WorldWideScience

Sample records for blood measurement method

  1. Validation of a laboratory method of measuring postpartum blood loss.

    Science.gov (United States)

    Chua, S; Ho, L M; Vanaja, K; Nordstrom, L; Roy, A C; Arulkumaran, S

    1998-01-01

    Laboratory methods give more accurate measurement of blood loss in the postpartum period than visual estimation. In order to evaluate a laboratory method used to quantify blood loss postpartum, blood lost at gynecological operations was collected in a measuring bottle. The measured amount of blood (50-1,000 ml) was then poured onto absorbent paper towels and sanitary pads, in order to mimic conditions when measuring blood loss in clinical trials in the postpartum period. The amount of blood absorbed onto the absorbent paper and sanitary pads was measured by a rapid method of automatic extraction and photometric measurement of alkaline hematin. The study shows that the method provides a reliable and accurate means of measuring blood loss. The error in each case was less than 10% with an intraclass correlation coefficient of almost 1.

  2. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  3. Simple Radiowave-Based Method for Measuring Peripheral Blood Flow

    Data.gov (United States)

    National Aeronautics and Space Administration — Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery...

  4. Noninvasive 133Xe inhalation method for cerebral blood flow measurement

    International Nuclear Information System (INIS)

    Takagi, Shigeharu; Kobatake, Keitaro; Shinohara, Yukito

    1991-01-01

    Recent development of the 133 Xe inhalation technique has made it possible to measure cerebral blood flow (CBF) noninvasively. Recording of the head curves from the frontal and temporal areas during inhalation of 133 Xe, however, is contaminated by the artifact from the air passages. A method based on Fourier transforms was reported to be able to eliminate air passage artifact (APA) effectively. However, it was pointed out that such an algorithm does not give a complete correction if the artifact seen by the head detectors differs in shape from that recorded from the airways at the mouth, which may happen when there is a slow isotope convection in the nasal and sinus cavities. The purpose of this study was to compare the CBF values calculated by the Fourier method with those by the conventional method of Obrist (VM method). Mean hemispheric gray matter flow (F 1 ) calculated by the VM method in 11 subjects, including normal volunteers and patients with various neurological diseases, was 69.2±13.2 mg/100 g brain/ min, whereas F 1 calculated by the Fourier method in the same subjects was 64.4±13.5, indicating that APA can be effectively eliminated by the Fourier method. The F 1 values calculated by the Fourier method from the frontal and temporal regions were relatively high, and closer to the F 1 values calculated by the VM method. The size of the APA was large in these regions. It was concluded that the deformed APA contaminated the results in these regions, and could not be eliminated effectively by the Fourier method. It is suggested that the shape of the head curve and the size of APA should be carefully examined to ensure that CBF data are reliable. (author)

  5. Methods for measurement of cerebral blood flow in man

    DEFF Research Database (Denmark)

    Lassen, N A

    1976-01-01

    -cerebral uptake, and insensitive both for detecting regional ischemia and regional hyperemia. The spatial resolution is also much more limited. For these reasons great caution must be exercised in interpreting the results. Methods yielding three-dimensional rCBF data will be needed in order to gain more precise...... information both on spatial localization and, especially, on ischemic areas. The most promising is computer-assisted axial tomography with freely diffusible radioactive isotopes or with x-rays using an intra-arterial injection of contrast. But, the available techniques are still too slow: in order to measure...

  6. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    Science.gov (United States)

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  7. Development of a fluorescent method for simultaneous measurement of glucose concentrations in interstitial fluid and blood

    International Nuclear Information System (INIS)

    Shi, Ting; Li, Dachao; Li, Guoqing; Xu, Kexin; Chen, Limin; Lin, Yuan; Lu, Luo

    2013-01-01

    Continuous blood glucose monitoring is of great clinical significance to patients with diabetes. One of the effective methods to monitor blood glucose is to measure glucose concentrations of interstitial fluid (ISF). However, a time-delay problem exists between ISF and blood glucose concentrations, which results in difficulty in indicating real-time blood glucose concentrations. Therefore, we developed a fluorescent method to verify the accuracy and reliability of simultaneous ISF and blood glucose measurement, especially incorporating it into research on the delay relationship between blood and ISF glucose changes. This method is based on a competitive reaction among borate polymer, alizarin and glucose. When glucose molecules combine with borate polymers in alizarin–borate polymer competitively, changes in fluorescence intensity demonstrate changes in glucose concentrations. By applying the measured results to the blood and ISF glucose delay relationship, we were able to calculate the time delay as an average of 2.16 ± 2.05 min for ISF glucose changes with reference to blood glucose concentrations. (paper)

  8. Comparison of three methods of sampling trout blood for measurements of hematocrit

    Science.gov (United States)

    Steucke, Erwin W.; Schoettger, Richard A.

    1967-01-01

    Trout blood is frequently collected for hematocrit measurements by excising the caudal fin (Snieszko, 1960), but this technique is impractical if valuable fish are to be sampled or if repeated observations are desired. Schiffman (1959) and Snieszko (1960) collected blood from the dorsal aorta and the heart, but these methods are relatively slow and require the preparation of needles and syringes. The use of pointed capillary tubes for cardiac punctures increases the speed of sampling, but body fluids may dilute the blood (Perkins, 1957; Larsen and Snieszko, 1961; and Normandau, 1962). There is need for methods of sampling which are rapid and which neither influence hematological determinations nor harm the fish.

  9. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    International Nuclear Information System (INIS)

    McCarthy, B M; O'Flynn, B; Mathewson, A

    2011-01-01

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  10. An Investigation of Pulse Transit Time as a Non-Invasive Blood Pressure Measurement Method

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, B M; O' Flynn, B; Mathewson, A, E-mail: brian.mccarthy@tyndall.ie [Tyndall National Institute, UCC, Lee Maltings, Prospect Row, Cork (Ireland)

    2011-08-17

    The objective of this paper is to examine the Pulse Transit Method (PTT) as a non-invasive means to track Blood Pressure over a short period of time. PTT was measured as the time it takes for an ECG R-wave to propagate to the finger, where it is detected by a photoplethysmograph sensor. The PTT method is ideal for continuous 24-hour Blood Pressure Measurement (BPM) since it is both cuff-less and non-invasive and therefore comfortable and unobtrusive for the patient. Other techniques, such as the oscillometric method, have shown to be accurate and reliable but require a cuff for operation, making them unsuitable for long term monitoring. Although a relatively new technique, the PTT method has shown to be able to accurately track blood pressure changes over short periods of time, after which re-calibration is necessary. The purpose of this study is to determine the accuracy of the method.

  11. Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations.

    Science.gov (United States)

    Kang, Yang Jun

    2017-09-06

    Red blood cell (RBC) aggregation and erythrocyte sedimentation rate (ESR) are considered to be promising biomarkers for effectively monitoring blood rheology at extremely low shear rates. In this study, a microfluidic-based measurement technique is suggested to evaluate RBC aggregation under hematocrit variations due to the continuous ESR. After the pipette tip is tightly fitted into an inlet port, a disposable suction pump is connected to the outlet port through a polyethylene tube. After dropping blood (approximately 0.2 mL) into the pipette tip, the blood flow can be started and stopped by periodically operating a pinch valve. To evaluate variations in RBC aggregation due to the continuous ESR, an EAI (Erythrocyte-sedimentation-rate Aggregation Index) is newly suggested, which uses temporal variations of image intensity. To demonstrate the proposed method, the dynamic characterization of the disposable suction pump is first quantitatively measured by varying the hematocrit levels and cavity volume of the suction pump. Next, variations in RBC aggregation and ESR are quantified by varying the hematocrit levels. The conventional aggregation index (AI) is maintained constant, unrelated to the hematocrit values. However, the EAI significantly decreased with respect to the hematocrit values. Thus, the EAI is more effective than the AI for monitoring variations in RBC aggregation due to the ESR. Lastly, the proposed method is employed to detect aggregated blood and thermally-induced blood. The EAI gradually increased as the concentration of a dextran solution increased. In addition, the EAI significantly decreased for thermally-induced blood. From this experimental demonstration, the proposed method is able to effectively measure variations in RBC aggregation due to continuous hematocrit variations, especially by quantifying the EAI.

  12. Microfluidic-Based Measurement Method of Red Blood Cell Aggregation under Hematocrit Variations

    Science.gov (United States)

    2017-01-01

    Red blood cell (RBC) aggregation and erythrocyte sedimentation rate (ESR) are considered to be promising biomarkers for effectively monitoring blood rheology at extremely low shear rates. In this study, a microfluidic-based measurement technique is suggested to evaluate RBC aggregation under hematocrit variations due to the continuous ESR. After the pipette tip is tightly fitted into an inlet port, a disposable suction pump is connected to the outlet port through a polyethylene tube. After dropping blood (approximately 0.2 mL) into the pipette tip, the blood flow can be started and stopped by periodically operating a pinch valve. To evaluate variations in RBC aggregation due to the continuous ESR, an EAI (Erythrocyte-sedimentation-rate Aggregation Index) is newly suggested, which uses temporal variations of image intensity. To demonstrate the proposed method, the dynamic characterization of the disposable suction pump is first quantitatively measured by varying the hematocrit levels and cavity volume of the suction pump. Next, variations in RBC aggregation and ESR are quantified by varying the hematocrit levels. The conventional aggregation index (AI) is maintained constant, unrelated to the hematocrit values. However, the EAI significantly decreased with respect to the hematocrit values. Thus, the EAI is more effective than the AI for monitoring variations in RBC aggregation due to the ESR. Lastly, the proposed method is employed to detect aggregated blood and thermally-induced blood. The EAI gradually increased as the concentration of a dextran solution increased. In addition, the EAI significantly decreased for thermally-induced blood. From this experimental demonstration, the proposed method is able to effectively measure variations in RBC aggregation due to continuous hematocrit variations, especially by quantifying the EAI. PMID:28878199

  13. Evaluation of three methods for hemoglobin measurement in a blood donor setting

    Directory of Open Access Journals (Sweden)

    Jacob Rosenblit

    1999-05-01

    Full Text Available CONTEXT: The hemoglobin (Hb level is the most-used parameter for screening blood donors for the presence of anemia, one of the most-used methods for measuring Hb levels is based on photometric detection of cyanmetahemoglobin, as an alternative to this technology, HemoCue has developed a photometric method based on the determination of azide metahemoglobin. OBJECTIVE: To evaluate the performance of three methods for hemoglobin (Hb determination in a blood bank setting. DESIGN: Prospective study utilizing blood samples to compare methods for Hb determination. SETTING: Hemotherapy Service of the Hospital Israelita Albert Einstein, a private institution in the tertiary health care system. SAMPLE: Serial blood samples were collected from 259 individuals during the period from March to June 1996. MAIN MEASUREMENTS: Test performances and their comparisons were assessed by the analysis of coefficients of variation (CV, linear regression and mean differences. RESULTS: The CV for the three methods were: Coulter 0.68%, Cobas 0.82% and HemoCue 0.69%. There was no difference between the mean Hb determination for the three methods (p>0.05. The Coulter and Cobas methods showed the best agreement and the HemoCue method gave a lower Hb determination when compared to both the Coulter and Cobas methods. However, pairs of methods involving the HemoCue seem to have narrower limits of agreement (± 0.78 and ± 1.02 than the Coulter and Cobas combination (± 1.13. CONCLUSION: The three methods provide good agreement for hemoglobin determination.

  14. Microsampling Collection Methods for Measurement of C-peptide in Whole Blood.

    Science.gov (United States)

    Jones, Charlotte; Dunseath, Gareth J; Lemon, Jessica; Luzio, Stephen D

    2018-03-01

    Microsampling techniques are alternative methods to venous sampling for obtaining blood for measurement of circulating biomarkers, offering the convenience of reduced sample volume and elimination of the need for phlebotomists. Dried blood spot (DBS) microsampling methods have been used for many years while more recently a volumetric absorptive microsampling device (VAMS™) has been introduced. In diabetes mellitus, circulating C-peptide is commonly used as an indicator of endogenous insulin secretion and clinical measurement can aid in diagnosis as well as informing on therapy. This pilot study investigated the effectiveness of microsampling collection of capillary blood for measurement of C-peptide. Capillary blood was collected into capillary tubes and centrifuged for plasma samples. Simultaneous samples were also collected using both microsampling methods (DBS and VAMS). Blood from both microsamplers was extracted prior to assaying for C-peptide alongside the corresponding plasma samples, using specific immunoassays and results obtained from microsampling compared to the reference plasma concentrations. Stability was determined by collecting duplicate DBS and VAMS and assaying both in a single assay after storing one at -20°C immediately and one at room temperature for 48 hours post-collection. Good agreement was observed between C-peptide concentrations in plasma and equivalent DBS and VAMS samples ( R 2 = .929 and .9231, DBS and VAMS, respectively), with mean differences of 75.7 and 8.4 pmol/L observed for DBS and VAMS. Small decreases in C-peptide of 11.6% and 0.1% were observed after 48 hours storage for DBS and VAMS, respectively. C-peptide collected using DBS and VAMS showed good agreement with reference plasma concentrations, suggesting both would be an effective microsampling method for collection and measurement of C-peptide.

  15. Quantitative measurement of blood circulation in tests of rats using nuclear medical methods

    International Nuclear Information System (INIS)

    Ripke, R.

    1980-01-01

    The experiments show that is it is possible to quantitatively assess the blood circulation and, within limits, the germinative function of tests by measuring the impulses of an incorporated radionuclide (99-Tc-pertechnetate) using an uptake measuring instrument. This is a rapid and unbloody method to be adopted in human medicine. 'Acute tests' or pre-damaged tests can thus be exactly diagnosed. In the former case the circulation modification and in the latter the evaluation of the germinative function ability is of main interest. The most important measuring criterion is the 15-minute-uptake U; it represents the blood circulation in the tests measured. The germinative function ability is evaluated on the basis of the accumulation activity Nsub(max). (orig./MG) [de

  16. Evaluation of the Efficacy and Correlation between Blood Glucose Measured Using Glucometers and Enzymatic Laboratory Methods

    Directory of Open Access Journals (Sweden)

    R Rasouli

    2012-05-01

    Full Text Available

    Background and Objectives: Diabetes Mellitus (DM is the most common chronic metabolic disease, with many complications including renal failure, blindness and non-traumatic amputation, so it is important to monitor and regulate blood glucose. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection of blood glucose compared with standard laboratory methods.

     

    Methods: In this analytical study, we compared the capillary blood glucose levels of 60 volunteers with mean age of 32.8±9.6 years in Tabriz Mehr Laboratory as determined by test strips (two different Glucometers with venous blood glucose levels’ measurements by the enzymatic method (the standard laboratory kit. Data were analyzed using one way-ANOVA test, T-test, Pearson correlation and Bland and Altman plot.

     

    Results: The mean differences of No: 1 and No: 2 Glucometers with enzymatic laboratory method were 20.78±11.61 and 4.5±3.76mg/dl respectively. The one way ANOVA test indicated significant differences between three methods (p<0.05. Further Duncan's test revealed significant differences between two devices (p=0.001 and device No.1 and laboratory method (p=0.001; however, the differences between device No.2 and laboratory method were not statistically significant (p=0.83.

     

    Conclusion: According to the results, calibrating the devices with laboratory instruments in order to make major clinical decisions is recommended.

  17. Comparative study of methods for blood flow measurement within transverse sinuses by using MR

    International Nuclear Information System (INIS)

    Gao Gejun; Feng Xiaoyuan; Yang Bojie; Geng Daoying

    2003-01-01

    Objective: To assess the accuracy of two-dimensional phase contrast (2D-PC) MR method for blood flow measurement within transverse sinuses by comparing this method with cine phase contrast (cine-PC) MR and Doppler in volunteers and patients. Methods: (1) A total of 12 transverse sinuses were examined in 8 healthy volunteers. 2D-PC MR and cine-PC MR were used respectively to measure the transverse area of flow, the flow velocities, and the volumetric flow rates in the same position in every transverse sinus. Paired t-test was used for comparison between the results determined by 2D-PC MR and that determined by cine-PC MR. (2) A total of 6 transverse sinuses were examined in 5 patients who needed operation. 2D-PC MR was used to determine the blood flow velocity of transverse sinus before operation, and Doppler was used to determine the blood flow velocity of the same transverse sinus during operation. The linear regression analysis was used for statistical analysis. Results: (1) Statistical analysis indicated that there were no significant difference among the transverse area of flow (t = -1.106, P = 0.293), the flow velocities (t = 0.262, P = 0.798), and the volumetric flow rates (t = 0.439, P = 0.669) measured by using 2D-PC MR and cine PC MR, respectively. (2) The correlation between flow velocities determined by 2D-PC MR imaging before operation and that determined by Doppler during operation was in excellent agreement (Y-circumflex = 1.303 x + 0.62, r 2 = 0.88). Conclusion: 2D-PC MR may be a practical convenient method for blood flow measurement within transverse sinuses system

  18. Method of measuring blood oxygenation based on spectroscopy of diffusely scattered light

    Science.gov (United States)

    Kleshnin, M. S.; Orlova, A. G.; Kirillin, M. Yu.; Golubyatnikov, G. Yu.; Turchin, I. V.

    2017-05-01

    A new approach to the measurement of blood oxygenation is developed and implemented, based on an original two-step algorithm reconstructing the relative concentration of biological chromophores (haemoglobin, water, lipids) from the measured spectra of diffusely scattered light at different distances from the radiation source. The numerical experiments and approbation of the proposed approach using a biological phantom have shown the high accuracy of the reconstruction of optical properties of the object in question, as well as the possibility of correct calculation of the haemoglobin oxygenation in the presence of additive noises without calibration of the measuring device. The results of the experimental studies in animals agree with the previously published results obtained by other research groups and demonstrate the possibility of applying the developed method to the monitoring of blood oxygenation in tumour tissues.

  19. 133-xenon intravenous injection method for regional cerebral blood flow measurements

    International Nuclear Information System (INIS)

    Shinohara, Yukito; Takagi, Shigeharu; Kobatake, Keitaro

    1984-01-01

    The non-invasive 133-Xenon intravenous (IV) injection method for measuring regional cerebral blood flow (rCBF) has many advantages compared to the 133-Xenon inhalation method. In order to evaluate the possibility of clinical application of this IV injection method, normal regional and mean hemispheric values of rCBF were determined in this study. The rCBF data were obtained on 27 normal Japanese right-handed volunteers with an age range of 18 to 81 years (mean age 43). The subjects were requested to relax, keeping the eyes closed but without falling asleep. End-tidal 133-Xenon curves were used for correction of recirculation. The blood flow of the fast compartment (gray matter) of the brain was calculated, as well as the initial slope index (ISI) and the relative weight and the fractional flow of the fast compartment. CBF values thus obtained were compared to those obtained by the 133-Xenon inhalation method previously reported by us. The mean gray matter flow values for the right hemisphere was 90.3 +- 17.5 ml/100 g brain/min (mean +- S.D.) and that for the left was 90.0 +- 17.8. The mean value of ISI for the right hemisphere was 75.1 +- 17.0 and that for the left was 74.6 +- 17.0. There was no significant difference of blood flow between the hemispheres. These values were higher than those obtained by the inhalation method. The reason for this difference is discussed. The rCBF values were the highest frontally and the lowest parietooccipitally in both hemispheres, which is in good agreement with the results obtained by the other non-invasive methods and the intracarotid injection method. It is concluded that the 133-Xenon intravenous injection method, which has many advantages compared with the inhalation method, is applicable for rCBF measurements in man. (author)

  20. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  1. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    :Ag) or estimated with an amidolytic method (FVII:Am). We have investigated whether FVII:Am is a valuable alternative to FVII:Ag. FVII:Ag and FVII:Am were measured in 147 plasma samples from blood donors, patients on oral anticoagulant therapy, postmenopausal women on hormone replacement therapy, in postprandial...... omitting the data from patients on oral anticoagulant therapy, with mean values of 113 U/ml for FVII:Ag and 110 U/ml for FVII:Am (p regression analysis, the intercept (alpha=-21.50) was different from zero (p

  2. Cerebral blood flow measurement using 123I-IMP graph plot method with SPECT. Comparison with autoradiography method

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kamitani, Hideki; Ishibashi, Minako; Ito, Satoru; Ogawa, Toshihide

    2011-01-01

    The purpose of this study was to evaluate quantification of cerebral blood flow (CBF) values using 123 I-iodoamphetamine (IMP) graph plot (GP) method with single photon emission computed tomography (SPECT), compared with autoradiography (ARG) method. IMP-SPECT by GP combined with ARG method at rest was performed in 40 patients to determine the equation of linear regression for GP method in our institution. In addition, we compared regional CBF (rCBF) values at rest between GP and ARG methods in 10 other patients. Among all 50 patients, acetazolamide (ACZ)-challenged SPECT by GP combined with ARG method using 2-day protocol was performed in 10 patients. We also compared the rCBF values after ACZ challenge between GP and ARG methods in these 10 patients. The equation of linear regression for GP method in our institution was y=1.945x+20.36 (R 2 =0.586, P 2 =0.624, P 2 =0.150, P<0.001). IMP-SPECT by GP method at rest is useful to measure reliable rCBF values without arterial blood sampling, although we need pay attention to interpret the result of 2-day protocol ACZ-challenged SPECT by GP method. (author)

  3. [Blood pressure measurement by primary care physicians: comparison with the standard method].

    Science.gov (United States)

    Asai, Y; Kawamoto, R; Nago, N; Kajii, E

    2000-04-01

    To examine the usual methods of blood pressure (BP) measurement by primary care physicians and to compare them with the standard methods. Cross-sectional survey by self-administered questionnaire. Primary care physicians who graduated from Jichi Medical School and were working at clinics. Each standard method for 20 items was defined as the one that was most frequently recommended by 6 guidelines (USA 3, UK 1, Canada 1, Japan 1) and a recent comprehensive review about BP measurement. Of 333 physicians, 190 (58%) responded (median age 33, range 26 to 45 years). Standard methods and percentages of physicians who follow them are: [BP measurement, 17 items] supported arm 96%; measurement to 2 mmHg 91%; sitting position 86%; mercury sphygmomanometer 83%; waiting > or = 1 minute between readings 58%; palpation to assess systolic BP before auscultation 57%; check accuracy of home BP monitor 56%; Korotkoff Phase V for diastolic BP 51%; bilateral measurements on initial visit 44%; small cuff available 41%; > or = 2 readings in patients with atrial fibrillation 38%; > or = 2 readings on one visit 20%; cuff deflation rate of 2 mmHg/pulse 14%; large cuff available 13%; check accuracy of monitor used for home visit 8%; waiting time > or = 5 minute 3%; readings from the arm with the higher BP 1%. [Knowledge about BP monitor, 2 items] appropriate size bladder: length 11%; width 11%. [Check of sphygmomanometer for leakage, inflate to 200 mmHg then close valve for 1 minute] leakage < 2 mmHg 6%; median 10 (range 0-200) mmHg. Average percentage of all 20 items was 39%. Number of methods physicians follow as standard: median 8 (range 4 to 15) and this number did not correlate with any background characteristics of the physicians. Furthermore, we also obtained information on methods not compared with the standard. Fifty-four percentage of physicians used more standard methods in deciding the start or change of treatment than in measuring BP of patients with good control. About 80% of

  4. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  5. Noninvasive quantitative measurement of cerebral blood flow with [sup 123]I-IMP; Lung monitoring method

    Energy Technology Data Exchange (ETDEWEB)

    Oguchi, Kazuhiro; Kasuga, Toshio; Sone, Shusuke; Nakanishi, Fumiko; Ito, Atsuko (Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine); Tanizaki, Yoshio

    1993-06-01

    In order to perform a less invasive determination of regional cerebral blood flow (rCBF) using N-isopropyl-p-[[sup 123]I] iodoamphetamine (I-123-IMP), we used the lung clearance curve as a substitute for the arterial blood activity curve as an input function. We assumed that a major portion of the intravenously injected I-123-IMP initially accumulates in the lung and then is gradually cleared from the lung pool to enter the systemic circulation. In this case lung clearance could be considered nearly equal to the integral of arterial blood activity shown during the examination. We used a single probe detector to obtain the lung clearance curve as the difference between sequential lung activity and peak lung activity. The absolute value of the sequential change in arterial blood activity was estimated from the differentiated lung clearance curve compared with the arterial blood activity that was estimated by actual blood sampling once during the examination. The rCBF was calculated by the thus estimated arterial blood activity curve and brain activity by SPECT image using the microsphere model. The values of rCBF obtained by this method were similar to those obtained by the continuous arterial sampling method, and this lung monitoring method was thought to be applicable to clinical use. (author).

  6. Validation of a new non-invasive blood pressure measurement method on mice via pulse wave propagation time measurement on a cuff

    OpenAIRE

    Nguyen, Xuan P.; Kronemayer, Ralf; Herrmann, Peter; Mejía, Atila; Daw, Zamira; Nguyen, Xuan D.; Kränzlin, Bettina; Gretz, Norbert

    2011-01-01

    In the present article, we describe the validation of a new non-invasive method for measuring blood pressure (BP) which also enables to determine the three BP values: systolic, diastolic and mean value. Our method is based on the pulse transit time (PTT) measurement along an artery directly at the BP cuff. The accuracy of this method was evaluated by comparison with the direct simultaneous measurement of blood pressure from 40 anesthetized female mice. Close correlation ...

  7. A preliminary verification of the floating reference measurement method for non-invasive blood glucose sensing

    Science.gov (United States)

    Min, Xiaolin; Liu, Rong; Fu, Bo; Xu, Kexin

    2017-06-01

    In the non-invasive sensing of blood glucose by near-infrared diffuse reflectance spectroscopy, the spectrum is highly susceptible to the unstable and complicated background variations from the human body and the environment. In in vitro analyses, background variations are usually corrected by the spectrum of a standard reference sample that has similar optical properties to the analyte of interest. However, it is hard to find a standard sample for the in vivo measurement. Therefore, the floating reference measurement method is proposed to enable relative measurements in vivo, where the spectra under some special source-detector distance, defined as the floating reference position, are insensitive to the changes in glucose concentration due to the absorption effect and scattering effect. Because the diffuse reflectance signals at the floating reference positions only reflect the information on background variations during the measurement, they can be used as the internal reference. In this paper, the theoretical basis of the floating reference positions in a semi-infinite turbid medium was discussed based on the steady-state diffusion equation and its analytical solutions in a semi-infinite turbid medium (under the extrapolated boundary conditions). Then, Monte-Carlo (MC) simulations and in vitro experiments based on a custom-built continuous-moving spatially resolving double-fiber NIR measurement system, configured with two types of light source, a super luminescent diode (SLD) and a super-continuum laser, were carried out to verify the existence of the floating reference position in 5%, 10% and 20% Intralipid solutions. The results showed that the simulation values of the floating reference positions are close to the theoretical results, with a maximum deviation of approximately 0.3 mm in 1100-1320 nm. Great differences can be observed in 1340-1400 nm because the optical properties of Intralipid in this region don not satisfy the conditions of the steady

  8. Investigation of electrolyte measurement in diluted whole blood using spectroscopic and chemometric methods

    Science.gov (United States)

    Soller, Babs R.; Favreau, Janice; Idwasi, Patrick O.

    2003-01-01

    The feasibility of using near-infrared (NIR) spectroscopy in combination with partial least-squares (PLS) regression was explored to measure electrolyte concentration in whole blood samples. Spectra were collected from diluted blood samples containing randomized, clinically relevant concentrations of Na+, K+, and Ca2+. Sodium was also studied in lysed blood. Reference measurements were made from the same samples using a standard clinical chemistry instrument. Partial least squares (PLS) was used to develop calibration models for each ion with acceptable results (Na+, R2 = 0.86, CVSEP = 9.5 mmol/L; K+, R2 = 0.54, CVSEP = 1.4 mmol/L; Ca2+, R2 = 0.56, CVSEP = 0.18 mmol/L). Slightly improved results were obtained using a narrower wavelength region (470-925 nm) where hemoglobin, but not water, absorbed indicating that ionic interaction with hemoglobin is as effective as water in causing measurable spectral variation. Good models were also achieved for sodium in lysed blood, illustrating that cell swelling, which is correlated with sodium concentration, is not required for calibration model development.

  9. Measurement of peripheral blood flow in patients with peripheral artery disease: Methods and considerations.

    Science.gov (United States)

    Salisbury, Dereck L; Brown, Rebecca Jl; Bronas, Ulf G; Kirk, Laura N; Treat-Jacobson, Diane

    2018-02-01

    Peripheral artery disease (PAD) is a manifestation of generalized atherosclerosis which results in hemodynamic compromise of oxygen and substrate delivery to the lower extremity skeletal muscles. Hemodynamic assessments are vital in PAD diagnosis and in the evaluation of strategies aimed at treating claudication (i.e. exercise training, revascularization, and pharmacological agents). Venous occlusion plethysmography (VOP) is a century-old, non-invasive technique used to quantify limb blood flow and has been used to evaluate hemodynamic compromise in patients with PAD. However, the literature suggests a wide array of methodological variability in the measurement and analysis of limb blood flow using VOP. In this manuscript, we overview the clinical application of VOP measurement, and secondly we review the methodological variation that occurs during the measurement and analysis of VOP in healthy individuals and in patients with claudication.

  10. Blood pressure measurement in children: which method? which is the gold standard.

    Science.gov (United States)

    Vidal, Enrico; Murer, Luisa; Matteucci, Maria Chiara

    2013-01-01

    The burden of hypertension has become increasingly prevalent in children. Hypertension that begins in childhood can carry on into adulthood, therefore early detection, accurate diagnosis and effective therapy of high blood pressure may improve long-term outcomes of children and adolescents. As far as pediatric hypertension is concerned, doubts still persist about the right instruments, modalities and standards of reference that should be used in routine practice. Due to the dynamic process of growth and development, many physiological parameters undergo intensive change with age. Therefore, in children, the definition of hypertension can not rely on a single blood pressure level but should be based on age- and height-specific percentiles. In this review, we introduce the nephrologist to the correct definition of high blood pressure in children. Moreover, we specifically address the main characteristics of different modalities for blood pressure measurement in children, focusing on practical aspects. The latest international guidelines and appropriate standards of reference for office, ambulatory and home blood pressure data collection are presented. As clinicians are being faced with a greater number of children with hypertension, they should be aware of these peculiarities.

  11. A simple and efficient method for measuring the uptake of radiolabelled compounds by leukocytes in whole blood

    International Nuclear Information System (INIS)

    Pauly, J.L.; Schuller, M.G.; Germain, M.J.

    1977-01-01

    A liquid scintillation counting procedure is described for measuring the uptake of radiolabelled compounds by leukocytes in large or small volumes of whole blood. Color and chemical quenching as well as other technical difficulties noted previously by investigators attempting to process whole blood were eliminated by selectively disrupting the erythrocytes. This was readily accomplished by washing the blood with 3% acetic acid. After bleaching the leukocyte pellet with hydrogen peroxide, the sample was prepared for counting using methods in which the cells were dissolved or oxidized. Examples demonstrating the utility of the proposed technique are presented in which DNA, RNA and protein synthesis of leukocytes from patients with uncontrolled leukemia were measured by the uptake of tritiated thymidine, uridine and leucine, respectively. Also noted is the feasibility of employing a multiple automated sample harvester and whole blood microcultures. The advantages realised by these methods and their potential clinical and experimental utility are discussed. (author)

  12. An effective method for skin blood flow measurement using local heat combined with electrical stimulation.

    Science.gov (United States)

    Almalty, A-M R; Petrofsky, J S; Al-Naami, B; Al-Nabulsi, J

    2009-01-01

    Electrical stimulation (ES) is a modality used to increase skin blood flow (SBF) and to aid in wound healing. A greater SBF in non wounded skin is induced if ES is used in a warm environment compared to a thermoneutral environment, where ES is usually applied. Therefore, in this paper, a method to investigate the effect of local heating and ES on the SBF is developed. A total of 33 males (18-40 years) were divided into group G (n = 15) who received the ES during a global heating protocol and group L (n = 18) who received ES during a local heating protocol. In the global heating protocol, ES (30 Hz, 250 micros) was applied for 15 min on the subject's thigh in thermoneutral (25 +/- 0.5 degrees C) and warm (35 +/- 0.5 degrees C) environments. In the local heating protocol, ES was applied for 15 minutes at 25 degrees C, 35 degrees C and 40 degrees C local skin temperatures. A laser Doppler imager measured the SBF in both protocols pre, during, and post ES. The results of the experiment showed the significant differences in the SBFs were found at pre, during, and post ES in a thermoneutral environment or when the skin was locally cooled to 25 degrees C. The SBFs were significantly increased during and post ES after global heating or during local heating at 35 degrees C and 40 degrees C. There were no significant differences in SBFs between the warm environment and at 35 degrees C of local heating. However, the SBF response to ES was the highest at 40 degrees C of local heating. Thus, ES during local heating of the skin, as well as during global heating is an effective method to increase SBF.

  13. Regional cerebral blood flow measurements by a noninvasive microsphere method using {sup 123}I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi [National Center Hospital for Mental, Nervous, and Muscular Disorders, NCNP, Kodaira, Tokyo (Japan); Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-04-01

    A noninvasive microsphere method using N-isopropyl-p-({sup 123}I)iodoamphetamine ({sup 123}I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  14. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi; Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-01-01

    A noninvasive microsphere method using N-isopropyl-p-( 123 I)iodoamphetamine ( 123 I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  15. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... and plethysmography were compared in 80 subjects referred for possible vascular disease. In the second part of the study, 31 general practitioners enrolled 1258 consecutive patients aged more than 60 years. ABI was estimated by oscillometry. Patients with an ABI lower than 0.9 were referred to the local hospital...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  16. Portable dynamic light scattering instrument and method for the measurement of blood platelet suspensions

    International Nuclear Information System (INIS)

    Maurer-Spurej, Elisabeth; Brown, Keddie; Labrie, Audrey; Marziali, Andre; Glatter, Otto

    2006-01-01

    No routine test exists to determine the quality of blood platelet transfusions although every year millions of patients require platelet transfusions to survive cancer chemotherapy, surgery or trauma. A new, portable dynamic light scattering instrument is described that is suitable for the measurement of turbid solutions of large particles under temperature-controlled conditions. The challenges of small sample size, short light path through the sample and accurate temperature control have been solved with a specially designed temperature-controlled sample holder for small diameter, disposable capillaries. Efficient heating and cooling is achieved with Peltier elements in direct contact with the sample capillary. Focusing optical fibres are used for light delivery and collection of scattered light. The practical use of this new technique was shown by the reproducible measurement of latex microspheres and the temperature-induced morphological changes of human blood platelets. The measured parameters for platelet transfusions are platelet size, number of platelet-derived microparticles and the response of platelets to temperature changes. This three-dimensional analysis provides a high degree of confidence for the determination of platelet quality. The experimental data are compared to a matrix and facilitate automated, unbiased quality testing

  17. Modification of a two blood sample method used for measurement of GFR with 99mTc-DTPA.

    Science.gov (United States)

    Surma, Marian J; Płachcińska, Anna; Kuśmierek, Jacek

    2018-01-01

    Measurements of GFR may be performed with a slope/intercept method (S/I), using only two blood samples taken in strictly defined time points. The aim of the study was to modify this method in order to extend time intervals suitable for blood sampling. Modification was based on a variation of a Russel et al. model parameter, selection of time intervals suitable for blood sampling and assessment of uncertainty of calculated results. Archived values of GFR measurements of 169 patients with different renal function, from 5.5 to 179 mL/min, calculated with a multiple blood sample method were used. Concentrations of a radiopharmaceutical in consecutive minutes, from 60th to 190th after injection, were calculated theoretically, using archived parameters of biexponential functions describing a decrease in 99mTc-DTPA concentration in blood plasma with time. These values, together with injected activities, were treated as measurements and used for S/I clearance calculations. Next, values of S/I clearance were compared with the multiple blood sample method in order to calculate suitable values of exponent present in a Russel's model, for every combination of two blood sampling time points. A model was considered accurately fitted to measured values when SEE ≤ 3.6 mL/min. Assessments of uncertainty of obtained results were based on law of error superposition, taking into account mean square prediction error and also errors introduced by pipetting, time measurement and stochastic radioactive decay. The accepted criteria resulted in extension of time intervals suitable for blood sampling to: between 60 and 90 minutes after injection for the first sample and between 150 and 180 minutes for the second sample. Uncertainty of results was assessed as between 4 mL/min for GFR = 5-10 mL/min and 8 mL/min for GFR = 180 mL/min. Time intervals accepted for blood sampling fully satisfy nuclear medicine staff and ensure proper determination of GFR. Uncertainty of results is entirely

  18. A statistical method to calculate blood contamination in the measurement of salivary hormones in healthy women.

    Science.gov (United States)

    Behr, Guilherme A; Patel, Jay P; Coote, Marg; Moreira, Jose C F; Gelain, Daniel P; Steiner, Meir; Frey, Benicio N

    2017-05-01

    Previous studies have reported that salivary concentrations of certain hormones correlate with their respective serum levels. However, most of these studies did not control for potential blood contamination in saliva. In the present study we developed a statistical method to test the amount of blood contamination that needs to be avoided in saliva samples for the following hormones: cortisol, estradiol, progesterone, testosterone and oxytocin. Saliva and serum samples were collected from 38 healthy, medication-free women (mean age=33.8±7.3yr.; range=19-45). Serum and salivary hormonal levels and the amount of transferrin in saliva samples were determined using enzyme immunoassays. Salivary transferrin levels did not correlate with salivary cortisol or estradiol (up to 3mg/dl), but they were positively correlated with salivary testosterone, progesterone and oxytocin (phormones in order to determine the level of blood contamination that might affect specific hormonal salivary concentrations. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Electromagnetic flowmetry--an experimental method for continuous blood flow measurement using a new island flap model.

    Science.gov (United States)

    Banis, J C; Schwartz, K S; Acland, R D

    1980-10-01

    We describe a reliable experimental method for direct, continuous measurement of the rate of blood flow in an island skin flap, using an electromagnetic flowmeter applied to the artery of the flap. The canine saphenous island flap model, developed as part of this study, is a large (11 x 14 cm) island flap, based solely on the saphenous artery (2 mm in diameter). We describe the anatomy of the flap and the method of raising it. Electromagnetic flowmetry is the only method of blood flow determination that provides immediate, continuous, and quantitative measurement of flow. We describe the principles and pitfalls of the electromagnetic flowmeter and the numerous rules of practice that must be observed to obtain consistent results. A validation study was carried out, in which we simultaneously measured arterial inflow with the flowmeter and venous outflow from the flap using direct collection. This study was based on the assumption that at any point in time the arterial and venous rate of flow were equal. We present the results of the study, which show an extremely close linear relationship between the measured and actual rates of flow. We intend to use this experimental method to study the factors that affect the rate of blood flow in free skin flap transfer.

  20. Oscillometric and auscultatory blood pressure measurement methods in children: a systematic review and meta-analysis.

    Science.gov (United States)

    Duncombe, Stephanie L; Voss, Christine; Harris, Kevin C

    2017-02-01

    The phase-out of mercury from clinical settings calls for valid alternatives to assess blood pressure (BP) in children. Aneroid devices provide a mercury-free alternative to BP measurements by auscultation, whereas oscillometric (automated) devices are increasingly becoming the norm in clinical practice due to their ease of use. The aim of this systematic review and meta-analysis was to investigate the accuracy of oscillometric and aneroid BP devices compared with the mercury sphygmomanometer for the measurement of BP in children. We systematically searched four electronic databases (MEDLINE, Embase, CINAHL, and Web of Science) and relevant journals for eligible articles published before 30 July 2015. We screened 1415 articles, and two authors independently reviewed 92 full-text articles. We included 29 articles (38 studies) with 26 879 children. Random-effects model meta-analyses revealed that oscillometric devices yield higher measurements of SBP than auscultation with a mercury sphygmomanometer (pooled effect estimate 2.53 mmHg; 95% CI 0.57-4.50; P devices and found comparable results. Oscillometric devices may serve as a suitable alternative to auscultation for initial BP screening in the pediatric population.

  1. Study of Estimation Method for Unsteady Inflow Velocity in Two-Dimensional Ultrasonic-Measurement-Integrated Blood Flow Simulation.

    Science.gov (United States)

    Kadowaki, Hiroko; Hayase, Toshiyuki; Funamoto, Kenichi; Taniguchi, Nobuyuki

    2016-02-01

    Information on hemodynamics is essential for elucidation of mechanisms and development of novel diagnostic methods for circulatory diseases. Two-dimensional ultrasonic-measurement-integrated (2D-UMI) simulation can correctly reproduce an intravascular blood flow field and hemodynamics by feeding back an ultrasonic measurement to the numerical blood flow simulation. In this method, it is critically important to give the correct cross-sectional average inflow velocity (inflow velocity) as the boundary condition. However, systematic study has not been done on the relative validity and effectiveness of existing inflow velocity estimation methods for various target flow fields. The aim of this study was to examine the existing methods systematically and to establish a method to accurately estimate inflow velocities for various vessel geometries and flow conditions in 2D-UMI simulations. A numerical experiment was performed for 2D-UMI simulation of blood flow models in a straight vessel with inflow velocity profiles symmetric and asymmetric to the vessel axis using existing evaluation functions based on Doppler velocity error for the inflow velocity estimation. As a result, it was clarified that a significantly large estimation error occurs in the asymmetric flow due to a nonfeedback domain near the downstream end of the calculation domain. Hence, a new inflow velocity estimation method of 2D-UMI simulation is proposed in which the feedback and evaluation domains are extended to the downstream end. Further numerical experiments of 2D-UMI simulation for two realistic vessel geometries of a healthy blood vessel and a stenosed one confirmed the effectiveness of the proposed method.

  2. Error mechanisms of the oscillometric fixed-ratio blood pressure measurement method.

    Science.gov (United States)

    Liu, Jiankun; Hahn, Jin-Oh; Mukkamala, Ramakrishna

    2013-03-01

    The oscillometric fixed-ratio method is widely employed for non-invasive measurement of systolic and diastolic pressures (SP and DP) but is heuristic and prone to error. We investigated the accuracy of this method using an established mathematical model of oscillometry. First, to determine which factors materially affect the errors of the method, we applied a thorough parametric sensitivity analysis to the model. Then, to assess the impact of the significant parameters, we examined the errors over a physiologically relevant range of those parameters. The main findings of this model-based error analysis of the fixed-ratio method are that: (1) SP and DP errors drastically increase as the brachial artery stiffens over the zero trans-mural pressure regime; (2) SP and DP become overestimated and underestimated, respectively, as pulse pressure (PP) declines; (3) the impact of PP on SP and DP errors is more obvious as the brachial artery stiffens over the zero trans-mural pressure regime; and (4) SP and DP errors can be as large as 58 mmHg. Our final and main contribution is a comprehensive explanation of the mechanisms for these errors. This study may have important implications when using the fixed-ratio method, particularly in subjects with arterial disease.

  3. Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    International Nuclear Information System (INIS)

    Hachiya, Takenori; Inugami, Atsushi; Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using 99m Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99m Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  4. Gingival blood flow under total combs by functional pressure evaluated with laser-Doppler flowmetry, a non-invasive method of blood flow measurement

    International Nuclear Information System (INIS)

    Hengl, St.

    1996-09-01

    Gingival blood flow under total-combs by functional pressure evaluated with Laser-Doppler Flowmetry, a non-invasive method of blood flow measurement. Microcirculation of gum's capillary system can be measured non-invasive by Laser-Doppler-Flowmetry (LDF). Circulation, defined by the number of floating erythrocytes per unit of time, is measured by a fibro-optical Laser-Doppler-Flowmetry. The task was to examine, if there is any change of gum's circulation during strain and relief. Circulation on defined measurepoints, divided on the four quadrants, was determined among maximal strain and subsequent relief, on one probationer (complete denture bearer). Before every measure session systemic pressure was taken. LDF-value was taken on top of jaw-comb, in doing so, to get reproducible result and a satisfying fixation of the probe, there was made an artificial limb of the upper and lower comb. In the upper comb a dynamometer-box, which determined minimal and maximal comb pressure, was integrated. The received results of the LDF-measurement, expressed as perfusion units (PU) were lower under applied pressure than by pressure points more distant. Hyperemia, resulting during relief, seemed the more intense, the less perfusion was before. This new, non-invasive kind of circulation measurement seems to be quite predestined to be used for gingival diagnostic under artificial limb in the future. (author)

  5. Regional cerebral blood flow measurements in schizophrenics by /sup 133/Xe inhalation and intra-venous injection method

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Seki, Hiroyasu; Sumiya, Hisashi; Ishida, Hiroko; Taki, Junichi; Hisada, Kinichi; Kurachi, Masayoshi; Kobayashi, Katsuji; Yamaguchi, Nariyoshi (Kanazawa Univ. (Japan). School of Medicine)

    1984-12-01

    Regional cerebral blood flow measurements were performed in 25 schizophrenic patients and 25 healthy volunteers by /sup 133/Xe inhalation and intra-venous injection method. Schizophrenic patients were classified into the following three groups. Group I: 8 patients without auditory hallucination measured by 2-dimensional /sup 133/Xe inhalation method. Group II: 6 patients with auditory hallucination measured by the same method as in Group I. Group III: 11 patients, including 2 patients with auditory hallucination measured by 3-dimensional /sup 133/Xe intra-venous injection method at the level of OM+5 cm. Bilateral regional percent values, which were obtained by dividing regional values by hemispheric mean or sectional mean values, for frontal lobes in Group I and II were significantly lower than those in the controls. In addition, bilateral regional percent values for bilateral temporal lobes in Group II were significantly higher than those in the controls. In Group III, regional percent values for right frontal lobes and those for posterior part of central gray matter showed significant decrease and increase, respectively. These findings would suggest that the negative symptoms of schizophrenia are related to the hypofrontal and positive ones to the hypertemporoparietal activity.

  6. Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems.

    Science.gov (United States)

    Romagnoli, Stefano; Romano, Salvatore Mario; Bevilacqua, Sergio; Lazzeri, Chiara; Gensini, Gian Franco; Pratesi, Carlo; Quattrone, Diego; Dini, Daniele; De Gaudio, Angelo Raffaele

    2011-08-01

    We aimed to compare the effects of a blood pressure transducer system specifically manufactured to limit underdamping artifacts with those of a standard system on hemodynamic parameter estimation and accuracy. Forty-three consecutive patients undergoing vascular surgery at the University of Florence, Italy, were included. Arterial blood pressure signal was simultaneously registered with 2 MostCare monitors, connected to the artery either by a standard transducer or a specific transducer manufactured to avoid underdamping artifacts (Resonance Over-Shoot Eliminator [R.O.S.E.]; Becton Dickinson, Becton Drive, NJ). Patients were divided into 2 groups: absence (C group) or presence (R group) of underdamping/resonance artifacts of blood pressure signal. Systolic blood pressure, cardiac index, maximal pressure/time ratio (dP/dt(MAX)), and cardiac cycle efficiency were recorded every 30 seconds for 30 minutes. A total of 2675 measurements were performed with 34.9% incidence of underdamping/resonance artifacts. All hemodynamic parameters showed clinically acceptable differences in the C group; in contrast, the results differed greatly in the R group between standard and R.O.S.E. transducer (systolic blood pressure bias, 16.7 mm Hg; cardiac index bias, 0.24 L min(-1) m(-2); dP/dt(MAX) bias, 0.92 mm Hg/ms; cardiac cycle efficiency bias, 0.018 units). Underdamping/resonance artifacts frequently affect blood pressure measurement in operating rooms and intensive care units and cause severe overestimation of systolic blood pressure and incorrect estimation of hemodynamic parameters when the pulse contour method is used. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  8. Regional brain blood flow in mouse: quantitative measurement using a single-pass radio-tracer method and a mathematical algorithm.

    Science.gov (United States)

    Xu, K; Radhakrishnan, K; Serhal, A; Allen, F; Lamanna, J C; Puchowicz, M A

    2011-01-01

    We have developed a reliable experimental method for measuring local regional cerebral blood flows in anesthetized mice. This method is an extension of the well-established single-pass dual-label indicator method for simultaneously measuring blood flow and glucose influx in rat brains. C57BL6J mice (n = 10) were anesthetized and regional blood flows (ml/min/g) were measured using the radio-tracer method. To test the sensitivity of this method we used a mathematical algorithm to predict the blood flows and compared the two sets of results.Measured regional blood flows between 0.7 and 1.7 ml/min/g were similar to those we have previously reported in the rat. The predicted blood flows using an assumed linearly increasing arterial tracer concentration-versus-time profile (that is, a ramp) were similar to the values measured in the physiological experiments (R(2) 0.99; slope 0.91). Thus,measurements of local regional cerebral blood flow in anesthetized mice using a single-pass radio-tracer method appear to be reliable.

  9. Methodical aspects of blood coagulation measurements in birds applying commercial reagents--a pilot study.

    Science.gov (United States)

    Guddorf, Vanessa; Kummerfeld, Norbert; Mischke, Reinhard

    2014-01-01

    The aim of this study was to examine the suitability of commercially available reagents for measurements of coagulation parameters in citrated plasma from birds. Therefore, plasma samples of 17 healthy donor birds of different species were used to determine prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT) applying various commercial reagents which are routinely used in coagulation diagnostics in humans and mammals. A PT reagent based on human placental thromboplastin yielded not only shorter clotting times than a reagent containing recombinant human tissue factor (median 49 vs. 84 s), but also showed a minor range of distribution of values (43-55 s vs. 30-147 s, minimum-maximum, n = 5 turkeys). An aPTT reagent containing kaolin and phospholipids of animal origin delivered the shortest clotting times and the lowest range of variation in comparison to three other reagents of different composition. However, even when this reagent was used, aPTTs were partially extremely long (> 200 s). Thrombin time was 38 s (28-57 s, n = 5 chicken) when measured with bovine thrombin at a final concentration of 2 IU thrombin/ ml. Coefficients of variation for within-run precision analysis (20 repetitions) of PT was 8.0% and 4.7% for aPTT measurements using selected reagents of mammalian origin. In conclusion, of the commercially available reagents tested, a PT reagent based on human placental thromboplastin and an aPTT reagent including rabbit brain phospholipid and kaolin, show some promise for potential use in birds.

  10. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  11. Focal cerebral ischemia measured by the intra-arterial 133xenon method. Limitations of 2-dimensional blood flow measurements

    DEFF Research Database (Denmark)

    Skyhøj Olsen, T; Larsen, B; Bech Skriver, E

    1981-01-01

    The limitations of 2-dimensional isotope techniques in the study of focal cerebral ischemia were investigated using the intra-carotid 133 xenon injection method and a 254 multidetector scintillation camera. To make sure that the detectors "look" directly on infarcted areas, only patients with inf...

  12. Effect of prewarming the forearm on the measurement of regional cerebral blood flow with one-point venous sampling by autoradiography method

    International Nuclear Information System (INIS)

    Itoh, Youko H.; Kurabe, Teruhisa; Kazaoka, Yoshiaki; Ishiguchi, Tsuneo; Kawashima, Sadao

    2004-01-01

    Autoradiography (ARG) using 123 I-iodoamphetamine ( 123 I-IMP) is widely performed as an efficient method of measuring local cerebral blood flow. Recently, ARG by a single collection of venous blood has been appreciated as a simple method. In this study, we investigated the effect of warming of the site for collecting venous blood (forearm). The coefficient of correlation of the local cerebral blood flow value obtained from arterial and venous blood samples was 0.766 (p<0.05) in the group without warming (38 patients). The coefficient of correlation similarly obtained in the group with warming (53 patients) was 0.908 (p<0.05). The difference in the correlation efficient was significant (p<0.05) between the two groups. From these results it was concluded that warming the blood-collecting site decreased the difference between the arterial and venous radioactive concentrations and increased the precision of the test. (author)

  13. Early changes in blood flow of the mouse skin after irradiation as measured by the 133Xe clearance method

    International Nuclear Information System (INIS)

    Tsujii, Hirohiko; Irie, Goro

    1983-01-01

    The early effects of radiation on the local blood flow in the skin of mice were evaluated by measuring the local clearance rate of 133 Xe after its subcutaneous injection; this was done at four to five weeks after irradiation during the animals' normal resting conditions. The fractionation schedules employed were single fractions, two fractions in 15 days and four fractions in 15 days. The dose effect curves with these schedules showed a two-component pattern. There was a uniform reduction in flood flow after 10 to 30 Gy, and a steady increase in flood flow after doses more than 40 Gy. The blood flow after higher-fractionated doses was always lower than less-fractionated doses. It was considered that radiation doses causing higher severity of acute skin reactions might have predominated a degree of acute vasodilatation over fibrotic changes, thus resulting in increased blood flow. A steady increase in early blood flow was observed with increasing severity of acute skin reactions, but the early blood flow was not a good indicator for predicting late skin reactions, except for a severe leg deformity which was accompanied with a significant increase in early blood flow. (author)

  14. Preliminary Clinical Validation of a Differential Correction Method for Improving Measurement Accuracy in Noninvasive Measurement of Blood Glucose Using Near-Infrared Spectroscopy.

    Science.gov (United States)

    Han, Guang; Yu, Xuyao; Xia, Dandan; Liu, Rong; Liu, Jin; Xu, Kexin

    2017-09-01

    One of the main challenges in the noninvasive sensing of blood glucose by near-infrared (NIR) spectroscopy is the background variations from light source drift, sweating, and temperature change at the human-machine interface. In this paper, a differential correction method based on the spectra from the floating-reference position and measuring position is proposed to eliminate these spectral variations from background interferences. Its effectiveness was validated by in vitro and in vivo experiments in which the diffuse reflectance of intralipid solutions and human skin was collected at the source distances of 0.6 mm and 2 mm by the custom-built system with six super-luminescent emitting diodes (SLEDs) light source. The results showed that, for the in vitro experiments of intralipid solutions, the coefficients of variations of diffuse reflectance decreased by 20.5% under all the six wavelengths after differential correction. For the in vivo experiments of oral glucose tolerance tests (OGTTs), partial least squares (PLS) regression models between glucose concentrations and the diffuse reflectance from palm skin were built, and the root mean square error of cross validation (RMSECV) decreased by 38.0% on average after the differential correction. Further, the spectra of the oral water tolerance tests (OWTTs) were collected for correlation with glucose concentration in OGTTs, and their correlation coefficients (R) decreased by 35.0% on average after the differential correction. Therefore, this differential correction method based on the spectra from the floating-reference position and measuring position can weaken the influence of background variations on the NIR spectroscopy and has promising potential in in vivo detection, especially for noninvasive blood glucose measurement.

  15. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  16. Effects of antipsoriatic treatment on cutaneous blood flow in psoriasis measured by 133Xe washout method and laser Doppler velocimetry

    International Nuclear Information System (INIS)

    Klemp, P.; Staberg, B.

    1985-01-01

    In 8 patients with psoriasis vulgaris, the cutaneous blood flow (CBF) was measured simultaneously in both involved and uninvolved psoriatic skin before (i.e., on the first day of hospitalization) and on the 3rd, 7th, 14th, and 28th days of treatment with tar. The 133 Xe washout method was used after epicutaneous labeling and compared to the laser Doppler velocimetry (LDV) technique. Control experiments were performed in 10 normal individuals. Before treatment the mean CBF in involved psoriatic skin was 62.6 +/- 18.7 SD ml X (100 g X min)-1, which is significantly higher than CBF of uninvolved skin in psoriatic patients, 9.5 +/- 4.0 SD ml X (100 g X min)-1, (p less than 0.01) and is 13.6 times higher than CBF in the normal individuals (p less than 0.01). Fifty hours following onset of treatment (i.e., after only 2 applications of tar), mean CBF of the involved psoriatic skin had decreased significantly to 35.0 +/- 13.9 SD ml X (100 g X min)-1, (p less than 0.01), which was not statistically different from the CBF on the 7th day. During the following weeks, the CBF in involved psoriatic skin decreased at a more moderate rate than that observed during the first week and was 15.0 +/- 6.1 SD ml X (100 g X min)-1 on the 28th day. This value is not significantly different from the CBF of uninvolved skin in these patients. At the end of treatment, the CBF of the uninvolved skin had decreased significantly (p less than 0.05) in all the patients to values similar to those observed in the skin of normal individuals. A parallel decline was observed in a clinical psoriatic score index; however, it is not known whether the observed decrease in CBF was preceded or succeeded by the clinical improvement

  17. Wrist blood pressure-measuring devices: a comparative study of accuracy with a standard auscultatory method using a mercury manometer.

    Science.gov (United States)

    Altunkan, Sekip; Yildiz, Sevil; Azer, Sabir

    2002-10-01

    In this study, we compared two wrist blood pressure-measuring devices, the Omron RX and the Nissei WS-310, against a mercury manometer. A total of 152 subjects attending an out-patient hypertensive clinic were recruited from a randomized blood pressure survey, 87 patients (mean 44.4 +/- 14.5 years of age) being selected according to the Association for the Advancement of Medical Instrumentation/British Hypertension Society standards. Device validation was assessed through the use of sequential same-arm readings compared with readings taken using a mercury sphygmomanometer by the two trained observers. There were no differences between the observers and the monitors for diastolic readings (2.8 +/- 4.8 mmHg for the Omron and 4.2 +/- 6.4 mmHg for the Nissei) according to the Association for the Advancement of Medical Instrumentation standards. The largest standard deviations -- 8.3 mmHg for the Omron and 8.8 mmHg for the Nissei, respectively -- were seen for systolic readings recorded by the observers and the monitors. According to the British Hypertension Society standards, the Omron achieved an A grade for diastolic readings and a B grade for systolic readings within 5 and 10 mmHg. The Nissei monitor achieved an A grade for diastolic readings and a B grade for systolic readings within 5 and 10 mmHg. Patients found the wrist oscillometric devices that we tested to be comfortable and easy to use. These devices are appropriate for measuring diastolic blood pressure according to the standards, but the reliability of both devices decreased when measuring systolic blood pressure.

  18. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  19. A simple and rapid method for measurement of 10B-para-boronophenylalanine in the blood for boron neutron capture therapy using fluorescence spectrophotometry

    International Nuclear Information System (INIS)

    Kashino, Genro; Fukutani, Satoshi; Suzuki, Minoru

    2009-01-01

    10 B deriving from 10 B-para-boronophenylalanine (BPA) and 10 B-borocaptate sodium (BSH) have been detected in blood samples of patients undergoing boron neutron capture therapy (BNCT) using prompt gamma ray spectrometer or Inductively Coupled Plasma (ICP) method, respectively. However, the concentration of each compound cannot be ascertained because boron atoms in both molecules are the target in these assays. Here, we propose a simple and rapid method to measure only BPA by detecting fluorescence based on the characteristics of phenylalanine. 10 B concentrations of blood samples from human or mice were estimated by the fluorescence intensities at 275 nm of a BPA excited by light of wavelength 257 nm using a fluorescence spectrophotometer. The relationship between fluorescence to increased BPA concentration showed a positive linear correlation. Moreover, we established an adequate condition for BPA measurement in blood samples containing BPA, and the estimated 10 B concentrations of blood samples derived from BPA treated mice were similar between the values obtained by our method and those by ICP method. This new assay will be useful to estimate BPA concentration in blood samples obtained from patients undergoing BNCT especially in a combination use of BSH and BPA. (author)

  20. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  1. Development of quantification analysis software for measuring regional cerebral blood flow by the modified split-dose method with 123I-IMP before and after acetazolamide loading

    International Nuclear Information System (INIS)

    Nagaki, Akio; Kobara, Kouichi; Matsutomo, Norikazu

    2003-01-01

    We developed a quantification analysis software program for measuring regional cerebral blood flow (rCBF) at rest and under acetazolamide (ACZ) stress by the modified split-dose (MSD) method with iodine-123 N-isopropyl-p-iodoamphetamine (IMP) and compared the rCBF values measured by the MSD method and by the split dose 123 I-IMP SPECT (SD) method requiring one continuous withdrawal of arterial blood. Since the MSD method allows the input of two arterial blood sampling parameter values, the background subtraction procedure for obtaining ACZ-induced images in the MSD method is not identical to the procedure in the SD method. With our software program for rCBF quantification, the resting rCBF values determined by the MSD method were closely correlated with the values measured by the SD method (r=0.94), and there was also a good correlation between the ACZ-induced rCBF values obtained by the MSD method and by the SD method (r=0.81). The increase in rCBF under ACZ stress was estimated to be approximately 26% by the SD method and 38% by the MSD method, suggesting that the MSD method tends to overestimate the increase in rCBF under ACZ stress in comparison with the SD method, but the variability of the rCBF values at rest and during ACZ stress analyzed by the MSD method was smaller than the variability with the SD method. Further clinical studies are required to validate our rCBF quantification analysis program for the MSD method. (author)

  2. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  3. A simplified method for the measurement of nonmetabolized 2-[{sup 18}F]F-A-85380 in blood plasma using solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Shumway, Dean A. [Neuroimaging Research Branch, National Institute on Drug Abuse, Intramural Research Program, NIH, DHHS, Baltimore, MD 21224 (United States); Pavlova, Olga A. [Neuroimaging Research Branch, National Institute on Drug Abuse, Intramural Research Program, NIH, DHHS, Baltimore, MD 21224 (United States); Mukhin, Alexey G. [Neuroimaging Research Branch, National Institute on Drug Abuse, Intramural Research Program, NIH, DHHS, Baltimore, MD 21224 (United States)]. E-mail: amukhin@intra.nida.nih.gov

    2007-02-15

    Quantification of {alpha}{sub 4}{beta}{sub 2}* nicotinic acetylcholine receptors using 2-[{sup 18}F]fluoro-3-(2(S)-azetidinylmethoxy)pyridine (2-[{sup 18}F]FA) and positron emission tomography (PET) imaging requires measurement of nonmetabolized radioligand in blood plasma, which was previously accomplished using high-performance liquid chromatography (HPLC). Here, we introduce a one-step solid-phase extraction (SPE) method for measuring the concentration of nonmetabolized 2-[{sup 18}F]FA. This method allows many samples to be processed in a short period of time. SPE effectively separated 2-[{sup 18}F]FA from radioactive metabolites typically observed in blood plasma after administration of radioligand in humans. Measurements of the 2-[{sup 18}F]FA parent fraction in healthy human volunteers obtained using the SPE method were nearly identical to those obtained using HPLC (1.3{+-}5% average underestimation of SPE), and reproducibility was good within and between runs (2% and 6% coefficient of variation, respectively). SPE recovery of 2-[{sup 18}F]FA from blood plasma was not appreciably diminished (3{+-}0.6%) by a larger volume of blood plasma loaded onto the cartridge, suggesting the possibility of increasing the plasma sample volume at later times in a PET study to improve measurement sensitivity. 2-[{sup 18}F]FA was stable in blood stored on ice over 8 h and in saline at low concentrations (<2 MBq/ml) but not at high concentrations (ca. 130 MBq/ml). Using SPE, the elimination half-life and full body distribution volume of 2-[{sup 18}F]FA in healthy human volunteers were estimated as 4.2{+-}0.8 h and 220{+-}70 L, respectively. These results suggest that SPE is the method of choice for the determination of the plasma 2-[{sup 18}F]FA concentration when measurement of individual metabolites is not required.

  4. A simplified method for the measurement of nonmetabolized 2-[18F]F-A-85380 in blood plasma using solid-phase extraction

    International Nuclear Information System (INIS)

    Shumway, Dean A.; Pavlova, Olga A.; Mukhin, Alexey G.

    2007-01-01

    Quantification of α 4 β 2 * nicotinic acetylcholine receptors using 2-[ 18 F]fluoro-3-(2(S)-azetidinylmethoxy)pyridine (2-[ 18 F]FA) and positron emission tomography (PET) imaging requires measurement of nonmetabolized radioligand in blood plasma, which was previously accomplished using high-performance liquid chromatography (HPLC). Here, we introduce a one-step solid-phase extraction (SPE) method for measuring the concentration of nonmetabolized 2-[ 18 F]FA. This method allows many samples to be processed in a short period of time. SPE effectively separated 2-[ 18 F]FA from radioactive metabolites typically observed in blood plasma after administration of radioligand in humans. Measurements of the 2-[ 18 F]FA parent fraction in healthy human volunteers obtained using the SPE method were nearly identical to those obtained using HPLC (1.3±5% average underestimation of SPE), and reproducibility was good within and between runs (2% and 6% coefficient of variation, respectively). SPE recovery of 2-[ 18 F]FA from blood plasma was not appreciably diminished (3±0.6%) by a larger volume of blood plasma loaded onto the cartridge, suggesting the possibility of increasing the plasma sample volume at later times in a PET study to improve measurement sensitivity. 2-[ 18 F]FA was stable in blood stored on ice over 8 h and in saline at low concentrations ( 18 F]FA in healthy human volunteers were estimated as 4.2±0.8 h and 220±70 L, respectively. These results suggest that SPE is the method of choice for the determination of the plasma 2-[ 18 F]FA concentration when measurement of individual metabolites is not required

  5. Effect of sumatriptan on cerebral blood flow during migraine headache. Measurement by sequential SPECT used 99mTc-ECD background subtraction method

    International Nuclear Information System (INIS)

    Ueda, Takashi; Torihara, Yoshito; Tsuneyoshi, Noritaka; Ikeda, Yoshitomo

    2001-01-01

    The present study was designed to examine the effect of sumatriptan on regional cerebral blood flow (CBF) during migraine headache. Nine cases were examined by 99m Tc-ECD background subtraction method for the absolute value measurement of regional CBF before and after sumatriptan injection. rCBF except for occipital and perioccipital lobes, were increased 10-20% during migraine headache and significant decreases were observed by sumatriptan injection. Two cases of nine had transiently increased systemic blood pressure and cardiac pulse rate, however, all cases improved migraine headache after injection of sumatriptan. (author)

  6. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  7. Preclinical Arterial Spin Labeling Measurement of Cerebral Blood Flow.

    Science.gov (United States)

    Muir, Eric R

    2018-01-01

    Magnetic resonance imaging has been utilized as a quantitative and noninvasive method to image blood flow. Arterial spin labeling (ASL) is an MRI technique that images blood flow using arterial blood water as an endogenous tracer. Herein we describe the use of ASL to measure cerebral blood flow completely noninvasively in rodents, including methods, analysis, and important considerations when utilizing this technique.

  8. Insuring quality during implementation of a SPEDT method of regional cerebral blood flow measurements into daily routine

    International Nuclear Information System (INIS)

    Mathiassen, B.; Landsfeldt, U.S.; Broechner-Mortensen, J.; Andersen, A.R.; Pedersen, B.; Roedbro, P.

    1995-01-01

    The present aim was to describe a method for quality insurance when a previously experimental technique is implemented for daily clinical use. Regional cerebral blood flow (rCBF) was studied in 24 patients with medically intractable complex partial epilepsy using SPECT of the Tc99m-HMPAO distribution. The colour-coded rCBF images were evaluated visually four times by four observers who classified each data set into one of four ranked classes (normal, slightly - , median - or severely abnormal). The visual analysis was compared to the results obtained by an expert (the standard). After two evaluation rounds a teaching session of image interpretation was performed with emphasis on the most difficult problem cases. The results of the primary evaluation and the yield of the teaching round was assessed by error-points depending on the magnitude of the misinterpretation of each data set. Interobserver discrepancies was analyzed by Friedman's test of variance, while intra-observer variability was evaluated by Wilcoxon's paired non-parametric test. The teaching round improved the performance of the four observers significantly (p=0.0004), but not to the wanted quality standard for all observers. The reproducibility was improved in all, but not significantly. The insurance of quality during implementation of a new diagnostic method can thus be performed in a simple way providing the steering team with identification of problems, as well as inspiration to solution of critical problems. The presented quality insurance method can easily be performed when other imaging modalities are started or when quality control of a routine method is needed. (au)

  9. Neonatal blood gas sampling methods

    African Journals Online (AJOL)

    adequate collateral circulation before radial arterial puncture may not be a reliable predictor of subsequent risk of vascular injury.75. Conclusion and recommendations. Indwelling arterial catheters remain a practical, reliable and accurate method of neonatal blood gas sampling, provided they are inserted and maintained ...

  10. Comparison of capillary blood ketone measurement by electrochemical method and urinary ketone in treatment of diabetic ketosis and ketoacidosis in children.

    Science.gov (United States)

    Turan, Serap; Omar, Anjumanara; Bereket, Abdullah

    2008-06-01

    We aimed to compare the recent practical method of capillary beta-hydroxy butyrate (betaOHB) measurement with the widely used urinary ketone measurement in monitoring metabolic status of the patient during treatment of diabetic ketoacidosis (DKA) and diabetic ketosis (DK). Patients with DKA and DK admitted to the hospital were followed with simultaneous measurements of capillary betaOHB by electrochemical method (Medisense Optium, Abbott), and urinary ketone by semi-quantitative method. Blood gases were measured in 2-4 h intervals. Fourteen patients with DKA/DK (7 males and 7 females, age: 9.2 +/- 4.2 years) were included with 50 simultaneous measurements of capillary and urinary ketone. No correlation was detected between urinary ketone and blood pH (P = 0.06) and HCO3 (P = 0.79), whereas a significant negative correlation was found between capillary betaOHB and blood pH (r = -0.41, P < 0.05) and HCO3 (r = -0.35, P < 0.05). Capillary betaOHB and urinary ketone levels did not correlate at the beginning and 3.3 +/- 1.4 h after treatment, but did correlate in the third samples taken 7.8 +/- 2.0 h after treatment (r = 0.8, P < 0.05). Capillary betaOHB levels show good correlation with the degree of acidosis (pH and HCO3). Capillary betaOHB measurement is more sensitive than urinary ketone measurement in reflecting the patient's metabolic status and improvement during treatment.

  11. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  12. Simultaneous measurement of local glucose utilization and blood flow in the rat brain: an autoradiographic method using two tracers labeled with carbon-14

    International Nuclear Information System (INIS)

    Furlow, T.W. Jr.; Martin, R.M.; Harrison, L.E.

    1983-01-01

    A simplified technique that uses two radionuclide tracers has been devised to measure local cerebral glucose utilization (ICGU) and local cerebral blood flow (ICBF) in the same rat. The method employs [ 14 C]-2-deoxyglucose and [ 14 C]iodoantipyrine to produce an autoradiogram before and another after extraction into chloroform of the [ 14 C]iodoantipyrine from the brain sections. The chloroform-extracted autoradiogram yields ICGU, and the difference in tissue carbon-14 concentration between the two autoradiograms permits calculation of ICBF. The double-isotope technique provides values of ICGU and ICBF that are statistically indistinguishable from those derived from conventional single-isotope methods

  13. [Invasive blood pressure measurements. Factual safety].

    Science.gov (United States)

    Nielsen, L H

    1994-08-01

    Intra-arterial blood pressure measurement is often used in patients with unstable haemodynamics. The demand for accuracy in such measurements is high. Usually these demands are fulfilled, but situations can occur where the dynamic characteristics of the system are exceeded. In order to acknowledge this situation, one must be aware of these dynamic characteristics. The significance of the system's resonance frequency and damping is described. A method to control the usability of the system is described.

  14. Development and validation of a sensitive UPLC-MS/MS method for the quantitation of [(13)C]sucrose in rat plasma, blood, and brain: Its application to the measurement of blood-brain barrier permeability.

    Science.gov (United States)

    Miah, Mohammad K; Bickel, Ulrich; Mehvar, Reza

    2016-03-15

    Accurate and reproducible measurement of blood-brain barrier (BBB) integrity is critical in the assessment of the pathophysiology of the central nervous system disorders and in monitoring therapeutic effects. The widely-used low molecular weight marker [(14)C]sucrose is non-specific in the absence of chromatographic separation. The purpose of this study was to develop and validate a sensitive and reproducible LC-MS/MS method for the analysis of stable isotope-modified [(13)C12]sucrose in brain, plasma, and blood to determine BBB permeability to sucrose. After addition of internal standard (IS, [(13)C6]sucrose), the marker and IS were recovered from diluted rat blood, plasma, and brain homogenate by protein precipitation using acetonitrile. The recovery of the marker and IS was almost quantitative (90-106%) for all three matrices. The recovered samples were directly injected into an isocratic UPLC system with a run time of 6 min. Mass spectrometry was conducted using multiple reaction monitoring in negative mode. The method was linear (r(2)≥0.99) in the concentration ranges tested for the diluted blood and plasma (10-1000 ng/mL) and brain homogenate (1-200 ng/mL). The lower limit of quantitation of the assay was 0.5 pg injected on column. The assay was validated (n=5) based on acceptable intra- and inter-run accuracy and precision values. The method was successfully used for the measurement of serial blood and plasma and terminal brain concentrations of [(13)C12]sucrose after a single intravenous dose (10 mg/kg) of the marker to rats. As expected, the apparent brain uptake clearance values of [(13)C12]sucrose were low in healthy rats. The method may be useful for determination of the BBB integrity in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Measurement of blood pressure using the auscultatory and oscillometric methods in the same cuff deflation: validation and field trial of the A&D TM2421 monitor.

    Science.gov (United States)

    Keavney, B; Bird, R; Caiazza, A; Casadei, B; Conway, J

    2000-09-01

    We have evaluated under laboratory validation conditions and in an extensive field trial the behaviour of an ambulatory monitoring device that is capable of recording both by the Korotkoff-sound and oscillometric methods in a single cuff deflation (TM2421: A&D Co, Tokyo, Japan). The effects of subject age and blood pressure (BP) level on the accuracy and field reliability of the two methods implemented in the device have been determined. In the validation phase, automatic BP measurements were compared with readings by two trained observers in 96 subjects, and the results compared with the AAMI criteria for automatic BP monitors. In the field trial phase, the performances of Korotkoff-sound and oscillometric methods over a 24-h period of ambulatory BP monitoring were compared in 515 subjects, with analysis of the agreement between the two methods in patients where both provided satisfactory recordings. In the validation phase, the Korotkoff-sound method gave satisfactory results for both systolic and diastolic BP, but the oscillometric technique narrowly failed to meet the AAMI criteria for the measurement of either systolic or diastolic BP. In the field trial, the K-sound method failed to record BP accurately in 12% of subjects whereas the oscillometric method was successful in all of these. Where both methods provided technically adequate records, agreement between mean values for each method was close. In 18% of patients, the availability of the oscillometric measurement as a 'back-up' method for the K-sound method significantly improved the number of available measurements in the monitoring period, which should result in improved accuracy and reproducibility of the ambulatory mean values.

  16. [Measurements of vancomycin concentrations in the blood - a method of personalization the antibiotic therapy in patients with chronic kidney disease].

    Science.gov (United States)

    Pondel, Joanna; Krajewski, Piotr; Królikowska, Natalia; Tobiasz, Aleksandra; Augustyniak-Bartosik, Hanna; Hurkacz, Magdalena

    2017-04-21

    Therapeutic Drug Monitoring is a recognized method of personalizing treatment, having particular application in patients with chronic kidney disease who have frequent infections, requiring administration of vancomycin. International guidelines indicate the need to adjust the dose of the drug to the state of renal function. The recommended therapeutic ranges of minimum and maximum levels should be achieved in order to increase the effectiveness and safety of treatment. The aim of this study was to evaluate the usefulness of measuring the concentration of vancomycin in patients with chronic kidney disease due to bacterial infection. The study included 96 adult patients with chronic kidney disease of varying severity treated with vancomycin Patients were divided into 3 groups: treated by haemodialysis (hd), after renal transplantations (ktx), do not require renal replacement therapy (nef). In subjects were examined the minimum and maximum concentrations of vancomycin in steady-state and were compared with recommended therapeutic ranges. Statistically significant decrease of inflammatory markers was observed only in patients treated with dialysis. In the other groups not significant changes in values of inflammatory parameters were confirmed. Trough concentrations of vancomycin marked in patients were consistent with the recommendation of EUCAST, but exceeded the value recommended by the manufacturers of the drug. Considering absolute values of the minimum concentrations, only about 50% of patients achieved the therapeutic range (58% for recommendation EUCAST and 36% for the manufacturer's instructions). Peak concentration values indicated in dialyzed patients were below the prescribed range of 20-50 mg/l and averaged 17.7 mg / l. In the other subgroups they were correct. The rating of the absolute values of the peak concentrations of vancomycin also showed that only 46% (64% in the ktx, 30% - hd and 53% - nef) was within the recommended range, while 50% were

  17. Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond

    Science.gov (United States)

    Drawz, Paul E.; Abdalla, Mohamed; Rahman, Mahboob

    2014-01-01

    Blood pressure has traditionally been measured in the clinic setting using the auscultory method and a mercury sphygmomanometer. Technological advances have led to improvements in measuring clinic blood pressure and allowed for measuring blood pressures outside the clinic. This review outlines various methods for evaluating blood pressure and the clinical utility of each type of measurement. Home blood pressures and 24 hour ambulatory blood pressures have improved our ability to evaluate risk for target organ damage and hypertension related morbidity and mortality. Measuring home blood pressures may lead to more active participation in health care by patients and has the potential to improve blood pressure control. Ambulatory blood pressure monitoring enables the measuring nighttime blood pressures and diurnal changes, which may be the most accurate predictors of risk associated with elevated blood pressure. Additionally, reducing nighttime blood pressure is feasible and may be an important component of effective antihypertensive therapy. Finally, estimating central aortic pressures and pulse wave velocity are two of the newer methods for assessing blood pressure and hypertension related target organ damage. PMID:22521624

  18. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    , but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two......-day workshop on the design, use and evaluation of prediction methods for blood glucose concentration was held at the Johannes Kepler University Linz, Austria. One intention of the workshop was to bring together experts working in various fields on the same topic, in order to shed light from different angles...... Freckmann et al. discusses performance metrics used to characterize the accuracy of continuous glucose measurement devices. This topic is highly relevant for prediction models since many of them rely on the data given by the continuous sensors which are previously calibrated with blood glucose meter...

  19. Clinical value of blood pressure measurement in the community pharmacy.

    Science.gov (United States)

    Sabater-Hernández, Daniel; Azpilicueta, Inés; Sánchez-Villegas, Pablo; Amariles, Pedro; Baena, María I; Faus, María J

    2010-10-01

    To investigate whether the measurement of blood pressure in the community pharmacy is a valuable method to diagnose hypertension, to assess the need and the effectiveness of anti-hypertensive treatments, or, in general, to make clinical decisions. Information has been extracted from articles published in English and in Spanish, from January 1989 to December 2009, in indexed magazines in MEDLINE and EMBASE. To perform the search, multiple and specified terms related to the community pharmacy setting, to blood pressure measurement and to the comparison and agreement between blood pressure measurement methods were used. Selected articles were those that: (1) compared and/or measured the agreement (concordance) between community pharmacy blood pressure measurements obtained in repeated occasions, or (2) compared and/or measured the agreement between the community pharmacy blood pressure measurement method and other measurement methods used in clinical practice for decision-making purposes: blood pressure measurement by a physician, by a nurse and home or ambulatory blood pressure monitoring. Articles were included and analyzed by two investigators independently, who essentially extracted the main results of the manuscripts, emphasizing the assessment of the blood pressure measurement methods used and the completed statistical analysis. Only three studies comparing the community pharmacy blood pressure measurement method with other methods and one comparing repeated measurements of community pharmacy blood pressure were found. Moreover, these works present significant biases and limitations, both in terms of method and statistical analysis, which make difficult to draw consistent conclusions. Further research of high quality is needed, which results can guide the clinical decision-making based on the community pharmacy blood pressure measurement method.

  20. A simple dried blood spot-method for in vivo measurement of ureagenesis by gas chromatography-mass spectrometry using stable isotopes.

    Science.gov (United States)

    Allegri, Gabriella; Deplazes, Sereina; Grisch-Chan, Hiu Man; Mathis, Déborah; Fingerhut, Ralph; Häberle, Johannes; Thöny, Beat

    2017-01-01

    Clinical management of inherited or acquired hyperammonemia depends mainly on the plasma ammonia level which is not a reliable indicator of urea cycle function as its concentrations largely fluctuate. The gold standard to assess ureagenesis in vivo is the use of stable isotopes. Here we developed and validated a simplified in vivo method with [ 15 N]ammonium chloride ([ 15 N]H 4 Cl) as a tracer. Non-labeled and [ 15 N]urea were quantified by GC-MS after extraction and silylation. Different matrices were evaluated for suitability of analysis. Ureagenesis was assessed in ornithine transcarbamylase (OTC)-deficient spf ash mice with compromised urea cycle function during fasted and non-fasted feeding states, and after rAAV2/8-vector delivery expressing the murine OTC-cDNA in liver. Blood (5μL) was collected through tail vein puncture before and after [ 15 N]H 4 Cl intraperitoneal injections over a two hour period. The tested matrices, blood, plasma and dried blood spots, can be used to quantify ureagenesis. Upon [ 15 N]H 4 Cl challenge, urea production in spf ash mice was reduced compared to wild-type and normalized following rAAV2/8-mediated gene therapeutic correction. The most significant difference in ureagenesis was at 30min after injection in untreated spf ash mice under fasting conditions (19% of wild-type). Five consecutive injections over a period of five weeks had no effect on body weight or ureagenesis. This method is simple, robust and with no apparent risk, offering a sensitive, minimal-invasive, and fast measurement of ureagenesis capacity using dried blood spots. The stable isotope-based quantification of ureagenesis can be applied for the efficacy-testing of novel molecular therapies. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Measurement of cerebral blood flow using bolus inhalation of C15O2 and positron emission tomography: description of the method and its comparison with the C15O2 continuous inhalation method

    International Nuclear Information System (INIS)

    Kanno, I.; Lammertsma, A.A.; Heather, J.D.; Gibbs, J.M.; Rhodes, C.G.; Clark, J.C.; Jones, T.

    1984-01-01

    This article describes a rapid method for the regional measurement of cerebral blood flow using a single breath of C 15 O 2 and positron emission tomography. The technique is based on the bolus distribution principle and utilises a reference table for the calculation of flow. Seven subjects were studied using both this method and the C 15 O 2 continuous inhalation steady-state technique. The single-breath method gave flow values 20% higher than those obtained using the steady-state method. A simulation study was performed in an attempt to define the reasons for the difference between the two techniques. Estimations were made of identified sources of error in the measurement of regional cerebral blood flow using the single-breath technique and compared with results from a similar study previously described for the steady-state technique. However, further comparative studies will be necessary to satisfactorily explain the difference between both techniques

  2. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  3. A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors

    Directory of Open Access Journals (Sweden)

    Maik Pflugradt

    2017-01-01

    Full Text Available Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG. Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations’ vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway.

  4. A Fast Multimodal Ectopic Beat Detection Method Applied for Blood Pressure Estimation Based on Pulse Wave Velocity Measurements in Wearable Sensors

    Science.gov (United States)

    Pflugradt, Maik; Geissdoerfer, Kai; Goernig, Matthias; Orglmeister, Reinhold

    2017-01-01

    Automatic detection of ectopic beats has become a thoroughly researched topic, with literature providing manifold proposals typically incorporating morphological analysis of the electrocardiogram (ECG). Although being well understood, its utilization is often neglected, especially in practical monitoring situations like online evaluation of signals acquired in wearable sensors. Continuous blood pressure estimation based on pulse wave velocity considerations is a prominent example, which depends on careful fiducial point extraction and is therefore seriously affected during periods of increased occurring extrasystoles. In the scope of this work, a novel ectopic beat discriminator with low computational complexity has been developed, which takes advantage of multimodal features derived from ECG and pulse wave relating measurements, thereby providing additional information on the underlying cardiac activity. Moreover, the blood pressure estimations’ vulnerability towards ectopic beats is closely examined on records drawn from the Physionet database as well as signals recorded in a small field study conducted in a geriatric facility for the elderly. It turns out that a reliable extrasystole identification is essential to unsupervised blood pressure estimation, having a significant impact on the overall accuracy. The proposed method further convinces by its applicability to battery driven hardware systems with limited processing power and is a favorable choice when access to multimodal signal features is given anyway. PMID:28098831

  5. Blood volume measurements in gopher snakes, using autologous 51Cr-labeled red blood cells.

    Science.gov (United States)

    Smeller, J M; Bush, M; Seal, U S

    1978-02-01

    Blood volume determinations were performed in 5 anesthetized gopher snakes (Pituophis melanoleucus catenifer) by means of a 51Cr-labeled red blood cell (RBC) method. The mean blood volume was 52.8 ml/kg of body weight (+/- 6.21 SE). Previous blood volume measurements have not been reported for this species. The RBC survival rate was estimated to be greater than 660 days. The RBC survival rate is long, but it cannot be determined accurately by this method.

  6. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation......Standard diabetes insulin therapy for type 1 diabetes and late stages of type 2 is based on the expected development of blood glucose (BG) both as a consequence of the metabolic glucose consumption as well as of meals and exogenous insulin intake. Traditionally, this is not done explicitly......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  7. [Measurement of blood pressure variability and the clinical value].

    Science.gov (United States)

    Kékes, Ede; Kiss, István

    2014-10-19

    Authors have collected and analyzed literature data on blood pressure variability. They present the methods of blood pressure variability measurement, clinical value and relationships with target organ damages and risk of presence of cardiovascular events. They collect data about the prognostic value of blood pressure variability and the effects of different antihypertensive drugs on blood pressure variability. They underline that in addition to reduction of blood pressure to target value, it is essential to influence blood pressure fluctuation and decrease blood pressure variability, because blood pressure fluctuation presents a major threat for the hypertensive subjects. Data from national studies are also presented. They welcome that measurement of blood pressure variability has been included in international guidelines.

  8. Development of a new Xe-133 single dose multi-step method (SDMM) for muscle blood flow measurement using gamma camera

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Seto, Mikito; Taki, Junichi

    1985-01-01

    In order to measure the muscle blood flow (MBF) during exercise (Ex), a new Xe-133 single dose multi-step method (SDMM) for leg MBF measurement before, during and after Ex using gamma camera was developped. Theoretically, if the activity of Xe-133 in the muscle immediately before and after Ex are known, then the mean MBF during Ex can be calculated. In SDMM, these activities are corrected through correction formula using time delays between end of data aquisition (DA) at rest (R1) and begining of the Ex (TAB), and between end of Ex and begining of the DA after Ex (R2) (TDA). Validity of the SDMM and MBF response on mild and heavy Ex were evaluated in 11 normal volunteers. Ex MBF calculated from 5 and 2.5 min DA (5 sec/frame) both at R1 and R2 were highly correlated (r=.996). Ex MBF by SDMM and direct(measurement by fixed leg exercise were also highly correlated (r=.999). Reproducibility of the R1 and Ex MBF were excellent (r=.999). The highest MBF was seen in GCM on miled walking Ex and in VLM on heavy squatting Ex. After miled Ex, MBF rapidly returned to normal. After heavy Ex, MBF remaind high in VLM In conclusion, SDMM is simple and accurate method for evaluation of dynamic MBF response according to exercise. SDMM is also applicable to the field of sports medicine. (author)

  9. Study on the Measurement of 51Cr-tagged Red Cell Survival: Reevaluation of its method and the effect of Blood loss on red cell survival with 51Cr

    International Nuclear Information System (INIS)

    Choi, Hak Yong; Koh, Chang Soon; Lee, Moon Ho

    1970-01-01

    Reappraisal measurement of apparent half survival time of red cell by 51 Cr method was made and effects of blood-letting over red cell survival were observed. The study was performed on 53 normal male subjects under three different experimental conditions. 1) Group 1: Mean 51 Cr red cell half survival by ACD wash method was 29.7 days. T 1 /2 of Ascorbic acid method was 29.0 days in group with 100 mg dose and 29.1 days in group with 50 mg dose respectively. There was no difference between these two methods in regards to red cell half survival. No difference were noted in amount of ascorbic acid administered. 2) Group 2: As daily amount of blood loss in increased the shortening of red cell half survival was noted. Rapid phase was seen when blood loss ranged 10 to 25 ml per day, while slow phase noted when more loss amounted 25 ml more daily. Thus, it was clear that there was more than an exponential relation between T 1 /2 and the amount of blood loss. 3) Group 3: T 1 /2 measured cpm per whole blood was within normal range and T 1 /2 measured by cpm per red mass showed shortening tendency when compared with the former in the group measured after blood loss (from 25 ml daily up to 100 ml daily in 10 days). In the group with rather constant blood loss of 100 ml daily for 10 consecutive days revealed the significant difference in two measurement (P 1 /2 in non-steady state. When red cell production is increased compared with red cell destruction, T 1 /2 measured by cpm per red cell mass shorter than that by cpm per whole blood. Shortening of T 1 /2 measured by cpm per whole blood is more prominent, if red destruction is enhanced and exceeds production. 5) It is clear that when expressing red cell destruction rate, T 1 /2 measured by cpm per whole blood is more adequate and production more consistent with cpm red cell mass. 6) T 1 /2 measured during blood-letting, when corrected by amount of blood loss, it remains normal. It is erroneous to use conventional equational

  10. Measurement of absolute bone blood flow by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, C.; Cockshott, W.P.; Garnett, E.S.; Belbeck, L.W.

    1986-03-01

    A method of measuring bone blood flow has been developed using /sup 18/F sodium fluoride and positron emission tomography. The blood flow levels are in line with those obtained experimentally from microsphere embolisation. This investigative method could be applied to elucidate a number of clinical questions involving bone perfusion.

  11. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación

    OpenAIRE

    Lynnette Neufeld; Armando García-Guerra; Domingo Sánchez-Francia; Oscar Newton-Sánchez; María Dolores Ramírez-Villalobos; Juan Rivera-Dommarco

    2002-01-01

    Objective. To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Mo...

  12. Noise-Measuring Method

    DEFF Research Database (Denmark)

    Diamond, J. M.

    1965-01-01

    A noise-measuring method based on the use of a calibrated noise generator and an output meter with a special scale is described. The method eliminates the effect of noise contributions occurring in the circuits following the device under test.......A noise-measuring method based on the use of a calibrated noise generator and an output meter with a special scale is described. The method eliminates the effect of noise contributions occurring in the circuits following the device under test....

  13. Invasive v. non-invasive blood pressure measurements the ...

    African Journals Online (AJOL)

    A reasonable correlation exists between invasive and noninvasive methods of measuring systemic blood pressure. However, there are frequent individual differences between these methods and these variations have often caused the validity of the non-invasive measurement to be questioned. The hypothesis that certain ...

  14. Validation of the 133Xe inhalation method for measuring brain stem and cerebellar blood flow in human subjects and the baboon

    International Nuclear Information System (INIS)

    Sakai, F.; Meyer, J. St.; Yamaguchi, F.; Yamamoto, M.; Shaw, T.; Juge, O.

    1979-01-01

    Regional cerebral blood flow (rCBF) measurements recorded by probes placed over the posterior fossa after 133 Xe inhalation have been validated here in. After inhalation, 133 Xe gas is distributed via arterial blood of both carotid an vertebrobasilar systems, so that it should be possible to measure rCBF of the brain stem and cerebellum if appropriate collimation, probe placement and selection of activity are employed. Detectors placed over the suboccipital regions may be subject to distortion by radioactivity derived from extracerebral sources so that the following questions were asked: 1) What is the counting geometry for each probe looking at this area 2) What is the extent of contamination from surrounding tissues 3) Are the flow values reproducible and in accordance with values obtained by other techniques 4) Are the flow values able to show predictable changes under physiological and pathological conditions Animal and human experiments designed to answer these questions are reported. (Auth.)

  15. Measurement of organ blood flow using tritiated water. II. Uterine blood flow in conscious pregnant ewes

    International Nuclear Information System (INIS)

    Brown, B.W.; Oddy, V.H.; Jones, A.W.

    1982-01-01

    Total uterine blood flow was measured with a tritiated water (TOH) diffusion method and with radioactive microspheres in six, conscious, pregnant ewes. With continuous infusion of TOH, equilibrium between the TOH concentration in utero-ovarian venous blood and arterial blood was attained within 50 min of the start of the infusion. The concentration of TOH in uterine and foetal tissue and in foetal blood water was the same as that in uterine venous water by 40 min; at this time, the concentration of TOH in the water of amniotic and allantoic fluids was 96% of that in uterine venous blood water. Estimates of total uterine blood flow obtained using TOH were highly correlated with those obtained with microspheres and the corresponding mean flow values obtained with the two techniques did not significantly differ. The percentage of the total uterine blood flow passing through arteriovenous anastomoses ranged from 1.4 to 3.3%

  16. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...... of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  17. Pulmonary blood volume measured by RI angiocardiography

    International Nuclear Information System (INIS)

    Ono, Kazuo

    1982-01-01

    RI angiocardiography (RACG) was performed in 81 patients with heart disease without congestive heart failure at the time, and the results were compared between the groups with mitral valve disease and other diseases. Cardiac output (CO) and pulmonary mean transit time (PMTT) were compared with the results from the dye dilution method in the same patients. PMTT directly measured by RACG was also compared with the peak to peak time (P-PT). P-PT was expressed as the distance from the right to the left peak time in radiocardiography (RCG). There were good correlations between the CO and PMTT obtained from the RI method and those of the dye dilution method (r = 0.90, r = 0.84). The ralationship between PMTT and P-PT in mitral valve disease was different from that of other diseases. The average value of PMTT was 5.2 +- 1.0 seconds, and pulmonary blood volume (PBV) was 315 +- 57 ml/m 2 in the control group. The PBV values were markedly increased in patients with mitral stenosis (558 +- 132 ml/m 2 ) and mitral regurgitation (444 +- 119 ml/m 2 ), and were slightly increased in aortic valve disease, congenital shunt disease and cardiomyopathy. The patients with ischemic heart disease had normal PBV. In mitral valve disease, the direct method using PMTT of RACG is more accurate than the presumption method using P-PT of RCG. The determination of PBV by this method is very important to observe hemodynamic states in mitral valve disease. (J.P.N.)

  18. Our experience of blood flow measurements using radioactive tracers

    International Nuclear Information System (INIS)

    Danet, Bernard.

    1974-01-01

    A critical study of blood flow measuring methods is proposed. After a review of the various diffusible and non-diffusible radioactive tracers and the corresponding detector systems, the principles which allow to measure blood flow from the data so obtained, are studied. There is a different principle of flow measurement for each type of tracer. The theory of flow measurement using non-diffusible tracers (human serum albumin labelled with 131 I or sup(99m)Tc, 113 In-labelled siderophiline) and its application to cardiac flow measurement are described first. Then the theory of flow measurement using diffusible tracers ( 133 Xe, 85 Kr) and its application to measurement of blood flow through tissues (muscles and kidney particularly) are described. A personal experience of this various flow measurements is reported. The results obtained, the difficulties encountered and the improvments proposed are developed [fr

  19. Quantitative pixel-wise measurement of myocardial blood flow: the impact of surface coil-related field inhomogeneity and a comparison of methods for its correction.

    Science.gov (United States)

    Miller, Christopher A; Hsu, Li-Yueh; Ta, Allison; Conn, Hannah; Winkler, Susanne; Arai, Andrew E

    2015-02-11

    Surface coil-related field inhomogeneity potentially confounds pixel-wise quantitative analysis of perfusion CMR images. This study assessed the effect of surface coil-related field inhomogeneity on the spatial variation of pixel-wise myocardial blood flow (MBF), and assessed its impact on the ability of MBF quantification to differentiate ischaemic from remote coronary territories. Two surface coil intensity correction (SCIC) techniques were evaluated: 1) a proton density-based technique (PD-SCIC) and; 2) a saturation recovery steady-state free precession-based technique (SSFP-SCIC). 26 subjects (18 with significant CAD and 8 healthy volunteers) underwent stress perfusion CMR using a motion-corrected, saturation recovery SSFP dual-sequence protocol. A proton density (PD)-weighted image was acquired at the beginning of the sequence. Surface coil-related field inhomogeneity was approximated using a third-order surface fit to the PD image or a pre-contrast saturation prepared SSFP image. The estimated intensity bias field was subsequently applied to the image series. Pixel-wise MBF was measured from mid-ventricular stress images using the two SCIC approaches and compared to measurements made without SCIC. MBF heterogeneity in healthy volunteers was higher using SSFP-SCIC (24.8 ± 4.1%) compared to PD-SCIC (20.8 ± 3.0%; p = 0.009), however heterogeneity was significantly lower using either SCIC technique compared to analysis performed without SCIC (36.2 ± 6.3%). In CAD patients, the difference in MBF between remote and ischaemic territories was minimal when analysis was performed without SCIC (0.06 ± 0.91 mL/min/kg), and was substantially lower than with either PD-SCIC (0.50 ± 0.63 mL/min/kg; p = 0.013) or with SSFP-SCIC (0.63 ± 0.89 mL/min/kg; p = 0.005). In 6 patients, MBF quantified without SCIC was artifactually higher in the stenosed coronary territory compared to the remote territory. PD-SCIC and SSFP-SCIC had similar differences in MBF between remote and

  20. Home blood pressure measurement in elderly patients with cognitive impairment: comparison of agreement between relative-measured blood pressure and automated blood pressure measurement.

    Science.gov (United States)

    Plichart, Matthieu; Seux, Marie-Laure; Caillard, Laure; Chaussade, Edouard; Vidal, Jean-Sébastien; Boully, Clémence; Hanon, Olivier

    2013-08-01

    Home blood pressure measurement (HBPM) is recommended by guidelines for hypertension management. However, this method might be difficult to use in elderly individuals with cognitive disorders. Our aim was to assess the agreement and the feasibility of HBPM by a relative as compared with 24-h ambulatory blood pressure monitoring (ABPM) in elderly patients with dementia. Sixty outpatients with dementia aged 75 years and older with office hypertension (≥140/90 mmHg) were subjected successively to HBPM by a trained relative and 24-h ABPM. The order of the two methods was randomized. Current guidelines' thresholds for the diagnosis of hypertension were used. The mean (SD) age of the patients was 80.8 (6.1) years (55% women) and the mean (SD) mini-mental state examination score was 20.1 (6.9). The feasibility of relative-HBPM was very high, with a 97% success rate (defined by ≥12/18 measurements reported). The blood pressure measurements were highly correlated between the two methods (r=0.75 and 0.64 for systolic blood pressure and diastolic blood pressure, respectively; Pmethods for the diagnosis of sustained hypertension and white-coat hypertension was excellent (overall agreement, 92%; κ coefficient, 0.81; 95% CI, 0.61-0.93). Similar results were found for daytime-ABPM. In cognitively impaired elderly patients, HBPM by a relative using an automated device was a good alternative to 24-h ABPM.

  1. Blood monitoring systems and methods thereof

    Science.gov (United States)

    Mir, Jose (Inventor); Zander, Dennis (Inventor)

    2012-01-01

    A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

  2. Randomized Comparison of the Therapeutic Effect of Acupuncture, Massage, and Tachibana-Style-Method on Stiff Shoulders by Measuring Muscle Firmness, VAS, Pulse, and Blood Pressure

    Directory of Open Access Journals (Sweden)

    Kazuhiro Tachibana

    2012-01-01

    Full Text Available To compare the therapeutic efficacy of acupuncture, massage, and Tachibana-Ryojutsu (one of Japanese traditional body balance therapy techniques (SEITAI, on stiff shoulders, the subjects’ muscle firmness, blood pressure, pulse, VAS, and body temperature were measured before and after the treatment. Forty-seven volunteer subjects gave written informed consent to participate in this study. The subjects were randomly divided into three groups to receive acupuncture, massage, or Tachibana-Ryojutsu. Each therapy lasted for 90 seconds. The acupuncture treatment was applied by a retaining-needle at GB-21, massage was conducted softly on the shoulders, and Tachibana-Ryojutsu treated only the muscles and joints from the legs to buttocks without touching the shoulders or backs. The study indicated that the muscle firmness and VAS of the Tachibana-Ryojutsu group decreased significantly in comparison with the acupuncture and massage groups after treatment.

  3. Preventing blood transfusion failures: FMEA, an effective assessment method.

    Science.gov (United States)

    Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza

    2017-06-30

    Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.

  4. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    Background: Pregnant diabetic patients are often required to self- measure their blood pressure in the waiting room before consulta- tion. Currently used blood pressure devices do not guarantee valid measurements when used unsupervised. This could lead to misdi- agnosis and treatment error. The aim...... of this study was to investigate current use of blood pressure self-measurement in the waiting room in order to identify challenges that could influence the resulting data quality. Also, we wanted to investigate the potential for addressing these challenges with e-health and telemedicine technology. Subjects...... and Methods: We observed 81 pregnant diabetics’ ability to correctly self-measure in the waiting room during a 4-week observational descriptive study. Specifically, we investigated the level of patient adherence to six recommendations with which patients are in- structed to comply in order to obtain...

  5. Estimating the measurement uncertainty in forensic blood alcohol analysis.

    Science.gov (United States)

    Gullberg, Rod G

    2012-04-01

    For many reasons, forensic toxicologists are being asked to determine and report their measurement uncertainty in blood alcohol analysis. While understood conceptually, the elements and computations involved in determining measurement uncertainty are generally foreign to most forensic toxicologists. Several established and well-documented methods are available to determine and report the uncertainty in blood alcohol measurement. A straightforward bottom-up approach is presented that includes: (1) specifying the measurand, (2) identifying the major components of uncertainty, (3) quantifying the components, (4) statistically combining the components and (5) reporting the results. A hypothetical example is presented that employs reasonable estimates for forensic blood alcohol analysis assuming headspace gas chromatography. These computations are easily employed in spreadsheet programs as well. Determining and reporting measurement uncertainty is an important element in establishing fitness-for-purpose. Indeed, the demand for such computations and information from the forensic toxicologist will continue to increase.

  6. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    , but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...... by the authors at the workshop but were written afterward which allowed to include the findings and conclusions of the various discussions and of course updates. The chapter "Alternative Frameworks for Personalized Insulin-Glucose Models" by Harald Kirchsteiger et al. asks the question whether more and more...... that focus not on the prediction of exact future blood glucose values, but rather on the prediction of changes in the patients’ blood glucose range. The chapter “Accuracy of BG Meters and CGM Systems: Possible Influence Factors for the Glucose Prediction Based on Tissue Glucose Concentrations” by Guido...

  7. A novel approach to office blood pressure measurement: 30-minute office blood pressure vs daytime ambulatory blood pressure

    NARCIS (Netherlands)

    Wel, M.C. van der; Buunk, I.E.; Weel, C. van; Thien, Th.; Bakx, J.C.

    2011-01-01

    PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared

  8. Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ

    Science.gov (United States)

    Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.

    2017-03-01

    Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.

  9. The measurement of limb blood flow using technetium-labelled red blood cells

    International Nuclear Information System (INIS)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-01-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with 99 Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4+-3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1+-2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain. (author)

  10. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  11. Polynomial analysis of ambulatory blood pressure measurements

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. A.; Cleophas, T. J.; van der Wall, E. E.

    2001-01-01

    In normotensive subjects blood pressures follow a circadian rhythm. A circadian rhythm in hypertensive patients is less well established, and may be clinically important, particularly with rigorous treatments of daytime blood pressures. Polynomial analysis of ambulatory blood pressure monitoring

  12. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  13. Reliability of bedside blood glucose estimating methods in detecting ...

    African Journals Online (AJOL)

    Background: Hypoglycaemia occurs in many disease states common in the tropics. Facilities and skilled manpower required for laboratory blood glucose measurement are not always available in health facilities in developing countries. Objective: The study was carried out to determine the validity of bedside methods of ...

  14. Comparison of high-definition oscillometry -- a non-invasive technology for arterial blood pressure measurement -- with a direct invasive method using radio-telemetry in awake healthy cats.

    Science.gov (United States)

    Martel, Eric; Egner, Beate; Brown, Scott A; King, Jonathan N; Laveissiere, Arnaud; Champeroux, Pascal; Richard, Serge

    2013-12-01

    This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into account all pressure ranges, and with data separated in three sub-groups, low, normal and high ranges of systolic (SBP) and diastolic (DBP) blood pressure. SBP data displayed a mean correlation coefficient of 0.92 ± 0.02 that was reduced for low SBP. The agreement level evaluated from the whole data set was high and slightly reduced for low SBP values. The mean correlation coefficient of DBP was lower than for SBP (ie, 0.81 ± 0.02). The bias for DBP between the two methods was 22.3 ± 1.6 mmHg, suggesting that HDO produced lower values than telemetry. These results suggest that HDO met the validation criteria defined by the American College of Veterinary Internal Medicine consensus panel and provided a faithful measurement of SBP in conscious cats. For DBP, results suggest that HDO tended to underestimate DBP. This finding is clearly inconsistent with the good agreement reported in dogs, but is similar to outcomes achieved in marmosets and cynomolgus monkeys, suggesting that this is not related to HDO but is species related. The data support that the HDO is the first and only validated non-invasive blood pressure device and, as such, it is the only non-invasive reference technique that should be used in future validation studies.

  15. Accurate Blood Flow Measurements: Are Artificial Tracers Necessary?

    Science.gov (United States)

    Poelma, Christian; Kloosterman, Astrid; Hierck, Beerend P.; Westerweel, Jerry

    2012-01-01

    Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case), as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements). These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented. PMID:23028878

  16. Automated measurement of retinal blood vessel tortuosity

    Science.gov (United States)

    Joshi, Vinayak; Reinhardt, Joseph M.; Abramoff, Michael D.

    2010-03-01

    Abnormalities in the vascular pattern of the retina are associated with retinal diseases and are also risk factors for systemic diseases, especially cardiovascular diseases. The three-dimensional retinal vascular pattern is mostly formed congenitally, but is then modified over life, in response to aging, vessel wall dystrophies and long term changes in blood flow and pressure. A characteristic of the vascular pattern that is appreciated by clinicians is vascular tortuosity, i.e. how curved or kinked a blood vessel, either vein or artery, appears along its course. We developed a new quantitative metric for vascular tortuosity, based on the vessel's angle of curvature, length of the curved vessel over its chord length (arc to chord ratio), number of curvature sign changes, and combined these into a unidimensional metric, Tortuosity Index (TI). In comparison to other published methods this method can estimate appropriate TI for vessels with constant curvature sign and vessels with equal arc to chord ratios, as well. We applied this method to a dataset of 15 digital fundus images of 8 patients with Facioscapulohumeral muscular dystrophy (FSHD), and to the other publically available dataset of 60 fundus images of normal cases and patients with hypertensive retinopathy, of which the arterial and venous tortuosities have also been graded by masked experts (ophthalmologists). The method produced exactly the same rank-ordered list of vessel tortuosity (TI) values as obtained by averaging the tortuosity grading given by 3 ophthalmologists for FSHD dataset and a list of TI values with high ranking correlation with the ophthalmologist's grading for the other dataset. Our results show that TI has potential to detect and evaluate abnormal retinal vascular structure in early diagnosis and prognosis of retinopathies.

  17. Dynamic Inertia Measurement Method

    Data.gov (United States)

    National Aeronautics and Space Administration — Critically important inertia measurements are complex and expensive to obtain due to the extensive fixturing and custom instrumentation of conventional techniques....

  18. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  19. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular...... simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50-100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic...... techniques for extracting the desired data and for examining them for evidence of nephron synchronization. Synchronized TGF oscillations were detected in pairs or triplets of nephrons. The amplitude and the frequency of the oscillations changed with time, as did the patterns of synchronization...

  20. Usefulness of measurement of blood flow by RI plethysmography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, Kenji; Ling, Qing Cheng; Mori, Yutaka; Tanaka, Uzuru; Shimada, Takao [Jikei Univ., Tokyo (Japan). School of Medicine

    1997-03-01

    We have developed the RI plethysmography, and have applied it to ordinary clinic diagnosis and the evaluation of treatment. The subjects were 58 cases (39 cases of the obstruction of the peripheral blood circulation: ASO 24 cases, TAO 4 cases and arterial sclerotic change 11 cases; the non-abnormal control was 19 cases). The clinical benefit of this method was evaluated. In the cases with 1 and 2 degrees of Fontaine`s classification and ASO and TAO, the blood flow of legs measured by our method significantly decreased in association with symptoms and angiographic findings. This method is suitable to the determination of angiography and evaluation of the effect of treatment. (author)

  1. Signal quality measures for unsupervised blood pressure measurement

    International Nuclear Information System (INIS)

    Abdul Sukor, J; Redmond, S J; Lovell, N H; Chan, G S H

    2012-01-01

    Accurate systolic and diastolic pressure estimation, using automated blood pressure measurement, is difficult to achieve when the transduced signals are contaminated with noise or interference, such as movement artifact. This study presents an algorithm for automated signal quality assessment in blood pressure measurement by determining the feasibility of accurately detecting systolic and diastolic pressures when corrupted with various levels of movement artifact. The performance of the proposed algorithm is compared to a manually annotated reference scoring (RS). Based on visual representations and audible playback of Korotkoff sounds, the creation of the RS involved two experts identifying sections of the recorded sounds and annotating sections of noise contamination. The experts determined the systolic and diastolic pressure in 100 recorded Korotkoff sound recordings, using a simultaneous electrocardiograph as a reference signal. The recorded Korotkoff sounds were acquired from 25 healthy subjects (16 men and 9 women) with a total of four measurements per subject. Two of these measurements contained purposely induced noise artifact caused by subject movement. Morphological changes in the cuff pressure signal and the width of the Korotkoff pulse were extracted features which were believed to be correlated with the noise presence in the recorded Korotkoff sounds. Verification of reliable Korotkoff pulses was also performed using extracted features from the oscillometric waveform as recorded from the inflatable cuff. The time between an identified noise section and a verified Korotkoff pulse was the key feature used to determine the validity of possible systolic and diastolic pressures in noise contaminated Korotkoff sounds. The performance of the algorithm was assessed based on the ability to: verify if a signal was contaminated with any noise; the accuracy, sensitivity and specificity of this noise classification, and the systolic and diastolic pressure

  2. Method comparison and validation of a prototype device for measurement of ionized calcium concentrations cow-side against a point-of-care instrument and a benchtop blood-gas analyzer reference method.

    Science.gov (United States)

    Neves, R C; Stokol, T; Bach, K D; McArt, J A A

    2018-02-01

    The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POC VS ; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POC VS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POC VS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POC VS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POC VS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POC VS . With heparin-balanced samples under laboratory conditions, the prototype and POC VS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POC VS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from

  3. Accurate Blood Flow Measurements : Are Artificial Tracers Necessary?

    NARCIS (Netherlands)

    Poelma, C.; Kloosterman, A.; Hierck, B.P.; Westerweel, J.

    2012-01-01

    Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies

  4. [An integrated system of blood pressure measurement with bluetooth communication].

    Science.gov (United States)

    Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu

    2012-07-01

    The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.

  5. Determination of blood circulation in oral formations using Rb86 distribution method and labelled micropearl method

    International Nuclear Information System (INIS)

    Fazekas, A.; Posch, E.; Harsing, L.

    1979-01-01

    The blood circulation of incisors, dental pulp and tongue was detemined using the measurement of 86 Rb distribution in rats. The results were compared with those obtained by a simultaneous micropearl method. It was found that 37 per cent of 86 Rb in dental tissues is localized in the hard propiodentium, with a high proportion diffusing from the periodontium. The 86 Rb fraction localized in the tongue represents its blood circulation. (author)

  6. Assessing blood flow control through a bootstrap method

    OpenAIRE

    Simpson, D.M.; Panerai, R.B.; Ramos, E.G.; Lopes, J.M.A.; Villar Marinatto, M.N.; Nadal, J.; Evans, D.H.

    2004-01-01

    In order to assess blood flow control, the relationship between blood pressure and blood flow can be modeled by linear filters. We present a bootstrap method, which allows the statistical analysis of an index of blood flow control that is obtained from constrained system identification using an established set of pre-defined filters.

  7. Chronic intestinal ischaemia: measurement of the total splanchnic blood flow.

    Science.gov (United States)

    Zacho, Helle D

    2013-04-01

    A redundant collateral network between the intestinal arteries is present at all times. In case of ischaemia in the gastrointestinal tract, the collateral blood supply can develop further, thus accommodating the demand for oxygen even in the presence of significant stenosis or occlusion of the intestinal arteries without clinical symptoms of intestinal ischaemia. Symptoms of ischemia develop when the genuine and collateral blood supply no longer can accommodate the need for oxygen. Atherosclerosis is the most common cause of obliteration in the intestinal arteries. In chronic intestinal ischaemia (CII), the fasting splanchnic blood flow (SBF) is sufficient, but the postprandial increase in SBF is inadequate and abdominal pain will therefore develop in relation to food intake causing the patient to eat smaller meals at larger intervals with a resulting weight loss. Traditionally, the CII-diagnosis has exclusively been based upon morphology (angiography) of the intestinal arteries; however, substantial discrepancies between CII-symptoms and the presence of atherosclerosis/stenosis in the intestinal arteries have been described repeatedly in the literature impeding the diagnosis of CII. This PhD thesis explores a method to determine the total SBF and its potential use as a diagnostic tool in patients suspected to suffer from CII. The SBF can be measured using a continuous infusion of a tracer and catheterisation of a hepatic vein and an artery. By measuring the SBF before and after a standard meal it is possible to assess the ability or inability to enhance the SBF and thereby diagnosing CII. In Study I, measurement of SBF was tested against angiography in a group of patients suspected to suffer from CII due to pain and weight loss. A very good agreement between the postprandial increase in SBF and angiography was found. The method was validated against a well-established method independent of the hepatic extraction of tracer using pAH in a porcine model (study II

  8. The comparison of placental removal methods on operative blood loss

    International Nuclear Information System (INIS)

    Waqar, F.; Fawad, A.

    2008-01-01

    On an average 1 litre of blood is lost during Caesarean Section. Many variable techniques have been tried to reduce this blood loss. Many study trials have shown the spontaneous delivery of placenta method to be superior over manual method because of reduced intra operative blood loss and reduced incidence of post operative endometritis. The main objective of our study was to compare the risk of blood loss associated with spontaneous and manual removal of the placenta during caesarean section. This study was conducted at Department of Obstetrics and Gynaecology, Islamic International Medical Complex, Islamabad from September 2004 to September 2005. All Women undergoing elective or emergency caesarean section were included in the study. Exclusion criteria were pregnancy below 37 weeks, severe maternal anaemia, and prolonged rupture of the membranes with fever, placenta praevia, placenta accreta and clotting disorders. Patients were allocated to the two groups randomly. Group A comprised of women in whom the obstetrician waited a maximum of 5 minutes till the placenta delivered spontaneously. In group B the obstetrician manually cleaved out the placenta as soon as the infant was delivered. The primary outcome measures noted were difference in haemoglobin of >2 gm/dl (preoperatively and postoperatively), time interval between delivery of baby and placenta, significant blood loss (>1000 cc), additional use of oxytocics, total operating time and blood transfusions. Data was analysed by SPSS. Statistical tests used for specific comparison were chi square-test and Student's t-test. One hundred and forty-five patients were allocated to two groups randomly. Seventy-eight patients were allocated to group A and 67 patients allocated to group B. Mean maternal age, birth weight, and total operating time were the same in two groups, but blood loss as measured by a difference in haemoglobin of greater then 2 grams/dl was statistically significant. Significant blood loss (>1000 cc

  9. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...

  10. Prospective blood pressure measurement in renal transplant recipients.

    Science.gov (United States)

    David, V G; Yadav, B; Jeyaseelan, L; Deborah, M N; Jacob, S; Alexander, S; Varughese, S; John, G T

    2014-05-01

    Blood pressure (BP) control at home is difficult when managed only with office blood pressure monitoring (OBPM). In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM) was compared with ambulatory blood pressure monitoring (ABPM) as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2(nd), 4(th), 6(th), and 9(th) months and all the three methods: OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%). Systolic BP (SBP) and diastolic BP (DBP) measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa: 0.88 vs. 89% specificity, Kappa: 0.71). HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa: 0.71 vs. 50% specificity Kappa: 0.54). In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  11. Prospective blood pressure measurement in renal transplant recipients

    Directory of Open Access Journals (Sweden)

    V G David

    2014-01-01

    Full Text Available Blood pressure (BP control at home is difficult when managed only with office blood pressure monitoring (OBPM. In this prospective study, the reliability of BP measurements in renal transplant patients with OBPM and home blood pressure monitoring (HBPM was compared with ambulatory blood pressure monitoring (ABPM as the gold standard. Adult patients who had living-related renal transplantation from March 2007 to February 2008 had BP measured by two methods; OBPM and ABPM at pretransplantation, 2 nd , 4 th , 6 th , and 9 th months and all the three methods : OBPM, ABPM, and HBPM at 6 months after transplantation. A total of 49 patients, age 35 ± 11 years, on prednisolone, tacrolimus, and mycophenolate were evaluated. A total of 39 were males (79.6%. Systolic BP (SBP and diastolic BP (DBP measured by OBPM were higher than HBPM when compared with ABPM. When assessed using OBPM and awake ABPM, both SBP and DBP were significantly overestimated by OBPM with mean difference of 3-12 mm Hg by office SBP and 6-8 mm Hg for office DBP. When HBPM was compared with mean ABPM at 6 months both the SBP and DBP were overestimated by and 7 mm Hg respectively. At 6 months post transplantation, when compared with ABPM, OBPM was more specific than HBPM in diagnosing hypertension (98% specificity, Kappa : 0.88 vs. 89% specificity, Kappa : 0.71. HBPM was superior to OBPM in identifying patients achieving goal BP (89% specificity, Kappa : 0.71 vs. 50% specificity Kappa : 0.54. In the absence of a gold standard for comparison the latent class model analysis still showed that ABPM was the best tool for diagnosing hypertension and monitoring patients reaching targeted control. OBPM remains an important tool for the diagnosis and management of hypertension in renal transplant recipients. HBPM and ABPM could be used to achieve BP control.

  12. Epidermal Inorganic Optoelectronics for Blood Oxygen Measurement.

    Science.gov (United States)

    Li, Haicheng; Xu, Yun; Li, Xiaomin; Chen, Ying; Jiang, Yu; Zhang, Changxing; Lu, Bingwei; Wang, Jian; Ma, Yinji; Chen, Yihao; Huang, Yin; Ding, Minquang; Su, Honghong; Song, Guofeng; Luo, Yi; Feng, X

    2017-05-01

    Flexible and stretchable optoelectronics, built-in inorganic semiconductor materials, offer a wide range of unprecedented opportunities and will redefine the conventional rigid optoelectronics in biological application and medical measurement. However, a significant bottleneck lies in the brittleness nature of rigid semiconductor materials and the performance's extreme sensitivity to the light intensity variation due to human skin deformation while measuring physical parameters. In this study, the authors demonstrate a systematic strategy to design an epidermal inorganic optoelectronic device by using specific strain-isolation design, nanodiamond thinning, and hybrid transfer printing. The authors propose all-in-one suspension structure to achieve the stretchability and conformability for surrounding environment, and they propose a two-step transfer printing method for hybrid integrating III-V group emitting elements, Si-based photodetector, and interconnects. Owing to the excellent flexibility and stretchability, such device is totally conformal to skin and keeps the constant light transmission between emitting element and photodetector as well as the signal stability due to skin deformation. This method opens a route for traditional inorganic optoelectronics to achieve flexibility and stretchability and improve the performance of optoelectronics for biomedical application. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. X-ray PIV measurements of blood flows without tracer particles

    International Nuclear Information System (INIS)

    Kim, Guk Bae; Lee, Sang Joon

    2006-01-01

    We analyzed the non-Newtonian flow characteristics of blood moving in a circular tube flow using an X-ray PIV method and compared the experimental results with hemodynamic models. The X-ray PIV method was improved for measuring quantitative velocity fields of blood flows using a coherent synchrotron X-ray. Without using any contrast media, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells. The enhanced X-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit in detail. The quantitative velocity fields of blood flows inside opaque conduits were obtained by applying a two-frame PIV algorithm to the X-ray images of the blood flows. The measured velocity data show typical features of blood flow such as the yield stress and shear-thinning effects. (orig.)

  14. X-ray PIV measurements of blood flows without tracer particles

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Guk Bae; Lee, Sang Joon [Pohang University of Science and Technology, Department of Mechanical Engineering, Pohang (Korea)

    2006-08-15

    We analyzed the non-Newtonian flow characteristics of blood moving in a circular tube flow using an X-ray PIV method and compared the experimental results with hemodynamic models. The X-ray PIV method was improved for measuring quantitative velocity fields of blood flows using a coherent synchrotron X-ray. Without using any contrast media, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells. The enhanced X-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit in detail. The quantitative velocity fields of blood flows inside opaque conduits were obtained by applying a two-frame PIV algorithm to the X-ray images of the blood flows. The measured velocity data show typical features of blood flow such as the yield stress and shear-thinning effects. (orig.)

  15. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Treatment of High Blood Pressure (JNC-7),8 with the subjects sitting quietly and the right arm on a table at the level of the heart. An appropriately sized cuff, covering at least two-thirds of the upper arm with the lower border not less than 2.5 cm from the cubital fossa, was applied after restricting clothing had been removed.

  16. Colour measurement and white blood cell recognition

    CERN Document Server

    Gelsema, E S

    1972-01-01

    As a part of a collaboration with NEMCH aimed at the automation of the differential white blood cell count, studies have been made of the different possibilities for using colour to help in the recognition process. Results are presented comparing data obtained with a microspectrophotometer and with a simulated three-colour scanner.

  17. Measurement of regional cerebral blood flow by positron emission tomography

    International Nuclear Information System (INIS)

    Herscovitch, P.; Powers, W.J.

    1987-01-01

    The principal advantage of positron emission tomography over other methods for measuring cerebral blood flow stems from the accurate, quantitative three-dimensional measurements of regional brain radioactivity that are possible with this technique. As a result, accurate quantitative measurements of regional cerebral blood flow can be obtained for both superficial and deep cerebral structures. The value of PET for investigating central nervous system physiology and pathology extends far beyond this, however. Through the use of different radiotracers and appropriate mathematical models, PET can be applied to the measurement of a wide variety of physiologic variables. Measurements of rCBF tell only part of the story. Experience with PET and with a variety of other techniques has taught us that rCBF is at times a poor indicator of the metabolic, functional, and biochemical status of cerebral tissue. It is only by understanding the interaction of all of these factors that our understanding of neurologic disease can advance. It is in the investigation of these complex relationships that the real value of PET resides

  18. Automated methods of corrosion measurement

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Bech-Nielsen, Gregers; Reeve, John Ch

    1997-01-01

    to revise assumptions regarding the basis of the method, which sometimes leads to the discovery of as-yet unnoticed phenomena. The present selection of automated methods for corrosion measurements is not motivated simply by the fact that a certain measurement can be performed automatically. Automation...

  19. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación

    Directory of Open Access Journals (Sweden)

    Lynnette Neufeld

    2002-06-01

    Full Text Available Objective. To assess the comparability of hemoglobin concentration (Hb in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn and to document the influence of type of blood (capillary or venous and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Results. Capillary blood had higher Hb (+0.5g/dl than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3g/dl. Specificity to detect anemia was adequate (>0.90 but sensitivity was low for capillary blood assessed by Hemocue (Objetivo. Evaluar la comparabilidad de la concentración de hemoglobina (Hb en sangre venosa y capilar medida por Hemocue y por espectrofotómetro automatizado (Celldyn, así como documentar la influencia del tipo de sangre (capilar o venosa y del método de análisis sobre la prevalencia de anemia. Material y métodos. De febrero a mayo de 2000, se recolectaron muestras de sangre capilar y venosa en 72 adultos y niños en el Hospital del Niño Morelense, Cuernavaca, Morelos, México. Se determinaron los niveles de Hb con los métodos Hemocue y Celldyn. Las cifras de Hb estimadas se compararon con el coeficiente de concordancia y la prueba pareada de t de Student. También se comparó la sensibilidad y especificidad para el diagnóstico de anemia, utilizando sangre de los dos tipos y métodos de análisis. Resultados. La Hb fue mayor en sangre capilar comparada con sangre venosa

  20. A radiometric method for estimating blood cholinesterase in the field*

    Science.gov (United States)

    Winteringham, F. P. W.; Disney, R. W.

    1964-01-01

    A radiometric method has been developed which provides for the simple and rapid measurement of human blood cholinesterase under field conditions. The method involves minimal dilution of samples and the use of very low substrate concentrations, and is therefore more sensitive to cholinesterase inhibition by reversible anticholinesterases such as carbamates than the conventional manometric or ΔpH methods. A 20-μl sample of haemolysed whole blood is mixed with 14C-labelled acetylcholine on a cavity microscope slide. After half a minute or three minutes the mixture is acidified and dried. Under these conditions radioactive acetate liberated enzymically is completely volatile while the radioactive unhydrolysed substrate is not. The loss of radioactivity on acidification and drying is therefore a direct measure of the acetylcholinesterase activity. The levels of radioactivity employed are far below those likely to present any significant health hazard or to require special laboratory conditions. Although the method requires a labelled substrate, a single preparation is sufficient for several hundred thousand enzyme assays. The method has been tested under simulated field conditions. PMID:14122430

  1. A Modern Method to Monitor Office Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emiliya Khazan

    2017-10-01

    Full Text Available The diagnosis and management of hypertension relies on accurate and precise blood pressure (BP measurements and monitoring techniques. Variability in traditional office based BP readings can contribute to misclassification and potential misdiagnosis of hypertension, leading to inappropriate treatment and possibly avoidable adverse drug events. Both home blood pressure monitoring (HBPM and 24-hour ambulatory blood pressure monitoring (ABPM can improve characterization of BP status over traditional office values and can predict cardiovascular morbidity and mortality risk; however, they are limited by availability and/or practical use in many situations. Available in-office blood pressure measuring methods include manual auscultation, automated oscillometric, and automated office blood pressure (AOBP devices. A strong correlation exists between AOBP and awake ABPM measurements and has been linked to better prediction of end-organ damage and white coat response compared to standard office BP methods. While AOBP does not provide nocturnal BP readings, it can be utilized in several outpatient settings, and has the capability to decrease utilization of ABPM, white coat effect, and improve optimization of cardiovascular assessment, evaluation, and therapeutic assessment in clinical practice. Hypertension affects over 80 million adults in the United States (US and is a major risk factor for cardiovascular morbidity and mortality [1]. The condition’s ubiquitous nature and broad impact potentially makes understanding the diagnosis and treatment of hypertension key elements of managing cardiovascular risk. Though much attention is paid to the treatment of hypertension, from 2009 to 2012, 45.9% of US patients with hypertension were uncontrolled [1]. Appreciating the aspects of proper assessment of blood pressure is crucial and creates the foundation for approaching hypertension management. Until recently, hypertension was defined as an appropriately

  2. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  3. Cutaneous and subcutaneous blood flow measurements in psoriasis

    International Nuclear Information System (INIS)

    Klemp, P.

    1987-01-01

    The experiments - published in 7 papers in The Journal of Investigative Dermatology 1983-86 - have demonstrated: 1. The accuracy of the local 133 Xe washout method is about 15% for estimation of the cutaneous blood flow (CBF), and about 10% for subcutaneous blood flow measurements (SBF). In measurements of absolute CBF values a graphic curve resolution of the washout curve should alwaus be performed. Otherwise the CBF might be considerably underestimated. 2. CdTe(Cl) mini-detectors can be attached directly to the skin, and might yield measurements of both CBF and SBF that can substitute for those made with conventional detectors. 3. The laser Doppler measurements could not be correlated to quantitative measurements of the CBF. 4. The tissue-to-blood partition coefficient for 133 Xe of lesional psoriatic skin (LS) is increased. 5. In untreated, LS of patients with active psoriasis the CBF is about a factor of 10 times higher than the CBF of normal individuals. In non-lesional skin (NLS) of patients with active psoriasis the CBF is about a factor of 2 higher than the CBF of normal individuals. However, the CBF did not differ in NLS of patients with minimal skin manifestations. The high CBF decreases gradualy during antipsoriatic treatment. 6. A paradoxical autoregulation of the CBF was observed in LS. 7. The high CBF is not due to a maximally dilated vascular bed. 8. The SBF in LS areas was a factor of higher than the SBF in normal individuals. 9. A normal, local regulation of the SBF was found. (author)

  4. Blood viscoelasticity measurement using steady and transient flow controls of blood in a microfluidic analogue of Wheastone-bridge channel

    Science.gov (United States)

    Jun Kang, Yang; Lee, Sang-Joon

    2013-01-01

    Accurate measurement of blood viscoelasticity including viscosity and elasticity is essential in estimating blood flows in arteries, arterials, and capillaries and in investigating sub-lethal damage of RBCs. Furthermore, the blood viscoelasticity could be clinically used as key indices in monitoring patients with cardiovascular diseases. In this study, we propose a new method to simultaneously measure the viscosity and elasticity of blood by simply controlling the steady and transient blood flows in a microfluidic analogue of Wheastone-bridge channel, without fully integrated sensors and labelling operations. The microfluidic device is designed to have two inlets and outlets, two side channels, and one bridge channel connecting the two side channels. Blood and PBS solution are simultaneously delivered into the microfluidic device as test fluid and reference fluid, respectively. Using a fluidic-circuit model for the microfluidic device, the analytical formula is derived by applying the linear viscoelasticity model for rheological representation of blood. First, in the steady blood flow, the relationship between the viscosity of blood and that of PBS solution (μBlood/μPBS) is obtained by monitoring the reverse flows in the bridge channel at a specific flow-rate rate (QPBSSS/QBloodL). Next, in the transient blood flow, a sudden increase in the blood flow-rate induces the transient behaviors of the blood flow in the bridge channel. Here, the elasticity (or characteristic time) of blood can be quantitatively measured by analyzing the dynamic movement of blood in the bridge channel. The regression formula (ABlood (t) = Aα + Aβ exp [−(t − t0)/λBlood]) is selected based on the pressure difference (ΔP = PA − PB) at each junction (A, B) of both side channels. The characteristic time of bloodBlood) is measured by analyzing the area (ABlood) filled with blood in the bridge channel by selecting an appropriate detection window in the

  5. The optimal scheme of self blood pressure measurement as determined from ambulatory blood pressure recordings

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Kessels, Alfons G. H.; Lenders, Jacques W. M.; Thien, Theo; van Montfrans, Gert A.; Smit, Andries J.; de Leeuw, Peter W.

    Objective To determine how many self-measurements of blood pressure (BP) should be taken at home in order to obtain a reliable estimate of a patient's BP. Design Participants performed self blood pressure measurement (SBPM) for 7 days (triplicate morning and evening readings). In all of them, office

  6. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  7. The determination of chromium-50 in human blood and its utilization for blood volume measurements

    International Nuclear Information System (INIS)

    Zeisler, R.; Young, I.

    1986-01-01

    Possible relationships between insufficient blood volume increases during pregnancy and infant mortality could be established with an adequate measurement procedure. An accurate and precise technique for blood volume measurements has been found in the isotope dilution technique using chromium-51 as a label for red blood cells. However, in a study involving pregnant women, only stable isotopes can be used for labeling. Stable chromium-50 can be determined in total blood samples before and after dilution experiments by neutron activation analysis (NAA) or mass spectrometry. However, both techniques may be affected by insufficient sensitivity and contamination problems at the inherently low natural chromium concentrations to be measured in the blood. NAA procedures involving irradiations with highly thermalized neutrons at a fluence rate of 2x10 13 n/cm 2 xs and low background gamma spectrometry are applied to the analysis of total blood. Natural levels of chromium-50 in human and animal blood have been found to be <0.1 ng/mL; i.e., total chromium levels of <3 ng/mL. Based on the NAA procedure, a new approach to the blood volume measurement via chromium-50 isotope dilution has been developed which utilizes the ratio of the induced activities of chromium-51 to the iron-59 in three blood samples taken from each individual, namely blank, labeled and diluted labeled blood. (author)

  8. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...... access blood flow measured before and after every procedure. Two methods, catheter-based thermodilution and Doppler ultrasound, were compared to the reference method of ultrasound dilution. Catheter-based thermodilution and Doppler ultrasound were performed during the endovascular procedures while flow...

  9. Simultaneous measurement of erythrocyte deformability and blood viscoelasticity using micropillars and co-flowing streams under pulsatile blood flows.

    Science.gov (United States)

    Kang, Yang Jun

    2017-01-01

    The biophysical properties of blood provide useful information on the variation in hematological disorders or diseases. In this study, a simultaneous measurement method of RBC (Red Blood Cell) deformability and blood viscoelasticity is proposed by evaluating hemodynamic variations through micropillars and co-flowing streams under sinusoidal blood flow. A disposable microfluidic device is composed of two inlets and two outlets, two upper side channels, and two lower side channels connected to one bridge channel. First, to measure the RBC deformability, the left-lower side channel has a deformability assessment chamber (DAC) with narrow-sized micropillars. Second, to evaluate the blood viscoelasticity in co-flowing streams, a phosphate buffered saline solution is supplied at a constant flow rate. By closing or opening a pinch valve connected to the outlet of DAC, blood flows in forward or back-and-forth mode. A time-resolved micro-particle image velocimetry technique and a digital image processing technique are used to quantify the blood velocity and image intensity. Then, RBC deformability is evaluated by quantifying the blood volume passing through the DAC under forward flow, and quantifying the variations of blood velocity and image intensity in the DAC under back-and-forth flow. Using a discrete circuit model, blood viscoelasticity is obtained by evaluating variations of blood velocity and co-flowing streams. The effect of several factors (period, hematocrit, and base solution) on the performance is quantitatively evaluated. Based on the experimental results, the period of sinusoidal flow and hematocrit are fixed at 30 s and 50%, respectively. As a performance demonstration, the proposed method is employed to detect the homogeneous and heterogeneous blood composed of normal RBCs and hardened RBCs. These experimental results show that the RBC deformability is more effective to detect minor subpopulations of heterogeneous bloods, compared with blood viscoelasticity

  10. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  11. Baroreflex regulation measurement using a noninvasive laser Doppler method

    Science.gov (United States)

    Hast, Jukka T.; Myllylae, Risto A.; Sorvoja, Hannu; Nissilae, Seppo M.

    2001-05-01

    In this study, a noninvasive laser Doppler measurement method based on the self-mixing effect of a diode laser was used to measure baroreflex regulation, which is manifest in the blood pressure signal as a 0.1 Hz sinusoidal variation. The laser Doppler measurement system was used to measure the movement of the right radial artery of ten volunteers. Variation in blood pressure caused by the baroreflex affects the elastic properties of the arterial wall. When diastolic blood pressure increases, the elasticity of the arterial wall decreases, causing the wall to lose some of its movability. This decreased elasticity reveals itself in the Doppler signal such that when the blood pressure increases, the Doppler frequency decreases and vice versa. The results show, that the laser Doppler method can be used to measure baroreflex regulation. Finally, baroreflex regulation in the Doppler signal is approximately in the inverse phase with respect to variation in diastolic blood pressure.

  12. Critical evaluation of blood volume measurements during hemodialysis.

    Science.gov (United States)

    Dasselaar, Judith J; van der Sande, Frank M; Franssen, Casper F M

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relative blood volume changes but not on absolute blood volume. Since blood volume varies with the hydration status, identical reductions of RBV may result in very different absolute blood volumes at the end of HD. Second, RBV changes underestimate the change of total blood volume due to translocation of lower-hematocrit blood from the microcirculation to the central circulation. Third, changes in posture before and during HD, food intake, exercise, and administration of intravenous fluids may influence the validity of the RBV measurement. Fourth, results obtained by various RBV devices show large interdevice differences. Finally, although a fall in blood volume is an important factor in dialysis hypotension, frank dialysis hypotension only occurs when the cardiovascular compensatory mechanisms can no longer compensate for the reduction in blood volume. Therefore, the dialysis staff should not exclusively focus on RBV, but also search for opportunities in the dialysis prescription to facilitate cardiovascular compensatory mechanisms, e.g. by lowering dialysate temperature. In the opinion of the authors, routine RBV monitoring should be used with caution until the major conceptual and methodological problems that are inherent to the indirect RBV estimation are clarified. Copyright © 2012 S. Karger AG, Basel.

  13. Neonatal blood gas sampling methods | Goenka | South African ...

    African Journals Online (AJOL)

    Blood gas sampling is part of everyday practice in the care of babies admitted to the neonatal intensive care unit, particularly for those receiving respiratory support. There is little published guidance that systematically evaluates the different methods of neonatal blood gas sampling, where each method has its individual ...

  14. Novel laser Doppler flowmeter for pulpal blood flow measurements

    Science.gov (United States)

    Zang, De Yu; Millerd, James E.; Wilder-Smith, Petra B. B.; Arrastia-Jitosho, Anna-Marie A.

    1996-04-01

    We have proposed and experimentally demonstrated a new configuration of laser Doppler flowmetry for dental pulpal blood flow measurements. To date, the vitality of a tooth can be determined only by subjective thermal or electric tests, which are of questionable reliability and may induced pain in patient. Non-invasive techniques for determining pulpal vascular reactions to injury, treatment, and medication are in great demand. The laser Doppler flowmetry technique is non-invasive; however, clinical studies have shown that when used to measure pulpal blood flow the conventional back-scattering Doppler method suffers from low signal-to-noise ratio (SNR) and unreliable flux readings rendering it impossible to calibrate. A simplified theoretical model indicates that by using a forward scattered geometry the detected signal has a much higher SNR and can be calibrated. The forward scattered signal is readily detectable due to the fact that teeth are relatively thin organs with moderate optical loss. A preliminary experiment comparing forward scattered detection with conventional back- scattered detection was carried out using an extracted human molar. The results validated the findings of the simple theoretical model and clearly showed the utility of the forward scattering geometry. The back-scattering method had readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth. The forward scattered method had consistent readings (within 10%) that were independent of the sensor position, a signal-to-noise ratio that was at least 5.6 times higher than the back-scattering method, and a linear response to flow rate.

  15. Methodological appraisal of SPECT measurements of cerebral blood volume and cerebral tissue hematocrit. Chapter 25

    International Nuclear Information System (INIS)

    Sakai, Fumihiko

    1988-01-01

    In this communication a critical appraisal is given of the method for measuring cerebral blood volume (CBV) and cerebral hematocrit employing single-photon emission computed tomography (SPECT). 2 refs

  16. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  17. Association between blood pressure, measures of body composition ...

    African Journals Online (AJOL)

    Risk factors for development of cardiovascular disease develop early in life and track into adulthood. This study investigated the relationship between blood pressure (BP) and measures of body composition in adolescents. The study participants were 307 adolescents. Blood pressure (BP) and anthropometric parameters: ...

  18. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total

  19. Optoacoustic measurements of human placenta and umbilical blood oxygenation

    Science.gov (United States)

    Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.

    2016-03-01

    Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.

  20. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  1. Combination of phlebography and sanguinous measurement of venous blood pressure

    International Nuclear Information System (INIS)

    Weber, J.

    1988-01-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described. (orig.) [de

  2. Videodensitometric Methods for Cardiac Output Measurements

    Science.gov (United States)

    Mischi, Massimo; Kalker, Ton; Korsten, Erik

    2003-12-01

    Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.

  3. Videodensitometric Methods for Cardiac Output Measurements

    Directory of Open Access Journals (Sweden)

    Massimo Mischi

    2003-04-01

    Full Text Available Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.

  4. Trial on MR portal blood flow measurement with phase contrast technique

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Togami, Izumi

    1991-01-01

    Portal blood flow measurement is considered to be important for the analysis of hemodynamics in various liver diseases. The Doppler ultrasound method has been used extensively during the past several years for measuring portal blood flow, as a non-invasive method. However, the Doppler ultrasound technique do not allow the portal blood flow to be measured in cases of obesity, with much intestinal gas, and so on. In this study, we attempted to measure the blood flow in the main trunk of portal vein as an application of MR phase contrast technique to the abdominal region. In the flow phantom study, the flow volumes and the velocities measured by phase contrast technique showed a close correlation with those measured by electromagnetic flowmeter. In the clinical study with 10 healthy volunteers, various values of portal blood flow were obtained. Mean portal blood flow could be measured within the measuring time (about 8 minutes) under natural breathing conditions. Phase contrast technique is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  5. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  6. High-speed video capillaroscopy method for imaging and evaluation of moving red blood cells

    Science.gov (United States)

    Gurov, Igor; Volkov, Mikhail; Margaryants, Nikita; Pimenov, Aleksei; Potemkin, Andrey

    2018-05-01

    The video capillaroscopy system with high image recording rate to resolve moving red blood cells with velocity up to 5 mm/s into a capillary is considered. Proposed procedures of the recorded video sequence processing allow evaluating spatial capillary area, capillary diameter and central line with high accuracy and reliability independently on properties of individual capillary. Two-dimensional inter frame procedure is applied to find lateral shift of neighbor images in the blood flow area with moving red blood cells and to measure directly the blood flow velocity along a capillary central line. The developed method opens new opportunities for biomedical diagnostics, particularly, due to long-time continuous monitoring of red blood cells velocity into capillary. Spatio-temporal representation of capillary blood flow is considered. Experimental results of direct measurement of blood flow velocity into separate capillary as well as capillary net are presented and discussed.

  7. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  8. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  9. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  10. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    Science.gov (United States)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  11. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    Science.gov (United States)

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  12. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  13. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  14. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood and Dried Blood Spot Samples

    Directory of Open Access Journals (Sweden)

    Stuart A Batterman

    2016-04-01

    Full Text Available The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS. Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs, chlorinated hydrocarbons (CHCs, polychlorinated biphenyls (PCBs, and brominated diphenyl ethers (PBDEs. Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models.Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R2 > 0.80, and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  15. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    Science.gov (United States)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  16. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge

    Science.gov (United States)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Saǧlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioǧlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements.

  17. Measurements of vitamin B12 in human blood serum using resonance Raman spectroscopy

    Science.gov (United States)

    Tsiminis, G.; Schartner, E. P.; Brooks, J. L.; Hutchinson, M. R.

    2016-12-01

    Vitamin B12 (cobalamin and its derivatives) deficiency has been identified as a potential modifiable risk factor for dementia and Alzheimer's disease. Chronic deficiency of vitamin B12 has been significantly associated with an increased risk of cognitive decline. An effective and efficient method for measuring vitamin B12 concentration in human blood would enable ongoing tracking and assessment of this potential modifiable risk factor. In this work we present an optical sensor based on resonance Raman spectroscopy for rapid measurements of vitamin B12 in human blood serum. The measurement takes less than a minute and requires minimum preparation (centrifuging) of the collected blood samples.

  18. Comparative study of red blood cell method in rat and calves blood as alternatives of Draize eye irritation test.

    Science.gov (United States)

    Lagarto, A; Vega, R; Vega, Y; Guerra, I; González, R

    2006-06-01

    Red blood cell assay (RBC) is used to estimate potential irritation of tensioactive agents and detergents. Cell membrane lysis and cell protein denaturation are measured photometrically. This study was aimed to determine if rat blood cells can be used to predict eye potential irritation in the same way of calves blood cells in RBC assay. We evaluated 20 cosmetic formulations using rat and calves blood according to INVITOX protocol No 37. Data of media hemolysis concentration, denaturation index and the ratio of both parameters were compared with in vivo data of eye irritancy. There was a significant difference (ptest. The RBC assay using calves blood showed better results. Several test substances were false negatives with rat blood. This high false negative rate would be correctly identified by the animal test but it may also lead to increased animal consumption. For that RBC assay with calf blood cells is preferable to the employment of rat blood as screening method with a reduction and refinement strategy.

  19. A simplified method for determination of radioactive iron in whole-blood samples

    DEFF Research Database (Denmark)

    Bukhave, Klaus; Sørensen, Anne Dorthe; Hansen, M.

    2001-01-01

    in humans. The overall recovery of radioiron from blood is more than 90%, and the coefficient of variation, as judged by the variation in the ratio Fe-55/Fe-59 is in the order of 4%. Combined with whole-body counting of 59Fe and direct gamma -counting of Fe-59 on blood samples, this method represents......For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method...... for simultaneous determination of Fe-55 and Fe-59 in blood, using a dry-ashing procedure and recrystallization of the remaining iron. The detection Limit of the method permits measurements of 0.1 Bq/ml blood thus allowing detection of Less than 1% absorption from a 40 kBq dose, which is ethically acceptable...

  20. Remote Blood Pressure Waveform Sensing Method and Apparatus

    National Research Council Canada - National Science Library

    Antonelli, Lynn T

    2008-01-01

    The invention as disclosed is a non-contact method and apparatus for continuously monitoring a physiological event in a human or animal, such as blood pressure, which involves utilizing a laser-based...

  1. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography.

    Science.gov (United States)

    Nitzan, Meir; Patron, Amikam; Glik, Zehava; Weiss, Abraham T

    2009-10-26

    Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1) determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2) discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  3. Optimization of ciguatoxin extraction method from blood for Pacific ciguatoxin (P-CTX-1).

    Science.gov (United States)

    Bottein Dechraoui, Marie-Yasmine; Wang, Zhihong; Ramsdell, John S

    2007-01-01

    Ciguatera diagnosis relies on clinical observations associated with a recent consumption of fish. Although needed, direct confirmation of exposure in subjects showing ciguatera disease symptoms is currently unavailable. We previously reported that ciguatoxins were measurable in the blood of mice exposed to extracts of Pacific ciguatoxins isolated from Gambierdiscus polynesiensis, and of Indian Ocean or Caribbean Sea ciguatoxins, isolated from fish. Although highly efficient for extracting spiked purified Caribbean-CTX-1, the methanolic extraction method previously described is found here to yield only 6% recovery of spiked Pacific-CTX-1 (P-CTX-1). We report in this short communication a substantially modified method for ciguatoxin extraction from both dried and fresh blood. With this method, toxin measurement is directly accomplished in acetonitrile deproteinated whole fresh blood or phosphate buffer solution (PBS) eluted dried blood using the N2A cell-based assay. Spike studies using increasing concentrations of purified ciguatoxins reveal linear (r2 above 0.87 for all toxins) and overall efficient toxin recoveries (62%, 96%, and 96% from fresh blood and 75%, 90%, and 74% from dried blood, for C-CTX-1, P-CTX-3C, and P-CTX-1, respectively). Comparative blood matrix analysis for P-CTX-1 recovery shows increased recovery of ciguatoxin activity from whole fresh blood than from dried blood, greater by 20% in P-CTX-1 spiked mice blood and by over 85% in P-CTX-1 exposed mouse blood. In conclusion, both Caribbean and Pacific ciguatoxins can be readily extracted from blood using this modified method; however, in the case of P-CTX-1 we find that fresh blood is optimal.

  4. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on

  5. assessment of measures of adiposity that correlate with blood ...

    African Journals Online (AJOL)

    Comparing BMI with dual energy xray absorptiometry. (DXA), an example of direct measurement of total .... (HEM711DLX) blood pressure apparatus on the left arm placed at heart level after 5-minute rest and using ... weight, waist and arm circumferences were obtained. Height was measured without shoes to the nearest.

  6. Assessment of measures of adiposity that correlate with blood ...

    African Journals Online (AJOL)

    Background: Studies differ on which anthropometric measure of adiposity shows good correlation with cardiovascular diseases. In this study, we evaluated the effects of common epidemiological measures of adiposity as a correlate of elevated blood pressure in an African population. Methodology: The study was carried out ...

  7. Results and validity of renal blood flow measurements using Xenon 133

    International Nuclear Information System (INIS)

    Serres, P.; Danet, B.; Guiraud, R.; Durand, D.; Ader, J.L.

    1975-01-01

    The renal blood flow was measured by external recording of the xenon 133 excretion curve. The study involved 45 patients with permanent high blood pressure and 7 transplant patients. The validity of the method was checked on 10 dogs. From the results it seems that the cortical blood flow, its fraction and the mean flow rate are the most representative of the renal haemodynamics parameters, from which may be established the repercussions of blood pressure on kidney vascularisation. Experiments are in progress on animals to check the compartment idea by comparing injections into the renal artery and into various kidney tissues in situ [fr

  8. Novel approach to laser Doppler measurement of pulpal blood flow

    Science.gov (United States)

    Zang, De Yu; Wilder-Smith, Petra B.; Millerd, James E.; Arrastia-Jitosho, Anna-Marie A.

    1997-07-01

    A modified laser Doppler flowmetry technique that significantly improves the performance of the current technique in measuring pulpal blood flow is described. A preliminary model demonstrates that, by using a forward- scattering geometry, the detected signal will have a much higher signal-to-noise ratio and calibration capacity. The forward-scattered signal is readily detectable because teeth are relatively thin organs with moderate optical loss. Preliminary experiments comparing forward-scattered detection with conventional back-scattered detection were carried out using an extracted, perfused human molar. The results showed that: (1) the existing back-scattering method produced readings that fluctuated by as much as 187% in response to small changes in sensor position relative to the tooth and (2) the forward-scattered method produced consistent readings (within 10%) that were independent of the sensor position, a signal-to-noise ratio that was at least 5.6 times higher than that obtained by the back- scattering method, and a linear response to flow rate. The results validated the findings of the preliminary model and clearly showed the superiority of the forward-scattering geometry.

  9. Blood pressure measurement in epidemiological investigations in teenagers

    International Nuclear Information System (INIS)

    Coppieters, Yves; Parent, Florence; Berghmans, Luc; Godin, Isabelle; Leveque, Alain

    2001-01-01

    Background: The use of sphygmomanometers may lead to problems in investigations on health of young people. The purpose of this paper is to present the validation of the blood pressure (BP) collected during the survey 'Youth Heart Health' in Hainaut by using second sample of young people in Hainaut for which BP was measured by a manual taking of tension and by an electronic device. Methods: Validation was done with a control sample of 343 young with five successive BP measures: twice with the mercury sphygmomanometer and three with DXL. We compared the manual and the electronic measures in order to study the correlation between the two methods. The control sample was used in order to compare the BP measurements with the results of the survey on the health of young people in Hainaut. Results: The differences between manual systolic BP and Dinamap measures are significant (differences in averages 3.6 mmHg; d.s. 7.8; 95% CI: 2.8-4.4 mmHg; p < 0.001) and the regression coefficient is -0.015. Diastolic BP is significantly higher with the manual method than with Dinamap (differences in means: 8.2 mmHg; d.s. 7.0; 95% CI: 7.4-8.9 mmHg; p < 0.001) and the coefficient of regression is 0.096. We observe a difference in BP between the general survey and the control group (10.3 mmHg for systolic manual control and of 10.9 mmHg for systolic electronic control; 3.3 mmHg for diastolic manual control and of 11.5 mmHg for diastolic electronic control). Conclusions: The values of BP of the 'Youth Heart Health' are significantly higher. These observations indicate the difficulties in the choice of the tool for measurements of BP in epidemiological investigations in the teenagers. In order to decrease skews of observations in the measurement of BP, it is recommended to use a valid electronic instrument. Dinamap XL is an instrument of choice in such studies of young people. Environmental and organisational factors may also explain the observed difference, which means that survey

  10. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  11. An online identity authentication method for blood smear

    Directory of Open Access Journals (Sweden)

    Xiaozhen Feng

    2016-11-01

    Full Text Available Blood smear test is the basic method of blood cytology and is also a standard medical test that can help diagnose various conditions and diseases. Morphological examination is the gold standard to determine pathological changes in blood cell morphology. In the biology and medicine automation trend, blood smears' automated management and analysis is very necessary. An online blood smear automatic microscopic image detection system has been constructed. It includes an online blood smear automatic producing part and a blood smear automatic microscopic image detection part. Online identity authentication is at the core of the system. The identifiers printed online always present dot matrix digit code (DMDC whose stroke is not continuous. Considering the particularities of DMDC and the complexities of online application environment, an online identity authentication method for blood smear with heterological theory is proposed. By synthesizing the certain regional features according to the heterological theory, high identification accuracy and high speed have been guaranteed with few features required. In the experiment, the sufficient correct matches between the tube barcode and the identification result verified its feasibility and validity.

  12. Cardiovascular Risk in Hypertension in Relation to Achieved Blood Pressure Using Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G; Kaczorowski, Janusz; Dolovich, Lisa; Tu, Karen; Paterson, J Michael

    2016-10-01

    The SPRINT (Systolic Blood Pressure Intervention Trial) reported that some older, higher risk patients might benefit from a target systolic blood pressure (BP) of <120 versus <140 mm Hg. However, it is not yet known how the BP target and measurement methods used in SPRINT relate to cardiovascular outcomes in real-world practice. SPRINT used the automated office BP technique, which requires the patient to be resting quietly and alone, with multiple readings being recorded automatically using an electronic oscillometric sphygmomanometer. We studied the relationship between achieved automated office BP at baseline and cardiovascular events in 6183 community-dwelling residents of Ontario aged ≥66 years who were receiving antihypertensive therapy and followed for a mean of 4.6 years. Adjusted hazard ratios (95% confidence intervals) were computed for 10 mm Hg increments in achieved automated office BP at baseline using Cox proportional hazards regression and the BP category with the lowest event rate as the reference category. Based on 904 fatal and nonfatal cardiovascular events, the nadir of cardiovascular events was at the systolic pressure category of 110 to 119 mm Hg, which was lower than the next highest category of 120 to 129 mm Hg (hazard ratio 1.30 [1.01, 1.66]). The hazard ratio for diastolic pressure was relatively unchanged above 60 mm Hg. Pulse pressure exhibited an increase in hazard ratio (1.33 [1.02, 1.72]) at ≥80 mm Hg. These results using automated office BP measurement in a usual treatment setting extend the finding in SPRINT of an optimum target systolic BP of <120 mm Hg to routine clinical practice. © 2016 American Heart Association, Inc.

  13. Noninvasive measurement of blood flow and extraction fraction

    International Nuclear Information System (INIS)

    Peters, A.M.; Gunasekera, R.D.; Henderson, B.L.; Brown, J.; Lavender, J.P.; De Souza, M.; Ash, J.M.; Gilday, D.L.

    1987-01-01

    We describe the theory of a technique for the noninvasive measurement of organ blood flow which is based on the principle of fractionation of cardiac output and is applicable with any recirculating gamma emitting tracer. The technique effectively determines the count rate that would be recorded over the organ if the tracer behaved like radiolabelled microspheres and was completely trapped in the organ's vascular bed on first pass. After correction for organ depth, the estimated first pass activity plateau, expressed as a fraction of the injected dose is equal to the organ's fraction of the cardiac output (CO). By extending the theory, organ extraction fraction of extractable tracers or mean transit time of nonextractable tracers can be measured. The technique was applied to the measurement of renal blood flow in the native and transplanted kidney, splenic blood flow, the extraction fraction of DTPA by the kidney and of sulphur colloid by the spleen. (author)

  14. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  15. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  16. Automated Methods of Corrosion Measurements

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    Scanning probe microscopy (SPM) techniques rely on computer recordings of interactions between the tip of a minute probe and the surface of the small specimen as a function of position; the measurements are used to depict an image of the atomic-scale surface topography on the computer screen....... Mechanical control, recording, and data processing must therefore be automated to a high level of precision and reliability. These general techniques and the apparatus involved have been described extensively. The automated methods of such high-resolution microscopy coordinated with computerized...... electrochemical measurements as well as elemental analysis look very promising for elucidating corrosion reaction mechanisms. The study of initial surface reactions at the atomic or submicron level is becoming an important field of research in the understanding of corrosion processes. At present, mainly two...

  17. Pulse dye densitometry using indigo carmine is useful for cardiac output measurement, but not for circulating blood volume measurement.

    Science.gov (United States)

    Fujita, Y; Yamamoto, T; Fuse, M; Kobayashi, N; Takeda, S; Aoyagi, T

    2004-08-01

    We evaluated the validity of a newly developed pulse dye densitometer for indigo carmine for measuring cardiac output and circulating blood volume. Measurements of cardiac output and circulating blood volume were performed with the indigo carmine densitometer during normovolaemia, hypovolaemia and hypervolaemia in nine mongrel dogs under general anaesthesia. The validity was evaluated by comparison of the values of cardiac output and circulating blood volume obtained by the thermodilution technique and the 51Cr-labelled red blood cell method, respectively. We also examined indigo carmine removal by continuous veno-venous haemofiltration after indigo carmine injection. There was good agreement between dye densitometer- and thermodilution-derived cardiac output (r = 0.885, P dye-densitometer-derived circulating blood volume was greater than that of the 51Cr-labelled red blood cell method, and both values showed weak agreement (r = 0.587, P indigo carmine through continuous veno-venous haemofiltration was 0.34+/-0.06. These data indicate that indigo carmine densitometry is a reliable method for cardiac output determination, but it overestimates circulating blood volume, probably due to the transition of indigo carmine into the extravascular space in the systemic circulation.

  18. Measurement of endotoxin levels in blood of hemodialysis Patients by 'Lal' test and comparision of its efficacy with blood culture

    Directory of Open Access Journals (Sweden)

    Gh Vazirzadeh

    2006-01-01

    Full Text Available Introduction: Presently, bacteremia is the principal cause of morbidity in patients undergoing hemodialysis. Gram-negative bacteria account for approximately 50 percent of documented infections. Endotoxins released during lysis of gram negative bacteremia result in inflammatory and defense response by the body and if not treated promptly result in septic shock and ultimately death of the patient. This study describes the detection of endotoxins in blood of patients with bacteremia due to gram - negative bacteria by LAL test. Method: Blood samples of 278 hemodialysis patients were analyzed in this study and pathogens were isolated from blood culture samples. Then, their antibiotic sensitivity was determined. In patients with positive blood culture, endotoxin levels were measured by LAL-test. Results: Frequency of bacteremia in patients was 13.6% . The prevalence of gram – negative bacteremia was 44.7%. E coli were the major pathogens, while staphylococcus aureus was the most common gram positive bacterium. Endotoxin was detected in 15 patients (3.8 ± 1.08 EU/ml . The sensitivity and specificity of endotoxins for gram – negative bacteremia were 88% and 95%, respectively. Conclusion: The results indicate that the LAL method is a fast, sensitive and simple method. There was no significant difference between the results of blood culture and LAL – test ( P > 0.05 .

  19. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...... in conjunction with a mercury-in-Silastic strain gauge for routine measurement of digital blood pressure and blood flow in patients with arterial disease.......A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for use...

  20. A method for estimation of plasma albumin concentration from the buffering properties of whole blood

    DEFF Research Database (Denmark)

    Rees, Stephen Edward; Diemer, Tue; Kristensen, Søren Risom

    2012-01-01

    measurements of acid-base and oxygenation status. This article presents and evaluates a new method for doing so. MATERIALS AND METHODS: The mathematical method for estimating plasma albumin concentration is described. To evaluate the method at numerous albumin concentrations, blood from 19 healthy subjects......PURPOSE: Hypoalbuminemia is strongly associated with poor clinical outcome. Albumin is usually measured at the central laboratory rather than point of care, but in principle, information exists in the buffering properties of whole blood to estimate plasma albumin concentration from point of care...

  1. A new method for detecting hemoglobin directly in whole blood using photon attenuation techniques

    International Nuclear Information System (INIS)

    Medhat, M.E.

    2014-01-01

    The objective of the proposed work is focused on measuring iron concentration directly in whole blood as tool for estimating hemoglobin and anemic conditions in patients across the world. The investigated method depends on theory of photon attenuation through transmission of low energy in whole blood sample. The mathematical expressions for calculating hemoglobin and iron deficit on blood using photon attenuation are derived. Calculations are carried out for estimating concentration of iron in blood samples taken from children, adults and old patients and therefore measuring their hemoglobin and iron deficit from normal values. Theoretical mass attenuation coefficient values were obtained using the XCOM program. A high-resolution gamma-ray spectrometry based on high purity germanium detector was employed to measure attenuation of strongly collimated monoenergetic gamma beam through blood samples. (author)

  2. Measurement of adenosine triphosphate (ATP) content in single red blood cells using the firefly bioluminescent reaction

    Energy Technology Data Exchange (ETDEWEB)

    Kostuk, R.K.; Muhs, A.G.; Kirkpatrick, F.H.; Gabel, C.W.

    1977-01-01

    A unique optical instrument is described which uses the firefly bioluminscent reaction to measure adenosine triphosphate (ATP) levels in single red blood cells. The method allows chemical content level to be associated with individual cell features. The optical instrument consists of a phase contrast microscope to view cells, a pulsed argon-ion laser to rupture the cell membrane, and a photon counting system to measure the bioluminescent yield. The technique has been calibrated against a standard ATP measurement using bulk analysis methods. The ATP loss mechanism for blood cells in a controlled depletion experiment was also investigated.

  3. Bubble measuring instrument and method

    Science.gov (United States)

    Kline-Schoder, Robert (Inventor); Magari, Patrick J. (Inventor)

    2003-01-01

    Method and apparatus are provided for a non-invasive bubble measuring instrument operable for detecting, distinguishing, and counting gaseous embolisms such as bubbles over a selectable range of bubble sizes of interest. A selected measurement volume in which bubbles may be detected is insonified by two distinct frequencies from a pump transducer and an image transducer, respectively. The image transducer frequency is much higher than the pump transducer frequency. The relatively low-frequency pump signal is used to excite bubbles to resonate at a frequency related to their diameter. The image transducer is operated in a pulse-echo mode at a controllable repetition rate that transmits bursts of high-frequency ultrasonic signal to the measurement volume in which bubbles may be detected and then receives the echo. From the echo or received signal, a beat signal related to the repetition rate may be extracted and used to indicate the presence or absence of a resonant bubble. In a preferred embodiment, software control maintains the beat signal at a preselected frequency while varying the pump transducer frequency to excite bubbles of different diameters to resonate depending on the range of bubble diameters selected for investigation.

  4. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  5. Skin blood flow in humans as a function of environmental temperature measured by ultrasound.

    Science.gov (United States)

    Thoresen, M; Walløe, L

    1980-07-01

    We have measured the blood velocities in arteries supplying the skin in humans both in areas with arteriovenous anastomoses (AVA) and in skin areas without AVA in different temperature situations by means of a pulsed, bidirectional doppler ultrasound instrument. The instrument measures the time average of the instantaneous mean of the blood velocities present in a cross-section of a vessel. So long as the cross-sectional area of the vessel is constant, this average velocity is proportional to volume flow. We observe rapid and large fluctuations in blood velocities in arteries supplying skin areas with AVA in a comfortably warm environment. These fluctuations are substantially larger and more rapid than described by previous authors who have used plethysmograph methods. The blood velocities are more constant both at higher and lower environmental temperatures. There are no similar fluctuations in blood velocity in arteries supplying skin areas without AVA.

  6. Measurement of testosterone: how important is a morning blood draw?

    Science.gov (United States)

    Crawford, E David; Poage, Wendy; Nyhuis, Allen; Price, David A; Dowsett, Sherie A; Gelwicks, Steven; Muram, David

    2015-01-01

    Since testosterone levels exhibit a circadian variation with peak levels in the morning, evidence-based guidelines recommend measuring morning total testosterone (TT) levels as the initial diagnostic test for androgen deficiency. However, it has been suggested that morning blood draw may not be necessary in older men due to a blunted circadian rhythm. We sought to determine whether it is possible to expand the morning sampling window for measurement of TT. TT levels were measured in a subset of men (mean age of 61 years) participating in the 2013 Prostate Cancer Awareness Week. TT levels measured in blood drawn from 8 to 11 AM (n = 229) differed significantly from those drawn outside this window (n = 442) (411.7 vs 368.3 ng/dl; p = 0.0003). Differences in TT levels were evident across five blood draw time windows (p = < 0.0001) and persisted after adjustment for age and BMI. TT levels in blood drawn from 2 to 5 PM (344.3 ng/dl) and 5 to 8 PM (334.4 ng/dl) differed significantly from that drawn from 8 to 11 AM (p < 0.05), while TT levels from 11 AM to 2 PM (396.5 ng/dl) and 8 PM to 8 AM (373.4 ng/dl) did not (p = 0.90 and 0.73, respectively). Based on these findings, it may be possible to expand the blood draw time window for measurement of serum TT. This community-based study was not prospectively design to determine the most appropriate blood draw window for TT measurement. Only a single TT measurement was made without consideration for day-to-day variability, and TT levels were not measured in the same men at different blood draw times.

  7. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  8. A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling

    International Nuclear Information System (INIS)

    Iida, Hidehiro; Itoh, Hiroshi; Bloomfield, P.M.; Munaka, Masahiro; Higano, Shuichi; Murakami, Matsutaro; Inugami, Atsushi; Eberl, S.; Aizawa, Yasuo; Kanno, Iwao; Uemura, Kazuo

    1994-01-01

    A method has been developed to quantitate regional cerebral blood blow (rCBF) using iodine-123-labelled N-isopropyl-p-iodoamphetamine (IMP). This technique requires only two single-photon emission tomography (SPET) scans and one blood sample. Based on a two-compartment model, radioactivity concentrations in the brain for each scan time are calculated. A standard input function has been generated by combining the input functions from 12 independent studies prior to this work to avoid frequent arterial blood sampling, and one blood sample is taken at 10 min following IMP administration for calibration of the standard arterial input function. This calibration time was determined such that the integration of the first 40 min of the calibrated, combined input function agreed best with those from 12 individual input functions (the difference was 5.3% on average). This method was applied to eight subjects (two normals and six patients with cerebral infarction), and yielded rCBF values which agreed well with those obtained by a positron emission tomography H 2 15 O autoradiography method. This method was also found to provide rCBF values that were consistent with those obtained by the non-linear least squares fitting technique and those obtained by conventional microsphere model analysis. The optimum SPET scan times were found to be 40 and 180 min for the early and delayed scans, respectively. These scan times allow the use of a conventional rotating gamma camera for clinical purposes. V d values ranged between 10 and 40 ml/g depending on the pathological condition, thereby suggesting the importance of measuring V d for each ROI. In conclusion, optimization of the blood sampling time and the scanning time enabled quantitative measurement of rCBF with two SPET scans and one blood sample. (orig.)

  9. Computational fluid dynamics using in vivo ultrasound blood flow measurements

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian

    2012-01-01

    This paper presents a model environment for construction of patient-specific computational fluid dynamic (CFD) models for the abdominal aorta (AA). Realistic pulsatile velocity waveforms are employed by using in vivo ultrasound blood flow measurements. Ultrasound is suitable for acquisition...

  10. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by pump and was measured at basal before the infusion and 11 s after the start of ... Doppler US is expensive and time consuming,.

  11. Validation of curve-fitting method for blood retention of 99mTc-GSA. Comparison with blood sampling method

    International Nuclear Information System (INIS)

    Ha-Kawa, Sang Kil; Suga, Yutaka; Kouda, Katsuyasu; Ikeda, Koshi; Tanaka, Yoshimasa

    1997-01-01

    We investigated a curve-fitting method for the rate of blood retention of 99m Tc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent 99m Tc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of 99m Tc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1±2.1% (mean±standard deviation, n=77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5±6.1%, n=135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2±11.6%, n=13; vs. 31.9±2.8%, n=7, p 99m Tc-GSA and the plasma retention rate for indocyanine green (r=-0.869, p 99m Tc-GSA and could be a substitute for the blood sampling method. (author)

  12. Correlation of Insulin Resistance with Anthropometric Measures and Blood Pressure in Adolescents

    Science.gov (United States)

    de Morais, Polyana Resende Silva; Sousa, Ana Luiza Lima; Jardim, Thiago de Souza Veiga; Nascente, Flávia Miquetichuc Nogueira; Mendonça, Karla Lorena; Povoa, Thaís Inácio Rolim; Carneiro, Carolina de Souza; Ferreira, Vanessa Roriz; de Souza, Weimar Kunz Sebba Barroso; Jardim, Paulo César Brandão Veiga

    2016-01-01

    Background Blood pressure is directly related to body mass index, and individuals with increased waist circumference have higher risk of developing hypertension, insulin resistance, and other metabolic changes, since adolescence. Objective to evaluate the correlation of blood pressure with insulin resistance, waist circumference and body mass index in adolescents. Methods Cross-section study on a representative sample of adolescent students. One group of adolescents with altered blood pressure detected by casual blood pressure and/or home blood pressure monitoring (blood pressure > 90th percentile) and one group of normotensive adolescents were studied. Body mass index, waist circumference were measured, and fasting glucose and plasma insulin levels were determined, using the HOMA-IR index to identify insulin resistance. Results A total of 162 adolescents (35 with normal blood pressure and 127 with altered blood pressure) were studied; 61% (n = 99) of them were boys and the mean age was 14.9 ± 1.62 years. Thirty-eight (23.5%) adolescents had altered HOMA-IR. The group with altered blood pressure had higher values of waist circumference, body mass index and HOMA-IR (pHOMA-IR than boys (pHOMA-IR in the group with altered blood pressure (ρ = 0.394; p HOMA-IR in both groups (ρ = 0.345; p HOMA-IR was as predictor of altered blood pressure (odds ratio - OR = 2.0; p = 0.001). Conclusion There was a significant association of insulin resistance with blood pressure and the impact of insulin resistance on blood pressure since childhood. The correlation and association between markers of cardiovascular diseases was more pronounced in adolescents with altered blood pressure, suggesting that primary prevention strategies for cardiovascular risk factors should be early implemented in childhood and adolescence. PMID:27007222

  13. Investigation of opportunities of the optical non-invasive diagnostics method for the blood sugar control

    Science.gov (United States)

    Lastovskaia, Elena A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2015-03-01

    The relevance of noninvasive method for determining the blood sugar is caused by necessity of regular monitoring of glucose levels in diabetic patients blood. Traditional invasive method is painful, because it requires a finger pricking. Despite the active studies in the field of non-invasive medical diagnostics, to date the painless and inexpensive instrument for blood sugar control for personal use doesn't exist. It's possible to measure the concentration of glucose in the blood with help of spectrophotometry method. It consists of registering and analyzing the spectral characteristics of the radiation which missed, reflected or absorbed by the object. The authors proposed a measuring scheme for studying the spectral characteristics of the radiation, missed by earlobe. Ultra-violet, visible and near infrared spectral ranges are considered. The paper presents the description of construction and working principles of the proposed special retaining clip and results of experiment with real patient.

  14. Invasively Measured Aortic Systolic Blood Pressure and Office Systolic Blood Pressure in Cardiovascular Risk Assessment

    DEFF Research Database (Denmark)

    Laugesen, Esben; Knudsen, Søren Tang; Hansen, Klavs Würgler

    2016-01-01

    Aortic systolic blood pressure (BP) represents the hemodynamic cardiac and cerebral burden more directly than office systolic BP. Whether invasively measured aortic systolic BP confers additional prognostic value beyond office BP remains debated. In this study, office systolic BP and invasively m...

  15. Measuring retinal blood flow in rats using Doppler optical coherence tomography without knowing eyeball axial length

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenzhong; Yi, Ji; Chen, Siyu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 (United States); Jiao, Shuliang [Department of Biomedical Engineering, Florida International University, Miami, Florida 33174 (United States); Zhang, Hao F., E-mail: hfzhang@northwestern.edu [Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208 and Department of Ophthalmology, Northwestern University, Chicago, Illinois 60611 (United States)

    2015-09-15

    Purpose: Doppler optical coherence tomography (OCT) is widely used for measuring retinal blood flow. Existing Doppler OCT methods require the eyeball axial length, in which empirical values are usually used. However, variations in the axial length can create a bias unaccounted for in the retinal blood flow measurement. The authors plan to develop a Doppler OCT method that can measure the total retinal blood flow rate without requiring the eyeball axial length. Methods: The authors measured the retinal blood flow rate using a dual-ring scanning protocol. The small and large scanning rings entered the eye at different incident angles (small ring: 4°; large ring: 6°), focused on different locations on the retina, and detected the projected velocities/phase shifts along the probing beams. The authors calculated the ratio of the projected velocities between the two rings, and then used this ratio to estimate absolute flow velocity. The authors tested this method in both Intralipid phantoms and in vivo rats. Results: In the Intralipid flow phantom experiments, the preset and measured flow rates were consistent with the coefficient of determination as 0.97. Linear fitting between preset and measured flow rates determined the fitting slope as 1.07 and the intercept as −0.28. In in vivo rat experiments, the measured average total retinal blood flow was 7.02 ± 0.31μl/min among four wild-type rats. The authors’ measured flow rates were consistent with results in the literature. Conclusions: By using a dual-ring scanning protocol with carefully controlled incident angle difference between the two scanning rings in Doppler OCT, the authors demonstrated that it is feasible to measure the absolute retinal blood flow without knowing the eyeball axial length.

  16. 129Xe chemical shift in human blood and pulmonary blood oxygenation measurement in humans using hyperpolarized 129Xe NMR

    Science.gov (United States)

    Norquay, Graham; Leung, General; Stewart, Neil J.; Wolber, Jan

    2016-01-01

    Purpose To evaluate the dependency of the 129Xe‐red blood cell (RBC) chemical shift on blood oxygenation, and to use this relation for noninvasive measurement of pulmonary blood oxygenation in vivo with hyperpolarized 129Xe NMR. Methods Hyperpolarized 129Xe was equilibrated with blood samples of varying oxygenation in vitro, and NMR was performed at 1.5 T and 3 T. Dynamic in vivo NMR during breath hold apnea was performed at 3 T on two healthy volunteers following inhalation of hyperpolarized 129Xe. Results The 129Xe chemical shift in RBCs was found to increase nonlinearly with blood oxygenation at 1.5 T and 3 T. During breath hold apnea, the 129Xe chemical shift in RBCs exhibited a periodic time modulation and showed a net decrease in chemical shift of ∼1 ppm over a 35 s breath hold, corresponding to a decrease of 7–10 % in RBC oxygenation. The 129Xe‐RBC signal amplitude showed a modulation with the same frequency as the 129Xe‐RBC chemical shift. Conclusion The feasibility of using the 129Xe‐RBC chemical shift to measure pulmonary blood oxygenation in vivo has been demonstrated. Correlation between 129Xe‐RBC signal and 129Xe‐RBC chemical shift modulations in the lung warrants further investigation, with the aim to better quantify temporal blood oxygenation changes in the cardiopulmonary vascular circuit. Magn Reson Med 77:1399–1408, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:27062652

  17. A simple technique to measure regional cerebral blood flow during intravascular ballon clamping

    International Nuclear Information System (INIS)

    Furuhata, Shigeru; Kubo, Atsushi; Kawase, Takeshi; Ibata, Yukio; Toya, Shigeo

    1988-01-01

    A case of giant internal carotid ophthalmic aneurysm was presented. In order to clarify whether the patient could tolerate carotid occlusion, a ballon clamping test was performed before surgery. The cerebral blood flow was measured using early imaging by single photon emission computed tomography (SPECT) with N-isopropyl-(iodine-123)-p-iodoamphetamine ( 123 I-IMP). When the ballon clamping test was performed the tracer was injected, and scanning was performed 35 minutes after removing the catheter. This tracer enabled a 'memory of blood flow' during temporary ischemia to determine the character of quick diffusion and slow wash out, that could not be performed by other methods of cerebral blood flow measurement. SPECT with 123 I-IMP can simplify the measurement of cerebral blood flow during the balloon clamping test. (author)

  18. Blood flow and blood volume in the femoral heads of healthy adults according to age. Measurement with positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Kubo, Toshikazu; Kimori, Kokuto; Nakamura, Fuminori; Inoue, Shigehiro; Fujioka, Mikihiro; Ueshima, Keiichiro; Hirasawa, Yasusuke; Ushijima, Yo; Nishimura, Tsunehiko

    2001-01-01

    To deepen understanding of hemodynamics in the femoral head, i.e., the essential factor in clarifying pathogenesis of hip disorders, this study examined blood flow and blood volume in the femoral heads of healthy adults, and their changes with age, by using positron emission tomography (PET). In 16 healthy adult males (age: 20-78 years old, mean age: 42 years), blood flow was measured by means of the H 2 15 O dynamic study method, and blood volume was measured by means of the 15 O-labeled carbon monoxide bolus inhalation method. Blood flow was 1.68-6.47 ml/min/100 g (mean ±SD: 3.52±1.2), and blood volume was 1.67-6.03 ml/100 g (mean ±SD: 3.00±1.27). Blood flow significantly decreased (p<0.01) with age, and blood volume significantly increased (P<0.05). PET was useful in the measurement of blood flow and blood volume in the femoral heads. With age, physiological hemodynamic changes also increased in femoral heads. (author)

  19. Refinement of Telemetry for Measuring Blood Pressure in Conscious Rats

    Science.gov (United States)

    Braga, Valdir A; Prabhakar, Nanduri R

    2009-01-01

    Although considered the ‘gold standard’ for measuring blood pressure in laboratory animals, telemetry would benefit from refinement. In the present study, we tested the hypothesis that the small telemetric device used for blood pressure recording in mice would work for rats as well and would serve as an alternative for those studies where abdominal cavity space is quite limited (such as in young animals and pregnant females). Here we report that the use of a smaller and lighter telemetric device implanted in the abdominal aorta of rats led to acquisition of stable and high-quality blood pressure and heart rate data, similar to those obtained by using a larger telemetric device developed for rats. The use of smaller transmitters represents an alternative telemetry technique, especially for those cases in which space in the abdominal cavity is particularly limited such as during pregnancy. PMID:19476715

  20. Measurement of blood perfusion using photoacoustic, ultrasound, and strain imaging

    Science.gov (United States)

    Mallidi, Srivalleesha; Karpiouk, Andrei B.; Aglyamov, Salavat R.; Sethuraman, Shriram; Emelianov, Stanislav Y.

    2007-02-01

    In many clinical and research applications including cancer diagnosis, tumor response to therapy, reconstructive surgery, monitoring of transplanted tissues and organs, and quantitative evaluation of angiogenesis, sequential and quantitative assessment of microcirculation in tissue is required. In this paper we present an imaging technique capable of spatial and temporal measurements of blood perfusion through microcirculation. To demonstrate the developed imaging technique, studies were conducted using phantoms with modeled small blood vessels of various diameters positioned at different depths. A change in the magnitude of the photoacoustic signal was observed during vessel constriction and subsequent displacement of optically absorbing liquid present in the vessels. The results of the study suggest that photoacoustic, ultrasound and strain imaging could be used to sequentially monitor and qualitatively assess blood perfusion through microcirculation.

  1. Tomographic cerebral blood flow measurement during carotid surgery

    DEFF Research Database (Denmark)

    Rathenborg, Lisbet Knudsen; Vorstrup, Sidsel; Olsen, K S

    1994-01-01

    surgery and performing single photon emission computer tomography (SPECT) scanning shortly after the operation thereby pictures rCBF at the time of injection. DESIGN: Ongoing prospective study. SETTINGS: Departments of Vascular Surgery, Neurology and Anaesthesiology, University Hospital, Rigshospitalet......OBJECTIVES: The aim of the study was to depict regional cerebral blood flow (rCBF) during carotid cross clamping using 99mTechnetium-hexamethylpropylene amine oxime (TcHMPAO). This tracer rapidly passes the blood-brain barrier and is retained for hours in the brain tissue. Injecting TcHMPAO during......, Copenhagen, Denmark. MATERIAL: 15 patients who during a period of 4 months underwent carotid endarterectomy. CHIEF OUTCOME MEASURES: Prior to surgery rCBF was determined using 133Xe and SPECT. Intraoperatively stump pressure was measured and a bolus of TcHMPAO was injected for later SPECT measurement. MAIN...

  2. Nondestructive Measurement of Hemoglobin in Blood Bags Based on Multi-Pathlength VIS-NIR Spectroscopy.

    Science.gov (United States)

    Zhang, Shengzhao; Li, Gang; Wang, Jiexi; Wang, Donggen; Han, Ying; Cao, Hui; Lin, Ling

    2018-02-02

    Hemoglobin concentration is an indicator for assessing blood product quality. To measure hemoglobin concentration in blood products without damaging blood bags, we proposed a method based on visible-near infrared transmission spectroscopy. Complex optical properties of blood bag walls result in measurement irregularities. Analyses showed that the slope of the light intensity-pathlength curve was more robust to the influence of the blood bag wall. In this study, the transmission spectra of red blood cell suspensions at multiple optical pathlengths were obtained, and the slopes of logarithmic light intensity-pathlength curves were calculated through curve fitting. A nondestructive measurement of hemoglobin content was achieved by using a regression model correlating slope spectra and hemoglobin concentration. Sixty samples with hemoglobin concentrations ranging from 72 to 161 g/L were prepared. Among them, 40 samples were used as a calibration set, and the remaining 20 samples were used as a prediction set. The determination coefficient of the prediction set was 0.97, with a mean square error of 2.78 g/L. This result demonstrates that a non-destructive measurement of hemoglobin levels in blood bags can be achieved by multiple-pathlength transmission spectroscopy.

  3. Improved blood velocity measurements with a hybrid image filtering and iterative Radon transform algorithm.

    Science.gov (United States)

    Chhatbar, Pratik Y; Kara, Prakash

    2013-01-01

    Neural activity leads to hemodynamic changes which can be detected by functional magnetic resonance imaging (fMRI). The determination of blood flow changes in individual vessels is an important aspect of understanding these hemodynamic signals. Blood flow can be calculated from the measurements of vessel diameter and blood velocity. When using line-scan imaging, the movement of blood in the vessel leads to streaks in space-time images, where streak angle is a function of the blood velocity. A variety of methods have been proposed to determine blood velocity from such space-time image sequences. Of these, the Radon transform is relatively easy to implement and has fast data processing. However, the precision of the velocity measurements is dependent on the number of Radon transforms performed, which creates a trade-off between the processing speed and measurement precision. In addition, factors like image contrast, imaging depth, image acquisition speed, and movement artifacts especially in large mammals, can potentially lead to data acquisition that results in erroneous velocity measurements. Here we show that pre-processing the data with a Sobel filter and iterative application of Radon transforms address these issues and provide more accurate blood velocity measurements. Improved signal quality of the image as a result of Sobel filtering increases the accuracy and the iterative Radon transform offers both increased precision and an order of magnitude faster implementation of velocity measurements. This algorithm does not use a priori knowledge of angle information and therefore is sensitive to sudden changes in blood flow. It can be applied on any set of space-time images with red blood cell (RBC) streaks, commonly acquired through line-scan imaging or reconstructed from full-frame, time-lapse images of the vasculature.

  4. Validity of a wrist digital monitor for blood pressure measurement in comparison to a mercury sphygmomanometer.

    Science.gov (United States)

    Menezes, Ana M B; Dumith, Samuel C; Noal, Ricardo B; Nunes, Ana Paula; Mendonça, Fernanda I; Araújo, Cora L P; Duval, Marta A; Caruso, Paulo E; Hallal, Pedro C

    2010-03-01

    Valid measurements of blood pressure, both at clinical and community settings, are essential for monitoring this variable at the population level. To evaluate the validity of a wrist digital monitor for measuring blood pressure among adolescents in comparison to a mercury sphygmomanometer. A validation study was carried out in the city of Pelotas, Southern Brazil. Blood pressure was measured twice using two different sphygmomanometers; an OMRON wrist digital and a desktop BD mercury one. Half of the sample was measured first with the digital manometer and subsequently with the mercury one, whereas the remaining half was evaluated in the opposite order. Agreement between both measures was evaluated using the Bland and Altman method. 120 adolescents aged 14 to 15 years were included (50% of each sex). Mean systolic blood pressure among boys was 113.7 mmHg (SD 14.2) when using the mercury manometer and 115.5 mmHg (SD 15.2) when using the digital one. Equivalent values for diastolic blood pressure were 61.5 mmHg (SD 9.9) and 69.6 mmHg (10.2), respectively. Among girls, the mean systolic blood pressure was 104.7 mmHg (SD 10.1) when using the mercury manometer and 102.4 mmHg (SD 11.9) when using the digital device. Values for diastolic blood pressure were 60.0 mmHg (SD 10.4) and 65.7 mmHg (SD 7.7), respectively. The digital device showed a high level of agreement with the mercury manometer when measuring systolic blood pressure. The level of agreement was lower for diastolic blood pressure. The use of correction equations may be an alternative for studies using this wrist digital monitor in adolescent patients.

  5. Automated Methods Of Corrosion Measurements

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; Andersen, Jens Enevold Thaulov; Reeve, John Ch

    1997-01-01

    The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell.......The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell....

  6. Capillary blood sampling from the ear of dogs and cats and use of portable meters to measure glucose concentration.

    Science.gov (United States)

    Wess, G; Reusch, C

    2000-02-01

    Two new methods for collection of capillary blood from the ear of dogs and cats for the measurement of blood glucose concentration using portable blood glucose meters (PBGMs) are described. The first method uses a lancing device after pre-warming the ear, while the second employs a vacuum lancing device. Both methods generated blood drops of adequate size, although the latter method was faster and easier to perform. Accuracy of the two PBGMs was evaluated clinically and statistically. Although assessment of statistical accuracy revealed differences between the PBGMs and the reference method, all of the PBGM readings were within clinically acceptable ranges. Measurement of capillary blood glucose concentration is easy to perform, inexpensive and fast. It may be used by owners to determine blood glucose concentrations at home, and could serve as a new tool for monitoring diabetic dogs and cats.

  7. Reliable blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, C. H.; Rasmussen, Niels H

    2014-01-01

    Background: Patients often fail to adhere to clinical recommendations when using current blood pressure self-measurement (BPSM) methods and equipment. As existing BPSM equipment is not able to detect non-adherent behavior, this could result in misdiagnosis and treatment error. To overcome...... patients scheduled for self-measuring their blood pressure (BP) in the waiting room at an obstetrics department's outpatient clinic to perform an additional BPSM using ValidAid. We then compared the automatically measured and classified values from ValidAid with our manual observations. Results: We found...

  8. Adaptation of atomic spectrometric methods for the determination of trace elements in whole blood and blood fractions

    International Nuclear Information System (INIS)

    Prohaska, C.

    2002-05-01

    Analytical methods were developed and optimized for the determination of the elements Ca, Cr, Cu, Fe, Mg, Mn, Se, V and Zn in whole blood and in the blood fractions plasma, erythrocytes and lymphocytes of a group of people suffering from diabetes and of a control group of healthy individuals. Cr, Mn, Se and V were analyzed by ETAAS. Ca, Cu, Fe, Mg and Zn were analyzed by ICP-OES. The status of trace elements in lymphocytes of people suffering from diabetes is changed. Physiologically interesting correlations were observed between the clinical parameters cholesterol, HDL, LDL, blood glucose, HbA1c, age and BMI and the trace element concentrations, e.g. a correlation of blood glucose and HbA1c with selenium in whole blood. An ETAAS - method for the determination of Co and Mo was developed and optimized. The samples were digested applying a mixture of HNO3 and HF, different types of graphite furnaces were tested and a multiple injection technique was applied, thereby enabling a contribution to the normal values of these elements in human whole blood. An on-line coupling of a LC, controlled by FIA, with an ICP-OES was developed to investigate the concentrations of the iron species Fe(II) and Fe(III) and the copper species Cu(I) and Cu(II) in human blood plasma. The ICP-OES instrument was adapted, batch experiments were carried out, oxidizing and reducing agents were added and the acidity of the eluens, the flow rate and the integration time were optimized. Choosing alanine for complexation of the species of interest enables their separation under physiological conditions. In the real plasma samples measured most of the copper and iron was found in their oxidized forms. (author)

  9. Method of inactivation of viral and bacterial blood contaminants

    International Nuclear Information System (INIS)

    Hackett, R.; Goodrich, R.P.; Van Borssum Waalkes, M.; Wong, V.A.

    1992-01-01

    A method is provided for inactivating viral and/or bacterial contamination in blood cellular matter, such as erythrocytes and platelets, or protein fractions. The cells or protein fractions are mixed with chemical sensitizers and irradiated with, for example, gamma or X-ray radiation

  10. Calibrated delivery drape versus indirect gravimetric technique for the measurement of blood loss after delivery: a randomized trial.

    Science.gov (United States)

    Ambardekar, Shubha; Shochet, Tara; Bracken, Hillary; Coyaji, Kurus; Winikoff, Beverly

    2014-08-15

    Trials of interventions for PPH prevention and treatment rely on different measurement methods for the quantification of blood loss and identification of PPH. This study's objective was to compare measures of blood loss obtained from two different measurement protocols frequently used in studies. Nine hundred women presenting for vaginal delivery were randomized to a direct method (a calibrated delivery drape) or an indirect method (a shallow bedpan placed below the buttocks and weighing the collected blood and blood-soaked gauze/pads). Blood loss was measured from immediately after delivery for at least one hour or until active bleeding stopped. Significantly greater mean blood loss was recorded by the direct than by the indirect measurement technique (253.9 mL and 195.3 mL, respectively; difference = 58.6 mL (95% CI: 31-86); p 500 mL (8.7% vs. 4.7%, p = 0.02). The study suggests a real and significant difference in blood loss measurement between these methods. Research using blood loss measurement as an endpoint needs to be interpreted taking measurement technique into consideration. This study has been registered at clinicaltrials.gov as NCT01885845.

  11. The measurement of blood speed in the pulmonary artery trunk

    International Nuclear Information System (INIS)

    Saro, J.P.; Bula-Cruz, J.; Rafael, J.A.; Botelho, M.F.; Lima, J.P.

    1998-01-01

    The paper describes a non invasive methodology for the measurement of blood speed in the pulmonary artery trunk. The methodology has been tested with a moving radioactive tracer (nuclear medicine). An image processing technique is proposed, for detection and analysis of a moving object with variable shape and intensity over time (radioactive bolus). Experiments on the application of the technique in nuclear medicine are critically analysed. (authors)

  12. Transcutaneous Measurement of Blood Analyte Concentration Using Raman Spectroscopy

    Science.gov (United States)

    Barman, Ishan; Singh, Gajendra P.; Dasari, Ramachandra R.; Feld, Michael S.

    2008-11-01

    Diabetes mellitus is a chronic disorder, affecting nearly 200 million people worldwide. Acute complications, such as hypoglycemia, cardiovascular disease and retinal damage, may occur if the disease is not adequately controlled. As diabetes has no known cure, tight control of glucose levels is critical for the prevention of such complications. Given the necessity for regular monitoring of blood glucose, development of non-invasive glucose detection devices is essential to improve the quality of life in diabetic patients. The commercially available glucose sensors measure the interstitial fluid glucose by electrochemical detection. However, these sensors have severe limitations, primarily related to their invasive nature and lack of stability. This necessitates the development of a truly non-invasive glucose detection technique. NIR Raman Spectroscopy, which combines the substantial penetration depth of NIR light with the excellent chemical specificity of Raman spectroscopy, provides an excellent tool to meet the challenges involved. Additionally, it enables simultaneous determination of multiple blood analytes. Our laboratory has pioneered the use of Raman spectroscopy for blood analytes' detection in biological media. The preliminary success of our non-invasive glucose measurements both in vitro (such as in serum and blood) and in vivo has provided the foundation for the development of feasible clinical systems. However, successful application of this technology still faces a few hurdles, highlighted by the problems of tissue luminescence and selection of appropriate reference concentration. In this article we explore possible avenues to overcome these challenges so that prospective prediction accuracy of blood analytes can be brought to clinically acceptable levels.

  13. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  14. Interscapular brown adipose tissue blood flow in the rat. Determination with 133xenon clearance compared to the microsphere method

    DEFF Research Database (Denmark)

    Astrup, A; Bülow, J; Madsen, J

    1984-01-01

    The xenon clearance method was adapted to continuous measurement of interscapular brown adipose tissue (ISBAT) blood flow in anesthetized rats. The ISBAT-blood partition coefficient for xenon was determined to 3.6 ml X g-1. The blood flow values obtained by Xe clearance were compared with flow...... values obtained concomitantly by the microsphere technique in 17 cold acclimated rats, at ISBAT blood flows between 0.1 and 6 ml X g-1 X min-1. Variations in blood flows were obtained by infusion of noradrenaline at different rates. The blood flow values obtained from the xenon clearance method showed...... a close correlation to the blood flow values determined with microspheres. Y = 0.98. X + 0.15 (r = 0.96, P less than 0.001). The Xe clearance method has the advantages compared to the microsphere technique that it permits continuous monitoring of the blood flow and does not require the sacrifice...

  15. Doppler ultrasound compared with strain gauge for measurement of systolic ankle blood pressure.

    Science.gov (United States)

    Joensen, J B; Juul, S; Abrahamsen, J; Henneberg, E W; Lindholt, Jes S

    2008-01-01

    This study assesses measurement variation in the measurement of ankle systolic blood pressure (ABP) when measured with Doppler ultrasound and with the strain gauge method. Ninety-seven patients were included. ABP was measured with Doppler ultrasound and with the strain gauge method. The methods were compared graphically by scatterplots and analyzed by paired t test, analysis of variance, and Pitman's paired variance ratio test. ABP was measured by strain gauge in all extremities, whereas no Doppler signal was obtainable in 7 limbs (4%). There was no systematic difference in measurements between the means of the two measurements. However, a substantial difference of more than 25 mm Hg was found in 15% of limbs and more than 20 mm Hg in 20%. In the majority of patients, measurements of ABP by Doppler ultrasound and the strain gauge method give similar results, but for a minority the discrepancy is substantial.

  16. Noncontact blood species identification method based on spatially resolved near-infrared transmission spectroscopy

    Science.gov (United States)

    Zhang, Linna; Sun, Meixiu; Wang, Zhennan; Li, Hongxiao; Li, Yingxin; Li, Gang; Lin, Ling

    2017-09-01

    The inspection and identification of whole blood are crucially significant for import-export ports and inspection and quarantine departments. In our previous research, we proved Near-Infrared diffuse transmitted spectroscopy method was potential for noninvasively identifying three blood species, including macaque, human and mouse, with samples measured in the cuvettes. However, in open sampling cases, inspectors may be endangered by virulence factors in blood samples. In this paper, we explored the noncontact measurement for classification, with blood samples measured in the vacuum blood vessels. Spatially resolved near-infrared spectroscopy was used to improve the prediction accuracy. Results showed that the prediction accuracy of the model built with nine detection points was more than 90% in identification between all five species, including chicken, goat, macaque, pig and rat, far better than the performance of the model built with single-point spectra. The results fully supported the idea that spatially resolved near-infrared spectroscopy method can improve the prediction ability, and demonstrated the feasibility of this method for noncontact blood species identification in practical applications.

  17. Study on the measurement method of a dynamic spectrum

    International Nuclear Information System (INIS)

    Wang, Y; Li, G; Lin, L; Liu, Y L; Li, X X; Lu, Stephen C-Y

    2005-01-01

    Continuous non-invasive blood component sensing and regulation is necessary for patients with metabolism disorders. Utilizing near-infrared spectroscopy for non-invasively sensing blood component concentration has been a focus topic in biomedical optics applications. It has been shown to be versatile, speedy and sensitive to several kinds of samples. However, there is no report about any successful non-invasive blood component (except the artery blood oxygen saturation) concentration detection techniques that can meet the requirements of clinic application. One of the key difficulties is the influence of individual discrepancies. Dynamic spectrum is a new non-invasive measure method for sensing blood component concentration presented recently. It can theoretically eliminate the individual discrepancies of the tissues except the pulsatile component of the artery blood. This indicates a brand new way to measure the blood component concentration and the potential to provide absolute quantitation of hemodynamic variables. In this paper, the measurement methodology to acquire the DS from photoplethysmography (PPG) is studied. A dynamic spectrometer to acquire the DS is described

  18. Extraction of human genomic DNA from whole blood using a magnetic microsphere method.

    Science.gov (United States)

    Gong, Rui; Li, Shengying

    2014-01-01

    With the rapid development of molecular biology and the life sciences, magnetic extraction is a simple, automatic, and highly efficient method for separating biological molecules, performing immunoassays, and other applications. Human blood is an ideal source of human genomic DNA. Extracting genomic DNA by traditional methods is time-consuming, and phenol and chloroform are toxic reagents that endanger health. Therefore, it is necessary to find a more convenient and efficient method for obtaining human genomic DNA. In this study, we developed urea-formaldehyde resin magnetic microspheres and magnetic silica microspheres for extraction of human genomic DNA. First, a magnetic microsphere suspension was prepared and used to extract genomic DNA from fresh whole blood, frozen blood, dried blood, and trace blood. Second, DNA content and purity were measured by agarose electrophoresis and ultraviolet spectrophotometry. The human genomic DNA extracted from whole blood was then subjected to polymerase chain reaction analysis to further confirm its quality. The results of this study lay a good foundation for future research and development of a high-throughput and rapid extraction method for extracting genomic DNA from various types of blood samples.

  19. [Research on the Method of Blood Pressure Monitoring Based on Multiple Parameters of Pulse Wave].

    Science.gov (United States)

    Miao, Changyun; Mu, Dianwei; Zhang, Cheng; Miao, Chunjiao; Li, Hongqiang

    2015-10-01

    In order to improve the accuracy of blood pressure measurement in wearable devices, this paper presents a method for detecting blood pressure based on multiple parameters of pulse wave. Based on regression analysis between blood pressure and the characteristic parameters of pulse wave, such as the pulse wave transit time (PWTT), cardiac output, coefficient of pulse wave, the average slope of the ascending branch, heart rate, etc. we established a model to calculate blood pressure. For overcoming the application deficiencies caused by measuring ECG in wearable device, such as replacing electrodes and ECG lead sets which are not convenient, we calculated the PWTT with heart sound as reference (PWTT(PCG)). We experimentally verified the detection of blood pressure based on PWTT(PCG) and based on multiple parameters of pulse wave. The experiment results showed that it was feasible to calculate the PWTT from PWTT(PCG). The mean measurement error of the systolic and diastolic blood pressure calculated by the model based on multiple parameters of pulse wave is 1.62 mm Hg and 1.12 mm Hg, increased by 57% and 53% compared to those of the model based on simple parameter. This method has more measurement accuracy.

  20. The blood donor identity survey: a multidimensional measure of blood donor motivations.

    Science.gov (United States)

    France, Christopher R; Kowalsky, Jennifer M; France, Janis L; Himawan, Lina K; Kessler, Debra A; Shaz, Beth H

    2014-08-01

    Evidence indicates that donor identity is an important predictor of donation behavior; however, prior studies have relied on diverse, unidimensional measures with limited psychometric support. The goals of this study were to examine the application of self-determination theory to blood donor motivations and to develop and validate a related multidimensional measure of donor identity. Items were developed and administered electronically to a sample of New York Blood Center (NYBC) donors (n=582) and then to a sample of Ohio University students (n=1005). Following initial confirmatory factor analysis (CFA) on the NYBC sample to identify key items related to self-determination theory's six motivational factors, a revised survey was administered to the university sample to reexamine model fit and to assess survey reliability and validity. Consistent with self-determination theory, for both samples CFAs indicated that the best fit to the data was provided by a six-motivational-factor model, including amotivation, external regulation, introjected regulation, identified regulation, integrated regulation, and intrinsic regulation. The Blood Donor Identity Survey provides a psychometrically sound, multidimensional measure of donor motivations (ranging from unmotivated to donate to increasing levels of autonomous motivation to donate) that is suitable for nondonors as well as donors with varying levels of experience. Future research is needed to examine longitudinal changes in donor identity and its relationship to actual donation behavior. © 2014 AABB.

  1. Adjusting adiposity and body weight measurements for height alters the relationship with blood pressure in children

    Science.gov (United States)

    Willig, Amanda L.; Casazza, Krista; Dulin-Keita, Akilah; Franklin, Frank A.; Amaya, Michelle; Fernandez, Jose R.

    2010-01-01

    BACKGROUND Adiposity measures are associated with increased pediatric blood pressure. However, this correlation can be confounded by the relationship of both variables to height. We evaluated whether adiposity and anthropometric measures were associated with pediatric blood pressure before and after adjusting each value for height. METHODS Participants included 281 African-American, European-American, and Hispanic-American children aged 7–12 years. Blood pressure percentiles were calculated according to pediatric guidelines using the average of four measurements. Total fat mass was determined using dual-energy x-ray absorptiometry. Socioeconomic status was calculated with the Hollingshead index. Adiposity measures were indexed for height using log-log regression analysis. Partial correlations identified measures associated with blood pressure. Linear regression was used to test the association of those measures with absolute blood pressure, while logistic regression was used to evaluate the odds for hypertension. RESULTS More African-Americans (16.3%) presented with potential hypertension than European-American (5.1%) or Hispanic-American (2.7%) children. After adjusting for covariates, fat mass, body mass index, and waist circumference were positively significantly associated with absolute blood pressure and hypertension in African-American and European-American children (P < 0.05). When these measures were height-indexed, only waist remained significantly positively associated with hypertension risk in these two groups. No measures were significantly associated with blood pressure among Hispanic-American children. CONCLUSIONS In this multiethnic pediatric population, waist circumference was the strongest significant adiposity predictor of hypertension risk among African-American and European-American children. Additional research is needed to determine which environmental and genetic factors contribute to pediatric hypertension, particularly among Hispanic

  2. An electronic manometer for blood-pressure measurement.

    Science.gov (United States)

    Burke, M J

    1999-01-01

    This article reports the development of an electronic manometer for use in the measurement of blood pressure. It is intended to act as a replacement gauge for the mercury and aneroid manometers used in conventional sphygmomanometers. It measures pressure in the range 0-300 mm Hg (0-40 kPa) with a resolution of 1 mm Hg (0.13 kPa) and an accuracy of +/- 1 mm Hg (+/- 0.13 kPa) which is displayed on a liquid crystal display. It operates from a 9 V PP3 battery over a temperature range of 10-50 degrees C.

  3. Distribution of the pulmonary blood flow measured by ECT

    International Nuclear Information System (INIS)

    Maeda, Hisatoshi; Itoh, Harumi; Todo, Yoshiro; Ishii, Yasushi; Mukai, Takao

    1981-01-01

    Distributions of pulmonary blood flow per unit lung volume were observed by using the combination of Tc-99m-MAA and radionuclide CT. Administration of Tc-99m-MAA to the patients were performed in sitting position. Ten patients were studied with this method. In nine patients, the blood flow distribution was greater in the direction of the gravity, namely, more blood flow in the lower than the upper lung region. In six patients were demonstrated the relation between blood flow and the vertical distance described by West et al. Thus, it was possible to evaluate the arterial and venous pressures of the lung with the estimated pressure of 4.15 +- 1.93 cmH 2 O and -5.55 +- 2.48 cmH 2 O in relation to the angle of Louis. The agreement was reasonably well with that reported by Butler and Paley. Three patients had pulmonary hypertension with the distribution of monotonous increase, of which slope was similar to that of zone III in other six patients. The last patient with COPD had quite different distribution from other nine patients. (author)

  4. An assessment of various blood collection and transfer methods used for malaria rapid diagnostic tests

    Directory of Open Access Journals (Sweden)

    Baik Fred

    2007-11-01

    Full Text Available Abstract Background Four blood collection and transfer devices commonly used for malaria rapid diagnostic tests (RDTs were assessed for their consistency, accuracy and ease of use in the hands of laboratory technicians and village health workers. Methods Laboratory technicians and village health workers collected blood from a finger prick using each device in random order, and deposited the blood either on filter paper or into a suitable casette-type RDT. Consistency and accuracy of volume delivered was determined by comparing the measurements of the resulting blood spots/heights with the measurements of laboratory-prepared pipetted standard volumes. The effect of varying blood volumes on RDT sensitivity and ease of use was also observed. Results There was high variability in blood volume collected by the devices, with the straw and the loop, the most preferred devices, usually transferring volumes greater than intended, while the glass capillary tube and the plastic pipette transferring less volume than intended or none at all. Varying the blood volume delivered to RDTs indicated that this variation is critical to RDT sensitivity only when the transferred volume is very low. Conclusion None of the blood transfer devices assessed performed consistently well. Adequate training on their use is clearly necessary, with more development efforts for improved designs to be used by remote health workers, in mind.

  5. A method for estimating radioactive cesium concentrations in cattle blood using urine samples.

    Science.gov (United States)

    Sato, Itaru; Yamagishi, Ryoma; Sasaki, Jun; Satoh, Hiroshi; Miura, Kiyoshi; Kikuchi, Kaoru; Otani, Kumiko; Okada, Keiji

    2017-12-01

    In the region contaminated by the Fukushima nuclear accident, radioactive contamination of live cattle should be checked before slaughter. In this study, we establish a precise method for estimating radioactive cesium concentrations in cattle blood using urine samples. Blood and urine samples were collected from a total of 71 cattle on two farms in the 'difficult-to-return zone'. Urine 137 Cs, specific gravity, electrical conductivity, pH, sodium, potassium, calcium, and creatinine were measured and various estimation methods for blood 137 Cs were tested. The average error rate of the estimation was 54.2% without correction. Correcting for urine creatinine, specific gravity, electrical conductivity, or potassium improved the precision of the estimation. Correcting for specific gravity using the following formula gave the most precise estimate (average error rate = 16.9%): [blood 137 Cs] = [urinary 137 Cs]/([specific gravity] - 1)/329. Urine samples are faster to measure than blood samples because urine can be obtained in larger quantities and has a higher 137 Cs concentration than blood. These advantages of urine and the estimation precision demonstrated in our study, indicate that estimation of blood 137 Cs using urine samples is a practical means of monitoring radioactive contamination in live cattle. © 2017 Japanese Society of Animal Science.

  6. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....... The decrease in daytime ABPM in the intervention group was systolic/diastolic, -8  ± 12/-4 ± 7 mmHg. This did not differ significantly from the control group's -8 ± 13/-4 ± 8 mmHg. An equal number of participants obtained normal daytime ABPM, in the intervention group 17% (31/175) versus control 21% (37....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus...

  7. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  8. Optical methods in diagnostics of liver fibrosis via blood observation

    Science.gov (United States)

    Kruchinina, Margarita V.; Generalov, Vladimir M.; Atuchin, Victor V.; Kruchinin, Vladimir N.; Volodin, Vladimir A.; Gromov, Andrey A.; Rykhlitsky, Sergey V.

    2016-11-01

    A possible application of optical methods (dielectrophoresis, spectral and imaging ellipsometry, Fourier- transform infrared spectroscopy, Raman spectroscopy) for the early diagnostics in studies of red blood cells and serum in patients with the diffuse liver disease, with varying degrees of fibrosis, has been evaluated. As experimentally confirmed, the combined optical methods significantly improve the sensitivity, specificity and accuracy index in the diagnosis of both severe fibrosis and slight ulterior liver fibrosis. The identified optical methods diagnostic potential can be efficiently utilized in noninvasive screening evaluation of the stages of diffuse liver disease of various genesis.

  9. Reference measurement procedure for the determination of electrolytes in human blood via ICP-OES measurement

    Science.gov (United States)

    Grote-Koska, D.; Klauke, R.; Brand, K.; Schumann, G.

    2018-04-01

    The determination of electrolytes in human body fluids is one of the most frequently performed analyses in clinical routine laboratories. Metrological traceability of measurement results in patient samples is essential and requires the involvement of higher order reference measurement procedures wherever available. Here, the authors present the evaluation of a higher order reference system for the simultaneous determination of K+, Li+, Na+, Ca2+ and Mg2+ in blood serum and plasma. In the same order, the determined measurement performances were as follows: measurement ranges: 0.75 mmol l-1-75.0 mmol l-1, 0.05 mmol l-1-5.00 mmol l-1, 5 mmol l-1-200 mmol l-1, 0.4 mmol l-1-8.0 mmol l-1 and 0.1 mmol l-1-4.0 mmol l-1. Measurement imprecision: CVs were  ⩽1.1% for intra assay investigations and  ⩽1.8% for long term inter assay investigations for all measurands. Excellent accuracy was found testing certified Standard Reference Materials from NIST: SRM 909 (deviations from 0.0% to 1.1%) and SRM 956 (deviations from 0.0% to 1.5%). Intercomparisons with the German Metrology Institute (PTB) revealed differences from 0.1% to 0.8%. Matrix influences and carry over were not detectable. The expanded combined measurement uncertainties for the determination of the reference method values were estimated as  ⩾1.5% (k  =  2) for each measurand. The reference measurement procedure is accredited by the German accreditation body (DAkkS) in association with the German calibration service (DKD) according to ISO 17025 and ISO 15195. Services comprise the certification of calibrators, control materials and samples used in proficiency testing schemes.

  10. The continuous high-precision measurement of the density of flowing blood.

    Science.gov (United States)

    Kenner, T; Leopold, H; Hinghofer-Szalkay, H

    1977-07-29

    The "mechanical oscillator" technique for the measurement of the density of fluids is based on the influence of mass on the natural frequency of a mechanical oscillator. The practical application of this principle was worked out by Kratky et al. (1969) and Leopold (1970). It is demonstrated in this study that the method permits the continuous high-precision measurement of the density of flowing blood in anesthetized animals. The accuracy is 10(5) g/ml, the maximum sampling rate 20/min. As found in rabbits and cats during the control state, physiological blood density changes related to spontaneous blood pressure variations are up to 2-10(4) g/ml. The method can be combined with i.v. injections of isotonic and iso-oncotic solutions to determine cardiac output and blood volume on the basis of a "density dilution" principle. Since the density of the interstitial fluid is lower than that of blood, fluid shifts through the capillary walls can be detected. The effects of hypertonic glucose and of hyperoncotic dextran have been examined. Changes in the density of the arterial blood appear within 10 s after i.v. injection of these fluids. Similarly, density changes result from hemorrhage and reinfusion. During and after i.v. administration of vasoactive drugs (noradrenaline, angiotensin II, acetylcholine), marked transient changes in blood density are seen which obviously reflect the effects of fluid shifts through the capillary walls. During hemorrhagic hypotension we found periodic variations in the blood density synchronous with spontaneously occurring Mayer waves. The new method seems to be a promising tool for investigations physiological and pathological capillary fluid dynamics.

  11. Dynamic measurements of total hepatic blood flow with Phase Contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yzet, Thierry [Department of Radiology, University Hospital, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: Yzet.Thierry@chu-amiens.fr; Bouzerar, Roger [Department of Imaging and Biophysics, University Hospital, Jules Verne University of Picardie, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: bouzerar.roger@chu-amiens.fr; Baledent, Olivier [Department of Imaging and Biophysics, University Hospital, Jules Verne University of Picardie, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: Olivier.Baledent@chu-amiens.fr; Renard, Cedric [Department of Radiology, University Hospital, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: Renard.Cedric@chu-amiens.fr; Lumbala, Didier Mbayo [Department of Radiology, University Hospital, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: MbayoLumbala.Didier@chu-amiens.fr; Nguyen-Khac, Eric [Mobile Unit of Alcoology, University Hospital, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: Nguyen-Khac.Eric@chu-amiens.fr; Regimbeau, Jean-Marc [Department of Visceral and Digestive General Surgery, University Hospital, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: regimbeau.jean-marc@chu-amiens.fr; Deramond, H. [Department of Radiology, University Hospital, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: deramond.herve@chu-amiens.fr; Meyer, Marc-Etienne [Department of Imaging and Biophysics, University Hospital, Jules Verne University of Picardie, Place Victor Pauchet, 80054 Amiens cedex 1 (France)], E-mail: Meyer.Marc-Etienne@chu-amiens.fr

    2010-01-15

    Background/Aims: To measure total hepatic blood flow including portal and proper hepatic artery flows as well as the temporal evolution of the vessel's section during a cardiac cycle. Methods: Twenty healthy subjects, with a mean age of 26 years, were explored. Magnetic resonance imaging blood flow measurements were carried out in the portal vein and the proper hepatic artery. MR studies were performed using a 1.5T imager (General Electric Medical Systems). Gradient-echo 2D Fast Cine Phase Contrast sequences were used with both cardiac and respiratory gatings. Data analysis was performed using a semi-automatic software built in our laboratory. Results: The total hepatic flow rate measured was 1.35 {+-} 0.18 L/min or 19.7 {+-} 4.6 mL/(min kg). The proper hepatic artery provided 19.1% of the total hepatic blood flow entering the liver. Those measurements were in agreement with earlier studies using direct measurements. Mean and maximum velocities were also assessed and a discrepancy between our values and the literature's Doppler data was found. Measurements of the portal vein area have shown a mean variation, defined as a 'pulsatility' index of 18% over a cardiac cycle. Conclusions: We report here proper hepatic artery blood flow rate measurements using MRI. Associated with portal flow measurements, we have shown the feasibility of total hepatic flowmetry using a non-invasive and harmless technique.

  12. Low level TOC measurement method

    Science.gov (United States)

    Ekechukwu, Amy A.

    2001-01-01

    A method for the determination of total organic carbon in an aqueous sample by trapping the organic matter on a sorbent which is carbon free and analyzing the sorbent by combustion and determination of total CO.sub.2 by IR.

  13. [Practices and effects of different measures for blood pressure control in hypertension patients in Beijing, 2014].

    Science.gov (United States)

    Li, H; Dong, Z; Ma, A J; Dong, J; Fang, K; Xie, C; Qi, K; Xie, J; Zhou, Y; Zhao, Y

    2016-09-10

    Objective: To understand the practices and effects of different measures for blood pressure control in hypertension patients. Methods: Patients who have known hypertension from the subjects of "2014 Beijing adult (aged 18-79 years) chronic diseases and risk factors survey" were selected. The choices of different hypertension control measures, the relationship between the measures and demographic characteristics of hypertension patients, and the effects of different control measures were analyzed. Results: A total of 2 229 known hypertension patients were included, the analysis was conducted through a questionnaire survey. Those who answered "never taking any measures" , "taking medication according to doctor's instructions" and "taking medication when blood pressure rose" accounted for 7.0%, 79.8% and 8.3%, respectively. Those who had "diet control" , "physical exercises" and "blood pressure monitoring" accounted for 22.4%, 23.7% and 22.1%, respectively. In terms of "taking medicine according to doctor's instructions" , women (84.3%), those aged ≥60 years (87.6%), those living in urban area (81.5%), those living alone (83.8%), and Beijing local residents (82.3%) had higher compliance rates. As for "diet control" , women (24.4%), those aged ≥60 years (25.8%) and those with educational level of college or above (29.5%) had better practices. In terms of "physical exercise" , those aged ≥60 years (27.9%), those living in urban area (25.3%), those with educational level of college or above (32.5%) had better practice. Women (24.2%) and those aged ≥60 years (28.4%) had higher "blood pressure monitoring" rate. More men (9.7%), those aged 18-44 years (14.7%), those with educational level of high school (9.3%), the unmarried (18.2%), and non-Beijing local residents (14.7%) answered "never taking any measure" , and in terms of "taking medication when blood pressure rose" , non-Beijing local residents (12.8%) had higher rate. In the field survey, more patients who

  14. In vivo lateral blood flow velocity measurement using speckle size estimation.

    Science.gov (United States)

    Xu, Tiantian; Hozan, Mohsen; Bashford, Gregory R

    2014-05-01

    In previous studies, we proposed blood measurement using speckle size estimation, which estimates the lateral component of blood flow within a single image frame based on the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is "smeared") if blood flow is in the same direction as the electronically controlled transducer line selection in a 2-D image. In this observational study, the clinical viability of ultrasound blood flow velocity measurement using speckle size estimation was investigated and compared with that of conventional spectral Doppler of carotid artery blood flow data collected from human patients in vivo. Ten patients (six male, four female) were recruited. Right carotid artery blood flow data were collected in an interleaved fashion (alternating Doppler and B-mode A-lines) with an Antares Ultrasound Imaging System and transferred to a PC via the Axius Ultrasound Research Interface. The scanning velocity was 77 cm/s, and a 4-s interval of flow data were collected from each subject to cover three to five complete cardiac cycles. Conventional spectral Doppler data were collected simultaneously to compare with estimates made by speckle size estimation. The results indicate that the peak systolic velocities measured with the two methods are comparable (within ±10%) if the scan velocity is greater than or equal to the flow velocity. When scan velocity is slower than peak systolic velocity, the speckle stretch method asymptotes to the scan velocity. Thus, the speckle stretch method is able to accurately measure pure lateral flow, which conventional Doppler cannot do. In addition, an initial comparison of the speckle size estimation and color Doppler methods with respect to computational complexity and data acquisition time indicated potential time savings in blood flow velocity estimation using speckle size estimation. Further studies are needed for calculation of the speckle stretch method

  15. Out-of-office blood pressure: from measurement to control

    Directory of Open Access Journals (Sweden)

    Baguet JP

    2012-05-01

    Full Text Available Jean-Philippe Baguet1,21Department of Cardiology, University Hospital, 2Bioclinic Radiopharmaceutics Laboratory, INSERM U1039, Joseph Fourier University, Grenoble, FranceAbstract: Hypertension is an important risk factor for the development of cardiovascular disease, and is a major cause of morbidity and mortality worldwide. Traditionally, hypertension diagnosis and treatment and clinical evaluations of antihypertensive efficacy have been based on office blood pressure (BP measurements; however, there is increasing evidence that office measures may provide inadequate or misleading estimates of a patient’s true BP status and level of cardiovascular risk. The introduction, and endorsement by treatment guidelines, of 24-hour ambulatory BP monitoring and self (or home BP monitoring has facilitated more reliable and reproducible estimations of true BP, including the identification of white-coat and masked hypertension, and evaluation of BP variability. In addition, ambulatory BP monitoring enables accurate assessment of treatment effectiveness over 24 hours and both ambulatory and self BP monitoring may lead to better tailoring of therapy according to BP profile and concomitant disease. This review describes the clinical benefits and limitations of out-of-office assessments and their applications for effective management of hypertension and attainment of BP control.Keywords: ambulatory, ABPM, SBPM, blood pressure measurement, hypertension

  16. Rotating permanent magnet excitation for blood flow measurement.

    Science.gov (United States)

    Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S

    2015-11-01

    A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

  17. Relevance to Home Blood Pressure Monitoring Protocol of Blood Pressure Measurements Taken Before First- Morning Micturition and in the Afternoon

    Directory of Open Access Journals (Sweden)

    Antonio Eduardo Monteiro de Almeida

    2014-10-01

    Full Text Available Background: The importance of measuring blood pressure before morning micturition and in the afternoon, while working, is yet to be established in relation to the accuracy of home blood pressure monitoring (HBPM. Objective: To compare two HBPM protocols, considering 24-hour ambulatory blood pressure monitoring (wakefulness ABPM as gold-standard and measurements taken before morning micturition (BM and in the afternoon (AM, for the best diagnosis of systemic arterial hypertension (SAH, and their association with prognostic markers. Methods: After undergoing 24-hour wakefulness ABPM, 158 participants (84 women were randomized for 3- or 5-day HBPM. Two variations of the 3-day protocol were considered: with measurements taken before morning micturition and in the afternoon (BM+AM; and with post-morning-micturition and evening measurements (PM+EM. All patients underwent echocardiography (for left ventricular hypertrophy - LVH and urinary albumin measurement (for microalbuminuria - MAU. Result: Kappa statistic for the diagnosis of SAH between wakefulness-ABPM and standard 3-day HBPM, 3-day HBPM (BM+AM and (PM+EM, and 5-day HBPM were 0.660, 0.638, 0.348 and 0.387, respectively. The values of sensitivity of (BM+AM versus (PM+EM were 82.6% × 71%, respectively, and of specificity, 84.8% × 74%, respectively. The positive and negative predictive values were 69.1% × 40% and 92.2% × 91.2%, respectively. The comparisons of intraclass correlations for the diagnosis of LVH and MAU between (BM+AM and (PM+EM were 0.782 × 0.474 and 0.511 × 0.276, respectively. Conclusions: The 3 day-HBPM protocol including measurements taken before morning micturition and during work in the afternoon showed the best agreement with SAH diagnosis and the best association with prognostic markers.

  18. Common Genetic Polymorphisms Influence Blood Biomarker Measurements in COPD.

    Directory of Open Access Journals (Sweden)

    Wei Sun

    2016-08-01

    Full Text Available Implementing precision medicine for complex diseases such as chronic obstructive lung disease (COPD will require extensive use of biomarkers and an in-depth understanding of how genetic, epigenetic, and environmental variations contribute to phenotypic diversity and disease progression. A meta-analysis from two large cohorts of current and former smokers with and without COPD [SPIROMICS (N = 750; COPDGene (N = 590] was used to identify single nucleotide polymorphisms (SNPs associated with measurement of 88 blood proteins (protein quantitative trait loci; pQTLs. PQTLs consistently replicated between the two cohorts. Features of pQTLs were compared to previously reported expression QTLs (eQTLs. Inference of causal relations of pQTL genotypes, biomarker measurements, and four clinical COPD phenotypes (airflow obstruction, emphysema, exacerbation history, and chronic bronchitis were explored using conditional independence tests. We identified 527 highly significant (p 10% of measured variation in 13 protein biomarkers, with a single SNP (rs7041; p = 10-392 explaining 71%-75% of the measured variation in vitamin D binding protein (gene = GC. Some of these pQTLs [e.g., pQTLs for VDBP, sRAGE (gene = AGER, surfactant protein D (gene = SFTPD, and TNFRSF10C] have been previously associated with COPD phenotypes. Most pQTLs were local (cis, but distant (trans pQTL SNPs in the ABO blood group locus were the top pQTL SNPs for five proteins. The inclusion of pQTL SNPs improved the clinical predictive value for the established association of sRAGE and emphysema, and the explanation of variance (R2 for emphysema improved from 0.3 to 0.4 when the pQTL SNP was included in the model along with clinical covariates. Causal modeling provided insight into specific pQTL-disease relationships for airflow obstruction and emphysema. In conclusion, given the frequency of highly significant local pQTLs, the large amount of variance potentially explained by pQTL, and the

  19. Automatic measurement of the red cell oxygen dissociation curve identical with the whole blood curve.

    Science.gov (United States)

    Mawjood, A H; Imai, K

    1999-08-01

    Automatic measurement of the entire oxygen dissociation curve (ODC) of blood and hemoglobin provides a useful means for evaluating their gas-transport function. The automatic oxygenation apparatus previously developed by Imai et al. (1970, 1981), which uses a polarographic determination of partial pressure of oxygen and a spectrophotometric determination of oxygen saturation of hemoglobin, has mostly been used for the measurement of accurate ODCs of hemoglobin solution. However, it was not suitable for red cell suspension because a significant noise was superimposed on the absorbance signal due to light-scattering by red cells. In the present study, we have overcome this problem by using an integrating sphere for the photometric system. Through extensive tests we found the optimal experimental conditions for obtaining the red cell oxygenation data that were identical with the whole blood data with respect to the position (oxygen affinity) and shape (sigmoid character) of the ODC and its pH-dependence (the Bohr effect). The accuracy was higher than that of commercially available automatic apparatuses such as the "Hemox-Analyzer" (Technical Consulting Service) and "Hem-O-Scan" (Aminco). Thus, our method provides an easy and convenient means for obtaining accurate ODCs mimicking the whole blood ODCs from one drop of whole blood. An application of our method to the effect of blood storage on ODC is presented, demonstrating the usefulness of our method.

  20. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    DEFF Research Database (Denmark)

    Thomsen, H; Steffensen, E; Larsson, Elna-Marie

    2012-01-01

    technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose: To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC......, and glioblastomas. Results: rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r ¼ 0.60) and to the cerebellum (r ¼ 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated......-MRI using two different regions for normalization and two different measurement approaches. Material and Methods: Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and r...

  1. Methods for measurement of durability parameters

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1996-01-01

    Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included.......Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included....

  2. Principles of the tracer method in assessing regional blood flow

    International Nuclear Information System (INIS)

    Potchen, E.J.; Siegel, B.; Meidinger, R.

    1972-01-01

    The standard brain scan is abnormal when there is relative increase in blood volume or when there is an abnormal permeability to substances which normally cannot enter the brain tissue. The usual mechanism of abnormal permeability is based upon neovascularity in tissues which do not maintain the tight junctions one sees in the normal brain endothelium. These tight junctions prohibit the leakage of materials from the intra- to extravascular space, and when they are not available many materials can readily transit into the abnormal tissue substance and can therefore be discerned on a standard brain scan. In many instances, however, there is no gross breakdown in this blood-brain barrier, but more subtle derangement may be detected by determining changes in regional brain blood volume or the relative volume of distribution of various labeled materials. We have studied whether or not we can discern differences in brain spaces of two isotopes in experimental situations where the brain scan would be normal. For these models, we have used water-induced brain edema and triethyl-tin-induced brain edema in the experimental animal. In water intoxication, there is no difference in the microvascular anatomy or change in the 99 /sup m/Tc pertechnetate space, but it is apparent from our studies that the brain swells at the expense of brain blood volume and by measuring brain blood volume against brain mass, i.e., transit of 131 I antipyrine versus 51 Cr labeled red cells, one can detect brain edema in a situation where the brain scan would be normal. It is these approaches with cameras and computers using dual energies that may afford a more simplified estimation of altered regional brain function than is now available with the internal carotid injection technique. (U.S.)

  3. Clinical aviation medicine research : comparison of simultaneous measurements of intra-aortic and auscultatory blood pressures with pressure-flow dynamics during rest and excercise.

    Science.gov (United States)

    1966-10-01

    The study provides correlative information with respect to the comparative accuracy of the traditional 'cuff' clinical method of obtaining blood pressure and the laboratory catheterization procedure which measures actual blood pressure. The informati...

  4. Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs

    International Nuclear Information System (INIS)

    Hale, S.L.; Alker, K.J.; Kloner, R.A.

    1988-01-01

    Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nuclides. Simultaneous blood flow measurements with two nuclide-labeled and two colored microspheres were performed after coronary occlusion in dogs. Both techniques show a within-method correlation of r greater than 0.98. Duplicate variability for paired RMBF values in 80 samples was 8.7 +/- 0.1% when computed with radioactive microspheres and 13.2 +/- 1.8% when computed with colored microspheres. There was a good correlation in the measurement of RMBF between the radioactive- and colored-microsphere methods (r = 0.98). The best-fitting linear regression line was expressed by the formula: Colored-microsphere RMBF = 1.11 (radioactive-microsphere RMBF)-0.02. When measured by colored microspheres, RMBF was approximately 8% higher than when computed with radioactive microspheres for blood flow values of 0-2 ml/min/g. When blood flow was increased pharmacologically to levels of 2-7.5 ml/min/g, colored microspheres yielded blood flow values 39% higher than the values computed by radioactive microspheres. We conclude that the nonradioactive, colored-microsphere method correlates with the radioactive technique, but at high flows, it yields values greater than those obtained with radioactive microspheres

  5. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  6. Measurements of blood flow to individual glomeruli in the ophidian kidney.

    Science.gov (United States)

    Yokota, S D; Dantzler, W H

    1990-06-01

    Continuous measurements of the instantaneous rate of blood flow to individual glomeruli in a normal vertebrate kidney were made in the garter snake Thamnophis sirtalis. Epifluorescence video microscopy was used to visualize and record blood flow in the afferent arterioles of superficial nephrons. The dual-slit method was used for the determination of red blood cell (RBC) velocity from the video replay. Simultaneous measurements of the vessel diameter allowed the continuous determination of the instantaneous rate of blood flow. A total of 100 glomeruli was surveyed in 12 animals. These glomeruli displayed both constant and highly variable rates of blood flow, with 21% of all nephrons displaying intermittent glomerular perfusion. The mean single-nephron blood flow rate (SNBFR) for all individuals was 23.9 +/- 10.3 (SD) nl/min (n = 12). The percentage of nephrons with intermittent flow for an individual animal increased significantly with increasing plasma osmolality. Intermittency was associated with low SNBFR values; SNBFR averaged 13.5 +/- 10.2 (SD) nl/min (n = 21) in intermittent nephrons and 29.2 +/- 19.0 (SD) nl/min (n = 79) in continuous flow nephrons, the difference being significant (P less than 0.001). Nephrons with continuous perfusion displayed a much greater range of SNBFR values than intermittent nephrons. This suggests that, although changes in whole kidney glomerular filtration rate (GFR) in reptiles need not involve glomerular intermittency, intermittency may lower GFR.

  7. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  8. Comparison of spectroscopically measured finger and forearm tissue ethanol concentration to blood and breath ethanol measurements

    Science.gov (United States)

    Ridder, Trent D.; Hull, Edward L.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2011-02-01

    Previous works investigated a spectroscopic technique that offered a promising alternative to blood and breath assays for determining in vivo alcohol concentration. Although these prior works measured the dorsal forearm, we report the results of a 26-subject clinical study designed to evaluate the spectroscopic technique at a finger measurement site through comparison to contemporaneous forearm spectroscopic, venous blood, and breath measurements. Through both Monte Carlo simulation and experimental data, it is shown that tissue optical probe design has a substantial impact on the effective path-length of photons through the skin and the signal-to-noise ratio of the spectroscopic measurements. Comparison of the breath, blood, and tissue assays demonstrated significant differences in alcohol concentration that are attributable to both assay accuracy and alcohol pharmacokinetics. Similar to past works, a first order kinetic model is used to estimate the fraction of concentration variance explained by alcohol pharmacokinetics (72.6-86.7%). A significant outcome of this work was significantly improved pharmacokinetic agreement with breath (arterial) alcohol of the finger measurement (mean kArt-Fin = 0.111 min-1) relative to the forearm measurement (mean kArt-For = 0.019 min-1) that is likely due to the increased blood perfusion of the finger.

  9. Visual estimation versus gravimetric measurement of postpartum blood loss: a prospective cohort study.

    Science.gov (United States)

    Al Kadri, Hanan M F; Al Anazi, Bedayah K; Tamim, Hani M

    2011-06-01

    One of the major problems in international literature is how to measure postpartum blood loss with accuracy. We aimed in this research to assess the accuracy of visual estimation of postpartum blood loss (by each of two main health-care providers) compared with the gravimetric calculation method. We carried out a prospective cohort study at King Abdulaziz Medical City, Riyadh, Saudi Arabia between 1 November 2009 and 31 December 2009. All women who were admitted to labor and delivery suite and delivered vaginally were included in the study. Postpartum blood loss was visually estimated by the attending physician and obstetrics nurse and then objectively calculated by a gravimetric machine. Comparison between the three methods of blood loss calculation was carried out. A total of 150 patients were included in this study. There was a significant difference between the gravimetric calculated blood loss and both health-care providers' estimation with a tendency to underestimate the loss by about 30%. The background and seniority of the assessing health-care provider did not affect the accuracy of the estimation. The corrected incidence of postpartum hemorrhage in Saudi Arabia was found to be 1.47%. Health-care providers tend to underestimate the volume of postpartum blood loss by about 30%. Training and continuous auditing of the diagnosis of postpartum hemorrhage is needed to avoid missing cases and thus preventing associated morbidity and mortality.

  10. Comparison of near-infrared spectroscopy with CT cerebral blood flow measurements in newborn piglets

    Science.gov (United States)

    Brown, Derek W.; Picot, Paul A.; Springett, Roger; Delpy, David T.; Lee, Ting-Yim

    2001-05-01

    Severely premature infants are often at high risk of cerebral hemorrhage or ischemic injury due to their inability to properly regulate blood flow to the brain. If blood flow is too high, the infant is at risk of cerebral hemorrhage, while too little blood flow can result in ischemic injury. The purpose of this research is to design and develop a means of non-invasively measuring cerebral blood flow (CBF) with near infrared spectroscopy (NIRS). Such a device would greatly aid the diagnosis and monitoring of afflicted infants. Previous attempts to measure CBF with NIRS have achieved limited success. In this study we acquired high signal-to-noise NIR spectrum from 600 to 980 nm with a cooled CCD spectrometer. This spectrometer enables the differential path length factor (DPF) to be estimated with accuracy using a second derivative technique described by Matcher et al. The validity of our new approach is determined via direct comparison with a previously validated computed tomography (CT) method. Three newborn piglets were studied. CBF measurements were performed at various partial arterial CO2 tensions (PaCO2) using both the NIRS and CT methods. The results of the two methods correlate well with a relationship of CBFCT equals -4.30 + 1.05 CBFNIRS (r2 equals 0.96).

  11. Improvement of the accuracy of continuous hematocrit measurement under various blood flow conditions

    Science.gov (United States)

    Kim, Myounggon; Yang, Sung

    2014-04-01

    We propose an accurate method for continuous hematocrit (HCT) measurement of flowing blood under varying plasma conditions of electrical conductivity, osmolality, and flow rate. Two parameters, namely the hematocrit estimation parameter (HEP) and normalized difference, are proposed to reduce the HCT measurement error. HEP was demonstrated in a previous work. The results of multiple linear regression analysis showed that the two parameters were strongly correlated with the reference HCT measured by microcentrifugation. The measurement error was less than 9% despite significant simultaneous variations in the plasma properties and shear rate.

  12. Precision of INR measured with a patient operated whole blood coagulometer

    DEFF Research Database (Denmark)

    Attermann, Jørn; Andersen, Niels Trolle; Korsgaard, Helle

    2003-01-01

    INTRODUCTION: The objective of the present study was to evaluate the precision of a portable whole blood coagulometer (CoaguChek S) in the hands of self-managing patients on oral anticoagulant therapy (OAT). MATERIALS AND METHODS: Fifteen patients on self-managed OAT performed measurements of INR...... by two types of portable whole blood coagulometers (CoaguChek and CoaguChek S) at home for 10 weeks. RESULTS: The coefficient of variation (CV) of INRs determined at home by CoaguChek S by patients on self-managed OAT was 5.5% (95% confidence limits: 4.9%, 6.1%). The biological CV of INR within...

  13. [Measurement of the blood flow in various areas of the rat brain by means of microspheres].

    Science.gov (United States)

    Deroo, J; Gerber, G B

    1976-01-01

    A method is described to measure regional blood flow in different structures of the rat brain. Microspheres (15 micron) are injected, the brain is sectioned, stained for myeline, radioautographs are prepared and the microspheres in the different structures are counted. The values obtained for different brain structures are counted. The values obtained for different brain regions (cortex, corpus callosum, thalamus hipocampus, hypothalamic region, colliculi, cerebellum, pons, medulla) compare well with those published by others on larger animals. In rats fed 1% of lead from birth, higher blood flow is found in the cortex and a lower one in the interior part of the brain compared to controls.

  14. Quantitative measurement of the blood flow in peripheral vascular diseases by a new radionuclide plethysmography

    Energy Technology Data Exchange (ETDEWEB)

    Kawakami, K.; Mori, Y.; Mashima, Y.; Shimada, T.; Fukuoka, M.

    1985-05-01

    The purpose of the study is to introduce a new plethysmography using radionuclide (RN) for a quantitative measurement of the blood flow in the extremities following the routine RN angiography. Seventy five patients with various peripheral artery diseases have been examined. RN pletysmography was performed in the supine position 15 min. after the RN angiography using 15 mCi of Tc-99m RBC. The blood flow (F) was calculated by the equation (1) which consists of three parameters, the initial slope of the time-activity curve (dc/dt*t=0) after the venous occlusion on the thigh, changes of radio-activity (C-Co) before and after avascularization by inflation of cuff with 200 mmHg pressure at calf, and the blood volume per unit tissue volume (..beta..=Vb/V,ml/100g tissue). F (ml/min/100g) = ..beta.. (dc/dt*t=0)/C-Co. The blood flow measured simultaneously by RN plethysmography and admittance plethysmography was significantly correlated (r = 0.906,n = 16). The blood flow in 67 normal subjects was 2.78 +- 0.75 ml/min/100g. In the patients with intermittent claudication the blood flow was decreased (1.89 +- 0.75 ml/min/100g,n = 75). In the cases with poorly developed colateral circulation the blood flow markedly decreased (1.62 +- 0.29 ml/min/100g,n = 10). Increases of blood flow after exercise was small in the cases with stenosis, even in patients with collaterals. This method is very useful to evaluate quantitatively the peripheral hemodynamics following the routine RN angiographic examination.

  15. Measurement of blood calprotectin (MRP-8/MRP-14) levels in patients with juvenile idiopathic arthritis.

    Science.gov (United States)

    Bojko, Jaryna

    2017-01-01

    The aim of the investigation was to compare blood calprotectin (MRP8/14, S100A 8/9) levels in patients with systemic-onset, polyarticular, RF-negative and oligoarticular subtypes of juvenile idiopathic arthritis (JIA), and to explore links between blood calprotectin levels and clinical and laboratory markers of JIA activity. Measurement of calprotectin in blood serum was performed in 160 patients with JIA followed up at Lviv Regional Council Public Institution "Western-Ukrainian Specialised Children's Medical Centre". Seventeen patients with systemic-onset JIA (sJIA) and 49 patients with other JIA subtypes (RF-negative polyarthritis and oligoarthritis) in the active phase of the disease were included in this study. Determination of calprotectin levels in blood serum was performed using EK-MRP8/14 Buhlmann Calprotectin reagents (Buhlmann, Switzerland) by the ELISA method. The results of the investigations showed that blood calprotectin levels were higher in patients with systemic-onset subtype of the disease (median 13,800 ng/ml), and differed significantly from levels in healthy children (median 1,800 ng/ml, p = 0.00002), levels in patients with articular subtypes of JIA (median 2,700 ng/ml, p = 0.000008), and patients with RF-negative polyarthritis (median 3,800 ng/ml, p = 0.003226) and oligoarthritis (median 2,500 ng/ml, p = 0.000009). The highest blood calprotectin levels were found in patients with newly diagnosed sJIA, the median being 32,500 ng/ml (range: 13,800-177,000 ng/ml). Direct correlations were found between blood calprotectin and JADAS 27 activity score ( p = 0.000009), ESR ( p = 0.000079) and CRP ( p = 0.000058). Blood calprotectin level is one of the measures that can be used to confirm the diagnosis of sJIA and to monitor the disease activity and therapy effectiveness.

  16. Cerebral blood oxygenation measurements in neonates with optoacoustic technique

    Science.gov (United States)

    Herrmann, Stephen; Petrov, Irene Y.; Petrov, Yuriy; Richardson, C. Joan; Fonseca, Rafael A.; Prough, Donald S.; Esenaliev, Rinat O.

    2017-03-01

    Cerebral hypoxia is a major contributor to neonatal/infant mortality and morbidity including severe neurological complications such as mental retardation, cerebral palsy, motor impairment, and epilepsy. Currently, no technology is capable of accurate monitoring of neonatal cerebral oxygenation. We proposed to use optoacoustics for this application by probing the superior sagittal sinus (SSS), a large central cerebral vein. We developed and built a multi-wavelength, optical parametric oscillator (OPO) and laser diode optoacoustic systems for measurement of SSS blood oxygenation in the reflection mode through open anterior or posterior fontanelles and in the transmission mode through the skull in the occipital area. In this paper we present results of initial tests of the laser diode system for neonatal cerebral oxygenation measurements. First, the system was tested in phantoms simulating neonatal SSS. Then, using the data obtained in the phantoms, we optimized the system's hardware and software and tested it in neonates admitted in the Neonatal Intensive Care Unit. The laser diode system was capable of detecting SSS signals in the reflection mode through the open anterior and posterior fontanelles as well as in the transmission mode through the skull with high signal-to-noise ratio. Using the signals measured at different wavelengths and algorithms developed for oxygenation measurements, the laser diode system provided real-time, continuous oxygenation monitoring with high precision at all these locations.

  17. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  18. A Study on Anthropometric Measurements, Blood Pressure, Blood Sugar and Food Intakes Among Different Social Status and Ethnicities

    Directory of Open Access Journals (Sweden)

    Jafarirad

    2016-09-01

    Full Text Available Background Metabolic syndrome is a disorder that increases the risk of cardiovascular disease and diabetes. Objectives The aim of the study was to evaluate some risk factors of the metabolic syndrome and food intakes among people who lived in Ahvaz City, Iran. Methods It was a filed study that was conducted on 211 subjects who participated in health exhibition. Socioeconomic status and ethnicity were asked by a general questionnaire. Weight, height, body mass index, waist circumference (WC and WC to hip circumference ratio (WHR were obtained. Blood sugar was measured by a glucometer. Systolic and diastolic blood pressures were obtained and dietary intakes were assessed by a brief instrument. Results There was a significant difference in weight, height, WC, WHR and systolic blood pressure among different jobs. Workers had more intakes of cake and sweets. Arab subjects had more intakes of bread and fishes and Persians more intakes of vegetables. Soda, chocolate and candy were more consumed by Kurd ethnicity. Conclusions Job may be accounted as an important effective socioeconomic factor related to metabolic syndrome risk factors; also different cultures due to different ethnicities may have an influence on lifestyle and dietary intakes.

  19. Method for the Determination of Iodide in Dried Blood Spots from Newborns by High Performance Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Kim, Un-Jung; Kannan, Kurunthachalam

    2018-03-06

    Dried blood spots (DBS), collected for newborn screening programs in the United States, have been used to screen for congenital metabolic diseases in newborns for over 50 years. DBS provide an easy and inexpensive way to collect and store peripheral blood specimens and present an excellent resource for studies on the assessment of chemical exposures in newborns. In this study, a selective and sensitive method was developed for the analysis of iodide in DBS by high performance liquid chromatography electrospray tandem mass spectrometry. Accuracy, inter- and intraday precision, matrix effects, and detection limits of the method were determined. Further validation of the method was accomplished by concurrent analysis of whole blood and fortified blood spotted on a Whatman 903 filter card. A significant positive correlation was found between measured concentrations of iodide in venous whole blood and the same blood spotted as DBS. The method limit of detection was 0.15 ng/mL iodide. The method was further validated by the analysis of a whole blood sample certified for iodide levels (proficiency testing sample) by spotting on a filter card. Twenty DBS samples collected from newborns in New York State were analyzed to demonstrate the applicability of the method. The measured concentrations of iodide in whole blood of newborns from New York State ranged between method is applicable for the analysis of DBS collected for epidemiological studies that investigate the importance of iodide on the health of newborns.

  20. Dynamic Electrochemistry Corrects for Hematocrit Interference on Blood Glucose Determinations with Patient Self-Measurement Devices

    Science.gov (United States)

    Musholt, Petra B; Schipper, Christina; Thomé, Nicole; Ramljak, Sanja; Schmidt, Marc; Forst, Thomas; Pfützner, Andreas

    2011-01-01

    Background It has been demonstrated that dynamic electrochemistry can be used to correct blood glucose measurement results for potentially interfering conditions, such as humidity, hematocrit (HCT) variations, and ascorbic acid. The purpose of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of blood glucose meters applying different measurement technologies. Methods Venous heparinized whole blood was drawn, immediately aliquoted, and manipulated to contain three different blood glucose concentrations (80, 155, and 310 mg/dl) and five different hematocrit levels (25%, 37%, 45%, 52%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured 8 times with the following devices: BGStar, Contour, Accu-Chek Aviva, Accu-Chek Aviva Nano, Breeze 2, Precision Xceed, OneTouch Ultra 2, OneTouch Verio, FreeStyle Freedom Lite, Glucocard G+, GlucoMen LX, GlucoMen GM, and StatStrip [point-of-care (POC) device]. Cobas (Roche Diagnostics, glucose hexokinase method) served as laboratory plasma reference method. Stability to hematocrit influence was assumed when less than 10% bias occurred between the highest and lowest hematocrit levels when analyzing mean deviations for all three glucose concentrations. Results Besides the POC StatStrip device, which is known to measure and correct for hematocrit (resulting in hematocrit variations occur in daily routine (e.g., because of smoking, exercise, hypermenorrhea, pregnancy, stay in mountains, and hemodialysis), our results may encourage use of meters with stable performance under these conditions. Dynamic electrochemistry as used in the BGStar device (sanofi-aventis) appears to be an effective technology to correct for potential hematocrit influence on the meter results. PMID:22027312

  1. Measurements of enlarged blood pump models using Laser Doppler Anemometer.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In an earlier study (Chua et al., 1998, 1999a), a 5:1 enlarged model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump (Akamatsu et al., 1995) with five different impeller blade profiles was designed and constructed. Their respective flow characteristics with respect to (1) the three different blade profile designs: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed were investigated. Among the five impeller designs, the results obtained suggested that impellers A and C designs should be adopted if higher head is required. Impellers A and C therefore were selected for the flow in between their blades to be measured using Laser Doppler Anemometer (LDA), so as to have a better understanding of the flow physics with respect to the design parameters.

  2. Method for breast cancer diagnosis by phase spectrophotometry of human blood plasma

    Science.gov (United States)

    Mintser, Ozar P.; Oliinychenko, B. P.

    2012-01-01

    The possibility of breast cancer diagnostics by means of phase structure measurements of laser radiation transformed by human blood plasma samples. The theoretical fundamentals of polarization filtration method for direct phase shifts measurements of microscopic images are provided. The optical model of polycrystalline networks of blood plasma proteins is suggested. The results of investigating the interrelation between the values of statistical (statistical moments of the 1st-4th order), correlation (correlation area, asymmetry coefficient and autocorrelation function excess) and fractal (dispersion of logarithmic dependencies of power spectra) parameters are presented. They characterize the coordinate distributions of phase shifts between the orthogonal components of the amplitude in the points of laser images of blood plasma smears and pathological changes in the mammary gland tissue. The diagnostic criteria of breast cancer nascency are determined.

  3. Adaptive Clutter Filtering for Improved Measurement of Cardiac Blood Velocities

    OpenAIRE

    Vågsholm, Beate Haram

    2017-01-01

    In ultrasound color flow images of the heart, irregular blood flow patterns might be an early indication of heart disease. The blood flow is possible to image using multi-dimensional blood velocity estimation like speckle tracking. In order to image the blood flow, the signal from the surrounding tissue must be attenuated, and this is often termed clutter filtering. Insufficient clutter filtering might cause bias in the velocity estimation. It is difficult to design filters with a fixed cut-o...

  4. Method of measuring luminescence of a material

    Science.gov (United States)

    Miller, Steven D.

    2015-12-15

    A method of measuring luminescence of a material is disclosed. The method includes applying a light source to excite an exposed material. The method also includes amplifying an emission signal of the material. The method further includes measuring a luminescent emission at a fixed time window of about 10 picoseconds to about 10 nanoseconds. The luminescence may be radio photoluminescence (RPL) or optically stimulated luminescence (OSL).

  5. Identification of heart disease-prone personality using oscillometric blood pressure measurements.

    Science.gov (United States)

    Jung, Seungah; Shin, Youngsuk

    2015-01-01

    By using the conventional method of measuring two-points (systolic and diastolic) blood pressure, it is difficult to differentiate a heart disease-prone personality from normals. Recently, an oscillometric method that reflects the personalized trait of blood pressure was developed by one author. By using this new measurement technique, this study intended to test the possibility of differentiating a heart disease-prone personality (type A or type D) from normal people. TPA scale in MMPI-2 and DS14 were used for screening type A and D. Oscillometric waveforms created by the cuff pressure were segmented into window blocks based on a single beat at a minimum, allowing this method to extract maximal top and bottom amplitudes in each window block. Then, a spectrogram using a short-time Fourier transform was applied to discriminate between character types in extracted blood pressure patterns with linear discriminant analysis. Compared to a normal personality, type A and type D personalities displayed a lower frequency response on STFT with maximum negative amplitudes than normals. In particular, the type D personality showed a lower frequency response than the type A personality. These results could provide a new qualitative method for measuring different biological indices between type A or D personalities and normals.

  6. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    Science.gov (United States)

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  7. Reliability and validity of optoelectronic method for biophotonical measurements

    Science.gov (United States)

    Karpienko, Katarzyna; Wróbel, Maciej S.; UrniaŻ, Rafał

    2013-11-01

    Reliability and validity of measurements is of utmost importance when assessing measuring capability of instruments developed for research. In order to perform an experiment which is legitimate, used instruments must be both reliable and valid. Reliability estimates the degree of precision of measurement, the extent to which a measurement is internally consistent. Validity is the usefulness of an instrument to perform accurate measurements of quantities it was designed to measure. Statistical analysis for reliability and validity control of low-coherence interferometry method for refractive index measurements of biological fluids is presented. The low-coherence interferometer is sensitive to optical path difference between interfering beams. This difference depends on the refractive index of measured material. To assess the validity and reliability of proposed method for blood measurements, the statistical analysis of the method was performed on several substances with known refractive indices. Analysis of low-coherence interferograms considered the mean distances between fringes. Performed statistical analysis for validity and reliability consisted of Grubb's test for outliers, Shapiro-Wilk test for normal distribution, T-Student test, standard deviation, coefficient of determination and r-Pearson correlation. Overall the tests proved high statistical significance of measurement method with confidence level measurement method.

  8. Cerebral blood flow (CBF) with 133Xe inhalation method

    International Nuclear Information System (INIS)

    Kusunoki, Tadaki; Masumura, Michio; Tamaki, Norihiko; Matsumoto, Satoshi; Yamashita, Hideyuki.

    1982-01-01

    The effects of CO 2 inhalation on the cerebral blood flow (CBF) were examined with 133 Xe inhalation method (Novo Inhalation Cerebrograph) on 9 normal peoples and 20 patients. Nine normal peoples were divided into 3 groups consisting of each 3 peoples, namely young age group, middle age group, and old age group. Each increased CBF (%) by CO 2 inhalation was 40 -- 44 in young age group, 36 -- 37 in middle age group, and 35 -- 36 in old age group in the blood flow of the first compartment (F 1 ), and 27 -- 28 in young age group, 30 -- 31 in middle age group and 23 -- 24 in old age group in the initial slope index (ISI). Each CO 2 reactivity factor (RF) was 5.5 -- 5.8 in young age group, 3.8 -- 4.0 in middle age group and 3.3 in old age group in F 1 , and 3.1 -- 3.2 in young age group, 2.0 -- 3.3 in middle age group, and 1.2 -- 1.3 in old age group in ISI. Twenty patients consisted of 15 patients of occlusive cerebrovascular disease, 2 patients of head injury, 2 patients of normal pressure hydrocephalus and one patient of subarachnoid hemorrhage. RF was abnormally lower than normal value in 5 patients in F 1 , but in 7 in ISI. Clinical benefits of CBF study during CO 2 inhalation with 133 Xe inhalation method were discussed. (author)

  9. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before...... and after ventilation with a gas mixture containing 20-50 ml of CO for a period of 10-15 min. A special Water's to and fro system was designed in order to avoid any leakage when measuring during intermittent positive pressure ventilation (IPPV). Blood samples were taken before and immediately after...... patients. The coefficients of variation were 6.2% and 4.7% in healthy and diseased subjects, respectively. Furthermore, the day-to-day variation of the method with respect to the total amount of circulating hemoglobin (nHb) and CBV was determined from duplicate estimates separated by 24-48 h. In conclusion...

  10. Uncertainty in measurements of ¹⁸F blood concentration and its effect on simplified dynamic PET analysis.

    Science.gov (United States)

    Sattarivand, Mike; Borel, Santa; Armstrong, Jennifer; Kusano, Maggie; Poon, Ian; Caldwell, Curtis

    2014-03-01

    The purpose of this study was to assess the accuracy and practicality of well counter- and thyroid probe-based methods, commonly available in nuclear medicine facilities, for measuring the concentration of (18)F-FDG in blood samples. The degree to which the accuracy of such methods influences quantitative analysis of dynamic PET scans was also assessed. Thirty-five patients with cancer of the head and neck underwent dynamic PET imaging as part of a study intended to evaluate the utility of quantitative, image-based metrics for assessment of early treatment response. The activity in blood samples from the patients, necessary to provide an estimate of the input function for quantitative analysis, was measured both using a thyroid probe and using a well counter. Three calibration techniques were compared: single-point calibration using a standard solution for the thyroid probe (ProbePoint technique), single-point calibration using a standard solution for the well counter (WellPoint technique), and multiple-point calibration over the full range of expected blood activities for the well counter (WellCurve technique). The WellCurve method was assumed to provide the most accurate estimate of blood activity. The precision of measuring blood volume using a micropipette was also evaluated by obtaining multiple blood samples. Simplified-kinetic-analysis multiple-time-point (SKA-M) uptake rates for the primary tumor were calculated for all 35 patients using PET images and each of the 3 methods for assessing blood concentration. Errors in blood activity measurements ranging from -9.5% to 7.6% were found using the ProbePoint method, whereas the error range was much less (from -1.3% to 0.9%) for the WellPoint method. The precision in blood volume measurements ranged from -6% to 12% in the 10 patients assessed. The errors in blood activity and volume measurements were reflected in the SKA-M measurements in the same range. The WellPoint method provides a compromise between accuracy

  11. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... (ICC) and limits of agreement. RESULTS: Fifteen minutes of hyperoxia was accompanied by mean reductions in arterial and venous perfusion velocities of 14% and 16%, respectively (p = 0.0080; p = 0.0019), constriction of major arteries and veins by 5.5% and 8.2%, respectively (p ...). For perfusion velocities, short-term ICCs were 0.79-0.82 and long-term ICCs were 0.06-0.11. Intersession increases in blood glucose were associated with reductions in perfusion velocities (arterial p = 0.0067; venous p = 0.018). CONCLUSION: Oxygen reactivity testing supported that motion-contrast velocimetry...

  12. In the aftermath of SPRINT: further comparison of unattended automated office blood pressure measurement and 24-hour blood pressure monitoring.

    Science.gov (United States)

    Seidlerová, Jitka; Gelžinský, Julius; Mateřánková, Markéta; Ceral, Jiří; König, Petr; Filipovský, Jan

    2018-03-22

    Several papers reported that unattended automated office blood pressure (uAutoOBP) is closely related to daytime ambulatory blood pressure monitoring (ABPM). In the present study, we aim to study uAutoOBP and its relation to 24-hour ABPM and ABPM variability. Stable treated hypertensive subjects were examined in two Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP three times with auscultatory method (AuscOBP) by the physician. ABPM was performed within one week from the clinical visit. Data on 98 subjects aged 67.7 ± 9.3 years with 24-hour ABPM 120.3 ± 10.6/72.7 ± 7.9 mm Hg are reported. uAutoOBP was lower than 24-hour (by -5.2 ± 11.3/-0.5 ± 6.9 mm Hg) and daytime (by -6.7 ± 12.82.4 ± 8.0 mm Hg) ABPM and the individual variability of the difference was very large (up to 30 mm Hg). The correlation coefficients between ABPM and uAutoOBP were similar compared to AuscOBP (p ≥ .17). Variability of uAutoOBP, but not AuscOBP, readings during one clinical visit was related to short-term blood pressure variability of ABPM. The difference between AuscOBP and uAutoOBP was larger in patients with white-coat effect compared to other blood pressure control groups (25.1 ± 7.0 vs. 2.2 ± 10.3 mm Hg; p = .0036). Our study shows that uAutoOBP is not good predictor of ambulatory blood pressure monitoring, not even of the daytime values. It might, however, indicate short-term blood pressure variability and, when compared with AuscOBP, also detect patients with white-coat effect.

  13. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic. ...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior......The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...

  14. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  15. Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter

    International Nuclear Information System (INIS)

    Zhang, Qiang; Chen, Xianxiang; Fang, Zhen; Xue, Yongjiao; Xia, Shanhong; Zhan, Qingyuan; Yang, Ting

    2017-01-01

    The present study designs an algorithm to increase the accuracy of continuous blood pressure (BP) estimation. Pulse arrival time (PAT) has been widely used for continuous BP estimation. However, because of motion artifact and physiological activities, PAT-based methods are often troubled with low BP estimation accuracy. This paper used a signal quality modified Kalman filter to track blood pressure changes. A Kalman filter guarantees that BP estimation value is optimal in the sense of minimizing the mean square error. We propose a joint signal quality indice to adjust the measurement noise covariance, pushing the Kalman filter to weigh more heavily on measurements from cleaner data. Twenty 2 h physiological data segments selected from the MIMIC II database were used to evaluate the performance. Compared with straightforward use of the PAT-based linear regression model, the proposed model achieved higher measurement accuracy. Due to low computation complexity, the proposed algorithm can be easily transplanted into wearable sensor devices. (paper)

  16. Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter

    Science.gov (United States)

    Zhang, Qiang; Chen, Xianxiang; Fang, Zhen; Xue, Yongjiao; Zhan, Qingyuan; Yang, Ting; Xia, Shanhong

    2017-02-01

    The present study designs an algorithm to increase the accuracy of continuous blood pressure (BP) estimation. Pulse arrival time (PAT) has been widely used for continuous BP estimation. However, because of motion artifact and physiological activities, PAT-based methods are often troubled with low BP estimation accuracy. This paper used a signal quality modified Kalman filter to track blood pressure changes. A Kalman filter guarantees that BP estimation value is optimal in the sense of minimizing the mean square error. We propose a joint signal quality indice to adjust the measurement noise covariance, pushing the Kalman filter to weigh more heavily on measurements from cleaner data. Twenty 2 h physiological data segments selected from the MIMIC II database were used to evaluate the performance. Compared with straightforward use of the PAT-based linear regression model, the proposed model achieved higher measurement accuracy. Due to low computation complexity, the proposed algorithm can be easily transplanted into wearable sensor devices.

  17. Monitoring total boron in blood for BNCT by a novel atomic emission method

    International Nuclear Information System (INIS)

    Laakso, J.; Kulvik, M.; Ruokonen, I.; Vaehaetalo, J.; Faerkkilae, M.; Kallio, M.; Zilliacus, R.

    2000-01-01

    In BNCT the duration and timing of the is adjusted by 10 B concentrations in whole blood. Time-frame for determinations is less than 20 minutes. Therefore fast and accurate boron determinations are a prerequisite for BNCT. We present a method based on ICP-AES instrument for whole blood and plasma boron determinations with protein precipitation with trichloroacetic acid as sample pre-treatment and beryllium as an internal standard. The method was compared to established but tedious ICP-mass spectrometric method with wet ashing as a sample pre-treatment. The ICP-AES method is in good agreement (correlation coefficient 0.99) the ICP-MS. Within-day and between-day imprecisions were less than 3,5% CV for whole blood samples. Samples taken during and after BPA-F infusion (290 mg/kg) revealed an uneven distribution between plasma and erythrocytes. The present method is feasible and one of the fastest currently available for BNCT. Our results indicate that BPA-F or its metabolites do not seem to be tightly bound to plasma proteins. It also seems that determination of boron in plasma sample may be preferable than measuring boron in whole blood. (author)

  18. Using qualitative research methods in biomedical innovation: the case of cultured red blood cells for transfusion.

    Science.gov (United States)

    Lyall, Catherine; King, Emma

    2016-05-11

    Qualitative research has a key role to play in biomedical innovation projects. This article focuses on the appropriate use of robust social science methodologies (primarily focus group studies) for identifying the public's willingness and preference for emerging medical technologies. Our study was part of the BloodPharma project (now known as the Novosang project) to deliver industrially generated red blood cells for transfusion. Previous work on blood substitutes shows that the public prefers donated human blood. However, no research has been conducted concerning attitudes to stem cell derived red blood cells. Qualitative research methods including interviews and focus groups provide the methodological context for this paper. Focus groups were used to elicit views from sub-sections of the UK population about the potential use of such cultured red blood cells. We reflect on the appropriateness of that methodology in the context of the BloodPharma project. Findings are in the form of lessons transferable to other interdisciplinary, science-led teams about what a social science dimension can bring; why qualitative research should be included; and how it can be used effectively. Qualitative data collection offers the strength of exploring ambivalence and investigating the reasons for views, but not necessarily their prevalence in wider society. The inherent value of a qualitative method, such as focus groups, therefore lies in its ability to uncover new information. This contrasts with a quantitative approach to simply 'measuring' public opinion on a topic about which participants may have little prior knowledge. We discuss a number of challenges including: appropriate roles for embedded social scientists and the intricacies of doing upstream engagement as well as some of the design issues and limitations associated with the focus group method.

  19. Handbook of nuclear safeguards measurement methods

    International Nuclear Information System (INIS)

    Rogers, D.R.

    1983-09-01

    This handbook is intended to be a guide to the selection of methods for meeting specific measurement requirements. The information was compiled from a survey of production facilities, the literature, and current exchange programs. The survey included bulk measurements, chemical assay, sampling techniques, isotopic measurements, passive NDA, and active NDA

  20. Methods of measurement in epidemiology: sedentary behaviour

    OpenAIRE

    Atkin, Andrew James; Gorely, Trish; Clemes, Stacy A; Yates, Thomas; Edwardson, Charlotte; Brage, Soren; Salmon, Jo; Marshall, Simon J; Biddle, Stuart JH

    2012-01-01

    Background: Research examining sedentary behaviour as a potentially independent risk factor for chronic disease morbidity and mortality has expanded rapidly in recent years. Methods: We present a narrative overview of the sedentary behaviour measurement literature. Subjective and objective methods of measuring sedentary behaviour suitable for use in population-based research with children and adults are examined. The validity and reliability of each method is considered, gaps in...

  1. Comparison of the Omron HEM-713C automated blood pressure monitor with a standard ausculatory method using a mercury manometer.

    Science.gov (United States)

    Mufunda, J; Sparks, B; Chifamba, J; Dakwa, C; Matenga, J A; Adams, J M; Sparks, H V

    1996-08-01

    To compare the Omron HEM-713C automated blood pressure machine with the standard ausculatory method using a mercury manometer. Blood pressures of randomly selected subjects were measured using both the Omron HEM-713C and the mercury manometer. Dombotombo surburb in Marondera, Zimbabwe. One hundred and sixteen subjects 25 years and above (47 males and 69 females) randomly selected in Marondera. Systolic blood pressure and diastolic blood pressure. The Omron HEM-713C passed with a grade B for both systolic and diastolic blood pressures when using the British Hypertension Society protocol. It also passed both systolic and diastolic criteria for Association of the Advancement of Medical Instrumentation. The Omron HEM-713C compares well with the standard mercury manometer, we therefore recommend its use in both research and clinical applications which require blood pressure measurements.

  2. An experimental method for detecting blood splatter from retractable phlebotomy and intravascular devices.

    Science.gov (United States)

    Haiduven, Donna; Applegarth, Shawn; Shroff, Miloni

    2009-03-01

    This study was designed to evaluate the safety of retractable intravascular devices in terms of their potential to produce blood splatter. A method for measuring this blood splatter designed by the research team was used to evaluate 3 specific intravascular devices. Scientific filters were positioned around the retraction mechanisms of the devices and weighed with an analytical scale, both before and after activation, in a simulated vein containing mock venous blood. The difference in filter mass was used as the primary unit of analysis to detect blood splatter. In addition, the filters were visually inspected for the presence or absence of blood. A paired t-test revealed significant differences in the prefilter and postfilter groups for 2 of the 3 devices tested (P blood was detected on 23% to 40% of the scientific filters for 2 of the devices. Our findings indicate a potential for bloodborne pathogen exposure with the use of intravascular devices with a retractable mechanism. This experiment may serve as a model in the design and implementation of future sharps device evaluation protocols to validate the threat of bloodborne pathogen exposure.

  3. Association of adiposity measures with blood lipids and blood pressure in children aged 8-11 years.

    Science.gov (United States)

    Vizcaíno, Vicente Martínez; Aguilar, Fernando Salcedo; Martínez, Montserrat Solera; López, Mairena Sánchez; Gutiérrez, Ricardo Franquelo; Rodríguez-Artalejo, Fernando

    2007-09-01

    To examine the association of body mass index (BMI), triceps skinfold thickness (TST) and percentage body fat (%BF) from bioelectrical impedance analysis (BIA) with blood lipids, systolic blood pressure (SBP) and diastolic blood pressure (DBP) in children. Cross-sectional study was conducted on 1280 schoolchildren aged 8-11 years from the Cuenca province (Spain). Data collection was conducted under standardized conditions, taking several measurements of each variable to enhance accuracy. Analyses were performed using age-adjusted correlation coefficients, and multiple linear regression adjusted for age, BMI, TST and %BF. Correlations between %BF and apolipoprotein (apo) B, total cholesterol, low-density lipoprotein cholesterol (LDL-c), total cholesterol/HDL-c ratio and DBP were higher than those for BMI and TST. In contrast, the correlations between BMI, and apo A-I and SBP were higher than those for %BF and TST. The results were similar across the sexes. The correlations between each of the three measures of body fatness, and blood lipids and blood pressure were highest in children with greatest BMI and %BF. When analyses were adjusted for the three body fatness measures, %BF showed stronger associations than did BMI or TST with blood lipids and blood pressure, with the exception of apo A-I and SBP, which were more closely associated with BMI. %BF from BIA is more strongly associated than either BMI or TST with most of the blood lipid fractions in schoolchildren aged 8-11 years.

  4. Measuring method for optical fibre sensors

    NARCIS (Netherlands)

    Lammerink, Theodorus S.J.; Fluitman, J.H.J.

    1984-01-01

    A new measuring method for the signal amplitude in intensity modulating fibre optic sensors is described. A reference signal is generated in the time domain. The method is insensitive for the sensitivity fluctuations of the light transmitter and the light receiver. The method is experimentally

  5. Measuring and communicating blood loss during obstetric hemorrhage.

    Science.gov (United States)

    Gabel, Kristi T; Weeber, Tracy A

    2012-01-01

    Accurate quantification of blood loss is an essential skill necessary to prevent maternal morbidity and mortality associated with obstetric hemorrhage. Visual estimation of blood has been consistently shown to be extremely inaccurate. The nurse plays a pivotal role in quantifying blood loss after birth, recognizing triggers, mobilizing needed interventions, and providing essential communication. © 2012 AWHONN, the Association of Women's Health, Obsteric and Neonatal Nurses.

  6. 75 FR 22813 - Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred Because of...

    Science.gov (United States)

    2010-04-30

    ... blood components intended for transfusion, with recommendations for a requalification method or process...] Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred Because of Reactive Test... availability of a document entitled ``Guidance for Industry: Requalification Method for Reentry of Blood Donors...

  7. Donating blood for research: a potential method for enhancing customer satisfaction of permanently deferred blood donors.

    Science.gov (United States)

    Waller, Daniel; Thijsen, Amanda; Garradd, Allira; Hayman, Jane; Smith, Geoff

    2017-01-01

    Each year, a large number of individuals in Australia are deferred from donating blood. A deferral may have a negative impact on donor satisfaction and subsequent word-of-mouth communication. The Australian Red Cross Blood Service (the Blood Service) is, therefore, investigating options for managing service interactions with deferred donors to maintain positive relationships. While public research institutes in Australia have established independent research donor registries, other countries provide programmes allowing deferred donors to donate blood for research via blood collection agencies. This study examined attitudes towards donating blood for research use in a sample of permanently deferred Australian donors. Donors permanently deferred because of a risk of variant Creutzfeldt-Jakob disease (n=449) completed a postal survey that examined attitudes towards research donation. The majority of participants were interested in donating blood for research (96%), and joining a registry of research donors (93%). Participants preferred to donate for transfusion or clinical research, and were willing to travel large distances. Results indicated that positive attitudes towards the Blood Service would be extended if the opportunity to donate blood was provided. These findings indicate a desire for continued engagement with the Blood Service despite deferral. Donating blood for research is a potential way of maintaining positive relationships with permanently deferred donors which also benefits the health research community. Through maintaining positive relationships with deferred donors, positive word-of-mouth activity can be stimulated. Further work is needed to determine the feasibility of implementing research donation through the Blood Service in Australia.

  8. Laser speckle imaging of rat retinal blood flow with hybrid temporal and spatial analysis method

    Science.gov (United States)

    Cheng, Haiying; Yan, Yumei; Duong, Timothy Q.

    2009-02-01

    Noninvasive monitoring of blood flow in retinal circulation will reveal the progression and treatment of ocular disorders, such as diabetic retinopathy, age-related macular degeneration and glaucoma. A non-invasive and direct BF measurement technique with high spatial-temporal resolution is needed for retinal imaging. Laser speckle imaging (LSI) is such a method. Currently, there are two analysis methods for LSI: spatial statistics LSI (SS-LSI) and temporal statistical LSI (TS-LSI). Comparing these two analysis methods, SS-LSI has higher signal to noise ratio (SNR) and TSLSI is less susceptible to artifacts from stationary speckle. We proposed a hybrid temporal and spatial analysis method (HTS-LSI) to measure the retinal blood flow. Gas challenge experiment was performed and images were analyzed by HTS-LSI. Results showed that HTS-LSI can not only remove the stationary speckle but also increase the SNR. Under 100% O2, retinal BF decreased by 20-30%. This was consistent with the results observed with laser Doppler technique. As retinal blood flow is a critical physiological parameter and its perturbation has been implicated in the early stages of many retinal diseases, HTS-LSI will be an efficient method in early detection of retina diseases.

  9. Statistical modelling of measurement errors in gas chromatographic analyses of blood alcohol content.

    Science.gov (United States)

    Moroni, Rossana; Blomstedt, Paul; Wilhelm, Lars; Reinikainen, Tapani; Sippola, Erkki; Corander, Jukka

    2010-10-10

    Headspace gas chromatographic measurements of ethanol content in blood specimens from suspect drunk drivers are routinely carried out in forensic laboratories. In the widely established standard statistical framework, measurement errors in such data are represented by Gaussian distributions for the population of blood specimens at any given level of ethanol content. It is known that the variance of measurement errors increases as a function of the level of ethanol content and the standard statistical approach addresses this issue by replacing the unknown population variances by estimates derived from large sample using a linear regression model. Appropriate statistical analysis of the systematic and random components in the measurement errors is necessary in order to guarantee legally sound security corrections reported to the police authority. Here we address this issue by developing a novel statistical approach that takes into account any potential non-linearity in the relationship between the level of ethanol content and the variability of measurement errors. Our method is based on standard non-parametric kernel techniques for density estimation using a large database of laboratory measurements for blood specimens. Furthermore, we address also the issue of systematic errors in the measurement process by a statistical model that incorporates the sign of the error term in the security correction calculations. Analysis of a set of certified reference materials (CRMs) blood samples demonstrates the importance of explicitly handling the direction of the systematic errors in establishing the statistical uncertainty about the true level of ethanol content. Use of our statistical framework to aid quality control in the laboratory is also discussed. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Methods of measuring residual stresses in components

    International Nuclear Information System (INIS)

    Rossini, N.S.; Dassisti, M.; Benyounis, K.Y.; Olabi, A.G.

    2012-01-01

    Highlights: ► Defining the different methods of measuring residual stresses in manufactured components. ► Comprehensive study on the hole drilling, neutron diffraction and other techniques. ► Evaluating advantage and disadvantage of each method. ► Advising the reader with the appropriate method to use. -- Abstract: Residual stresses occur in many manufactured structures and components. Large number of investigations have been carried out to study this phenomenon and its effect on the mechanical characteristics of these components. Over the years, different methods have been developed to measure residual stress for different types of components in order to obtain reliable assessment. The various specific methods have evolved over several decades and their practical applications have greatly benefited from the development of complementary technologies, notably in material cutting, full-field deformation measurement techniques, numerical methods and computing power. These complementary technologies have stimulated advances not only in measurement accuracy and reliability, but also in range of application; much greater detail in residual stresses measurement is now available. This paper aims to classify the different residual stresses measurement methods and to provide an overview of some of the recent advances in this area to help researchers on selecting their techniques among destructive, semi destructive and non-destructive techniques depends on their application and the availabilities of those techniques. For each method scope, physical limitation, advantages and disadvantages are summarized. In the end this paper indicates some promising directions for future developments.

  11. Contemporary methods of body composition measurement.

    Science.gov (United States)

    Fosbøl, Marie Ø; Zerahn, Bo

    2015-03-01

    Reliable and valid body composition assessment is important in both clinical and research settings. A multitude of methods and techniques for body composition measurement exist, all with inherent problems, whether in measurement methodology or in the assumptions upon which they are based. This review is focused on currently applied methods for in vivo measurement of body composition, including densitometry, bioimpedance analysis, dual-energy X-ray absorptiometry, computed tomography (CT), magnetic resonance techniques and anthropometry. Multicompartment models including quantification of trace elements by in vivo neutron activation analysis, which are regarded as gold standard methods, are also summarized. The choice of a specific method or combination of methods for a particular study depends on various considerations including accuracy, precision, subject acceptability, convenience, cost and radiation exposure. The relative advantages and disadvantages of each method are discussed with these considerations in mind. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Contemporary methods of body composition measurement

    DEFF Research Database (Denmark)

    Fosbøl, Marie Ø; Zerahn, Bo

    2015-01-01

    Reliable and valid body composition assessment is important in both clinical and research settings. A multitude of methods and techniques for body composition measurement exist, all with inherent problems, whether in measurement methodology or in the assumptions upon which they are based. This re...... and radiation exposure. The relative advantages and disadvantages of each method are discussed with these considerations in mind........ This review is focused on currently applied methods for in vivo measurement of body composition, including densitometry, bioimpedance analysis, dual-energy X-ray absorptiometry, computed tomography (CT), magnetic resonance techniques and anthropometry. Multicompartment models including quantification of trace...

  13. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women....... In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small...

  14. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women......A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between....... In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small...

  15. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the

  16. Development of automatic blood extraction device with a micro-needle for blood-sugar level measurement

    Science.gov (United States)

    Kawanaka, Kaichiro; Uetsuji, Yasutomo; Tsuchiya, Kazuyoshi; Nakamachi, Eiji

    2008-12-01

    In this study, a portable type HMS (Health Monitoring System) device is newly developed. It has features 1) puncturing a blood vessel by using a minimally invasive micro-needle, 2) extracting and transferring human blood and 3) measuring blood glucose level. This miniature SMBG (Self-Monitoring of Blood Glucose) device employs a syringe reciprocal blood extraction system equipped with an electro-mechanical control unit for accurate and steady operations. The device consists of a) a disposable syringe unit, b) a non-disposable body unit, and c) a glucose enzyme sensor. The syringe unit consists of a syringe itself, its cover, a piston and a titanium alloy micro-needle, whose inner diameter is about 100µm. The body unit consists of a linear driven-type stepping motor, a piston jig, which connects directly to the shaft of the stepping motor, and a syringe jig, which is driven by combining with the piston jig and slider, which fixes the syringe jig. The required thrust to drive the slider is designed to be greater than the value of the blood extraction force. Because of this driving mechanism, the automatic blood extraction and discharging processes are completed by only one linear driven-type stepping motor. The experimental results using our miniature SMBG device was confirmed to output more than 90% volumetric efficiency under the driving speed of the piston, 1.0mm/s. Further, the blood sugar level was measured successfully by using the glucose enzyme sensor.

  17. Methods of Measurement in epidemiology: Sedentary Behaviour

    Science.gov (United States)

    Atkin, Andrew J; Gorely, Trish; Clemes, Stacy A; Yates, Thomas; Edwardson, Charlotte; Brage, Soren; Salmon, Jo; Marshall, Simon J; Biddle, Stuart JH

    2012-01-01

    Background Research examining sedentary behaviour as a potentially independent risk factor for chronic disease morbidity and mortality has expanded rapidly in recent years. Methods We present a narrative overview of the sedentary behaviour measurement literature. Subjective and objective methods of measuring sedentary behaviour suitable for use in population-based research with children and adults are examined. The validity and reliability of each method is considered, gaps in the literature specific to each method identified and potential future directions discussed. Results To date, subjective approaches to sedentary behaviour measurement, e.g. questionnaires, have focused predominantly on TV viewing or other screen-based behaviours. Typically, such measures demonstrate moderate reliability but slight to moderate validity. Accelerometry is increasingly being used for sedentary behaviour assessments; this approach overcomes some of the limitations of subjective methods, but detection of specific postures and postural changes by this method is somewhat limited. Instruments developed specifically for the assessment of body posture have demonstrated good reliability and validity in the limited research conducted to date. Miniaturization of monitoring devices, interoperability between measurement and communication technologies and advanced analytical approaches are potential avenues for future developments in this field. Conclusions High-quality measurement is essential in all elements of sedentary behaviour epidemiology, from determining associations with health outcomes to the development and evaluation of behaviour change interventions. Sedentary behaviour measurement remains relatively under-developed, although new instruments, both objective and subjective, show considerable promise and warrant further testing. PMID:23045206

  18. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  19. Image-Method Gain Measurement With Mismatch

    Science.gov (United States)

    Lee, Richard Q.; Baddour, Maurice F.

    1988-01-01

    New formula accounts for multiple reflections. In image method antenna placed facing its image in reflecting plane. Power transmitted by antenna and portion of transmitted power received by antenna after reflection from plane measured at various distances R.

  20. Heat transfer measurements with TOIRT method

    Science.gov (United States)

    Solnař, S.; Petera, K.; Dostál, M.; Jirout, T.

    Temperature Oscillation Infra-Red Thermography (TOIRT) method was used to measure heat transfer coefficients between a at surface and a confined impinging jet generated by an impeller in a difusor and baffled vessel. The TOIRT method is based on measuring a phase-lag between the oscillating heat flux applied to the heat transfer surface and the surface temperature response using a contactless infra-red camera. The phase lag is in a direct relationship with the heat transfer coefficient.

  1. Microcantilever based disposable viscosity sensor for serum and blood plasma measurements.

    Science.gov (United States)

    Cakmak, Onur; Elbuken, Caglar; Ermek, Erhan; Mostafazadeh, Aref; Baris, Ibrahim; Erdem Alaca, B; Kavakli, Ibrahim Halil; Urey, Hakan

    2013-10-01

    This paper proposes a novel method for measuring blood plasma and serum viscosity with a microcantilever-based MEMS sensor. MEMS cantilevers are made of electroplated nickel and actuated remotely with magnetic field using an electro-coil. Real-time monitoring of cantilever resonant frequency is performed remotely using diffraction gratings fabricated at the tip of the dynamic cantilevers. Only few nanometer cantilever deflection is sufficient due to interferometric sensitivity of the readout. The resonant frequency of the cantilever is tracked with a phase lock loop (PLL) control circuit. The viscosities of liquid samples are obtained through the measurement of the cantilever's frequency change with respect to a reference measurement taken within a liquid of known viscosity. We performed measurements with glycerol solutions at different temperatures and validated the repeatability of the system by comparing with a reference commercial viscometer. Experimental results are compared with the theoretical predictions based on Sader's theory and agreed reasonably well. Afterwards viscosities of different Fetal Bovine Serum and Bovine Serum Albumin mixtures are measured both at 23°C and 37°C, body temperature. Finally the viscosities of human blood plasma samples taken from healthy donors are measured. The proposed method is capable of measuring viscosities from 0.86 cP to 3.02 cP, which covers human blood plasma viscosity range, with a resolution better than 0.04 cP. The sample volume requirement is less than 150 μl and can be reduced significantly with optimized cartridge design. Both the actuation and sensing are carried out remotely, which allows for disposable sensor cartridges. Copyright © 2013. Published by Elsevier Inc.

  2. Diagnostic accuracy of manual office blood pressure measurement in ambulatory hypertensive patients in Korea.

    Science.gov (United States)

    Kim, Sehun; Park, Jin Joo; Lee, Seung-Ah; Cho, Youngjin; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Cho, Young-Seok; Youn, Tae-Jin; Cho, Goo-Yeong; Chae, In-Ho; Lee, Hae-Young; Shin, Jinho; Park, Sungha; Choi, Dong-Ju

    2018-01-01

    Currently, office blood pressure (OBP) is the most widely used method of measuring blood pressure (BP) in daily clinical practice. However, data on the diagnostic accuracy of OBP in reference to ambulatory blood pressure (ABP) are scarce in Korea. In retrospective and prospective cohorts, manual OBP and ABP measurements were compared among ambulatory hypertensive patients. Hypertension was defined as systolic OBP ≥ 140 mmHg and/or diastolic OBP ≥ 90 mmHg, and systolic ABP ≥ 130 mmHg and/or diastolic ABP ≥ 80 mmHg. In the retrospective cohort (n = 903), the mean OBP1 (before ABP measurement) was higher than ABP in both systolic (138 ± 17 mmHg vs. 123 ± 13 mmHg, p higher false negative results (masked or under-treated hypertension) than did female patients (26.1% vs. 17.8%, p = 0.003), whereas female patients had a higher false positive rate (white-coat or over-treated hypertension) than did male patients (28.7% vs. 15.2%, p accuracy of manual OBP is low in reference to ABP. Men and women have different patterns of discordance. These findings indicate that management of hypertensive patients with manual OBP measurements may be suboptimal and encourages the use of ABP in ambulatory hypertensive patients.

  3. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    increased when blood samples were stored for a period of time before the centrifugation, for certain cytokines more than 1000 fold compared to serum and plasma isolated and frozen immediately after venepuncture. The concentrations in serum generally increased more than in plasma. The measurable......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7...

  4. Noise thermometry - a new temperature measuring method

    International Nuclear Information System (INIS)

    Brixy, H.; Hecker, R.; Rittinghaus, K.F.

    1975-01-01

    The thermal Johnson-Niquist noise is the basis of noise thermometry. This temperature measuring method is, e.g., of interest insofar as the noise thermometer gives absolute values as a primary thermometer and is in principle extensively independent of environmental influences and material properties. The resistance values of the measuring probe are about 10 Ohm to a few kOhm. The demands of electronics are high, the self-noise of the measuring apparatus must be as small as possible; a comparative measuring method is advantageous. 1 to 2,500 K are given as a possible temperature range. An accuracy of 0.1% could be achieved in laboratory measurements. Temperature measurements to be used in operation in a few nuclear reactors are mentioned. (HP/LH) [de

  5. A new method to measure vaginal sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. To develop a new method to measure vaginal sensibility. We developed a technique to measure the

  6. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  7. A New Method to Measure Vaginal Sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Introduction: Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. Aims: To develop a new method to measure vaginal sensibility. Methods: We

  8. Refractive index measurement based on confocal method

    Science.gov (United States)

    An, Zhe; Xu, XiPing; Yang, JinHua; Qiao, Yang; Liu, Yang

    2017-10-01

    The development of transparent materials is closed to optoelectronic technology. It plays an increasingly important role in various fields. It is not only widely used in optical lens, optical element, optical fiber grating, optoelectronics, but also widely used in the building material, pharmaceutical industry with vessel, aircraft windshield and daily wear glasses.Regard of solving the problem of refractive index measurement in optical transparent materials. We proposed that using the polychromatic confocal method to measuring the refractive index of transparent materials. In this article, we describes the principle of polychromatic confocal method for measuring the refractive index of glass,and sketched the optical system and its optimization. Then we establish the measurement model of the refractive index, and set up the experimental system. In this way, the refractive index of the glass has been calibrated for refractive index experiment. Due to the error in the experimental process, we manipulated the experiment data to compensate the refractive index measurement formula. The experiment taking the quartz glass for instance. The measurement accuracy of the refractive index of the glass is +/-1.8×10-5. This method is more practical and accurate, especially suitable for non-contact measurement occasions, which environmental requirements is not high. Environmental requirements are not high, the ordinary glass production line up to the ambient temperature can be fully adapted. There is no need for the color of the measured object that you can measure the white and a variety of colored glass.

  9. Endotoxin level measurement in hemodialysis biofilm using "the whole blood assay".

    Science.gov (United States)

    Marion-Ferey, Karine; Leid, Jeff G; Bouvier, Ghislaine; Pasmore, Mark; Husson, Gilles; Vilagines, Rolland

    2005-06-01

    Biofilms have been found on the inner surface of silicone tubing inside dialysis machines. Endotoxin releasing from those biofilms increases the bioincompatibility of dialysis liquids and leads to long-term inflammatory complications among dialysis patients. Endotoxin measurement is recommended for the control of dialysis liquids. This article describes the use of a new method, the Whole Blood Assay (WBA), for endotoxin quantification in dialysis biofilms. Biofilms were suspended in sterile water by scraping the tubing samples. Diluted blood samples from healthy donors were stimulated overnight with the contaminated suspension. Stimulated mononuclear cells released IL-1beta in response to endotoxins. IL-1beta level was then measured using an ultrasensitive ELISA method. We demonstrated a semilogarithmic model in which the optical densities measured after the ELISA assay increases linearly with the levels of endotoxin. This model allowed the determination of the amount of endotoxins in biofilm samples with a detection limit of 0.032 EU/mL. Most of the time, the amounts of endotoxin measured by the WBA were higher than those measured by the Limulus Amoebocyte Lysate (LAL) assay. This study suggested the presence of "endotoxin-like" compounds different from the lipopolysaccharides that are not detected by the LAL assay. We concluded that the LAL is necessary but insufficient to have a representative quantification of endotoxins that could be hazardous to patient health.

  10. Absolute method of measuring magnetic susceptibility

    Science.gov (United States)

    Thorpe, A.; Senftle, F.E.

    1959-01-01

    An absolute method of standardization and measurement of the magnetic susceptibility of small samples is presented which can be applied to most techniques based on the Faraday method. The fact that the susceptibility is a function of the area under the curve of sample displacement versus distance of the magnet from the sample, offers a simple method of measuring the susceptibility without recourse to a standard sample. Typical results on a few substances are compared with reported values, and an error of less than 2% can be achieved. ?? 1959 The American Institute of Physics.

  11. Venostasis test as a method of choice to evaluate blood fibrinolytic capacity during third molar surgery.

    Science.gov (United States)

    Dimova, C; Evrosimovska, B; Kovacevska, I

    2012-01-01

    The aim of our research was to evaluate the fibrinolytic capacity during oral surgical interventions - operative extraction of semi-impacted third molars having caused blood fibrinolysis activity. With the intention of establishing the condition of the blood vessels' endothelium before oral surgical interventions, the influence of surgical procedures upon the endothelium, and the response of the endothelium after interventions, the venostasis test (venous stasis) was conducted in all the subjects. This test measures the global fibrinolytic activity of the plasma, caused by anoxia. In order to realize the aim, the first blood sample was taken before the beginning of the test, and then the indicated oral surgical intervention was performed. Immediately after the completion of the surgery, the venostasis test was carried out, lasting for five minutes, and right after the test a second sample of blood was taken. Using the method of fibrin plates, the level of the activators and inhibitors of the plasminogen was established afterwards. The average values of the pro activators and inhibitors of fibrinolysis from the venostasis test, in all subjects, showed increased values compared to the same ones in the control group, in all researched relations. Statistically, a significant difference was established after interventions were performed. These findings support the fact of possible damage to the blood vessels' endothelium and a change of the fibrinolytic capacity in the perioperative period of third molar surgery.

  12. Method of orthogonally splitting imaging pose measurement

    Science.gov (United States)

    Zhao, Na; Sun, Changku; Wang, Peng; Yang, Qian; Liu, Xintong

    2018-01-01

    In order to meet the aviation's and machinery manufacturing's pose measurement need of high precision, fast speed and wide measurement range, and to resolve the contradiction between measurement range and resolution of vision sensor, this paper proposes an orthogonally splitting imaging pose measurement method. This paper designs and realizes an orthogonally splitting imaging vision sensor and establishes a pose measurement system. The vision sensor consists of one imaging lens, a beam splitter prism, cylindrical lenses and dual linear CCD. Dual linear CCD respectively acquire one dimensional image coordinate data of the target point, and two data can restore the two dimensional image coordinates of the target point. According to the characteristics of imaging system, this paper establishes the nonlinear distortion model to correct distortion. Based on cross ratio invariability, polynomial equation is established and solved by the least square fitting method. After completing distortion correction, this paper establishes the measurement mathematical model of vision sensor, and determines intrinsic parameters to calibrate. An array of feature points for calibration is built by placing a planar target in any different positions for a few times. An terative optimization method is presented to solve the parameters of model. The experimental results show that the field angle is 52 °, the focus distance is 27.40 mm, image resolution is 5185×5117 pixels, displacement measurement error is less than 0.1mm, and rotation angle measurement error is less than 0.15°. The method of orthogonally splitting imaging pose measurement can satisfy the pose measurement requirement of high precision, fast speed and wide measurement range.

  13. COMPANY PERFORMANCE MEASUREMENT AND REPORTING METHODS

    Directory of Open Access Journals (Sweden)

    Nicu Ioana Elena

    2012-12-01

    Full Text Available One of the priorities of economic research has been and remains the re-evaluation of the notion of performance and especially exploring and finding some indicators that would reflect as accurately as possible the subtleties of the economic entity. The main purpose of this paper is to highlight the main company performance measurement and reporting methods. Performance is a concept that raises many question marks concerning the most accurate or the best method of reporting the performance at the company level. The research methodology has aimed at studying the Romanian and foreign specialized literature dealing with the analyzed field, studying magazines specialized on company performance measurement. If the financial performance measurement indicators are considered to offer an accurate image of the situation of the company, the modern approach through non-financial indicators offers a new perspective upon performance measurement, which is based on simplicity. In conclusion, after the theoretical study, I have noticed that the methods of performance measurement, reporting and interpretation are various, the opinions regarding the best performance measurement methods are contradictive and the companies prefer resorting to financial indicators that still play a more important role in the consolidation of the company performance measurement than the non-financial indicators do.

  14. Radioimmunoassay of alpha-foetoprotein in the eluate of dried blood. A method for antenatal screening of neural tube defects

    International Nuclear Information System (INIS)

    Travert, G.; Herlicoviez, M.; Laroche, D.

    1979-01-01

    A radioimmunoassay for alpha-foetoprotein (AFP) in dried blood spots is reported. The main technical characteristics (reproducibility, sensitivity, recovery of exogenous AFP added and AFP stability in dried blood) are evaluated. They indicate that this method is feasible and well adapted to AFP measurement during pregnancy. AFP determination in maternal serum allows early detection of at least 80% of neural tube defects. The use of dried blood spots as samples for AFP assay makes our method a possible mass screening test for these malformations, which occur with an incidence of 12 for 10,000 [fr

  15. Level of Mercury Manometer With Respect to Heart: Does it Affect Blood Pressure Measurement?

    Science.gov (United States)

    Kapoor, Raj; Roy, V K; Manna, S; Bhattacharjee, M

    2015-01-01

    Measurement of blood pressure is an integral part of clinical examination. Over the years various types of instruments have been used to measure blood pressure but till date the mercury sphygmomanometer is regarded as the gold standard. However, there is a myth prevalent among health professionals regarding the level of the manometer in relation to heart at the time of measuring of blood pressure. Many professionals insist that it has to be placed at the level of the heart. We argue that the limb from which pressure is measured must be at the heart level rather than the manometer. We conducted a study in which we measured the blood pressure in adults by placing the manometer at three different levels with respect to the heart. The values of blood pressure obtained at all levels were similar and did not show any statistically significant difference. We therefore conclude that the level of sphygmomanometer per se does not affect blood pressure measurement.

  16. Differences in blood pressure measurements in the forearm and upper arm of obese otherwise healthy first year medical students

    Directory of Open Access Journals (Sweden)

    Suganthi V, Navin Rajaratnam, Suzanne Maria D’cruz

    2014-07-01

    Full Text Available Background: The prevalence of obesity is increasing in Indian youth and obesity is associated with complications like systemic hypertension. Often, due to the non-availability of appropriate sized cuffs, standard cuff bladders are used to measure blood pressure in the forearms of obese young adults. Aim: To compare the upper arm arterial blood pressure measured using an appropriate cuff with the forearm arterial blood pressure measured using a standard cuff and conventional sphygmomanometry in obese otherwise healthy first year medical students. Materials and Methods: Blood pressure was measured in 27 obese otherwise healthy first year medical students after five minutes of rest using a mercury sphygmomanometer with the subjects seated and the arm and forearm at heart level, using an appropriate sized cuff for the upper arm according to American Heart Association standards and a standard cuff for the fore arm. Results: A statistically significant difference in both systolic [t-test (paired = -6.921; df = 26; sig = .000 (2- tailed] and diastolic blood pressure [t-test (paired = -8.508; df = 26; sig = .000 (2- tailed] was found, with the blood pressure readings being higher in the forearm. The correlations between upper arm and forearm systolic and diastolic blood pressure were 0.785 (p = .000 and 0.870 (p = .000. Conclusion: Both systolic and diastolic blood pressure measurements were significantly higher in the forearm. Further studies with larger sample size should be conducted to confirm that forearm blood pressure measurements using standard cuff bladders cannot be considered equal to upper arm measurements made using an appropriate sized cuff in all young obese individuals

  17. Blood flow measurement of brain tumor by sup 123 I-IMP using 3-heads rotating gamma camera SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Makiko; Yui, Nobuharu; Togawa, Takashi; Namba, Hiroki; Kinoshita, Fujimi; Koakutsu, Masaki (Chiba Cancer Center (Japan)); Minoshima, Satoshi; Uchida, Yoshitaka; Arimizu, Noboru

    1991-12-01

    Using 3-heads rotating gamma camera SPECT system, regional blood flow was measured from the super-early image obtained 4 to 6 minutes after the intravenous injection of {sup 123}I-IMP on 11 patients with various brain tumors. Two cases of olfactory groove meningioma and malignant astrocytoma showed significantly high {sup 123}I-IMP uptake by the lesion visualized by MRI compared to the uptake by normal brain cortex on super-early image but {sup 123}I-IMP uptake by the tumor decreased on early image. In both cases, blood flow of the tumor measured from super-early image showed values much higher than those of normal brain cortex. It was thought that usual correction method based on early image did not correctly represent the blood flow of the lesion but that the present method based on super-early image could show the increase of blood flow of the tumor. (author).

  18. Track detection methods of radium measurements

    International Nuclear Information System (INIS)

    Somogyi, G.

    1986-06-01

    The principles of tack formation and processing including the description of etching and etch-track evaluation for the preferably used plastic track detectors are discussed. Measuring methods to determine 226 Ra activity based either on the mapping of alpha-decaying elements in the complete U-Ra series by alpha-radiography, or on the measurement of uranium alone by neutron induced fissionography, or on the alpha-decay measurement of 222 Rn, the first daughter element of radium, and finally on the measurement of alpha-tracks originating from radium itself, which is separated from its parent nuclides are described in detail. (V.N.)

  19. Measurement error models, methods, and applications

    CERN Document Server

    Buonaccorsi, John P

    2010-01-01

    Over the last 20 years, comprehensive strategies for treating measurement error in complex models and accounting for the use of extra data to estimate measurement error parameters have emerged. Focusing on both established and novel approaches, ""Measurement Error: Models, Methods, and Applications"" provides an overview of the main techniques and illustrates their application in various models. It describes the impacts of measurement errors on naive analyses that ignore them and presents ways to correct for them across a variety of statistical models, from simple one-sample problems to regres

  20. MRI-based blood oxygen saturation measurements in infants and children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Nield, Lynne E.; Valsangiacomo, Emanuela R.; Hornberger, Lisa K. [Department of Paediatrics and Division of Cardiology, Hospital for Sick Children, Toronto, ON (Canada); Qi, Xiuling; Wright, Graham A. [Department of Medical Biophysics, Sunnybrook Health Sciences Center, University of Toronto, Toronto, ON (Canada); Yoo, Shi-Joon [Department of Diagnostic Imaging, Hospital for Sick Children, University of Toronto School of Medicine, Toronto, ON (Canada)

    2002-07-01

    Background: Vessel oxygen saturation can be determined with MR oximetry using an in vivo measurement of signal decay (T2) and the calibration curve relating T2 to blood oxygen saturation (%HbO{sub 2}), where: 1/T2=1/T2O+K (1-%HbO{sub 2}/100){sup 2} and K is a constant parameter which correlates with measured fibrinogen levels. The ability to noninvasively measure %HbO{sub 2} in cardiac chambers and vessels has enormous potential in children with congenital heart disease (CHD). Objective: The purpose of the study was to prospectively characterize the T2-%HbO{sub 2} relationship in infants where T2-%HbO{sub 2} is the realtionship between T2 and %HbO{sub 2} (blood oxygen saturation) expressed by the equation given above, and to determine whether adult values for K and T2O (where T2O is the T2 of fully oxygenated blood) can be extrapolated to pediatric patients with CHD. A second objective was to apply this method to calculate the %HbO{sub 2} in vivo using MR imaging in infants with CHD. Materials and methods: Fifteen patients with CHD undergoing cardiac catheterization (9 male; 6 female), median age 8 months, were recruited for the calibration study. T2O and K were measured directly from blood samples, compared with the values estimated from adult population statistics, and plotted against hematocrit and fibrinogen, respectively. In four studies of infants with CHD, T2 measurements were converted to %HbO{sub 2} using the calibration curve. Results: The T2-%HbO{sub 2} relationship in infants correlated with the adult calibration statistics (1/T2O vs. hematocrit, r=0.77; K vs. fibrinogen, r=0.61). Our initial in vivo studies demonstrated that the MR oximetry reflected the expected oxygen saturations. Conclusion: Adult values for T2-%HbO{sub 2} calibration can be used to measure blood oxygen saturation in vivo in children with CHD. (orig.)

  1. Radionuclide assessment of peripheral hemodynamics: a new technique for measurement of forearm blood volume and flow

    Energy Technology Data Exchange (ETDEWEB)

    Todo, Y.; Tanimoto, M.; Yamamoto, T.; Iwasaki, T.

    1986-02-01

    A new peripheral hemodynamic measurement system using /sup 99m/Tc-labeled red blood cells has been developed. This method was carried out on 22 normal subjects, 29 with coronary artery disease, and two with dilated cardiomyopathy. Peripheral hemodynamic indices obtained from this method included forearm blood volume (FBV), venous capacity (FVC), venous capacity index (VCI), blood flow (FBF), and vascular resistance (FVR), and were compared with the central hemodynamic parameters of left ventricular filling pressure (LVFP), cardiac output (CO), and total systemic vascular resistance (TSVR) obtained with an invasive technique. The normal values were FBV 8.54 +/- 2.04 ml/100 ml; FVC 4.54 +/- 1.23 ml/100 ml; VCI 65.5 +/- 3.8%; FBF 4.26 +/- 0.56 ml/100 ml/min; and FVR 20.9 +/- 4.4 mmHg/ml/100 ml/min. These values were in good agreement with the values reported using conventional plethysmography. The 16 patients with congestive heart failure (NYHA Class II or III) showed significantly lower FBV, FVC, and FBF values and significantly higher VCI and FVR values than the healthy subjects. Capacitance vessel parameters (FBV, FVC, and VCI) and LVFP, FBF and CO, and FVR and TSVR each showed significant correlation; reproducibility was also good. The advantages of this method are (a) the detector does not come in contact with the region being measured; (b) it is possible to ascertain the absolute quantity of blood in the tissue; (c) extravasation of the plasma component can be ignored; and (d) data processing is simple.

  2. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  3. Development of radiochemical method of analysis of binding of tritium labeled drotaverine hydrochloride with human blood serum albumin

    International Nuclear Information System (INIS)

    Kim, A.A.; Djuraeva, G.T.; Shukurov, B.V.; Mavlyanov, I.R.

    2004-01-01

    Full text: The albumin, being a basic functional linkage of numerous endogenous and exogenous substances is the most important protein of blood plasma. At the diseases connected to liver disfunction, collected in blood metabolite reduce connecting ability of albumino. The aim of the present research was a development of radiochemical method of determination of ability of albumin to bind the tritium labeled preparation drotaverine hydrochloride (no - spa). We had developed a micromethod of definition of connecting ability of albumin, allowing to analyse 20 mkl of blood serum. The method consists in incubation of tritium labeled drotaverine hydrochloride with blood serum in vitro, the following fractionation of serum proteins by gel - filtration on a microcolumn with Sephadex G-25, and direct measurement of the radioactivity connected to fraction of proteins of blood serum. The method has been tested on a series of blood serum of control group of healthy people and on a series of blood serum of patients with hepatitis B. We received quantitative characteristics of binding of drotaverine hydrochloride with albumin of patients with hepatitis B. It was preliminary established that binding ability of serum albumin of children with various forms of acute virus hepatitis tends to decrease in comparison with group of the control. Advantage of the developed radiochemical method is high precision and the high sensitivity of detection of infringement of binding ability of albumin. Application of tritium labeled drotaverine hydrochloride allows to measure directly levels of binding of a preparation with albumin

  4. Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; van den Berg, Albert

    2004-01-01

    The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with

  5. Cerebral blood flow measured by positron emission tomography during normothermic cardiopulmonary bypass: An experimental porcine study

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Kjaergaard, Benedict; Alstrup, Aage Kristian Olsen

    2018-01-01

    min and, thereafter, all the pigs returned to 60 mL/kg/min for another 60 min. The MAP was measured continuously and the CBF was measured by positron emission tomography (PET) during spontaneous circulation and at each CPB pump flow after 30 min of steady state. Results: Two pigs were excluded due...... emission tomography (PET) using 15O-labelled water with no pharmacological interventions to maintain the MAP. Methods: Eight pigs (69-71 kg) were connected to normothermic CPB. After 60 minutes (min) with a CPB pump flow of 60 mL/kg/min, the pigs were changed to either 35 mL/kg/min or 47.5 mL/kg/min for 60......Background: Mean arterial blood pressure (MAP) and/or pump flow during normothermic cardiopulmonary bypass (CPB) are the most important factors of cerebral perfusion. The aim of this study was to explore the influence of CPB blood flow on cerebral blood flow (CBF) measured by dynamic positron...

  6. [Reliability of blood pressure measurements; comparison of an electronic meter and a mercury manometer in family practice].

    Science.gov (United States)

    van Doorn, B A; van der Does, E; Lubsen, J; Rijsterborgh, H

    1990-08-25

    The Riva-Rocci indirect method of measuring the blood pressure carries a number of sources of error. A report is presented of a study of the serviceability of an electronic blood pressure meter as compared with the conventional mercury manometer. Seventy-six paired measurements were carried out in patients selected at random using an electronic blood pressure meter and a mercury manometer meeting all Health Council requirements. The systematic error and the incidental error in both measuring procedures were compared. The differences found were so slight as to be negligible in practice. It is concluded that the electronic blood pressure meter in practice constitutes an acceptable substitute for the conventional mercury manometer.

  7. Fibrinogen measurements in plasma and whole blood: a performance evaluation study of the dry-hematology system.

    Science.gov (United States)

    Ogawa, Satoru; Tanaka, Kenichi A; Nakajima, Yasufumi; Nakayama, Yoshinobu; Takeshita, Jun; Arai, Masatoshi; Mizobe, Toshiki

    2015-01-01

    An accurate and rapid determination of fibrinogen level is important during hemorrhage to establish a timely hemostatic intervention. The accuracy of fibrinogen measurements may be affected by the specific methodology for its determination, fluid therapies, and anticoagulant agents. The dry-hematology method (DRIHEMATO®) is a novel approach to determine fibrinogen levels in plasma and whole blood based on thrombin-activated coagulation time. We hypothesized that plasma or whole blood fibrinogen level using the dry-hematology method would be similar to those measured with conventional plasma fibrinogen assays. Acquired hypofibrinogenemia was modeled by serial dilutions of blood samples obtained from 12 healthy volunteers. Citrated whole blood samples were diluted with either normal saline, 5% human albumin, or 6% hydroxyethyl starch to achieve 25%, 50%, and 75% volume replacement. The dry-hematology method, the Clauss method, the prothrombin time (PT)-derived method, determination of antigen levels, and thromboelastometric fibrin formation were compared in plasma or whole blood samples. The effect of heparin on each assay was examined (0 to 6 IU/mL). Comparisons of dry-hematology and other methods were also conducted using ex vivo samples obtained from cardiac surgical patients (n = 60). In plasma samples, there were no significant differences between dry-hematology and the Clauss method, while dry-hematology showed lower fibrinogen levels compared with PT-derived and antigen level methods. The dry-hematology method yielded acceptable concordance correlation coefficients (Pc) with the Clauss method, the PT-derived method, and fibrinogen antigen levels (Pc = 0.91-0.99). The type of diluents and heparin affected the results of the PT-derived method and thromboelastometric assay, but not the dry-hematology method. In cardiac surgical patients, the overall correlation in fibrinogen levels between dry-hematology and the other methods was comparable to the results from

  8. Risk Minimization Measures for Blood Screening HIV-1 Nucleic Acid Amplification Technique Assays in Germany

    Science.gov (United States)

    Chudy, Michael; Kress, Julia; Halbauer, Jochen; Heiden, Margarethe; Funk, Markus B.; Nübling, C. Micha

    2014-01-01

    Summary Background Several publications describe HIV-1 RNA false-negative results or viral load underquantitation associated with Communauté Européenne(CE)-marked qualitative or quantitative nucleic acid amplification technique (NAT) assays. 6 cases occurred during blood screening in Germany, with 2 of them causing HIV-1 transmissions to recipients of blood components. The implicated NAT assays were mono-target assays amplifying in different viral genome regions (gag or long terminal repeat). Methods Specimens characterized by HIV-1 NAT underquantitation or false-negative NAT results were comparatively investigated in CE-marked HIV-1 NAT systems of different design to identify potential reasons. The target regions of the viral nucleic acids were sequenced and these sequences compared to primers and probes of the assays. Potential risk minimization measures were considered for quantitative and blood-screening HIV-1 NAT systems. Results Nucleotide sequencing of the viral target region in cases of HIV-1 RNA underquantitation or false-negative test results revealed new HIV-1 variants that were mismatched with primers and probes used in some mono-target assays. So far, dualtarget NAT assays have not been associated with mismatch-based false-negative test results. From 2015, the Paul Ehrlich Institute will request HIV-1 NAT assays of dual-target design or an analogous solution for further reducing the risk in blood screening. Conclusion HIV differs from other blood-borne viruses with regard to its fast evolution of new viral variants. The evolution of new sequences is hardly predictable; therefore, NAT assays with only 1 target region appear to be more vulnerable to sequence variations than dual-target assays. The associated risk may be higher for HIV-1 NAT assays used for blood screening compared to quantitative assays used for monitoring HIV-1-infected patients. In HIV-1 screening NAT assays of dual-target design may adequately address the risk imposed by new HIV-1

  9. SAR measurement in MRI: an improved method

    Science.gov (United States)

    Romano, Rocco; Acernese, Fausto; Indovina, Pietro Luigi; Barone, Fabrizio

    2009-03-01

    During an MR procedure, the patient absorbs a portion of the transmitted RF energy, which may result in tissue heating and other adverse effects, such as alterations in visual, auditory and neural functions. The Specific Absorption Rate (SAR), in W/kg, is the RF power absorbed per unit mass of tissue and is one of the most important parameters related with thermal effects and acts as a guideline for MRI safety. Strict limits to the SAR levels are imposed by patient safety international regulations (CEI - EN 60601 - 2 - 33) and SAR measurements are required in order to verify its respect. The recommended methods for mean SAR measurement are quite problematic and often require a maintenance man intervention and long stop machine. For example, in the CEI recommended pulse energy method, the presence of a maintenance man is required in order to correctly connect the required instrumentation; furthermore, the procedure is complex and requires remarkable processing and calculus. Simpler are the calorimetric methods, also if in this case long acquisition times are required in order to have significant temperature variations and accurate heat capacity knowledge (CEI - EN 60601 - 2- 33). The phase transition method is a new method to measure SAR in MRI which has the advantages to be very simple and to overcome all the typical calorimetric method problems. It does not require in gantry temperature measurements, any specific heat or heat capacity knowledge, but only mass and time measurement. Furthermore, in this method, it is possible to show that all deposited SAR power can be considered acquired and measured.

  10. Ocular Blood Flow Measurements in Healthy White Subjects Using Laser Speckle Flowgraphy.

    Directory of Open Access Journals (Sweden)

    Nikolaus Luft

    Full Text Available To assess the feasibility and reliability of Laser Speckle Flowgraphy (LSFG to measure ocular perfusion in a sample of healthy white subjects and to elucidate the age-dependence of the parameters obtained.This cross-sectional study included 80 eyes of 80 healthy, non-smoking white subjects of Western European descent between 19 and 79 years of age. A commercial LSFG instrument was applied to measure ocular blood flow at the optic nerve head (ONH three successive times before and after pharmacological pupil dilation. The mean blur rate (MBR, a measure of relative blood flow velocity, was obtained for different regions of the ONH. Eight parameters of ocular perfusion derived from the pulse-waveform analysis of MBR including blowout time (BOT and falling rate (FR were also recorded.Artifact-free LSFG images meeting the quality criteria for automated image analysis were obtainable in 93.8% without pupil dilation and in 98.8% with pharmacological pupil dilation. Measurements of MBR showed excellent repeatability with intraclass correlation coefficients ≥ 0.937 and were barely affected by pupil dilation. The majority of pulse-waveform derived variables exhibited equally high repeatability. MBR-related blood flow indices exhibited significant age dependence (p<0.001. FR (r = 0.747, p<0.001 and BOT (r = -0.714, p<0.001 most strongly correlated with age.LSFG represents a reliable method for the quantitative assessment of ocular blood flow in white subjects. Our data affirms that the LSFG-derived variables FR and BOT may be useful biomarkers for age-related changes in ocular perfusion.

  11. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  12. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  13. Validation of continuous noninvasive arterial blood pressure measurements during general anesthesia

    NARCIS (Netherlands)

    Kalmar, A.F.; Vos, Jaap Jan; Weening, M.; Mooyaart, E.A.; Poterman, Marieke; Struys, Michel; Scheeren, Thomas

    2012-01-01

    Background:  Continuous invasive arterial blood pressure (IBP) monitoring remains the accepted gold standard for blood pressure monitoring because of its high accuracy. Several disadvantages of this method motivate the use of noninvasive intermittent blood pressure (NIBP) in most anesthesia cases

  14. Human performance assessment: methods and measures

    International Nuclear Information System (INIS)

    Andresen, Gisle; Droeivoldsmo, Asgeir

    2000-10-01

    The Human Error Analysis Project (HEAP) was initiated in 1994. The aim of the project was to acquire insights on how and why cognitive errors occur when operators are engaged in problem solving in advanced integrated control rooms. Since human error had not been studied in the HAlden Man-Machine LABoratory (HAMMLAB) before, it was also necessary to carry out research in methodology. In retrospect, it is clear that much of the methodological work is relevant to human-machine research in general, and not only to research on human error. The purpose of this report is, therefore, to give practitioners and researchers an overview of the methodological parts of HEAP. The scope of the report is limited to methods used throughout the data acquisition process, i.e., data-collection methods, data-refinement methods, and measurement methods. The data-collection methods include various types of verbal protocols, simulator logs, questionnaires, and interviews. Data-refinement methods involve different applications of the Eyecon system, a flexible data-refinement tool, and small computer programs used for rearranging, reformatting, and aggregating raw-data. Measurement methods involve assessment of diagnostic behaviour, erroneous actions, complexity, task/system performance, situation awareness, and workload. The report concludes that the data-collection methods are generally both reliable and efficient. The data-refinement methods, however, should be easier to use in order to facilitate explorative analyses. Although the series of experiments provided an opportunity for measurement validation, there are still uncertainties connected to several measures, due to their reliability still being unknown. (Author). 58 refs.,7 tabs

  15. On the Methods to Measure Powder Flow.

    Science.gov (United States)

    Tan, Geoffrey; Morton, David A V; Larson, Ian

    2015-01-01

    The flow of powders can often play a critical role in the manufacturing of pharmaceutical products. Many of these processes require good, consistent and predictable flow of powders to ensure continuous production of pharmaceutical dosages and to ensure their quality. Therefore, the flow of powders is of paramount importance to the pharmaceutical industry and thus the measuring and evaluating of powder flow is of utmost importance. At present, there are numerous methods in which the flow of powders can be measured. However, due to the complex and environment-dependent nature of powders, no one method exists that is capable of providing a complete picture of the behaviour of powders under dynamic conditions. Some of the most commonly applied methods to measure the flow of powders include: density indices, such as the Carr index and Hausner ratio, powder avalanching, the angle of repose (AOR), flow through an orifice, powder rheometry and shear cell testing.

  16. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    , and 30 days at the same temperatures. 27 inflammatory markers in serum and plasma and 25 markers in DBSS were measured by a previously validated multiplex sandwich immunoassay using Luminex xMAP technology. The measurable concentrations of several cytokines in serum and plasma were significantly......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... increased when blood samples were stored for a period of time before the centrifugation, for certain cytokines more than 1000 fold compared to serum and plasma isolated and frozen immediately after venepuncture. The concentrations in serum generally increased more than in plasma. The measurable...

  17. Photoacoustic discrimination of viable and thermally coagulated blood using a two-wavelength method for burn injury monitoring

    Science.gov (United States)

    Talbert, Robert J.; Holan, Scott H.; Viator, John A.

    2007-04-01

    Discriminating viable from thermally coagulated blood in a burn wound can be used to profile burn depth, thus aiding the removal of necrotic tissue. In this study, we used a two-wavelength photoacoustic imaging method to discriminate coagulated and non-coagulated blood in a dermal burn phantom. Differences in the optical absorption spectra of coagulated and non-coagulated blood produce different values of the ratio of peak photoacoustic amplitude at 543 and 633 nm. The absorption values obtained from spectroscopic measurements indicate that the ratio of photoacoustic pressure for 543 and 633 nm for non-coagulated blood was 15.7:1 and 1.6:1 for coagulated blood. Using planar blood layers, we found the photoacoustic ratios to be 13.5:1 and 1.6:1, respectively. Using the differences in the ratios of coagulated and non-coagulated blood, we propose a scheme using statistical classification analysis to identify the different blood samples. Based upon these distinctly different ratios, we identified the planar blood samples with an error rate of 0%. Using a burn phantom with cylindrical vessels containing coagulated and non-coagulated blood, we achieved an error rate of 11.4%. These results have shown that photoacoustic imaging could prove to be a valuable tool in the diagnosis of burns.

  18. Photoacoustic discrimination of viable and thermally coagulated blood using a two-wavelength method for burn injury monitoring

    International Nuclear Information System (INIS)

    Talbert, Robert J; Holan, Scott H; Viator, John A

    2007-01-01

    Discriminating viable from thermally coagulated blood in a burn wound can be used to profile burn depth, thus aiding the removal of necrotic tissue. In this study, we used a two-wavelength photoacoustic imaging method to discriminate coagulated and non-coagulated blood in a dermal burn phantom. Differences in the optical absorption spectra of coagulated and non-coagulated blood produce different values of the ratio of peak photoacoustic amplitude at 543 and 633 nm. The absorption values obtained from spectroscopic measurements indicate that the ratio of photoacoustic pressure for 543 and 633 nm for non-coagulated blood was 15.7:1 and 1.6:1 for coagulated blood. Using planar blood layers, we found the photoacoustic ratios to be 13.5:1 and 1.6:1, respectively. Using the differences in the ratios of coagulated and non-coagulated blood, we propose a scheme using statistical classification analysis to identify the different blood samples. Based upon these distinctly different ratios, we identified the planar blood samples with an error rate of 0%. Using a burn phantom with cylindrical vessels containing coagulated and non-coagulated blood, we achieved an error rate of 11.4%. These results have shown that photoacoustic imaging could prove to be a valuable tool in the diagnosis of burns

  19. Modified methods of stellar magnetic field measurements

    Science.gov (United States)

    Kholtygin, A. F.

    2014-12-01

    The standard methods of the magnetic field measurement, based on an analysis of the relation between the Stokes V-parameter and the first derivative of the total line profile intensity, were modified by applying a linear integral operator \\hat{L} to both sides of this relation. As the operator \\hat{L}, the operator of the wavelet transform with DOG-wavelets is used. The key advantage of the proposed method is an effective suppression of the noise contribution to the line profile and the Stokes parameter V. The efficiency of the method has been studied using model line profiles with various noise contributions. To test the proposed method, the spectropolarimetric observations of the A0 star α2 CVn, the Of?p star HD 148937, and the A0 supergiant HD 92207 were used. The longitudinal magnetic field strengths calculated by our method appeared to be in good agreement with those determined by other methods.

  20. Methods and Devices used to Measure Friction

    DEFF Research Database (Denmark)

    Jeswiet, Jack; Arentoft, Mogens; Henningsen, Poul

    2004-01-01

    . To gain a good understanding of the mechanisms at the interface and to be able to verify the friction and tribology models that exist, friction sensors are needed. Designing sensors to measure friction-stress in metal working has been pursued by many researchers. This paper surveys methods, which have...... been tried in the past and discusses some of the recent sensor designs, which can now be used to measure Friction in both production situations and for research purposes....

  1. Contact Angle Measurement in Lattice Boltzmann Method

    OpenAIRE

    Wen, Binghai; Huang, Bingfang; Qin, Zhangrong; Wang, Chunlei; Zhang, Chaoying

    2017-01-01

    Contact angle is an essential characteristic in wetting, capillarity and moving contact line; however, although contact angle phenomena are effectively simulated, an accurate and real-time measurement for contact angle has not been well studied in computational fluid dynamics, especially in dynamic environments. Here, we design a geometry-based mesoscopic scheme to onthesport measure the contact angle in the lattice Boltzmann method. The computational results without gravity effect are in exc...

  2. Statistical methods towards more efficient infiltration measurements.

    Science.gov (United States)

    Franz, T; Krebs, P

    2006-01-01

    A comprehensive knowledge about the infiltration situation in a catchment is required for operation and maintenance. Due to the high expenditures, an optimisation of necessary measurement campaigns is essential. Methods based on multivariate statistics were developed to improve the information yield of measurements by identifying appropriate gauge locations. The methods have a high degree of freedom against data needs. They were successfully tested on real and artificial data. For suitable catchments, it is estimated that the optimisation potential amounts up to 30% accuracy improvement compared to nonoptimised gauge distributions. Beside this, a correlation between independent reach parameters and dependent infiltration rates could be identified, which is not dominated by the groundwater head.

  3. Three methods to measure RH bond energies

    Energy Technology Data Exchange (ETDEWEB)

    Berkowitz, J. [Argonne National Lab., IL (United States); Ellison, G.B. [Univ. of Colorado, Boulder, CO (United States). Dept. of Chemistry and Biochemistry; Gutman, D. [Catholic Univ. of America, Washington, DC (United States). Dept. of Chemistry

    1993-03-21

    In this paper the authors compare and contrast three powerful methods for experimentally measuring bond energies in polyatomic molecules. The methods are: radical kinetics; gas phase acidity cycles; and photoionization mass spectroscopy. The knowledge of the values of bond energies are a basic piece of information to a chemist. Chemical reactions involve the making and breaking of chemical bonds. It has been shown that comparable bonds in polyatomic molecules, compared to the same bonds in radicals, can be significantly different. These bond energies can be measured in terms of bond dissociation energies.

  4. Three methods to measure RH bond energies

    International Nuclear Information System (INIS)

    Berkowitz, J.; Ellison, G.B.; Gutman, D.

    1993-01-01

    In this paper the authors compare and contrast three powerful methods for experimentally measuring bond energies in polyatomic molecules. The methods are: radical kinetics; gas phase acidity cycles; and photoionization mass spectroscopy. The knowledge of the values of bond energies are a basic piece of information to a chemist. Chemical reactions involve the making and breaking of chemical bonds. It has been shown that comparable bonds in polyatomic molecules, compared to the same bonds in radicals, can be significantly different. These bond energies can be measured in terms of bond dissociation energies

  5. A new method to measure vaginal sensibility.

    Science.gov (United States)

    Lakeman, M M E; Laan, E; Vaart, C H; Roovers, J P

    2010-06-01

    Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. To develop a new method to measure vaginal sensibility. We developed a technique to measure the sensibility of the vaginal wall consisting of a St Marks electrode on a gloved index finger, with a stimulating electrode mounted at the tip. Measurements were performed in four different target areas (caudal and cranial, posterior and anterior) by two independent female researchers in a random order. Subjects were 12 healthy women. The intra-observer reproducibility of both researchers was almost perfect (Pearsons-Rho correlation coefficient 0.77-0.96 sensibility in the cranial posterior vaginal wall relative to the cranial anterior vaginal wall, but for all measurements, researcher 2 obtained higher sensibility ratings than researcher 1. In addition, researcher 2 found a decreased sensibility in the cranial anterior vaginal wall for women not using oral contraceptives. Phase of the menstrual cycle did not influence vaginal sensibility. We developed a new instrument to measure vaginal sensibility. The instrument has excellent intra-observer reproducibility. This method is sufficiently sensitive so as to differentiate between anterior and posterior cranial vaginal wall sensibility, but outcome differs as a function of researcher. Further evaluation of the clinical use of this method is needed, provided that measurements are performed by the same researcher. (c) 2010 Wiley-Liss, Inc.

  6. EVALUATION OF THE BLOOD PRESSURE MEASURING KNOWLEDGE OF THE NURSES WHO ARE WORKING IN A MEDICAL FACULTY HOSPITAL

    Directory of Open Access Journals (Sweden)

    Tahir Kemal SAHIN

    2006-02-01

    Full Text Available Objective: The aim of this study is to determine the right knowledge of blood pressure measurement of the nurses who working in clinics. Materials and Method: 103 nurses who are working in Meram Medical Faculty Hospital were included to this descriptive study. Sampling method was stratified proportional random sampling method, with strata for the number of nurses at clinics. A questionnaire, which was formed of some questions about standard measuring methods of blood pressure, was applied to the nurses. Results: It was determined that 55.3% to 98.1% of the nurses answered the most of the questions correctly. But, they gave different answers to the questions about choosing the arm for measurement, inflation level of the cuff, deflation speed and how many measurements should be done for true result. It was found that the female nurses had much more knowledge about the tension of wrapping the cuff around the arm and the correct positioning of the stethescope than the male ones. Oppositely, the male nurses had higher correct answer rate about deflation of the cuff than the female nurses. Conclusion: It was concluded that the knowledge of blood pressure measurement of the nurses was partly insufficient. Periodical educational studies should be done for the nurses to complete the blood pressure measurement knowledge of them. [TAF Prev Med Bull 2006; 5(1.000: 8-18

  7. [Clinical signification of a modified dilution method (MDM) for blood loss assessment in the cases of nonvariceal upper gastrointestinal bleeding].

    Science.gov (United States)

    Geogiev, G; Shishenkov, M; Ninov, B; Dosheva, I

    2006-01-01

    The aim of this study was to compare the modified dilution method (MDM) for in vivo bloodless assessment with the accepted in the clinical practice methods. We measured 148 blood samples from 134 patients with nonvariceal upper gastrointestinal bleeding (NUGB) and 21 blood samples from healthy persons as a negative control. In the randomized group of 53 patients with NUGB we compared accuracy of the blood loss determination by means of erythrocyte mass loss (estimated with MDM), Allgower-Burri index and American College of Surgeon Index (ACSI). The obtained results give us a reason to recommend a combination between American College of Surgeon classification for blood loss in patients with NUGB and a parallel measurement of the MDM values.

  8. Insulin overlapping in whole blood FTIR spectroscopy in blood glucose measurements

    Science.gov (United States)

    Romo-Cárdenas, G.; Sánchez-López, J. de D.; Luque, P. A.; Cosío-León, M.; Nieto-Hipólito, Juan I.; Vázquez-Briseño, Mabel

    For the last decade, several studies on mid-IR spectroscopy for blood glucose quantification have not considered the compounds involved in the glucose regulation mechanism, in which insulin plays an important role. This work shows how insulin overlaps in the same mid-IR region in which glucose is quantified. This optical absorption interference is an important factor to be considered for this type of studies, in the scope of whole blood modeling for spectroscopy applications and the possible use of computer based metrics.

  9. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  10. Method of superconducting joint and its measurement

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Lee, Ho Jin; Hong, Gye Won

    1994-04-01

    The development of joint techniques for superconducting wires is essential to fabricate the high quality superconducting magnet. In this report, the various joining methods and their measuring techniques were reviewed. In order to fabricate a precise superconducting magnet, joining and measuring experiment by using the field decay technique carried out. The contact resistance of coupled specimens with joint was measured as 3.0 x 10 -15 ohm at 1 Tesla which is lower than that of the real operating condition of MRI magnet. It is expected that these data can be used to design and fabricate the superconducting magnets successfully. (Author) 12 refs., 20 figs., 2 tabs

  11. Measures of blood pressure and cognition in dialysis patients

    Science.gov (United States)

    There are few reports on the relationship of blood pressure with cognitive function in maintenance dialysis patients. The Cognition and Dialysis Study is an ongoing investigation of cognitive function and its risk factors in six Boston area hemodialysis units. In this analysis, we evaluated the rela...

  12. Cerebral Blood Flow Measurement Using fMRI and PET: A Cross-Validation Study

    Directory of Open Access Journals (Sweden)

    Jean J. Chen

    2008-01-01

    Full Text Available An important aspect of functional magnetic resonance imaging (fMRI is the study of brain hemodynamics, and MR arterial spin labeling (ASL perfusion imaging has gained wide acceptance as a robust and noninvasive technique. However, the cerebral blood flow (CBF measurements obtained with ASL fMRI have not been fully validated, particularly during global CBF modulations. We present a comparison of cerebral blood flow changes (ΔCBF measured using a flow-sensitive alternating inversion recovery (FAIR ASL perfusion method to those obtained using H2O15 PET, which is the current gold standard for in vivo imaging of CBF. To study regional and global CBF changes, a group of 10 healthy volunteers were imaged under identical experimental conditions during presentation of 5 levels of visual stimulation and one level of hypercapnia. The CBF changes were compared using 3 types of region-of-interest (ROI masks. FAIR measurements of CBF changes were found to be slightly lower than those measured with PET (average ΔCBF of 21.5±8.2% for FAIR versus 28.2±12.8% for PET at maximum stimulation intensity. Nonetheless, there was a strong correlation between measurements of the two modalities. Finally, a t-test comparison of the slopes of the linear fits of PET versus ASL ΔCBF for all 3 ROI types indicated no significant difference from unity (P>.05.

  13. Weighted Least-Squares Finite Element Method for Cardiac Blood Flow Simulation with Echocardiographic Data

    Directory of Open Access Journals (Sweden)

    Fei Wei

    2012-01-01

    Full Text Available As both fluid flow measurement techniques and computer simulation methods continue to improve, there is a growing need for numerical simulation approaches that can assimilate experimental data into the simulation in a flexible and mathematically consistent manner. The problem of interest here is the simulation of blood flow in the left ventricle with the assimilation of experimental data provided by ultrasound imaging of microbubbles in the blood. The weighted least-squares finite element method is used because it allows data to be assimilated in a very flexible manner so that accurate measurements are more closely matched with the numerical solution than less accurate data. This approach is applied to two different test problems: a flexible flap that is displaced by a jet of fluid and blood flow in the porcine left ventricle. By adjusting how closely the simulation matches the experimental data, one can observe potential inaccuracies in the model because the simulation without experimental data differs significantly from the simulation with the data. Additionally, the assimilation of experimental data can help the simulation capture certain small effects that are present in the experiment, but not modeled directly in the simulation.

  14. Automatic tracking and measurement of the motion of blood cells in microvessels based on analysis of multiple spatiotemporal images

    International Nuclear Information System (INIS)

    Chen, Yuan; Liu, Lei; Li, Hongjun; Zhao, Zhimin

    2011-01-01

    Automatic blood cell tracking and velocity measurement in microvessels is a crucial task in biomedical and physiological research. For the analysis of the motion of blood cells in microvessels, a commonly used method for blood cell tracking and velocity estimation is spatiotemporal image-based analysis. However, in the process of the spatiotemporal image generation, a single spatial path is used, i.e. the centreline, which is not suitable for many situations in which cells do not move strictly along the central axis of the microvessel. In this paper, we propose a new method for automatic tracking and measurement of the motion of blood cells in a microvessel based on multiple spatiotemporal images analysis. First, the proposed method adopts three spatial paths (the centreline, inner and outer contour of the microvessel) to generate three spatiotemporal images; then, the traces of blood cells in the spatiotemporal images are extracted and subsequently trace grouping and fusion processes are developed for tracking cell trajectories. For extracting traces in spatiotemporal images, a steerable filter is employed to enhance the traces in raw spatiotemporal images, and then the noise suppression function and orientation-filtering function are designed to extract trace candidates. In the subsequent grouping and fusion process, trace candidates are grouped by the proposed trace grouping rule, and then the trajectories are calculated by the proposed trace fusion approach. The results validate the proposed method for blood cell tracking and the accuracy for blood cell velocity measurement. Moreover, for the larger microvessels, we discuss the criterion of the number selection of the optimal spatial path by using both simulated and real experiments, and it can be used as the criterion for blood cell tracking in microvessels

  15. Measurement methods of building structures deflections

    Directory of Open Access Journals (Sweden)

    Wróblewska Magdalena

    2018-01-01

    Full Text Available Underground mining exploitation is leading to the occurrence of deformations manifested by, in particular, sloping terrain. The structures situated on the deforming subsoil are subject to uneven subsidence which is leading in consequence to their deflection. Before a building rectification process takes place by, e.g. uneven raising, the structure's deflection direction and value is determined so that the structure is restored to its vertical position as a result of the undertaken remedial measures. Deflection can be determined by applying classical as well as modern measurement techniques. The article presents examples of measurement methods used considering the measured elements of building structures’ constructions and field measurements. Moreover, for a given example of a mining area, the existing deflections of buildings were compared with mining terrain sloping.

  16. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  17. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors

    Directory of Open Access Journals (Sweden)

    Shouhei Koyama

    2017-01-01

    Full Text Available We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG sensor, which is a highly accurate strain sensor. This sensor is installed at the pulsation point of the human body to measure the pulse wave signal. A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement. However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure. We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject. As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased. When the measurement height was identical and only posture was changed, good accuracy was achieved. In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve. This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.

  18. Association between meal frequency with anthropometric measures and blood pressure in Iranian children and adolescents.

    Science.gov (United States)

    Ahadi, Zeinab; Kelishadi, Roya; Qorbani, Mostafa; Zahedi, Hoda; Motlagh, Mohammad E; Ardalan, Gelayol; Shafiee, Gita; Asayesh, Hamid; Larijani, Bagher; Heshmat, Ramin

    2016-07-08

    This study aimed to assess the association of meal frequency with anthropometric measures and blood pressure in Iranian children and adolescents. In this national survey, 14,880 students with 6-18 years of age were selected by stratified multistage sampling method from urban and rural regions of 30 provinces of Iran. Meal frequency was assessed by a questionnaire prepared based on global school-based student health survey .Physical measurements included height, weight, waist circumference, systolic blood pressure (SBP), and diastolic blood pressure (DBP). The participation rate was 90.6% including 49.24% girls and 75.5% urban residents. Skipping breakfast and dinner were more frequent in girls than in boys (71.6% vs. 64.1%, 91.2% vs. 86.9%, respectively, P0.05). Students who had very low intake and 1 meal per week had more risk of abdominal obesity compared with those who had 3 meals (OR 1.7, CI 95%: 1.3-2.3, and OR 1.6, CI 95%: 1.4-2.0, respectively). An inverse significant association between higher meal frequency and anthropometric indices was observed. Therefore, encouraging children and adolescents for regular meal intake should be considered as a health priority in the pediatric population.

  19. Creatinine measurement on dry blood spot sample for chronic kidney disease screening.

    Science.gov (United States)

    Silva, Alan Castro Azevedo E; Gómez, Juan Fidel Bencomo; Lugon, Jocemir Ronaldo; Graciano, Miguel Luis

    2016-03-01

    Chronic kidney disease (CKD) screening is advisable due to its high morbidity and mortality and is usually performed by sampling blood and urine. Here we present an innovative and simpler method, by measuring creatinine on a dry blood spot on filter paper. One-hundred and six individuals at high risk for CKD were enrolled. The creatinine values obtained using both tests and the demographic data of each participant allowed us to determinate the eGFR. The adopted cutoff for CKD was an eGFR value 96%, predictive negative value 55% and accuracy 92%. By the CKD-EPI equation the sensitivity was 94%, specificity 55%, predictive positive value 94%, predictive negative value 55% and accuracy 90%. A Bland and Altman analysis showed a relatively narrow range of creatinine values differences (+ 0.68mg/dl to -0.55mg/dl) inside the ± 1.96 SD, without systematic differences. Measurement of creatinine on dry blood sample is an easily feasible non-invasive diagnostic test with good accuracy that may be useful to screen chronic kidney disease.

  20. Important Considerations for Methemoglobin Measurement in Fish Blood: Assay Choice and Storage Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, Mel Anton; Rodnick, K. J.; J. A. Lacey

    2002-05-01

    Spectrophotometric assays of methaemoglobin (metHb) in rainbow trout Oncorhynchus mykiss, channel catfish Ictalurus punctatus, tilapias Tilapia niloticus and Tilapia zillii and white sturgeon Acipenser transmontanus, under baseline conditions, were low (<4%) for each species, and yet higher than human values (<1%). MetHb results for a given fish species varied significantly between assays and two assays were deemed unacceptable for particular animals. For rainbow trout, white sturgeon, and the two species of tilapia, the Dubowski method gave uncharacteristically high estimates of metHb. MetHb could not measured in tilapia blood using the Evelyn & Malloy method due to spectral interference. Only the Horecker & Brackett assay worked well for all species. Storage conditions were extremely important in the quantification of metHb in rainbow trout blood. For consistent values, samples can be stored up to 4 h on ice (0 degrees C) or at least 20 days under liquid nitrogen (-196 degrees C). Auto-oxidation, however, elevates rainbow trout metHb at -20 and -80 degrees C. It should not be assumed that the blood of fishes and humans perform similarly during assays of metHb.

  1. Dual station visualization measuring method of LRCS

    Science.gov (United States)

    Jia, Bing; Cao, Guohuaa; Lv, Qiongyinga; Zhang, Xina

    2016-10-01

    Based on the physical meaning of the laser radar scattering cross section (LRCS), When the target is the standard target or the extension target, the LRCS analytical expressions and numerical expression are deduced. Based on the LRCS expression, Proposed a dual station visualization comparison measurement method, the purpose is to use a known radar cross section of the standard target, by the power detector, and CCD images obtained gray value, calculated the target's radar cross section. In the paper, we designed the optical emission system and the optical receiving system, then detected target backscatter light power, Sampled the target image, Using MATLAB calculate the power density ratio of test objectives and reference target., compared the measured data with the empirical data, verify the feasibility of the dual station visualization comparison measurement method.

  2. Bayesian methods for measures of agreement

    CERN Document Server

    Broemeling, Lyle D

    2009-01-01

    Using WinBUGS to implement Bayesian inferences of estimation and testing hypotheses, Bayesian Methods for Measures of Agreement presents useful methods for the design and analysis of agreement studies. It focuses on agreement among the various players in the diagnostic process.The author employs a Bayesian approach to provide statistical inferences based on various models of intra- and interrater agreement. He presents many examples that illustrate the Bayesian mode of reasoning and explains elements of a Bayesian application, including prior information, experimental information, the likelihood function, posterior distribution, and predictive distribution. The appendices provide the necessary theoretical foundation to understand Bayesian methods as well as introduce the fundamentals of programming and executing the WinBUGS software.Taking a Bayesian approach to inference, this hands-on book explores numerous measures of agreement, including the Kappa coefficient, the G coefficient, and intraclass correlation...

  3. A quantitative MRI method for imaging blood-brain barrier leakage in experimental traumatic brain injury.

    Directory of Open Access Journals (Sweden)

    Wei Li

    Full Text Available Blood-brain barrier (BBB disruption is common following traumatic brain injury (TBI. Dynamic contrast enhanced (DCE MRI can longitudinally measure the transport coefficient Ktrans which reflects BBB permeability. Ktrans measurements however are not widely used in TBI research because it is generally considered to be noisy and possesses low spatial resolution. We improved spatiotemporal resolution and signal sensitivity of Ktrans MRI in rats by using a high-sensitivity surface transceiver coil. To overcome the signal drop off profile of the surface coil, a pre-scan module was used to map the flip angle (B1 field and magnetization (M0 distributions. A series of T1-weighted gradient echo images were acquired and fitted to the extended Kety model with reversible or irreversible leakage, and the best model was selected using F-statistics. We applied this method to study the rat brain one hour following controlled cortical impact (mild to moderate TBI, and observed clear depiction of the BBB damage around the impact regions, which matched that outlined by Evans Blue extravasation. Unlike the relatively uniform T2 contrast showing cerebral edema, Ktrans shows a pronounced heterogeneous spatial profile in and around the impact regions, displaying a nonlinear relationship with T2. This improved Ktrans MRI method is also compatible with the use of high-sensitivity surface coil and the high-contrast two-coil arterial spin-labeling method for cerebral blood flow measurement, enabling more comprehensive investigation of the pathophysiology in TBI.

  4. Diabetic ketoacidosis: difference between potassium determined by blood gas analysis versus plasma measurement.

    Science.gov (United States)

    Robles, Fernando César; Laguna Neto, Daniel; Dias, Fábio Guirado; Spressão, Márcia; Matos, Priscila Nascimbeni; Cordeiro, José Antônio; Pires, Antônio Carlos

    2011-06-01

    To evaluate the accuracy of potassium concentrations measured by blood gas analysis (PBG) compared with laboratory serum potassium (LSP), in the initial care of patients with diabetic ketoacidosis (DKA). Fifty three patients with diabetes mellitus were evaluated in a retrospective analysis. PBG was carried out using the Radiometer ABL 700 (Radiometer Copenhagen(®)), and results were compared with LSP ADVIA 1650 Chemistry system (Siemens(®)), the gold standard method. Both methods are based on potentiometry. Mean PBG was 3.66 mmol/L and mean LSP was 4.79 mmol/L. Mean difference between PBG and LSP was -1.13 mmol/L (p PBG measurement is faster and easier, it should not be used as a surrogate for LSP in the clinical treatment of DKA.

  5. Measurement of Uranium in Blood-Plasma of Bavarian Females

    International Nuclear Information System (INIS)

    Chaudhri, M.A.; Watling, R.J.

    2011-01-01

    It has recently been reported that the water supply in some parts of Bavaria (Germany) contains Uranium. In order to study its effects we have determined the concentrations of U in the blood plasma of 25 females. All the females came from Bavaria and were not on any medication. Blood samples were drawn from a superficial arm vein, centrifuged and plasma extracted. The plasma samples were freeze-dried and analysed in our Analytical Laboratory in Perth, Western Australia by using the technique of ICP-MS. The U contents found varied from less than 0.1 to 8.2 ppb (6.6 ng/L to 543 ng/L)

  6. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  7. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    Germans, M.R.; de Witt Hamer, P.C.; van Boven, L.J.; Zwinderman, K.A.H.; Bouma, G.J.

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  8. The Chronic and Acute Effects of Exercise Upon Selected Blood Measures.

    Science.gov (United States)

    Roitman, J. L.; Brewer, J. P.

    This study investigated the effects of chronic and acute exercise upon selected blood measures and indices. Nine male cross-country runners were studied. Red blood count, hemoglobin, and hematocrit were measured using standard laboratory techniques; mean corpuscular volume (MCV), mean corpuscular hemoglobin, and mean corpuscular hemoglobin…

  9. Accuracy of non-invasive blood pressure measurements in obese patients.

    Science.gov (United States)

    Arnold, Abigail; McNaughton, Amanda

    2018-01-11

    This article describes an evidence-based literature review, comparing upper arm and forearm blood pressure measurements using non-invasive devices on obese patients. The focus on blood pressure monitoring was in response to regularly witnessing inappropriately applied blood pressure cuffs on obese patient's upper arms in practice. An inaccurately obtained blood pressure measurement can result in the misdiagnosis and treatment of hypertension. As the prevalence of obesity grows worldwide, healthcare settings need to ensure they have the necessary equipment and trained staff to accurately measure obese patients' blood pressure. The aim of this review was to identify whether a forearm measurement provided a suitable alternative to upper arm measurements. The article discusses the development and execution of a search strategy, as well as the critical appraisal of a selected article. The results of the review demonstrated that forearm blood pressure measurements in obese patients do not replace upper arm blood pressure measurements taken with an appropriate cuff. It is recommended that further research is undertaken in order to identify suitable alternatives for obtaining an accurate non-invasive blood pressure measurement in obese patients.

  10. HDL Particle Measurement: Comparison of 5 Methods.

    Science.gov (United States)

    Matera, Robert; Horvath, Katalin V; Nair, Hari; Schaefer, Ernst J; Asztalos, Bela F

    2018-03-01

    HDL cell cholesterol efflux capacity has been documented as superior to HDL cholesterol (HDL-C) in predicting cardiovascular disease risk. HDL functions relate to its composition. Compositional assays are easier to perform and standardize than functional tests and are more practical for routine testing. Our goal was to compare measurements of HDL particles by 5 different separation methods. HDL subfractions were measured in 98 samples using vertical auto profiling (VAP), ion mobility (IM), nuclear magnetic resonance (NMR), native 2-dimensional gel electrophoresis (2D-PAGE), and pre-β1-ELISA. VAP measured cholesterol in large HDL 2 and small HDL 3 ; IM measured particle number directly in large, intermediate, and small HDL particles; NMR measured lipid signals in large, medium, and small HDL; 2D-PAGE measured apolipoprotein (apo) A-I in large (α1), medium (α2), small (α3-4), and pre-β1 HDL particles; and ELISA measured apoA-I in pre-β1-HDL. The data were normalized and compared using Passing-Bablok, Lin concordance, and Bland-Altman plot analyses. With decreasing HDL-C concentration, NMR measured a gradually lower percentage of large HDL, compared with IM, VAP, and 2D-PAGE. In the lowest HDL-C tertile, NMR measured 8% of large HDL, compared with IM, 22%; VAP, 20%; and 2D-PAGE, 18%. There was strong discordance between 2D-PAGE and NMR in measuring medium HDL ( R 2 = 0.356; r c = 0.042) and small HDL ( R 2 = 0.376; r c = 0.040). The 2D-PAGE assay measured a significantly higher apoA-I concentration in pre-β1-HDL than the pre-β1-ELISA (9.8 vs 1.6 mg/dL; R 2 = 0.246; r c = 0.130). NMR agreed poorly with the other methods in measuring large HDL, particularly in low HDL-C individuals. Similarly, there was strong discordance in pre-β1-HDL measurements between the ELISA and 2D-PAGE assays. © 2017 American Association for Clinical Chemistry.

  11. Measuring osmosis and hemolysis of red blood cells.

    Science.gov (United States)

    Goodhead, Lauren K; MacMillan, Frances M

    2017-06-01

    Since the discovery of the composition and structure of the mammalian cell membrane, biologists have had a clearer understanding of how substances enter and exit the cell's interior. The selectively permeable nature of the cell membrane allows the movement of some solutes and prevents the movement of others. This has important consequences for cell volume and the integrity of the cell and, as a result, is of utmost clinical importance, for example in the administration of isotonic intravenous infusions. The concepts of osmolarity and tonicity are often confused by students as impermeant isosmotic solutes such as NaCl are also isotonic; however, isosmotic solutes such as urea are actually hypotonic due to the permeant nature of the membrane. By placing red blood cells in solutions of differing osmolarities and tonicities, this experiment demonstrates the effects of osmosis and the resultant changes in cell volume. Using hemoglobin standard solutions, where known concentrations of hemoglobin are produced, the proportion of hemolysis and the effect of this on resultant hematocrit can be estimated. No change in cell volume occurs in isotonic NaCl, and, by placing blood cells in hypotonic NaCl, incomplete hemolysis occurs. By changing the bathing solution to either distilled water or isosmotic urea, complete hemolysis occurs due to their hypotonic effects. With the use of animal blood in this practical, students gain useful experience in handling tissue fluids and calculating dilutions and can appreciate the science behind clinical scenarios. Copyright © 2017 the American Physiological Society.

  12. Evaluation of the correlation between transcutaneous measurement andconcentration ofbilirubin inthe blood serum ofa newborn

    Directory of Open Access Journals (Sweden)

    Małgorzata Morawiecka-Pietrzak

    2016-09-01

    Full Text Available Aim: Due to the potential toxicity of high concentrations of bilirubin, newborns are monitored in terms of the potential emergence of a group at risk of the development of severe hyperbilirubinaemia and, rarely, encephalopathy and kernicterus. The transcutaneous measurement of bilirubin, as a non-invasive method, is applied in neonatal centres. The paper presents an evaluation of the correlation between the transcutaneous measurement and the concentration of bilirubin in the blood serum of a newborn, taking into consideration the reduction of the necessity to carry out blood tests related to the transcutaneous measurement. Material and method: The analysis comprised 1,076 medical histories of newborns hospitalised at the Department of Neonatology of the Municipal Hospital in Zabrze in the period from 1 January to 31 December 2013 (a primary referral centre. The inclusion criteria for the study were: performing a simultaneous transcutaneous measurement and a blood serum concentration measurement of bilirubin, gestational age ≥35 Hbd and birth weight >2,500 g. 272 children were qualified for the study. Results: Boys constituted 51.7%, and girls 48.3% of the research group. The mean gestational age was 38.7 Hbd and the mean birth weight was 3,323.4 g; 67.8% of the children were born by natural labour and 32.2% – by caesarean section. The mean Apgar score in the 5th minute was 9.8 points. The measurement of the concentration of bilirubin was performed on average on the 3.9 day of life. The mean transcutaneous measurement was 9.67 mg% (2.7–17.2 mg% and the mean concentration of bilirubin in the blood serum was 13.18 mg% (7.0–19.8 mg%; the difference was 3.5 mg% (p < 0.0001. A statistically significant positive correlation was found between the concentrations of bilirubin obtained in the transcutaneous measurement and the concentrations in the blood serum (according to Spearman, r

  13. Measurement properties of gingival biotype evaluation methods.

    Science.gov (United States)

    Alves, Patrick Henry Machado; Alves, Thereza Cristina Lira Pacheco; Pegoraro, Thiago Amadei; Costa, Yuri Martins; Bonfante, Estevam Augusto; de Almeida, Ana Lúcia Pompéia Fraga

    2018-01-19

    There are numerous methods to measure the dimensions of the gingival tissue, but few have compared the effectiveness of one method over another. This study aimed to describe a new method and to estimate the validity of gingival biotype assessment with the aid of computed tomography scanning (CTS). In each patient different methods of evaluation of the gingival thickness were used: transparency of periodontal probe, transgingival, photography, and a new method of CTS). Intrarater and interrater reliability considering the categorical classification of the gingival biotype were estimated with Cohen's kappa coefficient, intraclass correlation coefficient (ICC), and ANOVA (P validity of the CTS was determined using the transgingival method as the reference standard. Sensitivity and specificity values were computed along with theirs 95% CI. Twelve patients were subjected to assessment of their gingival thickness. The highest agreement was found between transgingival and CTS (86.1%). The comparison between the categorical classifications of CTS and the transgingival method (reference standard) showed high specificity (94.92%) and low sensitivity (53.85%) for definition of a thin biotype. The new method of CTS assessment to classify gingival tissue thickness can be considered reliable and clinically useful to diagnose thick biotype. © 2018 Wiley Periodicals, Inc.

  14. A simple trapping method to estimate abundances of blood-sucking flying insects in avian nests

    NARCIS (Netherlands)

    Tomás, G.; Merino, S.; Martínez-de la Puente, J.; Moreno, J.; Morales, J.; Lobato, E.

    2008-01-01

    [KEYWORDS: birds; biting midges; blackflies; blood parasite-insect vector-vertebrate host relationships; Ceratopogonidae; Culicoides; distance to water sources; insecticide treatment; sampling methods; Simuliidae

  15. COMPARATIVE ANALYSIS OF BLOOD GROUPING IN HEALTHY BLOOD DONOR USING GEL CARD TECHNIQUE AND TUBE METHOD

    Directory of Open Access Journals (Sweden)

    Muhammad Usman

    2016-12-01

    Full Text Available Blood grouping is a vital test in pre-transfusion testing. Both tube and gel agglutination assays are used for ABO grouping. The main object of this study was to compare ABO grouping and D typing on tube and gel agglutination assay in order to assess the efficacy of each technique. A total of 100 healthy blood donors irrespective of age and sex were included in this study. Results showed that there is no significant difference between these two techniques. However, in 10 samples it was detected that the reaction strength in serum ABO grouping by gel agglutination assay is varied by only one grade when compared to tube agglutination assay. Due to numerous positive effects of gel assay it is more beneficial to implement this technique in the setups where blood banks bear heavy routine work load.

  16. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before...... ventilation with the CO gas mixture. The amount of CO administered during each determination of CBV resulted in an increase in the CO saturation of hemoglobin of 2.1%-3.9%. A theoretical noise propagation analysis was performed by means of the Monte Carlo method. The analysis showed that a CO dose...... patients. The coefficients of variation were 6.2% and 4.7% in healthy and diseased subjects, respectively. Furthermore, the day-to-day variation of the method with respect to the total amount of circulating hemoglobin (nHb) and CBV was determined from duplicate estimates separated by 24-48 h. In conclusion...

  17. Korotkoff sound versus oscillometric cuff sphygmomanometers: comparison between auscultatory and DynaPulse blood pressure measurements.

    Science.gov (United States)

    Chio, Shiu-Shin; Urbina, Elaine M; Lapointe, Jeffery; Tsai, Jeffrey; Berenson, Gerald S

    2011-01-01

    Listening to Korotkoff sounds (K-sounds) to determine systolic and diastolic blood pressure (BP) has been the standard for noninvasive BP measurement in medical practices for nearly 100 years. It is the essential tool used for evaluation and assessment of patients with hypertension and risks of cardiovascular diseases (CVD) by physicians and nurses despite limited understanding of the nature of K-sounds. Analyzing cuff oscillometric signals to obtain BP has been the foundation of most digital BP monitors available today. DynaPulse is an oscillometric digital BP monitor that records and analyzes subtle changes of pulse waveforms during the course of a BP measurement while cuff pressure slowly decreases from above systolic to below diastolic. This study compares systolic and diastolic readings obtained by K-sound method following the Bogalusa Heart Study protocol and BP measured by DynaPulse (DP2000A) monitor, in order to better understand the nature and difference between K-sound and oscillometric methods. Analysis of means and differences is applied to BP data collected from 803 subjects examined in the Bogalusa Heart Study. The results indicated: 1) DynaPulse systolic was 9 mm Hg higher (P sound auscultatory measurement. Understanding the methods and differences of DynaPulse oscillometric and K-sound BP measurements is important for clinic BP screening and self-BP monitoring, as well as future research to improve hypertension and CVD managements. Copyright © 2011 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  18. Automated back titration method to measure phosphate

    International Nuclear Information System (INIS)

    Comer, J.; Tehrani, M.; Avdeef, A.; Ross, J. Jr.

    1987-01-01

    Phosphate was measured in soda drinks and as an additive in flour, by a back titration method in which phosphate was precipitated with lanthanum, and the excess lanthanum was titrated with fluoride. All measurements were performed using the Orion fluoride electrode and the Orion 960 Autochemistry System. In most commercial automatic titrators, the inflection point of the titration curve, calculated from the first derivative of the curve, is used to find the equivalence polar of the titration. The inflection technique is compared with a technique based on Gran functions, which uses data collected after the end point and predicts the equivalence point accordingly

  19. Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation

    Directory of Open Access Journals (Sweden)

    Fen Chen

    2018-03-01

    Full Text Available Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD, acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO method and twelve-layer concentric objects (TLCO method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia.

  20. Comparison of microstickies measurement methods. Part I, sample preparation and measurement methods

    Science.gov (United States)

    Mahendra R. Doshi; Angeles Blanco; Carlos Negro; Gilles M. Dorris; Carlos C. Castro; Axel Hamann; R. Daniel Haynes; Carl Houtman; Karen Scallon; Hans-Joachim Putz; Hans Johansson; R.A. Venditti; K. Copeland; H.-M. Chang

    2003-01-01

    Recently, we completed a project on the comparison of macrostickies measurement methods. Based on the success of the project, we decided to embark on this new project on comparison of microstickies measurement methods. When we started this project, there were some concerns and doubts principally due to the lack of an accepted definition of microstickies. However, we...

  1. Discarding the first of three nurse-auscultatory or oscillometric blood pressure measurements does not improve the association of office blood pressure with ABPM.

    Science.gov (United States)

    Graves, John W; Grossardt, Brandon R

    2010-06-01

    Guidelines for office blood pressure (BP) measurements recommend two or more readings at each visit. It has been suggested that discarding the first reading may improve the diagnostic utility of office readings. We compare two methods of office BP measurement to determine whether discarding the first BP affects their association with ambulatory blood pressure monitoring (ABPM) readings. We studied measurements in 313 mildly hypertensive patients (181 men, median age 51 years) at the end of the washout phase of a hypertension treatment trial. All patients had three auscultatory readings by a trained nurse using a mercury manometer before a 24-h ABPM and three automated readings (Omron 705 CP) to American Heart Association standards after ABPM. Daytime ABPM (09:00-21:00) of systolic BP and diastolic BP were compared with office methods using first only, second and third only, and all three readings. Associations were assessed using Bland-Altman plots and Pearson's correlations. Bland-Altman plots revealed no differences between office methods and daytime ABPM regardless of whether the first reading was included or discarded. Results were similar for both systolic BP and diastolic BP. The Pearson correlations of office method readings with ABPM readings were lowest using the first measurement alone; however, discarding the first measurement did not improve the correlation compared with using all three readings. Discarding the first office BP reading does not change the association of office BP with ABPM or improve the correlation with ABPM values in hypertensive patients.

  2. A simple method for repetitive blood sampling of cattle

    African Journals Online (AJOL)

    A simple practical technique is described for the collection of blood samples from at least six catile concurrenily at short time interuals for up to 48 h. The technique is advantageous in that it is carried out under minimum srress conditions. 'n Eenvoudige praktiese tegniek vir die gelyktydige trekking van bloedmonsters van ten ...

  3. Microfluidic method for measuring viscosity using images from smartphone

    Science.gov (United States)

    Kim, Sooyeong; Kim, Kyung Chun; Yeom, Eunseop

    2018-05-01

    The viscosity of a fluid is the most important characteristic in fluid rheology. Many microfluidic devices have been proposed for easily measuring the fluid viscosity of small samples. A hybrid system consisting of a smartphone and microfluidic device can offer a mobile laboratory for performing a wide range of detection and analysis functions related to healthcare. In this study, a new mobile sensing method based on a microfluidic device was proposed for fluid viscosity measurements. By separately delivering sample and reference fluids into the two inlets of a Y-shaped microfluidic device, an interfacial line is induced at downstream of the device. Because the interfacial width (W) between the sample and reference fluid flows was determined by their pressure ratio, the viscosity (μ) of the sample could be estimated by measuring the interfacial width. To distinguish the interfacial width of a sample, optical images of the flows at downstream of the Y-shaped microfluidic device were acquired using a smartphone. To check the measurement accuracy of the proposed method, the viscosities of glycerol mixtures were compared with those measured by a conventional viscometer. The proposed technique was applied to monitor the variations in blood and oil samples depending on storage or rancidity. We expect that this mobile sensing method based on a microfluidic device could be utilized as a viscometer with significant advantages in terms of mobility, ease-of-operation, and data management.

  4. Reproducibility of wrist home blood pressure measurement with position sensor and automatic data storage

    Directory of Open Access Journals (Sweden)

    Nickenig Georg

    2009-05-01

    Full Text Available Abstract Background Wrist blood pressure (BP devices have physiological limits with regards to accuracy, therefore they were not preferred for home BP monitoring. However some wrist devices have been successfully validated using etablished validation protocols. Therefore this study assessed the reproducibility of wrist home BP measurement with position sensor and automatic data storage. Methods To compare the reproducibility of three different(BP measurement methods: 1 office BP, 2 home BP (Omron wrist device HEM- 637 IT with position sensor, 3 24-hour ambulatory BP(24-h ABPM (ABPM-04, Meditech, Hunconventional sphygmomanometric office BP was measured on study days 1 and 7, 24-h ABPM on study days 7 and 14 and home BP between study days 1 and 7 and between study days 8 and 14 in 69 hypertensive and 28 normotensive subjects. The correlation coeffcient of each BP measurement method with echocardiographic left ventricular mass index was analyzed. The schedule of home readings was performed according to recently published European Society of Hypertension (ESH- guidelines. Results The reproducibility of home BP measurement analyzed by the standard deviation as well as the squared differeces of mean individual differences between the respective BP measurements was significantly higher than the reproducibility of office BP (p Conclusion The short-term reproducibility of home BP measurement with the Omron HEM-637 IT wrist device was superior to the reproducibility of office BP and 24- h ABPM measurement. Furthermore, home BP with the wrist device showed similar correlations to targed organ damage as recently reported for upper arm devices. Although wrist devices have to be used cautious and with defined limitations, the use of validated devices with position sensor according to recently recommended measurement schedules might have the potential to be used for therapy monitoring.

  5. assessment of measures of adiposity that correlate with blood ...

    African Journals Online (AJOL)

    independent risk factors for cardiovascular morbidity and mortality.4,5. ASSESSMENT OF MEASURES OF ... body fat, the variance for adiposity measurement is very small suggesting reliability of BMI as measure of ..... fat distribution reduction through lifestyle modification, including exercise and diet, may have significant ...

  6. Method for traceable measurement of LTE signals

    Science.gov (United States)

    Sunder Dash, Soumya; Pythoud, Frederic; Leuchtmann, Pascal; Leuthold, Juerg

    2018-04-01

    This contribution presents a reference setup to measure the power of the cell-specific resource elements present in downlink long term evolution (LTE) signals in a way that the measurements are traceable to the international system of units. This setup can be used to calibrate the LTE code-selective field probes that are used to measure the radiation of base stations for mobile telephony. It can also be used to calibrate LTE signal generators and receivers. The method is based on traceable scope measurements performed directly at the output of a measuring antenna. It implements offline digital signal processing demodulation algorithms that consider the digital down-conversion, timing synchronization, frequency synchronization, phase synchronization and robust LTE cell identification to produce the downlink time-frequency LTE grid. Experimental results on conducted test scenarios, both single-input-single-output and multiple-input-multiple-output antenna configuration, show promising results confirming measurement uncertainties of the order of 0.05 dB with a coverage factor of 2.

  7. Validation of curve-fitting method for blood retention of {sup 99m}Tc-GSA. Comparison with blood sampling method

    Energy Technology Data Exchange (ETDEWEB)

    Ha-Kawa, Sang Kil; Suga, Yutaka; Kouda, Katsuyasu; Ikeda, Koshi; Tanaka, Yoshimasa [Kansai Medical Univ., Moriguchi, Osaka (Japan)

    1997-02-01

    We investigated a curve-fitting method for the rate of blood retention of {sup 99m}Tc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent {sup 99m}Tc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of {sup 99m}Tc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1{+-}2.1% (mean{+-}standard deviation, n=77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5{+-}6.1%, n=135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2{+-}11.6%, n=13; vs. 31.9{+-}2.8%, n=7, p<0.0001). There was a highly linear correlation between the %IDs of {sup 99m}Tc-GSA and the plasma retention rate for indocyanine green (r=-0.869, p<0.0001, n=27). These results indicate that the curve-fitting method provides an accurate %ID of {sup 99m}Tc-GSA and could be a substitute for the blood sampling method. (author)

  8. [Evaluating the applicability of medical examinations constituting "the protocol of obtaining a blood sample" in measuring the degree of intoxication].

    Science.gov (United States)

    Engelgardt, Piotr; Grzech, Weronika; Drzewiecki, Jarosław; Sliwka, Karol

    2010-01-01

    Breathalysing and blood analysis is the basic instrument of measuring the level of intoxication. Prior to collecting a blood sample, an individual suspected of being under the influence of alcohol is examined by a physician, who fills out the "protocol of obtaining a blood sample". This work aims at evaluating the applicability of the described examination in measuring the level of intoxication. In order to do so, our team analyzed 352 "protocols of obtaining blood sample" referred to the Forensic Laboratory KWP in Bydgoszcz, Poland, and compared them with the results of blood analysis. The results of the above analysis point to the fact that the elements of medical examination constituting "the protocol of obtaining a blood sample" are of a minor usefulness in determining the degree of intoxication with ethyl alcohol. The smell from the mouth and the conclusions formulated the examining physician prove to be the most useful. The summary usage of deviations from the norm does not seem to increase the usefulness of methods used within "the protocol of obtaining a blood sample" in evaluating the degree of intoxication.

  9. A Rapid and Low-Cost Nonlithographic Method to Fabricate Biomedical Microdevices for Blood Flow Analysis

    Directory of Open Access Journals (Sweden)

    Elmano Pinto

    2014-12-01

    Full Text Available Microfluidic devices are electrical/mechanical systems that offer the ability to work with minimal sample volumes, short reactions times, and have the possibility to perform massive parallel operations. An important application of microfluidics is blood rheology in microdevices, which has played a key role in recent developments of lab-on-chip devices for blood sampling and analysis. The most popular and traditional method to fabricate these types of devices is the polydimethylsiloxane (PDMS soft lithography technique, which requires molds, usually produced by photolithography. Although the research results are extremely encouraging, the high costs and time involved in the production of molds by photolithography is currently slowing down the development cycle of these types of devices. Here we present a simple, rapid, and low-cost nonlithographic technique to create microfluidic systems for biomedical applications. The results demonstrate the ability of the proposed method to perform cell free layer (CFL measurements and the formation of microbubbles in continuous blood flow.

  10. Development of dual micro-PIV system for simultaneous velocity measurements: optical arrangement techniques and application to blood flow measurements

    International Nuclear Information System (INIS)

    Kvon, Alexandr; Lee, Yeon Ho; Cheema, Taqi Ahmad; Park, Cheol Woo

    2014-01-01

    Blood rheological characteristics can significantly vary with the motion of red blood cells (RBCs) in plasma. Moreover, RBCs show a complicated behavior in micro vessels. Thus, the determination of either plasma or blood cell velocity distribution has been the primary objective in blood flow analysis. However, the conditions during blood flow analyses are different from the actual physiological conditions, wherein the motion of the two distinct blood phases simultaneously occurs. In this study, we used an in vitro micro-particle image velocimetry, which is a reliable velocity field measurement technique, to evaluate the velocity distribution of plasma and blood cells simultaneously. Blood flow through a rectangular microchannel was determined using special optical filter arrangements and by assuming two different hematocrit values. Using the proposed technique, the averaged parabolic velocity profiles for the RBCs and plasma were successfully obtained and compared. The developed simultaneous measurement technique can be used to predict blood cell and plasma behaviors simultaneously with high accuracy under given clinical conditions. (paper)

  11. Association between different measurements of blood pressure variability by ABP monitoring and ankle-brachial index

    Directory of Open Access Journals (Sweden)

    Moreira Leila B

    2010-11-01

    Full Text Available Abstract Background Blood pressure (BP variability has been associated with cardiovascular outcomes, but there is no consensus about the more effective method to measure it by ambulatory blood pressure monitoring (ABPM. We evaluated the association between three different methods to estimate BP variability by ABPM and the ankle brachial index (ABI. Methods and Results In a cross-sectional study of patients with hypertension, BP variability was estimated by the time rate index (the first derivative of SBP over time, standard deviation (SD of 24-hour SBP; and coefficient of variability of 24-hour SBP. ABI was measured with a doppler probe. The sample included 425 patients with a mean age of 57 ± 12 years, being 69.2% women, 26.1% current smokers and 22.1% diabetics. Abnormal ABI (≤ 0.90 or ≥ 1.40 was present in 58 patients. The time rate index was 0.516 ± 0.146 mmHg/min in patients with abnormal ABI versus 0.476 ± 0.124 mmHg/min in patients with normal ABI (P = 0.007. In a logistic regression model the time rate index was associated with ABI, regardless of age (OR = 6.9, 95% CI = 1.1- 42.1; P = 0.04. In a multiple linear regression model, adjusting for age, SBP and diabetes, the time rate index was strongly associated with ABI (P Conclusion Time rate index is a sensible method to measure BP variability by ABPM. Its performance for risk stratification of patients with hypertension should be explored in longitudinal studies.

  12. A simple assay method for added stable caesium in blood plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kaikkonen, M. [Dept. of Basic Veterinary Sciences, Univ. of Helsinki (Finland); Lehto, J. [Lab. of Radiochemistry, Univ. of Helsinki (Finland)

    2006-07-01

    A new assay method was developed to determine added stable caesium (Cs) in blood plasma. The simple and inexpensive method is based on the competition between stable and radioactive Cs in binding to ammonium-iron(II)-hexacyanoferrate(III) (AFCF), followed by the precipitation of AFCF-bound Cs with plasma proteins, and the measurement of the radioactivity of the precipitate. For data treatment, standard procedures of radioimmunoassay were used. At present stage, the qualitative detection limit is around 0.2 {mu}mol L{sup -1}, and the practical limit for quantitative results around 1 {mu}mol L{sup -1}. The method is applicable only for recently added Cs in blood plasma, and cannot be used to measure endogenous plasma Cs or Cs in other tissues. Determining plasma kinetics of Cs might be useful in the study of some aspects of potassium kinetics, since these two alkali metals are transported into cells by the same cellular mechanism (Na,K-ATPase). (orig.)

  13. New Methods of Magnetic Field Measurements

    Science.gov (United States)

    Kholtygin, A. F.

    2015-04-01

    The standard methods of magnetic field measurements, based on the relation between the Stokes V parameter and the first derivative of the line profile intensity were modified by applying a linear integral transform to both sides of this relation. We used the wavelet integral transform with the DOG wavelets. The key advantage of the proposed method is the effective suppression of the noise contribution both to the line profile and the Stokes V parameter. To test the proposed method, spectropolarimetric observations of the young O star θ1 Ori C were used. We also demonstrate that the smoothed Time Variation Spectra (smTVS) can be used as a tool for detecting the local stellar magnetic fields.

  14. [Physical activity level and home blood pressure measurement: Pilot study "Acti-HTA"].

    Science.gov (United States)

    Sosner, P; Ott, J; Steichen, O; Bally, S; Krummel, T; Brucker, M; Lequeux, B; Dourmap, C; Llaty, P; Le Coz, S; Baguet, S; Miranne, A; Labrunée, M; Gremeaux, V; Lopez-Sublet, M

    2015-06-01

    While physical activity (PA) is recommended for high blood pressure management, the level of PA practice of hypertensive patients remains unclear. We aimed to assess the association between the level of both PA and blood pressure of individuals consulting in 9 hypertension specialist centres. Eighty-five hypertensive patients were included (59 ± 14 years, 61% men, 12% smokers, 29% with diabetes). Following their consultation, they performed home blood pressure measurement (HBPM) over 7 days (2 in the morning+2 in the evening), they wrote in a dedicated form their daily activities to estimate the additional caloric expenditure using Acti-MET device (built from International physical Activity Questionnaire [IPAQ]). Thus, patients completed a self-administered questionnaire "score of Dijon" (distinguishing active subjects with a score>20/30, from sedentaryactive" subjects (48.9% vs. 34.2%, P=0.1773). In conclusion, our results demonstrate a "tendency" to a higher level of reported PA for subjects whose hypertension was controlled. This encourages us to continue with a study that would include more subjects, which would assess PA level using an objective method such as wearing an accelerometer sensor. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. The number of visits and blood pressure measurements influence the prevalence of high blood pressure in adolescents.

    Science.gov (United States)

    de Oliveira, Luciano Machado Ferreira Tenório; da Silva, Alison Oliveira; Diniz, Paula Rejane Beserra; Farah, Breno Quintella; Pirauá, André Luiz Torres; de Lima Neto, Antônio José; Feitosa, Wallacy Milton do Nascimento; Tassitano, Rafael Miranda; Ritti-Dias, Raphael M

    2017-06-01

    The aim of this study was to analyze the influence of the number of visits and the number of blood pressure (BP) measurements on the prevalence of high blood pressure (HBP) in adolescents. A cross-sectional epidemiologic study with 481 adolescents (14-19 years old) selected using a random cluster sampling strategy. We measured the BP three times in a first visit. Adolescents with HBP performed subsequent visits. The final calculation of BP followed four strategies: the 1st measure, mean of 1st and 2nd measurements, mean of all three measurements, and averaging the 2nd and 3rd measurements. The prevalence of HBP in the first and second visits was 6.4% and 1.9%, and the prevalence of hypertension (after three visits) was 1.7%. The prevalence of HBP varied from 8.6%-18.6% for boys and 4.6%-9.2% for girls, using the average 2nd and 3rd measurements and the 1st measurement, respectively. In all strategies, HBP and hypertension were more prevalent in boys and students attending the nocturnal shift. The number of visits and number of measurements affect the prevalence of HBP and hypertension in adolescents. Thus, clinicians and researchers should consider these aspects when assessing BP in adolescents aged 14-19 years old. Copyright © 2017 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.

  16. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids

    Science.gov (United States)

    Aarnes, Turi K.; Hubbell, John A.E.; Lerche, Phillip; Bednarski, Richard M.

    2012-01-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was −9.9 ± 21.9 mmHg with a range of −76 to 54 mmHg, and the 95% limits of agreement (LOA) were −33 to 53 mmHg. The difference between DABP measurements was −1.8 ± 15.6 mmHg with a range of −81 to 36 mmHg, and the 95% LOA were −32 to 29 mmHg. The difference between MABP measurements was −2.9 ± 17.0 mmHg with a range of −81 to 36 mmHg, and the 95% LOA were −30 to 36 mmHg. Accurate ABP monitoring in anesthetized camelids cannot be accomplished using the oscillometric method. PMID:23372197

  17. Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids.

    Science.gov (United States)

    Aarnes, Turi K; Hubbell, John A E; Lerche, Phillip; Bednarski, Richard M

    2012-08-01

    This study assessed the accuracy of the oscillometric method for arterial blood pressure (ABP) monitoring in anesthetized camelids. Twenty camelids were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured directly and using the oscillometric method. The mean difference between SABP measurements was -9.9 ± 21.9 mmHg with a range of -76 to 54 mmHg, and the 95% limits of agreement (LOA) were -33 to 53 mmHg. The difference between DABP measurements was -1.8 ± 15.6 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -32 to 29 mmHg. The difference between MABP measurements was -2.9 ± 17.0 mmHg with a range of -81 to 36 mmHg, and the 95% LOA were -30 to 36 mmHg. Accurate ABP monitoring in anesthetized camelids cannot be accomplished using the oscillometric method.

  18. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    Energy Technology Data Exchange (ETDEWEB)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S. (Departments of Anaesthesiology, Obstetrics and Gynaecology and Medical Physics, Karolinska Institute at Huddinge University Hospital, Stockholm (Sweden))

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author).

  19. A microfluidic device for simultaneous measurement of viscosity and flow rate of blood in a complex fluidic network.

    Science.gov (United States)

    Jun Kang, Yang; Yeom, Eunseop; Lee, Sang-Joon

    2013-01-01

    Blood viscosity has been considered as one of important biophysical parameters for effectively monitoring variations in physiological and pathological conditions of circulatory disorders. Standard previous methods make it difficult to evaluate variations of blood viscosity under cardiopulmonary bypass procedures or hemodialysis. In this study, we proposed a unique microfluidic device for simultaneously measuring viscosity and flow rate of whole blood circulating in a complex fluidic network including a rat, a reservoir, a pinch valve, and a peristaltic pump. To demonstrate the proposed method, a twin-shaped microfluidic device, which is composed of two half-circular chambers, two side channels with multiple indicating channels, and one bridge channel, was carefully designed. Based on the microfluidic device, three sequential flow controls were applied to identify viscosity and flow rate of blood, with label-free and sensorless detection. The half-circular chamber was employed to achieve mechanical membrane compliance for flow stabilization in the microfluidic device. To quantify the effect of flow stabilization on flow fluctuations, a formula of pulsation index (PI) was analytically derived using a discrete fluidic circuit model. Using the PI formula, the time constant contributed by the half-circular chamber is estimated to be 8 s. Furthermore, flow fluctuations resulting from the peristaltic pumps are completely removed, especially under periodic flow conditions within short periods (T flow rate conditions [(a) known blood flow rate via a syringe pump, (b) unknown blood flow rate via a peristaltic pump]. As a result, the flow rate and viscosity of blood can be simultaneously measured with satisfactory accuracy. In addition, the proposed method was successfully applied to identify the viscosity of rat blood, which circulates in a complex fluidic network. These observations confirm that the proposed method can be used for simultaneous measurement of viscosity

  20. Reproduction of pressure field in ultrasonic-measurement-integrated simulation of blood flow.

    Science.gov (United States)

    Funamoto, Kenichi; Hayase, Toshiyuki

    2013-07-01

    Ultrasonic-measurement-integrated (UMI) simulation of blood flow is used to analyze the velocity and pressure fields by applying feedback signals of artificial body forces based on differences of Doppler velocities between ultrasonic measurement and numerical simulation. Previous studies have revealed that UMI simulation accurately reproduces the velocity field of a target blood flow, but that the reproducibility of the pressure field is not necessarily satisfactory. In the present study, the reproduction of the pressure field by UMI simulation was investigated. The effect of feedback on the pressure field was first examined by theoretical analysis, and a pressure compensation method was devised. When the divergence of the feedback force vector was not zero, it influenced the pressure field in the UMI simulation while improving the computational accuracy of the velocity field. Hence, the correct pressure was estimated by adding pressure compensation to remove the deteriorating effect of the feedback. A numerical experiment was conducted dealing with the reproduction of a synthetic three-dimensional steady flow in a thoracic aneurysm to validate results of the theoretical analysis and the proposed pressure compensation method. The ability of the UMI simulation to reproduce the pressure field deteriorated with a large feedback gain. However, by properly compensating the effects of the feedback signals on the pressure, the error in the pressure field was reduced, exhibiting improvement of the computational accuracy. It is thus concluded that the UMI simulation with pressure compensation allows for the reproduction of both velocity and pressure fields of blood flow. Copyright © 2012 John Wiley & Sons, Ltd.

  1. Hematocrit Interference of Blood Glucose Meters for Patient Self-Measurement

    Science.gov (United States)

    Ramljak, Sanja; Lock, John Paul; Schipper, Christina; Musholt, Petra B.; Forst, Thomas; Lyon, Martha; Pfützner, Andreas

    2013-01-01

    Background Abnormal hematocrit levels may interfere with glucose readings of patient self-assessment blood glucose (BG) meters. The aim of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of BG meters applying different measurement technologies. Methods Venous heparinized blood was manipulated to contain three different BG concentrations (50–90, 120–180, and 280–350 mg/dl) and five different hematocrit levels (25%, 35%, 45%, 55%, and 65%). After careful oxygenation to normal blood oxygen pressure (65–100 mmHg), each sample was measured (eight times) with the following devices: Accu-Chek® Aviva, Nano, and Active, Breeze®2 and Contour®, FreeStyle Freedom Lite®, GlucoDr. auto™, Glucofix® mio Plus, GlucoLab™, GlucoMen® LX Plus, Nova Max® Link, Nova Max® Plus, OneTouch® Ultra®2 and Verio®,On Call® Plus and Platinum, Optium Xceed®, Precision Xceed®, and TaiDoc Fora TD-4227. A YSI 2300 STAT Plus™ glucose analyzer served as reference method. Stability to hematocrit influence was assumed, with hematocrit levels. Results Six of the investigated meters showed a stable performance in this investigation: Accu-Chek Active (7%), Glucofix mio Plus (5%), GlucoMen LX Plus (4%), NovaMax Plus (4%), Nova Max Link (7%), and OneTouch Verio (3%). All other meters failed this hematocrit interference test, with FreeStyle Freedom Lite (11%), and On Call Platinum (12%) being the better devices and On Call Plus (68%), GlucoLab (51%), TaiDoc Fora TD-4227 (39%), and Breeze 2 (38%) showing the worst performance. Conclusions Hematocrit may affect BG meter performance in daily routine. In case of interference, low hematocrit values (hematocrit interference. PMID:23439176

  2. Evaluation of a method to measure long term cortisol levels.

    Science.gov (United States)

    Manenschijn, Laura; Koper, Jan W; Lamberts, Steven W J; van Rossum, Elisabeth F C

    2011-01-01

    Elevated levels of cortisol are known to induce various symptoms and diseases, e.g. abdominal obesity, type 2 diabetes, osteoporosis and cardiovascular disease. Measuring serum, saliva and urine cortisol is limited to one time point. Measurement of cortisol in scalp hair is a recently developed method to measure long term cortisol levels. The aim of this study was to investigate whether hair cortisol is a feasible parameter to measure cortisol exposure. We collected hair samples of 195 healthy individuals, 9 hypercortisolemic and one hypocortisolemic patient and measured hair cortisol levels. Cortisol was extracted from scalp hair using methanol and cortisol levels were measured using a salivary ELISA kit. Measurement of waist and hip circumferences and blood pressure was performed in 46 healthy subjects. We found a positive correlation between hair cortisol and both waist circumference (r=0.392, p=0.007) and waist-to-hip ratio (WHR) (r=0.425, p=0.003). No correlations were found between hair cortisol levels and BMI, blood pressure or age. There was no decline in cortisol levels in six consecutive hair segments. Hair cortisol levels were elevated in patients with known hypercortisolism (pcortisol was positively correlated with WHR, suggesting that hair cortisol reflects cortisol exposure at tissue level, which was also supported by elevated hair cortisol levels in hypercortisolemic patients and concordance between hair cortisol levels and clinical disease course. Cortisol levels in hair are slightly influenced by hair treatment but not by natural hair colour, use of hair products, gender or age. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. SPECT measurements of cerebral blood volume before and after acetazolamide in occlusive cerebrovascular diseases

    International Nuclear Information System (INIS)

    Inoue, Yusuke; Momose, Toshimitsu; Machida, Kikuo; Honda, Norinari; Nishikawa, Junichi; Sasaki, Yasuhito.

    1994-01-01

    Cerebral blood volume before and after acetazolamide was measured by SPECT to evaluate cerebral vasodilatory capacity in eight patients with cerebrovascular disease and five control subjects. Two SPECT measurements were performed serially, and acetazolamide was administered between them. The ratio of increase in hemispheric blood volume was calculated, and it was compared with the results of cerebral blood flow and cerebral blood volume measurements. A cerebral vasodilatory capacity map, the image after acetazolamide minus the baseline image, was also produced. Acetazolamide increased hemispheric blood volume in all subjects. The ratio of increase was lower in the involved hemispheres of the patients with unilateral carotid disease than in the uninvolved hemispheres of the patients and control subjects. The ratio of concordance with blood flow and blood volume measurements was approximated at 80%. Cerebral vasodilatory capacity mapping revealed three defects compatible with the clinical data. SPECT measurements of cerebral blood volume after acetazolamide can be performed following baseline SPECT with no additional radiotracer, and may be helpful to assess hemodynamic status. (author)

  4. Large subcriticality measurement by pulsed neutron method

    International Nuclear Information System (INIS)

    Yamane, Y.; Yoshida, A.; Nishina, K.; Kobayashi, K.; Kanda, K.

    1985-01-01

    To establish the method determining large subcriticalities in the field of nuclear criticality safety, the authors performed pulsed neutron experiments using the Kyoto University Critical Assembly (KUCA) at Research Reactor Institute, Kyoto University and the Cockcroft-Walton type accelerator attached to the assembly. The area-ratio method proposed by Sjoestrand was employed to evaluate subcriticalities from neutron decay curves measured. This method has the shortcomings that the neutron component due to a decay of delayed neutrons remarkably decreases as the subcriticality of an objective increases. To overcome the shortcoming, the authors increased the frequency of pulsed neutron generation. The integral-version of the area-ratio method proposed by Kosaly and Fisher was employed in addition in order to remove a contamination of spatial higher modes from the decay curve. The latter becomes significant as subcriticality increases. The largest subcriticality determined in the present experiments was 125.4 dollars, which was equal to 0.5111 in a multiplication factor. The calculational values evaluated by the computer code KENO-IV with 137 energy groups based on the Monte Carlo method agreed well with those experimental values

  5. An Automated Method to Quantify Radiation Damage in Human Blood Cells

    Energy Technology Data Exchange (ETDEWEB)

    Gordon K. Livingston, Mark S. Jenkins and Akio A. Awa

    2006-07-10

    Cytogenetic analysis of blood lymphocytes is a well established method to assess the absorbed dose in persons exposed to ionizing radiation. Because mature lymphocytes circulate throughout the body, the dose to these cells is believed to represent the average whole body exposure. Cytogenetic methods measure the incidence of structural aberrations in chromosomes as a means to quantify DNA damage which occurs when ionizing radiation interacts with human tissue. Methods to quantify DNA damage at the chromosomal level vary in complexity and tend to be laborious and time consuming. In a mass casualty scenario involving radiological/nuclear materials, the ability to rapidly triage individuals according to radiation dose is critically important. For high-throughput screening for dicentric chromosomes, many of the data collection steps can be optimized with motorized microscopes coupled to automated slide scanning platforms.

  6. Optical measurement of blood flow in exercising skeletal muscle: a pilot study

    Science.gov (United States)

    Wang, Detian; Baker, Wesley B.; Parthasarathy, Ashwin B.; Zhu, Liguo; Li, Zeren; Yodh, Arjun G.

    2017-07-01

    Blood flow monitoring during rhythm exercising is very important for sports medicine and muscle dieases. Diffuse correlation spectroscopy(DCS) is a relative new invasive way to monitor blood flow but suffering from muscle fiber motion. In this study we focus on how to remove exercise driven artifacts and obtain accurate estimates of the increase in blood flow from exercise. Using a novel fast software correlator, we measured blood flow in forearm flexor muscles of N=2 healthy adults during handgrip exercise, at a sampling rate of 20 Hz. Combining the blood flow and acceleration data, we resolved the motion artifact in the DCS signal induced by muscle fiber motion, and isolated the blood flow component of the signal from the motion artifact. The results show that muscle fiber motion strongly affects the DCS signal, and if not accounted for, will result in an overestimate of blood flow more than 1000%. Our measurements indicate rapid dilation of arterioles following exercise onset, which enabled blood flow to increase to a plateau of 200% in 10s. The blood flow also rapidly recovered to baseline following exercise in 10s. Finally, preliminary results on the dependence of blood flow from exercise intensity changes will be discussed.

  7. Measurement of Finger Blood Flow in Raynauds Phenomenon by Radionuclide Angiography

    International Nuclear Information System (INIS)

    Lim, Sang Moo; Chung, June Key; Lee, Myung Chul; Kim, Sang Joon; Choi, Sung Jae; Koh, Chang Soon

    1987-01-01

    In Raynauds phenomenon, the authors measured finger blood flow after ice water exposure by analyzing the time activity curve of radionuclide angiography on both hands. The results were as follows: 1) The digital blood flow did not decrease after ice water exposure in normal subjects. 2) In the patients with Raynauds phenomenon, there were two groups: the one had decreased digital blood flow after cold exposure, and the other had paradoxically increased digital blood flow after cold exposure. 3) There was no difference in the digital blood flow of hand in room temperature between the normal and the patients with reduced digital blood flow after cold exposure, but the digital blood flow of the hand in room temperature was markedly reduced in the patients with paradoxically increased flow after cold exposure. 4) In the static image the difference was not significant in comparison with the dynamic study, because it represents pooling of the blood in the vein rather than flow. 5) After the treatment with nifedipine, the digital blood flow increased. In conclusion, the radionuclide angiography was useful in measuring the digital blood flow in Raynauds phenomenon, and further studies with various drugs is expected.

  8. Stable xenon CT measurement of cerebral blood flow in cardiac transplantation candidates: Correlation with cognitive function

    International Nuclear Information System (INIS)

    Bello, J.A.; Fink, M.E.; Hilal, S.K.; Rose, E.A.; Reemtsma, K.

    1987-01-01

    Thirteen consecutive unselected patients with NYHA class 4 cardiac failure referred for cardiac transplantation underwent neurologic examination and cerebral blood flow measurement (rCBF) using the stable xenon enhanced CT method on a GE9800 system. Eleven men and two women were studied (mean age = 43.8 +- 6.1). On neurological examination, six of the patients demonstrated normal mental function; the remaining seven patients demonstrated memory, language, or learning impairment. There was no difference in mean cardiac output between the groups (4.9 L/min +- 1.68 vs. 4.2L/min +- 1.57). rCBF was significantly reduced in the impaired group. Cognitive impairment in patients with cardiac failure can be correlated with cerebral ischemia. Stable xenon CT measurement of rCBF in transplant candidates may help identify patients requiring more rapid transplantation to prevent permanent cerebral injury

  9. Role of cerebral blood volume changes in brain specific-gravity measurements

    International Nuclear Information System (INIS)

    Picozzi, P.; Todd, N.V.; Crockard, A.H.

    1985-01-01

    Cerebral blood volume (CBV) was calculated in gerbils from specific-gravity (SG) changes between normal and saline-perfused brains. Furthermore, changes in CBV were investigated during ischemia using carbon-14-labeled dextran (MW 70,000) as an intravascular marker. Both data were used to evaluate the possible error due to a change in CBV on the measurement of ischemic brain edema by the SG method. The methodological error found was 0.0004 for a 100% CBV change. This error is insignificant, being less than the standard deviation in the SG measured for the gerbil cortex. Thus, CBV changes are not responsible for the SG variations observed during the first phase of ischemia. These variations are better explained as an increase of brain water content during ischemia

  10. Survey of blood cultures methods in Italy in 2010

    Directory of Open Access Journals (Sweden)

    Antonio Goglio

    2011-09-01

    Full Text Available Sepsis is a serious clinical condition, associated with high mortality despite advanced modern medical treatment. Traditionally, the detection and identification of bacteria and fungi circulating in the blood-stream is based on blood cultures. A number of factors influence the yield of blood culture, most of them concerning the microbiologist skill and the laboratory organization. In order to collect information about the practices and procedures used for the detection of microrganisms in blood cultures in the italian laboratory (lab, an e-mail with the invitation to participate in the survey was sent to 2000 members of the Italian Association of Clinical Microbiology. Responses were received from 100 lab, located from all over the country (in 18/20 italian regions. The results presented hereby concern specimen collection, culture techniques, rapid identification and susceptibility testing, laboratory organization, relationships with physicians. In summary, most lab use automated systems (96%, the bottles are incubated immediately during public holidays in 72/96 lab (75% and in 49/97 lab at night (50.5%, the lenght of incubation was 5 or 7 days in 93% of the lab, although it is common to extend the incubation period when brucellosis (74 lab, endocarditis (49 lab, systemic mycosis (33 lab is suspected. A wide variety of media are employed for subcultures. All lab process the positive bottles at least once a day, while only in 42 of 81 (51.9% lab the positive blood are processed on holiday. Communication between clinicians and microbiologist include: distribution of specimen collection guidelines (96/100 lab, availability to microbiologist of patients’ clinical situation (77/96 lab, 80.2%, and adding to report the microbiologist’ suggestion (75/98 lab, 76.5%. The results, compared with those collected with a similar questionnaire in 2001, show a greater adherence to guidelines: the number of bottles examined by lab yearly is almost doubled

  11. Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta.

    Science.gov (United States)

    Okamoto, Eiji; Yano, Tetsuya; Miura, Hidekazu; Shiraishi, Yasuyuki; Yambe, Tomoyuki; Mitamura, Yoshinori

    2017-12-01

    We have developed various axial flow blood pumps to realize the concept of the Valvo pump, and we have studied hemodynamic changes under cardiac assistance using an axial flow blood pump in series with the natural heart. In this study, we measured hemodynamic changes of not only systemic circulation but also cerebral circulation and coronary circulation under cardiac support using our latest axial flow blood pump placed in the descending aorta in an acute animal experiment. The axial flow blood pump was installed at the thoracic descending aorta through a left thoracotomy of a goat (43.8 kg, female). When the pump was on, the aortic pressure and aortic flow downstream of the pump increased with preservation of pulsatilities. The pressure drop upstream of the pump caused reduction of afterload pressure, and it may lead to reduction of left ventricular wall stress. However, cerebral blood flow and coronary blood flow were decreased when the pump was on. The axial flow blood pump enables more effective blood perfusion into systemic circulation, but it has the potential risk of blood perfusion disturbance into cerebral circulation and coronary circulation. The results indicate that the position before the coronary ostia might be suitable for implantation of the axial flow blood pump in series with the natural heart to avoid blood perfusion disturbances.

  12. Anxiety and cerebral blood flow during behavioral challenge. Dissociation of central from peripheral and subjective measures

    International Nuclear Information System (INIS)

    Zohar, J.; Insel, T.R.; Berman, K.F.; Foa, E.B.; Hill, J.L.; Weinberger, D.R.

    1989-01-01

    To investigate the relationship between anxiety and regional cerebral blood flow, we administered behavioral challenges to 10 patients with obsessive-compulsive disorder while measuring regional cerebral blood flow with the xenon 133 inhalation technique. Each patient was studied under three conditions: relaxation, imaginal flooding, and in vivo (actual) exposure to the phobic stimulus. Subjective anxiety, obsessive-compulsive ratings, and autonomic measures (heart rate, blood pressure) increased significantly, but respiratory rate and PCO 2 did not change across the three conditions. Regional cerebral blood flow increased slightly (in the temporal region) during imaginal flooding, but decreased markedly in several cortical regions during in vivo exposure, when anxiety was highest by subjective and peripheral autonomic measures. These results demonstrate that intense anxiety can be associated with decreased rather than increased cortical perfusion and that ostensibly related states of anxiety (eg, anticipatory and obsessional anxiety) may be associated with opposite effects on regional cerebral blood flow

  13. Anxiety and cerebral blood flow during behavioral challenge. Dissociation of central from peripheral and subjective measures

    Energy Technology Data Exchange (ETDEWEB)

    Zohar, J.; Insel, T.R.; Berman, K.F.; Foa, E.B.; Hill, J.L.; Weinberger, D.R.

    1989-06-01

    To investigate the relationship between anxiety and regional cerebral blood flow, we administered behavioral challenges to 10 patients with obsessive-compulsive disorder while measuring regional cerebral blood flow with the xenon 133 inhalation technique. Each patient was studied under three conditions: relaxation, imaginal flooding, and in vivo (actual) exposure to the phobic stimulus. Subjective anxiety, obsessive-compulsive ratings, and autonomic measures (heart rate, blood pressure) increased significantly, but respiratory rate and PCO/sub 2/ did not change across the three conditions. Regional cerebral blood flow increased slightly (in the temporal region) during imaginal flooding, but decreased markedly in several cortical regions during in vivo exposure, when anxiety was highest by subjective and peripheral autonomic measures. These results demonstrate that intense anxiety can be associated with decreased rather than increased cortical perfusion and that ostensibly related states of anxiety (eg, anticipatory and obsessional anxiety) may be associated with opposite effects on regional cerebral blood flow.

  14. Measurement of blood pressure, ankle blood pressure and calculation of ankle brachial index in general practice

    DEFF Research Database (Denmark)

    Nexøe, Jørgen; Damsbo, Bent; Lund, Jens Otto

    2012-01-01

    BACKGROUND: Low ankle brachial index (ABI) is a sensitive measure of 'burden' of atherosclerosis, indicating cardiovascular risk of the asymptomatic patient. Conventionally, ABI values......BACKGROUND: Low ankle brachial index (ABI) is a sensitive measure of 'burden' of atherosclerosis, indicating cardiovascular risk of the asymptomatic patient. Conventionally, ABI values...

  15. Novel Methods for Measuring LiDAR

    Science.gov (United States)

    Ayrey, E.; Hayes, D. J.; Fraver, S.; Weiskittel, A.; Cook, B.; Kershaw, J.

    2017-12-01

    The estimation of forest biometrics from airborne LiDAR data has become invaluable for quantifying forest carbon stocks, forest and wildlife ecology research, and sustainable forest management. The area-based approach is arguably the most common method for developing enhanced forest inventories from LiDAR. It involves taking a series of vertical height measurements of the point cloud, then using those measurements with field measured data to develop predictive models. Unfortunately, there is considerable variation in methodology for collecting point cloud data, which can vary in pulse density, seasonality, canopy penetrability, and instrument specifications. Today there exists a wealth of public LiDAR data, however the variation in acquisition parameters makes forest inventory prediction by traditional means unreliable across the different datasets. The goal of this project is to test a series of novel point cloud measurements developed along a conceptual spectrum of human interpretability, and then to use the best measurements to develop regional enhanced forest inventories on Northern New England's and Atlantic Canada's public LiDAR. Similarly to a field-based inventory, individual tree crowns are being segmented, and summary statistics are being used as covariates. Established competition and structural indices are being generated using each tree's relationship to one another, whilst existing allometric equations are being used to estimate diameter and biomass of each tree measured in the LiDAR. Novel metrics measuring light interception, clusteredness, and rugosity are also being measured as predictors. On the other end of the human interpretability spectrum, convolutional neural networks are being employed to directly measure both the canopy height model, and the point clouds by scanning each using two and three dimensional kernals trained to identify features useful for predicting biological attributes such as biomass. Predictive models will be trained and

  16. Two methods to measure granular gas temperature

    Science.gov (United States)

    Chastaing, J.-Y.; Géminard, J.-C.; Naert, A.

    2017-07-01

    Grains are vibrated so as to achieve a granular gas, here regarded as an archetype of a dissipative non equilibrium steady state (NESS). We report on two distinct and concordant experimental measures of the system effective temperature. To do so, a blade fastened to the shaft of a small DC-motor, immersed in the grains, behaves as a driven 1D Brownian rotator, which is used as both actuator and sensor simultaneously. On the one hand, the Gallavotti-Cohen fluctuation theorem, which involves a measure of the asymmetry of the energy exchanges between the rotator and the NESS reservoir, provides a first effective temperature. On the other hand, the fluctuation-dissipation theorem, which involves the relation between the spontaneous fluctuations and the response to a weak perturbation, defines a second, independent, effective temperature. Both methods, even though they are based on drastically different ideas, give nicely concordant results.

  17. Measuring scholarly impact methods and practice

    CERN Document Server

    Rousseau, Ronald; Wolfram, Dietmar

    2014-01-01

    This book is an authoritative handbook of current topics, technologies and methodological approaches that may be used for the study of scholarly impact. The included methods cover a range of fields such as statistical sciences, scientific visualization, network analysis, text mining, and information retrieval. The techniques and tools enable researchers to investigate metric phenomena and to assess scholarly impact in new ways. Each chapter offers an introduction to the selected topic and outlines how the topic, technology or methodological approach may be applied to metrics-related research. Comprehensive and up-to-date, Measuring Scholarly Impact: Methods and Practice is designed for researchers and scholars interested in informetrics, scientometrics, and text mining. The hands-on perspective is also beneficial to advanced-level students in fields from computer science and statistics to information science.

  18. Gravimetric capillary method for kinematic viscosity measurements

    Science.gov (United States)

    Rosenberger, Franz; Iwan, J.; Alexander, D.; Jin, Wei-Qing

    1992-01-01

    A novel version of the capillary method for viscosity measurements of liquids is presented. Viscosity data can be deduced in a straightforward way from mass transfer data obtained by differential weighing during the gravity-induced flow of the liquid between two cylindrical chambers. Tests of this technique with water, carbon tetrachloride, and ethanol suggest that this arrangement provides an accuracy of about +/- 1 percent. The technique facilitates operation under sealed, isothermal conditions and, thus can readily be applied to reactive and/or high vapor pressure liquids.

  19. Statistical analysis of blood pressure measurement errors by oscillometry during surgical operations.

    Science.gov (United States)

    Tao, Guocai; Chen, Yan; Wen, Changyun; Bi, Min

    2011-12-01

    Although a validated oscillometry sphygmomanometer satisfies the accuracy criteria of Advancement of Medical Instrumentation (AAMI), its long-term blood pressure (BP) measurement error during operations remains to be determined. We aim to (a) compare the error range throughout surgical operations with the accuracy criteria of AAMI, and (b) investigate the probabilities of occurrence of abnormal, large errors and clinically meaningful errors. BP level were measured from 270 participants using oscillometry and arterial cannulation (invasive method) in the same BP monitor throughout surgeries. Mean deviation and SD (oscillometry vs. invasive method) were calculated from 6640 sets of data and presented in the Bland-Altman Plots. Also, the average, the largest, and the smallest measurement errors (errormean, errormax, and errormin) per patient were obtained. The probability distributions of the three types of errors were shown using histograms (percentage vs. SD). In addition, the clinically meaningful large errors (≥ 10 mmHg) of the adult patients when their systolic blood pressure (SBP) values were around 90 mmHg were investigated. The mean deviation (1.98 mmHg for SBP and 4.31 mmHg for diastolic blood pressure (DBP) satisfies the AAMI criterion (≤ 5 mmHg), but the SD (14.87 mmHg for SBP and 11.21 mmHg for DBP) exceeds the AAMI criterion (≤ 8 mmHg). The probability of errormax more than 40 mmHg is 14% for SBP and 6% for DBP. The probability of errormean more than 24 mmHg (4.07% for SBP and 1.48% for DBP), and that of errormin more than 24 mmHg (0.37% for SBP and 0.37% for DBP) are all greater than the criterion of 0.26%. The clinically meaningful errors are found in 28.78% of the adult patients. The SD of long-term BP measurement by our oscillometric method during operations exceeds AAMI accuracy criteria. And it is important to be aware of the abnormal large errors and clinically meaningful errors as their probabilities are rather significant. We analyze the

  20. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx of...

  1. Nurse-measured or ambulatory blood pressure in routine hypertension care

    NARCIS (Netherlands)

    Veerman, D. P.; van Montfrans, G. A.

    1993-01-01

    Nurses are considered to evoke less white-coat hypertension, and might therefore be able to estimate average blood pressure as well as and more conveniently than ambulatory monitoring. The objective of the present study was to determine the correspondence between blood pressure measured by a doctor

  2. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  3. Determination of the amplitude and phase relationships between oscillations in skin temperature and photoplethysmography-measured blood flow in fingertips.

    Science.gov (United States)

    Sagaidachnyi, A A; Skripal, A V; Fomin, A V; Usanov, D A

    2014-02-01

    temperature, and define possibilities and limitations of temperature measurements as a method of blood flow assessment in extremities.

  4. Blood flow determination using recursive processing: a digital radiographic method

    International Nuclear Information System (INIS)

    Kruger, R.A.; Bateman, W.; Liu, P.Y.; Nelson, J.A.

    1983-01-01

    Temporal filtration of fluoroscopic video sequences is being used as an alternative to pulsed digital subtraction angiography. Using the same image processing architecture and a slight modification in processing logic a parametric image can be synthesized from such a temporally filtered image sequence in virtual real time, i.e., an image sequence that spans T seconds takes exactly T seconds to process. Off-line computer processing is not required. Initial phantom studies imply that the time to maximum opacification (t/sub max/) can be used to determine absolute and relative blood flow with a high confidence level (r > .989). Phantom and animal examples are presented

  5. Validation of the Parama-Tech PS-501 device for office blood pressure measurement according to the international protocol.

    Science.gov (United States)

    Kikuya, Masahiro; Ohkubo, Takayoshi; Satoh, Michihiro; Hashimoto, Takanao; Hirose, Takuo; Metoki, Hirohito; Obara, Taku; Inoue, Ryusuke; Asayama, Kei; Totsune, Kazuhito; Imai, Yutaka

    2012-01-01

    The PS-501 device (Parama-Tech, Fukuoka, Japan), an automated device for office blood pressure measurement based on the Korotkoff method and designed for professional use in clinical settings, was validated. Consecutive outpatients with hypertension and ≥30 years old at an outpatient hypertension clinic were recruited. According to the European Society of Hypertension protocol, 33 participants were included in the validation study (phase 1, n = 15; phase 2, n = 18). The cuff deflation rate can be selected manually from 2, 3, and 4 mm Hg/beat. The validation was performed with the device deflating at a rate of 2 mm Hg/beat. All blood pressure readings were measured on the left arm. The tested device passed all criteria for both systolic and diastolic blood pressure measurements. The mean (± standard deviation) differences in systolic and diastolic blood pressure between the tested device and the mean of observer readings were -1.9 ± 4.6 and -2.5 ± 2.9 mm Hg, respectively. The PS-501 device for office blood pressure measurement passed all the validation criteria of the European Society of Hypertension and can therefore be recommended for clinical use in an adult population.

  6. Data Based Prediction of Blood Glucose Concentrations Using Evolutionary Methods.

    Science.gov (United States)

    Hidalgo, J Ignacio; Colmenar, J Manuel; Kronberger, Gabriel; Winkler, Stephan M; Garnica, Oscar; Lanchares, Juan

    2017-08-08

    Predicting glucose values on the basis of insulin and food intakes is a difficult task that people with diabetes need to do daily. This is necessary as it is important to maintain glucose levels at appropriate values to avoid not only short-term, but also long-term complications of the illness. Artificial intelligence in general and machine learning techniques in particular have already lead to promising results in modeling and predicting glucose concentrations. In this work, several machine learning techniques are used for the modeling and prediction of glucose concentrations using as inputs the values measured by a continuous monitoring glucose system as well as also previous and estimated future carbohydrate intakes and insulin injections. In particular, we use the following four techniques: genetic programming, random forests, k-nearest neighbors, and grammatical evolution. We propose two new enhanced modeling algorithms for glucose prediction, namely (i) a variant of grammatical evolution which uses an optimized grammar, and (ii) a variant of tree-based genetic programming which uses a three-compartment model for carbohydrate and insulin dynamics. The predictors were trained and tested using data of ten patients from a public hospital in Spain. We analyze our experimental results using the Clarke error grid metric and see that 90% of the forecasts are correct (i.e., Clarke error categories A and B), but still even the best methods produce 5 to 10% of serious errors (category D) and approximately 0.5% of very serious errors (category E). We also propose an enhanced genetic programming algorithm that incorporates a three-compartment model into symbolic regression models to create smoothed time series of the original carbohydrate and insulin time series.

  7. Blood

    Science.gov (United States)

    ... production of red blood cells, including: Iron deficiency anemia. Iron deficiency anemia is the most common type of anemia and ... inflammatory bowel disease are especially likely to have iron deficiency anemia. Anemia due to chronic disease. People with chronic ...

  8. Performance of an app measuring spot quality in dried blood spot sampling

    NARCIS (Netherlands)

    Veenhof, Herman

    2016-01-01

    Introduction: The Dried Blood Spot sampling (DBS) method gives patients and health care workers the opportunity for remote sampling using a drop of blood from a fingerprick on a sampling card which can be send to the laboratory by mail. Laboratory analysts frequently reject DBS samples because of

  9. Measuring density and compressibility of white blood cells and prostate cancer cells by microchannel acoustophoresis

    DEFF Research Database (Denmark)

    Barnkob, Rune; Augustsson, Per; Magnusson, Cecilia

    2011-01-01

    to determine the density and compressibility of individual cells enables the prediction and alteration of the separation outcome for a given cell mixture. We apply the method on white blood cells (WBCs) and DU145 prostate cancer cells (DUCs) aiming to improve isolation of circulating tumor cells from blood......, an emerging tool in the monitoring and characterizing of metastatic cancer....

  10. Portable method of measuring gaseous acetone concentrations.

    Science.gov (United States)

    Worrall, Adam D; Bernstein, Jonathan A; Angelopoulos, Anastasios P

    2013-08-15

    Measurement of acetone in human breath samples has been previously shown to provide significant non-invasive diagnostic insight into the control of a patient's diabetic condition. In patients with diabetes mellitus, the body produces excess amounts of ketones such as acetone, which are then exhaled during respiration. Using various breath analysis methods has allowed for the accurate determination of acetone concentrations in exhaled breath. However, many of these methods require instrumentation and pre-concentration steps not suitable for point-of-care use. We have found that by immobilizing resorcinol reagent into a perfluorosulfonic acid polymer membrane, a controlled organic synthesis reaction occurs with acetone in a dry carrier gas. The immobilized, highly selective product of this reaction (a flavan) is found to produce a visible spectrum color change which could measure acetone concentrations to less than ppm. We here demonstrate how this approach can be used to produce a portable optical sensing device for real-time, non-invasive acetone analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. New method for simultaneous determination of 55Fe and 59Fe in blood serum samples

    International Nuclear Information System (INIS)

    Saukkonen, H.; Uhlenius, R.

    1978-01-01

    Routine methods for the measurement of 55 Fe and 59 Fe activities in biological samples are frequently required in metabolic studies of iron. A new simple method for the simultaneous determination of 59 Fe and 55 Fe concentration in 5 cm 3 samples of blood is described and carefully evaluated. Before the measurement of the activity, organic matter was eliminated by HNO 3 -HClO 4 wet ashing and iron was electroplated onto a copper plate. The accuracy of results was studied by assessing samples, which contained known amounts of radioactivity and determining the counts per nanocurie in each case. The accuracy of the results of 59 Fe and 55 Fe determinations was found to be about 5%. The method has been routinely used to determine iron resorption in patients using the double isotope method. The determination proved to be satisfactory and not too laborious. When performing the yield determination there is a way of detecting and correcting mistakes or incompleteness in different stages of the measurement, thus leading to a high degree of reliability. (T.G.)

  12. Phenomenon of declining blood pressure in elderly - high systolic levels are undervalued with Korotkoff method

    Directory of Open Access Journals (Sweden)

    Elmståhl Sölve

    2011-10-01

    Full Text Available Abstract Background Systolic blood pressure (SBP decline has been reported in octogenarians. The aim was to study if it could be observed while measuring SBP with two methods: Korotkoff (K-BP and Strain-Gauge-Finger-Pletysmography (SG-BP, and which of them were more reliable in expressing vascular burden. Methods A cohort of 703 men from a population of Malmö, Sweden, were included in "Men born in 1914-study" and followed-up at ages: 68 and 81 years. 176 survivors were examined with K-BP and SG-BP at both ages, and 104 of them with Ambulatory Blood Pressure at age 81/82. Ankle Brachial Index (ABI was measured on both occasions, and Carotid Ultrasound at age 81. Results From age 68 to 81, mean K-BP decreased in the cohort with mean 8.3 mmHg, while SG-BP increased with 13.4 mmHg. K-BP decreased in 55% and SG-BP in 31% of the subjects. At age 81, K-BP was lower than SG-BP in 72% of subjects, and correlated to high K-BP at age 68 (r = --.22; p Conclusion In contrast to K-BP, values of SG-BP in octogenarians strongly correlated with Ambulatory Blood Pressure. The SG-BP decline in the last decade was rare, and increasing SG-BP better than K-BP reflected advanced atherosclerosis. It should be aware, that K-BP underdetected 46% of subjects with SG-BP equal/higher than 140 mmHg at age 81, which may lead to biased associations with risk factors due to differential misclassification by age.

  13. A chemiluminescence biochemical oxygen demand measuring method.

    Science.gov (United States)

    Nakamura, Hideaki; Abe, Yuta; Koizumi, Rui; Suzuki, Kyota; Mogi, Yotaro; Hirayama, Takumi; Karube, Isao

    2007-10-17

    A new chemiluminescence biochemical oxygen demand (BOD(CL)) determining method was studied by employing redox reaction between quinone and Baker's yeast. The measurement was carried out by utilizing luminol chemiluminescence (CL) reaction catalyzed by ferricyanide with oxidized quinone of menadione, and Saccharomyces cerevisiae using a batch-type luminometer. In this study, dimethyl sulfoxide was used as a solvent for menadione. After optimization of the measuring conditions, the CL response to hydrogen peroxide in the incubation mixture had a linear response between 0.1 and 100 microM H2O2 (r2=0.9999, 8 points, n=3, average of relative standard deviation; R.S.D.(av)=4.22%). Next, a practical relationship between the BOD(CL) response and the glucose glutamic acid concentration was obtained over a range of 11-220 mg O2 L(-1) (6 points, n=3, R.S.D.(av) 3.71%) with a detection limit of 5.5 mg O2 L(-1) when using a reaction mixture and incubating for only 5 min. Subsequently, the characterization of this method was studied. First, the BOD(CL) responses to 16 pure organic substances were examined. Second, the influences of chloride ions, artificial seawater, and heavy metal ions on the BOD(CL) response were investigated. Real sample measurements using river water were performed. Finally, BOD(CL) responses were obtained for at least 8 days when the S. cerevisiae suspension was stored at 4 degrees C (response reduction, 69.9%; R.S.D. for 5 testing days, 18.7%). BOD(CL) responses after 8 days and 24 days were decreased to 69.9% and 35.8%, respectively, from their original values (R.S.D. for 8 days involving 5 testing days, 18.7%).

  14. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-10-01

    Two different radioactive microspheres ( U Ce and UWSc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures.

  15. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    International Nuclear Information System (INIS)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-01-01

    Two different radioactive microspheres ( 141 Ce and 46 Sc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures

  16. Modelling blood safety

    NARCIS (Netherlands)

    Janssen, M.P.

    2010-01-01

    This thesis describes the development and application of methods and models to support decision making on safety measures aimed at preventing the transmission of infections by blood donors. Safety measures refer to screening tests for blood donors, quarantine periods for blood plasma, or methods for

  17. Overview of revised measures to prevent malaria transmission by blood transfusion in France.

    Science.gov (United States)

    Garraud, O; Assal, A; Pelletier, B; Danic, B; Kerleguer, A; David, B; Joussemet, M; de Micco, P

    2008-10-01

    Plasmodial transmission by blood donation is rare in non-endemic countries, but a very serious complication of blood transfusion. The French national blood service (Etablissement Français du Sang and Centre de Transfusion sanguine des Armees) intended to revise the measures to strengthen blood safety with regard to Plasmodiae as transmissible pathogens. To limit the risk of transmission during infusion, serious additive measures have been taken for more than a decade in France, which is the European country with the highest rate of exposure to imported plasmodial infections or malaria. These measures were revised and strengthened after the occurrence of a lethal transfusion-transmitted infection in 2002, but did not prevent another occurrence in 2006. This report examines the weaknesses of the systems and aims at emphasizing the safety measures already taken and addresses issues to best respond to that risk.

  18. Tomographic cerebral blood flow measurement during carotid surgery

    DEFF Research Database (Denmark)

    Rathenborg, Lisbet Knudsen; Vorstrup, Sidsel; Olsen, K S

    1994-01-01

    surgery and performing single photon emission computer tomography (SPECT) scanning shortly after the operation thereby pictures rCBF at the time of injection. DESIGN: Ongoing prospective study. SETTINGS: Departments of Vascular Surgery, Neurology and Anaesthesiology, University Hospital, Rigshospitalet...... carotid surgery. This method may serve as a reference tool in future research on intraoperative cerebral haemodynamics....

  19. Use of Blood-soaked Cellulose Filter Paper for Measuring Carbon and Nitrogen Stable Isotopes.

    Science.gov (United States)

    O'Hara, Todd M; Templeton, Megan; Castellini, J Margaret; Wells, Randall; Beckmen, Kimberlee; Berner, James

    2018-04-01

      We explored the use of filter paper soaked in whole blood for measuring carbon (C) and nitrogen (N) stable isotopes, often used in feeding ecology or diet studies, to better understand drivers of exposure to contaminants. Our results showed no statistically or biologically relevant differences in C and N stable isotope measures between our gold standard (whole blood with anticoagulant) and eluates from processed, blood-soaked filter paper. Our data supported the effectiveness of using filter paper for assessing C and N stable isotopes in blood to address feeding ecology and other uses. The ease of sampling and processing should allow blood-soaked filter paper to be used in sampling of live (e.g., captured, stranded) and lethally taken (e.g., hunter-killed) wild vertebrates.

  20. Simultaneously Measured Interarm Blood Pressure Difference and Stroke: An Individual Participants Data Meta-Analysis.

    Science.gov (United States)

    Tomiyama, Hirofumi; Ohkuma, Toshiaki; Ninomiya, Toshiharu; Mastumoto, Chisa; Kario, Kazuomi; Hoshide, Satoshi; Kita, Yoshikuni; Inoguchi, Toyoshi; Maeda, Yasutaka; Kohara, Katsuhiko; Tabara, Yasuharu; Nakamura, Motoyuki; Ohkubo, Takayoshi; Watada, Hirotaka; Munakata, Masanori; Ohishi, Mitsuru; Ito, Norihisa; Nakamura, Michinari; Shoji, Tetsuo; Vlachopoulos, Charalambos; Yamashina, Akira

    2018-04-09

    We conducted individual participant data meta-analysis to examine the validity of interarm blood pressure difference in simultaneous measurement as a marker to identify subjects with ankle-brachial pressure index blood pressure difference >5 mm Hg as being associated with a significant odds ratio for the presence of ankle-brachial pressure index blood pressure difference >15 mm Hg was associated with a significant Cox stratified adjusted hazard ratio for subsequent stroke (hazard ratio, 2.42; 95% confidence interval, 1.27-4.60; P blood pressure differences, measured simultaneously in both arms, may be associated with vascular damage in the systemic arterial tree. These differences may be useful for identifying subjects with an ankle-brachial pressure index of blood pressure in both arms at the first visit. © 2018 American Heart Association, Inc.

  1. Prognostic value of blood pressure measured during hospitalization after acute myocardial infarction: an insight from survival trials

    DEFF Research Database (Denmark)

    Yap, Yee Guan; Duong, Trinh; Bland, J Martin

    2007-01-01

    , CAMIAT, SWORD, TRACE and DIAMOND-MI studies with left ventricular ejection fraction less than 40% or asymptomatic ventricular arrhythmia surviving more than 45 days after MI were pooled. Systolic and diastolic blood pressures and pulse pressures were measured soon after MI (median 6 days, range 0-53 days...... diastolic blood pressure significantly increased the risk of all-cause mortality (HR 0.87, 95% CI 0.77-0.98; P = 0.02) and arrhythmic mortality (HR 0.80, 95% CI 0.68-0.93; P = 0.005). CONCLUSION: In post-MI patients with left ventricular ejection fraction less than 40% or asymptomatic ventricular arrhythmia......BACKGROUND: The prognostic value of blood pressure measured during hospitalization after acute myocardial infarction (MI) has not been investigated, particularly with regard to arrhythmic death. METHODS: A total of 3311 placebo patients (2612 men, median age 64 years; range 23-92) from the EMIAT...

  2. Characterization of a Gas-Purge Method to Access 11C-Carbon-Dioxide Radioactivity in Blood

    International Nuclear Information System (INIS)

    Ng, Y.; Green, M.A.

    2014-01-01

    Carbon-11 (t 1/2 : 20 minutes) labeled radiotracers, such as 11 C-acetate and 11 C-palmitate are widely used in positron emission tomography (PET) for noninvasive evaluation of myocardial metabolism under varied physiological conditions. These tracers are attractive probes of tissue physiology, because they are simply radiolabeled versions of the native biochemical substrates. One of the major metabolites generated by these tracers upon the administration is 11 CO 2 produced via the citric acid cycle. In quantitative modeling of 11 C-acetate and 11 C-palmitate PET data, the fraction of blood 11 C radioactivity present as 11 CO 2 needs to be measured to obtain a correct radiotracer arterial input function. Accordingly, the literature describes a method whereby the total blood 11 C-activity is counted in blood samples treated with base solution, while the fraction of 11 CO 2 is measured after the blood is treated with acid followed by a 10 minutes gas-purge. However, a detailed description of the experimental validation of this method was not provided. The goal of this study was to test the reliability of a 10-minute gas purging method used to assay 11 CO 2 radioactivity in blood. (author)

  3. Fingerprints as an Alternative Method to Determine ABO and Rh Blood Groups.

    Science.gov (United States)

    Chaudhary, Sonam; Deuja, Sajana; Alam, Munna; Karmacharya, Poonam; Mondal, Monami

    2017-01-01

    Blood grouping is conventionally done with invasive method by taking blood samples. The objective of this study is to determine blood group with uninvasive procedure by taking fingerprints of the participants and know the associations between their fingerprints and blood groups. Seven hundred participants of both genders with no any age limitation from Manipal Teaching Hospital and Manipal College of Medical Sciences were randomly selected. The blood grouping was done by cross reacting blood sample with the antibodies. The fingerprints were taken with the help of stamp pad imprinting the finger ridges over A4 size white papers. The loop, whorl and arch patterns were studied. O+ve blood group 224 (32%) was most prevalent among 700 participants. The loop pattern was highly distributed 3708 (53%) in all blood groups except in A-ve blood group with highest distribution of whorl 20 (40%). The mean comparisons of specific fingerprint in total and also in individual fingers with different ABO and ABO-Rh blood groups showed no any statistical association with P>0.05. However, the loop distribution in individual finger was highest in right middle finger (M) of B-ve blood group 5 (10%). The whorl distribution in individual finger was highest in right index (I), left thumb (T) and left ring (R) fingers of AB+ve blood group 20 (5.5% each). Similarly, the arch distribution was highest in right index fingers of A-ve blood group 3 (6%). The mean comparison of different fingerprints with ABO and Rh blood groups showed no significant statistical association concluding fingerprints cannot be used for blood grouping.

  4. Whole blood treated with riboflavin and ultraviolet light: quality assessment of all blood components produced by the buffy coat method.

    Science.gov (United States)

    Schubert, Peter; Culibrk, Brankica; Karwal, Simrath; Serrano, Katherine; Levin, Elena; Bu, Daniel; Bhakta, Varsha; Sheffield, William P; Goodrich, Raymond P; Devine, Dana V

    2015-04-01

    Pathogen inactivation (PI) technologies are currently licensed for use with platelet (PLT) and plasma components. Treatment of whole blood (WB) would be of benefit to the blood banking community by saving time and costs compared to individual component treatment. However, no paired, pool-and-split study directly assessing the impact of WB PI on the subsequently produced components has yet been reported. In a "pool-and-split" study, WB either was treated with riboflavin and ultraviolet (UV) light or was kept untreated as control. The buffy coat (BC) method produced plasma, PLT, and red blood cell (RBC) components. PLT units arising from the untreated WB study arm were treated with riboflavin and UV light on day of production and compared to PLT concentrates (PCs) produced from the treated WB units. A panel of common in vitro variables for the three types of components was used to monitor quality throughout their respective storage periods. PCs derived from the WB PI treatment were of significantly better quality than treated PLT components for most variables. RBCs produced from the WB treatment deteriorated earlier during storage than untreated units. Plasma components showed a 3% to 44% loss in activity for several clotting factors. Treatment of WB with riboflavin and UV before production of components by the BC method shows a negative impact on all three blood components. PLT units produced from PI-treated WB exhibited less damage compared to PLT component treatment. © 2014 AABB.

  5. Micromethod for measuring hexachlorophene in whole blood by gas-liquid chromatography.

    Science.gov (United States)

    Dodson, W E; Tyrala, E E; Hillman, R E

    1977-06-01

    We describe a micromethod for measuring hexachlorophene by use of gas-liquid chromatography with a 63Ni electron capture detector. The procedure requires 100 micronl of blood for extractions of hexachlorophene, and dichlorophene is added as an internal standard. CV is 3.4% over the concentration range of 500 to 1300 microng of hexachlorophene per liter of whole blood. This procedure permits repeated measurements of hexachlorophene in newborns who are being washed with soap containing hexachlorophene.

  6. School based screening for hypothyroidism in Down's syndrome by dried blood spot TSH measurement

    OpenAIRE

    Noble, S; Leyland, K; Findlay, C; Clark, C; Redfern, J; Mackenzie, J; Girdwood, R; Donaldson, M

    2000-01-01

    OBJECTIVE—To determine the feasibility of annual hypothyroid screening of children with Down's syndrome by measuring thyroid stimulating hormone (TSH) on dried blood spots at school, and to describe the outcome in positive children.
DESIGN—Establishment of a register of school children with Down's syndrome, and procedures for obtaining permission from parents, annual capillary blood samples, TSH measurement, and clinical assessment of children with TSH values > 10 mU/litr...

  7. Measurement of capillary blood glucose concentrations by pet owners: a new tool in the management of diabetes mellitus.

    Science.gov (United States)

    Casella, Martina; Wess, Gerhard; Reusch, Claudia E

    2002-01-01

    Recently a new method for capillary blood sampling from the ears of dogs and cats was described, which allows the measurement of glucose concentration by means of portable glucose meters. The authors of this report evaluated the suitability of this method for use by pet owners and the potential technical problems. The owners of seven healthy dogs and seven healthy cats were asked to perform two glucose curves (measuring blood glucose concentration every 2 hours for a total of 12 hours). All dog owners and three cat owners were able to perform a reliable blood glucose curve. The most frequently encountered problems were inadequate formation of a blood drop due to excessive digital pressure on the pinna, repeatedly depressing the plunger of the lancet device instead of allowing the negative pressure to slowly build up, and failure to fill the test strip up to the mark. The authors conclude that these steps of the procedure need to be stressed during technique demonstration and that home monitoring of blood glucose concentrations may serve as a new tool in the management of diabetic dogs and cats.

  8. Measuring ambiguity in HLA typing methods.

    Directory of Open Access Journals (Sweden)

    Vanja Paunić

    Full Text Available In hematopoietic stem cell transplantation, donor selection is based primarily on matching donor and patient HLA genes. These genes are highly polymorphic and their typing can result in exact allele assignment at each gene (the resolution at which patients and donors are matched, but it can also result in a set of ambiguous assignments, depending on the typing methodology used. To facilitate rapid identification of matched donors, registries employ statistical algorithms to infer HLA alleles from ambiguous genotypes. Linkage disequilibrium information encapsulated in haplotype frequencies is used to facilitate prediction of the most likely haplotype assignment. An HLA typing with less ambiguity produces fewer high-probability haplotypes and a more reliable prediction. We estimated ambiguity for several HLA typing methods across four continental populations using an information theory-based measure, Shannon's entropy. We used allele and haplotype frequencies to calculate entropy for different sets of 1,000 subjects with simulated HLA typing. Using allele frequencies we calculated an average entropy in Caucasians of 1.65 for serology, 1.06 for allele family level, 0.49 for a 2002-era SSO kit, and 0.076 for single-pass SBT. When using haplotype frequencies in entropy calculations, we found average entropies of 0.72 for serology, 0.73 for allele family level, 0.05 for SSO, and 0.002 for single-pass SBT. Application of haplotype frequencies further reduces HLA typing ambiguity. We also estimated expected confirmatory typing mismatch rates for simulated subjects. In a hypothetical registry with all donors typed using the same method, the entropy values based on haplotype frequencies correspond to confirmatory typing mismatch rates of 1.31% for SSO versus only 0.08% for SBT. Intermediate-resolution single-pass SBT contains the least ambiguity of the methods we evaluated and therefore the most certainty in allele prediction. The presented measure

  9. Comparison of the Histopaque-1119 method with the Plasmagel method for separation of blood leukocytes for cytomegalovirus isolation.

    OpenAIRE

    Slifkin, M; Cumbie, R

    1992-01-01

    Histopaque-1119 (Sigma Chemical Co., St. Louis, Mo.) and Plasmagel (Cellular Products, Inc., Buffalo, N.Y.) were compared as density gradient separation reagents for the separation of polymorphonuclear leukocytes and mononuclear cells from blood from the isolation of cytomegalovirus (CMV). Of 200 peripheral blood specimens examined, CMV was recovered from 51 by both methods. The time of detection of immunofluorescent sites or a cytopathic effect associated with CMV was similar by each method....

  10. A modified method for the in vivo labeling of red blood cells with /sup 99m/Tc: concise communication

    International Nuclear Information System (INIS)

    Callahan, R.J.; Froelich, J.W.; McKusick, K.A.; Leppo, J.; Strauss, H.W.

    1982-01-01

    The rate of incorporation of /sup 99m/Tc into red blood cells pretinned in vivo was measured by collecting blood samples in stannous DTPA solution, which served as a competing ligand for /sup 99m/Tc. This collection technique permitted a measurement of high-affinity red-cell labeling efficiency at the instant of sampling. At 0.5 min after injection only 62% of technetium is tightly bound to the red cell; this rises to 94.5% at 10 min. Based on the graded labeling of the red cells, the in vivo labeling procedure was modified by isolating pertechnetate and red blood cells tinned in vivo in a syringe during the first 10 min of labeling. The pertechnetate is thus prevented from distributing to extravascular compartments, and 90% of the injected /sup 99m/Tc is firmly bound to red blood cells at the time of injection. In a series of 23 patients, seven were tested with the in vivo method and seven with the modified in vivo method, and nine patients were tested with each method on separate occasions. A decrease in gastric activity and improved image quality were found with the modified method compared with the standard method of in vivo red-cell labeling

  11. Measurements of blood pressure with various techniques in daily practice: uncertainty in diagnosing office hypertension with short-term in-hospital registration of blood pressure

    NARCIS (Netherlands)

    Braun, H. J.; Rabouw, H.; Werner, H.; van Montfrans, G. A.; de Stigter, C.; Zwinderman, A. H.

    1999-01-01

    To predict blood pressure outside the clinic from a short-term in-hospital registration for patients referred for ambulatory blood pressure monitoring (ABPM) with special attention to office hypertension. A series of measurements of blood pressure was performed by the same technician for 187

  12. A method for red blood cell biotinylation in a closed system

    NARCIS (Netherlands)

    de Back, Djuna Z.; Vlaar, Richard; Beuger, Boukje; Daal, Brunette; Lagerberg, Johan; Vlaar, Alexander P. J.; de Korte, Dirk; van Kraaij, Marian; van Bruggen, Robin

    2018-01-01

    Several circumstances require the accurate measurement of red blood cell (RBC) survival and clearance, such as determination of posttransfusion recovery of stored RBCs to investigate the effect of new additive solutions. To this end, biotin as a marker of RBCs to track donor RBCs in the blood of the

  13. Cerebral blood volume measured with inhaled C15O and positron emission tomography

    International Nuclear Information System (INIS)

    Martin, W.R.; Powers, W.J.; Raichle, M.E.

    1987-01-01

    Local cerebral blood volume (CBV) has been measured previously with inhaled 11 CO and positron emission tomography (PET). The model used assumes that equilibrium in tracer concentration has occurred between arterial and systemic venous blood before the PET measurement is made. To verify that this model may be used with the much shorter half-lived C 15 O, we have simultaneously measured arterial and venous blood radioactivity following C 15 O inhalation. Equilibrium occurred 95 +/- 39 s after inhalation (n = 7). If the PET measurement is commenced prior to arteriovenous equilibrium, significant errors occur in calculated CBV. These data indicate that C 15 O may be used as a tracer for CBV measurement provided that emission data collection commences at approximately 120 s after inhalation. Strict quality control measures must be maintained to minimize the contamination of administered C 15 O with 15 O-labeled CO 2

  14. Measurement of blood pressure for the diagnosis and management of hypertension in different ethnic groups: one size fits all.

    Science.gov (United States)

    Gill, Paramjit; Haque, M Sayeed; Martin, Una; Mant, Jonathan; Mohammed, Mohammed A; Heer, Gurdip; Johal, Amanpreet; Kaur, Ramandeep; Schwartz, Claire; Wood, Sally; Greenfield, Sheila M; McManus, Richard J

    2017-02-08

    Hypertension is a major risk factor for cardiovascular disease and prevalence varies by ethnic group. The diagnosis and management of blood pressure are informed by guidelines largely based on data from white populations. This study addressed whether accuracy of blood pressure measurement in terms of diagnosis of hypertension varies by ethnicity by comparing two measurement modalities (clinic blood pressure and home monitoring) with a reference standard of ambulatory BP monitoring in three ethnic groups. Cross-sectional population study (June 2010 - December 2012) with patients (40-75 years) of white British, South Asian and African Caribbean background with and without a previous diagnosis of hypertension recruited from 28 primary care practices. The study compared the test performance of clinic BP (using various protocols) and home-monitoring (1 week) with a reference standard of mean daytime ambulatory measurements using a threshold of 140/90 mmHg for clinic and 135/85 mmHg for out of office measurement. A total of 551 participants had complete data of whom 246 were white British, 147 South Asian and 158 African Caribbean. No consistent difference in accuracy of methods of blood pressure measurement was observed between ethnic groups with or without a prior diagnosis of hypertension: for people without hypertension, clinic measurement using three different methodologies had high specificity (75-97%) but variable sensitivity (33-65%) whereas home monitoring had sensitivity of 68-88% and specificity of 64-80%. For people with hypertension, detection of a raised blood pressure using clinic measurements had sensitivities of 34-69% with specificity of 73-92% and home monitoring had sensitivity (81-88%) and specificity (55-65%). For people without hypertension, ABPM remains the choice for diagnosing hypertension compared to the other modes of BP measurement regardless of ethnicity. Differences in accuracy of home monitoring and clinic monitoring (higher sensitivity

  15. Regional cerebral blood flow in Parkinson's disease measured with N-isopropyl-p-[123I]iodoamphetamine (IMP) SPECT

    International Nuclear Information System (INIS)

    Odano, Ikuo; Nishihara, Mamiko; Hayashi, Hiroko; Higuchi, Shoichi; Sakai, Kunio; Ishikawa, Atsushi; Ibayashi, Katsuhiko.

    1992-01-01

    N-isopropyl-p-[ 123 I]iodoamphetamine (IMP) SPECT studies were performed on 21 patients (13 females; 45-73 yrs) with idiopathic Parkinson's disease (PD) and 10 age-matched normal controls (39-69 yrs). Regional cerebral blood flow (rCBF) was quantitatively measured by the arterial blood sampling method. When compared with normal controls, global CBF, and rCBF in the frontal cortex and in the basal ganglia were reduced 22.1% (p 123 I-IMP SPECT imaging is useful for evaluation and follow-up of patients with PD. (author)

  16. Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs.

    Science.gov (United States)

    Johnson, Beth M; Fry, Michael M; Flatland, Bente; Kirk, Claudia A

    2009-12-01

    To compare blood glucose concentrations measured with 2 portable blood glucose meters (PBGMs) validated for use in dogs (PBGM-D) and humans (PBGM-H) and an automated chemistry analyzer. Validation study. 92 samples of fresh whole blood and plasma from 83 dogs with various diseases. Each PBGM was used to measure whole blood glucose concentration, and the automated analyzer was used to measure plasma glucose concentration. Passing-Bablok linear regression and Bland-Altman plots were used to determine correlations and bias between the PBGMs and the automated analyzer. Calculated acceptability limits based on combined inherent instrument imprecision were used with Bland-Altman plots to determine agreement. Clinical relevance was assessed via error grid analysis. Although correlation between results of both PBGMs and the standard analyzer was > 0.90, disagreement was greater than could be explained by instrument imprecision alone. Mean difference between PBGM-H and chemistry-analyzer values was -15.8 mg/dL. Mean difference between PBGM-D and chemistry-analyzer values was 2.4 mg/dL. Linear regression analysis revealed proportional bias of PBGM-H (greater disagreement at higher glucose concentrations); no proportional bias was detected for PBGM-D. No constant bias was detected for either PBGM. Error grid analysis revealed all measurements from both PBGMs were within zones without an anticipated effect on clinical outcome. Neither PBGM had exact agreement with the automated analyzer; however, the disagreement detected did not have serious clinical consequences. Our findings stressed the importance of using the same device for monitoring trends in dogs and using instrument-specific reference ranges.

  17. Burnup measuring method for nuclear fuel substances

    International Nuclear Information System (INIS)

    Kobayashi, Iwao.

    1979-01-01

    Purpose: To enable non-destructive measurement for the amounts of fissile nucleides contained in nuclear fuel substances by the use of the difference in neutron spectra. Method: Neutrons generated from a neutron source are irradiated to a nuclear fuel substance, the neutrons generated from the nuclear fission reactions in the nuclear fuel substance are identified as epithermal neutrons and the neutrons from the neutron source as thermal neutrons and only the epithermal neutrons are detected to thereby measure the amounts of fissile neucleides in the nuclear fuel substances. For example, a neutron source is provided movably on one side of fuel assemblies placed in water and a neutron detector is situated on the other side by way of gamma-ray shield made of lead. The neutron detector is covered with a thermal neutron-absorbing substance such as cadmium and boron at the outer circumference so that only the epithermal neutrons can permeate therethrough. A high sensitivity detector for thermal neutron are used for improving the detecting efficiency, and the epithermal neutrons are introduced into hydrogen-containing substances such as paraffins to be detected as thermal neutrons. (Kawakami, Y.)

  18. Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections.

    Directory of Open Access Journals (Sweden)

    Anne J M Loonen

    Full Text Available For patients suffering from bloodstream infections (BSI molecular diagnostics from whole blood holds promise to provide fast and adequate treatment. However, this approach is hampered by the need of large blood volumes. Three methods for pathogen DNA isolation from whole blood were compared, i.e. an enzymatic method (MolYsis, 1-5 ml, the novel non-enzymatic procedure (Polaris, 1-5 ml, and a method that does not entail removal of human DNA (Triton-Tris-EDTA EasyMAG, 200 µl. These methods were evaluated by processing blood spiked with 0-1000 CFU/ml of Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans. Downstream detection was performed with real-time PCR assays. Polaris and MolYsis processing followed by real-time PCRs enabled pathogen detection at clinically relevant concentrations of 1-10 CFU/ml blood. By increasing sample volumes, concurrent lower cycle threshold (Ct values were obtained at clinically relevant pathogen concentrations, demonstrating the benefit of using larger blood volumes. A 100% detection rate at a concentration of 10 CFU/ml for all tested pathogens was obtained with the Polaris enrichment, whereas comparatively lower detection rates were measured for MolYsis (50-67% and EasyMAG (58-79%. For the samples with a concentration of 1 CFU/ml Polaris resulted in most optimal detection rates of 70-75% (MolYsis 17-50% and TTE-EasyMAG 20-36%. The Polaris method was more reproducible, less labour intensive, and faster (45 minutes (including Qiagen DNA extraction vs. 2 hours (MolYsis. In conclusion, Polaris and MolYsis enrichment followed by DNA isolation and real-time PCR enables reliable and sensitive detection of bacteria and fungi from 5 ml blood. With Polaris results are available within 3 hours, showing potential for improved BSI diagnostics.

  19. Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets

    Science.gov (United States)

    Diop, Mamadou; Tichauer, Kenneth M.; Elliott, Jonathan T.; Migueis, Mark; Lee, Ting-Yim; Lawrence, Keith St.

    2010-09-01

    A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF), resulting in further injury. Since current noninvasive methods used in the clinic can only assess blood flow indirectly, the goal of this research is to develop an optical technique for measuring absolute CBF. A time-resolved near-infrared (TR-NIR) apparatus is built and CBF is determined by a bolus-tracking method using indocyanine green as an intravascular flow tracer. As a first step in the validation of this technique, CBF is measured in newborn piglets to avoid signal contamination from extracerebral tissue. Measurements are acquired under three conditions: normocapnia, hypercapnia, and following carotid occlusion. For comparison, CBF is concurrently measured by a previously developed continuous-wave NIR method. A strong correlation between CBF measurements from the two techniques is revealed with a slope of 0.79+/-0.06, an intercept of -2.2+/-2.5 ml/100 g/min, and an R2 of 0.810+/-0.088. Results demonstrate that TR-NIR can measure CBF with reasonable accuracy and is sensitive to flow changes. The discrepancy between the two methods at higher CBF could be caused by differences in depth sensitivities between continuous-wave and time-resolved measurements.

  20. Blood Contamination in Saliva: Impact on the Measurement of Salivary Oxidative Stress Markers

    Directory of Open Access Journals (Sweden)

    Natália Kamodyová

    2015-01-01

    Full Text Available Salivary oxidative stress markers represent a promising tool for monitoring of oral diseases. Saliva can often be contaminated by blood, especially in patients with periodontitis. The aim of our study was to examine the impact of blood contamination on the measurement of salivary oxidative stress markers. Saliva samples were collected from 10 healthy volunteers and were artificially contaminated with blood (final concentration 0.001–10%. Next, saliva was collected from 12 gingivitis and 10 control patients before and after dental hygiene treatment. Markers of oxidative stress were measured in all collected saliva samples. Advanced oxidation protein products (AOPP, advanced glycation end products (AGEs, and antioxidant status were changed in 1% blood-contaminated saliva. Salivary AOPP were increased in control and patients after dental treatment (by 45.7% and 34.1%, p<0.01. Salivary AGEs were decreased in patients after microinjury (by 69.3%, p<0.001. Salivary antioxidant status markers were decreased in both control and patients after dental treatment (p<0.05 and p<0.01. One % blood contamination biased concentrations of salivary oxidative stress markers. Saliva samples with 1% blood contamination are visibly discolored and can be excluded from analyses without any specific biochemic detection of blood constituents. Salivary markers of oxidative stress were significantly altered in blood-contaminated saliva in control and patients with gingivitis after dental hygiene treatment.

  1. Weathering: methods and techniques to measure

    Science.gov (United States)

    Lopez-Arce, P.; Zornoza-Indart, A.; Alvarez de Buergo, M.; Fort, R.

    2012-04-01

    Surface recession takes place when weathered material is removed from the rocks. In order to know how fast does weathering and erosion occur, a review of several methods, analyses and destructive and non-destructive techniques to measure weathering of rocks caused by physico-chemical changes that occur in bedrocks due to salt crystallization, freezing-thaw, thermal shock, influence of water, wind, temperature or any type of environmental agent leading to weathering processes and dev