction of the dose due to the subsequent emission measurement. Ring-shaped transmission sources as well as rotating point or line sources are employed in modern positron tomographs. By masking a rotating line or point source, random and scattered events in the transmission scans can be effectively suppressed. The problems of measured attenuation correction are discussed: Transmission/emission mismatch, random and scattered event contamination, counting statistics, transmission/emission scatter compensation, transmission scan after administration of activity to the patient. By using a double masking technique simultaneous emission and transmission scans become feasible. (orig.)

  18. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  19. HbA1c measurements from dried blood spots : validation and patient satisfaction

    NARCIS (Netherlands)

    Fokkema, Margaretha; Bakker, Andries J; de Boer, Fokje; Kooistra, Jeltsje; de Vries, Sifra; Wolthuis, Albert

    2009-01-01

    Background: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood. Methods: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper

  20. Database of normal human cerebral blood flow measured by SPECT. II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Ito, Hiroshi; Shidahara, Miho

    2006-01-01

    The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123 I-IMP and SPECT, normal cerebral blood flow (CBF) of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. Quantitative CBF SPECT using 123 I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. The mean CBF in GM-ROIs were 31.7±6.6 and 41.0±8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2±0.7 and 22.9±0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9±12.8 and 65.8±16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H 2 15 O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly

  1. Comparison of high-definition oscillometry -- a non-invasive technology for arterial blood pressure measurement -- with a direct invasive method using radio-telemetry in awake healthy cats.

    Science.gov (United States)

    Martel, Eric; Egner, Beate; Brown, Scott A; King, Jonathan N; Laveissiere, Arnaud; Champeroux, Pascal; Richard, Serge

    2013-12-01

    This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into account all pressure ranges, and with data separated in three sub-groups, low, normal and high ranges of systolic (SBP) and diastolic (DBP) blood pressure. SBP data displayed a mean correlation coefficient of 0.92 ± 0.02 that was reduced for low SBP. The agreement level evaluated from the whole data set was high and slightly reduced for low SBP values. The mean correlation coefficient of DBP was lower than for SBP (ie, 0.81 ± 0.02). The bias for DBP between the two methods was 22.3 ± 1.6 mmHg, suggesting that HDO produced lower values than telemetry. These results suggest that HDO met the validation criteria defined by the American College of Veterinary Internal Medicine consensus panel and provided a faithful measurement of SBP in conscious cats. For DBP, results suggest that HDO tended to underestimate DBP. This finding is clearly inconsistent with the good agreement reported in dogs, but is similar to outcomes achieved in marmosets and cynomolgus monkeys, suggesting that this is not related to HDO but is species related. The data support that the HDO is the first and only validated non-invasive blood pressure device and, as such, it is the only non-invasive reference technique that should be used in future validation studies.

  2. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    , corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate......Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...

  3. Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals.

    Science.gov (United States)

    Wong, David M; Alcott, Cody J; Wang, Chong; Bornkamp, Jennifer L; Young, Jessica L; Sponseller, Brett A

    2011-11-15

    To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (PetCO(2)) and saturation of hemoglobin with oxygen as measured by pulse oximetry (SpO(2)) with direct measurements of PaCO(2) and calculated saturation of hemoglobin with oxygen in arterial blood (SaO(2)) in conscious healthy and ill foals. Validation study. 10 healthy and 21 ill neonatal foals. Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of PaCO(2) and PaO(2) along with SaO(2). Concurrently, PetCO(2) was measured with a capnograph inserted into a naris, and SpO(2) was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Mean ± SD difference between PaCO(2) and PetCO(2) was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between PaCO(2) and PetCO(2). Mean ± SD difference between SaO(2) and SpO(2) was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between SaO(2) and SpO(2). Both PetCO(2) obtained by use of nasal capnography and SpO(2) obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring PaCO(2) and SaO(2) in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.

  4. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular...... simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50-100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic...... pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons...

  5. Regional cerebral blood flow measurement in brain tumors

    International Nuclear Information System (INIS)

    Izunaga, Hiroshi; Hirota, Yoshihisa; Takahashi, Mutsumasa; Fuwa, Isao; Kodama, Takafumi; Matsukado, Yasuhiko

    1986-01-01

    The regional cerebral blood flow (CBF) was determined on seventeen patients with brain tumors. Ring type single photon emission CT (SPECT) was used following intravenous injection of 133 Xe. Case materials included eleven meningiomas and six malignant gliomas. Evaluation was performed with emphasis on the following points; 1. Correlation of the flow data within tumors to the angiographic tumor stains, 2. Influence of tumors on the cerebral blood flow of the normal brain tissue, 3. Correlation between degree of peripheral edema and the flow data of the affected hemispheres. There was significant correlation between flow data within tumors and angiographic tumor stains in meningiomas. Influence of tumors on cerebral blood flow of the normal tissue was greater in meningiomas than in gliomas. There was negative correlation between the degree of peripheral edema and the flow data of the affected hemisphere. It has been concluded that the measurement of CBF in brain tumors is a valuable method in evaluation of brain tumors. (author)

  6. Regional cerebral blood flow measurement in brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Izunaga, Hiroshi; Hirota, Yoshihisa; Takahashi, Mutsumasa; Fuwa, Isao; Kodama, Takafumi; Matsukado, Yasuhiko

    1986-10-01

    The regional cerebral blood flow (CBF) was determined on seventeen patients with brain tumors. Ring type single photon emission CT (SPECT) was used following intravenous injection of /sup 133/Xe. Case materials included eleven meningiomas and six malignant gliomas. Evaluation was performed with emphasis on the following points; 1. Correlation of the flow data within tumors to the angiographic tumor stains, 2. Influence of tumors on the cerebral blood flow of the normal brain tissue, 3. Correlation between degree of peripheral edema and the flow data of the affected hemispheres. There was significant correlation between flow data within tumors and angiographic tumor stains in meningiomas. Influence of tumors on cerebral blood flow of the normal tissue was greater in meningiomas than in gliomas. There was negative correlation between the degree of peripheral edema and the flow data of the affected hemisphere. It has been concluded that the measurement of CBF in brain tumors is a valuable method in evaluation of brain tumors.

  7. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  8. Simple, miniaturized blood plasma extraction method.

    Science.gov (United States)

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to

  9. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    -day workshop on the design, use and evaluation of prediction methods for blood glucose concentration was held at the Johannes Kepler University Linz, Austria. One intention of the workshop was to bring together experts working in various fields on the same topic, in order to shed light from different angles...... discussions which allowed to receive direct feedback from the point of view of different disciplines. This book is based on the contributions of that workshop and is intended to convey an overview of the different aspects involved in the prediction. The individual chapters are based on the presentations given...... in the process of writing this book: All authors for their individual contributions, all reviewers of the book chapters, Daniela Hummer for the entire organization of the workshop, Boris Tasevski for helping with the typesetting, Florian Reiterer for his help editing the book, as well as Oliver Jackson and Karin...

  10. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  11. Determination of blood circulation in oral formations using Rb86 distribution method and labelled micropearl method

    International Nuclear Information System (INIS)

    Fazekas, A.; Posch, E.; Harsing, L.

    1979-01-01

    The blood circulation of incisors, dental pulp and tongue was detemined using the measurement of 86 Rb distribution in rats. The results were compared with those obtained by a simultaneous micropearl method. It was found that 37 per cent of 86 Rb in dental tissues is localized in the hard propiodentium, with a high proportion diffusing from the periodontium. The 86 Rb fraction localized in the tongue represents its blood circulation. (author)

  12. Method comparison and validation of a prototype device for measurement of ionized calcium concentrations cow-side against a point-of-care instrument and a benchtop blood-gas analyzer reference method.

    Science.gov (United States)

    Neves, R C; Stokol, T; Bach, K D; McArt, J A A

    2018-02-01

    The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from

  13. Optically measured microvascular blood flow contrast of malignant breast tumors.

    Directory of Open Access Journals (Sweden)

    Regine Choe

    Full Text Available Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS, a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92-2.63; tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94-2.66, and using normal tissue in the contralateral breast was 2.27 (1.90-2.70. Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.

  14. Blood flow velocity measurements in chicken embryo vascular network via PIV approach

    Science.gov (United States)

    Kurochkin, Maxim A.; Stiukhina, Elena S.; Fedosov, Ivan V.; Tuchin, Valery V.

    2018-04-01

    A method for measuring of blood velocity in the native vasculature of a chick embryo by the method of micro anemometry from particle images (μPIV) is improved. A method for interrogation regions sorting by the mask of the vasculature is proposed. A method for sorting of the velocity field of capillary blood flow is implemented. The in vitro method was evaluated for accuracy in a glass phantom of a blood vessel with a diameter of 50 μm and in vivo on the bloodstream of a chicken embryo, by comparing the transverse profile of the blood velocity obtained by the PIV method with the theoretical Poiseuille laminar flow profile.

  15. The comparison of placental removal methods on operative blood loss

    International Nuclear Information System (INIS)

    Waqar, F.; Fawad, A.

    2008-01-01

    On an average 1 litre of blood is lost during Caesarean Section. Many variable techniques have been tried to reduce this blood loss. Many study trials have shown the spontaneous delivery of placenta method to be superior over manual method because of reduced intra operative blood loss and reduced incidence of post operative endometritis. The main objective of our study was to compare the risk of blood loss associated with spontaneous and manual removal of the placenta during caesarean section. This study was conducted at Department of Obstetrics and Gynaecology, Islamic International Medical Complex, Islamabad from September 2004 to September 2005. All Women undergoing elective or emergency caesarean section were included in the study. Exclusion criteria were pregnancy below 37 weeks, severe maternal anaemia, and prolonged rupture of the membranes with fever, placenta praevia, placenta accreta and clotting disorders. Patients were allocated to the two groups randomly. Group A comprised of women in whom the obstetrician waited a maximum of 5 minutes till the placenta delivered spontaneously. In group B the obstetrician manually cleaved out the placenta as soon as the infant was delivered. The primary outcome measures noted were difference in haemoglobin of >2 gm/dl (preoperatively and postoperatively), time interval between delivery of baby and placenta, significant blood loss (>1000 cc), additional use of oxytocics, total operating time and blood transfusions. Data was analysed by SPSS. Statistical tests used for specific comparison were chi square-test and Student's t-test. One hundred and forty-five patients were allocated to two groups randomly. Seventy-eight patients were allocated to group A and 67 patients allocated to group B. Mean maternal age, birth weight, and total operating time were the same in two groups, but blood loss as measured by a difference in haemoglobin of greater then 2 grams/dl was statistically significant. Significant blood loss (>1000 cc

  16. Blood cell labeling with technetium-99m. II. Measurement of circulating blood volume by sup(99m)Tc-labeled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T; Yoshida, H; Matsuda, S; Kimura, H; Miura, N [Fukushima Medical Coll. (Japan)

    1978-02-01

    Using a labeling method with sup(99m)Tc-pertechnetate to red blood cells (RBC), circulating blood volume was measured in comparison with that from /sup 51/Cr-labeled RBC method. The technique is easier than already published methods, because CIS kit for sup(99m)Tc-RBC labeling (TCK-11) became to be available recently. Two mls of ACD-anticoagulated blood were withdrawn and 0.5 ml of reducing reagent prepared just before use was added to blood, waiting 5 minutes and discarding the serum after centrifugation, then adding 100 ..mu..Ci of sup(99m)Tc. After washing the labeled cells by isotonic saline, cells were re-suspended in 10 ml of saline and injected to the subject. Blood specimen was obtained 10, 30, 60 and 120 minutes after infusion and blood volume was calculated by the usual way. Circulating blood volume by sup(99m)Tc was well correlated with that by /sup 51/Cr (=0.98, p 0.01), however, the value calculated from sup(99m)Tc were 4.8 percent higher than those by /sup 51/Cr, which suggested the elution of sup(99m)Tc from labeled RBC. sup(99m)Tc method has the advantages that higher radioactivity can be obtained in small amount of blood, which is useful in the determination of blood volume in children or in small animals in the laboratory. The measurement of blood volume of the mouse was done by using sup(99m)Tc method. The results were 1.70 +- 0.06 ml (6.35 +- 0.18%/gm), which coincided with the values reported previously. Because of it's short half life and low radiation dosage to the patients, sup(99m)Tc method will be recommended in the field of pediatrics or in patients with polycythemia or congestive heart failure, who are requested the repeated measurement of blood volume.

  17. Cerebral blood flow measurement in cerebrovascular occlusive diseases

    International Nuclear Information System (INIS)

    Yanagihara, T.; Wahner, H.W.

    1984-01-01

    In order to evaluate cerebral blood flow (CBF) patterns among individual patients with increased statistical confidence, CBF measurements were carried out using the 133Xe-inhalation method and external head detectors. F1 values representing gray matter flow from 3 to 6 head detectors were averaged to form 16 different regions for each cerebral hemisphere. Normative values were obtained from 46 healthy volunteers, and data from individual regions were analyzed for absolute blood flow rates (ml/100g/min), for concordance between right and left hemispheres and as percent of mean hemispheric flow. CBF measurements were then carried out among 37 patients with cerebrovascular occlusive diseases, and results were compared with normative values. A high incidence of abnormal flows were detected among symptomatic patients with intracranial arterial stenosis or occlusion and those with extracranial internal carotid artery occlusion. By using the above method for data analysis, it was possible to delineate hypoperfused areas among these patients. Even though the 133Xe-inhalation method has inherent limitations, this is a practical and safe method for measurement of CBF which can provide reliable information useful for management of patients with cerebrovascular occlusive diseases, particularly when the results are presented with statistical confidence

  18. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  19. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  20. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...

  1. Rapid measurement of blood leakage during regional chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, C. (Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Nuklearmedizin); Omlor, G.; Gross, G.; Feifel, G. (Universitaet des Saarlandes, Homburg/Saar (Germany). Abt. fuer Allgemeine Chirurgie); Berberich, R. (Staedtische Klinik Wuppertal (Germany). Abt. fuer Nuklearmedizin)

    1993-03-01

    A method using technetium-99m in vivo red blood cell (RBC) labelling is reported that provides results within 3 min. Blood samples drawn from the systemic and the extracorporeal circulation were measured for [sup 99m]Tc activity using a mobile well counter, and the leakage values calculated. The mean result was 7.6%[+-]6.5%/15 min (n=209). The corresponding flow rate was 100.2[+-]85.7 ml/15 min. The values for isolation perfusion of the upper and the lower extremities are compared. The leakage results using [sup 99m]Tc RBC labelling were correlated with other blood pool markers. Iodine-125 human serum albumin and indium-113 m transferrin were administered in subgroups of 4 and 19 patients simultaneously. Using linear regression, the coefficient of correlation was 0.72 for [sup 99m]Tc/[sup 113m]In and 0.58 for [sup 99m]Tc/[sup 125]I. Comparison with the alternatives suggests that the method can be considered one of the most practicable and reliable methods available. (orig.).

  2. X-ray PIV measurements of blood flows without tracer particles

    International Nuclear Information System (INIS)

    Kim, Guk Bae; Lee, Sang Joon

    2006-01-01

    We analyzed the non-Newtonian flow characteristics of blood moving in a circular tube flow using an X-ray PIV method and compared the experimental results with hemodynamic models. The X-ray PIV method was improved for measuring quantitative velocity fields of blood flows using a coherent synchrotron X-ray. Without using any contrast media, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells. The enhanced X-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit in detail. The quantitative velocity fields of blood flows inside opaque conduits were obtained by applying a two-frame PIV algorithm to the X-ray images of the blood flows. The measured velocity data show typical features of blood flow such as the yield stress and shear-thinning effects. (orig.)

  3. Blood pulsation measurement using cameras operating in visible light: limitations.

    Science.gov (United States)

    Koprowski, Robert

    2016-10-03

    The paper presents an automatic method for analysis and processing of images from a camera operating in visible light. This analysis applies to images containing the human facial area (body) and enables to measure the blood pulse rate. Special attention was paid to the limitations of this measurement method taking into account the possibility of using consumer cameras in real conditions (different types of lighting, different camera resolution, camera movement). The proposed new method of image analysis and processing was associated with three stages: (1) image pre-processing-allowing for the image filtration and stabilization (object location tracking); (2) main image processing-allowing for segmentation of human skin areas, acquisition of brightness changes; (3) signal analysis-filtration, FFT (Fast Fourier Transformation) analysis, pulse calculation. The presented algorithm and method for measuring the pulse rate has the following advantages: (1) it allows for non-contact and non-invasive measurement; (2) it can be carried out using almost any camera, including webcams; (3) it enables to track the object on the stage, which allows for the measurement of the heart rate when the patient is moving; (4) for a minimum of 40,000 pixels, it provides a measurement error of less than ±2 beats per minute for p lighting; (5) analysis of a single image takes about 40 ms in Matlab Version 7.11.0.584 (R2010b) with Image Processing Toolbox Version 7.1 (R2010b).

  4. Assessing pharmacy students' ability to accurately measure blood pressure using a blood pressure simulator arm.

    Science.gov (United States)

    Bottenberg, Michelle M; Bryant, Ginelle A; Haack, Sally L; North, Andrew M

    2013-06-12

    To compare student accuracy in measuring normal and high blood pressures using a simulator arm. In this prospective, single-blind, study involving third-year pharmacy students, simulator arms were programmed with prespecified normal and high blood pressures. Students measured preset normal and high diastolic and systolic blood pressure using a crossover design. One hundred sixteen students completed both blood pressure measurements. There was a significant difference between the accuracy of high systolic blood pressure (HSBP) measurement and normal systolic blood pressure (NSBP) measurement (mean HSBP difference 8.4 ± 10.9 mmHg vs NSBP 3.6 ± 6.4 mmHg; pdifference between the accuracy of high diastolic blood pressure (HDBP) measurement and normal diastolic blood pressure (NDBP) measurement (mean HDBP difference 6.8 ± 9.6 mmHg vs. mean NDBP difference 4.6 ± 4.5 mmHg; p=0.089). Pharmacy students may need additional instruction and experience with taking high blood pressure measurements to ensure they are able to accurately assess this important vital sign.

  5. Using the area under the curve to reduce measurement error in predicting young adult blood pressure from childhood measures.

    Science.gov (United States)

    Cook, Nancy R; Rosner, Bernard A; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2004-11-30

    Tracking correlations of blood pressure, particularly childhood measures, may be attenuated by within-person variability. Combining multiple measurements can reduce this error substantially. The area under the curve (AUC) computed from longitudinal growth curve models can be used to improve the prediction of young adult blood pressure from childhood measures. Quadratic random-effects models over unequally spaced repeated measures were used to compute the area under the curve separately within the age periods 5-14 and 20-34 years in the Bogalusa Heart Study. This method adjusts for the uneven age distribution and captures the underlying or average blood pressure, leading to improved estimates of correlation and risk prediction. Tracking correlations were computed by race and gender, and were approximately 0.6 for systolic, 0.5-0.6 for K4 diastolic, and 0.4-0.6 for K5 diastolic blood pressure. The AUC can also be used to regress young adult blood pressure on childhood blood pressure and childhood and young adult body mass index (BMI). In these data, while childhood blood pressure and young adult BMI were generally directly predictive of young adult blood pressure, childhood BMI was negatively correlated with young adult blood pressure when childhood blood pressure was in the model. In addition, racial differences in young adult blood pressure were reduced, but not eliminated, after controlling for childhood blood pressure, childhood BMI, and young adult BMI, suggesting that other genetic or lifestyle factors contribute to this difference. 2004 John Wiley & Sons, Ltd.

  6. Blood lipid measurements. Variations and practical utility.

    Science.gov (United States)

    Cooper, G R; Myers, G L; Smith, S J; Schlant, R C

    1992-03-25

    To describe the magnitude and impact of the major biological and analytical sources of variation in serum lipid and lipoprotein levels on risk of coronary heart disease; to present a way to qualitatively estimate the total intraindividual variation; and to demonstrate how to determine the number of specimens required to estimate, with 95% confidence, the "true" underlying total cholesterol value in the serum of a patient. Representative references on each source of variation were selected from more than 300 reviewed publications, most published within the past 5 years, to document current findings and concepts. Most articles reviewed were in English. Studies on biological sources of variation were selected using the following criteria: representative of published findings, clear statement of either significant or insignificant results, and acquisition of clinical and laboratory data under standardized conditions. Representative results for special populations such as women and children are reported when results differ from those of adult men. References were selected based on acceptable experimental design and use of standardized laboratory lipid measurements. The lipid levels considered representative for a selected source of variation arose from quantitative measurements by a suitably standardized laboratory. Statistical analysis of data was examined to assure reliability. The proposed method of estimating the biological coefficient of variation must be considered to give qualitative results, because only two or three serial specimens are collected in most cases for the estimation. Concern has arisen about the magnitude, impact, and interpretation of preanalytical as well as analytical sources of variation on reported results of lipid measurements of an individual. Preanalytical sources of variation from behavioral, clinical, and sampling sources constitute about 60% of the total variation in a reported lipid measurement of an individual. A technique is presented

  7. Colour measurement and white blood cell recognition

    CERN Document Server

    Gelsema, E S

    1972-01-01

    As a part of a collaboration with NEMCH aimed at the automation of the differential white blood cell count, studies have been made of the different possibilities for using colour to help in the recognition process. Results are presented comparing data obtained with a microspectrophotometer and with a simulated three-colour scanner.

  8. Hybrid optical unobtrusive blood pressure measurements

    NARCIS (Netherlands)

    Zhang, G.; Shan, C.; Kirenko, I.; Long, X.; Aarts, R.M.

    2017-01-01

    Blood pressure (BP) is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT) calculated by a pair of photoplethysmography (PPG) signals at two body sites. Currently, contact PPG (cPPG) and

  9. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  10. Measurement of regional cerebral blood flow by positron emission tomography

    International Nuclear Information System (INIS)

    Herscovitch, P.; Powers, W.J.

    1987-01-01

    The principal advantage of positron emission tomography over other methods for measuring cerebral blood flow stems from the accurate, quantitative three-dimensional measurements of regional brain radioactivity that are possible with this technique. As a result, accurate quantitative measurements of regional cerebral blood flow can be obtained for both superficial and deep cerebral structures. The value of PET for investigating central nervous system physiology and pathology extends far beyond this, however. Through the use of different radiotracers and appropriate mathematical models, PET can be applied to the measurement of a wide variety of physiologic variables. Measurements of rCBF tell only part of the story. Experience with PET and with a variety of other techniques has taught us that rCBF is at times a poor indicator of the metabolic, functional, and biochemical status of cerebral tissue. It is only by understanding the interaction of all of these factors that our understanding of neurologic disease can advance. It is in the investigation of these complex relationships that the real value of PET resides

  11. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods.

    Science.gov (United States)

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-03-01

    Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients' blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine.

  12. Single-cell measurement of red blood cell oxygen affinity

    OpenAIRE

    Caprio, Di; Stokes, Chris; Higgins, John M.; Schonbrun, Ethan

    2015-01-01

    Oxygen is transported throughout the body by hemoglobin in red blood cells. While the oxygen affinity of blood is well understood and is routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of red blood cell volume and hemoglobin concentration are taken millions of times per day by clinical hematology analyzers and are important factors in determining the health of the hematologic system....

  13. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  14. Optimal method for collection of umbilical cord blood: an Egyptian trial for a public cord blood bank.

    Science.gov (United States)

    Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A

    2015-06-01

    Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.

  15. Database of normal human cerebral blood flow measured by SPECT: II. Quantification of I-123-IMP studies with ARG method and effects of partial volume correction.

    Science.gov (United States)

    Inoue, Kentaro; Ito, Hiroshi; Shidahara, Miho; Goto, Ryoi; Kinomura, Shigeo; Sato, Kazunori; Taki, Yasuyuki; Okada, Ken; Kaneta, Tomohiro; Fukuda, Hiroshi

    2006-02-01

    The limited spatial resolution of SPECT causes a partial volume effect (PVE) and can lead to the significant underestimation of regional tracer concentration in the small structures surrounded by a low tracer concentration, such as the cortical gray matter of an atrophied brain. The aim of the present study was to determine, using 123I-IMP and SPECT, normal CBF of elderly subjects with and without PVE correction (PVC), and to determine regional differences in the effect of PVC and their association with the regional tissue fraction of the brain. Quantitative CBF SPECT using 123I-IMP was performed in 33 healthy elderly subjects (18 males, 15 females, 54-74 years old) using the autoradiographic method. We corrected CBF for PVE using segmented MR images, and analyzed quantitative CBF and regional differences in the effect of PVC using tissue fractions of gray matter (GM) and white matter (WM) in regions of interest (ROIs) placed on the cortical and subcortical GM regions and deep WM regions. The mean CBF in GM-ROIs were 31.7 +/- 6.6 and 41.0 +/- 8.1 ml/100 g/min for males and females, and in WM-ROIs, 18.2 +/- 0.7 and 22.9 +/- 0.8 ml/100 g/min for males and females, respectively. The mean CBF in GM-ROIs after PVC were 50.9 +/- 12.8 and 65.8 +/- 16.1 ml/100 g/min for males and females, respectively. There were statistically significant differences in the effect of PVC among ROIs, but not between genders. The effect of PVC was small in the cerebellum and parahippocampal gyrus, and it was large in the superior frontal gyrus, superior parietal lobule and precentral gyrus. Quantitative CBF in GM recovered significantly, but did not reach values as high as those obtained by invasive methods or in the H2(15)O PET study that used PVC. There were significant regional differences in the effect of PVC, which were considered to result from regional differences in GM tissue fraction, which is more reduced in the frontoparietal regions in the atrophied brain of the elderly.

  16. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  17. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación

    Directory of Open Access Journals (Sweden)

    Lynnette Neufeld

    2002-06-01

    Full Text Available Objective. To assess the comparability of hemoglobin concentration (Hb in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn and to document the influence of type of blood (capillary or venous and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Results. Capillary blood had higher Hb (+0.5g/dl than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3g/dl. Specificity to detect anemia was adequate (>0.90 but sensitivity was low for capillary blood assessed by Hemocue (Objetivo. Evaluar la comparabilidad de la concentración de hemoglobina (Hb en sangre venosa y capilar medida por Hemocue y por espectrofotómetro automatizado (Celldyn, así como documentar la influencia del tipo de sangre (capilar o venosa y del método de análisis sobre la prevalencia de anemia. Material y métodos. De febrero a mayo de 2000, se recolectaron muestras de sangre capilar y venosa en 72 adultos y niños en el Hospital del Niño Morelense, Cuernavaca, Morelos, México. Se determinaron los niveles de Hb con los métodos Hemocue y Celldyn. Las cifras de Hb estimadas se compararon con el coeficiente de concordancia y la prueba pareada de t de Student. También se comparó la sensibilidad y especificidad para el diagnóstico de anemia, utilizando sangre de los dos tipos y métodos de análisis. Resultados. La Hb fue mayor en sangre capilar comparada con sangre venosa

  18. Whole body [O-15]water pharmacokinetics measured in blood

    NARCIS (Netherlands)

    Maguire, RP; Spyrou, NM; Leenders, KL

    A simple pharmacokinetic model to explain the time course of [0-15]water in human whole blood after bolus injection is described. The model has been derived from measurements in twelve healthy volunteers who were measured repeatedly, resulting in 67 datasets, made in the context of PET blood flow

  19. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  20. Accuracy of Blood Loss Measurement during Cesarean Delivery

    OpenAIRE

    Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.

    2017-01-01

    Objective?This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design?In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood...

  1. Trace-element measurement in human blood samples

    International Nuclear Information System (INIS)

    Hamidian, M.R.; Ebrahimi-Fakhar, F.

    1992-01-01

    It is conceivable that some essential elements such as zinc, iron, calcium, copper, phosphorus, selenium, etc., have a major impact on biological and metabolical functions in the human body. The concentration of these elements is normally very minute and changes within a naturally set tolerance. The accurate measurement of these elements in biological samples, such as in blood, is one of the objectives of medical physics in diagnosis. There are many sophisticated methods to measure the accurate amount of each element in biological samples. The methods used in this project are a combination of proton-induced X-ray emission (PIXE) and neutron activation analysis (NAA). The PIXE and NAA are fast and reliable techniques for multielement analysis at the level of parts per million and less

  2. Cutaneous and subcutaneous blood flow measurements in psoriasis

    International Nuclear Information System (INIS)

    Klemp, P.

    1987-01-01

    The experiments - published in 7 papers in The Journal of Investigative Dermatology 1983-86 - have demonstrated: 1. The accuracy of the local 133 Xe washout method is about 15% for estimation of the cutaneous blood flow (CBF), and about 10% for subcutaneous blood flow measurements (SBF). In measurements of absolute CBF values a graphic curve resolution of the washout curve should alwaus be performed. Otherwise the CBF might be considerably underestimated. 2. CdTe(Cl) mini-detectors can be attached directly to the skin, and might yield measurements of both CBF and SBF that can substitute for those made with conventional detectors. 3. The laser Doppler measurements could not be correlated to quantitative measurements of the CBF. 4. The tissue-to-blood partition coefficient for 133 Xe of lesional psoriatic skin (LS) is increased. 5. In untreated, LS of patients with active psoriasis the CBF is about a factor of 10 times higher than the CBF of normal individuals. In non-lesional skin (NLS) of patients with active psoriasis the CBF is about a factor of 2 higher than the CBF of normal individuals. However, the CBF did not differ in NLS of patients with minimal skin manifestations. The high CBF decreases gradualy during antipsoriatic treatment. 6. A paradoxical autoregulation of the CBF was observed in LS. 7. The high CBF is not due to a maximally dilated vascular bed. 8. The SBF in LS areas was a factor of higher than the SBF in normal individuals. 9. A normal, local regulation of the SBF was found. (author)

  3. Measurement of hydroxylated PCB metabolites for Slovakia maternal blood serums

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.S.; Athanasiadou, M; Bergman, A. [Stockholm Univ., Stockholm (Sweden); Charles, J.; Zhao, G.; Hertz-Picciotto, I. [California Univ., Sacramento, CA (United States); Petrik, J.; Kocan, A; Trnovec, T. [Bratislava Inst. of Preventive and Clinical Medicine, Bratislava (Slovakia)

    2005-07-01

    Although it is known that polychlorinated biphenyls (PCBs) have adverse impacts on human health, it is not clear if human health impacts are caused by the PCBs or their related hydroxylated (OH) PCB metabolite compounds. This study measured OH-PCB metabolites in the maternal blood serum specimens from the Svidnik and Michalovce areas in eastern Slovakia where PCBs were intensively produced and inadequately disposed. The aim of the study was to characterize and quantify levels of specific OH-PCB metabolites in Slovakian maternal serums exposed to high environmental PCB levels. All specimens were analyzed for PCBs, and a subset of the samples was analyzed for OH-PCB metabolites. The Wallenburg blood extraction method was adopted to separate the OH-PCBs from the blood serums. Final eluates and calibration standards were spiked with PCB209 as an injection standard before gas chromatography (GC) analysis. OH-PCBs in the samples range from 75{+-}9 per cent to 101{+-}11 per cent. Median concentrations of OH-PCB metabolites of Michalovce samples were approximately twice as high as for the Svidnik samples. Concentrations of OH-PCBs of Michalovce blood samples were comparable to samples obtained from northern Canadian female Inuit and Faroe Island females, and were considered to be among the highest OH-PCB concentrations obtained in human blood. It was concluded that further research is needed to understand the placental transfer of OH-PCBs to the fetus, as well as epidemiological approaches to determine the relationship between the exposure of OH-PCB metabolites and child development. 12 refs., 2 figs.

  4. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  5. Automated methods of corrosion measurement

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Bech-Nielsen, Gregers; Reeve, John Ch

    1997-01-01

    to revise assumptions regarding the basis of the method, which sometimes leads to the discovery of as-yet unnoticed phenomena. The present selection of automated methods for corrosion measurements is not motivated simply by the fact that a certain measurement can be performed automatically. Automation...... is applied to nearly all types of measurements today....

  6. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  7. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  8. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences.

    Science.gov (United States)

    van der Hoeven, Niels V; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A; van den Born, Bert-Jan H

    2013-11-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age (simultaneous and three sequential BP measurements were taken in each patient. Starting measurement type and starting arm for sequential measurements were randomized. Mean BP and inter-arm BP differences of the first pair and reproducibility of inter-arm BP differences of the first and second pair were compared between both methods. Mean systolic BP was 1.3±7.5 mm Hg lower during sequential compared with simultaneous measurement (Psequential measurement was on average higher than the second, suggesting an order effect. Absolute systolic inter-arm BP differences were smaller on simultaneous (6.2±6.7/3.3±3.5 mm Hg) compared with sequential BP measurement (7.8±7.3/4.6±5.6 mm Hg, PSimultaneous measurement of BP at both arms reduces order effects and results in smaller inter-arm BP differences, thereby potentially reducing unnecessary referral and diagnostic procedures. ©2013 Wiley Periodicals, Inc.

  9. Placental blood flow measurements with radioisotopes in the pregnant guinea pig

    International Nuclear Information System (INIS)

    Schmitt, R.; Giese, W.; Kurz, C.S.; Kuenzel, W.

    1976-01-01

    In 15 pregnant guinea pigs near term the blood flow (BF) of the myometrium and the placenta as well as the cardiac output were measured with 99 Tcsup(m)-labelled microspheres. In front of one placenta the clearance of 133 Xe was estimated in the same animal. For the 133 Xe measurement a theoretical concept is presented. The mean placental BF is 105ml/(minx100g)(SD:84) for 99 Tcsup(m) and 244(SD:80)ml/(minx100g) for 133 Xe. The difference in both flow values is assumed to be related to foetal placental BF. The placental blood flow is also related to the location of the placenta in the uterine horn. The ratio of myometrial blood flow to placental blood flow decreased with an increase in the mean arterial blood pressure. The measurements are a preliminary report of an attempt to compare two different methods in measuring placental blood flow. (author)

  10. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  11. Neonatal blood gas sampling methods | Goenka | South African ...

    African Journals Online (AJOL)

    There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual benefits and risks. This review critically surveys the available evidence to generate a comparison between arterial and capillary blood gas sampling, focusing on their ...

  12. Blood pressure measurement: one arm or both arm?

    Science.gov (United States)

    Kulkarni, Prasad K; Shekhar, Susheela; Reddy, B N; Nirmala, B C

    2011-09-01

    Guidelines for measuring blood pressure includes measurement of blood pressure on both arms but it is often ignored. Our case report aims at highlighting the need follow the guidelines. A 60 year old 59 kg weighing male asymptomatic patient without any comobidities was posted for bilateral inguinal hernia repair. The interarm blood pressure difference was discovered incidentally during his preanaesthetic evalution. On further evaluation patient was found to be having subclavian stenosis on left side which was asymptomatic. Intraoperative and post operative period was uneventful. Blood pressure measurement should be done in accordance with the stipulated guidelines. Inter arm blood pressure difference should be noted in all patients as not only for diagnosis and treatment of hypertension but also as a tool to diagnose asymptomatic peripheral vascular disesase.

  13. Channel box dimension measuring method

    International Nuclear Information System (INIS)

    Oshima, Hirotake; Jo, Hiroto.

    1994-01-01

    The present invention provides a method for measuring the entire length of a channel box of a fuel assembly of a BWR type reactor. Namely, four sensors are used as one set that generate ultrasonic waves from oblique upper portion, oblique lower portion, upper portion and lower portion of the channel box respectively. The distances between the four sensors and each of the portions of the channel box are measured respectively for both of a reference member and a member to be measured. The entire length of the channel box is measured by calculating the measured values and the angles of the obliquely disposed sensors according to a predetermined formula. According to the method of the present invention, the inclination of the channel box to be measured can be corrected. In addition, accuracy of the measurement is improved and the measuring time is saved as well as the measuring device and operation can be simplified. (I.S.)

  14. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  15. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  16. Optoacoustic measurements of human placenta and umbilical blood oxygenation

    Science.gov (United States)

    Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.

    2016-03-01

    Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.

  17. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    a reliable blood pressure reading. Results: We found that the patients did not adhere to given instructions when performing blood pressure self-measurement in the waiting room. None of the 81 patients adhered to all six inves- tigated recommendations, while around a quarter adhered to five out of six...

  18. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  19. MR measurement of coronary arterial blood flow velocity. Evaluation of age, stenosis and drugs as factors affecting coronary blood flow

    International Nuclear Information System (INIS)

    Taoka, Yoshiaki; Harada, Masafumi; Nishitani, Hiromu; Yukinaka, Michiko; Nomura, Masahiro

    1998-01-01

    Coronary arterial blood flow velocity was measured using MRI. Two types of phase contrast methods were used for the measurements, one of which exhibited good resolving power whereas the other provided more distinct images acquired while the subject patients held their breath. Before measuring coronary arterial blood flow velocity, accuracy of the two phase contrast methods was evaluated using a phantom. The results obtained with both methods largely agreed with the values obtained using the phantom. Using both methods, the patterns of coronary arterial blood flow over one cardiac cycle were essentially identical. A peak was noted in late systole or in early diastole in the right coronary artery, whereas in the left coronary artery, a peak was noted somewhat later in diastole. In healthy volunteers, no significant difference in the maximal flow velocity in the coronary arteries was found from one age group to another. Among patients with coronary arterial stenosis, coronary arterial blood flow velocity central to the area of stenosis was lower than that observed in the healthy volunteers. Coronary arterial blood flow velocity was observed to decrease after administration of isosorbide dinitrate and increased following administration of nifedipine. (author)

  20. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  1. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... is a valid method for assessing macular perfusion. Results were consistent with previous observations of hyperoxic blood flow reduction using blue field entoptic and laser Doppler velocimetry. Retinal perfusion seemed to be regulated around individual set points according to blood glucose levels. Multimodal...

  2. Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors.

    Science.gov (United States)

    Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun; Kobayashi, Yuka

    2016-12-28

    In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.

  3. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  4. Combination of phlebography and sanguinous measurement of venous blood pressure

    International Nuclear Information System (INIS)

    Weber, J.

    1988-01-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described. (orig.) [de

  5. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  6. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  7. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  8. High-speed video capillaroscopy method for imaging and evaluation of moving red blood cells

    Science.gov (United States)

    Gurov, Igor; Volkov, Mikhail; Margaryants, Nikita; Pimenov, Aleksei; Potemkin, Andrey

    2018-05-01

    The video capillaroscopy system with high image recording rate to resolve moving red blood cells with velocity up to 5 mm/s into a capillary is considered. Proposed procedures of the recorded video sequence processing allow evaluating spatial capillary area, capillary diameter and central line with high accuracy and reliability independently on properties of individual capillary. Two-dimensional inter frame procedure is applied to find lateral shift of neighbor images in the blood flow area with moving red blood cells and to measure directly the blood flow velocity along a capillary central line. The developed method opens new opportunities for biomedical diagnostics, particularly, due to long-time continuous monitoring of red blood cells velocity into capillary. Spatio-temporal representation of capillary blood flow is considered. Experimental results of direct measurement of blood flow velocity into separate capillary as well as capillary net are presented and discussed.

  9. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    Science.gov (United States)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  10. Measurement of Flow Properties of Mammalian Blood with Different Hematocrit Values Using Falling Needle Rheometer

    Directory of Open Access Journals (Sweden)

    Takamasa Suzuki

    2014-08-01

    Full Text Available The development of viscometry with high accuracy and quick operation, as well as the establishment of a data evaluation method by pathology are largely required. Especially, the flow properties of human blood are an important factor in the evaluation of blood disease on the medicine, but the method of viscometry and the data collection are not so easy. This study has been described on the viscosity measurement and their evaluations for mammalian blood (rabbit, pig and horse including human blood. A compact-sized falling needle rheometer (FNR and a flow analysis method using this device for blood have been developed, and the relationship between the apparent viscosity and physical properties (density, hematocrit value of blood have also been evaluated. Measured flow properties of blood are evaluated as a flow curve showing the relationship between the shear stress and shear rate. Observed flow curves of mammalian bloods show three typical fluid regions, these are, the Non-newtonian fluid region for a low shear rate range, the transition region and the Newtonian fluid region for a high shear rate range. Flow properties of blood in the Casson fluid region and the apparent viscosity (μ in the Newtonian fluid region are measured, and they are compared between mammals.

  11. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    Science.gov (United States)

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  12. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  13. Cerebral blood measurements in cerebral vascular disease: methodological and clinical aspects

    International Nuclear Information System (INIS)

    Fieschi, C.; Lenzi, G.L.

    1982-01-01

    This paper is devoted mainly to studies performed on acute cerebral vascular disease with the invasive techniques for the measurement of regional cerebral blood flow (rCBF). The principles of the rCBF method are outlined and the following techniques are described in detail: xenon-133 inhalation method, xenon-133 intravenous method and emission tomography methods. (C.F.)

  14. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  15. Hydrogen clearance: Assessment of technique for measurement of skin-flap blood flow in pigs

    International Nuclear Information System (INIS)

    Thomson, J.G.; Kerrigan, C.L.

    1991-01-01

    The hydrogen clearance technique has been used for many years by investigators to determine brain blood flow and has been partially validated in this setting using other methods of blood flow measurement. The method has been modified to allow blood flow measurements in skin, but the accuracy of H2 clearance for measuring skin blood flow has not been determined. Multiple blood flow measurements were performed using H2 clearance and radioactive microspheres on skin flaps and control skin in pigs. On 12 pigs, a total of 117 flap and 42 control skin measurements were available for analysis. There was no significant difference between the two techniques in measuring mean control skin blood flow. In skin flaps, H2 clearance was significantly correlated to microsphere-measured blood flow, but it consistently gave an overestimate. Sources of error may include injury to the tissues by insertion of electrodes, consumption of H2 by the electrodes, or diffusion of H2 from the relatively ischemic flap to its well-vascularized bed. Further studies are necessary to determine the cause of this error and to measure the technique's accuracy in skeletal muscle and other flaps

  16. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  17. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  18. Spectrometric kidney depth measurement method

    International Nuclear Information System (INIS)

    George, P.; Soussaline, F.; Raynaud, C.

    1976-01-01

    The method proposed uses the single posterior surface measurement of the kidney radioactivity distribution. The ratio C/P of the number of scattered photons to the number of primary photons, which is a function of the tissue depth penetrated, is calculated for a given region. The parameters on which the C/P value depends are determined from studies on phantoms. On the basis of these results the kidney depth was measured on a series of 13 patients and a correlation was established between the value thus calculated and that obtained by the profile method. The reproducibility of the method is satisfactory [fr

  19. Methods for Human Dehydration Measurement

    Science.gov (United States)

    Trenz, Florian; Weigel, Robert; Hagelauer, Amelie

    2018-03-01

    The aim of this article is to give a broad overview of current methods for the identification and quantification of the human dehydration level. Starting off from most common clinical setups, including vital parameters and general patients' appearance, more quantifiable results from chemical laboratory and electromagnetic measurement methods will be reviewed. Different analysis methods throughout the electromagnetic spectrum, ranging from direct current (DC) conductivity measurements up to neutron activation analysis (NAA), are discussed on the base of published results. Finally, promising technologies, which allow for an integration of a dehydration assessment system in a compact and portable way, will be spotted.

  20. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    Science.gov (United States)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  1. Measurements of vitamin B12 in human blood serum using resonance Raman spectroscopy

    Science.gov (United States)

    Tsiminis, G.; Schartner, E. P.; Brooks, J. L.; Hutchinson, M. R.

    2016-12-01

    Vitamin B12 (cobalamin and its derivatives) deficiency has been identified as a potential modifiable risk factor for dementia and Alzheimer's disease. Chronic deficiency of vitamin B12 has been significantly associated with an increased risk of cognitive decline. An effective and efficient method for measuring vitamin B12 concentration in human blood would enable ongoing tracking and assessment of this potential modifiable risk factor. In this work we present an optical sensor based on resonance Raman spectroscopy for rapid measurements of vitamin B12 in human blood serum. The measurement takes less than a minute and requires minimum preparation (centrifuging) of the collected blood samples.

  2. A simplified method for determination of radioactive iron in whole-blood samples

    DEFF Research Database (Denmark)

    Bukhave, Klaus; Sørensen, Anne Dorthe; Hansen, M.

    2001-01-01

    in humans. The overall recovery of radioiron from blood is more than 90%, and the coefficient of variation, as judged by the variation in the ratio Fe-55/Fe-59 is in the order of 4%. Combined with whole-body counting of 59Fe and direct gamma -counting of Fe-59 on blood samples, this method represents......For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method...... for simultaneous determination of Fe-55 and Fe-59 in blood, using a dry-ashing procedure and recrystallization of the remaining iron. The detection Limit of the method permits measurements of 0.1 Bq/ml blood thus allowing detection of Less than 1% absorption from a 40 kBq dose, which is ethically acceptable...

  3. Remote Blood Pressure Waveform Sensing Method and Apparatus

    National Research Council Canada - National Science Library

    Antonelli, Lynn T

    2008-01-01

    The invention as disclosed is a non-contact method and apparatus for continuously monitoring a physiological event in a human or animal, such as blood pressure, which involves utilizing a laser-based...

  4. Optimization of ciguatoxin extraction method from blood for Pacific ciguatoxin (P-CTX-1).

    Science.gov (United States)

    Bottein Dechraoui, Marie-Yasmine; Wang, Zhihong; Ramsdell, John S

    2007-01-01

    Ciguatera diagnosis relies on clinical observations associated with a recent consumption of fish. Although needed, direct confirmation of exposure in subjects showing ciguatera disease symptoms is currently unavailable. We previously reported that ciguatoxins were measurable in the blood of mice exposed to extracts of Pacific ciguatoxins isolated from Gambierdiscus polynesiensis, and of Indian Ocean or Caribbean Sea ciguatoxins, isolated from fish. Although highly efficient for extracting spiked purified Caribbean-CTX-1, the methanolic extraction method previously described is found here to yield only 6% recovery of spiked Pacific-CTX-1 (P-CTX-1). We report in this short communication a substantially modified method for ciguatoxin extraction from both dried and fresh blood. With this method, toxin measurement is directly accomplished in acetonitrile deproteinated whole fresh blood or phosphate buffer solution (PBS) eluted dried blood using the N2A cell-based assay. Spike studies using increasing concentrations of purified ciguatoxins reveal linear (r2 above 0.87 for all toxins) and overall efficient toxin recoveries (62%, 96%, and 96% from fresh blood and 75%, 90%, and 74% from dried blood, for C-CTX-1, P-CTX-3C, and P-CTX-1, respectively). Comparative blood matrix analysis for P-CTX-1 recovery shows increased recovery of ciguatoxin activity from whole fresh blood than from dried blood, greater by 20% in P-CTX-1 spiked mice blood and by over 85% in P-CTX-1 exposed mouse blood. In conclusion, both Caribbean and Pacific ciguatoxins can be readily extracted from blood using this modified method; however, in the case of P-CTX-1 we find that fresh blood is optimal.

  5. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Determining tumor blood flow parameters from dynamic image measurements

    Science.gov (United States)

    Libertini, Jessica M.

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth[l]. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community[2], this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake[3]. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  7. Results and validity of renal blood flow measurements using Xenon 133

    International Nuclear Information System (INIS)

    Serres, P.; Danet, B.; Guiraud, R.; Durand, D.; Ader, J.L.

    1975-01-01

    The renal blood flow was measured by external recording of the xenon 133 excretion curve. The study involved 45 patients with permanent high blood pressure and 7 transplant patients. The validity of the method was checked on 10 dogs. From the results it seems that the cortical blood flow, its fraction and the mean flow rate are the most representative of the renal haemodynamics parameters, from which may be established the repercussions of blood pressure on kidney vascularisation. Experiments are in progress on animals to check the compartment idea by comparing injections into the renal artery and into various kidney tissues in situ [fr

  8. Skeletal blood flow measured with /sup 18/F in patients with osteomalacia and hyperparathyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Tellez, M.; Wootton, R.; Reeve, J.

    1983-07-01

    Blood flow to bone was measured using the /sup 18/F clearance method described by Wootton et al. (1976) in osteomalacia (nine cases) and primary hyperparathyroidism (eight cases). Bone blood flow was elevated above normal in the osteomalacia group was normal in the hyperparathyroid group (range 3.6%-6.8% blood volume/min). It is suggested that bone blood flow is linked with the osteoblastic response of bone, and remains normal in cases of hyperparathyroidism when no clinical signs of bone involvement are present.

  9. Skeletal blood flow measured with 18F in patients with osteomalacia and hyperparathyroidism

    International Nuclear Information System (INIS)

    Tellez, M.; Wootton, R.; Reeve, J.

    1983-01-01

    Blood flow to bone was measured using the 18 F clearance method described by Wootton et al. (1976) in osteomalacia (nine cases) and primary hyperparathyroidism (eight cases). Bone blood flow was elevated above normal in the osteomalacia group was normal in the hyperparathyroid group (range 3.6%-6.8% blood volume/min). It is suggested that bone blood flow is linked with the osteoblastic response of bone, and remains normal in cases of hyperparathyroidism when no clinical signs of bone involvement are present. (orig.)

  10. Should blood pressure be measured with the cuff on a bare arm?

    NARCIS (Netherlands)

    Thien, T.; Keltjens, E.B.; Lenders, J.W.M.; Deinum, J.

    2015-01-01

    OBJECTIVE: To establish whether the results of blood pressure (BP) measurements are affected by wearing clothing underneath the BP cuff during measurement. METHODS: Normotensive and hypertensive patients (n=133; 65 men) of an outpatient clinic participated in this study. BP was measured according to

  11. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  12. Methods for the determination of skeletal muscle blood flow: development, strengths and limitations

    DEFF Research Database (Denmark)

    Gliemann, Lasse; Mortensen, Stefan P.; Hellsten, Ylva

    2018-01-01

    Since the first measurements of limb blood flow at rest and during nerve stimulation were conducted in the late 1800s, a number of methods have been developed for the determination of limb and skeletal muscle blood flow in humans. The methods, which have been applied in the study of aspects...... such as blood flow regulation, oxygen uptake and metabolism, differ in terms of strengths and degree of limitations but most have advantages for specific settings. The purpose of this review is to describe the origin and the basic principles of the methods, important aspects and requirements of the procedures....... One of the earliest methods, venous occlusion plethysmography, is a noninvasive method which still is extensively used and which provides similar values as other more direct blood flow methods such as ultrasound Doppler. The constant infusion thermodilution method remains the most appropriate...

  13. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  14. Cine-CT measurement of cortical renal blood flow

    International Nuclear Information System (INIS)

    Jaschke, W.R.; Gould, R.G.; Cogan, M.G.; Sievers, R.; Lipton, M.J.

    1987-01-01

    A modified indicator-dilution technique using radiographic contrast material and a cine-CT scanner was used to measure blood flow in the renal cortex of dogs. To validate this technique, CT measurements were correlated with simultaneous measurements of flow determined by radioactive microspheres. Measurements were taken during euvolemic conditions and after hemorrhage. Thirty-nine measurements were compared, covering a flow range from 1 to 7 ml min-1 g-1, and a good correlation was found between the cine-CT and microsphere results (r = 0.93; p less than 0.001). Additionally, cine-CT measurements were made of the mean transit time (MTT) of contrast material through the renal cortex, and the reciprocal of these MTT values was also well correlated to microsphere determined flow (r = 0.94; p less than 0.001). Thus, cine-CT appears to be a promising new technique for measuring renal blood flow

  15. Blood pressure measurement in epidemiological investigations in teenagers

    International Nuclear Information System (INIS)

    Coppieters, Yves; Parent, Florence; Berghmans, Luc; Godin, Isabelle; Leveque, Alain

    2001-01-01

    Background: The use of sphygmomanometers may lead to problems in investigations on health of young people. The purpose of this paper is to present the validation of the blood pressure (BP) collected during the survey 'Youth Heart Health' in Hainaut by using second sample of young people in Hainaut for which BP was measured by a manual taking of tension and by an electronic device. Methods: Validation was done with a control sample of 343 young with five successive BP measures: twice with the mercury sphygmomanometer and three with DXL. We compared the manual and the electronic measures in order to study the correlation between the two methods. The control sample was used in order to compare the BP measurements with the results of the survey on the health of young people in Hainaut. Results: The differences between manual systolic BP and Dinamap measures are significant (differences in averages 3.6 mmHg; d.s. 7.8; 95% CI: 2.8-4.4 mmHg; p < 0.001) and the regression coefficient is -0.015. Diastolic BP is significantly higher with the manual method than with Dinamap (differences in means: 8.2 mmHg; d.s. 7.0; 95% CI: 7.4-8.9 mmHg; p < 0.001) and the coefficient of regression is 0.096. We observe a difference in BP between the general survey and the control group (10.3 mmHg for systolic manual control and of 10.9 mmHg for systolic electronic control; 3.3 mmHg for diastolic manual control and of 11.5 mmHg for diastolic electronic control). Conclusions: The values of BP of the 'Youth Heart Health' are significantly higher. These observations indicate the difficulties in the choice of the tool for measurements of BP in epidemiological investigations in the teenagers. In order to decrease skews of observations in the measurement of BP, it is recommended to use a valid electronic instrument. Dinamap XL is an instrument of choice in such studies of young people. Environmental and organisational factors may also explain the observed difference, which means that survey

  16. Radiation protection, measurements and methods

    International Nuclear Information System (INIS)

    1983-06-01

    The introductory lectures discuss subjects such as radiation protection principles and appropriate measuring techniques; methods, quantities and units in radiation protection measurement; technical equipment; national and international radiation protection standards. The papers presented at the various sessions deal with: Dosimetry of external radiation (27 papers); Working environment monitoring and emission monitoring (21 contributions); Environmental monitoring (19 papers); Incorporation monitoring (9 papers); Detection limits (4 papers); Non-ionizing radiation, measurement of body dose and biological dosimetry (10 papers). All 94 contributions (lectures, compacts and posters) are retrievable as separate records. (HP) [de

  17. Noninvasive measurement of blood flow and extraction fraction

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-10-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen.

  18. Noninvasive measurement of blood flow and extraction fraction

    International Nuclear Information System (INIS)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-01-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen. (author)

  19. Preanalytical Biases in the Measurement of Human Blood Sphingolipids

    Directory of Open Access Journals (Sweden)

    Robert Brunkhorst

    2018-05-01

    Full Text Available Dysregulation of blood sphingolipids is an emerging topic in clinical science. The objective of this study was to determine preanalytical biases that typically occur in clinical and translational studies and that influence measured blood sphingolipid levels. Therefore, we collected blood samples from four healthy male volunteers to investigate the effect of storage conditions (time, temperature, long-term storage, freeze–thaw cycles, blood drawing (venous or arterial sampling, prolonged venous compression, and sample preparation (centrifugation, freezing on sphingolipid levels measured by LC-MS/MS. Our data show that sphingosine 1-phosphate (S1P and sphinganine 1-phosphate (SA1P were upregulated in whole blood samples in a time- and temperature-dependent manner. Increased centrifugation at higher speeds led to lower amounts of S1P and SA1P. All other preanalytical biases did not significantly alter the amounts of S1P and SA1P. Further, in almost all settings, we did not detect differences in (dihydroceramide levels. In summary, besides time-, temperature-, and centrifugation-dependent changes in S1P and SA1P levels, sphingolipids in blood remained stable under practically relevant preanalytical conditions.

  20. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  1. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  2. Measurement of endotoxin levels in blood of hemodialysis Patients by 'Lal' test and comparision of its efficacy with blood culture

    Directory of Open Access Journals (Sweden)

    Gh Vazirzadeh

    2006-01-01

    Full Text Available Introduction: Presently, bacteremia is the principal cause of morbidity in patients undergoing hemodialysis. Gram-negative bacteria account for approximately 50 percent of documented infections. Endotoxins released during lysis of gram negative bacteremia result in inflammatory and defense response by the body and if not treated promptly result in septic shock and ultimately death of the patient. This study describes the detection of endotoxins in blood of patients with bacteremia due to gram - negative bacteria by LAL test. Method: Blood samples of 278 hemodialysis patients were analyzed in this study and pathogens were isolated from blood culture samples. Then, their antibiotic sensitivity was determined. In patients with positive blood culture, endotoxin levels were measured by LAL-test. Results: Frequency of bacteremia in patients was 13.6% . The prevalence of gram – negative bacteremia was 44.7%. E coli were the major pathogens, while staphylococcus aureus was the most common gram positive bacterium. Endotoxin was detected in 15 patients (3.8 ± 1.08 EU/ml . The sensitivity and specificity of endotoxins for gram – negative bacteremia were 88% and 95%, respectively. Conclusion: The results indicate that the LAL method is a fast, sensitive and simple method. There was no significant difference between the results of blood culture and LAL – test ( P > 0.05 .

  3. Radiolabeled microsphere measurements of alveolar bone blood flow in dogs

    International Nuclear Information System (INIS)

    Kaplan, M.L.; Jeffcoat, M.K.; Goldhaber, P.

    1978-01-01

    Radiolabeled microspheres were injected into the left cardiac ventricle in healthy adult dogs to quantify blood in maxillary and mandibular alveolar bone. Heart rate, arterial blood pressure and pulse contour were monitored throughout each experiment. Blood flow in maxillary alveolar bone was more than 30 % greater (p<.001) than in mandibular alveolar bone. Alveolar bone blood flow (mean +- S.D.) measured as ml/min per gram was 0.12 +- .02 in the maxilla compared to 0.09 +- .02 in the mandible. The cardiovascular parameters monitored were constant immediately prior to the injection of microspheres and remained unchanged during and following injection. It is possible that radiolabeled microspheres can be used to quantify the circulatory changes in alveolar bone during the development of destructive periodontal disease in dogs. (author)

  4. A new method for detecting hemoglobin directly in whole blood using photon attenuation techniques

    International Nuclear Information System (INIS)

    Medhat, M.E.

    2014-01-01

    The objective of the proposed work is focused on measuring iron concentration directly in whole blood as tool for estimating hemoglobin and anemic conditions in patients across the world. The investigated method depends on theory of photon attenuation through transmission of low energy in whole blood sample. The mathematical expressions for calculating hemoglobin and iron deficit on blood using photon attenuation are derived. Calculations are carried out for estimating concentration of iron in blood samples taken from children, adults and old patients and therefore measuring their hemoglobin and iron deficit from normal values. Theoretical mass attenuation coefficient values were obtained using the XCOM program. A high-resolution gamma-ray spectrometry based on high purity germanium detector was employed to measure attenuation of strongly collimated monoenergetic gamma beam through blood samples. (author)

  5. Blood grouping based on PCR methods and agarose gel electrophoresis.

    Science.gov (United States)

    Sell, Ana Maria; Visentainer, Jeane Eliete Laguila

    2015-01-01

    The study of erythrocyte antigens continues to be an intense field of research, particularly after the development of molecular testing methods. More than 300 specificities have been described by the International Society for Blood Transfusion as belonging to 33 blood group systems. The polymerase chain reaction (PCR) is a central tool for red blood cells (RBC) genotyping. PCR and agarose gel electrophoresis are low cost, easy, and versatile in vitro methods for amplifying defined target DNA (RBC polymorphic region). Multiplex-PCR, AS-PCR (Specific Allele Polymerase Chain Reaction), and RFLP-PCR (Restriction Fragment Length Polymorphism-Polymerase Chain Reaction) techniques are usually to identify RBC polymorphisms. Furthermore, it is an easy methodology to implement. This chapter describes the PCR methodology and agarose gel electrophoresis to identify the polymorphisms of the Kell, Duffy, Kidd, and MNS blood group systems.

  6. A method for estimation of plasma albumin concentration from the buffering properties of whole blood

    DEFF Research Database (Denmark)

    Rees, Stephen Edward; Diemer, Tue; Kristensen, Søren Risom

    2012-01-01

    measurements of acid-base and oxygenation status. This article presents and evaluates a new method for doing so. MATERIALS AND METHODS: The mathematical method for estimating plasma albumin concentration is described. To evaluate the method at numerous albumin concentrations, blood from 19 healthy subjects......PURPOSE: Hypoalbuminemia is strongly associated with poor clinical outcome. Albumin is usually measured at the central laboratory rather than point of care, but in principle, information exists in the buffering properties of whole blood to estimate plasma albumin concentration from point of care...

  7. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  8. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  9. A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Itoh, Hiroshi; Bloomfield, P.M.; Munaka, Masahiro; Higano, Shuichi; Murakami, Matsutaro; Inugami, Atsushi; Eberl, S.; Aizawa, Yasuo; Kanno, Iwao; Uemura, Kazuo

    1994-01-01

    A method has been developed to quantitate regional cerebral blood blow (rCBF) using iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two single-photon emission tomography (SPET) scans and one blood sample. Based on a two-compartment model, radioactivity concentrations in the brain for each scan time are calculated. A standard input function has been generated by combining the input functions from 12 independent studies prior to this work to avoid frequent arterial blood sampling, and one blood sample is taken at 10 min following IMP administration for calibration of the standard arterial input function. This calibration time was determined such that the integration of the first 40 min of the calibrated, combined input function agreed best with those from 12 individual input functions (the difference was 5.3% on average). This method was applied to eight subjects (two normals and six patients with cerebral infarction), and yielded rCBF values which agreed well with those obtained by a positron emission tomography H 2 15 O autoradiography method. This method was also found to provide rCBF values that were consistent with those obtained by the non-linear least squares fitting technique and those obtained by conventional microsphere model analysis. The optimum SPET scan times were found to be 40 and 180 min for the early and delayed scans, respectively. These scan times allow the use of a conventional rotating gamma camera for clinical purposes. V d values ranged between 10 and 40 ml/g depending on the pathological condition, thereby suggesting the importance of measuring V d for each ROI. In conclusion, optimization of the blood sampling time and the scanning time enabled quantitative measurement of rCBF with two SPET scans and one blood sample. (orig.)

  10. A simple method for human peripheral blood monocyte Isolation

    Directory of Open Access Journals (Sweden)

    Marcos C de Almeida

    2000-04-01

    Full Text Available We describe a simple method using percoll gradient for isolation of highly enriched human monocytes. High numbers of fully functional cells are obtained from whole blood or buffy coat cells. The use of simple laboratory equipment and a relatively cheap reagent makes the described method a convenient approach to obtaining human monocytes.

  11. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  12. A RAPID Method for Blood Processing to Increase the Yield of Plasma Peptide Levels in Human Blood.

    Science.gov (United States)

    Teuffel, Pauline; Goebel-Stengel, Miriam; Hofmann, Tobias; Prinz, Philip; Scharner, Sophie; Körner, Jan L; Grötzinger, Carsten; Rose, Matthias; Klapp, Burghard F; Stengel, Andreas

    2016-04-28

    Research in the field of food intake regulation is gaining importance. This often includes the measurement of peptides regulating food intake. For the correct determination of a peptide's concentration, it should be stable during blood processing. However, this is not the case for several peptides which are quickly degraded by endogenous peptidases. Recently, we developed a blood processing method employing Reduced temperatures, Acidification, Protease inhibition, Isotopic exogenous controls and Dilution (RAPID) for the use in rats. Here, we have established this technique for the use in humans and investigated recovery, molecular form and circulating concentration of food intake regulatory hormones. The RAPID method significantly improved the recovery for (125)I-labeled somatostatin-28 (+39%), glucagon-like peptide-1 (+35%), acyl ghrelin and glucagon (+32%), insulin and kisspeptin (+29%), nesfatin-1 (+28%), leptin (+21%) and peptide YY3-36 (+19%) compared to standard processing (EDTA blood on ice, p processing, while after standard processing 62% of acyl ghrelin were degraded resulting in an earlier peak likely representing desacyl ghrelin. After RAPID processing the acyl/desacyl ghrelin ratio in blood of normal weight subjects was 1:3 compared to 1:23 following standard processing (p = 0.03). Also endogenous kisspeptin levels were higher after RAPID compared to standard processing (+99%, p = 0.02). The RAPID blood processing method can be used in humans, yields higher peptide levels and allows for assessment of the correct molecular form.

  13. Validation of curve-fitting method for blood retention of 99mTc-GSA. Comparison with blood sampling method

    International Nuclear Information System (INIS)

    Ha-Kawa, Sang Kil; Suga, Yutaka; Kouda, Katsuyasu; Ikeda, Koshi; Tanaka, Yoshimasa

    1997-01-01

    We investigated a curve-fitting method for the rate of blood retention of 99m Tc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent 99m Tc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of 99m Tc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1±2.1% (mean±standard deviation, n=77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5±6.1%, n=135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2±11.6%, n=13; vs. 31.9±2.8%, n=7, p 99m Tc-GSA and the plasma retention rate for indocyanine green (r=-0.869, p 99m Tc-GSA and could be a substitute for the blood sampling method. (author)

  14. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  15. Simultaneous compared with sequential blood pressure measurement results in smaller inter-arm blood pressure differences

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; Lodestijn, Sophie; Nanninga, Stephanie; van Montfrans, Gert A.; van den Born, Bert-Jan H.

    2013-01-01

    There are currently few recommendations on how to assess inter-arm blood pressure (BP) differences. The authors compared simultaneous with sequential measurement on mean BP, inter-arm BP differences, and within-visit reproducibility in 240 patients stratified according to age ( <50 or ≥60 years) and

  16. Cytokinesis-block micronucleus method in micro-blood cultures

    International Nuclear Information System (INIS)

    Liu Jinwen; Wang Lianzhi; Yang Cangzhen; Yao Yanyu

    1991-01-01

    This paper reports the cytokinesis-block micronucleus method in micro-blood cultures. The observations on detection induced micronuclei of different doses of 60 Co γ-rays irradiation and spontaneous micronucleus of different ages were performed with CB method in comporison with conventional micronucleus (CM) method. The results showed that with direct peripheral micro-blood cultures the cytoknesis-block micronuclei is also obtained. Using CB method, the micronuclei fequency of different ages was linear relationship, Y = 1.62 + 0.74 D, the spontaneous micronuclei frequency of different ages was 4.14%, the induced micronuclei also was a linear relationship, Y = 6.01 + 0.692 D. Using CM method, it showed that the induced micronuclei was a linear relationship, Y = 0.486 D - 1.968, but there is no significant difference between the micronuclei frequency of different ages. Comparison with CM and direct blood smear methods confirmed that the cytokinesis-block method of micro-blood cultures is more sensitive and precise

  17. Radioimmunoassay for measurement of thyroxine (T4) and triiodothyonine (T3) in blood serum

    International Nuclear Information System (INIS)

    Chopra, I.J.

    1975-01-01

    This invention relates to a highly accurate, rapid and simple estimation of thyroxine (T 4 ) directly from blood serum and also relates to the accurate measurement of triiodo-L-thyronine (T 3 ) directly from blood serum. More specifically, the invention relates to a rapid, specific and reliable radioimmunoassay (RIA) technique for measurement of both T 4 and T 3 in unextracted serum. The method requires very small amounts of serum, e.g., 25 microliters (μl) to measure T 4 concentration in nearly all specimens representing clinical states of eu-, hypo- and hyperthyroidism, and 250 μl to measure T 3 concentrations in specimens representing most clinical states

  18. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  19. Blood flow and blood volume in the femoral heads of healthy adults according to age. Measurement with positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Kubo, Toshikazu; Kimori, Kokuto; Nakamura, Fuminori; Inoue, Shigehiro; Fujioka, Mikihiro; Ueshima, Keiichiro; Hirasawa, Yasusuke; Ushijima, Yo; Nishimura, Tsunehiko

    2001-01-01

    To deepen understanding of hemodynamics in the femoral head, i.e., the essential factor in clarifying pathogenesis of hip disorders, this study examined blood flow and blood volume in the femoral heads of healthy adults, and their changes with age, by using positron emission tomography (PET). In 16 healthy adult males (age: 20-78 years old, mean age: 42 years), blood flow was measured by means of the H 2 15 O dynamic study method, and blood volume was measured by means of the 15 O-labeled carbon monoxide bolus inhalation method. Blood flow was 1.68-6.47 ml/min/100 g (mean ±SD: 3.52±1.2), and blood volume was 1.67-6.03 ml/100 g (mean ±SD: 3.00±1.27). Blood flow significantly decreased (p<0.01) with age, and blood volume significantly increased (P<0.05). PET was useful in the measurement of blood flow and blood volume in the femoral heads. With age, physiological hemodynamic changes also increased in femoral heads. (author)

  20. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    International Nuclear Information System (INIS)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F.

    2015-01-01

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length

  1. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  2. Simple technique for measuring relative renal blood flow

    International Nuclear Information System (INIS)

    Shames, D.M.; Korobkin, M.

    1976-01-01

    To determine whether externally monitored early renal uptake of 131 I-hippurate is proportional to renal blood flow, the renal uptake of 131 -hippurate at 1 to 2 min after injection was compared with the renal accumulation of radioactive carbonized microspheres in dogs. A renal artery catheter equipped with a balloon was used to decrease renal blood flow unilaterally. One minute after the intravenous injection of 100 μCi of 131 I-hippurate, about 1 μCi of either 85 Sr- or 95 Nb-labeled carbon microspheres was injected into the left ventricle. Radioactivity was measured over both kidneys. The total radioactivity within each kidney region of interest was corrected for background and integrated over the 1 to 2 min interval after injection. Thirteen measurements of relative renal blood flow were made for seven dogs. The dogs were then killed and both kidneys were excised and counted for the radioactivity of the microspheres. The 1 to 2-min relative renal uptake of 131 I-hippurate correlated well with relative microsphere uptake, suggesting that relative renal blood flow can be simply determined from the external measurements of renal uptake of 131 I-hippurate

  3. A simple technique to measure regional cerebral blood flow during intravascular ballon clamping

    International Nuclear Information System (INIS)

    Furuhata, Shigeru; Kubo, Atsushi; Kawase, Takeshi; Ibata, Yukio; Toya, Shigeo

    1988-01-01

    A case of giant internal carotid ophthalmic aneurysm was presented. In order to clarify whether the patient could tolerate carotid occlusion, a ballon clamping test was performed before surgery. The cerebral blood flow was measured using early imaging by single photon emission computed tomography (SPECT) with N-isopropyl-(iodine-123)-p-iodoamphetamine ( 123 I-IMP). When the ballon clamping test was performed the tracer was injected, and scanning was performed 35 minutes after removing the catheter. This tracer enabled a 'memory of blood flow' during temporary ischemia to determine the character of quick diffusion and slow wash out, that could not be performed by other methods of cerebral blood flow measurement. SPECT with 123 I-IMP can simplify the measurement of cerebral blood flow during the balloon clamping test. (author)

  4. Pulmonary blood flow distribution measured by radionuclide computed tomography

    International Nuclear Information System (INIS)

    Maeda, H.; Itoh, H.; Ishii, Y.

    1982-01-01

    Distributions of pulmonary blood flow per unit lung volume were measured in sitting patients with a radionuclide computed tomography (RCT) by intravenously administered Tc-99m macroaggregates of human serum albumin (MAA). Four different types of distribution were distinguished, among which a group referred as type 2 had a three zonal blood flow distribution as previously reported (West and co-workers, 1964). The pulmonary arterial pressure (Pa) and the venous pressure (Pv) were determined in this group of distribution. These values showed satifactory agreements with the pulmonary artery pressure (Par) and the capillary wedged pressure (Pcw) measured by Swan-Ganz catheter in eighteen supine patients. Those good correlations enable to establish a noninvasive methodology for measurement of pulmonary vascular pressures

  5. Adaptation of atomic spectrometric methods for the determination of trace elements in whole blood and blood fractions

    International Nuclear Information System (INIS)

    Prohaska, C.

    2002-05-01

    Analytical methods were developed and optimized for the determination of the elements Ca, Cr, Cu, Fe, Mg, Mn, Se, V and Zn in whole blood and in the blood fractions plasma, erythrocytes and lymphocytes of a group of people suffering from diabetes and of a control group of healthy individuals. Cr, Mn, Se and V were analyzed by ETAAS. Ca, Cu, Fe, Mg and Zn were analyzed by ICP-OES. The status of trace elements in lymphocytes of people suffering from diabetes is changed. Physiologically interesting correlations were observed between the clinical parameters cholesterol, HDL, LDL, blood glucose, HbA1c, age and BMI and the trace element concentrations, e.g. a correlation of blood glucose and HbA1c with selenium in whole blood. An ETAAS - method for the determination of Co and Mo was developed and optimized. The samples were digested applying a mixture of HNO3 and HF, different types of graphite furnaces were tested and a multiple injection technique was applied, thereby enabling a contribution to the normal values of these elements in human whole blood. An on-line coupling of a LC, controlled by FIA, with an ICP-OES was developed to investigate the concentrations of the iron species Fe(II) and Fe(III) and the copper species Cu(I) and Cu(II) in human blood plasma. The ICP-OES instrument was adapted, batch experiments were carried out, oxidizing and reducing agents were added and the acidity of the eluens, the flow rate and the integration time were optimized. Choosing alanine for complexation of the species of interest enables their separation under physiological conditions. In the real plasma samples measured most of the copper and iron was found in their oxidized forms. (author)

  6. A simple method for repetitive blood sampling of cattle

    African Journals Online (AJOL)

    thereby minimizing disturbance to the animal. As a pre- cautionary measure, animals received I 000 000 IV long-acting penicillin intramuscularly. Using this system, one assistant/researcher has successfully drawn blood from six cows concurrently at half hourly intervals for 48 h. To compare the degree of stress experienced.

  7. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length.

    Science.gov (United States)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu; Jiao, Shuliang; Zhang, Hao F

    2015-09-01

    Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as -0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31 μl/min among four wild-type rats. The authors' measured flow rates were consistent with results in the literature. By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  8. Measurement of regional hepatic blood flow by scintiphotosplenoportography

    Energy Technology Data Exchange (ETDEWEB)

    Kashiwagi, T; Kimura, K; Kamada, T; Abe, H [Osaka Univ. (Japan). Dept. of Radiology and Nuclear Medicine

    1978-08-01

    A new technique for estimating regional hepatic blood flow using the inert gas washout technique and scintillation camera following injection of /sup 133/Xe into the spleen is presented. This technique is easily, rapidly and repeatedly performed and permits the measurement of nutrient hepatic tissue blood flow. Measurement of regional hepatic blood flow in right and/or left lobes was performed in 28 patients. In all but one patient the right lobar flow value was equal to or greater than the left one. The right lobar flow was 86.20 +- 12.83 ml/100 gm/min in 3 patients without liver disease, 75.12 +- 14.54 ml/100 gm/min in 12 with chronic hepatitis and 51.24 +- 17.13 ml/100 gm/min in 11 with liver cirrhosis. This result suggests that hepatic tissue blood flow is significantly decreased in patients with liver cirrhosis. Scintillation camera images of initial xenon distribution in combination with monitor of washout curves over the liver also provide more information on the presence of extra- and intrahepatic shunts. Therefore, this technique appears to be clinically useful in evaluation of hemodynamic phenomena associated with liver diseases.

  9. Analysis of baseline, average, and longitudinally measured blood pressure data using linear mixed models.

    Science.gov (United States)

    Hossain, Ahmed; Beyene, Joseph

    2014-01-01

    This article compares baseline, average, and longitudinal data analysis methods for identifying genetic variants in genome-wide association study using the Genetic Analysis Workshop 18 data. We apply methods that include (a) linear mixed models with baseline measures, (b) random intercept linear mixed models with mean measures outcome, and (c) random intercept linear mixed models with longitudinal measurements. In the linear mixed models, covariates are included as fixed effects, whereas relatedness among individuals is incorporated as the variance-covariance structure of the random effect for the individuals. The overall strategy of applying linear mixed models decorrelate the data is based on Aulchenko et al.'s GRAMMAR. By analyzing systolic and diastolic blood pressure, which are used separately as outcomes, we compare the 3 methods in identifying a known genetic variant that is associated with blood pressure from chromosome 3 and simulated phenotype data. We also analyze the real phenotype data to illustrate the methods. We conclude that the linear mixed model with longitudinal measurements of diastolic blood pressure is the most accurate at identifying the known single-nucleotide polymorphism among the methods, but linear mixed models with baseline measures perform best with systolic blood pressure as the outcome.

  10. Method of inactivation of viral and bacterial blood contaminants

    International Nuclear Information System (INIS)

    Hackett, R.; Goodrich, R.P.; Van Borssum Waalkes, M.; Wong, V.A.

    1992-01-01

    A method is provided for inactivating viral and/or bacterial contamination in blood cellular matter, such as erythrocytes and platelets, or protein fractions. The cells or protein fractions are mixed with chemical sensitizers and irradiated with, for example, gamma or X-ray radiation

  11. Reliable blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, C. H.; Rasmussen, Niels H

    2014-01-01

    Background: Patients often fail to adhere to clinical recommendations when using current blood pressure self-measurement (BPSM) methods and equipment. As existing BPSM equipment is not able to detect non-adherent behavior, this could result in misdiagnosis and treatment error. To overcome...... patients scheduled for self-measuring their blood pressure (BP) in the waiting room at an obstetrics department's outpatient clinic to perform an additional BPSM using ValidAid. We then compared the automatically measured and classified values from ValidAid with our manual observations. Results: We found...

  12. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  13. Establishing traceability of photometric absorbance values for accurate measurements of the haemoglobin concentration in blood

    Science.gov (United States)

    Witt, K.; Wolf, H. U.; Heuck, C.; Kammel, M.; Kummrow, A.; Neukammer, J.

    2013-10-01

    Haemoglobin concentration in blood is one of the most frequently measured analytes in laboratory medicine. Reference and routine methods for the determination of the haemoglobin concentration in blood are based on the conversion of haeme, haemoglobin and haemiglobin species into uniform end products. The total haemoglobin concentration in blood is measured using the absorbance of the reaction products. Traceable absorbance measurement values on the highest metrological level are a prerequisite for the calibration and evaluation of procedures with respect to their suitability for routine measurements and their potential as reference measurement procedures. For this purpose, we describe a procedure to establish traceability of spectral absorbance measurements for the haemiglobincyanide (HiCN) method and for the alkaline haematin detergent (AHD) method. The latter is characterized by a higher stability of the reaction product. In addition, the toxic hazard of cyanide, which binds to the iron ion of the haem group and thus inhibits the oxygen transport, is avoided. Traceability is established at different wavelengths by applying total least-squares analysis to derive the conventional quantity values for the absorbance from the measured values. Extrapolation and interpolation are applied to get access to the spectral regions required to characterize the Q-absorption bands of the HiCN and AHD methods, respectively. For absorbance values between 0.3 and 1.8, the contributions of absorbance measurements to the total expanded uncertainties (95% level of confidence) of absorbance measurements range from 1% to 0.4%.

  14. Calibrated delivery drape versus indirect gravimetric technique for the measurement of blood loss after delivery: a randomized trial.

    Science.gov (United States)

    Ambardekar, Shubha; Shochet, Tara; Bracken, Hillary; Coyaji, Kurus; Winikoff, Beverly

    2014-08-15

    Trials of interventions for PPH prevention and treatment rely on different measurement methods for the quantification of blood loss and identification of PPH. This study's objective was to compare measures of blood loss obtained from two different measurement protocols frequently used in studies. Nine hundred women presenting for vaginal delivery were randomized to a direct method (a calibrated delivery drape) or an indirect method (a shallow bedpan placed below the buttocks and weighing the collected blood and blood-soaked gauze/pads). Blood loss was measured from immediately after delivery for at least one hour or until active bleeding stopped. Significantly greater mean blood loss was recorded by the direct than by the indirect measurement technique (253.9 mL and 195.3 mL, respectively; difference = 58.6 mL (95% CI: 31-86); p 500 mL (8.7% vs. 4.7%, p = 0.02). The study suggests a real and significant difference in blood loss measurement between these methods. Research using blood loss measurement as an endpoint needs to be interpreted taking measurement technique into consideration. This study has been registered at clinicaltrials.gov as NCT01885845.

  15. The measurement of blood speed in the pulmonary artery trunk

    Energy Technology Data Exchange (ETDEWEB)

    Saro, J P; Bula-Cruz, J [UTAD - 5000 Vila Real (Spain); Rafael, J A [Dep. Electronica e Telecomunicacoes da Univ. de Aveiro - 3800 Aveiro (Spain); Botelho, M F; Lima, J P [IBILI - Faculdade de Medicina da Univ. de Coimbra - 3000 Coimbra (Spain)

    1999-12-31

    The paper describes a non invasive methodology for the measurement of blood speed in the pulmonary artery trunk. The methodology has been tested with a moving radioactive tracer (nuclear medicine). An image processing technique is proposed, for detection and analysis of a moving object with variable shape and intensity over time (radioactive bolus). Experiments on the application of the technique in nuclear medicine are critically analysed. (authors) 9 refs., 7 figs.

  16. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Meindl, J. D.

    1975-01-01

    An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

  17. Noncontact blood species identification method based on spatially resolved near-infrared transmission spectroscopy

    Science.gov (United States)

    Zhang, Linna; Sun, Meixiu; Wang, Zhennan; Li, Hongxiao; Li, Yingxin; Li, Gang; Lin, Ling

    2017-09-01

    The inspection and identification of whole blood are crucially significant for import-export ports and inspection and quarantine departments. In our previous research, we proved Near-Infrared diffuse transmitted spectroscopy method was potential for noninvasively identifying three blood species, including macaque, human and mouse, with samples measured in the cuvettes. However, in open sampling cases, inspectors may be endangered by virulence factors in blood samples. In this paper, we explored the noncontact measurement for classification, with blood samples measured in the vacuum blood vessels. Spatially resolved near-infrared spectroscopy was used to improve the prediction accuracy. Results showed that the prediction accuracy of the model built with nine detection points was more than 90% in identification between all five species, including chicken, goat, macaque, pig and rat, far better than the performance of the model built with single-point spectra. The results fully supported the idea that spatially resolved near-infrared spectroscopy method can improve the prediction ability, and demonstrated the feasibility of this method for noncontact blood species identification in practical applications.

  18. Transcutaneous Measurement of Blood Analyte Concentration Using Raman Spectroscopy

    Science.gov (United States)

    Barman, Ishan; Singh, Gajendra P.; Dasari, Ramachandra R.; Feld, Michael S.

    2008-11-01

    Diabetes mellitus is a chronic disorder, affecting nearly 200 million people worldwide. Acute complications, such as hypoglycemia, cardiovascular disease and retinal damage, may occur if the disease is not adequately controlled. As diabetes has no known cure, tight control of glucose levels is critical for the prevention of such complications. Given the necessity for regular monitoring of blood glucose, development of non-invasive glucose detection devices is essential to improve the quality of life in diabetic patients. The commercially available glucose sensors measure the interstitial fluid glucose by electrochemical detection. However, these sensors have severe limitations, primarily related to their invasive nature and lack of stability. This necessitates the development of a truly non-invasive glucose detection technique. NIR Raman Spectroscopy, which combines the substantial penetration depth of NIR light with the excellent chemical specificity of Raman spectroscopy, provides an excellent tool to meet the challenges involved. Additionally, it enables simultaneous determination of multiple blood analytes. Our laboratory has pioneered the use of Raman spectroscopy for blood analytes' detection in biological media. The preliminary success of our non-invasive glucose measurements both in vitro (such as in serum and blood) and in vivo has provided the foundation for the development of feasible clinical systems. However, successful application of this technology still faces a few hurdles, highlighted by the problems of tissue luminescence and selection of appropriate reference concentration. In this article we explore possible avenues to overcome these challenges so that prospective prediction accuracy of blood analytes can be brought to clinically acceptable levels.

  19. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Walsh Michael

    2010-06-01

    Full Text Available Abstract Background Left ventricular (LV hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. Methods This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month. Agreement was assessed using Lin's concordance correlation coefficient (CCC and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC. Results Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80 predictive power for LV hypertrophy. Conclusions A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  20. Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow

    International Nuclear Information System (INIS)

    Swiontkowski, M.F.; Tepic, S.; Perren, S.M.; Moor, R.; Ganz, R.; Rahn, B.A.

    1986-01-01

    Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and 85 Sr-labeled microspheres were made in an adult rabbit model. There was no correlation between the two methods for blood flow in the femoral condyles and the correlation between the two methods for blood flow in the femoral head does not achieve statistical significance. An LDF signal of 0.4 V was approximately equal to a microsphere measured flow rate of 0.4 ml blood/g bone/min. The strength of the correlation in the latter case may have been affected by (a) large arteriovenous shunts, (b) inadequate mixing of the microspheres with a left ventricular injection, and (c) insufficient numbers of microspheres present in the bone samples. When LDF was used to evaluate the effect of elevated intracapsular pressure on femoral head blood flow in skeletally mature rabbits, femoral head subchondral bone blood flow declined with increasing intracapsular pressure from a baseline value of 0.343 +/- 0.036 to a value of 0.127 +/- 0.27 at 120 cm of water pressure. The decline in femoral head blood flow was statistically significant at pressures of 40 cm of water or higher (p less than 0.001), and evaluation of sections of the proximal femora made from preterminal disulphine blue injections confirmed these findings. Intracapsular tamponade has an adverse effect on femoral head blood flow beginning well below central venous pressure and should be considered in the pathophysiology of posttraumatic and nontraumatic necrosis of the femoral head. Laser Doppler flowmetry was easy to use and appears to be a reproducible technique for evaluating femoral head blood flow, offering distinct advantages over the microsphere technique for measuring bone blood flow

  1. Single-cell measurement of red blood cell oxygen affinity.

    Science.gov (United States)

    Di Caprio, Giuseppe; Stokes, Chris; Higgins, John M; Schonbrun, Ethan

    2015-08-11

    Oxygen is transported throughout the body by hemoglobin (Hb) in red blood cells (RBCs). Although the oxygen affinity of blood is well-understood and routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of RBC volume and Hb concentration are taken millions of times per day by clinical hematology analyzers, and they are important factors in determining the health of the hematologic system. To better understand the variability and determinants of oxygen affinity on a cellular level, we have developed a system that quantifies the oxygen saturation, cell volume, and Hb concentration for individual RBCs in high throughput. We find that the variability in single-cell saturation peaks at an oxygen partial pressure of 2.9%, which corresponds to the maximum slope of the oxygen-Hb dissociation curve. In addition, single-cell oxygen affinity is positively correlated with Hb concentration but independent of osmolarity, which suggests variation in the Hb to 2,3-diphosphoglycerate (2-3 DPG) ratio on a cellular level. By quantifying the functional behavior of a cellular population, our system adds a dimension to blood cell analysis and other measurements of single-cell variability.

  2. Renewable energy: Method and measures

    International Nuclear Information System (INIS)

    Nilsen, Trond Hartvedt

    2003-01-01

    The thesis presents various possibilities for renewable energy in Norway. The wind power would give a practical and economic alternative. The external costs for the wind power would be moderate. In chapter 3 the utility cost analysis for renewable alternatives are studied relative to the macroeconomic efficiency. Some methodical problems and how these analyses are used are reviewed. In the practical utility cost analyses wind power is studied relative to gas power which is the non-renewable alternative present in Norway today. A qualitative part is included. It is not possible to determine whether wind power is preferable to gas power in the macroeconomic perspective. Wind power would be the choice if high environmental and CO2 cleaning costs are expected. The first conclusion to be drawn is that it is difficult to decide whether wind power is the best solution based on cost benefit analysis. However, the alternative seems to be quite robust in the analysis. Due to the central position the energy supplies have in the society this business should be heavily regulated. The sector is also overtaxed as a reduction in consumption is desired. The analysis shows that the system does not function perfectly. The thesis surveys various measures for improving the renewable energy supply and focuses on the wind power. A model for and analysis of the measures are carried out and resulted in a second conclusion. The measures have various properties as to the influence on the market. A subsidy is a fine measure for stimulation production of green power while a tax reduces efficiently the production of black power. A system with green licenses in combination with a subsidy and a tax would be preferable as to increasing the part of renewable energy of the total production. It is therefore necessary to have clearly defined goals and use suitable measures for achieving them. The costs of wind power is falling and it would therefore soon be macroeconomic profitable. It is also

  3. Method of measuring surface density

    International Nuclear Information System (INIS)

    Gregor, J.

    1982-01-01

    A method is described of measuring surface density or thickness, preferably of coating layers, using radiation emitted by a suitable radionuclide, e.g., 241 Am. The radiation impinges on the measured material, e.g., a copper foil and in dependence on its surface density or thickness part of the flux of impinging radiation is reflected and part penetrates through the material. The radiation which has penetrated through the material excites in a replaceable adjustable backing characteristic radiation of an energy close to that of the impinging radiation (within +-30 keV). Part of the flux of the characteristic radiation spreads back to the detector, penetrates through the material in which in dependence on surface density or thickness of the coating layer it is partly absorbed. The flux of the penetrated characteristic radiation impinging on the face of the detector is a function of surface density or thickness. Only that part of the energy is evaluated of the energy spectrum which corresponds to the energy of characteristic radiation. (B.S.)

  4. Regional cerebral blood flow measurement using a scintillation camera

    International Nuclear Information System (INIS)

    Heiss, W.D.

    1979-01-01

    A scintillation camera connected to auxillary equipment with off-line data processing or connected to an on-line dedicated computer system permits measurement of hemispheric and regional cerebral blood flow. Reliable flow values are obtained from regions limited in size by spatial resolution and the count rates achieved. Flow measurements obtained with the camera are able to resolve inhomogeneities of cerebral circulation in normal subjects. In a variety of clinical conditions, the localization, severity and extent of flow alterations are shown. Results of flow measurements in individual cases elucidate the pathogenesis of neurologic deficits, quantify the damage to the brain, indicate therapeutic measures of potential value and permit an estimation of the further clinical course. With restricted spatial resolution, flow measurements after intravenous 133 Xe injection are also feasible

  5. Distribution of the pulmonary blood flow measured by ECT

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, H.; Itoh, H.; Todo, Y.; Ishii, Y.; Mukai, T. (Kyoto Univ. (Japan). Hospital)

    1981-05-01

    Distributions of pulmonary blood flow per unit lung volume were observed by using the combination of Tc-99m-MAA and radionuclide CT. Administration of Tc-99m-MAA to the patients were performed in sitting position. Ten patients were studied with this method. In nine patients, the blood flow distribution was greater in the direction of the gravity, namely, more blood flow in the lower than the upper lung region. In six patients were demonstrated the relation between blood flow and the vertical distance described by West et al. Thus, it was possible to evaluate the arterial and venous pressures of the lung with the estimated pressure of 4.15 +- 1.93 cmH/sub 2/O and -5.55 +- 2.48 cmH/sub 2/O in relation to the angle of Louis. The agreement was reasonably well with that reported by Butler and Paley. Three patients had pulmonary hypertension with the distribution of monotonous increase, of which slope was similar to that of zone III in other six patients. The last patient with COPD had quite different distribution from other nine patients.

  6. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    Science.gov (United States)

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  7. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis.

    Science.gov (United States)

    Khangura, Jaspreet; Culleton, Bruce F; Manns, Braden J; Zhang, Jianguo; Barnieh, Lianne; Walsh, Michael; Klarenbach, Scott W; Tonelli, Marcello; Sarna, Magdalena; Hemmelgarn, Brenda R

    2010-06-24

    Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  8. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...... of the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77......% of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two of ten...

  9. Evaluation of a method for determination of the subcutaneous blood flow in the forefoot continuously over 24 h

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Bülow, J

    1984-01-01

    A method is presented which allows for continuous registration of forefoot blood flow over 24 h. Blood flow was estimated by the radioactive Xenon washout method and a portable CdTe detector system was used to measure the tracer disappearance rate. Since the semiconductor detector is placed very ...

  10. First measurement of radon transfer. Water - skin - blood - air

    International Nuclear Information System (INIS)

    Philipsborn, H. von; Grunewald, W.A.

    2000-01-01

    While radon is disliked in uranium mines and homes, it is used medically in radon spas for the treatment of several ailments. The transfer of radon gas from water, through skin into blood and into expiratory air was studied completely for the first time for a person resting 20-30 min in radon water. For waterborne radon concentrations of 1500±100 Bq/L, 4±1 Bq/L were measured in the blood and 2.4±0.5 kBq/m 3 (Bq/L) in the expiratory air. The results can be understood according to the principles of physiology. The nature of the experiments excluded persons other than the authors. Hence the study has been radiometric (physical), not clinical (medical). (orig.)

  11. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  12. Four-Parameter white blood cell differential counting based on light scattering measurements

    NARCIS (Netherlands)

    Terstappen, Leonardus Wendelinus Mathias Marie; de Grooth, B.G.; Visscher, K.; Kouterik, F.A.; Greve, Jan

    1988-01-01

    Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinephilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped

  13. Definition, significance and measurement of quantities pertaining to the oxygen carrying properties of human blood

    NARCIS (Netherlands)

    Zijlstra, WG; Maas, AHJ; Moran, RF

    1996-01-01

    A consistent set of definitions is given of the principal quantities pertaining to the oxygen transport by the blood, and of their mutual relationships, in relation to the methods used in their measurement. At the core is the correct definition of oxygen saturation, the deviation of which has

  14. Automated Methods Of Corrosion Measurements

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; Andersen, Jens Enevold Thaulov; Reeve, John Ch

    1997-01-01

    The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell.......The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell....

  15. Hepatitis B Virus Blood Screening: Need for Reappraisal of Blood Safety Measures?

    Directory of Open Access Journals (Sweden)

    Daniel Candotti

    2018-02-01

    Full Text Available Over the past decades, the risk of HBV transfusion–transmission has been steadily reduced through the recruitment of volunteer donors, the selection of donors based on risk-behavior evaluation, the development of increasingly more sensitive hepatitis B antigen (HBsAg assays, the use of hepatitis B core antibody (anti-HBc screening in some low-endemic countries, and the recent implementation of HBV nucleic acid testing (NAT. Despite this accumulation of blood safety measures, the desirable zero risk goal has yet to be achieved. The residual risk of HBV transfusion–transmission appears associated with the preseroconversion window period and occult HBV infection characterized by the absence of detectable HBsAg and extremely low levels of HBV DNA. Infected donations tested false-negative with serology and/or NAT still persist and derived blood components were shown to transmit the virus, although rarely. Questions regarding the apparent redundancy of some safety measures prompted debates on how to reduce the cost of HBV blood screening. In particular, accumulating data strongly suggests that HBsAg testing may add little, if any HBV risk reduction value when HBV NAT and anti-HBc screening also apply. Absence or minimal acceptable infectious risk needs to be assessed before considering discontinuing HBsAg. Nevertheless, HBsAg remains essential in high-endemic settings where anti-HBc testing cannot be implemented without compromising blood availability. HBV screening strategy should be decided according to local epidemiology, estimate of the infectious risk, and resources.

  16. Red blood cell-deformability measurement: review of techniques.

    Science.gov (United States)

    Musielak, M

    2009-01-01

    Cell-deformability characterization involves general measurement of highly complex relationships between cell biology and physical forces to which the cell is subjected. The review takes account of the modern technical solutions simulating the action of the force applied to the red blood cell in macro- and microcirculation. Diffraction ektacytometers and rheoscopes measure the mean deformability value for the total red blood cell population investigated and the deformation distribution index of individual cells, respectively. Deformation assays of a whole single cell are possible by means of optical tweezers. The single cell-measuring setups for micropipette aspiration and atomic force microscopy allow conducting a selective investigation of deformation parameters (e.g., cytoplasm viscosity, viscoelastic membrane properties). The distinction between instrument sensitivity to various RBC-rheological features as well as the influence of temperature on measurement are discussed. The reports quoted confront fascinating possibilities of the techniques with their medical applications since the RBC-deformability has the key position in the etiology of a wide range of conditions.

  17. Noninvasive measurement of nutrient portal blood shunting: an experimental study with [14C]ursodeoxycholic acid

    International Nuclear Information System (INIS)

    Nordlinger, B.; Parquet, M.; Infante, R.; Moreels, R.; Blondiau, P.; Boschat, M.; Groussard, M.; Huguet, C.

    1982-01-01

    All of the methods proposed for measuring portal blood flow are either invasive, estimate total rather than nutrient flow, and none has proved reliable in cirrhotic patients. A method has been derived from pharmacokinetic principles used for the calculation of bioavailability of drugs according to the route of administration (i.v. or p.o.) and tested experimentally in 20 pigs. A tracer dose of [ 14 C]ursodeoxycholic acid, a biliary acid with a high-liver first-pass effect, is administered in the duodenum, and serial peripheral blood samples are taken. Later, the same dose of the same drug is administered i.v. The shunt fraction of portal blood F is obtained by the ratio of the areas under the plasma level vs. time curves (AUC) after p.o. and i.v. administrations: (see formula in text). The pigs were divided into three experimental groups. (i) Group I: undisturbed portal flow; (ii) Group II: total diversion of portal blood with an end-to-side portacaval shunt, and (iii) Group III: partial diversion of portal blood through a side-to-side portacaval shunt. Portal flow was measured during surgery with an electromagnetic flowmeter above and below the shunt and the degree of shunting calculated. Results show that the shunt fraction measured with ursodeoxycholic acid is well-correlated with hemodynamic data. No overlap between Groups I and III is observed. It is concluded that the shunt fraction of nutrient portal blood can be measured with this noninvasive method. Minute amounts of ursodeoxycholic acid were used in order to be completely metabolized by the liver, even in spite of hepatocellular dysfunction. Therefore, this method should be valid in cirrhotic patients and be useful to decide the type of portasystemic shunt to propose for the decompression of gastroesophageal varices

  18. Reduction in requirements for allogeneic blood products: nonpharmacologic methods.

    Science.gov (United States)

    Hardy, J F; Bélisle, S; Janvier, G; Samama, M

    1996-12-01

    Various strategies have been proposed to decrease bleeding and allogeneic transfusion requirements during and after cardiac operations. This article attempts to document the usefulness, or lack thereof, of the nonpharmacologic methods available in clinical practice. Blood conservation methods were reviewed in chronologic order, as they become available to patients during the perisurgical period. The literature in support of or against each strategy was reexamined critically. Avoidance of preoperative anemia and adherence to published guidelines for the practice of transfusion are of paramount importance. Intraoperatively, tolerance of low hemoglobin concentrations and use of autologous blood (predonated or harvested before bypass) will reduce allogeneic transfusions. The usefulness of plateletpheresis and retransfusion of shed mediastinal fluid remains controversial. Intraoperatively and postoperatively, maintenance of normothermia contributes to improved hemostasis. Several approaches have been shown to be effective. An efficient combination of methods can reduce, and sometimes abolish, the need for allogeneic blood products after cardiac operations, inasmuch as all those involved in the care of cardiac surgical patients adhere thoughtfully to existing transfusion guidelines.

  19. Reference measurement procedure for the determination of electrolytes in human blood via ICP-OES measurement

    Science.gov (United States)

    Grote-Koska, D.; Klauke, R.; Brand, K.; Schumann, G.

    2018-04-01

    The determination of electrolytes in human body fluids is one of the most frequently performed analyses in clinical routine laboratories. Metrological traceability of measurement results in patient samples is essential and requires the involvement of higher order reference measurement procedures wherever available. Here, the authors present the evaluation of a higher order reference system for the simultaneous determination of K+, Li+, Na+, Ca2+ and Mg2+ in blood serum and plasma. In the same order, the determined measurement performances were as follows: measurement ranges: 0.75 mmol l-1-75.0 mmol l-1, 0.05 mmol l-1-5.00 mmol l-1, 5 mmol l-1-200 mmol l-1, 0.4 mmol l-1-8.0 mmol l-1 and 0.1 mmol l-1-4.0 mmol l-1. Measurement imprecision: CVs were  ⩽1.1% for intra assay investigations and  ⩽1.8% for long term inter assay investigations for all measurands. Excellent accuracy was found testing certified Standard Reference Materials from NIST: SRM 909 (deviations from 0.0% to 1.1%) and SRM 956 (deviations from 0.0% to 1.5%). Intercomparisons with the German Metrology Institute (PTB) revealed differences from 0.1% to 0.8%. Matrix influences and carry over were not detectable. The expanded combined measurement uncertainties for the determination of the reference method values were estimated as  ⩾1.5% (k  =  2) for each measurand. The reference measurement procedure is accredited by the German accreditation body (DAkkS) in association with the German calibration service (DKD) according to ISO 17025 and ISO 15195. Services comprise the certification of calibrators, control materials and samples used in proficiency testing schemes.

  20. Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First- Morning Micturition and in the Afternoon

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Monteiro de Almeida

    2014-10-01

    Full Text Available Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM. Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM as gold-standard and measurements taken before morning micturition (BM and in the afternoon (AM, for the best diagnosis of systemic arterial hypertension (SAH, and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM; and with post-morning-micturition and evening measurements (PM+EM. All patients underwent echocardiography (for left ventricular hypertrophy - LVH and urinary albumin measurement (for microalbuminuria - MAU. Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM and (PM+EM, and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM versus (PM+EM were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM and (PM+EM were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

  1. Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse

    Science.gov (United States)

    Adair, Henry S., III

    1998-07-01

    Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.

  2. Out-of-office blood pressure: from measurement to control

    Directory of Open Access Journals (Sweden)

    Baguet JP

    2012-05-01

    Full Text Available Jean-Philippe Baguet1,21Department of Cardiology, University Hospital, 2Bioclinic Radiopharmaceutics Laboratory, INSERM U1039, Joseph Fourier University, Grenoble, FranceAbstract: Hypertension is an important risk factor for the development of cardiovascular disease, and is a major cause of morbidity and mortality worldwide. Traditionally, hypertension diagnosis and treatment and clinical evaluations of antihypertensive efficacy have been based on office blood pressure (BP measurements; however, there is increasing evidence that office measures may provide inadequate or misleading estimates of a patient’s true BP status and level of cardiovascular risk. The introduction, and endorsement by treatment guidelines, of 24-hour ambulatory BP monitoring and self (or home BP monitoring has facilitated more reliable and reproducible estimations of true BP, including the identification of white-coat and masked hypertension, and evaluation of BP variability. In addition, ambulatory BP monitoring enables accurate assessment of treatment effectiveness over 24 hours and both ambulatory and self BP monitoring may lead to better tailoring of therapy according to BP profile and concomitant disease. This review describes the clinical benefits and limitations of out-of-office assessments and their applications for effective management of hypertension and attainment of BP control.Keywords: ambulatory, ABPM, SBPM, blood pressure measurement, hypertension

  3. Rotating permanent magnet excitation for blood flow measurement.

    Science.gov (United States)

    Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S

    2015-11-01

    A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

  4. Common Genetic Polymorphisms Influence Blood Biomarker Measurements in COPD

    Science.gov (United States)

    Drummond, M. Bradley; Hawkins, Gregory A.; Yang, Jenny; Chen, Ting-huei; Quibrera, Pedro Miguel; Anderson, Wayne; Barr, R. Graham; Bleecker, Eugene R.; Beaty, Terri; Casaburi, Richard; Castaldi, Peter; Cho, Michael H.; Comellas, Alejandro; Crapo, James D.; Criner, Gerard; Demeo, Dawn; Christenson, Stephanie A.; Couper, David J.; Doerschuk, Claire M.; Freeman, Christine M.; Gouskova, Natalia A.; Han, MeiLan K.; Hanania, Nicola A.; Hansel, Nadia N.; Hersh, Craig P.; Hoffman, Eric A.; Kaner, Robert J.; Kanner, Richard E.; Kleerup, Eric C.; Lutz, Sharon; Martinez, Fernando J.; Meyers, Deborah A.; Peters, Stephen P.; Regan, Elizabeth A.; Rennard, Stephen I.; Scholand, Mary Beth; Silverman, Edwin K.; Woodruff, Prescott G.; O’Neal, Wanda K.; Bowler, Russell P.

    2016-01-01

    Implementing precision medicine for complex diseases such as chronic obstructive lung disease (COPD) will require extensive use of biomarkers and an in-depth understanding of how genetic, epigenetic, and environmental variations contribute to phenotypic diversity and disease progression. A meta-analysis from two large cohorts of current and former smokers with and without COPD [SPIROMICS (N = 750); COPDGene (N = 590)] was used to identify single nucleotide polymorphisms (SNPs) associated with measurement of 88 blood proteins (protein quantitative trait loci; pQTLs). PQTLs consistently replicated between the two cohorts. Features of pQTLs were compared to previously reported expression QTLs (eQTLs). Inference of causal relations of pQTL genotypes, biomarker measurements, and four clinical COPD phenotypes (airflow obstruction, emphysema, exacerbation history, and chronic bronchitis) were explored using conditional independence tests. We identified 527 highly significant (p 10% of measured variation in 13 protein biomarkers, with a single SNP (rs7041; p = 10−392) explaining 71%-75% of the measured variation in vitamin D binding protein (gene = GC). Some of these pQTLs [e.g., pQTLs for VDBP, sRAGE (gene = AGER), surfactant protein D (gene = SFTPD), and TNFRSF10C] have been previously associated with COPD phenotypes. Most pQTLs were local (cis), but distant (trans) pQTL SNPs in the ABO blood group locus were the top pQTL SNPs for five proteins. The inclusion of pQTL SNPs improved the clinical predictive value for the established association of sRAGE and emphysema, and the explanation of variance (R2) for emphysema improved from 0.3 to 0.4 when the pQTL SNP was included in the model along with clinical covariates. Causal modeling provided insight into specific pQTL-disease relationships for airflow obstruction and emphysema. In conclusion, given the frequency of highly significant local pQTLs, the large amount of variance potentially explained by pQTL, and the

  5. Common Genetic Polymorphisms Influence Blood Biomarker Measurements in COPD.

    Directory of Open Access Journals (Sweden)

    Wei Sun

    2016-08-01

    Full Text Available Implementing precision medicine for complex diseases such as chronic obstructive lung disease (COPD will require extensive use of biomarkers and an in-depth understanding of how genetic, epigenetic, and environmental variations contribute to phenotypic diversity and disease progression. A meta-analysis from two large cohorts of current and former smokers with and without COPD [SPIROMICS (N = 750; COPDGene (N = 590] was used to identify single nucleotide polymorphisms (SNPs associated with measurement of 88 blood proteins (protein quantitative trait loci; pQTLs. PQTLs consistently replicated between the two cohorts. Features of pQTLs were compared to previously reported expression QTLs (eQTLs. Inference of causal relations of pQTL genotypes, biomarker measurements, and four clinical COPD phenotypes (airflow obstruction, emphysema, exacerbation history, and chronic bronchitis were explored using conditional independence tests. We identified 527 highly significant (p 10% of measured variation in 13 protein biomarkers, with a single SNP (rs7041; p = 10-392 explaining 71%-75% of the measured variation in vitamin D binding protein (gene = GC. Some of these pQTLs [e.g., pQTLs for VDBP, sRAGE (gene = AGER, surfactant protein D (gene = SFTPD, and TNFRSF10C] have been previously associated with COPD phenotypes. Most pQTLs were local (cis, but distant (trans pQTL SNPs in the ABO blood group locus were the top pQTL SNPs for five proteins. The inclusion of pQTL SNPs improved the clinical predictive value for the established association of sRAGE and emphysema, and the explanation of variance (R2 for emphysema improved from 0.3 to 0.4 when the pQTL SNP was included in the model along with clinical covariates. Causal modeling provided insight into specific pQTL-disease relationships for airflow obstruction and emphysema. In conclusion, given the frequency of highly significant local pQTLs, the large amount of variance potentially explained by pQTL, and the

  6. Principles of the tracer method in assessing regional blood flow

    International Nuclear Information System (INIS)

    Potchen, E.J.; Siegel, B.; Meidinger, R.

    1972-01-01

    The standard brain scan is abnormal when there is relative increase in blood volume or when there is an abnormal permeability to substances which normally cannot enter the brain tissue. The usual mechanism of abnormal permeability is based upon neovascularity in tissues which do not maintain the tight junctions one sees in the normal brain endothelium. These tight junctions prohibit the leakage of materials from the intra- to extravascular space, and when they are not available many materials can readily transit into the abnormal tissue substance and can therefore be discerned on a standard brain scan. In many instances, however, there is no gross breakdown in this blood-brain barrier, but more subtle derangement may be detected by determining changes in regional brain blood volume or the relative volume of distribution of various labeled materials. We have studied whether or not we can discern differences in brain spaces of two isotopes in experimental situations where the brain scan would be normal. For these models, we have used water-induced brain edema and triethyl-tin-induced brain edema in the experimental animal. In water intoxication, there is no difference in the microvascular anatomy or change in the 99 /sup m/Tc pertechnetate space, but it is apparent from our studies that the brain swells at the expense of brain blood volume and by measuring brain blood volume against brain mass, i.e., transit of 131 I antipyrine versus 51 Cr labeled red cells, one can detect brain edema in a situation where the brain scan would be normal. It is these approaches with cameras and computers using dual energies that may afford a more simplified estimation of altered regional brain function than is now available with the internal carotid injection technique. (U.S.)

  7. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  8. Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.

    Science.gov (United States)

    Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong

    2018-01-01

    With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.

  9. Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs

    International Nuclear Information System (INIS)

    Hale, S.L.; Alker, K.J.; Kloner, R.A.

    1988-01-01

    Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres

  10. Methods to Measure Map Readability

    OpenAIRE

    Harrie, Lars

    2009-01-01

    Creation of maps in real-time web services introduces challenges concerning map readability. Therefore we must introduce analytical measures controlling the readability. The aim of this study is to develop and evaluate analytical readability measures with the help of user tests.

  11. Prevalence of masked uncontrolled hypertension according to the number of office blood pressure measurements.

    Science.gov (United States)

    Vinyoles, E; Camafort, M; Domenech, M; Coca, A; Sobrino, J

    2015-11-01

    The reported prevalence of masked uncontrolled hypertension (MUCH) varies because many studies are not comparable as they use different measurement methodologies. To evaluate the influence of the number of office blood pressure readings on the prevalence of MUCH we conducted a cross-sectional, multicenter study in treated hypertensive patients. We carried out an observational, cross-sectional, multicenter study in 33 Spanish hospital-based hypertension units, involving 35 investigators and 12 Autonomous Communities. Six blood pressure readings and a 24-h ambulatory blood pressure monitoring were performed in treated hypertensive patients. The means of the first 3 readings (P123), the 2nd, 3rd and 4th readings (P234), the 3rd, 4th and 5th readings (P345) and the last 3 readings (P456) were compared with mean 24-h blood pressure. MUCH was defined as office blood pressure <140/90mmHg and 24-h blood pressure ≥130/80mmHg, considering the first 3 readings (MUCH123), the 2nd, 3rd and 4th readings (MUCH234), the 3rd, 4th and 5th readings (MUCH345) and the last 3 readings (MUCH456). We included 498 hypertensive patients. Mean (standard deviation) office blood pressure measurements were: (P123) 141(18)/82(11); (P234) 139(17)/81(11); (P345) 138(17)/81(11) and (P456) 137(16)/80(10) mmHg. Mean 24-h blood pressure was 127(13.8)/75(9.5) mmHg. The correlation coefficients between ambulatory and office systolic/diastolic blood pressure were (P123):0.48/0.50; (P234):0.50/0.52; (P345):0.50/0.54; and (P456):0.50/0.55 (p<0.001, all). The prevalences of MUCH123, MUCH234, MUCH345 and MUCH456 were 14.5%, 18.9%, 19.5% and 21.1%, respectively. The prevalence of MUCH diagnosis depends on the serial office blood pressure readings, being much higher for the last three blood pressure readings. Discarding the first and second office blood pressure measures seems to be the most accurate method for diagnosing MUCH. Copyright © 2015 Elsevier España, S.L.U. y Sociedad Española de Medicina

  12. Visual estimation versus gravimetric measurement of postpartum blood loss: a prospective cohort study.

    Science.gov (United States)

    Al Kadri, Hanan M F; Al Anazi, Bedayah K; Tamim, Hani M

    2011-06-01

    One of the major problems in international literature is how to measure postpartum blood loss with accuracy. We aimed in this research to assess the accuracy of visual estimation of postpartum blood loss (by each of two main health-care providers) compared with the gravimetric calculation method. We carried out a prospective cohort study at King Abdulaziz Medical City, Riyadh, Saudi Arabia between 1 November 2009 and 31 December 2009. All women who were admitted to labor and delivery suite and delivered vaginally were included in the study. Postpartum blood loss was visually estimated by the attending physician and obstetrics nurse and then objectively calculated by a gravimetric machine. Comparison between the three methods of blood loss calculation was carried out. A total of 150 patients were included in this study. There was a significant difference between the gravimetric calculated blood loss and both health-care providers' estimation with a tendency to underestimate the loss by about 30%. The background and seniority of the assessing health-care provider did not affect the accuracy of the estimation. The corrected incidence of postpartum hemorrhage in Saudi Arabia was found to be 1.47%. Health-care providers tend to underestimate the volume of postpartum blood loss by about 30%. Training and continuous auditing of the diagnosis of postpartum hemorrhage is needed to avoid missing cases and thus preventing associated morbidity and mortality.

  13. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  14. Student measurement of blood pressure using a simulator arm compared with a live subject's arm.

    Science.gov (United States)

    Lee, Jennifer J; Sobieraj, Diana M; Kuti, Effie L

    2010-06-15

    To compare accuracy of blood pressure measurements using a live subject and a simulator arm, and to determine students' preferences regarding measurement. This was a crossover study comparing blood pressure measurements from a live subject and a simulator arm. Students completed an anonymous survey instrument defining opinions on ease of measurement. Fifty-seven students completed blood pressure measurements on live subjects while 72 students completed blood pressure measurements using the simulator arm. There were no significant systematic differences between the 2 measurement techniques. Systolic blood pressure measurements from a live subject arm were less likely to be within 4 mm Hg compared with measurements of a simulator arm. Diastolic blood pressure measurements were not significantly different between the 2 techniques. Accuracy of student measurement of blood pressure using a simulator arm was similar to the accuracy with a live subject. There was no difference in students' preferences regarding measurement techniques.

  15. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network

    OpenAIRE

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network i...

  16. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  17. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids

    OpenAIRE

    Aarnes, Turi K.; Hubbell, John A.E.; Lerche, Phillip; Bednarski, Richard M.

    2012-01-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was −9.9 ± 21.9 mmHg with a range of −76 to 54 mmHg, and the 95% limits of agreement (LOA) were −33 to 53 mmHg. The difference between DABP measurements was −1...

  18. Measurement of blood flow from an assist ventricle by computation of pneumatic driving parameters.

    Science.gov (United States)

    Qian, K X

    1992-03-01

    The measurement of blood flow from an assist ventricle is important but sometimes difficult in artificial heart experiments. Along with the development of a pneumatic cylinder-piston driver coupled with a ventricular assist device, a simplified method for measuring pump flow was established. From driving parameters such as the piston (or cylinder) displacement and air pressure, the pump flow could be calculated by the use of the equation of state for an ideal gas. The results of this method are broadly in agreement with electromagnetic and Doppler measurements.

  19. Creatinine measurement on dry blood spot sample for chronic kidney disease screening.

    Science.gov (United States)

    Silva, Alan Castro Azevedo E; Gómez, Juan Fidel Bencomo; Lugon, Jocemir Ronaldo; Graciano, Miguel Luis

    2016-03-01

    Chronic kidney disease (CKD) screening is advisable due to its high morbidity and mortality and is usually performed by sampling blood and urine. Here we present an innovative and simpler method, by measuring creatinine on a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. The creatinine values obtained using both tests and the demographic data of each participant allowed us to determinate the eGFR. The adopted cutoff for CKD was an eGFR creatinine values differences (+ 0.68mg/dl to -0.55mg/dl) inside the ± 1.96 SD, without systematic differences. Measurement of creatinine on dry blood sample is an easily feasible non-invasive diagnostic test with good accuracy that may be useful to screen chronic kidney disease.

  20. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    International Nuclear Information System (INIS)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D'Ippolito, Giuseppe; Colleoni, Ramiro

    2008-01-01

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  1. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  2. Quantitative measurement of cerebral blood flow on patients with early syphilis

    International Nuclear Information System (INIS)

    Zhong Jijun; Wu Jinchang; Yang Yi; Tang Jun; Liu Zengli; Shi Xin

    2005-01-01

    To study quantitative change of cerebral blood flow (CBF) on patients with early syphilis, the authors have established a method on absolute measurement of rCBF by using SPECT with Ethyl Cysteinate Dimmer (ECD) as imaging agent, and the method was applied to measure rCBF on patients with early syphilis. The rCBF values measured by this method are highly consistent with the values measured by other classical methods such as SPECT ( 123 I-IMP) and PET( 15 O-H 2 O). The rCBF values for early syphilis patients and the normal control show some statistical differences. A routine quantitative absolute measurement of rCBF featured with simple procedures is therefore on the way of maturation. (authors)

  3. Optical clearing of tissues and blood using the immersion method

    International Nuclear Information System (INIS)

    Tuchin, Valery V

    2005-01-01

    This paper aims to review recent results on the optical clearing of the naturally turbid biological tissues and blood using the optical immersion technique, which is well known in physical science and is applied for the reduction of light scattering and undesirable reflections in the optical system. Basic principles of the technique, its advantages, limitations and future are discussed. The refractive index matching concept for enhancement of in-depth light penetration into tissues and blood is presented on the basis of in vitro and in vivo studies using optical spectroscopy, polarization and coherence-domain techniques. The index matching of scatterers and ground matter by means of administration of clearing agents is under discussion. The optical properties of tissues with basic multiple scattering, which are transformed to a low scattering mode, are analysed. It is shown that light reflection, transmission, scattering and polarization can be effectively controlled. The possibilities of using the optical immersion method for diagnostic purposes based on contrasting of abnormalities, on in-depth profiling of tissue and blood and on monitoring of endogenous and exogenous matter diffusion within tissue are demonstrated

  4. Simple method for culture of peripheral blood lymphocytes of Testudinidae.

    Science.gov (United States)

    Silva, T L; Silva, M I A; Venancio, L P R; Zago, C E S; Moscheta, V A G; Lima, A V B; Vizotto, L D; Santos, J R; Bonini-Domingos, C R; Azeredo-Oliveira, M T V

    2011-12-06

    We developed and optimized a simple, efficient and inexpensive method for in vitro culture of peripheral blood lymphocytes from the Brazilian tortoise Chelonoidis carbonaria (Testudinidae), testing various parameters, including culture medium, mitogen concentration, mitotic index, culture volume, incubation time, and mitotic arrest. Peripheral blood samples were obtained from the costal vein of four couples. The conditions that gave a good mitotic index were lymphocytes cultured at 37°C in minimum essential medium (7.5 mL), with phytohemagglutinin as a mitogen (0.375 mL), plus streptomycin/penicillin (0.1 mL), and an incubation period of 72 h. Mitotic arrest was induced by 2-h exposure to colchicine (0.1 mL), 70 h after establishing the culture. After mitotic arrest, the cells were hypotonized with 0.075 M KCl for 2 h and fixed with methanol/acetic acid (3:1). The non-banded mitotic chromosomes were visualized by Giemsa staining. The diploid chromosome number of C. carbonaria was found to be 52 in females and males, and sex chromosomes were not observed. We were able to culture peripheral blood lymphocytes of a Brazilian tortoise in vitro, for the preparation of mitotic chromosomes.

  5. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  6. Measurement of blood calprotectin (MRP-8/MRP-14) levels in patients with juvenile idiopathic arthritis.

    Science.gov (United States)

    Bojko, Jaryna

    2017-01-01

    The aim of the investigation was to compare blood calprotectin (MRP8/14, S100A 8/9) levels in patients with systemic-onset, polyarticular, RF-negative and oligoarticular subtypes of juvenile idiopathic arthritis (JIA), and to explore links between blood calprotectin levels and clinical and laboratory markers of JIA activity. Measurement of calprotectin in blood serum was performed in 160 patients with JIA followed up at Lviv Regional Council Public Institution "Western-Ukrainian Specialised Children's Medical Centre". Seventeen patients with systemic-onset JIA (sJIA) and 49 patients with other JIA subtypes (RF-negative polyarthritis and oligoarthritis) in the active phase of the disease were included in this study. Determination of calprotectin levels in blood serum was performed using EK-MRP8/14 Buhlmann Calprotectin reagents (Buhlmann, Switzerland) by the ELISA method. The results of the investigations showed that blood calprotectin levels were higher in patients with systemic-onset subtype of the disease (median 13,800 ng/ml), and differed significantly from levels in healthy children (median 1,800 ng/ml, p = 0.00002), levels in patients with articular subtypes of JIA (median 2,700 ng/ml, p = 0.000008), and patients with RF-negative polyarthritis (median 3,800 ng/ml, p = 0.003226) and oligoarthritis (median 2,500 ng/ml, p = 0.000009). The highest blood calprotectin levels were found in patients with newly diagnosed sJIA, the median being 32,500 ng/ml (range: 13,800-177,000 ng/ml). Direct correlations were found between blood calprotectin and JADAS 27 activity score ( p = 0.000009), ESR ( p = 0.000079) and CRP ( p = 0.000058). Blood calprotectin level is one of the measures that can be used to confirm the diagnosis of sJIA and to monitor the disease activity and therapy effectiveness.

  7. [Measurement of the blood flow in various areas of the rat brain by means of microspheres].

    Science.gov (United States)

    Deroo, J; Gerber, G B

    1976-01-01

    A method is described to measure regional blood flow in different structures of the rat brain. Microspheres (15 micron) are injected, the brain is sectioned, stained for myeline, radioautographs are prepared and the microspheres in the different structures are counted. The values obtained for different brain structures are counted. The values obtained for different brain regions (cortex, corpus callosum, thalamus hipocampus, hypothalamic region, colliculi, cerebellum, pons, medulla) compare well with those published by others on larger animals. In rats fed 1% of lead from birth, higher blood flow is found in the cortex and a lower one in the interior part of the brain compared to controls.

  8. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and a......, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)...

  9. A Study on Anthropometric Measurements, Blood Pressure, Blood Sugar and Food Intakes Among Different Social Status and Ethnicities

    Directory of Open Access Journals (Sweden)

    Jafarirad

    2016-09-01

    Full Text Available Background Metabolic syndrome is a disorder that increases the risk of cardiovascular disease and diabetes. Objectives The aim of the study was to evaluate some risk factors of the metabolic syndrome and food intakes among people who lived in Ahvaz City, Iran. Methods It was a filed study that was conducted on 211 subjects who participated in health exhibition. Socioeconomic status and ethnicity were asked by a general questionnaire. Weight, height, body mass index, waist circumference (WC and WC to hip circumference ratio (WHR were obtained. Blood sugar was measured by a glucometer. Systolic and diastolic blood pressures were obtained and dietary intakes were assessed by a brief instrument. Results There was a significant difference in weight, height, WC, WHR and systolic blood pressure among different jobs. Workers had more intakes of cake and sweets. Arab subjects had more intakes of bread and fishes and Persians more intakes of vegetables. Soda, chocolate and candy were more consumed by Kurd ethnicity. Conclusions Job may be accounted as an important effective socioeconomic factor related to metabolic syndrome risk factors; also different cultures due to different ethnicities may have an influence on lifestyle and dietary intakes.

  10. Low level TOC measurement method

    Science.gov (United States)

    Ekechukwu, Amy A.

    2001-01-01

    A method for the determination of total organic carbon in an aqueous sample by trapping the organic matter on a sorbent which is carbon free and analyzing the sorbent by combustion and determination of total CO.sub.2 by IR.

  11. Automated Methods of Corrosion Measurements

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    . Mechanical control, recording, and data processing must therefore be automated to a high level of precision and reliability. These general techniques and the apparatus involved have been described extensively. The automated methods of such high-resolution microscopy coordinated with computerized...

  12. Blood doping by cobalt. Should we measure cobalt in athletes?

    Directory of Open Access Journals (Sweden)

    Guidi Gian

    2006-07-01

    Full Text Available Abstract Background Blood doping is commonplace in competitive athletes who seek to enhance their aerobic performances through illicit techniques. Presentation of the hypothesis Cobalt, a naturally-occurring element with properties similar to those of iron and nickel, induces a marked and stable polycythemic response through a more efficient transcription of the erythropoietin gene. Testing the hypothesis Although little information is available so far on cobalt metabolism, reference value ranges or supplementation in athletes, there is emerging evidence that cobalt is used as a supplement and increased serum concentrations are occasionally observed in athletes. Therefore, given the athlete's connatural inclination to experiment with innovative, unfair and potentially unhealthy doping techniques, cobalt administration might soon become the most suited complement or surrogate for erythropoiesis-stimulating substances. Nevertheless, cobalt administration is not free from unsafe consequences, which involve toxic effects on heart, liver, kidney, thyroid and cancer promotion. Implications of the hypothesis Cobalt is easily purchasable, inexpensive and not currently comprehended within the World Anti-Doping Agency prohibited list. Moreover, available techniques for measuring whole blood, serum, plasma or urinary cobalt involve analytic approaches which are currently not practical for antidoping laboratories. Thus more research on cobalt metabolism in athletes is compelling, along with implementation of effective strategies to unmask this potentially deleterious doping practice

  13. Cerebral blood oxygenation measurements in neonates with optoacoustic technique

    Science.gov (United States)

    Herrmann, Stephen; Petrov, Irene Y.; Petrov, Yuriy; Richardson, C. Joan; Fonseca, Rafael A.; Prough, Donald S.; Esenaliev, Rinat O.

    2017-03-01

    Cerebral hypoxia is a major contributor to neonatal/infant mortality and morbidity including severe neurological complications such as mental retardation, cerebral palsy, motor impairment, and epilepsy. Currently, no technology is capable of accurate monitoring of neonatal cerebral oxygenation. We proposed to use optoacoustics for this application by probing the superior sagittal sinus (SSS), a large central cerebral vein. We developed and built a multi-wavelength, optical parametric oscillator (OPO) and laser diode optoacoustic systems for measurement of SSS blood oxygenation in the reflection mode through open anterior or posterior fontanelles and in the transmission mode through the skull in the occipital area. In this paper we present results of initial tests of the laser diode system for neonatal cerebral oxygenation measurements. First, the system was tested in phantoms simulating neonatal SSS. Then, using the data obtained in the phantoms, we optimized the system's hardware and software and tested it in neonates admitted in the Neonatal Intensive Care Unit. The laser diode system was capable of detecting SSS signals in the reflection mode through the open anterior and posterior fontanelles as well as in the transmission mode through the skull with high signal-to-noise ratio. Using the signals measured at different wavelengths and algorithms developed for oxygenation measurements, the laser diode system provided real-time, continuous oxygenation monitoring with high precision at all these locations.

  14. Current lung water measurement methods in man

    International Nuclear Information System (INIS)

    Basset, G.; Moreau, F.; Marsac, J.; Capitini, R.; Botter, F.

    1979-01-01

    Two kinds of tracer method are used to estimate the lung water pools differing by the tracer intake and the sector observed. Airborne intake gives an estimate of the tissues irrigated by the lung and bronchial circulation, whereas vascular intake only shows the sectors perfused by the lung flow. Either of these methods is suitable for a general or regional analysis. In general methods the tracer is followed at the lung exit on expired air for the first method, on peripheral arterial blood for the second. Regional methods imply partial or whole-lung external detection systems [fr

  15. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  16. The reflection seismology measurement method

    International Nuclear Information System (INIS)

    Sprecher, C.

    1987-01-01

    Even though data acquisition and data processing procedures have become more and more complex in recent decades, the end products of a reflection seismic survey have remained simple and illustrative. A seismic section resembles a geological cross-section and can be interpreted without in-depth knowledge provided that the basic principles behind the method are understood. This article attempts to convey some insight into the methodology without claiming to be scientifically exact or complete. (author)

  17. Precision and accuracy of blood glucose measurements using three different instruments.

    Science.gov (United States)

    Nowotny, B; Nowotny, P J; Strassburger, K; Roden, M

    2012-02-01

    Assessment of insulin sensitivity by dynamic metabolic tests such as the hyperinsulinemic euglycemic clamp critically relies on the reproducible and fast measurement of blood glucose concentrations. Although various instruments have been developed over the last decades, little is known as to the accuracy and comparability. We therefore compared the best new instrument with the former gold standard instruments to measure glucose concentrations in metabolic tests. Fasting blood samples of 15 diabetic and 10 healthy subjects were collected into sodium-fluoride tubes, spiked with glucose (0, 2.8, 6.9 and 11.1 mmol/l) and measured either as whole blood (range 3.3-26.3 mmol/l) or following centrifugation as plasma (range 3.9-32.0 mmol/l). Plasma samples were analyzed in the YSI-2300 STAT plus (YSI), EKF Biosen C-Line (EKF) and the reference method, Beckman Glucose analyzer-II (BMG), whole blood samples in EKF instruments with YSI as reference method. The average deviation of the EKF from the reference, BMG, was 3.0 ± 3.5% without any concentration-dependent variability. Glucose measurements by YSI were in good agreement with that by BMG (plasma) and EKF (plasma and whole blood) up to concentrations of 13.13 mmol/l (0.5 ± 3.7%), but deviation increased to -6.2 ± 3.8% at higher concentrations. Precision (n = 6) was ±2.2% (YSI), ±3.9% (EKF) and ±5.2% (BMG). The EKF instrument is comparable regarding accuracy and precision to the reference method BMG and can be used in metabolic tests, while the YSI showed a systematic shift at higher glucose concentrations. Based on these results we decided to replace BMG with EKF instrument in metabolic tests. © 2012 The Authors. Diabetic Medicine © 2012 Diabetes UK.

  18. Health economics and outcomes methods in risk-based decision-making for blood safety.

    Science.gov (United States)

    Custer, Brian; Janssen, Mart P

    2015-08-01

    Analytical methods appropriate for health economic assessments of transfusion safety interventions have not previously been described in ways that facilitate their use. Within the context of risk-based decision-making (RBDM), health economics can be important for optimizing decisions among competing interventions. The objective of this review is to address key considerations and limitations of current methods as they apply to blood safety. Because a voluntary blood supply is an example of a public good, analyses should be conducted from the societal perspective when possible. Two primary study designs are recommended for most blood safety intervention assessments: budget impact analysis (BIA), which measures the cost to implement an intervention both to the blood operator but also in a broader context, and cost-utility analysis (CUA), which measures the ratio between costs and health gain achieved, in terms of reduced morbidity and mortality, by use of an intervention. These analyses often have important limitations because data that reflect specific aspects, for example, blood recipient population characteristics or complication rates, are not available. Sensitivity analyses play an important role. The impact of various uncertain factors can be studied conjointly in probabilistic sensitivity analyses. The use of BIA and CUA together provides a comprehensive assessment of the costs and benefits from implementing (or not) specific interventions. RBDM is multifaceted and impacts a broad spectrum of stakeholders. Gathering and analyzing health economic evidence as part of the RBDM process enhances the quality, completeness, and transparency of decision-making. © 2015 AABB.

  19. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  20. Measuring methods of matrix diffusion

    International Nuclear Information System (INIS)

    Muurinen, A.; Valkiainen, M.

    1988-03-01

    In Finland the spent nuclear fuel is planned to be disposed of at large depths in crystalline bedrock. The radionuclides which are dissolved in the groundwater may be able to diffuse into the micropores of the porous rock matrix and thus be withdrawn from the flowing water in the fractures. This phenomenon is called matrix diffusion. A review over matrix diffusion is presented in the study. The main interest is directed to the diffusion of non-sorbing species. The review covers diffusion experiments and measurements of porosity, pore size, specific surface area and water permeability

  1. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    Science.gov (United States)

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  2. Cerebral blood flow (CBF) with 133Xe inhalation method

    International Nuclear Information System (INIS)

    Kusunoki, Tadaki; Masumura, Michio; Tamaki, Norihiko; Matsumoto, Satoshi; Yamashita, Hideyuki.

    1982-01-01

    The effects of CO 2 inhalation on the cerebral blood flow (CBF) were examined with 133 Xe inhalation method (Novo Inhalation Cerebrograph) on 9 normal peoples and 20 patients. Nine normal peoples were divided into 3 groups consisting of each 3 peoples, namely young age group, middle age group, and old age group. Each increased CBF (%) by CO 2 inhalation was 40 -- 44 in young age group, 36 -- 37 in middle age group, and 35 -- 36 in old age group in the blood flow of the first compartment (F 1 ), and 27 -- 28 in young age group, 30 -- 31 in middle age group and 23 -- 24 in old age group in the initial slope index (ISI). Each CO 2 reactivity factor (RF) was 5.5 -- 5.8 in young age group, 3.8 -- 4.0 in middle age group and 3.3 in old age group in F 1 , and 3.1 -- 3.2 in young age group, 2.0 -- 3.3 in middle age group, and 1.2 -- 1.3 in old age group in ISI. Twenty patients consisted of 15 patients of occlusive cerebrovascular disease, 2 patients of head injury, 2 patients of normal pressure hydrocephalus and one patient of subarachnoid hemorrhage. RF was abnormally lower than normal value in 5 patients in F 1 , but in 7 in ISI. Clinical benefits of CBF study during CO 2 inhalation with 133 Xe inhalation method were discussed. (author)

  3. Particle measurement systems and methods

    Science.gov (United States)

    Steele, Paul T [Livermore, CA

    2011-10-04

    A system according to one embodiment includes a light source for generating light fringes; a sampling mechanism for directing a particle through the light fringes; and at least one light detector for detecting light scattered by the particle as the particle passes through the light fringes. A method according to one embodiment includes generating light fringes using a light source; directing a particle through the light fringes; and detecting light scattered by the particle as the particle passes through the light fringes using at least one light detector.

  4. Method for the assessment of placental blood perfusion using /sup 99/Tc pertechnetate

    Energy Technology Data Exchange (ETDEWEB)

    Suonio, S; Olkkonen, H [Kuopio Central Hospital (Finland)

    1977-10-01

    A radioisotope method was developed for the measurement of placental blood flow using /sup 99/Tc pertechnetate as a tracer and a single detector as a measuring device. The results are given as placental perfusion rate (ml/min/ml) calculated from the tracer-appearance curve. The series consisted of 148 healthy pregnant women between the 28th and 42nd week and fifty pregnancies with a hypertensive disease. In healthy subjects the placental perfusion rate increased by about 32% in the period between 28th and 38th week, but there was a large variation. The perfusion rate showed a tendency to diminish at term. In a group of fifty hypertensive pregnancies a highly significant decrease in the perfusion rate was observed when compared with normal subjects. The conclusion drawn is that this method can be used for the quantitative measurement of placental blood supply.

  5. Methods for measurement of durability parameters

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1996-01-01

    Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included.......Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included....

  6. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  7. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  8. Difference in blood pressure measurements between arms: methodological and clinical implications.

    Science.gov (United States)

    Clark, Christopher E

    2015-01-01

    Differences in blood pressure measurements between arms are commonly encountered in clinical practice. If such differences are not excluded they can delay the diagnosis of hypertension and can lead to poorer control of blood pressure levels. Differences in blood pressure measurements between arms are associated cross sectionally with other signs of vascular disease such as peripheral arterial disease or cerebrovascular disease. Differences are also associated prospectively with increased cardiovascular mortality and morbidity and all cause mortality. Numbers of publications on inter-arm difference are rising year on year, indicating a growing interest in the phenomenon. The prevalence of an inter-arm difference varies widely between reports, and is correlated with the underlying cardiovascular risk of the population studied. Prevalence is also sensitive to the method of measurement used. This review discusses the prevalence of an inter-arm difference in different populations and addresses current best practice for the detection and the measurement of a difference. The evidence for clinical and for vascular associations of an inter-arm difference is presented in considering the emerging role of an inter-arm blood pressure difference as a novel risk factor for increased cardiovascular morbidity and mortality. Competing aetiological explanations for an inter-arm difference are explored, and gaps in our current understanding of this sign, along with areas in need of further research, are considered.

  9. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    Science.gov (United States)

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  10. Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in Korea.

    Science.gov (United States)

    Kim, Sehun; Park, Jin Joo; Lee, Seung-Ah; Cho, Youngjin; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Cho, Young-Seok; Youn, Tae-Jin; Cho, Goo-Yeong; Chae, In-Ho; Lee, Hae-Young; Shin, Jinho; Park, Sungha; Choi, Dong-Ju

    2018-01-01

    Currently, office blood pressure (OBP) is the most widely used method of measuring blood pressure (BP) in daily clinical practice. However, data on the diagnostic accuracy of OBP in reference to ambulatory blood pressure (ABP) are scarce in Korea. In retrospective and prospective cohorts, manual OBP and ABP measurements were compared among ambulatory hypertensive patients. Hypertension was defined as systolic OBP ≥ 140 mmHg and/or diastolic OBP ≥ 90 mmHg, and systolic ABP ≥ 130 mmHg and/or diastolic ABP ≥ 80 mmHg. In the retrospective cohort (n = 903), the mean OBP1 (before ABP measurement) was higher than ABP in both systolic (138 ± 17 mmHg vs. 123 ± 13 mmHg, p ABP ( r 2 = 0.038, p ABP, which is the reference method for measuring BP, was 43.9%. The prospective cohort (n = 57) showed similar results. In a subgroup analysis, male patients had higher false negative results (masked or under-treated hypertension) than did female patients (26.1% vs. 17.8%, p = 0.003), whereas female patients had a higher false positive rate (white-coat or over-treated hypertension) than did male patients (28.7% vs. 15.2%, p ABP. Men and women have different patterns of discordance. These findings indicate that management of hypertensive patients with manual OBP measurements may be suboptimal and encourages the use of ABP in ambulatory hypertensive patients.

  11. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    by ultrasound dilution was determined within three days of the procedure. The methods were compared using regression analysis and tested for systematic bias. Results: Failure to position the thermodilutional catheter correctly was observed in 8 out of 46 (17%) pre-intervention measurements. Post-intervention......Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  12. Fluorescence Exclusion: A Simple Method to Assess Projected Surface, Volume and Morphology of Red Blood Cells Stored in Blood Bank

    Directory of Open Access Journals (Sweden)

    Camille Roussel

    2018-05-01

    Full Text Available Red blood cells (RBC ability to circulate is closely related to their surface area-to-volume ratio. A decrease in this ratio induces a decrease in RBC deformability that can lead to their retention and elimination in the spleen. We recently showed that a subpopulation of “small RBC” with reduced projected surface area accumulated upon storage in blood bank concentrates, but data on the volume of these altered RBC are lacking. So far, single cell measurement of RBC volume has remained a challenging task achieved by a few sophisticated methods some being subject to potential artifacts. We aimed to develop a reproducible and ergonomic method to assess simultaneously RBC volume and morphology at the single cell level. We adapted the fluorescence exclusion measurement of volume in nucleated cells to the measurement of RBC volume. This method requires no pre-treatment of the cell and can be performed in physiological or experimental buffer. In addition to RBC volume assessment, brightfield images enabling a precise definition of the morphology and the measurement of projected surface area can be generated simultaneously. We first verified that fluorescence exclusion is precise, reproducible and can quantify volume modifications following morphological changes induced by heating or incubation in non-physiological medium. We then used the method to characterize RBC stored for 42 days in SAG-M in blood bank conditions. Simultaneous determination of the volume, projected surface area and morphology allowed to evaluate the surface area-to-volume ratio of individual RBC upon storage. We observed a similar surface area-to-volume ratio in discocytes (D and echinocytes I (EI, which decreased in EII (7% and EIII (24%, sphero-echinocytes (SE; 41% and spherocytes (S; 47%. If RBC dimensions determine indeed the ability of RBC to cross the spleen, these modifications are expected to induce the rapid splenic entrapment of the most morphologically altered RBC

  13. Measurement of MC5 antibody distribution in blood and bone marrow

    International Nuclear Information System (INIS)

    Johnson, T.K.; Gonzales, R.; Kasliwal, R.; Lear, J.; Feyerabend, A.; Ceriani, R.; Bunn, P.

    1990-01-01

    PURPOSE: Bone marrow is most often the dose-limiting organ in radioimmunotherapy. Controversy exists over optimal methods of estimating dose exposure to bone marrow. The purpose of this paper is to compare bone marrow activity from serial blood samples versus bone marrow biopsy specimens as measures of dose exposure to bone marrow. Peripheral blood samples and bone marrow biopsy specimens were obtained at 48 and 168 hours after infusion from 12 female patients infused with iodine-131-labeled MC5 antibody. The percentage of bone marrow in each biopsy specimen was assumed to be equivalent to the percentage of active bone marrow estimated to be in the pelvis. Activity present in the bone marrow as calculated with use of the estimated bone marrow mass for an adult female and then compared with the peripheral blood activity

  14. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  15. Monitoring total boron in blood for BNCT by a novel atomic emission method

    International Nuclear Information System (INIS)

    Laakso, J.; Kulvik, M.; Ruokonen, I.; Vaehaetalo, J.; Faerkkilae, M.; Kallio, M.; Zilliacus, R.

    2000-01-01

    In BNCT the duration and timing of the is adjusted by 10 B concentrations in whole blood. Time-frame for determinations is less than 20 minutes. Therefore fast and accurate boron determinations are a prerequisite for BNCT. We present a method based on ICP-AES instrument for whole blood and plasma boron determinations with protein precipitation with trichloroacetic acid as sample pre-treatment and beryllium as an internal standard. The method was compared to established but tedious ICP-mass spectrometric method with wet ashing as a sample pre-treatment. The ICP-AES method is in good agreement (correlation coefficient 0.99) the ICP-MS. Within-day and between-day imprecisions were less than 3,5% CV for whole blood samples. Samples taken during and after BPA-F infusion (290 mg/kg) revealed an uneven distribution between plasma and erythrocytes. The present method is feasible and one of the fastest currently available for BNCT. Our results indicate that BPA-F or its metabolites do not seem to be tightly bound to plasma proteins. It also seems that determination of boron in plasma sample may be preferable than measuring boron in whole blood. (author)

  16. Using qualitative research methods in biomedical innovation: the case of cultured red blood cells for transfusion.

    Science.gov (United States)

    Lyall, Catherine; King, Emma

    2016-05-11

    Qualitative research has a key role to play in biomedical innovation projects. This article focuses on the appropriate use of robust social science methodologies (primarily focus group studies) for identifying the public's willingness and preference for emerging medical technologies. Our study was part of the BloodPharma project (now known as the Novosang project) to deliver industrially generated red blood cells for transfusion. Previous work on blood substitutes shows that the public prefers donated human blood. However, no research has been conducted concerning attitudes to stem cell derived red blood cells. Qualitative research methods including interviews and focus groups provide the methodological context for this paper. Focus groups were used to elicit views from sub-sections of the UK population about the potential use of such cultured red blood cells. We reflect on the appropriateness of that methodology in the context of the BloodPharma project. Findings are in the form of lessons transferable to other interdisciplinary, science-led teams about what a social science dimension can bring; why qualitative research should be included; and how it can be used effectively. Qualitative data collection offers the strength of exploring ambivalence and investigating the reasons for views, but not necessarily their prevalence in wider society. The inherent value of a qualitative method, such as focus groups, therefore lies in its ability to uncover new information. This contrasts with a quantitative approach to simply 'measuring' public opinion on a topic about which participants may have little prior knowledge. We discuss a number of challenges including: appropriate roles for embedded social scientists and the intricacies of doing upstream engagement as well as some of the design issues and limitations associated with the focus group method.

  17. Precision of INR measured with a patient operated whole blood coagulometer

    DEFF Research Database (Denmark)

    Attermann, Jørn; Andersen, Niels Trolle; Korsgaard, Helle

    2003-01-01

    INTRODUCTION: The objective of the present study was to evaluate the precision of a portable whole blood coagulometer (CoaguChek S) in the hands of self-managing patients on oral anticoagulant therapy (OAT). MATERIALS AND METHODS: Fifteen patients on self-managed OAT performed measurements of INR...... and between patients was 15.0% and 14.7%, respectively. CONCLUSION: The precision of CoaguChek S is satisfactory....

  18. Association of adiposity measures with blood lipids and blood pressure in children aged 8-11 years.

    Science.gov (United States)

    Vizcaíno, Vicente Martínez; Aguilar, Fernando Salcedo; Martínez, Montserrat Solera; López, Mairena Sánchez; Gutiérrez, Ricardo Franquelo; Rodríguez-Artalejo, Fernando

    2007-09-01

    To examine the association of body mass index (BMI), triceps skinfold thickness (TST) and percentage body fat (%BF) from bioelectrical impedance analysis (BIA) with blood lipids, systolic blood pressure (SBP) and diastolic blood pressure (DBP) in children. Cross-sectional study was conducted on 1280 schoolchildren aged 8-11 years from the Cuenca province (Spain). Data collection was conducted under standardized conditions, taking several measurements of each variable to enhance accuracy. Analyses were performed using age-adjusted correlation coefficients, and multiple linear regression adjusted for age, BMI, TST and %BF. Correlations between %BF and apolipoprotein (apo) B, total cholesterol, low-density lipoprotein cholesterol (LDL-c), total cholesterol/HDL-c ratio and DBP were higher than those for BMI and TST. In contrast, the correlations between BMI, and apo A-I and SBP were higher than those for %BF and TST. The results were similar across the sexes. The correlations between each of the three measures of body fatness, and blood lipids and blood pressure were highest in children with greatest BMI and %BF. When analyses were adjusted for the three body fatness measures, %BF showed stronger associations than did BMI or TST with blood lipids and blood pressure, with the exception of apo A-I and SBP, which were more closely associated with BMI. %BF from BIA is more strongly associated than either BMI or TST with most of the blood lipid fractions in schoolchildren aged 8-11 years.

  19. An experimental method for detecting blood splatter from retractable phlebotomy and intravascular devices.

    Science.gov (United States)

    Haiduven, Donna; Applegarth, Shawn; Shroff, Miloni

    2009-03-01

    This study was designed to evaluate the safety of retractable intravascular devices in terms of their potential to produce blood splatter. A method for measuring this blood splatter designed by the research team was used to evaluate 3 specific intravascular devices. Scientific filters were positioned around the retraction mechanisms of the devices and weighed with an analytical scale, both before and after activation, in a simulated vein containing mock venous blood. The difference in filter mass was used as the primary unit of analysis to detect blood splatter. In addition, the filters were visually inspected for the presence or absence of blood. A paired t-test revealed significant differences in the prefilter and postfilter groups for 2 of the 3 devices tested (P blood was detected on 23% to 40% of the scientific filters for 2 of the devices. Our findings indicate a potential for bloodborne pathogen exposure with the use of intravascular devices with a retractable mechanism. This experiment may serve as a model in the design and implementation of future sharps device evaluation protocols to validate the threat of bloodborne pathogen exposure.

  20. Donating blood for research: a potential method for enhancing customer satisfaction of permanently deferred blood donors.

    Science.gov (United States)

    Waller, Daniel; Thijsen, Amanda; Garradd, Allira; Hayman, Jane; Smith, Geoff

    2017-01-01

    Each year, a large number of individuals in Australia are deferred from donating blood. A deferral may have a negative impact on donor satisfaction and subsequent word-of-mouth communication. The Australian Red Cross Blood Service (the Blood Service) is, therefore, investigating options for managing service interactions with deferred donors to maintain positive relationships. While public research institutes in Australia have established independent research donor registries, other countries provide programmes allowing deferred donors to donate blood for research via blood collection agencies. This study examined attitudes towards donating blood for research use in a sample of permanently deferred Australian donors. Donors permanently deferred because of a risk of variant Creutzfeldt-Jakob disease (n=449) completed a postal survey that examined attitudes towards research donation. The majority of participants were interested in donating blood for research (96%), and joining a registry of research donors (93%). Participants preferred to donate for transfusion or clinical research, and were willing to travel large distances. Results indicated that positive attitudes towards the Blood Service would be extended if the opportunity to donate blood was provided. These findings indicate a desire for continued engagement with the Blood Service despite deferral. Donating blood for research is a potential way of maintaining positive relationships with permanently deferred donors which also benefits the health research community. Through maintaining positive relationships with deferred donors, positive word-of-mouth activity can be stimulated. Further work is needed to determine the feasibility of implementing research donation through the Blood Service in Australia.

  1. [Measuring the blood pressure in both arms is of little use; longitudinal study into blood pressure differences between both arms and its reproducibility in patients with diabetes mellitus type 2].

    Science.gov (United States)

    Kleefstra, N; Houweling, S T; Meyboom-de Jong, B; Bilo, H J G

    2007-07-07

    To determine the prevalence of inter-arm blood pressure differences > 10 mmHg in patients with diabetes mellitus type 2 (DM2) and to determine whether these differences are consistent over time. Descriptive. In an evaluation study of 169 DM2 patients from 5 general practices in 2003 and 2004, different methods of oscillatory measurement were used to investigate inter-arm blood pressure differences > 10 mmHg systolic or diastolic. These methods were: one measurement in each arm non-simultaneously (method A), one measurement simultaneously (B) and the mean of two simultaneous measurements (C). With method A an inter-arm blood pressure difference was found in 33% of patients. This percentage diminished to 9 with method C. In 44% (n = 7) of the patients in whom method C detected a relevant blood pressure difference, this difference was not found with method A. In 79% of patients the inter-arm blood pressure difference was not reproduced after one year. In daily practice, one non-simultaneous blood pressure measurement in each arm (method A) was of little value for identification of patients with inter-arm blood pressure differences. The reproducibility was poor one year later. Bilateral blood pressure measurement is therefore of little value.

  2. Noninvasive measurement of blood glucose level using mid-infrared quantum cascade lasers

    Science.gov (United States)

    Yoshioka, Kiriko; Kino, Saiko; Matsuura, Yuji

    2017-04-01

    For non-invasive measurement of blood glucose level, attenuated total reflection (ATR) absorption spectroscopy system using a QCL as a light source was developed. The results of measurement of glucose solutions showed that the system had a sensitivity that was enough for blood glucose measurement. In-vivo measurement using the proposed system based on QCL showed that there was a correlation between absorptions measured with human lips and blood glucose level.

  3. 75 FR 22813 - Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred Because of...

    Science.gov (United States)

    2010-04-30

    ...] Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred Because of Reactive Test... availability of a document entitled ``Guidance for Industry: Requalification Method for Reentry of Blood Donors... document entitled ``Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred...

  4. Evaluation of a method for determination of the subcutaneous blood flow in the forefoot continuously over 24 h

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Bülow, J

    1984-01-01

    A method is presented which allows for continuous registration of forefoot blood flow over 24 h. Blood flow was estimated by the radioactive Xenon washout method and a portable CdTe detector system was used to measure the tracer disappearance rate. Since the semiconductor detector is placed very...... close to the tracer depot the washout rates registered are a mixture of rate constants due to tracer removal by blood flow and diffusion of the tracer depot away from the detector. Rate constants only due to diffusion were obtained over 24 h from amputated feet and similarly from normal feet...... with circulatory arrest in several 20 min periods during 24 h. The rate constants due to blood flow could thus be calculated by subtraction of the appropriate diffusion rate constants from the recorded rate constants. Blood flow in the forefoot during 24 h was measured in 10 experimental subjects with normal...

  5. Laser speckle imaging of rat retinal blood flow with hybrid temporal and spatial analysis method

    Science.gov (United States)

    Cheng, Haiying; Yan, Yumei; Duong, Timothy Q.

    2009-02-01

    Noninvasive monitoring of blood flow in retinal circulation will reveal the progression and treatment of ocular disorders, such as diabetic retinopathy, age-related macular degeneration and glaucoma. A non-invasive and direct BF measurement technique with high spatial-temporal resolution is needed for retinal imaging. Laser speckle imaging (LSI) is such a method. Currently, there are two analysis methods for LSI: spatial statistics LSI (SS-LSI) and temporal statistical LSI (TS-LSI). Comparing these two analysis methods, SS-LSI has higher signal to noise ratio (SNR) and TSLSI is less susceptible to artifacts from stationary speckle. We proposed a hybrid temporal and spatial analysis method (HTS-LSI) to measure the retinal blood flow. Gas challenge experiment was performed and images were analyzed by HTS-LSI. Results showed that HTS-LSI can not only remove the stationary speckle but also increase the SNR. Under 100% O2, retinal BF decreased by 20-30%. This was consistent with the results observed with laser Doppler technique. As retinal blood flow is a critical physiological parameter and its perturbation has been implicated in the early stages of many retinal diseases, HTS-LSI will be an efficient method in early detection of retina diseases.

  6. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  7. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  8. Emittance measurements by variable quadrupole method

    International Nuclear Information System (INIS)

    Toprek, D.

    2005-01-01

    The beam emittance is a measure of both the beam size and beam divergence, we cannot directly measure its value. If the beam size is measured at different locations or under different focusing conditions such that different parts of the phase space ellipse will be probed by the beam size monitor, the beam emittance can be determined. An emittance measurement can be performed by different methods. Here we will consider the varying quadrupole setting method.

  9. Optical tweezers for measuring the interaction of the two single red blood cells in flow condition

    Science.gov (United States)

    Lee, Kisung; Muravyov, Alexei; Semenov, Alexei; Wagner, Christian; Priezzhev, Alexander

    2017-03-01

    Aggregation of red blood cells (RBCs) is an intrinsic property of blood, which has direct effect on the blood viscosity and therefore affects overall the blood circulation throughout the body. It is attracting interest for the research in both fundamental science and clinical application. Despite of the intensive research, the aggregation mechanism is remaining not fully clear. Recent advances in methods allowed measuring the interaction between single RBCs in a well-defined configuration leading the better understanding of the mechanism of the process. However the most of the studies were made on the static cells. Thus, the measurements in flow mimicking conditions are missing. In this work, we aim to study the interaction of two RBCs in the flow conditions. We demonstrate the characterization of the cells interaction strength (or flow tolerance) by measuring the flow velocity to be applied to separate two aggregated cells trapped by double channel optical tweezers in a desired configuration. The age-separated cells were used for this study. The obtained values for the minimum flow velocities needed to separate the two cells were found to be 78.9 +/- 6.1 μm/s and 110 +/- 13 μm/s for old and young cells respectively. The data obtained is in agreement with the observations reported by other authors. The significance of our results is in ability for obtaining a comprehensible and absolute physical value characterizing the cells interaction in flow conditions (not like the Aggregation Index measured in whole blood suspensions by other techniques, which is some abstract parameter)

  10. Rapid Point of Care Analyzer for the Measurement of Cyanide in Blood

    Science.gov (United States)

    Ma, Jian; Ohira, Shin-Ichi; Mishra, Santosh K.; Puanngam, Mahitti; Dasgupta, Purnendu K.; Mahon, Sari B.; Brenner, Matthew; Blackledge, William; Boss, Gerry R.

    2011-01-01

    A simple, sensitive optical analyzer for the rapid determination of cyanide in blood in point of care applications is described. HCN is liberated by the addition of 20% H3PO4 and is absorbed by a paper filter impregnated with borate-buffered (pH 9.0) hydroxoaquocobinamide Hereinafter called cobinamide). Cobinamide on the filter changes color from orange (λmax = 510 nm) to violet (λmax = 583 nm) upon reaction with cyanide. This color change is monitored in the transmission mode by a light emitting diode (LED) with a 583 nm emission maximum and a photodiode detector. The observed rate of color change increases 10x when the cobinamide solution for filter impregnation is prepared in borate-buffer rather than in water. The use of a second LED emitting at 653 nm and alternate pulsing of the LEDs improve the limit of detection by 4x to ~ 0.5 μM for a 1 mL blood sample. Blood cyanide levels of imminent concern (≥ 10 μM) can be accurately measured in ~ 2 min. The response is proportional to the mass of cyanide in the sample – smaller sample volumes can be successfully used with proportionate change in the concentration LODs. Bubbling air through the blood-acid mixture was found effective for mixing of the acid with the sample and the liberation of HCN. A small amount of ethanol added to the top of the blood was found to be the most effective means to prevent frothing during aeration. The relative standard deviation (RSD) for repetitive determination of blood samples containing 9 μM CN was 1.09% (n=5). The technique was compared blind with a standard microdiffusion-spectrophotometric method used for the determination of cyanide in rabbit blood. The results showed good correlation (slope 1.05, r2 0.9257); independent calibration standards were used. PMID:21553921

  11. Optimally Repeatable Kinetic Model Variant for Myocardial Blood Flow Measurements with 82Rb PET

    Directory of Open Access Journals (Sweden)

    Adrian F. Ocneanu

    2017-01-01

    Full Text Available Purpose. Myocardial blood flow (MBF quantification with Rb82 positron emission tomography (PET is gaining clinical adoption, but improvements in precision are desired. This study aims to identify analysis variants producing the most repeatable MBF measures. Methods. 12 volunteers underwent same-day test-retest rest and dipyridamole stress imaging with dynamic Rb82 PET, from which MBF was quantified using 1-tissue-compartment kinetic model variants: (1 blood-pool versus uptake region sampled input function (Blood/Uptake-ROI, (2 dual spillover correction (SOC-On/Off, (3 right blood correction (RBC-On/Off, (4 arterial blood transit delay (Delay-On/Off, and (5 distribution volume (DV constraint (Global/Regional-DV. Repeatability of MBF, stress/rest myocardial flow reserve (MFR, and stress/rest MBF difference (ΔMBF was assessed using nonparametric reproducibility coefficients (RPCnp = 1.45 × interquartile range. Results. MBF using SOC-On, RVBC-Off, Blood-ROI, Global-DV, and Delay-Off was most repeatable for combined rest and stress: RPCnp = 0.21 mL/min/g (15.8%. Corresponding MFR and ΔMBF RPCnp were 0.42 (20.2% and 0.24 mL/min/g (23.5%. MBF repeatability improved with SOC-On at stress (p<0.001 and tended to improve with RBC-Off at both rest and stress (p<0.08. DV and ROI did not significantly influence repeatability. The Delay-On model was overdetermined and did not reliably converge. Conclusion. MBF and MFR test-retest repeatability were the best with dual spillover correction, left atrium blood input function, and global DV.

  12. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  13. Seven methods to measure ground moisture

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    The correct irrigation methods are of great importance to the deciduous fruit grower. The article discusses seven methods for the measuring of ground humidity. These methods are based on gravimetry, electric resistance, gamma attenuation, neutron humidity measurement, tensiometers and a study of the correlation between ground humidity and water evaporation. At this stage, the last technique is regarded as the most practicle method. Neutron moisture gages might be used if adhered to the regulations of NUCOR

  14. Practical utility of on-line clearance and blood temperature monitors as noninvasive techniques to measure hemodialysis blood access flow.

    Science.gov (United States)

    Fontseré, Néstor; Blasco, Miquel; Maduell, Francisco; Vera, Manel; Arias-Guillen, Marta; Herranz, Sandra; Blanco, Teresa; Barrufet, Marta; Burrel, Marta; Montaña, Javier; Real, Maria Isabel; Mestres, Gaspar; Riambau, Vicenç; Campistol, Josep M

    2011-01-01

    Access blood flow (Qa) measurements are recommended by the current guidelines as one of the most important components in vascular access maintenance programs. This study evaluates the efficiency of Qa measurement with on-line conductivity (OLC-Qa) and blood temperature monitoring (BTM-Qa) in comparison with the gold standard saline dilution method (SDM-Qa). 50 long-term hemodialysis patients (42 arteriovenous fistulas/8 arteriovenous grafts) were studied. Bland-Altman and Lin's coefficient (ρ(c)) were used to study accuracy and precision. Mean values were 1,021.7 ± 502.4 ml/min SDM-Qa, 832.8 ± 574.3 ml/min OLC-Qa (p = 0.007) and 1,094.9 ± 491.9 ml/min with BTM-Qa (p = NS). Biases and ρ(c) obtained were -188.8 ml/min (ρ(c) 0.58) OLC-Qa and 73.2 ml/min (ρ(c) 0.89) BTM-Qa. The limits of agreement (bias ± 1.96 SD) obtained were from -1,119 to 741.3 ml/min (OLC-Qa) and -350.6 to 497.2 ml/min (BTM-Qa). BTM-Qa and OLC-Qa are valid noninvasive and practical methods to estimate Qa, although BTM-Qa was more accurate and had better concordance than OLC-Qa compared with SDM-Qa. Copyright © 2010 S. Karger AG, Basel.

  15. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  16. Comparison of different screening methods for blood pressure disorders in children and adolescents

    Directory of Open Access Journals (Sweden)

    Felipe Alves Mourato

    2015-06-01

    Full Text Available OBJECTIVE: To compare different methods of screening for blood pressure disorders in children and adolescents. METHOD: A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. RESULTS: The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. CONCLUSION: Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables.

  17. Alternative methods for measuring obesity in African American women.

    Science.gov (United States)

    Clark, Ashley E; Taylor, Jacquelyn Y; Wu, Chun Yi; Smith, Jennifer A

    2013-03-01

    The use of body mass index (BMI) may not be the most appropriate measurement tool in determining obesity in diverse populations. We studied a convenience sample of 108 African American (AA) women to determine the best method for measuring obesity in this at-risk population. The purpose of this study was to determine if percent body fat (PBF) and percent body water (PBW) could be used as alternatives to BMI in predicting obesity and risk for hypertension (HTN) among AA women. After accounting for age, BMI, and the use of anti-hypertensive medication, PBF (p = 0.0125) and PBW (p = 0.0297) were significantly associated with systolic blood pressure, while BMI was not. Likewise, PBF (p = 0.0316) was significantly associated with diastolic blood pressure, while PBW and BMI were not. Thus, health care practitioners should consider alternative anthropometric measurements such as PBF when assessing obesity in AA women.

  18. Microcantilever based disposable viscosity sensor for serum and blood plasma measurements.

    Science.gov (United States)

    Cakmak, Onur; Elbuken, Caglar; Ermek, Erhan; Mostafazadeh, Aref; Baris, Ibrahim; Erdem Alaca, B; Kavakli, Ibrahim Halil; Urey, Hakan

    2013-10-01

    This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23°C and 37°C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 μl and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges. Copyright © 2013. Published by Elsevier Inc.

  19. assessment of measures of adiposity that correlate with blood

    African Journals Online (AJOL)

    health risk.8 Furthermore, its correlation with adiposity .... Data Management: Data were analyzed using the ... had good blood pressure control with no gender .... Journal of internal medicine. ... consensus statement from shaping America's.

  20. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  1. Radioimmunoassay of alpha-foetoprotein in the eluate of dried blood. A method for antenatal screening of neural tube defects

    International Nuclear Information System (INIS)

    Travert, G.; Herlicoviez, M.; Laroche, D.

    1979-01-01

    A radioimmunoassay for alpha-foetoprotein (AFP) in dried blood spots is reported. The main technical characteristics (reproducibility, sensitivity, recovery of exogenous AFP added and AFP stability in dried blood) are evaluated. They indicate that this method is feasible and well adapted to AFP measurement during pregnancy. AFP determination in maternal serum allows early detection of at least 80% of neural tube defects. The use of dried blood spots as samples for AFP assay makes our method a possible mass screening test for these malformations, which occur with an incidence of 12 for 10,000 [fr

  2. Blood flow rate measurements with indicator techniques revisited

    DEFF Research Database (Denmark)

    Sejrsen, Per; Bülow, Jens

    2009-01-01

    In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions......, necessary precautions for the application of these experimental techniques are emphasized. Special attention has been carried out to elucidate the consequence of a choice of indicators having a large distribution volume in the tissues....

  3. Simple method of measuring pulmonary extravascular water using heavy water

    Energy Technology Data Exchange (ETDEWEB)

    Basset, G; Moreau, F; Scaringella, M; Tistchenko, S; Botter, F; Marsac, J

    1975-11-20

    The field of application of the multiple indicators dilution method in human pathology, already used to study pulmonary edema, can be extended to cover the identification and testing of all conditions leading to increase lung water. To be really practical it must be simple, fast, sensitive, inexpensive and subject to repetition; the use of non-radioactive tracers is implied. Indocyanine Green and heavy water were chosen respectively as vascular and diffusible indicators. Original methods have been developed for the treatment and isotopic analysis of blood: mass spectrometric analysis of aqueous blood extracts after deproteinisation by zinc sulphate then rapid distillation of the supernatant under helium; infrared analysis either of acetone extracts from small blood samples (100..mu..litre) or of blood itself in a continuous measurement. The infrared technique adopted has been used on rats and on men in normal and pathological situations. The results show that the method proposed for the determination of pulmonary extravascular water meets the requirements of clinicians while respecting the patients' safety, and could be generalized to other organs.

  4. Handbook of nuclear safeguards measurement methods

    International Nuclear Information System (INIS)

    Rogers, D.R.

    1983-09-01

    This handbook is intended to be a guide to the selection of methods for meeting specific measurement requirements. The information was compiled from a survey of production facilities, the literature, and current exchange programs. The survey included bulk measurements, chemical assay, sampling techniques, isotopic measurements, passive NDA, and active NDA

  5. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  6. Agreement of serum potassium measured by blood gas and biochemistry analyzer in patients with moderate to severe hyperkalemia.

    Science.gov (United States)

    Acikgoz, Seyyid Bilal; Genc, Ahmet Bilal; Sipahi, Savas; Yildirim, Mehmet; Cinemre, Behice; Tamer, Ali; Solak, Yalcin

    2016-05-01

    Several studies investigated the agreement between central laboratory biochemistry analyzers and blood gas analyzers for potassium measurements. However, data are scarce when the potassium level is moderate to severely high. We aimed to evaluate the agreement between central laboratory biochemistry analyzers and blood gas analyzer in terms of serum potassium level measurement because differences in potassium at this level translate into very different clinical actions. This was a retrospective medical record review study in which patients who presented to the emergency department and had serum potassium levels ≥6mmol/L were included. Patients who did not have simultaneous potassium measurement by blood gas analyzer were excluded. We included all patients meeting potassium criteria irrespective of their underlying disease or comorbidities. We evaluated agreement between the measurement methods with Pearson correlation, Bland-Altman plot, and Sign test. A total of 118 blood sample pairs were included. The mean serum potassium level measured by biochemistry analyzer was 6.78±0.79mmol/L, whereas it was 6.16±0.86mmol/L by blood gas analyzer (Pbiochemistry analyzer. The mean difference between the methods was 0.62±0.43mmol/L. In patients with moderate to severe hyperkalemia, blood gas analyzer and biochemistry analyzer gives significantly different serum potassium results which may be clinically important. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?

    NARCIS (Netherlands)

    Langewouters, G. J.; Settels, J. J.; Roelandt, R.; Wesseling, K. H.

    1998-01-01

    In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkoff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the

  8. Development of radiochemical method of analysis of binding of tritium labeled drotaverine hydrochloride with human blood serum albumin

    International Nuclear Information System (INIS)

    Kim, A.A.; Djuraeva, G.T.; Shukurov, B.V.; Mavlyanov, I.R.

    2004-01-01

    Full text: The albumin, being a basic functional linkage of numerous endogenous and exogenous substances is the most important protein of blood plasma. At the diseases connected to liver disfunction, collected in blood metabolite reduce connecting ability of albumino. The aim of the present research was a development of radiochemical method of determination of ability of albumin to bind the tritium labeled preparation drotaverine hydrochloride (no - spa). We had developed a micromethod of definition of connecting ability of albumin, allowing to analyse 20 mkl of blood serum. The method consists in incubation of tritium labeled drotaverine hydrochloride with blood serum in vitro, the following fractionation of serum proteins by gel - filtration on a microcolumn with Sephadex G-25, and direct measurement of the radioactivity connected to fraction of proteins of blood serum. The method has been tested on a series of blood serum of control group of healthy people and on a series of blood serum of patients with hepatitis B. We received quantitative characteristics of binding of drotaverine hydrochloride with albumin of patients with hepatitis B. It was preliminary established that binding ability of serum albumin of children with various forms of acute virus hepatitis tends to decrease in comparison with group of the control. Advantage of the developed radiochemical method is high precision and the high sensitivity of detection of infringement of binding ability of albumin. Application of tritium labeled drotaverine hydrochloride allows to measure directly levels of binding of a preparation with albumin

  9. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  10. Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; van den Berg, Albert

    2004-01-01

    The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with

  11. Measuring method for optical fibre sensors

    NARCIS (Netherlands)

    Lammerink, Theodorus S.J.; Fluitman, J.H.J.

    1984-01-01

    A new measuring method for the signal amplitude in intensity modulating fibre optic sensors is described. A reference signal is generated in the time domain. The method is insensitive for the sensitivity fluctuations of the light transmitter and the light receiver. The method is experimentally

  12. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  13. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  14. Comparison of different screening methods for blood pressure disorders in children and adolescents.

    Science.gov (United States)

    Mourato, Felipe Alves; Lima Filho, José Luiz; Mattos, Sandra da Silva

    2015-01-01

    To compare different methods of screening for blood pressure disorders in children and adolescents. A database with 17,083 medical records of patients from a pediatric cardiology clinic was used. After analyzing the inclusion and exclusion criteria, 5,650 were selected. These were divided into two age groups: between 5 and 13 years and between 13 and 18 years. The blood pressure measurement was classified as normal, pre-hypertensive, or hypertensive, consistent with recent guidelines and the selected screening methods. Sensitivity, specificity, and accuracy were then calculated according to gender and age range. The formulas proposed by Somu and Ardissino's table showed low sensitivity in identifying pre-hypertension in all age groups, whereas the table proposed by Kaelber showed the best results. The ratio between blood pressure and height showed low specificity in the younger age group, but showed good performance in adolescents. Screening tools used for the assessment of blood pressure disorders in children and adolescents may be useful to decrease the current rate of underdiagnosis of this condition. The table proposed by Kaelber showed the best results; however, the ratio between BP and height demonstrated specific advantages, as it does not require tables. Copyright © 2014 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  15. Normal and system lupus erythematosus red blood cell interactions studied by double trap optical tweezers: direct measurements of aggregation forces

    Science.gov (United States)

    Khokhlova, Maria D.; Lyubin, Eugeny V.; Zhdanov, Alexander G.; Rykova, Sophia Yu.; Sokolova, Irina A.; Fedyanin, Andrey A.

    2012-02-01

    Direct measurements of aggregation forces in piconewton range between two red blood cells in pair rouleau are performed under physiological conditions using double trap optical tweezers. Aggregation and disaggregation properties of healthy and pathologic (system lupus erythematosis) blood samples are analyzed. Strong difference in aggregation speed and behavior is revealed using the offered method which is proposed to be a promising tool for SLE monitoring at single cell level.

  16. Cerebral blood flow measured by positron emission tomography during normothermic cardiopulmonary bypass: An experimental porcine study

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Kjaergaard, Benedict; Alstrup, Aage Kristian Olsen

    2018-01-01

    emission tomography (PET) using 15O-labelled water with no pharmacological interventions to maintain the MAP. Methods: Eight pigs (69-71 kg) were connected to normothermic CPB. After 60 minutes (min) with a CPB pump flow of 60 mL/kg/min, the pigs were changed to either 35 mL/kg/min or 47.5 mL/kg/min for 60......Background: Mean arterial blood pressure (MAP) and/or pump flow during normothermic cardiopulmonary bypass (CPB) are the most important factors of cerebral perfusion. The aim of this study was to explore the influence of CPB blood flow on cerebral blood flow (CBF) measured by dynamic positron...... min and, thereafter, all the pigs returned to 60 mL/kg/min for another 60 min. The MAP was measured continuously and the CBF was measured by positron emission tomography (PET) during spontaneous circulation and at each CPB pump flow after 30 min of steady state. Results: Two pigs were excluded due...

  17. Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation.

    Science.gov (United States)

    Kollias, Anastasios; Stergiou, George S

    2014-01-01

    1. Hypertension and atrial fibrillation (AF) often coexist and are strong risk factors for stroke. Current guidelines for blood pressure (BP) measurement in AF recommend repeated measurements using the auscultatory method, whereas the accuracy of the automated devices is regarded as questionable. This review presents the current evidence on the feasibility and accuracy of automated BP measurement in the presence of AF and the potential for automated detection of undiagnosed AF during such measurements. 2. Studies evaluating the use of automated BP monitors in AF are limited and have significant heterogeneity in methodology and protocols. Overall, the oscillometric method is feasible for static (office or home) and ambulatory use and appears to be more accurate for systolic than diastolic BP measurement. 3. Given that systolic hypertension is particularly common and important in the elderly, the automated BP measurement method may be acceptable for self-home and ambulatory monitoring, but not for professional office or clinic measurement. 4. An embedded algorithm for the detection of asymptomatic AF during routine automated BP measurement with high diagnostic accuracy has been developed and appears to be a useful screening tool for elderly hypertensives. © 2013 Wiley Publishing Asia Pty Ltd.

  18. Photoacoustic discrimination of viable and thermally coagulated blood using a two-wavelength method for burn injury monitoring

    International Nuclear Information System (INIS)

    Talbert, Robert J; Holan, Scott H; Viator, John A

    2007-01-01

    Discriminating viable from thermally coagulated blood in a burn wound can be used to profile burn depth, thus aiding the removal of necrotic tissue. In this study, we used a two-wavelength photoacoustic imaging method to discriminate coagulated and non-coagulated blood in a dermal burn phantom. Differences in the optical absorption spectra of coagulated and non-coagulated blood produce different values of the ratio of peak photoacoustic amplitude at 543 and 633 nm. The absorption values obtained from spectroscopic measurements indicate that the ratio of photoacoustic pressure for 543 and 633 nm for non-coagulated blood was 15.7:1 and 1.6:1 for coagulated blood. Using planar blood layers, we found the photoacoustic ratios to be 13.5:1 and 1.6:1, respectively. Using the differences in the ratios of coagulated and non-coagulated blood, we propose a scheme using statistical classification analysis to identify the different blood samples. Based upon these distinctly different ratios, we identified the planar blood samples with an error rate of 0%. Using a burn phantom with cylindrical vessels containing coagulated and non-coagulated blood, we achieved an error rate of 11.4%. These results have shown that photoacoustic imaging could prove to be a valuable tool in the diagnosis of burns

  19. Fibrinogen measurements in plasma and whole blood: a performance evaluation study of the dry-hematology system.

    Science.gov (United States)

    Ogawa, Satoru; Tanaka, Kenichi A; Nakajima, Yasufumi; Nakayama, Yoshinobu; Takeshita, Jun; Arai, Masatoshi; Mizobe, Toshiki

    2015-01-01

    An accurate and rapid determination of fibrinogen level is important during hemorrhage to establish a timely hemostatic intervention. The accuracy of fibrinogen measurements may be affected by the specific methodology for its determination, fluid therapies, and anticoagulant agents. The dry-hematology method (DRIHEMATO®) is a novel approach to determine fibrinogen levels in plasma and whole blood based on thrombin-activated coagulation time. We hypothesized that plasma or whole blood fibrinogen level using the dry-hematology method would be similar to those measured with conventional plasma fibrinogen assays. Acquired hypofibrinogenemia was modeled by serial dilutions of blood samples obtained from 12 healthy volunteers. Citrated whole blood samples were diluted with either normal saline, 5% human albumin, or 6% hydroxyethyl starch to achieve 25%, 50%, and 75% volume replacement. The dry-hematology method, the Clauss method, the prothrombin time (PT)-derived method, determination of antigen levels, and thromboelastometric fibrin formation were compared in plasma or whole blood samples. The effect of heparin on each assay was examined (0 to 6 IU/mL). Comparisons of dry-hematology and other methods were also conducted using ex vivo samples obtained from cardiac surgical patients (n = 60). In plasma samples, there were no significant differences between dry-hematology and the Clauss method, while dry-hematology showed lower fibrinogen levels compared with PT-derived and antigen level methods. The dry-hematology method yielded acceptable concordance correlation coefficients (Pc) with the Clauss method, the PT-derived method, and fibrinogen antigen levels (Pc = 0.91-0.99). The type of diluents and heparin affected the results of the PT-derived method and thromboelastometric assay, but not the dry-hematology method. In cardiac surgical patients, the overall correlation in fibrinogen levels between dry-hematology and the other methods was comparable to the results from

  20. Methods of measuring residual stresses in components

    International Nuclear Information System (INIS)

    Rossini, N.S.; Dassisti, M.; Benyounis, K.Y.; Olabi, A.G.

    2012-01-01

    Highlights: ► Defining the different methods of measuring residual stresses in manufactured components. ► Comprehensive study on the hole drilling, neutron diffraction and other techniques. ► Evaluating advantage and disadvantage of each method. ► Advising the reader with the appropriate method to use. -- Abstract: Residual stresses occur in many manufactured structures and components. Large number of investigations have been carried out to study this phenomenon and its effect on the mechanical characteristics of these components. Over the years, different methods have been developed to measure residual stress for different types of components in order to obtain reliable assessment. The various specific methods have evolved over several decades and their practical applications have greatly benefited from the development of complementary technologies, notably in material cutting, full-field deformation measurement techniques, numerical methods and computing power. These complementary technologies have stimulated advances not only in measurement accuracy and reliability, but also in range of application; much greater detail in residual stresses measurement is now available. This paper aims to classify the different residual stresses measurement methods and to provide an overview of some of the recent advances in this area to help researchers on selecting their techniques among destructive, semi destructive and non-destructive techniques depends on their application and the availabilities of those techniques. For each method scope, physical limitation, advantages and disadvantages are summarized. In the end this paper indicates some promising directions for future developments.

  1. Quantitative measurement of total cerebral blood flow using 2D phase-contrast MRI and doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Keum Soo; Choi, Sun Seob; Lee, Young Il [Dong-A Univ., College of Medicine, Busan (Korea, Republic of)

    2001-12-01

    To compare of quantitative measurement of the total cerebral blood flow using two-dimensional phase-contrast MR imaging and Doppler ultrasound. In 16 volunteers (mean age, 26 years; mean body weight, 66 kg) without abnormal medical histories, two-dimensional phase-contrast MR imaging was performed at the level of the C2-3 inter vertebral disc for flow measurement of the internal carotid arteries and the vertebral arteries. Volume flow measurements using Doppler ultrasound were also performed at the internal carotid arteries 2cm above the carotid bifurcation, and at the vertebral arteries at the level of the upper pole of the thyroid gland. Flows in the four vessels measured by the two methods were compared using Wilcoxon's correlation analysis and the median score. Total cerebral blood flows were calculated by summing these four vessel flows, and mean values for the 16 volunteers were calculated. Cerebral blood flows measured by 2-D phase-contrast MR imaging and Doppler ultrasounds were 233 and 239 ml/min in the right internal carotid artery, 250 and 248 ml/min in the left internal carotid artery, 62 and 56 ml/min in the right vertebral artery, and 83 and 68 ml/min in the left vertebral artery. Correlation coefficients of the blood flows determined by the two methods were 0.48, 0.54, 0.49, and 0.62 in each vessel, while total cerebral blood flows were 628{+-}68 (range, 517 to 779) ml/min and 612{+-}79 (range, 482 to 804)ml/min, respectively. Total cerebral blood flow was easily measured using 2-D phase-contrast MR imaging and Doppler ultrasound, and the two noninvasive methods can therefore be used clinically for the measurement of total cerebral blood flow.

  2. Measuring methods for the TFR plasma diagnostics

    International Nuclear Information System (INIS)

    Etievant, C.

    1975-02-01

    The measuring methods in operation or still under development for the diagnostics of the TFR plasma parameters (ion and electron temperatures, electron density, current density are reviewed, the diagnostics of the electrical behavior of the discharge, the neutral gas densities, the impurities and the parameters of the plasma turbulence being also investigated. Actual works are principally devoted to: improving ion temperature measurements by the possible use of the Doppler effect or infra-red incoherent scattering; improving n(e) and T(e) measurement by Thomson scattering; measuring the poloidal field and current density; measuring impurities by X and UV spectroscopy and measuring instabilities and turbulence [fr

  3. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  4. Ocular Blood Flow Measurements in Healthy White Subjects Using Laser Speckle Flowgraphy.

    Directory of Open Access Journals (Sweden)

    Nikolaus Luft

    Full Text Available To assess the feasibility and reliability of Laser Speckle Flowgraphy (LSFG to measure ocular perfusion in a sample of healthy white subjects and to elucidate the age-dependence of the parameters obtained.This cross-sectional study included 80 eyes of 80 healthy, non-smoking white subjects of Western European descent between 19 and 79 years of age. A commercial LSFG instrument was applied to measure ocular blood flow at the optic nerve head (ONH three successive times before and after pharmacological pupil dilation. The mean blur rate (MBR, a measure of relative blood flow velocity, was obtained for different regions of the ONH. Eight parameters of ocular perfusion derived from the pulse-waveform analysis of MBR including blowout time (BOT and falling rate (FR were also recorded.Artifact-free LSFG images meeting the quality criteria for automated image analysis were obtainable in 93.8% without pupil dilation and in 98.8% with pharmacological pupil dilation. Measurements of MBR showed excellent repeatability with intraclass correlation coefficients ≥ 0.937 and were barely affected by pupil dilation. The majority of pulse-waveform derived variables exhibited equally high repeatability. MBR-related blood flow indices exhibited significant age dependence (p<0.001. FR (r = 0.747, p<0.001 and BOT (r = -0.714, p<0.001 most strongly correlated with age.LSFG represents a reliable method for the quantitative assessment of ocular blood flow in white subjects. Our data affirms that the LSFG-derived variables FR and BOT may be useful biomarkers for age-related changes in ocular perfusion.

  5. Physically consistent data assimilation method based on feedback control for patient-specific blood flow analysis.

    Science.gov (United States)

    Ii, Satoshi; Adib, Mohd Azrul Hisham Mohd; Watanabe, Yoshiyuki; Wada, Shigeo

    2018-01-01

    This paper presents a novel data assimilation method for patient-specific blood flow analysis based on feedback control theory called the physically consistent feedback control-based data assimilation (PFC-DA) method. In the PFC-DA method, the signal, which is the residual error term of the velocity when comparing the numerical and reference measurement data, is cast as a source term in a Poisson equation for the scalar potential field that induces flow in a closed system. The pressure values at the inlet and outlet boundaries are recursively calculated by this scalar potential field. Hence, the flow field is physically consistent because it is driven by the calculated inlet and outlet pressures, without any artificial body forces. As compared with existing variational approaches, although this PFC-DA method does not guarantee the optimal solution, only one additional Poisson equation for the scalar potential field is required, providing a remarkable improvement for such a small additional computational cost at every iteration. Through numerical examples for 2D and 3D exact flow fields, with both noise-free and noisy reference data as well as a blood flow analysis on a cerebral aneurysm using actual patient data, the robustness and accuracy of this approach is shown. Moreover, the feasibility of a patient-specific practical blood flow analysis is demonstrated. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Photogrammetric methods of measurement in industrial applications

    International Nuclear Information System (INIS)

    Godding, R.; Groene, A.; Heinrich, G.; Schneider, C.T.

    1993-01-01

    Methods for 3D measurement are required for very varied applications in the industrial field. This includes tasks of quality assurance and plant monitoring, among others. It should be possible to apply the process flexibly it should require as short interruptions of production as possible and should meet the required accuracies. These requirements can be met by photogrammetric methods of measurement. The article introduces these methods and shows their capabilities from various selected examples (eg: the replacement of large components in a pressurized water reactor, and aircraft measurements (orig./DG) [de

  7. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  8. Aortic blood pressure measured via EIT: investigation of different measurement settings.

    Science.gov (United States)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Adler, Andy; Grychtol, Bartłomiej; Solà, Josep; Thiran, Jean-Philippe

    2015-06-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

  9. Aortic blood pressure measured via EIT: investigation of different measurement settings

    International Nuclear Information System (INIS)

    Braun, Fabian; Proença, Martin; Rapin, Michael; Lemay, Mathieu; Solà, Josep; Adler, Andy; Grychtol, Bartłomiej; Thiran, Jean-Philippe

    2015-01-01

    Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss–Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss–Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg. (paper)

  10. [Clinical signification of a modified dilution method (MDM) for blood loss assessment in the cases of nonvariceal upper gastrointestinal bleeding].

    Science.gov (United States)

    Geogiev, G; Shishenkov, M; Ninov, B; Dosheva, I

    2006-01-01

    The aim of this study was to compare the modified dilution method (MDM) for in vivo bloodless assessment with the accepted in the clinical practice methods. We measured 148 blood samples from 134 patients with nonvariceal upper gastrointestinal bleeding (NUGB) and 21 blood samples from healthy persons as a negative control. In the randomized group of 53 patients with NUGB we compared accuracy of the blood loss determination by means of erythrocyte mass loss (estimated with MDM), Allgower-Burri index and American College of Surgeon Index (ACSI). The obtained results give us a reason to recommend a combination between American College of Surgeon classification for blood loss in patients with NUGB and a parallel measurement of the MDM values.

  11. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  12. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

    Science.gov (United States)

    van Gastel, Mark; Stuijk, Sander; de Haan, Gerard

    2016-12-07

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO 2 ) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO 2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO 2 levels in the range 80-100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO 2 -error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO 2 remotely during significant subject motion.

  13. Validation of the Use of Dried Blood Spot (DBS) Method to Assess Vitamin A Status

    Science.gov (United States)

    Fallah, Elham; Peighambardoust, Seyed Hadi

    2012-01-01

    Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne¬cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS) method in screening the deficient populations. The validity of this method for retinol measurement was investigated. Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci¬sion was calculated and compared with those of plasma using F-test. The agreement was eva¬luated using Bland-Altman plot. Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma). A good correlation coefficient (r2=0.78) was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma. PMID:24688932

  14. Measurement methods for several properties of scintillator

    International Nuclear Information System (INIS)

    Luo Fengqun; Ji Changsong

    1998-01-01

    The current paper describes the experimental measurement methods for the relative light output, the relative energy conversion efficiency, the intrinsic amplitude resolution and the detection efficiency of the scintillators and their temperature effects

  15. EVALUATION OF THE BLOOD PRESSURE MEASURING KNOWLEDGE OF THE NURSES WHO ARE WORKING IN A MEDICAL FACULTY HOSPITAL

    Directory of Open Access Journals (Sweden)

    Tahir Kemal SAHIN

    2006-02-01

    Full Text Available Objective: The aim of this study is to determine the right knowledge of blood pressure measurement of the nurses who working in clinics. Materials and Method: 103 nurses who are working in Meram Medical Faculty Hospital were included to this descriptive study. Sampling method was stratified proportional random sampling method, with strata for the number of nurses at clinics. A questionnaire, which was formed of some questions about standard measuring methods of blood pressure, was applied to the nurses. Results: It was determined that 55.3% to 98.1% of the nurses answered the most of the questions correctly. But, they gave different answers to the questions about choosing the arm for measurement, inflation level of the cuff, deflation speed and how many measurements should be done for true result. It was found that the female nurses had much more knowledge about the tension of wrapping the cuff around the arm and the correct positioning of the stethescope than the male ones. Oppositely, the male nurses had higher correct answer rate about deflation of the cuff than the female nurses. Conclusion: It was concluded that the knowledge of blood pressure measurement of the nurses was partly insufficient. Periodical educational studies should be done for the nurses to complete the blood pressure measurement knowledge of them. [TAF Prev Med Bull 2006; 5(1.000: 8-18

  16. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...

  17. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  18. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  19. Absolute measurement method of environment radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1989-11-01

    A portable environment radon content device with a 40 liter decay chamber based on the method of Thomas double filter radon content absolute measurement has been developed. The correctness of the method of Thomas double filter absolute measurement has been verified by the experiments to measure the sampling gas density of radon that the theoretical density has been known. In addition, the intrinsic uncertainty of this method is also determined in the experiments. The confidence of this device is about 95%, the sensitivity is better than 0.37 Bqm -3 and the intrinsic uncertainty is less than 10%. The results show that the selected measuring and structure parameters are reasonable and the experimental methods are acceptable. In this method, the influence on the measured values from the radioactive equilibrium of radon and its daughters, the ratio of combination daughters to the total daughters and the fraction of charged particles has been excluded in the theory and experimental methods. The formula of Thomas double filter absolute measuring radon is applicable to the cylinder decay chamber, and the applicability is also verified when the diameter of exit filter is much smaller than the diameter of inlet filter

  20. Cerebral Blood Flow Measurement Using fMRI and PET: A Cross-Validation Study

    Directory of Open Access Journals (Sweden)

    Jean J. Chen

    2008-01-01

    Full Text Available An important aspect of functional magnetic resonance imaging (fMRI is the study of brain hemodynamics, and MR arterial spin labeling (ASL perfusion imaging has gained wide acceptance as a robust and noninvasive technique. However, the cerebral blood flow (CBF measurements obtained with ASL fMRI have not been fully validated, particularly during global CBF modulations. We present a comparison of cerebral blood flow changes (ΔCBF measured using a flow-sensitive alternating inversion recovery (FAIR ASL perfusion method to those obtained using H2O15 PET, which is the current gold standard for in vivo imaging of CBF. To study regional and global CBF changes, a group of 10 healthy volunteers were imaged under identical experimental conditions during presentation of 5 levels of visual stimulation and one level of hypercapnia. The CBF changes were compared using 3 types of region-of-interest (ROI masks. FAIR measurements of CBF changes were found to be slightly lower than those measured with PET (average ΔCBF of 21.5±8.2% for FAIR versus 28.2±12.8% for PET at maximum stimulation intensity. Nonetheless, there was a strong correlation between measurements of the two modalities. Finally, a t-test comparison of the slopes of the linear fits of PET versus ASL ΔCBF for all 3 ROI types indicated no significant difference from unity (P>.05.

  1. Noise thermometry - a new temperature measuring method

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Rittinghaus, K.F.

    1975-01-01

    The thermal Johnson-Niquist noise is the basis of noise thermometry. This temperature measuring method is, e.g., of interest insofar as the noise thermometer gives absolute values as a primary thermometer and is in principle extensively independent of environmental influences and material properties. The resistance values of the measuring probe are about 10 Ohm to a few kOhm. The demands of electronics are high, the self-noise of the measuring apparatus must be as small as possible; a comparative measuring method is advantageous. 1 to 2,500 K are given as a possible temperature range. An accuracy of 0.1% could be achieved in laboratory measurements. Temperature measurements to be used in operation in a few nuclear reactors are mentioned. (HP/LH) [de

  2. A new method to measure vaginal sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. To develop a new method to measure vaginal sensibility. We developed a technique to measure the

  3. Improved method of measurement for outer leak

    International Nuclear Information System (INIS)

    Xu Guang

    2012-01-01

    Pneumatic pipeline is installed for the airborne radioactivity measurement equipment, air tightness and outer leak rate are essential for the testing of the characteristics, both in the national criteria and ISO standards, an improved practical method is available for the measurement of the outer air leak rate based on the engineering experiences for the equipment acceptance and testing procedure. (authors)

  4. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors

    Directory of Open Access Journals (Sweden)

    Shouhei Koyama

    2017-01-01

    Full Text Available We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.

  5. Novel method to leukoreduce murine blood for transfusion: how to reduce animal usage.

    Science.gov (United States)

    Fischer, Dania; Büssow, Julian; Meybohm, Patrick; Zacharowski, Kai; Jennewein, Carla

    2016-01-01

    Basic research on the pathomechanisms of transfusion-related adverse events depends on murine transfusion models, in which leukoreduction (LR) is a prevalent standard. The commonly used neonatal LR filter (LRF) is associated with considerable animal numbers. A more efficient method would help support the guiding principles of "replacement, reduction, refinement" (3Rs). Blood from C57BL/6 and C57BL/6-Tg(UBC-GFP)30Scha/J mice was leukoreduced using (1) a neonatal LRF, (2) a syringe LRF, or (3) CD45 microbeads. Product quality was assessed according to US Food and Drug Administration (FDA) standards. White blood cell numbers were analyzed by flow cytometry; hemoglobin concentrations and hematocrit were measured and in vivo posttransfusion recoveries were determined after 2 weeks of storage. Using the neonatal filter, a LR of 99.56% was achieved with wastage of 12.4 mL in comparison to 99.68% and 1-mL hold-up volume with the syringe filter and 99.11 ± 0.24% LR and 0.1-mL wastage using microbeads. All techniques achieved FDA quality standards, apart from posttransfusion recovery rate, which was only reached by the microbeads-based technique. LR with CD45 microbeads not only reduces animal usage but also provides a more efficacious method regarding posttransfusion red blood cell recovery and, hence, provides a promising alternative to commonly used methods. © 2015 AABB.

  6. A New Method to Measure Vaginal Sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Introduction: Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. Aims: To develop a new method to measure vaginal sensibility. Methods: We

  7. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  8. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  9. Torsion method for measuring piezooptic coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Skab, I.; Smaga, I.; Savaryn, V.; Vasylkiv, Yu.; Vlokh, R. [Institute of Physical Optics, Lviv (Ukraine)

    2011-01-15

    We develop and describe analytically a torsion method for measuring piezooptic coefficients associated with shear stresses. It is shown that the method enables to increase significantly the accuracy of determination of piezooptic coefficients. The method and the appropriate apparatus are verified experimentally on the example of LiNbO{sub 3} crystals. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Methods of radon measurement and devices

    International Nuclear Information System (INIS)

    Miles, J.

    2004-01-01

    The following topics and instrumentation are discussed: The quantity to be measured; Active measurement methods (scintillation cells, ionisation chambers, electrostatic collection of decay products); Passive measurement methods (charcoal detectors; electret ion chambers; etched track detectors); and Detector considerations for large-scale surveys ('always on' or 'switchable' detectors?; response to radon-220; avoidance of electrostatic effects; quality assurance for passive radon detectors; quality control within the laboratory; external quality assurance; detectors need to be easily deliverable). It is concluded that the ideal detector for large scale surveys of radon in houses is a small, closed detector in a conducting holder which excludes radon-220, supported by rigorous quality assurance procedures. (P.A.)

  11. COMPARATIVE ANALYSIS OF BLOOD GROUPING IN HEALTHY BLOOD DONOR USING GEL CARD TECHNIQUE AND TUBE METHOD

    Directory of Open Access Journals (Sweden)

    Muhammad Usman

    2016-12-01

    Full Text Available Blood grouping is a vital test in pre-transfusion testing. Both tube and gel agglutination assays are used for ABO grouping. The main object of this study was to compare ABO grouping and D typing on tube and gel agglutination assay in order to assess the efficacy of each technique. A total of 100 healthy blood donors irrespective of age and sex were included in this study. Results showed that there is no significant difference between these two techniques. However, in 10 samples it was detected that the reaction strength in serum ABO grouping by gel agglutination assay is varied by only one grade when compared to tube agglutination assay. Due to numerous positive effects of gel assay it is more beneficial to implement this technique in the setups where blood banks bear heavy routine work load.

  12. Absolute method of measuring magnetic susceptibility

    Science.gov (United States)

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  13. Method of orthogonally splitting imaging pose measurement

    Science.gov (United States)

    Zhao, Na; Sun, Changku; Wang, Peng; Yang, Qian; Liu, Xintong

    2018-01-01

    In order to meet the aviation's and machinery manufacturing's pose measurement need of high precision, fast speed and wide measurement range, and to resolve the contradiction between measurement range and resolution of vision sensor, this paper proposes an orthogonally splitting imaging pose measurement method. This paper designs and realizes an orthogonally splitting imaging vision sensor and establishes a pose measurement system. The vision sensor consists of one imaging lens, a beam splitter prism, cylindrical lenses and dual linear CCD. Dual linear CCD respectively acquire one dimensional image coordinate data of the target point, and two data can restore the two dimensional image coordinates of the target point. According to the characteristics of imaging system, this paper establishes the nonlinear distortion model to correct distortion. Based on cross ratio invariability, polynomial equation is established and solved by the least square fitting method. After completing distortion correction, this paper establishes the measurement mathematical model of vision sensor, and determines intrinsic parameters to calibrate. An array of feature points for calibration is built by placing a planar target in any different positions for a few times. An terative optimization method is presented to solve the parameters of model. The experimental results show that the field angle is 52 °, the focus distance is 27.40 mm, image resolution is 5185×5117 pixels, displacement measurement error is less than 0.1mm, and rotation angle measurement error is less than 0.15°. The method of orthogonally splitting imaging pose measurement can satisfy the pose measurement requirement of high precision, fast speed and wide measurement range.

  14. Measurement of Uranium in Blood-Plasma of Bavarian Females

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Watling, R.J.

    2011-01-01

    It has recently been reported that the water supply in some parts of Bavaria (Germany) contains Uranium. In order to study its effects we have determined the concentrations of U in the blood plasma of 25 females. All the females came from Bavaria and were not on any medication. Blood samples were drawn from a superficial arm vein, centrifuged and plasma extracted. The plasma samples were freeze-dried and analysed in our Analytical Laboratory in Perth, Western Australia by using the technique of ICP-MS. The U contents found varied from less than 0.1 to 8.2 ppb (6.6 ng/L to 543 ng/L)

  15. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, Menno R.; de Witt Hamer, Philip C.; van Boven, Leonard J.; Zwinderman, Koos A. H.; Bouma, Gerrit J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  16. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US .... Arterial blood pressure from nonvascular access arm was measured by aneroid sphygmomanometer. The patients did not .... to detect differences in treatments across multiple test attempts. P < 0.05 ...

  17. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  18. The Chronic and Acute Effects of Exercise Upon Selected Blood Measures.

    Science.gov (United States)

    Roitman, J. L.; Brewer, J. P.

    This study investigated the effects of chronic and acute exercise upon selected blood measures and indices. Nine male cross-country runners were studied. Red blood count, hemoglobin, and hematocrit were measured using standard laboratory techniques; mean corpuscular volume (MCV), mean corpuscular hemoglobin, and mean corpuscular hemoglobin…

  19. COMPANY PERFORMANCE MEASUREMENT AND REPORTING METHODS

    Directory of Open Access Journals (Sweden)

    Nicu Ioana Elena

    2012-12-01

    Full Text Available One of the priorities of economic research has been and remains the re-evaluation of the notion of performance and especially exploring and finding some indicators that would reflect as accurately as possible the subtleties of the economic entity. The main purpose of this paper is to highlight the main company performance measurement and reporting methods. Performance is a concept that raises many question marks concerning the most accurate or the best method of reporting the performance at the company level. The research methodology has aimed at studying the Romanian and foreign specialized literature dealing with the analyzed field, studying magazines specialized on company performance measurement. If the financial performance measurement indicators are considered to offer an accurate image of the situation of the company, the modern approach through non-financial indicators offers a new perspective upon performance measurement, which is based on simplicity. In conclusion, after the theoretical study, I have noticed that the methods of performance measurement, reporting and interpretation are various, the opinions regarding the best performance measurement methods are contradictive and the companies prefer resorting to financial indicators that still play a more important role in the consolidation of the company performance measurement than the non-financial indicators do.

  20. A simple trapping method to estimate abundances of blood-sucking flying insects in avian nests

    NARCIS (Netherlands)

    Tomás, G.; Merino, S.; Martínez-de la Puente, J.; Moreno, J.; Morales, J.; Lobato, E.

    2008-01-01

    [KEYWORDS: birds; biting midges; blackflies; blood parasite-insect vector-vertebrate host relationships; Ceratopogonidae; Culicoides; distance to water sources; insecticide treatment; sampling methods; Simuliidae

  1. Second measurement of morning systolic blood pressure is more closely associated with albuminuria.

    Science.gov (United States)

    Sakabe, Kazumi; Fukui, Michiaki; Ushigome, Emi; Hamaguchi, Masahide; Tanaka, Toru; Atsuta, Haruhiko; Ohnishi, Masayoshi; Oda, Yohei; Hasegawa, Goji; Nakamura, Naoto

    2012-08-01

    It is important to control blood pressure as well as to control blood glucose for the prevention of diabetic nephropathy. However, to our knowledge, there are no reports investigating which blood pressure, including morning, evening and clinic, is more closely associated with albuminuria and whether one measurement is sufficient or not in patients with Type 2 diabetes. We measured morning, evening and clinic blood pressure and compared the area under the curve (AUC) of blood pressure for urinary albumin excretion equal to or more than 30 mg/g creatinine using receiver-operating characteristic curve analyses and odds ratio for albuminuria defined as urinary albumin excretion equal to or more than 30 mg/g creatinine in 858 patients with Type 2 diabetes. Odds ratio (95% confidence interval (CI)) of morning, evening and clinic systolic blood pressure for albuminuria was 1.034 (1.024 - 1.044), 1.033 (1.023 - 1.043) and 1.013 (1.055 - 1.021), respectively (p AUC of morning, evening and clinic systolic blood pressure was 0.644 (0.628 - 0.700) (p AUC of the second morning systolic blood pressure was greater than the first (p = 0.033). The second measurement of morning systolic blood pressure is more closely associated with albuminuria than the first measurement of the morning in addition to clinic systolic blood pressure.

  2. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1985-08-05

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.

  3. Method and apparatus for automated processing and aliquoting of whole blood samples for analysis in a centrifugal fast analyzer

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.

    1988-01-01

    A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.

  4. Is there a necessity for individual blood water corrections when conductivity-based access blood flow measurements are made?

    Science.gov (United States)

    Huang, Shih-Han S; Heidenheim, Paul A; Gallo, Kerri; Jayakumar, Saumya; Lindsay, Robert M

    2011-01-01

    Access blood water flow rate (Qaw) can be measured during hemodialysis using an online effective ionic dialysance (EID) methodology. Fresenius employ this methodology in their 2008K dialysis machine. The machine computer converts Qaw to an access blood flow rate (Fresenius Qa) using a generic blood water constant (BWC). We wished to validate this BWC. 18 patients had Fresenius Qa measurements using the EID and these were compared with a 'gold standard' ultrasound dilution methodology (Transonic Qa). Qa values were also obtained by removing the BWC from Fresenius Qa values to obtain the Qaw and recorrecting it with individualized patient factors using hematocrit and total protein values (HctTp Qa). The measurements were repeated after 1 h. There were no significant differences between Fresenius and Transonic, nor between HctTp and Transonic Qa values (p > 0.17). There were strong correlations between both sets of values (r > 0.856; p Fresenius Qa pairs (r = 0.573; p > 0.07). It was surmised that the BWC was not valid post-dialysis. The generic BWC is comparable to individualized blood water correction factors when Qa measures are made early in dialysis and prior to ultrafiltration treatment. Copyright © 2011 S. Karger AG, Basel.

  5. Measuring osmosis and hemolysis of red blood cells.

    Science.gov (United States)

    Goodhead, Lauren K; MacMillan, Frances M

    2017-06-01

    Since the discovery of the composition and structure of the mammalian cell membrane, biologists have had a clearer understanding of how substances enter and exit the cell's interior. The selectively permeable nature of the cell membrane allows the movement of some solutes and prevents the movement of others. This has important consequences for cell volume and the integrity of the cell and, as a result, is of utmost clinical importance, for example in the administration of isotonic intravenous infusions. The concepts of osmolarity and tonicity are often confused by students as impermeant isosmotic solutes such as NaCl are also isotonic; however, isosmotic solutes such as urea are actually hypotonic due to the permeant nature of the membrane. By placing red blood cells in solutions of differing osmolarities and tonicities, this experiment demonstrates the effects of osmosis and the resultant changes in cell volume. Using hemoglobin standard solutions, where known concentrations of hemoglobin are produced, the proportion of hemolysis and the effect of this on resultant hematocrit can be estimated. No change in cell volume occurs in isotonic NaCl, and, by placing blood cells in hypotonic NaCl, incomplete hemolysis occurs. By changing the bathing solution to either distilled water or isosmotic urea, complete hemolysis occurs due to their hypotonic effects. With the use of animal blood in this practical, students gain useful experience in handling tissue fluids and calculating dilutions and can appreciate the science behind clinical scenarios. Copyright © 2017 the American Physiological Society.

  6. Ocular Blood Flow Measured Noninvasively in Zero Gravity

    Science.gov (United States)

    Ansari, Rafat R.; Manuel, Francis K.; Geiser, Martial; Moret, Fabrice; Messer, Russell K.; King, James F.; Suh, Kwang I.

    2003-01-01

    In spaceflight or a reduced-gravity environment, bodily fluids shift to the upper extremities of the body. The pressure inside the eye, or intraocular pressure, changes significantly. A significant number of astronauts report changes in visual acuity during orbital flight. To date this remains of unknown etiology. Could choroidal engorgement be the primary mechanism and a change in the curvature or shape of the cornea or lens be the secondary mechanism for this change in visual acuity? Perfused blood flow in the dense meshwork of capillaries of the choroidal tissue (see the preceding illustration) provides necessary nutrients to the outer layers of the retina (photoreceptors) to keep it healthy and maintain good vision. Unlike the vascular system, the choroid has no baroreceptors to autoregulate fluid shifts, so it can remain engorged, pushing the macula forward and causing a hyperopic (farsighted) shift of the eye. Experiments by researchers at the NASA Glenn Research Center could help answer this question and facilitate planning for long-duration missions. We are investigating the effects of zero gravity on the choroidal blood flow of volunteer subjects. This pilot project plans to determine if choroidal blood flow is autoregulated in a reduced-gravity environment.

  7. Measurement of portal blood flow in healthy individuals: a comparison between magnetic resonance imaging and Doppler ultrasound

    International Nuclear Information System (INIS)

    Costa, Juliana Dantas da; Sebastiane, Patricia Moreno; Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; D'Ippolito, Giuseppe

    2008-01-01

    Objective: To evaluate the inter-observer agreement between Doppler ultrasonography and magnetic resonance imaging in the quantification of portal blood flow in healthy individuals, as well as evaluating the reproducibility of both methods. Materials and methods: A prospective, transverse, observational and self-paired study was developed evaluating 20 healthy volunteers whose portal blood flow was measured by means of Doppler ultrasonography and magnetic resonance imaging performed by two independent observers. Interobserver and inter method agreements were calculated using the intra class and Pearson's correlation coefficients. Results: The agreement between Doppler ultrasonography and magnetic resonance imaging was low (intra class coefficient: 1.9%-18.2%; Pearson's coefficient: 0.1%-13.7%; p=0.565). Mean values for the portal blood flow measured by Doppler ultrasonography and magnetic resonance imaging were respectively 0.768 l/min and 0.742 l/min. Interobserver agreement for quantification of the portal blood flow by Doppler ultrasonography and magnetic resonance imaging was respectively reasonable (intra class coefficient: 43.3%; Pearson's coefficient: 43.0%) and excellent (intra class coefficient: 91.4%; Pearson's coefficient: 93.4%). Conclusion: In the present study, magnetic resonance imaging demonstrated to be a reliable method for quantifying the portal blood flow, with a higher interobserver agreement than Doppler ultrasonography. The inter method agreement was low. (author)

  8. Evaluation of the correlation between transcutaneous measurement andconcentration ofbilirubin inthe blood serum ofa newborn

    Directory of Open Access Journals (Sweden)

    Małgorzata Morawiecka-Pietrzak

    2016-09-01

    Full Text Available Aim: Due to the potential toxicity of high concentrations of bilirubin, newborns are monitored in terms of the potential emergence of a group at risk of the development of severe hyperbilirubinaemia and, rarely, encephalopathy and kernicterus. The transcutaneous measurement of bilirubin, as a non-invasive method, is applied in neonatal centres. The paper presents an evaluation of the correlation between the transcutaneous measurement and the concentration of bilirubin in the blood serum of a newborn, taking into consideration the reduction of the necessity to carry out blood tests related to the transcutaneous measurement. Material and method: The analysis comprised 1,076 medical histories of newborns hospitalised at the Department of Neonatology of the Municipal Hospital in Zabrze in the period from 1 January to 31 December 2013 (a primary referral centre. The inclusion criteria for the study were: performing a simultaneous transcutaneous measurement and a blood serum concentration measurement of bilirubin, gestational age ≥35 Hbd and birth weight >2,500 g. 272 children were qualified for the study. Results: Boys constituted 51.7%, and girls 48.3% of the research group. The mean gestational age was 38.7 Hbd and the mean birth weight was 3,323.4 g; 67.8% of the children were born by natural labour and 32.2% – by caesarean section. The mean Apgar score in the 5th minute was 9.8 points. The measurement of the concentration of bilirubin was performed on average on the 3.9 day of life. The mean transcutaneous measurement was 9.67 mg% (2.7–17.2 mg% and the mean concentration of bilirubin in the blood serum was 13.18 mg% (7.0–19.8 mg%; the difference was 3.5 mg% (p < 0.0001. A statistically significant positive correlation was found between the concentrations of bilirubin obtained in the transcutaneous measurement and the concentrations in the blood serum (according to Spearman, r

  9. Track detection methods of radium measurements

    International Nuclear Information System (INIS)

    Somogyi, G.

    1986-06-01

    The principles of tack formation and processing including the description of etching and etch-track evaluation for the preferably used plastic track detectors are discussed. Measuring methods to determine 226 Ra activity based either on the mapping of alpha-decaying elements in the complete U-Ra series by alpha-radiography, or on the measurement of uranium alone by neutron induced fissionography, or on the alpha-decay measurement of 222 Rn, the first daughter element of radium, and finally on the measurement of alpha-tracks originating from radium itself, which is separated from its parent nuclides are described in detail. (V.N.)

  10. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  11. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before...... ventilation with the CO gas mixture. The amount of CO administered during each determination of CBV resulted in an increase in the CO saturation of hemoglobin of 2.1%-3.9%. A theoretical noise propagation analysis was performed by means of the Monte Carlo method. The analysis showed that a CO dose...... patients. The coefficients of variation were 6.2% and 4.7% in healthy and diseased subjects, respectively. Furthermore, the day-to-day variation of the method with respect to the total amount of circulating hemoglobin (nHb) and CBV was determined from duplicate estimates separated by 24-48 h. In conclusion...

  12. Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation

    Directory of Open Access Journals (Sweden)

    Fen Chen

    2018-03-01

    Full Text Available Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD, acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO method and twelve-layer concentric objects (TLCO method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia.

  13. Remote Blood Pressure Waveform Sensing Method and Apparatus

    Science.gov (United States)

    2008-06-02

    test the effects of drugs, exercise, or other stimuli, whereby an increase or decrease in the ratio may indicate an improvement or worsening of systolic...even though high blood pressure in animals can be symptomatic of a variety of diseases including chronic renal failure, hyperthyroidism , Cushing’s

  14. Cutaneous blood flow. A comparative study between the thermal recovery method and the radioxenon clearance method

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, C M; Ferreira, J M; Fernandes, F V

    1975-01-01

    Since 1968 a thermal recovery method to study the cutaneous circulation has been utilized in the detection of skin circulation changes caused by certain pharmacological agents or by some pathological conditions. This method is based in the determination of the thermal recuperation of a small area of the skin previously cooled. In this work, we want to present the results of a comparative analysis between the thermal recovery method and the clearance of the radioactive xenon injected intracutaneously. The study was performed in the distal extremity of the lower limbs in 16 normal subjects, 16 hyperthyroid patients with increased cutaneous temperature and 11 patients with presumably low cutaneous blood flow (3 patients with hypothyroidism and 8 with obstructive arteriosclerosis).

  15. Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM.

    Science.gov (United States)

    Graves, John W; Grossardt, Brandon R

    2010-06-01

    Guidelines for office blood pressure (BP) measurements recommend two or more readings at each visit. It has been suggested that discarding the first reading may improve the diagnostic utility of office readings. We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings. We studied measurements in 313 mildly hypertensive patients (181 men, median age 51 years) at the end of the washout phase of a hypertension treatment trial. All patients had three auscultatory readings by a trained nurse using a mercury manometer before a 24-h ABPM and three automated readings (Omron 705 CP) to American Heart Association standards after ABPM. Daytime ABPM (09:00-21:00) of systolic BP and diastolic BP were compared with office methods using first only, second and third only, and all three readings. Associations were assessed using Bland-Altman plots and Pearson's correlations. Bland-Altman plots revealed no differences between office methods and daytime ABPM regardless of whether the first reading was included or discarded. Results were similar for both systolic BP and diastolic BP. The Pearson correlations of office method readings with ABPM readings were lowest using the first measurement alone; however, discarding the first measurement did not improve the correlation compared with using all three readings. Discarding the first office BP reading does not change the association of office BP with ABPM or improve the correlation with ABPM values in hypertensive patients.

  16. Methods of viscosity measurements in sealed ampoules

    Science.gov (United States)

    Mazuruk, Konstantin

    1999-07-01

    Viscosity of semiconductors and metallic melts is usually measured by oscillating cup method. This method utilizes the melts contained in vacuum sealed silica ampoules, thus the problems related to volatility, contamination, and high temperature and pressure can be alleviate. In a typical design, the time required for a single measurement is of the order of one hour. In order to reduce this time to a minute range, a high resolution angular detection system is implemented in our design of the viscometer. Furthermore, an electromagnet generating a rotational magnetic field (RMF) is incorporated into the apparatus. This magnetic field can be used to remotely and nonintrusively measure the electrical conductivity of the melt. It can also be used to induce a well controlled rotational flow in the system. The transient behavior of this flow can potentially yield of the fluid. Based on RMF implementation, two novel viscometry methods are proposed in this work: a) the transient torque method, b) the resonance method. A unified theoretical approach to the three methods is presented along with the initial test result of the constructed apparatus. Advantages of each of the method are discussed.

  17. Human performance assessment: methods and measures

    International Nuclear Information System (INIS)

    Andresen, Gisle; Droeivoldsmo, Asgeir

    2000-10-01

    The Human Error Analysis Project (HEAP) was initiated in 1994. The aim of the project was to acquire insights on how and why cognitive errors occur when operators are engaged in problem solving in advanced integrated control rooms. Since human error had not been studied in the HAlden Man-Machine LABoratory (HAMMLAB) before, it was also necessary to carry out research in methodology. In retrospect, it is clear that much of the methodological work is relevant to human-machine research in general, and not only to research on human error. The purpose of this report is, therefore, to give practitioners and researchers an overview of the methodological parts of HEAP. The scope of the report is limited to methods used throughout the data acquisition process, i.e., data-collection methods, data-refinement methods, and measurement methods. The data-collection methods include various types of verbal protocols, simulator logs, questionnaires, and interviews. Data-refinement methods involve different applications of the Eyecon system, a flexible data-refinement tool, and small computer programs used for rearranging, reformatting, and aggregating raw-data. Measurement methods involve assessment of diagnostic behaviour, erroneous actions, complexity, task/system performance, situation awareness, and workload. The report concludes that the data-collection methods are generally both reliable and efficient. The data-refinement methods, however, should be easier to use in order to facilitate explorative analyses. Although the series of experiments provided an opportunity for measurement validation, there are still uncertainties connected to several measures, due to their reliability still being unknown. (Author). 58 refs.,7 tabs

  18. The variability of piezoelectric measurements. Material and measurement method contributions

    International Nuclear Information System (INIS)

    Stewart, M.; Cain, M.

    2002-01-01

    The variability of piezoelectric materials measurements has been investigated in order to separate the contributions from intrinsic instrumental variability, and the contributions from the variability in materials. The work has pinpointed several areas where weaknesses in the measurement methods result in high variability, and also show that good correlation between piezoelectric parameters allow simpler measurement methods to be used. The Berlincourt method has been shown to be unreliable when testing thin discs, however when testing thicker samples there is a good correlation between this and other methods. The high field permittivity and low field permittivity correlate well, so tolerances on low field measurements would predict high field performance. In trying to identify microstructural origins of samples that behave differently to others within a batch, no direct evidence was found to suggest that outliers originate from either differences in microstructure or crystallography. Some of the samples chosen as maximum outliers showed pin-holes, probably from electrical breakdown during poling, even though these defects would ordinarily be detrimental to piezoelectric output. (author)

  19. Evaluation of an Electrochemical Point-of-Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Townsend, J R; Messick, J B; Constable, P D

    2015-01-01

    The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. The primary objective was to determine the accuracy of the meter for measuring plasma [gluc] in dairy cattle. Secondary objectives were to characterize the influence of hematocrit and sample temperature on the measured value for [gluc]. A total of 106 periparturient Holstein-Friesian cattle. Blood and plasma samples (1,109) were obtained and Deming regression and Bland-Altman plots were used to determine the accuracy of the meter against the reference method (plasma hexokinase assay). Multivariable regression and linear regression were used to determine the effect of hematocrit and sample temperature on the plasma [gluc] measured by the meter. Intra-erythrocyte [gluc] was 18% of plasma [gluc] on a molar basis. Sample temperature had a significant linear effect on plasma [gluc] as measured by the meter for 3/5 plasma samples when measured [gluc] > 160 mg/dL. The meter utilizes an algorithm that is optimized for human blood and is inaccurate when applied to bovine blood. Until a cattle-specific algorithm is developed, we recommend using plasma as the analyte instead of blood and calculating plasma [gluc] using the equation: [gluc] = 0.66 × [gluc]p-meter + 15, where [gluc]p-meter is the value reported by the meter. If blood is measured, then we recommend using the equation: [gluc] = 0.90 × [gluc]b-meter + 15. Copyright © 2015 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  20. Challenges in standardization of blood pressure measurement at the population level.

    Science.gov (United States)

    Tolonen, Hanna; Koponen, Päivikki; Naska, Androniki; Männistö, Satu; Broda, Grazyna; Palosaari, Tarja; Kuulasmaa, Kari

    2015-04-10

    Accurate blood pressure measurements are needed in clinical practice, intervention studies and health examination surveys. Blood pressure measurements are sensitive: their accuracy can be affected by measurement environment, behaviour of the subject, measurement procedures, devices used for the measurement and the observer. To minimize errors in blood pressure measurement, a standardized measurement protocol is needed. The European Health Examination Survey (EHES) Pilot project was conducted in 2009-2012. A pilot health examination survey was conducted in 12 countries using a standardized protocol. The measurement protocols used in each survey, training provided for the measurers, measurement data, and observations during site visits were collected and evaluated to assess the level of standardization. The EHES measurement protocol for blood pressure was followed accurately in all 12 pilot surveys. Most of the surveys succeeded in organizing a quiet and comfortable measurement environment, and staff instructed survey participants appropriately before examination visits. In all surveys, blood pressure was measured three times, from the right arm in a sitting posture. The biggest variation was in the device used for the blood pressure measurement. It is possible to reach a high level of standardization for blood pressure measurements across countries and over time. A detailed, standardized measurement protocol, and adequate training and monitoring during the fieldwork and centrally organized quality assessment of the data are needed. The recent EU regulation banning the sale of mercury sphygmomanometer in European Union Member States has set new challenges for the standardization of measurement devices since the validity of oscillometric measurements is device-specific and performance of aneroid devices depends very much on calibration.

  1. IFCC reference measurement procedure for substance concentration determination of total carbon dioxide in blood, plasma or serum

    NARCIS (Netherlands)

    Burnett, RW; Covington, AK; Fogh-Andersen, N; Kulpmann, WR; Lewenstam, A; Mas, AHJ; VanKessel, AL; Zijlstra, WG

    A reference measurement procedure for substance concentration determination of total CO, in blood, plasma (the anticoagulant is usually heparin) or serum is described. The document covers the principle of the method, the materials and equipment needed and essential aspects of the procedure. The

  2. Thirty years of research on diagnostic and therapeutic thresholds for the self-measured blood pressure at home.

    NARCIS (Netherlands)

    Staessen, J.A.; Thijs, L.; Ohkubo, T.; Kikuya, M.; Richart, T.; Boggia, J.; Adiyaman, A.; Dechering, D.G.; Kuznetsova, T.; Thien, Th.; Leeuw, P. de; Imai, Y.; O'brien, E.; Parati, G.

    2008-01-01

    OBJECTIVE: The goal of this review study is to summarize 30 years of research on cut-off limits for the self-measured blood pressure. METHODS: We reviewed two meta-analyses, several prospective outcome studies in populations and hypertensive patients, studies in pregnant women, three clinical trials

  3. Adherence to blood pressure measurement guidelines in long-term care facilities: A cross sectional study.

    Science.gov (United States)

    Ozone, Sachiko; Sato, Mikiya; Takayashiki, Ayumi; Sakamoto, Naoto; Yoshimoto, Hisashi; Maeno, Tetsuhiro

    2018-05-01

    To assess the extent to which long-term care facilities in Japan adhere to blood pressure (BP) measurement guidelines. Cross-sectional, observational survey. Japan (nationwide). Geriatric health service facilities that responded to a questionnaire among 701 facilities that provide short-time daycare rehabilitation services in Japan. A written questionnaire that asked about types of measurement devices, number of measurements used to obtain an average BP, resting time prior to measurement, and measurement methods when patients' arms were covered with thin (eg, a light shirt) or thick sleeves (eg, a sweater) was administered. Proportion of geriatric health service facilities adherent to BP measurement guidelines. The response rate was 63.2% (443/701). Appropriate upper-arm BP measurement devices were used at 302 facilities (68.2%). The number of measurements was appropriate at 7 facilities (1.6%). Pre-measurement resting time was appropriate (≥5 minutes) at 205 facilities (46.3%). Of the 302 facilities that used appropriate BP measurement devices, 4 (1.3%) measured BP on a bare arm if it was covered with a thin sleeve, while 266 (88.1%) measured BP over a thin sleeve. When arms were covered with thick sleeves, BP was measured on a bare arm at 127 facilities (42.1%) and over a sleeve at 78 facilities (25.8%). BP measurement guidelines were not necessarily followed by long-term care service facilities in Japan. Modification of guidelines regarding removing thick sweaters and assessing BP on a visit-to-visit basis might be needed.

  4. Methods and Devices used to Measure Friction

    DEFF Research Database (Denmark)

    Jeswiet, Jack; Arentoft, Mogens; Henningsen, Poul

    2004-01-01

    . To gain a good understanding of the mechanisms at the interface and to be able to verify the friction and tribology models that exist, friction sensors are needed. Designing sensors to measure friction-stress in metal working has been pursued by many researchers. This paper surveys methods, which have...... been tried in the past and discusses some of the recent sensor designs, which can now be used to measure Friction in both production situations and for research purposes....

  5. Three methods to measure RH bond energies

    International Nuclear Information System (INIS)

    Berkowitz, J.; Ellison, G.B.; Gutman, D.

    1993-01-01

    In this paper the authors compare and contrast three powerful methods for experimentally measuring bond energies in polyatomic molecules. The methods are: radical kinetics; gas phase acidity cycles; and photoionization mass spectroscopy. The knowledge of the values of bond energies are a basic piece of information to a chemist. Chemical reactions involve the making and breaking of chemical bonds. It has been shown that comparable bonds in polyatomic molecules, compared to the same bonds in radicals, can be significantly different. These bond energies can be measured in terms of bond dissociation energies

  6. Statistical methods towards more efficient infiltration measurements.

    Science.gov (United States)

    Franz, T; Krebs, P

    2006-01-01

    A comprehensive knowledge about the infiltration situation in a catchment is required for operation and maintenance. Due to the high expenditures, an optimisation of necessary measurement campaigns is essential. Methods based on multivariate statistics were developed to improve the information yield of measurements by identifying appropriate gauge locations. The methods have a high degree of freedom against data needs. They were successfully tested on real and artificial data. For suitable catchments, it is estimated that the optimisation potential amounts up to 30% accuracy improvement compared to nonoptimised gauge distributions. Beside this, a correlation between independent reach parameters and dependent infiltration rates could be identified, which is not dominated by the groundwater head.

  7. Environmental Chemicals in Urine and Blood: Improving Methods for Creatinine and Lipid Adjustment

    Science.gov (United States)

    O’Brien, Katie M.; Upson, Kristen; Cook, Nancy R.; Weinberg, Clarice R.

    2015-01-01

    Background Investigators measuring exposure biomarkers in urine typically adjust for creatinine to account for dilution-dependent sample variation in urine concentrations. Similarly, it is standard to adjust for serum lipids when measuring lipophilic chemicals in serum. However, there is controversy regarding the best approach, and existing methods may not effectively correct for measurement error. Objectives We compared adjustment methods, including novel approaches, using simulated case–control data. Methods Using a directed acyclic graph framework, we defined six causal scenarios for epidemiologic studies of environmental chemicals measured in urine or serum. The scenarios include variables known to influence creatinine (e.g., age and hydration) or serum lipid levels (e.g., body mass index and recent fat intake). Over a range of true effect sizes, we analyzed each scenario using seven adjustment approaches and estimated the corresponding bias and confidence interval coverage across 1,000 simulated studies. Results For urinary biomarker measurements, our novel method, which incorporates both covariate-adjusted standardization and the inclusion of creatinine as a covariate in the regression model, had low bias and possessed 95% confidence interval coverage of nearly 95% for most simulated scenarios. For serum biomarker measurements, a similar approach involving standardization plus serum lipid level adjustment generally performed well. Conclusions To control measurement error bias caused by variations in serum lipids or by urinary diluteness, we recommend improved methods for standardizing exposure concentrations across individuals. Citation O’Brien KM, Upson K, Cook NR, Weinberg CR. 2016. Environmental chemicals in urine and blood: improving methods for creatinine and lipid adjustment. Environ Health Perspect 124:220–227; http://dx.doi.org/10.1289/ehp.1509693 PMID:26219104

  8. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Directory of Open Access Journals (Sweden)

    Nickenig Georg

    2009-05-01

    Full Text Available Abstract Background Wrist blood pressure (BP devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP measurement methods: 1 office BP, 2 home BP (Omron wrist device HEM- 637 IT with position sensor, 3 24-hour ambulatory BP(24-h ABPM (ABPM-04, Meditech, Hunconventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have to be used cautious and with defined limitations, the use of validated devices with position sensor according to recently recommended measurement schedules might have the potential to be used for therapy monitoring.

  9. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index

    Directory of Open Access Journals (Sweden)

    Moreira Leila B

    2010-11-01

    Full Text Available Abstract Background Blood pressure (BP variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM. We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI. Methods and Results In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time, standard deviation (SD of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40 was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007. In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04. In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P Conclusion Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  10. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    Energy Technology Data Exchange (ETDEWEB)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S. (Departments of Anaesthesiology, Obstetrics and Gynaecology and Medical Physics, Karolinska Institute at Huddinge University Hospital, Stockholm (Sweden))

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author).

  11. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    International Nuclear Information System (INIS)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S.

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author)

  12. Measurement of cerebral blood flow in normal subjects by phase contrast MR imaging

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Inoue, Yusuke; Osada, Hisato

    1994-01-01

    Global cerebral blood flow (CBF) was quantitatively measured with a two-dimensional phase contrast cine magnetic resonance (MR) imaging technique in 24 normal subjects (mean age, 38.6 years; range, 12-70 years). Cine transverse images of the upper cervical region (32 phases/cardiac cycle) were acquired with a 1.5 Tesla MR imaging unit. In five subjects, measurement of CBF was performed before and after intravenous administration of acetazolamide (DIAMOX, 15 mg/kg). Inter- and intra-observer variations in flow volume measurement were small (r=0.970, standard error of the estimate (SEE)=2.9 ml/min, n=8; r=0.963, SEE=4.6 ml/min, n=40, respectively). In measuring flow velocity, they were inferior to those of flow volume measurement. On a visually determined setting of region of interest (ROI), reproducibility of the measurement of flow velocity was not satisfactory in this study. Thus only the results of flow volume measurement are presented. Mean summed vertebral flow volume (171 ml/min, SD=40.6) was significantly less than mean summed internal carotid flow volume (523 ml/min, SD=111). Total blood flow volume showed a significant decline with age (r=-0.45, p<0.05). The mean proportions of carotid and vertebral flow volume to total flow volume were 75.3% and 24.7%, respectively, and showed no significant change with age. The left-to-right ratio of vertebral flow volume (1.39) was significantly higher than that of internal carotid flow volume (0.99, r=0.05). After DIAMOX i.v., the mean rate of increase in total flow volume was 157%. Mean rates of increase in carotid and vertebral flow volume were 154% and 166%, respectively, which were not significantly different. In conclusion, this method is useful for estimating carotid and vertebral flow volume. (author)

  13. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  14. Method of superconducting joint and its measurement

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Lee, Ho Jin; Hong, Gye Won

    1994-04-01

    The development of joint techniques for superconducting wires is essential to fabricate the high quality superconducting magnet. In this report, the various joining methods and their measuring techniques were reviewed. In order to fabricate a precise superconducting magnet, joining and measuring experiment by using the field decay technique carried out. The contact resistance of coupled specimens with joint was measured as 3.0 x 10 -15 ohm at 1 Tesla which is lower than that of the real operating condition of MRI magnet. It is expected that these data can be used to design and fabricate the superconducting magnets successfully. (Author) 12 refs., 20 figs., 2 tabs

  15. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network.

    Science.gov (United States)

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network including a rat, a reservoir, a pinch valve, and a peristaltic pump. To demonstrate the proposed method, a twin-shaped microfluidic device, which is composed of two half-circular chambers, two side channels with multiple indicating channels, and one bridge channel, was carefully designed. Based on the microfluidic device, three sequential flow controls were applied to identify viscosity and flow rate of blood, with label-free and sensorless detection. The half-circular chamber was employed to achieve mechanical membrane compliance for flow stabilization in the microfluidic device. To quantify the effect of flow stabilization on flow fluctuations, a formula of pulsation index (PI) was analytically derived using a discrete fluidic circuit model. Using the PI formula, the time constant contributed by the half-circular chamber is estimated to be 8 s. Furthermore, flow fluctuations resulting from the peristaltic pumps are completely removed, especially under periodic flow conditions within short periods (T viscosity with respect to varying flow rate conditions [(a) known blood flow rate via a syringe pump, (b) unknown blood flow rate via a peristaltic pump]. As a result, the flow rate and viscosity of blood can be simultaneously measured with satisfactory accuracy. In addition, the proposed method was successfully applied to identify the viscosity of rat blood, which circulates in a complex fluidic network. These observations confirm that the proposed method can be used for

  16. Deformability measurement of red blood cells using a microfluidic channel array and an air cavity in a driving syringe with high throughput and precise detection of subpopulations.

    Science.gov (United States)

    Kang, Yang Jun; Ha, Young-Ran; Lee, Sang-Joon

    2016-01-07

    Red blood cell (RBC) deformability has been considered a potential biomarker for monitoring pathological disorders. High throughput and detection of subpopulations in RBCs are essential in the measurement of RBC deformability. In this paper, we propose a new method to measure RBC deformability by evaluating temporal variations in the average velocity of blood flow and image intensity of successively clogged RBCs in the microfluidic channel array for specific time durations. In addition, to effectively detect differences in subpopulations of RBCs, an air compliance effect is employed by adding an air cavity into a disposable syringe. The syringe was equally filled with a blood sample (V(blood) = 0.3 mL, hematocrit = 50%) and air (V(air) = 0.3 mL). Owing to the air compliance effect, blood flow in the microfluidic device behaved transiently depending on the fluidic resistance in the microfluidic device. Based on the transient behaviors of blood flows, the deformability of RBCs is quantified by evaluating three representative parameters, namely, minimum value of the average velocity of blood flow, clogging index, and delivered blood volume. The proposed method was applied to measure the deformability of blood samples consisting of homogeneous RBCs fixed with four different concentrations of glutaraldehyde solution (0%-0.23%). The proposed method was also employed to evaluate the deformability of blood samples partially mixed with normal RBCs and hardened RBCs. Thereafter, the deformability of RBCs infected by human malaria parasite Plasmodium falciparum was measured. As a result, the three parameters significantly varied, depending on the degree of deformability. In addition, the deformability measurement of blood samples was successfully completed in a short time (∼10 min). Therefore, the proposed method has significant potential in deformability measurement of blood samples containing hematological diseases with high throughput and precise detection of

  17. A liquid chromatographic method for determination of theophylline in serum and capillary blood--a comparison.

    Science.gov (United States)

    Gartzke, J; Jäger, H; Vins, I

    1991-01-01

    A simple, fast and reliable liquid chromatographic method for the determination of theophylline in serum and capillary blood after a solid phase extraction is described for therapeutic drug monitoring. The employment of capillary blood permits the determination of an individual drug profile and other pharmacokinetic studies in neonates and infants. There were no differences in venous- and capillary-blood levels but these values compared poorly with those in serum. An adjustment of the results by correction of the different volumes of serum and blood by haematocrit was unsuccessful. Differences in the binding of theophylline to erythrocytes could be an explanation for the differences in serum at blood levels of theophylline.

  18. Measurement methods of building structures deflections

    Directory of Open Access Journals (Sweden)

    Wróblewska Magdalena

    2018-01-01

    Full Text Available Underground mining exploitation is leading to the occurrence of deformations manifested by, in particular, sloping terrain. The structures situated on the deforming subsoil are subject to uneven subsidence which is leading in consequence to their deflection. Before a building rectification process takes place by, e.g. uneven raising, the structure's deflection direction and value is determined so that the structure is restored to its vertical position as a result of the undertaken remedial measures. Deflection can be determined by applying classical as well as modern measurement techniques. The article presents examples of measurement methods used considering the measured elements of building structures’ constructions and field measurements. Moreover, for a given example of a mining area, the existing deflections of buildings were compared with mining terrain sloping.

  19. The effect of hemiplegia on blood pressure measurement in the elderly.

    OpenAIRE

    Dewar, R.; Sykes, D.; Mulkerrin, E.; Nicklason, F.; Thomas, D.; Seymour, R.

    1992-01-01

    The blood pressure in both arms of 103 unselected hemiplegic patients was measured using a random-zero sphygmomanometer. Although for the whole sample the mean blood pressure in the paretic and unaffected arm was similar, a significant difference was found when the patients were subdivided according to the tone of the arm. The blood pressure was higher in paretic arms of patients with a spastic stroke and lower in the affected arm if the tone was flaccid. No other characteristics were associa...

  20. Reproduction of pressure field in ultrasonic-measurement-integrated simulation of blood flow.

    Science.gov (United States)

    Funamoto, Kenichi; Hayase, Toshiyuki

    2013-07-01

    Ultrasonic-measurement-integrated (UMI) simulation of blood flow is used to analyze the velocity and pressure fields by applying feedback signals of artificial body forces based on differences of Doppler velocities between ultrasonic measurement and numerical simulation. Previous studies have revealed that UMI simulation accurately reproduces the velocity field of a target blood flow, but that the reproducibility of the pressure field is not necessarily satisfactory. In the present study, the reproduction of the pressure field by UMI simulation was investigated. The effect of feedback on the pressure field was first examined by theoretical analysis, and a pressure compensation method was devised. When the divergence of the feedback force vector was not zero, it influenced the pressure field in the UMI simulation while improving the computational accuracy of the velocity field. Hence, the correct pressure was estimated by adding pressure compensation to remove the deteriorating effect of the feedback. A numerical experiment was conducted dealing with the reproduction of a synthetic three-dimensional steady flow in a thoracic aneurysm to validate results of the theoretical analysis and the proposed pressure compensation method. The ability of the UMI simulation to reproduce the pressure field deteriorated with a large feedback gain. However, by properly compensating the effects of the feedback signals on the pressure, the error in the pressure field was reduced, exhibiting improvement of the computational accuracy. It is thus concluded that the UMI simulation with pressure compensation allows for the reproduction of both velocity and pressure fields of blood flow. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Heat-washout measurements compared to distal blood pressure and perfusion in orthopaedic patients with foot ulcers

    DEFF Research Database (Denmark)

    Midttun, M; Azad, B B S; Broholm, R

    2015-01-01

    Distal blood pressure and local skin perfusion pressure were compared to measurement of blood flow rate (BFR) measured by the heat-washout method in orthopaedic patients with and without diabetes, all with a foot ulcer in one foot, compared to healthy controls. The correlation was good between heat......-washout and distal blood pressure in patients with diabetes with and without an ulcer (P = 0·024 and 0·059, respectively). The correlation was weak in patients without diabetes with and without an ulcer, most probably due to power problems (P = 0·118 and 0·116, respectively). The correlation in the healthy controls...... the surrounding tissue, and therefore, measurements are easier made in these subjects. BFR in the first toe increased significantly in all patients when the foot was moved from heart level to 50 cm below heart level (P = between 0·03 and 0·05) as previously seen in patients with claudication...

  2. Acoustic methods for measuring bullet velocity

    OpenAIRE

    Courtney, Michael

    2008-01-01

    This article describes two acoustic methods to measure bullet velocity with an accuracy of 1% or better. In one method, a microphone is placed within 0.1 m of the gun muzzle and a bullet is fired at a steel target 45 m away. The bullet's flight time is the recorded time between the muzzle blast and sound of hitting the target minus the time for the sound to return from the target to the microphone. In the other method, the microphone is placed equidistant from both the gun muzzle and the stee...

  3. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  4. Optical measurement of blood flow in exercising skeletal muscle: a pilot study

    Science.gov (United States)

    Wang, Detian; Baker, Wesley B.; Parthasarathy, Ashwin B.; Zhu, Liguo; Li, Zeren; Yodh, Arjun G.

    2017-07-01

    Blood flow monitoring during rhythm exercising is very important for sports medicine and muscle dieases. Diffuse correlation spectroscopy(DCS) is a relative new invasive way to monitor blood flow but suffering from muscle fiber motion. In this study we focus on how to remove exercise driven artifacts and obtain accurate estimates of the increase in blood flow from exercise. Using a novel fast software correlator, we measured blood flow in forearm flexor muscles of N=2 healthy adults during handgrip exercise, at a sampling rate of 20 Hz. Combining the blood flow and acceleration data, we resolved the motion artifact in the DCS signal induced by muscle fiber motion, and isolated the blood flow component of the signal from the motion artifact. The results show that muscle fiber motion strongly affects the DCS signal, and if not accounted for, will result in an overestimate of blood flow more than 1000%. Our measurements indicate rapid dilation of arterioles following exercise onset, which enabled blood flow to increase to a plateau of 200% in 10s. The blood flow also rapidly recovered to baseline following exercise in 10s. Finally, preliminary results on the dependence of blood flow from exercise intensity changes will be discussed.

  5. Measurement of Finger Blood Flow in Raynauds Phenomenon by Radionuclide Angiography

    International Nuclear Information System (INIS)

    Lim, Sang Moo; Chung, June Key; Lee, Myung Chul; Kim, Sang Joon; Choi, Sung Jae; Koh, Chang Soon

    1987-01-01

    In Raynauds phenomenon, the authors measured finger blood flow after ice water exposure by analyzing the time activity curve of radionuclide angiography on both hands. The results were as follows: 1) The digital blood flow did not decrease after ice water exposure in normal subjects. 2) In the patients with Raynauds phenomenon, there were two groups: the one had decreased digital blood flow after cold exposure, and the other had paradoxically increased digital blood flow after cold exposure. 3) There was no difference in the digital blood flow of hand in room temperature between the normal and the patients with reduced digital blood flow after cold exposure, but the digital blood flow of the hand in room temperature was markedly reduced in the patients with paradoxically increased flow after cold exposure. 4) In the static image the difference was not significant in comparison with the dynamic study, because it represents pooling of the blood in the vein rather than flow. 5) After the treatment with nifedipine, the digital blood flow increased. In conclusion, the radionuclide angiography was useful in measuring the digital blood flow in Raynauds phenomenon, and further studies with various drugs is expected.

  6. Cerebral blood flow measurement techniques in infants and children

    International Nuclear Information System (INIS)

    Kirsch, J.R.; Traystman, R.J.; Rogers, M.C.

    1985-01-01

    The tremendous growth of interest in neurologic intensive care and in the pathophysiology of the cerebral circulation in the past few years has resulted in increasing numbers of studies that document alterations in cerebral flow during the course of various diseases or as a response to treatment of them. Before pediatricians come to conclusions based on these studies, it is important to have an understanding of the techniques involved. The techniques are complex and difficult but are based on understandable principles. They also have limitations and are subject to misinterpretations. Pediatricians should become knowledgeable about some of these techniques and their limitations because it is likely that they will be applied with increasing frequency in the next several years. We are on the threshold of exciting discoveries in abnormalities of cerebral blood flow and cerebral metabolism not only in critically ill children but also in children with congenital and learning disorders

  7. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

    Science.gov (United States)

    Aarnes, Turi K; Hubbell, John A E; Lerche, Phillip; Bednarski, Richard M

    2012-08-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was -9.9 ± 21.9 mmHg with a range of -76 to 54 mmHg, and the 95% limits of agreement (LOA) were -33 to 53 mmHg. The difference between DABP measurements was -1.8 ± 15.6 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -32 to 29 mmHg. The difference between MABP measurements was -2.9 ± 17.0 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -30 to 36 mmHg. Accurate ABP monitoring in anesthetized camelids cannot be accomplished using the oscillometric method.

  8. Radiometric measuring method for egg shells

    Energy Technology Data Exchange (ETDEWEB)

    Forberg, S; Svaerdstroem, K

    1973-02-01

    A description is given of a fast nondestructive radiometric method for registration of the thickness of egg shells of the tawny owl, hen, osprey, and Canada goose. Certain errors are discussed. Measurement of the thickness of egg shells (mineral content per cm/sup 2/) with an accuracy better than 1% is possible in less than one minute under field conditions. (auth)

  9. Gamma spectrometric methods for measuring plutonium

    International Nuclear Information System (INIS)

    Gunnink, R.

    1978-01-01

    Nondestructive analyses of plutonium can be made by detecting and measuring the gamma rays emitted by a sample. Although qualitative and semiquantitative assays can be performed with relative ease, only recently have methods been developed, using computer analysis techniques, that provide quantitative results. This paper reviews some new techniques developed for measuring plutonium. The features of plutonium gamma-ray spectra are reviewed and some of the computer methods used for spectrum analysis are discussed. The discussion includes a description of a powerful computer method of unfolding complex peak multiplets that uses the standard linear least-squares techniques of data analysis. This computer method is based on the generation of response profiles for the isotopes composing a plutonium sample and requires a description of the peak positions, relative intensities, and line shapes. The principles that plutonium isotopic measurements are based on are also developed, followed by illustrations of the measurement procedures as applied to the quantitative analysis of plutonium liquid and solid samples

  10. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  11. Method for the measurement of susceptibility to decubitus ulcer formation.

    Science.gov (United States)

    Meijer, J H; Schut, G L; Ribbe, M W; Goovaerts, H G; Nieuwenhuys, R; Reulen, J P; Schneider, H

    1989-09-01

    A method for measuring the susceptibility of a patient to develop decubitus ulcers is described and initially evaluated. It is based on an indirect, noninvasive measurement of the transient regional blood flow response after a test pressure load which simulates the external stimulus for pressure-sore formation. This method was developed to determine the individual risk of a patient and to study the subfactors which contribute to the susceptibility. This would also offer the possibility of evaluating the effect of preventive treatment aimed at reducing the susceptibility. The method was found to discriminate between preselected elderly patients at risk on the one hand, and non-risk patients and healthy young adults on the other hand. No differences in blood flow responses were found between the non-risk elderly patients and the healthy young adults. This suggests that age per se is not a factor in the formation of pressure sores. In the risk group the recovery time after pressure relief was found to be three times as long as the duration of the pressure exercise. This indicates that the recovery time after pressure exercise may be as important as the period of pressure exercise in deducing the risk of developing decubitus ulcers.

  12. Stable xenon CT measurement of cerebral blood flow in cardiac transplantation candidates: Correlation with cognitive function

    International Nuclear Information System (INIS)

    Bello, J.A.; Fink, M.E.; Hilal, S.K.; Rose, E.A.; Reemtsma, K.

    1987-01-01

    Thirteen consecutive unselected patients with NYHA class 4 cardiac failure referred for cardiac transplantation underwent neurologic examination and cerebral blood flow measurement (rCBF) using the stable xenon enhanced CT method on a GE9800 system. Eleven men and two women were studied (mean age = 43.8 +- 6.1). On neurological examination, six of the patients demonstrated normal mental function; the remaining seven patients demonstrated memory, language, or learning impairment. There was no difference in mean cardiac output between the groups (4.9 L/min +- 1.68 vs. 4.2L/min +- 1.57). rCBF was significantly reduced in the impaired group. Cognitive impairment in patients with cardiac failure can be correlated with cerebral ischemia. Stable xenon CT measurement of rCBF in transplant candidates may help identify patients requiring more rapid transplantation to prevent permanent cerebral injury

  13. Which markers of subclinical organ damage to measure in individuals with high normal blood pressure?

    DEFF Research Database (Denmark)

    Sehestedt, Thomas; Jeppesen, Jørgen; Hansen, Tine W

    2009-01-01

    plaques or urine albumin/creatinine ratio of at least the 90th percentile did not produce significantly worse results. Seventy-five percent of individuals with three or more traditional risk factors had SOD. CONCLUSION: In healthy individuals with high normal BP, measuring two of pulse wave velocities......OBJECTIVE: Medical treatment of healthy individuals with high normal blood pressure (BP) is recommended if there is subclinical organ damage (SOD). We examined which markers of SOD to use based on their supplementary prognostic value. METHODS: In a population sample of 1968 individuals, aged 41, 51......, 61 and 71 years, without diabetes, prior stroke or myocardial infarction, not receiving any cardiovascular, antidiabetic or lipid-lowering medications, we measured urine albumin/creatinine ratio, carotid atherosclerotic plaques, carotid/femoral pulse wave velocity and left ventricular mass index...

  14. Revalidation of game for teaching blood pressure auscultatory measurement: a pilot study.

    Science.gov (United States)

    Bellan, Margarete Consorti; Alves, Vanessa Cortez; Neves, Mayza Luzia Dos Santos; Lamas, José Luiz Tatagiba

    2017-01-01

    To adapt a pre-existing educational game, making it specific to the teaching of blood pressure auscultatory measurement, and to apply this game in a pilot study. The original game cards were altered by the authors and submitted to content validation by six experts in the field. After redesigns, the game was applied to 30 subjects, who answered a questionnaire (pre-test and post-test) on auscultatory measurement. Data were analyzed descriptively and by the paired Student's t-test and paired Wilcoxon test. Throughout the content validation process, 17 of the 28 original cards were modified. Of these 17 cards, 13 obtained 80% agreement, and the rest were modified according to the judges' suggestions. The obtained grades significantly increased between pre- and the post-test. It was concluded that the reformulated game presented satisfactory evidence of content validity. Its use as a teaching-learning method was effective for this sample.

  15. Role of cerebral blood volume changes in brain specific-gravity measurements

    International Nuclear Information System (INIS)

    Picozzi, P.; Todd, N.V.; Crockard, A.H.

    1985-01-01

    Cerebral blood volume (CBV) was calculated in gerbils from specific-gravity (SG) changes between normal and saline-perfused brains. Furthermore, changes in CBV were investigated during ischemia using carbon-14-labeled dextran (MW 70,000) as an intravascular marker. Both data were used to evaluate the possible error due to a change in CBV on the measurement of ischemic brain edema by the SG method. The methodological error found was 0.0004 for a 100% CBV change. This error is insignificant, being less than the standard deviation in the SG measured for the gerbil cortex. Thus, CBV changes are not responsible for the SG variations observed during the first phase of ischemia. These variations are better explained as an increase of brain water content during ischemia

  16. Anxiety and cerebral blood flow during behavioral challenge. Dissociation of central from peripheral and subjective measures

    International Nuclear Information System (INIS)

    Zohar, J.; Insel, T.R.; Berman, K.F.; Foa, E.B.; Hill, J.L.; Weinberger, D.R.

    1989-01-01

    To investigate the relationship between anxiety and regional cerebral blood flow, we administered behavioral challenges to 10 patients with obsessive-compulsive disorder while measuring regional cerebral blood flow with the xenon 133 inhalation technique. Each patient was studied under three conditions: relaxation, imaginal flooding, and in vivo (actual) exposure to the phobic stimulus. Subjective anxiety, obsessive-compulsive ratings, and autonomic measures (heart rate, blood pressure) increased significantly, but respiratory rate and PCO 2 did not change across the three conditions. Regional cerebral blood flow increased slightly (in the temporal region) during imaginal flooding, but decreased markedly in several cortical regions during in vivo exposure, when anxiety was highest by subjective and peripheral autonomic measures. These results demonstrate that intense anxiety can be associated with decreased rather than increased cortical perfusion and that ostensibly related states of anxiety (eg, anticipatory and obsessional anxiety) may be associated with opposite effects on regional cerebral blood flow

  17. Isotopic method using xenon-133 for assessing placental blood flow and for detecting light-for-dates babies

    Energy Technology Data Exchange (ETDEWEB)

    Wolfson, M R [Cape Town Univ. (South Africa). Dept. of Obstetrics and Gynaecology; Blake, K C.H. [Groote Schuur Hospital, Cape Town (South Africa). Dept. of Bio-Engineering and Medical Physics

    1975-01-25

    A method for measuring uteroplacental blood flow is described and applied to mothers with light-for-dates and normally-grown fetuses. The two groups of fetuses showed a significant difference in their clearance rates, the importance of which is discussed in terms of diagnosis and management. (INIS)

  18. Measurement of blood pressure, ankle blood pressure and calculation of ankle brachial index in general practice

    DEFF Research Database (Denmark)

    Nexøe, Jørgen; Damsbo, Bent; Lund, Jens Otto

    2012-01-01

    BACKGROUND: Low ankle brachial index (ABI) is a sensitive measure of 'burden' of atherosclerosis, indicating cardiovascular risk of the asymptomatic patient. Conventionally, ABI values......BACKGROUND: Low ankle brachial index (ABI) is a sensitive measure of 'burden' of atherosclerosis, indicating cardiovascular risk of the asymptomatic patient. Conventionally, ABI values...

  19. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  20. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index.

    Science.gov (United States)

    Wittke, Estefânia; Fuchs, Sandra C; Fuchs, Flávio D; Moreira, Leila B; Ferlin, Elton; Cichelero, Fábio T; Moreira, Carolina M; Neyeloff, Jeruza; Moreira, Marina B; Gus, Miguel

    2010-11-05

    Blood pressure (BP) variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM). We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI). In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time), standard deviation (SD) of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40) was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007). In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04). In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P < 0.01). None of the other indexes of BP variability were associated with ABI in univariate and multivariate analyses. Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  1. Nurse-measured or ambulatory blood pressure in routine hypertension care

    NARCIS (Netherlands)

    Veerman, D. P.; van Montfrans, G. A.

    1993-01-01

    Nurses are considered to evoke less white-coat hypertension, and might therefore be able to estimate average blood pressure as well as and more conveniently than ambulatory monitoring. The objective of the present study was to determine the correspondence between blood pressure measured by a doctor

  2. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...

  3. Student Nurses' Knowledge in Relation to Blood Pressure Measurement by Sphygmomanometry and Auscultation.

    Science.gov (United States)

    Torrance, Colin; Serginson, Eve

    1996-01-01

    British nursing students (78 of 93) completed a questionnaire about blood pressure; 90% were not familiar with Korotkoff sounds or auscultary gap; most thought blood pressure was the same in both arms; 63% knew resting was essential before measurement; 59% assessed the arm for cuff size; only 25% thought the cuff should be placed at heart level.…

  4. Cerebral blood volume measurement using radioactive carboxyhemoglobin and positron emission tomography. Chapter 26

    International Nuclear Information System (INIS)

    Kanno, Iwao; Murakami, Matsutaro; Miura, Shuichi; Iida, Hidehiro; Takahashi, Kazuhiro; Sasaki, Hiroshi; Uemura, Kazuo

    1988-01-01

    This paper aims to describe the technical basis for this simplest cerebral blood volume (CBV) measurement using CO-labelled red blood cells and PET and to clarify the error sources in the technique which will become critical when we perform studies on physiological activation of CBV. 17 refs.; 6 figs.; 2 tabs

  5. Modelling blood safety

    NARCIS (Netherlands)

    Janssen, M.P.

    2010-01-01

    This thesis describes the development and application of methods and models to support decision making on safety measures aimed at preventing the transmission of infections by blood donors. Safety measures refer to screening tests for blood donors, quarantine periods for blood plasma, or methods for

  6. The EDAPA Project (Education of self-measurement of blood pressure in Grottaglie

    Directory of Open Access Journals (Sweden)

    S. Lenti

    2013-05-01

    Full Text Available AIM OF THE STUDY The EDAPA Project (Education of self-measurement of blood pressure was conceived to train hypertensive patients in self blood pressure monitoring (SBPM and to survey their feedback, including patient’ assessment, by recording their related cardiovascular diseases (CVD risks factors and lifestyle habits. METHODS The project was conducted during the year 2006. Initially we met Grottaglie’s citizens and illustrated to participants the importance of SBPM at home in the overall management of hypertension, that might lead to a better control of BP and cardiovascular outcomes. After explaining the correct technique for SBPM, we distributed semiautomatic devices (OMRON M6 and asked the participants to fill in the Hypertension Questionnaire Form and to record their own blood pressure values in a diary. RESULTS Among almost 3,000 citizens interviewed, 370 (198 M, 172 F; mean age: 60 years agreed to take part in our study. They were hypertensive for almost 10 years, but waited 3 years before beginning therapy. They measured BP 4 times a month and, in the same sitting, 66% of them carried out only 1 measurement, 29% of them 2 measurements and only 2.5% carried out 3 measurements. Taking as reference BP value of 135/85 mmHg, we registered 28% of the population as normotensive and the remaining 72% as hypertensive. Among the hypertensives, 30% showed a good control, 55% showed a bad one and the remaining 15% was not aware of being hypertensive. Adding non-treated hypertensives to those treated but not controlled, we noticed that 70% of the participants was not properly controlled. Regarding risk factors, almost 64% showed hypercholesterolemia; 18% were smokers; 35% of males and 28% of females showed hyperglicemia and 63% of the latter had a waist line > 88 cm; 32% used to consume alcohol (46% males and 15% females; 26% had a metabolic syndrome; 13% was affected by vascular brain injuries, 30% by peripheral artheriopaty, 35% had heart

  7. Performance of an app measuring spot quality in dried blood spot sampling

    NARCIS (Netherlands)

    Veenhof, Herman

    2016-01-01

    Introduction: The Dried Blood Spot sampling (DBS) method gives patients and health care workers the opportunity for remote sampling using a dro