  1. Noninvasive methods of measuring bone blood perfusion

    OpenAIRE

    Dyke, J. P.; Aaron, R.K.

    2010-01-01

    Measurement of bone blood flow and perfusion characteristics in a noninvasive and serial manner would be advantageous in assessing revascularization after trauma and the possible risk of avascular necrosis. Many disease states, including osteoporosis, osteoarthritis, and bone neoplasms, result in disturbed bone perfusion. A causal link between bone perfusion and remodeling has shown its importance in sustained healing and regrowth following injury. Measurement of perfusion and permeability wi...

  2. Methods for measurement of cerebral blood flow in man

    DEFF Research Database (Denmark)

    Lassen, N A

    1976-01-01

    A survey of the currently available methods for the measurement of cerebral blood flow in man is given. Many of the clinically important brain diseases such as tumors, stroke, brain trauma or epilepsy entail focal or regional flow alterations. Therefore a special emphasis is placed on methods all...

  3. Methods for blood flow measurements using ultrasound contrast agents

    Science.gov (United States)

    Fowlkes, J. Brian

    2003-10-01

    Blood flow measurements using ultrasound contrast agents are being investigated for myocardial perfusion and more recently in other organ systems. The methods are based largely on the relative increase in echogenicity due to the concentration of bubbles present in the ultrasound beam. In the simplest form, regional differences in blood volume can be inferred but the possibility exists to extract perfusion from the transit of contrast agent through tissue. Perfusion measurements rely on determining the flux of blood through a tissue volume and as such require knowledge of the fractional blood volume (FBV), i.e., ml blood/g tissue and the rate of exchange, commonly measured as the mean transit time (MTT). This presentation will discuss methods of determining each of these values and their combination to estimate tissue perfusion. Underlying principles of indicator-dilution theory will be provided in the context of ultrasound contrast agents. Current methods for determining MTT will include imaging of the intravenous bolus, in-plane contrast disruption with interval and real-time contrast recovery imaging, and control of contrast agent flow using arterial disruption (contrast interruption). The advantages and limitations of the methods will be examined along with current applications. [Work supported in part by NIH.

  4. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H;

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  5. A blood pressure measurement method based on synergetics theory

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    <正>The principle for blood pressure measurement using pulse transit time is introduced in this paper.And the math model of synergetics theory is studied in detail.The synergetics theory is applied in the analysis of blood pressure measurement data.The simulation results show that the application of synergetics theory is helpful to judge the normal blood pressure,and the accuracy is up to 80%.

  6. Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss.

    Science.gov (United States)

    Vitello, Dominic J; Ripper, Richard M; Fettiplace, Michael R; Weinberg, Guy L; Vitello, Joseph M

    2015-01-01

    Purpose. The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study's purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods. 50 µL of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student's unpaired, one-tailed t-test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results. The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t-test showed P = 0.2269 and R (2) = 0.03154. The hematocrit values ranged from 24% to 48%. The linear regression R (2) value was 0.1767. Conclusions. The R (2) value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

  7. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  8. Measurement of temperature decrease caused by blood flow in focused ultrasound irradiation by thermal imaging method

    Science.gov (United States)

    Tsuchiya, Takenobu; Hatano, Yuichi; Mori, Yashunori; Shen, Rakushin; Endoh, Nobuyuki

    2016-07-01

    In this study, to estimate the local temperature changes caused by a thick blood vessel, the temperature distribution in a tissue phantom with a thick blood vessel during focused ultrasound irradiation was measured by a thermal imaging method. The blood flow rate in the simulated blood vessel was varied and the relationship between flow rate and temperature decrease was examined. The phantom using the thermal imaging method is divided into two parts, and the increases in temperature distribution as a function of blood flow rate are measured using a thermocamera under constant ultrasound irradiation. The irradiation conditions of ultrasound waves were a central frequency of 1 MHz, a wave number length of 200 cycles, and a duty ratio of 0.2. The irradiation duration was 5 min, and the ultrasound intensity I SPTA was 36 W/cm2. The amount of temperature decrease caused by the cooling effect of blood flow increased with the blood flow rate and it became constant at a certain threshold of blood flow rate. The threshold of blood flow rate is about 250 ml/min.

  9. Plasma concentrations of blood coagulation factor VII measured by immunochemical and amidolytic methods

    DEFF Research Database (Denmark)

    Bladbjerg, E-M; Gram, J; Jespersen, J

    2000-01-01

    Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII......:Ag) or estimated with an amidolytic method (FVII:Am). We have investigated whether FVII:Am is a valuable alternative to FVII:Ag. FVII:Ag and FVII:Am were measured in 147 plasma samples from blood donors, patients on oral anticoagulant therapy, postmenopausal women on hormone replacement therapy, in postprandial...

  10. Blood pressure measurement

    Science.gov (United States)

    Diastolic blood pressure; Systolic blood pressure; Blood pressure reading; Measuring blood pressure ... or your health care provider will wrap the blood pressure cuff snugly around your upper arm. The lower ...

  11. A Surface Heat Disturbance Method for Measuring Local TIssue Blood Perfusion Rate

    Institute of Scientific and Technical Information of China (English)

    PengJianshu; TianYongquan

    1996-01-01

    A non-damage method for measuring local tissue blood perfusion rate by surface heat disturbance and its two special embodiments for realizing this measurement are presented in this paper,In the derivation of mathematical model,the Pennes equation is used,and two parameters which are very diffcult to be known-the arterial blood temperature Ta and the metabolic heat generation rate qm,have been eliminated.So if has provided a feasible basis for application.In this paper,the performance and the adaptable condition of the measurement method and its structure peculiarities are discussed over a wide variety of parameters.Moreover,the effectiveness of the measurement method has been demonstrated by means of the quantitative measurement of tissue in vitro,the comparative measurement of animal under artificial perfusion and the dependence measurement in human body.

  12. [Accuracy of the oscillometric method to measure blood pressure in children

    Science.gov (United States)

    Rego Filho, E A; Mello, S F; Silva, C R; Vituri, D W; Bazoni, E; Gordan, L N

    1999-01-01

    OBJECTIVE: The aim of this study is to analyze the substitution of the standard auscultatory method by the oscillometric blood pressure monitor, independently of the validity of the intraarterial blood pressure measurement. The accuracy of the automatic oscillometric monitor was compared to the auscultatory mercury manometer blood pressure measurement in apparently healthy school age children. METHODS: A device able to perform 3 simultaneous readings are used: one reading by the monitor and the others by two "blind" observers. We studied 72 school age children with the following characteristics: mean age 9.5 (6.1-16.1) and 39 males (54.2%). RESULTS: The difference for the systolic and diastolic blood pressure obtained by the monitor was in average + 6.2 mmHg and + 10.0 mmHg, respectively, when compared to the observer's readings. There was neither a good correlation nor a good agreement between the two observers and the monitor in the blood pressure determination. CONCLUSIONS: We concluded that the substitution of the standard auscultatory method for the non-invasive oscillometric method to measure blood pressure in school age children can not be generally recommended.

  13. [Achievement of the noninvasive measurement for human blood glucose with NIR diffusion reflectance spectrum method].

    Science.gov (United States)

    Zhang, Hong-yan; Ding, Dong; Song, Li-qiang; Gu, Lin-na; Yang, Peng; Tang, Yu-guo

    2005-06-01

    The noninvasive measurement of human blood glucose was achieved with NIR diffusion reflectance spectrum method. The thumb fingertip NIR diffusion reflectance spectra of six different age healthy volunteers were collected using Nexus-870 and its NIR fiber port smart accessory. The test was implemented with changing the blood glucose concentration for the limosis and satiation of every volunteer. The calibration model was set up using PLS method with the smoothing, baseline correction and first derivatives pretreatment spectrum in the 7500-8500 cm(-1) region for single volunteer, the same age combination and that of different age. When the spectrum was obtained, the actual blood glucose value of every spectrun sample was demarcated using ultraviolet spectrophotometer. The correlation between the calibration value and true value for single volunteer is better than that for the combination of volunteers, the correlative coefficients are all over 0.90471, RMSECs are all less than 0.171.

  14. Cerebral blood flow and autoregulation: current measurement techniques and prospects for noninvasive optical methods.

    Science.gov (United States)

    Fantini, Sergio; Sassaroli, Angelo; Tgavalekos, Kristen T; Kornbluth, Joshua

    2016-07-01

    Cerebral blood flow (CBF) and cerebral autoregulation (CA) are critically important to maintain proper brain perfusion and supply the brain with the necessary oxygen and energy substrates. Adequate brain perfusion is required to support normal brain function, to achieve successful aging, and to navigate acute and chronic medical conditions. We review the general principles of CBF measurements and the current techniques to measure CBF based on direct intravascular measurements, nuclear medicine, X-ray imaging, magnetic resonance imaging, ultrasound techniques, thermal diffusion, and optical methods. We also review techniques for arterial blood pressure measurements as well as theoretical and experimental methods for the assessment of CA, including recent approaches based on optical techniques. The assessment of cerebral perfusion in the clinical practice is also presented. The comprehensive description of principles, methods, and clinical requirements of CBF and CA measurements highlights the potentially important role that noninvasive optical methods can play in the assessment of neurovascular health. In fact, optical techniques have the ability to provide a noninvasive, quantitative, and continuous monitor of CBF and autoregulation.

  15. A study on measurement of the regional cerebral blood flow using autoradiographic method in moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Tomohiro; Kiya, Katsuzo; Yuki, Kiyoshi; Kawamoto, Hitoshi; Mizoue, Tatsuya; Kiura, Yoshihiro; Uozumi, Tohru [Hiroshima Prefectural Hospital (Japan); Ikawa, Fusao

    1997-11-01

    Development of Autoradiographic method (ARG) has provided measurement of cerebral blood flow in moyamoya disease. We evaluate a cerebral vasodilatory capacity (CVC) for moyamoya disease using ARG method. We used 5 patients with moyamoya disease as a candidate for measurement of the cerebral blood flow (CBF) who admitted to Hiroshima Prefectural Hospital during the past one year. There were 3 patients in an adult age and 2 patients in a young age. We tried to measure the regional CBF (rCBF) using ARG method which was a easy way to estimate the rCBF on SPECT. The CVC was calculated from the difference of the rCBF between resting SPECT and Diamox-loading SPECT. Results were as follows; Reactivity of cerebral vessels to CO{sub 2} loading and CVC weakened in moyamoya disease. The rCBF and CVC in the territories of anterior and middle cerebral arteries reduced in comparison with those in the area supplied by the posterior cerebral artery. The CVC at the treated side with surgical reconstruction recovered somewhat in an adult type. From these results, measurement of CBF using ARG method seems to be useful for evaluation of the CVC in moyamoya disease. (author)

  16. [The analysis for improving the SNR of blood components noninvasive measurement with DS method].

    Science.gov (United States)

    Li, Gang; Wang, Hui-quan; Zhao, Zhe; Lin, Ling; Zhang, Bao-ju; Wu, Xiao-rong

    2012-08-01

    In order to increase the accuracy of blood components measurement and enhance the stability of prediction model, the quantitative signal-noise-ratio (SNR) analysis of measuring instruments based on dynamic spectrum (DS) and preprocessing method was conducted. The SNR of DS is increased after adding boxcar integrator, decreasing wavelength revolution, balancing the DS's SNR and excluding gross errors in preprocessing according to experiment results. Two volunteers were tested continuously for many times using the DS data acquiring system. The correlation coefficients of the each volunteer's DS data was increased from 0.934 and 0.953 to 0.991 and 0.987, respectively. Moreover, the gap between the correlation coefficient of the same volunteer's DS and different volunteers' DS is increased too, which shows that the SNR can be improved by these methods. The quantitative SNR analysis can guide the way of choosing preprocessing method efficiently, which will create the condition for clinical application of the blood components noninvasive measurement.

  17. Assessment of skin flaps using optically based methods for measuring blood flow and oxygenation.

    Science.gov (United States)

    Payette, Jeri R; Kohlenberg, Elicia; Leonardi, Lorenzo; Pabbies, Arone; Kerr, Paul; Liu, Kan-Zhi; Sowa, Michael G

    2005-02-01

    The objective of this study was to compare two noninvasive techniques, laser Doppler and optical spectroscopy, for monitoring hemodynamic changes in skin flaps. Animal models for assessing these changes in microvascular free flaps and pedicle flaps were investigated. A 2 x 3-cm free flap model based on the epigastric vein-artery pair and a reversed MacFarlane 3 x 10-cm pedicle flap model were used in this study. Animals were divided into four groups, with groups 1 (n = 6) and 2 (n = 4) undergoing epigastric free flap surgery and groups 3 (n = 3) and 4 (n = 10) undergoing pedicle flap surgery. Groups 1 and 4 served as controls for each of the flap models. Groups 2 and 3 served as ischemia-reperfusion models. Optical spectroscopy provides a measure of hemoglobin oxygen saturation and blood volume, and the laser Doppler method measures blood flow. Optical spectroscopy proved to be consistently more reliable in detecting problems with arterial in flow compared with laser Doppler assessments. When spectroscopy was used in an imaging configuration, oxygen saturation images of the entire flap were generated, thus creating a visual picture of global flap health. In both single-point and imaging modes the technique was sensitive to vessel manipulation, with the immediate post operative images providing an accurate prediction of eventual outcome. This series of skin flap studies suggests a potential role for optical spectroscopy and spectroscopic imaging in the clinical assessment of skin flaps.

  18. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  19. New method for measuring myocardial blood flow by high resolution scintigraphy in the excised dog heart.

    Science.gov (United States)

    Hung, C Y; Burow, R D; Scherlag, B J; Basmadjian, G P; Lazzara, R

    1986-10-01

    The standard method for measuring myocardial blood flow (MBF) with radioactive microspheres requires processing of selected tissue samples usually from the excised heart, and consequent loss of exact relation to myocardial morphology. A computer-based image processing method was developed by using [99mTc]microspheres (mean particle size 20 microns) for quantitative analysis of MBF in 25 dogs. A computer-controlled gamma camera was used to obtain the images of radioactive microsphere distribution in transaxial slices of the ex vivo heart. Any portion of these slice images could be quantitated by using a computer program based on modification of the formula for determining MBF by the standard microsphere method. Regional myocardial perfusion calculated by this technique correlated well with values obtained with reference microspheres (r = 0.96) over a broad range of MBF. The results show that our new method, accurately and with high resolution, delineated zones of differing MBF and confirmed the increase of MBF in surviving myocardium with healing.

  20. New method for measuring myocardial blood flow by high resolution scintigraphy in the excised dog heart

    Energy Technology Data Exchange (ETDEWEB)

    Hung, C.Y.; Burow, R.D.; Scherlag, B.J.; Basmadjian, G.P.; Lazzara, R.

    1986-10-01

    The standard method for measuring myocardial blood flow (MBF) with radioactive microspheres requires processing of selected tissue samples usually from the excised heart, and consequent loss of exact relation to myocardial morphology. A computer-based image processing method was developed by using (99mTc)microspheres (mean particle size 20 microns) for quantitative analysis of MBF in 25 dogs. A computer-controlled gamma camera was used to obtain the images of radioactive microsphere distribution in transaxial slices of the ex vivo heart. Any portion of these slice images could be quantitated by using a computer program based on modification of the formula for determining MBF by the standard microsphere method. Regional myocardial perfusion calculated by this technique correlated well with values obtained with reference microspheres (r = 0.96) over a broad range of MBF. The results show that our new method, accurately and with high resolution, delineated zones of differing MBF and confirmed the increase of MBF in surviving myocardium with healing.

  1. [Blood flow measurement in arteriovenous fistula. Comparison of 2 ultrasonic methods, direct and indirect by compression of the fistula].

    Science.gov (United States)

    Deklunder, G; Goullard, L; Lecroart, J L; Foulard, M; Houdas, Y

    1990-05-19

    Measuring blood flow in arteriovenous fistulae in patients under chronic dialysis is of interest to evaluate the repercussions of the fistula on the heart. The apparently simplest method is direct measurement of the mean blood flow velocity by the pulsed doppler technique and ot the cross-section area by ultrasonography, the product of these two values being the blood flow rate. Another method has been proposed, which consists of measuring the cardiac output before and after compression of the fistula, the difference between the two values being supposed to represent the blood flow rate in the fistula. A comparative study of these two methods was conducted in 17 patients aged from 2 to 21 years (mean: 14 years). The direct method gave a figure of 475 ml.min-1.m-2 (SD = 240), while the figure obtained with the indirect method was 471 ml.min-1.m-2 (SD = 227); the difference was statistically not significant. In terms of concept, however, the indirect method is open to much more severe criticism than the direct method, and whenever possible the latter should be preferred when measuring blood flow in arteriovenous fistulae.

  2. Development of a method for measuring blood coagulation using superparamagnetic iron oxide nanoparticles and an alternating magnetic field

    CERN Document Server

    Murase, Kenya

    2016-01-01

    We developed a method for measuring blood coagulation using superparamagnetic iron oxide nanoparticles (SPIONs) and an alternating magnetic field (AMF). The 3rd and 5th harmonic signals from SPIONs mixed with blood induced by AMF were detected using a gradiometer coil. Blood coagulation was induced artificially by adding CaCl2 solution to whole blood of sheep at various temperatures and hematocrits. We calculated the coagulation rate (k) and normalized signal intensity at infinite time (Sinf) by fitting the time course of the normalized 3rd harmonic signal to S(t)=(1-Sinf)exp(-kt)+Sinf. The k values increased significantly with increasing temperature and decreased significantly with increasing hematocrit. The Sinf values decreased significantly with increasing temperature and tended to increase with increasing hematocrit. Blood anticoagulation was induced by adding heparin to the whole blood sampled from mice. There were significant differences in both the 3rd and 5th harmonic signals between groups with and ...

  3. Blood pressure measurement in children: which method? which is the gold standard.

    Science.gov (United States)

    Vidal, Enrico; Murer, Luisa; Matteucci, Maria Chiara

    2013-01-01

    The burden of hypertension has become increasingly prevalent in children. Hypertension that begins in childhood can carry on into adulthood, therefore early detection, accurate diagnosis and effective therapy of high blood pressure may improve long-term outcomes of children and adolescents. As far as pediatric hypertension is concerned, doubts still persist about the right instruments, modalities and standards of reference that should be used in routine practice. Due to the dynamic process of growth and development, many physiological parameters undergo intensive change with age. Therefore, in children, the definition of hypertension can not rely on a single blood pressure level but should be based on age- and height-specific percentiles. In this review, we introduce the nephrologist to the correct definition of high blood pressure in children. Moreover, we specifically address the main characteristics of different modalities for blood pressure measurement in children, focusing on practical aspects. The latest international guidelines and appropriate standards of reference for office, ambulatory and home blood pressure data collection are presented. As clinicians are being faced with a greater number of children with hypertension, they should be aware of these peculiarities.

  4. Comparison of the effects of two teaching methods on the nursing students’ performance in measurement of blood pressure

    Science.gov (United States)

    Eghbalibabadi, Maryam; Ashouri, Elaheh

    2014-01-01

    Background: New teaching methods are essential in the promotion of competence in nursing students. Measuring blood pressure, which is one of the most essential skills, is the foundation of nursing care and clinical decision-making, and students should be trained to master this skill. This study aimed to determine the impact of two teaching methods on students’ performance in blood pressure measurements. Materials and Methods: In this semi-experimental study, 36 first-term nursing students from Isfahan University of Medical Sciences, Iran, were divided into six groups of six people each. The type of training for each group was determined by random draw. Blood pressure measurement training was given to three groups on a simulator and to the other three groups on human samples. Pre- and post-test evaluation of knowledge of the methods of measuring blood pressure was conducted using a researcher-made checklist and by observation of the students’ actions. The knowledge and skill scores were compared using paired and independent t-tests. Results: The mean performance scores of students in simulator (19.14 ± 1.60) and human (19.64 ± 1.08) groups were not significantly different. In both methods, there was no significant difference between systolic and diastolic blood pressures measured by students and by teachers (standard). Mean knowledge scores of both groups increased significantly after training compared to before training. Conclusions: According to the results of the study, the two training methods (on human subjects and simulator) provide the students with the necessary ability to measure the systolic and diastolic blood pressures correctly. Therefore, to enrich the educational program of nursing students, using simulators is recommended as an effective teaching strategy to facilitate learning and for the development of students’ knowledge. PMID:25183979

  5. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry......, the oscillometry showed a positive predictive value of 47%. The presence of PAD was significantly correlated to exercise related leg pain, a diagnosis of hypertension and smoking, whereas no correlation could be found with a diagnosis of heart disease, stroke, or with the presence of diabetes. The prevalence...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  6. ACCURACY OF OSCILLOMETRIC (PETMAP™ AND DOPPLER METHODS TO INDIRECT MEASUREMENT OF BLOOD PRESSURE IN LAMBS

    Directory of Open Access Journals (Sweden)

    Carla Maria Vela Ulian

    2016-10-01

    Full Text Available Neonatal physiology has peculiarities inherent to the age group. The objective of this study was to monitor the systemic arterial pressure in lambs during neonatal period. We used 20 Ile de France lambs, from birth and at 7, 14, 21, 28 and 35 days of life. The following parameters were analyzed: heart rate (HR, systolic (SBP, diastolic (DBP, and average blood pressure (ABP by oscillometric method petMAP™, and SBP with Doppler. Invasive pressure validated indirect methods with the average 101.52 ± 12.04 mmHg. The averages with petMAP™ were as follows: HR (156.38 ± 37.46 bpm; DBP (63.80 ± 11.14 mmHg; ABP (81.58 ± 11.83 mmHg; SBP (112.48 ± 15.68 mmHg and SBP by Dobler (90.27 ± 12.11 mmHg. There was significant difference in HR and blood pressure among the moments. Indirect methods differ between each other in 12.30 mmHg (overestimation   of 11%. Comparing with the invasive methods, both overestimated values of 4% and 16% in   PAS, respectively, for Doppler and petMAP™. The results showed that the Doppler method has established a good relationship with the invasive one being useful for gauging the SBP. The oscillometric method requires larger studies to be used in small ruminants. Keywords: Doppler; lamb; neonatal period; oscillometric; systemic blood pressure.

  7. Localized T2 measurements using an OSIRIS-CPMG method. Application to measurements of blood oxygenation and transverse relaxation free of diffusion effect.

    Science.gov (United States)

    Girard, F; Poulet, P; Namer, I J; Steibel, J; Chambron, J

    1994-12-01

    This work presents a new method allowing localized T2 measurements, based upon the OSIRIS scheme. A train of 180 degrees pulses is applied after the OSIRIS preparation cycle, recording directly the transverse magnetization decay. The method was verified for two nuclei, 1H and 19F, with phantoms and in vivo on rats. The accuracy of the T2 values is discussed, as well as possible applications of the OSIRIS-CPMG method to proton transverse spin relaxation measurements, free of diffusion effects, and to non-invasive in vivo blood oxygenation measurements, through the use of an emulsion of perfluorooctylbromide, a blood substitute containing fluorine.

  8. Measurement of blood-brain barrier permeability using dynamic Gd-DTPA scanning--a comparison of methods

    DEFF Research Database (Denmark)

    Larsson, H B; Tofts, P S

    1992-01-01

    Two recently published methods of blood-brain barrier permeability measurement using Gd-DTPA scanning are compared by authors representing each group. The physiological models are reconciled. Results from both groups agree. These show that the transfer constant (the permeability surface area prod...

  9. Suitable image parameters and analytical method for quantitatively measuring cerebral blood flow volume with phase-contrast magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Handa H

    1999-02-01

    Full Text Available The aim of this study was to determine suitable image parameters and an analytical method for phase-contrast magnetic resonance imaging (PC-MRI as a means of measuring cerebral blood flow volume. This was done by constructing an experimental model and applying the results to a clinical application. The experimental model was constructed from the aorta of a bull and circulating isotonic saline. The image parameters of PC-MRI (repetition time, flip angle, matrix, velocity rate encoding, and the use of square pixels were studied with percent flow volume (the ratio of actual flow volume to measured flow volume. The most suitable image parameters for accurate blood flow measurement were as follows: repetition time, 50 msec; flip angle, 20 degrees; and a 512 x 256 matrix without square pixels. Furthermore, velocity rate encoding should be set ranging from the maximum flow velocity in the vessel to five times this value. The correction in measuring blood flow was done with the intensity of the region of interest established in the background. With these parameters for PC-MRI, percent flow volume was greater than 90%. Using the image parameters for PC-MRI and the analytical method described above, we evaluated cerebral blood flow volume in 12 patients with occlusive disease of the major cervical arteries. The results were compared with conventional xenon computed tomography. The values found with both methods showed good correlation. Thus, we concluded that PC-MRI was a noninvasive method for evaluating cerebral blood flow in patients with occlusive disease of the major cervical arteries.

  10. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required.

  11. Effects of Different Blood Sampling Methods on Value of Blood Glucose Measured by Rapid Blood Glucose Meter%采血方法对快速血糖测定仪测量值的影响

    Institute of Scientific and Technical Information of China (English)

    赵东荣

    2015-01-01

    目的:探讨不同采血方法对快速血糖测定仪测量值的影响。方法通过对60例糖尿病患者采用3种不同的采血方法,即自然流出法、热水热敷按摩法和手指挤血法,进行末梢血糖浓度的快速测定,同时利用大型生化分析仪测定其静脉血血糖浓度。结果自然流出法测定血糖值和静脉血糖值比较差异无统计学意义(P>0.05),热水热敷按摩和手指挤血法测定血糖值均显著低于静脉血糖值,差异均有统计学意义(P<0.05)。结论临床上使用快速血糖仪检测血糖值时,为保证结果的准确性,宜采用自然流出法采取末梢血。%ObjectiveTo assess the inlfuence of different methods of blood sampling on the results tested by rapid blood glucose meter.Methods Blood glucose of 60 patients with diabetes were tested by rapid blood glucose meter through 3 different methods of blood sampling, and compared with the value of blood glucose measured by taking glucose oxidation enzyme from venous blood.Results There was no statistical signiifcance in value of blood glucose between natural effusion group and venous blood (P>0.05). The values of blood glucose in hot water massage group and finger squeezing group were remarkably lower than those in venous blood group (P<0.05).Conclusion The natural blood out flow of fingers is the better way when value of blood glucose measured by rapid blood glucose meter in clinic.

  12. Reproducibility of regional cerebral blood flow measurement at rest with autoradiography method using {sup 123}I-IMP and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Kyoko; Murata, Hajime; Maruno, Hirotaka; Mori, Kazuaki; Tsuchida, Shoichi [Toranomon Hospital, Tokyo (Japan)

    1997-05-01

    Reproducibility of regional cerebral blood flow (rCBF) values obtained by the autoradiography (ARG) method with one SPECT scan and one point arterial blood sampling at 10 min after {sup 123}I-N-isopropyl-p-iodoamphetamine (IMP) infusion was evaluated. The variation in the cross calibration factor between SPECT counts and well-type scintillation counts remained 2.2% for 13 months. The error in rCBF by sampling time difference was less than 3% when sampling time was within 10 min{+-}30 sec after infusion. There was a favorable correlation between the rCBF values in two separate resting scans measured by the ARG method in 10 patients (r=0.907). And the mean ratio of rCBF values by the second study to those by the first study in the cerebellum and cerebral lobes in 10 patients was 0.989{+-}0.056 (mean{+-}SD). There was no significant difference in rCBF values between two separate studies. Reproducibility of rCBF with the ARG method was proved to be good. The ARG method was thought to be useful for the assessment of treatment effects and clinical courses. (author)

  13. Multivariate regression and discreminant calibration models for a novel optical non-invasive blood glucose measurement method named pulse glucometry.

    Science.gov (United States)

    Yamakoshi, Yasuhiro; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tamura, Toshiyo; Yamakoshi, Ken-ichi

    2009-01-01

    A novel optical non-invasive in vivo blood glucose concentration (BGL) measurement technique, named "Pulse Glucometry", was combined with a kernel method; support vector machines. The total transmitted radiation intensity (I(lambda)) and the cardiac-related pulsatile changes superimposed on I(lambda) in human adult fingertips were measured over the wavelength range from 900 to 1700 nm using a very fast spectrophotometer, obtaining a differential optical density (DeltaOD(lambda)) related to the blood component in the finger tissues. Subsequently, a calibration model using paired data of a family of DeltaOD(lambda)s and the corresponding known BGLs was constructed with support vector machines (SVMs) regression instead of using calibration by a conventional primary component regression (PCR) and partial least squares regression (PLS). Secondly, SVM method was applied to make a nonlinear discriminant calibration model for "Pulse glucometry." Our results show that the regression calibration model based on the support vector machines can provide a good regression for the 101 paired data, in which the BGLs ranged from 89.0-219 mg/dl (4.94-12.2 mmol/l). The resultant regression was evaluated by the Clarke error grid analysis and all data points fell within the clinically acceptable regions (region A: 93%, region B: 7%). The discriminant calibration model using SVMs also provided a good result for classification (accuracy rate 84% in the best case).

  14. A Simple Flow Cytometric Method to Measure Glucose Uptake and Glucose Transporter Expression for Monocyte Subpopulations in Whole Blood.

    Science.gov (United States)

    Palmer, Clovis S; Anzinger, Joshua J; Butterfield, Tiffany R; McCune, Joseph M; Crowe, Suzanne M

    2016-08-12

    Monocytes are innate immune cells that can be activated by pathogens and inflammation associated with certain chronic inflammatory diseases. Activation of monocytes induces effector functions and a concomitant shift from oxidative to glycolytic metabolism that is accompanied by increased glucose transporter expression. This increased glycolytic metabolism is also observed for trained immunity of monocytes, a form of innate immunological memory. Although in vitro protocols examining glucose transporter expression and glucose uptake by monocytes have been described, none have been examined by multi-parametric flow cytometry in whole blood. We describe a multi-parametric flow cytometric protocol for the measurement of fluorescent glucose analog 2-NBDG uptake in whole blood by total monocytes and the classical (CD14(++)CD16(-)), intermediate (CD14(++)CD16(+)) and non-classical (CD14(+)CD16(++)) monocyte subpopulations. This method can be used to examine glucose transporter expression and glucose uptake for total monocytes and monocyte subpopulations during homeostasis and inflammatory disease, and can be easily modified to examine glucose uptake for other leukocytes and leukocyte subpopulations within blood.

  15. Comparison of two flow-based imaging methods to measure individual red blood cell area and volume.

    Science.gov (United States)

    Tomaiuolo, Giovanna; Rossi, Domenico; Caserta, Sergio; Cesarelli, Mario; Guido, Stefano

    2012-12-01

    The red blood cells (RBCs) population is characterized by a high heterogeneity in membrane area, cellular volume, and mechanical properties, mainly due to the variety of mechanical and chemical stresses that a red cell undergoes in its entire life span. Here, we provide the first simultaneous area and volume measurements of RBCs flowing in microcapillaries, by using high-speed video microscopy imaging and quantitative data processing based on image analysis techniques. Both confined and unbounded flow conditions (depending on the relative size of RBCs and microcapillary diameter) are investigated. The results are compared with micropipette experiments from the literature and data from Coulter counter routine clinical blood tests. Good agreement is found for RBC volume, especially in the case of confined flow conditions. Surface area measurements, which are lacking in the routine clinical test, are of special interest being a potential diagnostic parameter of altered cell deformability and aggregability. Overall, our results provide a novel flow methodology suitable for high-throughput measurements of RBC geometrical parameters, allowing one to overcome the limits of classical static methods, such as micropipette aspiration, which are not suitable for handling a large number of cells.

  16. Focal cerebral ischemia measured by the intra-arterial 133xenon method. Limitations of 2-dimensional blood flow measurements

    DEFF Research Database (Denmark)

    Skyhøj Olsen, T; Larsen, B; Bech Skriver, E;

    1981-01-01

    of 133 xenon (rCBF), 2) the initial distribution of isotope during the first 5 sec and 3) the cumulated counts recorded during 15 min. Compton scatter and the "look through phenomenon" were responsible for the majority of counts recorded from the infarcted areas and the blood flow recorded was found...... to be grossly overestimated and much more influenced by the blood flow in the surroundings than in the ischemic area itself. However, using the 3 approaches, infarcted areas were always disclosed by our equipment. It is concluded that 2-dimensional isotope technique is not reliable for quantifying focal...... with infarcts involving cortical surface structures were included in the study. Eleven such patients were found among 43 consecutive patients with completed stroke, all investigated with CT-scan. The blood supply to the infarcted areas was evaluated using 3 different approaches: 1) The first minute washout...

  17. Focal cerebral ischemia measured by the intra-arterial 133xenon method. Limitations of 2-dimensional blood flow measurements

    DEFF Research Database (Denmark)

    Skyhøj Olsen, T; Larsen, B; Bech Skriver, E;

    1981-01-01

    with infarcts involving cortical surface structures were included in the study. Eleven such patients were found among 43 consecutive patients with completed stroke, all investigated with CT-scan. The blood supply to the infarcted areas was evaluated using 3 different approaches: 1) The first minute washout...... of 133 xenon (rCBF), 2) the initial distribution of isotope during the first 5 sec and 3) the cumulated counts recorded during 15 min. Compton scatter and the "look through phenomenon" were responsible for the majority of counts recorded from the infarcted areas and the blood flow recorded was found...... to be grossly overestimated and much more influenced by the blood flow in the surroundings than in the ischemic area itself. However, using the 3 approaches, infarcted areas were always disclosed by our equipment. It is concluded that 2-dimensional isotope technique is not reliable for quantifying focal...

  18. Methodical aspects of blood coagulation measurements in birds applying commercial reagents--a pilot study.

    Science.gov (United States)

    Guddorf, Vanessa; Kummerfeld, Norbert; Mischke, Reinhard

    2014-01-01

    The aim of this study was to examine the suitability of commercially available reagents for measurements of coagulation parameters in citrated plasma from birds. Therefore, plasma samples of 17 healthy donor birds of different species were used to determine prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT) applying various commercial reagents which are routinely used in coagulation diagnostics in humans and mammals. A PT reagent based on human placental thromboplastin yielded not only shorter clotting times than a reagent containing recombinant human tissue factor (median 49 vs. 84 s), but also showed a minor range of distribution of values (43-55 s vs. 30-147 s, minimum-maximum, n = 5 turkeys). An aPTT reagent containing kaolin and phospholipids of animal origin delivered the shortest clotting times and the lowest range of variation in comparison to three other reagents of different composition. However, even when this reagent was used, aPTTs were partially extremely long (> 200 s). Thrombin time was 38 s (28-57 s, n = 5 chicken) when measured with bovine thrombin at a final concentration of 2 IU thrombin/ ml. Coefficients of variation for within-run precision analysis (20 repetitions) of PT was 8.0% and 4.7% for aPTT measurements using selected reagents of mammalian origin. In conclusion, of the commercially available reagents tested, a PT reagent based on human placental thromboplastin and an aPTT reagent including rabbit brain phospholipid and kaolin, show some promise for potential use in birds.

  19. A novel method of combining blood oxygenation and blood flow sensitive magnetic resonance imaging techniques to measure the cerebral blood flow and oxygen metabolism responses to an unknown neural stimulus.

    Directory of Open Access Journals (Sweden)

    Aaron B Simon

    Full Text Available Simultaneous implementation of magnetic resonance imaging methods for Arterial Spin Labeling (ASL and Blood Oxygenation Level Dependent (BOLD imaging makes it possible to quantitatively measure the changes in cerebral blood flow (CBF and cerebral oxygen metabolism (CMRO(2 that occur in response to neural stimuli. To date, however, the range of neural stimuli amenable to quantitative analysis is limited to those that may be presented in a simple block or event related design such that measurements may be repeated and averaged to improve precision. Here we examined the feasibility of using the relationship between cerebral blood flow and the BOLD signal to improve dynamic estimates of blood flow fluctuations as well as to estimate metabolic-hemodynamic coupling under conditions where a stimulus pattern is unknown. We found that by combining the information contained in simultaneously acquired BOLD and ASL signals through a method we term BOLD Constrained Perfusion (BCP estimation, we could significantly improve the precision of our estimates of the hemodynamic response to a visual stimulus and, under the conditions of a calibrated BOLD experiment, accurately determine the ratio of the oxygen metabolic response to the hemodynamic response. Importantly we were able to accomplish this without utilizing a priori knowledge of the temporal nature of the neural stimulus, suggesting that BOLD Constrained Perfusion estimation may make it feasible to quantitatively study the cerebral metabolic and hemodynamic responses to more natural stimuli that cannot be easily repeated or averaged.

  20. A novel method of combining blood oxygenation and blood flow sensitive magnetic resonance imaging techniques to measure the cerebral blood flow and oxygen metabolism responses to an unknown neural stimulus.

    Science.gov (United States)

    Simon, Aaron B; Griffeth, Valerie E M; Wong, Eric C; Buxton, Richard B

    2013-01-01

    Simultaneous implementation of magnetic resonance imaging methods for Arterial Spin Labeling (ASL) and Blood Oxygenation Level Dependent (BOLD) imaging makes it possible to quantitatively measure the changes in cerebral blood flow (CBF) and cerebral oxygen metabolism (CMRO(2)) that occur in response to neural stimuli. To date, however, the range of neural stimuli amenable to quantitative analysis is limited to those that may be presented in a simple block or event related design such that measurements may be repeated and averaged to improve precision. Here we examined the feasibility of using the relationship between cerebral blood flow and the BOLD signal to improve dynamic estimates of blood flow fluctuations as well as to estimate metabolic-hemodynamic coupling under conditions where a stimulus pattern is unknown. We found that by combining the information contained in simultaneously acquired BOLD and ASL signals through a method we term BOLD Constrained Perfusion (BCP) estimation, we could significantly improve the precision of our estimates of the hemodynamic response to a visual stimulus and, under the conditions of a calibrated BOLD experiment, accurately determine the ratio of the oxygen metabolic response to the hemodynamic response. Importantly we were able to accomplish this without utilizing a priori knowledge of the temporal nature of the neural stimulus, suggesting that BOLD Constrained Perfusion estimation may make it feasible to quantitatively study the cerebral metabolic and hemodynamic responses to more natural stimuli that cannot be easily repeated or averaged.

  1. Quantitative Cerebral Blood Flow Measurements Using MRI

    OpenAIRE

    Muir, Eric R; Watts, Lora Talley; Tiwari, Yash Vardhan; Bresnen, Andrew; Timothy Q Duong

    2014-01-01

    Magnetic resonance imaging utilized as a quantitative and noninvasive method to image cerebral blood flow. The two most common techniques used to detect cerebral blood flow are dynamic susceptibility contrast (DSC) perfusion MRI and arterial spin labeling perfusion MRI. Herein we describe the use of these two techniques to measure cerebral blood flow in rodents, including methods, analysis, and important considerations when utilizing these techniques.

  2. Working meeting on blood pressure measurement: suggestions for measuring blood pressure to use in populations surveys.

    Science.gov (United States)

    2003-11-01

    As part of the Pan American Hypertension Initiative (PAHI), the Pan American Health Organization and the National Heart, Lung, and Blood Institute of the National Institutes of Health of the United States of America conducted a working meeting to discuss blood pressure (BP) measurement methods used in various hypertension prevalence surveys and clinical trials, with the objective of developing a BP measurement protocol for use in hypertension prevalence surveys in the Americas. No such common protocol has existed in the Americas, so it has been difficult to compare hypertension prevention and intervention strategies. This piece describes a proposed standard method for measuring blood pressure for use in population surveys in the Region of the Americas. The piece covers: considerations for developing a common blood pressure measurement protocol, critical issues in measuring blood pressure in national surveys, minimum procedures for blood pressure measurement during surveillance, and quality assessment of blood pressure.

  3. Pancreatic islet blood flow and its measurement.

    Science.gov (United States)

    Jansson, Leif; Barbu, Andreea; Bodin, Birgitta; Drott, Carl Johan; Espes, Daniel; Gao, Xiang; Grapensparr, Liza; Källskog, Örjan; Lau, Joey; Liljebäck, Hanna; Palm, Fredrik; Quach, My; Sandberg, Monica; Strömberg, Victoria; Ullsten, Sara; Carlsson, Per-Ola

    2016-05-01

    Pancreatic islets are richly vascularized, and islet blood vessels are uniquely adapted to maintain and support the internal milieu of the islets favoring normal endocrine function. Islet blood flow is normally very high compared with that to the exocrine pancreas and is autonomously regulated through complex interactions between the nervous system, metabolites from insulin secreting β-cells, endothelium-derived mediators, and hormones. The islet blood flow is normally coupled to the needs for insulin release and is usually disturbed during glucose intolerance and overt diabetes. The present review provides a brief background on islet vascular function and especially focuses on available techniques to measure islet blood perfusion. The gold standard for islet blood flow measurements in experimental animals is the microsphere technique, and its advantages and disadvantages will be discussed. In humans there are still no methods to measure islet blood flow selectively, but new developments in radiological techniques hold great hopes for the future.

  4. Patient-specific errors in agreement between International Normalized Ratios measured by a whole blood coagulometer and by a routine plasma-based method.

    Science.gov (United States)

    Attermann, Jørn; Andersen, Niels T; Korsgaard, Helle; Maegaard, Marianne; Hasenkam, J Michael

    2004-04-01

    We applied a new statistical method to improve comparisons between systems measuring prothrombin time (PT) by splitting disagreement into systematic errors, which can be eliminated, and random errors, which can not. We found that the disagreement between International Normalized Ratio (INR) measurements based on plasma and whole blood was significantly patient-dependent.

  5. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  6. Transcutaneous measurement of volume blood flow

    Science.gov (United States)

    Daigle, R. E.; Mcleod, F. D.; Miller, C. W.; Histand, M. B.; Wells, M. K.

    1974-01-01

    Blood flow velocity measurements, using Doppler velocimeter, are described. The ability to measure blood velocity using ultrasound is derived from the Doppler effect; the change in frequency which occurs when sound is reflected or transmitted from a moving target. When ultrasound of the appropriate frequency is transmitted through a moving blood stream, the blood cells act as point scatterers of ultrasonic energy. If this scattered ultrasonic energy is detected, it is found to be shifted in frequency according to the velocity of the blood cells, nu, the frequency of the incident sound, f sub o, the speed of sound in the medium, c, and the angle between the sound beam and the velocity vector, o. The relation describing this effect is known as the Doppler equation. Delta f = 2 f sub o x nu x cos alpha/c. The theoretical and experimental methods are evaluated.

  7. Blood Glucose Measurement Using Bioimpedance Technique

    OpenAIRE

    2014-01-01

    Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner ...

  8. Tomographic measurement of cerebral blood flow by the /sup 68/Ga-labelled-microsphere and continuous-C/sup 15/O/sub 2/-inhalation methods

    Energy Technology Data Exchange (ETDEWEB)

    Steinling, M.; Baron, J.C.; Maziere, B.; Loc' h, C.; Lasjaunias, P.; Canabis, E.A.; Guillon, B.

    1985-05-01

    The measurement of cerebral blood flow (CBF) by continuous C/sup 15/O/sub 2/ inhalation has only been validated previously by indirect experimental protocols. In the present study using baboons, these measurements were compared directly with those obtained by injection of /sup 68/Ga-labelled serum-albumin microspheres in the left cardiac ventricle. Using a modified labelling technique, no elution of /sup 68/Ga occurred in vivo. Both methods provided similar regional CBF values, which could be described by a significant linear correlation (CBFsub(CO2) = 0.82 CBFsub(microspheres)+5.7; P < 0.001). The validity of the labelled-microsphere-injection method was verified. The feasibility of stable in vivo labelling of /sup 68/Ga to serum-albumin microspheres provides a reference method for organ blood-flow measurements using positron-emission tomography.

  9. Tomographic measurement of cerebral blood flow by the /sup 68/Ga-labelled-microsphere and continuous-C/sup 15/O/sub 2/-inhalation methods

    Energy Technology Data Exchange (ETDEWEB)

    Steinling, M.; Baron, J.C.; Maziere, B.; Loc' h, C.; Lasjaunias, P.; Canabis, E.A.; Guillon, B.

    1985-07-01

    The measurement of cerebral blood flow (CBF) by continuous C/sup 15/O/sub 2/ inhalation has only been validated previously by indirect experimental protocols. In the present study using baboons, these measurements were compared directly with those obtained by injection of /sup 68/Ga-labelled serum-albumin microspheres in the left cardiac ventricle. Using a modified labelling technique, no elution of /sup 68/Ga occurred in vivo. Both methods provided similar regional CBF values, which could be described by a significant linear correlation (CBFsub(CO2)=0.82 CBFsub(microspheres)+5.7; P < 0.001). The validity of the labelled-microsphere-injection method was verified. The feasibility of stable in vivo labelling of /sup 68/Ga to serum-albumin microspheres provides a reference method for organ blood-flow measurements using positron-emission tomography.

  10. Non-Invasive Optical Blood Glucose Measurement

    Directory of Open Access Journals (Sweden)

    Megha C.Pande

    2013-07-01

    Full Text Available The method for noninvasively blood glucose monitoring system is discussed in this paper. Lot of research work has been done in developing the device which is completely noninvasive to avoid the pros & cons because of frequent pricking. In this paper we are trying to analyze the noninvasive blood glucose measurement study in the near infrared region which is the most suitable region for blood glucose measurement. For this purpose we use a technique which is similar to pulseoximetry based on near infrared spectrometry .An infrared light of particular wavelength is passed through fingertip containing an arterial pulse component are derived,thus minimizing influences of basal components such as resting blood volume,skin, muscle and bone.

  11. Effect of sumatriptan on cerebral blood flow during migraine headache. Measurement by sequential SPECT used {sup 99m}Tc-ECD background subtraction method

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Takashi; Torihara, Yoshito; Tsuneyoshi, Noritaka; Ikeda, Yoshitomo [Miyazaki Social Insurance Hospital (Japan)

    2001-07-01

    The present study was designed to examine the effect of sumatriptan on regional cerebral blood flow (CBF) during migraine headache. Nine cases were examined by {sup 99m}Tc-ECD background subtraction method for the absolute value measurement of regional CBF before and after sumatriptan injection. rCBF except for occipital and perioccipital lobes, were increased 10-20% during migraine headache and significant decreases were observed by sumatriptan injection. Two cases of nine had transiently increased systemic blood pressure and cardiac pulse rate, however, all cases improved migraine headache after injection of sumatriptan. (author)

  12. Novel measurement of blood velocity profile using translating-stage optical method and theoretical modeling based on non-Newtonian viscosity model

    Science.gov (United States)

    Kim, Chang-Beom; Lim, Jaeho; Hong, Hyobong; Kresh, J. Yasha; Wootton, David M.

    2015-07-01

    Detailed knowledge of the blood velocity distribution over the cross-sectional area of a microvessel is important for several reasons: (1) Information about the flow field velocity gradients can suggest an adequate description of blood flow. (2) Transport of blood components is determined by the velocity profiles and the concentration of the cells over the cross-sectional area. (3) The velocity profile is required to investigate volume flow rate as well as wall shear rate and shear stress which are important parameters in describing the interaction between blood cells and the vessel wall. The present study shows the accurate measurement of non-Newtonian blood velocity profiles at different shear rates in a microchannel using a novel translating-stage optical method. Newtonian fluid velocity profile has been well known to be a parabola, but blood is a non-Newtonian fluid which has a plug flow region at the centerline due to yield shear stress and has different viscosities depending on shear rates. The experimental results were compared at the same flow conditions with the theoretical flow equations derived from Casson non-Newtonian viscosity model in a rectangular capillary tube. And accurate wall shear rate and shear stress were estimated for different flow rates based on these velocity profiles. Also the velocity profiles were modeled and compared with parabolic profiles, concluding that the wall shear rates were at least 1.46-3.94 times higher than parabolic distribution for the same volume flow rate.

  13. Auscultatory versus oscillometric measurement of blood pressure in octogenarians

    DEFF Research Database (Denmark)

    Rosholm, Jens-Ulrik; Pedersen, Sidsel Arnspang; Matzen, Lars;

    2012-01-01

    Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement.......Auscultatory measurement using a sphygmomanometer has been the predominant method for clinical estimation of blood pressure, but it is now rapidly being replaced by oscillometric measurement....

  14. A method for control of an implantable rotary blood pump for heart failure patients using noninvasive measurements.

    Science.gov (United States)

    Lim, Einly; Alomari, Abdul-Hakeem H; Savkin, Andrey V; Dokos, Socrates; Fraser, John F; Timms, Daniel L; Mason, David G; Lovell, Nigel H

    2011-08-01

    We propose a deadbeat controller for the control of pulsatile pump flow (Q(p) ) in an implantable rotary blood pump (IRBP). Noninvasive measurements of pump speed and current are used as inputs to a dynamical model of Q(p) estimation, previously developed and verified in our laboratory. The controller was tested using a lumped parameter model of the cardiovascular system (CVS), in combination with the stable dynamical models of Q(p) and differential pressure (head) estimation for the IRBP. The control algorithm was tested with both constant and sinusoidal reference Q(p) as input to the CVS model. Results showed that the controller was able to track the reference input with minimal error in the presence of model uncertainty. Furthermore, Q(p) was shown to settle to the desired reference value within a finite number of sampling periods. Our results also indicated that counterpulsation yields the minimum left ventricular stroke work, left ventricular end diastolic volume, and aortic pulse pressure, without significantly affecting mean cardiac output and aortic pressure.

  15. Blood Glucose Measurement Using Bioimpedance Technique

    Directory of Open Access Journals (Sweden)

    D. K. Kamat

    2014-01-01

    Full Text Available Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner AD5933. AD5933 is then interfaced with microcontroller LPC1768 using I2C bus for displaying reading on LCD. Results can also be stored in database using UART interface of LPC1768.

  16. Dry Blood Spots a Reliable Method for Measurement of Hepatitis B Viral Load in Resource-Limited Settings

    Science.gov (United States)

    Stene-Johansen, Kathrine; Yaqoob, Nadeem; Overbo, Joakim; Aberra, Hanna; Desalegn, Hailemichael; Berhe, Nega; Johannessen, Asgeir

    2016-01-01

    Background & Aims Hepatitis B virus (HBV) quantification is essential in the management of chronic hepatitis B, both to determine treatment eligibility and in the monitoring of treatment effect. This test, however, is rarely available in resource-limited settings due to high costs and stringent requirements for shipment and storage of plasma. Dried Blood Spots (DBS) can be a convenient alternative to plasma, but its use for HBV monitoring has not been investigated under real-life conditions in Africa. Methods The performance of DBS in HBV quantification was investigated using a modified commercial test (Abbott RealTime HBV assay). Paired DBS and plasma samples were collected from an HBV positive cohort in Addis Ababa, Ethiopia. DBS were stored at ambient temperature for 4–39 days before shipment to the laboratory. Results Twenty-six paired samples were selected covering the total range of quantification, from 2.14 log IU/ml to >7 log IU/ml. HBV was detected in 21 of 21 (100%) DBS from patients with a corresponding plasma viral load above 2.70 log IU/ml. The mean difference between plasma and DBS was 0.59 log IU/ml, and the correlation was strong (R2 = 0.92). In stability studies there was no significant change in DBS viral load after storage at room temperature for up to 12 weeks. Conclusions This study suggests that DBS can be a feasible and reliable alternative to plasma for quantification of HBV in resource-limited settings. DBS can expand access to antiviral treatment for patients in low- and middle-income countries. PMID:27820845

  17. [Application of wavelet transform on improving detecting precision of the non-invasive blood components measurement based on dynamic spectrum method].

    Science.gov (United States)

    Li, Gang; Men, Jian-Long; Sun, Zhao-Min; Wang, Hui-Quan; Lin, Ling; Tong, Ying; Zhang, Bao-Ju

    2011-02-01

    Time-varying noises in spectra collection process have influence on the prediction accuracy of quantitative calibration in the non-invasive blood components measurement which is based on dynamic spectrum (DS) method. By wavelet transform, we focused on the absorbance wave of fingertip transmission spectrum in pulse frequency band. Then we increased the signal to noise ratio of DS data, and improved the detecting precision of quantitative calibration. After carrying out spectrum data continuous acquisition of the same subject for 10 times, we used wavelet transform de-noising to increase the average correlation coefficient of DS data from 0.979 6 to 0.990 3. BP neural network was used to establish the calibration model of subjects' blood components concentration values against dynamic spectrum data of 110 volunteers. After wavelet transform de-noising, the correlation coefficient of prediction set increased from 0.677 4 to 0.846 8, and the average relative error was decreased from 15.8% to 5.3%. Experimental results showed that the introduction of wavelet transform can effectively remove the noise in DS data, improve the detecting precision, and accelerate the development of non-invasive blood components measurement based on DS method.

  18. Specific heat of rabbit blood measured by cooling method%冷却法测定家兔血液的比热

    Institute of Scientific and Technical Information of China (English)

    贾斌; 李建军; 温光楠

    2001-01-01

    目的 家兔血液比热是热稀释法测量家兔心输出量的重要修正系数.方法 根据牛顿冷却定律,采用同一容器盛装兔血或水,若两者温度与体积都基本相同,则水与兔血的散热规律基本相同,水的比热已知,便可求出兔血的比热;又利用同一系统测得标准100g·L-1NaCl溶液的比热值,求得测量系统误差,对所测兔血比热进行修正.结果 对测得的多组兔血比热数据进行合理筛选后,得到新鲜兔血测量值:0.886±0.022,经误差修正得到家兔血液比热:0.849±0.022;陈旧兔血测量值:1.020±0.021,经误差修正后:0.997±0.021.结论 冷却法测定家兔血液比热方法可靠,数据处理合理,结果可信.%AIM To determine specific heat of rabbit blood for calculatingcardiac output of rabbits by thermodilution. METHODS According to Newton's law of cooling, specific heat of rabbit blood was measured from that of water, by comparing the speed of temperature change of them measured respectively in the same system. The measured specific heat of rabbit blood was corrected with systematic error of specific heat of 100 g·L-1 NaCl solution measured in the same system. RESULTS Specific heat of fresh whole blood of rabbits was 0.886±0.022; After correction, 0.849±0.022; Blood after being stored, the specific heat changed, 1.020±0.021,and 0.997±0.021 after correction. CONCLUSION Corrected specific heat value of fresh blood is more reasonable, and the calculated cardiac output might be more accurate.

  19. The effects of fin rot disease and sampling method on blood chemistry and hematocrit measurements of winter flounder, Pseudopleuronectes americanus from New Haven Harbor (1987--1990).

    Science.gov (United States)

    Ziskowski, J; Mercaldo-Allen, R; Pereira, J J; Kuropat, C; Goldberg, R

    2008-04-01

    Winter flounder from New Haven, Connecticut were evaluated for fin rot disease. Blood samples collected from healthy and diseased fish were used to measure bilirubin, calcium, hematocrit, inorganic phosphorus, osmolality, and total protein. Blood measurements were significantly affected by the presence of fin rot disease and by sampling mode (bled immediately or after 18 h). A reduction in blood chemistry values was associated with fin rot disease. Logistic regression modeling was used to identify explanatory variables contributing to the fin rot outcome in winter flounder. Blood constituent levels were higher in fish bled immediately versus 18 h post-capture, especially among fish without fin rot, suggesting that a waiting period is necessary for blood values to stabilize following initial sampling stress. This study presents evidence that winter flounder blood chemistry and hematocrit measurements are affected by fin rot disease.

  20. A method for biomarker measurements in peripheral blood mononuclear cells isolated from anxious and depressed mice: β-arrestin 1 protein levels in depression and treatment

    Directory of Open Access Journals (Sweden)

    Indira eMENDEZ-DAVID

    2013-09-01

    Full Text Available A limited number of biomarkers in the central and peripheral systems which are known may be useful for diagnosing major depressive disorders and predicting the effectiveness of antidepressant treatments. Since 60% of depressed patients do not respond adequately to medication or are resistant to antidepressants, it is imperative to delineate more accurate biomarkers. Recent clinical studies suggest that β-arrestin 1 levels in human mononuclear leukocytes may be an efficient biomarker. If potential biomarkers such as β-arrestin 1 could be assessed from a source such as peripheral blood cells, then they could be easily monitored and used to predict therapeutic responses. However, no previous studies have measured β-arrestin 1 levels in peripheral blood mononuclear cells (PBMCs in anxious-depressive rodents.This study aimed to develop a method to detect β-arrestin protein levels through immunoblot analyses of mouse PBMCs isolated from whole blood. In order to validate the approach, β-arrestin levels were then compared in naïve, anxious/depressed mice, and anxious/depressed mice treated treated with a selective serotonin reuptake inhibitor (SSRI; fluoxetine, 18 mg/kg/day in the drinking water. The results demonstrated that mouse whole blood collected by submandibular bleeding permitted isolation of enough PBMCs to assess circulating proteins such as β-arrestin 1. β-arrestin 1 levels were successfully measured in healthy human subject and naïve mouse PBMCs. Interestingly, PBMCs from anxious/depressed mice showed significantly reduced β-arrestin 1 levels. These decreased β-arrestin 1 expression levels were restored to normal levels with chronic fluoxetine treatment. The results suggest that isolation of PBMCs from mice by submandibular bleeding is a useful technique to screen putative biomarkers of the pathophysiology of mood disorders and the response to antidepressants. In addition, these results confirm that β-arrestin 1 is a potential

  1. [Measurement of blood pressure variability and the clinical value].

    Science.gov (United States)

    Kékes, Ede; Kiss, István

    2014-10-19

    Authors have collected and analyzed literature data on blood pressure variability. They present the methods of blood pressure variability measurement, clinical value and relationships with target organ damages and risk of presence of cardiovascular events. They collect data about the prognostic value of blood pressure variability and the effects of different antihypertensive drugs on blood pressure variability. They underline that in addition to reduction of blood pressure to target value, it is essential to influence blood pressure fluctuation and decrease blood pressure variability, because blood pressure fluctuation presents a major threat for the hypertensive subjects. Data from national studies are also presented. They welcome that measurement of blood pressure variability has been included in international guidelines.

  2. Whole-blood culture is a valid low-cost method to measure monocytic cytokines - A comparison of cytokine production in cultures of human whole-blood, mononuclear cells and monocytes

    DEFF Research Database (Denmark)

    Damsgaard, Camilla T.; Lauritzen, Lotte; Calder, Philip C.

    2009-01-01

    assessed the intra- and inter-individual variation in cytokine production. In 64 healthy men (age 19-40 years) IL-6, TNF and IL-10 were measured by enzyme-linked immunosorbent assay in supernatants from whole-blood, PBMC and monocytes cultured 24 h with lipopolysaccharide (LPS) or UV-killed L acidophilus......Whole-blood and peripheral blood mononuclear cell (PBMC) cultures are used as non-validated surrogate measures of monocytic cytokine production. The aim of this investigation was to compare ex vivo cytokine production from human whole-blood and PBMC with that from isolated monocytes. We also...

  3. A new method of regional cerebral blood flow measurement using one-point arterial sampling based on the microsphere model with N-isopropyl-p-[[sup 123]I]-iodoamphetamine SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, I.; Takahashi, N.; Higuchi, T. (Niigata Univ. (Japan). School of Medicine); Ohkubo, M. (Niigata Univ. (Japan). Coll. of Biomedical Technology)

    1994-07-01

    We developed a new method for quantitative measurement of regional cerebral blood flow (rCBF) using one-point arterial sampling with N-isopropyl-p-[[sup 123]I]-iodoamphetamine ([sup 123]I-IMP) and single photon emission computed tomography (SPECT) based on the microsphere model. The one-point Ca(t) method provides fast, easy, accurate and non-invasive measurement of rCBF without inserting catheters and without treatment of arterial blood with octanol. (author).

  4. On-line dynamic measurement of blood viscosity, hematocrit and change of blood volume

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective: To develop an on-line system for the measurement of blood viscosity and hematocrit. The dynamic changes of the macrovascular blood volumes,microvascular blood volumes and the total blood volume were observed by means of calculating from the testing result. Methods: Applying traditional viscosity measurement principle and specific wavelength optic density measurement method, an on-line system for the measurement of blood viscosity and hematocrit was developed, and the A/D multifunctionai board and the testing circuit were designed by ourselves. The system was validated by experiments both in vitro and in vivo. Therapeutic effects of hypertonic saline dextran solution (HSD) and Lactatic Ringer's solution at the early stage after burn-blast combined injury were compared by this method. Results: The results showed that the system has attained the goal of the design. The changes of the blood viscosity and hematocrit could be detected effectively and continuously. The changes of macrovascular, microvascular and total blood volume could be calculated approximately. Conclusions: The system and the method can continuously on-line test the blood viscosity and hematocrit, and reveal the change and distribution of blood volumes more accurately and dearly in the therapy process by estimating changes of the macrovascular, microvascular and total blood volumes, respectively. It has confirmed that HSD treatment could increase blood pressure and attenuate tissue edema by significantly increasing total blood volume,improving macrocirculatory and microcirculatory blood volumes. This study suggested that it could be desirable to develop an experiment technique based on the method mentioned above.

  5. Ocular Blood Flow Autoregulation Mechanisms and Methods

    Directory of Open Access Journals (Sweden)

    Xue Luo

    2015-01-01

    Full Text Available The main function of ocular blood flow is to supply sufficient oxygen and nutrients to the eye. Local blood vessels resistance regulates overall blood distribution to the eye and can vary rapidly over time depending on ocular need. Under normal conditions, the relation between blood flow and perfusion pressure in the eye is autoregulated. Basically, autoregulation is a capacity to maintain a relatively constant level of blood flow in the presence of changes in ocular perfusion pressure and varied metabolic demand. In addition, ocular blood flow dysregulation has been demonstrated as an independent risk factor to many ocular diseases. For instance, ocular perfusion pressure plays key role in the progression of retinopathy such as glaucoma and diabetic retinopathy. In this review, different direct and indirect techniques to measure ocular blood flow and the effect of myogenic and neurogenic mechanisms on ocular blood flow are discussed. Moreover, ocular blood flow regulation in ocular disease will be described.

  6. Measuring blood oxygenation of pulsatile arteries using photoacoustic microscopy

    Science.gov (United States)

    Li, Qian; Yu, Tianhao; Li, Lin; Chai, Xinyu; Zhou, Chuanqing

    2016-10-01

    Heart pumps blood through the blood vessels to provide body with oxygen and nutrients. As the result, the blood flow, volume and oxygenation in arteries has a pulsatile nature. Measuring these pulsatile parameters enables more precise monitoring of oxygen metabolic rate and is thus valuable for researches and clinical applications. Photoacoustic microscopy (PAM) is a proven label-free method for in vivo measuring blood oxygenation at single blood vessel level. However, studies using PAM to observe the pulsatile nature of blood oxygenation in arteries were not reported. In this paper, we use optical-resolution PAM (OR-PAM) technology to study the blood oxygenation dynamics of pulsatile arteries. First, the ability of our OR-PAM system to accurately reflect the change of optical absorption in imaged objects is demonstrated in a phantom study. Then the system is used to image exposed cortical blood vessels of cat. The pulsatile nature of blood volume and oxygenation in arteries is clearly reflected in photoacoustic (PA) signals, whereas it's not observable in veins. By using a multi-wavelength laser, the dynamics of the blood oxygenation of pulsatile arteries in cardiac cycles can be measured, based on the spectroscopic method.

  7. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación

    OpenAIRE

    2002-01-01

    Objective. To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Mo...

  8. Detection and measurement of retinal blood vessel pulsatile motion

    Science.gov (United States)

    Xiao, Di; Frost, Shaun; Vignarajan, Janardhan; An, Dong; Tay-Kearney, Mei-Ling; Kanagasingam, Yogi

    2016-03-01

    Retinal photography is a non-invasive and well-accepted clinical diagnosis of ocular diseases. Qualitative and quantitative assessment of retinal images is crucial in ocular diseases related clinical application. Pulsatile properties caused by cardiac rhythm, such as spontaneous venous pulsation (SVP) and pulsatile motion of small arterioles, can be visualized by dynamic retinal imaging techniques and provide clinical significance. In this paper, we aim at vessel pulsatile motion detection and measurement. We proposed a novel approach for pulsatile motion measurement of retinal blood vessels by applying retinal image registration, blood vessel detection and blood vessel motion detection and measurement on infrared retinal image sequences. The performance of the proposed methods was evaluated on 8 image sequences with 240 images. A preliminary result has demonstrated the good performance of the method for blood vessel pulsatile motion observation and measurement.

  9. TREATMENT OF HYPERTENSION USING TELEMEDICAL HOME BLOOD PRESSURE MEASUREMENTS

    DEFF Research Database (Denmark)

    Hoffmann-Petersen, N; Lauritzen, T; Bech, J N

    2015-01-01

    of the measurements and subsequent communication by telephone or E-mail. In the control group, patients received usual care. Primary outcome was reduction in daytime ambulatory blood pressure measurements (ABPM) from baseline to 3 months' follow-up. RESULTS: In both groups, daytime ABPM decreased significantly....../181), p = 0.34. Blood pressure reduction in the TBPM group varied with the different practices. CONCLUSIONS: No further reduction in ABPM or number of patients reaching blood pressure targets was observed when electronic transmission of TBPM was applied in the treatment of hypertension by GPs. Thus......OBJECTIVE: Telemonitoring of home blood pressure measurements (TBPM) is a new and promising supplement to diagnosis, control and treatment of hypertension. We wanted to compare the outcome of antihypertensive treatment based on TBPM and conventional monitoring of blood pressure. DESIGN AND METHOD...

  10. Method for Reducing Pumping Damage to Blood

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor); Akkerman, James W. (Inventor); Aber, Gregory S. (Inventor); VanDamm, George Arthur (Inventor); Bacak, James W. (Inventor); Svejkovsky, Robert J. (Inventor); Benkowski, Robert J. (Inventor)

    1997-01-01

    Methods are provided for minimizing damage to blood in a blood pump wherein the blood pump comprises a plurality of pump components that may affect blood damage such as clearance between pump blades and housing, number of impeller blades, rounded or flat blade edges, variations in entrance angles of blades, impeller length, and the like. The process comprises selecting a plurality of pump components believed to affect blood damage such as those listed herein before. Construction variations for each of the plurality of pump components are then selected. The pump components and variations are preferably listed in a matrix for easy visual comparison of test results. Blood is circulated through a pump configuration to test each variation of each pump component. After each test, total blood damage is determined for the blood pump. Preferably each pump component variation is tested at least three times to provide statistical results and check consistency of results. The least hemolytic variation for each pump component is preferably selected as an optimized component. If no statistical difference as to blood damage is produced for a variation of a pump component, then the variation that provides preferred hydrodynamic performance is selected. To compare the variation of pump components such as impeller and stator blade geometries, the preferred embodiment of the invention uses a stereolithography technique for realizing complex shapes within a short time period.

  11. Pitfalls in blood pressure measurement in daily practice

    NARCIS (Netherlands)

    Houweling, ST; Kleefstra, N; Lutgers, HL; Groenier, KH; Meyboom-de Jong, B; Bilo, HJG

    2006-01-01

    Background. Accurate blood pressure (BP) readings and correctly interpreting the obtained values are of great importance. However, there is considerable variation in the different BP measuring methods suggested in guidelines and used in hypertension trials. Objective. To compare the different method

  12. Non-invasive methods for absolute cerebral blood flow measurement using {sup 99m}Tc-ECD: a study in healthy volunteers

    Energy Technology Data Exchange (ETDEWEB)

    Van Laere, K.; Dierckx, R. [Div. of Nuclear Medicine, Ghent University Hospital (Belgium); Dumont, F. [Radiopharmacy Department, Faculty of Pharmaceutical Sciences, Ghent University, Ghent (Belgium); Koole, M. [Medical Image and Signal Processing Department (MEDISIP), Faculty of Applied Sciences, Ghent University, Ghent (Belgium)

    2001-07-01

    Radionuclide angiography with technetium-99m ethyl cysteinate dimer (ECD) allows non-invasive estimation of absolute cerebral blood flow (CBF), either by graphical Patlak-Gjedde analysis (PGA) or by spectral analysis (SA). Other methods estimate CBF by means of single-point arterial or venous sampling. The aim of this study was to evaluate radionuclide scanning and single-point venous sampling as potential clinical non- to minimally invasive methods for CBF determination in a large set of carefully screened healthy volunteers over the adult age range. Eighty-three carefully screened healthy volunteers (20-81 years, 43 males, 40 females) underwent planar radionuclide angiography with 925 MBq {sup 99m}Tc-ECD. After correction for camera dead-time loss, hemispheric CBF was calculated from brain perfusion indices (BPI): BPI{sup G} for PGA and BPI{sup S} for SA. Of the volunteers, 49 also underwent venous sampling 6 min post injection, from which the lipophilic octanol extraction fraction and hemispheric brain fractionation index (BFI) were determined. All datasets were correlated and evaluated as a function of age and gender. Intrasubject variability for the BPI measurements was assessed in 11 volunteers by repeat study within 2 weeks of the first acquisition. Graphical and spectral analysis BPIs were strongly correlated (R=0.846, P<0.00001). This correlation coefficient increased to R=0.903 for the 74 cases in which graphical analysis was not hampered by temporal tracer retention in cervicobrachial venous valves. The BFI was weakly correlated to both BPI indices (BPI{sup G}: R=0.34, P=0.02; BPI{sup S}: R=0.31, P=0.04). The right hemisphere showed significant asymmetry for BPI{sup S} (AI=2.7%{+-}4.3%, P<0.001), in correspondence with previous {sup 99m}Tc-ECD data. BPI{sup G}, BPI{sup S} and BFI were all inversely related to age, with an increased gradient after the age of 55 years, while there was no significant gender difference. The ratio of BPI{sup G} to BIP{sup S

  13. Blood monitoring systems and methods thereof

    Science.gov (United States)

    Mir, Jose (Inventor); Zander, Dennis (Inventor)

    2012-01-01

    A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

  14. Estimating the measurement uncertainty in forensic blood alcohol analysis.

    Science.gov (United States)

    Gullberg, Rod G

    2012-04-01

    For many reasons, forensic toxicologists are being asked to determine and report their measurement uncertainty in blood alcohol analysis. While understood conceptually, the elements and computations involved in determining measurement uncertainty are generally foreign to most forensic toxicologists. Several established and well-documented methods are available to determine and report the uncertainty in blood alcohol measurement. A straightforward bottom-up approach is presented that includes: (1) specifying the measurand, (2) identifying the major components of uncertainty, (3) quantifying the components, (4) statistically combining the components and (5) reporting the results. A hypothetical example is presented that employs reasonable estimates for forensic blood alcohol analysis assuming headspace gas chromatography. These computations are easily employed in spreadsheet programs as well. Determining and reporting measurement uncertainty is an important element in establishing fitness-for-purpose. Indeed, the demand for such computations and information from the forensic toxicologist will continue to increase.

  15. Noise-Measuring Method

    DEFF Research Database (Denmark)

    Diamond, J. M.

    1965-01-01

    A noise-measuring method based on the use of a calibrated noise generator and an output meter with a special scale is described. The method eliminates the effect of noise contributions occurring in the circuits following the device under test....

  16. Finger temperature controller for non-invasive blood glucose measurement

    Science.gov (United States)

    Zhang, Xiqin; Ting, Choon Meng; Yeo, Joon Hock

    2010-11-01

    Blood glucose level is an important parameter for doctors to diagnose and treat diabetes. The Near-Infra-Red (NIR) spectroscopy method is the most promising approach and this involves measurement on the body skin. However it is noted that the skin temperature does fluctuate with the environmental and physiological conditions and we found that temperature has important influences on the glucose measurement. In-vitro and in-vivo investigations on the temperature influence on blood glucose measurement have been carried out. The in-vitro results show that water temperature has significant influence on water absorption. Since 90% of blood components are water, skin temperature of measurement site has significant influence on blood glucose measurement. Also the skin temperature is related to the blood volume, blood volume inside capillary vessels changes with skin temperature. In this paper the relationship of skin temperature and signal from the skin and inside tissue was studied at different finger temperatures. Our OGTT (oral glucose tolerance test) trials results show the laser signals follow the skin temperature trend and the correlation of signal and skin temperature is much stronger than the correlation of signal and glucose concentration. A finger heater device is designed to heat and maintain the skin temperature of measurement site. The heater is controlled by an electronic circuit according to the skin temperature sensed by a thermocouple that is put close to the measurement site. In vivo trials were carried out and the results show that the skin temperature significantly influences the signal fluctuations caused by pulsate blood and the average signal value.

  17. Randomized Comparison of the Therapeutic Effect of Acupuncture, Massage, and Tachibana-Style-Method on Stiff Shoulders by Measuring Muscle Firmness, VAS, Pulse, and Blood Pressure

    Directory of Open Access Journals (Sweden)

    Kazuhiro Tachibana

    2012-01-01

    Full Text Available To compare the therapeutic efficacy of acupuncture, massage, and Tachibana-Ryojutsu (one of Japanese traditional body balance therapy techniques (SEITAI, on stiff shoulders, the subjects’ muscle firmness, blood pressure, pulse, VAS, and body temperature were measured before and after the treatment. Forty-seven volunteer subjects gave written informed consent to participate in this study. The subjects were randomly divided into three groups to receive acupuncture, massage, or Tachibana-Ryojutsu. Each therapy lasted for 90 seconds. The acupuncture treatment was applied by a retaining-needle at GB-21, massage was conducted softly on the shoulders, and Tachibana-Ryojutsu treated only the muscles and joints from the legs to buttocks without touching the shoulders or backs. The study indicated that the muscle firmness and VAS of the Tachibana-Ryojutsu group decreased significantly in comparison with the acupuncture and massage groups after treatment.

  18. Use of dried blood for measurement of trans fatty acids

    Directory of Open Access Journals (Sweden)

    Ramakrishnan Lakshmy

    2009-07-01

    Full Text Available Abstract Background Fatty acid measurements especially trans fatty acid has gained interest in recent times. Among the various available biomarkers, adipose tissue is considered to be the best for the long term dietary intake but the invasive nature of tissue aspiration reduces its utility. Phlebotomy is a much less invasive method of sample collection when a large number of participants are involved in the study and therefore is an alternative, most suitable for large population based studies. In the present study fatty acid (with special emphasis on trans fatty acid extraction from blood spotted and dried on filter paper was carried out to simplify the sample collection procedure and transportation. Methods Blood samples were collected from 19 healthy volunteers. The blood was spotted (30 spots of 10 μl each on filter paper, dried at room temperature and stored at 4°C in zip-lock poly bags. For comparison whole blood stored at -70°C was simultaneously analyzed. Results A good agreement was seen between trans fatty acid values obtained in dried blood and whole blood as evident from the pearson correlation coefficients ('r' for monounsaturated (trans 0.70 and for polyunsaturated (trans 0.692 respectively. The intraclass correlation coefficient for monounsaturated trans was 0.805 and for polyunsarurated trans was 0.776. Conclusion Dried blood spots can be used for trans fatty acid analysis.

  19. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  20. Noninvasive blood pressure measurement scheme based on optical fiber sensor

    Science.gov (United States)

    Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan

    2016-10-01

    Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.

  1. Blood cell counting and classification by nonflowing laser light scattering method

    Science.gov (United States)

    Yang, Ye; Zhang, Zhenxi; Yang, Xinhui; Jiang, Dazong; Yeo, Joon Hock

    1999-11-01

    A new non-flowing laser light scattering method for counting and classifying blood cells is presented. A linear charge- coupled device with 1024 elements is used to detect the scattered light intensity distribution of the blood cells. A pinhole plate is combined with the CCD to compete the focusing of the measurement system. An isotropic sphere is used to simulate the blood cell. Mie theory is used to describe the scattering of blood cells. In order to inverse the size distribution of blood cells from their scattered light intensity distribution, Powell method combined with precision punishment method is used as a dependent model method for measurement red blood cells and blood plates. Non-negative constraint least square method combined with Powell method and precision punishment method is used as an independent model for measuring white blood cells. The size distributions of white blood cells and red blood cells, and the mean diameter of red blood cells are measured by this method. White blood cells can be divided into three classes: lymphocytes, middle-sized cells and neutrocytes according to their sizes. And the number of blood cells in unit volume can also be measured by the linear dependence of blood cells concentration on scattered light intensity.

  2. [The landmarks of the measurement of cerebral blood flow].

    Science.gov (United States)

    István, Nyáry

    2008-01-30

    History of the measurement of local cerebral blood flow may cover a period of one and a half centuries. Parallel forthcoming of both theoretical and technical development were the key elements of ensuing progress resulting in the present state, when by the aid of in vivo blood flow and metabolic maps, we can visualize locales of brain functioning and their interconnections. Two theoretical landmarks should be mentioned in this historic process. First, the work of Adolf Fick, as the starter of quantitative measurements in this field, and Seymour Kety's model of a single, homogenously perfused tissue element. The solution of this model, in the form of Kety's equation is still fundamental to present day blood flow mapping techniques. Among the numerous investigators over the past years, two Hungarian scientist can be named as major contributors. Kálmán Sántha made substantial studies with continuous registration of local cerebral blood flow by the aid of thermocouples, while Emil P6sztor invented the hydrogen clearance method for the measurement of local cerebral blood flow both in human and in animal studies.

  3. HbA1c measurements from dried blood spots : validation and patient satisfaction

    NARCIS (Netherlands)

    Fokkema, Margaretha; Bakker, Andries J; de Boer, Fokje; Kooistra, Jeltsje; de Vries, Sifra; Wolthuis, Albert

    2009-01-01

    Background: This study evaluates HbA1c measurements from dried blood spots collected on filter paper and compares HbA1c from filter paper (capillary blood) with HbA1c measured in venous blood. Methods: Patient satisfaction was evaluated using a questionnaire. The performance with the filter paper me

  4. Accurate blood flow measurements: are artificial tracers necessary?

    Directory of Open Access Journals (Sweden)

    Christian Poelma

    Full Text Available Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case, as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements. These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented.

  5. Accurate blood flow measurements: are artificial tracers necessary?

    Science.gov (United States)

    Poelma, Christian; Kloosterman, Astrid; Hierck, Beerend P; Westerweel, Jerry

    2012-01-01

    Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case), as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements). These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented.

  6. ON THE USEFULNESS OF FINGER BLOOD-PRESSURE MEASUREMENTS FOR STUDIES ON MENTAL WORKLOAD

    NARCIS (Netherlands)

    VELDMAN, JBP; RUDDEL, H; ROBBE, HWJ; Mulder, Lambertus; Mulder, Gysbertus

    1991-01-01

    Two experiments were conducted to explore the usefulness of the Penaz method for non-invasive, continuous finger blood pressure measurements during mental stress testing. In the first study, blood pressure was measured with the Penaz method, in the second it was measured intra-arterially. Two differ

  7. Leg blood flow measurements using venous occlusion plethysmography during head-up tilt.

    NARCIS (Netherlands)

    Kooijman, M.; Poelkens, F.; Rongen, G.A.; Smits, P.; Hopman, M.T.E.

    2007-01-01

    We tested whether venous occlusion plethysmography (VOP) is an appropriate method to measure calf blood flow (CBF) during head-up tilt (HUT). CBF measured with VOP was compared with superficial femoral artery blood flow as measured by Doppler ultrasound during incremental tilt angles. Measurements o

  8. An evaluation of blood smears made by a new method using a spinner and diluted blood.

    Science.gov (United States)

    Nourbakhsh, M; Atwood, J G; Raccio, J; Seligson, D

    1978-12-01

    Blood smears were prepared with the use of a spinner, which rotated with a fixed velocity for a fixed time. All blood samples used for spun smears were diluted with a fixed ratio of buffered isotonic saline solution. Distribution of cells in these smears was found to be random. The average number of cells per unit area was substantially uniform from place to place on the same slide and on multiple slides made with the smae sample. The distribution of leukocytes by type was also iniform. For different blood samples, the average number of cells per unit area in the smears correlated well with the measured cell concentrations per unit volume in the samples for leukocytes, erythrocytes and platelets. Leukocyte differential counts on replicate spun smears using the same bloods also agreed to within the sampling error. They similarly agreed with differential counts on pulled smears made from undiluted samples of the same bloods. With few exceptions, erythrocytic morphology on the spun smears was comparable to that on the good areas of pulled smears made with undiluted samples of the same bloods. Nearly all the spun smears were suitable for both viual and fully automated hematologic examination for leukocytes, erythrocytes, and platelets. This was true over nearly the whole area of each spun slide. In these ways this spinner method makes smears whose consistently high quality is little affected by either the properties of the blood sample or the skill of maker.

  9. Body mass index and blood pressure measurement during pregnancy.

    LENUS (Irish Health Repository)

    Hogan, Jennifer L

    2012-02-01

    OBJECTIVE: The accurate measurement of blood pressure requires the use of a large cuff in subjects with a high mid-arm circumference (MAC). This prospective study examined the need for a large cuff during pregnancy and its correlation with maternal obesity. METHODS: Maternal body mass index (BMI), fat mass, and MAC were measured. RESULTS: Of 179 women studied, 15.6% were obese. With a BMI of level 1 obesity, 44% needed a large cuff and with a BMI of level 2 obesity 100% needed a large cuff. CONCLUSION: All women booking for antenatal care should have their MAC measured to avoid the overdiagnosis of pregnancy hypertension.

  10. [Measurement of cerebral blood flow using phase-contrast MRI].

    Science.gov (United States)

    Obata, T; Shishido, F; Koga, M; Ikehira, H; Kimura, F; Yoshida, K

    1997-07-01

    The development of phase-contrast magnetic resonance imaging(P-C MRI) provides a noninvasive method for measurement of volumetric blood flow(VFR). The VFR of the left and right internal carotid arteries and basilar artery were measured using P-C MRI, and total cerebral blood flow(tCBF) was calculated by summing up the VFR values in three vessels. We investigated the changes in these blood flows as influenced from age, head size, height, weight, body surface area and handedness. Moreover, regional CBF(rCBF) was measured by combining with the single photon emission computed tomography(SPECT) of 123I. The blood flows were 142 +/- 58 mL/ min(mean +/- SD) in the basilar artery, 229 +/- 86 mL/min in the left, 223 +/- 58 mL/min in the right internal carotid artery, and tCBF was 617 +/- 128 mL/min(Ref. Magn Resn Imaging 14:P. 1143, 1996). Significant increases were observed in head-size-related change of VFR in the basilar artery and height-related change of tCBF. The value of rCBF was easily acquired in combination with SPECT. Phase-contrast MRI is useful for a noninvasive and rapid analysis of cerebral VFR and has potential for clinical use.

  11. Pressure Gradient Estimation Based on Ultrasonic Blood Flow Measurement

    Science.gov (United States)

    Nitta, Naotaka; Homma, Kazuhiro; Shiina, Tsuyoshi

    2006-05-01

    Mechanical load to the blood vessel wall, such as shear stress and pressure, which occurs in blood flow dynamics, contribute greatly to plaque rupture in arteriosclerosis and to biochemical activation of endothelial cells. Therefore, noninvasive estimations of these mechanical loads are able to provide useful information for the prevention of vascular diseases. Although the pressure is the dominant component of mechanical load, for practical purposes, the pressure gradient is also often important. So far, we have investigated the estimation of the kinematic viscosity coefficient using a combination of the Navier-Stokes equations and ultrasonic velocity measurement. In this paper, a method for pressure gradient estimation using the estimated kinematic viscosity coefficient is proposed. The validity of the proposed method was investigated on the basis of the analysis with the data obtained by computer simulation and a flow phantom experiment. These results revealed that the proposed method can provide a valid estimation of the pressure gradient.

  12. Blood flow measurements and clot detection with nearinfrared spectroscopy

    OpenAIRE

    Rossow, MJ; Gatto, R.; D'amico, E.; Mantulin, WW; Gratton, E

    2006-01-01

    Detecting impeded blood flow and locating the clot causing it is a major challenge in neurosurgery. We propose an instrument that uses near-infrared spectroscopy to simultaneously detect clots and measure blood flow. © 2006 Optical Society of America.

  13. [An integrated system of blood pressure measurement with bluetooth communication].

    Science.gov (United States)

    Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu

    2012-07-01

    The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.

  14. Ocular Blood Flow Autoregulation Mechanisms and Methods

    OpenAIRE

    Xue Luo; Yu-meng Shen; Meng-nan Jiang; Xiang-feng Lou; Yin Shen

    2015-01-01

    The main function of ocular blood flow is to supply sufficient oxygen and nutrients to the eye. Local blood vessels resistance regulates overall blood distribution to the eye and can vary rapidly over time depending on ocular need. Under normal conditions, the relation between blood flow and perfusion pressure in the eye is autoregulated. Basically, autoregulation is a capacity to maintain a relatively constant level of blood flow in the presence of changes in ocular perfusion pressure and va...

  15. Optically measured microvascular blood flow contrast of malignant breast tumors.

    Directory of Open Access Journals (Sweden)

    Regine Choe

    Full Text Available Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS, a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92-2.63; tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94-2.66, and using normal tissue in the contralateral breast was 2.27 (1.90-2.70. Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.

  16. Chronic intestinal ischaemia: measurement of the total splanchnic blood flow.

    Science.gov (United States)

    Zacho, Helle D

    2013-04-01

    A redundant collateral network between the intestinal arteries is present at all times. In case of ischaemia in the gastrointestinal tract, the collateral blood supply can develop further, thus accommodating the demand for oxygen even in the presence of significant stenosis or occlusion of the intestinal arteries without clinical symptoms of intestinal ischaemia. Symptoms of ischemia develop when the genuine and collateral blood supply no longer can accommodate the need for oxygen. Atherosclerosis is the most common cause of obliteration in the intestinal arteries. In chronic intestinal ischaemia (CII), the fasting splanchnic blood flow (SBF) is sufficient, but the postprandial increase in SBF is inadequate and abdominal pain will therefore develop in relation to food intake causing the patient to eat smaller meals at larger intervals with a resulting weight loss. Traditionally, the CII-diagnosis has exclusively been based upon morphology (angiography) of the intestinal arteries; however, substantial discrepancies between CII-symptoms and the presence of atherosclerosis/stenosis in the intestinal arteries have been described repeatedly in the literature impeding the diagnosis of CII. This PhD thesis explores a method to determine the total SBF and its potential use as a diagnostic tool in patients suspected to suffer from CII. The SBF can be measured using a continuous infusion of a tracer and catheterisation of a hepatic vein and an artery. By measuring the SBF before and after a standard meal it is possible to assess the ability or inability to enhance the SBF and thereby diagnosing CII. In Study I, measurement of SBF was tested against angiography in a group of patients suspected to suffer from CII due to pain and weight loss. A very good agreement between the postprandial increase in SBF and angiography was found. The method was validated against a well-established method independent of the hepatic extraction of tracer using pAH in a porcine model (study II

  17. Method for measurement of the blood-brain barrier permeability in the perfused mouse brain: application to amyloid-beta peptide in wild type and Alzheimer's Tg2576 mice.

    Science.gov (United States)

    LaRue, Barbra; Hogg, Elizabeth; Sagare, Abhay; Jovanovic, Suzana; Maness, Lawrence; Maurer, Calvin; Deane, Rashid; Zlokovic, Berislav V

    2004-09-30

    The role of transport exchanges of neuroactive solutes across the blood-brain barrier (BBB) is increasingly recognized. To take full advantage of genetically altered mouse models of neurodegenerative disorders for BBB transport studies, we adapted a brain perfusion technique to the mouse. During a carotid brain perfusion with a medium containing sheep red blood cells and mock plasma, the physiological parameters in the arterial inflow, regional cerebral blood flow (14C-iodoantipyrine autoradiography), ultrastructural integrity of the tissue, barrier to lanthanum, brain water content, energy metabolites and lactate levels remain unchanged. Amyloid-beta peptides (Abeta) were iodinated by lactoperoxidase method. Non-oxidized mono-iodinated Abeta monomers were separated by HPLC (as confirmed by MALDI-TOF spectrometry) and used in transport measurements. Transport of intact 125I-Abeta40 across the BBB was time- and concentration-dependent in contrast to negligible 14C-inulin uptake. In 5-6 months old Alzheimer's Tg2576 mice, Abeta40 BBB transport was increased by >eight-fold compared to age-matched littermate controls, and was mediated via the receptor for advanced glycation endproducts. We conclude the present arterial brain perfusion method provides strictly controlled environment in cerebral microcirculation suitable for examining transport of rapidly and slowly penetrating molecules across the BBB in normal and transgenic mice.

  18. Measurements and Terminology of Different Measure Methods

    Institute of Scientific and Technical Information of China (English)

    FANG Fang; ZHANG Wei-yuan; ZHANG Wen-bin

    2005-01-01

    Body measuring is very important for garment sizing and pattern making. In this paper, we study the difference of the landmarks between the traditional method and 3D scanner and we also select the 19 circumference measurements,29 height and length measurements, 18 breadth and depth measurements and 3 other measurements, which are quite important in fashion body measuring, to compare the terminology of them in these two measuring method. 3D scanners seem better than the traditional method on these aspects, which are the number of measurements, speed,privacy and data accuracy, but they are limited on measuring posture. And there is no uniform standard for the scanners and the definitions of the measurements in the scanners are diversified.

  19. Quantitating error in blood flow measurements with radioactive microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Austin, R.E. Jr.; Hauck, W.W.; Aldea, G.S.; Flynn, A.E.; Coggins, D.L.; Hoffman, J.I.

    1989-07-01

    Accurate determination of the reproducibility of measurements using the microsphere technique is important in assessing differences in blood flow to different organs or regions within organs, as well as changes in perfusion under various experimental conditions. The sources of error of the technique are briefly reviewed. In addition, we derived a method for combining quantifiable sources of error into a single estimate that was evaluated experimentally by simultaneously injecting eight or nine sets of microspheres (each with a different radionuclide label) into four anesthetized dogs. Each nuclide was used to calculate blood flow in 145-190 myocardial regions. We compared each flow determination (using a single nuclide label) with a weighted mean for the piece (based on the remaining nuclides). The difference was defined as ''measured'' error. In all, there were a total of 5,975 flow observations. We compared measured error with theoretical estimates based on the Poisson error of radioactive disintegration and microsphere entrapment, nuclide separation error, and reference flow error. We found that combined estimates based on these sources completely accounted for measured error in the relative distribution of microspheres. In addition, our estimates of the error in measuring absolute flows (which were established using microsphere reference samples) slightly, but significantly, underestimated measured error in absolute flow.

  20. New algorithm and system for measuring size distribution of blood cells

    Institute of Scientific and Technical Information of China (English)

    Cuiping Yao(姚翠萍); Zheng Li(李政); Zhenxi Zhang(张镇西)

    2004-01-01

    In optical scattering particle sizing, a numerical transform is sought so that a particle size distribution can be determined from angular measurements of near forward scattering, which has been adopted in the measurement of blood cells. In this paper a new method of counting and classification of blood cell, laser light scattering method from stationary suspensions, is presented. The genetic algorithm combined with nonnegative least squared algorithm is employed to inverse the size distribution of blood cells. Numerical tests show that these techniques can be successfully applied to measuring size distribution of blood cell with high stability.

  1. Laser Doppler flowmetry to measure changes in cerebral blood flow.

    Science.gov (United States)

    Sutherland, Brad A; Rabie, Tamer; Buchan, Alastair M

    2014-01-01

    Laser Doppler flowmetry (LDF) is a method by which relative cerebral blood flow (CBF) of the cortex can be measured. Although the method is easy to employ, LDF only measures relative CBF, while absolute CBF cannot be quantified. LDF is useful for investigating CBF changes in a number of different applications including neurovascular and stroke research. This chapter will prepare the reader for rodent experiments using LDF with two preparations. The closed skull preparation can be used to monitor CBF with an intact skull, but in adult rats, thinning of the skull is required to obtain an accurate cortical CBF signal. The open skull preparation requires a craniotomy to expose the surface of the brain and the LDF probe is held close to the surface to measure cerebral perfusion.

  2. The measurement and interpretation of morphine in blood.

    Science.gov (United States)

    Logan, B K; Oliver, J S; Smith, H

    1987-01-01

    A method for the determination of morphine is post-mortem blood by HPLC with electrochemical detection is described. Blood morphine levels in post-mortem cases are reported and the importance of these in causing death is discussed. These post-mortem levels are compared further with morphine levels in the blood of patients receiving morphine as an analgesic.

  3. Pulsed photoacoustic Doppler flow measurements in blood-mimicking phantoms

    Science.gov (United States)

    Brunker, J.; Beard, P.

    2011-03-01

    The feasibility of making spatially resolved measurements of blood flow using pulsed photoacoustic Doppler techniques has been explored. Doppler time shifts were quantified via cross-correlation of pairs of photoacoustic waveforms generated within a blood-simulating phantom using pairs of laser light pulses. The photoacoustic waves were detected using a focussed or planar PZT ultrasound transducer. For each flow measurement, a series of 100 waveform pairs was collected. Previous data processing methods involved rejection of poorly correlated waveform pairs; the modal velocity value and standard deviation were then extracted from the selected distribution of velocity measurements. However, the data selection criteria used in this approach is to some extent arbitrary. A new data analysis protocol, which involves averaging the 100 cross-correlation functions and thus uses all of the measured data, has been designed in order to prevent exclusion of outliers. This more rigorous approach has proved effective for quantifying the linear motion of micron-scale absorbers imprinted on an acetate sheet moving with velocities in the range 0.14 to 1.25 ms-1. Experimental parameters, such as the time separation between the laser pulses and the transducer frequency response, were evaluated in terms of their effect on the accuracy, resolution and range of measurable velocities. The technique was subsequently applied to fluid phantoms flowing at rates less than 5 mms-1 along an optically transparent tube. Preliminary results are described for three different suspensions of phenolic resin microspheres, and also for whole blood. Velocity information was obtained even under non-optimal conditions using a low frequency transducer and a low pulse repetition frequency. The distinguishing advantage of pulsed rather than continuous-wave excitation is that spatially resolved velocity measurements can be made. This offers the prospect of mapping flow within the microcirculation and thus

  4. Local blood flow measured by fluorescence excitation of nonradioactive microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Y.; Payne, B.D.; Aldea, G.S.; McWatters, C.; Husseini, W.; Mori, H.; Hoffman, J.I.; Kaufman, L. (Univ. of California, San Francisco (USA))

    1990-05-01

    An X-ray fluorescence system with low Compton background and high counting efficiency was developed to measure regional blood flow with nonradioactive microspheres. The performance of the system was tested in vitro by counting mixed aqueous solutions of either Mo, Ag, and I; Nb, Ag, and Ba; or Zr, Mo, Rh, Ag, Sn, I, and Ba, as well as a mixture of Ag and Ba nonradioactive microspheres. Mixtures containing 2-20 ppm of each element were counted for 10 min by the fluorescence system, and the individual elements in mixtures of three to seven nonradioactive elements were measured with high accuracy. The best counting statistics were obtained for Ag. For 10-min counts, the system measures as few as 120 Ag microspheres with 30% standard deviation but measures 800 Ag microspheres per sample with 3.6% standard deviation. We compared regional myocardial blood flows determined simultaneously by fluorescence and radioactive microsphere methods; the latter samples were counted by a 3-in. NaI (Tl) well detector and pulse-height analyzer. The radioactive and nonradioactive measurements showed good correlations.

  5. Colour measurement and white blood cell recognition

    CERN Document Server

    Gelsema, E S

    1972-01-01

    As a part of a collaboration with NEMCH aimed at the automation of the differential white blood cell count, studies have been made of the different possibilities for using colour to help in the recognition process. Results are presented comparing data obtained with a microspectrophotometer and with a simulated three-colour scanner.

  6. Can cerebral blood volume be measured reproducibly with an improved near infrared spectroscopy system?

    NARCIS (Netherlands)

    Ven, M.T.P. van de; Colier, W.N.J.M.; Sluijs, M.C. van der; Walraven, D.; Oeseburg, B.; Folgering, H.T.M.

    2001-01-01

    In some circumstances, cerebral blood volume (CBV) can be used as a measure for cerebral blood flow. A new near infrared spectroscope was used for determining the reproducibility of CBV measurements assessed by the O2-method. Twenty-seven healthy subjects were investigated. An intrasubject coefficie

  7. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  8. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...... access blood flow measured before and after every procedure. Two methods, catheter-based thermodilution and Doppler ultrasound, were compared to the reference method of ultrasound dilution. Catheter-based thermodilution and Doppler ultrasound were performed during the endovascular procedures while flow...

  9. Calcium measurement methods

    Directory of Open Access Journals (Sweden)

    CarloAlberto Redi

    2010-09-01

    Full Text Available Rightly stressed by prof. Wolfgang Walz in the Preface to the series Neuromethods series, the “careful application of methods is probably the most important step in the process of scientific inquiry”. Thus, I strongly suggest to all those interested in calcium signaling and especially to the new-comers in the hot topic of neuroscience (which has so much space even in science-society debate for its implications in legal issues and in the judge-decision process to take profit from this so well edited book. I am saying this since prof. Verkhratsky and prof. Petersen......

  10. Blood pressure measurement in hemodialysis: The importance of the measurement technique.

    Science.gov (United States)

    Kubrusly, M; de Oliveira, Claudia Maria Costa; Silva, R P; Pinheiro, M A; Rocha, M B C; Magalhães, R M

    2016-03-01

    Systemic arterial hypertension contributes to the high cardiovascular morbidity in hemodialysis (HD) patients, but the accuracy of blood pressure (BP) measurement in this population has not been well studied. To evaluate the agreement between BP measurement using the routine measurement technique (usual method) and the technique recommended by the VII Joint (standard method). This cross-sectional study enrolled 124 patients in a single center who had undergone dialysis for more than three months and were 18 years of age or older. The BP was verified at the start of dialysis by the nursing team (usual method) and by the researchers (standard method). The agreement between the systolic and diastolic BP (SBP and DBP) measurements was tested by the Bland-Altman analysis. A difference in BP measurement higher than ±5 mm Hg was considered clinically significant. The studied group had a mean age of 53.2 years. The average difference between routine and standard BP measurement was -6 mm Hg for SBP (limits of agreement: -40.1-28 mm Hg; P measured by both methods was observed in 69.4% of the patients for SBP and in 61.3% for DBP. The disagreement between the results of different BP measurement methods in HD patients was significant and the BP was underestimated using the usual BP method. BP measurement standardization should be encouraged to avoid errors in diagnosis and therapy.

  11. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: a validation study Hemoglobina medida por Hemocue y por un método de referencia en sangre venosa y capilar: estudio de validación

    Directory of Open Access Journals (Sweden)

    Lynnette Neufeld

    2002-06-01

    Full Text Available Objective. To assess the comparability of hemoglobin concentration (Hb in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn and to document the influence of type of blood (capillary or venous and analysis method on anemia prevalence estimates. Material and Methods. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Results. Capillary blood had higher Hb (+0.5g/dl than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3g/dl. Specificity to detect anemia was adequate (>0.90 but sensitivity was low for capillary blood assessed by Hemocue (Objetivo. Evaluar la comparabilidad de la concentración de hemoglobina (Hb en sangre venosa y capilar medida por Hemocue y por espectrofotómetro automatizado (Celldyn, así como documentar la influencia del tipo de sangre (capilar o venosa y del método de análisis sobre la prevalencia de anemia. Material y métodos. De febrero a mayo de 2000, se recolectaron muestras de sangre capilar y venosa en 72 adultos y niños en el Hospital del Niño Morelense, Cuernavaca, Morelos, México. Se determinaron los niveles de Hb con los métodos Hemocue y Celldyn. Las cifras de Hb estimadas se compararon con el coeficiente de concordancia y la prueba pareada de t de Student. También se comparó la sensibilidad y especificidad para el diagnóstico de anemia, utilizando sangre de los dos tipos y métodos de análisis. Resultados. La Hb fue mayor en sangre capilar comparada con sangre venosa

  12. Theoretical model of blood flow measurement by diffuse correlation spectroscopy

    Science.gov (United States)

    Sakadžić, Sava; Boas, David A.; Carp, Stefan

    2017-02-01

    Diffuse correlation spectroscopy (DCS) is a noninvasive method to quantify tissue perfusion from measurements of the intensity temporal autocorrelation function of diffusely scattered light. However, DCS autocorrelation function measurements in tissue better match theoretical predictions based on the diffusive motion of the scatterers than those based on a model where the advective nature of blood flow dominates the stochastic properties of the scattered light. We have recently shown using Monte Carlo (MC) simulations and assuming a simplistic vascular geometry and laminar flow profile that the diffusive nature of the DCS autocorrelation function decay is likely a result of the shear-induced diffusion of the red blood cells. Here, we provide theoretical derivations supporting and generalizing the previous MC results. Based on the theory of diffusing-wave spectroscopy, we derive an expression for the autocorrelation function along the photon path through a vessel that takes into account both diffusive and advective scatterer motion, and we provide the solution for the DCS autocorrelation function in a semi-infinite geometry. We also derive the correlation diffusion and correlation transfer equation, which can be applied for an arbitrary sample geometry. Further, we propose a method to take into account realistic vascular morphology and flow profile.

  13. MEASUREMENT OF REGIONAL BONE BLOOD FLOW IN THE CANINE MANDIBULAR RAMUS USING RADIOLABELLED TOAD RED BLOOD CELLS

    Institute of Scientific and Technical Information of China (English)

    毛驰; 王翰章

    1994-01-01

    Toad red blood cells were used to measure regional bone blood flow in the canine mandibular ramus.The blood cells were labelled with sodium pertechnetate and fixed in 10% formalin;they were 22×15 μm in size and had a specific gravity close to that of dog red blood cells.These cells had no discernible effect on systemic hemody-namics after injection,did not agglutinate,were well mixed and evenly distributed throughout the body,and were completely extracted in one circulation through the mandible.The mandibular ramus was divided into six regions,and the blood flow rates in each were found to be similar to those reported in previous studies with radiolabelled carbonized,microspheres.Furthermore,the blood flow distribution pattern of the mandibular ramus determined in this study was identical to that of our previous study using the bone-seeking radionuclide method.We suggest that radiolabelled toad red blood cells are an ideal marker for measuring regional blood flow in the canine mandible.

  14. Patients' experiences and opinions of home blood pressure measurement.

    Science.gov (United States)

    Rickerby, J; Woodward, J

    2003-07-01

    Regular measurement of the blood pressure (BP) is necessary to monitor the treatment of hypertension, and self-measurement is one technique of obtaining such measurements. The aim of this study was to investigate the experiences of individuals who have carried out home BP measurement. A qualitative method using semistructured interviews was used with 13 subjects. These were adults with hypertension who had previous experience of measuring their own BP, and were recruited to the study from one UK general medical practice. Interviews were recorded and transcribed, and data from the interviews have been analysed using phenomenological principles and identifying 'meaning units.' The findings suggest that participants were willing to carry out home measurements and several were pleased to have been asked to be more involved in their own management. All found the technique straightforward. Most noted marked variability in the day-to-day BP measurements. Several exhibited the 'white coat' phenomenon (spuriously raised BP in certain settings only). Some participants showed considerable know-ledge of hypertension and its consequences. They reported being aware of their own BP level and whether this was within acceptable limits. They also reported being willing to take further measurements, and to consider adjusting their treatment in the light of these measurements. Other participants showed less knowledge and enthusiasm, and considered the management of hypertension to be the doctor's job. The findings suggest that for some individuals home BP measurement is acceptable. They also help to explain why, for some individuals, it is not. Using the findings, a number of changes to current practice could be made, which might make home measurements more acceptable and easier to perform. As a result, a new proforma for use in everyday practice has been designed. The study shows that there is considerable scope for sharing BP measurement and management decisions in hypertension with

  15. Perioperative blood saving measures in total hip and knee arthroplasty

    NARCIS (Netherlands)

    Horstmann, W.G.

    2011-01-01

    This dissertation explores and discusses different aspects of blood loss and blood-saving measures in total hip and knee arthroplasty. Background: Worldwide, approximately 1 million total hip and 1 million total knee prostheses are implanted each year. Total hip arthroplasty and total knee art

  16. Optoacoustic measurements of human placenta and umbilical blood oxygenation

    Science.gov (United States)

    Nanovskaya, T. N.; Petrov, I. Y.; Petrov, Y.; Patrikeeva, S. L.; Ahmed, M. S.; Hankins, G. D. V.; Prough, D. S.; Esenaliev, R. O.

    2016-03-01

    Adequate oxygenation is essential for normal embryogenesis and fetal growth. Perturbations in the intrauterine oxidative environment during pregnancy are associated with several pathophysiological disorders such as pregnancy loss, preeclampsia, and intrauterine growth restriction. We proposed to use optoacoustic technology for monitoring placental and fetal umbilical blood oxygenation. In this work, we studied optoacoustic monitoring of oxygenation in placenta and umbilical cord blood ex vivo using technique of placenta perfusion. We used a medical grade, nearinfrared, tunable, optoacoustic system developed and built for oxygenation monitoring in blood vessels and in tissues. First, we calibrated the system for cord blood oxygenation measurements by using a CO-Oximeter (gold standard). Then we performed validation in cord blood circulating through the catheters localized on the fetal side of an isolated placental lobule. Finally, the oxygenation measurements were performed in the perfused placental tissue. To increase or decrease blood oxygenation, we used infusion of a gas mixture of 95% O2 + 5% CO2 and 95% N2 + 5% CO2, respectively. In placental tissue, up to four cycles of changes in oxygenation were performed. The optoacoustically measured oxygenation in circulating cord blood and in placental lobule closely correlated with the actual oxygenation data measured by CO-Oximeter. We plan to further test the placental and cord blood oxygenation monitoring with optoacoustics in animal and clinical studies.

  17. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard;

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent o...

  18. Dynamic noise correction for IVUS quantitative volume blood flow: methods and numerical validation.

    NARCIS (Netherlands)

    Lupotti, F.A.; Korte, C.L. de; Mastik, F.; Steen, A.F.W. van der

    2002-01-01

    In recent years, a new method to measure transverse blood flow based on the decorrelation of the radio-frequency (RF) signals, has been developed. Transverse blood flow estimation may be influenced by noise. In this paper, we investigated a new correlation-based method for noise correction. The deco

  19. Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos.

    Science.gov (United States)

    Lee, Jung Yeop; Ji, Ho Seong; Lee, Sang Joon

    2007-10-01

    The hemodynamic characteristics of blood flow are important in the diagnosis of circulatory diseases, since such diseases are related to wall shear stress of cardiovascular vessels. In chicken embryos at early stages of development, it is possible to directly visualize blood flow inside blood vessels. We therefore employed a micro-PIV technique to assess blood flow in extraembryonic venous and arterial blood vessels of chicken embryos, using red blood cells (RBCs) as tracers and obtaining flow images of RBCs using a high-speed CMOS camera. The mean velocity field showed non-Newtonian flow characteristics. The blood flow in two venous vessels merged smoothly into the Y-shaped downstream vein without any flow separation or secondary flow. Vorticity was high in the inner regions, where the radius of curvature varied greatly. A periodic variation of temporally resolved velocity signals, due to beating of the heart, was observed in arterial blood vessels. The pulsating frequency was obtained by fast Fourier transform analysis using the measured velocity data. The measurement technique used here was useful in analyzing the hemodynamic characteristics of in vivo blood flow in chicken embryos.

  20. Combination of phlebography and sanguinous measurement of venous blood pressure

    Energy Technology Data Exchange (ETDEWEB)

    Weber, J.

    1988-07-01

    Phlebographic visualisation offers the highest spatial resolution of all imaging methods both in respect of veins of the leg and pelvis and of the abdomen. Phlebography offers optimal conditions for assessing morphological changes at the veins and in their direct neighbourhood. No quantitative information is available via phlebography if haemodynamics are disturbed; qualitative information is yielded merely to a restricted extent (by assessing flow velocity and collaterals). Direct sanguinous measurement of venous blood pressure is particularly suitable for the quantitative and qualitative assessment of disturbed haemodynamic conditions; in this respect it stands out among the function tests based on the employment of apparatures. If it is combined with phlebography, it is possible not only to optimise the diagnostic yield in the hands of one investigator, but also to reduce the invasiveness of both methods to one single puncture, since the puncture needle is at the same time also an instrument to measure the pressure. The article points out the possibilities and limitations of combining a) ascending phlebography of the leg and pelvis with peripheral venous pressure measurement (phlebodynamometry) and b) visualisation of the veins of the pelvis and vena cava inferior with central sanguinous venous pressure measurement (CP). Indicatious and technical execution are described.

  1. Automated methods of corrosion measurement

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Bech-Nielsen, Gregers; Reeve, John Ch

    1997-01-01

    Measurements of corrosion rates and other parameters connected with corrosion processes are important, first as indicators of the corrosion resistance of metallic materials and second because such measurements are based on general and fundamental physical, chemical, and electrochemical relations....... Hence improvements and innovations in methods applied in corrosion research are likeliy to benefit basic disciplines as well. A method for corrosion measurements can only provide reliable data if the beckground of the method is fully understood. Failure of a method to give correct data indicates a need...... to revise assumptions regarding the basis of the method, which sometimes leads to the discovery of as-yet unnoticed phenomena. The present selection of automated methods for corrosion measurements is not motivated simply by the fact that a certain measurement can be performed automatically. Automation...

  2. Measurement of cerebral blood flow using phase contrast magnetic resonance imaging and duplex ultrasonography.

    Science.gov (United States)

    Khan, Muhammad Ayaz; Liu, Jie; Tarumi, Takashi; Lawley, Justin Stevan; Liu, Peiying; Zhu, David C; Lu, Hanzhang; Zhang, Rong

    2017-02-01

    Phase contrast magnetic resonance imaging (PC-MRI) and color-coded duplex ultrasonography (CDUS) are commonly used for measuring cerebral blood flow in the internal carotid (ICA) and vertebral arteries. However, agreement between the two methods has been controversial. Recent development of high spatial and temporal resolution blood vessel wall edge-detection and wall-tracking methods with CDUS increased the accuracy and reliability of blood vessel diameter, hence cerebral blood flow measurement. The aim of this study was to compare the improved CDUS method with 3 T PC-MRI for cerebral blood flow measurements. We found that cerebral blood flow velocity measured in the ICA was lower using PC-MRI than CDUS (left ICA: PC-MRI, 18.0 ± 4.2 vs. CDUS, 25.6 ± 8.6 cm/s; right ICA: PC-MRI, 18.5 ± 4.8 vs. CDUS, 26.6 ± 6.7 cm/s, both p blood flow velocity measured in the left vertebral artery with PC-MRI was also lower than CDUS, but no differences in vertebral artery diameter were observed between the methods. Dynamic changes and/or intrinsic physiological fluctuations may have caused these differences in vessel diameter and velocity measurements between the methods. However, estimation of volumetric cerebral blood flow was similar and correlated between the methods despite the presence of large individual differences. These findings support the use of CDUS for cerebral blood flow measurements in the ICA and vertebral artery.

  3. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    discussions which allowed to receive direct feedback from the point of view of different disciplines. This book is based on the contributions of that workshop and is intended to convey an overview of the different aspects involved in the prediction. The individual chapters are based on the presentations given...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic...... on the net effect of meals on the blood glucose concentration. By assuming that all major unexplained glycemic excursions can be vi Preface attributed to oral glucose ingestion, a meal vector is estimated which significantly improves the mathematical model. Results are shown on three patients during...

  4. Adult derived genetic blood pressure scores and blood pressure measured in different body postures in young children

    NARCIS (Netherlands)

    Jansen, Maria Ac; Dalmeijer, Geertje W.; Visseren, Frank Lj; van der Ent, Cornelis K; Leusink, Maarten; Onland-Moret, N Charlotte; Der Zee, Anke H Maitland Van; Grobbee, Diederick E; Uiterwaal, CSPM

    2017-01-01

    Aims Several genes are related to blood pressure (BP) levels in adults, but it is largely unknown whether these genes also determine BP early in life. Methods Systolic BP (SBP) and diastolic BP (DBP) were measured in 720 5-year-old children from the WHeezing-Illnesses-STudy-LEidsche-Rijn (WHISTLER)

  5. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples.

    Science.gov (United States)

    Batterman, Stuart A; Chernyak, Sergey; Su, Feng-Chiao

    2016-01-01

    The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs) is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS). Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs), chlorinated hydrocarbons (CHCs), polychlorinated biphenyls (PCBs), and brominated diphenyl ethers (PBDEs). Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models. Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R (2) > 0.80), and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  6. Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood and Dried Blood Spot Samples

    Directory of Open Access Journals (Sweden)

    Stuart A Batterman

    2016-04-01

    Full Text Available The preferred sampling medium for measuring human exposures of persistent organic compounds (POPs is blood, and relevant sample types include whole blood, plasma, and dried blood spots (DBS. Because information regarding the performance and comparability of measurements across these sample types is limited, it is difficult to compare across studies. This study evaluates the performance of POP measurements in plasma, whole blood and DBS, and presents the distribution coefficients needed to convert concentrations among the three sample types. Blood samples were collected from adult volunteers, along with demographic and smoking information, and analyzed by GC/MS for organochlorine pesticides (OCPs, chlorinated hydrocarbons (CHCs, polychlorinated biphenyls (PCBs, and brominated diphenyl ethers (PBDEs. Regression models were used to evaluate the relationships between the sample types and possible effects of personal covariates. Distribution coefficients also were calculated using physically-based models.Across all compounds, concentrations in plasma were consistently the highest; concentrations in whole blood and DBS samples were comparable. Distribution coefficients for plasma to whole blood concentrations ranged from 1.74 to 2.26 for pesticides/CHCs, averaged 1.69 ± 0.06 for the PCBs, and averaged 1.65 ± 0.03 for the PBDEs. Regression models closely fit most chemicals (R2 > 0.80, and whole blood and DBS samples generally showed very good agreement. Distribution coefficients estimated using biologically-based models were near one and did not explain the observed distribution. Among the study population, median concentrations of several pesticides/CHCs and PBDEs exceeded levels reported in the 2007-2008 National Health and Nutrition Examination Survey, while levels of other OCPs and PBDEs were comparable or lower. Race and smoking status appeared to slightly affect plasma/blood concentration ratios for several POPs. The experimentally

  7. Fluid-filled blood pressure measurement systems.

    Science.gov (United States)

    Li, J K; van Brummelen, A G; Noordergraaf, A

    1976-05-01

    The performance of catheter-manometer systems for the measurement of pulsatile pressure has been evaluated by both experimental techniques and theoretical considerations. The former approach has shown, on occasion, multiple maxima in the amplitude response. The latter has been approached in a variety of ways, ranging from extreme lumping to application of transmission line theory while employing different configurations in the system's representation. Multiple maxima have also been seen, The present paper identifies the sources of the differences found and compares the relative merits of various theoretical approaches. It introduces the compliance of the system as a figure of merit and provides a simple first-order approximation formula for evaluation of the quality of a system. Damping and impedance matching to improve the system's frequency response were studied. It was found that they were not needed in a very stiff or a very compliant system, nor should one worry about the representation of such a system.

  8. Enzymatic method for determining ketone body ratio in arterial blood.

    Science.gov (United States)

    Uno, S; Takehiro, O; Tabata, R; Ozawa, K

    1995-12-01

    We have developed a new, sensitive, and rapid method for measuring the ketone body concentration in arterial blood and determining the arterial blood ketone body ratio. The procedure involves the sequential use of the enzymes 3-hydroxybutyrate dehydrogenase (3-HBDH; EC 1.1.1.30) and NADH oxidase, followed by a color-generating reaction with the hydrogen peroxide produced by the oxidase reaction. The amount of oxidized chromogen produced is proportional to the 3-hydroxybutyrate (3-HBA) concentration. The acetoacetate (AcAc) concentration is obtained after complete conversion of the AcAc to 3-HBA, in the presence of 3-HBDH. The total 3-HBA concentration is measured and then subtracted from the total ketone body concentration to give the AcAc concentration. This procedure may be applied to plasma samples and the absorbance change measured with an automated chemistry analyzer. Ketone body concentration may be determined over the range 0 to 400 mumol/L. The analysis takes approximately 12 min and requires only 30 microL of plasma.

  9. Measurements of vitamin B12 in human blood serum using resonance Raman spectroscopy

    Science.gov (United States)

    Tsiminis, G.; Schartner, E. P.; Brooks, J. L.; Hutchinson, M. R.

    2016-12-01

    Vitamin B12 (cobalamin and its derivatives) deficiency has been identified as a potential modifiable risk factor for dementia and Alzheimer's disease. Chronic deficiency of vitamin B12 has been significantly associated with an increased risk of cognitive decline. An effective and efficient method for measuring vitamin B12 concentration in human blood would enable ongoing tracking and assessment of this potential modifiable risk factor. In this work we present an optical sensor based on resonance Raman spectroscopy for rapid measurements of vitamin B12 in human blood serum. The measurement takes less than a minute and requires minimum preparation (centrifuging) of the collected blood samples.

  10. Single-cell measurement of red blood cell oxygen affinity

    CERN Document Server

    Caprio, Di; Higgins, John M; Schonbrun, Ethan

    2015-01-01

    Oxygen is transported throughout the body by hemoglobin in red blood cells. While the oxygen affinity of blood is well understood and is routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of red blood cell volume and hemoglobin concentration are taken millions of times per day by clinical hematology analyzers and are important factors in determining the health of the hematologic system. To better understand the variability and determinants of oxygen affinity on a cellular level, we have developed a system that quantifies the oxygen saturation, cell volume and hemoglobin concentration for individual red blood cells in high-throughput. We find that the variability in single-cell saturation peaks at an oxygen partial pressure of 2.5%, which corresponds to the maximum slope of the oxygen-hemoglobin dissociation curve. In addition, single-cell oxygen affinity is positively correlated with hemoglobin concentr...

  11. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    Science.gov (United States)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  12. The application of blood flow measurements to the study of aging muscle.

    Science.gov (United States)

    McCully, K K; Posner, J D

    1995-11-01

    Blood flow to skeletal muscle is a potentially important factor in the reduction of muscle function associated with aging (sarcopenia). The main influence of reduced blood flow capacity on muscle function is in limiting oxidative metabolism. Direct measures of blood flow include: intravital-microscopy, plethysmography, radioactive microspheres, 133Xenon washout, thermodilution, and Doppler ultrasound. Indirect measurement of blood flow includes arm-to-ankle pressure index and the rate of phosphocreatine recovery after exercise. Several new methodologies have been developed to evaluate muscle blood flow, including color-Doppler imaging, magnetic resonance imaging/angiography (MRI/MRA), and near-infrared spectroscopy (NIRS). As adaptations of traditional techniques, these methods promise more precise information under less invasive conditions. MRI is an expensive and technically challenging method able to measure vessel location, blood flow, and wall diameter in blood vessels throughout the cardiac cycle. Color-Doppler provides excellent temporal resolution blood flow throughout the cardiac cycle, along with some anatomical information. NIRS is an inexpensive and portable technology that can measure changes in oxygen saturation and provide information on tissue oxygen delivery in studies of frailer and more difficult-to-study subjects. Muscle blood flow is not thought to limit oxidative metabolism under normal conditions in young individuals. However, it is not clear what happens to muscle blood flow in healthy older individuals. Reduced capillary density, less maximal blood flow, and a slower hyperemic flow response have been reported in some, but not all, studies. Further studies with the newer methodologies are needed to re-examine age-related changes in muscle blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Blood pressure self-measurement in the obstetric waiting room

    DEFF Research Database (Denmark)

    Wagner, Stefan; Kamper, Christina H.; Toftegaard, Thomas Skjødeberg

    2013-01-01

    Background: Pregnant diabetic patients are often required to self- measure their blood pressure in the waiting room before consulta- tion. Currently used blood pressure devices do not guarantee valid measurements when used unsupervised. This could lead to misdi- agnosis and treatment error. The a...... support. This could include context-aware patient adherence aids and clinical decision support systems for automatically validating self-measured data based on e-health and telemedicine technology....... of this study was to investigate current use of blood pressure self-measurement in the waiting room in order to identify challenges that could influence the resulting data quality. Also, we wanted to investigate the potential for addressing these challenges with e-health and telemedicine technology. Subjects...

  14. Critical Evaluation of Blood Volume Measurements during Hemodialysis

    NARCIS (Netherlands)

    Dasselaar, Judith J.; van der Sande, Frank M.; Franssen, Casper F. M.

    2012-01-01

    Devices that continuously measure relative blood volume (RBV) changes during hemodialysis (HD) are increasingly used for the prevention of dialysis hypotension and fine-tuning of dry weight. However, RBV measurements are subject to various limitations. First, RBV devices provide information on relat

  15. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately.

  16. Proportion and characteristics of patients who measure their blood pressure at home: Nationwide survey in Slovenia

    Directory of Open Access Journals (Sweden)

    Petek-Šter Marija

    2009-01-01

    Full Text Available Introduction. Home blood pressure monitoring has several advantages over blood pressure monitoring at a physician's office, and has become a useful instrument in the management of hypertension. Objective. To explore the rate and characteristics of patients who measure their blood pressure at home. Methods. A sample of 2,752 patients with diagnosis of essential arterial hypertension was selected from 12596 consecutive office visitors. Data of 2,639 patients was appropriate for analysis. The data concerning home blood pressure measurement and patients' characteristics were obtained from the patients' case histories. Results 1,835 (69.5% out of 2,639 patients measured their blood pressure at home. 1,284 (70.0% of home blood pressure patients had their own blood pressure measurement device. There were some important differences between these two groups: home blood pressure patients were more frequently male, of younger age, better educated, from urban area, mostly non-smokers, more likely to have diabetes mellitus and ischemic heart disease and had higher number of co-morbidities and were on other drugs beside antihypertensive medication. Using the logistic regression analysis we found that the most powerful predictors of home blood pressure monitoring had higher education level than primary school OR=1.80 (95% CI 1.37-2.37, non-smoking OR=2.16 (95% CI 1.40-3.33 and having a physician in urban area OR=1.32 (95% CI 1.02-1.71. Conclusion. Home blood pressure monitoring is popular in Slovenia. Patients who measured blood pressure at home were different from patients who did not. Younger age, higher education, non-smoking, having a physician in urban area and longer duration of hypertension were predictors of home blood pressure monitoring.

  17. Determining tumor blood flow parameters from dynamic image measurements

    Science.gov (United States)

    Libertini, Jessica M.

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth[l]. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community[2], this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake[3]. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  18. Determining tumor blood flow parameters from dynamic image measurements

    Energy Technology Data Exchange (ETDEWEB)

    Libertini, Jessica M [Division of Applied Mathematics, Brown University, Providence, Rhode Island 02906 (United States)], E-mail: Jessica_Libertini@brown.edu

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community, this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  19. Blood pressure monitor with a position sensor for wrist placement to eliminate hydrostatic pressure effect on blood pressure measurement.

    Science.gov (United States)

    Sato, Hironori; Koshimizu, Hiroshi; Yamashita, Shingo; Ogura, Toshihiko

    2013-01-01

    Accurate measurement of blood pressure at wrist requires the heart and wrist to be kept at the same level to avoid the effects of hydrostatic pressure. Although a blood pressure monitor with a position sensor that guides appropriate forearm angle without use of a chair and desk has already been proposed, a similar functioning device for measuring upper arm blood pressure with a chair and desk is needed. In this study, a calculation model was first used to explore design of such a system. The findings were then implemented into design of a new blood pressure monitor. Results of various methods were compared. The calculation model of the wrist level from arthrosis angles and interarticulars lengths was developed and considered using published anthropometric dimensions. It is compared with 33 volunteer persons' experimental results. The calculated difference of level was -4.1 to 7.9 (cm) with a fixed chair and desk. The experimental result was -3.0 to 5.5 (cm) at left wrist and -2.1 to 6.3(cm) at right wrist. The absolute difference level equals ±4.8 (mmHg) of blood pressure readings according to the calculated result. This meets the AAMI requirements for a blood pressure monitor. In the conclusion, the calculation model is able to effectively evaluate the difference between the heart and wrist level. Improving the method for maintaining wrist to heart level will improve wrist blood pressure measurement accuracy when also sitting in the chair at a desk. The leading angle of user's forearm using a position sensor is shown to work for this purpose.

  20. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  1. Imaging FTIR emissivity measurement method

    Science.gov (United States)

    Burdette, Edward M.; Nichols, C. Spencer; Lane, Sarah E.; Prussing, Keith F.; Cathcart, J. Michael

    2013-09-01

    Though many materials behave approximately as greybodies across the long-wave infrared (LWIR) waveband, certain important infrared (IR) scene modeling materials such as brick and galvanized steel exhibit more complex optical properties1. Accurately describing how non-greybody materials interact relies critically on the accurate incorporation of the emissive and reflective properties of the in-scene materials. Typically, measured values are obtained and used. When measured using a non-imaging spectrometer, a given material's spectral emissivity requires more than one collection episode, as both the sample under test and a standard must be measured separately. In the interval between episodes changes in environment degrade emissivity measurement accuracy. While repeating and averaging measurements of the standard and sample helps mitigate such effects, a simultaneous measurement of both can ensure identical environmental conditions during the measurement process, thus reducing inaccuracies and delivering a temporally accurate determination of background or `down-welling' radiation. We report on a method for minimizing temporal inaccuracies in sample emissivity measurements. Using a LWIR hyperspectral imager, a Telops Hyper-Cam2, an approach permitting hundreds of simultaneous, calibrated spectral radiance measurements of the sample under test as well as a diffuse gold standard is described. In addition, we describe the data reduction technique to exploit these measurements. Following development of the reported method, spectral reflectance data from 10 samples of various materials of interest were collected. These data are presented along with comments on how such data will enhance the fidelity of computer models of IR scenes.

  2. In vivo lateral blood flow velocity measurement using speckle size estimation.

    Science.gov (United States)

    Xu, Tiantian; Hozan, Mohsen; Bashford, Gregory R

    2014-05-01

    In previous studies, we proposed blood measurement using speckle size estimation, which estimates the lateral component of blood flow within a single image frame based on the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is "smeared") if blood flow is in the same direction as the electronically controlled transducer line selection in a 2-D image. In this observational study, the clinical viability of ultrasound blood flow velocity measurement using speckle size estimation was investigated and compared with that of conventional spectral Doppler of carotid artery blood flow data collected from human patients in vivo. Ten patients (six male, four female) were recruited. Right carotid artery blood flow data were collected in an interleaved fashion (alternating Doppler and B-mode A-lines) with an Antares Ultrasound Imaging System and transferred to a PC via the Axius Ultrasound Research Interface. The scanning velocity was 77 cm/s, and a 4-s interval of flow data were collected from each subject to cover three to five complete cardiac cycles. Conventional spectral Doppler data were collected simultaneously to compare with estimates made by speckle size estimation. The results indicate that the peak systolic velocities measured with the two methods are comparable (within ±10%) if the scan velocity is greater than or equal to the flow velocity. When scan velocity is slower than peak systolic velocity, the speckle stretch method asymptotes to the scan velocity. Thus, the speckle stretch method is able to accurately measure pure lateral flow, which conventional Doppler cannot do. In addition, an initial comparison of the speckle size estimation and color Doppler methods with respect to computational complexity and data acquisition time indicated potential time savings in blood flow velocity estimation using speckle size estimation. Further studies are needed for calculation of the speckle stretch method

  3. Donating blood for research: a potential method for enhancing customer satisfaction of permanently deferred blood donors

    Science.gov (United States)

    Waller, Daniel; Thijsen, Amanda; Garradd, Allira; Hayman, Jane; Smith, Geoff

    2017-01-01

    Background Each year, a large number of individuals in Australia are deferred from donating blood. A deferral may have a negative impact on donor satisfaction and subsequent word-of-mouth communication. The Australian Red Cross Blood Service (the Blood Service) is, therefore, investigating options for managing service interactions with deferred donors to maintain positive relationships. While public research institutes in Australia have established independent research donor registries, other countries provide programmes allowing deferred donors to donate blood for research via blood collection agencies. This study examined attitudes towards donating blood for research use in a sample of permanently deferred Australian donors. Materials and methods Donors permanently deferred because of a risk of variant Creutzfeldt-Jakob disease (n=449) completed a postal survey that examined attitudes towards research donation. Results The majority of participants were interested in donating blood for research (96%), and joining a registry of research donors (93%). Participants preferred to donate for transfusion or clinical research, and were willing to travel large distances. Results indicated that positive attitudes towards the Blood Service would be extended if the opportunity to donate blood was provided. These findings indicate a desire for continued engagement with the Blood Service despite deferral. Discussion Donating blood for research is a potential way of maintaining positive relationships with permanently deferred donors which also benefits the health research community. Through maintaining positive relationships with deferred donors, positive word-of-mouth activity can be stimulated. Further work is needed to determine the feasibility of implementing research donation through the Blood Service in Australia. PMID:26674813

  4. Measuring the antioxidant capacity of blood plasma using potentiometry.

    Science.gov (United States)

    Tessutti, L S; Macedo, D V; Kubota, L T; Alves, A A

    2013-10-15

    The use of potentiometry to measure plasma antioxidant capacity to contribute to oxidative stress evaluation is presented. In this assay, plasma (n=60) diluted (0.3 to 1 ml) in phosphate buffer, pH 7.4, NaCl 9%, was submitted to potentiometry. A platinum wire was the working electrode and saturated calomel the reference. The results are presented as the difference between sample and buffer potential (ΔE). ΔE presented a good inverse correlation with added increasing concentrations of ascorbate (2.5-75 μmol/L; R=-0.99), urate (9.0-150 μmol/L; R=-0.99), and bilirubin (0.78-13 μmol/L; R=-0.99). Increase in the antioxidant capacity decreased ΔE. Depletion of the antioxidant capacity by tert-butylhydroperoxide (6.5-50 μmol/L) presented a direct correlation (0.97) with ΔE. Furthermore, ΔE presented an inverse correlation (R=-0.99) with increased antioxidant capacity of plasma (FRAP) induced by the addition of ascorbate (2.5-75 μmol/L). The response of the potentiometric method proved be adequate for measuring the plasma antioxidant depletion induced by acute exhaustive exercise in rats (control, n=15; exercised, n=15). This exercise decreased the concentration of urate (ppotentiometry for evaluating the antioxidant capacity of blood plasma samples.

  5. Stability of glycated hemoglobin measurement in whole blood with routine methods%全血糖化血红蛋白用常规方法测定的稳定性研究

    Institute of Scientific and Technical Information of China (English)

    王冬环; 张传宝

    2009-01-01

    目的 探讨全血糖化血红蛋白HbA1c在不同储存条件下分别用Tosoh G7、罗氏/日立7170A和NycoCard READERⅡ测定的稳定性.方法 收集3个糖化血红蛋白水平的乙二胺四乙酸抗凝及1个水平的肝素抗凝全血样本,冻存管分装,分别储存在-80℃、-20℃、4℃、室温(15~25 ℃)和37℃.分别在第1、2、5、7、9、14、21、28、35、42、49、56、63和70 d用3种方法进行测定.结果在-80℃储存的全血样本在研究期间无论是用东曹G7方法还是用罗氏/日立7170A方法测定结果稳定,东曹G7的变异系数(CV)为0.54%~1.22%;罗氏/日立7170A的CV为0.86%~1.82%;样本用东曹G7测定的稳定性为:-20℃可稳定14 d,4 ℃ 63 d,室温5 d,37 ℃少于1 d;罗氏/日立7170A方法 为:-20℃21 d,4 ℃ 42 d,室温7 d,37℃少于1 d;NycoCard READER Ⅱ:4℃9 d,室温少于1 d.结论 不同方法测定全血样本的稳定性是特异的,不同温度下允许保存时间不同.%Objective To investigate the stability of glycated hemoglobin HbA1c in whole blood sample measured by Tosoh G7, Roche/Hitachi 7170A and NycoCard READER Ⅱ under different storage conditions. Methods Three whole blood samples (EDTA anticoagulated) with different glycated hemoglobin levels and one whole blood sample (heparin anticoagulated) were collected and stored at -80 ℃, -20 ℃, 4 ℃,room temperature(15 -25 ℃), and 37 ℃ HbA1c was analyzed by each method on days 1, 2, 5, 7, 9, 14, 21,28, 35, 42, 49, 56, 63 and 70 respectively. Results The results of sample stored at -80 ℃ appear to be stable for Tesoh G7 and Roche/Hitachi 7170A method. The coefficients of variation (CV) for Tosoh G7 was 0.54%-1.22%. The CV for Roche/Hitachi 7170A was 0.86% -1.82%. When samples was detected with Tosoh G7 method, the results was consistent when the sample was stored at -20 ℃ for 14 days, 4 ℃ for 63 days, room temperature for 5 days, and 37 ℃ for less than 1 day. When samples was detected with Roche/Hitachi 7170A

  6. Comparisons of home blood glucose testing and glycated protein measurements.

    Science.gov (United States)

    Lee, P D; Sherman, L D; O'Day, M R; Rognerud, C L; Ou, C N

    1992-04-01

    We examined the relationships between 4 glycated protein assays and home blood glucose monitoring (HBGM) in 26 children with poorly-controlled insulin-dependent diabetes mellitus (IDDM) during a period of improved management. At 2 week intervals for 6 visits (12 weeks in total), HBGM records were collected and a blood sample was obtained for measurement of glycated proteins and glucose. Assays included glycated hemoglobin (GHb) and glycated serum proteins (GP) by boronate affinity chromatography, hemoglobin A1C by PolyCAT A high performance liquid chromatography (HAC) and fructosamine (FA). All 4 glycated protein levels declined significantly over the 12 week period. Significant correlations between the glycated proteins and HBGM were observed over 2 week intervals. None of the 4 assays were affected by the glucose level in the sample. Changes in mean HBGM readings over 2 week intervals were correlated with both FA and GP with wide prediction intervals. Over cumulative 2 week intervals, which may more accurately reflect longitudinal trends, all 4 glycated proteins were correlated with mean HBGM readings. At each cumulative interval, GHb and GP showed the largest variation with MBG, while FA showed the least variation with MBG. Our data indicate that of the 4 assays tested, FA has limited clinical values as compared to other glycated protein assays, whereas assays based on boronate affinity chromatography (GHb and GP) provide the most useful clinical indicators of short-term changes in glycemic control. The clinical utility of a new HPLC method for determination of glycated hemoglobins is also demonstrated.

  7. Classification of diabetes and measurement of blood glucose concentration noninvasively using near infrared spectroscopy

    Science.gov (United States)

    Li, Zhe; Li, Gang; Yan, Wen-Juan; Lin, Ling

    2014-11-01

    Developing noninvasive blood glucose monitoring method is an to immense need to alleviate the pain and suffering of diabetics associated with the frequent pricking of skin for taking blood sample. A hybrid algorithm for multivariate calibration is proposed to improve the prediction performance of classification of diabetes and measurement of blood glucose concentration by near infrared (NIR) spectroscopy noninvasively. The algorithm is based on wavelet prism modified uninformative variable elimination approach (WP-mUVE) combined with least squares support vector machine (LSSVM), named as WP-mUVE-LSSVM. The method is successfully applied to diabetic classification experiment (in vivo) and blood glucose concentration measurement experiment (in vivo) respectively. Human tongue is selected as the measuring site in this study. To evaluate effectiveness of pretreatment method and quality of calibration models, several usually used pretreatment methods and kernel functions of LSSVM are introduced comparing with our method. Higher quality data is obtained by our pretreatment method owing to the elimination of varying background and noise of spectra data simultaneously. Better prediction accuracy and adaptability are obtained by LSSVM model with radial basis kernel function. The results indicate that WP-mUVE-LSSVM holds promise for the classification of diabetes and measurement of blood glucose concentration noninvasively based on human tongue using NIR spectroscopy.

  8. Accuracy of point-of-care blood glucose measurements in critically ill patients in shock.

    Science.gov (United States)

    Garingarao, Carlo Jan Pati-An; Buenaluz-Sedurante, Myrna; Jimeno, Cecilia Alegado

    2014-09-01

    A widely used method in monitoring glycemic status of ICU patients is point-of-care (POC) monitoring devices. A possible limitation to this method is altered peripheral blood flow in patients in shock, which may result in over/underestimations of their true glycemic status. This study aims to determine the accuracy of blood glucose measurements with a POC meter compared to laboratory methods in critically ill patients in shock. POC blood glucose was measured with a glucose-1-dehydrogenase-based reflectometric meter. The reference method was venous plasma glucose measured by a clinical chemistry analyzer (glucose oxidase-based). Outcomes assessed were concordance to ISO 15197:2003 minimum accuracy criteria for glucose meters, bias in glucose measurements obtained by the 2 methods using Bland-Altman analysis, and clinical accuracy through modified error grid analysis. A total of 186 paired glucose measurements were obtained. ISO 2003 accuracy criteria were met in 95.7% and 79.8% of POC glucose values in the normotensive and hypotensive group, respectively. Mean bias for the normotensive group was -12.4 mg/dL, while mean bias in the hypotensive group was -34.9 mg/dL. POC glucose measurements within the target zone for clinical accuracy were 90.2% and 79.8% for the normotensive and hypotensive group, respectively. POC blood glucose measurements were significantly less accurate in the hypotensive subgroup of ICU patients compared to the normotensive group. We recommend a lower threshold in confirming POC blood glucose with a central laboratory method if clinically incompatible. In light of recently updated accuracy standards, we also recommend alternative methods of glucose monitoring for the ICU population as a whole regardless of blood pressure status.

  9. Invasively Measured Aortic Systolic Blood Pressure and Office Systolic Blood Pressure in Cardiovascular Risk Assessment

    DEFF Research Database (Denmark)

    Laugesen, Esben; Knudsen, Søren T; Hansen, Klavs W;

    2016-01-01

    Aortic systolic blood pressure (BP) represents the hemodynamic cardiac and cerebral burden more directly than office systolic BP. Whether invasively measured aortic systolic BP confers additional prognostic value beyond office BP remains debated. In this study, office systolic BP and invasively...

  10. Blood cell manufacture: current methods and future challenges.

    Science.gov (United States)

    Timmins, Nicholas E; Nielsen, Lars K

    2009-07-01

    Blood transfusion depends on availability of donor material, and concerns over supply and safety have spurred development of methods to manufacture blood from stem cells. Current methods could theoretically yield therapeutic doses of red blood cells (RBCs) and platelets. However, due to the very large number of cells required to have any impact on supply (currently 10(19) RBC/year in the US), realization of routine manufacture faces significant challenges. Current yields are orders of magnitude too low for production of meaningful quantities, and the physical scale of the problem is a challenge in itself. We discuss these challenges in relation to current methods and how it might be possible to realize limited 'blood pharming' of neutrophils in the near future.

  11. A spectral and morphologic method for white blood cell classification

    Science.gov (United States)

    Wang, Qian; Chang, Li; Zhou, Mei; Li, Qingli; Liu, Hongying; Guo, Fangmin

    2016-10-01

    The identification of white blood cells is important as it provides an assay for diagnosis of various diseases. To overcome the complexity and inaccuracy of traditional methods based on light microscopy, we proposed a spectral and morphologic method based on hyperspectral blood images. We applied mathematical morphology-based methods to extract spatial information and supervised method is employed for spectral analysis. Experimental results show that white blood cells could be segmented and classified into five types with an overall accuracy of more than 90%. Moreover, the experiments including spectral features reached higher accuracy than the spatial-only cases, with a maximum improvement of nearly 20%. By combing both spatial and spectral features, the proposed method provides higher classification accuracy than traditional methods.

  12. Measurements of blood flow and blood concentration change using laser speckle in fiber illumination and its application to estimation of stress condition

    Science.gov (United States)

    Yokoi, Naomichi; Shinohara, Tomomi; Funamizu, Hideki; Kyoso, Masaki; Shimatani, Yuichi; Yuasa, Tomonori; Aizu, Yoshihisa

    2016-11-01

    Speckle imaging method is useful for monitoring of blood flow in living bodies. We have proposed so far the method for simultaneous imaging of blood flow and blood concentration change using laser speckle patterns at two wavelengths. However, our conventional measurement system has difficulty in adjusting the illuminating optical axis of two laser sources. Therefore, we introduce a novel arrangement using a coaxial fiber illumination in the detection of speckle patterns in two wavelengths. By this arrangement, the blood flow can be stably analyzed with a frame rate using an estimation parameter proposed by the authors based on the spatial contrast of speckle patterns. This parameter is useful for estimating an autonomic nervous function which reflects stress conditions caused by tension and excitement. In this study, we present measurements of the blood flow and blood concentration change in the fiber illumination, and its application to estimation of stress condition.

  13. Evaluation of automated blood pressure measurements during exercise testing.

    Science.gov (United States)

    Hossack, K F; Gross, B W; Ritterman, J B; Kusumi, F; Bruce, R A

    1982-11-01

    Measurements of systolic (SBP) and diastolic (DBP) blood pressure were made at rest and during symptom-limited exercise with an automated blood pressure measuring device (EBPM). Comparisons were made between the EBPM readings and those made with mercury manometer. Correlations were high (SBP r = 0.92, DBP r = 0.80) when readings were made in the same arm, but were less satisfactory when the cuffs were on different arms (SBP r = 0.80, DBP r = 0.46). The correlation between two mercury manometer readings was SBP r = 0.90, and DBP r = 0.75. Comparison between EBPM and intra-arterial measurements were similar (SBP r = 0.74, DBP r = 0.79) to comparison between mercury manometer and intra-arterial measurements (SBP r = 0.81, DBP r = 0.61). The EBPM detected SBP at consistently higher levels than did physicians, which may be an advantage in the noisy environment of an exercise test. There was a definite tendency for physicians to record blood pressure to the nearest 10 mm Hg, whereas the frequency distribution curve for EBPM measurements was smoother. The EBPM operated satisfactorily at rest and during maximal exercise and gave as reliable measurements as a physician using a mercury manometer and, in the small number of available cases, detected exertional hypotension more often than the physician.

  14. Microleakage and its measurement methods

    Directory of Open Access Journals (Sweden)

    Siyadat H

    2002-07-01

    Full Text Available Microkeakage is one of the most important factors in restoration longevity. Microleakage can"nlead to recurrent caries, marginal fracture, marginal discoloration and tooth sensitivity. Several methods"nhave been used for in-vitro measurement of microleakage. The present study is a review of the articles,"nfrom 1967 to 1999, which have been present in Medline.

  15. Development of a Phantom Tissue for Blood Perfusion Measurements and Noninvasive Blood Perfusion Estimation in Living Tissue

    OpenAIRE

    Mudaliar, Ashvinikumar

    2007-01-01

    A convenient method for testing and calibrating surface perfusion sensors has been developed. A phantom tissue model is used to mimic the non-directional blood flow of tissue perfusion. A computational fluid dynamics (CFD) model was constructed in Fluent to design the phantom tissue and validate the experimental results. The phantom perfusion system was used with a perfusion sensor based on the clearance of thermal energy. A heat flux gage measures the heat flux response of tissue whe...

  16. Pulse measurement apparatus and method

    Science.gov (United States)

    Marciante, John R.; Donaldson, William R.; Roides, Richard G.

    2011-10-25

    An embodiment of the invention is directed to a pulse measuring system that measures a characteristic of an input pulse under test, particularly the pulse shape of a single-shot, nano-second duration, high shape-contrast optical or electrical pulse. An exemplary system includes a multi-stage, passive pulse replicator, wherein each successive stage introduces a fixed time delay to the input pulse under test, a repetitively-gated electronic sampling apparatus that acquires the pulse train including an entire waveform of each replica pulse, a processor that temporally aligns the replicated pulses, and an averager that temporally averages the replicated pulses to generate the pulse shape of the pulse under test. An embodiment of the invention is directed to a method for measuring an optical or an electrical pulse shape. The method includes the steps of passively replicating the pulse under test with a known time delay, temporally stacking the pulses, and temporally averaging the stacked pulses. An embodiment of the invention is directed to a method for increasing the dynamic range of a pulse measurement by a repetitively-gated electronic sampling device having a rated dynamic range capability, beyond the rated dynamic range of the sampling device; e.g., enhancing the dynamic range of an oscilloscope. The embodied technique can improve the SNR from about 300:1 to 1000:1. A dynamic range enhancement of four to seven bits may be achieved.

  17. Nonstandard Methods in Measure Theory

    Directory of Open Access Journals (Sweden)

    Grigore Ciurea

    2014-01-01

    to the study of the extension of vector measures. Applications of our results lead to simple new proofs for theorems of classical measure theory. The novelty lies in the use of the principle of extension by continuity (for which we give a nonstandard proof to obtain in an unified way some notable theorems which have been obtained by Fox, Brooks, Ohba, Diestel, and others. The methods of proof are quite different from those used by previous authors, and most of them are realized by means of nonstandard analysis.

  18. Direct detection of red blood cell fragments: a new flow cytometric method to evaluate hemolysis in blood pumps.

    Science.gov (United States)

    Linneweber, J; Chow, T W; Takano, T; Maeda, T; Nonaka, K; Schulte-Eistrup, S; Kawahito, S; Elert, O; Moake, J L; Nosé, Y

    2001-01-01

    Pump induced hemolysis is presently evaluated by measuring plasma free hemoglobin (fHb). However, this method has disadvantages because quantification of fHb depends on hematocrit (HCT) and hemoglobin (Hb) levels. The aim of this work was to devise a hemoglobin independent method, capable of quantifying cell trauma directly by measuring the number of red blood cell (RBC) fragments. Whole blood flow cytometry was used to quantify circulating RBC fragments derived from a roller pump (Sarns, Inc. Model 2 M 6,002) and a centrifugal pump (Gyro C1E3, Kyocera Corp.). The pumps were tested in a mock circuit for 2 hr (5 L/min flow against 100 mm Hg pressure head). Red blood cell fragments were quantified by a phycoerythrin (PE) labeled glycophorin A antibody specific for erythrocytes. Red blood cell fragments were smaller than the intact RBC population and overlapped in size with the platelet population (based on forward- and side-light scattering measurements). For the roller pump, the values for RBC fragments increased from 1,090 +/- 260/microl at 0 min to 14,880 +/- 5,900/microl after 120 min. In contrast, using the centrifugal pump, there was little increase in RBC fragments (from 730 +/- 270/microl at 0 min to 1,400 +/- 840/microl after 120 min). Flow cytometry can be used for the rapid, sensitive, hemoglobin independent evaluation of pump induced RBC trauma.

  19. Spectrophotometric determination of total proteins in blood plasma: a comparative study among dye-binding methods

    OpenAIRE

    Dimas Augusto Morozin Zaia; Fábio Rangel Marques; Cássia Thaïs Bussamra Vieira Zaia

    2005-01-01

    A comparative study between the biuret method (standard method for total proteins) and spectrophotometric methods using dyes (Bradford, 3',3",5',5"-tetrabromophenolphthalein ethyl ester-TBPEE, and erythrosin-B) was carried out for the determination of total proteins in blood plasma from rats. Bradford method showed the highest sensitivity for proteins and biuret method showed the lowest. For all the methods, the absorbance for different proteins (BSA, casein, and egg albumin) was measured and...

  20. Ultrasonic Measurement of Fluid Viscosity for Blood Characterization

    Science.gov (United States)

    Nitta, Naotaka; Homma, Kazuhiro

    2005-06-01

    Although plaque rupture in arteriosclerosis is affected by not only its strength but also by hemodynamic factors, such as blood pressure and shear stress, in particular, the viscous coefficient which directly controls the magnitude of shear stress might be a risk factor in plaque rupture. Therefore, if the viscous coefficient can be assessed noninvasively, it can be a useful index for prediction of a plaque rupture and assessment of various diseases. In this work, an ultrasonic methodology to estimate the viscous coefficient was investigated by numerical simulation and flow-phantom experiment as the fundamental investigation for noninvasively assessing the viscous characteristics of blood. These results show that the proposed method is useful for estimating the kinematic viscosity coefficient in the viscous evaluation of blood.

  1. Blood-Pressure Measuring System Gives Accurate Graphic Output

    Science.gov (United States)

    1965-01-01

    The problem: To develop an instrument that will provide an external (indirect) measurement of arterial blood pressure in the form of an easily interpreted graphic trace that can be correlated with standard clinical blood-pressure measurements. From sphygmograms produced by conventional sphygmographs, it is very difficult to differentiate the systolic and diastolic blood-pressure pulses and to correlate these indices with the standard clinical values. It is nearly impossible to determine these indices when the subject is under physical or emotional stress. The solution: An electronic blood-pressure system, basically similar to conventional ausculatory sphygmomanometers, employing a standard occluding cuff, a gas-pressure source, and a gas-pressure regulator and valve. An electrical output transducer senses cuff pressure, and a microphone positioned on the brachial artery under the occluding cuff monitors the Korotkoff sounds from this artery. The output signals present the conventional systolic and diastolic indices in a clear, graphical display. The complete system also includes an electronic timer and cycle-control circuit.

  2. Integration of acoustic radiation force and optical imaging for blood plasma clot stiffness measurement.

    Science.gov (United States)

    Wang, Caroline W; Perez, Matthew J; Helmke, Brian P; Viola, Francesco; Lawrence, Michael B

    2015-01-01

    Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood's transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties.

  3. Improved technique for blood flow velocity measurement using Doppler effect

    Science.gov (United States)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  4. Laser optical method of visualizing cutaneous blood vessels and its applications in biometry and photomedicine

    Science.gov (United States)

    Asimov, M. M.; Asimov, R. M.; Rubinov, A. N.

    2011-05-01

    We propose and examine a new approach to visualizing a local network of cutaneous blood vessels using laser optical methods for applications in biometry and photomedicine. Various optical schemes of the formation of biometrical information on the architecture of blood vessels of skin tissue are analyzed. We developed an optical model of the interaction of the laser radiation with the biological tissue and a mathematical algorithm of processing of measurement results. We show that, in medicine, the visualization of blood vessels makes it possible to calculate and determine regions of disturbance of blood microcirculation and to control tissue hypoxia, as well as to maintain the local concentration of oxygen at a level necessary for the normal cellular metabolism. We propose noninvasive optical methods for modern photomedicine and biometry for diagnostics and elimination of tissue hypoxia and for personality identification and verification via the pattern of cutaneous blood vessels.

  5. Association between routine and standardized blood pressure measurements and left ventricular hypertrophy among patients on hemodialysis

    Directory of Open Access Journals (Sweden)

    Walsh Michael

    2010-06-01

    Full Text Available Abstract Background Left ventricular (LV hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. Methods This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month. Agreement was assessed using Lin's concordance correlation coefficient (CCC and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC. Results Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80 predictive power for LV hypertrophy. Conclusions A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.

  6. In vivo noninvasive measurement of preprandial and postprandial blood glucose using optical coherence tomography

    Science.gov (United States)

    Zhang, Ying; Zhang, Xiyang; Li, Zhifang; Li, Hui

    2016-10-01

    Blood glucose concentration measurement is essential for the diagnosis and treatment of diabetes. However, conventional glucose measurement methods are invasive and not suitable for real-time monitoring. This study demonstrated a noninvasive blood glucose measurement method using optical coherence tomography to image human lip in vivo. Optical coherence tomography (OCT) is a noninvasive and depth-resolved technique capable of acquiring tissue structure images in real time. Human lip has very thin skin and is full of blood vessels, which is appropriate for noninvasive glucose measurement. To verify the feasibility of OCT for glucose concentration monitoring, two groups of OCT imaging data were obtained from human lips of normal people. In one group, OCT images of lip were acquired from people on an empty stomach. In the other group, the same sites of lip were observed by OCT 2 hours after breakfast. Evident differences were found from two groups of OCT images that correspond to preprandial glucose and 2- hour postprandial glucose, respectively. The relationship between OCT image and blood glucose concentration was investigated. The result indicates that OCT possesses considerable prospects in terms of noninvasive blood glucose measurement.

  7. Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Swiontkowski, M.F.; Tepic, S.; Perren, S.M.; Moor, R.; Ganz, R.; Rahn, B.A.

    1986-01-01

    Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and /sup 85/Sr-labeled microspheres were made in an adult rabbit model. There was no correlation between the two methods for blood flow in the femoral condyles and the correlation between the two methods for blood flow in the femoral head does not achieve statistical significance. An LDF signal of 0.4 V was approximately equal to a microsphere measured flow rate of 0.4 ml blood/g bone/min. The strength of the correlation in the latter case may have been affected by (a) large arteriovenous shunts, (b) inadequate mixing of the microspheres with a left ventricular injection, and (c) insufficient numbers of microspheres present in the bone samples. When LDF was used to evaluate the effect of elevated intracapsular pressure on femoral head blood flow in skeletally mature rabbits, femoral head subchondral bone blood flow declined with increasing intracapsular pressure from a baseline value of 0.343 +/- 0.036 to a value of 0.127 +/- 0.27 at 120 cm of water pressure. The decline in femoral head blood flow was statistically significant at pressures of 40 cm of water or higher (p less than 0.001), and evaluation of sections of the proximal femora made from preterminal disulphine blue injections confirmed these findings. Intracapsular tamponade has an adverse effect on femoral head blood flow beginning well below central venous pressure and should be considered in the pathophysiology of posttraumatic and nontraumatic necrosis of the femoral head. Laser Doppler flowmetry was easy to use and appears to be a reproducible technique for evaluating femoral head blood flow, offering distinct advantages over the microsphere technique for measuring bone blood flow.

  8. Quantification of Cell-Free DNA in Red Blood Cell Units in Different Whole Blood Processing Methods

    Directory of Open Access Journals (Sweden)

    Andrew W. Shih

    2016-01-01

    Full Text Available Background. Whole blood donations in Canada are processed by either the red cell filtration (RCF or whole blood filtration (WBF methods, where leukoreduction is potentially delayed in WBF. Fresh WBF red blood cells (RBCs have been associated with increased in-hospital mortality after transfusion. Cell-free DNA (cfDNA is released by neutrophils prior to leukoreduction, degraded during RBC storage, and is associated with adverse patient outcomes. We explored cfDNA levels in RBCs prepared by RCF and WBF and different storage durations. Methods. Equal numbers of fresh (stored ≤14 days and older RBCs were sampled. cfDNA was quantified by spectrophotometry and PicoGreen. Separate regression models determined the association with processing method and storage duration and their interaction on cfDNA. Results. cfDNA in 120 RBC units (73 RCF, 47 WBF were measured. Using PicoGreen, WBF units overall had higher cfDNA than RCF units (p=0.0010; fresh WBF units had higher cfDNA than fresh RCF units (p=0.0093. Using spectrophotometry, fresh RBC units overall had higher cfDNA than older units (p=0.0031; fresh WBF RBCs had higher cfDNA than older RCF RBCs (p=0.024. Conclusion. Higher cfDNA in fresh WBF was observed compared to older RCF blood. Further study is required for association with patient outcomes.

  9. Evaluation of Two Different Methods for Hemoglobin Screening of Blood Donors to Use in Mobile Blood Collection Team

    Directory of Open Access Journals (Sweden)

    Soner Yilmaz

    2014-10-01

    Full Text Available AIM: The aim of the study is to compared two point-of care hemoglobin concentration measuring devices with laboratory measurements to determine their accuracy in mobile blood collection conditions. This two devices were the Pronto-7 (Masimo Corp., Irvine,CA pulse co-oximeter and HemoCue Hb 201+ uses spectrophotometric method. METHODS: Blood samples were collected from 152 individuals. The samples were tested for total hemoglobin measurement by three different methods: noninvaziv pulse co-oximeter device Pronto-7, finger-stick blood sample on an automated spectrophotometric device HemoCue and venous samples on an automated hemotology analyzer (reference device RESULTS: According to the venous samples (mean Hb value is 14.6 g/dl, the mean hemoglobin levels were detected slightly higher in the fingerstick samples (mean Hb value is 15.1 g/dl and slightly lower in the pulse co-oximetry (mean Hb value is 14.1 g/dl. The sensivity of HemoCue, Pronto-7 was 97.7%, 81.6% and their specifity was 31.2% and %43.7, respectively. The positive predictive values (PPV of HemoCue and Pronto-7 were high (92.3% and 92.5%, respectively but both of their negative predictive values (NPV were low (62.5% and 21.8%, respectively. Of blood donors, 88.4% (138/152 percent were correctly classified with HemoCue and 78.2% were with Pronto-7. COCLUSION: Taking automated laboratory hemoglobin measurement as a reference, Pronto-7 gave lower readings for Hb value and was less accurate than the Hemo-Cue system [TAF Prev Med Bull 2014; 13(5.000: 391-394

  10. Blood pressure measurement: lessons learned from our ancestors.

    Science.gov (United States)

    Karamanou, Marianna; Papaioannou, Theodore G; Tsoucalas, Gregory; Tousoulis, Dimitris; Stefanadis, Christodoulos; Androutsos, George

    2015-01-01

    The profound observations of William Harvey (1578-1657), in blood circulation and the progress of physical science laid the foundation for the development of the Iatrophysical School that contributed to the evolution of clinical sphygmomanometry. The pioneer work of Reverend Stephen Hales (1677-1761) demonstrated the dynamics of the vascular system. One century later the French physician Jean-Léonard-Marie Poiseuille (1797-1867) invented a U-tube mercury manometer and in 1860 the physiologist Etienne- Jules Marey (1830-1904) devised the first portable sphygmograph for recording the pulse wave. The non-invasive techniques of blood pressure measurement were completed by Scipione Riva-Rocci (1896-1937) sphygmomanometer and the description of "Korotkov sounds" by the Russian surgeon Nikolai- Sergeyevich Korotkov (1874-1920).

  11. Four-Parameter white blood cell differential counting based on light scattering measurements

    NARCIS (Netherlands)

    Terstappen, L.W.M.M.; Grooth, de B.G.; Visscher, K.; Kouterik, F.A.; Greve, J.

    1988-01-01

    Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinephilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped

  12. Prediction methods for blood glucose concentration design, use and evaluation

    CERN Document Server

    Jørgensen, John; Renard, Eric; Re, Luigi

    2016-01-01

    This book tackles the problem of overshoot and undershoot in blood glucose levels caused by delay in the effects of carbohydrate consumption and insulin administration. The ideas presented here will be very important in maintaining the welfare of insulin-dependent diabetics and avoiding the damaging effects of unpredicted swings in blood glucose – accurate prediction enables the implementation of counter-measures. The glucose prediction algorithms described are also a key and critical ingredient of automated insulin delivery systems, the so-called “artificial pancreas”. The authors address the topic of blood-glucose prediction from medical, scientific and technological points of view. Simulation studies are utilized for complementary analysis but the primary focus of this book is on real applications, using clinical data from diabetic subjects. The text details the current state of the art by surveying prediction algorithms, and then moves beyond it with the most recent advances in data-based modeling o...

  13. Laser Doppler flowmetry is valid for measurement of cerebral blood flow autoregulation lower limit in rats

    DEFF Research Database (Denmark)

    Tonnesen, Jan; Pryds, Anders; Larsen, Erik Hviid

    2005-01-01

    Laser Doppler flowmetry (LDF) is a recent technique that is increasingly being used to monitor relative changes in cerebral blood flow whereas the intra-arterial 133xenon injection technique is a well-established method for repeated absolute measurements of cerebral blood flow. The aim of this st...... CO2 challenge. Haemodilution influences the two methods differently causing relative overestimation of blood flow by the laser Doppler technique compared to the 133xenon method....... of this study was to validate LDF for assessment of cerebral autoregulation and CO2 reactivity with the 133xenon injection technique as the gold standard. Simultaneous measurements of cerebral blood flow (CBF) were collected by LDF (CBFLDF) and the 133xenon method (CBFXe) while (1) cerebral autoregulation...... was challenged by controlled systemic haemorrhage, or (2) cerebral blood flow was varied by manipulating the arterial partial pressure of CO2 (Pa,CO2). LDF slightly overestimated CBF under conditions of haemorrhagic shock and haemodilution caused by controlled haemorrhage (paired t test, P

  14. An assessment of various blood collection and transfer methods used for malaria rapid diagnostic tests

    Directory of Open Access Journals (Sweden)

    Baik Fred

    2007-11-01

    Full Text Available Abstract Background Four blood collection and transfer devices commonly used for malaria rapid diagnostic tests (RDTs were assessed for their consistency, accuracy and ease of use in the hands of laboratory technicians and village health workers. Methods Laboratory technicians and village health workers collected blood from a finger prick using each device in random order, and deposited the blood either on filter paper or into a suitable casette-type RDT. Consistency and accuracy of volume delivered was determined by comparing the measurements of the resulting blood spots/heights with the measurements of laboratory-prepared pipetted standard volumes. The effect of varying blood volumes on RDT sensitivity and ease of use was also observed. Results There was high variability in blood volume collected by the devices, with the straw and the loop, the most preferred devices, usually transferring volumes greater than intended, while the glass capillary tube and the plastic pipette transferring less volume than intended or none at all. Varying the blood volume delivered to RDTs indicated that this variation is critical to RDT sensitivity only when the transferred volume is very low. Conclusion None of the blood transfer devices assessed performed consistently well. Adequate training on their use is clearly necessary, with more development efforts for improved designs to be used by remote health workers, in mind.

  15. Extraction of human genomic DNA from whole blood using a magnetic microsphere method.

    Science.gov (United States)

    Gong, Rui; Li, Shengying

    2014-01-01

    With the rapid development of molecular biology and the life sciences, magnetic extraction is a simple, automatic, and highly efficient method for separating biological molecules, performing immunoassays, and other applications. Human blood is an ideal source of human genomic DNA. Extracting genomic DNA by traditional methods is time-consuming, and phenol and chloroform are toxic reagents that endanger health. Therefore, it is necessary to find a more convenient and efficient method for obtaining human genomic DNA. In this study, we developed urea-formaldehyde resin magnetic microspheres and magnetic silica microspheres for extraction of human genomic DNA. First, a magnetic microsphere suspension was prepared and used to extract genomic DNA from fresh whole blood, frozen blood, dried blood, and trace blood. Second, DNA content and purity were measured by agarose electrophoresis and ultraviolet spectrophotometry. The human genomic DNA extracted from whole blood was then subjected to polymerase chain reaction analysis to further confirm its quality. The results of this study lay a good foundation for future research and development of a high-throughput and rapid extraction method for extracting genomic DNA from various types of blood samples.

  16. Rotating permanent magnet excitation for blood flow measurement.

    Science.gov (United States)

    Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S

    2015-11-01

    A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

  17. Quantitative absorption cytometry for measuring red blood cell hemoglobin mass and volume.

    Science.gov (United States)

    Schonbrun, Ethan; Malka, Roy; Di Caprio, Giuseppe; Schaak, Diane; Higgins, John M

    2014-04-01

    We present an optical system, called the quantitative absorption cytometer (QAC), to measure the volume and hemoglobin mass of red blood cells flowing through a microfluidic channel. In contrast to clinical hematology analyzers, where cells are sphered in order for both volume and hemoglobin to be measured accurately, the QAC measures cells in their normal physiological shape. Human red blood cells are suspended in a refractive index-matching absorbing buffer, driven through a microfluidic channel, and imaged using a transmission light microscope onto a color camera. A red and a blue LED illuminate cells and images at each color are used to independently retrieve cell volume and hemoglobin mass. This system shows good agreement with red blood cell indices retrieved by a clinical hematology analyzer and in fact measures a smaller coefficient of variation of hemoglobin concentration. In addition to cell indices, the QAC returns height and mass maps of each measured cell. These quantitative images are valuable for analyzing the detailed morphology of individual cells as well as statistical outliers found in the data. We also measured red blood cells in hypertonic and hypotonic buffers to quantify the correlation between volume and hemoglobin mass under osmotic stress. Because this method is invariant to cell shape, even extremely nonspherical cells in hypertonic buffers can be measured accurately.

  18. Common Genetic Polymorphisms Influence Blood Biomarker Measurements in COPD.

    Science.gov (United States)

    Sun, Wei; Kechris, Katerina; Jacobson, Sean; Drummond, M Bradley; Hawkins, Gregory A; Yang, Jenny; Chen, Ting-Huei; Quibrera, Pedro Miguel; Anderson, Wayne; Barr, R Graham; Basta, Patricia V; Bleecker, Eugene R; Beaty, Terri; Casaburi, Richard; Castaldi, Peter; Cho, Michael H; Comellas, Alejandro; Crapo, James D; Criner, Gerard; Demeo, Dawn; Christenson, Stephanie A; Couper, David J; Curtis, Jeffrey L; Doerschuk, Claire M; Freeman, Christine M; Gouskova, Natalia A; Han, MeiLan K; Hanania, Nicola A; Hansel, Nadia N; Hersh, Craig P; Hoffman, Eric A; Kaner, Robert J; Kanner, Richard E; Kleerup, Eric C; Lutz, Sharon; Martinez, Fernando J; Meyers, Deborah A; Peters, Stephen P; Regan, Elizabeth A; Rennard, Stephen I; Scholand, Mary Beth; Silverman, Edwin K; Woodruff, Prescott G; O'Neal, Wanda K; Bowler, Russell P

    2016-08-01

    Implementing precision medicine for complex diseases such as chronic obstructive lung disease (COPD) will require extensive use of biomarkers and an in-depth understanding of how genetic, epigenetic, and environmental variations contribute to phenotypic diversity and disease progression. A meta-analysis from two large cohorts of current and former smokers with and without COPD [SPIROMICS (N = 750); COPDGene (N = 590)] was used to identify single nucleotide polymorphisms (SNPs) associated with measurement of 88 blood proteins (protein quantitative trait loci; pQTLs). PQTLs consistently replicated between the two cohorts. Features of pQTLs were compared to previously reported expression QTLs (eQTLs). Inference of causal relations of pQTL genotypes, biomarker measurements, and four clinical COPD phenotypes (airflow obstruction, emphysema, exacerbation history, and chronic bronchitis) were explored using conditional independence tests. We identified 527 highly significant (p 10% of measured variation in 13 protein biomarkers, with a single SNP (rs7041; p = 10-392) explaining 71%-75% of the measured variation in vitamin D binding protein (gene = GC). Some of these pQTLs [e.g., pQTLs for VDBP, sRAGE (gene = AGER), surfactant protein D (gene = SFTPD), and TNFRSF10C] have been previously associated with COPD phenotypes. Most pQTLs were local (cis), but distant (trans) pQTL SNPs in the ABO blood group locus were the top pQTL SNPs for five proteins. The inclusion of pQTL SNPs improved the clinical predictive value for the established association of sRAGE and emphysema, and the explanation of variance (R2) for emphysema improved from 0.3 to 0.4 when the pQTL SNP was included in the model along with clinical covariates. Causal modeling provided insight into specific pQTL-disease relationships for airflow obstruction and emphysema. In conclusion, given the frequency of highly significant local pQTLs, the large amount of variance potentially explained by pQTL, and the

  19. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    DEFF Research Database (Denmark)

    Thomsen, H; Steffensen, E; Larsson, Elna-Marie

    2012-01-01

    technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose: To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC......, and glioblastomas. Results: rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r ¼ 0.60) and to the cerebellum (r ¼ 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated......-MRI using two different regions for normalization and two different measurement approaches. Material and Methods: Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and r...

  20. Frequency of Blood Pressure Measuring According to the Degree of Working Population Education in Canton Sarajevo

    Science.gov (United States)

    Brankovic, Suada; Pilav, Aida; Macak-Hadziomerovic, Amra; Rama, Admir; Segalo, Mersa

    2013-01-01

    Introduction: Hypertension (high blood pressure) is one of the most widely spread modern diseases and one of the leading risk factors for heart and blood vessel diseases, particularly stroke and coronary heart disease. The prevalence of hypertension is about 25% in adults. Many studies show that blood pressure tends to have lower values among people with higher education levels. Goal: To determine the frequency of measurement and control of blood pressure in relation to the level of education of the active working population of the Sarajevo Canton. Material and methods: The study was conducted on 443 subjects randomly selected from the categories of the active working population of the Sarajevo Canton. The study was conducted at the Center for Heart, Clinical Center University of Sarajevo University through the project “Prevention of risk factors for cardiovascular disease in the active working population of the Sarajevo Canton”. Respondents were at age in range from 18-65 years, who have voluntarily joined the study. Results: Of 443 (100%) of the respondents 153 (34.5%) were males compared to females whose participation in the sample was 290 (65.5%). Regarding the structure of respondents, the majority of them 213 (48.1%) graduated faculty, 142 (32, 1%) graduated secondary vocational schools and 66 (14.9%) with a higher degree, with the lowest number with completed grammar school (1.4%) and secondary school (0.5%). Blood pressure never measure 16 (3.6%) of respondents, which is not insignificant number, more than 5 years ago 23 (5.2%), within last 1-5 years 90 (20.3%), in the past 12 months 88 (19.9% ) and 226 (51%) measured the blood pressure in the past 6 months. Blood pressure never controlled 4.33% of respondents with secondary or higher education and 2.82% of the respondents with university education. Chi-square test showed a difference between education and the prevalence of blood pressure, χ2=7.812; DF=8; p=0.045. Conclusion: Monitoring of blood

  1. Evaluation of a method for determination of the subcutaneous blood flow in the forefoot continuously over 24 h

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Bülow, J

    1984-01-01

    A method is presented which allows for continuous registration of forefoot blood flow over 24 h. Blood flow was estimated by the radioactive Xenon washout method and a portable CdTe detector system was used to measure the tracer disappearance rate. Since the semiconductor detector is placed very...

  2. Comparison of noninvasive blood pressure measurement techniques via the coccygeal artery in anesthetized cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Sadler, Ryan A; Hall, Natalie H; Kass, Philip H; Citino, Scott B

    2013-12-01

    Two indirect blood pressure measurement techniques, Doppler (DOP) sphygmomanometry and oscillometry, applied at the ventral coccygeal artery were compared with simultaneous direct blood pressure measurements at the dorsal pedal artery in 10 anesthetized, captive cheetahs (Acinonyx jubatus). The DOP method was moderately accurate, with relatively little bias (mean difference 3.8 mmHg) and 88.6% of the DOP systolic arterial pressure measurements being within 10 mmHg of the direct systolic arterial measurement. With the oscillometric (OM) method, 89.2% of the mean arterial pressure measurements were within 10 mmHg of the direct measurement and had the least bias (mean difference 2.3 mmHg), 80.7% of the systolic measurements were within 10 mmHg of the direct measurement and had the second least bias (mean difference 2.3 mmHg), and 59% of the diastolic measurements were within 10 mmHg of the direct measurement and had significant bias (mean difference 7.3 mmHg). However, DOP showed relatively poor precision (SD 11.2 mmHg) compared with OM systolic (SD 8.0 mmHg), diastolic (SD 8.6 mmHg), and mean (SD 5.7 mmHg). Both techniques showed a linear relationship with the direct technique measurements over a wide range of blood pressures. The DOP method tended to underestimate systolic measurements below 160 mmHg and overestimate systolic measurements above 160 mmHg. The OM method tended to underestimate mean pressures below 160 mm Hg, overestimate mean pressures above 160 mmHg, underestimate systolic pressures below 170 mmHg, overestimate systolic pressures above 170 mmHg, and underestimate diastolic pressures throughout the measured blood pressure range. Indirect blood pressure measurement using the ventral coccygeal artery, particularly when using an OM device for mean and systolic arterial pressure, may be useful in the clinical assessment of cheetahs when monitoring trends over time, but caution should be taken when interpreting individual values.

  3. Context-aware patient guidance during blood pressure self-measurement

    DEFF Research Database (Denmark)

    Sandager, Puk; Lindahl, Camilla; Schlütter, Jacob Mørup

    2013-01-01

    The importance of accurate measurement of blood pressure in the screening and management of hypertension during pregnancy is well established. Blood pressure levels can be measured manually by healthcare staff or by using a blood pressure self-measurement device, either at home or in the clinic...... the blood pressure self-measurement process. Preliminary results indicate that such active and context-aware guidance leads to more reliable measurements by inhibiting non-adherent patient behavior...

  4. Automated Methods Of Corrosion Measurements

    DEFF Research Database (Denmark)

    Bech-Nielsen, Gregers; Andersen, Jens Enevold Thaulov; Reeve, John Ch

    1997-01-01

    The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell.......The chapter describes the following automated measurements: Corrosion Measurements by Titration, Imaging Corrosion by Scanning Probe Microscopy, Critical Pitting Temperature and Application of the Electrochemical Hydrogen Permeation Cell....

  5. Application of Servqual evaluation method in measuring service quality of blood collection%Servqual评价法在门诊采血服务质量评价中的调查

    Institute of Scientific and Technical Information of China (English)

    郭惠子; 纪代红

    2015-01-01

    Objective Investigating the present situation of nursing service in tertiary general hospital blood specimen col-lection to find out the key factors affecting the quality of service. Methods The Servqual scale was used among 300 patients with blood collecting. Results The perceived service quality score of every hospital was negative,the difference of Tangible、Reliability、Responsiveness、Assurance、Empathy of different hospitals was statistically significant (P<0.05).And the effect of gender and payment mode of medical expenses for perceived service quality were statistically significant(P<0.05). Conclu-sions The service quality of blood specimen collection remains to be further improved,Servqual scale can objectively and ef-fectively analyze the key problem of nursing service quality.%目的:应用Servqual评价法调查三级甲等综合医院门诊血液标本采集服务质量现状,探讨影响感知服务质量的因素。方法应用基于Servqual评价法的服务质量测评量表对300例门诊血液标本采集患者进行调查。结果各三级甲等医院的感知服务质量均为负值,不同医院感知服务质量在有形性、可靠性、响应性、保证性、移情性五个维度上的差异有统计学意义(P<0.05)。比较性别和医疗费用支付情况对感知服务质量的影响,差异有统计学意义(P<0.05)。结论门诊采血服务质量有待进一步提高,Servqual量表能够客观、有效地分析出影响护理服务质量的关键问题,对持续性改进服务质量具有重要意义。

  6. Portal blood flow volume measurement in schistosomal patients: evaluation of Doppler ultrasonography reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; Shigueoka, David Carlos; D' Ippolito, Giuseppe [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem]. E-mail: ar.leao@uol.com.br; Colleoni, Ramiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Escola Paulista de Medicina. Dept. de Gastroenterologia

    2008-09-15

    Objective: To evaluate the reproducibility of Doppler ultrasonography in the measurement of portal blood flow volume in schistosomal patients. Materials and methods: Prospective, transversal, observational and self-paired study evaluating 21 patients with hepatosplenic schistosomiasis submitted to Doppler ultrasonography performed by three independent observers for measurement of portal blood flow. Pairwise interobserver agreement was calculated by means of the intraclass correlation coefficient, paired t-test and Pearson's correlation coefficient. Results: Interobserver agreement was excellent. Intraclass correlation ranged from 80.6% to 93.0% (IC at 95% [65.3% ; 95.8%]), with the Pearson's correlation coefficient ranging between 81.6% and 92.7% with no statistically significant interobserver difference regarding the mean portal blood flow volume measured by Doppler ultrasonography (p = 0.954 / 0.758 / 0.749). Conclusion: Doppler ultrasonography has demonstrated to be a reliable method for measuring the portal blood flow volume in patients with portal hypertension secondary to schistosomiasis, with a good interobserver agreement. (author)

  7. Comparison of near-infrared spectroscopy with CT cerebral blood flow measurements in newborn piglets

    Science.gov (United States)

    Brown, Derek W.; Picot, Paul A.; Springett, Roger; Delpy, David T.; Lee, Ting-Yim

    2001-05-01

    Severely premature infants are often at high risk of cerebral hemorrhage or ischemic injury due to their inability to properly regulate blood flow to the brain. If blood flow is too high, the infant is at risk of cerebral hemorrhage, while too little blood flow can result in ischemic injury. The purpose of this research is to design and develop a means of non-invasively measuring cerebral blood flow (CBF) with near infrared spectroscopy (NIRS). Such a device would greatly aid the diagnosis and monitoring of afflicted infants. Previous attempts to measure CBF with NIRS have achieved limited success. In this study we acquired high signal-to-noise NIR spectrum from 600 to 980 nm with a cooled CCD spectrometer. This spectrometer enables the differential path length factor (DPF) to be estimated with accuracy using a second derivative technique described by Matcher et al. The validity of our new approach is determined via direct comparison with a previously validated computed tomography (CT) method. Three newborn piglets were studied. CBF measurements were performed at various partial arterial CO2 tensions (PaCO2) using both the NIRS and CT methods. The results of the two methods correlate well with a relationship of CBFCT equals -4.30 + 1.05 CBFNIRS (r2 equals 0.96).

  8. Measurement of local cerebral blood flow with (/sup 14/C)iodoantipyrine in the mouse

    Energy Technology Data Exchange (ETDEWEB)

    Jay, T.M.; Lucignani, G.; Crane, A.M.; Jehle, J.; Sokoloff, L.

    1988-02-01

    Local cerebral blood flow was measured in the mouse by means of the (/sup 14/C)iodoantipyrine method. This method has been previously used in the monkey, dog, cat, and rat, but its application to small mammals such as the mouse requires special attention to potential sources of error. The small size of the mouse brain requires special attention to the rapid removal and freezing of the brain to minimize effects of postmortem diffusion of tracer in the tissue. Because of the relatively low diameter/length ratios of the catheters needed for arterial sampling in small animals, substantial errors can occur in the determination of the time course of the (/sup 14/C)iodoantipyrine concentration in the arterial blood unless corrections for lag time and dead space washout in the catheter are properly applied. Local cerebral blood flow was measured in seven awake mice with appropriate care to minimize these sources of error. The values were found to vary from 48 ml/100 g/min in the corpus callosum to 198 ml/100 g/min in the inferior colliculus. The results demonstrate that the (/sup 14/C)iodoantipyrine method can be used to measure local cerebral blood flow in the mouse and that the values in that species are, in general, somewhat higher than those in the rat.

  9. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  10. Quantitative measurement of cerebral blood flow on patients with early syphilis

    Institute of Scientific and Technical Information of China (English)

    ZHONG Ji-Jun; WU Jin-Chang; YANG Yi; TANG Jun; LIU Zeng-Li; SHI Xin

    2005-01-01

    To study quantitative change of cerebral blood flow (CBF) on patients with early syphilis, we have established a method on absolute measurement of rCBF by using SPECT with Ethyl Cysteinate Dimmer (ECD) as imaging agent, and the method was applied to measure rCBF on patients with early syphilis. The rCBF values measured by this method are highly consistent with the values measured by other classical methods such as SPECT (123I-IMP) and PET (15O-H2O). The rCBF values for early syphilis patients and the normal control show some statistical differences.A routine quantitative absolute measurement of rCBF featured with simple procedures is therefore on the way of maturation.

  11. Ultrasound modulated light blood flow measurement using intensity autocorrelation function: a Monte-Carlo simulation

    Science.gov (United States)

    Tsalach, A.; Metzger, Y.; Breskin, I.; Zeitak, R.; Shechter, R.

    2014-03-01

    Development of techniques for continuous measurement of regional blood flow, and in particular cerebral blood flow (CBF), is essential for monitoring critical care patients. Recently, a novel technique, based on ultrasound modulation of light was developed for non-invasive, continuous CBF monitoring (termed ultrasound-tagged light (UTL or UT-NIRS)), and shown to correlate with readings of 133 Xe SPECT1 and laser Doppler2. Coherent light is introduced into the tissue concurrently with an Ultrasound (US) field. Displacement of scattering centers within the sampled volume induced by Brownian motion, blood flow and the US field affects the photons' temporal correlation. Hence, the temporal fluctuations of the obtained speckle pattern provide dynamic information about the blood flow. We developed a comprehensive simulation, combining the effects of Brownian motion, US and flow on the obtained speckle pattern. Photons trajectories within the tissue are generated using a Monte-Carlo based model. Then, the temporal changes in the optical path due to displacement of scattering centers are determined, and the corresponding interference pattern over time is derived. Finally, the light intensity autocorrelation function of a single speckle is calculated, from which the tissue decorrelation time is determined. The simulation's results are compared with in-vitro experiments, using a digital correlator, demonstrating decorrelation time prediction within the 95% confidence interval. This model may assist in the development of optical based methods for blood flow measurements and particularly, in methods using the acousto-optic effect.

  12. Applicability of available methods for incidence estimation among blood donors

    Institute of Scientific and Technical Information of China (English)

    Shtmian Zou; Edward P.Notari IV; Roger Y.Dodd

    2010-01-01

    @@ Abstract Incidence rates of major transfusion transmissible viral infections have been estimated threugh widely used sereconversion approaches and recently developed methods.A quality database for blood donors and donations with the capacity to track donation history of each donor is the basis for incidence estimation and many other epidemiological studies.Depending on available data,difierent ways have been used to determine incidence rates based on conversion from uninfected to infected status among repeat donors.

  13. [Measurement of trace elements in blood serum by atomic absorption spectroscopy with electrothermal atomization].

    Science.gov (United States)

    Rogul'skiĭ, Iu V; Danil'chenko, S N; Lushpa, A P; Sukhodub, L F

    1997-09-01

    Describes a method for measuring trace elements Cr, Mn, Co, Fe, Cu, Zn, and Mo in the blood serum using non-flame atomization (KAC 120.1 complex). Optimal conditions for preparing the samples were defined, temperature regimens for analysis of each element selected, and original software permitting automated assays created. The method permits analysis making use of the minimal samples: 0.1 ml per 10 parallel measurements, which is 100 times less than needed for atomic absorption spectroscopy with flame atomization of liquid samples. Metrological characteristics of the method are assessed.

  14. [Instrumentation for blood pressure measurements: historical aspects, concepts and sources of error].

    Science.gov (United States)

    de Araujo, T L; Arcuri, E A; Martins, E

    1998-04-01

    According to the International Council of Nurses the measurement of blood pressure is the procedure most performed by nurses in all the world. The aim of this study is to analyse the polemical aspects of instruments used in blood pressure measurement. Considering the analyses of the literature and the American Heart Association Recommendations, the main source of errors when measuring blood pressure are discussed.

  15. Blood doping by cobalt. Should we measure cobalt in athletes?

    Directory of Open Access Journals (Sweden)

    Guidi Gian

    2006-07-01

    Full Text Available Abstract Background Blood doping is commonplace in competitive athletes who seek to enhance their aerobic performances through illicit techniques. Presentation of the hypothesis Cobalt, a naturally-occurring element with properties similar to those of iron and nickel, induces a marked and stable polycythemic response through a more efficient transcription of the erythropoietin gene. Testing the hypothesis Although little information is available so far on cobalt metabolism, reference value ranges or supplementation in athletes, there is emerging evidence that cobalt is used as a supplement and increased serum concentrations are occasionally observed in athletes. Therefore, given the athlete's connatural inclination to experiment with innovative, unfair and potentially unhealthy doping techniques, cobalt administration might soon become the most suited complement or surrogate for erythropoiesis-stimulating substances. Nevertheless, cobalt administration is not free from unsafe consequences, which involve toxic effects on heart, liver, kidney, thyroid and cancer promotion. Implications of the hypothesis Cobalt is easily purchasable, inexpensive and not currently comprehended within the World Anti-Doping Agency prohibited list. Moreover, available techniques for measuring whole blood, serum, plasma or urinary cobalt involve analytic approaches which are currently not practical for antidoping laboratories. Thus more research on cobalt metabolism in athletes is compelling, along with implementation of effective strategies to unmask this potentially deleterious doping practice

  16. A Study on Anthropometric Measurements, Blood Pressure, Blood Sugar and Food Intakes Among Different Social Status and Ethnicities

    Directory of Open Access Journals (Sweden)

    Jafarirad

    2016-09-01

    Full Text Available Background Metabolic syndrome is a disorder that increases the risk of cardiovascular disease and diabetes. Objectives The aim of the study was to evaluate some risk factors of the metabolic syndrome and food intakes among people who lived in Ahvaz City, Iran. Methods It was a filed study that was conducted on 211 subjects who participated in health exhibition. Socioeconomic status and ethnicity were asked by a general questionnaire. Weight, height, body mass index, waist circumference (WC and WC to hip circumference ratio (WHR were obtained. Blood sugar was measured by a glucometer. Systolic and diastolic blood pressures were obtained and dietary intakes were assessed by a brief instrument. Results There was a significant difference in weight, height, WC, WHR and systolic blood pressure among different jobs. Workers had more intakes of cake and sweets. Arab subjects had more intakes of bread and fishes and Persians more intakes of vegetables. Soda, chocolate and candy were more consumed by Kurd ethnicity. Conclusions Job may be accounted as an important effective socioeconomic factor related to metabolic syndrome risk factors; also different cultures due to different ethnicities may have an influence on lifestyle and dietary intakes.

  17. Retro-orbital blood acquisition facilitates circulating microRNA measurement in zebrafish with paracetamol hepatotoxicity.

    Science.gov (United States)

    Vliegenthart, Adriaan D B; Starkey Lewis, Philip; Tucker, Carl S; Del Pozo, Jorge; Rider, Sebastein; Antoine, Daniel J; Dubost, Valérie; Westphal, Magdalena; Moulin, Pierre; Bailey, Matthew A; Moggs, Jonathan G; Goldring, Chris E; Park, B Kevin; Dear, James W

    2014-06-01

    Paracetamol is the commonest cause of acute liver failure in the Western world and biomarkers are needed that report early hepatotoxicity. The liver-enriched microRNA (miRNA), miR-122, is a promising biomarker currently being qualified in humans. For biomarker development and drug toxicity screening, the zebrafish has advantages over rodents; however, blood acquisition in this model remains technically challenging. We developed a method for collecting blood from the adult zebrafish by retro-orbital (RO) bleeding and compared it to the commonly used lateral incision method. The RO technique was more reliable in terms of the blood yield and minimum amount per fish. This new RO technique was used in a zebrafish model of paracetamol toxicity. Paracetamol induced dose-dependent increases in liver cell necrosis, serum alanine transaminase activity, and mortality. In situ hybridization localized expression of miR-122 to the cytoplasm of zebrafish hepatocytes. After collection by RO bleeding, serum miR-122 could be measured and this miRNA was substantially increased by paracetamol 24 h after exposure, an increase that was prevented by delayed (3 h poststart of paracetamol exposure) treatment with acetylcysteine. In summary, collection of blood by RO bleeding facilitated measurement of miR-122 in a zebrafish model of paracetamol hepatotoxicity. The zebrafish represents a new species for measurement of circulating miRNA biomarkers that are translational and can bridge between fish and humans.

  18. Measurements of enlarged blood pump models using Laser Doppler Anemometer.

    Science.gov (United States)

    Chua, L P; Yu, S C; Leo, H L

    2000-01-01

    In an earlier study (Chua et al., 1998, 1999a), a 5:1 enlarged model of the Kyoto-NTN Magnetically Suspended Centrifugal Blood Pump (Akamatsu et al., 1995) with five different impeller blade profiles was designed and constructed. Their respective flow characteristics with respect to (1) the three different blade profile designs: forward, radial, and backward, (2) the number of blades used, and (3) the rotating speed were investigated. Among the five impeller designs, the results obtained suggested that impellers A and C designs should be adopted if higher head is required. Impellers A and C therefore were selected for the flow in between their blades to be measured using Laser Doppler Anemometer (LDA), so as to have a better understanding of the flow physics with respect to the design parameters.

  19. Worldwide trends in blood pressure from 1975 to 2015 : a pooled analysis of 1479 population-based measurement studies with 19.1 million participants

    OpenAIRE

    Zhou, Bin; Bentham, James; Di Cesare, Mariachiara; Bixby, Honor; Danaei, Goodarz; Cowan, Melanie J.; Paciorek, Christopher J.; Singh, Gitanjali; Hajifathalian, Kaveh; James E Bennett; Taddei, Cristina; Bilano, Ver; Carrillo-Larco, Rodrigo M.; Djalalinia, Shirin; Khatibzadeh, Shahab

    2017-01-01

    Background Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. Methods For this analysis, we pooled national, subnational, or community population-based studies that had measured ...

  20. Worldwide trends in blood pressure from 1975 to 2015: a pooled analysis of 1479 population-based measurement studies with 19.1 million participants

    OpenAIRE

    Zhou, Bin; Bentham, James; Di Cesare, Mariachiara; Bixby, Honor; Cowan, Melanie J.; Paciorek, Christopher J.; Singh, Gitanjali; Hajifathalian, Kaveh; James E Bennett; Taddei, Cristina; Bilano, Ver; Carrillo-Larco, Rodrigo M.; Khatibzadeh, Shahab; Lugero, Charles; Zhang, Wan Zhu

    2017-01-01

    Background Raised blood pressure is an important risk factor for cardiovascular diseases and chronic kidney disease. We estimated worldwide trends in mean systolic and mean diastolic blood pressure, and the prevalence of, and number of people with, raised blood pressure, defined as systolic blood pressure of 140 mm Hg or higher or diastolic blood pressure of 90 mm Hg or higher. Methods For this analysis, we pooled national, subnational, or community population-based studies that had measured ...

  1. A simplified method for determination of radioactive iron in whole-blood samples

    DEFF Research Database (Denmark)

    Bukhave, Klaus; Sørensen, Anne Dorthe; Hansen, M.

    2001-01-01

    For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method for simultane...... a sensitive method for studying the intestinal absorption of Fe-55 and Fe-59 in man and at the same time allows estimation of the amount of radioiron Located in the vascular compartment.......For studies on iron absorption in man radioisotopes represent an easy and simple tool. However, measurement of the orbital electron emitting radioiron, Fe-55, in blood is difficult and insufficiently described in the literature. The present study describes a relatively simple method...... for simultaneous determination of Fe-55 and Fe-59 in blood, using a dry-ashing procedure and recrystallization of the remaining iron. The detection Limit of the method permits measurements of 0.1 Bq/ml blood thus allowing detection of Less than 1% absorption from a 40 kBq dose, which is ethically acceptable...

  2. Dynamic Inertia Measurement Method Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Critically important inertia measurements are complex and expensive to obtain due to the extensive fixturing and custom instrumentation of conventional...

  3. [Equalization of whole-band signal's SNR in the blood components noninvasive measurement].

    Science.gov (United States)

    Li, Gang; Wang, Hui-quan; Zhang, Hao; Lin, Ling; Wu, Xiao-rong; Zhang, Bao-ju

    2012-02-01

    To fully extend the category of blood components that can be noninvasively measured by dynamic spectrum (DS) method and to increase its measuring precision, an overall consideration of light source, tissue absorption and sensor's sensitivity was made. Compensating the light source and adding the telecentric lens not only expand the spectral effective detecting range, but also balance the signal-to-noise ratio (SNR) of the photoelectric pulse in the whole band equalization. The integral SNR of DS signal was increased and the measurement bandwidth was expanded. The effectiveness of this method was validated by the quality evaluation criterion of DS data: the effective detecting range of visible DS was widened from 600-1 000 nm to 500-1 135 nm; the effective detecting range of near-infrared DS was widened from 900-1 100 nm to 900-1 700 nm. The results show that the design can create the condition for detection of new blood components noninvasively, and enhance the prediction accuracy of the blood components, for which noninvasive measuring using DS method has been achieved.

  4. Measuring blood delivery to solitary pulmonary nodules using perfusion magnetic resonance imaging

    Science.gov (United States)

    Zheng, Wei; Wang, Zhifeng; Shen, Li; Gao, Ling; Ford, James C.; Makedon, Fillia S.; Pearlman, Justin D.

    2006-03-01

    With perfusion magnetic resonance imaging (pMRI), perfusion describes the amount of blood passing through a block of tissue in a certain period of time. In pMRI, the tissue having more blood passing through will show higher intensity value as more contrast-labeled blood arrives. Perfusion reflects the delivery of essential nutrients to a block of tissue, and is an important parameter for the tissue status. Considering solitary pulmonary nodules (SPN), perfusion differences between malignant and benign nodules have been studied by different techniques. Much effort has been put into its characterization. In this paper, we proposed and implemented extraction of the SPN time intensity profile to measure blood delivery to solitary pulmonary nodules, describing their perfusion effects. In this method, a SPN time intensity profile is created based on intensity values of the solitary pulmonary nodule in lung pMRI images over time. This method has two steps: nodule tracking and profile clustering. Nodule tracking aligns the solitary pulmonary nodule in pMRI images taken at different time points, dealing with nodule movement resulted from breathing and body movement. Profile clustering implements segmentation of the nodule region and extraction of the time intensity profile of a solitary pulmonary nodule. SPN time intensity profiles reflect patterns of blood delivery to solitary pulmonary nodules, giving us a description of perfusion effect and indirect evidence of tumor angiogenesis. Analysis on SPN time intensity profiles will help the diagnosis of malignant nodules for early lung cancer detection.

  5. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C;

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...... that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein......., corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...

  6. The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

    Science.gov (United States)

    Laing, R. A.; Danisch, L. A.; Young, L. R.

    1975-01-01

    The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

  7. Cuff-less blood pressure measurement using pulse arrival time and a Kalman filter

    Science.gov (United States)

    Zhang, Qiang; Chen, Xianxiang; Fang, Zhen; Xue, Yongjiao; Zhan, Qingyuan; Yang, Ting; Xia, Shanhong

    2017-02-01

    The present study designs an algorithm to increase the accuracy of continuous blood pressure (BP) estimation. Pulse arrival time (PAT) has been widely used for continuous BP estimation. However, because of motion artifact and physiological activities, PAT-based methods are often troubled with low BP estimation accuracy. This paper used a signal quality modified Kalman filter to track blood pressure changes. A Kalman filter guarantees that BP estimation value is optimal in the sense of minimizing the mean square error. We propose a joint signal quality indice to adjust the measurement noise covariance, pushing the Kalman filter to weigh more heavily on measurements from cleaner data. Twenty 2 h physiological data segments selected from the MIMIC II database were used to evaluate the performance. Compared with straightforward use of the PAT-based linear regression model, the proposed model achieved higher measurement accuracy. Due to low computation complexity, the proposed algorithm can be easily transplanted into wearable sensor devices.

  8. Method for breast cancer diagnosis by phase spectrophotometry of human blood plasma

    Science.gov (United States)

    Mintser, Ozar P.; Oliinychenko, B. P.

    2012-01-01

    The possibility of breast cancer diagnostics by means of phase structure measurements of laser radiation transformed by human blood plasma samples. The theoretical fundamentals of polarization filtration method for direct phase shifts measurements of microscopic images are provided. The optical model of polycrystalline networks of blood plasma proteins is suggested. The results of investigating the interrelation between the values of statistical (statistical moments of the 1st-4th order), correlation (correlation area, asymmetry coefficient and autocorrelation function excess) and fractal (dispersion of logarithmic dependencies of power spectra) parameters are presented. They characterize the coordinate distributions of phase shifts between the orthogonal components of the amplitude in the points of laser images of blood plasma smears and pathological changes in the mammary gland tissue. The diagnostic criteria of breast cancer nascency are determined.

  9. Comparison of automated oscillometric versus auscultatory blood pressure measurement.

    Science.gov (United States)

    Landgraf, Johanna; Wishner, Stanley H; Kloner, Robert A

    2010-08-01

    Most clinical offices rely on automated oscillometric devices to measure blood pressure (BP), but the accuracy of this technique versus auscultatory determination using a mercury manometer is controversial. To assess the accuracy of automated oscillometric readings, BP was measured from the same site and cuff, in 337 consecutive patients seen in a routine cardiology office, using a simultaneous connection to an automated oscillometric and a mercury manometer technique. The mean systolic BP (133 +/- 20 mm Hg) and diastolic BP (72 +/- 11 mm Hg) were significantly greater using the mercury manometer than the automated oscillometric technique (systolic 131 +/- 18 and diastolic 70 +/- 12 mm Hg, p mercury manometer) in systolic BP were seen in 22% of all patients. Discrepancies in diastolic BP were seen in 20% of all patients. The mean of the discrepancy between the 2 techniques was 1.95 +/- 5 mm Hg (range 1 to 26) for systolic BP and 1.3 +/- 4 mm Hg (range 1 to 25) for diastolic BP. The discrepancies were greater in patients >65 years. In conclusion, the mercury manometer technique resulted in consistently greater BP values than oscillometric devices. These findings have important clinical implications, including the concept that patients whose BP appears to be under control using the oscillometric technique might not be at their goal BP and might have been undertreated.

  10. Numerical method of characteristics for one-dimensional blood flow

    CERN Document Server

    Acosta, Sebastian; Riviere, Beatrice; Penny, Daniel J; Rusin, Craig G

    2014-01-01

    Mathematical modeling at the level of the full cardiovascular system requires the numerical approximation of solutions to a one-dimensional nonlinear hyperbolic system describing flow in a single vessel. This model is often simulated by computationally intensive methods like finite elements and discontinuous Galerkin, while some recent applications require more efficient approaches (e.g. for real-time clinical decision support, phenomena occurring over multiple cardiac cycles, iterative solutions to optimization/inverse problems, and uncertainty quantification). Further, the high speed of pressure waves in blood vessels greatly restricts the time-step needed for stability in explicit schemes. We address both cost and stability by presenting an efficient and unconditionally stable method for approximating solutions to diagonal nonlinear hyperbolic systems. Theoretical analysis of the algorithm is given along with a comparison of our method to a discontinuous Galerkin implementation. Lastly, we demonstrate the ...

  11. Two-photon microscopy with double-circle trajectories for in vivo cerebral blood flow measurements

    Science.gov (United States)

    Landolt, Andrin; Obrist, Dominik; Wyss, Matthias; Barrett, Matthew; Langer, Dominik; Jolivet, Renaud; Soltysinski, Tomasz; Roesgen, Thomas; Weber, Bruno

    2013-05-01

    Scanning microscopes normally use trajectories which produce full-frame images of an object at a low frame rate. Time-resolved measurements are possible if scans along a single line are repeated at a high rate. In conjunction with fluorescence labeling techniques, in vivo recording of blood flow in single capillaries is possible. The present work investigates scanning with double-circle trajectories to measure blood flow simultaneously in several vessels of a capillary network. With the trajectory centered near a bifurcation, a double circle crosses each vessel twice, creating a sensing gate for passing dark red blood cells in fluorescently labeled plasma. From the stack of scans repeated at 1,300 Hz, the time-resolved velocity is retrieved using an image correlation approach. Single bifurcation events can be identified from a few fluorescently labeled red blood cells. The applicability of the method for in vivo measurements is illustrated on the basis of two-photon laser scanning microscopy of the cerebral capillary network of mice. Its performance is assessed with synthetic data generated from a two-phase model for the perfusion in a capillary network. The calculation of velocities is found to be sufficiently robust for a wide range of conditions. The achievable limits depend significantly on the experimental conditions and are estimated to be in the 1 μm/s (velocity) and 0.1 s (time resolution) ranges, respectively. Some manual fine-tuning is required for optimal performance in terms of accuracy and time resolution. Further work may lead to improved reliability with which bifurcation events are identified in the algorithm and to include red blood cell flux and hematocrit measurements. With the capability for time-resolved measurements in all vessels of a bifurcation, double-circle scanning trajectories allow a detailed study of the dynamics in vascular networks.

  12. Automated Methods of Corrosion Measurements

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    1997-01-01

    electrochemical measurements as well as elemental analysis look very promising for elucidating corrosion reaction mechanisms. The study of initial surface reactions at the atomic or submicron level is becoming an important field of research in the understanding of corrosion processes. At present, mainly two...... scanning microscope techniques are employed investigating corrosion processes, and usually in situ: in situ scanning tunneling microscopy (in situ STM) and in situ scanning force microscopy (in situ AFM). It is these techniques to which attention is directed here....

  13. Low level TOC measurement method

    Science.gov (United States)

    Ekechukwu, Amy A.

    2001-01-01

    A method for the determination of total organic carbon in an aqueous sample by trapping the organic matter on a sorbent which is carbon free and analyzing the sorbent by combustion and determination of total CO.sub.2 by IR.

  14. Challenges in blood pressure measurement in patients treated with maintenance hemodialysis.

    Science.gov (United States)

    Roberts, Matthew A; Pilmore, Helen L; Tonkin, Andrew M; Garg, Amit X; Pascoe, Elaine M; Badve, Sunil V; Cass, Alan; Ierino, Francesco L; Hawley, Carmel M

    2012-09-01

    The association between blood pressure and cardiovascular outcomes in patients undergoing hemodialysis remains controversial. This may relate in part to the technique and device used and the timing of the blood pressure measurement in relation to the hemodialysis procedure. Emerging evidence indicates that standardized hemodialysis unit blood pressure measurements or measurements obtained at home, either by the patient or using an ambulatory blood pressure monitor, may offer advantages over routine hemodialysis unit blood pressure measurements for determining cardiovascular risk and treatment. This review discusses the available evidence and implications for clinicians and clinical trials.

  15. Predicting stroke outcome using DCE-CT measured blood velocity

    Science.gov (United States)

    Oosterbroek, Jaap; Bennink, Edwin; Dankbaar, Jan Willem; Horsch, Alexander D.; Viergever, Max A.; Velthuis, Birgitta K.; de Jong, Hugo W. A. M.

    2015-03-01

    CT plays an important role in the diagnosis of acute stroke patients. Dynamic contrast enhanced CT (DCE-CT) can estimate local tissue perfusion and extent of ischemia. However, hemodynamic information of the large intracranial vessels may also be obtained from DCE-CT data and may contain valuable diagnostic information. We describe a novel method to estimate intravascular blood velocity (IBV) in large cerebral vessels using DCE-CT data, which may be useful to help predict stroke outcome. DCE-CT scans from 34 patients with isolated M1 occlusions were included from a large prospective multi-center cohort study of patients with acute ischemic stroke. Gaussians fitted to the intravascular data yielded the time-to-peak (TTP) and cerebral-blood-volume (CBV). IBV was computed by taking the inverse of the TTP gradient magnitude. Voxels with a CBV of at least 10% of the CBV found in the arterial input function were considered part of a vessel. Mid-sagittal planes were drawn manually and averages of the IBV over all vessel-voxels (arterial and venous) were computed for each hemisphere. Mean-hemisphere IBV differences, mean-hemisphere TTP differences, and hemisphere vessel volume differences were used to differentiate between patients with good and bad outcome (modified Rankin Scale score <3 versus ≥3 at 90 days) using ROC analysis. AUCs from the ROC for IBV, TTP, and vessel volume were 0.80, 0.67 and 0.62 respectively. In conclusion, IBV was found to be a better predictor of patient outcome than the parameters used to compute it and may be a promising new parameter for stroke outcome prediction.

  16. Comparison of Different Blood Collection, Sample Matrix, and Immunoassay Methods in a Prenatal Screening Setting

    Directory of Open Access Journals (Sweden)

    Jeroen L. A. Pennings

    2014-01-01

    Full Text Available We compared how measurements of pregnancy-associated plasma protein A (PAPP-A and the free beta subunit of human chorionic gonadotropin (fβ-hCG in maternal blood are influenced by different methods for blood collection, sample matrix, and immunoassay platform. Serum and dried blood spots (DBS were obtained by venipuncture and by finger prick of 19 pregnant women. PAPP-A and fβ-hCG from serum and from DBS were measured by conventional indirect immunoassay on an AutoDELFIA platform and by antibody microarray. We compared methods based on the recoveries for both markers as well as marker levels correlations across samples. All method comparisons showed high correlations for both marker concentrations. Recovery levels of PAPP-A from DBS were 30% lower, while those of fβ-hCG from DBS were 50% higher compared to conventional venipuncture serum. The recoveries were not affected by blood collection or immunoassay method. The high correlation coefficients for both markers indicate that DBS from finger prick can be used reliably in a prenatal screening setting, as a less costly and minimally invasive alternative for venipuncture serum, with great logistical advantages. Additionally, the use of antibody arrays will allow for extending the number of first trimester screening markers on maternal and fetal health.

  17. Measuring and developing Communities of Practice in a blood analysis unit

    DEFF Research Database (Denmark)

    Jørgensen, Rasmus; Edwards, Kasper

    2016-01-01

    developing and measuring CoP is lacking. We propose a method to measure and develop CoP and the method is tested in a blood analysis unit at ‘Nordsjællands Hospital’ in Denmark. Material and method: The practice was operationalized narrowly as employees performing a specific maintenance task. A questionnaire...... was developed based on a CoP literature review. Using the ‘think aloud’ method the questionnaire was tested with practitioners investigating if questions were decoded correctly and triggered the desired mental image. CoP level was measured at baseline and at follow-up (seven weeks after the intervention......Introduction: Knowledge sharing is essential to develop operational efficiency and quality. However, knowledge sharing is difficult to achieve due to 24-7 shifts, patient contact and little time for meetings. The theory of communities of practice (CoP) proposes an alternate approach to knowledge...

  18. DETECTION OF BLOOD VESSELS AND MEASUREMENT OF VESSEL WIDTH FOR DIABETIC RETINOPATHY

    Directory of Open Access Journals (Sweden)

    S.Sukanya

    2014-09-01

    Full Text Available The proposed method measures the retinal blood vessel diameter to identify arteriolar narrowing, arteriovenous (AV nicking, branching coefficients to detect early diabetic retinopathy. It utilizes the vessel centerline and edge information to measure the width for a vessel segment. From the input retinal image, the vascular network is extracted using the local entropy thresholding method. The vessel boundaries are extracted using sobel edge detection method. The skeletonization operation is applied to the vascular network and mapping the vessel boundaries and the skeleton image. The branching point detection method is then performed to localize all crossing locations. A rotational invariant mask to search the pixel pairs from the edge image, and calculate the shortest distance pair which provides the vessel width (or diameter for that cross-section. Variation in the width measurement identifies the diabetic retinopathy.

  19. BLOOD LEUKOCYTES PHENOTYPING BY HEMATOFLOW METHOD IN PATIENTS WITH ONYCHOMYCOSIS

    Directory of Open Access Journals (Sweden)

    A. A. Savchenko

    2015-01-01

    Full Text Available The aim of the investigation was to evaluate the information content of Hematoflow method in the pathogenetic significance in determining the violations of the cellular responses of innate and adaptive immunity, as well as the decision on the appointment of immunotropic treatment of patients with onychomycosis. The study involved 42 patients with onychomycosis feet and hands/feet at the age of 20–45 years before the appointment of a systemic antifungal therapy. The diagnosis of mycosis, onychomycosis was confirmed by microscopic examination of the fragments of the damaged nail plate. The growth of the fungus culture on special media was observed in 64% of patients. 24 healthy persons were examined as controls. A study of the phenotype of white blood cells was performed on a dual-platform technology hematology analyzer and flow cytometry using a set of antibodies Cytodiff: CD36-FITC, CD2-PE, CD294(CRTH2-PE, CD19-ECD, CD16-PC5 и CD45-PC7. The phenotypic composition evaluation of the white blood cells by the Hematoflow method allowed to establish in patients with onychomycosis the violation cellular innate and adaptive immunity. Minor changes were detected in the population composition of granule cells in the peripheral blood of patients manifested to an increase in the content of the young and segmented granulocytes. When monotsitopeniya patients with onychomycosis increases the content of the «classic» monocytes and decreases the level of «non-classical» monocytes. Changes in the composition of blood monocytes subpopulation identified in patients with the infection lasting up to 3 years and stored in the course of the disease. The most pronounced changes were found in patients with onychomycosis by the performance of adaptive immunity. Lymphopenia in these patients is realized by reducing the number of immature and mature B-cell, but by increasing the content of T-lymphocytes. Moreover, if the content of immature B-cells have decreased in

  20. Methods for measurement of durability parameters

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan De Place

    1996-01-01

    Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included.......Present selected methods for measurement of durabilty parameters relating to chlorides, corrosion, moisture and freeze-thaw, primarly on concrete. Advantages and drawbacks of the different methods are included....

  1. Measuring skewness of red blood cell deformability distribution by laser ektacytometry

    Energy Technology Data Exchange (ETDEWEB)

    Nikitin, S Yu; Priezzhev, A V; Lugovtsov, A E [International Laser Center, M. V. Lomonosov Moscow State University, Moscow (Russian Federation); Ustinov, V D [M. V. Lomonosov Moscow State University, Faculty of Computational Mathematics and Cybernetics, Moscow (Russian Federation)

    2014-08-31

    An algorithm is proposed for measuring the parameters of red blood cell deformability distribution based on laser diffractometry of red blood cells in shear flow (ektacytometry). The algorithm is tested on specially prepared samples of rat blood. In these experiments we succeeded in measuring the mean deformability, deformability variance and skewness of red blood cell deformability distribution with errors of 10%, 15% and 35%, respectively. (laser biophotonics)

  2. Evaluation of Existing Methods for Human Blood mRNA Isolation and Analysis for Large Studies

    OpenAIRE

    Meyer, Anke; Paroni, Federico; Günther, Kathrin; Dharmadhikari, Gitanjali; Ahrens, Wolfgang; Kelm, Sørge; Maedler, Kathrin

    2016-01-01

    Aims Prior to implementing gene expression analyses from blood to a larger cohort study, an evaluation to set up a reliable and reproducible method is mandatory but challenging due to the specific characteristics of the samples as well as their collection methods. In this pilot study we optimized a combination of blood sampling and RNA isolation methods and present reproducible gene expression results from human blood samples. Methods The established PAXgeneTM blood collection method (Qiagen)...

  3. The Correlation between Systolic Blood Pressure Measured by Return to Flow Versus Systolic Blood Pressure Measured by Arterial Catheter in the Adult Anesthetized Patient.

    Science.gov (United States)

    1986-12-01

    a U-tube and mercury manometer for other research, he did not use it to measure arterial blood pressure (30). It was almost a century 34 N N 35 later...use of this mercury manometer decreased the size of the measuring apparatus more than 27 times (30). Carl Ludwig made an important contribution to...direct measurement of blood pressure in 1847 when he added a i graphic recording device to the mercury manometer . This eliminated observer error and

  4. [A conductometric method of measuring enzymatic catalysis].

    Science.gov (United States)

    Dziadevych, S V; Soldatkin, O P

    1994-01-01

    Theoretical bases of the conductometric method of measurements are considered, respective formulas and equations are presented. The possibilities of application of this method for registration of the enzyme processes are shown, as well as examples of its use in conductometric classic procedure and in conductometric enzyme biosensors. Different methods of immobilization of the biological material on the surface of the transducers, schemes and methods of measurements are presented, the advantages and disadvantages of this method as compared with general biochemical methods are discussed.

  5. Reliability of blood pressure measurement and cardiovascular risk prediction

    NARCIS (Netherlands)

    van der Hoeven, N.V.

    2016-01-01

    High blood pressure is one of the leading risk factors for cardiovascular disease, but difficult to reliably assess because there are many factors which can influence blood pressure including stress, exercise or illness. The first part of this thesis focuses on possible ways to improve the reliabili

  6. Blood flow rate measurements with indicator techniques revisited

    DEFF Research Database (Denmark)

    Sejrsen, Per; Bülow, Jens

    2009-01-01

    In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions...

  7. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubula...

  8. A comparison of blood pressure measurements in newborns.

    LENUS (Irish Health Repository)

    O'Shea, Joyce

    2012-02-01

    Blood pressure monitoring is an essential component of neonatal intensive care. We compared invasive and noninvasive (Dinamap, Marquette, and Dash) recordings in newborns and also noninvasive values obtained from upper and lower limbs. Infants\\' blood pressure was recorded every 6 hours for 72 hours using three noninvasive devices and compared with invasive readings taken simultaneously. Twenty-five babies were enrolled in the study, with birth weights of 560 to 4500 g and gestation 24 + 1 to 40 + 5 weeks. Three hundred thirty-two recordings were obtained. Comparison between invasive and noninvasive readings revealed that all three noninvasive monitors overread mean blood pressure. There was no significant difference between the cuff recordings obtained from the upper or lower limbs. All three noninvasive devices overestimated mean blood pressure values compared with invasive monitoring. Clinicians may be falsely reassured by noninvasive monitoring. Mean blood pressure values obtained from the upper and lower limb are similar.

  9. Effects of blood sample handling procedures on measurable inflammatory markers in plasma, serum and dried blood spot samples

    DEFF Research Database (Denmark)

    Skogstrand, K.; Thorsen, P.; Vogel, I.

    2008-01-01

    and stored for other purposes, justifies the study hereof. Blood samples were stored for 0, 4, 24, and 48 h at 4 degrees C, room temperature (RT), and at 35 degrees C, respectively, before they were separated into serum or plasma and frozen. Dried blood spot samples (DBSS) were stored for 0, 1, 2, 3, 7......The interests in monitoring inflammation by immunoassay determination of blood inflammatory markers call for information on the stability of these markers in relation to the handling of blood samples. The increasing use of stored biobank samples for such ventures that may have been collected...... increased when blood samples were stored for a period of time before the centrifugation, for certain cytokines more than 1000 fold compared to serum and plasma isolated and frozen immediately after venepuncture. The concentrations in serum generally increased more than in plasma. The measurable...

  10. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  11. Capillary bedside blood glucose measurement in neonates: missing a diagnosis of galactosemia.

    Science.gov (United States)

    Özbek, Mehmet Nuri; Öcal, Murat; Tanrıverdi, Sibel; Baysal, Birsen; Deniz, Ahmet; Öncel, Kahraman; Demirbilek, Hüseyin

    2015-03-01

    A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further investigation led to a diagnosis of classical galactosemia. Capillary blood glucose level measured with glucometer also dropped to normal values following cessation of breastfeeding and initiation of feeding with a lactose-free formula.

  12. 食蟹猴外周血淋巴细胞亚群的流式法分析验证和正常参考值测定%Method validation and determination of normal reference values of peripheral blood lymphocytes phenotyping measure-ment in cynomolgus monkeys using flow cytometry

    Institute of Scientific and Technical Information of China (English)

    黄秋香; 孙建华; 秦秋平; 王英; 邱淑怡; 孙晓旭; 黄桂华; 宫丽崑; 任进

    2015-01-01

    目的:建立并验证流式细胞法检测食蟹猴外周血淋巴细胞亚群(辅助性 T 细胞、细胞毒性 T 细胞、B细胞、NK 细胞)的方法,建立正常参考值范围,比较性别和年龄差异。方法 EDTA‐K2抗凝管采集食蟹猴血样,采用两组三色荧光抗体组合 CD3‐FITC/CD4‐PerCP/CD8‐PE 、CD3‐PE‐CYTM 5.5/CD16‐PE/CD20‐FITC 进行细胞分类检测。测定批内差异和批间差异以考察方法精密度;并分别对血样室温放置6 h ,4℃放置24 h ,检测处理后样本4℃放置24h 的样品稳定性进行考察。进一步扩大检测样本数量,确立不同性别、年龄段的正常参考值范围,并比较性别和年龄差异。结果精密度检测各指标批内变异度为2.51%~12.51%,批间变异度为1.32%~8.63%。血样经不同处理和放置不同时间后的测定结果与新鲜采集血样后的检测结果偏差均小于10%。确立了1.5~2岁和3~5岁两个年龄段,雌雄食蟹猴淋巴细胞亚群的正常参考值。比较发现,3~5岁与1.5~2岁相比,外周血 NK 细胞(CD3- CD16+)亚群比例升高;B 淋巴细胞(CD3- CD20+)亚群有年龄和性别差异。结论食蟹猴外周血淋巴细胞亚群检测的血液样本在室温放置6 h ,4℃放置24 h 内检测,或处理后4℃放置24 h 内检测,结果稳定性良好。不同年龄段和性别食蟹猴的淋巴细胞亚群正常值范围具有差异,提示选择食蟹猴进行相关研究评价时应予以注意。%Objective To establish and validate the method of peripheral blood lymphocytes phenotyping test in cynomolgus monkeys (including helper T lymphocyte ,cytotoxic T lymphocyte ,B lymphocyte and NK cell) using flow cytometry and determine reference value of the general peripheral blood lymphocytes phenotyping and compare the differences between ages and sexes .Methods Collect blood samples in EDTA‐K2 anticoagulant tube from

  13. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before...... and after ventilation with a gas mixture containing 20-50 ml of CO for a period of 10-15 min. A special Water's to and fro system was designed in order to avoid any leakage when measuring during intermittent positive pressure ventilation (IPPV). Blood samples were taken before and immediately after......, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)...

  14. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Beaver, W. L.; Meindl, J. D.

    1976-01-01

    Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.

  15. Measuring high-sensitivity cardiac troponin T blood concentration in population surveys

    Science.gov (United States)

    Mindell, Jennifer S.

    2017-01-01

    Introduction The blood test for high-sensitivity cardiac troponin T (HS-CTnT) has been proposed as a marker of cardiovascular risk in the general population, as it is associated with subsequent incidence of cardiovascular events and mortality. We aimed at evaluating the feasibility of HS-CTnT testing within large nationally-representative population surveys in which blood samples are collected during household visits, shipped using the standard civil postal service, and then frozen for subsequent analyses. Methods The Health Survey for England (HSE) consists of a series of annual surveys beginning in 1991. It is designed to provide regular information on various aspects of the nation’s health and risk factors. We measured HS-CTnT in the blood of 200 people from the HSE 2016 wave, then froze and stored their blood samples at -40°C for 5–10 weeks, and then thawed and retested them to appreciate the extent of within-person agreement or test-retest reliability of the two measurements. Results The Cronbach's Alpha (Scale Reliability Coefficient) and the Interclass Correlation Coefficient (two-way mixed-effects model for consistency of agreement at individual level) were 0.97 (95%CI = 0.96–0.99) and 0.95 (95%CI = 0.94–0.96) respectively. The time delay from blood withdrawal to analysis and storage (1–4 days) did not affect the results, nor did the freezing time before the retest (5–10 weeks). Conclusion The measurement of HS-CTnT plasma concentration within large nationally-representative surveys such as the Health Survey for England is feasible. PMID:28141863

  16. Level of Mercury Manometer With Respect to Heart: Does it Affect Blood Pressure Measurement?

    Science.gov (United States)

    Kapoor, Raj; Roy, V K; Manna, S; Bhattacharjee, M

    2015-01-01

    Measurement of blood pressure is an integral part of clinical examination. Over the years various types of instruments have been used to measure blood pressure but till date the mercury sphygmomanometer is regarded as the gold standard. However, there is a myth prevalent among health professionals regarding the level of the manometer in relation to heart at the time of measuring of blood pressure. Many professionals insist that it has to be placed at the level of the heart. We argue that the limb from which pressure is measured must be at the heart level rather than the manometer. We conducted a study in which we measured the blood pressure in adults by placing the manometer at three different levels with respect to the heart. The values of blood pressure obtained at all levels were similar and did not show any statistically significant difference. We therefore conclude that the level of sphygmomanometer per se does not affect blood pressure measurement.

  17. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E;

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...... subjects using three different MRI techniques: arterial spin labeling (ASL), dynamic contrast enhanced T1 weighted perfusion MRI (DCE) and phase contrast mapping (PCM). All MRI measurements were performed within the same session. In 10 of the subjects repeated CBF measurements by (15) O labeled water PET......L/100 g/min, 16.2% and 4.8%, for DCE 43.0 mL/100 g/min, 20.0%, 15.1% and for PET 41.9 mL/100 g/min, 16.5% and 11.9%, respectively. Only for DCE and PCM a significant positive correlation between measurements was demonstrated. CONCLUSION: These findings confirm large between subject variability in CBF...

  18. [Coronary artery blood flow velocity non-invasively measured using a vessel-tracking pulsed Doppler system].

    Science.gov (United States)

    Tateishi, O; Aizawa, O; Okamura, T; Yoshida, T; Furuhata, H; Seo, Y; Iinuma, K; Shiki, E

    1988-09-01

    A newly-developed noninvasive method was used to measure left coronary blood flow during phantom experiments. Two techniques were used in which: (1) the sample position can always be set in a fluctuating vessel using a wall echo-tracking method with a phase-locked-loop, and (2) the Doppler reference signal was generated separately synchronous with the wall echo signal. These techniques were combined, using a commercially available pulsed Doppler apparatus (SSH-40B: Toshiba). Basic experiments were performed using a blood vessel phantom to verify the validity of these systems. Blood flow velocity in the fluctuating tube could be measured clearly using a vessel-tracking method. The blood flow velocity of the left anterior descending artery was measured in three normal subjects and in seven patients from the third intercostal space along the left sternal border. The velocity pattern was characterized by a crescendo-decrescendo shape in diastole. The peak velocity which appeared in diastole ranged from 19 to 69 cm/sec, with no difference by disease entity. However, in all cases, the blood flow velocity signals were marred by extraneous signals, making it impossible to measure blood flow velocity during systole. Further improvement of the system is mandatory in order to use this flowmeter clinically.

  19. Screening blood pressure measurement in children: are we saving lives?

    Science.gov (United States)

    Brady, Tammy M; Redwine, Karen M; Flynn, Joseph T

    2014-06-01

    Blood Pressure screening in children and adolescents is currently recommended by several prominent medical organizations, including the American Heart Association, the National High Blood Pressure Education Program, the National Heart, Lung, and Blood Institute, the European Society of Hypertension, and the American Academy of Pediatrics. This practice was recently subject to intense scientific review by the U.S. Preventive Services Task Force. The conclusion of the Task Force was that "current evidence is insufficient to assess the balance of benefits and harms of screening for primary hypertension in asymptomatic children and adolescents." This commentary provides an alternate interpretation of current evidence for blood pressure screening in children and adolescents and highlights its importance as a part of routine medical care.

  20. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  1. [Reliability of blood pressure measurements; comparison of an electronic meter and a mercury manometer in family practice].

    Science.gov (United States)

    van Doorn, B A; van der Does, E; Lubsen, J; Rijsterborgh, H

    1990-08-25

    The Riva-Rocci indirect method of measuring the blood pressure carries a number of sources of error. A report is presented of a study of the serviceability of an electronic blood pressure meter as compared with the conventional mercury manometer. Seventy-six paired measurements were carried out in patients selected at random using an electronic blood pressure meter and a mercury manometer meeting all Health Council requirements. The systematic error and the incidental error in both measuring procedures were compared. The differences found were so slight as to be negligible in practice. It is concluded that the electronic blood pressure meter in practice constitutes an acceptable substitute for the conventional mercury manometer.

  2. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  3. Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels.

    Science.gov (United States)

    Dasgupta, Subhashish; Banerjee, Rupak K; Hariharan, Prasanna; Myers, Matthew R

    2011-02-01

    Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be made on the basis of the measurements. Thermocouple artifact due to viscous heating is one source of error. A second is the uncertainty regarding the position of the beam relative to the target location or the thermocouple junction, due to the error in positioning the beam at the junction. This paper presents a method for determining the location of the beam relative to a fixed pair of thermocouples. The localization technique reduces the uncertainty introduced by positioning errors associated with very narrow HIFU beams. The technique is presented in the context of an investigation into the effect of blood flow through large vessels on the efficacy of HIFU procedures targeted near the vessel. Application of the beam localization method allowed conclusions regarding the effects of blood flow to be drawn from previously inconclusive (because of localization uncertainties) data. Comparison of the position-adjusted transient temperature profiles for flow rates of 0 and 400ml/min showed that blood flow can reduce temperature elevations by more than 10%, when the HIFU focus is within a 2mm distance from the vessel wall. At acoustic power levels of 17.3 and 24.8W there is a 20- to 70-fold decrease in thermal dose due to the convective cooling effect of blood flow, implying a shrinkage in lesion size. The beam-localization technique also revealed the level of thermocouple artifact as a function of sonication time, providing investigators with an indication of the quality of thermocouple data for a given exposure time. The maximum artifact was found to be double the measured temperature rise, during initial few seconds of sonication.

  4. Comparison of three different methods of total carbon dioxide measurement.

    Science.gov (United States)

    Kilborn, Susan H.; Bonnett, Brenda N.; Pook, Harold A.

    1995-01-01

    The objective of this study was to compare total carbon dioxide (TCO(2)) levels measured by three different methods. Two hundred jugular venous blood samples from dogs admitted to the Veterinary Teaching Hospital, Ontario Veterinary College with various clinical disorders were analyzed by the Radiometer blood gas analyzer (BGA) and the Coulter DACOS analyzer. In 70 of these samples, TCO(2) was also measured by the Kodak Ektachem DTE chemistry analyzer. Comparison of the agreement between methods revealed intraclass correlation coefficients (ICC) of 0.63, 0.79, and 0.82 for the DACOS-Ektachem, DACOS-BGA and Ektachem-BGA comparisons, respectively. Evaluation of the effect of storage time on TCO(2) content of stored serum samples measured on the DACOS analyzer revealed a decrease of almost 2 mmol/L and a decrease in the intraclass correlation coefficient values between the DACOS analyzer and other methods after 7 hours storage time. The results of this observational study revealed lower agreement between the three methods in this study than previously reported between other methods of TCO(2) measurement. Possible reasons for the lower than expected agreement in this study included changes in DACOS values because of storage and differences in methodologies between the methods.

  5. Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation.

    Science.gov (United States)

    Kollias, Anastasios; Stergiou, George S

    2014-01-01

    1. Hypertension and atrial fibrillation (AF) often coexist and are strong risk factors for stroke. Current guidelines for blood pressure (BP) measurement in AF recommend repeated measurements using the auscultatory method, whereas the accuracy of the automated devices is regarded as questionable. This review presents the current evidence on the feasibility and accuracy of automated BP measurement in the presence of AF and the potential for automated detection of undiagnosed AF during such measurements. 2. Studies evaluating the use of automated BP monitors in AF are limited and have significant heterogeneity in methodology and protocols. Overall, the oscillometric method is feasible for static (office or home) and ambulatory use and appears to be more accurate for systolic than diastolic BP measurement. 3. Given that systolic hypertension is particularly common and important in the elderly, the automated BP measurement method may be acceptable for self-home and ambulatory monitoring, but not for professional office or clinic measurement. 4. An embedded algorithm for the detection of asymptomatic AF during routine automated BP measurement with high diagnostic accuracy has been developed and appears to be a useful screening tool for elderly hypertensives.

  6. Novel, high-yield red blood cell production methods from CD34-positive cells derived from human embryonic stem, yolk sac, fetal liver, cord blood, and peripheral blood.

    Science.gov (United States)

    Olivier, Emmanuel; Qiu, Caihong; Bouhassira, Eric E

    2012-08-01

    The current supply of red blood cells expressing rare blood groups is not sufficient to cover all the existing transfusion needs for chronically transfused patients, such as sickle cell disease homozygous carriers, because of alloimmunization. In vitro production of cultured red blood cells is slowly emerging as a possible complement to the existing collection-based red blood cell procurement system. The yield of cultured red blood cells can theoretically be maximized by amplifying the stem, progenitor, or precursor compartment. Here, we combined methods designed to expand these three compartments to optimize the yield of cultured red blood cells and found that exposing CD34(+) cells to a short pulse of cytokines favorable for erythroid differentiation prior to stem cell expansion followed by progenitor expansion produced the highest yield of erythroid cells. This novel serum-free red blood cell production protocol was efficient on CD34(+) cells derived from human embryonic stem cells, 6-8-week yolk sacs, 16-18-week fetal livers, cord blood, and peripheral blood. The yields of cells obtained with these new protocols were larger by an order of magnitude than the yields observed previously. Globin expression analysis by high-performance liquid chromatography revealed that these expansion protocols generally yielded red blood cells that expressed a globin profile similar to that expected for the developmental age of the CD34(+) cells.

  7. Normal and system lupus erythematosus red blood cell interactions studied by double trap optical tweezers: direct measurements of aggregation forces

    Science.gov (United States)

    Khokhlova, Maria D.; Lyubin, Eugeny V.; Zhdanov, Alexander G.; Rykova, Sophia Yu.; Sokolova, Irina A.; Fedyanin, Andrey A.

    2012-02-01

    Direct measurements of aggregation forces in piconewton range between two red blood cells in pair rouleau are performed under physiological conditions using double trap optical tweezers. Aggregation and disaggregation properties of healthy and pathologic (system lupus erythematosis) blood samples are analyzed. Strong difference in aggregation speed and behavior is revealed using the offered method which is proposed to be a promising tool for SLE monitoring at single cell level.

  8. A novel method to estimate oxygen saturation of the internal jugular vein blood

    Science.gov (United States)

    Li, Kai; Pan, Boan; Gao, Yuan; Ruan, Zhengshang; Li, Ting

    2016-03-01

    This article introduces a novel method to estimate oxygen saturation of the internal jugular vein blood (SjvO2) by using Near Infrared spectroscopy (NIRS). The different positions of patients can affect the cross-sectional area (CSA) of the internal jugular vein (IJV), in other words, it causes the sectional change of the IJV blood volume. When lying position of patients, the CSA is larger than that keeping upper body 80 degree, and the CSA can compute quantitatively by the use of ultrasound and digital image processing methods. The entire method consist of constructing different position of patient (upper body rotation 0 and 80 degree), comparing the light absorption changes. SjvO2 has been determined from light absorption measurements in two wavelength, before and after the position changes. The method has been applied to the vertical area over the IJV of 11 patients who were placed a central venous catheter into a large vein in the neck for medical uses, using wavelength of 735 and 850 nm. At last, comparing the SjvO2NIRS which measured by NIRS noninvasively with SjvO2IJVBG which was quantified using a whole blood gas analyzer, we found there were some certain relativity. The results were influenced by vascular depth greatly.

  9. A Reconstruction Method of Blood Flow Velocity in Left Ventricle Using Color Flow Ultrasound

    Directory of Open Access Journals (Sweden)

    Jaeseong Jang

    2015-01-01

    Full Text Available Vortex flow imaging is a relatively new medical imaging method for the dynamic visualization of intracardiac blood flow, a potentially useful index of cardiac dysfunction. A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color flow images compiled from ultrasound measurements. In this paper, a 2D incompressible Navier-Stokes equation with a mass source term is proposed to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. The boundary conditions to solve the system of equations are derived from the dimensions of the ventricle extracted from 2D echocardiography data. The performance of the proposed method is evaluated numerically using synthetic flow data acquired from simulating left ventricle flows. The numerical simulations show the feasibility and potential usefulness of the proposed method of reconstructing the intracardiac flow fields. Of particular note is the finding that the mass source term in the proposed model improves the reconstruction performance.

  10. Method of measuring luminescence of a material

    Science.gov (United States)

    Miller, Steven D.

    2015-12-15

    A method of measuring luminescence of a material is disclosed. The method includes applying a light source to excite an exposed material. The method also includes amplifying an emission signal of the material. The method further includes measuring a luminescent emission at a fixed time window of about 10 picoseconds to about 10 nanoseconds. The luminescence may be radio photoluminescence (RPL) or optically stimulated luminescence (OSL).

  11. Blood

    Science.gov (United States)

    ... Also, blood is either Rh-positive or Rh-negative. So if you have type A blood, it's either A positive or A negative. Which type you are is important if you need a blood transfusion. And your Rh factor could be important ...

  12. Laser speckle contrast imaging to measure changes in cerebral blood flow.

    Science.gov (United States)

    Winship, Ian R

    2014-01-01

    Laser speckle contrast imaging (LSCI) is a powerful tool capable of acquiring detailed maps of blood flow in arteries and veins on the cortical surface. Based on the blurring of laser speckle patterns by the motion of blood cells, LSCI can be combined with a variety of optical imaging preparations to acquire high-spatiotemporal resolution images of blood flow, and track changes in blood flow over time, using relatively simple instrumentation. Here, we describe methods for LSCI of cerebral blood flow via a thin skull imaging preparation in mice or rats. This preparation allows precise semiquantitative mapping of changes in blood flow over time using straightforward surgical protocols and equipment.

  13. Measurements of Dynamic Viscoelasticity of Poly (vinyl alcohol) Hydrogel for the Development of Blood Vessel Biomodeling

    Science.gov (United States)

    Kosukegawa, Hiroyuki; Mamada, Keisuke; Kuroki, Kanju; Liu, Lei; Inoue, Kosuke; Hayase, Toshiyuki; Ohta, Makoto

    In vitro blood vessel biomodeling with realistic mechanical properties and geometrical structures is helpful for training in surgical procedures, especial those used in endovascular treatment. Poly (vinyl alcohol) hydrogel (PVA-H), which is made of Poly (vinyl alcohol) (PVA) and water, may be useful as a material for blood vessel biomodeling due to its low surface friction resistance and good transparency. In order to simulate the mechanical properties of blood vessels, measurements of mechanical properties of PVA-H were carried out with a dynamic mechanical analyzer, and the storage modulus (G’) and loss modulus (G”) of PVA-H were obtained. PVA-Hs were prepared by the low-temperature crystallization method. They were made of PVA with various concentrations (C) and degrees of polymerization (DP), and made by blending two kinds of PVA having different DP or saponification values (SV). The G’ and G” of PVA-H increased, as the C or DP of PVA increased, or as the proportion of PVA with higher DP or SV increased. These results indicate that it is possible to obtain PVA-H with desirable dynamic viscoelasticity. Furthermore, it is suggested that PVA-H is stable in the temperature range of 0°C to 40°C, indicating that biomodeling made of PVA-H should be available at 37°C, the physiological temperature. The dynamic viscoelasticity of PVA-H obtained was similar to that of the dog blood vessel measured in previous reports. In conclusion, PVA-H is suggested to be useful as a material of blood vessel biomodeling.

  14. Quantification of peripheral and central blood pressure variability using a time-frequency method.

    Science.gov (United States)

    Kouchaki, Z; Butlin, M; Qasem, A; Avolio, A P; Kouchaki, Z; Butlin, M; Qasem, A; Avolio, A P; Kouchaki, Z; Avolio, A P; Butlin, M; Qasem, A

    2016-08-01

    Systolic blood pressure variability (BPV) is associated with cardiovascular events. As the beat-to-beat variation of blood pressure is due to interaction of several cardiovascular control systems operating with different response times, assessment of BPV by spectral analysis using the continuous measurement of arterial pressure in the finger is used to differentiate the contribution of these systems in regulating blood pressure. However, as baroreceptors are centrally located, this study considered applying a continuous aortic pressure signal estimated noninvasively from finger pressure for assessment of systolic BPV by a time-frequency method using Short Time Fourier Transform (STFT). The average ratio of low frequency and high frequency power band (LFPB/HFPB) was computed by time-frequency decomposition of peripheral systolic pressure (pSBP) and derived central aortic systolic blood pressure (cSBP) in 30 healthy subjects (25-62 years) as a marker of balance between cardiovascular control systems contributing in low and high frequency blood pressure variability. The results showed that the BPV assessed from finger pressure (pBPV) overestimated the BPV values compared to that assessed from central aortic pressure (cBPV) for identical cardiac cycles (P<;0.001), with the overestimation being greater at higher power.

  15. Open Photoacoustic Cell for Blood Sugar Measurement: Numerical Calculation of Frequency Response

    CERN Document Server

    Baumann, Bernd; Teschner, Mark

    2015-01-01

    A new approach for continuous and non-invasive monitoring of the glucose concentration in human epidermis has been suggested recently. This method is based on photoacoustic (PA) analysis of human interstitial fluid. The measurement can be performed in vitro and in vivo and, therefore, may form the basis for a non-invasive monitoring of the blood sugar level for diabetes patients. It requires a windowless PA cell with an additional opening that is pressed onto the human skin. Since signals are weak, advantage is taken of acoustic resonances of the cell. Recently, a numerical approach based on the Finite Element (FE) Method has been successfully used for the calculation of the frequency response function of closed PA cells. This method has now been adapted to obtain the frequency response of the open cell. Despite the fact that loss due to sound radiation at the opening is not included, fairly good accordance with measurement is achieved.

  16. Validation of continuous noninvasive arterial blood pressure measurements during general anesthesia

    NARCIS (Netherlands)

    Kalmar, A.F.; Vos, Jaap Jan; Weening, M.; Mooyaart, E.A.; Poterman, Marieke; Struys, Michel; Scheeren, Thomas

    2012-01-01

    Background:  Continuous invasive arterial blood pressure (IBP) monitoring remains the accepted gold standard for blood pressure monitoring because of its high accuracy. Several disadvantages of this method motivate the use of noninvasive intermittent blood pressure (NIBP) in most anesthesia cases de

  17. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  18. Tomographic cerebral blood flow measurement during carotid surgery

    DEFF Research Database (Denmark)

    Rathenborg, Lisbet Knudsen; Vorstrup, Sidsel; Olsen, K S

    1994-01-01

    OBJECTIVES: The aim of the study was to depict regional cerebral blood flow (rCBF) during carotid cross clamping using 99mTechnetium-hexamethylpropylene amine oxime (TcHMPAO). This tracer rapidly passes the blood-brain barrier and is retained for hours in the brain tissue. Injecting TcHMPAO during...... RESULTS: We found a significant correlation between stump pressure and enhancement of side-to-side asymmetry in rCBF due to carotid cross clamping. Pronounced variations were seen in which regions were deprived of perfusion during clamping. CONCLUSION: TcHMPAO allows tomographic assessment of CBF during...

  19. Measuring elevated intracranial pressure through noninvasive methods

    DEFF Research Database (Denmark)

    Kristiansson, Helena; Nissborg, Emelie; Bartek, Jiri;

    2013-01-01

    . This article is a review of the current literature on noninvasive methods for measuring and evaluating elevated ICP. The main focus is on studies that compare noninvasively measured ICP with invasively measured ICP. The aim is to provide an overview of the current state of the most common noninvasive...... is associated with certain risks. Intraparenchymal ICP monitoring methods are considered to be a safer alternative but can, in certain conditions, be imprecise due to zero drift and still require an invasive procedure. An accurate noninvasive method to measure elevated ICP would therefore be desirable...

  20. Precision of INR measured with a patient operated whole blood coagulometer

    DEFF Research Database (Denmark)

    Attermann, Jørn; Andersen, Niels Trolle; Korsgaard, Helle;

    2003-01-01

    INTRODUCTION: The objective of the present study was to evaluate the precision of a portable whole blood coagulometer (CoaguChek S) in the hands of self-managing patients on oral anticoagulant therapy (OAT). MATERIALS AND METHODS: Fifteen patients on self-managed OAT performed measurements of INR...... by two types of portable whole blood coagulometers (CoaguChek and CoaguChek S) at home for 10 weeks. RESULTS: The coefficient of variation (CV) of INRs determined at home by CoaguChek S by patients on self-managed OAT was 5.5% (95% confidence limits: 4.9%, 6.1%). The biological CV of INR within...... and between patients was 15.0% and 14.7%, respectively. CONCLUSION: The precision of CoaguChek S is satisfactory....

  1. Prognostic value of blood pressure measured during hospitalization after acute myocardial infarction: an insight from survival trials

    DEFF Research Database (Denmark)

    Yap, Yee Guan; Duong, Trinh; Bland, J Martin

    2007-01-01

    BACKGROUND: The prognostic value of blood pressure measured during hospitalization after acute myocardial infarction (MI) has not been investigated, particularly with regard to arrhythmic death. METHODS: A total of 3311 placebo patients (2612 men, median age 64 years; range 23-92) from the EMIAT......). Mortality up to 2 years was examined using Cox regression. RESULTS: At the 2-year follow-up, after adjustment for age, sex, smoking, previous MI, hypertension, heart rate, New York Heart Association functional class, baseline treatments, study effect and diastolic blood pressure, reduced systolic blood...

  2. Chronic impairment of leg muscle blood flow following cardiac catheterization in childhood. [/sup 133/Xe clearance measurements

    Energy Technology Data Exchange (ETDEWEB)

    Skovranek, J.; Samanek, M.

    1979-01-01

    In 99 patients with congenital heart defects or chronic respiratory disease without clinical symptoms of disturbances in peripheral circulation, resting and maximal blood flow in the anterior tibial muscle of both extremities were investigated 2.7 yrs (average) after cardiac catheterization. The method used involved /sup 133/Xe clearance. Resting blood flow was normal and no difference could be demonstrated between the extremity originally used for catheterization and the contralateral control extremity. No disturbance in maximal blood flow could be proved in the extremity used for catheterization by the venous route only. Maximal blood flow was significantly lower in that extremity where the femoral artery had been catheterized or cannulated for pressure measurement and blood sampling. The disturbance in maximal flow was shown regardless of whether the arterial catheterization involved the Seldinger percutaneous technique, arteriotomy, or mere cannulation of the femoral artery. The values in the involved extremity did not differ significantly from the values in a healthy population.

  3. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  4. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  5. Cerebral blood flow measurement using fMRI and PET: a cross-validation study.

    Science.gov (United States)

    Chen, Jean J; Wieckowska, Marguerite; Meyer, Ernst; Pike, G Bruce

    2008-01-01

    An important aspect of functional magnetic resonance imaging (fMRI) is the study of brain hemodynamics, and MR arterial spin labeling (ASL) perfusion imaging has gained wide acceptance as a robust and noninvasive technique. However, the cerebral blood flow (CBF) measurements obtained with ASL fMRI have not been fully validated, particularly during global CBF modulations. We present a comparison of cerebral blood flow changes (DeltaCBF) measured using a flow-sensitive alternating inversion recovery (FAIR) ASL perfusion method to those obtained using H(2) (15)O PET, which is the current gold standard for in vivo imaging of CBF. To study regional and global CBF changes, a group of 10 healthy volunteers were imaged under identical experimental conditions during presentation of 5 levels of visual stimulation and one level of hypercapnia. The CBF changes were compared using 3 types of region-of-interest (ROI) masks. FAIR measurements of CBF changes were found to be slightly lower than those measured with PET (average DeltaCBF of 21.5 +/- 8.2% for FAIR versus 28.2 +/- 12.8% for PET at maximum stimulation intensity). Nonetheless, there was a strong correlation between measurements of the two modalities. Finally, a t-test comparison of the slopes of the linear fits of PET versus ASL DeltaCBF for all 3 ROI types indicated no significant difference from unity (P > .05).

  6. Cerebral Blood Flow Measurement Using fMRI and PET: A Cross-Validation Study

    Directory of Open Access Journals (Sweden)

    Jean J. Chen

    2008-01-01

    Full Text Available An important aspect of functional magnetic resonance imaging (fMRI is the study of brain hemodynamics, and MR arterial spin labeling (ASL perfusion imaging has gained wide acceptance as a robust and noninvasive technique. However, the cerebral blood flow (CBF measurements obtained with ASL fMRI have not been fully validated, particularly during global CBF modulations. We present a comparison of cerebral blood flow changes (ΔCBF measured using a flow-sensitive alternating inversion recovery (FAIR ASL perfusion method to those obtained using H2O15 PET, which is the current gold standard for in vivo imaging of CBF. To study regional and global CBF changes, a group of 10 healthy volunteers were imaged under identical experimental conditions during presentation of 5 levels of visual stimulation and one level of hypercapnia. The CBF changes were compared using 3 types of region-of-interest (ROI masks. FAIR measurements of CBF changes were found to be slightly lower than those measured with PET (average ΔCBF of 21.5±8.2% for FAIR versus 28.2±12.8% for PET at maximum stimulation intensity. Nonetheless, there was a strong correlation between measurements of the two modalities. Finally, a t-test comparison of the slopes of the linear fits of PET versus ASL ΔCBF for all 3 ROI types indicated no significant difference from unity (P>.05.

  7. Measurement of interaction forces between red blood cells in aggregates by optical tweezers

    Energy Technology Data Exchange (ETDEWEB)

    Maklygin, A Yu; Priezzhev, A V; Karmenian, A; Nikitin, Sergei Yu; Obolenskii, I S; Lugovtsov, Andrei E; Kisun Li

    2012-06-30

    We have fabricated double-beam optical tweezers and demonstrated the possibility of their use for measuring the interaction forces between red blood cells (erythrocytes). It has been established experimentally that prolonged trapping of red blood cells in a tightly focused laser beam does not cause any visible changes in their shape or size. We have measured the interaction between red blood cells in the aggregate, deformed by optical tweezers.

  8. Measures of blood pressure and cognition in dialysis patients

    Science.gov (United States)

    There are few reports on the relationship of blood pressure with cognitive function in maintenance dialysis patients. The Cognition and Dialysis Study is an ongoing investigation of cognitive function and its risk factors in six Boston area hemodialysis units. In this analysis, we evaluated the rela...

  9. Blood Pressure over Height Ratios: Simple and Accurate Method of Detecting Elevated Blood Pressure in Children

    Directory of Open Access Journals (Sweden)

    Ovidiu Galescu

    2012-01-01

    Full Text Available Background. Blood pressure (BP percentiles in childhood are assessed according to age, gender, and height. Objective. To create a simple BP/height ratio for both systolic BP (SBP and diastolic BP (DBP. To study the relationship between BP/height ratios and corresponding BP percentiles in children. Methods. We analyzed data on height and BP from 2006-2007 NHANES data. BP percentiles were calculated for 3775 children. Receiver-operating characteristic (ROC curve analyses were performed to calculate sensitivity and specificity of BP/height ratios as diagnostic tests for elevated BP (>90%. Correlation analysis was performed between BP percentiles and BP/height ratios. Results. The average age was 12.54 ± 2.67 years. SBP/height and DBP/height ratios strongly correlated with SBP & DBP percentiles in both boys (<0.001, 2=0.85, 2=0.86 and girls (<0.001, 2=0.85, 2=0.90. The cutoffs of SBP/height and DBP/height ratios in boys were ≥0.75 and ≥0.46, respectively; in girls the ratios were ≥0.75 and ≥0.48, respectively with sensitivity and specificity in range of 83–100%. Conclusion. BP/height ratios are simple with high sensitivity and specificity to detect elevated BP in children. These ratios can be easily used in routine medical care of children.

  10. Occlusion cuff for routine measurement of digital blood pressure and blood flow

    DEFF Research Database (Denmark)

    Lassen, N A; Krähenbühl, B; Hirai, M

    1977-01-01

    A miniaturized blood pressure cuff made of plastic material and applicable to fingers and toes is described. The cuff was compared to rubber cuffs and to bladder-free cuffs. It was found to be more reliable than the former type and much easier to use than the latter type. It is recommended for us...

  11. A comparison of two methods for calculating CR (time constant) during studies of arterial blood flow in rats.

    Science.gov (United States)

    Sasaoka, K; Ogawa, K

    1990-11-01

    Some of our earlier reports have dealt with experiments on the central caudal arteries of a series of anesthetized rats. The results of these experiments were expressed by a relationship derived from the Windkessel theory where f(t) = alpha dz(t)/dt + beta z(t). When this theory is used, the measured blood flow forms f(t) and calculated wave forms alpha dz(t)/dt + beta z(t) agree closely. In these studies, we discovered that, when blood flow adz(t)/dt + beta z(t) agree closely. In these studies, we discovered that, when blood flow decreases, CR (time constant tau, the product of the blood vessel compliance C and the peripheral resistance R) values increase and vary widely. In the present study, 1) we investigated changes in CR when blood flow increases, and, 2) the method of least squares was used in calculating the formula given above. We achieved a better conformity between measured blood flow and calculated blood flow and perceived a clearer relationship between mean blood flow and CR than when they were calculated by the old method.

  12. Blood volume measurement with indocyanine green pulse spectrophotometry: dose and site of dye administration

    NARCIS (Netherlands)

    M.R. Germans; P.C. de Witt Hamer; L.J. van Boven; K.A.H. Zwinderman; G.J. Bouma

    2010-01-01

    (1) To determine the optimal administration site and dose of indocyanine green (ICG) for blood volume measurement using pulse spectrophotometry, (2) to assess the variation in repeated blood volume measurements for patients after subarachnoid hemorrhage and (3) to evaluate the safety and efficacy of

  13. Methodological aspects of blood pressure measurement and adherence to antihypertensive drug therapy

    NARCIS (Netherlands)

    Braam, R.L.

    2007-01-01

    Hypertension is an important risk-factor for cardiovascular disease. Accurate blood pressure measurements are very important to diagnose hypertension. Nowadays these blood pressure measurements are often performed using automatic devices. One can wonder whether these devices are accurate enough. In

  14. Endoscopic Doppler ultrasound for measurement of azygos blood flow. Validation against thermodilution and assessment of pharmacological effects of terlipressin in portal hypertension

    DEFF Research Database (Denmark)

    2001-01-01

    BACKGROUND: Endoscopic ultrasound (EUS) is a new modality allowing real-time flow measurements by means of the Doppler technique. The aim of the study was to evaluate azygos blood flow measurements by endoscopic ultrasound. METHODS: Measurements of azygos blood flow by EUS and by the thermodilution....... RESULTS: The EUS Doppler and thermodilution measurements correlated significantly (R=0.81, P blood flow was found to be 14% higher by the EUS method than by thermodilution. The coefficient of variation of the EUS Doppler measurements of the azygos blood flow was 14.8%. After...... administration of terlipressin, the azygos blood flow, as measured by EUS Doppler, decreased significantly by 23% from 915 to 704 ml/min (P = 0.014) and the portal venous flow decreased by 28% from 1170 to 789 ml/min (P = 0.03). No effects of placebo were detected. CONCLUSIONS: These results show that EUS...

  15. Measuring method for optical fibre sensors

    NARCIS (Netherlands)

    Lammerink, T.S.J.; Fluitman, J.H.J.

    1984-01-01

    A new measuring method for the signal amplitude in intensity modulating fibre optic sensors is described. A reference signal is generated in the time domain. The method is insensitive for the sensitivity fluctuations of the light transmitter and the light receiver. The method is experimentally teste

  16. Diagnostic Methods for Detection of Blood-Borne Candidiasis.

    Science.gov (United States)

    Clancy, Cornelius J; Nguyen, M Hong

    2016-01-01

    β-D-glucan (Fungitell) and polymerase chain reaction-based (T2Candida) assays of blood samples are FDA-approved adjuncts to cultures for diagnosing candidemia and other types of invasive candidiasis, but their clinical roles are unclear. In this chapter, we describe laboratory protocols for performing Fungitell and T2Candida assays. We then discuss step-by-step methods for interpreting test results at the bedside using a Bayesian framework, and for incorporating assays into rational patient management strategies. Prior to interpreting results, clinicians must recognize that test performance varies based on the type of invasive candidiasis being diagnosed. In general, the type of invasive candidiasis that is most likely in a given patient can be identified, and the pretest likelihood of disease estimated. From there, positive and negative predictive values (PPV, NPV) for an assay can be calculated. At a population level, tests can be incorporated into screening strategies for antifungal treatment. NPV and PPV thresholds can be defined for discontinuing antifungal prophylaxis or initiating preemptive treatment, respectively. Using the thresholds, it is possible to assign windows of pretest likelihood for invasive candidiasis (and corresponding patient populations) in which tests are most likely to valuable. At the individual patient level, tests may be useful outside of the windows proposed for screening populations. The interpretive and clinical decision-making processes we discuss will be applicable to other diagnostic assays as they enter the clinic, and to existing assays as more data emerge from various populations.

  17. Important Considerations for Methemoglobin Measurement in Fish Blood: Assay Choice and Storage Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kuntz, Mel Anton; Rodnick, K. J.; J. A. Lacey

    2002-05-01

    Spectrophotometric assays of methaemoglobin (metHb) in rainbow trout Oncorhynchus mykiss, channel catfish Ictalurus punctatus, tilapias Tilapia niloticus and Tilapia zillii and white sturgeon Acipenser transmontanus, under baseline conditions, were low (<4%) for each species, and yet higher than human values (<1%). MetHb results for a given fish species varied significantly between assays and two assays were deemed unacceptable for particular animals. For rainbow trout, white sturgeon, and the two species of tilapia, the Dubowski method gave uncharacteristically high estimates of metHb. MetHb could not measured in tilapia blood using the Evelyn & Malloy method due to spectral interference. Only the Horecker & Brackett assay worked well for all species. Storage conditions were extremely important in the quantification of metHb in rainbow trout blood. For consistent values, samples can be stored up to 4 h on ice (0 degrees C) or at least 20 days under liquid nitrogen (-196 degrees C). Auto-oxidation, however, elevates rainbow trout metHb at -20 and -80 degrees C. It should not be assumed that the blood of fishes and humans perform similarly during assays of metHb.

  18. Quantitative measurements of cerebral blood flow in volume imaging PET scanners

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.J.; Shao, L.; Freifelder, R.; Karp, J.S.; Ragland, J.D. [Univ. of Pennsylvania, Philadelphia, PA (United States)

    1995-08-01

    Quantitative measurements of Cerebral Blood Flow (CBF) are performed in a volume imaging PET Scanner by means of moderate activity infusions. In equilibrium infusions, activations are measured by scanning over 10 minutes with 16 minute activations. Typical measured whole brain CBF values are 37{+-}8 ml/min/100g, close to the value of 42 ml/min/100g reported by other groups using this method. For ramped infusions, scanning over 4 minutes with 5 minute activations results in whole brain CBFs of 49 {+-} 9 ml/min/100g, close to the Kety and Schmidt value of 50 ml/min/100g. Both equilibrium and ramped infusion methods have been used to study face and word memory in human subjects. Both methods were able to detect significant activations in regions implicated in human memory. The authors conclude that precise quantitation of regional CBF is achieved using both methods, and that ramped infusions also provide accurate measures of CBF. In addition a simplified protocol for ramped infusion studies has been developed. In this method the whole brain tissue time activity curve generated from dynamic scanning is replaced by an appropriately scaled camera coincidence countrate curve. The resulting whole brain CBF values are only 7% different from the dynamic scan and fit results. Regional CBFs (rCBF) may then be generated from the summed image (4.25 minutes) using a count density vs flow lookup table.

  19. Lack of correlation of glucose levels in filtered blood plasma to density and conductivity measurements.

    Science.gov (United States)

    Gordon, David M; Ash, Stephen R

    2009-01-01

    The purpose of this research project was to determine whether the glucose level of a blood plasma sample from a diabetic patient could be predicted by measuring the density and conductivity of ultrafiltrate of plasma created by a 30,000 m.w. cutoff membrane. Conductivity of the plasma filtrate measures electrolyte concentration and should correct density measurements for changes in electrolytes and water concentration. In vitro studies were performed measuring conductivity and density of solutions of varying glucose and sodium chloride concentrations. Plasma from seven hospitalized patients with diabetes was filtered across a 30,000 m.w. cutoff membrane. The filtrate density and conductivity were measured and correlated to glucose levels. In vitro studies confirmed the ability to predict glucose from density and conductivity measurements, in varying concentrations of glucose and saline. In plasma filtrate, the conductivity and density measurements of ultrafiltrate allowed estimation of glucose in some patients with diabetes but not others. The correlation coefficient for the combined patient data was 0.45 which was significant but only explained 20% of the variability in the glucose levels. Individually, the correlation was significant in only two of the seven patients with correlation coefficients of 0.79 and 0.88. The reasons for lack of correlation are not clear, and cannot be explained by generation of idiogenic osmoles, effects of alcohol dehydrogenase, water intake, etc. This combination of physical methods for glucose measurement is not a feasible approach to measuring glucose in plasma filtrate.

  20. Retinal hemodynamic oxygen reactivity assessed by perfusion velocity, blood oximetry and vessel diameter measurements

    DEFF Research Database (Denmark)

    Klefter, Oliver Niels; Lauritsen, Anne Øberg; Larsen, Michael

    2015-01-01

    PURPOSE: To test the oxygen reactivity of a fundus photographic method of measuring macular perfusion velocity and to integrate macular perfusion velocities with measurements of retinal vessel diameters and blood oxygen saturation. METHODS: Sixteen eyes in 16 healthy volunteers were studied at two...... examination sessions using motion-contrast velocimetry and retinal oximetry with vessel diameter corrections. To test oxygen reactivity, participants were examined during normoxia, after 15 min of hyperoxia and finally after 45 min of normoxia. Repeatability was assessed by intraclass correlation coefficients...... retinal arterial oxygen saturation from 95.1 ± 5.0% to 96.6 ± 6.4% (p = 0.038) and increased retinal venous oxygen saturation from 62.9 ± 6.7% to 70.3 ± 7.8% (p = 0.0010). Parameters returned to baseline levels after subsequent normoxia. Saturation and vessel diameter ICCs were 0.88-0.98 (range...

  1. NEW METHOD TO MEASURE PISTON SKIRT DIMENSIONS

    Institute of Scientific and Technical Information of China (English)

    Qin Yuexia; Hu Dejin

    2004-01-01

    The measurement of the middle-convex and varying ellipse profile of a piston skirt is a key technology because of its complex profile and high precision. Generally, a piston is measured on special device after it is machined. High accuracy can be achieved through this off-line measurement, but the result diverges from the actual dimension. Therefore, a no-contact in-site measurement system is proposed. A laser displacement meter is used to measure the profile of the piston skirt. A computer connected to the meter is used to process the measured data. A regression analysis method is used to process the ellipse section data. The method of moving average is used to process the middle-convex curve data. By using the given system, high measurement accuracy can be gained, and the production requirement is met.

  2. Ocular Blood Flow Measured Noninvasively in Zero Gravity

    Science.gov (United States)

    Ansari, Rafat R.; Manuel, Francis K.; Geiser, Martial; Moret, Fabrice; Messer, Russell K.; King, James F.; Suh, Kwang I.

    2003-01-01

    In spaceflight or a reduced-gravity environment, bodily fluids shift to the upper extremities of the body. The pressure inside the eye, or intraocular pressure, changes significantly. A significant number of astronauts report changes in visual acuity during orbital flight. To date this remains of unknown etiology. Could choroidal engorgement be the primary mechanism and a change in the curvature or shape of the cornea or lens be the secondary mechanism for this change in visual acuity? Perfused blood flow in the dense meshwork of capillaries of the choroidal tissue (see the preceding illustration) provides necessary nutrients to the outer layers of the retina (photoreceptors) to keep it healthy and maintain good vision. Unlike the vascular system, the choroid has no baroreceptors to autoregulate fluid shifts, so it can remain engorged, pushing the macula forward and causing a hyperopic (farsighted) shift of the eye. Experiments by researchers at the NASA Glenn Research Center could help answer this question and facilitate planning for long-duration missions. We are investigating the effects of zero gravity on the choroidal blood flow of volunteer subjects. This pilot project plans to determine if choroidal blood flow is autoregulated in a reduced-gravity environment.

  3. Comparable application of the OCT and Abbe refractometers for measurements of glycated hemoglobin portion in blood

    Science.gov (United States)

    Zhernovaya, Olga S.; Tuchin, Valery V.; Wang, Ruikang K.

    2006-02-01

    It is known that glucose interacts with plasma proteins and hemoglobin in erythrocytes. Glycated (glycosylated) hemoglobin is the result of an irreversible non-enzymatic fixation of glucose on the beta chain of hemoglobin A. The amount of glycated hemoglobin depends on blood glucose concentration and reflects the mean glycemia of about the previous 2-3 months. Glycated hemoglobin is a useful marker for long-term glucose control in diabetic patients. Therefore, the search of quick and high sensitive methods for measurement of glycated hemoglobin portion in blood is important. This study is focused on the determination of refractive index of hemoglobin solution at different glucose concentrations. Measurements were performed using Abbe refractometer at 589 nm and optical coherence tomography (OCT) at 820 nm. The different amount of glucose (from 0 to 1000 mg/dl with a step 100 mg/dl) was added to hemoglobin solution. Theoretical values of refractive index of hemoglobin solutions with glucose were calculated supposing non-interacting hemoglobin and glucose molecules. There is a difference between measured and calculated values of refractive index. This difference is due to glucose binding to hemoglobin. It is shown that the refractive index measurements can be applied for the evaluation of glycated hemoglobin amount.

  4. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    kept at 10 mmHg during elevation. In these patients, the increase in vascular resistance was significantly less compared with the situation in which venous pressure was 0 mmHg during elevation. The arterial pressure still did not decrease. It is concluded that perfusion pressure in the ischaemic lower......In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...

  5. A new measurement method for ultrasonic surface roughness measurements

    DEFF Research Database (Denmark)

    Forouzbakhsh, Farshid; Rezanejad Gatabi, Javad; Rezanejad Gatabi, Iman

    2008-01-01

    This study proposes the application of Doppler-based ultrasonic method to surface roughness measurements. The fabricated prototype measures the slope of the under-test surface at small holes to evaluate the roughing parameters and this makes for more precise measurement. The device comprises...... at the reflecting point. The relationship between the Doppler shift and the roughing slope is mathematically analyzed. Compared to the transit-time based techniques, the dependency of the sensor on the sound speed in air is decreased by a factor of 2 and therefore a more precise measurement is achieved...

  6. Survey of emissivity measurement by radiometric methods.

    Science.gov (United States)

    Honner, M; Honnerová, P

    2015-02-01

    A survey of the state of the art in the field of spectral directional emissivity measurements by using radiometric methods is presented. Individual quantity types such as spectral, band, or total emissivity are defined. Principles of emissivity measurement by various methods (direct and indirect, and calorimetric and radiometric) are discussed. The paper is focused on direct radiometric methods. An overview of experimental setups is provided, including the design of individual parts such as the applied reference sources of radiation, systems of sample clamping and heating, detection systems, methods for the determination of surface temperature, and procedures for emissivity evaluation.

  7. Coherent methods for measuring ophthalmic surfaces

    Science.gov (United States)

    Rottenkolber, Matthias; Podbielska, Halina

    1996-01-01

    Topographic analysis of the ophthalmic surfaces is an important task. Especially recently, when a laser assisted refractive surgery becomes more and more popular in a daily clinical praxis. Ophthalmologists need to know exact corneal parameters as a basis for proper operational approach, as well as for monitoring of the post-operative process. The fitting of the contact lenses can be more accurate when topography of both, cornea and contacts, can be precisely measured. We develop new coherent methods for measuring of the topography of curved optical surfaces. One of the proposed techniques is based on interferometry with a special distance measurement unit and spatial phase shifting interferogram evaluation. The other one uses deflectometry with spatial carrier frequency. The sensitivity of this method is adjustable and thus it closes the gap between the white light and interferometric measuring methods. The techniques proposed here can be suitable for measurement of the contact lenses or corneal surface.

  8. Residual gravimetric method to measure nebulizer output.

    Science.gov (United States)

    Vecellio None, Laurent; Grimbert, Daniel; Bordenave, Joelle; Benoit, Guy; Furet, Yves; Fauroux, Brigitte; Boissinot, Eric; De Monte, Michele; Lemarié, Etienne; Diot, Patrice

    2004-01-01

    The aim of this study was to assess a residual gravimetric method based on weighing dry filters to measure the aerosol output of nebulizers. This residual gravimetric method was compared to assay methods based on spectrophotometric measurement of terbutaline (Bricanyl, Astra Zeneca, France), high-performance liquid chromatography (HPLC) measurement of tobramycin (Tobi, Chiron, U.S.A.), and electrochemical measurements of NaF (as defined by the European standard). Two breath-enhanced jet nebulizers, one standard jet nebulizer, and one ultrasonic nebulizer were tested. Output produced by the residual gravimetric method was calculated by weighing the filters both before and after aerosol collection and by filter drying corrected by the proportion of drug contained in total solute mass. Output produced by the electrochemical, spectrophotometric, and HPLC methods was determined after assaying the drug extraction filter. The results demonstrated a strong correlation between the residual gravimetric method (x axis) and assay methods (y axis) in terms of drug mass output (y = 1.00 x -0.02, r(2) = 0.99, n = 27). We conclude that a residual gravimetric method based on dry filters, when validated for a particular agent, is an accurate way of measuring aerosol output.

  9. Preanalytical Conditions and DNA Isolation Methods Affect Telomere Length Quantification in Whole Blood.

    Directory of Open Access Journals (Sweden)

    Alexander Tolios

    Full Text Available Telomeres are located at chromosome ends and their length (TL has been associated with aging and human diseases such as cancer. Whole blood DNA is frequently used for TL measurements but the influence of preanalytical conditions and DNA isolation methods on TL quantification has not been thoroughly investigated. To evaluate potential preanalytical as well as methodological bias on TL, anonymized leftover EDTA-whole blood samples were pooled according to leukocyte counts and were incubated with and without actinomycin D to induce apoptosis as a prototype of sample degradation. DNA was isolated from fresh blood pools and after freezing at -80°C. Commercially available kits using beads (Invitrogen, spin columns (Qiagen, Macherey-Nagel and 5prime or precipitation (Stratec/Invisorb and a published isopropanol precipitation protocol (IPP were used for DNA isolation. TL was assessed by qPCR, and normalized to the single copy reference gene 36B4 using two established single-plex and a new multiplex protocol. We show that the method of DNA isolation significantly affected TL (e.g. 1.86-fold longer TL when comparing IPP vs. Invitrogen. Sample degradation led to an average TL decrease of 22% when using all except for one DNA isolation method (5prime. Preanalytical storage conditions did not affect TL with exception of samples that were isolated with the 5prime kit, where a 27% increase in TL was observed after freezing. Finally, performance of the multiplex qPCR protocol was comparable to the single-plex assays, but showed superior time- and cost-effectiveness and required > 80% less DNA. Findings of the current study highlight the need for standardization of whole blood processing and DNA isolation in clinical study settings to avoid preanalytical bias of TL quantification and show that multiplex assays may improve TL/SCG measurements.

  10. Validation of the Use of Dried Blood Spot (DBS Method to Assess Vitamin A Status

    Directory of Open Access Journals (Sweden)

    Elham Fallah

    2012-12-01

    Full Text Available Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne-cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS method in screening the deficient populations. The validity of this method for retinol measurement was investigated.Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci-sion was calculated and compared with those of plasma using F-test. The agreement was eva-luated using Bland-Altman plot.Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma. A good correlation coefficient (r2=0.78 was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P < 0.01. Paired t-test showed no significant difference between the DBS and retinol methods on a group level. Imprecision of DBS measurement was acceptable, compared to that of the plasma method. The difference be-tween these two methods was not statistically significant on a group level.Conclusion: Application of DBS standard samples, in which a part of the plasma was replaced with the artificial plasma, was shown to be a reliable calibration mean for retinol measurements in DBS samples. Retinol in dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma.

  11. Results of kidney function measurement and blood pressure in population from endemic region of Vitina

    Directory of Open Access Journals (Sweden)

    Stašević Zvonimir

    2008-01-01

    Full Text Available Introduction. The analysis of frequency of kidney diseases, causes of terminal renal failure in patients subjected to repeated dialysis in major dialysis centers in the region of Kosovo and Metohija as well as mortality rate in these patients showed a stable number of patients with kidney diseases, evidencing that the populations of Vitina and Gnjilane were the most commonly affected. These towns are designated as regions with the highest incidence of Balkan endemic nephropathy. The present analysis was aimed at: 1. establishing the incidence rate of hypertension and renal function impairment by using clinical and laboratory analyses in individuals from Vitina and neighboring villages, and 2. investigating the correlation between creatinine clearance, age and arterial blood pressure in the studied group. Material and methods. The analysis included 510 individuals (excluding diabetics over the one-month period during 2004 (201 males with their age ranging from 18 to 90 years. Blood pressure measurements were performed in all the individuals, while renal function was determined by glomerular filtration rate (GFR, as calculated according to Cockcroft-Gault formula. Results. Creatinine clearance was lower than 100 ml/min in 237 (46.5% individuals, out of whom 62 (12% had GFR below 60 ml/min. Among the remaining 273 (53.5% individuals with GFR above 100 ml/min, 68 individuals had GFR above 140 ml/min. The distribution of patients depending on their systolic blood pressure values revealed that systolic blood pressure was lower in 44 subjects and higher in 302 subjects (59%. The correlation test revealed significant association between the studied parameters. The positive correlation between patients' age and kidney function means the higher the age of subjects the lower creatinine clearance value (r=-0.622, p<0.001. The negative correlation of the systolic blood pressure value and kidney function was found, meaning that higher the systolic blood

  12. New ITF measure method based on fringes

    Science.gov (United States)

    Fang, Qiaoran; Liu, Shijie; Gao, Wanrong; Zhou, You; Liu, HuanHuan

    2016-01-01

    With the unprecedented developments of the intense laser and aerospace projects', the interferometer is widely used in detecting middle frequency indicators of the optical elements, which put forward very high request towards the interferometer system transfer function (ITF). Conventionally, the ITF is measured by comparing the power spectra of known phase objects such as high-quality phase step. However, the fabrication of phase step is complex and high-cost, especially in the measurement of large-aperture interferometer. In this paper, a new fringe method is proposed to measure the ITF without additional objects. The frequency was changed by adjusting the number of fringes, and the normalized transfer function value was measured at different frequencies. The ITF value measured by fringe method was consistent with the traditional phase step method, which confirms the feasibility of proposed method. Moreover, the measurement error caused by defocus was analyzed. The proposed method does not require the preparation of a step artifact, which greatly reduces the test cost, and is of great significance to the ITF measurement of large aperture interferometer.

  13. A new method for angular displacement measurement

    Institute of Scientific and Technical Information of China (English)

    Caini Zhang(张彩妮); Xiangzhao Wang(王向朝)

    2003-01-01

    We describe a new method for angular displacement measurements that is based on a Fabry-Perot inter-ferometer. A measurement accuracy of 10-s rad is obtained by use of the sinusoidal phase modulatinginterferometry. Another Fabry-Perot interferometer is used to obtain the key initial angle of incidence.

  14. Contemporary methods of body composition measurement

    DEFF Research Database (Denmark)

    Fosbøl, Marie Ø; Zerahn, Bo

    2015-01-01

    . This review is focused on currently applied methods for in vivo measurement of body composition, including densitometry, bioimpedance analysis, dual-energy X-ray absorptiometry, computed tomography (CT), magnetic resonance techniques and anthropometry. Multicompartment models including quantification of trace......Reliable and valid body composition assessment is important in both clinical and research settings. A multitude of methods and techniques for body composition measurement exist, all with inherent problems, whether in measurement methodology or in the assumptions upon which they are based...... elements by in vivo neutron activation analysis, which are regarded as gold standard methods, are also summarized. The choice of a specific method or combination of methods for a particular study depends on various considerations including accuracy, precision, subject acceptability, convenience, cost...

  15. 75 FR 22813 - Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred Because of...

    Science.gov (United States)

    2010-04-30

    ...The Food and Drug Administration (FDA) is announcing the availability of a document entitled ``Guidance for Industry: Requalification Method for Reentry of Blood Donors Deferred Because of Reactive Test Results for Antibody to Hepatitis B Core Antigen (Anti- HBc),'' dated May 2010. The guidance document provides recommendations to establishments that collect Whole Blood or blood components......

  16. New method for the selective labeling of erythrocytes in whole blood with Tc-99m

    Science.gov (United States)

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1984-01-27

    Method and kit are described for the preparation of /sup 99m/Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  17. Thirty years of research on diagnostic and therapeutic thresholds for the self-measured blood pressure at home.

    NARCIS (Netherlands)

    Staessen, J.A.; Thijs, L.; Ohkubo, T.; Kikuya, M.; Richart, T.; Boggia, J.; Adiyaman, A.; Dechering, D.G.; Kuznetsova, T.; Thien, Th.; Leeuw, P de; Imai, Y.; O'brien, E.; Parati, G.

    2008-01-01

    OBJECTIVE: The goal of this review study is to summarize 30 years of research on cut-off limits for the self-measured blood pressure. METHODS: We reviewed two meta-analyses, several prospective outcome studies in populations and hypertensive patients, studies in pregnant women, three clinical trials

  18. Effect of self-measurement of blood pressure on adherence to treatment in patients with mild-to-moderate hypertension.

    NARCIS (Netherlands)

    Onzenoort, H.A.W. van; Verberk, W.J.; Kroon, A.A.; Kessels, A.G.; Nelemans, P.J.; Kuy, P.H. van der; Neef, C.; Leeuw, P.W. de

    2010-01-01

    BACKGROUND: Poor adherence to treatment is one of the major problems in the treatment of hypertension. Self blood pressure measurement may help patients to improve their adherence to treatment. METHOD: In this prospective, randomized, controlled study coordinated by a university hospital, a total of

  19. A quantitative MRI method for imaging blood-brain barrier leakage in experimental traumatic brain injury.

    Directory of Open Access Journals (Sweden)

    Wei Li

    Full Text Available Blood-brain barrier (BBB disruption is common following traumatic brain injury (TBI. Dynamic contrast enhanced (DCE MRI can longitudinally measure the transport coefficient Ktrans which reflects BBB permeability. Ktrans measurements however are not widely used in TBI research because it is generally considered to be noisy and possesses low spatial resolution. We improved spatiotemporal resolution and signal sensitivity of Ktrans MRI in rats by using a high-sensitivity surface transceiver coil. To overcome the signal drop off profile of the surface coil, a pre-scan module was used to map the flip angle (B1 field and magnetization (M0 distributions. A series of T1-weighted gradient echo images were acquired and fitted to the extended Kety model with reversible or irreversible leakage, and the best model was selected using F-statistics. We applied this method to study the rat brain one hour following controlled cortical impact (mild to moderate TBI, and observed clear depiction of the BBB damage around the impact regions, which matched that outlined by Evans Blue extravasation. Unlike the relatively uniform T2 contrast showing cerebral edema, Ktrans shows a pronounced heterogeneous spatial profile in and around the impact regions, displaying a nonlinear relationship with T2. This improved Ktrans MRI method is also compatible with the use of high-sensitivity surface coil and the high-contrast two-coil arterial spin-labeling method for cerebral blood flow measurement, enabling more comprehensive investigation of the pathophysiology in TBI.

  20. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    Energy Technology Data Exchange (ETDEWEB)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S. (Departments of Anaesthesiology, Obstetrics and Gynaecology and Medical Physics, Karolinska Institute at Huddinge University Hospital, Stockholm (Sweden))

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author).

  1. Measurement of human blood viscosity by an electromagnetic spinning sphere viscometer.

    Science.gov (United States)

    Furukawa, Koji; Abumiya, Takeo; Sakai, Keiji; Hirano, Miki; Osanai, Toshiya; Shichinohe, Hideo; Nakayama, Naoki; Kazumata, Ken; Aida, Toshimitsu; Houkin, Kiyohiro

    2016-08-01

    We herein applied an electromagnetic spinning sphere (EMS) viscometer to the measurement of human blood viscosity for the first time. We collected blood samples from 100 healthy outpatient volunteers in order to analyse viscosity dependence on blood cell parameters and on the shear rate with a simple approximation formula [ηi (γ)\\, = Ai γ(- pi) + η0]. Viscosity dependence on blood cell parameters was relatively high at a high shear rate, but became lower as the shear rate decreased. The approximation formula with appropriate parameters of Ai and pi nearly faithfully reproduced actual blood rheological behaviour with a standard deviation of 1.5%. The distributions of Ai and pi values were broad, suggesting that the pattern of viscosity dependence on the shear rate varied with individual differences. The results obtained using the EMS viscometer suggest that blood viscosity values are individual-specific and actual individual measurements are important for understanding rheological conditions.

  2. A New Method to Measure Vaginal Sensibility

    NARCIS (Netherlands)

    Lakeman, M. M. E.; Laan, E.; Vaart, C. H.; Roovers, J. P.

    2010-01-01

    Introduction: Vaginal surgery may affect sexual function both positively and negatively. Possibly, negative consequences of surgical interventions on sexuality may be caused by reduced sensibility of the vaginal wall. Aims: To develop a new method to measure vaginal sensibility. Methods: We develope

  3. Deformability measurement of red blood cells using a microfluidic channel array and an air cavity in a driving syringe with high throughput and precise detection of subpopulations.

    Science.gov (United States)

    Kang, Yang Jun; Ha, Young-Ran; Lee, Sang-Joon

    2016-01-07

    Red blood cell (RBC) deformability has been considered a potential biomarker for monitoring pathological disorders. High throughput and detection of subpopulations in RBCs are essential in the measurement of RBC deformability. In this paper, we propose a new method to measure RBC deformability by evaluating temporal variations in the average velocity of blood flow and image intensity of successively clogged RBCs in the microfluidic channel array for specific time durations. In addition, to effectively detect differences in subpopulations of RBCs, an air compliance effect is employed by adding an air cavity into a disposable syringe. The syringe was equally filled with a blood sample (V(blood) = 0.3 mL, hematocrit = 50%) and air (V(air) = 0.3 mL). Owing to the air compliance effect, blood flow in the microfluidic device behaved transiently depending on the fluidic resistance in the microfluidic device. Based on the transient behaviors of blood flows, the deformability of RBCs is quantified by evaluating three representative parameters, namely, minimum value of the average velocity of blood flow, clogging index, and delivered blood volume. The proposed method was applied to measure the deformability of blood samples consisting of homogeneous RBCs fixed with four different concentrations of glutaraldehyde solution (0%-0.23%). The proposed method was also employed to evaluate the deformability of blood samples partially mixed with normal RBCs and hardened RBCs. Thereafter, the deformability of RBCs infected by human malaria parasite Plasmodium falciparum was measured. As a result, the three parameters significantly varied, depending on the degree of deformability. In addition, the deformability measurement of blood samples was successfully completed in a short time (∼10 min). Therefore, the proposed method has significant potential in deformability measurement of blood samples containing hematological diseases with high throughput and precise detection of

  4. Measurements Of Coronary Mean Transit Time And Myocardial Tissue Blood Flow By Deconvolution Of Intravasal Tracer Dilution Curves

    Science.gov (United States)

    Korb, H.; Hoeft, A.; Hellige, G.

    1984-10-01

    Previous studies have shown that intramyocardial blood volume does not vary to a major extent even during extreme variation of hemodynamics and coronary vascular tone. Based on a constant intramyocardial blood volume it is therefore possible to calculate tissue blood flow from the mean transit time of an intravascular tracer. The purpose of this study was to develop a clinically applicable method for measurement of coronary blood flow. The new method was based on indocyanine green, a dye which is bound to albumin and intravasally detectable by means of a fiberoptic catheter device. One fiberoptic catheter was placed in the aortic root and another in the coronary sinus. After central venous dye injection the resulting arterial and coronary venous dye dilution curves were processed on-line by a micro-computer. The mean transit time as well as myocardial blood flow were calculated from the step response function of the deconvoluted arterial and coronary venous signals. Reference flow was determined with an extracorporeal electromagnetic flowprobe within a coronary sinus bypass system. 38 steady states with coronary blood flow ranging from 49 - 333 ml/min*100g were analysed in 5 dogs. Mean transit times varied from 2.9 to 16.6 sec. An average intracoronary blood volume of 13.9 -7 1.8 m1/100g was calculated. The correlation between flow determined by the dye dilution technique and flow measured with the reference method was 0.98. According to these results determination of coronary blood flow with a double fiberoptic system and indocyanine green should be possible even under clinical conditions. Furthermore, the arterial and coronary venous oxygen saturation can be monitored continuously by the fiberoptic catheters. Therefore, additional information about the performance of the heart such as myocardial oxygen consumption and myocardial efficiency is available with the same equipment.

  5. COMPARATIVE STUDY OF GLUCOMETER AND LABORATORY GLUCOSE OXIDASE METHOD FOR THE ESTIMATION OF BLOOD GLUCOSE LEVELS IN NEONATES

    Directory of Open Access Journals (Sweden)

    Harish

    2015-02-01

    Full Text Available INTRODUCTION : Hypoglycemia is one of the most common metabolic problems encountered in neonates. Hypoglycemia in neonates can be symptomatic and asymptomatic. Hypoglycemia is known to be associated with brain dysfunction and neuromotor developmental retardation. The gl ucose oxidase method used in the laboratory for determining the blood glucose concentration is precise and specific for glucose. As it is usually performed in the main laboratory, the results are not available quickly enough for timely appropriate manageme nt. The glucometers are often used for blood glucose estimation in NICU. Many studies have shown that their results co - relate well with the laboratory measured glucose levels in the normoglycemic and hyperglycemic range but are not satisfactory in the lowe r range. OBJECTIVES: This is a prospective study done to determine the efficacy of glucometer in estimation of blood glucose levels in neonates in comparison with the laboratory values. METHOD S : 250 neonates admitted in NICU, KIMS hospital, Bangalore with varied symptomatology were enrolled in this study. Blood glucose estimation was done by glucometer and laboratory method using the same venous sample at the time of admission. For the last 50 cases glucometer estimation of capillary blood was also done. St atistical analysis was done by using Pearson correlation. Hypoglycemia was defined as blood glucose level 45mg%[0.756] and when the value is <45mg%, there is just a moderate correlation[0.417] . Though the pick - up rate of hypoglycemia by venous blood glucometer [28%] was slightly better compared to the capillary blood glucometer value [22%] , the overa ll pick - up rate of hypoglycemia by glucometer is very low compared to the laboratory method [56%]. CONCLUSION : The glucometer as a sole measuring device to screen neonatal hypoglycemia is not satisfactory and confirmation with the laboratory measurements o f plasma glucose is still of up most importance.

  6. [Influence of some anesthesiologic methods on blood loss in procedures for voluntary termination of pregnancy].

    Science.gov (United States)

    Venuti, F S; Granese, D; Fattori, A

    1980-03-01

    120 patients in good health, aged 25-38, all in the first trimester of pregnancy, and requesting interruption of pregnancy, were divided into 4 groups and given different types of anesthesia; 1) general anesthesia with volatile anesthetics; 2) general anesthesia without volatile anesthetics; 3) dissociated anesthesia with Ketamin; and, 4) paracervical block with Mepivacain 1%. All interventions were done through curettage, and lasted 7-18 minutes; in all cases blood loss was carefully collected and measured. Minimum amount of bleeding was noted with paracervical block; maximum amount with volatile anesthetics such as ethrane. For every type of anesthesia blood loss increased with age of pregnancy. There were no postoperative complications. As confirmed by the published literature anesthesia by paracervical block is an easy, uncomplicated method, which requires little preparation time and which can be done at low cost.

  7. Heat-washout measurements compared to distal blood pressure and perfusion in orthopaedic patients with foot ulcers

    DEFF Research Database (Denmark)

    Midttun, M; Azad, B B S; Broholm, R

    2015-01-01

    Distal blood pressure and local skin perfusion pressure were compared to measurement of blood flow rate (BFR) measured by the heat-washout method in orthopaedic patients with and without diabetes, all with a foot ulcer in one foot, compared to healthy controls. The correlation was good between heat......-washout and distal blood pressure in patients with diabetes with and without an ulcer (P = 0·024 and 0·059, respectively). The correlation was weak in patients without diabetes with and without an ulcer, most probably due to power problems (P = 0·118 and 0·116, respectively). The correlation in the healthy controls...... the surrounding tissue, and therefore, measurements are easier made in these subjects. BFR in the first toe increased significantly in all patients when the foot was moved from heart level to 50 cm below heart level (P = between 0·03 and 0·05) as previously seen in patients with claudication...

  8. Continuous recording of cerebral blood flow by means of a thermal diffusion method using a Peltier stack.

    Science.gov (United States)

    Koshu, K; Hirota, S; Sonobe, M; Takahashi, S; Takaku, A; Saito, T; Ushijima, T

    1987-11-01

    The thermal diffusion method is known to be effective for making quantitative measurements of blood flow, but cannot be easily applied to problems concerning quantitative changes in blood flow. Carter et al. found that the thermal diffusion technique using a Peltier stack as the probe produced extremely stable recordings and was suitable for quantitative work. We made a more stable probe containing an air space and having a stainless cap that added weight. A stable recording of blood flow was then possible. For calibration of the probe, we used blood flow values measured by means of an electrolytic technique and the equation proposed by Carter et al. In the present study, we have shown that it is theoretically possible to perform the calibration even without obtaining data on blood flow after cardiac arrest. Experimentally, the validity of such calibration was confirmed. This technique for measuring blood flow should be applicable in various fields and its use in a clinical setting, particularly in the monitoring of blood flow during neurosurgical operations, can be expected.

  9. COMPANY PERFORMANCE MEASUREMENT AND REPORTING METHODS

    Directory of Open Access Journals (Sweden)

    Nicu Ioana Elena

    2012-12-01

    Full Text Available One of the priorities of economic research has been and remains the re-evaluation of the notion of performance and especially exploring and finding some indicators that would reflect as accurately as possible the subtleties of the economic entity. The main purpose of this paper is to highlight the main company performance measurement and reporting methods. Performance is a concept that raises many question marks concerning the most accurate or the best method of reporting the performance at the company level. The research methodology has aimed at studying the Romanian and foreign specialized literature dealing with the analyzed field, studying magazines specialized on company performance measurement. If the financial performance measurement indicators are considered to offer an accurate image of the situation of the company, the modern approach through non-financial indicators offers a new perspective upon performance measurement, which is based on simplicity. In conclusion, after the theoretical study, I have noticed that the methods of performance measurement, reporting and interpretation are various, the opinions regarding the best performance measurement methods are contradictive and the companies prefer resorting to financial indicators that still play a more important role in the consolidation of the company performance measurement than the non-financial indicators do.

  10. Capacitance Measurement Methods for Integrated Sensor Applications

    Directory of Open Access Journals (Sweden)

    Alireza Hassanzadeh

    2013-09-01

    Full Text Available In this paper different measurement methods that have been used for integrated capacitance measurement are reviewed and their advantage and disadvantages are discussed. For the designers of high accuracy on chip integrated circuits for capacitive sensors, it is important to know which method will provide the best approach for high accuracy, small chip area and power consumption especially for array sensors. These methods include on chip capacitive sensor and transducer measurement techniques that have been implemented for low value capacitance evaluations using CMOS technology. After the best structure is known the designer can optimize the chip for specific application. Voltage mode and current mode, linear and switched mode techniques are reviewed and a useful comparison table comparing all figures of merit including accuracy, range of measurement, chip area, speed and complexity is provided. The provided comparison table can be used as a reference for analog designers in the design of high accuracy integrated capacitive sensor interface

  11. Data Fusion Method for Manufacturing Measurement

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A data fusion method of online multisensors is prop os ed in this paper based on artificial neuron. First, the dynamic data fusion mode l on artificial neuron is built. Then the calibration of data fusion is discusse d with self-adaptive weighing technique. Finally performance of the method is d emonstrated by an online vibration measurement case. The results show that the f used data are more stable, sensitive, accurate, reliable than that of single sen sor data.Data Fusion Method for Manufacturing Measure...

  12. A new method of constructing measure

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    By using a well known result in combinatorics, named K(o)nig Lemma, this paper generalized the method of constructing measure by repeated subdivision, which was a basic tool for fractal geometry. A more general method was presented to construct measure, which was an essential improvement to the existing result. The proof employed a skill similar to that for K(o)nig Lemma, which helped to avoid using the compactness in Euclidean space. Two conditions of the existing method were found not necessary.

  13. Torsion method for measuring piezooptic coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Skab, I.; Smaga, I.; Savaryn, V.; Vasylkiv, Yu.; Vlokh, R. [Institute of Physical Optics, Lviv (Ukraine)

    2011-01-15

    We develop and describe analytically a torsion method for measuring piezooptic coefficients associated with shear stresses. It is shown that the method enables to increase significantly the accuracy of determination of piezooptic coefficients. The method and the appropriate apparatus are verified experimentally on the example of LiNbO{sub 3} crystals. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  14. Integration of optical measurement methods with flight parameter measurement systems

    Science.gov (United States)

    Kopecki, Grzegorz; Rzucidlo, Pawel

    2016-05-01

    During the AIM (advanced in-flight measurement techniques) and AIM2 projects, innovative modern techniques were developed. The purpose of the AIM project was to develop optical measurement techniques dedicated for flight tests. Such methods give information about aircraft elements deformation, thermal loads or pressure distribution, etc. In AIM2 the development of optical methods for flight testing was continued. In particular, this project aimed at the development of methods that could be easily applied in flight tests in an industrial setting. Another equally important task was to guarantee the synchronization of the classical measuring system with cameras. The PW-6U glider used in flight tests was provided by the Rzeszów University of Technology. The glider had all the equipment necessary for testing the IPCT (image pattern correlation technique) and IRT (infrared thermometry) methods. Additionally, equipment adequate for the measurement of typical flight parameters, registration and analysis has been developed. This article describes the designed system, as well as presenting the system’s application during flight tests. Additionally, the results obtained in flight tests show certain limitations of the IRT method as applied.

  15. New method for measuring the thermal conductivity.

    Science.gov (United States)

    Goldratt, E; Greenfield, A J

    1978-11-01

    A new experimental method is presented for measuring the thermal conductivity as a function of temperature. The basic innovation lies in extracting from the measured temperature profile of a sample in vacuo, the thermal conductivity of each individual cross-sectional sample element. The estimated experimental error is +/-1%. Not only is high accuracy achieved, but also a self-checking procedure offers the possibility of avoiding systematic errors. Measurements on two samples of type 304 stainless steel are presented. Three independent sets of measurements give consistent values for the thermal conductivity to well within the estimated error of +/-1%.

  16. Combination of measurements and the BLUE method

    CERN Document Server

    Lista, Luca

    2016-01-01

    The most accurate method to combine measurement from different experiments is to build a combined likelihood function and use it to perform the desired inference. This is not always possible for various reasons, hence approximate methods are often convenient. Among those, the best linear unbiased estimator (BLUE) is the most popular, allowing to take into account individual uncertainties and their correlations. The method is unbiased by construction if the true uncertainties and their correlations are known, but it may exhibit a bias if uncertainty estimates are used in place of the true ones, in particular if those estimated uncertainties depend on measured values. In those cases, an iterative application of the BLUE method may reduce the bias of the combined measurement.

  17. Anxiety and cerebral blood flow during behavioral challenge. Dissociation of central from peripheral and subjective measures

    Energy Technology Data Exchange (ETDEWEB)

    Zohar, J.; Insel, T.R.; Berman, K.F.; Foa, E.B.; Hill, J.L.; Weinberger, D.R.

    1989-06-01

    To investigate the relationship between anxiety and regional cerebral blood flow, we administered behavioral challenges to 10 patients with obsessive-compulsive disorder while measuring regional cerebral blood flow with the xenon 133 inhalation technique. Each patient was studied under three conditions: relaxation, imaginal flooding, and in vivo (actual) exposure to the phobic stimulus. Subjective anxiety, obsessive-compulsive ratings, and autonomic measures (heart rate, blood pressure) increased significantly, but respiratory rate and PCO/sub 2/ did not change across the three conditions. Regional cerebral blood flow increased slightly (in the temporal region) during imaginal flooding, but decreased markedly in several cortical regions during in vivo exposure, when anxiety was highest by subjective and peripheral autonomic measures. These results demonstrate that intense anxiety can be associated with decreased rather than increased cortical perfusion and that ostensibly related states of anxiety (eg, anticipatory and obsessional anxiety) may be associated with opposite effects on regional cerebral blood flow.

  18. A simple trapping method to estimate abundances of blood-sucking flying insects in avian nests

    NARCIS (Netherlands)

    Tomás, G.; Merino, S.; Martínez-de la Puente, J.; Moreno, J.; Morales, J.; Lobato, E.

    2008-01-01

    [KEYWORDS: birds; biting midges; blackflies; blood parasite-insect vector-vertebrate host relationships; Ceratopogonidae; Culicoides; distance to water sources; insecticide treatment; sampling methods; Simuliidae

  19. ETAAS method for the determination of Cd, Cr, Cu, Mn and Se in blood fractions and whole blood

    Energy Technology Data Exchange (ETDEWEB)

    Prohaska, C.; Pomazal, K.; Steffan, I. [Technische Univ., Vienna (Austria). Inst. fuer Analytische Chemie

    2000-11-01

    An electrothermal atomic absorption method (ETAAS) for the direct determination of trace elements (Cd, Cr, Cu, Mn, Se) both in blood fractions (erythrocytes, plasma and lymphocytes) and whole blood was developed. Zeeman background correction and graphite tubes with L'vov platforms were used. Samples were diluted with HNO{sub 3}/Triton X-100 and pipetted directly into the graphite tube. Ashing, pretreatment and atomization steps were optimized carefully for the different fractions and elements applying different matrix modifiers for each element. For the lymphocyte fraction a multi-fold injection technique was applied. Low detection limits of the ETAAS method (Cd 0.13 {mu}g/L, Cr 0.11 {mu}g/L, Cu 0.52 {mu}g/L, Mn 0.13 {mu}g/L, Se 0.7 {mu}g/L of whole blood) combined with small quantities of sample necessary for analysis allow determination of trace elements in this matrix. Verification of possible differences in the trace element status of humans was performed with statistical significance (P < 0.05). In addition, a contribution to the determination of normal values of essential elements was achieved. The method was applied for determination of trace elements in human blood and blood fractions of two groups (n = 50) different in health status. (orig.)

  20. Phase-Contrast Magnetic Resonance Angiography Measurements of Global Cerebral Blood Flow in the Neonate

    NARCIS (Netherlands)

    Benders, Manon J. N. L.; Hendrikse, Jeroen; de Vries, Linda S.; van Bel, Frank; Groenendaal, Floris

    2011-01-01

    Cerebral blood flow (CBF) alterations are important in pathogenesis of neonatal ischemic/hemorrhagic brain damage. In clinical practice, estimation of neonatal CBF is mostly based on Doppler-measured blood flow velocities in major intracranial arteries. Using phase-contrast magnetic resonance angiog

  1. A SEMICONDUCTOR-LASER USED FOR DIRECT MEASUREMENT OF THE BLOOD PERFUSION OF TISSUE

    NARCIS (Netherlands)

    DEMUL, FFM; KOELINK, MH; WEIJERS, AL; GREVE, J; AARNOUDSE, JG; GRAAFF, R; DASSEL, ACM

    1993-01-01

    An instrument consisting merely of a semiconductor laser in its own housing was used to measure the blood perfusion in tissue. Use is made of the feedback of Doppler-scattered light to the photodiode in the laser housing. A recording perfusion of a finger under occlusion of blood flow in the arm is

  2. Lack of reproducibility of linkage results in serially measured blood pressure data

    NARCIS (Netherlands)

    Patel, [No Value; Celedon, JC; Weiss, ST; Palmer, LJ

    2003-01-01

    Background: Using the longitudinal Framingham Heart Study data on blood pressure, we analyzed the reproducibility of linkage measures from serial cross-sectional surveys of a defined population by performing genome-wide model-free linkage analyses to systolic blood pressure (SBP) and history of hype

  3. Numerical methods for simulating blood flow at macro, micro, and multi scales.

    Science.gov (United States)

    Imai, Yohsuke; Omori, Toshihiro; Shimogonya, Yuji; Yamaguchi, Takami; Ishikawa, Takuji

    2016-07-26

    In the past decade, numerical methods for the computational biomechanics of blood flow have progressed to overcome difficulties in diverse applications from cellular to organ scales. Such numerical methods may be classified by the type of computational mesh used for the fluid domain, into fixed mesh methods, moving mesh (boundary-fitted mesh) methods, and mesh-free methods. The type of computational mesh used is closely related to the characteristics of each method. We herein provide an overview of numerical methods recently used to simulate blood flow at macro and micro scales, with a focus on computational meshes. We also discuss recent progress in the multi-scale modeling of blood flow.

  4. A reconstruction method of intra-ventricular blood flow using color flow ultrasound: a simulation study

    Science.gov (United States)

    Jang, Jaeseong; Ahn, Chi Young; Jeon, Kiwan; Choi, Jung-il; Lee, Changhoon; Seo, Jin Keun

    2015-03-01

    A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color Doppler echocardiography measurement. From 3D incompressible Navier- Stokes equation, a 2D incompressible Navier-Stokes equation with a mass source term is derived to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. For demonstrating a feasibility of the proposed method, we have performed numerical simulations of the forward problem and numerical analysis of the reconstruction method. First, we construct a 3D moving LV region having a specific stroke volume. To obtain synthetic intra-ventricular flows, we performed a numerical simulation of the forward problem of Navier-Stokes equation inside the 3D moving LV, computed 3D intra-ventricular velocity fields as a solution of the forward problem, projected the 3D velocity fields on the imaging plane and took the inner product of the 2D velocity fields on the imaging plane and scanline directional velocity fields for synthetic scanline directional projected velocity at each position. The proposed method utilized the 2D synthetic projected velocity data for reconstructing LV blood flow. By computing the difference between synthetic flow and reconstructed flow fields, we obtained the averaged point-wise errors of 0.06 m/s and 0.02 m/s for u- and v-components, respectively.

  5. A Rapid and Low-Cost Nonlithographic Method to Fabricate Biomedical Microdevices for Blood Flow Analysis

    Directory of Open Access Journals (Sweden)

    Elmano Pinto

    2014-12-01

    Full Text Available Microfluidic devices are electrical/mechanical systems that offer the ability to work with minimal sample volumes, short reactions times, and have the possibility to perform massive parallel operations. An important application of microfluidics is blood rheology in microdevices, which has played a key role in recent developments of lab-on-chip devices for blood sampling and analysis. The most popular and traditional method to fabricate these types of devices is the polydimethylsiloxane (PDMS soft lithography technique, which requires molds, usually produced by photolithography. Although the research results are extremely encouraging, the high costs and time involved in the production of molds by photolithography is currently slowing down the development cycle of these types of devices. Here we present a simple, rapid, and low-cost nonlithographic technique to create microfluidic systems for biomedical applications. The results demonstrate the ability of the proposed method to perform cell free layer (CFL measurements and the formation of microbubbles in continuous blood flow.

  6. Clinical application of disposable heparin sensors. Blood heparin measurements during open heart surgery.

    Science.gov (United States)

    Yun, J H; Lee, L M; Wahr, J A; Fu, B; Meyerhoff, M E; Yang, V C

    1995-01-01

    The authors previously reported the development of an ion selective electrode type heparin sensor consisting of a specially formulated polymer membrane doped with tridodecylmethylammonium chloride as the heparin complexing agent. They also demonstrated the feasibility of measuring blood heparin levels by protamine titration, using a disposable copper wire sensor coated with the heparin sensing membrane to probe the titration end point. In this article, the results of further titration studies conducted on 44 clinical whole blood specimens obtained from 8 patients undergoing open heart surgery were reviewed. Samples were taken from patients at four different stages during the bypass surgery: 1) before heparin administration; 2) immediately after heparin administration; 3) within 30 min to 3 hr after heparin administration; and 4) within 30 min after protamine administration. Heparin anticoagulant activity in these samples was monitored by the activated clotting time assay, whereas heparin concentrations were measured by protamine titration using either the Hepcon HMS Titrator (Medtronic HemoTec Inc., Englewood, CO) or the coated wire heparin sensor to determine titration end points. Results indicate that heparin levels determined by the sensor method were in good agreement with those determined by the Hepcon HMS Titrator. When the heparin concentrations estimated by the two methods show significant discrepancy (> 1.0 unit/ml), the sensor method seems to provide more precise values, as verified by an additional chromogenic heparin assay. The overall time required to complete the titration process and heparin measurement with a pre made heparin sensor was less than 3 min. Clinically, the heparin sensor could be used as a safeguard to precisely monitor heparin levels during surgical procedures. Alternatively, the sensor could be used to assess the accurate protamine dose required for full heparin reversal.

  7. The hydrogen gas clearance method for liver blood flow examination: inhalation or local application of hydrogen?

    Science.gov (United States)

    Metzger, H P

    1989-01-01

    The combined method of hydrogen inhalation and local hydrogen production enable the determination of hepatic blood flow (HBF) and local hepatic blood flow (LHBF). LHBF was registered within a small superficial tissue volume of 0.5 mm in diameter by means of a multi-wire electrode having 200 microns producing and 100 microns measuring wires arranged within less than 300 microns distance between the measuring wires. The feeding current for hydrogen production was 1 microA, the potential less than 10 V. The clearance in response to inhalation was registered by means of the same measuring electrodes within the same tissue volume. Spontaneously breathing rats (Wistar-Frömter strain, 180-230 g bw, N = 19, ketamin-xylazine anesthesia, artificial respiration) showed the following flow values: HBF +/- SD = 0.50 +/- 0.26 ml/g.min, n = 48 registrations; LHBF +/- SD = 4.66 +/- 2.13 ml/g.min, n = 43. The validity of the combined method is demonstrated in the LHBF/HBF graph which summarizes the data of hemorrhagic and control animals, m = 0.1 and yo = 0.001. The correlation coefficient of r = 0.685 shows a reasonable correlation of the combined data despite the wide scattering of the individual values.

  8. The EDAPA Project (Education of self-measurement of blood pressure in Grottaglie

    Directory of Open Access Journals (Sweden)

    S. Lenti

    2013-05-01

    Full Text Available AIM OF THE STUDY The EDAPA Project (Education of self-measurement of blood pressure was conceived to train hypertensive patients in self blood pressure monitoring (SBPM and to survey their feedback, including patient’ assessment, by recording their related cardiovascular diseases (CVD risks factors and lifestyle habits. METHODS The project was conducted during the year 2006. Initially we met Grottaglie’s citizens and illustrated to participants the importance of SBPM at home in the overall management of hypertension, that might lead to a better control of BP and cardiovascular outcomes. After explaining the correct technique for SBPM, we distributed semiautomatic devices (OMRON M6 and asked the participants to fill in the Hypertension Questionnaire Form and to record their own blood pressure values in a diary. RESULTS Among almost 3,000 citizens interviewed, 370 (198 M, 172 F; mean age: 60 years agreed to take part in our study. They were hypertensive for almost 10 years, but waited 3 years before beginning therapy. They measured BP 4 times a month and, in the same sitting, 66% of them carried out only 1 measurement, 29% of them 2 measurements and only 2.5% carried out 3 measurements. Taking as reference BP value of 135/85 mmHg, we registered 28% of the population as normotensive and the remaining 72% as hypertensive. Among the hypertensives, 30% showed a good control, 55% showed a bad one and the remaining 15% was not aware of being hypertensive. Adding non-treated hypertensives to those treated but not controlled, we noticed that 70% of the participants was not properly controlled. Regarding risk factors, almost 64% showed hypercholesterolemia; 18% were smokers; 35% of males and 28% of females showed hyperglicemia and 63% of the latter had a waist line > 88 cm; 32% used to consume alcohol (46% males and 15% females; 26% had a metabolic syndrome; 13% was affected by vascular brain injuries, 30% by peripheral artheriopaty, 35% had heart

  9. Noninvasive fluid property measurements using acoustic methods.

    Science.gov (United States)

    Forbush, Michael; Chow, Humphrey; Chiao, James; Rose, Andrew

    2007-03-01

    The properties of a fluid are normally determined using invasive methods. These methods may lead to possibly contaminating or consuming the sample. When only very small amounts of a valuable sample exist, noninvasive measurement methods are preferred. The properties of fluids can then be used to deduce additional properties based on known relationships. In one case, the surface tension of a fluid may be used to determine the concentration of a fluid. The authors describe a measurement technique involving excitation of the surface of the fluid and the measurement of its response. An acoustic wave is used to both excite and monitor the surface of the liquid. This technique is used to determine the concentration of DMSO and water in solution, and the result determines the amount of fluid needed to deliver an accurate amount of solute in solution.

  10. Near-infrared spectroscopy measurement of blood oxygenation content and its application in sports practice

    Science.gov (United States)

    Xu, Guodong; Gong, Hui; Ge, Xinfa; Luo, Qingming

    2003-12-01

    To research the change characteristics of blood oxygenation content in skeletal muscle, the change regularity between blood oxygenation content and exercise intensity as well as HbO2 and blood lactate acid while taking incremental exercises, we took an in vivo, real-time and continuous measurement on the blood oxygenation content of eight sportsmen when they did incremental exercises of five degrees on a power bicycle using a portable tissue oximeter which is based on the principle of near-infrared spectroscopy(NIRS), simultaneously, we detected the blood lactate acid of subjects after each degree of incremental physical load instantly using a blood lactate analysis equipment. The results showed that the content of HbO2 descended regularly while that of Hb ascended; blood volume decreased; and the density of lactate increased as the intensity of exercises was heightened. The statistics analyses showed that the relationship between HbO2 and blood lactate is rather close (correlation coefficient r=-0.918). With this discovery, a theoretical basis in measuring the relative change of blood oxygenation content non-invasively was evidenced, and a novel technology for assessing the physical situation of sportsman, grasping sports density and evaluating the training effect could be imported.

  11. Blood oxygen saturation measured in the presence of a mixture of cyclopropane, sulfur hexafluoride, and ethane.

    Science.gov (United States)

    Forte, V A; Burse, R L; Cymerman, A

    1997-01-01

    Some anesthetic gases interfere with the determination of blood O2 values. We evaluated, for its potential for such interference, a gas mixture containing (v/v) approximately 70% ethane, 20% sulfur hexafluoride, and 10% cyclopropane, as is currently used in trace amounts to determine ventilation-perfusion (v/Q) ratios. Normal human blood samples were first tonometered with control gas mixtures containing (v/v): (1) 20.9% O2, 0.04% CO2; (2) 16.0% O2, 4.0% CO2; and (3) 9.9% O2, 7.8% CO2. A large quantity (20.9%) of the v/Q mixture was blended experimentally into the control mixture and the tonometry repeated. The entire experiment was then repeated substituting pure N2 for the v/Q mixture as a dilution control. O2 values were determined by three methods: (1) a polarographic electrode, ABL-300 (ABL); (2) a spectrophotometric method, Co-Oximeter (COOX); and (3) a galvanic cell, Lex-O2-Con (LEX). The v/Q gas mixture lowered significantly all measured LEX values by 2.5-3.6 saturation percent (sat%), but showed no effect, dilution or otherwise, on the O2 values determined by the COOX and ABL methods. The N2 dilution lowered the LEX values by an average of only 0.9 sat%; the ABL and the COOX were approximately 0.6 sat% lower. We therefore suggest that, if any of these O2 measurement methods are used in the presence of the v/Q mixture, baseline O2 values should be determined both before and after injection of the mixture into the bloodstream, prior to performing other experimental manipulations. The difference between the two values, if any, can then be used to interpret subsequent results.

  12. Doctor Reports New Way to Measure Blood Sugar

    Institute of Scientific and Technical Information of China (English)

    林徽英

    2000-01-01

    对“糖尿病”及其危害,本文有一简略说明: Diabetes occurs when blood sugar,or glucose,a source of body fuel,is toohigh and the body is not able to burn it.The disease can lead to blindness,organdiseases,stroke and death. 句中的一个动词burn令我们过目难忘。此外,此疾引起的后果也令人生畏:blindness,organ diseases,stroke and death. 要测得患者的血糖含量,就得验血,就得像本文所讲的那样“pricking(刺;戳)the skin and drawing a tiny amount of blood”。 美国宾夕法尼亚州立大学的研究人员研制了a hand—held ultrasound(超声波)machine,验血者可免受皮肉之苦,而又可测量到准确的血糖含量。 文章末尾有一条信息:美国人中糖尿病患者约占总人口的6%。

  13. Ghost Cell Suspensions as Blood Analogue Fluid for Macroscopic Particle Image Velocimetry Measurements.

    Science.gov (United States)

    Jansen, Sebastian V; Müller, Indra; Nachtsheim, Max; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2016-02-01

    Spatially resolved measurement of blood flow is of great interest in the development of artificial blood-carrying devices such as blood pumps, heart valve prostheses, and oxygenators. Particle image velocimetry (PIV) is able to measure instantaneous velocity fields in a plane with high accuracy and is being used more frequently for the development of such devices. However, as this measurement technique is based on optical access, blood flow at physiological hematocrit values is difficult to measure due to its low transparency and multiscattering properties. So far, only very small dimensions (in the range of 400 μm) can be measured using PIV. A suspension of ghost cells (GCs) offers a higher optical transparency than blood while having a similar rheological behavior. In this study, a procedure for the production of GC suspensions containing a very low intracellular hemoglobin concentration is presented. With the help of multiple rounds of controlled cell lysis, the intracellular hemoglobin concentration could be decreased to a point where a standard macroscopic PIV measurement was possible. A velocity profile of a 44% GC suspension in a circular channel with a diameter of 9.5 mm was measured with high spatial resolution. Meanwhile, the rheological behavior was found to be comparable with blood.

  14. Comparison of a human portable glucometer and an automated chemistry analyzer for measurement of blood glucose concentration in pet ferrets (Mustela putorius furo)

    OpenAIRE

    Summa, Noémie M.; Eshar, David; Lee-Chow, Bridget; Larrat, Sylvain; Brown, Dorothy C.

    2014-01-01

    This study compared blood glucose concentrations measured with a portable blood glucometer and a validated laboratory analyzer in venous blood samples of 20 pet ferrets (Mustela putorius furo). Correlation and agreement were evaluated with a Bland-Altman plot method and Lin’s concordance correlation coefficient. Blood glucose concentrations measured with the laboratory analyzer and the glucometer ranged from 1.9 to 8.6 mmol/L and from 0.9 to 9.2 mmol/L, respectively. The glucometer had a poor...

  15. Two-temperature method for measuring emissivity

    Science.gov (United States)

    Watson, K.

    1992-01-01

    Spectral emissivity can be uniquely determined from radiance measurements if the object can be observed at two different temperatures. The advantage of this approach is that the spectral emissivity is determined without a priori assumptions about spectral shape. Because the different temperatures are obtained by observing the scene at two times in the diurnal cycle (optimally after midday and midnight), the method assumes that emissivity is temporally invariant. This is valid for rocks and dry soils, not well established for vegetation, and not true when changes in soil moisture occur between the measurements. Accurate image registration and satisfactory signal:noise are critical factors that limit extensive use of this method. ?? 1992.

  16. A simple method for focal length measurement

    Science.gov (United States)

    Ma, Hua; Ren, Huan; Zhang, Lin; Shi, Zhengdong; Yuan, Quan; Yang, Yi

    2016-09-01

    A simple method for focal length measurement based on image processing is demonstrated and discussed. The collimated beam, detector, motorized translation stage and computer make up of this test system. The two spots pass through the tested lens is accepted by detector, which is transferred twice by motorized translation stage. By acquired the difference of two spots by image processing, the focal length of the tested lens can be gained. The error sources in the measurement are analyzed. Then the results of experiment show that the relative error was 0.1%. This method can be used in workshop and labs for its convenience and low cost.

  17. Three methods to measure RH bond energies

    Energy Technology Data Exchange (ETDEWEB)

    Berkowitz, J. [Argonne National Lab., IL (United States); Ellison, G.B. [Univ. of Colorado, Boulder, CO (United States). Dept. of Chemistry and Biochemistry; Gutman, D. [Catholic Univ. of America, Washington, DC (United States). Dept. of Chemistry

    1993-03-21

    In this paper the authors compare and contrast three powerful methods for experimentally measuring bond energies in polyatomic molecules. The methods are: radical kinetics; gas phase acidity cycles; and photoionization mass spectroscopy. The knowledge of the values of bond energies are a basic piece of information to a chemist. Chemical reactions involve the making and breaking of chemical bonds. It has been shown that comparable bonds in polyatomic molecules, compared to the same bonds in radicals, can be significantly different. These bond energies can be measured in terms of bond dissociation energies.

  18. THE USE OF REPEAD MEASUREMENTS METHOD FOR

    Directory of Open Access Journals (Sweden)

    Gürol ZIRHLIOĞLU

    2009-08-01

    Full Text Available The repeated measurements method is used to get information about one or more than one effects of factors by means of repeated experiments in different place, time and materials. In this study, mixed model method related tok repeated measurement is used for the analysis of the Turkish Women’s National Volleyball Team players who participated World Championship which organizated in Japan in 2006 and investigated players perfomance whether changed according to mathces and won points scored. According to the results, it is concluded that significant differences between players’ match performance might be obtained.

  19. Standing orthostatic blood pressure measurements cannot be replaced by sitting measurements.

    Science.gov (United States)

    Breeuwsma, Anna C; Hartog, Laura C; Kamper, Adriaan M; Groenier, Klaas H; Bilo, Henk Jg; Kleefstra, Nanne; Van Hateren, Kornelis Jj

    2017-03-16

    As many elderly patients are not able to stand for several minutes, sitting orthostatic blood pressure (BP) measurements are sometimes used as an alternative. We aimed to investigate the difference in BP response and orthostatic hypotension (OH) prevalence between the standard postural change to the sitting and the standing position in a cross-sectional observational study. BP was measured with a continuous BP measurement device during two postural changes, from supine to the sitting and from supine to the standing position. Linear mixed models were used to investigate the differences in changes (Δ) of systolic BP (SBP) and diastolic BP (DBP) between the two postural changes. The prevalence and the positive and negative proportions of agreement of OH were calculated of the two postural changes. One hundred and four patients with a mean age of 69 years were included. ΔSBP was significantly larger in the standing position compared with the sitting between 0 and 44 s. ΔDBP was significantly larger in the sitting position compared with the standing 75-224 s after postural change. The prevalence of OH was 66.3% (95% confidence interval (CI) 57.2, 75.4) in the standing position and 67.3% (95% CI 58.3, 76.3) in the sitting position. The positive proportion of agreement was 74.8% and the negative proportion of agreement was 49.3%. A clear difference was seen in BP response between the two postural changes. Although no significant difference in prevalence of OH was observed, the positive and negative proportion of agreement of the prevalence of OH were poor to moderate, which indicates a different outcome between both postural changes.Hypertension Research advance online publication, 16 March 2017; doi:10.1038/hr.2017.39.

  20. Advanced Recording and Preprocessing of Physiological Signals. [data processing equipment for flow measurement of blood flow by ultrasonics

    Science.gov (United States)

    Bentley, P. B.

    1975-01-01

    The measurement of the volume flow-rate of blood in an artery or vein requires both an estimate of the flow velocity and its spatial distribution and the corresponding cross-sectional area. Transcutaneous measurements of these parameters can be performed using ultrasonic techniques that are analogous to the measurement of moving objects by use of a radar. Modern digital data recording and preprocessing methods were applied to the measurement of blood-flow velocity by means of the CW Doppler ultrasonic technique. Only the average flow velocity was measured and no distribution or size information was obtained. Evaluations of current flowmeter design and performance, ultrasonic transducer fabrication methods, and other related items are given. The main thrust was the development of effective data-handling and processing methods by application of modern digital techniques. The evaluation resulted in useful improvements in both the flowmeter instrumentation and the ultrasonic transducers. Effective digital processing algorithms that provided enhanced blood-flow measurement accuracy and sensitivity were developed. Block diagrams illustrative of the equipment setup are included.

  1. Rapid method for identification of group B streptococci in neonatal blood cultures.

    OpenAIRE

    Holmes, R. L.; Harada, W A

    1981-01-01

    A rapid technique used for the identification of Streptococcus agalactiae, Lancefield group B, from the blood cultures of two neonatal infants is reported. The method utilized the Phadebact Streptococcus Test System (Pharmacia Diagnostics, Piscataway, N.J.) and the supernatant from 13- and 14-h blood cultures. Additional studies with simulated neonatal blood cultures revealed that this method was reproducible. Additional studies also revealed that some non-specific agglutination did occur, wh...

  2. Cerebral blood flow and intracranial pulsatility studied with MRI: measurement, physiological and pathophysiological aspects

    Energy Technology Data Exchange (ETDEWEB)

    Waahlin, Anders

    2012-07-01

    During each cardiac cycle pulsatile arterial blood inflates the vascular bed of the brain, forcing cerebrospinal fluid (CSF) and venous blood out of the cranium. Excessive arterial pulsatility may be part of a harmful mechanism causing cognitive decline among elderly. Additionally, restricted venous flow from the brain is suggested as the cause of multiple sclerosis. Addressing hypotheses derived from these observations requires accurate and reliable investigational methods. This work focused on assessing the pulsatile waveform of cerebral arterial, venous and CSF flows. The overall aim of this dissertation was to explore cerebral blood flow and intracranial pulsatility using MRI, with respect to measurement, physiological and pathophysiological aspects.Two-dimensional phase contrast magnetic resonance imaging (2D PCMRI) was used to assess the pulsatile waveforms of cerebral arterial, venous and CSF flow. The repeatability was assessed in healthy young subjects. The 2D PCMRI measurements of cerebral arterial, venous and CSF pulsatility were generally repeatable but the pulsatility decreased systematically during the investigation. A method combining 2D PCMRI measurements with invasive CSF infusion tests to determine the magnitude and distribution of compliance within the craniospinal system was developed and applied in a group of healthy elderly. The intracranial space contained approximately two thirds of the total craniospinal compliance. The magnitude of craniospinal compliance was less than suggested in previous studies. The vascular hypothesis for multiple sclerosis was tested. Venous drainage in the internal jugular veins was compared between healthy controls and multiple sclerosis patients using 2D PCMRI. For both groups, a great variability in the internal jugular flow was observed but no pattern specific to multiple sclerosis could be found. Relationships between regional brain volumes and potential biomarkers of intracranial cardiac-related pulsatile

  3. Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration

    Institute of Scientific and Technical Information of China (English)

    Wenliang Chen(陈文亮); Rong Liu(刘蓉); Houxin Cui(崔厚欣); Kexin Xu(徐可欣); Lina Lü(吕丽娜)

    2004-01-01

    In this paper, the propagation characteristics of near-infrared (NIR) light in the palm tissue are analyzed,and the principle and feasibility of using transcutaneous diffuse reflectance spectroscopy for non-invasive blood glucose detection are presented. An optical probe suitable for measuring the diffuse reflectance spectrum of human palm and a non-invasive blood glucose detection system using NIR spectroscopy are designed. Based on this system, oral glucose tolerance tests are performed to measure the blood glucose concentrations of two young healthy volunteers. The partial least square calibration model is then constructed by all individual experimental data. The final result shows that correlation coefficients of the two experiments between the predicted blood glucose concentrations and the reference blood glucose concentrations are 0.9870 and 0.9854, respectively. The root mean square errors of prediction of full cross validation are 0.54 and 0.52 mmol/1, respectively.

  4. Modeling Of Blood Vessel Constriction In 2-D Case Using Molecular Dynamics Method

    CERN Document Server

    Rendi, Mohamad; Viridi, Sparisoma

    2013-01-01

    Blood vessel constriction is simulated with particle-based method using a molecular dynamics authoring software known as Molecular Workbench (WM). Blood flow and vessel wall, the only components considered in constructing a blood vessel, are all represented in particle form with interaction potentials: Lennard-Jones potential, push-pull spring potential, and bending spring potential. Influence of medium or blood plasma is accommodated in plasma viscosity through Stokes drag force. It has been observed that pressure p is increased as constriction c is increased. Leakage of blood vessel starts at 80 % constriction, which shows existence of maximum pressure that can be overcome by vessel wall.

  5. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  6. Performance and Storage Integrity of Dried Blood Spots for PCB, BFR and Pesticide Measurements

    Science.gov (United States)

    Batterman, Stuart; Chernyak, Sergei

    2014-01-01

    Dried blood spots (DBS) can provide accurate and valuable estimates of exposure to environmental toxicants, and the use of information derived from archived newborn DBS information has enormous potential to open up new research on the impacts of early chemical exposure on disease. Broad application of DBS for the purpose of quantitative exposure estimation requires robust and validated methods. This study investigates the suitability of DBS analyses for population studies of exposure to three chemical groups: polychlorinated biphenyls (PCBs), brominated flame retardants (BFRs), and chlorinated pesticides. It examines background (matrix) contamination, recovery and extraction variability, sensitivity, and storage stability. DBS samples prepared using 50 μL of adult blood were analyzed by GC/MS, and method performance was confirmed by using certified materials and paired DBS-blood samples from six volunteers. Several of the target compounds and their degradation products have not been previously measured in DBS. All target compounds were detected in DBS samples collected from the volunteers. Sample DBS cards showed background contamination of several compounds. When stored at room temperature, target compounds, excluding PBDEs, were stable for up to one month. When refrigerated or frozen, stability was acceptable for all compounds up to one year, and multiyear storage appears acceptable at colder (e.g., −80 °C) temperatures. Multicompartment models may be used to estimate or correct for storage losses. Considering concentrations of contaminants for adults and children reported in the literature, and experimental values of detection limits and background contamination, DBS samples are suitable for quantifying exposures to many PCBs, BFRs and persistent pesticides. PMID:25058892

  7. An Automated Method to Quantify Radiation Damage in Human Blood Cells

    Energy Technology Data Exchange (ETDEWEB)

    Gordon K. Livingston, Mark S. Jenkins and Akio A. Awa

    2006-07-10

    Cytogenetic analysis of blood lymphocytes is a well established method to assess the absorbed dose in persons exposed to ionizing radiation. Because mature lymphocytes circulate throughout the body, the dose to these cells is believed to represent the average whole body exposure. Cytogenetic methods measure the incidence of structural aberrations in chromosomes as a means to quantify DNA damage which occurs when ionizing radiation interacts with human tissue. Methods to quantify DNA damage at the chromosomal level vary in complexity and tend to be laborious and time consuming. In a mass casualty scenario involving radiological/nuclear materials, the ability to rapidly triage individuals according to radiation dose is critically important. For high-throughput screening for dicentric chromosomes, many of the data collection steps can be optimized with motorized microscopes coupled to automated slide scanning platforms.

  8. Correlation between objective automatic and auscultatory mercury manometer blood pressure measurements.

    Science.gov (United States)

    Gonzalez Biosca, M D; Fernandez-Cruz, A; Mizushima, S; Yamori, Y

    1990-01-01

    The automatic blood pressure (BP) measurement device (A) developed for the World Health Organization (WHO) Cardiovascular Diseases and Alimentary Comparison (CARDIAC) Study was compared in Spain with the standard auscultatory-mercury manometer (M) in 440 randomly selected subjects, 50-54 years old (50% men and 50% women). BPs were recorded simultaneously in the same arm. Systolic BP (SBP), analyzed in 1,440 readings, was 127.5 +/- 18.9 mm Hg by A system and 127.6 +/- 18.6 mm Hg by M system (NS). Diastolic BP (DBP) was 71.3 +/- 11.7 mm Hg by A and 79.3 +/- 11 mm Hg by M (p less than 0.001). We confirmed good correlations in SBP and DBP measured by both methods (r = 0.95 and r = 0.88, respectively; both p less than 0.001). Nearly complete consistency was noted between SBP readings by both methods but not between DBP readings; the readings by M were significantly higher than those by A. Since A's consistency with SBP and DBP readings obtained by the intra-arterial method (the most commonly used method) previously had been proven to be satisfactory, DBP obtained by clinical practice is possibly overestimated in adults.

  9. Survey of blood cultures methods in Italy in 2010

    Directory of Open Access Journals (Sweden)

    Antonio Goglio

    2011-09-01

    Full Text Available Sepsis is a serious clinical condition, associated with high mortality despite advanced modern medical treatment. Traditionally, the detection and identification of bacteria and fungi circulating in the blood-stream is based on blood cultures. A number of factors influence the yield of blood culture, most of them concerning the microbiologist skill and the laboratory organization. In order to collect information about the practices and procedures used for the detection of microrganisms in blood cultures in the italian laboratory (lab, an e-mail with the invitation to participate in the survey was sent to 2000 members of the Italian Association of Clinical Microbiology. Responses were received from 100 lab, located from all over the country (in 18/20 italian regions. The results presented hereby concern specimen collection, culture techniques, rapid identification and susceptibility testing, laboratory organization, relationships with physicians. In summary, most lab use automated systems (96%, the bottles are incubated immediately during public holidays in 72/96 lab (75% and in 49/97 lab at night (50.5%, the lenght of incubation was 5 or 7 days in 93% of the lab, although it is common to extend the incubation period when brucellosis (74 lab, endocarditis (49 lab, systemic mycosis (33 lab is suspected. A wide variety of media are employed for subcultures. All lab process the positive bottles at least once a day, while only in 42 of 81 (51.9% lab the positive blood are processed on holiday. Communication between clinicians and microbiologist include: distribution of specimen collection guidelines (96/100 lab, availability to microbiologist of patients’ clinical situation (77/96 lab, 80.2%, and adding to report the microbiologist’ suggestion (75/98 lab, 76.5%. The results, compared with those collected with a similar questionnaire in 2001, show a greater adherence to guidelines: the number of bottles examined by lab yearly is almost doubled

  10. Measuring cell surface area and deformability of individual human red blood cells over blood storage using quantitative phase imaging

    Science.gov (United States)

    Park, Hyunjoo; Lee, Sangyun; Ji, Misuk; Kim, Kyoohyun; Son, Yonghak; Jang, Seongsoo; Park, Yongkeun

    2016-10-01

    The functionality and viability of stored human red blood cells (RBCs) is an important clinical issue in transfusions. To systematically investigate changes in stored whole blood, the hematological properties of individual RBCs were quantified in blood samples stored for various periods with and without a preservation solution called citrate phosphate dextrose adenine-1 (CPDA-1). With 3-D quantitative phase imaging techniques, the optical measurements for 3-D refractive index (RI) distributions and membrane fluctuations were done at the individual cell level. From the optical measurements, the morphological (volume, surface area and sphericity), biochemical (hemoglobin content and concentration), and mechanical parameters (dynamic membrane fluctuation) were simultaneously quantified to investigate the functionalities and progressive alterations of stored RBCs. Our results show that stored RBCs without CPDA-1 had a dramatic morphological transformation from discocytes to spherocytes within two weeks which was accompanied by significant decreases in cell deformability and cell surface area, and increases in sphericity. However, the stored RBCs with CPDA-1 maintained their morphology and deformability for up to 6 weeks.

  11. Measurement of capillary blood glucose concentrations by pet owners: a new tool in the management of diabetes mellitus.

    Science.gov (United States)

    Casella, Martina; Wess, Gerhard; Reusch, Claudia E

    2002-01-01

    Recently a new method for capillary blood sampling from the ears of dogs and cats was described, which allows the measurement of glucose concentration by means of portable glucose meters. The authors of this report evaluated the suitability of this method for use by pet owners and the potential technical problems. The owners of seven healthy dogs and seven healthy cats were asked to perform two glucose curves (measuring blood glucose concentration every 2 hours for a total of 12 hours). All dog owners and three cat owners were able to perform a reliable blood glucose curve. The most frequently encountered problems were inadequate formation of a blood drop due to excessive digital pressure on the pinna, repeatedly depressing the plunger of the lancet device instead of allowing the negative pressure to slowly build up, and failure to fill the test strip up to the mark. The authors conclude that these steps of the procedure need to be stressed during technique demonstration and that home monitoring of blood glucose concentrations may serve as a new tool in the management of diabetic dogs and cats.

  12. Measurement of volatile organic compounds in human blood.

    OpenAIRE

    Ashley, D L; Bonin, M A; Cardinali, F L; McCraw, J. M.; Wooten, J V

    1996-01-01

    Volatile organic compounds (VOCs) are an important public health problem throughout the developed world. Many important questions remain to be addressed in assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in the analytical determination of VOCs. The analytical methodology chosen to measure toxicants in biological materials must be well validated and carefully carried out; poor quality assurance can lead to invalid resul...

  13. Estimating mechanical blood trauma in a centrifugal blood pump: laser Doppler anemometer measurements of the mean velocity field.

    Science.gov (United States)

    Pinotti, M; Paone, N

    1996-06-01

    A laser Doppler anemometer (LDA) was used to obtain the mean velocity and the Reynolds stress fields in the inner channels of a well-known centrifugal vaneless pump (Bio-pump). Effects of the excessive flow resistance against which an occlusive pump operates in some surgical situations, such as cardiopulmonary bypass, are illustrated. The velocity vector field obtained from LDA measurements reveals that the constraint-forced vortex provides pumping action in a restricted area in the core of the pump. In such situations, recirculating zones dominate the flow and consequently increase the damage to blood cells and raise the risk of thrombus formation in the device. Reynolds normal and shear stress fields were obtained in the entry flow for the channel formed by two rotating cones to illustrate the effects of flow disturbances on the potential for blood cell damage.

  14. Absolute cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking: comparison with positron emission tomography values

    DEFF Research Database (Denmark)

    Østergaard, Leif; Smith, D F; Vestergaard-Poulsen, Peter;

    1998-01-01

    The authors determined cerebral blood flow (CBF) with magnetic resonance imaging (MRI) of contrast agent bolus passage and compared the results with those obtained by O-15 labeled water (H215O) and positron emission tomography (PET). Six pigs were examined by MRI and PET under normo......- and hypercapnic conditions. After dose normalization and introduction of an empirical constant phi Gd, absolute regional CBF was calculated from MRI. The spatial resolution and the signal-to-noise ratio of CBF measurements by MRI were better than by the H215O-PET protocol. Magnetic resonance imaging cerebral...... blood volume (CBV) estimates obtained using this normalization constant correlated well with values obtained by O-15 labeled carbonmonooxide (C15O) PET. However, PET CBV values were approximately 2.5 times larger than absolute MRI CBV values, supporting the hypothesized sensitivity of MRI to small...

  15. Light extinction method for solubility measurement

    Institute of Scientific and Technical Information of China (English)

    Shui Wang; Jingkang Wang; Qiuxiang Yin; Yongli Wang

    2005-01-01

    A novel measurement method for chemical solubility determination is brought forward, in which the advantages of two kinds of traditional methods are united. The results show that the concentration of unsolved particles suspending in the solution can be determined by measuring I/I0 (ratio of the transmission intensity to the incident intensity) of the laser beam permeating through the solution according to Lamben-Beer law. The biggest relative deviation for the solubility data determined is less than 1.5% for the sparingly soluble substances and 0.3% for the opulently soluble substances. By comparison of the experimental solubility data with previous data, the light extinction method is demonstrated to be stable and reliable.

  16. Bayesian methods for measures of agreement

    CERN Document Server

    Broemeling, Lyle D

    2009-01-01

    Using WinBUGS to implement Bayesian inferences of estimation and testing hypotheses, Bayesian Methods for Measures of Agreement presents useful methods for the design and analysis of agreement studies. It focuses on agreement among the various players in the diagnostic process.The author employs a Bayesian approach to provide statistical inferences based on various models of intra- and interrater agreement. He presents many examples that illustrate the Bayesian mode of reasoning and explains elements of a Bayesian application, including prior information, experimental information, the likelihood function, posterior distribution, and predictive distribution. The appendices provide the necessary theoretical foundation to understand Bayesian methods as well as introduce the fundamentals of programming and executing the WinBUGS software.Taking a Bayesian approach to inference, this hands-on book explores numerous measures of agreement, including the Kappa coefficient, the G coefficient, and intraclass correlation...

  17. Blood Contamination in Saliva: Impact on the Measurement of Salivary Oxidative Stress Markers

    Directory of Open Access Journals (Sweden)

    Natália Kamodyová

    2015-01-01

    Full Text Available Salivary oxidative stress markers represent a promising tool for monitoring of oral diseases. Saliva can often be contaminated by blood, especially in patients with periodontitis. The aim of our study was to examine the impact of blood contamination on the measurement of salivary oxidative stress markers. Saliva samples were collected from 10 healthy volunteers and were artificially contaminated with blood (final concentration 0.001–10%. Next, saliva was collected from 12 gingivitis and 10 control patients before and after dental hygiene treatment. Markers of oxidative stress were measured in all collected saliva samples. Advanced oxidation protein products (AOPP, advanced glycation end products (AGEs, and antioxidant status were changed in 1% blood-contaminated saliva. Salivary AOPP were increased in control and patients after dental treatment (by 45.7% and 34.1%, p<0.01. Salivary AGEs were decreased in patients after microinjury (by 69.3%, p<0.001. Salivary antioxidant status markers were decreased in both control and patients after dental treatment (p<0.05 and p<0.01. One % blood contamination biased concentrations of salivary oxidative stress markers. Saliva samples with 1% blood contamination are visibly discolored and can be excluded from analyses without any specific biochemic detection of blood constituents. Salivary markers of oxidative stress were significantly altered in blood-contaminated saliva in control and patients with gingivitis after dental hygiene treatment.

  18. Four Methods for Calculating Blood-loss after Total Knee Arthroplasty

    Institute of Scientific and Technical Information of China (English)

    Fu-Qiang Gao; Zi-Jian Li; Ke Zhang; Wei Sun; Hong Zhang

    2015-01-01

    Background:Currently,various calculation methods for evaluating blood-loss in patients with total knee arthroplasty (TKA) are applied in clinical practice.However,different methods may yield different results.The purpose of this study was to determine the most reliable method for calculating blood-loss after primary TKA.Methods:We compared blood-loss in 245 patients who underwent primary unilateral TKA from February 2010 to August 2011.We calculated blood-loss using four methods:Gross equation,hemoglobin (Hb) balance,the Orthopedic Surgery Transfusion Hemoglobin European Overview (OSTHEO) formula,and Hb-dilution.We determined Pearson's correlation coefficients for the four methods.Results:There were large differences in the calculated blood-loss obtained by the four methods.In descending order of combined correlation coefficient based on calculated blood-loss,the methods were Hb-balance,OSTHEO formula,Hb-dilution,and Gross equation.Conclusions:The Hb-balance method may be the most reliable method of estimating blood-loss after TKA.

  19. Identification of Phosphoglycerate Kinase 1 (PGK1 as a reference gene for quantitative gene expression measurements in human blood RNA

    Directory of Open Access Journals (Sweden)

    Unger Elizabeth R

    2011-09-01

    gene expression results from blood RNA collected and processed by different methods with the intention of biomarker discovery. Results of this study should facilitate large-scale molecular epidemiologic studies using blood RNA as the target of quantitative gene expression measurements.

  20. Simultaneous blood flow and blood oxygenation measurements using a combination of diffuse speckle contrast analysis and near-infrared spectroscopy

    Science.gov (United States)

    Seong, Myeongsu; Phillips, Zephaniah; Mai, Phuong Minh; Yeo, Chaebeom; Song, Cheol; Lee, Kijoon; Kim, Jae Gwan

    2016-02-01

    A combined diffuse speckle contrast analysis (DSCA)-near-infrared spectroscopy (NIRS) system is proposed to simultaneously measure qualitative blood flow and blood oxygenation changes in human tissue. The system employs an optical switch to alternate two laser sources at two different wavelengths and a CCD camera to capture the speckle image. Therefore, an optical density can be measured from two wavelengths for NIRS measurements and a speckle contrast can be calculated for DSCA measurements. In order to validate the system, a flow phantom test and an arm occlusion protocol for arterial and venous occlusion were performed. Shorter exposure times (<1 ms) show a higher drop (between 50% and 66%) and recovery of 1/KS2 values after occlusion (approximately 150%), but longer exposure time (3 ms) shows more consistent hemodynamic changes. For four subjects, the 1/KS2 values dropped to an average of 82.1±4.0% during the occlusion period and the average recovery of 1/KS2 values after occlusion was 109.1±0.8%. There was also an approximately equivalent amplitude change in oxyhemoglobin (OHb) and deoxyhemoglobin (RHb) during arterial occlusion (max RHb=0.0085±0.0024 mM/DPF, min OHb=-0.0057±0.0044 mM/DPF). The sensitivity of the system makes it a suitable modality to observe qualitative hemodynamic trends during induced physiological changes.

  1. Endoscopic Doppler ultrasound for measurement of azygos blood flow. Validation against thermodilution and assessment of pharmacological effects of terlipressin in portal hypertension

    DEFF Research Database (Denmark)

    Hansen, Erik Feldager; Bendtsen, Flemming; Brinch, K;

    2001-01-01

    BACKGROUND: Endoscopic ultrasound (EUS) is a new modality allowing real-time flow measurements by means of the Doppler technique. The aim of the study was to evaluate azygos blood flow measurements by endoscopic ultrasound. METHODS: Measurements of azygos blood flow by EUS and by the thermodilution...... technique were compared in 20 patients with portal hypertension. The ability of EUS flowmetry to detect changes in the azygos and portal venous flow after an intravenous dose of 2 mg of terlipressin was evaluated in 13 of the patients in a double-blind, randomized, placebo-controlled, cross-over design....... RESULTS: The EUS Doppler and thermodilution measurements correlated significantly (R=0.81, P blood flow was found to be 14% higher by the EUS method than by thermodilution. The coefficient of variation of the EUS Doppler measurements of the azygos blood flow was 14.8%. After...

  2. New photoelectric method for inside cylindricity measurement

    Science.gov (United States)

    Yu, Houyun; Zhao, Zhuanping; Zhao, Ye; Xu, Meijian

    2007-12-01

    Cylindricity is an important parameter in the evaluation for a cylindraceous workpiece. It has a direct effect on the precision of assembly and rotation. However it is difficult to carry out inside cylindricity measurement for a large workpiece (length: 2~3m, diameter >200mm), in which the spindle's straightness and measuring table's motion error deserve consideration. In this paper, a new error separation method is presented based on the application of precise photoelectric inspecting technique. And the two errors will be directly measured according to the deviation of facula. During the measurement, the workpiece is installed erectly on the base to minimize its distortion. Laser collimation initializes the measuring needle and gives real-time state of the measuring table. Two kinds of coordinates are used for error compensation, i.e. absolute and imaging coordinates. In the end, the least squares cylinder is used to calculate the cylindricity after all point data of each section are modified. Overall structure design and detailed measuring steps are also listed. Thus, the models of error compensation and cylindricity evaluation are obtained. Simulation results prove them correct with a satisfying precision.

  3. Phenomenon of declining blood pressure in elderly - high systolic levels are undervalued with Korotkoff method

    Directory of Open Access Journals (Sweden)

    Elmståhl Sölve

    2011-10-01

    Full Text Available Abstract Background Systolic blood pressure (SBP decline has been reported in octogenarians. The aim was to study if it could be observed while measuring SBP with two methods: Korotkoff (K-BP and Strain-Gauge-Finger-Pletysmography (SG-BP, and which of them were more reliable in expressing vascular burden. Methods A cohort of 703 men from a population of Malmö, Sweden, were included in "Men born in 1914-study" and followed-up at ages: 68 and 81 years. 176 survivors were examined with K-BP and SG-BP at both ages, and 104 of them with Ambulatory Blood Pressure at age 81/82. Ankle Brachial Index (ABI was measured on both occasions, and Carotid Ultrasound at age 81. Results From age 68 to 81, mean K-BP decreased in the cohort with mean 8.3 mmHg, while SG-BP increased with 13.4 mmHg. K-BP decreased in 55% and SG-BP in 31% of the subjects. At age 81, K-BP was lower than SG-BP in 72% of subjects, and correlated to high K-BP at age 68 (r = --.22; p Conclusion In contrast to K-BP, values of SG-BP in octogenarians strongly correlated with Ambulatory Blood Pressure. The SG-BP decline in the last decade was rare, and increasing SG-BP better than K-BP reflected advanced atherosclerosis. It should be aware, that K-BP underdetected 46% of subjects with SG-BP equal/higher than 140 mmHg at age 81, which may lead to biased associations with risk factors due to differential misclassification by age.

  4. Electric Field Quantitative Measurement System and Method

    Science.gov (United States)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  5. [Subjective verbal methods in preoperative measurement of anxiety].

    Science.gov (United States)

    Höfling, S; Hutner, G; Ott, H; Fichte, K; Doenicke, A

    1988-06-01

    The role of preoperative anxiety in perioperative adaptation is viewed in two different ways. Janis suggested that anxiety is a drive that evokes the cognitive work of worrying. Leventhal stresses the importance of coping behavior for adaptation, while anxiety may or may not accompany this coping process. Both theories have empirical support. The aim of this study was to determine whether both theories could show empirical support because the scientists chose different methods: Janis used interviews, Leventhal and Lazarus anxiety scales. The study analyzed the pre- and postoperative emotional reactions of surgical patients with three different methods of anxiety measurement: an anxiety scale, a fear thermometer, and a psychoanalytic interview (Gottschalk-Gleser content analysis method). The different methods were compared and related to the adaptation behavior (Table 3). The data showed a clear interaction between the selected methods and respective theories about the effects of preoperative anxiety on intra- and postoperative adaptation. The anxiety scales showed no correlation with adaptation behavior (blood pressure and heart rate during surgery; postoperative pain medication) and were not related to the anxiety scores obtained from the interview (content analysis). On the other hand, the interview anxiety measurements showed a clear relationship between separation anxiety (and also shame anxiety), physiological excitement during surgery (increase in heart rate), and postoperative medication (increased analgesics and tranquilizers). The patients who worried about the risks of surgery (Verletzungsangst, see Fig. 3) had very good perioperative adjustment, so that the quality of anxiety measured in the interview was very important for the prediction of adaptation.

  6. A decision support system for quantitative measurement of operational efficiency in a blood collection facility.

    Science.gov (United States)

    Kros, John F; Yim Pang, Robyn

    2004-04-01

    A decision support system (DSS) is presented that allows users to input, analyze, and output data derived from blood banking operations. The DSS developed is a hybrid system that is both data and model driven. The system provides information, models, and data manipulation tools to assist users in the quantitative measurement of the operational efficiency in a blood collection facility. A relational database was developed to address the four major variables, which impact the cost per unit of blood being collected. Using visual basic, a user interface and mathematical model were developed establishing the relationships to analyze cost per unit of collected blood. Using inputs from users and historical financial data, the DSS calculates the cost per unit as each of the major variables is altered. Real life situations by the mobile operations team at a blood collection facility were used to test the DSS.

  7. 石墨炉原子吸收法测定全血标本铅含量的3种前处理方法%Comparison of three specimen pretreatment methods for measuring lead content in whole blood by graphite furnace a-tomic absorption spectrometry

    Institute of Scientific and Technical Information of China (English)

    张斯恩; 张贝基; 谭红丽

    2014-01-01

    比较石墨炉原子吸收法测定全血标本中铅的3种前处理方法优劣,从中筛选一种更简便、准确、灵敏的方法,从而达到提高检测质量,降低工作强度的目的。方法采用酸脱蛋白法、混合基体改进剂法、微波消解法对无铅接触史的健康成年人全血标本进行前处理,分别用石墨炉原子吸收法检测,对检测结果进行统计分析,比较标准曲线线性、相关系数(r)、相对标准偏差(RSD%)、准确度等指标。结果3种方法标准曲线 r分别为0.9965、0.9942、0.9995;检出限分别为5.4、3.6、2.7μg/L ;RSD%分别为4.1、4.5、2.8;回收率分别为95.7%~103.3%、98.7%~104.5%、98.3%~102.3%。结论微波消解处理全血标本各项指标均令人满意,是测量血铅较好的前处理方法。%Objective To compare three specimen pretreatment methods for measuring lead content in whole blood by graphite furnace atomic absorption spectrometry .Methods Whole blood of healthy adults without lead ex‐posure history were pretreated by using acid deproteinized method ,mixed matrix modifier method ,and microwave di‐gestion method ,and then detected for lead content by using graphite furnace atomic absorption spectrometry .All re‐sults were statistically analyzed to compare indicators ,including standard curve′s linear ,correlation coefficient ,rela‐tive standard deviation (RSD% ) ,accuracy and so on .Results Correlation coefficients of standard curve of the three methods were 0 .996 5 ,0 .994 2 and 0 .999 5 ,the minimum detectable concentration were 5 .4 ,3 .6 and 2 .7 μg/L , RSD% were 4 .1 ,4 .5 and 2 .8 ,and the recovery rates were 95 .7% -103 .3% ,98 .7% -104 .5% and 98 .3% -102 .3% .Conclusion The evaluation indicators of microwave digestion method could be satisfactory ,which might be an ideal method for pretreatment of blood specimens for detection of lead content .

  8. A centenary of auscultatory blood pressure measurement: a tribute to Nikolai Korotkoff.

    Science.gov (United States)

    Paskalev, Dobrin; Kircheva, Anna; Krivoshiev, Stefan

    2005-01-01

    In 1905, Dr. Nikolai Korotkoff (1874-1920), a Russian surgeon, discovered a simple and precise technique to measure arterial pressure. He was born on 26th February 1874 in the central Russian city of Kursk. Korotkoff graduated from the Medical Faculty of Moscow University in 1898, but he worked later in the Surgical Clinic at the Imperial Military Medical Academy in St. Petersburg (Russia). Korotkoff served as a military surgeon during the Russo-Japanese War (1904-1905) and his major efforts were to find reliable clinical signs that could predict whether limb flow would be viable after vascular surgery of traumatic aneurysm. He found that after complete compression, the aneurysm of the arm (i.e. distal pulse on a. brachialis) disappeared with Riva-Rocci cuff and then gradually decreasing the pressure, a series of sounds could be heard by stethoscope under the artery distal to the compression. Korotkoff described four distinct phases of sounds: first sound, then compression murmurs, second tone, and disappearance of sounds. Korotkoff was also able to demonstrate the same auscultatory finding in healthy persons. He failed to notice only the muffled second sound, which was demonstrated a little later. These classical observations are now well known as the five different phases of Korotkoff sounds. In November 1905, during a conference of the Imperial Military Medical Academy, he reported his discovery in a short presentation entitled 'On the issue of the methods for measuring blood pressure'. In 1939, the Joint Committee of the American Heart Association and the Cardiac Society of Great Britain and Ireland recognized officially and accepted worldwide Korotkoff's method for blood pressure determining.

  9. Perfusion MRI (dynamic susceptibility contrast imaging) with different measurement approaches for the evaluation of blood flow and blood volume in human gliomas

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, H. (Den Sundhedsfaglige Kandidatuddannelse, Aarhus Universitet Bygning 1264, Aarhus (Denmark); University College Nordjylland, Aalborg (Denmark)), Email: hnt@ucn.dk; Steffensen, E. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark)); Larsson, E. M. (Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden))

    2012-02-15

    Background. Perfusion magnetic resonance imaging (MRI) is increasingly used in the evaluation of brain tumors. Relative cerebral blood volume (rCBV) is usually obtained by dynamic susceptibility contrast (DSC) MRI using normal appearing white matter as reference region. The emerging perfusion technique arterial spin labelling (ASL) presently provides measurement only of cerebral blood flow (CBF), which has not been widely used in human brain tumor studies. Purpose. To assess if measurement of blood flow is comparable with measurement of blood volume in human biopsy-proven gliomas obtained by DSC-MRI using two different regions for normalization and two different measurement approaches. Material and Methods. Retrospective study of 61 patients with different types of gliomas examined with DSC perfusion MRI. Regions of interest (ROIs) were placed in tumor portions with maximum perfusion on rCBF and rCBV maps, with contralateral normal appearing white matter and cerebellum as reference regions. Larger ROIs were drawn for histogram analyses. The type and grade of the gliomas were obtained by histopathology. Statistical comparison was made between diffuse astrocytomas, anaplastic astrocytomas, and glioblastomas. Results. rCBF and rCBV measurements obtained with the maximum perfusion method were correlated when normalized to white matter (r = 0.60) and to the cerebellum (r = 0.49). Histogram analyses of rCBF and rCBV showed that mean and median values as well as skewness and peak position were correlated (0.61 < r < 0.93), whereas for kurtosis and peak height, the correlation coefficient was about 0.3 when comparing rCBF and rCBV values for the same reference region. Neither rCBF nor rCBV quantification provided a statistically significant difference between the three types of gliomas. However, both rCBF and rCBV tended to increase with tumor grade and to be lower in patients who had undergone resection/treatment. Conclusion. rCBF measurements normalized to white matter

  10. Optical methods for correction of oxygen-transport characteristics of blood and their biomedical applications

    Science.gov (United States)

    Zalesskaya, G. A.; Akulich, N. V.; Marochkov, A. V.; Laskina, O. V.; Mit'kovskaya, N. P.

    2010-07-01

    We have carried out a comprehensive analysis of the spectral characteristics of blood and blood components, gas-exchange and oximetry parameters for venous and arterial blood, central hemodynamic parameters, and the results of a complete blood count and chemistry panel before and after extracorporeal UV irradiation of the blood (UBI, ultraviolet blood irradiation) or intravenous exposure of blood to low-intensity emission from an He-Ne laser (LBI, laser blood irradiation). We have demonstrated the possibility of correcting the oxygentransport characteristics of blood by laser optical methods based on photodissociation of blood oxyhemoglobin. We have shown that the therapeutic effects initiated both by UBI and LBI are based on a single mechanism: a change in the balance between production of active oxygen species and their inhibition by antioxidants. The data obtained are of interest not only for studying the primary (molecular) mechanisms of action for photohemotherapy and their effect on processes occurring in the living body, but also can provide a basis for designing next-generation laser optical instruments and for development of not yet existing methods for assessing the therapeutic efficacy of photohemotherapy.

  11. Measurement of cerebral blood flow rate and its relationship with brain function using optical coherence tomography

    Science.gov (United States)

    Liu, Jian; Wang, Yi; Zhao, Yuqian; Dou, Shidan; Ma, Yushu; Ma, Zhenhe

    2016-03-01

    Activity of brain neurons will lead to changes in local blood flow rate (BFR). Thus, it is important to measure the local BFR of cerebral cortex on research of neuron activity in vivo, such as rehabilitation evaluation after stroke, etc. Currently, laser Doppler flowmetry is commonly used for blood flow measurement, however, relatively low resolution limits its application. Optical coherence tomography (OCT) is a powerful noninvasive 3D imaging modality with high temporal and spatial resolutions. Furthermore, OCT can provide flow distribution image by calculating Doppler frequency shift which makes it possible for blood flow rate measurement. In this paper, we applied OCT to measure the blood flow rate of the primary motor cortex in rats. The animal was immobilized and anesthetized with isoflurane, an incision was made along the sagittal suture, and bone was exposed. A skull window was opened on the primary motor cortex. Then, blood flow rate changes in the primary motor cortex were monitored by our homemade spectral domain OCT with a stimulation of the passive movement of the front legs. Finally, we established the relationship between blood flow rate and the test design. The aim is to demonstrate the potential of OCT in the evaluation of cerebral cortex function.

  12. [Physical activity level and home blood pressure measurement: Pilot study "Acti-HTA"].

    Science.gov (United States)

    Sosner, P; Ott, J; Steichen, O; Bally, S; Krummel, T; Brucker, M; Lequeux, B; Dourmap, C; Llaty, P; Le Coz, S; Baguet, S; Miranne, A; Labrunée, M; Gremeaux, V; Lopez-Sublet, M

    2015-06-01

    While physical activity (PA) is recommended for high blood pressure management, the level of PA practice of hypertensive patients remains unclear. We aimed to assess the association between the level of both PA and blood pressure of individuals consulting in 9 hypertension specialist centres. Eighty-five hypertensive patients were included (59 ± 14 years, 61% men, 12% smokers, 29% with diabetes). Following their consultation, they performed home blood pressure measurement (HBPM) over 7 days (2 in the morning+2 in the evening), they wrote in a dedicated form their daily activities to estimate the additional caloric expenditure using Acti-MET device (built from International physical Activity Questionnaire [IPAQ]). Thus, patients completed a self-administered questionnaire "score of Dijon" (distinguishing active subjects with a score>20/30, from sedentary<10/30). Subjects with normal HBPM value (<135/85 mm Hg) (55% of them) compared to those with high HBPM were older, had a non-significant trend towards higher weekly caloric expenditure (4959 ± 5045 kcal/week vs. 4048 ± 4199 kcal/week, P=0.3755) and score of Dijon (19.44 ± 5.81 vs. 18.00 ± 4.32, P=0.2094) with a higher proportion of "active" subjects (48.9% vs. 34.2%, P=0.1773). In conclusion, our results demonstrate a "tendency" to a higher level of reported PA for subjects whose hypertension was controlled. This encourages us to continue with a study that would include more subjects, which would assess PA level using an objective method such as wearing an accelerometer sensor.

  13. Flow measurements in a blood-perfused collagen vessel using x-ray micro-particle image velocimetry.

    Science.gov (United States)

    Antoine, Elizabeth; Buchanan, Cara; Fezzaa, Kamel; Lee, Wah-Keat; Rylander, M Nichole; Vlachos, Pavlos

    2013-01-01

    Blood-perfused tissue models are joining the emerging field of tumor engineering because they provide new avenues for modulation of the tumor microenvironment and preclinical evaluation of the therapeutic potential of new treatments. The characterization of fluid flow parameters in such in-vitro perfused tissue models is a critical step towards better understanding and manipulating the tumor microenvironment. However, traditional optical flow measurement methods are inapplicable because of the opacity of blood and the thickness of the tissue sample. In order to overcome the limitations of optical method we demonstrate the feasibility of using phase-contrast x-ray imaging to perform microscale particle image velocimetry (PIV) measurements of flow in blood perfused hydrated tissue-representative microvessels. However, phase contrast x-ray images significantly depart from the traditional PIV image paradigm, as they have high intensity background, very low signal-to-noise ratio, and volume integration effects. Hence, in order to achieve accurate measurements special attention must be paid to the image processing and PIV cross-correlation methodologies. Therefore we develop and demonstrate a methodology that incorporates image preprocessing as well as advanced PIV cross-correlation methods to result in measured velocities within experimental uncertainty.

  14. Flow measurements in a blood-perfused collagen vessel using x-ray micro-particle image velocimetry.

    Directory of Open Access Journals (Sweden)

    Elizabeth Antoine

    Full Text Available Blood-perfused tissue models are joining the emerging field of tumor engineering because they provide new avenues for modulation of the tumor microenvironment and preclinical evaluation of the therapeutic potential of new treatments. The characterization of fluid flow parameters in such in-vitro perfused tissue models is a critical step towards better understanding and manipulating the tumor microenvironment. However, traditional optical flow measurement methods are inapplicable because of the opacity of blood and the thickness of the tissue sample. In order to overcome the limitations of optical method we demonstrate the feasibility of using phase-contrast x-ray imaging to perform microscale particle image velocimetry (PIV measurements of flow in blood perfused hydrated tissue-representative microvessels. However, phase contrast x-ray images significantly depart from the traditional PIV image paradigm, as they have high intensity background, very low signal-to-noise ratio, and volume integration effects. Hence, in order to achieve accurate measurements special attention must be paid to the image processing and PIV cross-correlation methodologies. Therefore we develop and demonstrate a methodology that incorporates image preprocessing as well as advanced PIV cross-correlation methods to result in measured velocities within experimental uncertainty.

  15. Invasive and non-invasive methods for cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Lavdaniti M.

    2008-01-01

    Full Text Available The hemodynamic status monitoring of high-risk surgical patients and critically ill patients inIntensive Care Units is one of the main objectives of their therapeutic management. Cardiac output is one of the mostimportant parameters for cardiac function monitoring, providing an estimate of whole body perfusion oxygen deliveryand allowing for an understanding of the causes of high blood pressure. The purpose of the present review is thedescription of cardiac output measurement methods as presented in the international literature. The articles documentthat there are many methods of monitoring the hemodynamic status of patients, both invasive and non-invasive, themost popular of which is thermodilution. The invasive methods are the Fick method and thermodilution, whereasthe non-invasive methods are oeshophaegeal Doppler, transoesophageal echocardiography, lithium dilution, pulsecontour, partial CO2 rebreathing and thoracic electrical bioimpedance. All of them have their advantages and disadvantages,but thermodilution is the golden standard for critical patients, although it does entail many risks. The idealsystem for cardiac output monitoring would be non-invasive, easy to use, reliable and compatible in patients. A numberof research studies have been carried out in clinical care settings, by nurses as well as other health professionals, for thepurpose of finding a method of measurement that would have the least disadvantages. Nevertheless, the thermodilutiontechnique remains the most common approach in use today.

  16. Ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography with cryogenic oven trapping.

    Science.gov (United States)

    Watanabe-Suzuki, K; Seno, H; Ishii, A; Kumazawa, T; Suzuki, O

    1999-04-30

    We have established an ultra-sensitive method for determination of ethanol in whole blood by headspace capillary gas chromatography (GC) with cryogenic oven trapping. After heating a blood sample containing ethanol and isobutyl alcohol (internal standard, IS) in a 7.0-ml vial at 55 degrees C for 15 min, 5 ml of the headspace vapor was drawn into a glass syringe and injected into a GC port. All vapor was introduced into an Rtx-BAC2 wide-bore capillary column in the splitless mode at -60 degrees C oven temperature to trap entire analytes, and then the oven temperature was programmed up to 240 degrees C for GC measurements with flame ionization detection. The present method gave sharp peaks of ethanol and IS, and low background noise for whole blood samples. The mean partition into the gaseous phase for ethanol and IS was 3.06+/-0.733 and 8.33+/-2.19%, respectively. The calibration curves showed linearity in the range 0.02-5.0 microg/ml whole blood. The detection limit was estimated to be 0.01 microg/ml. The coefficients of intra-day and inter-day variation for spiked ethanol were 8.72 and 9.47%, respectively. Because of the extremely high sensitivity, we could measure low levels of endogenous ethanol in whole blood of subjects without drinking. The concentration of endogenous ethanol measured for 10 subjects under uncontrolled conditions varied from 0 to 0.377 microg/ml (mean, 0.180 microg/ml). Data on the diurnal changes of endogenous ethanol in whole blood of five subjects under strict food control are also presented; they are in accordance with the idea that endogenous blood ethanol is of enteric bacterial origin.

  17. Blood Contamination in Saliva: Impact on the Measurement of Salivary Oxidative Stress Markers.

    Science.gov (United States)

    Kamodyová, Natália; Baňasová, Lenka; Janšáková, Katarína; Koborová, Ivana; Tóthová, Ľubomíra; Stanko, Peter; Celec, Peter

    2015-01-01

    Salivary oxidative stress markers represent a promising tool for monitoring of oral diseases. Saliva can often be contaminated by blood, especially in patients with periodontitis. The aim of our study was to examine the impact of blood contamination on the measurement of salivary oxidative stress markers. Saliva samples were collected from 10 healthy volunteers and were artificially contaminated with blood (final concentration 0.001-10%). Next, saliva was collected from 12 gingivitis and 10 control patients before and after dental hygiene treatment. Markers of oxidative stress were measured in all collected saliva samples. Advanced oxidation protein products (AOPP), advanced glycation end products (AGEs), and antioxidant status were changed in 1% blood-contaminated saliva. Salivary AOPP were increased in control and patients after dental treatment (by 45.7% and 34.1%, p Saliva samples with 1% blood contamination are visibly discolored and can be excluded from analyses without any specific biochemic detection of blood constituents. Salivary markers of oxidative stress were significantly altered in blood-contaminated saliva in control and patients with gingivitis after dental hygiene treatment.

  18. Prognostic significance of distal blood pressure measurements in patients with severe ischaemia

    DEFF Research Database (Denmark)

    Paaske, William; Tønnesen, K H

    1980-01-01

    The clinical course was followed and the ankle and toe blood pressures were measured with the strain gauge technique on 5 occasions during 2 years in 43 patients with pain at rest and/or ischaemic ulceration due to severe ischaemia of the legs on the basis of occlusive arterial disease. Although...... arteriosclerosis of the legs in non-diabetic patients is generally considered a benign disease from the standpoint of limb survival, the critical level of TPI (systolic toe blood pressure/systolic arm blood pressure) was found to be 0.07 as a TPI below this value was associated with an overall 82% risk...

  19. Measurement of Blood Coagulation Factor Synthesis in Cultures of Human Hepatocytes.

    Science.gov (United States)

    Heinz, Stefan; Braspenning, Joris

    2015-01-01

    An important function of the liver is the synthesis and secretion of blood coagulation factors. Within the liver, hepatocytes are involved in the synthesis of most blood coagulation factors, such as fibrinogen, prothrombin, factor V, VII, IX, X, XI, XII, as well as protein C and S, and antithrombin, whereas liver sinusoidal endothelial cells produce factor VIII and von Willebrand factor. Here, we describe methods for the detection and quantification of most blood coagulation factors in hepatocytes in vitro. Hepatocyte cultures indeed provide a valuable tool to study blood coagulation factors. In addition, the generation and expansion of hepatocytes or hepatocyte-like cells may be used in future for cell-based therapies of liver diseases, including blood coagulation factor deficiencies.

  20. In vivo μPIV measurements of blood velocity in small vessels of a rat model

    Science.gov (United States)

    Leong, Chia Min; Russell, John; Connor, Nadine; Honkanen, Markus; Wei, Timothy

    2009-11-01

    Aging-related muscular changes have been shown to affect voice production. There is correlation between muscular changes and changes in capillary hemodynamics and structure with aging. Alterations in oxygen transport to cells and tissues at the capillary level has been hypothesized as one of the key factors that causes muscular changes thus voice production. Since oxygen transport is related to hemodynamics, we start by measuring blood velocity in capillaries of cremaster muscle of a living rat. The μPIV technique is adapted for measuring blood velocity where red blood cells are used as `seeding particles'. The accuracy of the μPIV measurements are determined by comparison with results obtained using other techniques such as particle tracking velocimetry (PTV). Finally, challenges in measuring flow through three-dimensional larynx geometry will be discussed.

  1. Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections.

    Directory of Open Access Journals (Sweden)

    Anne J M Loonen

    Full Text Available For patients suffering from bloodstream infections (BSI molecular diagnostics from whole blood holds promise to provide fast and adequate treatment. However, this approach is hampered by the need of large blood volumes. Three methods for pathogen DNA isolation from whole blood were compared, i.e. an enzymatic method (MolYsis, 1-5 ml, the novel non-enzymatic procedure (Polaris, 1-5 ml, and a method that does not entail removal of human DNA (Triton-Tris-EDTA EasyMAG, 200 µl. These methods were evaluated by processing blood spiked with 0-1000 CFU/ml of Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans. Downstream detection was performed with real-time PCR assays. Polaris and MolYsis processing followed by real-time PCRs enabled pathogen detection at clinically relevant concentrations of 1-10 CFU/ml blood. By increasing sample volumes, concurrent lower cycle threshold (Ct values were obtained at clinically relevant pathogen concentrations, demonstrating the benefit of using larger blood volumes. A 100% detection rate at a concentration of 10 CFU/ml for all tested pathogens was obtained with the Polaris enrichment, whereas comparatively lower detection rates were measured for MolYsis (50-67% and EasyMAG (58-79%. For the samples with a concentration of 1 CFU/ml Polaris resulted in most optimal detection rates of 70-75% (MolYsis 17-50% and TTE-EasyMAG 20-36%. The Polaris method was more reproducible, less labour intensive, and faster (45 minutes (including Qiagen DNA extraction vs. 2 hours (MolYsis. In conclusion, Polaris and MolYsis enrichment followed by DNA isolation and real-time PCR enables reliable and sensitive detection of bacteria and fungi from 5 ml blood. With Polaris results are available within 3 hours, showing potential for improved BSI diagnostics.

  2. TNO finger pressure reference guide: guide for the non-invasive finger blood pressure measurement and recording systems Portapres and Finometer

    NARCIS (Netherlands)

    2001-01-01

    With Portapres and Finometer continuous beat-to-beat finger blood pressure is measured. Although it is relatively easy to perform measurements, a basic understanding of the principles of the device is recommended to obtain reliable measurements. This reference guide addresses the volume-clamp method

  3. Modified methods of stellar magnetic field measurements

    CERN Document Server

    Kholtygin, A F

    2013-01-01

    The standard methods of the magnetic field measurement, based on an analysis of the relation between the Stokes $V$-parameter and the first derivative of the total line profile intensity, were modified by applying a linear integral operator $\\hat{L}$ to the both sides of this relation. As the operator $\\hat{L}$, the operator of the wavelet transform with DOG-wavelets is used. The key advantage of the proposed method is an effective suppression of the noise contribution to the line profile and the Stokes parameter $V$. The efficiency of the method has been studied using the model line profiles with various noise contributions. To test the proposed method, the spectropolarimetric observations of the A0-type star $\\alpha^2\\,$ CVn, young O-type star $\\theta^1$ Ori C and A0 supergiant HD 92207 were used. The longitudinal magnetic field strengths for these stars calculated by our method appeared to be in a good agreement with those determined by other methods.

  4. Continuous measurement of cerebral cortical blood flow by laser-Doppler flowmetry in a rat stroke model

    Energy Technology Data Exchange (ETDEWEB)

    Dirnagl, U.; Kaplan, B.; Jacewicz, M.; Pulsinelli, W. (Cornell Univ. Medical College, New York, NY (USA))

    1989-10-01

    Laser-Doppler flowmetry (LDF), a new method allowing instantaneous, continuous, and noninvasive measurements of microcirculatory blood flow in a small tissue sample, was evaluated for its accuracy in monitoring regional cerebral blood flow (rCBF) in the cortical microcirculation after focal cerebral ischemia. Wistar and spontaneously hypertensive rats (SHR, n = 19) were subjected to permanent occlusion of the middle cerebral and common carotid arteries. Absolute rCBF in a tissue sample of the ischemic hemisphere was measured autoradiographically with ({sup 14}C)iodoantipyrine as a tracer and compared to rCBF measured by LDF. Additionally, the percent change in rCBF between baseline and ischemic values was compared for both methods. Absolute rCBF values recorded with LDF correlated poorly (r = 0.54) with ({sup 14}C)iodoantipyrine measurements. In contrast LDF readings expressed as a percentage of ischemic vs. preocclusion readings (relative LDF readings) correlated very well (r = 0.91) with the percent change in (14C)iodoantipyrine measurements. We conclude that LDF does not provide accurate measurements of absolute rCBF values but this method allows accurate measurements of changes in rCBF due to induction of focal cerebral ischemia.

  5. Continuous measurement of cerebral cortical blood flow by laser-Doppler flowmetry in a rat stroke model.

    Science.gov (United States)

    Dirnagl, U; Kaplan, B; Jacewicz, M; Pulsinelli, W

    1989-10-01

    Laser-Doppler flowmetry (LDF), a new method allowing instantaneous, continuous, and noninvasive measurements of microcirculatory blood flow in a small tissue sample, was evaluated for its accuracy in monitoring regional cerebral blood flow (rCBF) in the cortical microcirculation after focal cerebral ischemia. Wistar and spontaneously hypertensive rats (SHR, n = 19) were subjected to permanent occlusion of the middle cerebral and common carotid arteries. Absolute rCBF in a tissue sample of the ischemic hemisphere was measured autoradiographically with [14C]iodoantipyrine as a tracer and compared to rCBF measured by LDF. Additionally, the percent change in rCBF between baseline and ischemic values was compared for both methods. Absolute rCBF values recorded with LDF correlated poorly (r = 0.54) with [14C]iodoantipyrine measurements. In contrast LDF readings expressed as a percentage of ischemic vs. preocclusion readings (relative LDF readings) correlated very well (r = 0.91) with the percent change in [14C]iodoantipyrine measurements. We conclude that LDF does not provide accurate measurements of absolute rCBF values but this method allows accurate measurements of changes in rCBF due to induction of focal cerebral ischemia.

  6. LASER-DOPPLER BLOOD FLOWMETRY USING 2 WAVELENGTHS - MONTE-CARLO SIMULATIONS AND MEASUREMENTS

    NARCIS (Netherlands)

    KOELINK, MH; DEMUL, FFM; GREVE, J; GRAAFF, R; DASSEL, ACM; AARNOUDSE, JG

    1994-01-01

    A new laser Doppler blood flowmeter for measuring skin perfusion is presented. The flowmeter consists of a probe that uses two different wavelengths and is able to measure at different depths. It may be used to distinguish the superficial microcirculation of the skin providing nutritional flow and t

  7. The measurement of digital systolic blood pressure by strain gauge technique

    DEFF Research Database (Denmark)

    Nielsen, P E; Bell, G; Lassen, N A

    1972-01-01

    The systolic blood pressure on the finger, toe, and ankle has been measured by a strain gauge technique in 10 normal subjects aged 17-31 years and 14 normal subjects aged 43-57 years. The standard deviation in repeated measurements lies between 2 and 6 mm Hg. The finger pressure in the younger...

  8. A method for calculating regional cerebral blood flow from emission computed tomography of inert gas concentrations

    DEFF Research Database (Denmark)

    Celsis, P; Goldman, T; Henriksen, L;

    1981-01-01

    of four 1 min pictures and using a fixed value for the brain:blood partition coefficient, lambda. The method is essentially based on the bolus distribution principle, and it allows the estimation of blood flow in ischemic areas. Application to positron emission tomography is discussed....

  9. Cost estimation of hypertension management based on home blood pressure monitoring alone or combined office and ambulatory blood pressure measurements.

    Science.gov (United States)

    Boubouchairopoulou, Nadia; Karpettas, Nikos; Athanasakis, Kostas; Kollias, Anastasios; Protogerou, Athanase D; Achimastos, Apostolos; Stergiou, George S

    2014-10-01

    This study aims at estimating the resources consumed and subsequent costs for hypertension management, using home blood pressure (BP) monitoring (HBPM) alone versus combined clinic measurements and ambulatory blood pressure monitoring (C/ABPM). One hundred sixteen untreated hypertensive subjects were randomized to use HBPM or C/ABPM for antihypertensive treatment initiation and titration. Health resources utilized within 12-months follow-up, their respective costs, and hypertension control were assessed. The total cost of the first year of hypertension management was lower in HBPM than C/ABPM arm (€1336.0 vs. €1473.5 per subject, respectively; P cost was identical in both arms. There was no difference in achieved BP control and drug expenditure (HBPM: €233.1 per subject; C/ABPM: €247.6 per subject; P = not significant), whereas the cost of BP measurements and/or visits was higher in C/ABPM arm (€393.9 vs. €516.9, per patient, respectively P cost for subsequent years (>1) was €348.9 and €440.2 per subject, respectively for HBPM and C/ABPM arm and €2731.4 versus €3234.3 per subject, respectively (P cost than C/ABPM, and the same trend is observed in 5-year projection. The results on the resources consumption can be used to make cost estimates for other health-care systems.

  10. Evaluation of dried blood spots with a multiplex assay for measuring recent HIV-1 infection.

    Directory of Open Access Journals (Sweden)

    Kelly A Curtis

    Full Text Available Laboratory-based HIV tests for recent infection (TRIs, which primarily measure a specific serological biomarker(s that distinguishes recent from long-term HIV infection, have facilitated the estimation of population-based incidence. Dried blood spots (DBS on filter paper are an attractive sample source for HIV surveillance, given the simplified and cost-effective methods of specimen collection, storage, and shipment. Here, we evaluated the use of DBS in conjunction with an in-house multiplex TRI, the HIV-1-specific Bio-Plex assay, which measures direct antibody binding and avidity to multiple HIV-1 analytes. The assay performance was comparable between matched plasma and DBS samples from HIV-1 infected individuals obtained from diverse sources. The coefficients of variation, comparing the median antibody reactivity for each analyte between plasma and DBS, ranged from 2.78% to 9.40% and the correlation coefficients between the two sample types ranged from 0.89 to 0.97, depending on the analyte. The correlation in antibody reactivity between laboratory and site-prepared DBS for each analyte ranged from 0.87 to 0.98 and from 0.90 to 0.97 between site-prepared DBS and plasma. The correlation in assay measures between plasma and DBS indicate that the sample types can be used interchangeably with the Bio-Plex format, without negatively impacting the misclassification rate of the assay.

  11. Validation of a blood group genotyping method based on high-resolution melting curve analysis.

    Science.gov (United States)

    Gong, Tianxiang; Hong, Ying; Wang, Naihong; Fu, Xuemei; Zhou, Changhua

    2014-01-01

    The detection of polymorphism is the basis of blood group genotyping and phenotype prediction. Genotyping may be useful to determine blood groups when serologic results are unclear. The development and application of different methods for blood group genotyping may be needed as a substitute for blood group typing. The purpose of this study is to establish an approach for blood group genotyping based on a melting curve analysis of real-time polymerase chain reaction (PCR). Using DNA extracted from whole blood, we developed and validated a DNA typing method for detecting DO*01/DO*02, DO*01/DI*02, LU*01/LU*02, and GYPB*03/GYBP*04 alleles using a melting curve analysis. All assays were confirmed with a commercial reagent containing sequence-specific primers (PCR-SSP), and a cohort of the samples was confirmed with sequencing. Results for all blood groups were within the range of specificity and assay variability. Genotypes of 300 blood donors were fully consistent with PCR-SSP data. The obtained genotype distribution is in complete concordance with existing data for the Chinese population. There are several advantages for this approach of blood group genotyping: lower contamination rates with PCR products in this laboratory, ease of performance, automation potential, and rapid cycling time.

  12. 血站非检测不合格血液报废的原因与预防措施%Causes and preventive measures ofdetecting unqualified blood scrapped blood non

    Institute of Scientific and Technical Information of China (English)

    尚卢清

    2015-01-01

    Objective: to analyze and evaluate the blood non detecting unqualified blood scrap reason, summing up the relevant preventive measures, in order to reduce the blood bank blood unqualiifed rate and disability rate.Method: select 2013 2014 I stand with the collected blood were 8000 bags and 9000 bags, reasons for detecting unqualiifed blood discarding statistical non, calculate the unqualiifed blood scrap rate.Results: a total of 5062 bags of blood due to the non detecting unqualiifed due to scrap its reasons, including insufifcient blood, blood fat, blood bag, color abnormal blood clots, etc..Conclusion: according to the blood bank blood discarding non unqualiifed phenomenon, blood bank should develop and implement feasible preventive measures, fundamentally reduce unnecessary blood scrap, so as to improve the utilization rate of blood, to ensure that our blood work smoothly.%目的:分析和探讨血站非检测不合格血液报废的原因,总结相关预防措施,以此降低血站所采血液不合格率与报废率。方法选取我站2013年与2014年所采集的血液分别24300袋与25600袋,统计非检测不合格血液报废的原因,计算出不合格血液报废率。结果共有3800袋血液由于非检测不合格导致报废,其原因包括采血量不足、脂肪血、采血袋破损、颜色异常、血凝块等。结论针对血站非检测不合格血液报废现象,血站应制定并实施切实可行的预防措施,从根本上降低不必要的血液报废,从而提高血液利用率,确保我国血站工作顺利进行。

  13. Self-measurement of blood pressure at home reduces the need for antihypertensive drugs - A randomized, controlled trial

    NARCIS (Netherlands)

    Verberk, Willem J.; Kroon, Abraham A.; Lenders, Jacques W. M.; Kessels, Alfons G. H.; van Montfrans, Gert A.; Smit, Andries J.; van der Kuy, Paul-Hugo M.; Nelemans, Patricia J.; Rennenberg, Roger J. M. W.; Grobbee, Diederick E.; Beltman, Frank W.; Joore, Manuela A.; Brunenberg, Danielle E. M.; Dirksen, Carmen; Thien, Theo; de Leeuw, Peter W.

    2007-01-01

    It is still uncertain whether one can safely base treatment decisions on self- measurement of blood pressure. In the present study, we investigated whether antihypertensive treatment based on self- measurement of blood pressure leads to the use of less medication without the loss of blood pressure c

  14. Calculation and verification of blood ethanol measurement uncertainty for headspace gas chromatography.

    Science.gov (United States)

    Sklerov, Jason H; Couper, Fiona J

    2011-09-01

    An estimate was made of the measurement uncertainty for blood ethanol testing by headspace gas chromatography. While uncertainty often focuses on compliance to a single threshold level (0.08 g/100 mL), the existence of multiple thresholds, related to enhanced sentencing, subject age, or commercial vehicle licensure, necessitate the use of an estimate with validity across multiple specification levels. The uncertainty sources, in order of decreasing magnitude, were method reproducibility, linear calibration, recovery, calibrator preparation, reference material, and sample preparation. A large set of reproducibility data was evaluated (n = 15,433) in order to encompass measurement variability across multiple conditions, operators, instruments, concentrations and timeframes. The relative, combined standard uncertainty was calculated as ±2.7%, with an expanded uncertainty of ±8.2% (99.7% level of confidence, k = 3). Bias was separately evaluated through a recovery study using standard reference material from a national metrology institute. The uncertainty estimate was verified through the use of proficiency test (PT) results. Assigned values for PT results and their associated uncertainties were calculated as robust means (x*) and standard deviations (s*) of participant values. Performance scores demonstrated that the uncertainty estimate was appropriate across the full range of PT concentrations (0.010-0.370 g/100 mL). The use of PT data as an empirical estimate of uncertainty was not examined. Until providers of blood ethanol PT samples include details on how an assigned value is obtained along with its uncertainty and traceability, the use of PT data should be restricted to the role of verification of uncertainty estimates.

  15. SMN Protein Can Be Reliably Measured in Whole Blood with an Electrochemiluminescence (ECL Immunoassay: Implications for Clinical Trials.

    Directory of Open Access Journals (Sweden)

    Phillip Zaworski

    Full Text Available Spinal muscular atrophy (SMA is caused by defects in the survival motor neuron 1 (SMN1 gene that encodes survival motor neuron (SMN protein. The majority of therapeutic approaches currently in clinical development for SMA aim to increase SMN protein expression and there is a need for sensitive methods able to quantify increases in SMN protein levels in accessible tissues. We have developed a sensitive electrochemiluminescence (ECL-based immunoassay for measuring SMN protein in whole blood with a minimum volume requirement of 5μL. The SMN-ECL immunoassay enables accurate measurement of SMN in whole blood and other tissues. Using the assay, we measured SMN protein in whole blood from SMA patients and healthy controls and found that SMN protein levels were associated with SMN2 copy number and were greater in SMA patients with 4 copies, relative to those with 2 and 3 copies. SMN protein levels did not vary significantly in healthy individuals over a four-week period and were not affected by circadian rhythms. Almost half of the SMN protein was found in platelets. We show that SMN protein levels in C/C-allele mice, which model a mild form of SMA, were high in neonatal stage, decreased in the first few weeks after birth, and then remained stable throughout the adult stage. Importantly, SMN protein levels in the CNS correlated with SMN levels measured in whole blood of the C/C-allele mice. These findings have implications for the measurement of SMN protein induction in whole blood in response to SMN-upregulating therapy.

  16. Comparing efficacy and safety of 2 methods of tranexamic acid administration in reducing blood loss following total knee arthroplasty

    Science.gov (United States)

    Fu, Yu; Shi, Zhigang; Han, Bing; Ye, Yong; You, Tao; Jing, Juehua; Li, Jun

    2016-01-01

    Abstract Background: The purpose of this systematic review and meta-analysis of randomized controlled trials (RCTs) were to gather data to evaluate the efficacy and safety of topical tranexamic acid (TXA) versus intravenous (IV) TXA for blood loss after a total knee arthroplasty (TKA). Methods: Electronic databases: Pubmed, Web of Science, Cochrane library, and Embase from inception to June 2016 were searched. RCTs that comparing topical with IV TXA for blood loss control in patients prepared for TKA were included in this meta-analysis. The Cochrane risk of bias tool was used to appraise risk of bias. The primary outcomes were needed for transfusion, total blood loss, and blood loss in drainage. Secondary outcomes are hemoglobin (Hb) value at 24-hour post TKA and complication (deep venous thrombosis [DVT] and infection). The efficacy of blood loss was tested by total blood loss, drainage volume, Hb drop, and the Hb value at 24 hours after TKA. The safety was measured by the occurrence of DVT and infection. Continuous outcomes were expressed as the mean difference with the respective 95% confidence intervals (CIs). Discontinuous outcomes were expressed as the relative risk with 95% CIs. Stata 12.0 software (Stata Corp., College Station, TX) was used for the meta-analysis. Results: A total of 14 articles involving 1390 patients were finally included for this meta-analysis. The pooled results revealed that there were no significant difference between the need for transfusion, total blood loss, blood loss in drainage, Hb value at 24-hour post TKA, the occurrence of complications (infection and DVT) between topical administration of TXA and IV TXA. Conclusion: Topical TXA has similar efficacy for blood loss control to IV TXA without sacrificing safety in TKA. However, the dose of topical TXA and IV TXA is different, thus, optimal timing and dose of TXA are still needed to explore the maximum effect of TXA. PMID:27977593

  17. Adaptive control with self-tuning for non-invasive beat-by-beat blood pressure measurement.

    Science.gov (United States)

    Nogawa, Masamichi; Ogawa, Mitsuhiro; Yamakoshi, Takehiro; Tanaka, Shinobu; Yamakoshi, Ken-ichi

    2011-01-01

    Up to now, we have successfully carried out the non-invasive beat-by-beat measurement of blood pressure (BP) in the root of finger, superficial temporal and radial artery based on the volume-compensation technique with reasonable accuracy. The present study concerns with improvement of control method for this beat-by-beat BP measurement. The measurement system mainly consists of a partial pressurization cuff with a pair of LED and photo-diode for the detection of arterial blood volume, and a digital self-tuning control method. Using healthy subjects, the performance and accuracy of this system were evaluated through comparison experiments with the system using a conventional empirically tuned PID controller. The significant differences of BP measured in finger artery were not showed in systolic (SBP), p=0.52, and diastolic BP (DBP), p=0.35. With the advantage of the adaptive control with self-tuning method, which can tune the control parameters without disturbing the control system, the application area of the non-invasive beat-by-beat measurement method will be broadened.

  18. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...... of healing correlated significantly with the three distal blood pressure parameters investigated, the closest correlation being with the SDBP measured at the final examination, i.e. just after healing of the ulcer or just before an inevitable major amputation. Of the 22 cases with SDBP below 20 mmHg only two...... (SPPH) as measured with a photocell. Thirty-two patients (35 feet with ulcerations) had diabetes mellitus. The treatment was conservative. In 42 feet the ulcers healed after an average period of 5.8 months; in 24 feet major amputation became necessary after an average of 4.3 months. The frequency...

  19. Gravimetric capillary method for kinematic viscosity measurements

    Science.gov (United States)

    Rosenberger, Franz; Iwan, J.; Alexander, D.; Jin, Wei-Qing

    1992-01-01

    A novel version of the capillary method for viscosity measurements of liquids is presented. Viscosity data can be deduced in a straightforward way from mass transfer data obtained by differential weighing during the gravity-induced flow of the liquid between two cylindrical chambers. Tests of this technique with water, carbon tetrachloride, and ethanol suggest that this arrangement provides an accuracy of about +/- 1 percent. The technique facilitates operation under sealed, isothermal conditions and, thus can readily be applied to reactive and/or high vapor pressure liquids.

  20. Low cost subpixel method for vibration measurement

    Science.gov (United States)

    Ferrer, Belen; Espinosa, Julian; Roig, Ana B.; Perez, Jorge; Acevedo, Pablo; Mas, David

    2014-05-01

    Traditional vibration measurement methods are based on devices that acquire local data by direct contact (accelerometers, GPS) or by laser beams (Doppler vibrometers). Our proposal uses video processing to obtain the vibration frequency directly from the scene, without the need of auxiliary targets or devices. Our video-vibrometer can obtain the vibration frequency at any point in the scene and can be implemented with low-cost devices, such as commercial cameras. Here we present the underlying theory and some experiments that support our technique.

  1. Low cost subpixel method for vibration measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ferrer, Belen [Department of Civil Engineering, Univ. Alicante P.O. Box, 99, 03080 Alicante (Spain); Espinosa, Julian; Perez, Jorge; Acevedo, Pablo; Mas, David [Inst. of Physics Applied to the Sciences and Technologies, Univ. Alicante P.O. Box, 99, 03080 Alicante (Spain); Roig, Ana B. [Department of Optics, Univ. Alicante P.O. Box, 99, 03080 Alicante (Spain)

    2014-05-27

    Traditional vibration measurement methods are based on devices that acquire local data by direct contact (accelerometers, GPS) or by laser beams (Doppler vibrometers). Our proposal uses video processing to obtain the vibration frequency directly from the scene, without the need of auxiliary targets or devices. Our video-vibrometer can obtain the vibration frequency at any point in the scene and can be implemented with low-cost devices, such as commercial cameras. Here we present the underlying theory and some experiments that support our technique.

  2. Measuring scholarly impact methods and practice

    CERN Document Server

    Rousseau, Ronald; Wolfram, Dietmar

    2014-01-01

    This book is an authoritative handbook of current topics, technologies and methodological approaches that may be used for the study of scholarly impact. The included methods cover a range of fields such as statistical sciences, scientific visualization, network analysis, text mining, and information retrieval. The techniques and tools enable researchers to investigate metric phenomena and to assess scholarly impact in new ways. Each chapter offers an introduction to the selected topic and outlines how the topic, technology or methodological approach may be applied to metrics-related research. Comprehensive and up-to-date, Measuring Scholarly Impact: Methods and Practice is designed for researchers and scholars interested in informetrics, scientometrics, and text mining. The hands-on perspective is also beneficial to advanced-level students in fields from computer science and statistics to information science.

  3. [Research advances on DNA extraction methods from peripheral blood mononuclear cells].

    Science.gov (United States)

    Wang, Xiao-Ying; Yu, Chen-Xi

    2014-10-01

    DNA extraction is a basic technology of molecular biology. The purity and the integrality of DNA structure are necessary for different experiments of gene engineering. As commonly used materials in the clinical detection, the fast, efficient isolation and extraction of genomic DNA from peripheral blood mononuclear cells is very important for the inspection and analysis of clinical blood. At present, there are many methods for extracting DNA, such as phenol-chloroform method, salting out method, centrifugal adsorption column chromatography method (artificial methods), magnetic beads (semi-automatic method) and DNA extraction kit. In this article, a brief review of the principle for existing DNA blood extraction method, the specific steps and the assessment of the specific methods briefly are summarized.

  4. Repeated Blood Pressure Measurements in Childhood in Prediction of Hypertension in Adulthood.

    Science.gov (United States)

    Oikonen, Mervi; Nuotio, Joel; Magnussen, Costan G; Viikari, Jorma S A; Taittonen, Leena; Laitinen, Tomi; Hutri-Kähönen, Nina; Jokinen, Eero; Jula, Antti; Cheung, Michael; Sabin, Matthew A; Daniels, Stephen R; Raitakari, Olli T; Juonala, Markus

    2016-01-01

    Hypertension may be predicted from childhood risk factors. Repeated observations of abnormal blood pressure in childhood may enhance prediction of hypertension and subclinical atherosclerosis in adulthood compared with a single observation. Participants (1927, 54% women) from the Cardiovascular Risk in Young Finns Study had systolic and diastolic blood pressure measurements performed when aged 3 to 24 years. Childhood/youth abnormal blood pressure was defined as above 90th or 95th percentile. After a 21- to 31-year follow-up, at the age of 30 to 45 years, hypertension (>140/90 mm Hg or antihypertensive medication) prevalence was found to be 19%. Carotid intima-media thickness was examined, and high-risk intima-media was defined as intima-media thickness >90th percentile or carotid plaques. Prediction of adulthood hypertension and high-risk intima-media was compared between one observation of abnormal blood pressure in childhood/youth and multiple observations by improved Pearson correlation coefficients and area under the receiver operating curve. When compared with a single measurement, 2 childhood/youth observations improved the correlation for adult systolic (r=0.44 versus 0.35, Pblood pressure. In addition, 2 abnormal childhood/youth blood pressure observations increased the prediction of hypertension in adulthood (0.63 for 2 versus 0.60 for 1 observation, P=0.003). When compared with 2 measurements, third observation did not provide any significant improvement for correlation or prediction (P always >0.05). A higher number of childhood/youth observations of abnormal blood pressure did not enhance prediction of adult high-risk intima-media thickness. Compared with a single measurement, the prediction of adult hypertension was enhanced by 2 observations of abnormal blood pressure in childhood/youth.

  5. Blood pressure measurement of all five fingers by strain gauge plethysmography

    DEFF Research Database (Denmark)

    Hirai, M; Nielsen, S L; Lassen, N A

    1976-01-01

    The aim of the present paper was to study the methodological problems involved in measuring systolic blood pressure in all five fingers by the strain gauge technique. In 24 normal subjects, blood pressure at the proximal phalanx of finger I and both at the proximal and the intermediate phalanx...... of the other fingers was measured using a 24-mm-wide cuff. Blood pressure at the proximal phalanx was higher than that at the intermediate phalanx in all fingers except finger V. The difference of blood pressure values corresponded well with circumference of the finger. In 15 normal subjects, blood pressure...... of the mean values was larter with the 27-mm-wide cuff than with the 24-mm-wide cuff, the 24-mm-wide cuff was considered to be most suitable for clinical use in fingers I, II, III, and IV. By using the 20-mm-wide cuff in finger V and the 24-mm-wide cuff in the other fingers, normal value of finger blood...

  6. Early development of arterial spin labeling to measure regional brain blood flow by MRI.

    Science.gov (United States)

    Koretsky, Alan P

    2012-08-15

    Two major avenues of work converged in the late 1980's and early 1990's to give rise to brain perfusion MRI. The development of anatomical brain MRI quickly had as a major goal the generation of angiograms using tricks to label flowing blood in macroscopic vessels. These ideas were aimed at getting information about microcirculatory flow as well. Over the same time course the development of in vivo magnetic resonance spectroscopy had as its primary goal the assessment of tissue function and in particular, tissue energetics. For this the measurement of the delivery of water to tissue was critical for assessing tissue oxygenation and viability. The measurement of the washin/washout of "freely" diffusible tracers by spectroscopic based techniques pointed the way for quantitative approaches to measure regional blood flow by MRI. These two avenues came together in the development of arterial spin labeling (ASL) MRI techniques to measure regional cerebral blood flow. The early use of ASL to measure brain activation to help verify BOLD fMRI led to a rapid development of ASL based perfusion MRI. Today development and applications of regional brain blood flow measurements with ASL continues to be a major area of activity.

  7. Measurement of streaming potentials of mammalian blood vessels, aorta and vena cava, in vivo.

    Science.gov (United States)

    Sawyer, P N; Himmelfarb, E; Lustrin, I; Ziskind, H

    1966-09-01

    Attempts to measure streaming potentials in large rabbit blood vessels in vivo have been carried out. Streaming potentials, V(89), were measured by the introduction of microelectrodes through the wall of the blood vessel at separations greater than 1 cm. The outputs from these electrodes fed through calomel cells were amplified and recorded directly by using an Electronics for Medicine photorecorder (White Plains, N. Y.). "Effective streaming currents" were determined by running the output through a low impedence galvanometer while simultaneously measuring the resistance of the circuit V(8) were, therefore, calculated from two measurements and compared. Flow through vessels studied was measured using two different electromagnetic flowmeters. The results indicate that V(8) present in both aorta and vena cava are of the order of 5 to 10 mv. By using the Helmholtz-Smoluchowski equation into which flow was reintegrated, the numbers yield zeta potentials approximating 0.1 to 0.4 v in both aorta and vena cava. This number approaches the apparent upper limit for zeta (actually "interfacial potentials") potentials in biological systems. The measured "i.f." potential is considered as the interreaction of several physical and metabolic factors operating at the blood intimal interface. The polarity of the potential suggests that the interface is negative with respect to the blood flowing through the vessel. Interfacial potential and related V(8) are discussed in terms of their possible importance as a mechanism for maintaining vascular homeostasis in the living animal.

  8. Measuring density and compressibility of white blood cells and prostate cancer cells by microchannel acoustophoresis

    DEFF Research Database (Denmark)

    Barnkob, Rune; Augustsson, Per; Magnusson, Cecilia

    2011-01-01

    to determine the density and compressibility of individual cells enables the prediction and alteration of the separation outcome for a given cell mixture. We apply the method on white blood cells (WBCs) and DU145 prostate cancer cells (DUCs) aiming to improve isolation of circulating tumor cells from blood......We present a novel method for the determination of density and compressibility of individual particles and cells undergoing microchannel acoustophoresis in an arbitrary 2D acoustic field. Our method is a critical advancement within acoustophoretic separation of biological cells, as the ability......, an emerging tool in the monitoring and characterizing of metastatic cancer....

  9. Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method

    Directory of Open Access Journals (Sweden)

    Junfeng Li

    2008-05-01

    Full Text Available A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914.

  10. Non-Invasive Glucose Measurement by Use of Metabolic Heat Conformation Method.

    Science.gov (United States)

    Tang, Fei; Wang, Xiaohao; Wang, Dongsheng; Li, Junfeng

    2008-05-21

    A non-invasive glucose measurement system based on the method of metabolic heat conformation (MHC) is presented in this paper. This system consists of three temperature sensors, two humidity sensors, an infrared sensor and an optical measurement device. The glucose level can be deduced from the quantity of heat dissipation, blood flow rate of local tissue and degree of blood oxygen saturation. The methodology of the data process and the measurement error are also analyzed. The system is applied in a primary clinical test. Compared with the results of a commercial automated chemistry analyzer, the correlation coefficient of the collected data from the system is 0.856. Result shows that the correlation coefficient improves when the factor of heat dissipated by evaporation of the skin is added in. A non-invasive method of measuring the blood flow rate of local tissue by heat transmission between skin and contacted conductor is also introduced. Theoretical derivation and numerical simulation are completed as well. The so-called normalized difference mean (NDM) is chosen to express the quantity of the blood flow rate. The correlation coefficient between the blood flow rates by this method and the results of a Doppler blood flow meter is equal to 0.914.

  11. The evaluation of blood fow in the face skin by LDF method

    Directory of Open Access Journals (Sweden)

    Lychagov V.V.

    2012-06-01

    Full Text Available

    Aims. The research aimed the studying and optimizing of the possibility of measuring microcirculatory of blood fow in human skin by laser Doppler fowmetry (LDF against the various topographic features of the peripheral blood supply of tissues. Materials and methods. 20 people of the age from 20 to 56 years without signs of skin lesions were examined by the LDF device. The LDF device has two radiation sources in the red light at a wavelength range of 650±30 nm and the near — infrared at a wavelength of 805±50 nm. The radiation was carried out with four receiving fbers arranged at distances of 1, 2, 3 and 4 mm from the illuminating fber. The state of microvasculature was studied at four points of skin — in the middle of the forehead, in the center of the right cheek and the symmetric point on the left cheek and chin area. We calculated the average values of microcirculation, its standard deviation and coeffcient of variation. Conclusions. By varying the distance from the illuminating fber to the receiving fber and the wavelength of incident light the values of the microcirculation in the different areas of healthy skin were estimated by laser Doppler fowmetry method (LDF. Tissue probes, the spatial localization of the LDF signal in the tissues and the effective depth of detection have been estimated by Monte Carlo method. It has been found out during the study that the LDF signal changes are directly related to the structural features of the structure of the microvasculature, the depth and density of functioning capillaries. The given method can be used to diagnose the state of biological object in the normal and pathological conditions, as well as evaluating the effectiveness of the treatment of various dermatoses.

  12. Method of optical self-mixing for pulse wave transit time in comparison with other methods and correlation with blood pressure

    Science.gov (United States)

    Meigas, Kalju; Lass, Jaanus; Kattai, Rain; Karai, Deniss; Kaik, Juri

    2004-07-01

    This paper is a part of research to develop convenient method for continuous monitoring of arterial blood pressure by non-invasive and non-oscillometric way. A simple optical method, using self-mixing in a diode laser, is used for detection of skin surface vibrations near the artery. These vibrations, which can reveal the pulsate propagation of blood pressure waves along the vasculature, are used for pulse wave registration. The registration of the Pulse Wave Transit Time (PWTT) is based on computing the time delay in different regions of the human body using an ECG as a reference signal. In this study, the comparison of method of optical self-mixing with other methods as photoplethysmographic (PPG) and bioimpedance (BI) for PWTT is done. Also correlation of PWTT, obtained with different methods, with arterial blood pressure is calculated. In our study, we used a group of volunteers (34 persons) who made the bicycle exercise test. The test consisted of cycling sessions of increasing workloads during which the HR changed from 60 to 180 beats per minute. In addition, a blood pressure (NIBP) was registered with standard sphygmomanometer once per minute during the test and all NIBP measurement values were synchronized to other signals to find exact time moments where the systolic blood pressure was detected (Korotkoff sounds starting point). Computer later interpolated the blood pressure signal in order to get individual value for every heart cycle. The other signals were measured continuously during all tests. At the end of every session, a recovery period was included until person's NIBP and heart rate (HR) normalized. As a result of our study it turned out that time intervals that were calculated from plethysmographic (PPG) waveforms were in the best correlation with systolic blood pressure. The diastolic pressure does not correlate with any of the parameters representing PWTT. The pulse wave signals measured by laser and piezoelectric transducer are very similar

  13. Automated counting of morphologically normal red blood cells by using digital holographic microscopy and statistical methods

    Science.gov (United States)

    Moon, Inkyu; Yi, Faliu

    2015-09-01

    In this paper we overview a method to automatically count morphologically normal red blood cells (RBCs) by using off-axis digital holographic microscopy and statistical methods. Three kinds of RBC are used as training and testing data. All of the RBC phase images are obtained with digital holographic microscopy (DHM) that is robust to transparent or semitransparent biological cells. For the determination of morphologically normal RBCs, the RBC's phase images are first segmented with marker-controlled watershed transform algorithm. Multiple features are extracted from the segmented cells. Moreover, the statistical method of Hotelling's T-square test is conducted to show that the 3D features from 3D imaging method can improve the discrimination performance for counting of normal shapes of RBCs. Finally, the classifier is designed by using statistical Bayesian algorithm and the misclassification rates are measured with leave-one-out technique. Experimental results show the feasibility of the classification method for calculating the percentage of each typical normal RBC shape.

  14. A new method for the determination of carboxyhemoglobin in blood of newborns. Possible clinical implications of elevated levels.

    Science.gov (United States)

    Zwart, A; Siepel, H; Heerspink, W

    1990-01-01

    Spectral differences between hemoglobin derivatives from adult-(HbA) and fetal-hemoglobin (HbF) make the accurate determination of carboxyhemoglobin (COHb) troublesome in blood of newborns. Only the newest dedicated instruments for the determination of COHb take these differences into account. However, since there are virtually no spectral differences between both hemoglobins in the deoxygenated state, reduction of neonatal blood with sodium dithionite eliminates that spectrophotometric error. Based on this principle, an easy, fast and accurate method for the determination of COHb in minimal amounts of blood was developed; equally well suited for blood of newborns and adults. The instrument used with this new method is a general purpose centrifugal clinical chemistry analyzer (COBAS-FARA, Roche, Basle, Switzerland). After the reduction of blood with sodium dithionite, a simple two component system (Hb and COHb) is formed, which can be spectrophotometrically quantitated by measuring at two suitable wavelengths, i.e., 579 nm and 534 nm. The COHb fraction is calculated with the help of: COHb % = 177.73.(A534/A579)-176.66. Comparison with the OSM3 Hemoximeter (Radiometer A/S, Denmark) for 145 adult blood samples with varying COHb levels (0-30%) yielded a mean difference in COHb % of about 0.06% (SD = 0.38). For fetal blood (N = 63) about the same difference was found when the OSM3 was used in the so-called fetal mode, while comparison with the regular adult mode yielded a difference of about 3.1%. This indicates that the new method is indeed not disturbed by the spectral differences between HbA and HbF.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Laser-diffraction slit rheometer to measure red blood cell deformability

    Science.gov (United States)

    Shin, S.; Ku, Y. H.; Park, M. S.; Moon, S. Y.; Jang, J. H.; Suh, J. S.

    2004-02-01

    The laser-diffraction technique has been applied to design a slit rheometer for measuring red blood cell deformability over a range of shear stress. Flow-rate and pressure-drop measurements are replaced with a measurement of pressure variation with time. Using a precision pressure transducer, one can measure the variation of pressure in the vacuum chamber, p(t), from which the shear stress and shear rate are mathematically calculated. In addition, a laser beam traverses a diluted blood suspension and is diffracted by red blood cells (RBCs) in the volume. The diffraction patterns are captured by a charge coupled device-video camera, linked to a frame grabber integrated with a computer. When deforming under decreasing shear stress, RBCs change gradually from the prolate ellipsoid towards a circular biconcave morphology. The elongation index as a measure of RBC deformability is determined from an isointensity curve in the diffraction pattern using an ellipse-fitting program. The advantages of this design are simplicity, i.e., ease of operation and no moving parts, low cost, short operating time, and the disposable kit which is in contact with the blood sample.

  16. Sitting and standing blood pressure measurements are not accurate for the diagnosis of orthostatic hypotension.

    LENUS (Irish Health Repository)

    Cooke, J

    2012-01-31

    INTRODUCTION: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH. DESIGN: Retrospective test of diagnostic accuracy. METHODS: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard. Both tests happened within 5 min of each other and patients underwent no intervention between tests. RESULTS: From a total of 1452 consecutive HUTs, we identified 730 with pre-test measures of sitting and standing BP. The mean age of this group was 70.57 years (SD = 15.1), 62% were female. The sensitivity of sit-stand testing was calculated as 15.5%, specificity as 89.9%, positive predictive value as 61.7%, negative predictive value as 50.2% and the likelihood ratio as 1.6. The area under the Receiver Operator Curve was 0.564. CONCLUSION: We have demonstrated that sit-stand testing for OH has very low diagnostic accuracy. We recommend that the more time-consuming reference standard method of diagnosis be used if the condition is suspected.

  17. Measurement and Hemodialysis Effect of Complex Relative Permittivity for Blood of Kidney Patients Using Open-Ended Coaxial Measurement Probe

    Science.gov (United States)

    Takeda, Akira; Takata, Kazuyuki; Nagao, Hirotomo; Wang, Jianqing; Fujiwara, Osamu

    Before evaluating the quality of hemodialysis from the limited volume of human blood using a commercially available open-ended coaxial probe, we previously measured the complex relative permittivity of pure water from 200 MHz to 6 GHz with respect to its measured liquid volume, and revealed that 1.9 ml water in a beaker with a diameter of 24 mm and a depth of 2 mm gives a variation within ±0.5 % for the real part and ±7 % for the imaginary part. Based on the above finding, we measured the dielectric properties of 2.5 ml whole blood at 25°C for 10 normal healthy subjects and 9 hemodialysis patients. The measured results on healthy subjects show good agreement with the data reported by Gabriel for human blood at 37°C, while they provide different dispersion characteristics of straight lines for their Cole-Cole plots. The measured results on the patients give further different dispersion characteristics in comparison with the healthy subjects. In order to investigate the above differences statistically, the student t-test was conducted to reveal that permittivity at infinite frequency for the Cole-Cole plots is significantly different with a level of 1 % among its averaged values for normal healthy subjects and patients before dialysis.

  18. Thresholds for Diagnosing Hypertension Based on Automated Office Blood Pressure Measurements and Cardiovascular Risk.

    Science.gov (United States)

    Myers, Martin G; Kaczorowski, Janusz; Paterson, J Michael; Dolovich, Lisa; Tu, Karen

    2015-09-01

    The risk of cardiovascular events in relation to blood pressure is largely based on readings taken with a mercury sphygmomanometer in populations which differ from those of today in terms of hypertension severity and drug therapy. Given replacement of the mercury sphygmomanometer with electronic devices, we sought to determine the blood pressure threshold for a significant increase in cardiovascular risk using a fully automated device, which takes multiple readings with the subject resting quietly alone. Participants were 3627 community-dwelling residents aged >65 years untreated for hypertension. Automated office blood pressure readings were obtained in a community pharmacy with subjects seated and undisturbed. This method for recording blood pressure produces similar readings in different settings, including a pharmacy and family doctor's office providing the above procedures are followed. Subjects were followed for a mean (SD) of 4.9 (1.0) years for fatal and nonfatal cardiovascular events. Adjusted hazard ratios (95% confidence intervals) were computed for 10 mm Hg increments in blood pressure (mm Hg) using Cox proportional hazards regression and the blood pressure category with the lowest event rate as the reference category. A total of 271 subjects experienced a cardiovascular event. There was a significant (P=0.02) increase in the hazard ratio of 1.66 (1.09, 2.54) at a systolic blood pressure of 135 to 144 and 1.72 (1.21, 2.45; P=0.003) at a diastolic blood pressure of 80 to 89. A significant (P=0.03) increase in hazard ratio of 1.73 (1.04, 2.86) occurred with a pulse pressure of 80 to 89. These findings are consistent with a threshold of 135/85 for diagnosing hypertension in older subjects using automated office blood pressure.

  19. Micro-particle image velocimetry for velocity profile measurements of micro blood flows.

    Science.gov (United States)

    Pitts, Katie L; Fenech, Marianne

    2013-04-25

    Micro-particle image velocimetry (μPIV) is used to visualize paired images of micro particles seeded in blood flows. The images are cross-correlated to give an accurate velocity profile. A protocol is presented for μPIV measurements of blood flows in microchannels. At the scale of the microcirculation, blood cannot be considered a homogeneous fluid, as it is a suspension of flexible particles suspended in plasma, a Newtonian fluid. Shear rate, maximum velocity, velocity profile shape, and flow rate can be derived from these measurements. Several key parameters such as focal depth, particle concentration, and system compliance, are presented in order to ensure accurate, useful data along with examples and representative results for various hematocrits and flow conditions.

  20. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Seo, Seung-Jun; Lim, Jae-Hong; Lee, Sang-Joon

    2015-03-06

    Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases.

  1. Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model

    Directory of Open Access Journals (Sweden)

    Babbs Charles F

    2012-08-01

    Full Text Available Abstract Background The oscillometric method of measuring blood pressure with an automated cuff yields valid estimates of mean pressure but questionable estimates of systolic and diastolic pressures. Existing algorithms are sensitive to differences in pulse pressure and artery stiffness. Some are closely guarded trade secrets. Accurate extraction of systolic and diastolic pressures from the envelope of cuff pressure oscillations remains an open problem in biomedical engineering. Methods A new analysis of relevant anatomy, physiology and physics reveals the mechanisms underlying the production of cuff pressure oscillations as well as a way to extract systolic and diastolic pressures from the envelope of oscillations in any individual subject. Stiffness characteristics of the compressed artery segment can be extracted from the envelope shape to create an individualized mathematical model. The model is tested with a matrix of possible systolic and diastolic pressure values, and the minimum least squares difference between observed and predicted envelope functions indicates the best fit choices of systolic and diastolic pressure within the test matrix. Results The model reproduces realistic cuff pressure oscillations. The regression procedure extracts systolic and diastolic pressures accurately in the face of varying pulse pressure and arterial stiffness. The root mean squared error in extracted systolic and diastolic pressures over a range of challenging test scenarios is 0.3 mmHg. Conclusions A new algorithm based on physics and physiology allows accurate extraction of systolic and diastolic pressures from cuff pressure oscillations in a way that can be validated, criticized, and updated in the public domain.

  2. Measurement of mercury species in human blood using triple spike isotope dilution with SPME-GC-ICP-DRC-MS.

    Science.gov (United States)

    Sommer, Yuliya L; Verdon, Carl P; Fresquez, Mark R; Ward, Cynthia D; Wood, Elliott B; Pan, Yi; Caldwell, Kathleen L; Jones, Robert L

    2014-08-01

    The measurement of different mercury compounds in human blood can provide valuable information about the type of mercury exposure. To this end, our laboratory developed a biomonitoring method for the quantification of inorganic (iHg), methyl (MeHg), and ethyl (EtHg) mercury in whole blood using a triple-spike isotope dilution (TSID) quantification method employing capillary gas chromatography (GC) and inductively coupled dynamic reaction cell mass spectrometry (ICP-DRC-MS). We used a robotic CombiPAL(®) sample handling station featuring twin fiber-based solid-phase microextraction (SPME) injector heads. The use of two SPME fibers significantly reduces sample analysis cycle times making this method very suitable for high sample throughput, which is a requirement for large public health biomonitoring studies. Our sample preparation procedure involved solubilization of blood samples with tetramethylammonium hydroxide (TMAH) followed by the derivatization with sodium tetra(n-propyl)borate (NaBPr(4)) to promote volatility of mercury species. We thoroughly investigated mercury species stability in the blood matrix during the course of sample treatment and analysis. The method accuracy for quantifying iHg, MeHg, and EtHg was validated using NIST standard reference materials (SRM 955c level 3) and the Centre de Toxicologie du Québec (CTQ) proficiency testing (PT) samples. The limit of detection (LOD) for iHg, MeHg, and EtHg in human blood was determined to be 0.27, 0.12, and 0.16 μg/L, respectively.

  3. Optical methods for measurements of skin penetration.

    Science.gov (United States)

    Gotter, B; Faubel, W; Neubert, R H H

    2008-01-01

    Fourier transform infrared photoacoustic (PAS), photothermal deflection (PDS) and Raman spectroscopy belong to the modern innovative noninvasive analytical tools that are beginning to be recognized as highly potential techniques for the noninvasive study of biological tissues and human skin under in vivo conditions. They can be applied to obtain information regarding the molecular composition of the skin down to several hundred micrometers below the skin surface. All three methods allow depth-resolved investigations. While PAS and PDS use a frequency modulation of the excitation beam to reach deeper regions in the sample, the principle of confocal Raman microspectroscopy (CRM) is a movement of the specimen in the focal plane. In consideration of depth measurements PAS and PDS complete the applicable spectrum of CRM, since Raman microscopy requires particular transparent materials.

  4. Doppler measurements of feto-placental blood stream in pregnant smokers

    Directory of Open Access Journals (Sweden)

    Gordana Bogdanović

    2011-12-01

    Full Text Available Introduction: Doppler analysis of the feto-placental and fetal circulation give dynamic information on the condition of the bloodstream during pregnancy, and early detection of fetal hypoxia. The objectives of the study were: testing whether there is influence of smoking on feto-placental circulation; determining whether there is a link to a number of smoked cigarettes during the day; assessing the benefits of Doppler ultrasonographic screening in detection of fetal hypoxia in pregnant women who smoke during pregnancy.Methods: 300 pregnancies were included in the prospective research. With regard to a number of smoked cigarettes the pregnant women were divided into three groups: I. the first group (moderate smokers consisted of 100 pregnant women who smoked up to 15 cigarettes a day during pregnancy; II. the second group (heavy smokers 100 pregnant women who smoked more than 15 cigarettes a day during pregnancy and III. the third group (control group 100 pregnant women who did not smoke during pregnancy. All pregnant women underwent Doppler measurements of blood circulation (determination of resistance index – RI in the umbilical artery, fetal aorta and middle cerebral artery.Results: The intensity of smoking has influence to circulation because RI in the umbilical artery and fetal aorta is increased and RI is decreased in the middle cerebral artery in pregnant women heavy smokers in comparison to pregnant women moderate smokers.Conclusion: Doppler sonography of the blood vessels could have an important role in detection of hypoxia and monitoring of the condition of the fetus of pregnant women who smoked during pregnancy.

  5. Pose measurement method based on geometrical constraints

    Institute of Scientific and Technical Information of China (English)

    Zimiao Zhang; Changku Sun; Pengfei Sun; Peng Wang

    2011-01-01

    @@ The pose estimation method based on geometric constraints is studied.The coordinates of the five feature points in the camera coordinate system are calculated to obtain the pose of an object on the basis of the geometric constraints formed by the connective lines of the feature points and the coordinates of the feature points on the CCD image plane; during the solution process,the scaling and orthography projection model is used to approximate the perspective projection model.%The pose estimation method based on geometric constraints is studied. The coordinates of the five feature points in the camera coordinate system are calculated to obtain the pose of an object on the basis of the geometric constraints formed by the connective lines of the feature points and the coordinates of the feature points on the CCD image plane; during the solution process, the scaling and orthography projection model is used to approximate the perspective projection model. The initial values of the coordinates of the five feature points in the camera coordinate system are obtained to ensure the accuracy and convergence rate of the non-linear algorithm. In accordance with the perspective projection characteristics of the circular feature landmarks, we propose an approach that enables the iterative acquisition of accurate target poses through the correction of the perspective projection coordinates of the circular feature landmark centers. Experimental results show that the translation positioning accuracy reaches ±0.05 mm in the measurement range of 0-40 mm, and the rotation positioning accuracy reaches ±0.06° in the measurement range of 4°-60°.

  6. Diurnal blood pressure variability and physical activity measured electronically and by diary.

    Science.gov (United States)

    Gretler, D D; Carlson, G F; Montano, A V; Murphy, M B

    1993-02-01

    In order for 24 h ambulatory blood pressure monitoring (ABPM) to be useful in clinical decision making, it is necessary to quantify ambient physical activity and to develop appropriate norms of ambulatory pressure for different levels of activity. The present study has compared the predictive value of physical activity determined by an electronic activity monitor or a written diary, for concomitantly recorded blood pressure during ABPM in healthy normotensive subjects. Each subject wore four activity monitors, on the right and left wrists, on the left ankle and at the waist, respectively. Linear regression analysis was performed for each subject to determine the correlation between ABPM data (systolic and diastolic blood pressure and heart rate) and activity data (obtained from diaries and the four monitors). Significant differences in the degree of correlation were found for both the location of the activity monitor and the time (1/2, 2, 5, 10, 15, and 30 min preceding blood pressure measurement) over which activity was averaged (P accounting for 18 to 69% (mean 36 +/- 5%) of systolic blood pressure variation. Diaries performed similarly in these well-motivated subjects. It is concluded that because of the significant interaction between activity and blood pressure, ABPM data should be interpreted only in the light of concomitant activity data.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Field methods for measuring concentrated flow erosion

    Science.gov (United States)

    Castillo, C.; Pérez, R.; James, M. R.; Quinton, J. N.; Taguas, E. V.; Gómez, J. A.

    2012-04-01

    Many studies have stressed the importance of gully erosion in the overall soil loss and sediment yield of agricultural catchments, for instance in recent years (Vandaele and Poesen, 1995; De Santisteban et al., 2006; Wu el al, 2008). Several techniques have been used for determining gully erosion in field studies. The conventional techniques involved the use of different devices (i.e. ruler, pole, tape, micro-topographic profilers, total station) to calculate rill and gully volumes through the determination of cross sectional areas and length of reaches (Casalí et al, 1999; Hessel and van Asch, 2003). Optical devices (i.e. laser profilemeters) have also been designed for the purpose of rapid and detailed assessment of cross sectional areas in gully networks (Giménez et al., 2009). These conventional 2d methods provide a simple and un-expensive approach for erosion evaluation, but are time consuming to carry out if a good accuracy is required. On the other hand, remote sensing techniques are being increasingly applied to gully erosion investigation such as aerial photography used for big-scale, long-term, investigations (e.g. Martínez-Casasnovas et al., 2004; Ionita, 2006), airborne and terrestrial LiDAR datasets for gully volume evaluation (James et al., 2007; Evans and Lindsay, 2010) and recently, major advances in 3D photo-reconstruction techniques (Welty et al. 2010, James et al., 2011). Despite its interest, few studies simultaneously compare the accuracies of the range of conventional and remote sensing techniques used, or define the most suitable method for a particular scale, given and time and cost constraints. That was the reason behind the International Workshop Innovations in the evaluation and measurement of rill and gully erosion, held in Cordoba in May 2011 and from which derive part of the materials presented in this abstract. The main aim of this work was to compare the accuracy and time requirements of traditional (2D) and recently developed

  8. Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo

    Science.gov (United States)

    Han, Guang; Liu, Jin; Liu, Rong; Xu, Kexin

    2016-10-01

    Position-based reference measurement method is taken as one of the most promising method in non-invasive measurement of blood glucose based on spectroscopic methodology. Selecting an appropriate source-detector separation as the reference position is important for deducting the influence of background change and reducing the loss of useful signals. Our group proposed a special source-detector separation named floating-reference position where the signal contains only background change, that is to say, the signal at this source-detector separation is uncorrelated with glucose concentration. The existence of floating-reference position has been verified in a three layer skin by Monte Carlo simulation and in the in vitro experiment. But it is difficult to verify the existence of floating-reference position on the human body because the interference is more complex during in vivo experiment. Aiming at this situation, this paper studies the determination of the best reference position on human body by collecting signals at several source-detector separations on the palm and measuring the true blood glucose levels during oral glucose tolerance test (OGTT) experiments of 3 volunteers. Partial least square (PLS) calibration model is established between the signals at every source-detector separation and its corresponding blood glucose levels. The results shows that the correlation coefficient (R) between 1.32 mm to 1.88 mm is lowest and they can be used as reference for background correction. The signal of this special position is important for improving the accuracy of near-infrared non-invasive blood glucose measurement.

  9. Comparison between Digital Image Processing and Spectrophotometric Measurements Methods

    Directory of Open Access Journals (Sweden)

    Bogdan Adnan HAIFA

    2011-03-01

    Full Text Available Background: Spectrophotometer is a very common instrument in various scientific fields and gives accurate information about light absorbance and transmittance through materials using monochromatic light source. Though, devices used in spectrophotometry can be quite expensive, using components with high technical specifications and the procedure itself is time consuming. Regular digital image acquisition instruments like scanners and cameras on the other hand uses very cheap electronic components to record the information on 3 wide band channels (Red, Green, Blue. Purpose: This paper studies the possibility of correlating the measurements from the spectrophotometer with raw data from digital image acquisition instruments. Materials and Methods: Because the results will be used in protein electrophoresis, we prepared o set of plates with blood serum in different dilutions, stained with Coomassie Brilliant Blue. The absorbance of the resulting plates has been measured using a spectrophotometer and after that, the plates were scanned with a regular office scanner. The digital image was converted in different color spaces (gray scale, RGB, HSV, HSL, CIEXYZ and CIELAB using custom developed software in C++. We statistically measured the correlation coefficient of different parameters from the color space with the absorption measured with the spectrophotometer. Results and Discussion: The findings of this work show that a consumer digital scanner can be used as a fast and inexpensive alternative to spectrophotometers. This offers the possibility of using scanned images of protein electrophoresis to make quantitative estimations regarding the proteinogram.

  10. CALF BLOOD-FLOW AND POSTURE - DOPPLER ULTRASOUND MEASUREMENTS DURING AND AFTER EXERCISE

    NARCIS (Netherlands)

    VANLEEUWEN, BE; BARENDSEN, GJ; LUBBERS, J; DEPATER, L

    1992-01-01

    To investigate the joint effects of body posture and calf muscle pump, the calf blood flow of eight healthy volunteers was measured with pulsed Doppler equipment during and after 3 min of rhythmic exercise on a calf ergometer in the supine, sitting, and standing postures. Muscle contractions serious

  11. Classification of peripheral occlusive arterial diseases based on symptoms, signs and distal blood pressure measurements

    DEFF Research Database (Denmark)

    Tønnesen, K H; Noer, Ivan; Paaske, William

    1980-01-01

    Systolic blood pressures at toe and ankle were measured in 459 consecutive patients with occlusive arterial disease. Fifty-eight per cent had intermittent claudication with arterial disease of all degrees of severity. Seventeen per cent complained of rest pain having toe systolic pressures below 30...

  12. From pioneering to implementing automated blood pressure measurement in clinical practice: Thomas Pickering's legacy

    DEFF Research Database (Denmark)

    Stolarz-Skrzypek, Katarzyna; Thijs, Lutgarde; Wizner, Barbara;

    2010-01-01

    Thomas G. Pickering spent most of his scientific career in carrying out research on clinical hypertension and blood pressure (BP) measurement. In our review of Pickering's seminal work, we first focused on white-coat hypertension and masked hypertension, two terms that he had introduced. Next, we...

  13. Acute Traumatic Coagulopathy: Whole Blood Thrombelastography Measures the Tip of the Iceberg

    Science.gov (United States)

    2015-01-01

    Acute traumatic coagulopathy: Whole blood thrombelastography measures the tip of the iceberg James Eric Campbell, PhD, James Keith Aden, PhD, and...Plotkin AJ, Wade CE, Jenkins DH, Smith KA, Noe JC, Park MS, Perkins JG, Holcomb JB. A reduction in clot formation rate and strength assessed by

  14. Validity of blood flow measurement using 320 multi-detectors CT and first-pass distribution theory: a phantom study

    Science.gov (United States)

    Chen, Jun; Yu, Xuefang; Xu, Shaopeng; Zhou, Kenneth J.

    2015-03-01

    To evaluate the feasibility of measuring the myocardial blood flow using 320 row detector CT by first-pass technique. Heart was simulated with a container that was filled with pipeline of 3mm diameter; coronary artery was simulated with a pipeline of 2 cm diameter and connected with the simulated heart. The simulated coronary artery was connected with a big container with 1500 ml saline and 150ml contrast agent. One pump linking with simulated heart will withdraw with a speed of 10 ml/min, 15 ml/min, 20 ml/min, 25 ml/min and 30 ml/min. First CT scan starts after 30 s of pumpback with certain speed. The second CT scan starts 5 s after first CT scans. CT images processed as follows: The second CT scan images subtract first CT scan images, calculate the increase of CT value of simulated heart and the CT value of the unit volume of simulated coronary artery and then to calculate the total inflow of myocardial blood flow. CT myocardial blood flows were calculated as: 0.94 ml/s, 2.09 ml/s, 2.74 ml/s, 4.18 ml/s, 4.86 ml/s. The correlation coefficient is 0.994 and r2 = 0.97. The method of measuring the myocardial blood flow using 320 row detector CT by 2 scans is feasible. It is possible to develop a new method for quantitatively and functional assessment of myocardial perfusion blood flow with less radiation does.

  15. Impact of red blood cell transfusion on global and regional measures of oxygenation.

    Science.gov (United States)

    Roberson, Russell S; Bennett-Guerrero, Elliott

    2012-01-01

    Anemia is common in critically ill patients. Although the goal of transfusion of red blood cells is to increase oxygen-carrying capacity, there are contradictory results about whether red blood cell transfusion to treat moderate anemia (e.g., hemoglobin 7-10 g/dL) improves tissue oxygenation or changes outcomes. Whereas increasing levels of anemia eventually lead to a level of critical oxygen delivery, increased cardiac output and oxygen extraction are homeostatic mechanisms the body uses to prevent a state of dysoxia in the setting of diminished oxygen delivery due to anemia. In order for cardiac output to increase in the face of anemia, normovolemia must be maintained. Transfusion of red blood cells increases blood viscosity, which may actually decrease cardiac output (barring a state of hypovolemia prior to transfusion). Studies have generally shown that transfusion of red blood cells fails to increase oxygen uptake unless oxygen uptake/oxygen delivery dependency exists (e.g., severe anemia or strenuous exercise). Recently, near-infrared spectroscopy, which approximates the hemoglobin saturation of venous blood, has been used to investigate whether transfusion of red blood cells increases tissue oxygenation in regional tissue beds (e.g., brain, peripheral skeletal muscle). These studies have generally shown increases in near-infrared spectroscopy derived measurements of tissue oxygenation following transfusion. Studies evaluating the effect of transfusion on the microcirculation have shown that transfusion increases the functional capillary density. This article will review fundamental aspects of oxygen delivery and extraction, and the effects of red blood cell transfusion on tissue oxygenation as well as the microcirculation.

  16. Measurements of Intracellular Ca2+ Content and Phosphatidylserine Exposure in Human Red Blood Cells: Methodological Issues

    Directory of Open Access Journals (Sweden)

    Mauro C. Wesseling

    2016-06-01

    Full Text Available Background/Aims: The increase of the intracellular Ca2+ content as well as the exposure of phosphatidylserine (PS on the outer cell membrane surface after activation of red blood cells (RBCs by lysophosphatidic acid (LPA has been investigated by a variety of research groups. Carrying out experiments, which we described in several previous publications, we observed some discrepancies when comparing data obtained by different investigators within our research group and also between batches of LPA. In addition, we found differences comparing the results of double and single labelling experiments (for Ca2+ and PS. Furthermore, the results of PS exposure depended on the fluorescent dye used (annexin V-FITC versus annexin V alexa fluor® 647. Therefore, it seems necessary to investigate these methodological approaches in more detail to be able to quantify results and to compare data obtained by different research groups. Methods: The intracellular Ca2+ content and the PS exposure of RBCs separated from whole blood have been investigated after treatment with LPA (2.5 µM obtained from three different companies (Sigma-Aldrich, Cayman Chemical Company, and Santa Cruz Biotechnology Inc.. Fluo-4 and x-rhod-1 have been used to detect intracellular Ca2+ content, annexin V alexa fluor® 647 and annexin V-FITC have been used for PS exposure measurements. Both parameters (Ca2+ content, PS exposure were studied using flow cytometry and fluorescence microscopy. Results: The percentage of RBCs showing increased intracellular Ca2+ content as well as PS exposure changes significantly between different LPA manufacturers as well as on the condition of mixing of LPA with the RBC suspension. Furthermore, the percentage of RBCs showing PS exposure is reduced in double labelling compared to single labelling experiments and depends also on the fluorescent dye used. Finally, data on Ca2+ content are slightly affected whereas PS exposure data are not affected significantly

  17. [Measurement of cerebral blood flow by thermal diffusion using a flow probe with a Peltier stack].

    Science.gov (United States)

    Yamagata, S; Kikuchi, H; Hashimoto, K; Minamikawa, J; Watanabe, Y

    1987-05-01

    In order to evaluate the blood flow by means of thermal diffusion, relationship between blood flow and parameters induced by thermal diffusion was investigated. Flow probe employed for measurement by thermal diffusion incorporated a Peltier stack which contained a small semiconductor and two L-shaped gold plates. These two plates were attached to both sides of the semiconductor by one side of each gold plate and the other side was surfaced with a tissue to be measured. Temperature gradient is created with current applied to the Peltier stack between two plates, one cooled and the other heated, and it is affected only by tissue blood flow. Two kinds of parameters of thermal diffusion were subjected to compare to blood flow. One was temperature gradient when the constant current was applied to the Peltier stack. The other was a current required to maintain a definite temperature gradient which was determined before hand. From the theoretical principle in thermodynamics, the correlations between blood flow and each of thermal diffusion parameters were defined by the following equations: (Formula: see text) where F is blood flow, delta V is voltage converted from temperature gradient, and Ci and Cv are constants. Each of phi v and phi i indicates the characteristics of each probe. Experimental study was carried out to confirm the above relationship using cortex of experimental animals. Under the general anesthesia, a cat was placed in prone position. After the craniotomy, dura mater was opened and a small flow probe, 10 mm in diameter, 5 mm in height and 5 g in weight, was placed on the cortex and blood flow was continuously evaluated by two parameters.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Cerebral Blood Flow and Transcranial Doppler Sonography Measurements of CO(2)-Reactivity in Acute Traumatic Brain Injured Patients

    DEFF Research Database (Denmark)

    Reinstrup, Peter; Ryding, Erik Hilmer; Asgeirsson, Bogi;

    2013-01-01

    BACKGROUND: Cerebral blood flow (CBF) measurements are helpful in managing patients with traumatic brain injury (TBI), and testing the cerebrovascular reactivity to CO(2) provides information about injury severity and outcome. The complexity and potential hazard of performing CBF measurements...... limits routine clinical use. An alternative approach is to measure the CBF velocity using bedside, non-invasive, and transcranial Doppler (TCD) sonography. This study was performed to investigate if TCD is a useful alternative to CBF in patients with severe TBI. METHOD: CBF and TCD flow velocity...... measurements and cerebrovascular reactivity to hypocapnia were simultaneously evaluated in 27 patients with acute TBI. Measurements were performed preoperatively during controlled normocapnia and hypocapnia in patients scheduled for hematoma evacuation under general anesthesia. MAIN FINDING AND CONCLUSION...

  19. Enhanced Stability of Blood Matrices Using a Dried Sample Spot Assay to Measure Human Butyrylcholinesterase Activity and Nerve Agent Adducts

    Science.gov (United States)

    Perez, Jonas W.; Pantazides, Brooke G.; Watson, Caroline M.; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.

    2015-01-01

    Dried matrix spots are safer to handle and easier to store than wet blood products, but factors such as intra-spot variability and unknown sample volumes have limited their appeal as a sampling format for quantitative analyses. In this work, we introduce a dried spot activity assay for quantifying butyrylcholinesterase (BChE) specific activity which is BChE activity normalized to the total protein content in a sample spot. The method was demonstrated with blood, serum, and plasma spotted on specimen collection devices (cards) which were extracted to measure total protein and BChE activity using a modified Ellman assay. Activity recovered from dried spots was ∼80% of the initial spotted activity for blood and >90% for plasma and serum. Measuring total protein in the sample and calculating specific activity substantially improved quantification and reduced intra-spot variability. Analyte stability of nerve agent adducts was also evaluated, and the results obtained via BChE-specific activity measurements were confirmed by quantification of BChE adducts using a previously established LC-MS/MS method. The spotted samples were up to 10-times more resistant to degradation compared to unspotted control samples when measuring BChE inhibition by the nerve agents sarin and VX. Using this method, both BChE activity and adducts can be accurately measured from a dried sample spot. This use of a dried sample spot with normalization to total protein is robust, demonstrates decreased intra-spot variability without the need to control for initial sample volume, and enhances analyte stability. PMID:25955132

  20. Strategies for classifying patients based on office, home, and ambulatory blood pressure measurement.

    Science.gov (United States)

    Zhang, Lu; Li, Yan; Wei, Fang-Fei; Thijs, Lutgarde; Kang, Yuan-Yuan; Wang, Shuai; Xu, Ting-Yan; Wang, Ji-Guang; Staessen, Jan A

    2015-06-01

    Hypertension guidelines propose home or ambulatory blood pressure monitoring as indispensable after office measurement. However, whether preference should be given to home or ambulatory monitoring remains undetermined. In 831 untreated outpatients (mean age, 50.6 years; 49.8% women), we measured office (3 visits), home (7 days), and 24-h ambulatory blood pressures. We applied hypertension guidelines for cross-classification of patients into normotension or white-coat, masked, or sustained hypertension. Based on office and home blood pressures, the prevalence of white-coat, masked, and sustained hypertension was 61 (10.3%), 166 (20.0%), and 162 (19.5%), respectively. Using daytime (from 8 am to 6 pm) instead of home blood pressure confirmed the cross-classification in 575 patients (69.2%), downgraded risk from masked hypertension to normotension (n=24) or from sustained to white-coat hypertension (n=9) in 33 (4.0%), but upgraded risk from normotension to masked hypertension (n=179) or from white-coat to sustained hypertension (n=44) in 223 (26.8%). Analyses based on 24-h ambulatory blood pressure were confirmatory. In adjusted analyses, both the urinary albumin-to-creatinine ratio (+20.6%; confidence interval, 4.4-39.3) and aortic pulse wave velocity (+0.30 m/s; confidence interval, 0.09-0.51) were higher in patients who moved up to a higher risk category. Both indexes of target organ damage and central augmentation index were positively associated (P≤0.048) with the odds of being reclassified. In conclusion, for reliably diagnosing hypertension and starting treatment, office measurement should be followed by ambulatory blood pressure monitoring. Using home instead of ambulatory monitoring misses the high-risk diagnoses of masked or sustained hypertension in over 25% of patients.

  1. Effect of exosome isolation methods on physicochemical properties of exosomes and clearance of exosomes from the blood circulation.

    Science.gov (United States)

    Yamashita, Takuma; Takahashi, Yuki; Nishikawa, Makiya; Takakura, Yoshinobu

    2016-01-01

    Exosomes, which are expected to be delivery systems for biomolecules such as nucleic acids, are collected by several methods. However, the effect of exosome isolation methods on the characteristics of exosomes as drug carriers, such as recovery efficiency after sterile filtration and pharmacokinetics, has not been investigated despite the importance of these characteristics for the development of exosome-based delivery systems. In the present study, exosomes collected from murine melanoma B16-BL6 cells by several methods were compared with respect to dispersibility, recovery rate after filtering, and clearance from the blood circulation in mice. The exosomes were collected by three ultracentrifugation-based methods: simple ultracentrifugation/pelleting (pelleting method), ultracentrifugation with an iodixanol cushion (cushion method), and ultracentrifugation on an iodixanol density gradient (gradient method). The isolation methods had little effect on the particle number of exosomes. In contrast, transmission electron microscopy observation and size distribution measurement using tunable resistive pulse sensing indicated that the exosomes of the gradient method were more dispersed than the others. The exosomes were labeled with Gaussia luciferase and intravenously injected into mice. Clearance of injected exosomes from the blood circulation did not significantly change with isolation methods. When the exosomes were filtered using a 0.2-μm filter, the recovery rate was 82% for the exosomes of the gradient method, whereas it was less than 50% for the others. These results indicate that the exosome isolation method markedly affects the dispersibility and filtration efficiency of the exosomes.

  2. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    Science.gov (United States)

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  3. Measurement of myocardial blood flow with oxygen-15 labelled water: comparison of different administration protocols.

    Science.gov (United States)

    Hermansen, F; Rosen, S D; Fath-Ordoubadi, F; Kooner, J S; Clark, J C; Camici, P G; Lammertsma, A A

    1998-07-01

    Positron emission tomography (PET) in conjunction with C15O2 or H215O can be used to measure myocardial blood flow (MBF) and tissue fraction (TF), i.e. the fraction of the tissue mass in the volume of the region of interest. However, with C15O2 inhalation, the tissue fraction in the septum is overestimated. Bolus injection of H215O together with arterial cannulation gives very precise results but is invasive. The purpose of this study was to develop a method which circumvents these problems. A four-parameter model with parameters for MBF, TF and spill-over fractions from both left and right ventricular cavities was developed. This method was compared with a three-parameter model (no right ventricular cavity spill-over) in both septal and non-septal regions of interest for three different administration protocols: bolus injection of H215O, infusion of H215O and inhalation of C15O2. It was found that MBF can be measured with intravenous administration of H215O without the requirement for arterial cannulation. The four-parameter protocol with bolus injection was stable in clinical studies. The four-parameter model proved essential for the septum, where it gave highly significantly better fits than did the three-parameter model (P<0.00003 in each of 15 subjects). Administration of H215O together with this four-parameter model also circumvented the problem of overestimation of TF in the septum seen with C15O2 inhalation. In addition, the radiation dose of H215O protocols is lower than that of C15O2 inhalation. Using a left atrial input curve instead of a left ventricular cavity input curve gave the same mean MBF and TF.

  4. RSI: oxygen consumption, blood flow, and reoxygenation in patients suffering RSI measured by noninvasive optical spectroscopy

    Science.gov (United States)

    Thijssen, Dick H. J.; van Uden, Caro J. T.; Krijgsman, Hans; Colier, Willy N. J. M.

    2003-07-01

    Background: Repetitive Strain Injury (RSI) is a major problem in nowadays health care and creates high financial costs and personal distress. Average prevalence rates in the Netherlands vary from 20-40% of the working population. Insight into the patho-physiological mechanism of RSI is important in order to establish adequate treatment and prevention programs. Objective: The aim of this study was to gain insight in muscle oxygen consumption (mVO2), blood flow (BF), and reoxygenation (ReOx) in the forearm of computer workers with stage III Repetitive Strain Injury (RSI). Method: We have used continuous wave infrared spectroscopy (NIRS) to measure these variables. Measurements were conducted on the extensor and flexor muscle in both arms as well in RSI-patients (n=10) as in control subjects (n=21). A protocol of increased isometric repetitive contraction in a handgrip ergonometer was used with increasing levels of strength. Results: mVO2 in the extensor muscle in RSI-subjects (dominant side) was increased compared to control subjects and compared to the non-dominant side (pmuscle). However, there was a tendency towards statistical significance (p=0.065). BF in rest was equal in both groups, however after exercise it tended to be increased. Half-time recovery (T ») was measured during only one part of the protocol and it was significantly increased (p<0.05). Conclusion: mVO2 in RSI is impaired. BF and ReOx did not show difference between both groups. Future research should aim at a microvascular dysfunction in RSI.

  5. Multivariate evaluation of brain function by measuring regional cerebral blood flow and event-related potentials

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Yoshihiko; Mochida, Masahiko; Shutara, Yoshikazu; Nakagawa, Kazumi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Nagata, Ken

    1998-07-01

    To measure the effect of events on human cognitive function, effects of odors by measurement regional cerebral blood flow (rCBF) and P300 were evaluated during the auditory odd-ball exercise. PET showed the increase in rCBF on the right hemisphere of the brain by coffee aroma. rCBF was measured by PET in 9 of right-handed healthy adults men, and P300 was by event-related potential (ERP) in each sex of 20 right-handed healthy adults. ERP showed the difference of the P300 amplitude between men and women, and showed the tendency, by odors except the lavender oil, that women had higher in the P300 amplitude than men. These results suggest the presence of effects on the cognitive function through emotional actions. Next, the relationship between rCBF and ERP were evaluated. The subjects were 9 of the right-handed healthy adults (average: 25.6{+-}3.4 years old). rCBF by PET and P300 amplitude by ERP were simultaneously recorded during the auditory odd-ball exercise using the tone-burst method (2 kHz of the low frequency aimed stimuli and 1 kHz of the high frequency non-aimed stimuli). The rCBF value was the highest at the transverse gyrus of Heschl and the lowest at the piriform cortex among 24 regions of interest (ROI) from both sides. The difference of P300 peak latent time among ROI was almost the same. The brain waves from Cz and Pz were similar and the average amplitude was highest at Pz. We found the high correlation in the right piriform cortex (Fz), and right (Fz, Cz) and left (Cz, Pz) transverse gyrus of Heschl between the P300 amplitude and rCBF. (K.H.)

  6. Simulation of Non-Newtonian Blood Flow by Lattice Boltzman Method

    Institute of Scientific and Technical Information of China (English)

    JI Yu-Pin; KANG Xiu-Ying; LIU Da-He

    2010-01-01

    @@ Blood flow under various conditions of vessel is simulated as a non-Newtonian fluid by the two-dimensional Lattice Boltzmann method,in which the Casson model is used to express the relationship between viscosity and shear rate of the blood.The flow field distributions at certain sites near the narrowing and bifurcation of the vessel explain the hemodynamic mechanism of the preclilection of the atherosclerotic lesions for these sites which are consistent with that found by medical studies.

  7. Examination of blood clobazam levels and several pupillary measures in humans.

    Science.gov (United States)

    Kotzan, J A; Needham, T E; Honigberg, I L; Vallner, J J; Stewart, J T; Brown, W J; Jun, H W

    1979-08-01

    The State-Trait Anxiety Inventory was administered to 15 subjects before initiation of the experiment. Three subgroups of five subjects were defined by computing the unweighted sum of the state and trait anxiety scores. A 40-mg dose of clobazam, a 1.5-benzodiazepine, was administered to each subject and repeated with two additional dosage forms following a 2-week washout period. Blood samples were withdrawn, and blood levels were determined by fluorometric analysis. Additionally, pupillary measures of critical flicker fusion, constriction, and dilation in response to a cognitive task were obtained at 0, 2, 4, and 6 hr. A repeated measures analysis of variance revealed that blood levels were, as expected, statistically different over time and dosage form. The pupillary constriction mirrored the blood levels in statistical patterns. The pupillary measure of cognition related to the anxiety state after the performance effects of the cognitive task were statistically removed. The results suggest that clobazam has less immediate human effect than does diazepam.

  8. In vivo measurement of hemodynamic information in stenosed rat blood vessels using X-ray PIV

    Science.gov (United States)

    Park, Hanwook; Park, Jun Hong; Lee, Sang Joon

    2016-11-01

    Measurements of the hemodynamic information of blood flows, especially wall shear stress (WSS), in animal models with circulatory vascular diseases (CVDs) are important to understand the pathological mechanism of CVDs. In this study, X-ray particle image velocimetry (PIV) with high spatial resolution was applied to obtain velocity field information in stenosed blood vessels with high WSS. 3D clips fabricated with a 3D printer were applied to the abdominal aorta of a rat cadaver to induce artificial stenosis in the real blood vessel of an animal model. The velocity and WSS information of blood flows in the stenosed vessel were obtained and compared at various stenosis severities. In vivo measurement was also conducted by fastening a stenotic clip on a live rat model through surgical intervention to reduce the flow rate to match the limited temporal resolution of the present X-ray PIV system. Further improvement of the temporal resolution of the system might be able to provide in vivo measurements of hemodynamic information from animal disease models under physiological conditions. The present results would be helpful for understanding the relation between hemodynamic characteristics and the pathological mechanism in animal CVD models.

  9. A Simple, Inexpensive and Safe Method for DNA Extraction of Frigid and Clotted Blood Samples

    Directory of Open Access Journals (Sweden)

    Nasrin Mohammadi

    2015-07-01

    Full Text Available Background: Extraction of blood genomicDNAis one of the main approaches for clinical and molecular biology studies. Although several methods have been developed for extraction of blood genomic DNA, most of these methods consume long time and use expensive chemicals such as proteinase K and toxic organic solvent such as phenol and chloroform. The objective of this study was to developed easy and safe method forDNAextraction from clotted and frozen whole blood. This method has many advantages: time reducing, using inexpensive materials, without phenol and chloroform, achieving of high molecular weight and good quality genomicDNA.Materials and Methods: DNA extraction was performed by two methods (new and phenol-chloroform method. Then quantity and quality parameters were evaluated by 1% agarose gel electrophoresis, Nano drop analysis and efficiency of Polymerase Chain Reaction (PCR.Results: Extracted DNA from 500μL of blood samples were 457.7ng/μl and 212ng/μL and their purity (OD260/OD280 were 1.8 and 1.81 for new recommended and phenol–chloroform methods respectively. The PCR results indicated that D16S539 and CSF1PO loci were amplified.Conclusion: These results shown that this method is simple, fast, safe and most economical.

  10. Determination of organic chemicals in human whole blood: Preliminary method development for volatile organics

    Energy Technology Data Exchange (ETDEWEB)

    Cramer, P.H.; Boggess, K.E.; Hosenfeld, J.M. (Midwest Research Institute, Kansas City, MO (USA)); Remmers, J.C.; Breen, J.J.; Robinson, P.E.; Stroup, C. (Environmental Protection Agency, Washington, DC (USA))

    1988-05-01

    Extensive commercial, industrial, and domestic use of volatile organic chemicals, virtually assures that the general population will be exposed to some level of this class of chemicals. Because blood interacts with the respiratory system and is a major component of the body, it is likely that the analysis of blood will show exposure to volatile organics. Monitoring of the blood in conjunction with monitoring of xenobiotic levels in urine and adipose tissue is an effective way to assess the total body burden resulting from exposure to a chemical. This article introduces a method for the detection and confirmation of selected volatile organics at parts-per-trillion (ppt) levels in whole human blood. Intended for routine use, the method consists of a dynamic headspace purge of water-diluted blood where a carrier gas sweeps the surface of the sample and removes a quantifiable amount of the volatile organics from the blood and into an adsorbent trap. The organics are thermally desorbed from the adsorbent trap and onto the analytical column in a gas-chromatographic/mass-spectrometric (GC/MS) system where limited mass-scan data are taken for qualitative and quantitative identification. Method validation results and limited population-survey results are also presented here.

  11. Unilateral kidney blood flow measurement using the 81Rb/81mKr ratio.

    NARCIS (Netherlands)

    van Herk, G.; de Zeeuw, D.

    1978-01-01

    A new method has been developed for the continuous quantification of kidney blood flow, utilizing the unique physical and biological properties of the radioactive tracer couple: rubidium-81/krypton-81m. After intravenous injection, 81Rb concentrates primarily in the kidneys, where it continuously ge

  12. Determination of organic chemicals in human whole blood: preliminary method development for volatile organics

    Energy Technology Data Exchange (ETDEWEB)

    Cramer, P.H.; Boggess, K.E.; Hosenfeld, J.M.; Remmers, J.C.; Breen, J.J.; Robinson, P.E.; Stroup, C.

    1988-04-01

    This article introduces a method for the detection and confirmation of selected volatile organics at parts-per-trillion (ppt) levels in whole human blood. Intended for routine use, the method consists of a dynamic headspace purge of water-diluted blood where a carrier gas sweeps the surface of the sample and removes a quantifiable amount of the volatile organics from the blood and into an adsorbent trap. The organics are thermally desorbed form the adsorbent trap and onto the analytical column in a gas-chromatographic/mass-spectrometric (GC/MS) system where limited mass-scan data are taken for qualitative and quantitative identification. The method can be employed for compounds normally defined as volatile organics, such as those on the EPA priority-pollutant-volatiles list. Method validation results and limited population-survey results are also presented here.

  13. Dual beam Doppler FD-OCT system with integrated Dynamic Vessel Analyzer and rotatable beams to measure total retinal blood flow

    Science.gov (United States)

    Doblhoff-Dier, Veronika; Werkmeister, René M.; Gröschl, Martin; Schmetterer, Leopold

    2014-03-01

    We present a method capable of measuring the total retinal blood flow in arteries and veins based on dual beam Fourierdomain Doppler optical coherence tomography (OCT) in combination with a fundus camera based Dynamic Vessel Analyzer. Incorporating a Dynamic vessel analyzer into the system not only gives a live image of the fundus - it also allows determining the vessels' diameter precisely during the OCT measurement, which is necessary for the determination of the blood flow. While dual beam systems with fixed detection plane allow only vessels with certain orientations to be measured, the detection plane of our system can be rotated by 90°. This ensures that the blood's velocity can be measured in all vessels around the optic nerve head. The results of the total blood flow measurements are in the same range as previously published data. Additionally, the high degree of conformity between the measured venous and arterial flow corroborated the system's validity. For larger vessels, the logarithmic values of vessel diameter and blood flow were found to be related linearly with a regression coefficient of around 3, which is in accordance with Murray's law. For smaller vessels (diameter below 60 μm), the values diverge from the linear dependence. The high sensitivity and the good agreement with published data suggest a high potential for examining the retinal blood flow in patients with ocular diseases.

  14. A methodical approach to performance measurement experiments : measure and measurement specification

    NARCIS (Netherlands)

    Hoeksema, F.W.; Veen, van der J.T.; Beijnum, van B.J.F.

    1997-01-01

    This report describes a methodical approach to performance measurement experiments. This approach gives a blueprint for the whole trajectory from the notion of performance measures and how to define them via planning, instrumentation and execution of the experiments to interpretation of the results.

  15. Characteristic absorption peak of the human blood measured with differential photoacoustic spectroscopy

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    A new highly sensitive spectroscopy technique- differential photoacoustic spectroscopy (PAS) is presented in this paper. The blood samples from 3 healthy persons, patients with leukemia, patients with pregnancy-induced hypertension (PIH), and 40 patients with nasopharyngeal carcinoma were measured by the PAS technique. The normalized, the first order, and the second order differential photoacoustic spectroscopy of the blood were gained. The results show that (ⅰ) weak absorption peaks or shoulder peaks, which could not be found using conventional photoacoustic spectroscopy, were determined by the first order and the second order differential photoacoustic spectroscopy which significantly improve the sensitivity of detection; and (ii) that two characteristic absorption peaks were found at the wavelength of 637 and 664 nm in all persons' blood samples by the differential photoacoustic spectroscopy technique. This experiment concludes that the differential photoacoustic spectroscopy technique is superior to the conventional photoacoustic spectroscopy technique in detecting photoacoustic spectroscopy of biological samples.

  16. In Vivo μPIV Measurements of Blood Flow in Small Vessels of a Rat Model.

    Science.gov (United States)

    Wei, Timothy; Conner, Nadine; Russell, John; Legac, Paul

    2007-11-01

    Ongoing research at the University of Wisconsin Medical School is addressing the effects of perfusion of glottal tissue on voice production. Building on the approach developed by Gharib's group at CalTech for embryonic zebra fish, we have modified μPIV to measure flow in capillaries and small blood vessels in a live rat model. In lieu of seeding particles, the DPIV correlation algorithm tracks the motion of red blood cells moving through these vessels. The methodology will be presented along with a video sequence showing measurements made from muscle tissue laid nominally flat on a microscope stage. Challenges of measurements in three-dimensional geometries, i.e. the throat, will be discussed.

  17. Label-free characterization of white blood cells by measuring 3D refractive index maps

    CERN Document Server

    Yoon, Jonghee; Park, HyunJoo; Choi, Chulhee; Jang, Seongsoo; Park, YongKeun

    2015-01-01

    The characterization of white blood cells (WBCs) is crucial for blood analyses and disease diagnoses. However, current standard techniques rely on cell labeling, a process which imposes significant limitations. Here we present three-dimensional (3D) optical measurements and the label-free characterization of mouse WBCs using optical diffraction tomography. 3D refractive index (RI) tomograms of individual WBCs are constructed from multiple two-dimensional quantitative phase images of samples illuminated at various angles of incidence. Measurements of the 3D RI tomogram of WBCs enable the separation of heterogeneous populations of WBCs using quantitative morphological and biochemical information. Time-lapse tomographic measurements also provide the 3D trajectory of micrometer-sized beads ingested by WBCs. These results demonstrate that optical diffraction tomography can be a useful and versatile tool for the study of WBCs.

  18. A methodical approach to performance measurement experiments : measure and measurement specification

    OpenAIRE

    Hoeksema, F.W.; Veen,, A. m.; Beijnum, van, B.J.F.

    1997-01-01

    This report describes a methodical approach to performance measurement experiments. This approach gives a blueprint for the whole trajectory from the notion of performance measures and how to define them via planning, instrumentation and execution of the experiments to interpretation of the results. The first stage of the approach, Measurement Initialisation, has been worked out completely. It is shown that a well-defined system description allows a procedural approach to defining performance...

  19. Association between DNA Methylation in Whole Blood and Measures of Glucose Metabolism: KORA F4 Study.

    Directory of Open Access Journals (Sweden)

    Jennifer Kriebel

    Full Text Available Epigenetic regulation has been postulated to affect glucose metabolism, insulin sensitivity and the risk of type 2 diabetes. Therefore, we performed an epigenome-wide association study for measures of glucose metabolism in whole blood samples of the population-based Cooperative Health Research in the Region of Augsburg F4 study using the Illumina HumanMethylation 450 BeadChip. We identified a total of 31 CpG sites where methylation level was associated with measures of glucose metabolism after adjustment for age, sex, smoking, and estimated white blood cell proportions and correction for multiple testing using the Benjamini-Hochberg (B-H method (four for fasting glucose, seven for fasting insulin, 25 for homeostasis model assessment-insulin resistance [HOMA-IR]; B-H-adjusted p-values between 9.2x10(-5 and 0.047. In addition, DNA methylation at cg06500161 (annotated to ABCG1 was associated with all the aforementioned phenotypes and 2-hour glucose (B-H-adjusted p-values between 9.2x10(-5 and 3.0x10(-3. Methylation status of additional three CpG sites showed an association with fasting insulin only after additional adjustment for body mass index (BMI (B-H-adjusted p-values = 0.047. Overall, effect strengths were reduced by around 30% after additional adjustment for BMI, suggesting that this variable has an influence on the investigated phenotypes. Furthermore, we found significant associations between methylation status of 21 of the aforementioned CpG sites and 2-hour insulin in a subset of samples with seven significant associations persisting after additional adjustment for BMI. In a subset of 533 participants, methylation of the CpG site cg06500161 (ABCG1 was inversely associated with ABCG1 gene expression (B-H-adjusted p-value = 1.5x10(-9. Additionally, we observed an enrichment of the top 1,000 CpG sites for diabetes-related canonical pathways using Ingenuity Pathway Analysis. In conclusion, our study indicates that DNA methylation and

  20. Association between DNA Methylation in Whole Blood and Measures of Glucose Metabolism: KORA F4 Study.

    Science.gov (United States)

    Kriebel, Jennifer; Herder, Christian; Rathmann, Wolfgang; Wahl, Simone; Kunze, Sonja; Molnos, Sophie; Volkova, Nadezda; Schramm, Katharina; Carstensen-Kirberg, Maren; Waldenberger, Melanie; Gieger, Christian; Peters, Annette; Illig, Thomas; Prokisch, Holger; Roden, Michael; Grallert, Harald

    2016-01-01

    Epigenetic regulation has been postulated to affect glucose metabolism, insulin sensitivity and the risk of type 2 diabetes. Therefore, we performed an epigenome-wide association study for measures of glucose metabolism in whole blood samples of the population-based Cooperative Health Research in the Region of Augsburg F4 study using the Illumina HumanMethylation 450 BeadChip. We identified a total of 31 CpG sites where methylation level was associated with measures of glucose metabolism after adjustment for age, sex, smoking, and estimated white blood cell proportions and correction for multiple testing using the Benjamini-Hochberg (B-H) method (four for fasting glucose, seven for fasting insulin, 25 for homeostasis model assessment-insulin resistance [HOMA-IR]; B-H-adjusted p-values between 9.2x10(-5) and 0.047). In addition, DNA methylation at cg06500161 (annotated to ABCG1) was associated with all the aforementioned phenotypes and 2-hour glucose (B-H-adjusted p-values between 9.2x10(-5) and 3.0x10(-3)). Methylation status of additional three CpG sites showed an association with fasting insulin only after additional adjustment for body mass index (BMI) (B-H-adjusted p-values = 0.047). Overall, effect strengths were reduced by around 30% after additional adjustment for BMI, suggesting that this variable has an influence on the investigated phenotypes. Furthermore, we found significant associations between methylation status of 21 of the aforementioned CpG sites and 2-hour insulin in a subset of samples with seven significant associations persisting after additional adjustment for BMI. In a subset of 533 participants, methylation of the CpG site cg06500161 (ABCG1) was inversely associated with ABCG1 gene expression (B-H-adjusted p-value = 1.5x10(-9)). Additionally, we observed an enrichment of the top 1,000 CpG sites for diabetes-related canonical pathways using Ingenuity Pathway Analysis. In conclusion, our study indicates that DNA methylation and diabetes

  1. [The net analyte preprocessing combined with radial basis partial least squares regression applied in noninvasive measurement of blood glucose].

    Science.gov (United States)

    Li, Qing-Bo; Huang, Zheng-Wei

    2014-02-01

    In order to improve the prediction accuracy of quantitative analysis model in the near-infrared spectroscopy of blood glucose, this paper, by combining net analyte preprocessing (NAP) algorithm and radial basis functions partial least squares (RBFPLS) regression, builds a nonlinear model building method which is suitable for glucose measurement of human, named as NAP-RBFPLS. First, NAP is used to pre-process the near-infrared spectroscopy of blood glucose, in order to effectively extract the information which only relates to glucose signal from the original near-infrared spectra, so that it could effectively weaken the occasional correlation problems of the glucose changes and the interference factors which are caused by the absorption of water, albumin, hemoglobin, fat and other components of the blood in human body, the change of temperature of human body, the drift of measuring instruments, the changes of measuring environment, and the changes of measuring conditions; and then a nonlinear quantitative analysis model is built with the near-infrared spectroscopy data after NAP, in order to solve the nonlinear relationship between glucose concentrations and near-infrared spectroscopy which is caused by body strong scattering. In this paper, the new method is compared with other three quantitative analysis models building on partial least squares (PLS), net analyte preprocessing partial least squares (NAP-PLS) and RBFPLS respectively. At last, the experimental results show that the nonlinear calibration model, developed by combining NAP algorithm and RBFPLS regression, which was put forward in this paper, greatly improves the prediction accuracy of prediction sets, and what has been proved in this paper is that the nonlinear model building method will produce practical applications for the research of non-invasive detection techniques on human glucose concentrations.

  2. Measurement and treatment of elevated blood pressure in the pediatric patient with chronic kidney disease.

    Science.gov (United States)

    Swinford, Rita D; Portman, Ronald J

    2004-04-01

    Hypertension, as in adults, is a frequent complication found in children with chronic kidney disease (CKD). Indeed, hypertension has now become one of the most prevalent chronic diseases of childhood. The most recent data available (2003) indicate that at least 38% of children with CKD in the United States are receiving antihypertensive therapy. Only recently has it been shown in children that hypertension, traditionally considered a marker for disease severity in children, is additionally a significant and independent risk factor for accelerated deterioration of kidney function and progression of CKD and a significant risk factor for cardiovascular disease. The following review outlines the differences and similarities of childhood versus adult hypertension with respect to measurement, diagnosis, treatment, and consequence in CKD. The definition of hypertension changes continually as a child grows with or without CKD. Despite numerous guidelines, the diagnosis of childhood hypertension continues to be based on epidemiologic data rather than evidence. For children, the current definition includes 2 categories: high normal, which is blood pressure (BP) between the 90th and 95th percentile, and hypertensive, which is BP above the 95th percentile. The evaluation of all hypertensive children should include a complete assessment of end-organ damage, including eyes, cardiovascular system (including blood vessels), kidneys, and nervous system. For children with CKD and end-stage renal disease (ESRD), a high percentage have left ventricular hypertrophy (LVH). The finding of end-organ damage or comorbidity (CKD, diabetes) in any child is an absolute indication for immediate pharmacologic therapy, whereas the presence of hypertension above the 95th percentile in children without CKD warrants initial intervention such as life style modification. The guidelines for measurement of BP in children with CKD are similar to those in children without CKD and include casual BP

  3. Rethinking traditional methods for measuring intellectual capital.

    Science.gov (United States)

    Corso, John A

    2007-01-01

    Historically, approaches to measuring intellectual capital have included both conventional accounting-based measures, such as variants of the market-to-book ratio, and more progressive measures, such as the measurement of intangible assets found in approaches such as the Balanced Scorecard and Human Resource Accounting. As greater emphasis is placed on intellectual capital and its various aspects in the continually growing service and knowledge economy, the use of assessment instruments to inventory the alignment, balance, and variety of intellectual capacities and metrics that assess the effectiveness of succession planning may represent new directions in which organizations can head in the measurement of this important construct.

  4. Development of a diagnostic sensor for measuring blood cell concentrations during haemoconcentration

    Science.gov (United States)

    Robertson, Craig A.; Gourlay, Terence

    2016-01-01

    Background: HemoSep® is a commercial ultrafiltration and haemoconcentration device for the concentration of residual bypass blood following surgery. This technology is capable of reducing blood loss in cardiac and other types of “clean site” procedures, including paediatric surgery. Clinical feedback suggested that the device would be enhanced by including a sensor technology capable of discerning the concentration level of the processed blood product. We sought to develop a novel sensor that can, using light absorption, give an accurate estimate of packed cell volume (PCV). Materials and methods: A sensor-housing unit was 3D printed and the factors influencing the sensor’s effectiveness – supply voltage, sensitivity and emitter intensity - were optimised. We developed a smart system, using comparator circuitry capable of visually informing the user when adequate PCV levels (⩾35%) are attained by HemoSep® blood processing, which ultimately indicates that the blood is ready for autotransfusion. Results: Our data demonstrated that the device was capable of identifying blood concentration at and beyond the 35% PCV level. The device was found to be 100% accurate at identifying concentration levels of 35% from a starting level of 20%. Discussion: The sensory capability was integrated into HemoSep’s® current device and is designed to enhance the user’s clinical experience and to optimise the benefits of HemoSep® therapy. The present study focused on laboratory studies using bovine blood. Further studies are now planned in the clinical setting to confirm the efficacy of the device. PMID:27591743

  5. In-line acid concentration measuring method and measuring probe

    Energy Technology Data Exchange (ETDEWEB)

    Kuno, Takehiko; Kurosawa, Akira; Sato, Soichi

    1998-09-11

    A measuring probe comprising an electrode for voltammetry, a supersonic sensor and a conductivity measuring electrode formed integrally is immersed in a solution for a reprocessing step. A relationship between an acid concentration of the solution having U and Pu concentrations as variable parameters and a propagation speed of supersonic waves in the solution is previously determined, and a propagation speed of the supersonic waves in the solution for the reprocessing step is measured. An acid concentration is determined by using U and Pu concentrations of the solution of the reprocessing step measured in-line by using voltammetry based on the relationship between the acid concentration at that U and Pu concentrations and the supersonic propagation speed. In addition, conductivity of the liquid for the step is measured by a solution conductivity meter, and an acid concentration is measured in-line based on the relationship between the acid concentration and the conductivity in the same manner. With such procedures, a reprocessing plant can be operated rapidly and smoothly, as well as the analysis operation can be simplified. (T.M.)

  6. Blood species identification using Near-Infrared diffuse transmitted spectra and PLS-DA method

    Science.gov (United States)

    Zhang, Linna; Zhang, Shengzhao; Sun, Meixiu; Wang, Zhennan; Li, Hongxiao; Li, Yingxin; Li, Gang; Lin, Ling

    2016-05-01

    Blood species identification is of great significance for blood supervision and wildlife investigations. The current methods used to identify the blood species are destructive. Near-Infrared spectroscopy method is known for its non-invasive properties. In this research, we combined Near-Infrared diffuse transmitted spectra and Partial Least Square Discrimination Analysis (PLS-DA) to identify three blood species, including macaque, human and mouse. Blind test and external test were used to assess the PLS-DA model. The model performed 100% accuracy in its identification between three blood species. This approach does not require a specific knowledge of biochemical features for each individual class but relies on a spectroscopic statistical differentiation of the whole components. This is the first time to demonstrate Near-Infrared diffuse transmitted spectra have the ability to identify the species of origin of blood samples. The results also support a good potential of absorption and scattering spectroscopy for species identification in practical applications for real-time detection.

  7. The impact of different blood sampling methods on laboratory rats under different types of anaesthesia

    DEFF Research Database (Denmark)

    Toft, Martin Fitzner; Petersen, Mikke Haxø; Dragsted, Nils

    2006-01-01

    for rats sampled from the tail vein, which showed fluctuations in body temperature in excess of 30 h after sampling. Increases in heart rate and blood pressure within the first hours after sampling indicated that periorbital puncture was the method that had the largest acute impact on the rats......Rats with implanted telemetry transponders were blood sampled by jugular puncture, periorbital puncture or tail vein puncture, or sampled by jugular puncture in carbon dioxide (CO?), isoflurane or without anaesthesia in a crossover design. Heart rate, blood pressure and body temperature were...... registered for three days after sampling. Initially blood pressure increased, but shortly after sampling it decreased, which led to increased heart rate. Sampling induced rapid fluctuations in body temperature, and an increase in body temperature. Generally, rats recovered from sampling within 2-3 h, except...

  8. Minimally invasive blood sampling method for genetic studies on Gopherus tortoises

    Directory of Open Access Journals (Sweden)

    García–Feria, L. M.

    2015-04-01

    Full Text Available Obtaining good quality tissue samples is the first hurdle in any molecular study. This is especially true for studies involving management and conservation of wild fauna. In the case of tortoises, the most common sources of DNA are blood samples. However, only a minimal amount of blood is required for PCR assays. Samples are obtained mainly from the brachial and jugular vein after restraining the animal chemically, or from conscious individuals by severe handling methods and clamping. Herein, we present a minimally invasive technique that has proven effective for extracting small quantities of blood, suitable for genetic analyses. Furthermore, the samples obtained yielded better DNA amplification than other cell sources, such as cloacal epithelium cells. After two years of use on wild tortoises, this technique has shown to be harmless. We suggest that sampling a small amount of blood could also be useful for other types of analyses, such as physiologic and medical monitoring.

  9. Device and method for automated separation of a sample of whole blood into aliquots

    Science.gov (United States)

    Burtis, Carl A.; Johnson, Wayne F.

    1989-01-01

    A device and a method for automated processing and separation of an unmeasured sample of whole blood into multiple aliquots of plasma. Capillaries are radially oriented on a rotor, with the rotor defining a sample chamber, transfer channels, overflow chamber, overflow channel, vent channel, cell chambers, and processing chambers. A sample of whole blood is placed in the sample chamber, and when the rotor is rotated, the blood moves outward through the transfer channels to the processing chambers where the blood is centrifugally separated into a solid cellular component and a liquid plasma component. When the rotor speed is decreased, the plasma component backfills the capillaries resulting in uniform aliquots of plasma which may be used for subsequent analytical procedures.

  10. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device.

  11. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  12. Reference data for distal blood pressure in healthy elderly and middle-aged individuals measured with the strain gauge technique. Part II: Distal blood pressure after exercise

    DEFF Research Database (Denmark)

    Arveschoug, Anne Kirstine; Vammen, Birthe; Yoshinaka, Emmy

    2008-01-01

    Objective. Distal blood pressure (DBP) determination after an exercise test is used on suspicion of arterial peripheral vascular disease (apvd). In our department. the average age of these patients is about 60 years. The usual reference values for pressures after exercise were based on data...... collected in the early 1970s from healthy individuals in the age range 21-26 years. Our aims were to collect new reference data for DBP at ankle level after exercise based on older populations, and to compare between reference data for different age groups to find out whether the normal values are dependent...... on age. Material and methods. DBP after exercise was measured using the strain-gauge technique on individuals in two groups: group I comprising 25 healthy persons aged between 61 and 82 years, and group II 14 healthy persons aged between 45 and 58 years. Strict rules of inclusion were followed. Results...

  13. Evaluation of three rapid diagnostic methods for direct identification of microorganisms in positive blood cultures.

    Science.gov (United States)

    Martinez, Raquel M; Bauerle, Elizabeth R; Fang, Ferric C; Butler-Wu, Susan M

    2014-07-01

    The identification of organisms from positive blood cultures generally takes several days. However, recently developed rapid diagnostic methods offer the potential for organism identification within only a few hours of blood culture positivity. In this study, we evaluated the performance of three commercial methods to rapidly identify organisms directly from positive blood cultures: QuickFISH (AdvanDx, Wolburn, MA), Verigene Gram-Positive Blood Culture (BC-GP; Nanosphere, Northbrook, IL), and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) with Sepsityper processing (Bruker Daltonics, Billerica, MA). A total of 159 blood cultures (VersaTREK Trek Diagnostic Systems, Cleveland, OH) positive for Gram-positive and Gram-negative bacteria as well as yeast were analyzed with QuickFISH and MALDI-TOF MS. In all, 102 blood cultures were analyzed using the BC-GP assay. For monomicrobial cultures, we observed 98.0% concordance with routine methods for both QuickFISH (143/146) and the BC-GP assay (93/95). MALDI-TOF MS demonstrated 80.1% (117/146) and 87.7% (128/146) concordance with routine methods to the genus and species levels, respectively. None of the methods tested were capable of consistently identifying polymicrobial cultures in their entirety or reliably differentiating Streptococcus pneumoniae from viridans streptococci. Nevertheless, the methods evaluated in this study are convenient and accurate for the most commonly encountered pathogens and have the potential to dramatically reduce turnaround time for the provision of results to the treating physician.

  14. Comparison of Real-time PCR method and blood culture in diagnosis of septicemia

    Directory of Open Access Journals (Sweden)

    Ali Gholami

    2016-02-01

    Full Text Available Background: Bloodstream infections (BSI have a high incidence and high mortality in the worldwide. The mortality rate is variable between 20-70%. Therefore, early and timely detection of BSI agent in clinical laboratories is necessary. The aim of this study was to determine an efficient diagnostic tool to septicemia in accompany of blood culture method by Real-time PCR (using panbacterial 23S rRNA gene. Methods: This cross-sectional study was conducted in two analytical and clinical stages in Hamadan University of Medical Sciences, Iran, from October 2014 to June 2015. In analytical stage, sensitivity (by serial dilution from 104 to 1 CFU/ml and specificity of the primer were evaluated with the Staphylococcus aureus (as Gram positive indicator bacteria and Escherichia coli (as Gram-negative indicator bacteria, human genome (from Hella cell culture, Candida albicans yeast and Aspergillus fumigatus fungus. In clinical stage, 121 blood samples were collected from patients suspected to sepsis in intensive care unit (ICU from Hamadan University Hospitals. Finally, the results of Real-time PCR and blood culture methods were compared. Results: The Real-time PCR showed a sensitivity ranging from 2 to 10 target copies per reaction to the whole blood for Escherichia coli and Staphylococcus aureus respectively. The specificity of this method was evaluated and no false positive amplification was identified. 57.85% (70 cases of the samples were positive by Real-time PCR and 13.22% (16 cases of the samples were positive by blood culture. However, none of the cases that were positive by blood culture were negative in Real-time PCR. As well as, 44.62% (54 cases of cases were positive by Real-time PCR but blood culture showed no bacteria in the samples, and 42.15% (51 cases were negative by both methods. Correlation or agreement of Kappa was 0.20, that indicating poor agreement between the two methods. Conclusion: Real-time PCR is more sensitive than blood

  15. PERT: a method for expression deconvolution of human blood samples from varied microenvironmental and developmental conditions.

    Directory of Open Access Journals (Sweden)

    Wenlian Qiao

    Full Text Available The cellular composition of heterogeneous samples can be predicted using an expression deconvolution algorithm to decompose their gene expression profiles based on pre-defined, reference gene expression profiles of the constituent populations in these samples. However, the expression profiles of the actual constituent populations are often perturbed from those of the reference profiles due to gene expression changes in cells associated with microenvironmental or developmental effects. Existing deconvolution algorithms do not account for these changes and give incorrect results when benchmarked against those measured by well-established flow cytometry, even after batch correction was applied. We introduce PERT, a new probabilistic expression deconvolution method that detects and accounts for a shared, multiplicative perturbation in the reference profiles when performing expression deconvolution. We applied PERT and three other state-of-the-art expression deconvolution methods to predict cell frequencies within heterogeneous human blood samples that were collected under several conditions (uncultured mono-nucleated and lineage-depleted cells, and culture-derived lineage-depleted cells. Only PERT's predicted proportions of the constituent populations matched those assigned by flow cytometry. Genes associated with cell cycle processes were highly enriched among those with the largest predicted expression changes between the cultured and uncultured conditions. We anticipate that PERT will be widely applicable to expression deconvolution strategies that use profiles from reference populations that vary from the corresponding constituent populations in cellular state but not cellular phenotypic identity.

  16. PERT: a method for expression deconvolution of human blood samples from varied microenvironmental and developmental conditions.

    Science.gov (United States)

    Qiao, Wenlian; Quon, Gerald; Csaszar, Elizabeth; Yu, Mei; Morris, Quaid; Zandstra, Peter W

    2012-01-01

    The cellular composition of heterogeneous samples can be predicted using an expression deconvolution algorithm to decompose their gene expression profiles based on pre-defined, reference gene expression profiles of the constituent populations in these samples. However, the expression profiles of the actual constituent populations are often perturbed from those of the reference profiles due to gene expression changes in cells associated with microenvironmental or developmental effects. Existing deconvolution algorithms do not account for these changes and give incorrect results when benchmarked against those measured by well-established flow cytometry, even after batch correction was applied. We introduce PERT, a new probabilistic expression deconvolution method that detects and accounts for a shared, multiplicative perturbation in the reference profiles when performing expression deconvolution. We applied PERT and three other state-of-the-art expression deconvolution methods to predict cell frequencies within heterogeneous human blood samples that were collected under several conditions (uncultured mono-nucleated and lineage-depleted cells, and culture-derived lineage-depleted cells). Only PERT's predicted proportions of the constituent populations matched those assigned by flow cytometry. Genes associated with cell cycle processes were highly enriched among those with the largest predicted expression changes between the cultured and uncultured conditions. We anticipate that PERT will be widely applicable to expression deconvolution strategies that use profiles from reference populations that vary from the corresponding constituent populations in cellular state but not cellular phenotypic identity.

  17. Spectrophotometric determination of total proteins in blood plasma: a comparative study among dye-binding methods

    Directory of Open Access Journals (Sweden)

    Dimas Augusto Morozin Zaia

    2005-05-01

    Full Text Available A comparative study between the biuret method (standard method for total proteins and spectrophotometric methods using dyes (Bradford, 3',3",5',5"-tetrabromophenolphthalein ethyl ester-TBPEE, and erythrosin-B was carried out for the determination of total proteins in blood plasma from rats. Bradford method showed the highest sensitivity for proteins and biuret method showed the lowest. For all the methods, the absorbance for different proteins (BSA, casein, and egg albumin was measured and Bradford method showed the lowest variation of absorbance. The concentration of total protein obtained by using Bradford method was not statistically different (p>0.05 from concentration of total protein obtained by the biuret method. But in regard to erythrosin-B and TBPEE methods the concentrations of total protein were statistically different (pA determinação de proteínas totais em plasma sangüíneo é importante em diversas áreas de pesquisa. Um estudo comparativo entre o método de biureto (método padrão para proteínas totais e diversos métodos que utilizam corantes (Bradford, tetrabromofenolftaleína etil éster-TBPEE, e eritrosina-B foi realizado para a determinação de proteínas totais em plasma sangüíneo de ratos. O método de Bradford mostrou a maior sensibilidade para proteínas e o de biureto a menor. Para todos os métodos, as absorbâncias para diferentes proteínas (BSA, caseína, e ovoalbumina foram medidas e o método de Bradford mostrou a menor variação da absorbância. Utilizando o método de Bradford a concentração de proteínas totais obtida não foi estatisticamente diferente (p>0.05 daquela obtida pelo método do biureto. Porém, para os métodos da eritrosina-B e TBPEE as concentrações de proteínas totais foram estatisticamente diferentes (p<0.05 da obtida pelo método de biureto. Portanto o método de Bradford pode ser utilizado no lugar do método de biureto para a determinação de proteínas totais em plasma sangüíneo.

  18. Measurement of Chloroform in Swimming Pools' Waters and Swimmers’ Blood

    Directory of Open Access Journals (Sweden)

    S Shegefti

    2009-12-01

    Full Text Available "nBackground: A new microextraction method named dispersive liquid-liquid microextraction (DLLME for determination of chloroform in pool water and blood of swimmers after swimming is described."nMethods: This method was performed based on coupling dispersive liquid-liquid microextraction (DLLME with gas chromatog­raphy-mass spectrometry (GC-MS. Methanol and trichloroethylenes were used as the disperser solvent and the extrac­tion solvents, respectively. The volumes of these solvents were optimized for pool water by central composite design. The study involved three indoor swimming pools and nine swimmers."nResults: Chloroform concentration of pool water was 118-135 µg L-1 and of blood ranged from 1.26 to 1.66 µg L-1."nConclusion: Indoor swimming pools are closed environments presenting detectable levels of trihalomethanes (THMs. Chloro­form (CHCl3 is the most represented THMs. Therefore, the presence of CHCl3 may be considered representative of the THMs. The new method DLLME was applied for determination of CHCl3 in pool water and blood of swimmers after swim­ming inside the indoor swimming pool. The method was optimized by experimental design. Chloroform concentra­tions in the specified pool waters were 135, 124, 118 µg L-1.

  19. Comparison of cerebral blood flow measurement with [15O]-water positron emission tomography and arterial spin labeling magnetic resonance imaging: A systematic review.

    Science.gov (United States)

    Fan, Audrey P; Jahanian, Hesamoddin; Holdsworth, Samantha J; Zaharchuk, Greg

    2016-05-01

    Noninvasive imaging of cerebral blood flow provides critical information to understand normal brain physiology as well as to identify and manage patients with neurological disorders. To date, the reference standard for cerebral blood flow measurements is considered to be positron emission tomography using injection of the [(15)O]-water radiotracer. Although [(15)O]-water has been used to study brain perfusion under normal and pathological conditions, it is not widely used in clinical settings due to the need for an on-site cyclotron, the invasive nature of arterial blood sampling, and experimental complexity. As an alternative, arterial spin labeling is a promising magnetic resonance imaging technique that magnetically labels arterial blood as it flows into the brain to map cerebral blood flow. As arterial spin labeling becomes more widely adopted in research and clinical settings, efforts have sought to standardize the method and validate its cerebral blood flow values against positron emission tomography-based cerebral blood flow measurements. The purpose of this work is to critically review studies that performed both [(15)O]-water positron emission tomography and arterial spin labeling to measure brain perfusion, with the aim of better understanding the accuracy and reproducibility of arterial spin labeling relative to the positron emission tomography reference standard.

  20. Validation of a continuous penile blood-flow measurement by pulse-volume-plethysmography.

    Science.gov (United States)

    Lavoisier, P; Barbe, R; Gally, M

    2002-04-01

    Today, in the assessment of cavernous artery blood-flow, the most commonly used technique is Doppler ultrasound velocimetry (continuous, pulsed, color-coded or power), which is often considered as the gold standard. Plethysmographic techniques and radioactive tracers have been widely used for the assessment of global penis flow variations but are not adequate for continuous blood-flow measurement. A new pulse-volume plethysmographic (PVP) device using a water-filled penile cuff was employed to assess continuous blood-flow measurement in the penis. Simultaneously Doppler velocity was recorded and served as a gold standard. A penile water-cuff is connected through a pressure tube to a three-way tap. The pulse-volume changes in the penile water-cuff are measured by means of a latex membrane placed over one of the three-way taps. The displacements of the latex are recorded by a photoplethysmograph. The third tap is connected to a 5 l perfusion bag placed 30 cm above the penis so as to maintain constant pressure in the whole device whatever the penis volume. Twenty-four volunteers were tested. The Doppler velocity signal and pulse volume of cavernous arteries were measured simultaneously after PGE1 intra-cavernous injection. Blood-flow variations were induced by increasing penis artery compression with a second penile water-cuff used as a tourniquet fitted onto the penis root, and the pressure of which could be modified by a water-filled syringe. The amplitude of the plethysmographic pulse-volume signal and the area under the Doppler velocity signal were correlated. The inter-patient (n=24) correlation ranged from 0.455 to 0.904, with a mean correlation of 0.704 and P<0.0001. PVP measurement by a water-filled cuff was validated by ultrasound velocimetry. This new continuous, non-invasive and easy-to-use technique enables physiological and physiopathological flow-measurement during sleep, under visual sexual stimulation (VSS), or following artificial erection

  1. Simulation of Blood Flow at Vessel Bifurcation by Lattice Boltzmann Method

    Science.gov (United States)

    Kang, Xiu-Ying; Liu, Da-He; Zhou, Jing; Jin, Yong-Juan

    2005-11-01

    The application of the lattice Boltzmann method to the large vessel bifurcation blood flow is investigated in a wide range of Reynolds numbers. The velocity, shear stress and pressure distributions at the bifurcation are presented in detail. The flow separation zones revealed with increase of Reynolds number are located in the areas of the daughter branches distal to the outer corners of the bifurcation where some deposition of particular blood components might occur to form arteriosclerosis. The results also demonstrate that the lattice Boltzmann method is adaptive to simulating the flow in larger vessels under a high Reynolds number.

  2. A Digital Method for the Detection of Blood Flow Direction in Ultrasonic Doppler Systems

    Directory of Open Access Journals (Sweden)

    P. Acevedo–Contla.

    2010-01-01

    Full Text Available Doppler ultrasound systems are widely used to study blood flow and diagnosis of vascular diseases. An important characteristic of these systems is the ability to detect the direction of the blood flow. Most Doppler ultrasound systems apply a quadrature demodulation technique on the ultrasonic transducer output signal. Therefore additional treatment is necessary to separate forward and reverse flow signals. This work presents a digital method to convert signals in quadrature into directional signals using a Fast Fourier Transform (FFT approach. Validation of the method has been achieved using simulated Doppler ultrasound signals.

  3. Nocturnal blood pressure and intraocular pressure measurement in glaucoma patients and healthy controls.

    Science.gov (United States)

    Follmann, P; Palotás, C; Süveges, I; Petrovits, A

    Daytime and nocturnal intraocular pressure (IOP) values and systemic blood pressure (BP) values were compared in 60 non-glaucomatous controls, 54 glaucoma patients with normal visual field, and 46 glaucoma patients with visual field loss. The daytime IOP was measured with a Goldmann applanation tonometer and the nocturnal IOP with a Bio-Rad-Tono-Pen 2. The BP was measured with either a mercury manometer or with a Meditech ABPM-02 Ambulatory Blood Pressure Monitor, which took BP readings at 60 minute intervals. A tendency towards increasing IOP and decreasing BP was detected in the non-glaucomatous controls, within normal limits, and pathological changes of IOP and BP were observed with a significantly high occurrence (5% > P > 2%; Pearson's chi 2-test) in the glaucoma group with visual field loss.

  4. Development of fiber optic laser Doppler velocimeter for measurement of local blood velocity

    Science.gov (United States)

    Ohba, Kenkich; Fujiwara, Noboru

    1993-08-01

    In order to measure the local velocity field in opaque fluid flows like blood flow, a new laser Doppler velocimeter having a pickup consisting of a small distributed index lens attached to the tips of two fibers which are joined side by side in parallel has been newly developed. The distributed index lens is the shape of a truncated cone. The flow field around this sensor has been measured very precisely by means of an ordinary LDV. The effect of turbidity of fluid on the quality of the laser Doppler signal from this sensor has been examined by experiments. As a result, it has been shown that this LDV sensor has a high signal-to-noise ratio, and that the disturbance against flow by the sensor is very small, and it is very promising as a velocity sensor for opaque or semi-opaque fluid flow like blood flow.

  5. A rapid, non enzymatic method for genomic DNA extraction from whole blood and mammalian tissues

    Directory of Open Access Journals (Sweden)

    Adnan F. N Al-azawy

    2011-05-01

    Full Text Available Although several methods have been exist for DNA extraction from blood or animal tissues samples, traditionally most of these methods consume long time and using expensive chemicals such as proteinase K or toxic organic solvent such as phenol. On the other hand, there is no rapid, simple one method for the extraction of genomic DNA from blood and animal tissues samples in the same time. Since the objective of this study was to development easy modified method for DNA extraction from difference mammalian tissues such as fresh or frozen whole blood, kidney, liver, heart, muscles. The description method have many advantages, reducing the time, using inexpensive materials, no phenol, in addition to small amount of mammalian tissue is required (100-200 mg and 2 ml from whole blood. Genomic DNA was obtained having high molecular weight and good quality, shown by agarose gel electrophoresis and spectrophtometric analysis. These results shown that the modified method is simple, fast, safe, most economical, resulting in a high molecular genomic DNA of good quality from several mammalian tissues and can be used in medical laboratories and research centers.

  6. Effects of Zinc Supplementation on the Anthropometric Measurements, Lipid Profiles and Fasting Blood Glucose in the Healthy Obese Adults

    Directory of Open Access Journals (Sweden)

    Sepide Mahluji

    2013-02-01

    Full Text Available Purpose: The aim of this study was to assess the effects of zinc supplementation on anthropometric measures, improving lipid profile biomarkers, and fasting blood glucose level in obese people. Methods: This randomized, double- blind clinical trial was carried out on 60 obese participants in the 18-45 age range for one month. The participants were randomly divided into the intervention group, who received 30 mg/d zinc gluconate, and the placebo group who received 30mg/d starch. Anthropometric measurements (body mass index (BMI, weight and waist circumference were recorded before and at the end of study. Lipid profile biomarkers and fasting blood glucose were determined using enzymatic procedure. Analysis of Covariance (ANCOVA test was run to compare the post-treatment values of the two groups, and t-test was conducted to compare within group changes. Results: Serum zinc concentration was increased significantly in intervention group (p=0.024. BMI and body weight was significantly decreased (p=0.030 and p=0.020, respectively. Lipid profile biomarkers and fating blood glucose did not change significantly but triglyceride level was significantly decreased (p=0.006 in the intervention group. Conclusion: The obtained results indicate that zinc supplementation improves BMI, body weight, and triglyceride concentration without considerable effects on lipid profile and glucose level. Zinc can be suggested as a suitable supplementation therapy for obese people, but more studies are needed to verify the results.

  7. Barrier screens: a method to sample blood-fed and host-seeking exophilic mosquitoes

    Directory of Open Access Journals (Sweden)

    Burkot Thomas R

    2013-02-01

    Full Text Available Abstract Background Determining the proportion of blood meals on humans by outdoor-feeding and resting mosquitoes is challenging. This is largely due to the difficulty of finding an adequate and unbiased sample of resting, engorged mosquitoes to enable the identification of host blood meal sources. This is particularly difficult in the south-west Pacific countries of Indonesia, the Solomon Islands and Papua New Guinea where thick vegetation constitutes the primary resting sites for the exophilic mosquitoes that are the primary malaria and filariasis vectors. Methods Barrier screens of shade-cloth netting attached to bamboo poles were constructed between villages and likely areas where mosquitoes might seek blood meals or rest. Flying mosquitoes, obstructed by the barrier screens, would temporarily stop and could then be captured by aspiration at hourly intervals throughout the night. Results In the three countries where this method was evaluated, blood-fed females of Anopheles farauti, Anopheles bancroftii, Anopheles longirostris, Anopheles sundaicus, Anopheles vagus, Anopheles kochi, Anopheles annularis, Anopheles tessellatus, Culex vishnui, Culex quinquefasciatus and Mansonia spp were collected while resting on the barrier screens. In addition, female Anopheles punctulatus and Armigeres spp as well as male An. farauti, Cx. vishnui, Cx. quinquefasciatus and Aedes species were similarly captured. Conclusions Building barrier screens as temporary resting sites in areas where mosquitoes were likely to fly was an extremely time-effective method for collecting an unbiased representative sample of engorged mosquitoes for determining the human blood index.

  8. On Ultrasonic MTI Measurement of Velocity Profiles in Blood-Flow

    Directory of Open Access Journals (Sweden)

    Bjørn A.J. Angelsen

    1981-04-01

    Full Text Available A theoretical analysis of Doppler frequency estimators proposed to be used in ultrasonic MTI measurements of velocity profiles in blood flow, is given. The estimators give an output in form of a single analogue voltage and the relation of the output to the Doppler spectrum is discussed. Three new estimators are also proposed. All estimators work fairly well for narrow-band Doppler spectra, but errors are found when broad-band spectra are present.

  9. X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Lee, Sang Joon

    2016-01-01

    X-ray PIV measurement is a noninvasive approach to measure opaque blood flows. However, it is not easy to measure real pulsatile blood flows in the blood vessels located at deep position of the body, because the surrounding tissues significantly attenuate the contrast of X-ray images. This study investigated the effect of surrounding tissues on X-ray beam attenuation by measuring the velocity fields of blood flows in deep vessels of a live rat. The decrease in image contrast was minimized by employing biocompatible CO2 microbubbles as tracer particles. The maximum measurable velocity of blood flows in the abdominal aorta of a rat model was found through comparative examination between the PIV measurement accuracy and the level of image contrast according to the input flow rate. Furthermore, the feasibility of using X-ray PIV to accurately measure in vivo blood flows was demonstrated by determining the velocity field of blood flows in the inferior vena cava of a rat. This study may serve as a reference in conducting in vivo X-ray PIV measurements of pulsatile blood flows in animal disease models and investigating hemodynamic characteristics and circulatory vascular diseases.

  10. X-ray PIV measurement of blood flow in deep vessels of a rat: An in vivo feasibility study.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Lee, Sang Joon

    2016-01-18

    X-ray PIV measurement is a noninvasive approach to measure opaque blood flows. However, it is not easy to measure real pulsatile blood flows in the blood vessels located at deep position of the body, because the surrounding tissues significantly attenuate the contrast of X-ray images. This study investigated the effect of surrounding tissues on X-ray beam attenuation by measuring the velocity fields of blood flows in deep vessels of a live rat. The decrease in image contrast was minimized by employing biocompatible CO2 microbubbles as tracer particles. The maximum measurable velocity of blood flows in the abdominal aorta of a rat model was found through comparative examination between the PIV measurement accuracy and the level of image contrast according to the input flow rate. Furthermore, the feasibility of using X-ray PIV to accurately measure in vivo blood flows was demonstrated by determining the velocity field of blood flows in the inferior vena cava of a rat. This study may serve as a reference in conducting in vivo X-ray PIV measurements of pulsatile blood flows in animal disease models and investigating hemodynamic characteristics and circulatory vascular diseases.

  11. Non-invasive cerebral blood volume measurement during seizures using multi-channel near infrared spectroscopic topography

    Science.gov (United States)

    Watanabe, Eiju; Maki, Atsushi; Kawaguchi, Fumio; Yamashita, Yuichi; Koizumi, Hideaki; Mayanagi, Yoshiaki

    2000-07-01

    Near infrared spectroscopic topography (NIRS) is widely recognized as a noninvasive method to measure the regional cerebral blood volume (rCBV) dynamics coupled with neuronal activities. We analyzed the rCBV change in the early phase of epileptic seizures in 12 consecutive patients with medically intractable epilepsy. Seizure was induced by bemegride injection. We used eight-channel NIRS in nine cases and 24 channel in three cases. In all of the cases, rCBV increased rapidly after the seizure onset on the focus side. The increased rCBV was observed for about 30 - 60 s. The NIRS method can be applied to monitor the rCBV change continuously during seizures. Therefore, this method may be combined with ictal SPECT as one of the most reliable noninvasive methods of focus diagnosis.

  12. Development of a simple device for processing whole-blood samples into measured aliquots of plasma.

    Science.gov (United States)

    Burtis, C A; Johnson, W F; Walker, W A

    1986-09-01

    A capillary processor and aliquoter has been designed and fabricated that is capable of accepting aliquots of whole blood and automatically processing them into discrete aliquots of plasma. The device consists of two disks, each of which contains 16 individual capillaries and a processing rotor. One disk accepts larger capillaries that hold approximately 100 microL of whole blood each. The second disk accepts 2.54-cm-long precision capillaries of various internal diameters, which provide exact sample volumes from 1 to 10 microL. The processing rotor contains 16 individual compartments and chambers to accept both disks. Applying centrifugal force transfers the aliquots of whole blood into their respective compartments, where they are separated into cellular and plasma fractions. As the rotor speed is slowly decreased, an aliquot of plasma is withdrawn by capillary action into each measuring capillary. The disk containing the 16 measured aliquots of plasma is then removed and placed into a modified rotor for conventional centrifugal analysis. This device can entrain and deliver microliter volumes of liquids with precision and accuracy (1-2%) near that of mechanical pipettes. Assays of the separated plasma aliquots also have acceptable precision (e.g., CVs approximately 3% for measurements of serum enzymes).

  13. Measurement Methods in the field of benchmarking

    Directory of Open Access Journals (Sweden)

    István Szűts

    2004-05-01

    Full Text Available In benchmarking we often come across with parameters being difficultto measure while executing comparisons or analyzing performance, yet they haveto be compared and measured so as to be able to choose the best practices. Thesituation is similar in the case of complex, multidimensional evaluation as well,when the relative importance and order of different dimensions, parameters to beevaluated have to be determined or when the range of similar performanceindicators have to be decreased with regard to simpler comparisons. In suchcases we can use the ordinal or interval scales of measurement elaborated by S.S.Stevens.

  14. Comparison of uteroplacental blood flow in normal and pre-eclamptic patients measurement with technetium-99m and a computer-linked gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S.H.; Moon, H.; Kim, D.S.; Cho, S.S.

    1985-05-01

    Uteroplacental blood flow studies in preeclampsia are of special interest since the vascular changes reported in this disease might constitute a structural basis for a reduction of blood flow. Evidence has also been given for a decreased uteroplacental blood flow in preeclampsia. Among the various methods to estimate the maternal placental blood flow, the one most frequently reported in the literature during the last years has been the time activity analysis of short lived radiotracer such as technetium-99m or indium-113m injected intravenously. Only few studies with the above mentioned technique comparing normal and preeclampsia cases have been undertaken. In clinical practice we frequently experience difficuly in finding the optimal time to get the delivery in preeclampsia patients. The aim of this study was first to measure uteroplacental blood flow in preeclamptic pregnancies using a computer-linked gamma camera method for the time-activity analysis of technetium-99m and second to discuss the possibility of clinical application of these measurements for determination of fetal well-being and the timing of the delivery in these patients. Uteroplacental blood flow was measured from 13 preeclamptic patients and 19 pregnancies without any complication after 35 completed weeks of gestation from Jan. 1983 to Sep. 1983 at Obstetrics department of Hanyang University Hospital. (Author).

  15. Quantitative analysis and simultaneous activity measurements of Cu, Zn-superoxide dismutase in red blood cells by HPLC-ICPMS.

    Science.gov (United States)

    Nuevo Ordoñez, Y; Montes-Bayón, M; Blanco-González, E; Sanz-Medel, A

    2010-03-15

    The interest on accurate and precise determination of metalloproteins such as Cu, Zn-superoxide dismutase (Cu, Zn-SOD) involved in the redox balance of living cells is increasing. For this purpose, analytical strategies that provide absolute protein concentration measurements have to be developed. The determination of Cu, Zn-SOD through the measurement of the Cu associated to the protein, which provides its enzymatic activity, by liquid chromatography with online inductively coupled plasma mass spectrometric (ICPMS) detection is described here. Postcolumn isotope dilution analysis (IDA) of Cu has been applied for quantification after evaluation of the column recovery for the total Cu and also Cu-SOD that turned out to be quantitative. When the concentration results obtained via IDA using high-performance liquid chromatography (HPLC)-ICPMS are plotted versus the activity measurements (using the spectrophotometric pyrogallol autoxidation method) a good correlation curve is obtained. Such results permit us, from ICPMS measurements, to obtain simultaneously the Cu, Zn-SOD absolute concentration as well as its enzymatic activity by interpolation in the previously obtained curve. This possibility was explored in real samples (red blood cells of control individuals and patients with metallic total hip arthroplasty) obtaining a good match between direct enzymatic activity measurements and those obtained by interpolation in the correlation curve. The actual protein identification in the red blood cell extract was conducted by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS), and two matrixes were compared in order to preserve as much as possible the protein-metal interactions during the MALDI process. Interestingly, using a solution containing trihydroxyacetophenone in citrate buffer permitted us to observe some metal-protein interactions in the MS spectrum of the intact Cu, Zn-SOD from red blood cells.

  16. Validation of measurement protocols to assess oxygen consumption and blood flow in the human forearm by near-infrared spectroscopy

    Science.gov (United States)

    Van Beekvelt, Mireille C. P.; Colier, Willy N.; van Engelen, Baziel G. M.; Hopman, Maria T. E.; Wevers, Ron A.; Oeseburg, Berend

    1998-01-01

    Near infrared spectroscopy (NIRS) has been used to monitor oxygenation changes in muscle. Quantitative values for O2 consumption, blood flow and venous saturation have been reported by several investigators. The amount of these measurements is, however, still limited and complete validation has not yet been established. The aim of this study was to investigate the different NIRS methods to calculate O2 consumption (VO2) and forearm blood flow (FBF) and to validate the data with the accepted method of strain-gauge plethysmography and blood sampling. Thirteen subjects were tested in rest and during static isometric handgrip exercise at 10% MVC. The NIRS optodes were positioned on the flexor region of the arm. A significant correlation was found between plethysmograph data and NIRS [tHb] during venous occlusion in rest (r EQ 0.925 - 0.994, P exercise (r equals 0.895 - 0.990, P exercise. It seems that although NIRS is a good qualitative monitoring technique, quantification is difficult due to the great variability that is found between the subjects.

  17. [Automated measurement of reticulocyte count by flow cytometry. II: Analysis of the blood containing abnormal erythrocytes or giant platelets].

    Science.gov (United States)

    Oyamatsu, T; Shimizu, N; Takeu