WorldWideScience

Sample records for blood hemoglobin concentration

  1. Influence of peripheral blood hemoglobin concentration on the result of radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    He Beiwa; Zhang Guofen; Zhao Yutian; Wang Zhenwu; Xu Min; Hu Yulin

    2002-01-01

    Objective: To determine the influence of peripheral blood hemoglobin concentration on the radiotherapy result of nasopharyngeal carcinoma (NPC). Methods: From January 1989 to December 1998, 304 patients with pathologically confirmed NPC received radical radiation. There were 209 males and 95 females. The ages ranged from 16 to 77 years with a median of 42. All patients were irradiated by 60 Co or 6 MV external beam with a total dose of 64 - 76 Gy for the primary tumor and 46 - 77 Gy for the cervical lymph nodes. The peripheral blood hemoglobin concentration for all patients was measured before, during and after radiotherapy. These patients were divided into three groups according to the peripheral blood hemoglobin concentration before radiotherapy: anemia ( 160 g/L), and into two groups according to the change in the peripheral blood hemoglobin concentration during radiotherapy as increased and decreased groups. Results: All patients were followed with a follow-up rate of 90.5%. The peripheral blood hemoglobin concentration had a significant effect on the survival of NPC patients. Its decrease or increase during radiotherapy affected the survival and local control rates of NPC patients. Conclusions: The change of peripheral hemoglobin concentration affecting the oxygen content in the blood, can influence the local control and survival rates of NPC patients. Increase results in higher survival

  2. Effect of hemoglobin adjustment on the precision of mercury concentrations in maternal and cord blood

    DEFF Research Database (Denmark)

    Kim, Byung Mi; Choi, Anna L.; Ha, Eun Hee

    2014-01-01

    to be less precise than suggested by laboratory quality data, we studied the interrelationships of mercury concentrations with hemoglobin in paired maternal and cord blood samples from a Faroese birth cohort (N=514) and the Mothers and Children[U+05F3]s Environmental Health study in Korea (n=797). Linear...... and cord blood for hemoglobin improved their precision, while no significant effect of the selenium concentration in maternal blood was found. Adjustment of blood-mercury concentrations for hemoglobin is therefore recommended. © 2014 Elsevier Inc....

  3. Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system.

    Science.gov (United States)

    Jopling, Jeffery; Henry, Erick; Wiedmeier, Susan E; Christensen, Robert D

    2009-02-01

    "Reference ranges" are developed when it is impossible or inappropriate to establish "normal ranges" by drawing blood on healthy normal volunteers. Reference ranges for the hematocrit and the blood hemoglobin concentration of newborn infants have previously been reported from relatively small sample sizes by using measurement methods that now are considered outmoded. We sought to develop reference ranges for hematocrit and hemoglobin during the neonatal period (28 days) by using very large sample sizes and modern hematology analyzers, accounting for gestational and postnatal age and gender. Data were assembled from a multihospital health care system after exclusion of patients with a high likelihood of an abnormal value and those who were receiving blood transfusions. During the interval from 22 to 40 weeks' gestation, the hematocrit and blood hemoglobin concentration increased approximately linearly. For every week advance in gestational age, the hematocrit increased by 0.64% and the hemoglobin concentration increased by 0.21 g/dL. No difference was seen on the basis of gender. During the 4-hour interval after birth, hematocrit/hemoglobin values of late preterm and term neonates (35-42 weeks' gestation) increased by 3.6% +/- 0.5% (mean +/- SD), those of neonates of 29 to 34 weeks' gestation remained unchanged, and those of hematocrit/hemoglobin occurred. The figures presented herein describe reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period, accounting for gestational and postnatal age.

  4. Optoacoustic monitoring of blood hemoglobin concentration: a pilot clinical study

    Science.gov (United States)

    Petrova, Irina Y.; Esenaliev, Rinat O.; Petrov, Yuriy Y.; Brecht, Hans-Peter F.; Svensen, Christer H.; Olsson, Joel; Deyo, Donald J.; Prough, Donald S.

    2005-07-01

    The optoacoustic technique is noninvasive, has high spatial resolution, and potentially can be used to measure the total hemoglobin concentration ([THb]) continuously and accurately. We performed in vitro measurements in blood and in vivo tests in healthy volunteers. Our clinical protocol included rapid infusion of intravenous saline to simulate rapid change in the [THb] during fluid therapy or surgery. Optoacoustic measurements were made from the wrist area overlying the radial artery for more than 1 h. The amplitude of the optoacoustic signal generated in the radial artery closely followed the [THb] measured directly in concurrently collected blood samples.

  5. Respiratory properties of blood and hemoglobin solutions from the piranha

    DEFF Research Database (Denmark)

    Wood, S.C.; Weber, Roy E.; Powers, D.

    1979-01-01

    1. Respiratory properties of piranha blood are distinguished from those of other fish primarily by the high CO2 buffering capacity (?HCO3/-?pH= 19.6mmol/l for oxygenated blood and 39.1 mmol/l for deoxygenated blood). 2. The concentration of nucleoside triphosphates (NTP) and the half-saturation t......) lowered the oxygen affinity of purified hemoglobin solutions, accounting for the size-dependent correlation ofP50 and NTP concentration in whole blood. 5. While similar in concentration in red cells, GTP is more potent than ATP as an allosteric modifier of hemoglobin function....

  6. A microfluidic approach for hemoglobin detection in whole blood

    Directory of Open Access Journals (Sweden)

    Nikita Taparia

    2017-10-01

    Full Text Available Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  7. A microfluidic approach for hemoglobin detection in whole blood

    Science.gov (United States)

    Taparia, Nikita; Platten, Kimsey C.; Anderson, Kristin B.; Sniadecki, Nathan J.

    2017-10-01

    Diagnosis of anemia relies on the detection of hemoglobin levels in a blood sample. Conventional blood analyzers are not readily available in most low-resource regions where anemia is prevalent, so detection methods that are low-cost and point-of-care are needed. Here, we present a microfluidic approach to measure hemoglobin concentration in a sample of whole blood. Unlike conventional approaches, our microfluidic approach does not require hemolysis. We detect the level of hemoglobin in a blood sample optically by illuminating the blood in a microfluidic channel at a peak wavelength of 540 nm and measuring its absorbance using a CMOS sensor coupled with a lens to magnify the image onto the detector. We compare measurements in microchannels with channel heights of 50 and 115 μm and found the channel with the 50 μm height provided a better range of detection. Since we use whole blood and not lysed blood, we fit our data to an absorption model that includes optical scattering in order to obtain a calibration curve for our system. Based on this calibration curve and data collected, we can measure hemoglobin concentration within 1 g/dL for severe cases of anemia. In addition, we measured optical density for blood flowing at a shear rate of 500 s-1 and observed it did not affect the nonlinear model. With this method, we provide an approach that uses microfluidic detection of hemoglobin levels that can be integrated with other microfluidic approaches for blood analysis.

  8. Hemoglobin concentration determination based on near infrared spatially resolved transmission spectra

    Science.gov (United States)

    Zhang, Linna; Li, Gang; Lin, Ling

    2016-10-01

    Spatially resolved diffuse reflectance spectroscopy method has been proved to be more effective than single point spectroscopy method in the experiment to predict the concentration of the Intralipid diluted solutions. However, Intralipid diluted solution is simple, cannot be the representative of turbid liquids. Blood is a natural and meaningful turbid liquid, more complicate. Hemoglobin is the major constituent of the whole blood. And hemoglobin concentration is commonly used in clinical medicine to diagnose many diseases. In this paper, near infrared spatially resolved transmission spectra (NIRSRTS) and Partial Least Square Regression (PLSR) were used to predict the hemoglobin concentration of human blood. The results showed the prediction ability for hemoglobin concentration of the proposed method is better than single point transmission spectroscopy method. This paper demonstrated the feasibility of the spatially resolved diffuse reflectance spectroscopy method for practical liquid composition analysis. This research provided a new thinking of practical turbid liquid composition analysis.

  9. Blood hemoglobin level and treatment outcome of early breast cancer

    International Nuclear Information System (INIS)

    Henke, M.; Sindlinger, F.; Ikenberg, H.; Gerds, T.; Schumacher, M.

    2004-01-01

    Background and purpose: to determine whether the blood hemoglobin concentration correlates with the prognosis of patients with early breast cancer and, if so, whether this is restricted to treatment modality. Patients and methods: data were collected retrospectively from patients with early breast cancer (T1,2 NO-2 MO) who underwent either breast-conserving surgery followed by adjuvant radiotherapy (BCS-RT; n = 96) or a modified radical mastectomy (MRM; n = 194). The effect of preoperative blood hemoglobin level, nodal status, histological grading and hormone receptor status on disease-free survival was determined for both treatment modalities using a cox regression model and visualized by kaplan-meier plots. Results: the blood hemoglobin concentration significantly correlated with disease-free survival of patients receiving BCS-RT (relative risk [RR]: 0.67 per g/dl; p = 0.007). This was independent of other known risk factors for breast cancer patients, as determined by multivariate analysis. By contrast, the blood hemoglobin level had no prognostic significance when patients were treated with MRM. Conclusion: blood hemoglobin concentration seems to affect the prognosis of patients with early breast cancer when a treatment schedule that includes radiotherapy is applied. Reduced radiosensitivity due to diminished tumor oxygenation may be the underlying cause. Confirmative trials and studies intended to elucidate the underlying mechanism are warranted. (orig.)

  10. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    OpenAIRE

    Nuinoon, Manit; Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were ...

  11. Importance of hemoglobin concentration to exercise: acute manipulations

    DEFF Research Database (Denmark)

    Calbet, José A L; Lundby, Carsten; Koskolou, Maria

    2006-01-01

    An acute reduction of blood hemoglobin concentration ([Hb]), even when the circulating blood volume is maintained, results in lower (.)V(O(2)(max) and endurance performance, due to the reduction of the oxygen carrying capacity of blood. Conversely, an increase of [Hb] is associated with enhanced...

  12. Hemoglobin levels and blood transfusion in patients with sepsis in Internal Medicine Departments.

    Science.gov (United States)

    Muady, Gassan Fuad; Bitterman, Haim; Laor, Arie; Vardi, Moshe; Urin, Vitally; Ghanem-Zoubi, Nesrin

    2016-10-13

    Acute reduction in hemoglobin levels is frequently seen during sepsis. Previous studies have focused on the management of anemia in patients with septic shock admitted to intensive care units (ICU's), including aggressive blood transfusion aiming to enhance tissue oxygenation. To study the changes in hemoglobin concentrations during the first week of sepsis in the setting of Internal Medicine (IM) units, and their correlation to survival. Observational prospective study. We recorded hemoglobin values upon admission and throughout the first week of hospital stay in a consecutive cohort of septic patients admitted to IM units at a community hospital, the patients were enrolled into a prospective registry. Data on blood transfusions was also collected, we examined the correlation between hemoglobin concentrations during the first week of sepsis and survival, the effect of blood transfusion was also assessed. Eight hundred and fifteen patients (815) with sepsis were enrolled between February 2008 to January 2009. More than 20 % of them had hemoglobin levels less than 10g/dL on admission, a rate that was doubled during the first week of sepsis. Overall, 68 (8.3 %) received blood transfusions, 14 of them (20.6 %) due to bleeding. Typically, blood transfusion was given to older patients with a higher rate of malignancy and lower hemoglobin levels. While hemoglobin concentration on admission had strong correlation with in-hospital mortality (O.R-0.83 [95 % C.I. 0.74-0.92], blood transfusion was not found to be an independent predicting factor for mortality. Anemia is very common in sepsis. While hemoglobin level on admission exhibit independent correlation with survival, blood transfusion do not.

  13. Hemoglobin in samples with leukocytosis can be measured on ABL 700 series blood gas analyzers

    NARCIS (Netherlands)

    Scharnhorst, V.; Laar, van der P.D.; Vader, H.

    2003-01-01

    To compare lactate, bilirubin and Hemoglobin F concentrations obtained on ABL 700 series blood gas analyzers with those from laboratory methods. Pooled neonatal plasma, cord blood and adult plasma samples were used for comparison of bilirubin, hemoglobin F and lactate concentrations respectively.

  14. A new method for detecting hemoglobin directly in whole blood using photon attenuation techniques

    International Nuclear Information System (INIS)

    Medhat, M.E.

    2014-01-01

    The objective of the proposed work is focused on measuring iron concentration directly in whole blood as tool for estimating hemoglobin and anemic conditions in patients across the world. The investigated method depends on theory of photon attenuation through transmission of low energy in whole blood sample. The mathematical expressions for calculating hemoglobin and iron deficit on blood using photon attenuation are derived. Calculations are carried out for estimating concentration of iron in blood samples taken from children, adults and old patients and therefore measuring their hemoglobin and iron deficit from normal values. Theoretical mass attenuation coefficient values were obtained using the XCOM program. A high-resolution gamma-ray spectrometry based on high purity germanium detector was employed to measure attenuation of strongly collimated monoenergetic gamma beam through blood samples. (author)

  15. The Relationship Between Preoperative Hemoglobin Concentration, Use of Hospital Resources, and Outcomes in Cardiac Surgery.

    Science.gov (United States)

    Hallward, George; Balani, Nikhail; McCorkell, Stuart; Roxburgh, James; Cornelius, Victoria

    2016-08-01

    Preoperative anemia is an established risk factor associated with adverse perioperative outcomes after cardiac surgery. However, limited information exists regarding the relationship between preoperative hemoglobin concentration and outcomes. The aim of this study was to investigate how outcomes are affected by preoperative hemoglobin concentration in a cohort of patients undergoing cardiac surgery. A retrospective, observational cohort study. A single-center tertiary referral hospital. The study comprised 1,972 adult patients undergoing elective and nonelective cardiac surgery. The independent relationship of preoperative hemoglobin concentration was explored on blood transfusion rates, return to the operating room for bleeding and/or cardiac tamponade, postoperative intensive care unit (ICU) and in-hospital length of stay, and mortality. The overall prevalence of anemia was 32% (629/1,972 patients). For every 1-unit increase in hemoglobin (g/dL), blood transfusion requirements were reduced by 11%, 8%, and 3% for red blood cell units, platelet pools, and fresh frozen plasma units, respectively (adjusted incident rate ratio 0.89 [95% CI 0.87-0.91], 0.92 [0.88-0.97], and 0.97 [0.96-0.99]). For each 1-unit increase in hemoglobin (g/dL), the probability (over time) of discharge from the ICU and hospital increased (adjusted hazard ratio estimates 1.04 [1.00-1.08] and 1.12 [1.12-1.16], respectively). A lower preoperative hemoglobin concentration resulted in increased use of hospital resources after cardiac surgery. Each g/dL unit fall in preoperative hemoglobin concentration resulted in increased blood transfusion requirements and increased postoperative ICU and hospital length of stay. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Blood lead: Its effect on trace element levels and iron structure in hemoglobin

    International Nuclear Information System (INIS)

    Jin, C.; Li, Y.; Li, Y.L.; Zou, Y.; Zhang, G.L.; Normura, M.; Zhu, G.Y.

    2008-01-01

    Lead is a ubiquitous environmental pollutant that induce a broad range of physiological and biochemical dysfunctions. The purpose of this study was to investigate its effects on trace elements and the iron structure in hemoglobin. Blood samples were collected from rats that had been exposed to lead. The concentration of trace elements in whole blood and blood plasma was determined by ICP-MS and the results indicate that lead exists mainly in the red blood cells and only about 1-3% in the blood plasma. Following lead exposure, the concentrations of zinc and iron in blood decrease, as does the hemoglobin level. This indicates that the heme biosynthetic pathway is inhibited by lead toxicity and that lead poisoning-associated anemia occurs. The selenium concentration also decreases after lead exposure, which may lead to an increased rate of free radical production. The effect of lead in the blood on iron structure in hemoglobin was determined by EXAFS. After lead exposure, the Fe-O bond length increases by about 0.07 A and the Fe-Np bond length slightly increases, but the Fe-N ε bond length remains unchanged. This indicates that the blood content of Hb increases, but that the content of HbO 2 decreases

  17. FRET imaging of hemoglobin concentration in Plasmodium falciparum-infected red cells.

    Directory of Open Access Journals (Sweden)

    Alessandro Esposito

    Full Text Available During its intraerythrocytic asexual reproduction cycle Plasmodium falciparum consumes up to 80% of the host cell hemoglobin, in large excess over its metabolic needs. A model of the homeostasis of falciparum-infected red blood cells suggested an explanation based on the need to reduce the colloid-osmotic pressure within the host cell to prevent its premature lysis. Critical for this hypothesis was that the hemoglobin concentration within the host cell be progressively reduced from the trophozoite stage onwards.The experiments reported here were designed to test this hypothesis by direct measurements of the hemoglobin concentration in live, infected red cells. We developed a novel, non-invasive method to quantify the hemoglobin concentration in single cells, based on Förster resonance energy transfer between hemoglobin molecules and the fluorophore calcein. Fluorescence lifetime imaging allowed the quantitative mapping of the hemoglobin concentration within the cells. The average fluorescence lifetimes of uninfected cohorts was 270+/-30 ps (mean+/-SD; N = 45. In the cytoplasm of infected cells the fluorescence lifetime of calcein ranged from 290+/-20 ps for cells with ring stage parasites to 590+/-13 ps and 1050+/-60 ps for cells with young trophozoites and late stage trophozoite/early schizonts, respectively. This was equivalent to reductions in hemoglobin concentration spanning the range from 7.3 to 2.3 mM, in line with the model predictions. An unexpected ancillary finding was the existence of a microdomain under the host cell membrane with reduced calcein quenching by hemoglobin in cells with mature trophozoite stage parasites.The results support the predictions of the colloid-osmotic hypothesis and provide a better understanding of the homeostasis of malaria-infected red cells. In addition, they revealed the existence of a distinct peripheral microdomain in the host cell with limited access to hemoglobin molecules indicating the

  18. Diode laser irradiation of rat blood and its effect on hemoglobin and plasma

    International Nuclear Information System (INIS)

    Saad-El-Din, A.A.; El-Ahdaal, M.A.; Omran, M.F.

    2002-01-01

    Blood was exposed to diode laser irradiation of wavelength 830 nm and maximum powe of 31.4 MW, with exposure times 15, 30, 45 and 60 minutes. Hemoglobin IR spectra and X-ray crystallography, plasma Na + , K + , Ca + +. cholesterol concentrations and viscosity were measured. There were changes in hemoglobin amide groups as well as changes in the X-ray in hemoglobin structure. Decreases in both Na concentration and plasma viscosity occurred at 15 and 30 minutes of laser exposure. On increasing time to 45 and 60 minutes, the Na concentration and viscosity were increased. K, Ca and cholesterol concentration were decreased linearly with time. Na / K ratio was increased also with time of exposure. The results have been indicated that the diode laser affect the secondary structure of hemoglobin, membranes structures and plasma

  19. Genetic hemoglobin disorders rather than iron deficiency are a major predictor of hemoglobin concentration in women of reproductive age in rural prey Veng, Cambodia.

    Science.gov (United States)

    Karakochuk, Crystal D; Whitfield, Kyly C; Barr, Susan I; Lamers, Yvonne; Devlin, Angela M; Vercauteren, Suzanne M; Kroeun, Hou; Talukder, Aminuzzaman; McLean, Judy; Green, Timothy J

    2015-01-01

    Anemia is common in Cambodian women. Potential causes include micronutrient deficiencies, genetic hemoglobin disorders, inflammation, and disease. We aimed to investigate factors associated with anemia (low hemoglobin concentration) in rural Cambodian women (18-45 y) and to investigate the relations between hemoglobin disorders and other iron biomarkers. Blood samples were obtained from 450 women. A complete blood count was conducted, and serum and plasma were analyzed for ferritin, soluble transferrin receptor (sTfR), folate, vitamin B-12, retinol binding protein (RBP), C-reactive protein (CRP), and α1 acid glycoprotein (AGP). Hemoglobin electrophoresis and multiplex polymerase chain reaction were used to determine the prevalence and type of genetic hemoglobin disorders. Overall, 54% of women had a genetic hemoglobin disorder, which included 25 different genotypes (most commonly, hemoglobin E variants and α(3.7)-thalassemia). Of the 420 nonpregnant women, 29.5% had anemia (hemoglobin 8.3 mg/L), hemoglobin disorders, respectively. There was no biochemical evidence of vitamin A deficiency (RBP 5 mg/L) and 26% (AGP >1 g/L) of nonpregnant women, respectively. By using an adjusted linear regression model, the strongest predictors of hemoglobin concentration were hemoglobin E homozygous disorder and pregnancy status. Other predictors were 2 other heterozygous traits (hemoglobin E and Constant Spring), parity, RBP, log ferritin, and vitamin B-12. Multiple biomarkers for anemia and iron deficiency were significantly influenced by the presence of hemoglobin disorders, hence reducing their diagnostic sensitivity. Further investigation of the unexpectedly low prevalence of IDA in Cambodian women is warranted. © 2015 American Society for Nutrition.

  20. Partial Least Square with Savitzky Golay Derivative in Predicting Blood Hemoglobin Using Near Infrared Spectrum

    Directory of Open Access Journals (Sweden)

    Mohd Idrus Mohd Nazrul Effendy

    2018-01-01

    Full Text Available Near infrared spectroscopy (NIRS is a reliable technique that widely used in medical fields. Partial least square was developed to predict blood hemoglobin concentration using NIRS. The aims of this paper are (i to develop predictive model for near infrared spectroscopic analysis in blood hemoglobin prediction, (ii to establish relationship between blood hemoglobin and near infrared spectrum using a predictive model, (iii to evaluate the predictive accuracy of a predictive model based on root mean squared error (RMSE and coefficient of determination rp2. Partial least square with first order Savitzky Golay (SG derivative preprocessing (PLS-SGd1 showed the higher performance of predictions with RMSE = 0.7965 and rp2= 0.9206 in K-fold cross validation. Optimum number of latent variable (LV and frame length (f were 32 and 27 nm, respectively. These findings suggest that the relationship between blood hemoglobin and near infrared spectrum is strong, and the partial least square with first order SG derivative is able to predict the blood hemoglobin using near infrared spectral data.

  1. Oxygenation level and hemoglobin concentration in experimental tumor estimated by diffuse optical spectroscopy

    Science.gov (United States)

    Orlova, A. G.; Kirillin, M. Yu.; Volovetsky, A. B.; Shilyagina, N. Yu.; Sergeeva, E. A.; Golubiatnikov, G. Yu.; Turchin, I. V.

    2017-07-01

    Using diffuse optical spectroscopy the level of oxygenation and hemoglobin concentration in experimental tumor in comparison with normal muscle tissue of mice have been studied. Subcutaneously growing SKBR-3 was used as a tumor model. Continuous wave fiber probe diffuse optical spectroscopy system was employed. Optical properties extraction approach was based on diffusion approximation. Decreased blood oxygen saturation level and increased total hemoglobin content were demonstrated in the neoplasm. The main reason of such differences between tumor and norm was significant elevation of deoxyhemoglobin concentration in SKBR-3. The method can be useful for diagnosis of tumors as well as for study of blood flow parameters of tumor models with different angiogenic properties.

  2. Graphene based chalcogenide fiber-optic evanescent wave sensor for detection of hemoglobin in human blood

    Science.gov (United States)

    Sharma, Anuj K.; Gupta, Jyoti

    2018-03-01

    Fiber optic evanescent wave sensor with graphene as an absorption-enhancing layer to measure hemoglobin concentration in human blood is proposed. Previous modal functions and experimental results describing the variation of optical constants of human blood with different hemoglobin concentrations in the near-infrared spectral region are considered for sensor design simulation. The sensor's performance is closely analyzed in terms of its absorption coefficient, sensitivity, and detection limit. It is found that the proposed sensor should be operated at longer light wavelength to get more enhanced sensitivity and smaller detection limit. At 1000 nm wavelength, a detection limit of 18 μg/dL and sensitivity of 6.71 × 10-4 per g/dL is achievable with the proposed sensor. The sensitivity is found to be better for larger hemoglobin concentrations. The results are correlated with the evanescent wave penetration depth.

  3. Validation of NIRS in measuring tissue hemoglobin concentration and oxygen saturation on ex vivo and isolated limb models

    Science.gov (United States)

    Xu, Xiaorong; Zhu, Wen; Padival, Vikram; Xia, Mengna; Cheng, Xuefeng; Bush, Robin; Christenson, Linda; Chan, Tim; Doherty, Tim; Iatridis, Angelo

    2003-07-01

    Photonify"s tissue spectrometer uses Near-Infrared Spectroscopy for real-time, noninvasive measurement of hemoglobin concentration and oxygen saturation [SO2] of biological tissues. The technology was validated by a series of ex vivo and animal studies. In the ex vivo experiment, a close loop blood circulation system was built, precisely controlling the oxygen saturation and the hemoglobin concentration of a liquid phantom. Photonify"s tissue spectrometer was placed on the surface of the liquid phantom for real time measurement and compared with a gas analyzer, considered the gold standard to measure oxygen saturation and hemoglobin concentration. In the animal experiment, the right hind limb of each dog accepted onto the study was surgically removed. The limb was kept viable by connecting the femoral vein and artery to a blood-primed extracorporeal circuit. Different concentrations of hemoglobin were obtained by adding designated amount of saline solution into the perfusion circuit. Photonify"s tissue spectrometers measured oxygen saturation and hemoglobin concentration at various locations on the limb and compared with gas analyzer results. The test results demonstrated that Photonify"s tissue spectrometers were able to detect the relative changes in tissue oxygen saturation and hemoglobin concentration with a high linear correlation compared to the gas analyzer

  4. Fasting blood glucose and haemoglobin concentrations of healthy ...

    African Journals Online (AJOL)

    Menstruation is associated with loss of blood monthly in women of reproductive age. In some women this physiological phenomenon is also associated with some complaints such as menstrual pain, vomiting, and tiredness. We investigated the fasting blood glucose concentration and hemoglobin concentration before and ...

  5. A retrospective cohort study of blood hemoglobin levels in blood donors and competitive rowers

    DEFF Research Database (Denmark)

    Johansson, P.I.; Ullum, H.; Jensen, K.

    2009-01-01

    To investigate the distribution of blood hemoglobin levels in healthy blood donors and elite athletes, a retrospective cohort study from 2001 to 2005 of candidate blood donors and elite rowers in Denmark was performed. Eighty-five thousand eight hundred and forty-six blood donors were identified.......3% of the females demonstrated values above the recommended limit for athletic competition. Thus, the prevalence of a high hemoglobin value was greater in the rowers, of both gender, than in the candidate blood donors (Pblood are seen regularly in normal...... (36 962 males), and 3.9% of the males had a blood hemoglobin above 10.5 mM, equalling a hematocrit of 51% and, 1.6% of the females had hemoglobin above 9.7 mM, corresponding to a hematocrit above 47%. One thousand four hundred and six rowers (1116 males) were investigated and 10.4% of the males and 8...

  6. Removal of cellular-type hemoglobin-based oxygen carrier (hemoglobin-vesicles) from blood using centrifugation and ultrafiltration.

    Science.gov (United States)

    Sakai, Hiromi; Sou, Keitaro; Horinouchi, Hirohisa; Tsuchida, Eishun; Kobayashi, Koichi

    2012-02-01

    The hemoglobin-vesicle (HbV) is an artificial oxygen carrier encapsulating a concentrated hemoglobin solution in a phospholipid vesicle (liposome). During or after transporting oxygen, macrophages capture HbVs in the reticuloendothelial system (RES) with an approximate circulation half-life of 3 days. Animal studies show transient splenohepatomegaly after large doses, but HbVs were completely degraded, and the components were excreted in a few weeks. If a blood substitute is used for emergency use until red blood cell transfusion becomes available or for temporary use such as a priming fluid for an extracorporeal circuit, then one option would be to remove HbVs from the circulating blood without waiting a few weeks for removal by the RES. Using a mixture of beagle dog whole blood and HbV, we tested the separation of HbV using a centrifugal Fresenius cell separator and an ultrafiltration system. The cell separator system separated the layers of blood cell components from the HbV-containing plasma layer by centrifugal force, and then the HbV was removed from plasma phase by the ultrafiltration system. The HbVs (250-280 nm) are larger than plasma proteins (blood cell components (> 3 µm). The size of HbVs is advantageous to be separated from the original blood components, and the separated blood components can be returned to circulation. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  7. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Directory of Open Access Journals (Sweden)

    Manit Nuinoon

    2014-01-01

    Full Text Available Thalassemia and hemoglobin E (Hb E are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%, heterozygous α-thalassemia 1 (1.7%, heterozygous β-thalassemia without α-thalassemia (0.9%, heterozygous Hb E without α-thalassemia (5.2%, double heterozygotes for Hb E/α-thalassemia 1 (1.7%, homozygous Hb E without α-thalassemia (0.9%, and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%. The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors.

  8. Thalassemia and Hemoglobin E in Southern Thai Blood Donors

    Science.gov (United States)

    Kruachan, Kwanta; Sengking, Warachaya; Horpet, Dararat; Sungyuan, Ubol

    2014-01-01

    Thalassemia and hemoglobin E (Hb E) are common in Thailand. Individuals with thalassemia trait usually have a normal hemoglobin concentration or mild anemia. Therefore, thalassemic individuals who have minimum acceptable Hb level may be accepted as blood donors. This study was aimed at determining the frequency of α-thalassemia 1 trait, β-thalassemia trait, and Hb E-related syndromes in Southern Thai blood donors. One hundred and sixteen voluntary blood donors, Southern Thailand origin, were recruited for thalassemia and Hb E screening by red blood cell indices/dichlorophenolindophenol precipitation test. β-Thalassemia and Hb E were then identified by high performance liquid chromatography and 4 common α-thalassemia deletions were characterized by a single tube-multiplex gap-polymerase chain reaction. Overall frequency of hemoglobinopathies was 12.9%, classified as follows: homozygous α-thalassemia 2 (1.7%), heterozygous α-thalassemia 1 (1.7%), heterozygous β-thalassemia without α-thalassemia (0.9%), heterozygous Hb E without α-thalassemia (5.2%), double heterozygotes for Hb E/α-thalassemia 1 (1.7%), homozygous Hb E without α-thalassemia (0.9%), and homozygous Hb E with heterozygous α-thalassemia 2 (0.9%). The usefulness of thalassemia screening is not only for receiving highly effective red blood cells in the recipients but also for encouraging the control and prevention program of thalassemia in blood donors. PMID:25050123

  9. Hemoglobin Function in Stored Blood.

    Science.gov (United States)

    1974-08-01

    States during 1973. Several advantages over ACA) are important. Blood stored in CPD maintains higher ./ levels of 2,3-DPG (2,3- diphosphoglycerate ) and a...survival and ATP levels in stored blood is explained by the several functions of ATP which are necessary for cell viability. However, ATP levels do...not correlate with oxygen affinity during storage. Levels of 2,3-DPG determine oxygen affinity and thus hemoglobin function. (12,13) When normal levels

  10. Monitor hemoglobin concentration and oxygen saturation in living mouse tail using photoacoustic CT scanner

    Science.gov (United States)

    Liu, Bo; Kruger, Robert; Reinecke, Daniel; Stantz, Keith M.

    2010-02-01

    Purpose: The purpose of this study is to use PCT spectroscopy scanner to monitor the hemoglobin concentration and oxygen saturation change of living mouse by imaging the artery and veins in a mouse tail. Materials and Methods: One mouse tail was scanned using the PCT small animal scanner at the isosbestic wavelength (796nm) to obtain its hemoglobin concentration. Immediately after the scan, the mouse was euthanized and its blood was extracted from the heart. The true hemoglobin concentration was measured using a co-oximeter. Reconstruction correction algorithm to compensate the acoustic signal loss due to the existence of bone structure in the mouse tail was developed. After the correction, the hemoglobin concentration was calculated from the PCT images and compared with co-oximeter result. Next, one mouse were immobilized in the PCT scanner. Gas with different concentrations of oxygen was given to mouse to change the oxygen saturation. PCT tail vessel spectroscopy scans were performed 15 minutes after the introduction of gas. The oxygen saturation values were then calculated to monitor the oxygen saturation change of mouse. Results: The systematic error for hemoglobin concentration measurement was less than 5% based on preliminary analysis. Same correction technique was used for oxygen saturation calculation. After correction, the oxygen saturation level change matches the oxygen volume ratio change of the introduced gas. Conclusion: This living mouse tail experiment has shown that NIR PCT-spectroscopy can be used to monitor the oxygen saturation status in living small animals.

  11. Comparative and quantitative determination of total hemoglobin concentration in normal and psoriatic patients

    International Nuclear Information System (INIS)

    Mahesar, S.M.; Dahot, M.U.; Khuhawar, M.Y.; Mahesar, H.U.

    2004-01-01

    The cyanmethaemoglobin technique is now recommended as the standard method by International Committee for Standardization in Hematology and British Standards Institution 1966. The hemoglobin is treated with reagent containing potassium ferricyanide, Potassium cyanide and potassium dihydrogen phosphate. The ferricyanide forms methamoglobin which is converted to cyanmethaemoglobin by the cyanide. The average values of hemoglobin, percent determined from the blood samples of normal and psoriatic (n=44) males and (n=35) females were 15.0, 12.7, 13.6 and 11.2 g/100ml. The decrease in hemoglobin concentration could be due to anemia resulting during the cell proliferation epidermis in inflammatory state and Keratolytic disorder which take place in psoriasis. (author)

  12. Small angle X-ray scattering on concentrated hemoglobin solutions

    International Nuclear Information System (INIS)

    Zinke, M.; Damaschun, G.; Mueller, J.J.; Ruckpaul, K.

    1978-01-01

    The small-angle X-ray scattering technique was used to determine the intermolecular structure and interaction potentials in oxi-and deoxi-hemoglobin solutions. The pair correlation function obtained by the ZERNICKE-PRINS equation characterizes the intermolecular structure of the hemoglobin molecules. The intermolecular structure is concentration dependent. The hemoglobin molecules have a 'short range order structure' with a range of about 4 molecule diameters at 324 g/l. The potential functions of the hemoglobin-hemoglobin interaction have been determined on the basis of fluid theories. Except for the deoxi-hemoglobin solution having the concentration 370 g/l, the pair interaction consists in a short repulsion and a weak short-range attraction against kT. The potential minimum is between 1.2 - 1.5 nm above the greatest hemoglobin diameter. (author)

  13. Predictors of hemoglobin in Danish blood donors

    DEFF Research Database (Denmark)

    Kotzé, Sebastian R; Pedersen, Ole B; Petersen, Mikkel S

    2015-01-01

    BACKGROUND: It is well known that blood donors are at increased risk of iron deficiency and subsequent development of iron deficiency anemia. We aimed to investigate the effect of factors influencing hemoglobin (Hb) levels. STUDY DESIGN AND METHODS: Initiated in 2010, the Danish Blood Donor Study...

  14. The effect of a standardized protocol for iron supplementation to blood donors low in hemoglobin concentration.

    Science.gov (United States)

    Magnussen, Karin; Bork, Nanna; Asmussen, Lisa

    2008-04-01

    Iron deficiency leading to low hemoglobin concentration (cHb) is a common problem for blood donors as well as for blood banks. A standardized protocol offering iron supplementation based on P-ferritin determination may help to reduce the problem and retain donors. This was a prospective study where 879 blood donors, presenting with cHb at or below the limit of acceptance for donation, were included. The predonation cHb result was read after donation. The donors received 50 iron tablets (JernC or Ferrochel, 100 or 25 mg elemental iron, respectively), and samples for P-ferritin, mean corpuscular volume, and control of cHb were secured. Based on a P-ferritin level of less than 60 microg per L, 20 iron tablets were offered after all following donations. Mean cHb was 7.6 mmol per L (122 g/L) and 8.2 mmol per L (132 g/L) in women and men, respectively. In 80 percent of the women and 48 percent of the men, iron stores were low (P-ferritin protocol offering iron supplementation and simple oral and written advice based on P-ferritin measurements is effective in normalizing cHb and retaining donors presenting with cHb at or below the limit of acceptance for donation.

  15. Customization of Advia 120 thresholds for canine erythrocyte volume and hemoglobin concentration, and effects on morphology flagging results.

    Science.gov (United States)

    Grimes, Carolyn N; Fry, Michael M

    2014-12-01

    This study sought to develop customized morphology flagging thresholds for canine erythrocyte volume and hemoglobin concentration [Hgb] on the ADVIA 120 hematology analyzer; compare automated morphology flagging with results of microscopic blood smear evaluation; and examine effects of customized thresholds on morphology flagging results. Customized thresholds were determined using data from 52 clinically healthy dogs. Blood smear evaluation and automated morphology flagging results were correlated with mean cell volume (MCV) and cellular hemoglobin concentration mean (CHCM) in 26 dogs. Customized thresholds were applied retroactively to complete blood (cell) count (CBC) data from 5 groups of dogs, including a reference sample group, clinical cases, and animals with experimentally induced iron deficiency anemia. Automated morphology flagging correlated more highly with MCV or CHCM than did blood smear evaluation; correlation with MCV was highest using customized thresholds. Customized morphology flagging thresholds resulted in more sensitive detection of microcytosis, macrocytosis, and hypochromasia than default thresholds.

  16. Time course for the recovery of physical performance, blood hemoglobin, and ferritin content after blood donation

    DEFF Research Database (Denmark)

    Ziegler, Andreas K; Grand, Johannes; Stangerup, Ida

    2015-01-01

    BACKGROUND: It is widely accepted that blood donation negatively affects endurance performance, but data on physical recovery after a standard blood donation are scarce. This study aimed to elucidate the temporary impact of blood donation on endurance performance, measured as peak oxygen uptake (VO......2peak ) and time trial (TT) performance. STUDY DESIGN AND METHODS: VO2peak , TT performance, blood, iron, and anthropometric variables were determined before (baseline) and 3, 7, 14, and 28 days after blood donation in 19 healthy men. RESULTS: VO2peak was reduced by 6.5% from 49.7 ± 2 m......L/kg/min at baseline to 46.3 ± 2 mL/kg/min on Day 3 (p donation. Blood hemoglobin (Hb) concentration declined 7.9% from 9.3 ± 0.11 mmol...

  17. Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A(1c), IgA, prolactin, and free testosterone in healthy women

    DEFF Research Database (Denmark)

    Garde, A H; Hansen, Åse Marie; Skovgaard, L T

    2000-01-01

    Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within......- (CV(i)) and between-subject (CV(g)) CVs for healthy women. In addition, the index of individuality, prediction intervals, and power calculations were derived....

  18. Prognostic value of hemoglobin concentration in radiotherapy for cancer of supraglottic larynx

    International Nuclear Information System (INIS)

    Tarnawski, Rafal; Skladowski, Krzysztof; Maciejewski, Boguslaw

    1997-01-01

    Purpose: The aim of this work is the estimation of correlations between hemoglobin concentration either before or after radiotherapy and local tumor control probability for laryngeal cancer. Methods and Materials: Retrospective analysis of 847 cases of laryngeal supraglottic squamous cell carcinoma treated with radiation alone was performed using maximum likelihood estimations, and step-wise logistic regression. All patients were in good initial performance status (Karnofsky index >70). The minimum follow-up time was 3 years. Results: Logistic regression showed that the hemoglobin concentration after radiotherapy is an important prognostic factor. There was a very strong correlation between hemoglobin concentration and tumor local control probability. Hemoglobin concentration at the beginning of radiotherapy does not correlate with treatment outcome, but any decrease of hemoglobin during therapy is a strong prognostic factor for treatment failure. Conclusions: Although regression models with many variables may be instable, the present results suggest that hemoglobin concentration after treatment is at least as important as overall treatment time. It was not possible to find out whether the low concentration of hemoglobin is an independent cause of low TCP or whether it reflects other mechanisms that may influence both hemoglobin level and the TCP

  19. Study of LAXS Profile of Hemoglobin from Irradiated Blood

    International Nuclear Information System (INIS)

    Selim, N.S.; Desouky, O.S.; Elshemey, W.M.

    2006-01-01

    The present work aims to move a step forward towards a deeper understanding of the scattering of x-ray, from lyophilized biological samples. Comparative study has been performed using low angle x-ray scattering (LAXS) and UV-visible spectrophotometry for monitoring the dose response characteristics of the hemoglobin molecule of irradiated blood. Blood samples were exposed to gamma rays, at doses ranging from 5 up to 100 Gy. Diluted hemoglobin solution was scanned in the UV-visible range (200-700 nm), and lyophilized hemoglobin was prepared for LAXS measurement. The radiation-induced changes in the hemoglobin structure have been evaluated. The LAXS profile of hemoglobin molecule is characterized by the presence of 2 peaks in the forward direction of scattering. These peaks were found to be sensitive to the variations in the molecular structure of a given sample. The obtained results suggest that the 1st peak, recorded at 4.65O (equivalent to momentum transfer, x= 0.526 nm-1), is sensitive to the tertiary and quaternary structure of the globin part, while the major peak, recorded at 10.5O (equivalent to momentum transfer, x= 1.189 nm-1), appeared to be related to its primary and secondary structure

  20. Operative time, blood loss, hemoglobin drop, blood transfusion, and hospital stay in orthognathic surgery.

    Science.gov (United States)

    Salma, Ra'ed Ghaleb; Al-Shammari, Fahad Mohammed; Al-Garni, Bishi Abdullah; Al-Qarzaee, Mohammed Abdullah

    2017-06-01

    This study was conducted to evaluate the operative time, blood loss, hemoglobin drop, blood transfusion, and length of hospital stay in orthognathic surgery. A 10-year retrospective analysis was performed on patients who underwent bilateral sagittal split osteotomy (with or without genioplasty), Le Fort I osteotomy (with or without genioplasty), or any combination of these procedures. A total of 271 patients were included. The age range was 17 to 49 years, with a mean age of 24.13 ± 4.51 years. Approximately 62% of patients underwent double-jaw surgery. The most common procedure was bilateral sagittal split with Le Fort I (37%). The average operative time was 3.96 ± 1.25 h. The mean estimated blood loss was 345.2 ± 149.74 mL. Approximately 9% of patients received intraoperative blood transfusion. The mean hemoglobin drop in the non-transfusion cases was 2.38 ± 0.89 g/dL. The mean postoperative hospital stay was 1.85 ± 0.83 days. Only one patient was admitted to the ICU for one night. In orthognathic surgery, blood loss is relatively minor, blood transfusion is frequent, and ICU admission is unlikely. Operative time, blood loss, blood transfusion, and the complexity of the surgical procedure can significantly increase the length of hospital stay. Males may bleed more than females in orthognathic surgery. Hemoglobin drop can be overestimated due to hemodilution in orthognathic surgery, which may influence the decision to use blood transfusion.

  1. Handling low hemoglobin and iron deficiency in a blood donor population

    DEFF Research Database (Denmark)

    Magnussen, Karin; Ladelund, Steen

    2016-01-01

    BACKGROUND: Iron deficiency and blood donors with low hemoglobin (Hb) concentration are well-known challenges in any blood bank setting. In the Capital Region of Denmark, a new approach was adopted that centralized measurement of Hb, initiated ferritin (F) measurement, and established a center......: The change in Hb for repeat donors was followed during the first 2 years of the intervention strategy, which included measurements of F and offering intermittent iron supplementation to some of the donors. RESULTS: In 2 years, 62,663 blood donors donated 193,288 units of blood and 318 donors gave 754...... complete blood count blood samples. Over time in the repeat donors, the Hb increased from 15.39 to 15.60 g/dL and 13.85 to 14.06 g/dL in male and female donors, respectively, and the proportion of donors with low Hb decreased from 0.9% to 0.3% and 3.9% to 2.7% for the male and female donors, respectively...

  2. Raman Tweezers as a Diagnostic Tool of Hemoglobin-Related Blood Disorders

    Directory of Open Access Journals (Sweden)

    Giulia Rusciano

    2008-12-01

    Full Text Available This review presents the development of a Raman Tweezers system for detecting hemoglobin-related blood disorders at a single cell level. The study demonstrates that the molecular fingerprint insight provided by Raman analysis holds great promise for distinguishing between healthy and diseased cells in the field of biomedicine. Herein a Raman Tweezers system has been applied to investigate the effects of thalassemia, a blood disease quite diffuse in the Mediterranean Sea region. By resonant excitation of hemoglobin Raman bands, we examined the oxygenation capability of normal, alpha- and beta-thalassemic erythrocytes. A reduction of this fundamental red blood cell function, particularly severe for beta-thalassemia, has been found. Raman spectroscopy was also used to draw hemoglobin distribution inside single erythrocytes; the results confirmed the characteristic anomaly (target shape, occurring in thalassemia and some other blood disorders. The success of resonance Raman spectroscopy for thalassemia detection reported in this review provide an interesting starting point to explore the application of a Raman Tweezers system in the analysis of several blood disorders.

  3. Optical wavelength selection for portable hemoglobin determination by near-infrared spectroscopy method

    Science.gov (United States)

    Tian, Han; Li, Ming; Wang, Yue; Sheng, Dinggao; Liu, Jun; Zhang, Linna

    2017-11-01

    Hemoglobin concentration is commonly used in clinical medicine to diagnose anemia, identify bleeding, and manage red blood cell transfusions. The golden standard method for determining hemoglobin concentration in blood requires reagent. Spectral methods were advantageous at fast and non-reagent measurement. However, model calibration with full spectrum is time-consuming. Moreover, it is necessary to use a few variables considering size and cost of instrumentation, especially for a portable biomedical instrument. This study presents different wavelength selection methods for optical wavelengths for total hemoglobin concentration determination in whole blood. The results showed that modelling using only two wavelengths combination (1143 nm, 1298 nm) can keep on the fine predictability with full spectrum. It appears that the proper selection of optical wavelengths can be more effective than using the whole spectra for determination hemoglobin in whole blood. We also discussed the influence of water absorptivity on the wavelength selection. This research provides valuable references for designing portable NIR instruments determining hemoglobin concentration, and may provide some experience for noninvasive hemoglobin measurement by NIR methods.

  4. Hemoglobin, red blood cell count, hematocrit and derived parameters for diagnosing anemia in elderly males

    International Nuclear Information System (INIS)

    Khan, Z.; Nawaz, M.

    2013-01-01

    Anemia is one of the most common micronutrient deficiency in our community. Nutritional anaemias are caused when there is an inadequate body store of a specific nutrient needed for hemoglobin synthesis. The most common nutrient deficiency is of iron. Therefore, a cross-sectional survey was conducted on the healthy elderly male, aged >= 40 and 77 years (n=60) volunteers in order to assess their blood parameters, such as hemoglobin concentration (Hb), hematocrit (HCT), red blood cell count (RBC), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH) and mean corpuscular hemoglobin concentration (MCHC) for the diagnosis of anemia. The demographic results showed mean values (50.10+-8.79) years for age, 66-68 +- 1.95 inches for height , 71.43 +- 6.43 kg body weight, 98.34+-0.48 degree F body temperature, 124 +- 8.67 systolic blood pressure, 82.17 +- 4.15 diastolic pressure while, The pulse rate was found to be 74.63 +- 7.02/minute. Similarly, mean values for lean body weight (LBW) found to be 49.9+-2.89, ideal body weight (IBW) 60.9 +- 4.49, body surface area (BSA) was 1.8 +- 0.1 m2 whereas, body mass index (BMI) showed mean value 24.9 +- 2.6 kg/m2. More so, overall mean Hb found to be 13.60 g/dl, RBC 4.6 mill/mm3, HCT/PCV 43%, MCV 92.95fl, MCH 29.42 pg and MCHC was found to be 31.73 g/dl. The normal range of Hb for men was 13-17 g/dl and 31.67% of the subjects participated in the study was considered to be anemic showing less Hb than normal range. The volunteers were suggested to improve the dietary habits and to take iron supplements in order to overcome the iron deficiency anemia. (author)

  5. Prediction models for hemoglobin deferral in whole blood donors

    NARCIS (Netherlands)

    Baart, A.M.

    2013-01-01

    Each year, a relevant proportion of the invited blood donors is eventually deferred from donation because of low hemoglobin (Hb) levels. Deferrals are meant to protect donors from developing iron deficiency anemia after a blood donation, however, they may increase the risk of donor lapse, even

  6. Blood pressure reduction due to hemoglobin glycosylation in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Pedro Cabrales

    2008-08-01

    Full Text Available Pedro Cabrales1, Miguel A Salazar Vázquez2,3, Beatriz Y Salazar Vázquez3,4, Martha Rodríguez-Morán5, Marcos Intaglietta4, Fernando Guerrero-Romero51La Jolla Bioengineering Institute, La Jolla, California, USA; 2Hospital Regional No. 1, of the Mexican Social Security Institute, Victoria de Durango, Dgo. Mexico; 3Faculty of Medicine and Dept. of Physical Chemistry, Universidad Juárez del Estado de Durango, Victoria de Durango, Dgo. Mexico; 4Department of Bioengineering, University of California, San Diego, La Jolla, California, USA; 5Biomedical Research Unit, of the Mexican Social Security Institute, Victoria de Durango, Dgo. MexicoObjective: To test the hypothesis that glycosylation of hemoglobin constitutes a risk factor for hypertension.Methods: A total of 129 relative uniform diabetic subjects (86 women and 42 men were enrolled in a cross-sectional study. Exclusion criteria included alcohol consumption, smoking, ischemic heart disease, stroke, neoplasia, renal, hepatic, and chronic inflammatory disease. Systolic and diastolic pressures were recorded in subsequent days and mean arterial blood pressure (MAP was determined. Hemoglobin glycosylation was measured by determining the percentage glycosylated hemoglobin (HbA1c by means of the automated microparticle enzyme immunoassay test.Results: MAP was found to be independent of the concentration of HbA1c; however, correcting MAP for the variability in hematocrit, to evidence the level of vasoconstriction (or vasodilatation showed that MAP is negatively correlated with the concentration of HbA1c (p for trend <0.05, when patients treated for hypertension are excluded from the analysis. Patients treated for hypertension showed the opposite trend with increasing MAP as HbA1c increased (p for the difference in trends <0.05.Conclusions: Glycosylation per se appears to lead to blood pressure reduction in type 2 diabetic patients untreated for hypertension. Treatment for hypertension may be

  7. Treatment of β-Thalassemia/Hemoglobin E with Antioxidant Cocktails Results in Decreased Oxidative Stress, Increased Hemoglobin Concentration, and Improvement of the Hypercoagulable State

    Directory of Open Access Journals (Sweden)

    Orn-uma Yanpanitch

    2015-01-01

    Full Text Available Studies on the antioxidant treatment for thalassemia have reported variable outcomes. However, treatment of thalassemia with a combination of hydrophobic and hydrophilic antioxidants and an iron chelator has not been studied. This study investigated the effects of antioxidant cocktails for the treatment of β-thalassemia/hemoglobin E (HbE, which is the most common form of β-thalassemia in Southeast Asia. Sixty patients were divided into two groups receiving N-acetylcysteine, deferiprone, and either curcuminoids (CUR or vitamin E (Vit-E, and their hematological parameters, iron load, oxidative stress, and blood coagulation potential were evaluated. Patients were classified as responders if they showed the improvements of the markers of iron load and oxidative stress, otherwise as nonresponders. During treatment, the responders in both groups had significantly decreased iron load, oxidative stress, and coagulation potential and significantly increased antioxidant capacity and hemoglobin concentration. The significantly maximum increase (P<0.01 in hemoglobin concentration was 11% at month 4 in CUR group responders and 10% at month 10 in Vit-E group responders. In conclusion, the two antioxidant cocktails can improve anemia, iron overload, oxidative stress, and hypercoagulable state in β-thalassemia/HbE.

  8. Hemoglobin Concentration and Risk of Incident Stroke in Community-Living Adults.

    Science.gov (United States)

    Panwar, Bhupesh; Judd, Suzanne E; Warnock, David G; McClellan, William M; Booth, John N; Muntner, Paul; Gutiérrez, Orlando M

    2016-08-01

    In previous observational studies, hemoglobin concentrations have been associated with an increased risk of stroke. However, these studies were limited by a relatively low number of stroke events, making it difficult to determine whether the association of hemoglobin and stroke differed by demographic or clinical factors. Using Cox proportional hazards analysis and Kaplan-Meier plots, we examined the association of baseline hemoglobin concentrations with incident stroke in the Reasons for Geographic and Racial Differences in Stroke (REGARDS) study, a cohort of black and white adults aged ≥45 years. A total of 518 participants developed stroke over a mean 7±2 years of follow-up. There was a statistically significant interaction between hemoglobin and sex (P=0.05) on the risk of incident stroke. In Cox regression models adjusted for demographic and clinical variables, there was no association of baseline hemoglobin concentration with incident stroke in men, whereas in women, the lowest (14.0 g/dL) quartiles of hemoglobin were associated with higher risk of stroke when compared with the second quartile (12.4-13.2 g/dL; quartile 1: hazard ratio, 1.59; 95% confidence interval, 1.09-2.31; quartile 2: referent; quartile 3: hazard ratio, 0.91; 95% confidence interval, 0.59-1.38; quartile 4: hazard ratio, 1.59; 95% confidence interval, 1.08-2.35). Similar results were observed in models stratified by hemoglobin and sex and when hemoglobin was modeled as a continuous variable using restricted quadratic spline regression. Lower and higher hemoglobin concentrations were associated with a higher risk of incident stroke in women. No such associations were found in men. © 2016 American Heart Association, Inc.

  9. Effect of Repeated Whole Blood Donations on Aerobic Capacity and Hemoglobin Mass in Moderately Trained Male Subjects: A Randomized Controlled Trial.

    Science.gov (United States)

    Meurrens, Julie; Steiner, Thomas; Ponette, Jonathan; Janssen, Hans Antonius; Ramaekers, Monique; Wehrlin, Jon Peter; Vandekerckhove, Philippe; Deldicque, Louise

    2016-12-01

    The aims of the present study were to investigate the impact of three whole blood donations on endurance capacity and hematological parameters and to determine the duration to fully recover initial endurance capacity and hematological parameters after each donation. Twenty-four moderately trained subjects were randomly divided in a donation (n = 16) and a placebo (n = 8) group. Each of the three donations was interspersed by 3 months, and the recovery of endurance capacity and hematological parameters was monitored up to 1 month after donation. Maximal power output, peak oxygen consumption, and hemoglobin mass decreased (p donation with a maximal decrease of 4, 10, and 7%, respectively. Hematocrit, hemoglobin concentration, ferritin, and red blood cell count (RBC), all key hematological parameters for oxygen transport, were lowered by a single donation (p donations (p donation was 11% for hematocrit, 10% for hemoglobin concentration, 50% for ferritin, and 12% for RBC (p donation group. Maximal, but not submaximal, endurance capacity was altered after blood donation in moderately trained people and the expected increase in capacity after multiple maximal exercise tests was not present when repeating whole blood donations.

  10. 76 FR 51041 - Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop

    Science.gov (United States)

    2011-08-17

    ...] Hemoglobin Standards and Maintaining Adequate Iron Stores in Blood Donors; Public Workshop AGENCY: Food and... Donors.'' The purpose of this public workshop is to discuss blood donor hemoglobin and hematocrit qualification standards in the United States, its impact on donor safety and blood availability, and potential...

  11. Quantification of extra-cerebral and cerebral hemoglobin concentrations during physical exercise using time-domain near infrared spectroscopy.

    Science.gov (United States)

    Auger, Héloïse; Bherer, Louis; Boucher, Étienne; Hoge, Richard; Lesage, Frédéric; Dehaes, Mathieu

    2016-10-01

    Fitness is known to have beneficial effects on brain anatomy and function. However, the understanding of mechanisms underlying immediate and long-term neurophysiological changes due to exercise is currently incomplete due to the lack of tools to investigate brain function during physical activity. In this study, we used time-domain near infrared spectroscopy (TD-NIRS) to quantify and discriminate extra-cerebral and cerebral hemoglobin concentrations and oxygen saturation ( SO 2 ) in young adults at rest and during incremental intensity exercise. In extra-cerebral tissue, an increase in deoxy-hemoglobin ( HbR ) and a decrease in SO 2 were observed while only cerebral HbR increased at high intensity exercise. Results in extra-cerebral tissue are consistent with thermoregulatory mechanisms to dissipate excess heat through skin blood flow, while cerebral changes are in agreement with cerebral blood flow ( CBF ) redistribution mechanisms to meet oxygen demand in activated regions during exercise. No significant difference was observed in oxy- ( HbO 2 ) and total hemoglobin ( HbT ). In addition HbO 2 , HbR and HbT increased with subject's peak power output (equivalent to the maximum oxygen volume consumption; VO 2 peak) supporting previous observations of increased total mass of red blood cells in trained individuals. Our results also revealed known gender differences with higher hemoglobin in men. Our approach in quantifying both extra-cerebral and cerebral absolute hemoglobin during exercise may help to better interpret past and future continuous-wave NIRS studies that are prone to extra-cerebral contamination and allow a better understanding of acute cerebral changes due to physical exercise.

  12. An innovative simple technique of blood conservation in adult patients with tetralogy of Fallot and severely raised hemoglobin.

    Science.gov (United States)

    Neema, Praveen Kumar; Manikandan, Sethuraman; Rathod, Ramesh Chandra

    2007-12-01

    The adult patients of tetralogy of Fallot often present with high hemoglobin levels. High hemoglobin and hematocrit on cardiopulmonary bypass (CPB) are associated with increased hemolysis, plasma free hemoglobin, renal dysfunction or failure, postoperative bleeding, exploration for bleeding, and increased requirement of allogeneic blood and blood products. Despite the presence of high hemoglobin and its association with adverse outcome, blood conservation is rarely practiced in these patients because of the fear of possible hemodynamic instability, and hypoxemic spell. We describe an innovative, simple technique of blood conservation for adult patients of tetralogy of Fallot with severely raised hemoglobin. With this technique, hemoglobin can be normalized on CPB; moreover, there is no fear of hypoxemic spell or hemodynamic instability. Furthermore, the blood conserved is readily available for transfusion in the perioperative period, if needed.

  13. An Innovative Simple Technique of Blood Conservation in Adult Patients with Tetralogy of Fallot and Severely Raised Hemoglobin

    OpenAIRE

    Neema, Praveen Kumar; Manikandan, Sethuraman; Rathod, Ramesh Chandra

    2007-01-01

    The adult patients of tetralogy of Fallot often present with high hemoglobin levels. High hemoglobin and hematocrit on cardiopulmonary bypass (CPB) are associated with increased hemolysis, plasma free hemoglobin, renal dysfunction or failure, postoperative bleeding, exploration for bleeding, and increased requirement of allogeneic blood and blood products. Despite the presence of high hemoglobin and its association with adverse outcome, blood conservation is rarely practiced in these patients...

  14. Oxygen Measurements in Liposome Encapsulated Hemoglobin

    Science.gov (United States)

    Phiri, Joshua Benjamin

    Liposome encapsulated hemoglobins (LEH's) are of current interest as blood substitutes. An analytical methodology for rapid non-invasive measurements of oxygen in artificial oxygen carriers is examined. High resolution optical absorption spectra are calculated by means of a one dimensional diffusion approximation. The encapsulated hemoglobin is prepared from fresh defibrinated bovine blood. Liposomes are prepared from hydrogenated soy phosphatidylcholine (HSPC), cholesterol and dicetylphosphate using a bath sonication method. An integrating sphere spectrophotometer is employed for diffuse optics measurements. Data is collected using an automated data acquisition system employing lock-in -amplifiers. The concentrations of hemoglobin derivatives are evaluated from the corresponding extinction coefficients using a numerical technique of singular value decomposition, and verification of the results is done using Monte Carlo simulations. In situ measurements are required for the determination of hemoglobin derivatives because most encapsulation methods invariably lead to the formation of methemoglobin, a nonfunctional form of hemoglobin. The methods employed in this work lead to high resolution absorption spectra of oxyhemoglobin and other derivatives in red blood cells and liposome encapsulated hemoglobin (LEH). The analysis using singular value decomposition method offers a quantitative means of calculating the fractions of oxyhemoglobin and other hemoglobin derivatives in LEH samples. The analytical methods developed in this work will become even more useful when production of LEH as a blood substitute is scaled up to large volumes.

  15. Effects of Hemoglobin-Based Oxygen Carriers on Blood Coagulation

    Directory of Open Access Journals (Sweden)

    Kimia Roghani

    2014-12-01

    Full Text Available For many decades, Hemoglobin-based oxygen carriers (HBOCs have been central in the development of resuscitation agents that might provide oxygen delivery in addition to simple volume expansion. Since 80% of the world population lives in areas where fresh blood products are not available, the application of these new solutions may prove to be highly beneficial (Kim and Greenburg 2006. Many improvements have been made to earlier generation HBOCs, but various concerns still remain, including coagulopathy, nitric oxide scavenging, platelet interference and decreased calcium concentration secondary to volume expansion (Jahr et al. 2013. This review will summarize the current challenges faced in developing HBOCs that may be used clinically, in order to guide future research efforts in the field.

  16. 21 CFR 864.7500 - Whole blood hemoglobin assays.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Whole blood hemoglobin assays. 864.7500 Section 864.7500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Hematology Kits and Packages § 864.7500 Whole...

  17. Hemoglobin as a factor in the control of tumor oxygenation

    International Nuclear Information System (INIS)

    Hirst, D.G.

    1987-01-01

    The concentration of hemoglobin in the blood has been shown to have a market effect on the radiosensitivity of human and animal tumors. Experimental studies in mice indicate that radiosensitivity is influenced by a change in the hemoglobin level rather than by the absolute concentration. This dependence may be exploited to therapeutic advantage. Recent studies of hemoglobin/oxygen affinity have shown that the concentration of 2,3 diphosphoglycerate (2,3 DPG) affects tumor sensitivity to X-rays. Increased 2,3 DPG levels increase radiosensitivity in several mouse tumors. The time dependence of this effect remains to be established. The effective application of these effects in man may depend on the development of drugs which produce changes in hemoglobin affinity without the need for blood transfusions. Several drugs are currently being investigated

  18. Crystallization and preliminary X-ray structural studies of hemoglobin A2 and hemoglobin E, isolated from the blood samples of β-thalassemic patients

    International Nuclear Information System (INIS)

    Dasgupta, Jhimli; Sen, Udayaditya; Choudhury, Debi; Datta, Poppy; Chakrabarti, Abhijit; Chakrabarty, Sudipa Basu; Chakrabarty, Amit; Dattagupta, J.K.

    2003-01-01

    Hemoglobin A 2 (α 2 δ 2 ), a minor (2-3%) component of circulating red blood cells, acts as an anti-sickling agent and its elevated concentration in β-thalassemia is a useful clinical diagnostic. In β-thalassemia major, where there is a failure of β-chain production, HbA 2 acts as the predominant oxygen deliverer. Hemoglobin E, is another common abnormal hemoglobin, caused by splice site mutation in exon 1 of β globin gene, when combines with β-thalassemia, causes severe microcytic anemia. The purification, crystallization, and preliminary structural studies of HbA 2 and HbE are reported here. HbA 2 and HbE are purified by cation exchange column chromatography in presence of KCN from the blood samples of individuals suffering from β-thalassemia minor and Eβ-thalassemia. X-ray diffraction data of HbA 2 and HbE were collected upto 2.1 and 1.73 A, respectively. HbA 2 crystallized in space group P2 1 with unit cell parameters a=54.33 A, b=83.73 A, c=62.87 A, and β=99.80 degree sign whereas HbE crystallized in space group P2 1 2 1 2 1 with unit cell parameters a=60.89 A, b=95.81 A, and c=99.08 A. Asymmetric unit in each case contains one Hb tetramer in R 2 state

  19. Hemoglobin concentrations and associated factors in adolescentes from Recife, Brazil

    OpenAIRE

    Elisângela Barros Soares Mendonça; Lilian Ferreira Muniz; Ilma Kruze Grande de Arruda; Alcides da Silva Diniz

    2014-01-01

    OBJECTIVE: To estimate the prevalence of anemia and associated factors in adolescents from the city of Recife in Pernambuco state. METHODS: This is a cross-sectional study, involving a random sample of 256 adolescents of both genders, aged 13 to 18, whose hemoglobin concentrations were evaluated, along with their nutritional status and socioeconomic and demographic characteristics. RESULTS: The prevalence of inadequate hemoglobin concentrations was 10.2% [CI95%=6.7-14.5], reaching levels cons...

  20. Correlation of Oxygenated Hemoglobin Concentration and Psychophysical Amount on Speech Recognition

    Science.gov (United States)

    Nozawa, Akio; Ide, Hideto

    The subjective understanding on oral language understanding task is quantitatively evaluated by the fluctuation of oxygenated hemoglobin concentration measured by the near-infrared spectroscopy. The English listening comprehension test wihch consists of two difficulty level was executed by 4 subjects during the measurement. A significant correlation was found between the subjective understanding and the fluctuation of oxygenated hemoglobin concentration.

  1. Exploring the relationship of peripheral total bilirubin, red blood cell, and hemoglobin with blood pressure during childhood and adolescence.

    Science.gov (United States)

    Chen, Xiao-Tian; Yang, Song; Yang, Ya-Ming; Zhao, Hai-Long; Chen, Yan-Chun; Zhao, Xiang-Hai; Wen, Jin-Bo; Tian, Yuan-Rui; Yan, Wei-Li; Shen, Chong

    2017-11-04

    Total bilirubin is beneficial for protecting cardiovascular diseases in adults. The authors aimed to investigate the association of total bilirubin, red blood cell, and hemoglobin levels with the prevalence of high blood pressure in children and adolescents. A total of 3776 students (aged from 6 to 16 years old) were examined using cluster sampling. Pre-high blood pressure and high blood pressure were respectively defined as the point of 90th and 95th percentiles based on the Fourth Report on the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents. Both systolic and diastolic blood pressure were standardized into z-scores. Peripheral total bilirubin, red blood cell and hemoglobin levels were significantly correlated with age, and also varied with gender. Peripheral total bilirubin was negatively correlated with systolic blood pressure in 6- and 9-year-old boys, whilst positively correlated with diastolic blood pressure in the 12-year-old boys and 13- to 15-year-old girls (p0.05). Total bilirubin could be weakly correlated with both systolic and diastolic blood pressure, as correlations varied with age and gender in children and adolescents; in turn, the increased levels of red blood cell and hemoglobin are proposed to be positively associated with the prevalence of high blood pressure. Copyright © 2017 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  2. A novel type of electrochemical sensor based on ferromagnetic carbon-encapsulated iron nanoparticles for direct determination of hemoglobin in blood samples.

    Science.gov (United States)

    Matysiak, Edyta; Donten, Mikolaj; Kowalczyk, Agata; Bystrzejewski, Michal; Grudzinski, Ireneusz P; Nowicka, Anna M

    2015-02-15

    An effective, fast, facile and direct electrochemical method of determination of hemoglobin (Hb) in blood sample without any sample preparation is described. The method is accomplished by using the ferromagnetic electrode modifier (carbon-encapsulated iron nanoparticles) and an external magnetic field. The successful voltammetric determination of hemoglobin is achieved in PBS buffer as well as in the whole blood sample. The obtained results show the excellent electroactivity of Hb. The measurements are of high sensitivity and good reproducibility. The detection limit is estimated to be 0.7 pM. The electrochemical determination data were compared with the gravimetric data obtained with a quartz crystal microbalance. The agreement between these results is very good. The changes of the electrode surface morphology before and after Hb detection are monitored by electron microscopy. The functionality of the electrochemical sensor is tested with human and rat blood samples. The concentration of hemoglobin in the blood samples determined by using voltammetric/gravimetric detection is in perfect agreement with the data obtained from typical clinical analysis. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. The Correlation of Hemoglobin A1c to Blood Glucose

    OpenAIRE

    Sikaris, Ken

    2009-01-01

    The understanding that hemoglobin A1c (HbA1c) represents the average blood glucose level of patients over the previous 120 days underlies the current management of diabetes. Even in making such a statement, we speak of “average blood glucose” as though “blood glucose” were itself a simple idea. When we consider all the blood glucose forms—arterial versus venous versus capillary, whole blood versus serum versus fluoride-preserved plasma, fasting versus nonfasting—we can start to see that this ...

  4. Action of carbon monoxide on the affinity of hemoglobin for oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Vanuxem, D.; Weiller, P.J.; Guillot, C.; Grimaud, C.

    1982-01-01

    The authors have studied the action of carbon monoxide on the affinity of hemoglobin for oxygen by measuring P50 in whole blood and in stripped hemoglobin before and after exposition of blood samples from heavy smokers and polycythemic patients with high levels of HbCO to hyperbaric oxygen (2.2 ata). The concentration of 2,3-diphosphoglycerate was normal although P50 was significantly lowered, not only in whole blood but also in stripped hemoglobin. Hyperbaric oxygen normalized P50 by removing CO radicals from stripped hemoglobin. This may indicate that CO radicals exert a direct action on the hemoglobin molecule, at least at the HbCO levels studied in this work.

  5. Age estimation of blood stains by hemoglobin derivative determination using reflectance spectroscopy

    NARCIS (Netherlands)

    Bremmer, Rolf H.; Nadort, Annemarie; van Leeuwen, Ton G.; van Gemert, Martin J. C.; Aalders, Maurice C. G.

    2011-01-01

    Blood stains can be crucial in reconstructing crime events. However, no reliable methods are currently available to establish the age of a blood stain on the crime scene. We show that determining the fractions of three hemoglobin derivatives in a blood stain at various ages enables relating these

  6. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting

    Directory of Open Access Journals (Sweden)

    Idriss Ali

    2011-04-01

    Full Text Available Abstract Background In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. Method EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin. Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC was used to determine the within subject variability of measured hemoglobin. Results Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p Conclusion Hemoglobin determined by the HemoCue method is comparable to that determined by the other methods. The HemoCue photometer is therefore recommended for use as on-the-spot device for determining hemoglobin in resource poor setting.

  7. Whole Blood Donation Affects the Interpretation of Hemoglobin A1c

    NARCIS (Netherlands)

    Dijkstra, Angelique; Lenters-Westra, Erna; de Kort, Wim; Bokhorst, Arlinke G.; Bilo, Henk J. G.; Slingerland, Robbert J.; Vos, Michel J.

    2017-01-01

    Several factors, including changed dynamics of erythrocyte formation and degradation, can influence the degree of hemoglobin A1c (HbA1c) formation thereby affecting its use in monitoring diabetes. This study determines the influence of whole blood donation on HbA1c in both non-diabetic blood donors

  8. Capillary versus Venous Hemoglobin Determination in the Assessment of Healthy Blood Donors

    Science.gov (United States)

    Patel, Abhilasha J.; Wesley, Robert; Leitman, Susan F.; Bryant, Barbara J.

    2013-01-01

    Background and Objectives To determine the accuracy of fingerstick hemoglobin assessment in blood donors, the performance of a portable hemoglobinometer (HemoCue Hb 201+) was prospectively compared with that of an automated hematology analyzer (Cell-Dyn 4000). Hemoglobin values obtained by the latter were used as the “true” result. Material and Methods Capillary fingerstick samples were assayed by HemoCue in 150 donors. Fingerstick samples from two sites, one on each hand, were obtained from a subset of 50 subjects. Concurrent venous samples were tested using both HemoCue and Cell-Dyn devices. Results Capillary hemoglobin values (HemoCue) were significantly greater than venous hemoglobin values (HemoCue), which in turn were significantly greater than venous hemoglobin values by Cell-Dyn (mean ± SD: 14.05 ± 1.51, 13.89 ± 1.31, 13.62 ± 1.23, respectively; phemoglobin screening criteria (≥12.5 g/dL) by capillary HemoCue, but were deferred by Cell-Dyn values (false-pass). Five donors (3%) were deferred by capillary sampling, but passed by Cell-Dyn (false-fail). Substantial variability in repeated fingerstick HemoCue results was seen (mean hemoglobin 13.72 vs. 13.70 g/dL, absolute mean difference between paired samples 0.76 g/dL). Hand dominance was not a factor. Conclusions Capillary samples assessed via a portable device yielded higher hemoglobin values than venous samples assessed on an automated analyzer. False-pass and false-fail rates were low and acceptable in the donor screening setting, with “true” values not differing by a clinically significant degree from threshold values used to assess acceptability for blood donation. PMID:23294266

  9. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease

  10. Rheological Variations among Nigerians with Different Hemoglobin ...

    African Journals Online (AJOL)

    Some Hemorheological determinants such as whole blood viscosity (WBV) and plasma viscosity (PV) and Plasma Fibrinogen Concentration (PFC) were measured with standard methods. We recorded a relatively unchanged whole blood viscosities in subjects with various hemoglobin genotypes (AA, AS and SS; P>0.05, ...

  11. Effect of age on heart rate, blood lactate concentration, packed cell volume and hemoglobin to exercise in Jeju crossbreed horses

    Directory of Open Access Journals (Sweden)

    Ok-Deuk Kang

    2017-01-01

    Full Text Available Abstract Background This study aimed to analyze the on heart rate, blood lactate concentration, packed cell volume (PCV and hemoglobin (Hb response after conducting exercise in endurance horses. Methods A total of 20 healthy 3–9-years-old Jeju crossbreed mares (5.95 ± 2.24 year of age and 312.65 ± 13.59 kg of weight currently participating the endurance competition were used. The field tests selected for the experiment was gallop (approximately 8.3 m/s along the selected 2.5 km course (a natural forest trail, not artificial road; a closed loop course. The horses were divided into three groups according to their age; 3–4 years of age (G1, 3.29 ± 0.49 year, 6–7 years of age (G2, 6.42 ± 0.53, and 8–9 years of age (G3, 8.50 ± 0.55. The measurements times for the heart rate, blood lactate concentration, PCV, and Hb analysis were conducted before exercise (T0, shortly after exercise (T1, 15 min after exercise (T2, and 30 min after exercise (T3, respectively. Data was analyzed using an analysis of covariance (ANCOVA for repeated measures with times and groups. Results The results of the comparison depending on the passage of rest time after exercise suggest that the heart rate and blood lactate concentration of three groups at T2 significantly decreased compared to T1 (p < 0.001. PCV of the G2 and G3 groups were significantly decreased at T2 compared to T1 (p < 0.01. Hb values at G2 (p < 0.01 and G3 (p < 0.001 groups were significantly decreased at T2 as compared to T1. However, heart rate, blood lactate concentration, PCV and Hb level at T1 showed no difference in the comparison of horses from different age groups with the exception of G3 group in terms of heart rate. Conclusion The physiologic and hematological responses of horses during recovery time after 2,500 m exercise with gallop were no significant difference among the groups. These data are useful as a response evaluation method for

  12. (Pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution as blood substitute for normothermic whole body rinse-out.

    Science.gov (United States)

    Agishi, T; Funakoshi, Y; Honda, H; Yamagata, K; Kobayashi, M; Takahashi, M

    1988-01-01

    In order to investigate a new possibility for artificial blood with oxygen-carrying capability to be applied to other than mere supplementation, normothermic whole body rinse-out in which artificial blood deriving from perfluorochemical emulsion, Fluosol-DA 20% (Green Cross Co., Ltd., Osaka, Japan) or stabilized hemoglobin solution, (pyridoxylated hemoglobin)-(polyoxyethylene) conjugate solution (Ajinomoto Co., Ltd., Tokyo, Japan) were used as rinsing fluid for a blood purification experiment. Replacement either with approximately 150 ml/kg of Fluosol-DA or stabilized hemoglobin solution showed effective removal of digoxin at a reduction rate of 96.3% or 92.2%, respectively. However, when Fluosol-DA was used, a certain amount of perfluorochemical should be retrieved by centrifugation to avoid a possible toxic effect on the reticulo-endothelial system. Even though 3 out of 6, and 3 out of 8 dogs, respectively, survived for a long period after the procedure, the experimental dogs were very susceptible to infection.

  13. Hemoglobin C disease

    Science.gov (United States)

    Clinical hemoglobin C ... Hemoglobin C is an abnormal type of hemoglobin, the protein in red blood cells that carries oxygen. It is ... Americans. You are more likely to have hemoglobin C disease if someone in your family has had ...

  14. Evaluation of non cyanide methods for hemoglobin estimation

    Directory of Open Access Journals (Sweden)

    Vinaya B Shah

    2011-01-01

    Full Text Available Background: The hemoglobincyanide method (HiCN method for measuring hemoglobin is used extensively worldwide; its advantages are the ready availability of a stable and internationally accepted reference standard calibrator. However, its use may create a problem, as the waste disposal of large volumes of reagent containing cyanide constitutes a potential toxic hazard. Aims and Objective: As an alternative to drabkin`s method of Hb estimation, we attempted to estimate hemoglobin by other non-cyanide methods: alkaline hematin detergent (AHD-575 using Triton X-100 as lyser and alkaline- borax method using quarternary ammonium detergents as lyser. Materials and Methods: The hemoglobin (Hb results on 200 samples of varying Hb concentrations obtained by these two cyanide free methods were compared with a cyanmethemoglobin method on a colorimeter which is light emitting diode (LED based. Hemoglobin was also estimated in one hundred blood donors and 25 blood samples of infants and compared by these methods. Statistical analysis used was Pearson`s correlation coefficient. Results: The response of the non cyanide method is linear for serially diluted blood samples over the Hb concentration range from 3gm/dl -20 gm/dl. The non cyanide methods has a precision of + 0.25g/dl (coefficient of variation= (2.34% and is suitable for use with fixed wavelength or with colorimeters at wavelength- 530 nm and 580 nm. Correlation of these two methods was excellent (r=0.98. The evaluation has shown it to be as reliable and reproducible as HiCN for measuring hemoglobin at all concentrations. The reagents used in non cyanide methods are non-biohazardous and did not affect the reliability of data determination and also the cost was less than HiCN method. Conclusions: Thus, non cyanide methods of Hb estimation offer possibility of safe and quality Hb estimation and should prove useful for routine laboratory use. Non cyanide methods is easily incorporated in hemobloginometers

  15. Evaluation of light scattering properties and chromophore concentrations in skin tissue based on diffuse reflectance signals at isosbestic wavelengths of hemoglobin

    Science.gov (United States)

    Yokokawa, Takumi; Nishidate, Izumi

    2016-04-01

    We investigate a method to evaluate light-scattering properties and chromophore concentrations in human skin tissue through diffuse reflectance spectroscopy using the reflectance signals acquired at isosbestic wavelengths of hemoglobin (420, 450, 500, and 585 nm). In the proposed method, Monte Carlo simulation-based empirical formulas are used to specify the scattering parameters of skin tissue, such as the scattering amplitude a and the scattering power b, as well as the concentration of melanin C m and the total blood concentration C tb. The use of isosbestic wavelengths of hemoglobin enables the values of C m, C tb, a, and b to be estimated independently of the oxygenation of hemoglobin. The spectrum of the reduced scattering coefficient is reconstructed from the scattering parameters. Experiments using in vivo human skin tissues were performed to confirm the feasibility of the proposed method for evaluating the changes in scattering properties and chromophore concentrations in skin tissue. The experimental results revealed that light scattering is significantly reduced by the application of a glycerol solution, which indicates an optical clearing effect due to osmotic dehydration and the matching of the refractive indices of scatterers in the epidermis.

  16. Inhibition mechanisms of hemoglobin, immunoglobulin G, and whole blood in digital and real-time PCR.

    Science.gov (United States)

    Sidstedt, Maja; Hedman, Johannes; Romsos, Erica L; Waitara, Leticia; Wadsö, Lars; Steffen, Carolyn R; Vallone, Peter M; Rådström, Peter

    2018-04-01

    Blood samples are widely used for PCR-based DNA analysis in fields such as diagnosis of infectious diseases, cancer diagnostics, and forensic genetics. In this study, the mechanisms behind blood-induced PCR inhibition were evaluated by use of whole blood as well as known PCR-inhibitory molecules in both digital PCR and real-time PCR. Also, electrophoretic mobility shift assay was applied to investigate interactions between inhibitory proteins and DNA, and isothermal titration calorimetry was used to directly measure effects on DNA polymerase activity. Whole blood caused a decrease in the number of positive digital PCR reactions, lowered amplification efficiency, and caused severe quenching of the fluorescence of the passive reference dye 6-carboxy-X-rhodamine as well as the double-stranded DNA binding dye EvaGreen. Immunoglobulin G was found to bind to single-stranded genomic DNA, leading to increased quantification cycle values. Hemoglobin affected the DNA polymerase activity and thus lowered the amplification efficiency. Hemoglobin and hematin were shown to be the molecules in blood responsible for the fluorescence quenching. In conclusion, hemoglobin and immunoglobulin G are the two major PCR inhibitors in blood, where the first affects amplification through a direct effect on the DNA polymerase activity and quenches the fluorescence of free dye molecules, and the latter binds to single-stranded genomic DNA, hindering DNA polymerization in the first few PCR cycles. Graphical abstract PCR inhibition mechanisms of hemoglobin and immunoglobulin G (IgG). Cq quantification cycle, dsDNA double-stranded DNA, ssDNA single-stranded DNA.

  17. The effect of oral iron with or without multiple micronutrients on hemoglobin concentration and hemoglobin response among nonpregnant Cambodian women of reproductive age: a 2 x 2 factorial, double-blind, randomized controlled supplementation trial.

    Science.gov (United States)

    Karakochuk, Crystal D; Barker, Mikaela K; Whitfield, Kyly C; Barr, Susan I; Vercauteren, Suzanne M; Devlin, Angela M; Hutcheon, Jennifer A; Houghton, Lisa A; Prak, Sophonneary; Hou, Kroeun; Chai, Tze Lin; Stormer, Ame; Ly, Sokhoing; Devenish, Robyn; Oberkanins, Christian; Pühringer, Helene; Harding, Kimberly B; De-Regil, Luz M; Kraemer, Klaus; Green, Tim J

    2017-07-01

    Background: Despite a high prevalence of anemia among nonpregnant Cambodian women, current reports suggest that iron deficiency (ID) prevalence is low. If true, iron supplementation will not be an effective anemia reduction strategy. Objective: We measured the effect of daily oral iron with or without multiple micronutrients (MMNs) on hemoglobin concentration in nonpregnant Cambodian women screened as anemic. Design: In this 2 × 2 factorial, double-blind, randomized trial, nonpregnant women (aged 18-45 y) with hemoglobin concentrations ≤117 g/L (capillary blood) were recruited from 26 villages in Kampong Chhnang province and randomly assigned to receive 12 wk of iron (60 mg; Fe group), MMNs (14 other micronutrients; MMN group), iron plus MMNs (Fe+MMN group), or placebo capsules. A 2 × 2 factorial intention-to-treat analysis with the use of a generalized mixed-effects model was used to assess the effects of iron and MMNs and the interaction between these factors. Results: In July 2015, 809 women were recruited and 760 (94%) completed the trial. Baseline anemia prevalence was 58% (venous blood). Mean (95% CI) hemoglobin concentrations at 12 wk in the Fe, MMN, Fe+MMN, and placebo groups were 121 (120, 121), 116 (116, 117), 123 (122, 123), and 116 (116, 117) g/L, with no iron × MMN interaction ( P = 0.66). Mean (95% CI) increases in hemoglobin were 5.6 g/L (3.8, 7.4 g/L) ( P < 0.001) among women who received iron ( n = 407) and 1.2 g/L (-0.6, 3.0 g/L) ( P = 0.18) among women who received MMNs ( n = 407). The predicted proportions (95% CIs) of women with a hemoglobin response (≥10 g/L at 12 wk) were 19% (14%, 24%), 9% (5%, 12%), 30% (24%, 35%), and 5% (2%, 9%) in the Fe, MMN, Fe+MMN, and placebo groups, respectively. Conclusions: Daily iron supplementation for 12 wk increased hemoglobin in nonpregnant Cambodian women; however, MMNs did not confer additional significant benefit. Overall, ∼24% of women who received iron responded after 12 wk; even fewer would be

  18. Impact of hemoglobin on plasma pro-B-type natriuretic peptide concentrations in the general population

    DEFF Research Database (Denmark)

    Nybo, Mads; Benn, Marianne; Mogelvang, Rasmus

    2007-01-01

    , the impact of hemoglobin status on proBNP concentrations has not been established in the general population. METHODS: In the 4th examination in the Copenhagen City Heart Study, we performed a nested case-control study of 6238 individuals from a Danish general population. Of these, 3497 randomly selected...... participants also underwent an echocardiographic examination. The population was stratified into groups depending on health and hemoglobin status. Correlations between hemoglobin and proBNP concentrations were examined by simple and multiple regression analyses, adjusted for variables known to influence...... the proBNP plasma concentration. RESULTS: The mean proBNP concentration was increased 1.7-fold in the group with anemia vs the nonanemic group [mean (SD) 42 (45) pmol/L vs 25 (29) pmol/L, P hemoglobin on pro...

  19. Lower versus Higher Hemoglobin Threshold for Transfusion in Septic Shock

    DEFF Research Database (Denmark)

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn

    2014-01-01

    BACKGROUND: Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. METHODS: In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care...... unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay...... were similar in the two intervention groups. CONCLUSIONS: Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion...

  20. Blood Test: Hemoglobin A1C

    Science.gov (United States)

    ... Why Are Hemoglobin A1c Tests Done? When a child has diabetes, hemoglobin A1c levels are followed to see how well medicines are working. If a child with diabetes has a high hemoglobin A1c level, it may ...

  1. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting.

    Science.gov (United States)

    Nkrumah, Bernard; Nguah, Samuel Blay; Sarpong, Nimako; Dekker, Denise; Idriss, Ali; May, Juergen; Adu-Sarkodie, Yaw

    2011-04-21

    In resource poor settings where automated hematology analyzers are not available, the Cyanmethemoglobin method is often used. This method though cheaper, takes more time. In blood donations, the semi-quantitative gravimetric copper sulfate method which is very easy and inexpensive may be used but does not provide an acceptable degree of accuracy. The HemoCue® hemoglobin photometer has been used for these purposes. This study was conducted to generate data to support or refute its use as a point-of-care device for hemoglobin estimation in mobile blood donations and critical care areas in health facilities. EDTA blood was collected from study participants drawn from five groups: pre-school children, school children, pregnant women, non-pregnant women and men. Blood collected was immediately processed to estimate the hemoglobin concentration using three different methods (HemoCue®, Sysmex KX21N and Cyanmethemoglobin). Agreement between the test methods was assessed by the method of Bland and Altman. The Intraclass correlation coefficient (ICC) was used to determine the within subject variability of measured hemoglobin. Of 398 subjects, 42% were males with the overall mean age being 19.4 years. The overall mean hemoglobin as estimated by each method was 10.4 g/dl for HemoCue, 10.3 g/dl for Sysmex KX21N and 10.3 g/dl for Cyanmethemoglobin. Pairwise analysis revealed that the hemoglobin determined by the HemoCue method was higher than that measured by the KX21N and Cyanmethemoglobin. Comparing the hemoglobin determined by the HemoCue to Cyanmethemoglobin, the concordance correlation coefficient was 0.995 (95% CI: 0.994-0.996, p < 0.001). The Bland and Altman's limit of agreement was -0.389 - 0.644 g/dl with the mean difference being 0.127 (95% CI: 0.102-0.153) and a non-significant difference in variability between the two measurements (p = 0.843). After adjusting to assess the effect of other possible confounders such as sex, age and category of person, there was no

  2. Randomized controlled trial assessing the efficacy of a reusable fish-shaped iron ingot to increase hemoglobin concentration in anemic, rural Cambodian women.

    Science.gov (United States)

    Rappaport, Aviva I; Whitfield, Kyly C; Chapman, Gwen E; Yada, Rickey Y; Kheang, Khin Meng; Louise, Jennie; Summerlee, Alastair J; Armstrong, Gavin R; Green, Timothy J

    2017-08-01

    Background: Anemia affects 45% of women of childbearing age in Cambodia. Iron supplementation is recommended in populations in which anemia prevalence is high. However, there are issues of cost, distribution, and adherence. A potential alternative is a reusable fish-shaped iron ingot, which, when added to the cooking pot, leaches iron into the fluid in which it is prepared. Objective: We sought to determine whether there was a difference in hemoglobin concentrations in rural Cambodian anemic women (aged 18-49 y) who cooked with the iron ingot or consumed a daily iron supplement compared with a control after 1 y. Design: In Preah Vihear, 340 women with mild or moderate anemia were randomly assigned to 1 ) an iron-ingot group, 2 ) an iron-supplement (18 mg/d) group, or 3 ) a nonplacebo control group. A venous blood sample was taken at baseline and at 6 and 12 mo. Blood was analyzed for hemoglobin, serum ferritin, and serum transferrin receptor. Hemoglobin electrophoresis was used to detect structural hemoglobin variants. Results: Anemia prevalence was 44% with the use of a portable hemoglobinometer during screening. At baseline, prevalence of iron deficiency was 9% on the basis of a low serum ferritin concentration. There was no significant difference in mean hemoglobin concentrations between the iron-ingot group (115 g/L; 95% CI: 113, 118 g/L; P = 0.850) or iron-supplement group (115 g/L; 95% CI: 113, 117 g/L; P = 0.998) compared with the control group (115 g/L; 95% CI: 113, 117 g/L) at 12 mo. Serum ferritin was significantly higher in the iron-supplement group (73 μg/L; 95% CI: 64, 82 μg/L; P = 0.002) than in the control group at 6 mo; however, this significance was not maintained at 12 mo (73 μg/L; 95% CI: 58, 91 μg/L; P = 0.176). Conclusions: Neither the iron ingot nor iron supplements increased hemoglobin concentrations in this population at 6 or 12 mo. We do not recommend the use of the fish-shaped iron ingot in Cambodia or in countries where the prevalence

  3. Substitution of Fingertip Blood for Venous Blood in the Measurement of Hematocrit and Hemoglobin Following Exercise

    Science.gov (United States)

    Fahey, Thomas D.; And Others

    1977-01-01

    Results from comparative testing indicate that fingertip blood is a valid indicator of antecubital venous hematocrit (hct) and hemoglobin (hgb), and that hct ratios determined on the Coulter counter are comparable to those found by the microhematocrit method. (MB)

  4. Hemopressins and other hemoglobin-derived peptides in mouse brain: Comparison between brain, blood, and heart peptidome and regulation in Cpefat/fat mice

    Science.gov (United States)

    Gelman, Julia S.; Sironi, Juan; Castro, Leandro M.; Ferro, Emer S.; Fricker, Lloyd D.

    2010-01-01

    Many hemoglobin-derived peptides are present in mouse brain, and several of these have bioactive properties including the hemopressins, a related series of peptides that bind to cannabinoid CB1 receptors. Although hemoglobin is a major component of red blood cells, it is also present in neurons and glia. To examine whether the hemoglobin-derived peptides in brain are similar to those present in blood and heart, we used a peptidomics approach involving mass spectrometry. Many hemoglobin-derived peptides are found only in brain and not in blood, whereas all hemoglobin-derived peptides found in heart were also seen in blood. Thus, it is likely that the majority of the hemoglobin-derived peptides detected in brain are produced from brain hemoglobin and not erythrocytes. We also examined if the hemopressins and other major hemoglobin-derived peptides were regulated in the Cpefat/fat mouse; previously these mice were reported to have elevated levels of several hemoglobin-derived peptides. Many, but not all of the hemoglobin-derived peptides were elevated in several brain regions of the Cpefat/fat mouse. Taken together, these findings suggest that the post-translational processing of alpha and beta hemoglobin into the hemopressins, as well as other peptides, is upregulated in some but not all Cpefat/fat mouse brain regions. PMID:20202081

  5. Point-of-care hemoglobin testing for postmortem diagnosis of anemia.

    Science.gov (United States)

    Na, Joo-Young; Park, Ji Hye; Choi, Byung Ha; Kim, Hyung-Seok; Park, Jong-Tae

    2018-03-01

    An autopsy involves examination of a body using invasive methods such as dissection, and includes various tests using samples procured during dissection. During medicolegal autopsies, the blood carboxyhemoglobin concentration is commonly measured using the AVOXimeter® 4000 as a point-of-care test. When evaluating the body following hypovolemic shock, characteristics such as reduced livor mortis or an anemic appearance of the viscera can be identified, but these observations arequite subjective. Thus, a more objective test is required for the postmortem diagnosis of anemia. In the present study, the AVOXimeter® 4000 was used to investigate the utility of point-of-care hemoglobin testing. Hemoglobin tests were performed in 93 autopsy cases. The AVOXimeter® 4000 and the BC-2800 Auto Hematology Analyzer were used to test identical samples in 29 of these cases. The results of hemoglobin tests performed with these two devices were statistically similar (r = 0.969). The results of hemoglobin tests using postmortem blood were compared with antemortem test results from medical records from 31 cases, and these results were similar. In 13 of 17 cases of death from internal hemorrhage, hemoglobin levels were lower in the cardiac blood than in blood from the affected body cavity, likely due to compensatory changes induced by antemortem hemorrhage. It is concluded that blood hemoglobin testing may be useful as a point-of-care test for diagnosing postmortem anemia.

  6. Analysis of bias in measurements of potassium, sodium and hemoglobin by an emergency department-based blood gas analyzer relative to hospital laboratory autoanalyzer results.

    Directory of Open Access Journals (Sweden)

    Jian Bo Zhang

    Full Text Available The emergency departments (EDs of Chinese hospitals are gradually being equipped with blood gas machines. These machines, along with the measurement of biochemical markers by the hospital laboratory, facilitate the care of patients with severe conditions who present to the ED. However, discrepancies have been noted between the Arterial Blood Gas (ABG analyzers in the ED and the hospital laboratory autoanalyzer in relation to electrolyte and hemoglobin measurements. The present study was performed to determine whether the ABG and laboratory measurements of potassium, sodium, and hemoglobin levels are equivalent, and whether ABG analyzer results can be used to guide clinical care before the laboratory results become available.Study power analyses revealed that 200 consecutive patients who presented to our ED would allow this prospective single-center cohort study to detect significant differences between ABG- and laboratory-measured potassium, sodium, and hemoglobin levels. Paired arterial and venous blood samples were collected within 30 minutes. Arterial blood samples were measured in the ED by an ABL 90 FLEX blood gas analyzer. The biochemistry and blood cell counts of the venous samples were measured in the hospital laboratory. The potassium, sodium, and hemoglobin concentrations obtained by both methods were compared by using paired Student's t-test, Spearman's correlation, Bland-Altman plots, and Deming regression.The mean ABG and laboratory potassium values were 3.77±0.44 and 4.2±0.55, respectively (P<0.0001. The mean ABG and laboratory sodium values were 137.89±5.44 and 140.93±5.50, respectively (P<0.0001. The mean ABG and laboratory Hemoglobin values were 12.28±2.62 and 12.35±2.60, respectively (P = 0.24.Although there are the statistical difference and acceptable biases between ABG- and laboratory-measured potassium and sodium, the biases do not exceed USCLIA-determined limits. In parallel, there are no statistical differences and

  7. Evaluation of three methods for hemoglobin measurement in a blood donor setting

    Directory of Open Access Journals (Sweden)

    Jacob Rosenblit

    1999-05-01

    Full Text Available CONTEXT: The hemoglobin (Hb level is the most-used parameter for screening blood donors for the presence of anemia, one of the most-used methods for measuring Hb levels is based on photometric detection of cyanmetahemoglobin, as an alternative to this technology, HemoCue has developed a photometric method based on the determination of azide metahemoglobin. OBJECTIVE: To evaluate the performance of three methods for hemoglobin (Hb determination in a blood bank setting. DESIGN: Prospective study utilizing blood samples to compare methods for Hb determination. SETTING: Hemotherapy Service of the Hospital Israelita Albert Einstein, a private institution in the tertiary health care system. SAMPLE: Serial blood samples were collected from 259 individuals during the period from March to June 1996. MAIN MEASUREMENTS: Test performances and their comparisons were assessed by the analysis of coefficients of variation (CV, linear regression and mean differences. RESULTS: The CV for the three methods were: Coulter 0.68%, Cobas 0.82% and HemoCue 0.69%. There was no difference between the mean Hb determination for the three methods (p>0.05. The Coulter and Cobas methods showed the best agreement and the HemoCue method gave a lower Hb determination when compared to both the Coulter and Cobas methods. However, pairs of methods involving the HemoCue seem to have narrower limits of agreement (± 0.78 and ± 1.02 than the Coulter and Cobas combination (± 1.13. CONCLUSION: The three methods provide good agreement for hemoglobin determination.

  8. A comparison of blood nitric oxide metabolites and hemoglobin functional properties among diving mammals.

    Science.gov (United States)

    Fago, Angela; Parraga, Daniel Garcia; Petersen, Elin E; Kristensen, Niels; Giouri, Lea; Jensen, Frank B

    2017-03-01

    The ability of marine mammals to hunt prey at depth is known to rely on enhanced oxygen stores and on selective distribution of blood flow, but the molecular mechanisms regulating blood flow and oxygen transport remain unresolved. To investigate the molecular mechanisms that may be important in regulating blood flow, we measured concentration of nitrite and S-nitrosothiols (SNO), two metabolites of the vasodilator nitric oxide (NO), in the blood of 5 species of marine mammals differing in their dive duration: bottlenose dolphin, South American sea lion, harbor seal, walrus and beluga whale. We also examined oxygen affinity, sensitivity to 2,3-diphosphoglycerate (DPG) and nitrite reductase activity of the hemoglobin (Hb) to search for possible adaptive variations in these functional properties. We found levels of plasma and red blood cells nitrite similar to those reported for terrestrial mammals, but unusually high concentrations of red blood cell SNO in bottlenose dolphin, walrus and beluga whale, suggesting enhanced SNO-dependent signaling in these species. Purified Hbs showed similar functional properties in terms of oxygen affinity and sensitivity to DPG, indicating that reported large variations in blood oxygen affinity among diving mammals likely derive from phenotypic variations in red blood cell DPG levels. The nitrite reductase activities of the Hbs were overall slightly higher than that of human Hb, with the Hb of beluga whale, capable of longest dives, having the highest activity. Taken together, these results underscore adaptive variations in circulatory NO metabolism in diving mammals but not in the oxygenation properties of the Hb. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Hemoglobin (image)

    Science.gov (United States)

    Hemoglobin is the most important component of red blood cells. It is composed of a protein called ... exchanged for carbon dioxide. Abnormalities of an individual's hemoglobin value can indicate defects in the normal balance ...

  10. Prevalence and determinants of declining versus stable hemoglobin levels in whole blood donors

    NARCIS (Netherlands)

    Nasserinejad, Kazem; van Rosmalen, Joost; van den Hurk, Katja; Baart, Mireille; Hoekstra, Trynke; Rizopoulos, Dimitris; Lesaffre, Emmanuel; de Kort, Wim

    2015-01-01

    A too short recovery time after blood donation results in a gradual depletion of iron stores and a subsequent decline in hemoglobin (Hb) levels over time. This decline in Hb levels may depend on individual, unobserved characteristics of the donor. We used a data set of 5388 Dutch blood donors from

  11. Transverse water relaxation in whole blood and erythrocytes at 3T, 7T, 9.4T, 11.7T and 16.4T; determination of intracellular hemoglobin and extracellular albumin relaxivities.

    Science.gov (United States)

    Grgac, Ksenija; Li, Wenbo; Huang, Alan; Qin, Qin; van Zijl, Peter C M

    2017-05-01

    Blood is a physiological substance with multiple water compartments, which contain water-binding proteins such as hemoglobin in erythrocytes and albumin in plasma. Knowing the water transverse (R 2 ) relaxation rates from these different blood compartments is a prerequisite for quantifying the blood oxygenation level-dependent (BOLD) effect. Here, we report the Carr-Purcell-Meiboom-Gill (CPMG) based transverse (R 2CPMG ) relaxation rates of water in bovine blood samples circulated in a perfusion system at physiological temperature in order to mimic blood perfusion in humans. R 2CPMG values of blood plasma, lysed packed erythrocytes, lysed plasma/erythrocyte mixtures, and whole blood at 3 T, 7 T, 9.4 T, 11.7 T and 16.4 T were measured as a function of hematocrit or hemoglobin concentration, oxygenation, and CPMG inter-echo spacing (τ cp ). R 2CPMG in lysed cells showed a small τ cp dependence, attributed to the water exchange rate between free and hemoglobin-bound water to be much faster than τ cp . This was contrary to the tangential dependence in whole blood, where a much slower exchange between cells and blood plasma applies. Whole blood data were fitted as a function of τ cp using a general tangential correlation time model applicable for exchange as well as diffusion contributions to R 2CPMG , and the intercept R 20blood at infinitely short τ cp was determined. The R 20blood values at different hematocrit and the R 2CPMG values of lysed erythrocyte/plasma mixtures at different hemoglobin concentration were used to determine the relaxivity of hemoglobin inside the erythrocyte (r 2Hb ) and albumin (r 2Alb ) in plasma. The r 2Hb values obtained from lysed erythrocytes and whole blood were comparable at full oxygenation. However, while r 2Hb determined from lysed cells showed a linear dependence on oxygenation, this dependence became quadratic in whole blood. This possibly suggests an additional relaxation effect inside intact cells, perhaps due to hemoglobin

  12. Hemoglobin concentrations and associated factors in adolescentes from Recife, Brazil

    Directory of Open Access Journals (Sweden)

    Elisângela Barros Soares Mendonça

    2014-10-01

    Full Text Available OBJECTIVE: To estimate the prevalence of anemia and associated factors in adolescents from the city of Recife in Pernambuco state. METHODS: This is a cross-sectional study, involving a random sample of 256 adolescents of both genders, aged 13 to 18, whose hemoglobin concentrations were evaluated, along with their nutritional status and socioeconomic and demographic characteristics. RESULTS: The prevalence of inadequate hemoglobin concentrations was 10.2% [CI95%=6.7-14.5], reaching levels considered as mild anemia (9 g/dL 0.05, nor with socioeconomic or demographic characteristics (p>0.05. CONCLUSION: Although the prevalence of anemia was low and classified as a mild health problem, preventive nutrition education involving the dissemination of healthy eating habits in schools and encouraging the consumption of iron-rich foods are strongly recommended.

  13. Clinical, hematological and genetic data of a cohort of children with hemoglobin SD

    Directory of Open Access Journals (Sweden)

    Paulo do Val Rezende

    Full Text Available ABSTRACT INTRODUCTION: The hemoglobin FSD is very uncommon in newborn screening programs for sickle cell disease. In the program of Minas Gerais, Brazil, the clinical course of children with hemoglobin SD was observed to be heterogeneous. The objective of this study was to estimate the incidence (1999-2012 and to describe the natural history of a cohort of newborns with hemoglobin SD. METHODS: Isoelectric focusing was the primary method used in newborn screening. Polymerase chain reaction-restriction fragment length polymorphism and gene sequencing were used to identify mutant alleles and for haplotyping. Gap-polymerase chain reaction was used to detect alpha-thalassemia. RESULTS: Eleven cases of hemoglobin S/D-Punjab and eight of Hb S-Korle Bu were detected. Other variants with hemoglobin D mobility were not identified. All hemoglobin D-Punjab and hemoglobin Korle Bu alleles were associated with haplotype I. Among the children with hemoglobin S/D-Punjab, there were four with the ßS CAR haplotype, six with the Benin haplotype, and one atypical. Results of laboratory tests for hemoglobin S/D-Punjab and hemoglobin S-Korle Bu were: hemoglobin 8.0 and 12.3 g/dL (p-value <0.001, leukocyte count 13.9 × 109/L and 10.5 × 109/L (p-value = 0.003, reticulocytes 7.5% and 1.0% (p-value <0.001, hemoglobin F concentration 16.1% and 6.9% (p-value = 0.001 and oxygen saturation 91.9% and 97% (p-value = 0.002, respectively. Only hemoglobin S/D-Punjab children had acute pain crises and needed blood transfusions or hydroxyurea. Those with the Benin ßS haplotype had higher total hemoglobin and hemoglobin F concentrations compared to the CAR haplotype. Transcranial Doppler was normal in all children. CONCLUSION: The clinical course and blood cell counts of children with hemoglobin S/D-Punjab were very similar to those of hemoglobin SS children. In contrast, children with hemoglobin S-Korle Bu had clinical course and blood cell counts like children with the sickle

  14. Elevated Hemoglobin A1C Levels Correlate with Blood Glucose Elevation in Diabetic Patients following Local Corticosteroid Injection in the Hand: A Prospective Study.

    Science.gov (United States)

    Kim, Nayoung; Schroeder, Jake; Hoffler, C Edward; Matzon, Jonas L; Lutsky, Kevin F; Beredjiklian, Pedro K

    2015-10-01

    Diabetic patients develop hand conditions that are managed with local corticosteroid injections. Injections can result in a transient elevation in serum glucose in diabetic patients. Hemoglobin A1c is the accepted measure of long-term plasma glucose control in diabetics (levels ≥7 percent reflect poor blood glucose control). The purpose of this study was to assess the relationship between hemoglobin A1c levels and increased blood glucose levels after corticosteroid injections. Twenty-five diabetic patients were evaluated prospectively. One milliliter containing 10 mg of triamcinolone acetonide was used. The most recent hemoglobin A1c level and normal average blood glucose levels were obtained. Glucose levels were obtained from patient recall of their daily blood glucose self- monitoring on the day of the injection. Postinjection blood glucose levels were recorded until levels returned to preinjection baseline. Twenty patients (80 percent) had elevation of their blood glucose level from baseline. No patient had elevated blood glucose levels after 5 days. Patients with hemoglobin A1c levels greater than or equal to 7 percent had a higher blood glucose elevation and maintained this for longer than those who had a lower hemoglobin A1c level. Patients in the higher hemoglobin A1c group also had a higher number of hyperglycemic events. There was a strong or moderate correlation between hemoglobin A1c and elevated blood glucose levels during days 1 to 4. Patients with hemoglobin A1c levels greater than or equal to 7 percent have elevations in blood glucose that are higher and last longer than patients with lower levels. Hemoglobin A1c levels can be used to roughly predict the degree of blood glucose elevation after corticosteroid injections into the hands of diabetic patients.

  15. Whole Blood Donation Affects the Interpretation of Hemoglobin A(1c)

    NARCIS (Netherlands)

    Dijkstra, Angelique; Lenters-Westra, Erna; de Kort, Wim; Bokhorst, Arlinke G.; Bilo, Henk J. G.; Slingerland, Robbert J.; Vos, Michel J.

    2017-01-01

    Introduction Several factors, including changed dynamics of erythrocyte formation and degradation, can influence the degree of hemoglobin A(1c) (HbA(1c)) formation thereby affecting its use in monitoring diabetes. This study determines the influence of whole blood donation on HbA(1c) in both

  16. The Reaction of Oxy Hemoglobin with Nitrite: Mechanism, Antioxidant-Modulated Effect, and Implications for Blood Substitute Evaluation

    Directory of Open Access Journals (Sweden)

    Denisa Hathazi

    2018-02-01

    Full Text Available The autocatalytic reaction between nitrite and the oxy form of globins involves free radicals. For myoglobin (Mb, an initial binding of nitrite to the iron-coordinated oxygen molecule was proposed; the resulting ferrous-peroxynitrate species was not detected, but its decay product, the high-valent ferryl form, was demonstrated in stopped-flow experiments. Reported here are the stopped flow spectra recorded upon mixing oxy Hb (native, as well as chemically-derivatized in the form of several candidates of blood substitutes with a supraphysiological concentration of nitrite. The data may be fitted to a simple kinetic model involving a transient met-aqua form, in contrast to the ferryl detected in the case of Mb in a similar reaction sequence. These data are in line with a previous observation of a transient accumulation of ferryl Hb under auto-catalytic conditions at much lower concentrations of nitrite (Grubina, R. et al. J. Biol. Chem. 2007, 282, 12916. The simple model for fitting the stopped-flow data leaves a small part of the absorbance changes unaccounted for, unless a fourth species is invoked displaying features similar to the oxy and tentatively assigned as ferrous-peroxynitrate. Density functional theory (DFT calculations support this latter assignment. The reaction allows for differentiating between the reactivities of various chemically modified hemoglobins, including candidates for blood substitutes. Polymerization of hemoglobin slows the nitrite-induced oxidation, in sharp contrast to oxidative-stress type reactions which are generally accelerated, not inhibited. Sheep hemoglobin is found to be distinctly more resistant to reaction with nitrite compared to bovine Hb, at large nitrite concentrations (stopped-flow experiments directly observing the oxy + nitrite reaction as well as under auto-catalytic conditions. Copolymerization of Hb with bovine serum albumin (BSA using glutaraldehyde leads to a distinct increase of the lag time

  17. Hair cortisol concentration and glycated hemoglobin in African American adults.

    Science.gov (United States)

    Lehrer, H Matthew; Dubois, Susan K; Maslowsky, Julie; Laudenslager, Mark L; Steinhardt, Mary A

    2016-10-01

    African Americans have higher diabetes prevalence compared to Whites. They also have elevated cortisol levels - indicating possible HPA axis dysregulation - which may raise blood glucose as part of the biological response to physiological and psychosocial stress. Little is known about chronic cortisol levels in African Americans, and even less about the role of chronically elevated cortisol in type 2 diabetes development in this racial group. We used analysis of cortisol in hair to examine associations of long-term (∼3months) cortisol levels with glycated hemoglobin (HbA1c) in a group of African American adults. In exploratory analyses, we also studied the relationship of hair dehydroepiandrosterone (DHEA) with HbA1c. Participants were 61 community-dwelling African American adults (85% female; mean age 54.30 years). The first 3cm of scalp-near hair were analyzed for cortisol and DHEA concentration using enzyme-linked immunoassay analysis. Glycated hemoglobin was assessed, and regression analyses predicting HbA1c from hair cortisol and DHEA were performed in the full sample and in a subsample of participants (n=20) meeting the National Institute of Diabetes and Digestive Kidney Disease (NIDDK) criteria for type 2 diabetes (HbA1c≥6.5%). In the full sample, HbA1c increased with hair cortisol level (β=0.22, p=0.04, f(2)=0.10), independent of age, sex, chronic health conditions, diabetes medication use, exercise, and depressive symptoms. In the subsample of participants with an HbA1c≥6.5%, hair cortisol was also positively related to HbA1c (β=0.45, p=0.04, f(2)=0.32), independent of diabetes medication use. Glycated hemoglobin was unrelated to hair DHEA in both the full sample and HbA1c≥6.5% subsample. Long-term HPA axis dysregulation in the form of elevated hair cortisol is associated with elevated HbA1c in African American adults. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. The relationship between extent of hemoglobin purification and the performance characteristics of a blood-based flocculant

    Science.gov (United States)

    Whole blood is a highly complex substance. Hemoglobin, the most abundant blood protein, can function as a flocculant of colloidal clay; most of the other blood components exhibit poor flocculant activity. For the purpose of processing raw whole blood into a flocculant product, the practical value of...

  19. Validated hemoglobin-depletion approach for red blood cell lysate proteome analysis by means of 2D PAGE and Orbitrap MS.

    Science.gov (United States)

    Walpurgis, Katja; Kohler, Maxie; Thomas, Andreas; Wenzel, Folker; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario

    2012-08-01

    The analysis of the cytosolic red blood cell (RBC) proteome is negatively affected by the high intracellular amount of hemoglobin complicating the detection of low-abundant cytosolic proteins. In this study, an alternative approach for the preparation of hemoglobin-depleted RBC lysates is presented, which was established in combination with downstream 2D PAGE analysis and Orbitrap MS. Hemoglobin removal was accomplished by using HemoVoid(TM) depletion reagent, which enabled a very efficient enrichment of low-abundant proteins by simultaneously reducing the hemoglobin concentration of the sample. After defining selected sample preparation protocol characteristics including specificity/selectivity, precision and linearity, a 2D reference map (pH 4-7) of the cytosolic RBC proteome was generated and a total of 189 different proteins were identified. Thus, the presented approach proved to be highly suitable to prepare reproducible high-resolution 2D protein maps of the RBC cytosol and provides a helpful tool for future studies investigating disease- or storage-induced changes of the cytosolic RBC proteome. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Outcome analysis of hemoglobin A1c, weight, and blood pressure in a VA diabetes education program.

    Science.gov (United States)

    North, Susan L; Palmer, Glen A

    2015-01-01

    To determine the effect of a specific diabetes education class (Basics) on hemoglobin A1c values, weight, and systolic blood pressure. In this retrospective study, the researchers compared 2 groups of male veterans with a recent diagnosis of type 2 diabetes. One group received diabetes group education (n = 175) over a 4-month period, and the other received standard diabetes management follow-up (n = 184). Outpatient clinic setting in the Midwest. Basics class compared with standard level of care. Pre- and post-laboratory values for hemoglobin A1c, weight, and systolic blood pressure. Multivariate analysis of covariance and follow-up univariate statistics for significant differences. Findings revealed significant differences in hemoglobin A1c (P education curriculum and reduction of hemoglobin A1c values. Some participants also had added benefit of significant weight loss. Published by Elsevier Inc.

  1. Correlation of maternal factors and hemoglobin concentration during pregnancy Shiraz 2006

    Directory of Open Access Journals (Sweden)

    Marzieh Akbarzadeh

    2009-12-01

    Full Text Available Background: Anemia in pregnancy is a serious condition, contributing to maternal mortality, morbidity and fetal morbidity and its prevalence varies between 35-100% in developing countries. This investigation is conducted to survey the correlation of maternal factors and the changes in hemoglobin in pregnant women. Method: In this study, 108 healthy pregnant women with gestational age of 10 to 14 weeks, chosen by cluster random sampling were included. The women were followed in three visits: at the end of the first, second and third trimester. In addition, correlation of Hb concentration with maternal factors including BMI, age parity, hyperemesis, gestational age, pregnancy interval and weight gain was investigated. Results: There was no significant correlation between BMI, parity, pregnancy interval, severe nausea and vomiting and also maternal age with hemoglobin level during pregnancy. Moreover, Multiple regression models showed that adequate maternal weight gain (P<0.009 and high hemoglobin (p<0.0001 in the first trimester were positive predictors and late iron supplementation was negative predictor of hemoglobin in pregnancy (P<0.006. Conclusion: Our data demonstrated that adequate maternal weight gain, high hemoglobin in the first trimester and also late iron supplementation could be as predictors in clinical settings in this query.

  2. Effects of laser acupoint irradiation on blood glucose and glycosylated hemoglobin in type 2 diabetes mellitus

    Science.gov (United States)

    Hui-Hui, Liu; Guo-Xin, Xiong; Li-Ping, Zhang

    2016-06-01

    To investigate the effects of semiconductor laser acupoint irradiation on blood glucose, glycosylated hemoglobin and physical fitness in type 2 diabetes mellitus, 44 cases of type 2 diabetic patients were randomly divided into a control group and a treatment group. All patients in both groups were given a drug treatment. The Hegu, Quchi and Zusanli acupoints of patients in the treatment group were then irradiated daily for 15 d with a 10 MW semiconductor laser. Before and after treatment, patients in both groups underwent a variety of tests and measurements: a two-hour postprandial blood glucose test; a glycosylated hemoglobin test and body mass index (BMI), waist-to-hip ratio (WHR) and body fat percentage (BFP) measurements. The data detected after treatment greatly decreased in the treatment group and was significantly different from that in the control group. It is shown that the acupoint irradiation with a semiconductor laser can improve two-hour postprandial blood glucose, glycosylated hemoglobin and some physical fitness measurements in type 2 diabetes mellitus patients.

  3. Non-invasive method to detect the changes of glucose concentration in whole blood using photometric technique.

    Science.gov (United States)

    Rajan, Shiny Amala Priya; Towe, Bruce C

    2014-01-01

    A non-invasive method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm, which is a peak absorbance of hemoglobin. As the glucose concentration in blood decreases, its osmolarity also decreases and the Red Blood Cells (RBCs) swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds.

  4. Effect of hemolysis and free hemoglobin on optical hematocrit measurements in the extracorporeal circulation.

    Science.gov (United States)

    Paluszkiewicz, Aleksandra; Kellner, Josef; Elshehabi, Morad; Schneditz, Daniel

    2008-01-01

    Clinically significant hemolysis is a rare but serious problem in dialysis. Because hemolysis affects red blood cell count and optical density of plasma it has been speculated whether techniques used for online blood volume monitoring would be useful to detect hemolysis. In this study the influence of free hemoglobin on hematocrit and relative blood volume changes measured by optical means (CritLine, HemaMetrics, Kaysville, UT) were examined using an in vitro model with bovine blood. Free hemoglobin solutions were added in steps to circulating whole blood at baseline hematocrits covering a range from 30% to 60% and at blood flows of approximately 200 and 400 ml/min. The free hemoglobin concentration reached was in the range of 2 to 3 g/dl. The presence of free hemoglobin led to a relative increase in hematocrit in the range of 0.3% per 0.1 g of free hemoglobin per dl (+3% dl/g). As an increase in hematocrit is interpreted as a decrease in blood volume, this change referred to an apparent decrease in relative blood volume in the same order of magnitude (-3% dl/g). Effects were more pronounced at low baseline hematocrit. Thus, although optical hematocrit readings are affected by the presence of free hemoglobin the changes at levels associated with clinical symptoms appear to be too small to be accurately detected in the in vivo situation where the hematocrit and the resulting optical signal is affected by various physiological processes and therefore much noisier.

  5. Determination of Human Hemoglobin Derivatives.

    Science.gov (United States)

    Attia, Atef M M; Ibrahim, Fatma A A; Abd El-Latif, Noha A; Aziz, Samir W; Abdelmottaleb Moussa, Sherif A; Elalfy, Mohsen S

    2015-01-01

    The levels of the inactive hemoglobin (Hb) pigments [such as methemoglobin (metHb), carboxyhemoglobin (HbCO) and sulfohemoglobin (SHb)] and the active Hb [in the oxyhemoglobin (oxyHb) form] as well as the blood Hb concentration in healthy non pregnant female volunteers were determined using a newly developed multi-component spectrophotometric method. The results of this method revealed values of SHb% in the range (0.0727-0.370%), metHb% (0.43-1.0%), HbCO% (0.4-1.52%) and oxyHb% (97.06-98.62%). Furthermore, the results of this method revealed values of blood Hb concentration in the range (12.608-15.777 g/dL). The method is highly sensitive, accurate and reproducible.

  6. National Trends in Hemoglobin Concentration and Prevalence of Anemia among Chinese School-Aged Children, 1995-2010.

    Science.gov (United States)

    Song, Yi; Wang, Hai-Jun; Dong, Bin; Wang, Zhiqiang; Ma, Jun; Agardh, Anette

    2017-04-01

    To assess the trend of sex disparity in hemoglobin concentration and prevalence of anemia among Chinese school-aged children from 1995 to 2010. Data were collected from 360 866 children aged 7, 9, 12, 14, and 17 years during 4 cross-sectional surveys (1995, 2000, 2005, and 2010) of the Chinese National Surveys on Students Constitution and Health. Shifts in hemoglobin concentration distributions were compared by sex. Average shifts and sex differences were calculated with quantile regression models. Logistic regression was used to estimate the prevalence odds ratio of sex for prevalence of anemia in different surveys. The mean hemoglobin concentration increased among Chinese children between 1995 and 2010, from 132.7 to 138.3 g/L in boys, and from 127.7 to 132.3 g/L in girls. The prevalence of anemia decreased from 18.8% in 1995 to 9.9% in 2010. It was higher in rural than urban children among all age groups. The prevalence odds ratios of girls versus boys for anemia increased in both urban and rural areas over time. Hemoglobin concentration and prevalence of anemia improved among Chinese school-aged children over time. Hemoglobin concentration improved faster in boys than girls and as a result the relative prevalence of anemia in girls compared with boys increased. Sex-specific preventive guidelines and public health policies for childhood anemia are needed in China. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  8. Autologous blood sequestration using a double venous reservoir bypass circuit and polymerized hemoglobin prime.

    Science.gov (United States)

    Neragi-Miandoab, Siyamek; Guerrero, J Luis; Vlahakes, Gus J

    2002-01-01

    Cardiac surgery often necessitates transfusion of homologous blood. Hemoglobin based oxygen carrying solutions (HBOCs) transport oxygen, suggesting use in cardiopulmonary bypass. HBOC was used in a novel oxygenator double-reservoir circuit that permits acute sequestration of a portion of the autologous blood volume during bypass. Two groups of seven mongrel dogs each were studied in an experimental bypass model using global myocardial ischemia and cardioplegia protection: HBOC group, initial venous return drained to a separate reservoir and hypothermic bypass was conducted with HBOC containing perfusate in a second bypass reservoir; Control group, crystalloid prime in a conventional circuit. Hemodynamics and metabolic and hematologic parameters were measured before and 60 min after aortic clamp removal and reinfusion of sequestered autologous blood. Blood gases, base excess, hematocrit, total hemoglobin, and platelet counts were measured. In the HBOC group, metabolic acidosis did not occur, and ventricular function was preserved. Net conservation of platelets was noted at study conclusion: control 33+/-13 x 10(3) per mm3 versus HBOC 48+/-13 x 10(3), p conservation of the platelet mass occurs, a portion of which is not exposed to the deleterious effects of hypothermia and cardiopulmonary bypass.

  9. In vitro adduct formation of phosgene with albumin and hemoglobin in human blood

    NARCIS (Netherlands)

    Noort, D.; Hulst, A.G.; Fidder, A.; Gurp, R.A. van; Jong, L.P.A. de; Benschop, H.P.

    2000-01-01

    The development of procedures for retrospective detection and quantitation of exposure to phosgene, based on adducts to hemoglobin and albumin, is described. Upon incubation of human blood with [14C]phosgene (0-750 μM), a significant part of radioactivity (0-13%) became associated with globin and

  10. Effects of iron supplementation on red blood cell hemoglobin content in pregnancy

    Directory of Open Access Journals (Sweden)

    Margreet Schoorl

    2012-11-01

    Full Text Available Although a mild degree of anemia is common in the third trimester of pregnancy, it remains a challenge to establish whether a decrease in hemoglobin (Hb concentration is physiological or pathological. The World Health Organization suggested a Hb concentration of 110 g/L to discriminate anemia. Several European investigators recommended Hb cut-off values of between 101-110 g/L. The aim of this study was to establish short-term effects of iron supplementation on the hemoglobin content of reticulocytes (Ret-He and red blood cells (RBC-He in case of suspected iron deficient erythropoiesis (IDE in the third trimester of pregnancy. Twenty-five subjects with suspected IDE during pregnancy (Hb ≤110g/L, Ret-He <29.6 pg, zinc protoporphyrin >75 mol/mol hem participated in the study. After iron supplementation, reticulocyte counts increased from 0.061±0.015x1012/L to 0.079±0.026x1012/L and Ret-He increased from 23.6±2.8 pg to 28.3±2.6 pg (P=<0.001. RBC-He increased from 26.9±1.9 pg to 27.4±1.8 pg (not significant, NS and Ret-He/RBC-He ratio increased from 0.97±0.06 towards 1.07±0.05 (P=<0.001. Hb concentrations demonstrated an obvious increase from 105±6 g/L towards 115±5 g/L (P≤0.001 after supplementation. An obvious increase in RBC distribution width was observed from 45.0±3.6 fL towards 52.3±7.0 fL (P≤0.001. We recommend that Ret-He and Ret-He/RBC-He ratio be integrated into the protocols for anemia screening and for monitoring effects of iron supplementation during pregnancy. In particular, the parameters should be considered in subjects with Hb results in the controversial range of 101-108 g/L.

  11. Prevalence and determinants of declining versus stable hemoglobin levels in whole blood donors

    NARCIS (Netherlands)

    Nasserinejad, K.; van Rosmalen, J.; van den Hurk, K.; Baart, M.; Hoekstra, T.; Rizopoulos, D.; Lesaffre, E.; Kort, W.

    2015-01-01

    Background A too short recovery time after blood donation Results in a gradual depletion of iron stores and a subsequent decline in hemoglobin (Hb) levels over time. This decline in Hb levels may depend on individual, unobserved characteristics of the donor. Study Design and Methods We used a data

  12. Spectral filtering modulation method for estimation of hemoglobin concentration and oxygenation based on a single fluorescence emission spectrum in tissue phantoms.

    Science.gov (United States)

    Liu, Quan; Vo-Dinh, Tuan

    2009-10-01

    Hemoglobin concentration and oxygenation in tissue are important biomarkers that are useful in both research and clinical diagnostics of a wide variety of diseases such as cancer. The authors aim to develop simple ratiometric method based on the spectral filtering modulation (SFM) of fluorescence spectra to estimate the total hemoglobin concentration and oxygenation in tissue using only a single fluorescence emission spectrum, which will eliminate the need of diffuse reflectance measurements and prolonged data processing as required by most current methods, thus enabling rapid clinical measurements. The proposed method consists of two steps. In the first step, the total hemoglobin concentration is determined by comparing a ratio of fluorescence intensities at two emission wavelengths to a calibration curve. The second step is to estimate oxygen saturation by comparing a double ratio that involves three emission wavelengths to another calibration curve that is a function of oxygen saturation for known total hemoglobin concentration. Theoretical derivation shows that the ratio in the first step is linearly proportional to the total hemoglobin concentrations and the double ratio in the second step is related to both total hemoglobin concentration and hemoglobin oxygenation for the chosen fiber-optic probe geometry. Experiments on synthetic fluorescent tissue phantoms, which included hemoglobin with both constant and varying oxygenation as the absorber, polystyrene spheres as scatterers, and flavin adenine dinucleotide as the fluorophore, were carried out to validate the theoretical prediction. Tissue phantom experiments confirm that the ratio in the first step is linearly proportional to the total hemoglobin concentration and the double ratio in the second step is related to both total hemoglobin concentrations and hemoglobin oxygenation. Furthermore, the relations between the two ratios and the total hemoglobin concentration and hemoglobin oxygenation are insensitive

  13. Study on the relationship between blood levels of growth hormone, glycosylated hemoglobin and micro-vascular nephropathy in patients with diabetes

    International Nuclear Information System (INIS)

    Cai Facheng; Yao Yingfei; Zhang Jinchi

    2005-01-01

    Objective: To evaluate the relationship between blood levels of growth hormone, glycosylated hemoglobin and micro-vascular nephropathy in patients with diabetes. Methods: Blood growth hormone and β 2 -m levels were determined with RIA and GH2 bA 1C , blood glucose were determined with biochemical method in 41 diabetic patients and 32 controls. Results: The blood levels of growth hormone, glycosylated hemoglobin, β 2 -microglobulin and fasting blood glucose in the patients with diabetes well controlled (n=22) were significantly higher than those in controls and levels in patients with diabetes poorly controlled (n=19) were again significantly higher than those in patients with diabetes well controlled (P 2 -microglobulin and fasting blood glucose is very important for early detection of diabetic nephropathy. (authors)

  14. Hemoglobin, hematocrit, and changes in cerebral blood flow: the Second Manifestations of ARTerial disease-Magnetic Resonance study.

    Science.gov (United States)

    van der Veen, Pieternella H; Muller, Majon; Vincken, Koen L; Westerink, Jan; Mali, Willem P T M; van der Graaf, Yolanda; Geerlings, Mirjam I

    2015-03-01

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease (mean age 57 ± 10 years) with available data on magnetic resonance angiography to measure parenchymal CBF. Mean (SD) parenchymal CBF at baseline was 52.3 (9.8) mL/min/100 mL and decreased with 1.5 (11.0) mL/min/100 mL after on average 3.9 years of follow-up. Linear regression analyses showed that greater hemoglobin and hematocrit values were associated with lower baseline parenchymal CBF and more decline in parenchymal CBF over time, independent of cardiovascular risk factors, use of antiplatelet drugs, anticoagulants, or diuretics, and brain measures: adjusted mean differences (95% confidence interval [CI]) in decline in parenchymal CBF between patients in the lower and upper quartiles of hemoglobin and hematocrit were -2.48 (95% CI -3.70 to -1.25) and -3.69 (95% CI -5.45 to -1.94) mL/min/100 mL. Higher hemoglobin and hematocrit were associated with lower baseline parenchymal CBF and a greater decline in parenchymal CBF over time, possibly as a result of physiological compensating mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Optical noninvasive calculation of hemoglobin components concentrations and fractional oxygen saturation using a ring-scattering pulse oximeter

    Science.gov (United States)

    Abdallah, Omar; Stork, Wilhelm; Muller-Glaser, Klaus

    2004-06-01

    The deficiencies of the currently used pulse oximeter are discussed in diverse literature. A hazardous pitfalls of this method is that the pulse oximeter will not detect carboxyhemoglobin (COHb) and methemoglobin (metHb) concentrations. This leads to incorrect measurement of oxygen saturation by carbon monoxide poisoning and methemoglobinemia. Also the total hemoglobin concentration will not be considered and can only be measured in-vitro up to now. A second pitfall of the standard pulse oximetry is that it will not be able to show a result by low perfusion of tissues. This case is available inter alia when the patient is under shock or has a low blood pressure. The new non-invasive system we designed measures the actual (fractional) oxygen saturation and hemoglobin concentration. It will enable us also to measure COHb and metHb. The measurement can be applied at better perfused body central parts. Four or more light emitting diodes (LEDs) or laser diodes (LDs) and five photodiodes (PDs) are used. The reflected light signal detected by photodiodes is processed using a modified Lambert-Beer law (I=I0×e-α.d ). According to this law, when a non scattering probe is irradiated with light having the incident intensity I0, the intensity of transmitted light I decays exponentially with the absorption coefficient a of that probe and its thickness d. Modifications of this law have been performed following the theoretical developed models in literature, Monte Carlo simulation and experimental measurement.

  16. Imaging the effect of hemoglobin on properties of RBCs using common-path digital holographic microscope

    Science.gov (United States)

    Joglekar, M.; Shah, H.; Trivedi, V.; Mahajan, S.; Chhaniwal, V.; Leitgeb, R.; Javidi, B.; Anand, A.

    2017-07-01

    Adequate supply of oxygen to the body is the most essential requirement. In vertebrate species this function is performed by Hemoglobin contained in red blood cells. The mass concentration of the Hb determines the oxygen carrying capacity of the blood. Thus it becomes necessary to determine its concentration in the blood, which helps in monitoring the health of a person. If the amount of Hb crosses certain range, then it is considered critical. As the Hb constitutes upto 96% of red blood cells dry content, it would be interesting to examine various physical and mechanical parameters of RBCs which depends upon its concentration. Various diseases bring about significant variation in the amount of hemoglobin which may alter certain parameters of the RBC such as surface area, volume, membrane fluctuation etc. The study of the variations of these parameters may be helpful in determining Hb content which will reflect the state of health of a human body leading to disease diagnosis. Any increase or decrease in the amount of Hb will change the density and hence the optical thickness of the RBCs, which affects the cell membrane and thereby changing its mechanical and physical properties. Here we describe the use of lateral shearing digital holographic microscope for quantifying the cell parameters for studying the change in biophysical properties of cells due to variation in hemoglobin concentration.

  17. A comparison of blood nitric oxide metabolites and hemoglobin functional properties among diving mammals

    DEFF Research Database (Denmark)

    Fago, Angela; Parraga, Daniel Garcia; Petersen, Elin E

    2017-01-01

    examined oxygen affinity, sensitivity to 2,3-diphosphoglycerate (DPG) and nitrite reductase activity of the hemoglobin (Hb) to search for possible adaptive variations in these functional properties. We found levels of plasma and red blood cells nitrite similar to those reported for terrestrial mammals...... in blood oxygen affinity among diving mammals likely derive from phenotypic variations in red blood cell DPG levels. The nitrite reductase activities of the Hbs were overall slightly higher than that of human Hb, with the Hb of beluga whale, capable of longest dives, having the highest activity. Taken...

  18. Structure and stability of human hemoglobin microparticles prepared with a double emulsion technique.

    Science.gov (United States)

    Cedrati, N; Bonneaux, F; Labrude, P; Maincent, P

    1997-09-01

    Hemoglobin solutions can be used as blood substitutes but they present some disadvantages often due to their rapid removal from the bloodstream after injection. A possible way of overcoming this problem is to trap hemoglobin inside particles. This study deals with the preparation, structure and stability of poly(lactic acid) and ethylcellulose microparticles containing human hemoglobin obtained with a double emulsion technique. We investigated the manufacturing process of these particles in order to increase the encapsulation ratio of hemoglobin. For this purpose, some parameters involved in the procedure were optimized, such as hemoglobin concentration and duration of stirring: hemoglobin loading increases with its concentration in the preparation and well-defined stirring time avoids a leakage of hemoglobin. Hemoglobin concentration, surfactant concentration i.e. poly(vinylic alcohol), amounts of polymer and solvent (methylene chloride), duration and speed of stirring. The microparticles were prepared with satisfactory yields (60 to 73%). They were spherical and their mean size was lower than 200 microns. The functional properties of entrapped hemoglobin were studied. The encapsulation did not alter hemoglobin and the oxygen affinity of the hemoglobin remained unmodified (P50 about 13.9 mm Hg in a Bis-Tris buffer pH 7.4 at 37 degrees C). Moreover, only low levels of methemoglobin could be detected (less than 3%). Besides, about 90% of encapsulated hemoglobin could be released from microparticles, with a speed related to the internal structure of the particles. The prepared microparticles were stored during one month at +4 degrees C. No degradation of the particle structure occurred and the functional properties of hemoglobin were preserved. These particles could provide a potential source of oxygen in the field of biotechnologies but any application for a transfusional purpose would first require a drastic reduction in particle size.

  19. Solid-Phase Extraction of Hemoglobin from Human Whole Blood with a Coordination-Polymer-Derived Composite Material Based on ZnO and Mesoporous Carbon.

    Science.gov (United States)

    Jia, Yuan; Xu, Xinxin; Ou, Jinzhao; Liu, Xiaoxia

    2017-11-13

    A composite material, ZnO@MC, has been synthesized successfully by calcination using a one-dimensional zinc-based coordination polymer as the precursor. In ZnO@MC, ZnO particles with a size of about 5-8 nm are dispersed evenly in a mesoporous carbon matrix. Adsorption experiments at pH 6.8 with 2 mg ZnO@MC as adsorbent illustrated an adsorption efficiency of 92.3 % in 5 mL hemoglobin (Hb) solution with a concentration of 100 mg L -1 . In contrast, the adsorption of bovine serum albumin can almost be ignored under the same conditions. The selectivity originates from a strong Zn II -histidine interaction between ZnO@MC and hemoglobin. The adsorption behavior of hemoglobin on ZnO@MC fits the Temkin model perfectly with a capacity as high as 11646 mg g -1 . The hemoglobin adsorbed on the composite material can be eluted easily with sodium dodecyl sulfate stripping reagent with an extraction efficiency of 87.7 %. Circular dichroism spectra and protein activity studies suggest the structure and biological activity of hemoglobin is the same before and after the adsorption/desorption experiment. Finally, the ZnO@MC composite material was employed to extract hemoglobin from human whole blood without any pretreatment, and gave a very satisfactory result. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. The Effects of Dietary Iron and Capsaicin on Hemoglobin, Blood Glucose, Insulin Tolerance, Cholesterol, and Triglycerides, in Healthy and Diabetic Wistar Rats.

    Science.gov (United States)

    Márquez-Ibarra, Adriana; Huerta, Miguel; Villalpando-Hernández, Salvador; Ríos-Silva, Mónica; Díaz-Reval, María I; Cruzblanca, Humberto; Mancilla, Evelyn; Trujillo, Xóchitl

    2016-01-01

    Our aim was to assess the effects of dietary iron, and the compound capsaicin, on hemoglobin as well as metabolic indicators including blood glucose, cholesterol, triglycerides, insulin, and glucose tolerance. Our animal model was the Wistar rat, fed a chow diet, with or without experimentally induced diabetes. Diabetic males were fed control, low, or high-iron diets, the latter, with or without capsaicin. Healthy rats were fed identical diets, but without the capsaicin supplement. We then measured the parameters listed above, using the Student t-test and ANOVA, to compare groups. Healthy rats fed a low-iron diet exhibited significantly reduced total cholesterol and triglyceride levels, compared with rats fed a control diet. Significantly reduced blood lipid was also provoked by low dietary iron in diabetic rats, compared with those fed a control diet. Insulin, and glucose tolerance was only improved in healthy rats fed the low-iron diet. Significant increases in total cholesterol were found in diabetic rats fed a high-iron diet, compared with healthy rats fed the same diet, although no statistical differences were found for triglycerides. Hemoglobin levels, which were not statistically different in diabetic versus healthy rats fed the high-iron diet, fell when capsaicin was added. Capsaicin also provoked a fall in the level of cholesterol and triglycerides in diabetic animals, versus diabetics fed with the high iron diet alone. In conclusion, low levels of dietary iron reduced levels of serum triglycerides, hemoglobin, and cholesterol, and significantly improved insulin, and glucose tolerance in healthy rats. In contrast, a high-iron diet increased cholesterol significantly, with no significant changes to triglyceride concentrations. The addition of capsaicin to the high-iron diet (for diabetic rats) further reduced levels of hemoglobin, cholesterol, and triglycerides. These results suggest that capsaicin, may be suitable for the treatment of elevated hemoglobin

  1. A study of membrane protein defects and alpha hemoglobin chains of red blood cells in human beta thalassemia

    International Nuclear Information System (INIS)

    Rouyer-Fessard, P.; Garel, M.C.; Domenget, C.; Guetarni, D.; Bachir, D.; Colonna, P.; Beuzard, Y.

    1989-01-01

    The soluble pool of alpha hemoglobin chains present in blood or bone marrow cells was measured with a new affinity method using a specific probe, beta A hemoglobin chain labeled with [ 3 H]N-ethylmaleimide. This pool of soluble alpha chains was 0.067 ± 0.017% of hemoglobin in blood of normal adult, 0.11 ± 0.03% in heterozygous beta thalassemia and ranged from 0.26 to 1.30% in homozygous beta thalassemia intermedia. This elevated pool of soluble alpha chains observed in human beta thalassemia intermedia decreased 33-fold from a value of 10% of total hemoglobin in bone marrow cells to 0.3% in the most dense red blood cells. The amount of insoluble alpha chains was measured by using the polyacrylamide gel electrophoresis in urea and Triton X-100. In beta thalassemia intermedia the amount of insoluble alpha chains was correlated with the decreased spectrin content of red cell membrane and was associated with a decrease in ankyrin and with other abnormalities of the electrophoretic pattern of membrane proteins. The loss and topology of the reactive thiol groups of membrane proteins was determined by using [ 3 H]N-ethylmaleimide added to membrane ghosts prior to urea and Triton X-100 electrophoresis. Spectrin and ankyrin were the major proteins with the most important decrease of thiol groups

  2. A nanocluster-based fluorescent sensor for sensitive hemoglobin detection.

    Science.gov (United States)

    Yang, Dongqin; Meng, Huijie; Tu, Yifeng; Yan, Jilin

    2017-08-01

    In this report, a fluorescence sensor for sensitive detection of hemoglobin was developed. Gold nanoclusters were first synthesized with bovine serum albumin. It was found that both hydrogen peroxide and hemoglobin could weakly quench the fluorescence from the gold nanoclusters, but when these two were applied onto the nanolcusters simultaneously, a much improved quenching was resulted. This enhancing effect was proved to come from the catalytic generation of hydroxyl radical by hemoglobin. Under an optimized condition, the quenching linearly related to the concentration of hemoglobin in the range of 1-250nM, and a limit of detection as low as 0.36nM could be obtained. This provided a sensitive means for the quantification of Hb. The sensor was then successfully applied for blood analyses with simple sample pretreatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Post-transfusion hemoglobin values and patient blood management

    DEFF Research Database (Denmark)

    Moerman, Jan; Vermeulen, Edith; Van Mullem, Mia

    2018-01-01

    Objectives: The objective of this retrospective study was to evaluate the added value of communicating post-transfusion hemoglobin values to clinicians as a strategy to improve RBC utilization in a 500-bed hospital. Methods: The total number of RBC transfusions, the mean number of RBC units...... transfused per patient, the mean pre- and post-transfusion hemoglobin values, the ratio of patients transfused and the ratio of patients with a post-transfusion hemoglobin > 10.5 g/dL were calculated per service and per department for six months. The data were reported to each service and compared...... with the data of the department as peer group. The impact of this communication strategy was evaluated in the following six months. Results: In the six months pre-intervention, the mean post-transfusion hemoglobin value was 9.2 g/dL. Post-transfusion hemoglobin was > 10.5 g/dL in 13.4% of patients (112...

  4. Analytical determination of specific 4,4'-methylene diphenyl diisocyanate hemoglobin adducts in human blood.

    Science.gov (United States)

    Gries, Wolfgang; Leng, Gabriele

    2013-09-01

    4,4'-Methylene diphenyl diisocyanate (MDI) is one of the most important isocyanates in the industrial production of polyurethane and other MDI-based synthetics. Because of its high reactivity, it is known as a sensitizing agent, caused by protein adducts. Analysis of MDI is routinely done by determination of the nonspecific 4,4'-methylenedianiline as a marker for MDI exposure in urine and blood. Since several publications have reported specific adducts of MDI and albumin or hemoglobin, more information about their existence in humans is necessary. Specific adducts of MDI and hemoglobin were only reported in rats after high-dose MDI inhalation. The aim of this investigation was to detect the hemoglobin adduct 5-isopropyl-3-[4-(4-aminobenzyl)phenyl]hydantoin (ABP-Val-Hyd) in human blood for the first time. We found values up to 5.2 ng ABP-Val-Hyd/g globin (16 pmol/g) in blood samples of workers exposed to MDI. Because there was no information available about possible amounts of this specific MDI marker, the analytical method focused on optimal sensitivity and selectivity. Using gas chromatography-high-resolution mass spectrometry with negative chemical ionization, we achieved a detection limit of 0.02 ng ABP-Val-Hyd/g globin (0.062 pmol/g). The robustness of the method was confirmed by relative standard deviations between 3.0 and 9.8 %. Combined with a linear detection range up to 10 ng ABP-Val-Hyd/g globin (31 pmol/g), the enhanced precision parameter demonstrates that the method described is optimized for screening studies of the human population.

  5. Determination Of Ph Including Hemoglobin Correction

    Science.gov (United States)

    Maynard, John D.; Hendee, Shonn P.; Rohrscheib, Mark R.; Nunez, David; Alam, M. Kathleen; Franke, James E.; Kemeny, Gabor J.

    2005-09-13

    Methods and apparatuses of determining the pH of a sample. A method can comprise determining an infrared spectrum of the sample, and determining the hemoglobin concentration of the sample. The hemoglobin concentration and the infrared spectrum can then be used to determine the pH of the sample. In some embodiments, the hemoglobin concentration can be used to select an model relating infrared spectra to pH that is applicable at the determined hemoglobin concentration. In other embodiments, a model relating hemoglobin concentration and infrared spectra to pH can be used. An apparatus according to the present invention can comprise an illumination system, adapted to supply radiation to a sample; a collection system, adapted to collect radiation expressed from the sample responsive to the incident radiation; and an analysis system, adapted to relate information about the incident radiation, the expressed radiation, and the hemoglobin concentration of the sample to pH.

  6. Comparative study of bedside and laboratory measurements of hemoglobin.

    Science.gov (United States)

    Krenzischek, D A; Tanseco, F V

    1996-11-01

    The purpose of this study was to examine the effects of variations in technique on measurements of hemoglobin level done at the bedside and to compare these results with laboratory measurements of hemoglobin. In accordance with hospital policy, procedure, and protocol, various techniques were used to obtain samples of capillary and venous blood and of blood from arterial and central venous catheters. Levels of hemoglobin were measured at the bedside and in the laboratory, and the results were compared. The Johns Hopkins Hospital adult postanesthesia care unit. A total of 187 blood samples were obtained from 62 adults who had undergone general surgery. Group I comprised 20 subjects with capillary and venous blood samples. Group II comprised 21 subjects with arterial blood samples. Group III comprised 21 subjects with central venous blood samples. The results showed that the amount of blood to be discarded before obtaining samples of arterial and central venous blood need not be any larger than double the dead space of the catheter, and that shaking the blood sample for 10 seconds was sufficient to mix the sample before measurement of hemoglobin levels. Results of bedside and laboratory measurements of hemoglobin level were comparable. Bedside measurement of hemoglobin increases efficiency in patient care, decreases risk of blood-transmitted infection for staff, and decreases cost to the patient. However, the persons who perform the assay must be responsible in adhering to the standard of practice to minimize errors in the measurements.

  7. Study on the relationship between blood levels of glycated hemoglobin (HbA1c) and micro-vascular nephropathy in patients with type 2 diabetes

    International Nuclear Information System (INIS)

    Luo Rong; Li Zhuocheng; Yan Dewen

    2004-01-01

    Objective: To evaluate the relationship between blood levels of glycated hemoglobin and microvascular nephropathy in patients with type diabetes. Methods: Blood Glycosylated hemoglobin levels were determined with affinity chromatography and 24 hour urinary microalbumin (m-Alb), β 2 microglobin (β 2 -m) quantified with RIA in 76 patients and 30 controls. Results: With glycated hemoglobin within normal range, there were no differences between the amounts of patients' urinary protein contents and those in controls (P>0.05). With higher blood glycated hemoglobin levels, significant differences could be observed (P 2 microglobin. Differences among the 24 hour urinary quantities of mAlb and β 2 -m in the three groups of patients (divided according to the HbA1c levels, namely 9.0%) were also significant (P 2 microglobin is very important for early detection of diabetic nephropathy

  8. [Hemogram profile and interest of pre-donation hemoglobin measurement in blood donors in the northwest region of Morocco].

    Science.gov (United States)

    Bakrim, S; Ouarour, A; Jaidann, K; Benajiba, M; Masrar, A

    2018-02-01

    Blood donation in Morocco and more particularly in the northwest region is carried out without prior determination of the pre-donation hemoglobin. In addition, we note the lack of scientific research that reports data on the red blood cells, leukocytes and platelet lines in donated blood at the regional or even national level. To study hemogram profile in blood donors taken from the Northwest region of Morocco in order to provide decision makers of the National Center of Blood Transfusion and Hematology with valid scientific arguments to complete the criteria to donate whole blood, by the hemogram. Prospective study, conducted in 15797 volunteer blood donors (BD) aged between 18 and 60 years, collected during mobile or fixed collections carried out by the Regional Blood Transfusion Center of Tangier and Tetouan from November 2014 to May 2016. The hemogram was performed using a Sysmex KX21N ® and the analysis of the data was done by the software SPSS 20.0. According to the World Health Organization, anemia corresponds to a hemoglobin level less than 12g/dL in women and less than 13g/dL in men. We found that 14.5 % of women (n=1054) and 3.0 % of men (n=245) were anemic and anemia was hypochromic microcytic in 58,66 % of these BD. Analysis of the white line showed leucopenia in 2.05 % of BD and 807 cases of leukocytosis (5.27 % of BD). Platelet study showed thrombocytopenia in 3.97 % of BD and thrombocytosis in 151BD (0.99 % of cases). This study shows the interest of systematic pre-donation hemoglobin measurement and periodic realization of the hemogram among BD in the Northwest region of Morocco. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. [Ischemic Changes in the Electrocardiogram and Circulatory Collapse Accompanied by Severe Anemia Owing to the Delay of Red Blood Cell Concentrate Transfusion in Two Patients with Intraoperative Massive Bleeding].

    Science.gov (United States)

    Horiuchi, Toshinori; Noguchi, Teruo; Kurita, Naoko; Yamaguchi, Ayako; Takeda, Masafumi; Sha, Keiichi; Nagahata, Toshihiro

    2016-01-01

    We present two patients developing intraoperative massive bleeding and showed ischemic changes in the electrocardiogram and circulatory collapse accompanied by severe anemia owing to the delay of red blood cell concentrate transfusion. One patient underwent hepatectomy and the other pancreaticoduodenectomy. Their lowest hemoglobin concentration was around 2 g x dl(-1), and they showed ischemic changes in the electrocardiogram and severe decreases in blood pressure. The former received compatible red blood cell concentrate and the latter received uncrossmatched same blood group red blood cell concentrate immediately, and their electrocardiogram and blood pressure quickly improved. To avoid life-threatening anemia, emergency red blood cell concentrate transfusion including compatible different blood group transfusion should be applied for intraoperative massive bleeding.

  10. A coordination polymer based magnetic adsorbent material for hemoglobin isolation from human whole blood, highly selective and recoverable

    Science.gov (United States)

    Zhang, Xiaoxing; Tan, Jipeng; Xu, Xinxin; Shi, Fanian; Li, Guanglu; Yang, Yiqiao

    2017-09-01

    A composite material has been obtained successfully through the loading of nanoscale coordination polymer on magnetic Fe3O4@SiO2 core-shell particle. In this composite material, coordination polymer nanoparticles distribute uniformly on Fe3O4@SiO2 and these two components are "tied" together firmly with chemical bonds. Adsorption experiments suggest this composite material exhibits very excellent selectivity to hemoglobin. But under the same condition, its adsorption to bovine serum albumin can almost be ignored. This selectivity can be attributed to the existence of hydrophobic interactions between coordination polymer nanoparticle and hemoglobin. For composite material, the hemoglobin adsorption process follows Langmuir model perfectly with high speed. The adsorbed hemoglobin can be eluted easily by sodium dodecyl sulfate stripping reagent with structure and biological activity of hemoglobin keeps well. The composite material was also employed to separate hemoglobin from human whole blood, which receives a very satisfactory result. Furthermore, magnetic measurement reveals ferromagnetic character of this composite material with magnetization saturation 3.56 emu g-1 and this guarantees its excellent magnetic separation performance from the treated solution.

  11. U-shaped curve for risk associated with maternal hemoglobin, iron status, or iron supplementation.

    Science.gov (United States)

    Dewey, Kathryn G; Oaks, Brietta M

    2017-12-01

    Both iron deficiency (ID) and excess can lead to impaired health status. There is substantial evidence of a U-shaped curve between the risk of adverse birth outcomes and maternal hemoglobin concentrations during pregnancy; however, it is unclear whether those relations are attributable to conditions of low and high iron status or to other mechanisms. We summarized current evidence from human studies regarding the association between birth outcomes and maternal hemoglobin concentrations or iron status. We also reviewed effects of iron supplementation on birth outcomes among women at low risk of ID and the potential mechanisms for adverse effects of high iron status during pregnancy. Overall, we confirmed a U-shaped curve for the risk of adverse birth outcomes with maternal hemoglobin concentrations, but the relations differ by trimester. For low hemoglobin concentrations, the link with adverse outcomes is more evident when hemoglobin concentrations are measured in early pregnancy. These relations generally became weaker or nonexistent when hemoglobin concentrations are measured in the second or third trimesters. Associations between high hemoglobin concentration and adverse birth outcomes are evident in all 3 trimesters but evidence is mixed. There is less evidence for the associations between maternal iron status and adverse birth outcomes. Most studies used serum ferritin (SF) concentrations as the indicator of iron status, which makes the interpretation of results challenging because SF concentrations increase in response to inflammation or infection. The effect of iron supplementation during pregnancy may depend on initial iron status. There are several mechanisms through which high iron status during pregnancy may have adverse effects on birth outcomes, including oxidative stress, increased blood viscosity, and impaired systemic response to inflammation and infection. Research is needed to understand the biological processes that underlie the U-shaped curves

  12. Relationship between Sucralose Consumption and Serum Concentration of Glycosylated Hemoglobin in People with Type 2 Diabetes Mellitus without Complications

    Directory of Open Access Journals (Sweden)

    María del Carmen Cortés-López

    2017-11-01

    Full Text Available People who live with diabetes consume sucralose to control their blood glucose, but there is a controversy about this topic. To evaluate the relationship between sucralose consumption and serum concentration of glycosylated hemoglobin in people with Type 2 Diabetes Mellitus without complications. Cross-sectional study. Universe of 27 214 people with Type 2 Diabetes Mellitus without complications, users of a primary care unit from the Instituto Mexicano del Seguro Social in the state of Jalisco, Mexico. Simple probabilistic sample, n = 194 (p = 0,05. Propositive sampling. Selection criteria: adults of any gender and education level who agreed to participate. Variables: sociodemographic, anthropometric, clinical and dietary. Data collection instruments: Sociodemographic questionnaire, Tanita Fitscan© 585 scale, Tanita Fitscan© HR-200 stadiometer, Body Flex© tape-measure, Slim Guide© plicometer, Afinion© AS100 analyzer, and Frequency of Food Consumption Questionnaire. Information sources: clinical files and Mexican System of Equivalent Foods. Analysis: descriptive and inferential statistics (p ≤ 0,05. 194 people. Mean age 60,23 ± 11,16, interval 28-93 years. 56,2% females and 43,8% males. Difference between glycosilated hemoglobin means: sucralose consumers 7,5% ± 1,7%, no sucralose consumers 8,1% ± 2,1% (p < 0,01. Association force “sucralose consumption/high glycosilated hemoglobin concentration” OR = 1,42 (CI95% 0,63, 3,21. Lineal correlation “quarterly sucralose consumption/serum concentration of glycosylated hemoglobin” ρ = -0,754 (R2 = 0,0057, p = 0,333. This results were partially consistent to the pre-existing literature. Studies with representative stratified samples and control of dietary variables are required for better results.

  13. FORMATION OF HEMOGLOBIN AND ALBUMIN ADDUCTS OF BENZENE OXIDE IN MOUSE, RAT, AND HUMAN BLOOD

    Science.gov (United States)

    Little is known about the formation and disposition of benzene oxide (BO), the initial metabolite arising from oxidation of benzene by cytochrome P450. In this study, reactions of BO with hemoglobin (Hb) and albumin (Alb) were investigated in blood from B6C3F1 mice, F344 rats, ...

  14. Feasibility of direct oxygenation of primary-cultured rat hepatocytes using polyethylene glycol-decorated liposome-encapsulated hemoglobin (LEH).

    Science.gov (United States)

    Naruto, Hirosuke; Huang, Hongyun; Nishikawa, Masaki; Kojima, Nobuhiko; Mizuno, Atsushi; Ohta, Katsuji; Sakai, Yasuyuki

    2007-10-01

    We tested the short-term efficacy of liposome-encapsulated hemoglobin (LEH) in cultured rat hepatocytes. Supplementation with LEH (20% of the hemoglobin concentration of blood) did not lower albumin production in static culture, and completely reversed the cell death and deterioration in albumin production caused by an oxygen shortage in 2D flat-plate perfusion bioreactors.

  15. Tranexamic acid administration to older patients undergoing primary total hip arthroplasty conserves hemoglobin and reduces blood loss.

    Science.gov (United States)

    El Beheiry, Hossam; Lubberdink, Ashley; Clements, Nigel; Dihllon, Kiran; Sharma, Vicky

    2018-06-01

    Tranexamic acid effects in older people are difficult to predict. This study investigated the following research questions: 1) Is tranexamic acid effective in older patients undergoing primary total hip arthroplasty (THA)? and 2) Is there a difference in the effect of tranexamic acid between younger and older patients? This was a 2-phase retrospective matched-pair study of patients who underwent THA in 2007-2013. All procedures were performed by surgeons with at least 10 years' experience as senior consultant. In the first phase, 58 patients aged 65 years or more who received tranexamic acid were matched 1:1 with patients who did not receive tranexamic acid for age, sex, American Society of Anesthesiologists (ASA) classification and body mass index. In the second phase, 58 patients aged 65 years or more who received tranexamic acid were matched 1:1 with patients less than 65 years of age who received tranexamic acid for sex, ASA classification and body mass index. The primary outcome measures were percent maximum decrease in hemoglobin level and estimated blood loss after surgery. In the first phase, patients who received tranexamic acid conserved postoperative hemoglobin by a mean of 10.26 g/L (standard deviation [SD] 9.89 g/L) compared to the control group ( p Tranexamic acid reduced the postoperative decrease in hemoglobin level and blood loss in older patients. Moreover, the significant hemoglobin-sparing effect of tranexamic acid in older patients was similar to that observed in younger patients.

  16. In vivo integrated photoacoustic and confocal microscopy of hemoglobin oxygen saturation and oxygen partial pressure.

    Science.gov (United States)

    Wang, Yu; Hu, Song; Maslov, Konstantin; Zhang, Yu; Xia, Younan; Wang, Lihong V

    2011-04-01

    We developed dual-modality microscope integrating photoacoustic microscopy (PAM) and fluorescence confocal microscopy (FCM) to noninvasively image hemoglobin oxygen saturation (sO₂) and oxygen partial pressure (pO₂) in vivo in single blood vessels with high spatial resolution. While PAM measures sO₂ by imaging hemoglobin optical absorption at two wavelengths, FCM quantifies pO₂ using phosphorescence quenching. The variations of sO₂ and pO₂ values in multiple orders of vessel branches under hyperoxic (100% oxygen) and normoxic (21% oxygen) conditions correlate well with the oxygen-hemoglobin dissociation curve. In addition, the total concentration of hemoglobin is imaged by PAM at an isosbestic wavelength.

  17. Nonlinear photoacoustic spectroscopy of hemoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P.; Xia, Jun; Wang, Lihong V., E-mail: LHWANG@WUSTL.EDU [Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, St. Louis, Missouri 63130 (United States)

    2015-05-18

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

  18. Nonlinear photoacoustic spectroscopy of hemoglobin.

    Science.gov (United States)

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P; Xia, Jun; Wang, Lihong V

    2015-05-18

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

  19. Nonlinear photoacoustic spectroscopy of hemoglobin

    International Nuclear Information System (INIS)

    Danielli, Amos; Maslov, Konstantin; Favazza, Christopher P.; Xia, Jun; Wang, Lihong V.

    2015-01-01

    As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography

  20. Evaluation on the detection limit of blood hemoglobin using photolepthysmography based on path-length optimization

    Science.gov (United States)

    Sun, Di; Guo, Chao; Zhang, Ziyang; Han, Tongshuai; Liu, Jin

    2016-10-01

    The blood hemoglobin concentration's (BHC) measurement using Photoplethysmography (PPG), which gets blood absorption to near infrared light from the instantaneous pulse of transmitted light intensity, has not been applied to the clinical use due to the non-enough precision. The main challenge might be caused of the non-enough stable pulse signal when it's very weak and it often varies in different human bodies or in the same body with different physiological states. We evaluated the detection limit of BHC using PPG as the measurement precision level, which can be considered as a best precision result because we got the relative stable subject's pulse signals recorded by using a spectrometer with high signal-to-noise ratio (SNR) level, which is about 30000:1 in short term. Moreover, we optimized the used pathlength using the theory based on optimum pathlength to get a better sensitivity to the absorption variation in blood. The best detection limit was evaluated as about 1 g/L for BHC, and the best SNR of pulse for in vivo measurement was about 2000:1 at 1130 and 1250 nm. Meanwhile, we conclude that the SNR of pulse signal should be better than 400:1 when the required detection limit is set to 5 g/L. Our result would be a good reference to the BHC measurement to get a desired BHC measurement precision of real application.

  1. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Ghali, M.; Mortada, S.

    2006-01-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  2. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Galee, M.; Mortada, S.

    2005-05-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  3. Fish hemoglobins

    Directory of Open Access Journals (Sweden)

    P.C. de Souza

    2007-06-01

    Full Text Available Vertebrate hemoglobin, contained in erythrocytes, is a globular protein with a quaternary structure composed of 4 globin chains (2 alpha and 2 beta and a prosthetic group named heme bound to each one. Having myoglobin as an ancestor, hemoglobin acquired the capacity to respond to chemical stimuli that modulate its function according to tissue requirements for oxygen. Fish are generally submitted to spatial and temporal O2 variations and have developed anatomical, physiological and biochemical strategies to adapt to the changing environmental gas availability. Structurally, most fish hemoglobins are tetrameric; however, those from some species such as lamprey and hagfish dissociate, being monomeric when oxygenated and oligomeric when deoxygenated. Fish blood frequently possesses several hemoglobins; the primary origin of this finding lies in the polymorphism that occurs in the globin loci, an aspect that may occasionally confer advantages to its carriers or even be a harmless evolutionary remnant. On the other hand, the functional properties exhibit different behaviors, ranging from a total absence of responses to allosteric regulation to drastic ones, such as the Root effect.

  4. Effect of neonatal hemoglobin concentration on long-term outcome of infants affected by fetomaternal hemorrhage.

    Science.gov (United States)

    Kadooka, Mizuho; Kato, Hiromi; Kato, Akihiko; Ibara, Satoshi; Minakami, Hisanori; Maruyama, Yuko

    2014-09-01

    Fetomaternal hemorrhage (FMH) can cause severe morbidity. However, perinatal risk factors for long-term poor outcome due to FMH have not been extensively studied. To determine which FMH infants are likely to have neurological sequelae. A single-center retrospective observational study. Perinatal factors, including demographic characteristics, Kleihauer-Betke test, blood gas analysis, and neonatal blood hemoglobin concentration ([Hb]), were analyzed in association with long-term outcomes. All 18 neonates referred to a Neonatal Intensive Care Unit of Kagoshima City Hospital and diagnosed with FMH during a 15-year study period. All had a neonatal [Hb] neonates tested had Kleihauer-Betke test result >4.0%. Poor long-term outcome was defined as any of the following determined at 12 month old or more: cerebral palsy, mental retardation, attention deficit/hyperactivity disorder, and epilepsy. Nine of the 18 neonates exhibited poor outcomes. Among demographic characteristics and blood variables compared between two groups with poor and favorable outcomes, significant differences were observed in [Hb] (3.6±1.4 vs. 5.4±1.1g/dL, P=0.01), pH (7.09±0.11 vs. 7.25±0.13, P=0.02) and base deficits (17.5±5.4 vs. 10.4±6.0mmol/L, P=0.02) in neonatal blood, and a number of infants with [Hb]≤4.5g/dL (78%[7/9] vs. 22%[2/9], P=0.03), respectively. The base deficit in neonatal arterial blood increased significantly with decreasing neonatal [Hb]. Severe anemia causing severe base deficit is associated with neurological sequelae in FMH infants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Effect of Graded Levels of Soybean Hull on Blood, Carcass and ...

    African Journals Online (AJOL)

    Each treatment was replicated 3 times with 2 pigs per replicate placed on concrete-floored pens. ... Results showed that pigs fed the control diets had comparable (p>0.05) packed cell volume (PCV), hemoglobin concentration (Hb), red blood cell counts (RBC), white blood cell counts (WBC), mean corpuscular hemoglobin ...

  6. Diffuse and localized reflectance measurements of hemoglobin and hematocrit in human skin

    Science.gov (United States)

    Khalil, Omar S.; Wu, Xiaomao; Yeh, Shu-Jen; Jeng, Tzyy-Wen

    2001-05-01

    We conducted visible/near infrared optical measurements on the forearm of human subjects using a commercial diffuse reflectance spectrophotometer, and a breadboard temperature- controlled localized reflectance tissue photometer. Calibration relationships were established between skin reflectance signal and reference blood hemoglobin (Hb) concentration, or hematocrit values (Hct). These were then used to predict Hb and Hct values from optical measurement in a cross validation analysis. Different linear least- squares models for the prediction of Hb and Hct are presented and shows the ability to predict both. It was possible to screen prospective blood donors with low Hb concentration. It was possible to predict anemic subjects in the limited prospective blood donor population.

  7. The Reaction of Oxy Hemoglobin with Nitrite

    DEFF Research Database (Denmark)

    Hathazi, Denisa; Scurtu, Florina; Bischin, Cristina

    2018-01-01

    The autocatalytic reaction between nitrite and the oxy form of globins involves free radicals. For myoglobin (Mb), an initial binding of nitrite to the iron-coordinated oxygen molecule was proposed; the resulting ferrous-peroxynitrate species was not detected, but its decay product, the high...... to a simple kinetic model involving a transient met-aqua form, in contrast to the ferryl detected in the case of Mb in a similar reaction sequence. These data are in line with a previous observation of a transient accumulation of ferryl Hb under auto-catalytic conditions at much lower concentrations......-peroxynitrate. Density functional theory (DFT) calculations support this latter assignment. The reaction allows for differentiating between the reactivities of various chemically modified hemoglobins, including candidates for blood substitutes. Polymerization of hemoglobin slows the nitrite-induced oxidation, in sharp...

  8. Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants

    Science.gov (United States)

    Edwards, Rebecca L.; Griffiths, Paul; Bunch, Josephine; Cooper, Helen J.

    2012-11-01

    We have previously shown that liquid microjunction surface sampling of dried blood spots coupled with high resolution top-down mass spectrometry may be used for screening of common hemoglobin variants HbS, HbC, and HbD. In order to test the robustness of the approach, we have applied the approach to unknown hemoglobin variants. Six neonatal dried blood spot samples that had been identified as variants, but which could not be diagnosed by current screening methods, were analyzed by direct surface sampling top-down mass spectrometry. Both collision-induced dissociation and electron transfer dissociation mass spectrometry were employed. Four of the samples were identified as β-chain variants: two were heterozygous Hb D-Iran, one was heterozygous Hb Headington, and one was heterozygous Hb J-Baltimore. The fifth sample was identified as the α-chain variant heterozygous Hb Phnom Penh. Analysis of the sixth sample suggested that it did not in fact contain a variant. Adoption of the approach in the clinic would require speed in both data collection and interpretation. To address that issue, we have compared manual data analysis with freely available data analysis software (ProsightPTM). The results demonstrate the power of top-down proteomics for hemoglobin variant analysis in newborn samples.

  9. Decreasing the critical value of hemoglobin required for physician notification reduces the rate of blood transfusions

    Directory of Open Access Journals (Sweden)

    Larson EA

    2016-06-01

    Full Text Available Eric A Larson,1 Paul A Thompson,1,2 Zachary K Anderson,3 Keith A Anderson,4 Roxana A Lupu,1 Vicki Tigner,5 Wendell W Hoffman6,7 1Department of Internal Medicine, 2Department of Pediatrics, Sanford School of Medicine, University of South Dakota, Sioux Falls, SD, 3Department of Internal Medicine, Fairview Health Services, Edina, MN, 4Department of Laboratory Medicine, Sanford School of Medicine, University of South Dakota, 5Medical Staff Services, 6Department of Infectious Disease, Sanford Health, Sanford USD Medical Center, 7Department of Infectious Disease, Sanford School of Medicine, University of South Dakota, Sioux Falls, SD, USAAbstract: Red blood cell transfusions have been cited as one of the most overused therapeutic interventions in the USA. Excessively aggressive transfusion practices may be driven by mandatory physician notification of critical hemoglobin values that do not generally require transfusion. We examined the effect of decreasing the critical value of hemoglobin from 8 to 7 g/dL at our institution. Along with this change, mandatory provider notification for readings between 7 and 8 g/dL was rescinded. Transfusion rates were compared retrospectively during paired 5-month periods for patients presenting in three key hemoglobin ranges (6.00–6.99, 7.00–7.99, and 8.00–8.99 g/dL. A change in transfusion practices was hypothesized in the 7–8 g/dL range, which was no longer labeled critical and for which mandated physician calls were rescinded. Transfusion rates showed a statistically significant 8% decrease (P≤0.0001 during the 5-month period post change in our transfusion practices. This decrease in the 7.00–7.99 g/dL range was significantly greater than the 2% decrease observed in either the 6–6.99 g/dL (P=0.0017 or 8–8.99 g/dL (P≤0.0001 range. Cost savings of up to $700,000/year were extrapolated from our results showing 491 fewer units of red blood cells transfused during the 5-month post change. These cost

  10. Point-of-care blood gases, electrolytes, chemistries, hemoglobin, and hematocrit measurement in venous samples from pet rabbits.

    Science.gov (United States)

    Selleri, Paolo; Di Girolamo, Nicola

    2014-01-01

    Point-of-care testing is an attractive option in rabbit medicine, because it permits rapid analysis of a panel of electrolytes, chemistries, blood gases, hemoglobin, and hematocrit, requiring only 65 μL of blood. The purpose of this study was to evaluate the performance of a portable clinical analyzer for measurement of pH, partial pressure of CO2, Na, chloride, potassium, blood urea nitrogen, glucose, hematocrit, and hemoglobin in healthy and diseased rabbits. Blood samples obtained from 30 pet rabbits were analyzed immediately after collection by the portable clinical analyzer (PCA) and immediately thereafter (time <20 sec) by a reference analyzer. Bland-Altman plots and Passing-Bablok regression analysis were used to compare the results. Limits of agreement were wide for all the variables studied, with the exception of pH. Most variables presented significant proportional and/or constant bias. The current study provides sufficient evidence that the PCA presents reliability for pH, although its low agreement with a reference analyzer for the other variables does not support their interchangeability. Limits of agreement provided for each variable allow researchers to evaluate if the PCA is reliable enough for their scope. To the authors' knowledge, the present is the first report evaluating a PCA in the rabbit.

  11. Red blood cell 2,3-diphosphoglycerate concentration and in vivo P50 during early critical illness.

    Science.gov (United States)

    Ibrahim, Ezz el din S; McLellan, Stuart A; Walsh, Timothy S

    2005-10-01

    To measure red blood cell 2,3-diphosphoglycerate (RBC 2,3-DPG) concentrations in early critical illness; to investigate factors associated with high or low RBC 2,3-DPG levels; to calculate in vivo P50 in patients with early critical illness; and to explore the relationship between RBC 2,3-DPG and intensive care mortality. Prospective cohort study. General medical-surgical intensive care unit (ICU) of a major Scottish teaching hospital. One-hundred eleven critically ill patients during the first 24 hrs in the ICU with no history of chronic hematologic disorders or RBC transfusion within 24 hrs and 34 age- and sex-matched healthy reference subjects. None. We measured RBC 2,3-DPG concentration, plasma biochemistry values, and arterial blood gas parameters. On average, RBC 2,3-DPG was lower among critically ill patients than controls (mean [sd], 14.1 [6.3] vs. 16.7 [3.7] mumol/g hemoglobin; p = .004) and had a wider range of values (patients, 3.2-32.5 mumol/g hemoglobin; reference group, 9.1-24.3). Regression analysis indicated a strong independent association between plasma pH and RBC 2,3-DPG (B, 32.15 [95% confidence interval, 19.07-46.22], p level was normal (3.8 kPa) but varied widely among patients (range, 2.0-5.5 kPa). RBC 2,3-DPG concentration was similar for ICU survivors and nonsurvivors. RBC 2,3-DPG concentrations vary widely among critically ill patients. Acidosis is associated with lower RBC 2,3-DPG concentrations, but anemia is not associated with a compensatory increase in RBC 2,3-DPG early in critical illness. Lower RBC 2,3-DPG concentrations during the first 24 hrs of intensive care are not associated with higher ICU mortality.

  12. Respiratory adaptations in carp blood. Influences of hypoxia, red cell organic phosphates, divalent cations and CO2 on hemoglobin-oxygen affinity

    DEFF Research Database (Denmark)

    Weber, Roy E.; Lykkeboe, G.

    1978-01-01

    This study concerns the adaptation of oxygen transporting function of carp blood to environment hypoxia, tracing the roles played by erythrocytic cofactors, inorganic cations, carbon dioxide and hemoglobin multiplicity. Carp acclimated to hypoxia ( 30 mmHg) display striking increases in blood oxy...

  13. High-affinity hemoglobin and blood oxygen saturation in diving emperor penguins.

    Science.gov (United States)

    Meir, Jessica U; Ponganis, Paul J

    2009-10-01

    The emperor penguin (Aptenodytes forsteri) thrives in the Antarctic underwater environment, diving to depths greater than 500 m and for durations longer than 23 min. To examine mechanisms underlying the exceptional diving ability of this species and further describe blood oxygen (O2) transport and depletion while diving, we characterized the O2-hemoglobin (Hb) dissociation curve of the emperor penguin in whole blood. This allowed us to (1) investigate the biochemical adaptation of Hb in this species, and (2) address blood O2 depletion during diving, by applying the dissociation curve to previously collected partial pressure of O2 (PO2) profiles to estimate in vivo Hb saturation (SO2) changes during dives. This investigation revealed enhanced Hb-O2 affinity (P50=28 mmHg, pH 7.5) in the emperor penguin, similar to high-altitude birds and other penguin species. This allows for increased O2 at low blood PO2 levels during diving and more complete depletion of the respiratory O2 store. SO2 profiles during diving demonstrated that arterial SO2 levels are maintained near 100% throughout much of the dive, not decreasing significantly until the final ascent phase. End-of-dive venous SO2 values were widely distributed and optimization of the venous blood O2 store resulted from arterialization and near complete depletion of venous blood O2 during longer dives. The estimated contribution of the blood O2 store to diving metabolic rate was low and highly variable. This pattern is due, in part, to the influx of O2 from the lungs into the blood during diving, and variable rates of tissue O2 uptake.

  14. Single-cell measurement of red blood cell oxygen affinity

    OpenAIRE

    Caprio, Di; Stokes, Chris; Higgins, John M.; Schonbrun, Ethan

    2015-01-01

    Oxygen is transported throughout the body by hemoglobin in red blood cells. While the oxygen affinity of blood is well understood and is routinely assessed in patients by pulse oximetry, variability at the single-cell level has not been previously measured. In contrast, single-cell measurements of red blood cell volume and hemoglobin concentration are taken millions of times per day by clinical hematology analyzers and are important factors in determining the health of the hematologic system....

  15. Positive Association of Vitamin E Supplementation with Hemoglobin Levels in Mildly Anemic Healthy Pakistani Adults.

    Science.gov (United States)

    Jilani, Tanveer; Azam, Iqbal; Moiz, Bushra; Mehboobali, Naseema; Perwaiz Iqbal, Mohammad

    2015-01-01

    Hemoglobin levels slightly below the lower limit of normal are common in adults in the general population in developing countries. A few human studies have suggested the use of antioxidant vitamins in the correction of mild anemia. The objective of the present study was to investigate the association of vitamin E supplementation in mildly anemic healthy adults with post-supplemental blood hemoglobin levels in the general population of Karachi, Pakistan. In a single-blinded and placebo-controlled randomized trial, 124 mildly anemic subjects from the General Practitioners' Clinics and personnel of the Aga Khan University were randomized into intervention (n = 82) and control (n = 42) group. In the intervention group, each subject was given vitamin E (400 mg) everyday for a period of three months, while control group subjects received a placebo. Eighty six subjects completed the trial. Fasting venous blood was collected at baseline and after three months of supplementation. Hemoglobin levels and serum/plasma concentrations of vitamin E, vitamin B12, folate, ferritin, serum transferrin receptor (sTfR), glucose, total cholesterol, triglycerides, LDL-cholesterol, HDL-cholesterol, creatinine, total-antioxidant-status and erythropoietin were measured and analyzed using repeated measures ANOVA and multiple linear regression. The adjusted regression coefficients (β) and standard error [SE(β)] of the significant predictors of post-supplemental hemoglobin levels were serum concentration of vitamin E (0.983[0.095]), gender (- 0.656[0.244]), sTfR (- 0.06[0.02]) and baseline hemoglobin levels (0.768[0.077]). The study showed a positive association between vitamin E supplementation and enhanced hemoglobin levels in mildly anemic adults.

  16. Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood

    NARCIS (Netherlands)

    Maas, BHA; Buursma, A; Ernst, RAJ; Maas, AHJ; Zijlstra, WG

    We investigated the suitability of a lyophilized bovine hemoglobin (LBH) preparation containing various fractions of oxyhemoglobin (O(2)Hb), carboxyhemoglobin (COHb), and methemoglobin (MetHb) for quality assessment in multicomponent analysis (MCA) of hemoglobin derivatives. It was demonstrated that

  17. Lyophilized bovine hemoglobin as a possible reference material for the determination of hemoglobin derivatives in human blood

    NARCIS (Netherlands)

    Maas, BHA; Buursma, A; Ernst, RAJ; Maas, AHJ; Zijlstra, WG

    1998-01-01

    We investigated the suitability of a lyophilized bovine hemoglobin (LBH) preparation containing various fractions of oxyhemoglobin (O(2)Hb), carboxyhemoglobin (COHb), and methemoglobin (MetHb) for quality assessment in multicomponent analysis (MCA) of hemoglobin derivatives. It was demonstrated that

  18. Radioprotective properties of some heterocyclic nitrogenous compounds against changes in hemoglobin concentration and hematocrit value in x-irradiated mice

    International Nuclear Information System (INIS)

    Rousdhy, H.; Pierotti, T.; Polverelli, M.

    1969-01-01

    Radioprotective properties of imidazole and benzimidazole have been proved in previous works. In this study, authors try to demonstrate radioprotective action of these compounds in comparison with cysteamine upon the hematopoietic system after lethal X-irradiation. Results show: no drastic variations of hematologic constants (hemoglobin concentration and hematocrit value) after intraperitoneal injection of radioprotective compounds apart certain apparent reactions with the heterocyclic compounds; the better radioprotective action of benzimidazole. Twenty five days after irradiation, hemoglobin concentration and hematocrit of radio protected mice return to normal values. (author) [fr

  19. Antimicrobial activity and safety evaluation of peptides isolated from the hemoglobin of chickens.

    Science.gov (United States)

    Hu, Fengjiao; Wu, Qiaoxing; Song, Shuang; She, Ruiping; Zhao, Yue; Yang, Yifei; Zhang, Meikun; Du, Fang; Soomro, Majid Hussain; Shi, Ruihan

    2016-12-05

    Hemoglobin is a rich source of biological peptides. As a byproduct and even wastewater of poultry-slaughtering facilities, chicken blood is one of the most abundant source of hemoglobin. In this study, the chicken hemoglobin antimicrobial peptides (CHAP) were isolated and the antimicrobial and bactericidal activities were tested by the agarose diffusion assay, minimum inhibitory concentration (MIC) analysis, minimal bactericidal concentration (MBC) analysis, and time-dependent inhibitory and bactericidal assays. The results demonstrated that CHAP had potent and rapid antimicrobial activity against 19 bacterial strains, including 9 multidrug-resistant bacterial strains. Bacterial biofilm and NaCl permeability assays, transmission electron microscopy (TEM) and scanning electron microscopy (SEM) were further performed to detect the mechanism of its antimicrobial effect. Additionally, CHAP showed low hemolytic activity, embryo toxicity, and high stability in different temperatures and animal plasma. CHAP may have great potential for expanding production and development value in animal medication, the breeding industry and environment protection.

  20. Short report: evaluation of a simple and inexpensive photometric device for the measurement of hemoglobin

    NARCIS (Netherlands)

    Borrmann, Steffen; Oyakhirome, Sunny; Esser, Gilbert; Trinkle, Cordula; Issifou, Saadou; Grobusch, Martin P.; Krishna, Sanjeev; Kremsner, Peter G.

    2004-01-01

    We have evaluated the accuracy of a simple and inexpensive photometric device (DHT) for the estimation of the blood concentration of hemoglobin by comparison with an automated, high-resolution, flow cytometry-based hematology analyzer (CellDyn 3000) and a centrifugal quantitative buffy coat

  1. The variation profile of blood components indicates the degree of severity in psoriasis as inflammatory disease

    International Nuclear Information System (INIS)

    Mahesar, S.M.; Dahot, M.U.

    2010-01-01

    To evaluate the changes occurring in blood cells and hemoglobin concentration in 158 subjects recruited. For the study comprised (44) psoriatic males and (35) psoriatic females. The blood sample analyses, microscopically. White blood cells shows higher count while neutrophils and lymphocytes showed a marked enhancement in psoriatic samples. Erythrocyte sedimentation rate was measured by Western Green method. ESR in psoriatic male patients mean 31+-10 hgmm/hr opposed to 9.5+-4.1 hgmm/hr in healthy males and in female psoriatic patients mean 34+-12 hgmm/hr against 15+-3 hgmm/hr healthy females was noted. Elevation of erythrocyte sedimentation rate was observed in psoriatic patients. The mean hemoglobin level (cyanide method) in psoriatic male was 12+-1.2 g/dl opposed to 15.2+-1.3 g/dl in healthy males while in psoriatic females it was 11.1+-1.4 g/dl as opposed to 14+-1.6 g/dl in healthy females. Hemoglobin shows reduced concentration in psoriatic patients. The marked changes in white blood sells, Erythrocyte sedimentation rate and hemoglobin concentration indicates psoriasis as inflammatory disease. (author)

  2. Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions

    Directory of Open Access Journals (Sweden)

    Chaudhary R

    2017-07-01

    Full Text Available Rajendra Chaudhary,1 Anju Dubey,2 Atul Sonker3 1Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, 2Department of Transfusion Medicine, T.S. Misra Medical College and Hospital, 3Department of Transfusion Medicine, Sanjay Gandhi Postgraduate Institute of Medical Sciences, Lucknow, India Abstract: Blood donor hemoglobin (Hb estimation is an important donation test that is performed prior to blood donation. It serves the dual purpose of protecting the donors’ health against anemia and ensuring good quality of blood components, which has an implication on recipients’ health. Diverse cutoff criteria have been defined world over depending on population characteristics; however, no testing methodology and sample requirement have been specified for Hb screening. Besides the technique, there are several physiological and methodological factors that affect accuracy and reliability of Hb estimation. These include the anatomical source of blood sample, posture of the donor, timing of sample and several other biological factors. Qualitative copper sulfate gravimetric method has been the archaic time-tested method that is still used in resource-constrained settings. Portable hemoglobinometers are modern quantitative devices that have been further modified to reagent-free cuvettes. Furthermore, noninvasive spectrophotometry was introduced, mitigating pain to blood donor and eliminating risk of infection. Notwithstanding a tremendous evolution in terms of ease of operation, accuracy, mobility, rapidity and cost, a component of inherent variability persists, which may partly be attributed to pre-analytical variables. Hence, blood centers should pay due attention to validation of test methodology, competency of operating staff and regular proficiency testing of the outputs. In this article, we have reviewed various regulatory guidelines, described the variables that affect the measurements and compared the validated

  3. Modification of hemoglobin level and hematocrit value in the peripheral blood of mice after 45Ca internal irradiation by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Bhagat, R.M.; Kumar, A.

    1986-01-01

    Radioprotective effect of MPG has been studied on the hemoglobin level and hematocrit value of peripheral blood of Swiss albino mice against radiation-induced changes after injecting radiocalcium ( 45 Ca) at the dose level of 37 kBq/g body weight. MPG was injected 15-30 minutes before 45 Ca injection at dose of 20 mg/kg body weight intraperitoneally and also MPG was injected at various repeated doses. It has been observed that MPG in repeated doses is effective in reducing the radiation-induced changes in the hemoglobin and hematocrit value of peripheral blood of Swiss albino mice following 45 Ca internal irradiation. (author)

  4. [Noninvasive detection of hematocrit and the mean corpuscular hemoglobin concentration levels by Vis-NIR spectroscopy].

    Science.gov (United States)

    Zhao, Jing; Lin, Ling; Lu, Xiao-Zuo; Li, Gang

    2014-03-01

    Hematocrit (HCT) and mean hemoglobin concentration(MCHC) play a very important role in preventing cardiovascular disease and anemia. A method was developed on the basis of spectroscopy to detect HCT and MCHC non-invasively and accurately. The anatomical study showed that the blood rheology abnormalities and blood viscosity's changes can cause the changes of tongue, so there is a certain correlation between tongue and blood components. Reflectance spectrums from the tongue tips of 240 volunteers were collected, then the tongue pictures were captured and the biochemical analysis results were recorded at the same time. The 240 samples were separated into two parts: calibration sample and test sample. Spectra were then subjected to a partial least squares regression (PLSR) analysis to develop mathematics models for predicting HCT levels. The correlation between the data and prediction of HCT and MCHC yielded calibration samples value of 0.998 and 0.938. HCT and MCHC levels of test samples predicted by this model from Visible-Near infrared spectra provided a coefficient of determination in prediction of 0.979 and 0.883 with an average relative error of prediction of 1.65% and 1.88%, a root mean square error of prediction of 4.066 and 4.139. From the experiment results we can see that the model which was built before can better predict the HCT and MCHC, and the results also showed that spectrometry method may provide a promising approach to the noninvasive measurement of human HCT and MCHC with a combination of PLSR analysis.

  5. NMR water-proton spin-lattice relaxation time of human red blood cells and red blood cell suspensions

    International Nuclear Information System (INIS)

    Sullivan, S.G.; Rosenthal, J.S.; Winston, A.; Stern, A.

    1988-01-01

    NMR water-proton spin-lattice relaxation times were studied as probes of water structure in human red blood cells and red blood cell suspensions. Normal saline had a relaxation time of about 3000 ms while packed red blood cells had a relaxation time of about 500 ms. The relaxation time of a red blood cell suspension at 50% hematocrit was about 750 ms showing that surface charges and polar groups of the red cell membrane effectively structure extracellular water. Incubation of red cells in hypotonic saline increases relaxation time whereas hypertonic saline decreases relaxation time. Relaxation times varied independently of mean corpuscular volume and mean corpuscular hemoglobin concentration in a sample population. Studies with lysates and resealed membrane ghosts show that hemoglobin is very effective in lowering water-proton relaxation time whereas resealed membrane ghosts in the absence of hemoglobin are less effective than intact red cells. 9 refs.; 3 figs.; 1 table

  6. Relationship between laparoscopic cholecystectomy operative time and carbonyl hemoglobin content

    Directory of Open Access Journals (Sweden)

    ZHANG Qi

    2013-06-01

    Full Text Available ObjectiveTo investigate whether operative time of laparoscopic cholecystectomy impacts the carbonyl hemoglobin (COHb concentration in peripheral blood. MethodsForty patients with gallstones and indications for laparoscopic cholecystectomy were enrolled in the study. Peripheral venous blood samples were collected at the beginning and end of the operative procedure. COHb concentration was measured by UV spectroscopy. The significance of changes in COHb concentration in relation to time of the operative procedure (rounded to the nearest minute was assessed by statistical correlation coefficient test. ResultsThe laparoscopic procedure was completed in 38 cases, and two patients required conversion to laparotomy. The content of COHb in peripheral venous blood had significantly increased during the laparoscopic operation (operation beginning: 11.07%±1.18% vs. operation end: 1.44%±0.26%, P<0.05. The change was positively correlated with operation time (r=0.85. ConclusionCarbon monoxide produced during the laparoscopic cholecystectomy procedure can lead to an increase in peripheral venous blood COHb. The longer the operation lasts, the greater the increase in COHb.

  7. Lower Hemoglobin Concentration Is Associated with Retinal Ischemia and the Severity of Diabetic Retinopathy in Type 2 Diabetes.

    Science.gov (United States)

    Traveset, Alicia; Rubinat, Esther; Ortega, Emilio; Alcubierre, Nuria; Vazquez, Beatriz; Hernández, Marta; Jurjo, Carmen; Espinet, Ramon; Ezpeleta, Juan Antonio; Mauricio, Didac

    2016-01-01

    Aims. To assess the association of blood oxygen-transport capacity variables with the prevalence of diabetic retinopathy (DR), retinal ischemia, and macular oedema in patients with type 2 diabetes mellitus (T2DM). Methods. Cross-sectional, case-control study (N = 312) with T2DM: 153 individuals with DR and 159 individuals with no DR. Participants were classified according to the severity of DR and the presence of retinal ischemia or macular oedema. Hematological variables were collected by standardized methods. Three logistic models were adjusted to ascertain the association between hematologic variables with the severity of DR and the presence of retinal ischemia or macular oedema. Results. Individuals with severe DR showed significantly lower hemoglobin, hematocrit, and erythrocyte levels compared with those with mild disease and in individuals with retinal ischemia and macular oedema compared with those without these disorders. Hemoglobin was the only factor that showed a significant inverse association with the severity of DR [beta-coefficient = -0.52, P value = 0.003] and retinal ischemia [beta-coefficient = -0.49, P value = 0.001]. Lower erythrocyte level showed a marginally significant association with macular oedema [beta-coefficient = -0.86, P value = 0.055]. Conclusions. In patients with DR, low blood oxygen-transport capacity was associated with more severe DR and the presence of retinal ischemia. Low hemoglobin levels may have a key role in the development and progression of DR.

  8. The Greenland shark Somniosus microcephalus-Hemoglobins and ligand-binding properties.

    Directory of Open Access Journals (Sweden)

    Roberta Russo

    Full Text Available A large amount of data is currently available on the adaptive mechanisms of polar bony fish hemoglobins, but structural information on those of cartilaginous species is scarce. This study presents the first characterisation of the hemoglobin system of one of the longest-living vertebrate species (392 ± 120 years, the Arctic shark Somniosus microcephalus. Three major hemoglobins are found in its red blood cells and are made of two copies of the same α globin combined with two copies of three very similar β subunits. The three hemoglobins show very similar oxygenation and carbonylation properties, which are unaffected by urea, a very important compound in marine elasmobranch physiology. They display identical electronic absorption and resonance Raman spectra, indicating that their heme-pocket structures are identical or highly similar. The quaternary transition equilibrium between the relaxed (R and the tense (T states is more dependent on physiological allosteric effectors than in human hemoglobin, as also demonstrated in polar teleost hemoglobins. Similar to other cartilaginous fishes, we found no evidence for functional differentiation among the three isoforms. The very similar ligand-binding properties suggest that regulatory control of O2 transport may be at the cellular level and that it may involve changes in the cellular concentrations of allosteric effectors and/or variations of other systemic factors. The hemoglobins of this polar shark have evolved adaptive decreases in O2 affinity in comparison to temperate sharks.

  9. Is a blood sample for hemoglobins in the transfusional range reliable?

    Science.gov (United States)

    López, A; Gómez, L; Petinal, G; Adán, N; Alvarado, S; Carballo, N

    2018-02-27

    To evaluate the correlation and agreement in our unit and population of hemoglobin in gasometry versus hematology analyzer, to evaluate errors in transfusion or lack thereof. strong association between Point-of-care (POC) and hematimetry, with P<.001, with a coefficient of determination r 2 of 0.56, an intraclass correlation coefficient of 0.63 and a Lin's concordance correlation coefficient of 0.65. For hemoglobins less than 7g/dL, a success rate of 29.41% was obtained. Low-moderate agreement of POC hemoglobin with standard haemothymetry. High probability of errors in the indication of transfusion based on gasometer hemoglobins, especially in low hemoglobins. Copyright © 2018 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. A study on the structures of hemoglobin of diabetic patients by EXAFS technique

    International Nuclear Information System (INIS)

    Wang Yinsong; Tan Mingguang; Zhang Guilin

    2001-01-01

    Hemoglobin was the carrier of oxygen in blood circulation. For the patients with diabetes mellitus the enhancement of glycidate hemoglobin in blood causes the decrease of oxygen transmission function. The local atomic structures of iron in hemoglobin were determined by EXAFS techniques. The relationship between diabetes mellitus and hemoglobin structures was observed. The blood samples were taken from normal people, slight and serious diabetic patients. The results show that the coordination number of iron atoms and Fe-O bond length were almost the same for the three samples. However, for the samples of serious diabetic patients the Fe-N bond length increases by about 0.002 nm, the possible reasons were the increase of deoxyhemoglobin contents in their blood

  11. Interaction of Jet Fuel Hydrocarbon Components with Red Blood Cells and Hemoglobin

    Science.gov (United States)

    2014-06-24

    Directorate (RHDJ), Wright-Patterson AFB, OH. The authors would like to thank Maj. Paul Eden, Nicole Schaeublin, Christin Grabinski, Dr. Jeff Gearhart...We would also like to thank LtCol. Norman Fox (Laboratory Flight Commander), Mrs. Nersa Loh (Supervisor, Transfusion Services), and Mr. Dan Fischer ...Approximately 7.8 mg of hemoglobin sample was concentrated into a total volume of 5 mL of Fischer PBS pH 7.5 buffer using an Amicon Centrifugal Filter Unit

  12. Lower versus higher hemoglobin threshold for transfusion in septic shock.

    Science.gov (United States)

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn; Wernerman, Jan; Guttormsen, Anne B; Karlsson, Sari; Johansson, Pär I; Aneman, Anders; Vang, Marianne L; Winding, Robert; Nebrich, Lars; Nibro, Helle L; Rasmussen, Bodil S; Lauridsen, Johnny R M; Nielsen, Jane S; Oldner, Anders; Pettilä, Ville; Cronhjort, Maria B; Andersen, Lasse H; Pedersen, Ulf G; Reiter, Nanna; Wiis, Jørgen; White, Jonathan O; Russell, Lene; Thornberg, Klaus J; Hjortrup, Peter B; Müller, Rasmus G; Møller, Morten H; Steensen, Morten; Tjäder, Inga; Kilsand, Kristina; Odeberg-Wernerman, Suzanne; Sjøbø, Brit; Bundgaard, Helle; Thyø, Maria A; Lodahl, David; Mærkedahl, Rikke; Albeck, Carsten; Illum, Dorte; Kruse, Mary; Winkel, Per; Perner, Anders

    2014-10-09

    Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay. The primary outcome measure was death by 90 days after randomization. We analyzed data from 998 of 1005 patients (99.3%) who underwent randomization. The two intervention groups had similar baseline characteristics. In the ICU, the lower-threshold group received a median of 1 unit of blood (interquartile range, 0 to 3) and the higher-threshold group received a median of 4 units (interquartile range, 2 to 7). At 90 days after randomization, 216 of 502 patients (43.0%) assigned to the lower-threshold group, as compared with 223 of 496 (45.0%) assigned to the higher-threshold group, had died (relative risk, 0.94; 95% confidence interval, 0.78 to 1.09; P=0.44). The results were similar in analyses adjusted for risk factors at baseline and in analyses of the per-protocol populations. The numbers of patients who had ischemic events, who had severe adverse reactions, and who required life support were similar in the two intervention groups. Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion at a lower threshold; the latter group received fewer transfusions. (Funded by the Danish Strategic Research Council and others; TRISS ClinicalTrials.gov number, NCT01485315.).

  13. Blood indicators of seasonal metabolic patterns in captive adult gray wolves

    Science.gov (United States)

    Seal, U.S.; Mech, L.D.

    1983-01-01

    Blood samples and physical data were collected weekly from a colony of gray wolves (Canis lupus) maintained under natural weather arid light conditions. Sampling over 33 continuous months indicated that hemoglobin, hematocrit, red blood cells, mean corpuscular hemoglobin concentration (MCHC), and thyroxine exhibited consistent circannual patterns of variation in both males and females. Hemoglobin levels peaked at 15-16 g/dl in January in females and at 16-17 g/dl in February in males, and were lowest in August at 10.5-11.5 g/dl (P patterns of hematocrit, red blood cells, and MCHC were similarly timed. Females also had a cyclic pattern of white blood cell counts and body weight; their weight peaked in early February and was lowest in August (P pattern.

  14. Drinking pattern and its relation to hemoglobin concentration in local brew consumers from the Kathmandu Region

    Institute of Scientific and Technical Information of China (English)

    Arun Kumar

    2009-01-01

    The study was conducted to determine the hemoglobin concentration in alcohol consumers (home made brew-Chang) and compare it with non- alcohohcs healthy subjects. Hemoglobin (Hb) concentration was determined in 2053 alcoholic consumers (males: 1056; females: 997) and was compared with 1 027 (males: 623; females: 404) healthy non-alcoholic con-trol subjects. The Hb concentration in alcoholic male and female were 13.42 ± 2.14 g/dL and 12.19 ± 1.55 g/dL compared with control showing 14.43 ± 1.07 g/dL and 12.73 ± 1.41 g/dL in males and females respectively. The differences in Hb concentration between alcoholic and non- alcoholic consumers were highly significant in both genders with a P value of 0. 000 674 in males and 0.004 732 in females. Alcohol Use Disorders Identification test (AUDIT) scores was advocated to alcoholic consum-ers to test the severity of drunkenness and disorders related to it. A total of 887 males and 663 females crossed the cut-off limits of ≥8 AUDIT scores showing the addiction towards drinking habits of local brew.

  15. Correlation between maternal and umbilical cord blood in pregnant women of Pokhara Valley: a cross sectional study.

    Science.gov (United States)

    Timilsina, Sameer; Karki, Sirisa; Gautam, Aajeevan; Bhusal, Pujan; Paudel, Gita; Sharma, Deepak

    2018-03-21

    Complete blood count is one of the routinely advised blood investigation during pregnancy. It is also utilized as a diagnostic tool for neonatal anemia, sepsis and determining hemostatic status of the newborn. The present study aims at estimating the complete blood count of maternal and umbilical cord blood at the time of delivery and to establish its correlation. This cross sectional study included 114 mothers and their healthy neonates born through normal vaginal delivery. Complete blood count of umbilical cord blood and maternal blood was estimated using automatic hematology analyzer. The mean maternal and neonatal hemoglobin concentration was 11.14 ± 1.39 g/dL and 16.34 ± 2.01 g/dL respectively. A significant positive correlation was found between maternal and fetal hemoglobin concentration (p correlation between maternal and fetal WBC, RBC and Platelet count was not statistically significant. A significant positive correlation was found between maternal and fetal MCV and MCH while PCV showed a non-significant positive correlation. There was moderately positive correlation between maternal and fetal hemoglobin, MCV and MCH. The cord blood hemoglobin was lower in babies born to anemic mothers. The decrease in hemoglobin followed the severity of anemia, however, the correlation did not exist in anemic mothers. It suggested that fetal hematological parameters are not reflective of maternal hemogram.

  16. A near infrared instrument to monitor relative hemoglobin concentrations of human bone tissue in vitro and in vivo

    Science.gov (United States)

    Aziz, Syed Mahfuzul; Khambatta, Faram; Vaithianathan, Tharshan; Thomas, John C.; Clark, Jillian M.; Marshall, Ruth

    2010-04-01

    A continuous wave near infrared instrument has been developed to monitor in vivo changes in the hemoglobin concentration of the trabecular compartment of human bone. The transmitter uses only two laser diodes of wavelengths 685 and 830 nm, and the receiver uses a single silicon photodiode operating in the photovoltaic mode. The functioning of the instrument and the depth of penetration of the near infrared signals was determined in vitro using tissue-equivalent phantoms. The instrument achieves a depth of penetration of approximately 2 cm for an optode separation of 4 cm and, therefore, has the capacity to interrogate the trabecular compartment of human bone. The functioning of the instrument was tested in vivo to evaluate the relative oxy-hemoglobin (HbO2) and deoxy-hemoglobin (Hb) concentrations of the proximal tibial bone of apparently healthy, normal weight, adult subjects in response to a 3 min on, 5 min off, vascular occlusion protocol. The traces of the relative Hb and HbO2 concentrations obtained were reproducible in controlled conditions. The instrument is relatively simple and flexible, and offers an inexpensive platform for further studies to obtain normative data for healthy cohorts, and to evaluate disease-specific performance characteristics for cohorts with vasculopathies of bone.

  17. Lower Hemoglobin Concentration Is Associated with Retinal Ischemia and the Severity of Diabetic Retinopathy in Type 2 Diabetes

    Science.gov (United States)

    Traveset, Alicia; Rubinat, Esther; Ortega, Emilio; Alcubierre, Nuria; Vazquez, Beatriz; Hernández, Marta; Jurjo, Carmen; Espinet, Ramon; Ezpeleta, Juan Antonio; Mauricio, Didac

    2016-01-01

    Aims. To assess the association of blood oxygen-transport capacity variables with the prevalence of diabetic retinopathy (DR), retinal ischemia, and macular oedema in patients with type 2 diabetes mellitus (T2DM). Methods. Cross-sectional, case-control study (N = 312) with T2DM: 153 individuals with DR and 159 individuals with no DR. Participants were classified according to the severity of DR and the presence of retinal ischemia or macular oedema. Hematological variables were collected by standardized methods. Three logistic models were adjusted to ascertain the association between hematologic variables with the severity of DR and the presence of retinal ischemia or macular oedema. Results. Individuals with severe DR showed significantly lower hemoglobin, hematocrit, and erythrocyte levels compared with those with mild disease and in individuals with retinal ischemia and macular oedema compared with those without these disorders. Hemoglobin was the only factor that showed a significant inverse association with the severity of DR [beta-coefficient = −0.52, P value = 0.003] and retinal ischemia [beta-coefficient = −0.49, P value = 0.001]. Lower erythrocyte level showed a marginally significant association with macular oedema [beta-coefficient = −0.86, P value = 0.055]. Conclusions. In patients with DR, low blood oxygen-transport capacity was associated with more severe DR and the presence of retinal ischemia. Low hemoglobin levels may have a key role in the development and progression of DR. PMID:27200379

  18. Changes in hemoglobin-oxygen affinity with shape variations of red blood cells

    Science.gov (United States)

    Chowdhury, Aniket; Dasgupta, Raktim; Majumder, Shovan K.

    2017-10-01

    Shape variations of red blood cells (RBCs) are known to occur upon exposure to various drugs or under diseased conditions. The commonly observed discocytic RBCs can be transformed to echinocytic or stomatocytic shape under such conditions. Raman spectra of the three major shape variations, namely discocyte, echinocyte, and stomatocyte, of RBCs were studied while subjecting the cells to oxygenated and deoxygenated conditions. Analysis of the recorded spectra suggests an increased level of hemoglobin (Hb)-oxygen affinity for the echinocytes. Also, some level of Hb degradation could be noticed for the deoxygenated echinocytes. The effects may arise from a reduced level of intracellular adenosine triphosphate in echinocytic cells and an increased fraction of submembrane Hb.

  19. Antithrombin activity, platelet count, hemoglobin concentration and hematocrit value determined immediately before vaginal delivery among healthy women.

    Science.gov (United States)

    Morikawa, Mamoru; Yamada, Takashi; Yamada, Takahiro; Koyama, Takahiro; Akaishi, Rina; Ishikawa, Satoshi; Takeda, Masamitsu; Nishida, Ryutaro; Araki, Naoto; Minakami, Hisanori

    2012-08-01

    To determine the normal reference values for antithrombin (AT) activity, platelet count (Plt), hemoglobin concentration (Hb), and hematocrit value (Ht) immediately before vaginal delivery among healthy pregnant women with singleton pregnancies and to determine association of these blood parameters with fetal growth. A complete blood count was performed and the AT activity was examined in 300 consecutive women admitted to hospital at > or = gestational week 36 for labor pains and/or the rupture of fetal membranes. All the women were normotensive and had singleton pregnancies, and none of the women had proteinuria, a weekly weight gain > or = 0.5 kg, or other specific complications upon admission. All the women attempted a vaginal delivery. The medians (5th-95th percentile) were 90% (71-110%) for AT activity, 234x10(9)/L (150-337x10(9)/L) for Plt, 11.0 g/dL (9.5-12.8 g/dL) for Hb, and 34.0% (30.4-38.6%) for Ht. Women with an Hb value of > or = the median (11.0 g/dL) gave birth to significantly smaller infants than their counterparts. A considerable number of healthy women exhibit a reduced AT activity and/or platelet count immediately before delivery. Hemoconcentration evidenced by a raised Hb value adversely effects on infant growth. Our data may be helpful when considering the normal ranges of these blood parameters for healthy parturient women.

  20. Optical sensor technology for a noninvasive medical blood diagnosis

    Science.gov (United States)

    Kraitl, Jens; Ewald, Hartmut; Gehring, Hartmut

    2007-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) and is used for a measurement of blood components. The fact that the absorption-coefficients μ a and scattering-coefficients μ s for blood differ at difference wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Deferrals between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous online monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods.

  1. Reference interval determination of hemoglobin fractions in umbilical cord and placental blood by capillary electrophoresis.

    Science.gov (United States)

    Bó, Suzane Dal; de Oliveira Lemos, Fabiane Kreutz; Pedrazzani, Fabiane Spagnol; Cagliari, Cláudia Rosa; Scotti, Luciana

    2016-04-01

    Umbilical cord and placental blood (UCPB) is a rich source of hematopoietic stem cells widely used to treat diseases that did not have effective treatments until recently. Umbilical cord and placental blood banks (UCPBBs) are needed to be created to store UCPB. UCPB is collected immediately after birth, processed, and frozen until infusion. Detection of abnormal hemoglobins is one of UCPB screening tests available. The objective of the present study was to determine the reference interval for HbA, HbF, and HbA2 in UCPB using capillary electrophoresis. Methods: Observational retrospective study of UCPB samples undergoing hemoglobin electrophoresis was performed between April 2012 and May 2013. We analyzed 273 UCPB samples. All cords met the criteria of BrasilCORD. We found 19.9% (10.5–36.7%) for HbA, 80.1% (62.7–89.4%) for HbF, and 0.1% (0.0–0.6%) for HbA2. Data were expressed as median (P2.5–P97.5). Establishing specific reference intervals is the best option for most tests because such ranges reflect the status of the population in which the tests will be applied. The use of appropriate reference intervals ensures that clinical labs provide reliable information, thus enabling clinicians to correctly interpret results and choose the best approach for the target population.

  2. Effect of chlorine toxicity on certain blood parameters of adult rainbow trout (Salmo gairdneri)

    Energy Technology Data Exchange (ETDEWEB)

    Zeitoun, I.H.

    1977-01-01

    In an effort to assess the mode of chlorine action on rainbow trout (Salmo gairdneri), hematocrit percentage, and hemoglobin, methemoglobin, reduced glutathione, plasma protein, and plasma hemoglobin concentrations were determined in four tests in which duplicate groups of approximately 15 fish each were exposed to 3.86, 2.47, 2.75, and 1.09 mq l/sup -1/ TRCl/sub 2/ for 8, 19, 20, and 29 minutes, respectively. Blood from fish exposed to chlorine was darker and thicker than that of the control. Chlorine seemed to diffuse readily through the gills, oxidizing the hemoglobin to methemoglobin and disrupting the erythrocyte membranes, resulting in hemolysis. Stress polycythemia was also due to the substantial increase of the hematocrit values and hemoglobin concentration. Hemoconcentration led to a significant rise in the reduced glutathione and plasma protein concentrations. The hemoconcentration seemed to interfere with the blood circulation and hinder the delivery of oxygen to tissues.

  3. Haptoglobin blood test

    Science.gov (United States)

    The haptoglobin blood test measures the level of haptoglobin in your blood. Haptoglobin is a protein produced by the liver. It attaches to a certain type of hemoglobin in the blood. Hemoglobin is a blood cell that carries oxygen.

  4. 70-year old female patient with mismatch between hematocrit and hemoglobin values: the effects of cold agglutinin on complete blood count.

    Science.gov (United States)

    Ercan, Serif; Calışkan, Mustafa; Koptur, Erhan

    2014-01-01

    There are a number of pre-analytical and analytical factors, which cause false results in the complete blood count. The present case identifies cold agglutinins as the cause for the mismatch between hematocrit and hemoglobin values. 70-year old female patient had a history of cerebrovascular diseases and rheumatoid arthritis. During routine laboratory examination, the patient had normal leukocyte and platelet counts; however, the hemoglobin (Hb: 105 g/L) and hematocrit (HCT: 0.214 L/L) results were discordant. Hemolysis, lipemia and cold agglutinin were evaluated as possible reasons for the mismatch between hematocrit and hemoglobin values. First blood sample was slightly hemolysed. Redrawn sample without hemolysis or lipemia was analyzed but the mismatch became even more distinct (Hb: 104 g/L and HCT: 0.08 L/L). In this sample, the titration of the cold agglutinin was determined and found to be positive at 1:64 dilution ratios. After an incubation of the sample at 37°C for 2 hours, reversibility of agglutination was observed. We conclude that cold agglutinins may interfere with the analysis of erythrocyte and erythrocyte-related parameters (HCT, MCV, MCH and MCHC); however, Hb, leukocyte and platelet counts are not affected.

  5. Evaluation of the Efficiency of the Reticulocyte Hemoglobin Content on Diagnosis for Iron Deficiency Anemia in Chinese Adults

    Directory of Open Access Journals (Sweden)

    Jie Cai

    2017-05-01

    Full Text Available Our aim was to evaluate the cut-off value and efficiency of using reticulocyte hemoglobin content as a marker to diagnose iron deficiency anemia in Chinese adults. 140 adults who needed bone marrow aspiration for diagnosis at the hematology department of the Peking Union Medical College Hospital were enrolled according to the inclusive and exclusive criteria. Venous blood samples were collected to detect complete blood count, including hemoglobin, reticulocyte hemoglobin content, hematocrit, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, free erythrocyte protoporphyrin; iron indexes of serum ferritin, serum transferrin receptor, and unsaturated iron-binding capacity; and inflammation markers of C-reactive protein and α-acid glycoprotein. Bone marrow samples were obtained for the bone marrow iron staining, which was used as the standard for the evaluation of iron status in this study. Subjects were divided into three groups according to hemoglobin levels and bone marrow iron staining results: the IDA (iron deficiency anemia group, the NIDA (non-iron deficiency anemia group, and the control group. The differences of the above-mentioned indexes were compared among the three groups and the effect of inflammation was also considered. The cut-off value of reticulocyte hemoglobin content was determined by receiver operation curves. The IDA group (n = 56 had significantly lower reticulocyte hemoglobin content, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, and serum ferritin; and higher free erythrocyte protoporphyrin, unsaturated iron-binding capacity, and serum transferrin receptor (p < 0.05 compared with the NIDA group (n = 38 and control group (n = 46. Hematocrit, serum ferritin, and unsaturated iron-binding capacity were significantly affected by inflammation while reticulocyte hemoglobin content and other parameters were not. The cut-off value of reticulocyte hemoglobin content for

  6. Evaluation of the Efficiency of the Reticulocyte Hemoglobin Content on Diagnosis for Iron Deficiency Anemia in Chinese Adults.

    Science.gov (United States)

    Cai, Jie; Wu, Meng; Ren, Jie; Du, Yali; Long, Zhangbiao; Li, Guoxun; Han, Bing; Yang, Lichen

    2017-05-02

    Our aim was to evaluate the cut-off value and efficiency of using reticulocyte hemoglobin content as a marker to diagnose iron deficiency anemia in Chinese adults. 140 adults who needed bone marrow aspiration for diagnosis at the hematology department of the Peking Union Medical College Hospital were enrolled according to the inclusive and exclusive criteria. Venous blood samples were collected to detect complete blood count, including hemoglobin, reticulocyte hemoglobin content, hematocrit, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, free erythrocyte protoporphyrin; iron indexes of serum ferritin, serum transferrin receptor, and unsaturated iron-binding capacity; and inflammation markers of C-reactive protein and α-acid glycoprotein. Bone marrow samples were obtained for the bone marrow iron staining, which was used as the standard for the evaluation of iron status in this study. Subjects were divided into three groups according to hemoglobin levels and bone marrow iron staining results: the IDA (iron deficiency anemia) group, the NIDA (non-iron deficiency anemia) group, and the control group. The differences of the above-mentioned indexes were compared among the three groups and the effect of inflammation was also considered. The cut-off value of reticulocyte hemoglobin content was determined by receiver operation curves. The IDA group ( n = 56) had significantly lower reticulocyte hemoglobin content, mean cellular volume, corpuscular hemoglobin concentration, hemoglobin content, and serum ferritin; and higher free erythrocyte protoporphyrin, unsaturated iron-binding capacity, and serum transferrin receptor ( p iron-binding capacity were significantly affected by inflammation while reticulocyte hemoglobin content and other parameters were not. The cut-off value of reticulocyte hemoglobin content for diagnosing iron deficiency anemia was 27.2 pg, with a sensitivity of 87.5% and a specificity of 92.9%. The cut-off values for

  7. Evaluation of hematologic, blood gas, and select biochemical variables in ovine whole blood stored in CPDA-1 bags.

    Science.gov (United States)

    Sousa, Rejane S; Barrêto, Raimundo A; Sousa, Isadora K F; Chaves, Dowglish F; Soares, Herbert S; Barros, Isabella O; Minervino, Antonio H H; Ortolani, Enrico L

    2013-03-01

    The economic consequences from mortality of sheep after blood loss can be considerable. To date there are no reports addressing hematologic, blood gas, and biochemical changes in ovine blood stored in CPDA-1 bags. The aim of this study was to investigate hematologic, blood gas, and biochemical alterations resulting from storage of ovine blood in CPDA-1 bags to establish transfusion protocols in sheep. From each of 7 healthy 8-month-old sheep 450 mL of blood were collected into CPDA-1 bags and stored for 35 days in at 3-6°C. Samples were taken from the bags at days 0, 7, 14, 21, and 35. Whole blood was used to assess PCV, MCV, RBC count, pH, pO2 , pCO2 , and concentrations of bicarbonate, sodium, and lactate. Plasma was used to measure potassium, hemoglobin, and glucose concentrations. The PCV remained stable throughout the storage period, while plasma hemoglobin and MCV began to increase on days 7 and 21, respectively. The RBC count began to decrease on day 21. Blood pH decreased and pCO2 increased steadily throughout the storage period. Potassium concentration increased from 3.8 to 18.3 mmol/L on day 7 and remained high thereafter. In contrast, sodium concentration began to decrease on day 7. The results show that ovine blood undergoes hematologic, blood gas, and biochemical changes during storage. Further studies are required to establish RBC viability in CPDA-1 bags after a storage period of 35 days. © 2012 American Society for Veterinary Clinical Pathology.

  8. Determination of the thermodynamic state of concentrated hemoglobin solutions by means of small angle X-ray scattering

    International Nuclear Information System (INIS)

    Zinke, M.

    1979-01-01

    Exemplified by hemoglobin, the thermodynamic equilibrium properties of the dissolved macromolecular system could be determined solely from the small angle X-ray scattering of concentrated macromolecular solutions via the intermolecular structure of the dissolved macromolecules and their intermolecular potentials. From the scattering experiment on concentrated Hb solutions the concentration dependence of the following properties of the dissolved Hb system were determined: fluctuation, isothermic compressibility, internal energy, surface tension, and osmotic pressure. (author)

  9. Erythrocyte 2,3-DPG, PO2 50% and available O2 during the early post-natal fall in hemoglobin in rabbits.

    Science.gov (United States)

    Holter, P H; Halvorsen, S; Refsum, H E

    1982-09-01

    Erythrocyte 2,3-DPG, PO2 50%, whole blood hemoglobin and available O2, and fixed acid Bohr effect were studied during the first 10 days after birth in rapidly growing suckling rabbits. The post-natal fall in hemoglobin concentration was accompanied by a marked rise in erythrocyte 2,3-DPG and a gradual increase in PO2 50%. The rise in PO2 50% was sufficient to keep the available O2 of the blood unchanged throughout the observation period. The observations show that a 2,3-DPG mediated rise in PO2 50% very effectively contributes to maintenance of adequate tissue oxygenation during the post-natal fall in hemoglobin. The rise in 2,3-DPG and and PO2 50% may be due to the ordinary hypoxia-induced shift to the right of the hemoglobin O2 dissociation curve, as observed under other circumstances when blood hemoglobin is rapidly reduced, but the very marked rise in 2,3-DPG and the very low delta PO2 50%/delta 2,3-DPG ratio suggest that the rise may as well be due to hypoxia independent, pre-programmed processes. The fixed acid Bohr effect was essentially the same in newborn and adult rabbits, and was uninfluenced by large variations in 2,3-DPG.

  10. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Science.gov (United States)

    2010-04-01

    .... Measurements of free hemoglobin aid in the diagnosis of various hematologic disorders, such as sickle cell... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  11. Stability and Application of Reactive Nitrogen and Oxygen Species-Induced Hemoglobin Modifications in Dry Blood Spots As Analyzed by Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Chen, Hauh-Jyun Candy; Fan, Chih-Huang; Yang, Ya-Fen

    2016-12-19

    Dried blood spot (DBS) is an emerging microsampling technique for the bioanalysis of small molecules, including fatty acids, metabolites, drugs, and toxicants. DBS offers many advantages as a sample format including easy sample collection and cheap sample shipment. Hemoglobin adducts have been recognized as a suitable biomarker for monitoring chemical exposure. We previously reported that certain modified peptides in hemoglobin derived from reactive chlorine, nitrogen, and oxygen species are associated with factors including smoking, diabetes mellitus, and aging. However, the stability of these oxidation-induced modifications of hemoglobin remains unknown and whether they can be formed artifactually during storage of DBS. To answer these questions, globin extracted from the DBS cards was analyzed, and the stability of the modifications was evaluated. After storage of the DBS cards at 4 °C or room temperature up to 7 weeks, we isolated globin from a quarter of the spot every week. The extents of 11 sites and types of post-translational modifications (PTMs), including nitration and nitrosylation of tyrosine and oxidation of cysteine and methionine residues, in human hemoglobin were measured in the trypsin digest by nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) using selected reaction monitoring. The extents of all these PTMs are stable within 14 days when stored on DBS at room temperature and at 4 °C, while those from direct extraction of fresh blood are stable for at least 8 weeks when stored as an aqueous solution at -20 °C. Extraction of globin from a DBS card is of particular importance for hemolytic blood samples. To our knowledge, this is the first report on the stability of oxidative modifications of hemoglobin on DBSs, which are stable for 14 days under ambient conditions (room temperature, in air). Therefore, it is feasible and convenient to analyze these hemoglobin modifications from DBSs in studies

  12. Comparison of three noninvasive methods for hemoglobin screening of blood donors.

    Science.gov (United States)

    Ardin, Sergey; Störmer, Melanie; Radojska, Stela; Oustianskaia, Larissa; Hahn, Moritz; Gathof, Birgit S

    2015-02-01

    To prevent phlebotomy of anemic individuals and to ensure hemoglobin (Hb) content of the blood units, Hb screening of blood donors before donation is essential. Hb values are mostly evaluated by measurement of capillary blood obtained from fingerstick. Rapid noninvasive methods have recently become available and may be preferred by donors and staff. The aim of this study was to evaluate for the first time all different noninvasive methods for Hb screening. Blood donors were screened for Hb levels in three different trials using three different noninvasive methods (Haemospect [MBR Optical Systems GmbH & Co. KG], NBM 200 [LMB Technology GmbH], Pronto-7 [Masimo Europe Ltd]) in comparison to the established fingerstick method (CompoLab Hb [Fresenius Kabi GmbH]) and to levels obtained from venous samples on a cell counter (Sysmex [Sysmex Europe GmbH]) as reference. The usability of the noninvasive methods was assessed with an especially developed survey. Technical failures occurred by using the Pronto-7 due to nail polish, skin color, or ambient light. The NBM 200 also showed a high sensitivity to ambient light and noticeably lower Hb levels for women than obtained from the Sysmex. The statistical analysis showed the following bias and standard deviation of differences of all methods in comparison to the venous results: Haemospect, -0.22 ± 1.24; NBM, 200 -0.12 ± 1.14; Pronto-7, -0.50 ± 0.99; and CompoLab Hb, -0.53 ± 0.81. Noninvasive Hb tests represent an attractive alternative by eliminating pain and reducing risks of blood contamination. The main problem for generating reliable results seems to be preanalytical variability in sampling. Despite the sensitivity to environmental stress, all methods are suitable for Hb measurement. © 2014 AABB.

  13. Long-Term Stored Hemoglobin-Vesicles, a Cellular Type of Hemoglobin-Based Oxygen Carrier, Has Resuscitative Effects Comparable to That for Fresh Red Blood Cells in a Rat Model with Massive Hemorrhage without Post-Transfusion Lung Injury.

    Directory of Open Access Journals (Sweden)

    Masahiro Tokuno

    Full Text Available Hemoglobin-vesicles (HbV, encapsulating highly concentrated human hemoglobin in liposomes, were developed as a substitute for red blood cells (RBC and their safety and efficacy in transfusion therapy has been confirmed in previous studies. Although HbV suspensions are structurally and physicochemically stabile for least 1-year at room temperature, based on in vitro experiments, the issue of whether the use of long-term stored HbV after a massive hemorrhage can be effective in resuscitations without adverse, post-transfusion effects remains to be clarified. We report herein on a comparison of the systemic response and the induction of organ injuries in hemorrhagic shock model rats resuscitated using 1-year-stored HbV, freshly packed RBC (PRBC-0 and by 28-day-stored packed RBC (PRBC-28. The six-hour mortality after resuscitation was not significantly different among the groups. Arterial blood pressure and blood gas parameters revealed that, using HbV, recovery from the shock state was comparable to that when PRBC-0 was used. Although no significant change was observed in serum parameters reflecting liver and kidney injuries at 6 hours after resuscitation among the three resuscitation groups, results based on Evans Blue and protein leakage in bronchoalveolar lavage fluid, the lung wet/dry weight ratio and histopathological findings indicated that HbV as well as PRBC-0 was less predisposed to result in a post-transfusion lung injury than PRBC-28, as evidenced by low levels of myeloperoxidase accumulation and subsequent oxidative damage in the lung. The findings reported herein indicate that 1-year-stored HbV can effectively function as a resuscitative fluid without the induction of post-transfused lung injury and that it is comparable to fresh PRBC, suggesting that HbV is a promising RBC substitute with a long shelf-life.

  14. Purification, characterization and sequence analyses of the extracellular giant hemoglobin from Oligobrachia mashikoi

    OpenAIRE

    Nakagawa, Taro; Onoda, Seiko; Kanemori, Masaaki; Sasayama, Yuichi; Fukumori, Yoshihiro

    2005-01-01

    We purified an extracellular hemoglobin with the molecular mass of ca. 440 kDa from the whole homogenates of Oligobrachia mashikoi (phylum Pogonophora) by a one-step gel-filtration. The preparation was pure to be crystallized. The P50 values of the hemoglobin and the fresh blood prepared from O. mashikoi were about 0.82 Torr and 0.9 Torr, respectively, which were much lower than the P50 value of human hemoglobin. However, the n values of the hemoglobin and the blood were about 1.2 and 1.1, re...

  15. Biophysical Monitoring and dose response characteristics of irradiated hemoglobin

    International Nuclear Information System (INIS)

    Elshemey, W.M; Selim, N.S.; Desouky, O.

    2003-01-01

    The present work aims to move a step forward towards a deeper understanding of the scattering of x-ray, from lyophilized biological samples. Comparative study has been performed using LAXS and UV-visible spectrophotometry for monitoring the dose response characteristics of the hemoglobin molecule of irradiated blood. Blood samples were irradiated at doses ranging from 5 up to 100 Gy. Diluted hemoglobin solution was scanned in the UV- visible range (200-700 nm), and lyophilized hemoglobin was prepared for LAXS measurement. The radiation-induced changes in the hemoglobin structure have been evaluated. The LAXS profile of hemoglobin molecule is characterized by the presence of two peaks in the forward direction of scattering. These peaks were found to be sensitive to the variations in the molecular structure of a given sample. The obtained results suggest that the 1 s t peak, recorded at 4.65 o , is sensitive to the tertiary and quaternary structure of the globin part, while the major peak, recorded at 10.5 o , appeared to be related to its primary and secondary structure

  16. A method comparison study between two hemoglobinometer models (Hemocue Hb 301 and Hb 201+) to measure hemoglobin concentrations and estimate anemia prevalence among women in Preah Vihear, Cambodia.

    Science.gov (United States)

    Rappaport, A I; Karakochuk, C D; Whitfield, K C; Kheang, K M; Green, T J

    2017-02-01

    Hemoglobin (Hb) concentration is often measured in global health and nutrition surveys to determine anemia prevalence using a portable hemoglobinometer such as the Hemocue® Hb 201+. More recently, a newer model was released (Hemocue Hb 301) utilizing slightly different methods to measure Hb as compared to the older model. The objective was to measure bias and concordance between Hb concentrations using the Hemocue Hb 301 and Hb 201+ models in a rural field setting. Hemoglobin (Hb) concentration was measured using one finger prick of blood (approximately 10 μL) from 175 Cambodian women (18-49 years) using three Hemocue Hb 201+ and three Hb 301 machines. Bias and concordance were measured and plotted. Overall, mean ± SD Hb concentration was 116 ± 13 g/L using the Hb 201+ and 118 ± 12 g/L using the Hb 301; and anemia prevalence (Hb < 120 g/L) was 58% (n = 102) and 58% (n = 101), respectively. Overall bias ± SD was 2.0 ± 10.5 g/L and concordance (95% CI) was 0.63 (0.54, 0.72). Despite the 2 g/L bias detected between models, anemia prevalence was very similar in both models. The two models measured anemia prevalence comparably in this population of women in rural Cambodia. © 2016 John Wiley & Sons Ltd.

  17. Individualized anemia management reduces hemoglobin variability in hemodialysis patients.

    Science.gov (United States)

    Gaweda, Adam E; Aronoff, George R; Jacobs, Alfred A; Rai, Shesh N; Brier, Michael E

    2014-01-01

    One-size-fits-all protocol-based approaches to anemia management with erythropoiesis-stimulating agents (ESAs) may result in undesired patterns of hemoglobin variability. In this single-center, double-blind, randomized controlled trial, we tested the hypothesis that individualized dosing of ESA improves hemoglobin variability over a standard population-based approach. We enrolled 62 hemodialysis patients and followed them over a 12-month period. Patients were randomly assigned to receive ESA doses guided by the Smart Anemia Manager algorithm (treatment) or by a standard protocol (control). Dose recommendations, performed on a monthly basis, were validated by an expert physician anemia manager. The primary outcome was the percentage of hemoglobin concentrations between 10 and 12 g/dl over the follow-up period. A total of 258 of 356 (72.5%) hemoglobin concentrations were between 10 and 12 g/dl in the treatment group, compared with 208 of 336 (61.9%) in the control group; 42 (11.8%) hemoglobin concentrations were hemoglobin concentrations were >12 g/dl in the treatment group compared with 46 (13.4%) in the control group. The median ESA dosage per patient was 2000 IU/wk in both groups. Five participants received 6 transfusions (21 U) in the treatment group, compared with 8 participants and 13 transfusions (31 U) in the control group. These results suggest that individualized ESA dosing decreases total hemoglobin variability compared with a population protocol-based approach. As hemoglobin levels are declining in hemodialysis patients, decreasing hemoglobin variability may help reduce the risk of transfusions in this population.

  18. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Science.gov (United States)

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  19. Estimation of Melanin and Hemoglobin Using Spectral Reflectance Images Reconstructed from a Digital RGB Image by the Wiener Estimation Method

    Directory of Open Access Journals (Sweden)

    Yoshihisa Aizu

    2013-06-01

    Full Text Available A multi-spectral diffuse reflectance imaging method based on a single snap shot of Red-Green-Blue images acquired with the exposure time of 65 ms (15 fps was investigated for estimating melanin concentration, blood concentration, and oxygen saturation in human skin tissue. The technique utilizes the Wiener estimation method to deduce spectral reflectance images instantaneously from an RGB image. Using the resultant absorbance spectrum as a response variable and the extinction coefficients of melanin, oxygenated hemoglobin and deoxygenated hemoglobin as predictor variables, multiple regression analysis provides regression coefficients. Concentrations of melanin and total blood are then determined from the regression coefficients using conversion vectors that are numerically deduced in advance by the Monte Carlo simulations for light transport in skin. Oxygen saturation is obtained directly from the regression coefficients. Experiments with a tissue-like agar gel phantom validated the method. In vivo experiments on fingers during upper limb occlusion demonstrated the ability of the method to evaluate physiological reactions of human skin.

  20. The effects of 2,3-diphosphoglycerate, adenosine triphosphate, and glycosylated hemoglobin on the hemoglobin-oxygen affinity of diabetic patients

    Directory of Open Access Journals (Sweden)

    Castilho E.M.

    2003-01-01

    Full Text Available The position of the oxygen dissociation curve (ODC is modulated by 2,3-diphosphoglycerate (2,3-DPG. Decreases in 2,3-DPG concentration within the red cell shift the curve to the left, whereas increases in concentration cause a shift to the right of the ODC. Some earlier studies on diabetic patients have reported that insulin treatment may reduce the red cell concentrations of 2,3-DPG, causing a shift of the ODC to the left, but the reports are contradictory. Three groups were compared in the present study: 1 nondiabetic control individuals (N = 19; 2 insulin-dependent diabetes mellitus (IDDM patients (on insulin treatment (N = 19; 3 non-insulin-dependent diabetes mellitus (NIDDM patients using oral hypoglycemic agents and no insulin treatment (N = 22. The overall position of the ODC was the same for the three groups despite an increase of the glycosylated hemoglobin fraction that was expected to shift the ODC to the left in both groups of diabetic patients (HbA1c: control, 4.6%; IDDM, 10.5%; NIDDM, 9.0%. In IDDM patients, the effect of the glycosylated hemoglobin fraction on the position of the ODC appeared to be counterbalanced by small though statistically significant increases in 2,3-DPG concentration from 2.05 (control to 2.45 µmol/ml blood (IDDM. Though not statistically significant, an increase of 2,3-DPG also occurred in NIDDM patients, while red cell ATP levels were the same for all groups. The positions of the ODC were the same for control subjects, IDDM and NIDDM patients. Thus, the PO2 at 50% hemoglobin-oxygen saturation was 26.8, 28.2 and 28.5 mmHg for control, IDDM and NIDDM, respectively. In conclusion, our data question the idea of adverse side effects of insulin treatment on oxygen transport. In other words, the shift to the left reported by others to be caused by insulin treatment was not detected.

  1. The effects of 2,3-diphosphoglycerate, adenosine triphosphate, and glycosylated hemoglobin on the hemoglobin-oxygen affinity of diabetic patients.

    Science.gov (United States)

    Castilho, E M; Glass, M L; Manço, J C

    2003-06-01

    The position of the oxygen dissociation curve (ODC) is modulated by 2,3-diphosphoglycerate (2,3-DPG). Decreases in 2,3-DPG concentration within the red cell shift the curve to the left, whereas increases in concentration cause a shift to the right of the ODC. Some earlier studies on diabetic patients have reported that insulin treatment may reduce the red cell concentrations of 2,3-DPG, causing a shift of the ODC to the left, but the reports are contradictory. Three groups were compared in the present study: 1) nondiabetic control individuals (N = 19); 2) insulin-dependent diabetes mellitus (IDDM) patients (on insulin treatment) (N = 19); 3) non-insulin-dependent diabetes mellitus (NIDDM) patients using oral hypoglycemic agents and no insulin treatment (N = 22). The overall position of the ODC was the same for the three groups despite an increase of the glycosylated hemoglobin fraction that was expected to shift the ODC to the left in both groups of diabetic patients (HbA1c: control, 4.6%; IDDM, 10.5%; NIDDM, 9.0%). In IDDM patients, the effect of the glycosylated hemoglobin fraction on the position of the ODC appeared to be counterbalanced by small though statistically significant increases in 2,3-DPG concentration from 2.05 (control) to 2.45 mol/ml blood (IDDM). Though not statistically significant, an increase of 2,3-DPG also occurred in NIDDM patients, while red cell ATP levels were the same for all groups. The positions of the ODC were the same for control subjects, IDDM and NIDDM patients. Thus, the PO2 at 50% hemoglobin-oxygen saturation was 26.8, 28.2 and 28.5 mmHg for control, IDDM and NIDDM, respectively. In conclusion, our data question the idea of adverse side effects of insulin treatment on oxygen transport. In other words, the shift to the left reported by others to be caused by insulin treatment was not detected.

  2. [Optimization of trehalose loading in red blood cells before freeze-drying].

    Science.gov (United States)

    Zhuang, Yuan; Liu, Jing-Han; Ouyang, Xi-Lin; Chen, Lin-Feng; Che, Ji

    2007-04-01

    The key points for better protection of trehalose in freeze-drying red blood cells (RBCs) are to resolve non-osmosis of trehalose to red blood cells and to make cytoplasmic trehalose to reach effective concentration. This study was aimed to investigate the regularity of loading RBCs with trehalose, screen out optimal loading condition and evaluate the effect of trehalose on physico-chemical parameters of RBCs during the period of loading. The cytoplasmic trehalose concentration in red blood cells, free hemoglobin and ATP level were determined at different incubation temperatures (4, 22 and 37 degrees C), different trehaolse concentrations (0, 200, 400, 600, 800 and 1000 mmol/L) and different incubation times (2, 4, 6, 8 and 10 hours), the cytoplasmic trehalose, free hemoglobin (FHb), hemoglobin (Hb) and mean corpuscular volume (MCV) in fresh RBCs and RBCs stored for 72 hours at 4 degrees C were compared, when loading condition was ensured. The results showed that with increase of incubation temperature, time and extracellular trehalose concentration, the loading of trehalose in RBCs also increased. Under the optimal loading condition, cytoplasmic trehalose concentration and free hemoglobin level of fresh RBCs and RBCs stored for 72 hours at 4 degrees C were 65.505 +/- 6.314 mmol/L, 66.2 +/- 5.002 mmol/L and 6.567 +/- 2.568 g/L, 16.168 +/- 3.922 g/L respectively. It is concluded that the most optimal condition of loading trehalose is that fresh RBCs incubate in 800 mmol/L trehalose solution for 8 hours at 37 degrees C. This condition can result in a efficient cytoplasmic trehalose concentration. The study provides an important basis for long-term preservation of RBCs.

  3. Hemoglobin levels in normal Filipino pregnant women.

    Science.gov (United States)

    Kuizon, M D; Natera, M G; Ancheta, L P; Platon, T P; Reyes, G D; Macapinlac, M P

    1981-09-01

    The hemoglobin concentrations during pregnancy in Filipinos belonging to the upper income group, who were prescribed 105 mg elemental iron daily, and who had acceptable levels of transferrin saturation, were examined in an attempt to define normal levels. The hemoglobin concentrations for each trimester followed a Gaussian distribution. The hemoglobin values equal to the mean minus one standard deviation were 11.4 gm/dl for the first trimester and 10.4 gm/dl for the second and third trimesters. Using these values as the lower limits of normal, in one group of pregnant women the prevalence of anemia during the last two trimesters was found lower than that obtained when WHO levels for normal were used. Groups of women with hemoglobin of 10.4 to 10.9 gm/dl (classified anemic by WHO criteria but normal in the present study) and those with 11.0 gm/dl and above could not be distinguished on the basis of their serum ferritin levels nor on the degree of decrease in their hemoglobin concentration during pregnancy. Many subjects in both groups, however, had serum ferritin levels less than 12 ng/ml which indicate poor iron stores. It might be desirable in future studies to determine the hemoglobin cut-off point that will delineate subjects who are both non-anemic and adequate in iron stores using serum ferritin levels as criterion for the latter.

  4. Effect of testosterone administration on lead induced zincprotoporphyrin in blood concentration in castrated male rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Wibowo, A.A.E.; Zielhuis, R.L.

    1981-11-01

    The influence of testosterone propionate on the concentration of zincprotoporphyrin in blood (ZPP) of castrated lead treated rabbits was investigated. The experimental design allowed comparison of the relative ZPP increase (RZI) in testosterone treated and non testosterone treated rabbits. Testosterone was administered by subcutaneous injection of 3 mg/kg body weight/day for 7 consecutive days directly prior to the lead exposure, which was performed by subcutaneous injection of 0.50 mg lead acetate/kg body weight, three times a week for 7 weeks. No effect was found on the hemoglobin concentration (Hb) and hematocrit (Ht) and on the increase of body weight during the experiment. But the increase of RZI in the non testosterone treated rabbits was significantly steeper and earlier than in the testosterone treated group. The possible consequences of the findings had been further commented on.

  5. Alteration of Blood Parameters and Histoarchitecture of Liver and Kidney of Silver Barb after Chronic Exposure to Quinalphos

    Directory of Open Access Journals (Sweden)

    Golam Mohammod Mostakim

    2015-01-01

    Full Text Available Quinalphos (QP is commonly used for pest control in the agricultural fields surrounding freshwater reservoirs. This study was conducted to evaluate the chronic toxicity of this pesticide on blood parameters and some organs of silver barb, Barbonymus gonionotus. Fish were exposed to two sublethal concentrations, 0.47 ppm and 0.94 ppm, of QP for a period of 28 days. All the blood parameters (red blood cell, hematocrit, and hemoglobin and blood glucose except for white blood cells decreased with increasing concentration of toxicant and become significantly lower (p<0.05 at higher concentration when compared with control. The derived hematological indices of mean corpuscular volume, mean corpuscular hemoglobin, and mean corpuscular hemoglobin concentration were equally altered compared to control. Histoarchitectural changes of liver and kidney were observed after exposure to the QP. Hypertrophy of hepatocytes, mild to severe necrosis, ruptured central vein, and vacuolation were observed in the liver of treated groups. Highly degenerated kidney tubules and hematopoietic tissue, degeneration of renal corpuscle, vacuolization, and necrosis were evident in the kidney of treated groups. In conclusion, chronic exposure to QP at sublethal concentrations induced hematological and histological alterations in silver barb and offers a simple tool to evaluate toxicity derived alterations.

  6. Structural and Mechanistic Insights into Hemoglobin-catalyzed Hydrogen Sulfide Oxidation and the Fate of Polysulfide Products

    Energy Technology Data Exchange (ETDEWEB)

    Vitvitsky, Victor; Yadav, Pramod K.; An, Sojin; Seravalli, Javier; Cho, Uhn-Soo; Banerjee, Ruma (Michigan-Med); (UNL)

    2017-02-17

    Hydrogen sulfide is a cardioprotective signaling molecule but is toxic at elevated concentrations. Red blood cells can synthesize H2S but, lacking organelles, cannot dispose of H2S via the mitochondrial sulfide oxidation pathway. We have recently shown that at high sulfide concentrations, ferric hemoglobin oxidizes H2S to a mixture of thiosulfate and iron-bound polysulfides in which the latter species predominates. Here, we report the crystal structure of human hemoglobin containing low spin ferric sulfide, the first intermediate in heme-catalyzed sulfide oxidation. The structure provides molecular insights into why sulfide is susceptible to oxidation in human hemoglobin but is stabilized against it in HbI, a specialized sulfide-carrying hemoglobin from a mollusk adapted to life in a sulfide-rich environment. We have also captured a second sulfide bound at a postulated ligand entry/exit site in the α-subunit of hemoglobin, which, to the best of our knowledge, represents the first direct evidence for this site being used to access the heme iron. Hydrodisulfide, a postulated intermediate at the junction between thiosulfate and polysulfide formation, coordinates ferric hemoglobin and, in the presence of air, generated thiosulfate. At low sulfide/heme iron ratios, the product distribution between thiosulfate and iron-bound polysulfides was approximately equal. The iron-bound polysulfides were unstable at physiological glutathione concentrations and were reduced with concomitant formation of glutathione persulfide, glutathione disulfide, and H2S. Hence, although polysulfides are unlikely to be stable in the reducing intracellular milieu, glutathione persulfide could serve as a persulfide donor for protein persulfidation, a posttranslational modification by which H2S is postulated to signal.

  7. Erythrocyte enrichment in hematopoietic progenitor cell cultures based on magnetic susceptibility of the hemoglobin.

    Directory of Open Access Journals (Sweden)

    Xiaoxia Jin

    Full Text Available Using novel media formulations, it has been demonstrated that human placenta and umbilical cord blood-derived CD34+ cells can be expanded and differentiated into erythroid cells with high efficiency. However, obtaining mature and functional erythrocytes from the immature cell cultures with high purity and in an efficient manner remains a significant challenge. A distinguishing feature of a reticulocyte and maturing erythrocyte is the increasing concentration of hemoglobin and decreasing cell volume that results in increased cell magnetophoretic mobility (MM when exposed to high magnetic fields and gradients, under anoxic conditions. Taking advantage of these initial observations, we studied a noninvasive (label-free magnetic separation and analysis process to enrich and identify cultured functional erythrocytes. In addition to the magnetic cell separation and cell motion analysis in the magnetic field, the cell cultures were characterized for cell sedimentation rate, cell volume distributions using differential interference microscopy, immunophenotyping (glycophorin A, hemoglobin concentration and shear-induced deformability (elongation index, EI, by ektacytometry to test for mature erythrocyte attributes. A commercial, packed column high-gradient magnetic separator (HGMS was used for magnetic separation. The magnetically enriched fraction comprised 80% of the maturing cells (predominantly reticulocytes that showed near 70% overlap of EI with the reference cord blood-derived RBC and over 50% overlap with the adult donor RBCs. The results demonstrate feasibility of label-free magnetic enrichment of erythrocyte fraction of CD34+ progenitor-derived cultures based on the presence of paramagnetic hemoglobin in the maturing erythrocytes.

  8. Aspartic protease activities of schistosomes cleave mammalian hemoglobins in a host-specific manner

    Directory of Open Access Journals (Sweden)

    Jeffrey W Koehler

    2007-02-01

    Full Text Available We examined the efficiency of digestion of hemoglobin from four mammalian species, human, cow, sheep, and horse by acidic extracts of mixed sex adults of Schistosoma japonicum and S. mansoni. Activity ascribable to aspartic protease(s from S. japonicum and S. mansoni cleaved human hemoglobin. In addition, aspartic protease activities from S. japonicum cleaved hemoglobin from bovine, sheep, and horse blood more efficiently than did the activity from extracts of S. mansoni. These findings support the hypothesis that substrate specificity of hemoglobin-degrading proteases employed by blood feeding helminth parasites influences parasite host species range; differences in amino acid sequences in key sites of the parasite proteases interact less or more efficiently with the hemoglobins of permissive or non-permissive hosts.

  9. Toxic effects of zinc from trout farm sediments on ATP, protein, and hemoglobin concentrations of Limnodrilus hoffmeisteri.

    Science.gov (United States)

    Martinez-Tabche, L; Gutiérrez Cabrera, I; Gómez Oliván, L; Galar Martinez, M; Germán Faz, C

    2000-04-14

    Zinc (Zn) is a nutritionally essential metal, and deficiency results in severe health consequences to aquatic organisms. In this study toxicity data for Limnodrilus hoffmeisteri produced by Zn in systems using three natural sediments (trout farms: El Oyamel, El Truchón, and El Potrero) are presented. Hemoglobin, adenosine triphosphate (ATP), and protein concentrations were measured in L. hoffmeisteri exposed to spiked sediments, as indicators of exposure. Physicochemical characteristics of water and sediments were also considered. Zn concentrations were measured in water and sediment. El Oyamel, El Truchón, and El Potrero pond sediments did not have similar physicochemical characteristics. Zn concentrations of water obtained from the rustic ponds were near 0.4575 mg/L; however, this metal was always found to be higher in the sediments (0.0271-0.9754 mg/kg). The bioassay with worms demonstrated that pond sediments from El Oyamel, El Potrero, and El Truchón produced toxicity since ATP and protein concentrations were low compared to controls (organisms without metal). All spiked sediments had a significant reduction effect on ATP, protein, and hemoglobin concentrations. This investigation clearly shows that sediments of El Truchón, El Oyamel, and El Potrero possess toxicity potential. These results suggest the usefulness of these bioassays to evaluate the toxicity of sediments polluted with heavy metals.

  10. Personal PM2.5 exposure and markers of oxidative stress in blood

    DEFF Research Database (Denmark)

    Sørensen, Mette; Daneshvar, Bahram; Hansen, Max

    2003-01-01

    Ambient particulate air pollution assessed as outdoor concentrations of particulate matter less than or equal to 2.5 micro m in diameter (PM(2.5)) in urban background has been associated with cardiovascular diseases at the population level. However, the significance of individual exposure...... and the involved mechanisms remain uncertain. We measured personal PM(2.5) and carbon black exposure in 50 students four times in 1 year and analyzed blood samples for markers of protein and lipid oxidation, for red blood cell (RBC) and platelet counts, and for concentrations of hemoglobin and fibrinogen. We...... analyzed protein oxidation in terms of gamma-glutamyl semialdehyde in hemoglobin (HBGGS) and 2-aminoadipic semialdehyde in hemoglobin (HBAAS) and plasma proteins (PLAAS), and lipid peroxidation was measured as malondialdehyde (MDA) in plasma. Median exposures were 16.1 micro g/m(3) for personal PM(2.5...

  11. Personal PM2.5 exposure and markers of oxidative stress in blood

    DEFF Research Database (Denmark)

    Sørensen, Mettte; Daneshvar, Bahram; Hansen, Max

    2003-01-01

    wAmbient particulate air pollution assessed as outdoor concentrations of particulate matter less than or equal to 2.5 mum in diameter (PM2.5) in urban background has been associated with cardiovascular diseases at the population level. However, the significance of individual exposure...... and the involved mechanisms remain uncertain. We measured personal PM2.5 and carbon black exposure in 50 students four times in 1 year and analyzed blood samples for markers of protein and lipid oxidation, for red blood cell (RBC) and platelet counts, and for concentrations of hemoglobin and fibrinogen. We...... analyzed protein oxidation in terms of gamma-glutamyl semialdehyde in hemoglobin (HBGGS) and 2-aminoadipic semialdehyde in hemoglobin (HBAAS) and plasma proteins (PLAAS), and lipid peroxidation was measured as malondialdehyde (MDA) in plasma. Median exposures were 16.1 mug/m(3) for personal PM2.5 exposure...

  12. The Effect of Red Fruit's (Pandanus conoideus Extract to Eritrocytes, Hemoglobin, PCV and TPP Concentrations of Mice (Mus musculus Infected by Toxoplasma gondii

    Directory of Open Access Journals (Sweden)

    Anis Dwi Utami

    2014-11-01

    Full Text Available Toxoplasmosis is a zoonotic parasites caused by Toxoplasma gondii. The red fruit’s extract contains tocopherol and betacarotene as antioxidant and it can repair the bodies immune system. This research was aimed to study the effect of red fruit’s extract to erithrocytes, hemoglobine, the values of PCV and TPP concentration of mice infected with T. gondii, so that the red fruit extract can be used as alternative herbal medicine for eliminating Toxoplasmosis. 15 of Balb/C mice, male, three months, 30 gr of body weight were used as experimental animals. The mice were then devided into three groups. Group I was a control, group II  was tachyzoite infected and group III was tachyzoite infected and given red fruit’s extract. Group III given red fruit’s extract on first day with 0,53 g/kg BW/mice/day. Mice in group II and III were infected by injection Toxoplasma gondii tachyziote 1x103 a mice intraperitoneally. The blood sample was taken from five mice in each group at 7th and 12th day pass through cantus medialis. The blood was examinated in Clinical Pathology Laboratory, Faculty of Veterinary Medicine, Gadjah Mada University. Data were analyzed by using Factorial 2 x 3. The result showed no significant difference (P>0,05 in hemoglobin, and PCV’s value between groups I, II and III before and after infection of T. gondii’s tachyzoite. The TPP’s value between groups I, II and III before and after infection of T. gondii’s tachyzoite was significantly difference (P<0,05.

  13. A comparative study of fasting, postprandial blood glucose and glycated hemoglobin for diagnosing diabetes mellitus in staff members of MMIMSR, Mullana, Ambala

    Directory of Open Access Journals (Sweden)

    Qazi Najeeb

    2015-01-01

    Full Text Available Introduction: For decades, the diagnosis of diabetes mellitus was based on blood glucose criteria, either the fasting blood glucose (FBG or a 2-h value in the 75-g oral glucose tolerance test. In 2009, an International Expert Committee that included representatives of the American Diabetes Association (ADA, International Diabetes Federation and European Association for the Study of Diabetes recommended the use of the HbA1c test to diagnose diabetes with a threshold of ≥6.5% and this criterion was finally adopted by ADA in 2010. Hence, the study was undertaken to evaluate the predictive efficacy of glycated hemoglobin as a diagnostic tool for diabetes mellitus and to identify individuals at risk of developing diabetes mellitus using Indian Diabetes Risk Score (IDRS. Materials and Methods: This cross-sectional study was conducted on the staff members of the Maharishi Markandeshwar Institute of Medical Science and Research, Mullana, Ambala, Haryana, India. Out of the total 800 staff members, 200 staff members were included in the study (88 faculty members, 37 staff nurses, 12 laboratory technicians, 25 clerical staff, 38 class IV selected by systemic random sampling. Every fifth member on the list was included in the sample. After obtaining the data, it was coded and analyzed using multivariate logistic regression analysis. Receiver operating characteristics curve analysis was used to predict the sensitivity, specificity, positivity, negativity and overall accuracy of a diagnostic test. A two-tailed test P < 0.05 was considered as statistically significant. Data was analyzed using SPSS 20 (IBM, Chicago, USA. Results: Out of 200 subjects, 19.5% were labeled diabetic using FBG, 23% by postprandial blood glucose (PPBG and 38.5% by using glycated hemoglobin according to ADA guidelines. A total of 62% had high-risk score out of which majority belonged to group-I (faculty followed by group-II (nursing staff and group-IV (clerical staff. With the

  14. Cost-effective and rapid blood analysis on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  15. The refractive index of human hemoglobin in the visible range

    International Nuclear Information System (INIS)

    Zhernovaya, O; Tuchin, V; Sydoruk, O; Douplik, A

    2011-01-01

    Because the refractive index of hemoglobin in the visible range is sensitive to the hemoglobin concentration, optical investigations of hemoglobin are important for medical diagnostics and treatment. Direct measurements of the refractive index are, however, challenging; few such measurements have previously been reported, especially in a wide wavelength range. We directly measured the refractive index of human deoxygenated and oxygenated hemoglobin for nine wavelengths between 400 and 700 nm for the hemoglobin concentrations up to 140 g l -1 . This paper analyzes the results and suggests a set of model functions to calculate the refractive index depending on the concentration. At all wavelengths, the measured values of the refractive index depended on the concentration linearly. Analyzing the slope of the lines, we determined the specific refraction increments, derived a set of model functions for the refractive index depending on the concentration, and compared our results with those available in the literature. Based on the model functions, we further calculated the refractive index at the physiological concentration within the erythrocytes of 320 g l -1 . The results can be used to calculate the refractive index in the visible range for arbitrary concentrations provided that the refractive indices depend on the concentration linearly.

  16. In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy.

    Science.gov (United States)

    Chen, Zhongjiang; Yang, Sihua; Xing, Da

    2012-08-15

    A method for noninvasively detecting hemoglobin oxygen saturation (SO2) and carboxyhemoglobin saturation (SCO) in subcutaneous microvasculature with multiwavelength photoacoustic microscopy is presented. Blood samples mixed with different concentrations of carboxyhemoglobin were used to test the feasibility and accuracy of photoacoustic microscopy compared with the blood-gas analyzer. Moreover, fixed-point detection of SO2 and SCO in mouse ear was obtained, and the changes from normoxia to carbon monoxide hypoxia were dynamically monitored in vivo. Experimental results demonstrate that multiwavelength photoacoustic microscopy can detect SO2 and SCO, which has future potential clinical applications.

  17. Interaction of thyroid hormone and hemoglobin: nature of the interaction and effect of hemoglobin on thyroid hormone radioimmunoassay

    International Nuclear Information System (INIS)

    Davis, P.J.; Yoshida, K.; Schoenl, M.

    1980-01-01

    Gel filtration of human erythrocyte (RBC) lysate incubated with labeled thyroxine (Tu) or triiodothyronine (Tt) revealed co-elution of a major iodothyronine-binding fraction (R-2) and hemoglobin. Solutions of purified human hemoglobin and Tt also showed co-elution of hormone and hemoglobin. Because hematin and protoporphyrin were shown to bind labeled Tt, the oxygen-binding site on hemoglobin was excluded as the site of iodothyronine-hemoglobin interaction. Analysis of hormone binding by heme and globin moieties showed Tt binding to be limited to the heme fraction. Addition of excess unlabeled Tt to hemoglobin or heme incubated with labeled Tt indicated 75% to 90% of hormone binding was poorly dissociable. These observations suggested that the presence of hemoglobin in RBC lysate or in serum could influence the measurement of Tu and Tt by specific radioimmunoassay (RIA). Subsequent studies of the addition to serum of human hemoglobin revealed a significant reduction in Tt and Tu detectable by RIA in the presence of this protein. The effect was influenced by the concentration of hemoglobin and by duration and temperature of incubations of hemoglobin and serum prior to RIA

  18. Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC for up to 7 days

    Directory of Open Access Journals (Sweden)

    Mahmoud Mohammed Sirdah

    2013-01-01

    Full Text Available BACKGROUND: The complete blood count is one of the most common routine tests. This study aimed to evaluate possible effects of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC over seven days. METHODS: Venous blood samples of 25 healthy males were distributed into two sets of tubes with each set of four tubes containing 50 µL of solutions with zero, 2.5 g/L, 5 g/L, 10 g/L taurine. The tubes were kept at room temperature or at 4ºC. Complete blood counts were performed on seven successive days. The mean percentage changes [Δ = (mean value - mean baseline value / mean baseline value x 100] were calculated and compared. RESULTS: Complete blood count parameters exhibited different patterns of behavior which were affected by the storage temperature, time and taurine concentration. Taurine at room temperature significantly enhancedthe stability of: the platelet count over seven days (Δ7 at 2.5, 5 and 10 g/L taurine were 5.45, 6.11, and 5.80 x 10(9 cells/L, respectively; the red blood cell count over five days (Δ5 at 2.5, 5 and 10 g/L taurine were 1.59, 2.79, and 1.98 x 10(12 cells/L, respectively; mean corpuscular hemoglobin over five days (Δ5 at 2.5, 5 and 10 g/L taurine were -0.91,-1.52 and -0.84 fl respectively; and red cell distribution width over two days (Δ2 at 2.5, 5 and 10 g/L taurine were 0.90%, 1.30% and -0.1%, respectively. No additional stabilizing effects of taurine were reported for the mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, hematocrit and hemoglobin, while it negatively affected the white blood cell stability. CONCLUSION: Complete blood count parameters exhibited variable stability patterns in respect to temperature, time and taurine concentration.

  19. Reticulocyte hemoglobin content (MCHr) in the detection of iron deficiency.

    Science.gov (United States)

    Urrechaga Igartua, Eloísa; Hoffmann, Johannes J M L; Izquierdo-Álvarez, Silvia; Escanero, Jesús F

    2017-09-01

    Blood hemoglobin (Hb) concentration within the reference interval does not exclude iron deficiency (ID): individuals with normal stores lose iron during a long period before their Hb falls below of the level that is defined as anemia. The process entails a decrease of storage iron, shown by serum ferritin below reference range, followed by iron depletion, eventually leading to iron restricted erythropoiesis; consequence of an imbalance between erythropoietic iron requirements and too low supply is a reduction of Hb synthesis in reticulocytes. We study the potential utility of mean reticulocyte hemoglobin content (MCHr), reported by CELL-DYN Sapphire (Abbott Diagnostics) analyzer, in the detection of ID in non-anemic adults. 207 patients with Hb within the reference range were enrolled. ID was defined as Hb>120g/L (women), >130g/L (men) and serum ferritin iron deficient adults. Copyright © 2016 Elsevier GmbH. All rights reserved.

  20. Reductions in red blood cell 2,3-diphosphoglycerate concentration during continuous renal replacment therapy.

    Science.gov (United States)

    Sharma, Shilpa; Brugnara, Carlo; Betensky, Rebecca A; Waikar, Sushrut S

    2015-01-07

    Hypophosphatemia is a frequent complication during continuous renal replacement therapy (CRRT), a dialytic technique used to treat AKI in critically ill patients. This study sought to confirm that phosphate depletion during CRRT may decrease red blood cell (RBC) concentration of 2,3-diphosphoglycerate (2,3-DPG), a crucial allosteric effector of hemoglobin's (Hgb's) affinity for oxygen, thereby leading to impaired oxygen delivery to peripheral tissues. Phosphate mass balance studies were performed in 20 patients with severe AKI through collection of CRRT effluent. RBC concentrations of 2,3-DPG, venous blood gas pH, and oxygen partial pressure required for 50% hemoglobin saturation (P50) were measured at CRRT initiation and days 2, 4, and 7. Similar measurements were obtained on days 0 and 2 in a reference group of 10 postsurgical patients, most of whom did not have AKI. Associations of 2,3-DPG with laboratory parameters and clinical outcomes were examined using mixed-effects and Cox regression models. Mean 2,3-DPG levels decreased from a mean (±SD) of 13.4±3.4 µmol/g Hgb to 11.0±3.1 µmol/g Hgb after 2 days of CRRT (Plevels decreased from 29.7±4.4 mmHg to 26.7±4.0 mmHg (Plevels after 2 days of CRRT were not significantly lower than those in the reference group on day 2. Among patients receiving CRRT, 2,3-DPG decreased by 0.53 µmol/g Hgb per 1 g phosphate removed (95% confidence interval 0.38 to 0.68 µmol/g Hgb; P<0.001). Greater reductions in 2,3-DPG were associated with higher risk for death (hazard ratio, 1.43; 95% confidence interval, 1.09 to 1.88; P=0.01). CRRT-induced phosphate depletion is associated with measurable reductions in RBC 2,3-DPG concentration and a shift in the O2:Hgb affinity curve even in the absence of overt hypophosphatemia. 2,3-DPG reductions may be associated with higher risk for in-hospital death and represent a potentially avoidable complication of CRRT. Copyright © 2015 by the American Society of Nephrology.

  1. Statistical methods for estimating normal blood chemistry ranges and variance in rainbow trout (Salmo gairdneri), Shasta Strain

    Science.gov (United States)

    Wedemeyer, Gary A.; Nelson, Nancy C.

    1975-01-01

    Gaussian and nonparametric (percentile estimate and tolerance interval) statistical methods were used to estimate normal ranges for blood chemistry (bicarbonate, bilirubin, calcium, hematocrit, hemoglobin, magnesium, mean cell hemoglobin concentration, osmolality, inorganic phosphorus, and pH for juvenile rainbow (Salmo gairdneri, Shasta strain) trout held under defined environmental conditions. The percentile estimate and Gaussian methods gave similar normal ranges, whereas the tolerance interval method gave consistently wider ranges for all blood variables except hemoglobin. If the underlying frequency distribution is unknown, the percentile estimate procedure would be the method of choice.

  2. An enzymatic method for the rapid measurement of the hemoglobin A1c by a flow-injection system comprised of an electrochemical detector with a specific enzyme-reactor and a spectrophotometer

    International Nuclear Information System (INIS)

    Nanjo, Yoko; Hayashi, Ryuzo; Yao, Toshio

    2007-01-01

    A flow-injection analytical (FIA) system, comprised of an electrochemical detector with a fructosyl-peptide oxidase (FPOX-CET) reactor and a flow-type spectrophotometer, was proposed for the simultaneous measurement of glycohemoglobin and total hemoglobin in blood cell. The blood cell samples were hemolyzed with a surfactant and then treated with protease. In the first stage of operation, total hemoglobin in digested sample was determined spectrophotometrically. In the second stage, fructosyl valyl histidine (FVH) released from glycohemoglobin by the selective proteolysis was determined specifically using the electrochemical detector with the FPOX-CET reactor. The FIA system could be automatically processed at an analytical speed of 40 samples per hour. The proposed assay method could determine selectively only the glycated N-terminal residue of β-chain in glycohemoglobin and total hemoglobin in blood cell. The enzymatic hemoglobin A 1c (HbA 1c ) value calculated by the concentration ratio of the FVH to total hemoglobin, was closely correlated with the HbA 1c values certified by the Japan Diabetic Society (JDS) and the International Federation of Clinical Chemistry (IFCC)

  3. Analysis of hemoglobin adducts from acrylamide, glycidamide, and ethylene oxide in paired mother/cord blood samples from Denmark

    DEFF Research Database (Denmark)

    von Stedingk, Hans; Vikström, Anna C; Rydberg, Per

    2011-01-01

    The knowledge about fetal exposure to acrylamide/glycidamide from the maternal exposure through food is limited. Acrylamide, glycidamide, and ethylene oxide are electrophiles and form adducts with hemoglobin (Hb), which could be used for in vivo dose measurement. In this study, a method.......20-0.73) for glycidamide, and 0.43 (range 0.17-1.34) for ethylene oxide. In vitro studies with acrylamide and glycidamide showed a lower (0.38-0.48) rate of adduct formation with Hb in cord blood than with Hb in maternal blood, which is compatible with the structural differences in fetal and adult Hb. Together...... for analysis of Hb adducts by liquid chromatography-mass spectrometry, the adduct FIRE procedure, was applied to measurements of adducts from these compounds in maternal blood samples (n = 87) and umbilical cord blood samples (n = 219). The adduct levels from the three compounds, acrylamide, glycidamide...

  4. COMPARISON OF FRUCTOSAMINE AND GLYCOSYLATED HEMOGLOBIN IN A NON-INSULIN DEPENDENT DIABETIC POPULATION

    Directory of Open Access Journals (Sweden)

    M. Amini

    1999-08-01

    Full Text Available In an attempt to determine the clinical value of frnctosamine assay for monitoring type II diabetic patients, correlation of frnctosamine with glycosylated hemoglobin was studied. 100 patients with type II diabetes mcllitus were compared with 100 normal subjects. Fasting blood glucose, glycosylated hemoglobin, albumin and frnctosamine were measured in alt subjects. In the diabetic patients, a significant correlation was observed between fasting blood glucose and glycosylated hemoglobin (r = 0.64, p < 0.01 and scrum frnctosamine (r = 0.7, P < 0.01. Tlicrc was also a significant correlation between glycosylated hemoglobin and scrum frtictosmine (r = .94, I'<0.01. Frnctosamine, assay can be used as an index of diabetes control.

  5. Action of radiation on biosynthesis of hemoglobin and some of its electrophoretic fractions

    International Nuclear Information System (INIS)

    Starodub, N.F.; Kriklivyj, I.A.; Shur'yan, I.M.

    1976-01-01

    Biosynthesis of hemoglobin and some of its electrophoretic fractions in red cells of peripheral blood and spleen of irradiated (650 R) rats has been studied. Hemoglobin synthesis is found to be most drastically inhibited in the first and second fractions on the first and eighth days after irradiation and in the fifth and sixth fractions on the eighth day (less expressed). The synthesis is restored on the twelfth day, the process under study proceeding more slowly in the above-mentioned fractions than in others. In the course of radiation sickness, the biosynthesis of certain hemoglobin fractions varies differently in the hemoglobin-synthesizing cells of peripheral blood than in the cells of spleenic erythroid series

  6. HEMOGLOBIN A1C, BLOOD PRESSURE, AND LDL-CHOLESTEROL CONTROL AMONG HISPANIC/LATINO ADULTS WITH DIABETES: RESULTS FROM THE HISPANIC COMMUNITY HEALTH STUDY/STUDY OF LATINOS (HCHS/SOL).

    Science.gov (United States)

    Casagrande, Sarah Stark; Aviles-Santa, Larissa; Corsino, Leonor; Daviglus, Martha L; Gallo, Linda C; Espinoza Giacinto, Rebeca A; Llabre, Maria M; Reina, Samantha A; Savage, Peter J; Schneiderman, Neil; Talavera, Gregory A; Cowie, Catherine C

    2017-10-01

    To determine the prevalence of Hispanic/Latino adults with diabetes who meet target hemoglobin A1c, blood pressure (BP), and low-density-lipoprotein cholesterol (LDL-C) recommendations, and angiotensin-converting enzyme (ACE) inhibitors/angiotensin receptor blocker (ARB) and statin medication use by heritage and sociodemographic and diabetes-related characteristics. Data were cross-sectional, collected between 2008 and 2011, and included adults age 18 to 74 years who reported a physician diagnosis of diabetes in the Hispanic Community Health Study/Study of Latinos (N = 2,148). Chi-square tests compared the prevalence of hemoglobin A1c, BP, and LDL-C targets and ACE/ARB and statin use across participant characteristics. Predictive margins regression was used to determine the prevalence adjusted for sociodemographic characteristics. The overall prevalence of A1c Latinos with diabetes living in the U.S. With 8.4% meeting all three recommendations, substantial opportunity exists to improve diabetes control in this population. A1c = hemoglobin A1c; ABC = hemoglobin A1c, blood pressure, low-density-lipoprotein cholesterol; ACE = angiotensin-converting enzyme; ADA = American Diabetes Association; ARB = angiotensin receptor blocker; BMI = body mass index; BP = blood pressure; CHD = coronary heart disease; CVD = cardiovascular disease; HCHS/SOL = Hispanic Community Health Study/Study of Latinos; LDL-C = low-density-lipoprotein cholesterol; NHANES = National Health and Nutrition Examination Survey; PAD = peripheral artery disease.

  7. Two-photon excited fluorescence emission from hemoglobin

    Science.gov (United States)

    Sun, Qiqi; Zeng, Yan; Zhang, Wei; Zheng, Wei; Luo, Yi; Qu, Jianan Y.

    2015-03-01

    Hemoglobin, one of the most important proteins in blood, is responsible for oxygen transportation in almost all vertebrates. Recently, we discovered two-photon excited hemoglobin fluorescence and achieved label-free microvascular imaging based on the hemoglobin fluorescence. However, the mechanism of its fluorescence emission still remains unknown. In this work, we studied the two-photon excited fluorescence properties of the hemoglobin subunits, heme/hemin (iron (II)/(III) protoporphyrin IX) and globin. We first studied the properties of heme and the similar spectral and temporal characteristics of heme and hemoglobin fluorescence provide strong evidence that heme is the fluorophore in hemoglobin. Then we studied the fluorescence properties of hemin, globin and methemoglobin, and found that the hemin may have the main effect on the methemoglobin fluorescence and that globin has tryptophan fluorescence like other proteins. Finally, since heme is a centrosymmetric molecule, that the Soret band fluorescence of heme and hemoglobin was not observed in the single photon process in the previous study may be due to the parity selection rule. The discovery of heme two-photon excited fluorescence may open a new window for heme biology research, since heme as a cofactor of hemoprotein has many functions, including chemical catalysis, electron transfer and diatomic gases transportation.

  8. High impact of uranyl ions on carrying-releasing oxygen capability of hemoglobin-based blood substitutes

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Li; Du, Lili; Liu, Wenyuan; Liu, Zhichao [Northwest Institute of Nuclear Technology, Xi' an, Shaanxi (China); Jia, Yi; Li, Junbai [Beijing National Laboratory for Molecular Sciences, CAS Key Laboratory of Colloid Interface and Chemical Thermodynamics, Institute of Chemistry, Chinese Academy of Sciences, Beijing (China)

    2015-01-07

    The effect of radioactive UO{sub 2}{sup 2+} on the oxygen-transporting capability of hemoglobin-based oxygen carriers has been investigated in vitro. The hemoglobin (Hb) microspheres fabricated by the porous template covalent layer-by-layer (LbL) assembly were utilized as artificial oxygen carriers and blood substitutes. Magnetic nanoparticles of iron oxide (Fe{sub 3}O{sub 4}) were loaded in porous CaCO{sub 3} particles for magnetically assisted chemical separation (MACS). Through the adsorption spectrum of magnetic Hb microspheres after adsorbing UO{sub 2}{sup 2+}, it was found that UO{sub 2}{sup 2+} was highly loaded in the magnetic Hb microspheres, and it shows that the presence of UO{sub 2}{sup 2+} in vivo destroys the structure and oxygen-transporting capability of Hb microspheres. In view of the high adsorption capacity of UO{sub 2}{sup 2+}, the as-assembled magnetic Hb microspheres can be considered as a novel, highly effective adsorbent for removing metal toxins from radiation-contaminated bodies, or from nuclear-power reactor effluent before discharge into the environment. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. Determinants of Anemia and Hemoglobin Concentration in Haitian School-Aged Children

    Science.gov (United States)

    Iannotti, Lora L.; Delnatus, Jacques R.; Odom, Audrey R.; Eaton, Jacob C.; Griggs, Jennifer J.; Brown, Sarah; Wolff, Patricia B.

    2015-01-01

    Anemia diminishes oxygen transport in the body, resulting in potentially irreversible growth and developmental consequences for children. Limited evidence for determinants of anemia exists for school-aged children. We conducted a cluster randomized controlled trial in Haiti from 2012 to 2013 to test the efficacy of a fortified school snack. Children (N = 1,047) aged 3–13 years were followed longitudinally at three time points for hemoglobin (Hb) concentrations, anthropometry, and bioelectrical impedance measures. Dietary intakes, infectious disease morbidities, and socioeconomic and demographic factors were collected at baseline and endline. Longitudinal regression modeling with generalized least squares and logit models with random effects identified anemia risk factors beyond the intervention effect. At baseline, 70.6% of children were anemic and 2.6% were severely anemic. Stunting increased the odds of developing anemia (adjusted odds ratio [OR]: 1.48, 95% confidence interval [CI]: 1.05–2.08) and severe anemia (adjusted OR: 2.47, 95% CI: 1.30–4.71). Parent-reported vitamin A supplementation and deworming were positively associated with Hb concentrations, whereas fever and poultry ownership showed a negative relationship with Hb concentration and increased odds of severe anemia, respectively. Further research should explore the full spectrum of anemia etiologies in school children, including genetic causes. PMID:26350448

  10. Cloned Hemoglobin Genes Enhance Growth Of Cells

    Science.gov (United States)

    Khosla, Chaitan; Bailey, James E.

    1991-01-01

    Experiments show that portable deoxyribonucleic acid (DNA) sequences incorporated into host cells make them produce hemoglobins - oxygen-binding proteins essential to function of red blood cells. Method useful in several biotechnological applications. One, enhancement of growth of cells at higher densities. Another, production of hemoglobin to enhance supplies of oxygen in cells, for use in chemical reactions requiring oxygen, as additive to serum to increase transport of oxygen, and for binding and separating oxygen from mixtures of gases.

  11. Hematocrit, Anemia, and Arm Preference for Blood Sample ...

    African Journals Online (AJOL)

    lower cut-off of 33% or hemoglobin (Hb) concentration of. 11 gram% was ... venous blood of 200 antenatal women at the University of Nigeria Teaching Hospital (UNTH). Enugu ..... and emphasis was placed on the importance of good nutrition.

  12. Hemoglobin redox reactions and red blood cell aging.

    Science.gov (United States)

    Rifkind, Joseph M; Nagababu, Enika

    2013-06-10

    The physiological mechanism(s) for recognition and removal of red blood cells (RBCs) from circulation after 120 days of its lifespan is not fully understood. Many of the processes thought to be associated with the removal of RBCs involve oxidative stress. We have focused on hemoglobin (Hb) redox reactions, which is the major source of RBC oxidative stress. The importance of Hb redox reactions have been shown to originate in large parts from the continuous slow autoxidation of Hb producing superoxide and its dramatic increase under hypoxic conditions. In addition, oxidative stress has been shown to be associated with redox reactions that originate from Hb reactions with nitrite and nitric oxide (NO) and the resultant formation of highly toxic peroxynitrite when NO reacts with superoxide released during Hb autoxidation. The interaction of Hb, particularly under hypoxic conditions with band 3 of the RBC membrane is critical for the generating the RBC membrane changes that trigger the removal of cells from circulation. These changes include exposure of antigenic sites, increased calcium leakage into the RBC, and the resultant leakage of potassium out of the RBC causing cell shrinkage and impaired deformability. The need to understand the oxidative damage to specific membrane proteins that result from redox reactions occurring when Hb is bound to the membrane. Proteomic studies that can pinpoint the specific proteins damaged under different conditions will help elucidate the cellular aging processes that result in cells being removed from circulation.

  13. Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study.

    Science.gov (United States)

    Wittenmeier, Eva; Bellosevich, Sophia; Mauff, Susanne; Schmidtmann, Irene; Eli, Michael; Pestel, Gunther; Noppens, Ruediger R

    2015-10-01

    Collecting a blood sample is usually necessary to measure hemoglobin levels in children. Especially in small children, noninvasively measuring the hemoglobin level could be extraordinarily helpful, but its precision and accuracy in the clinical environment remain unclear. In this study, noninvasive hemoglobin measurement and blood gas analysis were compared to hemoglobin measurement in a clinical laboratory. In 60 healthy preoperative children (0.2-7.6 years old), hemoglobin was measured using a noninvasive method (SpHb; Radical-7 Pulse Co-Oximeter), a blood gas analyzer (clinical standard, BGAHb; ABL 800 Flex), and a laboratory hematology analyzer (reference method, labHb; Siemens Advia). Agreement between the results was assessed by Bland-Altman analysis and by determining the percentage of outliers. Sixty SpHb measurements, 60 labHb measurements, and 59 BGAHb measurements were evaluated. In 38% of the children, the location of the SpHb sensor had to be changed more than twice for the signal quality to be sufficient. The bias/limits of agreement between SpHb and labHb were -0.65/-3.4 to 2.1 g·dl(-1) . Forty-four percent of the SpHb values differed from the reference value by more than 1 g·dl(-1) . Age, difficulty of measurement, and the perfusion index (PI) had no influence on the accuracy of SpHb. The bias/limits of agreement between BGAHb and labHb were 1.14/-1.6 to 3.9 g·dl(-1) . Furthermore, 66% of the BGAHb values differed from the reference values by more than 1 g·dl(-1) . The absolute mean difference between SpHb and labHb (1.1 g·dl(-1) ) was smaller than the absolute mean difference between BGAHb and labHb (1.5 g·dl(-1) /P = 0.024). Noninvasive measurement of hemoglobin agrees more with the reference method than the measurement of hemoglobin using a blood gas analyzer. However, both methods can show clinically relevant differences from the reference method (ClinicalTrials.gov: NCT01693016). © 2015 John Wiley & Sons Ltd.

  14. Ultrasonic processing for recovery of chicken erythrocyte hemoglobin

    Science.gov (United States)

    Hemoglobin from chicken blood has been shown to be a good substitute for synthetic polymeric flocculants. One stage of processing the blood entails breaking open the cells and releasing the cytoplasmic contents; in the present study, we investigate the use of ultrasonic processing at this stage. Was...

  15. Red blood cells sensitivity to oxidative stress in the presence of low concentrations of uranium compound

    Energy Technology Data Exchange (ETDEWEB)

    Shevchenko, O.G. [Institute of Biology, Komi Scientific Centre, Ural Branch of Russian Academy of Sciences, 167982, Syktyvkar (Russian Federation)

    2014-07-01

    Uranium is a natural radioactive element widespread in biosphere. There are a few works that examined cellular and molecular mechanisms of uranium toxicity. Red blood cells are classical model to investigate toxicity mechanisms on cell membrane system. The aim of present work is to study the effect of uranyl ion in nano-molar concentrations on erythrocytes sensitivity (in vitro) to factors provoking acute oxidative stress. Uranyl ions were added to suspension of mice red blood cells in PBS as UO{sub 2}Cl{sub 2} solution. Samples were incubated in a thermostatic shaker at 37 deg. C during 3-5 hours. Than acute oxidative stress was induced by H{sub 2}O{sub 2} (0.9 mM) or AAPH (5 mM) solutions. Destabilization of the membrane was induced by nonionic detergent Triton X-100. The hemolysis degree and the content of LPO secondary products reacting with 2-thiobarbituric acid in the incubation mixture were determined spectrophotometrically. The ratio of hemoglobin various forms (oxyHb, metHb and ferrylHb) was calculated taking into account extinction coefficients. It was shown that uranyl chloride enhances cell sensitivity to nonionic detergent Triton X-100 effects, indicating alterations of membrane acyl chain order due to contact with the radionuclide ions. Uranium exposure also caused an increase in the cell sensitivity to the AAPH effects, resulted in a decrease in red cell survival rate, a sharp increase in accumulation of hemoglobin oxidation products and a slight increase in the concentration of LPO secondary products. Thus, uranyl ions change physicochemical properties of the erythrocyte membranes that resulted in increased sensitivity to effects of peroxyl radicals formed by thermal decomposition of AAPH. On the contrary, use of another source of free radicals - H{sub 2}O{sub 2} - after uranyl ions exposure resulted in marked decrease of oxidative hemolysis, inhibition of LPO and hemoglobin oxidation. Since the uranium chemical properties similar to properties of

  16. Biophysical basis of hypoxic radioprotection by deoxygenated dextran-hemoglobin

    International Nuclear Information System (INIS)

    Wong, J.T.; Hill, R.P.

    1986-01-01

    Perfusion with deoxygenated dextran-hemoglobin provides an effective method for inducing hypoxic radioprotection of normal tissues during radiation treatment of tumors. In this study, the dependence of P50, the half-saturation pressure of oxygen binding to dextran-hemoglobin, was analyzed as a function of solution temperature and pH. The variation of attainable radioprotection with P50, and with the amount of collateral blood entering into the perfused region, was calculated. Upon perfusion of canine gracilis muscle with deoxygenated dextran-hemoglobin, a rapid onset of extensive venous hypoxia was observed

  17. Modifiers of hemoglobin/oxygen affinity as sensitizers of tumors to radiation

    International Nuclear Information System (INIS)

    Hirst, D.G.; Wood, P.J.

    1987-01-01

    A powerful mechanism in the control of oxygen delivery to tissues is the allosteric modification of hemoglobin. Increased or decreased release of oxygen can be achieved by altering the affinity of hemoglobin for oxygen. Several studies have shown that tumor radiosensitivity is dependent on this relationship. The authors studied affinity changes produced in two distinctly different ways. Tumor bearing mice were given isovolemic exchange blood transfusions with the blood from donor mice which had been exposed to abnormal oxygen tensions, leading to increased or slightly decreased levels of 2,3-diphosphoglycerate (2,3 DPG) in their blood. When the recipient mice were irradiated, those receiving the blood with higher 2,3 DPG levels showed greater tumor sensitivity to radiation. An alternative strategy is the use of drugs which directly alter hemoglobin/oxygen affinity. The authors studied three antihyperlipoproteinemia drugs, all of which have produced markedly reduced affinities in vivo. Preliminary data indicate that the radiosensitization produced by at least one of these compounds is less than would have been expected from the 2,3 DPG experiments

  18. Correlation between Oxygen Saturation and Hemoglobin and Hematokrit Levels in Tetralogy of Fallot Patients

    Directory of Open Access Journals (Sweden)

    Farhatul Inayah Adiputri

    2016-03-01

    Full Text Available Background: Hemoglobin and hematocrit levels increase in Tetralogy of Fallot (TOF but the oxygen saturation declines. Reduced hemoglobin in circulating blood as a parameter of cyanosis does not indicate rising hemoglobin due to the ‘not-working’ hemoglobins that affect the oxygen saturation. Increasing hematocrit is the result of secondary erythrocytosis caused by declining oxygen level in blood, which is related to the oxygen saturation. This study was conducted to find the correlation between oxygen saturation and hemoglobin and hematocrite levels in TOF patients. Methods: This study was undertaken at Dr. Hasan Sadikin General Hospital in the period of January 2011 to December 2012 using the cross-sectional analytic method with total sampling technique. Inclusion criteria were medical records of TOF patients diagnosed based on echocardiography that included data on oxygen saturation, hemoglobin, and hematocrite. Exclusion criteria was the history of red blood transfusion. Results: Thirty medical records of TOF patiens from Dr. Hasan Sadikin General Hospital Bandung were included in this study. Due to skewed data distribution, Spearman correlation test was used to analyze the data. There was a significant negative correlation between oxygen saturation and hematocrit level (r= -0.412; p=0.024 and insignificant correlation between oxygen saturation and hemoglobin (r=-0.329; p= 0.076. Conclusions: There is a weak negative correlation between oxygen saturation and hematocrite levels

  19. Led Astray by Hemoglobin A1c

    Directory of Open Access Journals (Sweden)

    Jean Chen MD

    2016-01-01

    Full Text Available Hemoglobin A1c (A1c is used frequently to diagnose and treat diabetes mellitus. Therefore, it is important be aware of factors that may interfere with the accuracy of A1c measurements. This is a case of a rare hemoglobin variant that falsely elevated a nondiabetic patient’s A1c level and led to a misdiagnosis of diabetes. A 67-year-old male presented to endocrine clinic for further management after he was diagnosed with diabetes based on an elevated A1c of 10.7%, which is approximately equivalent to an average blood glucose of 260 mg/dL. Multiple repeat A1c levels remained >10%, but his home fasting and random glucose monitoring ranged from 92 to 130 mg/dL. Hemoglobin electrophoresis and subsequent genetic analysis diagnosed the patient with hemoglobin Wayne, a rare hemoglobin variant. This variant falsely elevates A1c levels when A1c is measured using cation-exchange high-performance liquid chromatography. When the boronate affinity method was applied instead, the patient’s A1c level was actually 4.7%. Though hemoglobin Wayne is clinically silent, this patient was erroneously diagnosed with diabetes and started on an antiglycemic medication. Due to this misdiagnosis, the patient was at risk of escalation in his “diabetes management” and hypoglycemia. Therefore, it is important that providers are aware of factors that may result in hemoglobin A1c inaccuracy including hemoglobin variants.

  20. Hemoglobin alpha 2 gene +861 G>A polymorphism in Turkish ...

    African Journals Online (AJOL)

    Thalassemia is an inherited blood disorder which is divided into two groups: alpha and beta. HBA1 and HBA2 are the two genes associated with alpha thalassemia. The aim of this study is to investigate abnormal hemoglobin variants of alpha globin gene in healthy abnormal hemoglobin carrying individuals with intact beta ...

  1. Changes in blood values in elite cyclist

    DEFF Research Database (Denmark)

    Mørkeberg, J S; Belhage, B; Damsgaard, R

    2009-01-01

    samples were obtained from 28 elite, male cyclists. Blood was analyzed for hematocrit (Hct), hemoglobin concentration ([Hb]) and % reticulocytes. Seventy-six percent of all samples were collected out-of-competition (OOC). From December 2006 to September 2007, the average Hct and [Hb] decreased by 4...

  2. Prevalence of Anemia and Hemoglobin Disorders Among School Children in Myanmar.

    Science.gov (United States)

    Wah, Saw Thu; Yi, Yoon Shwe; Khin, Aye Aye; Plabplueng, Chotiros; Nuchnoi, Pornlada

    2017-01-01

    The prevalence of anemia is high in the population of Myanmar and hypochromic microcytic anemia (HMA) is predominant. The objective of our study was to determine the prevalence of anemia and causes of HMA among school children. A cross-sectional study was conducted on 239 children from Thanlyin and Insein Townships, Yangon Region, Myanmar. Complete blood count (CBC) and blood film morphology was examined on venous blood samples. Hypochromic microcytic anemia cases were subsequently analyzed for serum ferritin and cellulose acetate hemoglobin (Hb) electrophoresis. The prevalence of anemia was 46.4%; 27.6% had mild, while 18.8% had moderate anemia, and no case of severe anemia was detected. The mean Hb concentration was 11.7 ± 0.9 g/dL. The younger age group (8-11 years) had a significantly higher prevalence of anemia than the older age group (12-15 years) (p = 0.029). Blood film morphology revealed a 50.6% red blood cell (RBC) disorder; HMA was the most common type (70.2%). Out of 85 children with HMA, three children (3.5%) had iron deficiency and all had comorbidity with Hb AE (β A /β E ) (Hb E trait). Hemoglobin electrophoresis illustrated that Hb AA (β A /β A ) (31, 36.5%) and Hb AE (β A /β E ) trait (31, 36.5%) were the most common types followed by β-thalassemia (β-thal) trait (19, 22.3%) and Hb EE (β E /β E ) (homozygous Hb E; HBB: c.79G>A) (three, 3.5%). Hematocrit [or packed cell volume (PCV)], mean corpuscular volume (MCV), mean corpuscular Hb (MCH) and mean corpuscular Hb concentration (MCHC), showed a significant difference between Hb AE, Hb EE and β-thal trait (p = 0.029, 0.023, 0.015 and 0.01, respectively). Our findings will provide valuable information for the management of anemia in the Myanmar school-age population.

  3. Identification of a haptoglobin-hemoglobin complex in the Alaskan Least Cisco (Coregonus sardinella).

    Science.gov (United States)

    Wahl, S M; Boger, J K; Michael, V; Duffy, L K

    1992-01-01

    The hemoglobin and a hemoglobin binding protein have been characterized in the Arctic fish (Coregonus sardinella). The evolutionary significance of the hemoglobin and plasma protein differences between fish and mammals is still unresolved. Blood samples from the Alaskan Least Cisco were separated into plasma and hemoglobin fractions and the proteins in these fractions were analyzed both by alkaline agarose gel electrophoresis, by isolelectric focusing, and by capillary electrophoresis. Staining the plasma proteins gels with o-dianisidine revealed hemoglobin containing protein complexes. A hemoglobin-containing band was observed in hemolyzed plasma which did not migrate with free hemoglobin, and is believed to be hemoglobin-haptoglobin complex. Size exclusion chromatography further characterized the hemoglobin as disassociating freely into dimers, and hemoglobin-haptoglobin complex having a molecular weight greater then 200,000 daltons.

  4. High affinity hemoglobin and Parkinson's disease.

    Science.gov (United States)

    Graham, Jeffrey; Hobson, Douglas; Ponnampalam, Arjuna

    2014-12-01

    Parkinson's disease (PD) is a neurodegenerative disorder characterized by the loss of dopaminergic neurons in the substantia nigra (SN) region of the midbrain. Oxidative damage in this region has been shown to play an important role in the pathogenesis of this disease. Human neurons have been discovered to contain hemoglobin, with an increased concentration seen in the neurons of the SN. High affinity hemoglobin is a clinical entity resulting from mutations that create a functional increase in the binding of hemoglobin to oxygen and an inability to efficiently unload it to tissues. This can result in a number of metabolic compensatory changes, including an elevation in circulating hemoglobin and an increase in the molecule 2,3-diphosphoglycerate (2,3-DPG). Population based studies have revealed that patients with PD have elevated hemoglobin as well as 2,3-DPG levels. Based on these observations, we hypothesize that the oxidative damage seen in PD is related to an underlying high affinity hemoglobin subtype. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Hemoglobin affinity in Andean rodents

    Directory of Open Access Journals (Sweden)

    HRVOJ OSTOJIC

    2002-01-01

    Full Text Available Blood hemoglobin oxygen affinity (P50 was measured in three Andean species and in the laboratory rat (control, all raised near sea level. Chinchilla lanigera (Molina, 1792 has an altitudinal habitat range from low Andean slopes up to 3000 m., while Chinchilla brevicaudata (Waterhouse, 1848 has an altitudinal range from 3000 to 5000 m. The laboratory type guinea pig, wild type guinea pig (Cavia porcellus, (Waterhouse, 1748, and laboratory rat (Rattus norvegicus were also raised at sea level. The Andean species had high hemoglobin oxygen affinities (low P50 compared with the rat. Chinchilla brevicaudata had a higher affinity than Chinchilla lanigera. The wild type guinea pig had a higher affinity than the laboratory type. As has been shown in other species, this is another example of an inverse correlation between the altitude level and the P50 values. This is the first hemoglobin oxygen affinity study in Chinchilla brevicaudata.

  6. Relationship between changes in hemoglobin glycosilated and improvement of body composition in patients with morbid obesity after tubular laparoscopic gastrectomy.

    Science.gov (United States)

    Gallart-Aragón, Tania; Fernández-Lao, Carolina; Cózar-Ibañez, Antonio; Cantarero-Villanueva, Irene; Cambil-Martín, Jacobo; Jiménez Ríos, José Antonio; Arroyo-Morales, Manuel

    2017-12-29

    The objective of our study is to analyze the possible relationship between changes in glycemic profile and body composition parameters in morbid obesity patients after tubular laparoscopic gastrectomy. A prospective observational cohort study with 69 patients was performed. The variables analyzed were body weight, blood glucose, hemoglobin, glycosylated, high density lipoprotein, low density lipoprotein, triglycerides, and waist and hip circumference. An analysis of variance of repeated measurements (ANOVA) and a correlation analysis through the Pearson test were carried out. A significant reduction in weight (p<.001 after surgery) and in glycosylated hemoglobin (p<.036) and waist hip (p<.001) were found at 6 months after surgery. There was no significant difference in the rest of the variables studied. In correlation analysis, a significant positive correlation was found between the change in concentration of hemoglobin glycosylated and hip circumference (p=.047; r=0.237), the smaller the hip circumference, the lower the concentration of glycosylated hemoglobin. Tubular laparoscopic gastrectomy is an effective technique for the treatment of morbidly obese patients with type 2 diabetes mellitus. The reduction in the perimeter of hip is related to glycosylated hemoglobin reduction 6 months after intervention. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  7. Prefrontal cerebral blood volume patterns while playing video games--a near-infrared spectroscopy study.

    Science.gov (United States)

    Nagamitsu, Shinichiro; Nagano, Miki; Yamashita, Yushiro; Takashima, Sachio; Matsuishi, Toyojiro

    2006-06-01

    Video game playing is an attractive form of entertainment among school-age children. Although this activity reportedly has many adverse effects on child development, these effects remain controversial. To investigate the effect of video game playing on regional cerebral blood volume, we measured cerebral hemoglobin concentrations using near-infrared spectroscopy in 12 normal volunteers consisting of six children and six adults. A Hitachi Optical Topography system was used to measure hemoglobin changes. For all subjects, the video game Donkey Kong was played on a Game Boy device. After spectroscopic probes were positioned on the scalp near the target brain regions, the participants were asked to play the game for nine periods of 15s each, with 15-s rest intervals between these task periods. Significant increases in bilateral prefrontal total-hemoglobin concentrations were observed in four of the adults during video game playing. On the other hand, significant decreases in bilateral prefrontal total-hemoglobin concentrations were seen in two of the children. A significant positive correlation between mean oxy-hemoglobin changes in the prefrontal region and those in the bilateral motor cortex area was seen in adults. Playing video games gave rise to dynamic changes in cerebral blood volume in both age groups, while the difference in the prefrontal oxygenation patterns suggested an age-dependent utilization of different neural circuits during video game tasks.

  8. Effects of diaspirin cross-linked hemoglobin (DCLHb) during and post-CPR in swine.

    Science.gov (United States)

    Chow, M S; Fan, C; Tran, H; Zhao, H; Zhou, L

    2001-04-01

    The purpose of the study was to test the hypothesis that diaspirin cross-linked hemoglobin (DCLHb) can produce improved resuscitation during cardiac arrest. DCLHb, a derivative of human hemoglobin, has previously been demonstrated to produce a vasopressor response that is associated with increased blood flow to vital organs. In addition, it is an oxygen carrier. These effects may be beneficial to extreme low flow states, such as that during cardiac arrest and cardiopulmonary resuscitation (CPR). Experimental cardiac arrest and CPR were carried out in 32 anesthetized immature pigs. In each animal, ventricular fibrillation was induced for 5 min, followed by 10 min of standard CPR with a pneumatic device and room air ventilation. High (15 ml/kg) and low (5 ml/kg) doses of DCLHb or equivalent volume of normal saline were infused at the beginning of CPR in a random and blind manner. Cardiac output, organ blood flow, aortic pressure, coronary perfusion pressure, blood gases, and lactate concentrations were obtained before and during CPR. Following the 10-min CPR, the animals were defibrillated and the return of spontaneous circulation (ROSC) determined. DCLHb treatment achieved 75% ROSC compared with 25% in the saline group (p CPR significantly improves ROSC. This is most likely related to its improvement in coronary perfusion and myocardial oxygen delivery.

  9. Myth or reality : Hematocrit and hemoglobin differ in trauma

    NARCIS (Netherlands)

    Nijboer, Johanna M. M.; van der Horst, Iwan C. C.; Hendriks, Herman G. D.; ten Duis, Hendrik-Jan; Nijsten, Maarten W. N.

    Background: Estimating blood loss in trauma patients usually involves the determination of hematocrit (Ht) or hemoglobin (Hb). However, in trauma patients, a poorly substantiated habit exists to determine both Ht and Hb in assessing acute blood loss. This suggests that Ht and Hb provide different

  10. PLASMA PROTEIN AND HEMOGLOBIN PRODUCTION

    Science.gov (United States)

    Robscheit-Robbins, F. S.; Miller, L. L.; Whipple, G. H.

    1947-01-01

    Given healthy dogs fed abundant iron and protein-free or low protein diets with sustained anemia and hypoproteinemia, we can study the capacity of these animals to produce simultaneously new hemoglobin and plasma protein. Reserve stores of blood protein-building materials are measurably depleted and levels of 6 to 8 gm. per cent for hemoglobin and 4 to 5 gm. per cent for plasma protein can be maintained for weeks or months depending upon the intake of food proteins or amino acid mixtures. These dogs are very susceptible to infection and various poisons. Dogs tire of these diets and loss of appetite terminates many experiments. Under these conditions (double depletion) standard growth mixtures of essential amino acids are tested to show the response in blood protein output and urinary nitrogen balance. As a part of each tabulated experiment one of the essential amino acids is deleted from the complete growth mixture to compare such response with that of the whole mixture. Methionine, threonine, phenylalanine, and tryptophane when singly eliminated from the complete amino acid mixture do effect a sharp rise in urinary nitrogen. This loss of urinary nitrogen is corrected when the individual amino acid is replaced in the mixture. Histidine, lysine, and valine have a moderate influence upon urinary nitrogen balance toward nitrogen conservation. Leucine, isoleucine, and arginine have minimal or no effect upon urinary nitrogen balance when these individual amino acids are deleted from the complete growth mixture of amino acids during 3 to 4 week periods. Tryptophane and to a less extent phenylalanine and threonine when returned to the amino acid mixture are associated with a conspicuous preponderance of plasma protein output over the hemoglobin output (Table 4). Arginine, lysine, and histidine when returned to the amino acid mixture are associated with a large preponderance of hemoglobin output. Various amino acid mixtures under these conditions may give a positive

  11. Comparison of Hemoglobin A1c assay performance on two different commercial systems

    Directory of Open Access Journals (Sweden)

    Jozo Ćorić

    2015-04-01

    Full Text Available Introduction: Glycated hemoglobin (HbA1c is formed by non-enzymatic binding of glucose to the free amino group of the N-terminal end of the ß-chain of hemoglobin A. HbA1c is representative of the mean blood glucose level over three months. The aim of the study was to evaluate the Hemoglobin A1c immunoturbidimetric assay performance on two different commercial systems.Methods: We evaluated the precision and trueness for determination of HbA1c in whole blood. Concentrations of total hemoglobin and HbA1c were evaluated on Dimension Xpand (Siemens and Cobas 501 (Roche analyzers. HbA1c was measured in a latex agglutination inhibition test. Commercial controls Liquichek Diabetes Control Level 1 and Liquichek Diabetes Control Level 2 (Bio Rad at two levels were used for quality control. Analytical validation of HbA1c included: within-run imprecision, between-day imprecision, inaccuracy and comparison determination on the human samples on 2 systems: Dimension Xpand and Cobas 501 analyzers. Results: Within-run imprecision on the commercially controls for Level 1 is 4.5% and Level 2 is 3.2% between-day imprecision on commercially controls is 6.1% Level 1 and 5.1% Level 2 for respectively inac- curacy on commercially controls for Level 1 is 1.8% and Level 2 is 4.8%. Method comparison on human samples shows the correlation coefficient of 0.99.Conclusion: The presented results of the analytical evaluation methods for the determination of HbA1c showed an acceptable accuracy and precision.

  12. [Influence of mastication on the amount of hemoglobin in human brain tissue].

    Science.gov (United States)

    Sasaki, A

    2001-03-01

    The purpose of this study was to investigate the influence of mastication on the amount of hemoglobin in human brain tissue. Nine healthy volunteers (6 males and 3 females) participated in this study. They underwent two tasks: 1) at rest, 2) gum-chewing. In seven of the nine (4 males and 3 females), experimental occlusal interference was applied to the first molar of the mandibule on the habitual masticatory side. They underwent the gum-chewing task. To evaluate the amount of hemoglobin, both the hemoglobin oxygenation state and blood volume during gum-chewing were measured in the frontal region, using near-infrared spectroscopy. The amount of total-hemoglobin (blood volume) and oxyhemoglobin of subjects significantly increased during gum-chewing (p experimental occlusal interference was imposed on the subject, the amount of them significantly decreased compared with subjects without experimental occlusal interference (p < 0.05). The results suggested that increases of cerebral blood flow in the frontal region were not due to the mandibular movement, and that human brain activity caused by mastication was not only in the cortical masticatory area but also in the frontal region.

  13. Correlations of Hemoglobin Level and Perioperative Blood Transfusion with the Prognosis of Gastric Cancer: A Retrospective Study.

    Science.gov (United States)

    Wu, Gang; Zhang, Dai-Yang; Duan, Yu-Han; Zhang, Ying-Qiong; Cui, Xian-Nian; Luo, Zheng

    2017-05-23

    BACKGROUND This study was designed to explore the correlations of hemoglobin level (Hb) and perioperative blood transfusion with the prognosis of gastric cancer (GC). MATERIAL AND METHODS Our study consisted of 210 patients with GC who all received a D2 radical operation. These patients were assigned into three groups: 68 cases in group A (blood transfusion >5 U); 59 cases in group B (blood transfusion blood transfusion). A 5-year follow-up was conducted to evaluate the disease-free survival of the patients. Univariate analysis was performed to reveal the relationship between the indicators and the patients with GC. Kaplan-Meier method was employed to analyze the survival rate of patients, and Cox regression analysis was applied to determine the independent prognostic factors of GC. RESULTS The univariate analysis indicated that age, perioperative blood transfusion amount, TNM staging, maximal tumor diameter, differentiation degree and invasion degree were associated with the prognosis of GC. The Kaplan-Meier curve showed that the disease-free survival rate was declined in the patients who were older, those received more amount of blood transfusion, those in advanced TNM staging, those had larger tumor diameter, and those with decreased degree of differentiation and invasion. Cox regression analysis indicated that perioperative blood transfusion, maximal tumor diameter and invasion degree were the independent factors affecting disease-free survival of the GC. CONCLUSIONS Our study revealed that large amount of perioperative blood transfusion leads to poor prognosis of GC.

  14. Diffusion coefficients of oxygen and hemoglobin as obtained simultaneously from photometric determination of the oxygenation of layers of hemoglobin solutions

    NARCIS (Netherlands)

    Spaan, J. A.; Kreuzer, F.; van Wely, F. K.

    1980-01-01

    The oxygenation of layers of deoxygenated hemoglobin solutions after a sudden exposure to a gas containing oxygen at a partial pressure P1 has been studied by a photometric method. Layer thicknesses varied between 50 and 250 micron, hemoglobin concentrations between 0.1 and 0.34kg/l, and oxygen

  15. Association between blood glucose level derived using the oral glucose tolerance test and glycated hemoglobin level.

    Science.gov (United States)

    Kim, Hyoung Joo; Kim, Young Geon; Park, Jin Soo; Ahn, Young Hwan; Ha, Kyoung Hwa; Kim, Dae Jung

    2016-05-01

    Glycated hemoglobin (HbA1c) is widely used as a marker of glycemic control. Translation of the HbA1c level to an average blood glucose level is useful because the latter figure is easily understood by patients. We studied the association between blood glucose levels revealed by the oral glucose tolerance test (OGTT) and HbA1c levels in a Korean population. A total of 1,000 subjects aged 30 to 64 years from the Cardiovascular and Metabolic Diseases Etiology Research Center cohort were included. Fasting glucose levels, post-load glucose levels at 30, 60, and 120 minutes into the OGTT, and HbA1c levels were measured. Linear regression of HbA1c with mean blood glucose levels derived using the OGTT revealed a significant correlation between these measures (predicted mean glucose [mg/dL] = 49.4 × HbA1c [%] - 149.6; R (2) = 0.54, p Glucose (ADAG) study and Diabetes Control and Complications Trial (DCCT) cohort. Discrepancies between our results and those of the ADAG study and DCCT cohort may be attributable to differences in the test methods used and the extent of insulin secretion. More studies are needed to evaluate the association between HbA1c and self monitoring blood glucose levels.

  16. A Microplate Assay for the Determination of Hemoglobin Concentration

    National Research Council Canada - National Science Library

    Frenchik, Michael D; McFaul, Steve J; Tsonev, Latchezar I

    2004-01-01

    ... (NaOH), and converts all hemoglobin species, including COHb, to AHD within 5 min. Both protocols are carried out in cuvettes, and are, therefore, time intensive and difficult to manage when many samples are quantified. This impedes acquisition of triplicate values for each sample necessary to improve accuracy and determine statistical significance.

  17. Determining total hemoglobin mass by means of {sup 13}CO breath analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sowa, Marcus; Hering, Peter [Institut fuer Lasermedizin, Universitaetsklinikum Duesseldorf (Germany)

    2010-07-01

    The aim of our investigations is the development of a non-invasive method for the determination of the total hemoglobin mass in the human body by means of Cavity Leak-Out Spectroscopy (CALOS). The mentioned CALOS system utilizes a CO gas laser in the mid infrared region around 5{mu}m. This system allows isotopologue selective online measurements of {sup 13}CO with a sensitivity of 7 ppb.Hz{sup -1/2}. {sup 13}CO is a non radioactive isotopologue occurring in a ratio of about 1.1 % of the natural CO composition. CO is commonly known as a highly toxic gas but it is also endogenously produced during heme degradation. About 80 % of this CO is exhaled yielding to CO concentrations between 1 ppm to 4 ppm in healthy humans. Transportation of CO through the body is established by hemoglobin which has a high affinity towards CO. Because of this fact inhaled CO is taken up by the blood until equilibrium between the alveolar air and the blood is reached. By determining the exhaled CO concentrations before and after the inhalation of a certain amount of CO a measure for the t-Hb mass can be calculated. The enormous advantage of the isotopologue measurement is the very small amount of {sup 13}CO which can be used for harmless CO inhalation. All data necessary for calculating the t-Hb mass are obtained from breath measurements making this method non invasive.

  18. [Current status of vitamin A deficiency in preschool children in Dongguan, China and the effect of vitamin A on serum ferritin and red blood cell parameters].

    Science.gov (United States)

    Zhang, Zhen-Hong; Ni, Ming; Hu, Yuan

    2018-03-01

    To investigate the current status of vitamin A deficiency in preschool children in Dongguan, China, as well as the effect of vitamin A on serum ferritin, red blood cell, and reticulocyte parameters. Cluster sampling was performed from April 2015 to December 2016 to select 2 085 preschool children (3-6 years old) without any disease in Dongguan. Routine blood test, reticulocyte count, serum ferritin measurement, hemoglobin electrophoresis, and vitamin A measurement were performed for all children. The associations of age and sex with vitamin A and serum ferritin concentrations were analyzed. The effect of vitamin A concentration on serum ferritin, red blood cell, and reticulocyte parameters and the effect of reduced iron storage caused by vitamin A deficiency on red blood cell parameters were evaluated. Of the 2 085 children, 140 (6.71%) had reduced iron storage, and 678 (32.52%) had vitamin A deficiency. Among the 678 children with vitamin A deficiency, 647 (95.4%) had subclinical deficiency and 31 (4.6%) had clinical deficiency. There was no significant difference in vitamin A concentration between boys and girls, however girls had a significantly higher serum ferritin concentration than boys (P<0.05). The clinical vitamin A deficiency group had a significantly higher serum ferritin concentration than the subclinical vitamin A deficiency group and the normal group (P<0.05). In cases of vitamin A deficiency, the reduced iron storage group had significant reductions in mean corpuscular volume and mean corpuscular hemoglobin than the normal iron storage group (P<0.05). Compared with the normal vitamin A group, the vitamin A deficiency group had significantly lower hemoglobin concentration, mean corpuscular hemoglobin, red blood cell count, hematocrit, absolute reticulocyte count, reticulocyte percentage, and reticulocyte hemoglobin content, as well as a significantly higher mean corpuscular volume (P<0.05). Vitamin A deficiency is prevalent in preschool children

  19. Improvements in or relating to antibodies active against human hemoglobin Asub(1C)

    International Nuclear Information System (INIS)

    Javid, J.; Cerami, A.; Koenig, R.J.; Pettis, P.K.

    1980-01-01

    A method is described for preparing an antibody against human hemoglobin Asub(1c) which is substantially free of cross-reactivity against the human hemoglobins A 0 , Asub(1a) and Asub(1b). The antibodies are collected from cats, goats or sheep following injections of purified hemoglobin Asub(1c) antigen since these animals do not naturally produce hemoglobin Asub(1c). A radioimmunoassay method is also described whereby these antibodies are used to determine the quantity of hemoglobin Asub(1c) in blood samples. This is a useful technique in the diagnosis of diabetes mellitus. (U.K.)

  20. Relationship between serum 25-hydroxyvitamin D and red blood cell indices in German adolescents.

    Science.gov (United States)

    Doudin, Asmma; Becker, Andreas; Rothenberger, Aribert; Meyer, Thomas

    2018-04-01

    Since the impact of vitamin D on red blood cell formation has not been well studied, we aimed at assessing the putative link between serum 25-hydroxyvitamin D (25[OH]D) concentrations and hematological markers of erythropoiesis in a large cohort of German adolescents aged 11 to 17 years. In total, 5066 participants from the population-based, nationally representative KiGGS study (Kinder- und Jugendgesundheitssurvey, German Health Interview and Examination Survey for Children and Adolescents) were grouped into either tertiles or clinically accepted cutoff levels for serum 25(OH)D. Results demonstrated significant and inverse correlations between 25(OH)D levels and several hematological parameters including hemoglobin concentration (r = - 0.04, p = 0.003), mean corpuscular hemoglobin (r = - 0.11, p < 0.001), red blood cell count (r = - 0.04, p = 0.002), and soluble transferrin receptor (r = - 0.1, p < 0.001), whereas, in contrast, serum 25(OH)D was positively correlated to the mean corpuscular volume of erythrocytes (r = 0.08, p < 0.001). Multinomial regression models adjusted for clinically relevant confounders confirmed statistically significant differences between the two strata of 25(OH)D groups with respect to red blood cell markers (hemoglobin concentration, red blood cell count, mean corpuscular volume, and corpuscular hemoglobin, as well as iron and soluble transferrin receptor). The link between serum 25(OH)D and several important hematological parameters may point to an inhibitory role of vitamin D in the regulation of erythropoiesis in adolescents. What is Known: • The physiological effects of vitamin D on calcium homeostasis and bone metabolism have been established. • However, much less is known about the impact of circulating vitamin D on erythropoiesis. What is New: • Data from the KiGGS study in German adolescents demonstrated significant associations between serum vitamin D concentrations and red

  1. Non-invasive spectroscopy of transfusable red blood cells stored inside sealed plastic blood-bags.

    Science.gov (United States)

    Buckley, K; Atkins, C G; Chen, D; Schulze, H G; Devine, D V; Blades, M W; Turner, R F B

    2016-03-07

    After being separated from (donated) whole blood, red blood cells are suspended in specially formulated additive solutions and stored (at 4 °C) in polyvinyl chloride (PVC) blood-bags until they are needed for transfusion. With time, the prepared red cell concentrate (RCC) is known to undergo biochemical changes that lower effectiveness of the transfusion, and thus regulations are in place that limit the storage period to 42 days. At present, RCC is not subjected to analytical testing prior to transfusion. In this study, we use Spatially Offset Raman Spectroscopy (SORS) to probe, non-invasively, the biochemistry of RCC inside sealed blood-bags. The retrieved spectra compare well with conventional Raman spectra (of sampled aliquots) and are dominated by features associated with hemoglobin. In addition to the analytical demonstration that SORS can be used to retrieve RCC spectra from standard clinical blood-bags without breaking the sterility of the system, the data reveal interesting detail about the oxygenation-state of the stored cells themselves, namely that some blood-bags unexpectedly contain measurable amounts of deoxygenated hemoglobin after weeks of storage. The demonstration that chemical information can be obtained non-invasively using spectroscopy will enable new studies of RCC degeneration, and points the way to a Raman-based instrument for quality-control in a blood-bank or hospital setting.

  2. Performance and hemtochemical parameters of buck-kids fed concentrate partially replaced with tropical Piliostigma thonningii foliage.

    Science.gov (United States)

    Olafadehan, Olurotimi A; Njidda, Ahmed A; Okunade, Sunday A; Salihu, Sarah O; Balogun, David O; Salem, Abdelfattah Z M

    2018-02-01

    Fifteen 5-month-old Red Sokoto buck-kids, (6.6 ± 0.71 kg body weight (BW)) randomly distributed into three groups of five animals per group, were used to study the effects of supplementary concentrate partially replaced with Piliostigma thonningii (PT) foliage on the growth performance, economic benefit and blood profile in a completely randomized design using analysis of variance. The goats in group 1 received 100% supplementary concentrates (PT0), groups 2 and 3 received 25% (PT25) and 50% (PT50), respectively, of concentrate replaced with an equal amount (dry matter basis) of Piliostigma foliage. The goats were fed a basal diet of threshed sorghum top (TST). Intake of concentrate, hemoglobin, mean corpuscular hemoglobin concentration, mean corpuscular hemoglobin, total feeding cost and cost/kg BW were greater (P kids. © 2017 Japanese Society of Animal Science.

  3. Molecular characteristics of hemoglobins in blood clam and their immune responses to bacterial infection.

    Science.gov (United States)

    Xu, Bin; Zhang, Yanan; Jing, Zhao; Fan, Tingjun

    2017-06-01

    Bivalve hemoglobins have antibacterial activities, while the underlying mechanisms remain poorly understood. In our study, three full-length cDNAs of hemoglobins from blood clam skHbs were obtained, encoding putative polypeptides of 147, 150, and 152 amino acids, respectively. Predicted advanced protein structures showed that the skHbs had amphipathic antibacterial structures, displayed the typical structural characteristics of proteins with globin-like fold containing numerous alpha-helixes, and forming a homodimeric skHbI and a heterotetrameric skHbII complex. After injected with alive and heat-killed Gram-positive bacteria Bacillus subtilis, the mRNA levels of skHbI and skHbII were both significantly upregulated through increasing the expression of peptidoglycan recognition protein-like (PGRP-like) protein and Toll-like receptor (TLR-like) protein induced by peptidoglycan on the surface of the bacteria, but there were no obvious differences in their protein levels. Besides, reactive oxygen species (ROS) was detected to participate in the resistance to B. subtilis. These implied that skHbs could involve in the innate immune responses to Gram-positive bacterial infection directly with their amphipathic structures and indirectly by increasing ROS production through PGRP triggering Toll pathway. In conclusion, our findings reveal the structural characteristics of skHbs and their mechanism against Gram-positive bacteria thereby providing the molecular evidence for fundamental innate antibacterial activities by invoking respiratory proteins. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault-validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer.

    Science.gov (United States)

    Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela

    2018-05-01

    Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

  5. Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin.

    Science.gov (United States)

    Colquhoun, Douglas A; Forkin, Katherine T; Durieux, Marcel E; Thiele, Robert H

    2012-04-01

    The decision to administer blood products is complex and multifactorial. Accurate assessment of the concentration of hemoglobin [Hgb] is a key component of this evaluation. Recently a noninvasive method of continuously measuring hemoglobin (SpHb) has become available with multi-wavelength Pulse CO-Oximetry. The accuracy of this device is well documented, but the trending ability of this monitor has not been previously described. Twenty patients undergoing major thoracic and lumbar spine surgery were recruited. All patients received radial arterial lines. On the contralateral index finger, a R1 25 sensor (Rev E) was applied and connected to a Radical-7 Pulse CO-Oximeter (both Masimo Corp, Irvine, CA). Blood samples were drawn intermittently at the anesthesia provider's discretion and were analyzed by the operating room satellite laboratory CO-Oximeter. The value of Hgb and SpHb at that time point was compared. Trend analysis was performed by the four quadrant plot technique, testing directionality of change, and Critchley's polar plot method testing both directionality and magnitude of the change in values. Eighty-eight samples recorded at times of sufficient signal quality were available for analysis. Four quadrant plot analysis revealed 94% of data within the quadrants associated with the correct direction change, and 90% of data points lay within the analysis bounds proposed by Critchley. Pulse CO-Oximetry offers an acceptable trend monitor in patients undergoing major spine surgery. Future work should explore the ability of this device to detect large changes in hemoglobin, as well as its applicability in additional surgical and non-surgical patient populations.

  6. Optical sensor technology for a noninvasive continuous monitoring of blood components

    Science.gov (United States)

    Kraitl, Jens; Timm, Ulrich; Lewis, Elfed; Ewald, Hartmut

    2010-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) is used for a measurement of blood components. The absorptioncoefficient of blood differs at different wavelengths. This fact is used to calculate the optical absorbability characteristics of blood which is yielding information about blood components like hemoglobin (Hb), carboxyhemoglobin (CoHb) and arterial oxygen saturation (SpO2). The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. Hemoglobin is the main component of red blood cells. The primary function of Hb is the transport of oxygen from the lungs to the tissue and carbon dioxide back to the lungs. The Hb concentration in human blood is an important parameter in evaluating the physiological status of an individual and an essential parameter in every blood count. Currently, invasive methods are used to measure the Hb concentration, whereby blood is taken from the patient and subsequently analyzed. Apart from the discomfort of drawing blood samples, an added disadvantage of this method is the delay between the blood collection and its analysis, which does not allow real time patient monitoring in critical situations. A noninvasive method allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measured data.

  7. The impact of hemoglobin on the efficacy of phototherapy in hyperbilirubinemic infants

    DEFF Research Database (Denmark)

    Donneborg, Mette L; Vandborg, Pernille K; Hansen, Bo M

    2017-01-01

    BackgroundPhototherapy is the routine treatment for neonatal hyperbilirubinemia. Absorption of light in the skin transforms the native Z,Z-bilirubin to photobilirubins. This study investigates whether the hemoglobin concentration has an impact on efficacy of phototherapy, expressed by the decline...... decrease in TsB after 24 h was 121 (57-199) μmol/l; the median hemoglobin was 12.0 (7.0-14.7) mmol/l. There was a significant effect of hemoglobin concentration on the decrease in TsB of -3.61 μmol/mmol hemoglobin (P=0.022), after adjusting for initial TsB and postnatal age. That is, assuming the same...... initial TsB and postnatal age, for each mmol/l increase in hemoglobin, the decrease in TsB was 3.61 μmol/l smaller. In our hemoglobin range, the decrease in TsB is reduced by 28 μmol/l (23%).ConclusionIncreasing hemoglobin levels led to a decrease in the efficacy of phototherapy. Our data provide...

  8. Binding characteristics of arylamine, o-toluidine, in rodent blood proteins, hemoglobin and albumin

    International Nuclear Information System (INIS)

    DeBord, D.G.; Swearengin, T.F.; Booth-Jones, A.B.; Wissinger, L.A.

    1991-01-01

    o-Toluidine (OT), an arylamine used as an anti-oxidant in the tire and rubber industry, is a suspect human carcinogen. In order to develop a method for biological monitoring of OT, the authors have examined the binding characteristics of OT to the blood proteins, albumin (Alb) and hemoglobin (Hb). Male Sprague-Dawley rats were treated with 10, 20, 40, 50, or 100 mg/kg [ 14 C0]-OT ip and terminated at 2, 4, 8, 18, or 24 hrs. Alb and Hb were isolated from the blood. OT binding was determined by radioactivity associated with Alb and Hb. Maximum OT binding occurred at 4 hrs for Alb and 24 hrs for Hb. The radioactivity associated with Alb was 2x greater than that associated with Hb at 4 hrs, and approximately 30% greater at 24 hrs. Similar OT binding to Alb was observed at the 50 and 100 mg/kg doses, while for Hb maximum binding was seen at 100 mg/kg. Extended time points were studied to determine which blood protein would be more useful for biological monitoring purposes. Rats were treated with 100 mg/kg bw [ 14 C]-OT and terminated at 1, 2 and 4 wks. The remaining radioactivity associated with Alb was 12% after 1 wk, and < 2% after 2 and 4 wks. Conversely, the radioactivity associated with Hb was 64% after 1 wk, 52% by 2 wks, and 24% by 4 wks. These results suggest that Hb may be more useful than Alb as a biological monitoring tool for OT

  9. The narrow therapeutic window of glycated hemoglobin and assay variability.

    Science.gov (United States)

    Hosseini, S S; Bibler, I; Charles, M A

    1999-12-01

    Glycated hemoglobin is measured by a variety of assays, each of which has a unique normal level. Our purpose is to show that among the different assays available in the United States, using the same patient's blood sample, assay results may vary widely and may more or less easily achieve a glycated hemoglobin value within the normal range. The following assays were compared using the same patient's blood sample for each pair of assays: glycohemoglobin affinity assay (GHB Reader; Isolab, Akron, OH) versus gel electrophoresis assay (n = 76); Isolab versus ion capture assay (IMX; Abbott Laboratories, Irving, TX) (n = 57); monoclonal antibody assay (DCA2000; Bayer Diagnostics, Pittsburgh, PA) versus IMX (n = 100); and high-performance liquid chromatography (HPLC) assay (Bio-Rad Variant A1c; Bio-Rad Laboratories, Richmond, CA) versus IMX assay (n = 55). Our analyses indicate that a relative ranking can be established for the ease of achieving a normal glycated hemoglobin level. The ranking indicates that the most stringent or difficult assays for achieving a normal level are the Isolab and DCA2000 assays. The intermediate assays are the IMX and Bio-Rad Variant, and the easiest method for achieving a normal value is the gel electrophoresis assay. Our results indicate that various glycated hemoglobin assays vary widely and are associated with more or less difficulty for an individual patient to achieve a glycated hemoglobin level within the normal range. These results are especially significant with respect to (1) the clinically narrow therapeutic window of glycated hemoglobin values in type 1 diabetes to avoid rapidly advancing severe hypoglycemia rates and chronic microvascular complication rates, and (2) the glycated hemoglobin threshold for rapidly advancing macrovascular disease in both type 1 and type 2 patients.

  10. Absolute measurement of cerebral optical coefficients, hemoglobin concentration and oxygen saturation in old and young adults with near-infrared spectroscopy

    Science.gov (United States)

    We present near-infrared spectroscopy measurement of absolute cerebral hemoglobin concentration and saturation in a large sample of 36 healthy elderly (mean age, 85 ± 6 years) and 19 young adults (mean age, 28 ± 4 years). Non-invasive measurements were obtained on the forehead using a commercially a...

  11. Quantification of extra-cerebral and cerebral hemoglobin concentrations during physical exercise using time-domain near infrared spectroscopy

    OpenAIRE

    Auger, Héloïse; Bherer, Louis; Boucher, Étienne; Hoge, Richard; Lesage, Frédéric; Dehaes, Mathieu

    2016-01-01

    Fitness is known to have beneficial effects on brain anatomy and function. However, the understanding of mechanisms underlying immediate and long-term neurophysiological changes due to exercise is currently incomplete due to the lack of tools to investigate brain function during physical activity. In this study, we used time-domain near infrared spectroscopy (TD-NIRS) to quantify and discriminate extra-cerebral and cerebral hemoglobin concentrations and oxygen saturation (SO2) in young adults...

  12. Quality evaluation of four hemoglobin screening methods in a blood donor setting along with their comparative cost analysis in an Indian scenario

    Directory of Open Access Journals (Sweden)

    Tondon Rashmi

    2009-01-01

    Full Text Available Background: Despite the wide range of methods available for measurement of hemoglobin, no single technique has emerged as the most appropriate and ideal for a blood donation setup. Materials and Methods: A prospective study utilizing 1014 blood samples was carried out in a blood donation setting for quality evaluation of four methods of hemoglobin estimation along with cost analysis: Hematology cell analyzer (reference, HCS, CuSO4 method and HemoCue. Results: Mean value of HemoCue (mean ± SD = 14.7 ± 1.49 g/dl was higher by 0.24 compared to reference (mean ± SD = 13.8 ± 1.52 g/dl but not statistically significant ( P > 0.05. HemoCue proved to be the best technique (sensitivity 99.4% and specificity 84.4% whereas HCS was most subjective with 25.2% incorrect estimations. CuSO4 proved to be good with 7.9% false results. Comparative cost analysis of each method was calculated to be 35 INR/test for HemoCue, 0.76 INR /test for HCS and 0.06-0.08 INR /test for CuSO4. Conclusion: CuSO4 method gives accurate results, if strict quality control is applied. HemoCue is too expensive to be used as a primary screening method in an economically restricted country like India.

  13. Theoretical model for optical oximetry at the capillary level: exploring hemoglobin oxygen saturation through backscattering of single red blood cells

    Science.gov (United States)

    Liu, Rongrong; Spicer, Graham; Chen, Siyu; Zhang, Hao F.; Yi, Ji; Backman, Vadim

    2017-02-01

    Oxygen saturation (sO2) of red blood cells (RBCs) in capillaries can indirectly assess local tissue oxygenation and metabolic function. For example, the altered retinal oxygenation in diabetic retinopathy and local hypoxia during tumor development in cancer are reflected by abnormal sO2 of local capillary networks. However, it is far from clear whether accurate label-free optical oximetry (i.e., measuring hemoglobin sO2) is feasible from dispersed RBCs at the single capillary level. The sO2-dependent hemoglobin absorption contrast present in optical scattering signal is complicated by geometry-dependent scattering from RBCs. We present a numerical study of backscattering spectra from single RBCs based on the first-order Born approximation, considering practical factors: RBC orientations, size variation, and deformations. We show that the oscillatory spectral behavior of RBC geometries is smoothed by variations in cell size and orientation, resulting in clear sO2-dependent spectral contrast. In addition, this spectral contrast persists with different mean cellular hemoglobin content and different deformations of RBCs. This study shows for the first time the feasibility of, and provides a theoretical model for, label-free optical oximetry at the single capillary level using backscattering-based imaging modalities, challenging the popular view that such measurements are impossible at the single capillary level.

  14. High-altitude adaptations in vertebrate hemoglobins

    DEFF Research Database (Denmark)

    Weber, Roy E.

    2007-01-01

    Vertebrates at high altitude are subjected to hypoxic conditions that challenge aerobic metabolism. O2 transport from the respiratory surfaces to tissues requires matching between the O2 loading and unloading tensions and theO2-affinity of blood, which is an integrated function of hemoglobin......, birds and ectothermic vertebrates at high altitude....

  15. Etiology of anemia of blood donor candidates deferred by hematologic screening

    Directory of Open Access Journals (Sweden)

    Michel Alves da Silva

    2012-01-01

    Full Text Available OBJECTIVE: Iron deficiency is the most common cause of anemia and one of the main factors in the clinical deferral of blood donors. This fact prompted the current study that aimed to determine the prevalence and etiology of anemia in blood donor candidates and to evaluate the hematological screening technique used for the exclusion of these donors. METHODS: This was a prospective study that compared two groups (Anemic and Non-anemic. Initially screening for anemia was performed by manually measuring hemoglobin (Bioclin® Kit; the results were subsequently compared with an automated screening method (Coulter T-890. The etiology was investigated by hemoglobin electrophoresis in alkaline and acid pH, Hb A2 dosage and measurement of the ferritin concentration by immunoagglutination. Differences and associations of interest were analyzed using the Yates and McNemar's Chi-square tests and the Fisher, Mann-Whitney, Wilcoxon and Kruskal-Wallis tests. RESULTS: The deferral rate due to anemia was 4.2%; iron deficiency was identified in 37.5% and beta thalassemia in 9.3% of the excluded candidates. There was a significant discrepancy between the two techniques used to measure hemoglobin with 38.1% of initially deferred donors presenting normal hemoglobin levels by the automated method. CONCLUSION: The results show a high rate of blood donors being deferred for anemia and confirm that iron deficiency is the most prevalent cause. The discrepancies found by comparing screening methods suggest that hemoglobin and hematocrit levels should be confirmed before deferring a donor due to anemia; this may increase supplies in blood banks.

  16. Fetal hemoglobin is much less prone to DNA cleavage compared to the adult protein

    Directory of Open Access Journals (Sweden)

    Sandeep Chakane

    2017-08-01

    Full Text Available Hemoglobin (Hb is well protected inside the red blood cells (RBCs. Upon hemolysis and when free in circulation, Hb can be involved in a range of radical generating reactions and may thereby attack several different biomolecules. In this study, we have examined the potential damaging effects of cell-free Hb on plasmid DNA (pDNA. Hb induced cleavage of supercoiled pDNA (sc pDNA which was proportional to the concentration of Hb applied. Almost 70% of sc pDNA was converted to open circular or linear DNA using 10 µM of Hb in 12 h. Hb can be present in several different forms. The oxy (HbO2 and met forms are most reactive, while the carboxy-protein shows only low hydrolytic activity. Hemoglobin A (HbA could easily induce complete pDNA cleavage while fetal hemoglobin (HbF was three-fold less reactive. By inserting, a redox active cysteine residue on the surface of the alpha chain of HbF by site-directed mutagenesis, the DNA cleavage reaction was enhanced by 82%. Reactive oxygen species were not directly involved in the reaction since addition of superoxide dismutase and catalase did not prevent pDNA cleavage. The reactivity of Hb with pDNA can rather be associated with the formation of protein based radicals. Keywords: Adult hemoglobin, Fetal hemoglobin, Supercoiled plasmid DNA, DNA cleavage, Cysteine, Protein radicals

  17. Concurrent measurement of cellular turbidity and hemoglobin to evaluate the antioxidant activity of plants.

    Science.gov (United States)

    Bellik, Yuva; Iguer-Ouada, Mokrane

    2016-01-01

    In past decades, a multitude of analytical methods for measuring antioxidant activity of plant extracts has been developed. However, when using methods to determine hemoglobin released from human erythrocytes treated with ginger extracts, we found hemoglobin concentrations were significantly higher than in untreated control samples. This suggests in the presence of antioxidants that measuring hemoglobin alone is not sufficient to determine hemolysis. We show concurrent measurement of erythrocyte concentration and hemoglobin is essential in such assays, and describe a new protocol based on simultaneous measurement of cellular turbidity and hemoglobin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Effect of Resistance Training on Hematological Blood Markers in Older Men and Women: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Florian Bobeuf

    2009-01-01

    Full Text Available The aim of this study was to examine the effects of resistance training on hematological blood markers in older individuals. Twenty-nine men and women participated to this study. Subjects were randomized in 2 groups: (1 control (n=13 and (2 resistance training (n=16. At baseline and after the intervention, subjects were submitted to a blood sample to determine their hematological profile (red blood cells, hemoglobin, hematocrit, platelets, leukocytes, neutrophils, lymphocytes, monocytes, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, red cell distribution width. At baseline, no difference was observed between groups. Moreover, we found no significant difference after the intervention on any of these markers. A 6-month resistance program in healthy older individuals seems to have no beneficial nor deleterious effects on hematological blood parameters. However, resistance training was well tolerated and should be recommended for other health purposes. Further studies are needed to confirm these results in a large population.

  19. Hemoglobin concentrations in 358 apparently healthy 80-year-old Danish men and women. Should the reference interval be adjusted for age?

    DEFF Research Database (Denmark)

    Milman, N.; Pedersen, Agnes Nadelmann; Ovesen, Lars

    2008-01-01

    Background and aims: In elderly Danes, reference intervals for hemoglobin (Hb) concentrations are derived from younger population groups. The aim was to examine reference intervals for Hb and cut-off limits for anemia by application of criteria for normality to a representative population of 80...

  20. Transient spontaneous engraftment of CD34 hematopoietic cord blood stem cells as seen in peripheral blood: treatment of leprosy patients with anemia by placental umbilical cord whole blood transfusion.

    Science.gov (United States)

    Bhattacharya, N

    2006-01-01

    Cord blood, because of its rich mix of fetal and adult hemoglobin, high platelet and white blood cell (WBC) counts, and a plasma filled with cytokine and growth factors, as well as its hypoantigenic nature and altered metabolic profile, has all the potential of a real and safe alternative to adult blood transfusion. Our experience of 74 units (50 ml-146 ml mean, 86 ml +/- 7.6 ml SD, median 80 ml, mean packed cell volume 48 +/- 4.1 SD, mean percent hemoglobin concentration 16.2 g/dl +/- 1.8 g/dl of placental umbilical cord whole blood collection (from 1 April 1999) after lower uterine cesarean section (LUCS) from consenting mothers and transfusion of the same to 16 informed, consenting patients with percent plasma hemoglobin 8 g/dl or less, is presented here. After collection the blood was immediately preserved in the refrigerator and transfused within 72 hours of collection. Fifteen males and one female, aged 12-72 yrs (mean 48.4 yrs) participated: five cases were pausibacillary type (PB) and 11 cases were multibacillary type (MB). The clinical spectrum of the cases varied widely from the tuberculoid to the lepromatous type and one patient presented with gangrene of the leg preceding an auto amputation which was infested with maggots. Each case was approved by the institutional ethical committee and received two to eight units of freshly collected placental umbilical cord blood in one transfusion without encountering any clinical, immunological or non-immunological reaction. Seven days after completion of the placental umbilical cord blood transfusion, the peripheral blood hematopoietic stem cell (CD34) estimation revealed a rise from the pretransfusion base level (.09%), varying from 3.6% to 16.2%, in 75% of the cases, without provoking any clinical graft vs host reaction in any of the leprosy victims. This value returned to normal within three months in most cases.

  1. Polynitroxylated Pegylated Hemoglobin-A Novel, Small Volume Therapeutic for Traumatic Brain Injury Resuscitation: Comparison to Whole Blood and Dose Response Evaluation.

    Science.gov (United States)

    Brockman, Erik C; Jackson, Travis C; Dixon, C Edward; Bayɪr, Hülya; Clark, Robert S B; Vagni, Vincent; Feldman, Keri; Byrd, Catherine; Ma, Li; Hsia, Carleton; Kochanek, Patrick M

    2017-04-01

    Resuscitation with polynitroxylated pegylated hemoglobin (PNPH), a pegylated bovine hemoglobin decorated with nitroxides, eliminated the need for fluid administration, reduced intracranial pressure (ICP) and brain edema, and produced neuroprotection in vitro and in vivo versus Lactated Ringer's solution (LR) in experimental traumatic brain injury (TBI) plus hemorrhagic shock (HS). We hypothesized that resuscitation with PNPH would improve acute physiology versus whole blood after TBI+HS and would be safe and effective across a wide dosage range. Anesthetized mice underwent controlled cortical impact and severe HS to mean arterial pressure (MAP) of 25-27 mm Hg for 35 min, then were resuscitated with PNPH, autologous whole blood, or LR. Markers of acute physiology, including mean arterial blood pressure (MAP), heart rate (HR), blood gases/chemistries, and brain oxygenation (PbtO 2 ), were monitored for 90 min on room air followed by 15 min on 100% oxygen. In a second experiment, the protocol was repeated, except mice were resuscitated with PNPH with doses between 2 and 100 mL/kg. ICP and 24 h %-brain water were evaluated. PNPH-resuscitated mice had higher MAP and lower HR post-resuscitation versus blood or LR (p < 0.01). PNPH-resuscitated mice, versus those resuscitated with blood or LR, also had higher pH and lower serum potassium (p < 0.05). Blood-resuscitated mice, however, had higher PbtO 2 versus those resuscitated with LR and PNPH, although PNPH had higher PbtO 2 versus LR (p < 0.05). PNPH was well tolerated across the dosing range and dramatically reduced fluid requirements in all doses-even 2 or 5 mL/kg (p < 0.001). ICP was significantly lower in PNPH-treated mice for most doses tested versus in LR-treated mice, although %-brain water did not differ between groups. Resuscitation with PNPH, versus resuscitation with LR or blood, improved MAP, HR, and ICP, reduced acidosis and hyperkalemia, and was well tolerated and effective

  2. Plant hemoglobins: Important players at the crossroads between oxygen and nitric oxide

    DEFF Research Database (Denmark)

    Gupta, Kapuganti J; Hebelstrup, Kim; Mur, Luis A J

    2011-01-01

    Plant hemoglobins constitute a diverse group of hemeproteins and evolutionarily belong to three different classes. Class 1 hemoglobins possess an extremely high affinity to oxygen and their main function consists in scavenging of nitric oxide (NO) at very low oxygen levels. Class 2 hemoglobins have...... at high O2 concentrations. Depending on their physical properties, hemoglobins belong either to hexacoordinate non-symbiotic or pentacoordinate symbiotic groups. Plant hemoglobins are plausible targets for improving resistance to multiple stresses....

  3. Identification of a Hemolysis Threshold That Increases Plasma and Serum Zinc Concentration.

    Science.gov (United States)

    Killilea, David W; Rohner, Fabian; Ghosh, Shibani; Otoo, Gloria E; Smith, Lauren; Siekmann, Jonathan H; King, Janet C

    2017-06-01

    Background: Plasma or serum zinc concentration (PZC or SZC) is the primary measure of zinc status, but accurate sampling requires controlling for hemolysis to prevent leakage of zinc from erythrocytes. It is not established how much hemolysis can occur without changing PZC/SZC concentrations. Objective: This study determines a guideline for the level of hemolysis that can significantly elevate PZC/SZC. Methods: The effect of hemolysis on PZC/SZC was estimated by using standard hematologic variables and mineral content. The calculated hemolysis threshold was then compared with results from an in vitro study and a population survey. Hemolysis was assessed by hemoglobin and iron concentrations, direct spectrophotometry, and visual assessment of the plasma or serum. Zinc and iron concentrations were determined by inductively coupled plasma spectrometry. Results: A 5% increase in PZC/SZC was calculated to result from the lysis of 1.15% of the erythrocytes in whole blood, corresponding to ∼1 g hemoglobin/L added into the plasma or serum. Similarly, the addition of simulated hemolysate to control plasma in vitro caused a 5% increase in PZC when hemoglobin concentrations reached 1.18 ± 0.10 g/L. In addition, serum samples from a population nutritional survey were scored for hemolysis and analyzed for changes in SZC; samples with hemolysis in the range of 1-2.5 g hemoglobin/L showed an estimated increase in SZC of 6% compared with nonhemolyzed samples. Each approach indicated that a 5% increase in PZC/SZC occurs at ∼1 g hemoglobin/L in plasma or serum. This concentration of hemoglobin can be readily identified directly by chemical hemoglobin assays or indirectly by direct spectrophotometry or matching to a color scale. Conclusions: A threshold of 1 g hemoglobin/L is recommended for PZC/SZC measurements to avoid increases in zinc caused by hemolysis. The use of this threshold may improve zinc assessment for monitoring zinc status and nutritional interventions.

  4. The homeostasis of Plasmodium falciparum-infected red blood cells.

    Directory of Open Access Journals (Sweden)

    Jakob M A Mauritz

    2009-04-01

    Full Text Available The asexual reproduction cycle of Plasmodium falciparum, the parasite responsible for severe malaria, occurs within red blood cells. A merozoite invades a red cell in the circulation, develops and multiplies, and after about 48 hours ruptures the host cell, releasing 15-32 merozoites ready to invade new red blood cells. During this cycle, the parasite increases the host cell permeability so much that when similar permeabilization was simulated on uninfected red cells, lysis occurred before approximately 48 h. So how could infected cells, with a growing parasite inside, prevent lysis before the parasite has completed its developmental cycle? A mathematical model of the homeostasis of infected red cells suggested that it is the wasteful consumption of host cell hemoglobin that prevents early lysis by the progressive reduction in the colloid-osmotic pressure within the host (the colloid-osmotic hypothesis. However, two critical model predictions, that infected cells would swell to near prelytic sphericity and that the hemoglobin concentration would become progressively reduced, remained controversial. In this paper, we are able for the first time to correlate model predictions with recent experimental data in the literature and explore the fine details of the homeostasis of infected red blood cells during five model-defined periods of parasite development. The conclusions suggest that infected red cells do reach proximity to lytic rupture regardless of their actual volume, thus requiring a progressive reduction in their hemoglobin concentration to prevent premature lysis.

  5. A new polyethyleneglycol-derivatized hemoglobin derivative with decreased oxygen affinity and limited toxicity.

    Science.gov (United States)

    Zolog, Oana; Mot, Augustin; Deac, Florina; Roman, Alina; Fischer-Fodor, Eva; Silaghi-Dumitrescu, Radu

    2011-01-01

    A new protocol is described for derivatization of hemoglobin with polyethyleneglycol (PEG) via reaction of the unmodified native hemoglobin with an activated amine-reacting polyethylene glycol derivative which, unlike protocols previously described, leads to formation of a peptide bond between hemoglobin and PEG. Dioxygen binding and peroxide reactivities of the derivatized hemoglobin are examined, and found to be within reasonable limits, with the particular observation that, unlike with a few other derivatization protocols, the dioxygen affinity is slightly lower than that of native Hb. In cell culture tests (human umbilical vein epithelial cells, HUVEC), the derivatization protocol induces no toxic effect. These results show promise towards applicability for production of hemoglobin-based blood substitutes.

  6. Simultaneous estimation of transcutaneous bilirubin, hemoglobin, and melanin based on diffuse reflectance spectroscopy

    Science.gov (United States)

    Nishidate, Izumi; Abdul, Wares MD.; Ohtsu, Mizuki; Nakano, Kazuya; Haneishi, Hideaki

    2018-02-01

    We propose a method to estimate transcutaneous bilirubin, hemoglobin, and melanin based on the diffuse reflectance spectroscopy. In the proposed method, the Monte Carlo simulation-based multiple regression analysis for an absorbance spectrum in the visible wavelength region (460-590 nm) is used to specify the concentrations of bilirubin (Cbil), oxygenated hemoglobin (Coh), deoxygenated hemoglobin (Cdh), and melanin (Cm). Using the absorbance spectrum calculated from the measured diffuse reflectance spectrum as a response variable and the extinction coefficients of bilirubin, oxygenated hemoglobin, deoxygenated hemoglobin, and melanin, as predictor variables, multiple regression analysis provides regression coefficients. Concentrations of bilirubin, oxygenated hemoglobin, deoxygenated hemoglobin, and melanin, are then determined from the regression coefficients using conversion vectors that are numerically deduced in advance by the Monte Carlo simulations for light transport in skin. Total hemoglobin concentration (Cth) and tissue oxygen saturation (StO2) are simply calculated from the oxygenated hemoglobin and deoxygenated hemoglobin. In vivo animal experiments with bile duct ligation in rats demonstrated that the estimated Cbil is increased after ligation of bile duct and reaches to around 20 mg/dl at 72 h after the onset of the ligation, which corresponds to the reference value of Cbil measured by a commercially available transcutaneous bilirubin meter. We also performed in vivo experiments with rats while varying the fraction of inspired oxygen (FiO2). Coh and Cdh decreased and increased, respectively, as FiO2 decreased. Consequently, StO2 was dramatically decreased. The results in this study indicate potential of the method for simultaneous evaluation of multiple chromophores in skin tissue.

  7. Identificação de variantes de hemoglobina em doadores de sangue Identification of hemoglobin variants in blood donor

    Directory of Open Access Journals (Sweden)

    Ana C. Bonini-Domingos

    2004-03-01

    Full Text Available Hemoglobinopathies are the most common genetic diseases and affect a great number of individuals in the world, with diverse clinical complications ranging from the almost unnoticeable to lethal consequences. In Brazil the occurrence of hemoglobinopathies is very frequent and influenced by the ethnical groups that are the basis of populations in different regions. The phenotype may be influenced by environmental and genetic factors and by migration. An understanding of these genetic diseases is important for the health and quality of life of the population. In this work we assessed the presence of Hb variants in blood donors from São José do Rio Preto and region, and we observed the occurrence of variants including Hb S and Hb C but in particular the so-called "S-Like" variants. Good determination of the forms of variant hemoglobins is very important to give better guidance to blood donors and their families, and to improve the quality of blood transfusion.

  8. Six-day stability of erythrocyte and reticulocyte parameters in-vitro: a comparison of blood samples from healthy, iron-deficient, and thalassemic individuals.

    Science.gov (United States)

    Sudmann-Day, Åshild A; Piehler, Armin; Klingenberg, Olav; Urdal, Petter

    2015-05-01

    Stability for up to 6 days' storage of erythrocyte and reticulocyte parameters in samples from iron-deficient and thalassemic individuals has not yet been reported. This lack of knowledge challenges evaluation of the full blood count in referral samples for hemoglobinopathy evaluation. We therefore hereby present such sample stability data. We included fresh (less than 4 hours old) blood samples from eight healthy, eight iron-deficient, and 11 thalassemic individuals. A full blood count, including reticulocyte parameters, was performed on a Sysmex XE-2100 once daily during a 6-day storage period at room temperature. For healthy individuals, we also studied stability of refrigerated samples and investigated analytical and biological variation. Hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin were stable for 6 days in all diagnostic groups. Mean corpuscular volume increased less in samples from iron-deficient individuals while the number of reticulocytes increased more in samples from thalassemic, as compared to healthy individuals. Ret-He stability depended on its baseline value. Within-person biological variation in samples from healthy individuals was low both for erythrocyte parameters and for reticulocyte hemoglobin, while higher for reticulocyte counts. Results for hemoglobin concentration, erythrocyte count, and mean corpuscular hemoglobin are reliable in hemoglobinopathy investigation of referred samples for up to 6 days. Storage time-dependent changes of other erythrocyte and reticulocyte parameters in blood samples from iron-deficient and thalassemic individuals differ from those of healthy individuals.

  9. The dual roles of red blood cells in tissue oxygen delivery

    DEFF Research Database (Denmark)

    Jensen, Frank Bo

    2009-01-01

    Vertebrate red blood cells (RBCs) seem to serve tissue oxygen delivery in two distinct ways. Firstly, RBCs enable the adequate transport of O2 between respiratory surfaces and metabolizing tissues by means of their high intracellular concentration of hemoglobin (Hb), appropriate allosteric...

  10. Impact of hemoglobin nitrite to nitric oxide reductase on blood transfusion for resuscitation from hemorrhagic shock

    Directory of Open Access Journals (Sweden)

    Chad Brouse

    2015-01-01

    Full Text Available Background: Transfusion of blood remains the gold standard for fluid resuscitation from hemorrhagic shock. Hemoglobin (Hb within the red blood cell transports oxygen and modulates nitric oxide (NO through NO scavenging and nitrite reductase. Aims: This study was designed to examine the effects of incorporating a novel NO modulator, RRx-001, on systemic and microvascular hemodynamic response after blood transfusion for resuscitation from hemorrhagic shock in a hamster window chamber model. In addition, to RRx-001 the role of low dose of nitrite (1 × 10−9 moles per animal supplementation after resuscitation was studied. Materials and Methods: Severe hemorrhage was induced by arterial controlled bleeding of 50% of the blood volume (BV and the hypovolemic state was maintained for 1 h. The animals received volume resuscitation by an infusion of 25% of BV using fresh blood alone or with added nitrite, or fresh blood treated with RRx-001 (140 mg/kg or RRx-001 (140 mg/kg with added nitrite. Systemic and microvascular hemodynamics were followed at baseline and at different time points during the entire study. Tissue apoptosis and necrosis were measured 8 h after resuscitation to correlate hemodynamic changes with tissue viability. Results: Compared to resuscitation with blood alone, blood treated with RRx-001 decreased vascular resistance, increased blood flow and functional capillary density immediately after resuscitation and preserved tissue viability. Furthermore, in RRx-001 treated animals, both mean arterial pressure (MAP and met Hb were maintained within normal levels after resuscitation (MAP >90 mmHg and metHb <2%. The addition of nitrite to RRx-001 did not significantly improve the effects of RRx-001, as it increased methemoglobinemia and lower MAP. Conclusion: RRx-001 alone enhanced perfusion and reduced tissue damage as compared to blood; it may serve as an adjunct therapy to the current gold standard treatment for resuscitation from

  11. Radioprotective properties of some heterocyclic nitrogenous compounds against changes in hemoglobin concentration and hematocrit value in x-irradiated mice; Proprietes radioprotectrices de certains composes heterocycliques azotes sur les variations du taux d'hemoglobine et de la valeur hematocrite chez la souris irradiee

    Energy Technology Data Exchange (ETDEWEB)

    Rousdhy, H; Pierotti, T; Polverelli, M [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1969-07-01

    Radioprotective properties of imidazole and benzimidazole have been proved in previous works. In this study, authors try to demonstrate radioprotective action of these compounds in comparison with cysteamine upon the hematopoietic system after lethal X-irradiation. Results show: no drastic variations of hematologic constants (hemoglobin concentration and hematocrit value) after intraperitoneal injection of radioprotective compounds apart certain apparent reactions with the heterocyclic compounds; the better radioprotective action of benzimidazole. Twenty five days after irradiation, hemoglobin concentration and hematocrit of radio protected mice return to normal values. (author) [French] Les proprietes radioprotectrices de l'imidazole et du benzimidazole ayant ete demontrees dans de precedents travaux, les auteurs se sont attaches a etudier l'action de ces produits sur le systeme hematopofetique en comparaison avec celle de la cysteamine, apres une irradiation a dose letale. A l'aide des criteres choisis, les resultats demontrent: qu'en dehors de certaines reactions apparentes, succedant a l'injection intraperitoneale des heterocycles azotes, les constantes hematologiques (taux d'hemoglobine et valeur hematocrite) ne sont que legerement modifiees; la superiorite du benzimidazole sur les autres produits utilises. Enfin, le vingt-cinquieme jour apres irradiation, les souris protegees par les heterocycles azotes ont un taux d'hemoglobine et une valeur hematocrite tout a fait normaux. (auteur)

  12. Packed red blood cell transfusion causes greater hemoglobin rise at a lower starting hemoglobin in patients with subarachnoid hemorrhage.

    Science.gov (United States)

    Naidech, Andrew M; Kahn, Marc J; Soong, Wayne; Green, David; Batjer, H Hunt; Bleck, Thomas P

    2008-01-01

    Each unit of packed red blood cells (PRBCs) is expected to raise circulating hemoglobin (HGB) by approximately 1 g/dL. There are few data on modifiers of this relationship other than gender and body mass index (BMI). We recorded HGB before and after PRBC transfusion in a retrospective cohort of 103 patients and a prospective cohort of 93 patients with subarachnoid hemorrhage (SAH). In the retrospective cohort, 48 of 103 patients were transfused, and in the prospective cohort, 56 of 93 patients were transfused. In both groups, lower pre-transfusion HGB was associated with a larger increase in HGB (P rise in HGB (P < 0.001) after correction for number of units of PRBCs given, gender, and BMI in repeated measures analysis. Pre-transfusion HGB explained an additional 12% of variance in the data (P < 0.001). In both cohorts, the magnitude of the effect was similar. In patients with SAH, transfusion at lower HGB leads to a greater increase in HGB. Transfusion at lower HGB may be relatively more cost-effective, and this should be balanced against any potential benefit from higher HGB in SAH. One rather than 2 units of PRBCs are likely to be sufficient for most HGB targets after SAH, especially in patients with more severe anemia.

  13. Postmortem Femoral Blood Concentrations of Risperidone

    DEFF Research Database (Denmark)

    Linnet, Kristian; Johansen, Sys Stybe

    2014-01-01

    Postmortem femoral blood concentrations of the antipsychotic drug risperidone and the active metabolite 9-hydroxyrisperidone were determined by an achiral LC-MS/MS method in 38 cases. The cause of death was classified as unrelated to risperidone in 30 cases, in which the sum of the concentration ...

  14. Therapeutic effect of forearm low level light treatment on blood flow, oxygenation, and oxygen consumption

    Science.gov (United States)

    Wang, Pengbo; Sun, Jiajing; Meng, Lingkang; Li, Zebin; Li, Ting

    2018-02-01

    Low level light/laser therapy (LLLT) is considered as a novel, non-invasive, and potential therapy in a variety of psychological and physical conditions, due to its effective intricate photobiomodulation. The mechanism of LLLT is that when cells are stimulated by photons, mitochondria produce a large quantity of ATP, which accelerates biochemical responses in the cell. It is of great significance to gain a clear insight into the change or interplay of various physiological parameters. In this study, we used functional near-infrared spectroscopy (fNIRS) and venous-occlusion plethysmography to measure the LLLT-induced changes in blood flow, oxygenation, and oxygen consumption in human forearms in vivo. Six healthy human participants (4 males and 2 females) were administered with 810-nm light emitted by LED array in ten minutes and blood flow, oxygenation and oxygen consumption were detected in the entire experiment. We found that LLLT induced an increase of blood flow and oxygen consumption on the treated site. Meanwhile, LLLT took a good role in promoting oxygenation of regional tissue, which was indicated by a significant increase of oxygenated hemoglobin concentration (Δ[HbO2]), a nearly invariable deoxygenated hemoglobin concentration (Δ[Hb]) and a increase of differential hemoglobin concentration (Δ[HbD] = Δ[HbO2] - Δ[Hb]). These results not only demonstrate enormous potential of LLLT, but help to figure out mechanisms of photobiomodulation.

  15. Correlates of whole-blood polyunsaturated fatty acids among young children with moderate acute malnutrition.

    Science.gov (United States)

    Yaméogo, C W; Cichon, B; Fabiansen, C; Rytter, M J H; Faurholt-Jepsen, D; Stark, K D; Briend, A; Shepherd, S; Traoré, A S; Christensen, V B; Michaelsen, K F; Friis, H; Lauritzen, L

    2017-07-13

    Severe acute malnutrition (SAM) has been associated with low polyunsaturated fatty acid (PUFA) status. However, investigations regarding PUFA status and correlates in children with moderate acute malnutrition (MAM) from low-income countries are scarce. The aim of this study was to describe whole-blood PUFA levels in children with moderate acute malnutrition (MAM) and to identify correlates of PUFAs. We conducted a cross-sectional study using baseline data from a prospective nutritional intervention trial among 1609 children with MAM aged 6-23 months in Burkina Faso,West Africa. Whole-blood PUFAs were measured by gas chromatography and expressed as percent of total whole-blood fatty acids (FA%). Potential correlates of PUFAs including infection, inflammation, hemoglobin, anthropometry (difference between children diagnosed as having MAM based on low mid-upper-arm-circumference (MUAC) only, low MUAC and weight-for-height z-score (WHZ), or low WHZ only) and diet were assessed by linear regression adjusted for age and sex. Children with MAM had low concentrations of whole-blood PUFAs, particularly n-3 PUFAs. Moreover, children diagnosed with MAM based only on low MUAC had 0.32 (95% confidence interval (CI), 0.14; 0.50) and 0.40 (95% CI, 0.16; 0.63) FA% lower arachidonic acid (AA) than those recruited based on both low WHZ as well as low MUAC and those recruited with low WHZ only, respectively. Infection and inflammation were associated with low levels of all long-chain (LC)-PUFAs, while hemoglobin was positively associated with whole-blood LC-PUFAs. While PUFA deficiency was not a general problem, overall whole-blood PUFA concentrations, especially of n-3 PUFAs, were low. Infection, inflammation, hemoglobin, anthropometry and diet were correlates of PUFAs concentrations in children with MAM. The trial is registered at http://www.isrctn.com ( ISRCTN42569496 ).

  16. Mechanisms of the adjuvant effect of hemoglobin in experimental peritonitis. VII. Hemoglobin does not inhibit clearance of Escherichia coli from the peritoneal cavity

    International Nuclear Information System (INIS)

    Dunn, D.L.; Barke, R.A.; Lee, J.T. Jr.; Condie, R.M.; Humphrey, E.W.; Simmons, R.L.

    1983-01-01

    Hemoglobin has been shown to be a potent adjuvant in experimental Escherichia coli peritonitis, although a satisfactory mechanistic rationale is still obscure. Hemoglobin has been thought to impair intraperitoneal neutrophil function, delay clearance of bacteria from the peritoneal cavity by the normal absorptive mechanisms, or directly enhance bacterial growth. Using highly purified stroma-free hemoglobin (SFHgb), we have largely discounted any direct effect of hemoglobin on peritoneal white blood cell function. In the present study, we confirmed that uncontrolled proliferation of bacteria takes place in the presence of hemoglobin in the peritoneal cavity. Nonviable 5-iododeoxyuridine 125 I-labelled bacteria were then used to directly study peritoneal clearance kinetics, eliminating the problem of bacterial growth. SFHgb had no influence on the removal of intraperitoneal bacteria. The rate of bloodstream appearance of radiolabel was similar with or without intraperitoneal SFHgb. Thus, SFHgb does not prevent clearance of bacteria from the peritoneal cavity by interfering with normal host clearance mechanisms. SFHgb may act as a bacterial growth adjuvant, either by serving as a bacterial nutrient or by suitably modifying the environment so that extensive bacterial proliferation can occur. The latter hypothesis appears to be an area in which investigation concerning the adjuvant effect of hemoglobin may prove most fruitful

  17. Residual blood processing by centrifugation, cell salvage or ultrafiltration in cardiac surgery: effects on clinical hemostatic and ex-vivo rheological parameters.

    Science.gov (United States)

    Vonk, Alexander B; Muntajit, Warayouth; Bhagirath, Pranav; van Barneveld, Laurentius J; Romijn, Johannes W; de Vroege, Roel; Boer, Christa

    2012-10-01

    The study compared the effects of three blood concentration techniques after cardiopulmonary bypass on clinical hemostatic and ex-vivo rheological parameters. Residual blood of patients undergoing elective cardiac surgery was processed by centrifugation, cell salvage or ultrafiltration, and retransfused (n = 17 per group). Study parameters included blood loss, (free) hemoglobin, hematocrit, fibrinogen and erythrocyte aggregation, deformability and 2,3-diphosphoglycerate content. Patient characteristics were similar between groups. Ultrafiltration was associated with the highest weight of the transfusion bag [649 ± 261 vs. 320 ± 134 g (centrifugation) and 391 ± 158 g (cell salvage); P levels in the transfusion bag. Retransfusion of cell saver blood induced the largest gain in postoperative patient hemoglobin levels when compared to centrifugation and ultrafiltration, and was associated with the largest increase in 2,3-diphosphoglycerate when compared to ultrafiltration (Δ2,3-diphosphoglycerate 1.34 ± 1.92 vs. -0.77 ± 1.56 mmol/l; P = 0.03). Cell salvage is superior with respect to postoperative hemoglobin gain and washout of free hemoglobin when compared to centrifugation or ultrafiltration.

  18. Role of Breastfeeding and Complementary Food on Hemoglobin and Ferritin Levels in a Cambodian Cross-Sectional Sample of Children Aged 3 to 24 Months.

    Directory of Open Access Journals (Sweden)

    Anika Reinbott

    Full Text Available Iron deficiency derives from a low intake of dietary iron, poor absorption of iron, and high requirements due to growth as well as blood loss. An estimated number of about 50% of all anemia may be attributed to iron deficiency among young children in Cambodia.A cross-sectional survey was conducted in rural Cambodia in September 2012. Villages in pre-selected communes were randomly chosen using stunting as a primary indicator of nutritional status. In total, 928 randomly selected households with children aged 3-23 months were included. Hemoglobin, ferritin, soluble transferrin receptor (sTfR, and retinol binding protein (RBP were assessed from capillary blood samples. In addition, length/height and weight of mothers and children were taken and data on dietary diversity was collected. A child feeding index (CFI was created. Associations between biomarkers of iron and vitamin A status and nutritional status or food intake were explored.Anemia prevalence was highest among 6- to 12-months-olds (71%. Ferritin and sTfR inversely correlated and were significantly associated with hemoglobin concentrations. The consumption of animal source foods (ASF significantly impacts on the interaction between ferritin, sTfR and hemoglobin. Concentrations of RBP were significantly higher in children who had received a vitamin A supplement. The CFI was associated with sTfR and hemoglobin. Lower length and weight were associated with lower ferritin levels and showed an indirect effect on hemoglobin through ferritin.Nutrition programs targeting children under 2 years of age need to focus on the preparation of complementary foods with high nutrient density to sustainably prevent micronutrient deficiency and generally improve nutritional status. Future assessments of the micronutrient status should include identification of hemoglobinopathies and parasitic infections to better understand all causes of anemia in Cambodian infants and young children.German Clinical Trials

  19. Selection of aptamers specific for glycated hemoglobin and total hemoglobin using on-chip SELEX.

    Science.gov (United States)

    Lin, Hsin-I; Wu, Ching-Chu; Yang, Ching-Hsuan; Chang, Ko-Wei; Lee, Gwo-Bin; Shiesh, Shu-Chu

    2015-01-21

    Blood glycated hemoglobin (HbA1c) levels reflecting average glucose concentrations over the past three months are fundamental for the diagnosis, monitoring, and risk assessment of diabetes. It has been hypothesized that aptamers, which are single-stranded DNAs or RNAs that demonstrate high affinity to a large variety of molecules ranging from small drugs, metabolites, or proteins, could be used for the measurement of HbA1c. Aptamers are selected through an in vitro process called systematic evolution of ligands by exponential enrichment (SELEX), and they can be chemically synthesized with high reproducibility at relatively low costs. This study therefore aimed to select HbA1c- and hemoglobin (Hb)-specific single-stranded DNA aptamers using an on-chip SELEX protocol. A microfluidic SELEX chip was developed to continuously and automatically carry out multiple rounds of SELEX to screen specific aptamers for HbA1c and Hb. HbA1c and Hb were first coated onto magnetic beads. Following several rounds of selection and enrichment with a randomized 40-mer DNA library, specific oligonucleotides were selected. The binding specificity and affinity were assessed by competitive and binding assays. Using the developed microfluidic system, the incubation and partitioning times were greatly decreased, and the entire process was shortened dramatically. Both HbA1c- and Hb-specific aptamers selected by the microfluidic system showed high specificity and affinity (dissociation constant, Kd = 7.6 ± 3.0 nM and 7.3 ± 2.2 nM for HbA1c and Hb, respectively). With further refinements in the assay, these aptamers may replace the conventional antibodies for in vitro diagnostics applications in the near future.

  20. Engineering the oxygen sensing regulation results in an enhanced recombinant human hemoglobin production by Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Martinez Ruiz, José Luis; Liu, Lifang; Petranovic, Dina

    2015-01-01

    Efficient production of appropriate oxygen carriers for transfusions (blood substitutes or artificial blood) has been pursued for many decades, and to date several strategies have been used, from synthetic polymers to cell-free hemoglobin carriers. The recent advances in the field of metabolic en...... the transcription factor HAP1, which resulted in an increase of the final recombinant active hemoglobin titer exceeding 7% of the total cellular protein....

  1. The role of nitric oxide and hemoglobin in plant development and morphogenesis

    DEFF Research Database (Denmark)

    Hebelstrup, Kim; Shah, Jay K; Igamberdiev, Abir U

    2013-01-01

    effects on control of plant growth and development, such as shoot and root architecture. All plants are able to express non-symbiotic hemoglobins at low concentration. Their function is generally not related to oxygen transport or storage; instead they effectively oxidize NO to NO3– and thereby control...... the local cellular NO concentration. In this review, we analyze available data on the role of NO and plant hemoglobins in morphogenetic processes in plants. The comparison of the data suggests that hemoglobin gene expression in plants modulates development and morphogenesis of organs, such as roots...... and shoots, through the localized control of NO, and that hemoglobin gene expression should always be considered a modulating factor in processes controlled directly or indirectly by NO in plants....

  2. Evaluation of the i-STAT point-of-care capillary whole blood hematocrit and hemoglobin: Comparison to the Siemens RAPIDLab 1200, Sysmex XE5000, and manual spun hematocrit.

    Science.gov (United States)

    Rudolf, Joseph; Douglass, Joseph; Baron, Jason; Lewandrowski, Kent

    2015-06-15

    Conductivity based point-of-care hematocrit with calculated hemoglobin devices serves an important role in clinical scenarios where time sensitive transfusion decisions are necessary. However, questions about the appropriateness of conductivity based assays in certain patient populations (patients on cardiopulmonary bypass and those receiving high volumes of intravenous fluids or autologous blood transfusions) have been raised. The clinical suitability of POC devices for these applications necessitates that they be accurate and that the results are interchangeable with central laboratory methods. We performed hematocrit and hemoglobin analysis on 225 clinical samples using the i-STAT instrument, a standard reference method for hematocrit (manual spun) and other common methods on both cardiopulmonary bypass and non-cardiopulmonary bypass patients. The i-STAT hematocrit and hemoglobin showed close agreement to comparison methods with minimal bias. Median test results were not clinically or statistically different between those measured on the i-STAT and those measured using the manual spun hematocrit reference method (p=0.4085, Wilcoxon signed rank test) or the Sysmex photometric hemoglobin method (p=0.2728, Wilcoxon signed rank test). The results on the i-STAT were statistically different from those obtained on the Sysmex for hematocrit (phemoglobin (phematocrit and hemoglobin performs well when compared to the hematocrit reference method and other common methods for both hematocrit and hemoglobin. Some differences between non-reference methods may be observed, but these were not considered clinically significant. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Respiratory ammonia output and blood ammonia concentration during incremental exercise

    NARCIS (Netherlands)

    Ament, W; Huizenga, [No Value; Kort, E; van der Mark, TW; Grevink, RG; Verkerke, GJ

    The aim of this study was to investigate whether the increase of ammonia concentration and lactate concentration in blood was accompanied by an increased expiration of ammonia during graded exercise. Eleven healthy subjects performed an incremental cycle ergometer test. Blood ammonia, blood lactate

  4. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  5. Human macrophage hemoglobin-iron metabolism in vitro

    International Nuclear Information System (INIS)

    Custer, G.; Balcerzak, S.; Rinehart, J.

    1982-01-01

    An entirely in vitro technique was employed to characterize hemoglobin-iron metabolism by human macrophages obtained by culture of blood monocytes and pulmonary alveolar macrophages. Macrophages phagocytized about three times as many erythrocytes as monocytes and six times as many erythrocytes as pulmonary alveolar macrophages. The rate of subsequent release of 59 Fe to the extracellular transferrin pool was two- to fourfold greater for macrophages as compared to the other two cell types. The kinetics of 59 Fe-transferrin release were characterized by a relatively rapid early phase (hours 1-4) followed by a slow phase (hours 4-72) for all three cell types. Intracellular movement of iron was characterized by a rapid shift from hemoglobin to ferritin that was complete with the onset of the slow phase of extracellular release. A transient increase in 59 Fe associated with an intracellular protein eluting with transferrin was also observed within 1 hour after phagocytosis. The process of hemoglobin-iron release to extracellular transferrin was inhibited at 4 degrees C but was unaffected by inhibitory of protein synthesis, glycolysis, microtubule function, and microfilament function. These data emphasize the rapidity of macrophage hemoglobin iron metabolism, provide a model for characterization of this process in vitro, and in general confirm data obtained utilizing in vivo animal models

  6. Diagnosis of iron deficiency anemia using density-based fractionation of red blood cells.

    Science.gov (United States)

    Hennek, Jonathan W; Kumar, Ashok A; Wiltschko, Alex B; Patton, Matthew R; Lee, Si Yi Ryan; Brugnara, Carlo; Adams, Ryan P; Whitesides, George M

    2016-10-05

    Iron deficiency anemia (IDA) is a nutritional disorder that impacts over one billion people worldwide; it may cause permanent cognitive impairment in children, fatigue in adults, and suboptimal outcomes in pregnancy. IDA can be diagnosed by detection of red blood cells (RBCs) that are characteristically small (microcytic) and deficient in hemoglobin (hypochromic), typically by examining the results of a complete blood count performed by a hematology analyzer. These instruments are expensive, not portable, and require trained personnel; they are, therefore, unavailable in many low-resource settings. This paper describes a low-cost and rapid method to diagnose IDA using aqueous multiphase systems (AMPS)-thermodynamically stable mixtures of biocompatible polymers and salt that spontaneously form discrete layers having sharp steps in density. AMPS are preloaded into a microhematocrit tube and used with a drop of blood from a fingerstick. After only two minutes in a low-cost centrifuge, the tests (n = 152) were read by eye with a sensitivity of 84% (72-93%) and a specificity of 78% (68-86%), corresponding to an area under the curve (AUC) of 0.89. The AMPS test outperforms diagnosis by hemoglobin alone (AUC = 0.73) and is comparable to methods used in clinics like reticulocyte hemoglobin concentration (AUC = 0.91). Standard machine learning tools were used to analyze images of the resulting tests captured by a standard desktop scanner to 1) slightly improve diagnosis of IDA-sensitivity of 90% (83-96%) and a specificity of 77% (64-87%), and 2) predict several important red blood cell parameters, such as mean corpuscular hemoglobin concentration. These results suggest that the use of AMPS combined with machine learning provides an approach to developing point-of-care hematology.

  7. Relationship between maternal sodium intake and blood lead concentration during pregnancy.

    Science.gov (United States)

    Lee, Yo A; Hwang, Ji-Yun; Kim, Hyesook; Kim, Ki Nam; Ha, Eun-Hee; Park, Hyesook; Ha, Mina; Kim, Yangho; Hong, Yun-Chul; Chang, Namsoo

    2013-03-14

    Pb is released from bone stores during pregnancy, which constitutes a period of increased bone resorption. A high Na intake has been found to be negatively associated with Ca and adversely associated with bone metabolism. It is possible that a high Na intake during pregnancy increases the blood Pb concentration; however, no previous study has reported on the relationship between Na intake and blood Pb concentration. We thus have investigated this relationship between Na intake and blood Pb concentrations, and examined whether this relationship differs with Ca intake in pregnant Korean women. Blood Pb concentrations were analysed in 1090 pregnant women at mid-pregnancy. Dietary intakes during mid-pregnancy were estimated by a 24 h recall method covering the use of dietary supplements. Blood Pb concentrations in whole-blood samples were analysed using graphite furnace atomic absorption spectrophotometry. Multiple regression analysis performed after adjustment for covariates revealed that maternal Na intake was positively associated with blood Pb concentration during pregnancy, but only when Ca intake was below the estimated average requirement for pregnant Korean women (P= 0·001). The findings of the present study suggest that blood Pb concentration during pregnancy could be minimised by dietary recommendations that include decreased Na and increased Ca intakes.

  8. Weight-length relationship, condition factor and blood parameters of farmed Cichla temensis Humboldt, 1821 (Cichlidae in central Amazon

    Directory of Open Access Journals (Sweden)

    Marcos Tavares-Dias

    Full Text Available Farming of native carnivore fish species has drawn attention due to their promising use in aquaculture. Among these species, tucunaré of the genus Cichla stand out, them being of high economical interest for sport fishing and Amazon's industry of ornamental fish. The present study describes the weight-length relationship (WLR, relative condition factor (Kn, red blood cell parameters, thrombocytes and leukocytes count of Cichla temensis Humboldt, 1821, farmed in central Amazon. Fish that underwent food training during fingerling culture received extruded ration containing 45% of crude protein during fattening, and had Kn with values from 0.925-1.199, which indicated good health condition during the culture. The equation obtained from the WLR was W = 0.0073Lt3.1435, indicating an isometric growth, which is the desirable for fish of fish farm. Red blood cell counts, total thrombocyte and leukocyte counts, hematocrit, hemoglobin concentration, mean corpuscular volume (MCV, concentration of mean corpuscular hemoglobin (MCHC, lymphocytes, monocytes and neutrophils had intra-specific variation. A significant (p<0.001 positive correlation of the red blood cells number with the hemoglobin concentration and hematocrit was found. These are the first sets of blood parameters for C. temensis and could be used as reference for comparison in further studies to evaluate the health status of this fish in different environments, because assessment of these parameters may be used as quick tool for diagnosing diseases, stress and malnutrition.

  9. Study of methyl bromide reactivity with human and mouse hemoglobin

    African Journals Online (AJOL)

    A study has been carried out on in-vitro reactivity of human and mouse hemoglobin spectrophotometrically at physiological pH, using different protein to reagent ratios. Hemoglobin side chains were modified with different concentrations of methyl bromide on agro-soil fumigant. To ascertain if the site of alkylation was the ...

  10. Predeposit autologous blood transfusion: Do we require to promote it?

    Directory of Open Access Journals (Sweden)

    Gurjit Singh

    2015-01-01

    Full Text Available Introduction: Safest blood a patient can receive is his own. Quest for safe blood transfusion has remained of prime concern. To meet this aspiration, various forms of autologous blood transfusions can be practiced. It is especially suitable for patients with rare blood groups and religious sects such as Jehovah′s witness autologous transfusion is extremely safe. Cross matching is not required; iso-immunization to a foreign body is excluded. Fear of transfusion transmissible disease can be ignored. Therefore, autologous blood transfusion is required to be revisited. Materials and Methods: This is a prospective study carried out at Padmashree Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune between July 2010 and May 2012. Study comprised of 100 patients divided into two groups, autologous and homologous. Benefits of autologous transfusion were studied. Results: There was no significant change in hematocrit and blood parameters after blood donation. That is mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration (P < 0.001 after blood donation. Only one complication of vasovagal syncope was observed at the time of blood donation. Conclusion: Autologous blood transfusion is safe. Easy alternative to be practiced in elective surgeries, especially in patients with rare blood group or believers of Jehovah′s witness faith. It helps to reduce the shortfall in national blood inventory. Autologous blood donation should be practiced whenever possible.

  11. Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish.

    Science.gov (United States)

    Harrenstien, Lisa A; Tornquist, Susan J; Miller-Morgan, Timothy J; Fodness, Brian G; Clifford, Kevin E

    2005-01-15

    To compare values of blood parameters in rockfish obtained by use of a point-of-care portable blood analyzer with values determined by a veterinary diagnostic laboratory, calculate reference ranges for various blood parameters in black rockfish, and compare values of blood parameters in clinically normal fish with those of fish with clinical abnormalities. Prospective study. 41 captive adult black rockfish (Sebastes melanops) and 4 captive adult blue rockfish (Sebastes mystinus). Rockfish were anesthetized with tricaine methanesulfonate for collection of blood samples. Heparinized blood samples were immediately analyzed with a point-of-care analyzer. Blood sodium, potassium, chloride, urea nitrogen, and glucose concentrations; Hct; pH; partial pressure of carbon dioxide; total carbon dioxide concentration; bicarbonate concentration; base excess; and hemoglobin concentration were determined. A microhematocrit technique was used to determine PCV, and a refractometer was used to estimate total plasma protein concentration. Paired heparinized blood samples were transported to a veterinary diagnostic laboratory for analyses. Data obtained with the point-of-care analyzer were reproducible; however, values for most blood parameters were significantly different from those obtained by the veterinary diagnostic laboratory. Fish with poor body condition had several blood parameter values that were lower than corresponding values in clinically normal fish. Point-of-care blood analyses may prove useful in rockfish. Point-of-care data for a large number of clinically normal fish must be obtained for reference ranges to be calculated, and further assessments of clinically abnormal fish are necessary to determine the relevance of the data.

  12. Effect of a 21-day balneotherapy program on blood cell counts, ponogen levels, and blood biochemical indexes in servicemen in sub-health condition.

    Science.gov (United States)

    Xu, Li; Wu, Lin; Liu, Tingting; Xing, Wenrong; Cao, Xinsheng; Zhang, Shu; Su, Zongyi

    2017-09-01

    [Purpose] The aim of our study was to explore the changes in the blood of servicemen in sub-health conditions during a 21-day balneotherapy program. [Subjects and Methods] For this study, 129 servicemen in sub-health condition were recruited. The subjects were randomly divided into either the balneotherapy group (70) or the control group (59). Subjects in the balneotherapy group received whole-body immersion bath therapy in thermomineral water (30 min daily) for 21 days. Their blood samples were examined 1 day before and after balneotherapy. The parameters studied included mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), white blood cell (WBC), lactic acid (LAC), alanine aminotransferase (ALT), glucose (GLU), and triglycerides (TG) levels. [Results] After 21 days of balneotherapy, MCH levels and MCHC increased significantly and WBC counts increased significantly. LAC levels decreased significantly. ALT, GLU, and TG levels decreased significantly. In the control group, there were no statistical differences before and after tap water baths following the same procedure. [Conclusion] A 21-day balneotherapy program significantly improved blood cell counts and blood biochemical indexes and reduced ponogen levels in servicemen in sub-health condition.

  13. [Hemoglobin variants in Colombian patients referred to discard hemoglobinopathies].

    Science.gov (United States)

    Romero-Sánchez, Consuelo; Gómez Gutiérrez, Alberto; Duarte, Yurani; Amazo, Constanza; Manosalva, Clara; Chila M, Lorena; Casas-Gómez, María Consuelo; Briceño Balcázar, Ignacio

    2015-10-01

    Oxygen transport is altered in hemoglobinopathies. To study the distribution of hemoglobinopathies in Andean subjects without African ancestry. We analyzed blood samples of 1,407 subjects aged 18 to 59 years (58% females), living in the central Andean region of Colombia, referred to discard hemoglobinopathies. The frequency and type of hemoglobinopathy was established by capillary and agarose gel electrophoresis. The frequency of hemoglobinopathies was 34.5% and higher among females. The structural variants found were: AS-heterozygous hemoglobin (8.1%), homozygous SS (3.7%), heterozygous SC (2.2%), AC heterozygotes (0.5%) and heterozygous AE (0.3%). Quantitative variants found were Hb A-Beta thalassemia (13.91%) and Hb H (0.06%), Beta-thalassemia heterozygotes C (0.88%), S-Beta thalassemia heterozygotes (6.07%) and compound heterozygous SC/Beta thalassemia (0.25%), with a persistence of fetal hemoglobin 0. Composite thalassemia was also found in 31%. All techniques showed good correlation and capillary electrophoresis demonstrated a greater detection of hemoglobin variants. The frequency of hemoglobin variants in the analyzed population was high, which is an important public health indicator. The most common hemoglobin variant was HbA/Increased structural Hb A2 and the mos frequent structural hemoglobinopathy was sickle cell trait. Capillary electrophoresis can discern any Hb variants present in the population.

  14. Emergency transfusion of patients with unknown blood type with blood group O Rhesus D positive red blood cell concentrates: a prospective, single-centre, observational study.

    Science.gov (United States)

    Selleng, Kathleen; Jenichen, Gregor; Denker, Kathrin; Selleng, Sixten; Müllejans, Bernd; Greinacher, Andreas

    2017-05-01

    Emergency patients with unknown blood type usually receive O Rhesus D negative (RhD-) red blood cell concentrates until their blood group is determined to prevent RhD+ related adverse transfusion reactions. As 85% of individuals are RhD+, this consumption of O RhD- red blood cell concentrates contributes to shortages of O RhD- red blood cell concentrates, sometimes forcing transfusion of known RhD- patients with RhD+ red blood cell concentrates. Here we report the outcome of this transfusion policy transfusing all emergency patients with unknown blood type with O RhD+ red blood cell concentrates. In this prospective single-centre observational study done between Jan 1, 2001, and Dec 31, 2015, we assessed all consecutive RhD- patients at the University Medicine Greifswald who received RhD+ red blood cell concentrates (emergency patients with unknown blood type; and RhD- patients receiving RhD+ red blood cell concentrates during RhD- red blood cell concentrate shortages). No patients were excluded. The primary endpoint was anti-D allo-immunisation at 2 months follow-up or later. Patients were followed up and tested for immunisation against red blood cell antigens using the direct antiglobulin test and an antibody screen every 3-5 days for 4 weeks or until death, or hospital discharge. Surviving patients were screened for development of anti-D antibodies for up to 12 months (at the predefined timepoints 2, 3, 6, and 12 months) after RhD+ red blood cell transfusion. 437 emergency patients, of whom 85 (20%) were RhD-, received 2836 RhD+ red blood cell concentrates. The overall risk of inducing anti-D antibodies (in all 437 recipients) was 17 (4%, 95% CI 2·44-6·14) of 437 (assuming all patients lost to follow-up developed anti-D allo-immunisation). During this period, 110 known RhD- patients received RhD+ red blood cell concentrates during RhD- red blood cell concentrate shortages. Of these, 29 (26%; 95% CI 19·0-35·3) developed anti-D allo-immunisation (assuming all

  15. Autologous Transfusion of Stored Red Blood Cells Increases Pulmonary Artery Pressure

    Science.gov (United States)

    Pinciroli, Riccardo; Stowell, Christopher P.; Wang, Lin; Yu, Binglan; Fernandez, Bernadette O.; Feelisch, Martin; Mietto, Cristina; Hod, Eldad A.; Chipman, Daniel; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Zapol, Warren M.

    2014-01-01

    Rationale: Transfusion of erythrocytes stored for prolonged periods is associated with increased mortality. Erythrocytes undergo hemolysis during storage and after transfusion. Plasma hemoglobin scavenges endogenous nitric oxide leading to systemic and pulmonary vasoconstriction. Objectives: We hypothesized that transfusion of autologous blood stored for 40 days would increase the pulmonary artery pressure in volunteers with endothelial dysfunction (impaired endothelial production of nitric oxide). We also tested whether breathing nitric oxide before and during transfusion could prevent the increase of pulmonary artery pressure. Methods: Fourteen obese adults with endothelial dysfunction were enrolled in a randomized crossover study of transfusing autologous, leukoreduced blood stored for either 3 or 40 days. Volunteers were transfused with 3-day blood, 40-day blood, and 40-day blood while breathing 80 ppm nitric oxide. Measurements and Main Results: The age of volunteers was 41 ± 4 years (mean ± SEM), and their body mass index was 33.4 ± 1.3 kg/m2. Plasma hemoglobin concentrations increased after transfusion with 40-day and 40-day plus nitric oxide blood but not after transfusing 3-day blood. Mean pulmonary artery pressure, estimated by transthoracic echocardiography, increased after transfusing 40-day blood (18 ± 2 to 23 ± 2 mm Hg; P transfusing 3-day blood (17 ± 2 to 18 ± 2 mm Hg; P = 0.5). Breathing nitric oxide decreased pulmonary artery pressure in volunteers transfused with 40-day blood (17 ± 2 to 12 ± 1 mm Hg; P Transfusion of autologous leukoreduced blood stored for 40 days was associated with increased plasma hemoglobin levels and increased pulmonary artery pressure. Breathing nitric oxide prevents the increase of pulmonary artery pressure produced by transfusing stored blood. Clinical trial registered with www.clinicaltrials.gov (NCT 01529502). PMID:25162920

  16. Placental morphology at different maternal hemoglobin levels: a histopathological study

    International Nuclear Information System (INIS)

    Kiran, N.; Zubair, A.; Malik, T.M.

    2015-01-01

    To evaluate the histopathological parameters of the placenta like weight, infarct and syncytial knots, at different maternal hemoglobin levels, in both qualitative and quantitative manner. Study design: Descriptive study Place and Duration of Study: Army Medical College, National University of Sciences and Technology in collaboration with Department of Obstetrics and Gynecology, Military Hospital, Rawalpindi, Pakistan, from December 2011 to November 2012. Patients and Methods: A total of 75 placentas were included, that were collected from full term mothers at the time of childbirth. Placental weight was taken without umbilical cord and gross placental infarcts were noted. Samples of placental tissue were taken and stained by haematoxylin and eosin (H and E). Microscopic study was done to evaluate placental infarcts and syncytial knots. Results: Mean placental weight at normal and low maternal hemoglobin was 581.67 ± 83.97g and 482.58 ± 104.74g respectively. Gross placental infarcts were found in all cases having low maternal hemoglobin concentration (60% cases). Syncytial knots were found in all placentas but they were considerably more at decreasing levels of maternal hemoglobin (19.79 ± 5.22). Conclusion: The present study showed decrease in placental weight, increase in placental infarcts and syncytial knot hyperplasia at low maternal hemoglobin concentration, displaying adaptive alterations. (author)

  17. Postmortem Quetiapine Reference Concentrations in Brain and Blood

    DEFF Research Database (Denmark)

    Skov, Louise; Johansen, Sys Stybe; Linnet, Kristian

    2015-01-01

    and related to concentrations in postmortem blood. For cases, where quetiapine was unrelated to the cause of death (N 5 36), the 10–90 percentiles for quetiapine concentrations in brain tissue were 0.030 – 1.54 mg/kg (median 0.48 mg/kg, mean 0.79 mg/kg). Corresponding blood 10 –90 percentile values were 0.......007 – 0.39 mg/kg (median 0.15 mg/kg, mean 0.19 mg/kg), giving brain –blood ratio 10 –90 percentiles of 2.31 – 6.54 (median 3.87, mean 4.32). Both correspond well to the limited amount of data found in the literature. For cases where quetiapine was a contributing factor to death (N 5 5), the median value......Brain tissue is a useful alternative to blood in postmortem forensic investigations, but scarcity of information on reference concentrations in brain tissue makes interpretation challenging. Here we present a study of 43 cases where the antipsychotic drug quetiapine was quantified in brain tissue...

  18. Blood gas sample spiking with total parenteral nutrition, lipid emulsion, and concentrated dextrose solutions as a model for predicting sample contamination based on glucose result.

    Science.gov (United States)

    Jara-Aguirre, Jose C; Smeets, Steven W; Wockenfus, Amy M; Karon, Brad S

    2018-05-01

    Evaluate the effects of blood gas sample contamination with total parenteral nutrition (TPN)/lipid emulsion and dextrose 50% (D50) solutions on blood gas and electrolyte measurement; and determine whether glucose concentration can predict blood gas sample contamination with TPN/lipid emulsion or D50. Residual lithium heparin arterial blood gas samples were spiked with TPN/lipid emulsion (0 to 15%) and D50 solutions (0 to 2.5%). Blood gas (pH, pCO2, pO2), electrolytes (Na+, K+ ionized calcium) and hemoglobin were measured with a Radiometer ABL90. Glucose concentration was measured in separated plasma by Roche Cobas c501. Chart review of neonatal blood gas results with glucose >300 mg/dL (>16.65 mmol/L) over a seven month period was performed to determine whether repeat (within 4 h) blood gas results suggested pre-analytical errors in blood gas results. Results were used to determine whether a glucose threshold could predict contamination resulting in blood gas and electrolyte results with greater than laboratory-defined allowable error. Samples spiked with 5% or more TPN/lipid emulsion solution or 1% D50 showed glucose concentration >500 mg/dL (>27.75 mmol/L) and produced blood gas (pH, pO 2 , pCO 2 ) results with greater than laboratory-defined allowable error. TPN/lipid emulsion, but not D50, produced greater than allowable error in electrolyte (Na + ,K + ,Ca ++ ,Hb) results at these concentrations. Based on chart review of 144 neonatal blood gas results with glucose >250 mg/dL received over seven months, four of ten neonatal intensive care unit (NICU) patients with glucose results >500 mg/dL and repeat blood gas results within 4 h had results highly suggestive of pre-analytical error. Only 3 of 36 NICU patients with glucose results 300-500 mg/dL and repeat blood gas results within 4 h had clear pre-analytical errors in blood gas results. Glucose concentration can be used as an indicator of significant blood sample contamination with either TPN

  19. Hematological and morphometric blood value of four cultured species of economically important tropical foodfish

    Directory of Open Access Journals (Sweden)

    Genoefa Amália Dal'Bó

    Full Text Available The use and validation of fish health monitoring tools have become increasingly evident due to aquaculture expansion. This study investigated the hematology and blood morphometrics of Piaractus mesopotamicus, Brycon orbignyanus, Oreochromis niloticus and Rhamdia quelen. The fish were kept for 30 days in 300-liter aquariums, after which they were anesthetized with benzocaine and blood was collected from caudal vessels. In comparison to other species, B. orbignyanus presented the highest hematocrit (Ht, RBC averages and Mean Corpuscular Volume (MCV with a particular range of data. B. orbignyanus presented lower Ht, Hb, RBC averages and values, and Mean Corpuscular Hemoglobin Concentration (MCHC. Oreochromis niloticus presented lower Ht, Hb, RBC averages and values, and Mean Corpuscular Hemoglobin Concentration (MCHC. Rhamdia quelen and O. niloticus presented higher variation of White Blood Cells (WBC, neutrophils (Nf, lymphocytes (Lf, monocytes (Mf and thrombocytes (Trb. Data of large axes (LA, minor axes (MA, surface (SF and volume (VL are in the same variance range. This study has demonstrated that hematological variances can occur between animals of different species as well as of the same species.

  20. Effects of hydroxyurea on blood rheology in sickle cell anemia: A two-years follow-up study.

    Science.gov (United States)

    Lemonne, Nathalie; Möckesch, Berenike; Charlot, Keyne; Garnier, Yohann; Waltz, Xavier; Lamarre, Yann; Antoine-Jonville, Sophie; Etienne-Julan, Maryse; Hardy-Dessources, Marie-Dominique; Romana, Marc; Connes, Philippe

    2017-01-01

    The aim of the present study was to test the effects of hydroxyurea (HU) therapy on clinical, hematological and hemorheological parameters in adult patients with sickle cell anemia (SCA). Hematological and hemorheological parameters were measured in 28 SCA patients before HU therapy (i.e., baseline) and at 6, 12 and 24 months of treatment. RBC deformability was determined by ektacytometry at 30 Pa. RBC aggregation properties were investigated by light-backscatter method. Blood viscosity was measured at 225 s-1 by a cone-plate viscometer. The rates of vaso-occlusive crises and acute chest syndrome were lower at 1 and 2 years of HU therapy compared to baseline. The proportion of patients with leg ulcers tended to decrease after 2 years of treatment. Hemoglobin oxygen saturation improved with HU therapy. HU therapy induced a decrease of platelet and white blood cell counts and a rise in fetal hemoglobin level and mean cell volume. While hemoglobin concentrations increased under HU, blood viscosity remained unchanged all along the study. RBC deformability increased over baseline values at 6 months of HU therapy and continued to rise until the end of the follow-up period. In conclusion, the improvement in RBC deformability probably compensates the increase of hemoglobin on blood viscosity and participates to the improvement of the clinical status of patients.

  1. Blood conservation operations in pediatric cardiac patients: a paradigm shift of blood use.

    Science.gov (United States)

    Karimi, Mohsen; Florentino-Pineda, Ivan; Weatherred, Ted; Qadeer, Ahsan; Rosenberg, Carol Ann; Hudacko, Andrea; Ryu, Duchwan

    2013-03-01

    Red blood cell transfusion is associated with high morbidity in pediatric patients undergoing cardiac operations. The aim of this study was to evaluate the clinical effects and outcomes of blood conservation for our pediatric patients undergoing cardiac operations. We retrospectively analyzed a collected database of 168 pediatric patients who underwent biventricular (BV) and univentricular (UV) cardiac operations from 2006 to 2010. Patients were grouped into no blood conservation (n = 86 [BV = 74, UV = 12]) and blood conservation (n = 82 [BV = 68, UV = 14]) cohorts. There were no statistical differences in age, sex, weight, and preoperative or postoperative hemoglobin levels in the BV groups. Even though the blood conservation group had longer cardiopulmonary bypass (CPB) (p conservation group, there were no statistical differences in age, sex, weight, CPB and cross-clamp times, preoperative and postoperative hemoglobin levels, and red blood cell transfusions despite lower intraoperative hemoglobin levels (p conservation group. Logistic regression analysis demonstrated a significant correlation between intraoperative blood transfusion and increased inotropic score, longer duration on the ventilator, and increased length of hospitalization. Blood conservation in pediatric cardiac operations is associated with fewer ventilator days, lower inotropic scores, and shorter lengths of stay. These findings, in addition to attendant risks and side effects of blood transfusion and the rising cost of safer blood products, justify blood conservation in pediatric cardiac operations. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Blood oxygen saturation determined by transmission spectrophotometry of hemolyzed blood samples

    Science.gov (United States)

    Malik, W. M.

    1967-01-01

    Use of the Lambert-Beer Transmission Law determines blood oxygen saturation of hemolyzed blood samples. This simplified method is based on the difference in optical absorption properties of hemoglobin and oxyhemoglobin.

  3. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  4. Hepcidin and hemoglobin content parameters in the diagnosis of iron deficiency in rheumatoid arthritis patients with anemia

    NARCIS (Netherlands)

    Santen, S. van; Dongen-Lases, E.C. van; Vegt, F. de; Laarakkers, C.M.; Riel, P.L. van; Ede, A.E. van; Swinkels, D.W.

    2011-01-01

    OBJECTIVE: To explore the utility of the novel iron indices hepcidin, reticulocyte hemoglobin content (Ret-Hgb), and erythrocyte (red blood cell) hemoglobin content (RBC-Hgb) for detection of iron deficiency in rheumatoid arthritis (RA) patients with anemia and active inflammation and to compare

  5. Maternal hemoglobin concentration and hematocrit values may affect fetus development by influencing placental angiogenesis.

    Science.gov (United States)

    Stangret, Aleksandra; Wnuk, Anna; Szewczyk, Grzegorz; Pyzlak, Michał; Szukiewicz, Dariusz

    2017-01-01

    Vasculogenesis and angiogenesis are crucial for maintaining proper placental perfusion and optimal fetal development. Among other physical and chemical factors, hypoxia is known to stimulate angiogenic processes. Preplacental type of hypoxia is often associated with maternal anemia and is thought to enhance vascularization within the fetoplacental unit. The goal of this study was to establish the correlation between the local expression of vascular endothelial growth factor (VEGF) and placenta growth factor (PlGF) receptors (flt-1, flk-1) with maternal hemoglobin (Hb) concentration, hematocrit (Ht) values and the infant birthweight. In total, 43 specimens of term placentas obtained from normal course pregnancies delivered at term were included in the study. The expression of flt-1 and flk-1 receptors was analyzed by immunohistochemical staining. Vascular/extravascular tissular index (V/EVTI) was measured by assessing a total vascular area. Nonparametric Mann-Whitney U-test and Spearman's rank correlation were used to compare the various parameters and their differences between the groups. Among the patients with low Hb concentration, nearly 2-fold greater expression of the flt-1 receptor was positively correlated with infants birthweight (p = 0.028). Increased placental vascular density (increased flt-1 expression), during a physiological course of gestation, may be an adaptive response to lowered maternal Hb concentration and Ht values encountered during pregnancy.

  6. Spin Label Studies of the Hemoglobin-Membrane Interaction During Sickle Hemoglobin Polymerization

    International Nuclear Information System (INIS)

    Falcon Dieguez, Jose E.; Rodi, Pablo; Lores Guevara, Manuel A.; Gennaro, Ana Maria

    2009-12-01

    An enhanced hemoglobin-membrane association has been previously documented in Sickle Cell Anemia. However, it is not known how this interaction is modified during the hemoglobin S polymerization process. In this work, we use a model of reconstituted erythrocytes from ghost membranes whose cytoskeleton proteins had been previously labeled with the 4-maleimido Tempo spin label, and that were subsequently resealed with hemoglobin S or A solutions. Using EPR spectroscopy, we studied the time dependence of the spectral W/S parameter, indicative of the conformational state of cytoskeleton proteins (mainly spectrin) under spontaneous deoxygenation, with the aim of detecting the eventual effects due to hemoglobin S polymerization. The differences observed in the temporal behaviour of W/S in erythrocytes reconstituted with both hemoglobins were considered as experimental evidence of an increment in hemoglobin S-membrane interaction, as a result of the polymerization process of hemoglobin S under spontaneous deoxygenation. (author)

  7. Utility of noninvasive transcutaneous measurement of postoperative hemoglobin in total joint arthroplasty patients.

    Science.gov (United States)

    Stoesz, Michael; Wood, Kristin; Clark, Wesley; Kwon, Young-Min; Freiberg, Andrew A

    2014-11-01

    This study prospectively evaluated the clinical utility of a noninvasive transcutaneous device for postoperative hemoglobin measurement in 100 total hip and knee arthroplasty patients. A protocol to measure hemoglobin noninvasively, prior to venipuncture, successfully avoided venipuncture in 73% of patients. In the remaining 27 patients, there were a total of 48 venipunctures performed during the postoperative hospitalization period due to reasons including transcutaneous hemoglobin measurement less than or equal to 9 g/dL (19), inability to obtain a transcutaneous hemoglobin measurement (8), clinical signs of anemia (3), and noncompliance with the study protocol (18). Such screening protocols may provide a convenient and cost-effective alternative to routine venipuncture for identifying patients at risk for blood transfusion after elective joint arthroplasty. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Science.gov (United States)

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  9. Carbon monoxide concentration in donated blood: relation to cigarette smoking and other sources.

    Science.gov (United States)

    Aberg, Anna-Maja; Sojka, Birgitta Nilsson; Winsö, Ola; Abrahamsson, Pernilla; Johansson, Göran; Larsson, Jan Erik

    2009-02-01

    Carbon monoxide (CO) is normally present in the human body due to endogenous production of CO. CO can also be inhaled by exposure to external sources such as cigarette smoke, car exhaust, and fire. The purpose of this study was to investigate CO concentrations in blood from 410 blood donors at the blood center in Umeå, Sweden. To further evaluate the effects of cigarette smoking on CO concentrations, the elimination time for CO was examined in six volunteer smokers after a smoked cigarette. Blood samples from whole blood donors were obtained during the blood center's routine operation. In connection with blood donations, demographic and behavioral data were collected from the donors. The CO concentration was determined using gas chromatography. The majority of blood donors had approximately the same CO concentration (mean, 84.5 micromol/L). In 6 percent of the samples, the concentrations were higher than 130 micromol per L. The highest CO concentration was 561 micromol per L. The main source for these high CO concentrations appeared to be cigarette smoking. In the volunteer smokers, the elimination time after a smoked cigarette varied significantly, with elimination half-lives from 4.7 to 8.4 hours. These results show that blood bank red blood cell bags may have CO concentrations above the physiologic level. The time interval between cigarette smoking and blood donation seems to be a particularly important factor for elevated CO concentrations.

  10. Changes of hemoglobin and hematocrit in elderly patients receiving lower joint arthroplasty without allogeneic blood transfusion.

    Science.gov (United States)

    Zhou, Qi; Zhou, Yiqin; Wu, Haishan; Wu, Yuli; Qian, Qirong; Zhao, Hui; Zhu, Yunli; Fu, Peiliang

    2015-01-05

    It has rarely been reported about the changes of hemoglobin (Hb) and hematocrit (Hct) in elderly patients receiving total knee arthroplasty (TKA) or total hip arthroplasty (THA). This study aimed to evaluate the changes of Hb and Hct after TKA or THA in elderly patients, and analyze its relationship with sex and type of arthroplasty. This is a prospective cohort study, including 107 patients receiving TKA or THA without allogeneic blood transfusion. There were 54 males and 53 females, with a mean age of 69.42 years. Levels of Hb and Hct were examined preoperatively and during the 6 months follow-up after operation. Levels of Hb and Hct decreased postoperatively and reached their minimum points on postoperative day 4. Thereafter, Hb and Hct recovered to their preoperative levels within 6-12 weeks. No significant differences in the levels of Hb and Hct were noticed between different sexes. THA patients showed significantly greater drop in Hb and Hct than TKA patients in the first 4 days postoperatively (P < 0.05). Levels of Hb and Hct decreased during the first 4 days after arthroplasty and gradually returned to their normal levels within 6-12 weeks postoperatively. THA may be associated with higher postoperative blood loss than TKA.

  11. Evaluation of a blood conservation strategy in the intensive care unit: a prospective, randomised study.

    LENUS (Irish Health Repository)

    Mahdy, Saad

    2012-02-01

    OBJECTIVE AND METHODS: Anemia is a common problem in the ICU population. Most patients are anemic at admission, their hemoglobin concentrations declining further thereafter. The aim of the present study was to evaluate the effect of a combination strategy, involving closed arterial blood gas sampling and the use of pediatric vials for phlebotomy (Group A), on the sampling-induced blood loss and the rate of decline in hemoglobin in adult ICU patients. Combination (Group A) was compared to the current standard technique of arterial line sampling and adult vial phlebotomy (Group B) in a prospective, randomised, ethically-approved trial for the first 72 hours of their ICU stay. Peri-operative, oncology, coagulopathic and uremic patients were excluded. All other ICU patients with arterial cannulae and predicted to stay beyond 3 days, were enrolled. RESULTS: 39 patients entered the study, 20 in Group A, and 19 in Group B. Data collection was complete for all. There was a statistically significant difference in sampling-induced blood loss between the groups over the first 72 hours of treatment (mean +\\/- standard deviation: 15.16 +\\/- 5.3 ml Group A vs 45.11 +\\/- 14 ml Group B, p<0.001). There was a smaller decline in mean hemoglobin level, which was not statistically significant (0.79 +\\/- 0.6 g\\/dL vs 1.30 +\\/- 1.13, p = 0.09). CONCLUSIONS: Overall, this strategy reduced measurable blood losses from phlebotomy. In larger trials it might also preserve hemoglobin levels.

  12. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    Science.gov (United States)

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  13. Effects of hydroxyurea treatment for patients with hemoglobin SC disease.

    Science.gov (United States)

    Luchtman-Jones, Lori; Pressel, Sara; Hilliard, Lee; Brown, R Clark; Smith, Mary G; Thompson, Alexis A; Lee, Margaret T; Rothman, Jennifer; Rogers, Zora R; Owen, William; Imran, Hamayun; Thornburg, Courtney; Kwiatkowski, Janet L; Aygun, Banu; Nelson, Stephen; Roberts, Carla; Gauger, Cynthia; Piccone, Connie; Kalfa, Theodosia; Alvarez, Ofelia; Hassell, Kathryn; Davis, Barry R; Ware, Russell E

    2016-02-01

    Although hemoglobin SC (HbSC) disease is usually considered less severe than sickle cell anemia (SCA), which includes HbSS and HbS/β(0) -thalassemia genotypes, many patients with HbSC experience severe disease complications, including vaso-occlusive pain, acute chest syndrome, avascular necrosis, retinopathy, and poor quality of life. Fully 20 years after the clinical and laboratory efficacy of hydroxyurea was proven in adult SCA patients, the safety and utility of hydroxyurea treatment for HbSC patients remain unclear. Recent NHLBI evidence-based guidelines highlight this as a critical knowledge gap, noting HbSC accounts for ∼30% of sickle cell patients within the United States. To date, only 5 publications have reported short-term, incomplete, or conflicting laboratory and clinical outcomes of hydroxyurea treatment in a total of 71 adults and children with HbSC. We now report on a cohort of 133 adult and pediatric HbSC patients who received hydroxyurea, typically for recurrent vaso-occlusive pain. Hydroxyurea treatment was associated with a stable hemoglobin concentration; increased fetal hemoglobin (HbF) and mean corpuscular volume (MCV); and reduced white blood cell count (WBC), absolute neutrophil count (ANC), and absolute reticulocyte count (ARC). Reversible cytopenias occurred in 22% of patients, primarily neutropenia and thrombocytopenia. Painful events were reduced with hydroxyurea, more in patients >15 years old. These multicenter data support the safety and potentially salutary effects of hydroxyurea treatment for HbSC disease; however, a multicenter, placebo-controlled, Phase 3 clinical trial is needed to determine if hydroxyurea therapy has efficacy for patients with HbSC disease. © 2015 Wiley Periodicals, Inc.

  14. A common signaling pathway is activated in erythroid cells expressing high levels of fetal hemoglobin: a potential role for cAMP-elevating agents in β-globin disorders

    Directory of Open Access Journals (Sweden)

    Ikuta T

    2013-12-01

    Full Text Available Tohru Ikuta,1 Yuichi Kuroyanagi,1 Nadine Odo,1 Siyang Liu21Department of Anesthesiology and Perioperative Medicine, 2Department of Physiology, Medical College of Georgia, Georgia Regents University, Augusta, GA, USABackground: Although erythroid cells prepared from fetal liver, cord blood, or blood from β-thalassemia patients are known to express fetal hemoglobin at high levels, the underlying mechanisms remain elusive. We previously showed that cyclic nucleotides such as cAMP and cGMP induce fetal hemoglobin expression in primary erythroid cells. Here we report that cAMP signaling contributes to high-level fetal hemoglobin expression in erythroid cells prepared from cord blood and β-thalassemia.Methods: The status of the cAMP signaling pathway was investigated using primary erythroid cells prepared from cord blood and the mononuclear cells of patients with β-thalassemia; erythroid cells from adult bone marrow mononuclear cells served as the control.Results: We found that intracellular cAMP levels were higher in erythroid cells from cord blood and β-thalassemia than from adult bone marrow. Protein kinase A activity levels and cAMP-response element binding protein phosphorylation were higher in erythroid cells from cord blood or β-thalassemia than in adult bone marrow progenitors. Mitogen-activated protein kinase pathways, which play a role in fetal hemoglobin expression, were not consistently activated in cord blood or β-thalassemia erythroid cells. When cAMP signaling was activated in adult erythroid cells, fetal hemoglobin was induced at high levels and associated with reduced expression of BCL11A, a silencer of the β-globin gene.Conclusion: These results suggest that activated cAMP signaling may be a common mechanism among erythroid cells with high fetal hemoglobin levels, in part because of downregulation of BCL11A. Activation of the cAMP signaling pathway with cAMP-elevating agents may prove to be an important signaling mechanism to

  15. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  16. Hemoglobin

    Science.gov (United States)

    1993-03-08

    affinity, which is less at low levels of hemoglobin saturation, increases markedly as fractional saturation increases. Thus, high affinity for 02 at... diphosphoglycerate (2,3-DPG), and carbon dioxide (Co 2). Since they are linked to 02 binding, they are called oxygen-linked effectors. The oxygen...hemoglobin molecule because of the negative charge of the ions. 2,3- Diphosphoglycerate is a molecule formed during the breakdown of sugar in normal human

  17. Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion. Nonlinear decay of adult red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Gemert, Martin J C van; Wijngaard, Jeroen P H M van den [Laser Centre and Department of Obstetrics, Academic Medical Centre, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Pasman, Suzanne A; Vandenbussche, Frank P H A [Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden (Netherlands); Lopriore, Enrico [Division of Neonatology, Department of Pediatrics, Leiden University Medical Centre, Leiden (Netherlands)], E-mail: m.j.vangemert@amc.uva.nl

    2008-07-07

    Recently, we derived equations relating the flow of adult red blood cells through a placental arterio-venous anastomosis with intra-uterine and post-natal measured adult hemoglobin concentrations. In this letter, we re-derived the equations, now including a more realistic nonlinear decay of adult red blood cells, and re-evaluated the measurement accuracy of the arterio-venous flow and the lifetime of the red blood cells. (letter to the editor)

  18. Predictors of blood trihalomethane concentrations in NHANES 1999-2006.

    Science.gov (United States)

    Riederer, Anne M; Dhingra, Radhika; Blount, Benjamin C; Steenland, Kyle

    2014-07-01

    Trihalomethanes (THMs) are water disinfection by-products that have been associated with bladder cancer and adverse birth outcomes. Four THMs (bromoform, chloroform, bromodichloromethane, dibromochloromethane) were measured in blood and tap water of U.S. adults in the National Health and Nutrition Examination Survey (NHANES) 1999-2006. THMs are metabolized to potentially toxic/mutagenic intermediates by cytochrome p450 (CYP) 2D6 and CYP2E1 enzymes. We conducted exploratory analyses of blood THMs, including factors affecting CYP2D6 and CYP2E1 activity. We used weighted multivariable regressions to evaluate associations between blood THMs and water concentrations, survey year, and other factors potentially affecting THM exposure or metabolism (e.g., prescription medications, cruciferous vegetables, diabetes, fasting, pregnancy, swimming). From 1999 to 2006, geometric mean blood and water THM levels dropped in parallel, with decreases of 32%-76% in blood and 38%-52% in water, likely resulting, in part, from the lowering of the total THM drinking water standard in 2002-2004. The strongest predictors of blood THM levels were survey year and water concentration (n = 4,232 total THM; n = 4,080 bromoform; n = 4,582 chloroform; n = 4,374 bromodichloromethane; n = 4,464 dibromochloromethane). We detected statistically significant inverse associations with diabetes and eating cruciferous vegetables in all but the bromoform model. Medications did not consistently predict blood levels. Afternoon/evening blood samples had lower THM concentrations than morning samples. In a subsample (n = 230), air chloroform better predicted blood chloroform than water chloroform, suggesting showering/bathing was a more important source than drinking. We identified several factors associated with blood THMs that may affect their metabolism. The potential health implications require further study.

  19. Role of Reversible Histidine Coordination in Hydroxylamine Reduction by Plant Hemoglobins (Phytoglobins).

    Science.gov (United States)

    Athwal, Navjot Singh; Alagurajan, Jagannathan; Andreotti, Amy H; Hargrove, Mark S

    2016-10-18

    Reduction of hydroxylamine to ammonium by phytoglobin, a plant hexacoordinate hemoglobin, is much faster than that of other hexacoordinate hemoglobins or pentacoordinate hemoglobins such as myoglobin, leghemoglobin, and red blood cell hemoglobin. The reason for differences in reactivity is not known but could be intermolecular electron transfer between protein molecules in support of the required two-electron reduction, hydroxylamine binding, or active site architecture favoring the reaction. Experiments were conducted with phytoglobins from rice, tomato, and soybean along with human neuroglobin and soybean leghemoglobin that reveal hydroxylamine binding as the rate-limiting step. For hexacoordinate hemoglobins, binding is limited by the dissociation rate constant for the distal histidine, while leghemoglobin is limited by an intrinsically low affinity for hydroxylamine. When the distal histidine is removed from rice phytoglobin, a hydroxylamine-bound intermediate is formed and the reaction rate is diminished, indicating that the distal histidine imidazole side chain is critical for the reaction, albeit not for electron transfer but rather for direct interaction with the substrate. Together, these results demonstrate that phytoglobins are superior at hydroxylamine reduction because they have distal histidine coordination affinity constants near 1, and facile rate constants for binding and dissociation of the histidine side chain. Hexacoordinate hemoglobins such as neuroglobin are limited by tighter histidine coordination that blocks hydroxylamine binding, and pentacoordinate hemoglobins have intrinsically lower hydroxylamine affinities.

  20. Specific features of red blood cell morphology in hemolytic disease neonates undergoing intrauterine intravascular blood transfusion

    Directory of Open Access Journals (Sweden)

    A. V. Ivanova

    2016-01-01

    Full Text Available The paper presents data on the characteristics of red blood cell morphology in infants who have undergone intrauterine intravascular blood transfusion for hemolytic disease of the fetus. The infants are shown to have a reduction in the mean volume of red blood cells and in their mean level of hemoglobin, a decrease in the fraction of fetal hemoglobin and an increase in oxygen tension at half saturation. The above morphological characteristics of red blood cells remain decreased during the neonatal period after exchange transfusion or others, as clinically indicated, which seems to suggest that the compensatory-adaptive mechanisms to regulate hematopoiesis are exhausted and a donor’s red blood cells continue to be predominant.

  1. Accuracy of Blood Loss Measurement during Cesarean Delivery

    OpenAIRE

    Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.

    2017-01-01

    Objective?This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design?In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood...

  2. [Importance of binding of 2,3-diphosphoglycerate and ATP to hemoglobin for erythrocyte glycolysis: activation by 2,3-diphosphoglycerate of hexokinase at intracellular conditions].

    Science.gov (United States)

    Geier, T; Glende, M; Reich, J G

    1978-01-01

    In a theoretical study the influence of hemoglobin and Mg-ions as binding partners of red cell 2,3-diphosphoglycerate and ATP was investigated. Free hemoglobin may be an efficient competitor of Mg2+ for the ligand ATP. At conditions which favour hemoglobin as binding partner (i.e. desoxygenation, low medium pH and incubation temperature, as in blood preservation) up to 95% of the whole cellular ATP (ca. 2mM in cell water) may be bound to hemoglobin (ca. 7 mM). This binding is largely prevented in the presence of physiological amounts of diphosphoglycerate (ca. 7 mM) which is in excess and has a higher binding affinity to hemoglobin. Therefore, diphosphoglycerate keeps ATP (MgATP) in cell water solution at conditions in which Hb would trop it in the presence of Mg2+ (ca. 3mM). It can be calculated that, by lack of free MgATP, the activity of hexokinase within the cell drops by a factor of greater than 10 when diphosphoglycerate is metabolized. This indirect activation by diphosphoglycerate of hexokinase is operative at free concentrations of DPG far below those which exert the well known excess inhibitory effect on hexokinase and phosphofructokinase. In a model study, the activation by diphosphoglycerate of the initial two-kinase stage was introduced into a simplified kinetic model of glycolysis. A pronounced hysteresis loop of the stationary concentrations of ATP and diphosphoglycerate was produced indicating the existence of several stationary states, one with high ATP and high diphosphoglycerate, the other one with low values. It is demonstrated that diphosphoglycerate, being a protector of glycolysis at physiological concentrations, triggers an autocatalytic breakdown of the energy state when permitted to drop to low values.

  3. Effects of blood transfusion on exercise capacity in thalassemia major patients.

    Directory of Open Access Journals (Sweden)

    Daniela Benedetto

    Full Text Available Anemia has an important role in exercise performance. However, the direct link between rapid changes of hemoglobin and exercise performance is still unknown.To find out more on this topic, we studied 18 beta-thalassemia major patients free of relevant cardiac dysfunction (age 33.5±7.2 years,males = 10. Patients performed a maximal cardiopulmolmonary exercise test (cycloergometer, personalized ramp protocol, breath-by-breath measurements of expired gases before and the day after blood transfusion (500 cc of red cell concentrates. After blood transfusion, hemoglobin increased from 10.5±0.8 g/dL to 12.1±1.2 (p<0.001, peak VO2 from 1408 to 1546mL/min (p<0.05, and VO2 at anaerobic threshold from 965 to 1024mL/min (p<0.05. No major changes were observed as regards heart and respiratory rates either at peak exercise or at anaerobic threshold. Similarly, no relevant changes were observed in ventilation efficiency, as evaluated by the ventilation vs. carbon dioxide production relationship, or in O2 delivery to the periphery as analyzed by the VO2 vs. workload relationship. The relationship between hemoglobin and VO2 changes showed, for each g/dL of hemoglobin increase, a VO2 increase = 82.5 mL/min and 35 mL/min, at peak exercise and at anaerobic threshold, respectively. In beta-thalassemia major patients, an acute albeit partial anemia correction by blood transfusion determinates a relevant increase of exercise performance, observed both at peak exercise and at anaerobic threshold.

  4. Inhibitory potential of pure isoflavonoids, red clover, and alfalfa extracts on hemoglobin glycosylation

    Directory of Open Access Journals (Sweden)

    Mohsen Hosseini

    2015-03-01

    Full Text Available BACKGROUND: Non-enzymatic glycosylation of hemoglobin is complications of diabetes. Antioxidant system imbalance can result in the emergence of free radicals’ destructive effects in the long-term. Red clover (Trifolium pratense L. and alfalfa (Medicago sativa L. contain isoflavonoids and have antioxidant activity. This experimental study evaluated the inhibitory activity of pure isoflavonoids (daidzein and genistein, red clover and alfalfa extracts on hemoglobin glycosylation. METHODS: This study was performed in Iran. Stock solution of hydroalcoholic extracts of red clover and alfalfa in concentrations of 1 and 10 g/100 ml and stock solution of daidzein and genistein in concentrations of 250 ng, 500 ng, 25 µg and 250 µg/100 ml were prepared as case groups. Control group was without hydroalcoholic extracts of plants and pure isoflavonoids. All experiments were performed in triplicate. Hemoglobin was prepared and antioxidant activities were investigated to estimate degree of nonenzymatic hemoglobin glycosylation. RESULTS: There was no significantly difference between used extracts (extract of red clover and alfalfa and control of the hemoglobin glycosylation but using daidzein (P = 0.046, 0.029 and 0.021, respectively and genistein (P = 0.034, 0.036 and 0.028 significantly inhibited (P < 0.050 this reaction in 25 µg/100 ml, 250 and 500 ng/100 ml concentrations when compared to control. in 25 µg/100 ml, 250 ng and 500 ng/100 ml concentrations percentage of inhibition were 32, 80 and 74.5% respectively with used of daidzein and were 21, 83 and 76% respectively with consumption of genistein. CONCLUSION: According to decrease of glycation of hemoglobin with isoflavonoids, two used plant in this study containing isoflavonoid may be useful on diabetes.   

  5. PERBEDAAN KADAR HEMOGLOBIN METODE SIANMETHEMOGLOBIN DENGAN DAN TANPA SENTRIFUGASI PADA SAMPEL LEUKOSITOSIS

    Directory of Open Access Journals (Sweden)

    wahdah norsiah

    2015-12-01

    Full Text Available Abstract: Examination of hemoglobin levels influenced leukocytosis sianmethemoglobin method that causes increased absorbance measurements of hemoglobin levels increased significantly and the false blood sample that has been diluted with a solution Drabkins in centrifugation at 3000 rpm for 10 minutes and then the absorbance of the supernatant was measured with a photometer at λ 546 nm. This study aimed to analyze the differences in hemoglobin level examination siamethemoglobin method with and without centrifugation at sample leukocytosis. This type of research is observational research laboratory. The study design was cross-sectional study. Samples were taken from the remaining blood samples of patients who have been examined leukositnya number more than 20,000 / uL with Hematology Analyzer (CEL-DYN Ruby February-April 2014, and were divided into 4 groups based on criteria that group 1. leukocyte count of 20,000 / uL-29 999 / mL, group II. 30,000 / uL-39 999 / uL, the group III. 40,000 / uL-49,999 / uL, the group IV. More than 50,000 / uL. The number of samples taken were 20 samples of each group, a total sample of 80 samples. The analysis showed no significant difference in hemoglobin levels siamethemoglobin method with and without centrifugation at sample leukocytosis with a value of p = 0.000 less than 0.05 α. Leukocytosis Turbidity affects the difference in hemoglobin levels with and without centrifugation, the higher the number the greater the difference in leukocyte levels of hemoglobin, hemoglobin level examination results of the study based on the criteria of the number of leukocytes obtained by the difference in hemoglobin levels with and without centrifugation in group I. 0.22 ± 0.07 g / dL, group II 0.40 ± 0.22 g / dL, a group III. 0.44 ± 0.14 g / dL, Group IV. 0.85 ± 0.41 g / dL. The level of hemoglobin in the sample sianmethemoglobin method leukocytosis with more than 20,000 / uL need a centrifuge so that appropriate

  6. ATP-induced temperature independence of hemoglobin-O2 affinity in heterothermic billfish

    DEFF Research Database (Denmark)

    Weber, Roy E.; Campbell, Kevin L.; Fago, Angela

    2010-01-01

    heterotherms, where it may hamper unloading (e.g. in cold extremities of arctic mammals) or increase the diffusive arterio-venous short-circuiting of O2 (e.g. in counter-current heat exchangers of warm swimming muscles of tuna). We hypothesized analogous blood specializations in heterothermic billfish, whose......The inverse relationship between temperature and hemoglobin-O2 affinity resulting from the exothermic nature of heme oxygenation favors O2 unloading from blood to warm, metabolically active tissues. However, this temperature sensitivity is maladaptive, and commonly countered in regional...... to allosterically modulating hemoglobin-O2 affinity, ATP diminishes its temperature sensitivity, reducing deleterious arterio-venous short-circuiting of oxygen in the cranial billfish heat exchangers. The mechanism underlying this reduction in oxygenation enthalpy differs fundamentally from that in tuna, supporting...

  7. Development of Liposome Encapsulated Hemoglobin (LEH) and Studies of Hemorrhagic Shock by Use of Imaging Studies with Oxygen-15 and Other Radiotracers

    National Research Council Canada - National Science Library

    Phillips, William T; Goins, Beth; Awasthi, Vibhudutta

    2004-01-01

    .... Encapsulating hemoglobin inside a protective lipid membrane, which mimics a red blood cell, has the advantages of decreasing the toxicity of the free hemoglobin, increasing its circulation time...

  8. Noninvasive measurement of postocclusive parameters in human forearm blood by near infrared spectroscopy

    Science.gov (United States)

    Rao, K. Prahlad; Radhakrishnan, S.; Reddy, M. Ramasubba

    2005-04-01

    Near infrared (NIR) light in the wavelength range from 700 to 900 nm can pass through skin, bone and other tissues relatively easily. As a result, NIR techniques allow a noninvasive assessment of hemoglobin saturation for a wide range of applications, such as in the study of muscle metabolism, the diagnosis of vascular disorders, brain imaging, and breast cancer detection. Near infrared Spectroscopy (NIRS) is an effective tool to measure the hemoglobin concentration in the tissues, which can discriminate optically the oxy- and deoxy- hemoglobin species because of their different near-infrared absorption spectra. We have developed an NIRS probe consisting of a laser diode of 830 nm wavelength and a PIN photodiode in reflectance mode. We have selected a set of healthy volunteers (mean age 30, range 26-40 years) for the study. The probe is placed on forearm of each subject and the backscattered light intensity is measured by occluding the blood flow at 210, 110 and 85 mmHg pressures. Recovery time, peak time and time after 50% release of the cuff pressure are determined from the optical densities during the post occlusive state of forearm. These parameters are useful for determining the transient increase in blood flow after the release of blood occlusion. Clinically, the functional aspects of blood flow in the limbs could be evaluated noninvasively by NIRS.

  9. Patterns of glycemic control using glycosylated hemoglobin in diabetics.

    Science.gov (United States)

    Kahlon, Arunpreet Singh; Pathak, Rambha

    2011-07-01

    Till now estimation of blood glucose is the highly effective method for diagnosing diabetes mellitus but it provides a short-term picture of control. More evidence is required to prove that plasma glucose and glycosylated hemoglobin levels together gives a better estimate of glycemic control and compliance with treatment. Indian diabetes risk score (IDRS) is a simplified screening tool for identifying undiagnosed diabetic subjects, requires minimum time, and effort and can help to considerably reduce the costs of screening. To study patterns of glycemic control using glycosylated hemoglobin in diabetic patients. To find out correlation between levels of plasma glucose and glycosylated hemoglobin in diabetics and to calculate IDRS of the study population. A cross sectional study was conducted among 300 known diabetic patients attending outpatient department of a rural medical college in Haryana, India. Following standard procedures and protocols FPG and glycosylated hemoglobin were measured to find out a pattern of glycemic control in them after taking their written and informed consent. A correlation between the levels of glycosylated hemoglobin and fasting blood glucose was also calculated. These patients were made to fill a performa and their demographic and clinical risk factors were noted and based on this, their IDRS was calculated. This was done to validate the IDRS in Indian rural population. Fifty-two percent of the population had fasting plasma glucose level between 125-150 mg/dl, 21% had this level between 151-175 mg/dl. Thirteen percent of the study subjects had HbA1C between 6.5-7.5, more than half (57.3%) had this value between 7.5-8.5, 12% and 18% had values between 8.5-9.5 and 9.5-10.5, respectively. Twelve percent of the participants had HbA1C level higher than 10.5. Correlation of fasting plasma glucose level and HbA1C was also studied and found that correlation coefficient came out to be .311. This correlation was found to be statistically

  10. Immediate response of the hemoglobin system of the goldfish, Carassius auratu, to temperature change

    Energy Technology Data Exchange (ETDEWEB)

    Houston, A.H.; Rupert, R.

    1976-10-01

    Goldfish acclimated to 3 and 23/sup 0/C were characterized by two- and three-component hemoglobin systems, respectively. After acclimation to a diurnally cycling temperature regime (approximately 3 to approximately 23/sup 0/C), specimens sampled at approximately 23/sup 0/C and approximately 3/sup 0/C were identical in terms of hemoglobin system complexity with those held at equivalent constant temperatures. Abrupt transfer of fish acclimated at constant 23/sup 0/C to 3/sup 0/C, and vice versa, lead to appearance or disappearance of the minor component, G. l, within 3 h. In vitro cooling and warming of whole blood and hemolyzate samples indicated that hemoglobin system modification occurred under cell-free as well as cell-intact conditions. These observations suggest that previously observed quantitative variations in the hemoglobin systems of thermally acclimated teleosts may represent, in part at least, altered aggregation of preexisting subunits rather than de novo hemoglobin synthesis and raise the possibility that teleostean hemoglobin systems may possess a capacity for rapid, adaptative reorganization after environmental temperature variation.

  11. Interplay between up-regulation of cytochrome-c-oxidase and hemoglobin oxygenation induced by near-infrared laser

    Science.gov (United States)

    Wang, Xinlong; Tian, Fenghua; Soni, Sagar S.; Gonzalez-Lima, F.; Liu, Hanli

    2016-08-01

    Photobiomodulation, also known as low-level laser/light therapy (LLLT), refers to the use of red-to-near-infrared light to stimulate cellular functions for physiological or clinical benefits. The mechanism of LLLT is assumed to rely on photon absorption by cytochrome c oxidase (CCO), the terminal enzyme in the mitochondrial respiratory chain that catalyzes the reduction of oxygen for energy metabolism. In this study, we used broadband near-infrared spectroscopy (NIRS) to measure the LLLT-induced changes in CCO and hemoglobin concentrations in human forearms in vivo. Eleven healthy participants were administered with 1064-nm laser and placebo treatments on their right forearms. The spectroscopic data were analyzed and fitted with wavelength-dependent, modified Beer-Lambert Law. We found that LLLT induced significant increases of CCO concentration (Δ[CCO]) and oxygenated hemoglobin concentration (Δ[HbO]) on the treated site as the laser energy dose accumulated over time. A strong linear interplay between Δ[CCO] and Δ[HbO] was observed for the first time during LLLT, indicating a hemodynamic response of oxygen supply and blood volume closely coupled to the up-regulation of CCO induced by photobiomodulation. These results demonstrate the tremendous potential of broadband NIRS as a non-invasive, in vivo means to study mechanisms of photobiomodulation and perform treatment evaluations of LLLT.

  12. Effect of some high consumption spices on hemoglobin glycation.

    Science.gov (United States)

    Naderi, G H; Dinani, Narges J; Asgary, S; Taher, M; Nikkhoo, N; Boshtam, M

    2014-01-01

    Formation of glycation products is major factor responsible in complications of diabetes. Worldwide trend is toward the use of natural additives in reducing the complications of diseases. Therefore, there is a growing interest in natural antiglycation found in plants. Herbs and spices are one of the most important targets to search for natural antiglycation from the point of view of safety. This study investigated the ability of some of the spices to inhibit glycation process in a hemoglobin/glucose model system and compared their potency with each other. For this subject the best concentration and time to incubate glucose with hemoglobin was investigated. Then the glycosylation degree of hemoglobin in the presence of extracts by the three concentrations 0.25, 0.5 and 1 μg/ml was measured colorimetrically at 520 nm. Results represent that some of extracts such as wild caraway, turmeric, cardamom and black pepper have inhibitory effects on hemoglobin glycation. But some of the extracts such as anise and saffron have not only inhibitory effects but also aggravated this event and have proglycation properties. In accordance with the results obtained we can conclude that wild caraway, turmeric, cardamom and black pepper especially wild caraway extracts are potent antiglycation agents, which can be of great value in the preventive glycation-associated complications in diabetes.

  13. Cancer and blood concentrations of the comutagen harmane in essential tremor.

    Science.gov (United States)

    Louis, Elan D; Pellegrino, Kathryn M; Factor-Litvak, Pam; Rios, Eileen; Jiang, Wendy; Henchcliffe, Claire; Zheng, Wei

    2008-09-15

    Blood concentrations of harmane, a tremor-producing neurotoxin, are elevated in essential tremor (ET). Harmane is also a comutagen. Using a case-control design, we compared the prevalence of cancer in ET cases vs. controls, and determined whether blood harmane concentrations are elevated among ET cases with cancer. 66/267 (24.7%) ET cases vs. 55/331 (16.6%) controls had cancer (adjusted OR 1.52, 95% CI 1.01-2.30, P = 0.04). Among specific cancer types, colon cancer was more prevalent in ET cases than controls (2.6% vs. 0.6%, P = 0.04). Log blood harmane concentration was higher in ET cases vs. controls (P = 0.02) and in participants with vs. without cancer (P = 0.02). Log blood harmane concentration was highest in ET cases with cancer when compared with other groups (P = 0.009). These links between cancer and ET and between high blood harmane and cancer in ET deserve further study. (c) 2007 Movement Disorder Society.

  14. Do blood tests cause anemia in hospitalized patients? The effect of diagnostic phlebotomy on hemoglobin and hematocrit levels.

    Science.gov (United States)

    Thavendiranathan, Paaladinesh; Bagai, Akshay; Ebidia, Albert; Detsky, Allan S; Choudhry, Niteesh K

    2005-06-01

    To determine whether phlebotomy contributes to changes in hemoglobin and hematocrit levels in hospitalized general internal medicine patients. Retrospective cohort study. General internal medicine inpatient service at a tertiary care hospital. All adult patients discharged from the Toronto General Hospital's internal medicine service between January 1 and June 30, 2001. A total of 989 hospitalizations were reviewed and 404 hospitalizations were included in our analysis. Mean (SD) hemoglobin and hematocrit changes during hospitalization were 7.9 (12.6) g/L (Phemoglobin and hematocrit were predicted by the volume of phlebotomy, length of hospital stay, admission hemoglobin/hematocrit value, age, Charlson comorbidity index, and admission intravascular volume status. The volume of phlebotomy remained a strong predictor of drop in hemoglobin and hematocrit after adjusting for other predictors using multivariate analysis (Phemoglobin and hematocrit of 7.0 g/L and 1.9%, respectively. Phlebotomy is highly associated with changes in hemoglobin and hematocrit levels for patients admitted to an internal medicine service and can contribute to anemia. This anemia, in turn, may have significant consequences, especially for patients with cardiorespiratory diseases. Knowing the expected changes in hemoglobin and hematocrit due to diagnostic phlebotomy will help guide when to investigate anemia in hospitalized patients.

  15. Determination of natural in vivo noble-gas concentrations in human blood.

    Directory of Open Access Journals (Sweden)

    Yama Tomonaga

    Full Text Available Although the naturally occurring atmospheric noble gases He, Ne, Ar, Kr, and Xe possess great potential as tracers for studying gas exchange in living beings, no direct analytical technique exists for simultaneously determining the absolute concentrations of these noble gases in body fluids in vivo. In this study, using human blood as an example, the absolute concentrations of all stable atmospheric noble gases were measured simultaneously by combining and adapting two analytical methods recently developed for geochemical research purposes. The partition coefficients determined between blood and air, and between blood plasma and red blood cells, agree with values from the literature. While the noble-gas concentrations in the plasma agree rather well with the expected solubility equilibrium concentrations for air-saturated water, the red blood cells are characterized by a distinct supersaturation pattern, in which the gas excess increases in proportion to the atomic mass of the noble-gas species, indicating adsorption on to the red blood cells. This study shows that the absolute concentrations of noble gases in body fluids can be easily measured using geochemical techniques that rely only on standard materials and equipment, and for which the underlying concepts are already well established in the field of noble-gas geochemistry.

  16. Usefulness of estimation of blood procalcitonin concentration versus C-reactive protein concentration and white blood cell count for therapeutic monitoring of sepsis in neonates

    Directory of Open Access Journals (Sweden)

    Agnieszka Kordek

    2014-12-01

    Full Text Available Aim: This study was intended to assess the clinical usefulness of blood procalcitonin (PCT concentrations for the diagnosis and therapeutic monitoring of nosocomial neonatal sepsis.Material/Methods: The enrolment criterion was sepsis clinically manifesting after three days of life. PCT concentrations were measured in venous blood from 52 infected and 88 uninfected neonates. The results were interpreted against C-reactive protein (CRP concentrations and white blood cell counts (WBC.Results: Differences between the two groups in PCT and CRP concentrations were highly significant. No significant differences between the groups were noted for WBC. The threshold value on the receiver operator characteristic curve was 2.06 ng/mL for PCT (SE 75%; SP 80.68%; PPV 62.22%; NPV 88.75%; AUC 0.805, 5.0 mg/L for CRP (SE 67.44%; SP 73.68%; PPV 42.02%; NPV 88.89%; AUC 0.801, and 11.9 x109/L for WBC (SE 51.16%; SP 50.68%; PPV 23.16%; NPV 78.13%; AUC 0.484. Procalcitonin concentrations decreased 24 hours after initiation of antibiotic therapy and reverted to the control level after 5-7 days. C-reactive protein concentrations began to decline after two days of antibiotic therapy but were still higher than in the control group after 5-7 days of treatment. No significant changes in WBC during the treatment were observed.Conclusions: Procalcitonin concentrations in blood appear to be of use for the diagnosis and therapeutic monitoring of nosocomial infections in neonates as this parameter demonstrates greater sensitivity and specificity than C-reactive protein. White blood cell counts appear to be of little diagnostic value in the early phase of infection or for therapeutic monitoring.

  17. Heme Iron Concentrate and Iron Sulfate Added to Chocolate Biscuits: Effects on Hematological Indices of Mexican Schoolchildren.

    Science.gov (United States)

    Quintero-Gutiérrez, Adrián Guillermo; González-Rosendo, Guillermina; Pozo, Javier Polo; Villanueva-Sánchez, Javier

    2016-08-01

    Food fortification is one of the most effective strategies for increasing iron intake in the population. A simple blind trial was conducted to compare the effect of 2 forms of iron fortification and assess the changes in hemoglobin and iron status indices among preschool children from rural communities. Hemoglobin was evaluated in 47 children aged 3-6 years old. For 72 days (10-week period), children ate Nito biscuits. Thirteen pupils with elevated hemoglobin levels were assigned to the biscuit control group, and pupils with hemoglobin equal to 13.5 mg/dL or less were randomly allocated to consume fortified biscuits with a heme iron concentrate (n = 15) or iron sulfate (n = 19). Changes in hemoglobin, plasma ferritin, and other hematological indices were evaluated with analysis of variance (ANOVA) for repeated measurements. Except mean corpuscular hemoglobin concentrations (+1.27 ± 2.25 g/dL), hematological indices increased significantly across the study: Mean corpuscular volume (+2.2 ± 1.0 f/dL), red blood cells (+0.30 ± 0.37 M/μL), mean corpuscular hemoglobin (+1.8 ± 1.74 pg), hemoglobin (+1.68 ± 0.91 g/dL), hematocrit (+3.43% ± 3.03%), and plasma ferritin (+18.38 ± 22.1 μg/L) were all p effect of the iron-fortified chocolate biscuits in the hemoglobin levels was higher than the control group (+1.1 ± 0.2 g/dL) but no difference was found between consumers of fortified biscuits with heme iron concentrate or iron sulfate (+1.9 ± 0.2 g/dL and +2.0 ± 0.2 g/dL, respectively). Heme iron concentrate and iron sulfate were equally effective in increasing Hb levels and hematological indices. Processed foods were shown to be an effective, valuable, and admissible intervention to prevent anemia in preschool children.

  18. Analyzing prefrontal cortex hemoglobin concentration exchange spectrum in patients with major depressive disorder combined with anxiety and obsession through near-infrared spectroscopy

    Institute of Scientific and Technical Information of China (English)

    刘晓敏

    2014-01-01

    Objective Exploring the characteristics of prefrontal cortex activation in patients of major depressive disorder(MDD)combined with anxiety and obsession through functional near-infrared spectroscopy(fN IRS).Methods Prefrontal cortex hemoglobin concentration exchange of30 MDD patients combined with anxiety and obsession was detected by fN IRS under voice fluency task(VFT),then psychological assessment was made using Hanmilton Depression Scale(HAMD),Hamilton Anxiety Scale

  19. Predictors of Blood Trihalomethane Concentrations in NHANES 1999–2006

    Science.gov (United States)

    Dhingra, Radhika; Blount, Benjamin C.; Steenland, Kyle

    2014-01-01

    Background: Trihalomethanes (THMs) are water disinfection by-products that have been associated with bladder cancer and adverse birth outcomes. Four THMs (bromoform, chloroform, bromodichloromethane, dibromochloromethane) were measured in blood and tap water of U.S. adults in the National Health and Nutrition Examination Survey (NHANES) 1999–2006. THMs are metabolized to potentially toxic/mutagenic intermediates by cytochrome p450 (CYP) 2D6 and CYP2E1 enzymes. Objectives: We conducted exploratory analyses of blood THMs, including factors affecting CYP2D6 and CYP2E1 activity. Methods: We used weighted multivariable regressions to evaluate associations between blood THMs and water concentrations, survey year, and other factors potentially affecting THM exposure or metabolism (e.g., prescription medications, cruciferous vegetables, diabetes, fasting, pregnancy, swimming). Results: From 1999 to 2006, geometric mean blood and water THM levels dropped in parallel, with decreases of 32%–76% in blood and 38%–52% in water, likely resulting, in part, from the lowering of the total THM drinking water standard in 2002–2004. The strongest predictors of blood THM levels were survey year and water concentration (n = 4,232 total THM; n = 4,080 bromoform; n = 4,582 chloroform; n = 4,374 bromodichloromethane; n = 4,464 dibromochloromethane). We detected statistically significant inverse associations with diabetes and eating cruciferous vegetables in all but the bromoform model. Medications did not consistently predict blood levels. Afternoon/evening blood samples had lower THM concentrations than morning samples. In a subsample (n = 230), air chloroform better predicted blood chloroform than water chloroform, suggesting showering/bathing was a more important source than drinking. Conclusions: We identified several factors associated with blood THMs that may affect their metabolism. The potential health implications require further study. Citation: Riederer AM, Dhingra R

  20. Anthroposophic lifestyle influences the concentration of metals in placenta and cord blood

    International Nuclear Information System (INIS)

    Fagerstedt, Sara; Kippler, Maria; Scheynius, Annika; Gutzeit, Cindy; Mie, Axel; Alm, Johan; Vahter, Marie

    2015-01-01

    Allergic diseases develop in genetically susceptible individuals in a complex interplay with the environment, usually early in life. We have previously shown that the anthroposophic lifestyle is associated with reduced risk of allergic disease in children, but details on the influencing environmental factors are largely unknown. This study aims to elucidate if anthroposophic lifestyle influences fetal exposure to selected toxic and essential elements. Randomly selected non-smoking mothers with (n=40) and without (n=40) anthroposophic lifestyle from the prospective birth cohort ALADDIN were included. Concentrations of 12 toxic and essential elements were analyzed in full term placentas and in the erythrocyte fractions of maternal peripheral blood and of umbilical cord blood, using inductively coupled plasma mass spectrometry. Cadmium concentrations in maternal blood and placenta were significantly higher in mothers with an anthroposophic lifestyle (p<0.001), while concentrations in cord blood were generally low, irrespective of lifestyle. Cobalt concentrations were higher in both maternal blood, placenta and cord blood in the anthroposophic group. Lead concentrations were higher in maternal blood and cord blood, but not placenta, of mothers with anthroposophic lifestyle. Analysis of covariance, including lifestyle, parity, maternal age, gestational age, vegetarian diet, use of herbal medicine and occupation in the model, showed that mainly the anthroposophic lifestyle was significantly associated with cadmium concentrations. In conclusion, women with an anthroposophic lifestyle had higher concentrations of cadmium, cobalt and lead concentrations. Cadmium concentrations might have been influenced by a diet rich in vegetables and/or low iron status of the mothers. - Highlights: • Toxic elements in mother–newborn pairs in relation to anthroposophic lifestyle. • Anthroposophic lifestyle was associated with higher levels of cadmium, cobalt and lead. • A diet rich

  1. Anthroposophic lifestyle influences the concentration of metals in placenta and cord blood

    Energy Technology Data Exchange (ETDEWEB)

    Fagerstedt, Sara [The Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (Sweden); Kippler, Maria [Institute of Environmental Medicine, Karolinska Institutet, Box 210, 171 77 Stockholm (Sweden); Scheynius, Annika; Gutzeit, Cindy [Department of Medicine Solna, Translational Immunology Unit, Karolinska Institutet and University Hospital, Stockholm (Sweden); Mie, Axel [The Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (Sweden); Alm, Johan [The Department of Clinical Science and Education, Södersjukhuset, Karolinska Institutet, Stockholm (Sweden); Sachs' Children and Youth Hospital, Södersjukhuset, Stockholm (Sweden); Vahter, Marie, E-mail: marie.vahter@ki.se [Institute of Environmental Medicine, Karolinska Institutet, Box 210, 171 77 Stockholm (Sweden)

    2015-01-15

    Allergic diseases develop in genetically susceptible individuals in a complex interplay with the environment, usually early in life. We have previously shown that the anthroposophic lifestyle is associated with reduced risk of allergic disease in children, but details on the influencing environmental factors are largely unknown. This study aims to elucidate if anthroposophic lifestyle influences fetal exposure to selected toxic and essential elements. Randomly selected non-smoking mothers with (n=40) and without (n=40) anthroposophic lifestyle from the prospective birth cohort ALADDIN were included. Concentrations of 12 toxic and essential elements were analyzed in full term placentas and in the erythrocyte fractions of maternal peripheral blood and of umbilical cord blood, using inductively coupled plasma mass spectrometry. Cadmium concentrations in maternal blood and placenta were significantly higher in mothers with an anthroposophic lifestyle (p<0.001), while concentrations in cord blood were generally low, irrespective of lifestyle. Cobalt concentrations were higher in both maternal blood, placenta and cord blood in the anthroposophic group. Lead concentrations were higher in maternal blood and cord blood, but not placenta, of mothers with anthroposophic lifestyle. Analysis of covariance, including lifestyle, parity, maternal age, gestational age, vegetarian diet, use of herbal medicine and occupation in the model, showed that mainly the anthroposophic lifestyle was significantly associated with cadmium concentrations. In conclusion, women with an anthroposophic lifestyle had higher concentrations of cadmium, cobalt and lead concentrations. Cadmium concentrations might have been influenced by a diet rich in vegetables and/or low iron status of the mothers. - Highlights: • Toxic elements in mother–newborn pairs in relation to anthroposophic lifestyle. • Anthroposophic lifestyle was associated with higher levels of cadmium, cobalt and lead. • A diet rich

  2. Novel Luminescent Probe Based on a Terbium(III) Complex for Hemoglobin Determination

    Science.gov (United States)

    Yegorova, A. V.; Leonenko, I. I.; Aleksandrova, D. I.; Scrypynets, Yu. V.; Antonovich, V. P.; Ukrainets, I. V.

    2014-09-01

    We have studied the spectral luminescent properties of Tb(III) and Eu(III) complexes with a number of novel derivatives of oxoquinoline-3-carboxylic acid amides (L1-L5 ). We have observed quenching of the luminescence of 1:1 Tb(III)-L1-5 complexes by hemoglobin (Hb), which is explained by resonance energy transfer of electronic excitation from the donor (Tb(III)-L1-5 ) to the acceptor (Hb). Using the novel luminescent probe Tb(III)-L1, we have developed a method for determining Hb in human blood. The calibration Stern-Volmer plot is linear in the Hb concentration range 0.6-36.0 μg/mL, detection limit 0.2 μg/mL (3·10-9 mol/L).

  3. Hemoglobin alpha 2 gene +861 G>A polymorphism in Turkish ...

    African Journals Online (AJOL)

    Dilay Ciglidag Dungul

    carrying individuals with intact beta globin gene. DNA was extracted from peripheral blood sam- ples of seven healthy carrier individuals who have abnormal hemoglobin variants and 16 control individuals from Turkey. Complete coding and intronic sequences of HBA1 and HBA2 genes were amplified by polymerase chain ...

  4. Replication and Characterization of Association between ABO SNPs and Red Blood Cell Traits by Meta-Analysis in Europeans.

    Directory of Open Access Journals (Sweden)

    Stela McLachlan

    Full Text Available Red blood cell (RBC traits are routinely measured in clinical practice as important markers of health. Deviations from the physiological ranges are usually a sign of disease, although variation between healthy individuals also occurs, at least partly due to genetic factors. Recent large scale genetic studies identified loci associated with one or more of these traits; further characterization of known loci and identification of new loci is necessary to better understand their role in health and disease and to identify potential molecular mechanisms. We performed meta-analysis of Metabochip association results for six RBC traits-hemoglobin concentration (Hb, hematocrit (Hct, mean corpuscular hemoglobin (MCH, mean corpuscular hemoglobin concentration (MCHC, mean corpuscular volume (MCV and red blood cell count (RCC-in 11 093 Europeans from seven studies of the UCL-LSHTM-Edinburgh-Bristol (UCLEB Consortium. We identified 394 non-overlapping SNPs in five loci at genome-wide significance: 6p22.1-6p21.33 (with HFE among others, 6q23.2 (with HBS1L among others, 6q23.3 (contains no genes, 9q34.3 (only ABO gene and 22q13.1 (with TMPRSS6 among others, replicating previous findings of association with RBC traits at these loci and extending them by imputation to 1000 Genomes. We further characterized associations between ABO SNPs and three traits: hemoglobin, hematocrit and red blood cell count, replicating them in an independent cohort. Conditional analyses indicated the independent association of each of these traits with ABO SNPs and a role for blood group O in mediating the association. The 15 most significant RBC-associated ABO SNPs were also associated with five cardiometabolic traits, with discordance in the direction of effect between groups of traits, suggesting that ABO may act through more than one mechanism to influence cardiometabolic risk.

  5. A low-hemolysis blood aspirator conserves blood during surgery.

    Science.gov (United States)

    Clague, C T; Blackshear, P L

    1995-01-01

    Blood damage caused by traditional vacuum-operated suction tubes, particularly when air is aspirated along with the blood, usually exceeds damage from all other components. In addition to platelet injury, there is a high degree of hemolysis, which leads to high plasma hemoglobin levels and reduces the number of red blood cells available for reinfusion during cases of blood conservation, such as autologous transfusion and cardiac bypass. This work was undertaken to minimize hemolysis, and the accompanying platelet destruction, during aspiration, with the design of a jet-driven aspirator that separates and removes air from blood immediately within the suction tip. The jet-driven aspirator can suction blood at a range of rates from 100 to at least 700 ml/min, separates and removes 80-100% of aspirated air, operates at any orientation, and generates subatmospheric pressures on the order of only 1 inch H2O. In-vitro hemolysis testing showed a significant reduction in average plasma hemoglobin release, from 19.4 mg/dl to 1.8 mg/dl, when air was removed during blood aspiration. In comparative testing with a conventional vacuum suction tube, the jet-driven aspirator showed significantly less hemolysis than the conventional aspirator at comparable rates of air and blood aspiration.

  6. Modeling hemoglobin at optical frequency using the unconditionally stable fundamental ADI-FDTD method.

    Science.gov (United States)

    Heh, Ding Yu; Tan, Eng Leong

    2011-04-12

    This paper presents the modeling of hemoglobin at optical frequency (250 nm - 1000 nm) using the unconditionally stable fundamental alternating-direction-implicit finite-difference time-domain (FADI-FDTD) method. An accurate model based on complex conjugate pole-residue pairs is proposed to model the complex permittivity of hemoglobin at optical frequency. Two hemoglobin concentrations at 15 g/dL and 33 g/dL are considered. The model is then incorporated into the FADI-FDTD method for solving electromagnetic problems involving interaction of light with hemoglobin. The computation of transmission and reflection coefficients of a half space hemoglobin medium using the FADI-FDTD validates the accuracy of our model and method. The specific absorption rate (SAR) distribution of human capillary at optical frequency is also shown. While maintaining accuracy, the unconditionally stable FADI-FDTD method exhibits high efficiency in modeling hemoglobin.

  7. Radioimmunochemical characterization of hemoglobins Lepore and Kenya: unique antigenic determinants located on hybrid hemoglobins

    International Nuclear Information System (INIS)

    Garver, F.A.; Altay, G.; Baker, M.M.; Gravely, M.; Huisman, T.H.J.

    1978-01-01

    Antisera were produced in rabbits to the three known types of Lepore hemoglobins, which contain hybrid delta-β non-α-chains, and to hemoglobin Kenya, which has a hybrid γ-β non-α-chain. By using a sensitive radioimmunoassay technique, the absorbed antisera were shown to contain an antibody population that was specific for the hybrid hemoglobin and did not cross-react with normal hemoglobins. However, with the absorbed Lepore-specific antisera, the three known types of Lepore hemoglobins were antigenically indistinguishable from each other, suggesting that antibodies are not produced to the primary structural differences which define the three non-α-chains of the Lepore hemoglobins. These studies demonstrate that the non-α-subunits of hemoglobins Lepore and Kenya possess unique antigenic determinant sites, evidently resulting from an altered polypeptide conformation

  8. HIV and other predictors of serum folate, serum ferritin, and hemoglobin in pregnancy

    DEFF Research Database (Denmark)

    Friis, Henrik; Gomo, E; Kæstel, Pernille

    2001-01-01

    BACKGROUND: Folate and iron status and hemoglobin concentrations are important to maternal and infant health. OBJECTIVE: Our goal was to identify predictors of serum folate, serum ferritin, and hemoglobin. DESIGN: This was a cross-sectional study of 1669 pregnant women (22-35 wk of gestation) in ...

  9. Prediction model for high glycated hemoglobin concentration among ethnic Chinese in Taiwan

    Directory of Open Access Journals (Sweden)

    Lee Bai-Chin

    2010-09-01

    Full Text Available Abstract Background This study aimed to construct a prediction model to identify subjects with high glycated hemoglobin (HbA1c levels by incorporating anthropometric, lifestyle, clinical, and biochemical information in a large cross-sectional ethnic Chinese population in Taiwan from a health checkup center. Methods The prediction model was derived from multivariate logistic regression, and we evaluated the performance of the model in identifying the cases with high HbA1c levels (> = 7.0%. In total 17,773 participants (age > = 30 years were recruited and 323 participants (1.8% had high HbA1c levels. The study population was divided randomly into two parts, with 80% as the derivation data and 20% as the validation data. Results The point-based clinical model, including age (maximal 8 points, sex (1 point, family history (3 points, body mass index (2 points, waist circumference (4 points, and systolic blood pressure (3 points reached an area under the receiver operating characteristic curve (AUC of 0.723 (95% confidence interval, 0.677- 0.769 in the validation data. Adding biochemical measures such as triglycerides and HDL cholesterol improved the prediction power (AUC, 0.770 [0.723 - 0.817], P = Conclusions A prediction model was constructed for the prevalent risk of high HbA1c, which could be useful in identifying high risk subjects for diabetes among ethnic Chinese in Taiwan.

  10. Patient blood management in elective total hip- and knee-replacement surgery (part 2): a randomized controlled trial on blood salvage as transfusion alternative using a restrictive transfusion policy in patients with a preoperative hemoglobin above 13 g/dl.

    Science.gov (United States)

    So-Osman, Cynthia; Nelissen, Rob G H H; Koopman-van Gemert, Ankie W M M; Kluyver, Ewoud; Pöll, Ruud G; Onstenk, Ron; Van Hilten, Joost A; Jansen-Werkhoven, Thekla M; van den Hout, Wilbert B; Brand, Ronald; Brand, Anneke

    2014-04-01

    Patient blood management is introduced as a new concept that involves the combined use of transfusion alternatives. In elective adult total hip- or knee-replacement surgery patients, the authors conducted a large randomized study on the integrated use of erythropoietin, cell saver, and/or postoperative drain reinfusion devices (DRAIN) to evaluate allogeneic erythrocyte use, while applying a restrictive transfusion threshold. Patients with a preoperative hemoglobin level greater than 13 g/dl were ineligible for erythropoietin and evaluated for the effect of autologous blood reinfusion. Patients were randomized between autologous reinfusion by cell saver or DRAIN or no blood salvage device. Primary outcomes were mean intra- and postoperative erythrocyte use and proportion of transfused patients (transfusion rate). Secondary outcome was cost-effectiveness. In 1,759 evaluated total hip- and knee-replacement surgery patients, the mean erythrocyte use was 0.19 (SD, 0.9) erythrocyte units/patient in the autologous group (n = 1,061) and 0.22 (0.9) erythrocyte units/patient in the control group (n = 698) (P = 0.64). The transfusion rate was 7.7% in the autologous group compared with 8.3% in the control group (P = 0.19). No difference in erythrocyte use was found between cell saver and DRAIN groups. Costs were increased by €298 per patient (95% CI, 76 to 520). In patients with preoperative hemoglobin levels greater than 13 g/dl, autologous intra- and postoperative blood salvage devices were not effective as transfusion alternatives: use of these devices did not reduce erythrocyte use and increased costs.

  11. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  12. A standardized multidisciplinary approach reduces the use of allogeneic blood products in patients undergoing cardiac surgery.

    Science.gov (United States)

    Van der Linden, P; De Hert, S; Daper, A; Trenchant, A; Jacobs, D; De Boelpaepe, C; Kimbimbi, P; Defrance, P; Simoens, G

    2001-10-01

    Individual and institutional practices remain an independent predictor factor for allogeneic blood transfusion. Application of a standardized multidisciplinary transfusion strategy should reduce the use of allogeneic blood transfusion in major surgical patients. This prospective non randomized observational study evaluated the effects of a standardized multidisciplinary transfusion strategy on allogeneic blood products exposure in patients undergoing non-emergent cardiac surgery. The developed strategy involved a standardized blood conservation program and a multidisciplinary allogeneic blood transfusion policy based mainly on clinical judgement, not only on a specific hemoglobin concentration. Data obtained in a first group including patients operated from September 1997 to August 1998 (Group pre: n=321), when the transfusion strategy was progressively developed, were compared to those obtained in a second group, including patients operated from September 1998 to August 1999 (Group post: n=315) when the transfusion strategy was applied uniformly. Patient populations and surgical procedures were similar. Patients in Group post underwent acute normovolemic hemodilution more frequently, had a higher core temperature at arrival in the intensive care unit and presented lower postoperative blood losses at day one. Three hundred forty units of packed red blood cells were transfused in 33% of the patients in Group pre whereas 161 units were transfused in 18% of the patients in Group post (P <0.001). Pre- and postoperative hemoglobin concentrations, mortality and morbidity were not different among groups. Development of a standardized multidisciplinary transfusion strategy markedly reduced the exposure of cardiac surgery patients to allogeneic blood.

  13. Hemoglobin oxygen affinity in patients with cystic fibrosis.

    Directory of Open Access Journals (Sweden)

    Dieter Böning

    Full Text Available In patients with cystic fibrosis lung damages cause arterial hypoxia. As a typical compensatory reaction one might expect changes in oxygen affinity of hemoglobin. Therefore position (standard half saturation pressure P50st and slope (Hill's n of the O2 dissociation curve as well as the Bohr coefficients (BC for CO2 and lactic acid were determined in blood of 14 adult patients (8 males, 6 females and 14 healthy controls (6 males, 8 females. While Hill's n amounted to approximately 2.6 in all subjects, P50st was slightly increased by 1 mmHg in both patient groups (controls male 26.7 ± 0.2, controls female 27.0 ± 0.1, patients male 27.7 ± 0.5, patients female 28.0 ± 0.3 mmHg; mean and standard error, overall p<0.01. Main cause was a rise of 1-2 µmol/g hemoglobin in erythrocytic 2,3-biphosphoglycerate concentration. One patient only, clearly identified as an outlier and with the mutation G551D, showed a reduction of both P50st (24.5 mmHg and [2,3-biphosphoglycerate] (9.8 µmol/g hemoglobin. There were no differences in BCCO2, but small sex differences in the BC for lactic acid in the controls which were not detectable in the patients. Causes for the right shift of the O2 dissociation curve might be hypoxic stimulation of erythrocytic glycolysis and an increased red cell turnover both causing increased [2,3-biphosphoglycerate]. However, for situations with additional hypercapnia as observed in exercising patients a left shift seems to be a more favourable adaptation in cystic fibrosis. Additionally when in vivo PO2 values were corrected to the standard conditions they mostly lay left of the in vitro O2 dissociation curve in both patients and controls. This hints to unknown fugitive factors influencing oxygen affinity.

  14. Impact of Mean Cell Hemoglobin on Hb A1c-Defined Glycemia Status.

    Science.gov (United States)

    Rodriguez-Segade, Santiago; Garcia, Javier Rodriguez; García-López, José M; Gude, Francisco; Casanueva, Felipe F; Rs-Alonso, Santiago; Camiña, Félix

    2016-12-01

    Several hematological alterations are associated with altered hemoglobin A 1c (Hb A 1c ). However, there have been no reports of their influence on the rates of exceeding standard Hb A 1c thresholds by patients for whom Hb A 1c determination is requested in clinical practice. The initial data set included the first profiles (complete blood counts, Hb A 1c , fasting glucose, and renal and hepatic parameters) of all adult patients for whom such a profile was requested between 2008 and 2013 inclusive. After appropriate exclusions, 21844 patients remained in the study. Linear and logistic regression models were adjusted for demographic, hematological, and biochemical variables excluded from the predictors. Mean corpuscular hemoglobin (MCH) and mean corpuscular volume (MCV) correlated negatively with Hb A 1c . Fasting glucose, MCH, and age emerged as predictors of Hb A 1c in a stepwise regression that discarded sex, hemoglobin, MCV, mean corpuscular hemoglobin concentration (MCHC), serum creatinine, and liver disease. Mean Hb A 1c in MCH interdecile intervals fell from 6.8% (51 mmol/mol) in the lowest (≤27.5 pg) to 6.0% (43 mmol/mol) in the highest (>32.5 pg), with similar results for MCV. After adjustment for fasting glucose and other correlates of Hb A 1c , a 1 pg increase in MCH reduced the odds of Hb A 1c -defined dysglycemia, diabetes and poor glycemia control by 10%-14%. For at least 25% of patients, low or high MCH or MCV levels are associated with increased risk of an erroneous Hb A 1c -based identification of glycemia status. Although causality has not been demonstrated, these parameters should be taken into account in interpreting Hb A 1c levels in clinical practice. © 2016 American Association for Clinical Chemistry.

  15. LETTER TO THE EDITOR: Arterio-venous flow between monochorionic twins determined during intra-uterine transfusion. Nonlinear decay of adult red blood cells

    Science.gov (United States)

    van Gemert, Martin J. C.; Pasman, Suzanne A.; van den Wijngaard, Jeroen P. H. M.; Lopriore, Enrico; Vandenbussche, Frank P. H. A.

    2008-07-01

    Recently, we derived equations relating the flow of adult red blood cells through a placental arterio-venous anastomosis with intra-uterine and post-natal measured adult hemoglobin concentrations. In this letter, we re-derived the equations, now including a more realistic nonlinear decay of adult red blood cells, and re-evaluated the measurement accuracy of the arterio-venous flow and the lifetime of the red blood cells.

  16. The Cut-off Value of Blood Mercury Concentration in Relation to Insulin Resistance

    Directory of Open Access Journals (Sweden)

    Seok-Hoon Lee

    2017-09-01

    Full Text Available Background : Increased blood mercury concentration is associated with inflammation, and chronic inflammation can cause insulin resistance. We examined the cut-off value of blood mercury in relation to an increased score on the homeostasis model assessment for insulin resistance (HOMA-IR. Methods : We used data from the Korean National Health and Nutrition Examination Survey (2008–2010. Relevant data from 5,184 subjects (2,523 men and 2,661 women were analyzed cross-sectionally. General linear analysis was performed to evaluate the relationship between HOMA-IR score and blood mercury concentration. In addition, we determined the cut-off value of blood mercury concentration in relation to increased HOMA-IR score (> 2.34 using an ROC curve. Results : The mean value of blood mercury concentration in men and women was 5.88 μg/L and 4.11 μg/L, respectively. In men, comparing to the first quartile, HOMA-IR score increased significantly in the third and fourth blood mercury quartiles. In women, however, the increase in HOMA-IR score was not significant. The cut-off value that best represented the association between increased HOMA-IR score and blood mercury concentration in men was found to be 4.71 μg/L. Conclusion : Blood mercury concentration was associated with increased HOMA-IR score in men, and the cut-off value of blood mercury concentration that was correlated with increased HOMA-IR score was around 4.71 μg/L.

  17. Carbon monoxide reduces near-infrared spectroscopy determined 'total' hemoglobin

    DEFF Research Database (Denmark)

    Niemann, Mads J; Sørensen, Henrik; Siebenmann, Christoph

    2017-01-01

    with CO (1.5 mL kg-1) was added to the circuit. Two NIRS systems (NIRO-200NX and INVOS-5100) assessed ScO2 as the ratio of oxygenated to deoxygenated hemoglobin, while venous blood samples were analyzed for carboxyhemoglobin (COHb). After CO/O2 rebreathing COHb increased to 8.7% (IQR; 7.9-9.4; p = .004...... to normoxia (68.9 ± 6.9%; p hemoglobin decreased (by 19.7 μM (median; IQR 2.8-34.8; p = .016) and 37.3 μM (30.8-46.6; p = .004), respectively) during inhalation of CO/O2 compared...... to inhalation of O2. Therefore, NIRO-200NX determined 'total' hemoglobin (sum of O2Hb and HHb) decreased (by 62.1 μM; 44.5-78.2; p = .001). In conclusion, exposure to CO did not increase MCAVmean, and neither NIRO-200NX nor INVOS-5100 detected a change in ScO2 when CO was added to inhalation of oxygen...

  18. Effect of ionizing radiation on biochemical variable in blood of workers and cancer patients

    International Nuclear Information System (INIS)

    Alwan, I. F.; Mohamed, H. A.; Mohamed, N.A

    2012-12-01

    This research is concerned threw on the possible between the chemical evidence of life on the process of oxidative stress malonaldehyde (MDA) and the glutathione -S- transfers (GST) enzyme as the concentration of amount of hemoglobin, and the proportion of (packed cell volume) PCV and concentration of the amount (fibrinogen) as a result of exposure to ionizing radiation of the isotope technetium-99 m, is used for treatment and imaging up to (10-30 m ci) and the serum of the three groups were used. Were divided the three groups to group one (50) for the radiation patient who has cancer and the second group (50) of workers in the nuclear medicine centers and third groups (50) healthy volunteers of non-exposed to radiation (control group). The oxidative peroxides rate was determined (MDA), also the activity of (GST) enzyme and some blood physiological compared with the control group. This study indicated that there was a significant difference at (p<0.01) on the action of GST enzyme and MDA and concentration of amount of hemoglobin, (fibrinogen) and PCV in the blood of workers in the nuclear medicine centers and the radiations patient groups compared with the control group. (Author)

  19. Modification of postnatal hemoglobin level and hematocrit value in the peripheral blood of mice after gamma radiation in utero by MPG (2-mercaptopropionylglycine)

    International Nuclear Information System (INIS)

    Goyal, P.K.; Kumar, S.; Dev, P.K.

    1980-01-01

    Pregnant Swiss albino mice were irradiated with oamma radiation at post-conception days 14.5, 16.25 and 18.25. Hemoglobin level and hematocrit value in the peripheral blood of the male offsprings were found to be below normal during the early postnatal development. The value became normal from 4 week onwards. However these values were found to be significantly elevated in the early postnatal development of the male offsprings of the mice which were administered MPG before irradiation. The possible radioprotective mechanism of MPG is discussed. (M.G.B.)

  20. A practical platform for blood biomarker study by using global gene expression profiling of peripheral whole blood.

    Directory of Open Access Journals (Sweden)

    Ze Tian

    Full Text Available Although microarray technology has become the most common method for studying global gene expression, a plethora of technical factors across the experiment contribute to the variable of genome gene expression profiling using peripheral whole blood. A practical platform needs to be established in order to obtain reliable and reproducible data to meet clinical requirements for biomarker study.We applied peripheral whole blood samples with globin reduction and performed genome-wide transcriptome analysis using Illumina BeadChips. Real-time PCR was subsequently used to evaluate the quality of array data and elucidate the mode in which hemoglobin interferes in gene expression profiling. We demonstrated that, when applied in the context of standard microarray processing procedures, globin reduction results in a consistent and significant increase in the quality of beadarray data. When compared to their pre-globin reduction counterparts, post-globin reduction samples show improved detection statistics, lowered variance and increased sensitivity. More importantly, gender gene separation is remarkably clearer in post-globin reduction samples than in pre-globin reduction samples. Our study suggests that the poor data obtained from pre-globin reduction samples is the result of the high concentration of hemoglobin derived from red blood cells either interfering with target mRNA binding or giving the pseudo binding background signal.We therefore recommend the combination of performing globin mRNA reduction in peripheral whole blood samples and hybridizing on Illumina BeadChips as the practical approach for biomarker study.

  1. Exercise timing and blood lactate concentrations in individuals with type 2 diabetes.

    Science.gov (United States)

    Heden, Timothy D; Liu, Ying; Kanaley, Jill A

    2017-07-01

    The purpose of this study was to characterize how resistance exercise prior to or after a meal alters fasting and postprandial blood lactate concentrations in individuals with type 2 diabetes. Obese individuals with type 2 diabetes (N = 12) completed three 2-day trials, including (i) no exercise (NoEx), (ii) resistance exercise prior to dinner (Ex-M), and (iii) resistance exercise beginning at 45 min postdinner (M-Ex). During day 1 of each trial, fasting and postprandial blood lactate concentrations, perceived exertion, and substrate oxidation were measured, and subsequently on day 2 the following morning fasting blood lactate was measured. The premeal lactate incremental area under the curve (iAUC) during Ex-M (109 ± 66 mmol·L -1 ·1.6 h -1 ) was over 100-fold greater (P 0.05). Perceived exertion, substrate oxidation, or fasting blood lactate concentrations the day after testing were not different between trials. Blood lactate concentrations during acute resistance exercise are greater when exercise is performed in the postprandial period. Acute resistance exercise performed the night prior does not alter fasting blood lactate concentrations the following morning.

  2. Temporal stability of blood lead concentrations in adults exposed only to environmental lead

    Energy Technology Data Exchange (ETDEWEB)

    Delves, H T; Sherlock, J C; Quinn, M J

    1984-08-01

    The temporal stability of blood lead concentrations of 21 health adults (14 men and 7 women) exposed only to environmental lead was assessed by analysis of 253 blood specimens collected serially over periods from 7 to 11 months. The women had lower blood lead concentrations (mean 8.5, range 7.4-10.8 micrograms/100 ml) than did the men (mean 12.2, range 8.6-15.8 micrograms/100 ml). These are within the expected ranges for non-occupationally exposed persons. Blood lead concentrations in the serial specimens from both men and women changed very little over the study period, with standard deviations of less than 0.5 micrograms/100 ml for the majority of individual mean concentrations: for all except low subjects the standard deviations were less than 0.8 micrograms/100 ml. Two subjects showed significant changes in blood lead concentrations during the study. A temporary increase in oral lead intake was identified for one of these subjects. In the absence of substantial changes in lead exposure blood lead levels in adults are remarkably stable and for their environmental monitoring a single blood lead concentration is an excellent biological indicator.

  3. Evaluation of a blood conservation strategy in the intensive care unit: a prospective, randomised study.

    LENUS (Irish Health Repository)

    Mahdy, Saad

    2009-06-01

    Anemia is a common problem in the ICU population. Most patients are anemic at admission, their hemoglobin concentrations declining further thereafter. The aim of the present study was to evaluate the effect of a combination strategy, involving closed arterial blood gas sampling and the use of pediatric vials for phlebotomy (Group A), on the sampling-induced blood loss and the rate of decline in hemoglobin in adult ICU patients. Combination (Group A) was compared to the current standard technique of arterial line sampling and adult vial phlebotomy (Group B) in a prospective, randomised, ethically-approved trial for the first 72 hours of their ICU stay. Peri-operative, oncology, coagulopathic and uremic patients were excluded. All other ICU patients with arterial cannulae and predicted to stay beyond 3 days, were enrolled.

  4. Peripheral blood count in preoperative radiotherapy (with radiomodificators) of lung cancer

    International Nuclear Information System (INIS)

    Demidchik, Yu.E.; Zharkov, V.V.; Prokhorova, V.I.; Rubanova, C.Z.

    1989-01-01

    Indices of peripheral blood in 215 patients with lung cancer during preoperative radiation using hyperglycemia or metronidazole are studied. It is shown that after preoperative radiotherapy, when radiomodifying effects are not used, the content of erythrocytes, thrombocytes, leukocytes, the concentration of hemoglobin in peripheral blood, as well as erythrocyte sedimentation rare didn't change. Functional disorders of the leukopoietic function and the thrombopoietic function of bone marrow when using metronidazole are registered when applying various types of preoperative radiotherapy. Lymphopenia is established when using various types of radiotherapy with radiomodificators

  5. Top-Down-Assisted Bottom-Up Method for Homologous Protein Sequencing: Hemoglobin from 33 Bird Species

    Science.gov (United States)

    Song, Yang; Laskay, Ünige A.; Vilcins, Inger-Marie E.; Barbour, Alan G.; Wysocki, Vicki H.

    2015-11-01

    Ticks are vectors for disease transmission because they are indiscriminant in their feeding on multiple vertebrate hosts, transmitting pathogens between their hosts. Identifying the hosts on which ticks have fed is important for disease prevention and intervention. We have previously shown that hemoglobin (Hb) remnants from a host on which a tick fed can be used to reveal the host's identity. For the present research, blood was collected from 33 bird species that are common in the U.S. as hosts for ticks but that have unknown Hb sequences. A top-down-assisted bottom-up mass spectrometry approach with a customized searching database, based on variability in known bird hemoglobin sequences, has been devised to facilitate fast and complete sequencing of hemoglobin from birds with unknown sequences. These hemoglobin sequences will be added to a hemoglobin database and used for tick host identification. The general approach has the potential to sequence any set of homologous proteins completely in a rapid manner.

  6. Alpha chain hemoglobins with electrophoretic mobility similar to that of hemoglobin S in a newborn screening program.

    Science.gov (United States)

    Silva, Marcilene Rezende; Sendin, Shimene Mascarenhas; Araujo, Isabela Couto de Oliveira; Pimentel, Fernanda Silva; Viana, Marcos Borato

    2013-01-01

    To characterize alpha-chain variant hemoglobins with electric mobility similar to that of hemoglobin S in a newborn screening program. β(S) allele and alpha-thalassemia deletions were investigated in 14 children who had undefined hemoglobin at birth and an electrophoretic profile similar to that of hemoglobin S when they were six months old. Gene sequencing and restriction enzymes (DdeI, BsaJI, NlaIV, Bsu36I and TaqI) were used to identify hemoglobins. Clinical and hematological data were obtained from children who attended scheduled medical visits. THE FOLLOWING ALPHA CHAIN VARIANTS WERE FOUND: seven children with hemoglobin Hasharon [alpha2 47(CE5) Asp>His, HbA2:c.142G>C], all associated with alpha-thalassemia, five with hemoglobin Ottawa [alpha1 15(A13) Gly>Arg, HBA1:c.46G>C], one with hemoglobin St Luke's [alpha1 95(G2) Pro>Arg, HBA1:c.287C>G] and another one with hemoglobin Etobicoke [alpha212 84(F5) Ser>Arg, HBA212:c.255C>G]. Two associations with hemoglobin S were found: one with hemoglobin Ottawa and one with hemoglobin St Luke's. The mutation underlying hemoglobin Etobicoke was located in a hybrid α212 allele in one child. There was no evidence of clinically relevant hemoglobins detected in this study. Apparently these are the first cases of hemoglobin Ottawa, St Luke's, Etobicoke and the α212 gene described in Brazil. The hemoglobins detected in this study may lead to false diagnosis of sickle cell trait or sickle cell disease when only isoelectric focusing is used in neonatal screening. Additional tests are necessary for the correct identification of hemoglobin variants.

  7. Detection of Sickle Cell Hemoglobin in Haiti by Genotyping and Hemoglobin Solubility Tests

    Science.gov (United States)

    Carter, Tamar E.; von Fricken, Michael; Romain, Jean R.; Memnon, Gladys; St. Victor, Yves; Schick, Laura; Okech, Bernard A.; Mulligan, Connie J.

    2014-01-01

    Sickle cell disease is a growing global health concern because infants born with the disorder in developing countries are now surviving longer with little access to diagnostic and management options. In Haiti, the current state of sickle cell disease/trait in the population is unclear. To inform future screening efforts in Haiti, we assayed sickle hemoglobin mutations using traditional hemoglobin solubility tests (HST) and add-on techniques, which incorporated spectrophotometry and insoluble hemoglobin separation. We also generated genotype data as a metric for HST performance. We found 19 of 202 individuals screened with HST were positive for sickle hemoglobin, five of whom did not carry the HbS allele. We show that spectrophotometry and insoluble hemoglobin separation add-on techniques could resolve false positives associated with the traditional HST approach, with some limitations. We also discuss the incorporation of insoluble hemoglobin separation observation with HST in suboptimal screening settings like Haiti. PMID:24957539

  8. Moessbauer studies of hemoglobin in high altitude polycythemia

    International Nuclear Information System (INIS)

    Zhang Xiufang; Shen Linming; Chen Songsen; Ao Zhaohui; Liu Yuanyuan; Gao Naifei; Zheng Yuanming; Shong Liangquan

    1990-01-01

    The Moessbauer spectra have been measured in erythrocytes from normal adults and the patients with high altitude polycythemia (HAPC). The results indicated that two subspectra ''a'' and ''b'', corresponding to oxy- and deoxyhemoglobin respectively, were present in all blood samples, and a third subspectrum ''c'' was found to exist in almost all samples from the patients. The parameters of the third subspectra ''c1'' in most samples from the patients were similar to those of carbon monoxyhemoglobin. The components were considered to be the denatured hemoglobin in RBCs (red blood cells). Together with clinical analysis, a possible mechanism of HAPC has been discussed. (orig.)

  9. Intraoperative blood loss and blood transfusion requirements in patients undergoing orthognathic surgery.

    Science.gov (United States)

    Faverani, Leonardo Perez; Ramalho-Ferreira, Gabriel; Fabris, André Luis Silva; Polo, Tárik Ocon Braga; Poli, Guilherme Henrique Souza; Pastori, Cláudio Maldonado; Marzola, Clóvis; Assunção, Wirley Gonçalves; Garcia-Júnior, Idelmo Rangel

    2014-09-01

    Procedures for the surgical correction of dentofacial deformities may produce important complications, whether due to the potential for vascular injury or to prolonged surgery, both of which may lead to severe blood loss. Fluid replacement with crystalloid, colloid, or even blood products may be required. The aim of this study was to assess blood loss and transfusion requirements in 45 patients (18 males and 27 females; mean age 29.29 years, range 16-52 years) undergoing orthognathic surgery, assigned to one of two groups according to procedure type-rapid maxillary expansion or double-jaw orthognathic surgery. Preoperative hemoglobin and hematocrit levels and intraoperative blood loss were measured. There was a substantial individual variation in pre- and postoperative hemoglobin values (10.3-17 and 8.8-15.4 g/dL, respectively; p surgery and follow meticulous protocols to minimize the risks.

  10. Patterns of glycemic control using glycosylated hemoglobin in diabetics

    Directory of Open Access Journals (Sweden)

    Arunpreet Singh Kahlon

    2011-01-01

    Full Text Available Aim : Till now estimation of blood glucose is the highly effective method for diagnosing diabetes mellitus but it provides a short-term picture of control. More evidence is required to prove that plasma glucose and glycosylated hemoglobin levels together gives a better estimate of glycemic control and compliance with treatment. Indian diabetes risk score (IDRS is a simplified screening tool for identifying undiagnosed diabetic subjects, requires minimum time, and effort and can help to considerably reduce the costs of screening. Objective : To study patterns of glycemic control using glycosylated hemoglobin in diabetic patients. To find out correlation between levels of plasma glucose and glycosylated hemoglobin in diabetics and to calculate IDRS of the study population. Materials and Methods : A cross sectional study was conducted among 300 known diabetic patients attending outpatient department of a rural medical college in Haryana, India. Following standard procedures and protocols FPG and glycosylated hemoglobin were measured to find out a pattern of glycemic control in them after taking their written and informed consent. A correlation between the levels of glycosylated hemoglobin and fasting blood glucose was also calculated. These patients were made to fill a performa and their demographic and clinical risk factors were noted and based on this, their IDRS was calculated. This was done to validate the IDRS in Indian rural population. Results : Fifty-two percent of the population had fasting plasma glucose level between 125-150 mg/dl, 21% had this level between 151-175 mg/dl. Thirteen percent of the study subjects had HbA1C between 6.5-7.5, more than half (57.3% had this value between 7.5-8.5, 12% and 18% had values between 8.5-9.5 and 9.5-10.5, respectively. Twelve percent of the participants had HbA1C level higher than 10.5. Correlation of fasting plasma glucose level and HbA1C was also studied and found that correlation coefficient came

  11. Establishment of reference intervals for complete blood count parameters during normal pregnancy in Beijing.

    Science.gov (United States)

    Li, Aiwei; Yang, Shuo; Zhang, Jie; Qiao, Rui

    2017-11-01

    To observe the changes of complete blood count (CBC) parameters during pregnancy and establish appropriate reference intervals for healthy pregnant women. Healthy pregnant women took the blood tests at all trimesters. All blood samples were processed on Sysmex XE-2100. The following CBC parameters were analyzed: red blood cell count (RBC), hemoglobin (Hb), hematocrit (Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), red blood cell distribution width (RDW), platelet count (PLT), mean platelet volume (MPV), platelet distribution width (PDW), white blood cell count (WBC), and leukocyte differential count. Reference intervals were established using the 2.5th and 97.5th percentile of the distribution. Complete blood count parameters showed dynamic changes during trimesters. RBC, Hb, Hct declined at trimester 1, reaching their lowest point at trimester 2, and began to rise again at trimester 3. WBC, neutrophil count (Neut), monocyte count (MONO), RDW, and PDW went up from trimester 1 to trimester 3. On the contrary, MCHC, lymphocyte count (LYMPH), PLT, and MPV gradually descended during pregnancy. There were statistical significances in all CBC parameters between pregnant women and normal women, regardless of the trimesters (Ppregnancy) as follows: RBC 4.50 vs 3.94×10 12 /L, Hb 137 vs 120 g/L, WBC 5.71 vs 9.06×10 9 /L, LYMPH% 32.2 vs 18.0, Neut% 58.7 vs 75.0, and PLT 251 vs 202×10 9 /L. The changes of CBC parameters during pregnancy are described, and reference intervals for Beijing pregnant women are demonstrated in this study. © 2017 Wiley Periodicals, Inc.

  12. Clinical and Surgical Strategies for Avoiding or Reducing Allogeneic Blood Transfusions.

    Science.gov (United States)

    Dos Santos, Antonio Alceu; Baumgratz, Jose Francisco; Vila, Jose Henrique Andrade; Castro, Rodrigo Moreira; Bezerra, Rodrigo Freire

    2016-04-01

    Blood transfusions have still been used as a standard therapy to treat severe anemia. Current evidences point to both excessive allogeneic blood consumption and decreased donations, which result in reduced stocks in blood banks. Several studies have increasingly suggested a more restrictive transfusion practice for blood products. Currently, a number of autologous blood conservation protocols in surgeries have been noted. We report a case of severe anemia with 2.9 g/dL hemoglobin, which was successfully handled without using the standard therapy to treat anemia with hemotransfusions. Such a case of severe anemia condition resulted after the patient was submitted to ascending aortic aneurism repair, valvar aortic replacement, reimplantation of right coronary ostium, followed by a coronary artery bypass grafting and several postoperative complications. The main clinical and surgical strategies used in this case to avoid blood transfusions were acute normovolemic hemodilution, intraoperative blood cell salvage, and meticulous hemostasis, beyond epsilon-aminocaproic acid, desmopressin, prothrombin complex concentrate, human fibrinogen concentrate, factor VIIa recombinant, erythropoietin and hyperoxic ventilation.

  13. Study of Gamma-Hydroxybutyric Acid (GHB Concentrations in Postmortem Blood and Urine

    Directory of Open Access Journals (Sweden)

    Huda M Hassan

    2015-12-01

    Full Text Available Gamma-hydroxybutyric acid (GHB is present in blood and urine of the general population as an endogenous compound. The published concentrations in postmortem blood ranged from 0-168 mg/L in cases with no previous history of GHB use. Interpretation of GHB results should be carefully considered due to the wide distribution of endogenous concentrations. The objectives of this study are to evaluate and verify the accuracy of a proposed published (50 mg/L cut-off in 120 blood and 64 urine samples in postmortem cases selected randomly, and to identify GHB-related fatalities. GHB was determined by gas chromatography– mass spectrometry (GC–MS after extraction of the blood and urine in the presence of the internal standard GHB-D6.  The GHB concentration in majority of the blood samples (95% was ≤ 50 mg/L, while in 81% it ranged from 10-50 mg/L. In 95% of the urine samples, the GHB concentration ranged from 10-20 mg/L while 82% of the samples had a concentration of 500 mg/L. The proposed published GHB concentration of 50 mg/L may be used as a cut-off to distinguish between natural endogenous concentrations and exogenous use, but this is not sufficient by itself. The detected GHB concentrations, both in vivo and in postmortem samples, require careful interpretation, not only due to its endogenous nature, but also due to the possibility of postmortem production and also due to its rapid metabolism and excretion.In order to distinguish the endogenous GHB concentration from those reflecting abusive GHB levels, defining a specific cut-off value in biological samples is very crucial. Other matrices, such as vitreous humour, femoral blood and hair must also be considered when interpreting postmortem GHB concentrations.

  14. Measuring Post-Partum Haemorrhage in Low-Resource Settings: The Diagnostic Validity of Weighed Blood Loss versus Quantitative Changes in Hemoglobin.

    Directory of Open Access Journals (Sweden)

    Esther Cathyln Atukunda

    Full Text Available Accurate estimation of blood loss is central to prompt diagnosis and management of post-partum hemorrhage (PPH, which remains a leading cause of maternal mortality in low-resource countries. In such settings, blood loss is often estimated visually and subjectively by attending health workers, due to inconsistent availability of laboratory infrastructure. We evaluated the diagnostic accuracy of weighed blood loss (WBL versus changes in peri-partum hemoglobin to detect PPH.Data from this analysis were collected as part of a randomized controlled trial comparing oxytocin with misoprostol for PPH (NCT01866241. Blood samples for complete blood count were drawn on admission and again prior to hospital discharge or before blood transfusion. During delivery, women were placed on drapes and had pre-weighed sanitary towels placed around their perineum. Blood was then drained into a calibrated container and the sanitary towels were added to estimate WBL, where each gram of blood was estimated as a milliliter. Sensitivity, specificity, negative and positive predictive values (PPVs were calculated at various blood volume loss and time combinations, and we fit receiver-operator curves using blood loss at 1, 2, and 24 hours compared to a reference standard of haemoglobin decrease of >10%.A total of 1,140 women were enrolled in the study, of whom 258 (22.6% developed PPH, defined as a haemoglobin drop >10%, and 262 (23.0% had WBL ≥500mL. WBL generally had a poor sensitivity for detection of PPH (85% in high prevalence settings when WBL exceeds 750mL.WBL has poor sensitivity but high specificity compared to laboratory-based methods of PPH diagnosis. These characteristics correspond to a high PPV in areas with high PPH prevalence. Although WBL is not useful for excluding PPH, this low-cost, simple and reproducible method is promising as a reasonable method to identify significant PPH in such settings where quantifiable red cell indices are unavailable.

  15. Alpha chain hemoglobins with electrophoretic mobility similar to that of hemoglobin S in a newborn screening program

    Directory of Open Access Journals (Sweden)

    Marcilene Rezende Silva

    2013-01-01

    Full Text Available OBJECTIVE: To characterize alpha-chain variant hemoglobins with electric mobility similar to that of hemoglobin S in a newborn screening program. METHODS: βS allele and alpha-thalassemia deletions were investigated in 14 children who had undefined hemoglobin at birth and an electrophoretic profile similar to that of hemoglobin S when they were six months old. Gene sequencing and restriction enzymes (DdeI, BsaJI, NlaIV, Bsu36I and TaqI were used to identify hemoglobins. Clinical and hematological data were obtained from children who attended scheduled medical visits. RESULTS: The following alpha chain variants were found: seven children with hemoglobin Hasharon [alpha2 47(CE5 Asp>His, HbA2:c.142G>C], all associated with alpha-thalassemia, five with hemoglobin Ottawa [alpha1 15(A13 Gly>Arg, HBA1:c.46G>C], one with hemoglobin St Luke's [alpha1 95(G2 Pro>Arg, HBA1:c.287C>G] and another one with hemoglobin Etobicoke [alpha212 84(F5 Ser>Arg, HBA212:c.255C>G]. Two associations with hemoglobin S were found: one with hemoglobin Ottawa and one with hemoglobin St Luke's. The mutation underlying hemoglobin Etobicoke was located in a hybrid α212 allele in one child. There was no evidence of clinically relevant hemoglobins detected in this study. CONCLUSION: Apparently these are the first cases of hemoglobin Ottawa, St Luke's, Etobicoke and the α212 gene described in Brazil. The hemoglobins detected in this study may lead to false diagnosis of sickle cell trait or sickle cell disease when only isoelectric focusing is used in neonatal screening. Additional tests are necessary for the correct identification of hemoglobin variants.

  16. Erythrocyte 2,3-diphosphoglycerate depletion associated with hypophosphatemia detected by routine arterial blood gas analysis.

    Science.gov (United States)

    Larsen, V H; Waldau, T; Gravesen, H; Siggaard-Andersen, O

    1996-01-01

    To describe a clinical case where an extremely low erythrocyte 2,3-diphosphoglycerate concentration (2,3-DPG) was discovered by routine blood gas analysis supplemented by computer calculation of derived quantities. The finding of a low 2,3-DPG revealed a severe hypophosphatemia. Open uncontrolled study of a patient case. Intensive care observation during 41 days. A 44 year old woman with an abdominal abscess. Surgical drainage, antibiotics and parenteral nutrition. daily routine blood gas analyses with computer calculation of the hemoglobin oxygen affinity and estimation of the 2,3-DPG. An abrupt decline of 2,3-DPG was observed late in the course coincident with a pronounced hypophosphatemia. The fall in 2,3-DPG was verified by enzymatic analysis. 2,3-DPG may be estimated by computer calculation of routine blood gas data. A low 2,3-DPG which may be associated with hypophosphatemia causes an unfavorable increase in hemoglobin oxygen affinity which reduces the oxygen release to the tissues.

  17. SMIM1 underlies the Vel blood group and influences red blood cell traits

    DEFF Research Database (Denmark)

    Cvejic, Ana; Haer-Wigman, Lonneke; Stephens, Jonathan C

    2013-01-01

    The blood group Vel was discovered 60 years ago, but the underlying gene is unknown. Individuals negative for the Vel antigen are rare and are required for the safe transfusion of patients with antibodies to Vel. To identify the responsible gene, we sequenced the exomes of five individuals negative...... and expression of the Vel antigen on SMIM1-transfected cells confirm SMIM1 as the gene underlying the Vel blood group. An expression quantitative trait locus (eQTL), the common SNP rs1175550 contributes to variable expression of the Vel antigen (P = 0.003) and influences the mean hemoglobin concentration of red...... blood cells (RBCs; P = 8.6 × 10(-15)). In vivo, zebrafish with smim1 knockdown showed a mild reduction in the number of RBCs, identifying SMIM1 as a new regulator of RBC formation. Our findings are of immediate relevance, as the homozygous presence of the deletion allows the unequivocal identification...

  18. Effect of 2,3-diphosphoglycerate on oxygen affinity of blood in sickle cell anemia

    Science.gov (United States)

    Charache, Samuel; Grisolia, Santiago; Fiedler, Adam J.; Hellegers, Andre E.

    1970-01-01

    Blood of patients with sickle cell anemia (SS) exhibits decreased affinity for oxygen, although the oxygen affinity of hemoglobin S is the same as that of hemoglobin A. SS red cells contain more 2,3-diphosphoglycerate (DPG) than normal erythrocytes. The oxygen affinity of hemolyzed red cells is decreased by added DPG, and hemolysates prepared from SS red cells do not differ from normal hemolysates in this regard. Reduction of oxygen affinity to the levels found in intact SS red cells required DPG concentrations in excess of those found in most SS patients. The same was true of oxygen affinity of patients with pyruvate kinase deficiency. Other organic phosphates, as well as inorganic ions, are known to alter the oxygen affinity of dilute solutions of hemoglobin. These substances, the state of aggregation of hemoglobin molecules, and cytoarchitectural factors probably play roles in determining oxygen affinity of both normal and SS red cells. PMID:5443181

  19. Cancer and Blood Concentrations of the Co-mutagen Harmane in Essential Tremor

    Science.gov (United States)

    Louis, Elan D.; Pellegrino, Kathryn M.; Factor-Litvak, Pam; Rios, Eileen; Jiang, Wendy; Henchcliffe, Claire; Zheng, Wei

    2008-01-01

    Background Blood concentrations of harmane, a tremor-producing neurotoxin, are elevated in essential tremor (ET). Harmane is also a co-mutagen. Objective To compare the prevalence of cancer in ET cases vs. controls, and determine whether blood harmane concentrations are elevated among ET cases with cancer. Methods Case-control design. Results 66/267 (24.7%) ET cases vs. 55/331 (16.6%) controls had cancer (adjusted OR 1.52, 95% CI 1.01 – 2.30, p = 0.04). Among specific cancer types, colon cancer was more prevalent in ET cases than controls (2.6% vs. 0.6%, p = 0.04). Log blood harmane concentration was higher in ET cases vs. controls (p = 0.02) and in participants with vs. without cancer (p = 0.02). Log blood harmane concentration was highest in ET cases with cancer when compared with other groups (p = 0.009). Discussion These links between cancer and ET and between high blood harmane and cancer in ET deserve further study. PMID:18709680

  20. Blood analysis by Raman spectroscopy.

    Science.gov (United States)

    Enejder, Annika M K; Koo, Tae-Woong; Oh, Jeankun; Hunter, Martin; Sasic, Slobodan; Feld, Michael S; Horowitz, Gary L

    2002-11-15

    Concentrations of multiple analytes were simultaneously measured in whole blood with clinical accuracy, without sample processing, using near-infrared Raman spectroscopy. Spectra were acquired with an instrument employing nonimaging optics, designed using Monte Carlo simulations of the influence of light-scattering-absorbing blood cells on the excitation and emission of Raman light in turbid medium. Raman spectra were collected from whole blood drawn from 31 individuals. Quantitative predictions of glucose, urea, total protein, albumin, triglycerides, hematocrit, and hemoglobin were made by means of partial least-squares (PLS) analysis with clinically relevant precision (r(2) values >0.93). The similarity of the features of the PLS calibration spectra to those of the respective analyte spectra illustrates that the predictions are based on molecular information carried by the Raman light. This demonstrates the feasibility of using Raman spectroscopy for quantitative measurements of biomolecular contents in highly light-scattering and absorbing media.

  1. Evaluation of CF/CM, concentration ratios for elements in fetus to mother, using cord blood and maternal blood

    International Nuclear Information System (INIS)

    Watanabe, Y.; Yukawa, M.; Kim, H.S.; Nishimura, Y.; Osada, H.; Sekiya, S.

    2000-01-01

    ICRP recommends age-dependent dose evaluation for intakes of radionuclides by inhalation and ingestion, and gave age-specific biokinetic models and dose coefficients (doses per unit intake) for infants, children and adults in the publications. Dose coefficients are also needed for the assessment of exposures received in utero and after birth by the offspring of the woman who has received intakes of radionuclides. In the model that has been adopted by ICRP, the doses to the developing fetus are calculated using CF/CM values, concentration ratios for radionuclides in the fetus and the maternal tissues. The purpose of this study is to evaluate the CF/CM of each radionuclide by the measurement of element concentration in cord blood and maternal blood. Blood samples were obtained from 35 mothers who delivered in Department of Obstetrics and Gynecology of Chiba University. Just after the delivery, unbiblical cord blood was sampled. Maternal blood was also obtained from the arm vein within 30 minutes after the delivery. The serum was separated from the blood sample with centrifugation. About 50 mg of freezer-dried whole blood and serum were digested with 0.5 ml of 65% ultra-pure nitric acid and 0.2 ml of 30% hydrogen peroxide in a microwave digester. The diluted solutions were used for the determination of elements by ICP-MS (Inductively Coupled Plasma Mass Spectrometry) and ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry). The elements determined in these samples included Mg, K, Ca, Mn, Fe, Cu, Zn, Se, Rb, Sr and Cs. The concentration of Cu was higher in the maternal blood than in the cord blood in both whole blood and serum. On the other hand, Mn and Fe were higher in the cord blood. The differences of concentration ratios among elements and the differences among tissues will be discussed. (author)

  2. Serial changes in plasma K concentration during storage of irradiation blood products

    International Nuclear Information System (INIS)

    Togashi, Kazue; Yamada, Keiko; Otake, Sachiko; Saito, Yukiko; Sugimura, Kazuhito; Takahashi, Hoyu

    1996-01-01

    Irradiation of blood products is highly effective in the prevention of transfusion-associated graft-versus-host disease (GVHD). In order to assess the safe storage period of irradiated blood products, serial changes in plasma K, red cell 2,3-diphosphoglycerate (2,3-DPG) and lactic acid concentrations of whole blood and M·A·P-added red cell concentrate (RC-M·A·P) during storage at 5degC were measured after irradiation with 137 Cs by IBL 437C (CIS bio international). Plasma K concentration did not change immediately after irradiation, but increased more rapidly and in a radiation dose-dependent manner in the irradiated products than nonirradiated products. The changes in red cell 2,3-DPG and lactic acid concentrations were not affected by irradiation but were rather dependent on the storage period after blood collection. Plasma K concentrations of whole blood and RC-M·A·P irradiated with 25 Gy increased at 5 and 3 days, respectively, to the K levels observed after the storage of nonirradiated products for 21 days. It is therefore recommended that whole blood be used within 5 days and RC-M·A·P within 3 days when stored after irradiation with 25 Gy. (author)

  3. Growth stimulation of Porphyromonas endodontalis by hemoglobin and protoporphyrin IX.

    Science.gov (United States)

    Zerr, M A; Cox, C D; Johnson, W T; Drake, D R

    2000-12-01

    Porphyromonas endodontalis, like other Porphyromonas species, has a complex set of nutritional requirements. In addition to being an obligate anaerobe, the bacterium must be grown in a complex medium consisting of amino acids, reducing agents and heme compounds. P. endodontalis accumulates high concentrations of heme pigments to the extent that colonies appear black on blood agar. This accumulation of heme and the need for these compounds has been characterized as iron requirements by these species. However, in our studies, P. endodontalis demonstrated growth dependence on hemoglobin or protoporphyrin IX but not on free iron. Iron added to other heme compounds actually decreased growth stimulation by porphyrin-containing compounds. P. endodontalis actively transported free iron, but this process did not appear to be critical for growth. The maximum stimulation of growth by protoporphyrin IX, under conditions of iron deprivation, suggests that P. endodontalis requires the porphyrin moiety as a growth factor.

  4. The Effects of 6 Isocaloric Meals Pattern on Blood Lipid Profile, Glucose, Hemoglobin A1c, Insulin and Malondialdehyde in Type 2 Diabetic Patients: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Moosa Salehi

    2014-09-01

    Full Text Available Background: The present clinical trial study aims at investigating the effect of daily energy intake in 6 isocaloric meals in comparison with the current meal pattern (3 meals and 2 small snacks per day on type 2 diabetes risk markers in diabetes during 3-month period. Methods: Eighty four type 2 diabetes patients were randomly divided into 6 isocaloric meal diet or a balanced diet (3 meals and 2 snacks previous meal pattern. The planned reduced calorie diets for both groups were identical except for the meal pattern. Blood samples were analyzed before and after the investigation for fasting blood sugar (FBS, two-hour post-prandial glucose (2hPP, insulin, hemoglobin A1c (HbA1c, total cholesterol, triglyceride, HDL-C, LDL-C, and molondialdehyde (MDA concentrations. Results: HbA1c (P=0.00 and body mass index (BMI (P=0.04 values decreased significantly in the 6 isocaloric meal pattern compared with the controls. There were no significant differences in fasting serum glucose (P=0.09, insulin (P=0.65, total cholesterol (P=0.32, LDL-C (P=0.43, HDL-C (P=0.40 cholesterol, triglyceride (P=0.40, MDA (P=0.13 and 2hPP serum glucose (P=0.30 concentrations between the 6 isocaloric meal and tradition meal pattern. Conclusion: Six isocaloric meal pattern in comparison with the current meal pattern led to weight loss and improved glycemic control. Serum lipid profile and MDA did not change significantly. Trial Registration Number: IRCT201205179780N1

  5. Pulsatile Flow and Transport of Blood past a Cylinder: Basic Transport for an Artificial Lung.

    Science.gov (United States)

    Zierenberg, Jennifer R.

    2005-11-01

    The fluid mechanics and transport for flow of blood past a single cylinder is investigated using CFD. This work refers to an artificial lung in which oxygen travels through fibers oriented perpendicularly to the incoming blood flow. A pulsatile blood flow was considered: Ux=U0[ 1+A( φt ) ], where Ux is the velocity far from the cylinder. The Casson equation was used to describe the shear thinning and yield stress properties of blood. The presence of hemoglobin (i.e. facilitated diffusion) was considered. We examined the effect of A, U0 and φ on the flow and transport by varying the dimensionless parameters: A; Reynolds number, Re; and Womersley parameter, α. Two different feed gases were considered: pure O2 and air. The flow and concentration fields were computed for Re = 5, 10, and 40, 0 transport is found to primarily depend on Re and to increase with increasing Re, α and decreasing A. The presence of hemoglobin increases mass transport. Supported by NIH HL69420, NSF Fellowship

  6. The Chronic and Acute Effects of Exercise Upon Selected Blood Measures.

    Science.gov (United States)

    Roitman, J. L.; Brewer, J. P.

    This study investigated the effects of chronic and acute exercise upon selected blood measures and indices. Nine male cross-country runners were studied. Red blood count, hemoglobin, and hematocrit were measured using standard laboratory techniques; mean corpuscular volume (MCV), mean corpuscular hemoglobin, and mean corpuscular hemoglobin…

  7. Hemoglobin Wayne Trait with Incidental Polycythemia.

    Science.gov (United States)

    Ambelil, Manju; Nguyen, Nghia; Dasgupta, Amitava; Risin, Semyon; Wahed, Amer

    2017-01-01

    Hemoglobinopathies, caused by mutations in the globin genes, are one of the most common inherited disorders. Many of the hemoglobin variants can be identified by hemoglobin analysis using conventional electrophoresis and high performance liquid chromatography; however hemoglobin DNA analysis may be necessary in other cases for confirmation. Here, we report a case of a rare alpha chain hemoglobin variant, hemoglobin Wayne, in a 47-year-old man who presented with secondary polycythemia. Capillary zone electrophoresis and high performance liquid chromatography revealed a significant amount of a hemoglobin variant, which was further confirmed by hemoglobin DNA sequencing as hemoglobin Wayne. Since the patient was not homozygous for hemoglobin Wayne, which is associated with secondary polycythemia, the laboratory diagnosis in this case was critical in ruling out hemoglobinopathy as the etiology of his polycythemia. © 2017 by the Association of Clinical Scientists, Inc.

  8. HEMOGLOBIN AND HEMATOCRITE CHANGES DURING UNCOMPLICATED ANESTHESIA: GENERAL ANESTHESIA AND LOCAL ANESTHESIA

    Directory of Open Access Journals (Sweden)

    KH NAGHIBI

    2002-12-01

    Full Text Available Introduction. Despite of vital role of blood and it"s components as an only curable treatment, it"s transfusion is accompanied by many complications. In the other way, the most important adverse effects of anemia is decrease in oxygen supply to the tissues. Therefore, it is essential to determine those patients need to blood transfusion and exact hemoglobine and hematocrite level which transfusion become necessary. Recent studies show that during general anesthesia due to vasodilation in the level of microcirculation and passage of many red blood cells from microcirculation there is a decreasing in hemoglobine level measured in peripheral veins which named plasma skimming. So, during sampling of hemoglobine and hematocrite from peripheral veins, there is a pseudodecrease in Hb and HCT levels. In this study we want to determine this decrease in Hb and HeT. Methods. Study was done in 182 patients with ASA 1 and 2 undergoing general or local anesthesia for cataract surgery. Duration of nill per os (NPO, preoperotive and intraoperative intravenous fluid administration were simillar in two groups. A sample of blood for preoperative evaluation and another one immediately after operation achevied and compared with each other. Results. There was not significant differences between mean Hb and HCT in two groups preoperotive. But postoperative, there was a significant differences between mean Hb and HCT in general anesthesia vs local anesthesia (P < 0.01. This decrease in Hb and HCT was orderly 0.91 ± 1.14 gr/dl for Hb and 2.862±3.6 percent for Hct. Discussion. In determining of Hb and HCT immediately after general anesthesia, there is some pseudo decrease due to plasma skimming that must be appreciated.

  9. The Hemoglobin E Thalassemias

    Science.gov (United States)

    Fucharoen, Suthat; Weatherall, David J.

    2012-01-01

    Hemoglobin E (HbE) is an extremely common structural hemoglobin variant that occurs at high frequencies throughout many Asian countries. It is a β-hemoglobin variant, which is produced at a slightly reduced rate and hence has the phenotype of a mild form of β thalassemia. Its interactions with different forms of α thalassemia result in a wide variety of clinical disorders, whereas its coinheritance with β thalassemia, a condition called hemoglobin E β thalassemia, is by far the most common severe form of β thalassemia in Asia and, globally, comprises approximately 50% of the clinically severe β-thalassemia disorders. PMID:22908199

  10. Prediction of hemoglobin levels in whole blood donors: how to model donation history

    NARCIS (Netherlands)

    Baart, A.M.; Vergouwe, Y.; Atsma, F.; Moons, K.G.; Kort, W.L. de

    2014-01-01

    BACKGROUND: Recently, prediction models for hemoglobin (Hb) deferral risk have been developed. These models consider the previous Hb level plus change in Hb. Here, we investigated if the performance of models could be improved by considering more information on Hb level history. STUDY DESIGN AND

  11. Moessbauer and positron annihilation studies of structural modifications of hemoglobin in solution

    International Nuclear Information System (INIS)

    Oshtrakh, M.I.; Kopelyan, E.A.; Semionkin, V.A.

    1995-01-01

    Structural modifications of human adult oxyhemoglobin in concentrated solution were studied by Moessbauer and positron life-time spectroscopies. The effects of non-sterile degradation and irradiation by γ-rays were compared by both techniques. It was found that positron annihilation parameters were sensitive to the structural modifications of hemoglobin molecules in solution and could be related with the conformational states of hemoglobin. (author)15 refs.; 3 tabs

  12. Performance IQ in children is associated with blood cadmium concentration in early pregnancy.

    Science.gov (United States)

    Jeong, Kyoung Sook; Park, Hyewon; Ha, Eunhee; Hong, Yun-Chul; Ha, Mina; Park, Hyesook; Kim, Bung-Nyun; Lee, Bo-Eun; Lee, Soo-Jeong; Lee, Kyung Yeon; Kim, Ja Hyeong; Kim, Yangho

    2015-04-01

    To investigate whether performance IQ in children is associated with maternal blood cadmium concentration in early pregnancy. The present study is a component of the Mothers' and Children's Environmental Health (MOCEH) study, a multi-center birth cohort project in Korea that began in 2006. The study cohort consisted of 119 children whose mothers underwent testing of blood cadmium during early pregnancy. All children were evaluated using the Korean version of the Wechsler Preschool and Primary Scale of Intelligence, revised edition (WPPSI-R), at 60 months of age. Multivariate linear regression analysis was performed to analyze the correlation between IQ in children and maternal blood cadmium concentration in early pregnancy, after adjustment for covariates. Maternal blood cadmium concentration during early pregnancy was inversely associated with performance IQ, after adjustment for covariates such as sex, educational levels of both parents, family income, and maternal BMI. Maternal blood cadmium concentration, however, was not associated with cognitive IQ. Performance IQ in children is associated with maternal blood cadmium concentration in early pregnancy. Copyright © 2014 Elsevier GmbH. All rights reserved.

  13. Novel idea to monitor and measure blood hemoglobin noninvasively ...

    African Journals Online (AJOL)

    Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined.

  14. Enhancement of Salinity Tolerance during Rice Seed Germination by Presoaking with Hemoglobin

    Directory of Open Access Journals (Sweden)

    Sheng Xu

    2011-04-01

    Full Text Available Salinity stress is an important environmental constraint limiting the productivity of many crops worldwide. In this report, experiments were conducted to investigate the effects of seed presoaking by bovine hemoglobin, an inducer of heme oxygenase-1 (HO-1, on salinity tolerance in rice (Oryza sativa plants. The results showed that different concentrations of the hemoglobin (0.01, 0.05, 0.2, 1.0, and 5.0 g/L differentially alleviated the inhibition of rice seed germination and thereafter seedling shoot growth caused by 100 mM NaCl stress, and the responses of 1.0 g/L hemoglobin was the most obvious. Further analyses showed that application of hemoglobin not only increased the HO-1 gene expression, but also differentially induced catalase (CAT, ascorbate peroxidase (APX, and superoxide dismutase (SOD activities or transcripts, thus decreasing the lipid peroxidation in germinating rice seeds subjected to salt stress. Compared with non-hemoglobin treatment, hemoglobin presoaking also increased the potassium (K to sodium (Na ratio both in the root and shoot parts after salinity stress. The effect is specific for HO-1 since the potent HO-1 inhibitor zinc protoporphyrin IX (ZnPPIX blocked the positive actions of hemoglobin on seed germination and seedling shoot growth. Overall, these results suggested that hemoglobin performs an advantageous role in enhancement of salinity tolerance during rice seed germination.

  15. Serum-free Erythroid Differentiation for Efficient Genetic Modification and High-Level Adult Hemoglobin Production.

    Science.gov (United States)

    Uchida, Naoya; Demirci, Selami; Haro-Mora, Juan J; Fujita, Atsushi; Raines, Lydia N; Hsieh, Matthew M; Tisdale, John F

    2018-06-15

    In vitro erythroid differentiation from primary human cells is valuable to develop genetic strategies for hemoglobin disorders. However, current erythroid differentiation methods are encumbered by modest transduction rates and high baseline fetal hemoglobin production. In this study, we sought to improve both genetic modification and hemoglobin production among human erythroid cells in vitro . To model therapeutic strategies, we transduced human CD34 + cells and peripheral blood mononuclear cells (PBMCs) with lentiviral vectors and compared erythropoietin-based erythroid differentiation using fetal-bovine-serum-containing media and serum-free media. We observed more efficient transduction (85%-93%) in serum-free media than serum-containing media (20%-69%), whereas the addition of knockout serum replacement (KSR) was required for serum-free media to promote efficient erythroid differentiation (96%). High-level adult hemoglobin production detectable by electrophoresis was achieved using serum-free media similar to serum-containing media. Importantly, low fetal hemoglobin production was observed in the optimized serum-free media. Using KSR-containing, serum-free erythroid differentiation media, therapeutic adult hemoglobin production was detected at protein levels with β-globin lentiviral transduction in both CD34 + cells and PBMCs from sickle cell disease subjects. Our in vitro erythroid differentiation system provides a practical evaluation platform for adult hemoglobin production among human erythroid cells following genetic manipulation.

  16. Resting blood lactate in individuals with sickle cell disease

    Science.gov (United States)

    Petto, Jefferson; de Jesus, Jaqueline Brito; Vasques, Leila Monique Reis; Pinheiro, Renata Leão Silva; Oliveira, Aila Mascarenhas; Spinola, Kelly Aparecida Borges; Silva, Wellington dos Santos

    2011-01-01

    Background The most common hereditary hemoglobin disorder, affecting 20 million individuals worldwide, is sickle cell disease. The vascular obstruction resulting from the sickling of cells in this disease can produce local hypoxemia, pain crises and infarction in several tissues, including the bones, spleen, kidneys and lungs. Objective To determine red blood group genes in a Brazilian populations. Methods The present study is characterized as a case control study, with the aim of identifying the baseline blood lactate concentration in individuals with hemoglobin SS and SC diseases. One-way ANOVA with the Tukey post-test was used to analyze the results and a p-value < 0.05 was considered significant. Calculations were made using the INSTAT statistical program. The graphs were generated using the ORING program. The study sample was composed of 31 men and women residing in the city of Santo Antônio de Jesus, Bahia, Brazil. The individuals were divided into two groups: Group GC of 16 subjects who did not present with any type of structural hemoglobinopathy; and Group GE composed of 15 individuals with ages between 2 and 35 years old, who had the SS and SC genotypes. Sample analyses were performed with 3 mL of blood during fasting. Results The baseline blood lactate concentration of the SS and SC individuals was higher than that of the control group (p<0.001) with means of 4.86 ± 0.95; 3.30 ± 0.33; 1.31 ± 0.08 IU/L for SS, SC and controls, respectively. This corroborates the initial research hypothesis. Conclusion The baseline blood lactate of SS and SC individuals is 3 to 4 times higher than that of healthy subjects, probably due to the fact that these patients have a metabolic deviation to the anaerobic pathway. PMID:23284239

  17. Carbon monoxide and COHb concentration in blood in various circumstances

    Energy Technology Data Exchange (ETDEWEB)

    Modic, J. [Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana (Slovenia)

    2003-07-01

    On the basis of known medical experiments we find out the correlation between the concentration of carbon monoxide (CO) in inhaling air and the concentration of carboxihemoglobyne (COHb) in human blood. All internal combustion engines produce exhaust gases containing noxious compounds: carbon monoxide, nitrogen oxides (NO{sub x}), carbon oxides (CxHy) and smoke. In a living room is important the smoke of cigarettes, smoke of furnaces, improper ventilation. In tunnel is most dangerous the carbon monoxide if it exceeds an allowable level. In human blood the carbon monoxide causes increasing the concentration of carboxihemoglobyne and in this case the hypoxia of web. With help of mathematical model the concentrations of some dangerous substances at the end of tunnel were calculated. For this case a differential equation also was developed and it shows the correlation between concentration of carbon monoxide in the air and concentration of carboxihemoglobyne in the blood. The constructed mathematical model shows circumstances in the tunnel (velocity of air moving as effect of induction, concentration of noxious substances and criterial number). Also a corresponding computer program was developed, which makes possible a quick and simple calculation. All the results are proved by experiments. Finally the differential equation was done, which shows a temporal connection between both parameters as a function of tunnel characteristics. (author)

  18. Further investigations on the influence of ultraviolet irradiation on blood corpuscles hemoglobin content and differential leucocyte count in the chicken

    International Nuclear Information System (INIS)

    Bolukbasi, F.

    1978-01-01

    The influence of ultraviolet irradiation, applied for one hour, with a relatively high enerqy output of 95.5x10 3 erg. cm -2 . sn -1 , on some biological parameters of chicken's blood was determined. At the 24th hour after irradiation erythrocyte count, hemoglobin content and percentages of lymphocytes, monocytes, eosinophils and basophils were decreased, but total leucocyte, thrombocyte counts and percentage of pseudoeosinophils were increased, significantly (P< 0,01). No significant changes were obtained in all parameters, at the 24th hour after a second irradiation. There were also found no differences between the values obtained at 24th hour after the second, and at 48th hour after the single irradiation, but all these values had a tendency taward the initial determinations

  19. Evaluation and additional recommendations for preparing a whole blood control material

    Directory of Open Access Journals (Sweden)

    Nilda E. Fink

    1998-04-01

    Full Text Available OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation was: white blood cells (WBC 2.7, red blood cells (RBC 0.7, hemoglobin (Hb 0.6, hematocrit (Hct 0.7, mean cell volume (MCV 0.3, mean cell hemoglobin (MCH 0.6, mean cell hemoglobin concentration (MCHC 0.7, and platelets (PLT 4.6. The CV (coefficient of variation percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes. CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.

  20. Efficacy of tranexamic acid in reducing blood loss in posterior lumbar spine surgery for degenerative spinal stenosis with instability: a retrospective case control study

    Directory of Open Access Journals (Sweden)

    Endres Stefan

    2011-11-01

    Full Text Available Abstract Background Degenerative spinal stenosis and instability requiring multilevel spine surgery has been associated with large blood losses. Factors that affect perioperative blood loss include time of surgery, surgical procedure, patient height, combined anterior/posterior approaches, number of levels fused, blood salvage techniques, and the use of anti-fibrinolytic medications. This study was done to evaluate the efficacy of tranexamic acid in reducing blood loss in spine surgery. Methods This retrospective case control study includes 97 patients who had to undergo surgery because of degenerative lumbar spinal stenosis and instability. All operations included spinal decompression, interbody fusion and posterior instrumentation (4-5 segments. Forty-six patients received 1 g tranexamic acid intravenous, preoperative and six hours and twelve hours postoperative; 51 patients without tranexamic acid administration were evaluated as a control group. Based on the records, the intra- and postoperative blood losses were measured by evaluating the drainage and cell saver systems 6, 12 and 24 hours post operation. Additionally, hemoglobin concentration and platelet concentration were reviewed. Furthermore, the number of red cell transfusions given and complications associated with tranexamic acid were assessed. Results The postoperative hemoglobin concentration demonstrated a statistically significant difference with a p value of 0.0130 showing superiority for tranexamic acid use (tranexamic acid group: 11.08 g/dl, SD: 1.68; control group: 10.29 g/dl, SD: 1.39. The intraoperative cell saver volume and drainage volume after 24 h demonstrated a significant difference as well, which indicates a less blood loss in the tranexamic acid group than the control group. The postoperative drainage volume at12 hours showed no significant differences; nor did the platelet concentration Allogenic blood transfusion (two red cell units was needed for eight patients

  1. Plasma free hemoglobin and microcirculatory response to fresh or old blood transfusions in sepsis.

    Directory of Open Access Journals (Sweden)

    Elisa Damiani

    Full Text Available Free hemoglobin (fHb may induce vasoconstriction by scavenging nitric oxide. It may increase in older blood units due to storage lesions. This study evaluated whether old red blood cell transfusion increases plasma fHb in sepsis and how the microvascular response may be affected.This is a secondary analysis of a randomized study. Twenty adult septic patients received either fresh or old (15 days storage, respectively RBC transfusions. fHb was measured in RBC units and in the plasma before and 1 hour after transfusion. Simultaneously, the sublingual microcirculation was assessed with sidestream-dark field imaging. The perfused boundary region was calculated as an index of glycocalyx damage. Tissue oxygen saturation (StO2 and Hb index (THI were measured with near-infrared spectroscopy and a vascular occlusion test was performed.Similar fHb levels were found in the supernatant of fresh and old RBC units. Despite this, plasma fHb increased in the old RBC group after transfusion (from 0.125 [0.098-0.219] mg/mL to 0.238 [0.163-0.369] mg/mL, p = 0.006. The sublingual microcirculation was unaltered in both groups, while THI increased. The change in plasma fHb was inversely correlated with the changes in total vessel density (r = -0.57 [95% confidence interval -0.82, -0.16], p = 0.008, De Backer score (r = -0.63 [95% confidence interval -0.84, -0.25], p = 0.003 and THI (r = -0.72 [95% confidence interval -0.88, -0.39], p = 0.0003.Old RBC transfusion was associated with an increase in plasma fHb in septic patients. Increasing plasma fHb levels were associated with decreased microvascular density.ClinicalTrials.gov NCT01584999.

  2. Evaluation of a next generation direct whole blood enzymatic assay for hemoglobin A1c on the ARCHITECT c8000 chemistry system.

    Science.gov (United States)

    Teodoro-Morrison, Tracy; Janssen, Marcel J W; Mols, Jasper; Hendrickx, Ben H E; Velmans, Mathieu H; Lotz, Johannes; Lackner, Karl; Lennartz, Lieselotte; Armbruster, David; Maine, Gregory; Yip, Paul M

    2015-01-01

    The utility of HbA1c for the diagnosis of type 2 diabetes requires an accurate, precise and robust test measurement system. Currently, immunoassay and HPLC are the most popular methods for HbA1c quantification, noting however the limitations associated with some platforms, such as imprecision or interference from common hemoglobin variants. Abbott Diagnostics has introduced a fully automated direct enzymatic method for the quantification of HbA1c from whole blood on the ARCHITECT chemistry system. Here we completed a method evaluation of the ARCHITECT HbA1c enzymatic assay for imprecision, accuracy, method comparison, interference from hemoglobin variants and specimen stability. This was completed at three independent clinical laboratories in North America and Europe. The total imprecision ranged from 0.5% to 2.2% CV with low and high level control materials. Around the diagnostic cut-off of 48 mmol/mol, the total imprecision was 0.6% CV. Mean bias using reference samples from IFCC and CAP ranged from -1.1 to 1.0 mmol/mol. The enzymatic assay also showed excellent agreement with HPLC methods, with slopes of 1.01 and correlation coefficients ranging from 0.984 to 0.996 compared to Menarini Adams HA-8160, Bio-Rad Variant II and Variant II Turbo instruments. Finally, no significant effect was observed for erythrocyte sedimentation or interference from common hemoglobin variants in patient samples containing heterozygous HbS, HbC, HbD, HbE, and up to 10% HbF. The ARCHITECT enzymatic assay for HbA1c is a robust and fully automated method that meets the performance requirements to support the diagnosis of type 2 diabetes.

  3. The Effects of Blood Transfusion on Delirium Incidence.

    Science.gov (United States)

    van der Zanden, Vera; Beishuizen, Sara J; Scholtens, Rikie M; de Jonghe, Annemarieke; de Rooij, Sophia E; van Munster, Barbara C

    2016-08-01

    Both anemia and blood transfusion could be precipitating factors for delirium; hence in postoperative patients with anemia at high risk for delirium, it is controversial whether transfusion is the best option. The aim of this study is to investigate the association of anemia and delirium and the role of blood transfusion within the multicomponent prevention strategy of delirium. We conducted a substudy of a multicenter randomized controlled trial. Four hundred fifteen patients aged 65 to 102 years old admitted for hip fracture surgery were enrolled. Delirium was assessed daily using criteria of the Diagnostic and Statistical Manual of Mental Disorders, fourth edition. Data on hemoglobin values and transfusion were collected from the electronic medical records. One hundred fifteen (32.5%) patients experienced delirium during hospitalization, 238 (57.5%) had a hemoglobin level ≤ 6.0 mmol/L (9.7 g/dL) at any time during hospitalization, and 140 (33.7%) received a blood transfusion. Anemia (a hemoglobin level ≤ 6.0 mmol/L [9.7 g/dL]) was associated with delirium (odds ratio, 1.81; 95% confidence interval, 1.15-2.86). Blood transfusion was a protective factor for delirium in patients with the lowest measured hemoglobin level ≤ 6.0 mmol/L (9.7 g/dL) (odds ratio, 0.26; 95% confidence interval, 0.10-0.70). Low hemoglobin level is associated with delirium, and receiving a blood transfusion is associated with a lower delirium incidence. It would be interesting to investigate the effect of blood transfusion as part of the multicomponent treatment of delirium in patients with anemia. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  4. Phylogeny of Echinoderm Hemoglobins.

    Directory of Open Access Journals (Sweden)

    Ana B Christensen

    Full Text Available Recent genomic information has revealed that neuroglobin and cytoglobin are the two principal lineages of vertebrate hemoglobins, with the latter encompassing the familiar myoglobin and α-globin/β-globin tetramer hemoglobin, and several minor groups. In contrast, very little is known about hemoglobins in echinoderms, a phylum of exclusively marine organisms closely related to vertebrates, beyond the presence of coelomic hemoglobins in sea cucumbers and brittle stars. We identified about 50 hemoglobins in sea urchin, starfish and sea cucumber genomes and transcriptomes, and used Bayesian inference to carry out a molecular phylogenetic analysis of their relationship to vertebrate sequences, specifically, to assess the hypothesis that the neuroglobin and cytoglobin lineages are also present in echinoderms.The genome of the sea urchin Strongylocentrotus purpuratus encodes several hemoglobins, including a unique chimeric 14-domain globin, 2 androglobin isoforms and a unique single androglobin domain protein. Other strongylocentrotid genomes appear to have similar repertoires of globin genes. We carried out molecular phylogenetic analyses of 52 hemoglobins identified in sea urchin, brittle star and sea cucumber genomes and transcriptomes, using different multiple sequence alignment methods coupled with Bayesian and maximum likelihood approaches. The results demonstrate that there are two major globin lineages in echinoderms, which are related to the vertebrate neuroglobin and cytoglobin lineages. Furthermore, the brittle star and sea cucumber coelomic hemoglobins appear to have evolved independently from the cytoglobin lineage, similar to the evolution of erythroid oxygen binding globins in cyclostomes and vertebrates.The presence of echinoderm globins related to the vertebrate neuroglobin and cytoglobin lineages suggests that the split between neuroglobins and cytoglobins occurred in the deuterostome ancestor shared by echinoderms and vertebrates.

  5. [Full blood count reference values in children of 8 to 12 years old residing at 2,760 m above sea level].

    Science.gov (United States)

    Armando García-Miranda, L; Contreras, I; Estrada, J A

    2014-04-01

    To determine reference values for full blood count parameters in a population of children 8 to 12 years old, living at an altitude of 2760 m above sea level. Our sample consisted of 102 individuals on whom a full blood count was performed. The parameters included: total number of red blood cells, platelets, white cells, and a differential count (millions/μl and %) of neutrophils, lymphocytes, monocytes, eosinophils and basophils. Additionally, we obtained values for hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin, concentration of corpuscular hemoglobin and red blood cell distribution width. The results were statistically analyzed with a non-parametric test, to divide the sample in quartiles and obtain the lower and upper limits for our intervals. Moreover, the values for the intervals obtained from this analysis were compared to intervals obtained estimating+- 2 standard deviations above and below from our mean values. Our results showed significant differences compared to normal interval values reported for the adult Mexican population in most of the parameters studied. The full blood count is an important laboratory test used routinely for the initial assessment of a patient. Values of full blood counts in healthy individuals vary according to gender, age and geographic location; therefore, each population should have its own reference values. Copyright © 2013 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  6. Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography

    Science.gov (United States)

    Boverman, Gregory; Fang, Qianqian; Carp, Stefan A.; Miller, Eric L.; Brooks, Dana H.; Selb, Juliette; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.

    2007-07-01

    We develop algorithms for imaging the time-varying optical absorption within the breast given diffuse optical tomographic data collected over a time span that is long compared to the dynamics of the medium. Multispectral measurements allow for the determination of the time-varying total hemoglobin concentration and of oxygen saturation. To facilitate the image reconstruction, we decompose the hemodynamics in time into a linear combination of spatio-temporal basis functions, the coefficients of which are estimated using all of the data simultaneously, making use of a Newton-based nonlinear optimization algorithm. The solution of the extremely large least-squares problem which arises in computing the Newton update is obtained iteratively using the LSQR algorithm. A Laplacian spatial regularization operator is applied, and, in addition, we make use of temporal regularization which tends to encourage similarity between the images of the spatio-temporal coefficients. Results are shown for an extensive simulation, in which we are able to image and quantify localized changes in both total hemoglobin concentration and oxygen saturation. Finally, a breast compression study has been performed for a normal breast cancer screening subject, using an instrument which allows for highly accurate co-registration of multispectral diffuse optical measurements with an x-ray tomosynthesis image of the breast. We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast.

  7. Measurements of red cell deformability and hydration reflect HbF and HbA2 in blood from patients with sickle cell anemia.

    Science.gov (United States)

    Parrow, Nermi L; Tu, Hongbin; Nichols, James; Violet, Pierre-Christian; Pittman, Corinne A; Fitzhugh, Courtney; Fleming, Robert E; Mohandas, Narla; Tisdale, John F; Levine, Mark

    2017-06-01

    Decreased erythrocyte deformability, as measured by ektacytometry, may be associated with disease severity in sickle cell anemia (SCA). Heterogeneous populations of rigid and deformable cells in SCA blood result in distortions of diffraction pattern measurements that correlate with the concentration of hemoglobin S (HbS) and the percentage of irreversibly sickled cells. We hypothesize that red cell heterogeneity, as well as deformability, will also be influenced by the concentration of alternative hemoglobins such as fetal hemoglobin (HbF) and the adult variant, HbA 2 . To test this hypothesis, we investigate the relationship between diffraction pattern distortion, osmotic gradient ektacytometry parameters, and the hemoglobin composition of SCA blood. We observe a correlation between the extent of diffraction pattern distortions and percentage of HbF and HbA 2 . Osmotic gradient ektacytometry data indicate that minimum elongation in the hypotonic region is positively correlated with HbF, as is the osmolality at which it occurs. The osmolality at both minimum and maximum elongation is inversely correlated with HbS and HbA 2 . These data suggest that HbF may effectively improve surface-to-volume ratio and osmotic fragility in SCA erythrocytes. HbA 2 may be relatively ineffective in improving these characteristics or cellular hydration at the levels found in this patient cohort. Copyright © 2017. Published by Elsevier Inc.

  8. Reference Brain/Blood Concentrations of Citalopram, Duloxetine, Mirtazapine and Sertraline

    DEFF Research Database (Denmark)

    Nedahl, Michael; Johansen, Sys Stybe; Linnet, Kristian

    2018-01-01

    Postmortem blood samples may not accurately reflect antemortem drug concentrations, as the levels of some drugs increase due to postmortem redistribution (PMR). The brain has been suggested as an alternative sampling site. The anatomically secluded site of the brain limits redistribution and prol.......85), whereas the median citalopram/N-desmethylcitalopram ratio was higher in brain (9.1) than blood (4.1). The results of this study may serve as reference concentrations in brain for forensic cases....

  9. Hemoglobin adducts in workers exposed to 1,6-hexamethylene diisocyanate.

    Science.gov (United States)

    Flack, Sheila L; Fent, Kenneth W; Gaines, Linda G T; Thomasen, Jennifer M; Whittaker, Stephen G; Ball, Louise M; Nylander-French, Leena A

    2011-05-01

    We investigated the utility of 1,6-hexamethylene diamine (HDA) hemoglobin adducts as biomarkers of exposure to 1,6-hexamethylene diisocyanate (HDI) monomer. Blood samples from 15 spray painters applying HDI-containing paint were analyzed for hemoglobin HDA (HDA-Hb) and N-acetyl-1,6-hexamethylene diamine (monoacetyl-HDA-Hb) by GC-MS. HDA-Hb was detected in the majority of workers (≤1.2-37 ng/g Hb), whereas monoacetyl-HDA-Hb was detected in one worker (0.06 ng/g Hb). The stronger, positive association between HDA-Hb and cumulative HDI exposure (r(2) = 0.3, p HDA-Hb adducts. This association demonstrates the suitability of HDA-Hb adducts for further validation as a biomarker of HDI exposure.

  10. The effect of climbing Mount Everest on spleen contraction and increase in hemoglobin concentration during breath holding and exercise.

    Science.gov (United States)

    Engan, Harald K; Lodin-Sundström, Angelica; Schagatay, Fanny; Schagatay, Erika

    2014-04-01

    Release of stored red blood cells resulting from spleen contraction improves human performance in various hypoxic situations. This study determined spleen volume resulting from two contraction-evoking stimuli: breath holding and exercise before and after altitude acclimatization during a Mount Everest ascent (8848 m). Eight climbers performed the following protocol before and after the climb: 5 min ambient air respiration at 1370 m during rest, 20 min oxygen respiration, 20 min ambient air respiration at 1370 m, three maximal-effort breath holds spaced by 2 min, 10 min ambient air respiration, 5 min of cycling at 100 W, and finally 10 min ambient air respiration. We measured spleen volume by ultrasound and capillary hemoglobin (HB) concentration after each exposure, and heart rate (HR) and arterial oxygen saturation (Sao2) continuously. Mean (SD) baseline spleen volume was unchanged at 213 (101) mL before and 206 (52) mL after the climb. Before the climb, spleen volume was reduced to 184 (83) mL after three breath holds, and after the climb three breath holds resulted in a spleen volume of 132 (26) mL (p=0.032). After exercise, the preclimb spleen volume was 186 (89) mL vs. 112 (389) mL) after the climb (p=0.003). Breath hold duration and cardiovascular responses were unchanged after the climb. We concluded that spleen contraction may be enhanced by altitude acclimatization, probably reflecting both the acclimatization to chronic hypoxic exposure and acute hypoxia during physical work.

  11. Relation between serum lipoperoxide concentrations and iron or copper status over one year in Cuban adult men

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, J.; Renversez, J.C.; Favier, A.E. [Dept. de Biologie Integree, CHUG, Grenoble (France); Fleites, P.; Perez-Cristia, R. [Centro national de Toxicologia (CENATOX), La Habana (Cuba); Chassagne, M.; Barnouin, J. [INRA, Unite d' Ecopathologie, Saint Genes Champanelle (France); Verdura, T. [Inst. Finlay, La Lisa, La Habana (Cuba); Garcia, I.G. [Inst. de Farmacia y Alimentos, La Coronela, La Lisa, Ciudad de la Habana (Cuba); Tressol, J.C. [INRA, Unite maladies metaboliques et micronutriments, Saint Genes Champanelle (France)

    2001-07-01

    The aims of this study were to determine the relations between iron and copper status and lipid peroxidation at different periods over one year in low-income and low-energy intake healthy subjects. The study was conducted in 199 middle-aged healthy Cuban men from March 1995 to February 1996. Iron status was assessed by the determination of serum ferritin, transferrin saturation, whole blood hemoglobin and iron intakes. Copper status was evaluated by the determination of serum copper and copper intakes. Serum thiobarbituric acid substances (TBARS) determination was used as an index of lipid peroxidation. Rank correlations were observed between serum TBARS concentrations and iron or copper status indices at different periods. In period 3 (end of the rainy season), serum TBARS and ferritin concentrations were maximum whereas blood hemoglobin levels and iron intake were minimum. Serum TBARS concentrations were significantly higher than the reference values of the laboratory whereas, iron and copper status were within the reference ranges. These results suggested that iron and copper status may be associated with lipid peroxidation in subjects without metal overloads and that variations over the year needed to be taken in account. (orig.)

  12. Serum heavy metals and hemoglobin related compounds in Saudi Arabia firefighters

    Directory of Open Access Journals (Sweden)

    Al-Malki Abdulrahman L

    2009-07-01

    Full Text Available Abstract Background Firefighters are frequently exposed to significant concentrations of hazardous materials including heavy metals, aldehydes, hydrogen chloride, dichlorofluoromethane and some particulates. Many of these materials have been implicated in the triggering of several diseases. The aim of the present study is to investigate the effect of fire smoke exposure on serum heavy metals and possible affection on iron functions compounds (total iron binding capacity, transferrin saturation percent, ferritin, unsaturated iron-binding capacity blood hemoglobin and carboxyhemoglobin,. Subjects and methods Two groups of male firefighter volunteers were included; the first included 28 firefighters from Jeddah city, while the second included 21 firefighters from Yanbu city with an overall age rang of 20–48 years. An additional group of 23 male non-firefighters volunteered from both cities as normal control subjects. Blood samples were collected from all volunteer subjects and investigated for relevant parameters. Results The results obtained showed that there were no statistically significant changes in the levels of serum heavy metals in firefighters as compared to normal control subjects. Blood carboxyhemoglobin and serum ferritin were statistically increased in Jeddah firefighters, (p Conclusion Such results might point to the need for more health protective and prophylactic measures to avoid such hazardous health effects (elevated Blood carboxyhemoglobin and serum ferritin and decreased serum TIBC and UIBC that might endanger firefighters working under dangerous conditions. Firefighters must be under regular medical follow-up through standard timetabled medical laboratory investigations to allow for early detection of any serum biochemical or blood hematological changes.

  13. Fish hemoglobins

    OpenAIRE

    Souza,P.C. de; Bonilla-Rodriguez,G.O.

    2007-01-01

    Vertebrate hemoglobin, contained in erythrocytes, is a globular protein with a quaternary structure composed of 4 globin chains (2 alpha and 2 beta) and a prosthetic group named heme bound to each one. Having myoglobin as an ancestor, hemoglobin acquired the capacity to respond to chemical stimuli that modulate its function according to tissue requirements for oxygen. Fish are generally submitted to spatial and temporal O2 variations and have developed anatomical, physiological and biochemica...

  14. Point of care hematocrit and hemoglobin in cardiac surgery: a review.

    Science.gov (United States)

    Myers, Gerard J; Browne, Joe

    2007-05-01

    The use of point-of-care blood gas analyzers in cardiac surgery has been on the increase over the past decade. The availability of these analyzers in the operating room and post-operative intensive care units eliminates the time delays to transport samples to the main laboratory and reduces the amount of blood sampled to measure such parameters as electrolytes, blood gases, lactates, glucose and hemoglobin/hematocrit. Point-of-care analyzers also lead to faster and more reliable clinical decisions while the patient is still on the heart lung machine. Point-of-care devices were designed to provide safe, appropriate and consistent care of those patients in need of rapid acid/base balance and electrolyte management in the clinical setting. As a result, clinicians rely on their values to make decisions regarding ventilation, acid/base management, transfusion and glucose management. Therefore, accuracy and reliability are an absolute must for these bedside analyzers in both the cardiac operating room and the post-op intensive care units. Clinicians have a choice of two types of technology to measure hemoglobin/hematocrit during bypass, which subsequently determines their patient's level of hemodilution, as well as their transfusion threshold. All modern point-of-care blood gas analyzers measure hematocrit using a technology called conductivity, while other similar devices measure hemoglobin using a technology called co-oximetry. The two methods are analyzed and compared in this review. The literature indicates that using conductivity to measure hematocrit during and after cardiac surgery could produce inaccurate results when hematocrits are less than 30%, and, therefore, result in unnecessary homologous red cell transfusions in some patients. These inaccuracies are influenced by several factors that are common and unique to cardiopulmonary bypass, and will also be reviewed here. It appears that the only accurate, consistent and reliable method to determine hemodilution

  15. Hemoglobin and hematocrit at the end of hemodialysis: a better way to adjust erythropoietin dose?

    Science.gov (United States)

    Rangel, Erika B; Andreoli, Maria Claudia; Matos, Ana Cristina C; Guimarães-Souza, Nadia K; Mallet, Ana Cláudia; Carneiro, Fabiana D; Santos, Bento C

    2010-04-01

    A severe disadvantage of administration of recombinant human erythropoietin to hemodialysis patients has been reported. A significant correlation has been shown with hemoglobin values determined online by use of the blood volume monitor (BVM) and by laboratory measurement. Online hemoglobin and hematocrit were measured by use of the BVM during hemodialysis session. Data were analyzed by t test and statistical significance was defined as a P of hemoglobin and hematocrit from 11.6 +/- 1.9 to 13.9 +/- 2.4 g/dL (17.4 +/- 7.1%, P = 0.02) and from 34.4 +/- 6.8 to 42 +/- 8.3% (20.6 +/- 8.8%, P = 0.022), respectively, were observed from the beginning to the end of dialysis. We hypothesize that a new strategy for adjusting erythropoietin dose may be based on hemoglobin and hematocrit values evaluated at the end of hemodialysis, when patients are no longer hypervolemic. Inadvertent high levels of hemoglobin could be one explanation why patients present higher rates of cardiovascular and access-related events, especially when monitored online by use of the BVM to achieve the dry weight.

  16. Storage time of platelet concentrates and risk of a positive blood culture

    DEFF Research Database (Denmark)

    Kreuger, Aukje L; Rostgaard, Klaus; Middelburg, Rutger A

    2018-01-01

    BACKGROUND: Concern of transfusion-transmitted bacterial infections has been the major hurdle to extend shelf life of platelet (PLT) concentrates. We aimed to investigate the association between storage time and risk of positive blood cultures at different times after transfusion. STUDY DESIGN...... AND METHODS: We performed a nationwide cohort study among PLT transfusion recipients in Denmark between 2010 and 2012, as recorded in the Scandinavian Donations and Transfusions (SCANDAT2) database. Linking with a nationwide database on blood cultures (MiBa), we compared the incidence of a positive blood......) of a positive blood culture the day after transfusion of at least one old PLT concentrate was 0.77 (95% confidence interval [CI], 0.54-1.09) compared to transfusion of fresh PLT concentrates. The incidence rate of a positive blood culture was lower the day after receiving one old compared to one fresh PLT...

  17. Oxygen binding properties of hemoglobin from the white rhinoceros (beta 2-GLU) and the tapir.

    Science.gov (United States)

    Baumann, R; Mazur, G; Braunitzer, G

    1984-04-01

    The beta-chain of rhinoceros hemoglobin contains glutamic acid at position beta 2, and important site for the binding of organic phosphates. We have investigated the oxygen binding properties of this hemoglobin and its interaction with ATP, 2,3-diphosphoglycerate, CO2 and chloride. The results show that the presence of GLU at position beta 2 nearly abolishes the effect of organic phosphates and CO2, whereas the oxygen-linked binding of chloride is not affected. Thus rhinoceros hemoglobin has only protons and chloride anions as major allosteric effectors for the control of its oxygen affinity. From the results obtained with hemoglobin solutions it can be calculated that the blood oxygen affinity of the rhinoceros must be rather high with a P50 of about 20 torr at pH 7.4 and 37 degrees C, which conforms with observations obtained for other large mammals.

  18. BLOOD LEAD CONCENTRATION AND DELAYED PUBERTY IN GIRLS

    Science.gov (United States)

    Background Environmental lead exposure has been linked to alterations in growth and endocrine function. It is not known whether such exposure affects pubertal development.Methods We analyzed the relations between blood lead concentration and pubertal...

  19. Optical Spectra of Hemoglobin Taken from Alcohol Dependent Humans

    OpenAIRE

    Dudok K.; Dudok T.; Vlokh I.; Vlokh R.

    2005-01-01

    Optical spectra of CNMetHb and CNMetHb-Coomassi G-250, taken from the blood of humans with alcohol dependence, are studied in the spectral range of 450–750nm. The shifts in the spectral absorption maxima of CNMetHb-Coomassi G-250 complexes are observed for the diseased persons with alcohol dependence. The obtained results show that the hemoglobin structure of alcohol dependent humans is changed.

  20. Whole-Blood Taurine Concentrations in Cats With Intestinal Disease.

    Science.gov (United States)

    Kathrani, A; Fascetti, A J; Larsen, J A; Maunder, C; Hall, E J

    2017-07-01

    Increased delivery of taurine-conjugated bile acids to the distal bowel can lead to dysbiosis resulting in colitis in mouse models of inflammatory bowel disease. A similar situation also could occur in cats with intestinal disease and might therefore result in decreased whole-body taurine concentration. To determine whether whole-blood taurine concentrations are decreased at the time of diagnosis in cats with intestinal disease and to correlate concentrations with clinical and laboratory variables. Twenty-one cats with chronic inflammatory enteropathy and 7 cats with intestinal neoplasia from the University of Bristol. Cats that had undergone a thorough investigation consisting of a CBC, serum biochemistry, serum cobalamin and folate concentrations, transabdominal ultrasound examination and histopathology of intestinal biopsy specimens, as well as additional testing if indicated, were included. Whole-blood from these cats collected at the time of histologic diagnosis and stored in ethylenediaminetetraacetic acid was retrospectively analyzed for taurine with an automated high-performance liquid chromatography amino acid analyzer. Although whole-blood taurine concentrations remained within the reference range, those cats with predominantly large intestinal clinical signs had significantly lower concentrations than did cats with small intestinal and mixed bowel clinical signs (P = 0.033) and this difference also was significant when assessed only in cats with chronic inflammatory enteropathy (P = 0.019). Additional studies are needed to determine whether large intestinal signs in cats with chronic inflammatory enteropathy are caused by alterations in the microbiota arising as a consequence of increased delivery of taurine-conjugated bile acids. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  1. Hemoglobin C, S-C, and E Diseases

    Science.gov (United States)

    ... quickly than others, resulting in chronic anemia. Hemoglobin C disease Hemoglobin C disease occurs mostly in blacks. ... a common complication of hemoglobin C disease. Hemoglobin S-C disease Hemoglobin S-C disease occurs in people who ...

  2. Adult, embryonic and fetal hemoglobin are expressed in human glioblastoma cells.

    Science.gov (United States)

    Emara, Marwan; Turner, A Robert; Allalunis-Turner, Joan

    2014-02-01

    Hemoglobin is a hemoprotein, produced mainly in erythrocytes circulating in the blood. However, non-erythroid hemoglobins have been previously reported in other cell types including human and rodent neurons of embryonic and adult brain, but not astrocytes and oligodendrocytes. Human glioblastoma multiforme (GBM) is the most aggressive tumor among gliomas. However, despite extensive basic and clinical research studies on GBM cells, little is known about glial defence mechanisms that allow these cells to survive and resist various types of treatment. We have shown previously that the newest members of vertebrate globin family, neuroglobin (Ngb) and cytoglobin (Cygb), are expressed in human GBM cells. In this study, we sought to determine whether hemoglobin is also expressed in GBM cells. Conventional RT-PCR, DNA sequencing, western blot analysis, mass spectrometry and fluorescence microscopy were used to investigate globin expression in GBM cell lines (M006x, M059J, M059K, M010b, U87R and U87T) that have unique characteristics in terms of tumor invasion and response to radiotherapy and hypoxia. The data showed that α, β, γ, δ, ζ and ε globins are expressed in all tested GBM cell lines. To our knowledge, we are the first to report expression of fetal, embryonic and adult hemoglobin in GBM cells under normal physiological conditions that may suggest an undefined function of those expressed hemoglobins. Together with our previous reports on globins (Ngb and Cygb) expression in GBM cells, the expression of different hemoglobins may constitute a part of series of active defence mechanisms supporting these cells to resist various types of treatments including chemotherapy and radiotherapy.

  3. [Positive Distribution Rate of Coombs Test in Patients with Clinical Anemia and Blood Transfusion and Its Effect on Clinical Blood Transfusion].

    Science.gov (United States)

    Wu, Gang; Duan, Yu-Han

    2018-02-01

    To study the positive distribution rate of Coombs test in patients with clinical anemia and blood transfusion, and its effect on clinical blood transfusion. Seventy patients with hemoglobin level in the normal range were enrolled into control group, while 130 patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel antihuman globin detection card and 70 surgical patients with anemia or blood transfusion who' s hemoglobin level was lower comfirmed by micro-column gel anti-human globin card were enrolled into anemia or blood transfusion (A or BT) group. And coomb' s test performed for all the patients, in which the positive patients in Department of Internal Medicine need to be re-typed. Among 70 surgical patients with anemia or blood transfusion, 14 cases were directly detected to be anti-human globine positive with detection rate 20%; among 130 internal medicine patients with anemia or blood transfusion, 54 cases were directly detected to be anti-human globine positive with detection rate 41.4%. Among 270 cases, the highest positive rate (66.7%) was observed in patients with 50-59 g/L of hemoglobin. According to type test, the samples of 54 patients with anemia in Department of Internal Medicine, who were directly selected to be anti-human globin positive, could be divided into anti-C3d(7 cases, accounting for 13.0%), anti-IgG(12 cases accounting for, 22.2%) and anti-C3d+anti-IgG(35 cases, accounting for 64.8%), while according to diseases, the anti-human globin positive ratio was high in tumor cancer, hephropathy and gastroenteropathy patients, and patients in intensive care unit, moreover the blood transfusion frequency of these patients was higher than that of patients with anti-human globin negative(Pblood transfusion, so as to ensure the effectiveness of blood transfusion.

  4. SPECTROPHOTOMETRY OF HEMOGLOBIN - ABSORPTION-SPECTRA OF RAT OXYHEMOGLOBIN, DEOXYHEMOGLOBIN, CARBOXYHEMOGLOBIN, AND METHEMOGLOBIN

    NARCIS (Netherlands)

    ZIJLSTRA, WG; BUURSMA, A; FALKE, HE; CATSBURG, JF

    The absorptivity at 540 nm of methemoglobincyanide from rat blood was determined on the basis of iron and found to be equal to the established value for human methemoglobincyanide (11,01/mmol/cm). On this basis the absorption spectra of the common derivatives were determined for rat hemoglobin.

  5. The Prognostic Value of Hemoglobin Concentration in Postoperative Radiotherapy of 835 Patients With Laryngeal Cancer

    International Nuclear Information System (INIS)

    Rutkowski, Tomasz; Suwinski, Rafal; Idasiak, Adam

    2007-01-01

    Purpose: To investigate the prognostic value of hemoglobin (Hb) concentration in patients with laryngeal cancer treated with postoperative radiotherapy (pRT). Methods and Materials: The records of 835 patients who underwent pRT between 1980 and 2003 were reviewed. Most patients (526 of 835 patients; 63%) were in advanced clinical stages (T3-T4) and 371 of 835 patients (44%) were node positive. Total laryngectomy had been performed in 676 of 835 patients (81%). Median Hb concentration before (Hb0) and after pRT (Hb1) was the same (13.3 g/dl). However, individual differences between Hb1 and Hb0 (dHb) varied within a broad range (-8.8; 5.0 g/dl). Univariate and multivariate analyses were performed to identify variables significantly associated with locoregional control (LRC), metastases-free survival, and overall survival. Results: Patients with dHb greater than 0 had significantly improved 5-year LRC compared with those with dHb of 0 or less (80% vs. 72%, p = 0.01). Conversely, when categorized, neither Hb0 nor Hb1 had a significant influence on LRC. In multivariate analysis, dHb remained a prognostic factor for LRC (p = 0.01) among the other variables, which included overall radiation treatment time and nodal status. None of the Hb-related variables significantly influenced metastases-free or overall survival. Conclusion: Individual change in Hb concentration during the course of pRT (dHb) rather than Hb level before or after pRT appeared as an independent prognostic factor for LRC in this set of patients

  6. Molecular dynamics simulations indicate that deoxyhemoglobin, oxyhemoglobin, carboxyhemoglobin, and glycated hemoglobin under compression and shear exhibit an anisotropic mechanical behavior.

    Science.gov (United States)

    Yesudasan, Sumith; Wang, Xianqiao; Averett, Rodney D

    2018-05-01

    We developed a new mechanical model for determining the compression and shear mechanical behavior of four different hemoglobin structures. Previous studies on hemoglobin structures have focused primarily on overall mechanical behavior; however, this study investigates the mechanical behavior of hemoglobin, a major constituent of red blood cells, using steered molecular dynamics (SMD) simulations to obtain anisotropic mechanical behavior under compression and shear loading conditions. Four different configurations of hemoglobin molecules were considered: deoxyhemoglobin (deoxyHb), oxyhemoglobin (HbO 2 ), carboxyhemoglobin (HbCO), and glycated hemoglobin (HbA 1C ). The SMD simulations were performed on the hemoglobin variants to estimate their unidirectional stiffness and shear stiffness. Although hemoglobin is structurally denoted as a globular protein due to its spherical shape and secondary structure, our simulation results show a significant variation in the mechanical strength in different directions (anisotropy) and also a strength variation among the four different hemoglobin configurations studied. The glycated hemoglobin molecule possesses an overall higher compressive mechanical stiffness and shear stiffness when compared to deoxyhemoglobin, oxyhemoglobin, and carboxyhemoglobin molecules. Further results from the models indicate that the hemoglobin structures studied possess a soft outer shell and a stiff core based on stiffness.

  7. Mössbauer studies of hemoglobin in high altitude polycythemia

    Science.gov (United States)

    Xiufang, Zhang; Linming, Shen; Songsen, Chen; Yuanyuan, Liu; Naifei, Gao; Yuanming, Zheng; Zhaohui, Ao; Liangquan, Shong

    1990-07-01

    The Mössbauer spectra have been measured in erythrocytes from normal adults and the patients with high altitude polycythemia (HAPC). The results indicated that two subspectra “a” and “b”, corresponding to oxy- and deoxyhemoglobin respectively, were present in all blood samples, and a third subspectrum “c” was found to exist in almost all samples from the patients. The parameters of the third subspectra “cl” in most samples from the patients were similar to those of carbon monoxyhemoglobin. The components were considered to be the denatured hemoglobin in RBCs (red blood cells). Together with clinical analysis, a possible mechanism of HAPC has been discussed.

  8. Correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer and serum glucose concentration measured by an automated biochemical analyzer for canine and feline blood samples.

    Science.gov (United States)

    Tauk, Barbara S; Drobatz, Kenneth J; Wallace, Koranda A; Hess, Rebecka S

    2015-06-15

    To investigate the correlation between glucose concentrations in serum, plasma, and whole blood measured by a point-of-care glucometer (POCG) and serum glucose concentration measured by a biochemical analyzer. Prospective clinical study. 96 blood samples from 80 dogs and 90 blood samples from 65 cats. Serum, plasma, and whole blood were obtained from each blood sample. The glucose concentrations in serum, plasma, and whole blood measured by a POCG were compared with the serum glucose concentration measured by a biochemical analyzer by use of the Lin concordance correlation coefficient (ρc) and Bland-Altman plots. For both canine and feline samples, glucose concentrations in serum and plasma measured by the POCG were more strongly correlated with the serum glucose concentration measured by the biochemical analyzer (ρc, 0.98 for both canine serum and plasma; ρc, 0.99 for both feline serum and plasma) than was that in whole blood (ρc, 0.62 for canine samples; ρc, 0.90 for feline samples). The mean difference between the glucose concentrations determined by the biochemical analyzer and the POCG in serum, plasma, and whole blood was 0.4, 0.3, and 31 mg/dL, respectively, for canine samples and 7, 6, and 32 mg/dL, respectively, for feline samples. Results indicated that use of a POCG to measure glucose concentrations in serum or plasma may increase the accuracy and reliability of diagnostic and treatment decisions associated with glucose homeostasis disorders in dogs and cats.

  9. Clinical Significance of Reticulocyte Hemoglobin Content in the Diagnosis of Iron Deficiency Anemia

    Directory of Open Access Journals (Sweden)

    Mustafa Karagülle

    2013-06-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the clinical significance of reticulocyte hemoglobin content (CHr in the diagnosis of iron deficiency anemia (IDA and to compare it with other conventional iron parameters. METHODS: A total of 32 female patients with IDA (serum hemoglobin 120 g/L and serum ferritin <20 ng/mL were enrolled. RESULTS: CHr was 24.95±3.92 pg in female patients with IDA and 29.93±2.96 pg in female patients with iron deficiency. CHr showed a significant positive correlation with hemoglobin, mean corpuscular volume, mean corpuscular hemoglobin, mean corpuscular hemoglobin concentration, serum iron, and transferrin saturation and a significant negative correlation with transferrin and total iron-binding capacity. The cut-off value of CHr for detecting IDA was 29 pg. CONCLUSION: Our data demonstrate that CHr is a useful parameter that can be confidently used in the diagnosis of IDA, and a CHr cut-off value of 29 pg predicts IDA.

  10. Blood cadmium concentration and lipid profile in Korean adults

    International Nuclear Information System (INIS)

    Kim, Kisok

    2012-01-01

    Although animal experiments have shown that cadmium exposure induces alterations in lipid profiles, no epidemiological study of this relationship has been performed. The objective of this study was to evaluate the association between blood cadmium concentration and blood lipid levels in Korean adults. A cross-sectional study comprising participants (n=3903) aged 20 years or older from the 2005, 2008, and 2009 Korea National Health and Nutrition Examination Surveys was conducted. Demographic characteristics and dietary intake were obtained from the participants by questionnaire, and cadmium and lipid levels were determined by analysis of blood samples. After adjusting for demographic and dietary factors, blood concentration of cadmium was positively associated with the risk of low high-density lipoprotein cholesterol (HDL-C) in a dose-dependent manner (p for trend <0.001). In addition, the odds ratios (ORs) of a high triglyceride to HDL-C ratio was significantly increased in the high blood cadmium groups [OR=1.36; 95% confidence interval (CI), 1.03–1.79 for fourth quintile and OR=1.41; 95% CI, 1.07–1.86 for fifth quintile] compared with the lowest quintile group. However, high blood cadmium was not associated with a risk of high total cholesterol, high low-density lipoprotein cholesterol, or high triglycerides. These data suggest that an increased cadmium body burden increases the risk of dyslipidemia, mainly due to the increased risk of low HDL-C and the high ratio of triglycerides to HDL-C.

  11. Blood cadmium concentration and lipid profile in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kisok [Department of Public Health, Keimyung University, 1000 Shindang-dong, Daegu 704-701 (Korea, Republic of)

    2012-01-15

    Although animal experiments have shown that cadmium exposure induces alterations in lipid profiles, no epidemiological study of this relationship has been performed. The objective of this study was to evaluate the association between blood cadmium concentration and blood lipid levels in Korean adults. A cross-sectional study comprising participants (n=3903) aged 20 years or older from the 2005, 2008, and 2009 Korea National Health and Nutrition Examination Surveys was conducted. Demographic characteristics and dietary intake were obtained from the participants by questionnaire, and cadmium and lipid levels were determined by analysis of blood samples. After adjusting for demographic and dietary factors, blood concentration of cadmium was positively associated with the risk of low high-density lipoprotein cholesterol (HDL-C) in a dose-dependent manner (p for trend <0.001). In addition, the odds ratios (ORs) of a high triglyceride to HDL-C ratio was significantly increased in the high blood cadmium groups [OR=1.36; 95% confidence interval (CI), 1.03-1.79 for fourth quintile and OR=1.41; 95% CI, 1.07-1.86 for fifth quintile] compared with the lowest quintile group. However, high blood cadmium was not associated with a risk of high total cholesterol, high low-density lipoprotein cholesterol, or high triglycerides. These data suggest that an increased cadmium body burden increases the risk of dyslipidemia, mainly due to the increased risk of low HDL-C and the high ratio of triglycerides to HDL-C.

  12. Circadian melatonin concentration rhythm is lost in pregnant women with altered blood pressure rhythm.

    Science.gov (United States)

    Tranquilli, A L; Turi, A; Giannubilo, S R; Garbati, E

    2004-03-01

    We assessed the correlation between the rhythm of melatonin concentration and circadian blood pressure patterns in normal and hypertensive pregnancy. Ambulatory 24-h blood pressure and blood samples every 4 h were monitored in 16 primigravidae who had shown an abnormal circadian blood pressure pattern (eight pre-eclamptic and eight normotensive) in pregnancy and 6-12 months after pregnancy. The circadian rhythm was analyzed by chronobiological measures. Eight normotensive women with maintained blood pressure rhythm served as controls. During pregnancy, melatonin concentration was significantly higher in pre-eclamptic than in normotensive women (pre-eclampsia, 29.4 +/- 1.9 pg/ml, normotensin, altered rhythm, 15.6 +/- 2.1; controls, 22.7 +/- 1.8; p lost in all pregnant women with loss of blood pressure rhythm. After pregnancy, normotensive women showed a reappearance of both melatonin and blood pressure rhythm, whereas pre-eclamptic women showed a reappearance of blood pressure but not melatonin rhythm. The loss of blood pressure rhythm in pregnancy is consistent with the loss of melatonin concentration rhythm. In pre-eclamptic women, the normalization of blood pressure rhythm, while melatonin rhythm remained altered, suggests a temporal or causal priority of circadian concentration of melatonin in the determination of blood pressure trend.

  13. Empirical modelling to predict the refractive index of human blood

    Science.gov (United States)

    Yahya, M.; Saghir, M. Z.

    2016-02-01

    Optical techniques used for the measurement of the optical properties of blood are of great interest in clinical diagnostics. Blood analysis is a routine procedure used in medical diagnostics to confirm a patient’s condition. Measuring the optical properties of blood is difficult due to the non-homogenous nature of the blood itself. In addition, there is a lot of variation in the refractive indices reported in the literature. These are the reasons that motivated the researchers to develop a mathematical model that can be used to predict the refractive index of human blood as a function of concentration, temperature and wavelength. The experimental measurements were conducted on mimicking phantom hemoglobin samples using the Abbemat Refractometer. The results analysis revealed a linear relationship between the refractive index and concentration as well as temperature, and a non-linear relationship between refractive index and wavelength. These results are in agreement with those found in the literature. In addition, a new formula was developed based on empirical modelling which suggests that temperature and wavelength coefficients be added to the Barer formula. The verification of this correlation confirmed its ability to determine refractive index and/or blood hematocrit values with appropriate clinical accuracy.

  14. Comparison of point-of-care versus central laboratory measurement of hematocrit, hemoglobin, and electrolyte concentrations.

    Science.gov (United States)

    Gavala, Alexandra; Myrianthefs, Pavlos

    We aimed to investigate the accuracy of certain laboratory examinations obtained by the ABG analyzer (ROCHE AVL OMNI S) as compared to hospital central laboratory (CL). We prospectively collected data obtained from the same arterial blood sample regarding hematocrit, hemoglobin, potassium, and sodium. ABG analyzer results were significantly lower (p < 0.0001) compared to CL values thus values between the two methods are not interchangeable. The mean bias for Hb, Na + and K + were within accepted by US Clinical Laboratory Improvement Amendment (USCLIA) differences (cut-off points) but not for Ht. In 8.0%, 17.5%, 37.5% and 56.0% of Hb, Na + , K + and Ht measurements respectively and 29.75% in sum the differences were over the USCLIA accepted limits. ABG analyzer significantly underestimate the values of Hb, Ht, Na + and K + , compared to CL and almost 30% of all examined parameters were beyond USCLIA accepted biases. ABG analyzer significantly underestimates the values of Hb, Ht, Na + and K + compared to CL and almost 30% for all examined parameters are beyond USCLIA accepted biases. These data do not support widespread or even careful use of POCT for making diagnostic and treatment decisions until technology improves and results in improved outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Blood samples in the neutron beam; Blutproben im Neutronenstrahl

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2012-07-01

    Whether crocodile, platypus, man, or chicken: Always the hemoglobin in the red blood cells has the same task. It carries oxygen from the lungs throughout the body. In investigative manner and international team around Dr. Andreas Stadler from the Julic Research Center has deciphered in detail, how and why the hemoglobines of these creatures nevertheless differ. Their findings are among others interesting for the research on artificial blood.

  16. Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements

    Science.gov (United States)

    Ridder, Trent D.; Ver Steeg, Benjamin J.; Laaksonen, Bentley D.

    2009-09-01

    Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

  17. Assessment of changes in plasma hemoglobin and potassium levels in red cell units during processing and storage.

    Science.gov (United States)

    Saini, Nishant; Basu, Sabita; Kaur, Ravneet; Kaur, Jasbinder

    2015-06-01

    Red cell units undergo changes during storage and processing. The study was planned to assess plasma potassium, plasma hemoglobin, percentage hemolysis during storage and to determine the effects of outdoor blood collection and processing on those parameters. Blood collection in three types of blood storage bags was done - single CPDA bag (40 outdoor and 40 in-house collection), triple CPD + SAGM bag (40 in-house collection) and quadruple CPD + SAGM bag with integral leukoreduction filter (40 in-house collection). All bags were sampled on day 0 (day of collection), day 1 (after processing), day 7, day 14 and day 28 for measurement of percentage hemolysis and potassium levels in the plasma of bag contents. There was significant increase in percentage hemolysis, plasma hemoglobin and plasma potassium level in all the groups during storage (p levels during the storage of red blood cells. Blood collection can be safely undertaken in outdoor blood donation camps even in hot summer months in monitored blood transport boxes. SAGM additive solution decreases the red cell hemolysis and allows extended storage of red cells. Prestorage leukoreduction decreases the red cell hemolysis and improves the quality of blood. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Blood lead exposure concentrations in mottled ducks (Anas fulvigula) on the upper Texas coast

    Science.gov (United States)

    McDowell, Stephen K.; Conway, Warren C.; Haukos, David A.; Moon, Jena A.; Comer, Christopher E.; Hung, I-Kuai

    2015-01-01

    The mottled duck (Anas fulvigula) is a non-migratory waterfowl species dependent upon coastal marsh systems, including those on the Texas Chenier Plain National Wildlife Refuge (NWR) Complex, and considered a regional indicator species of marsh habitat quality. Research from the early 1970s, 1990s, and early-2000s indicated that mottled ducks continued to exhibit elevated wing-bone lead (Pb) concentrations, decades after implementation of non-toxic shot regulations. However, wing-bone concentrations reflect lifetime accumulation of Pb, whereas blood Pb concentrations reflect more recent exposure. To identify current potentially relevant temporal windows of Pb exposure, we collected 260 blood samples from mottled ducks during summer (n=124) and winter (n=136) from 2010–2012 on the Texas Chenier Plain NWR Complex. We quantified baseline blood Pb concentrations for all ages of mottled ducks, and hypothesized that blood lead concentrations would remain elevated above background levels (200 µg L–1) despite the 1983 and 1991 lead shot bans. Blood Pb concentrations ranged from below detection limits to >12,000 µg L–1, where >200 µg L–1 was associated with exposure levels above background concentrations. Male mottled ducks had the greatest blood Pb concentrations (30 times greater than females) with concentrations greater during winter than summer. Likewise, the proportion of exposed (>200 µg L–1) females increased from 14%–47% from summer to winter, respectively. Regardless of sex, adult mottled duck blood Pb concentrations were five times greater than juveniles, particularly during winter. We identified five plausible models that influenced blood Pb levels where year, site, and interactions among age*sex*season and between age*season were included in the top-ranked models. Frequency of exposure was greatest during winter, increasing from 12% in summer to 55% in winter, indicating that a temporal exposure window to environmental Pb exists between nesting

  19. The effects of venous cannulation technique and cardioplegia type on plasma potassium concentration and arterial blood pressure during cardiopulmonary bypass.

    LENUS (Irish Health Repository)

    Coleman, E T

    2012-02-03

    The cannulation method and cardioplegia solution used during cardiopulmonary bypass (CPB) may both influence plasma potassium concentrations ([K+]) and mean arterial blood pressure (MAP). Bi-caval or right atrial cannulation methods are routinely used in conjunction with crystalloid or blood cardioplegia. We investigated the influence of cannulation method and cardioplegia solutions on plasma [K+] and MAP during cardiopulmonary bypass. Sixty consecutive patients undergoing elective coronary artery bypass grafting (CABG) using CPB were studied. They were randomly divided into three groups of 20 patients. Patients in Group A underwent bi-caval venous cannulation and received crystalloid cardioplegia. Group B patients underwent right atrial cannulation and received crystalloid cardioplegia. Group C patients underwent right atrial cannulation and received blood cardioplegia. In each case. cardioplegia was administered antegrade via the aortic root. Plasma [K+], MAP. and hemoglobin concentration (Hb) were measured over an 8-min period following cardioplegia administration (pilot studies indicated pressure changes occuring post cardioplegia administration up to this time). The combination of bi-caval cannulation and crystalloid cardioplegia (Group A) was associated with the least increase in plasma [K+] and no decrease in MAP. The maximum [K+] for this Group was 4.2 mmol\\/L (4.6% increase). The minimum mean pressure was 57 mmHg (13.6% increase). Both right atrial cannulation groups (B and C) showed a large rise in plasma [K+] and a decrease in MAP. Group B maximum [K+] was 5.2 mmol\\/L (27.5% increase). Group C was also 5.2 mmol\\/L (26.0% increase). Group C showed the largest pressure decrease, the minimum mean pressure was 45 mmHg (21.3% decrease). The Group B minimum mean pressure was 45 mmHg (8.7% decrease). Our results show that patients undergoing CPB operations who are deemed to be at increased risk of suffering adverse effects from hypotensive episodes may

  20. The changes of red blood cell viscoelasticity and sports anemia in male 24-hr ultra-marathoners

    Directory of Open Access Journals (Sweden)

    Che-Hung Liu

    2018-05-01

    Full Text Available Background: In endurance sports, stress, dehydration and release of chemical factors have been associated with red blood cell (RBC alterations of structure and function, which may contribute to sports anemia, a well-observed phenomenon during long-distance running. Until now, the investigation of the changes of viscoelastic properties of RBC membrane, a decisive factor of RBC deformability to avoid hemolysis, is lacking, especially in an Oriental population. Methods: nineteen runners were prospectively recruited into our study. Hematological parameters were analyzed before and immediately after the 2015 Taipei 24H Ultra-Marathon Festival, Taiwan. Video particle tracking microrheology was used to determine viscoelastic properties of each RBC sample by calculating the dynamic elastic modulus G′(f and the viscous modulus G″(f at frequency f = 20 Hz. Results: Haptoglobin, RBC count, hemoglobin, hematocrit, mean cell hemoglobin, plasma free hemoglobin and unsaturated iron-binding capacity values of the recruited runners showed a statistically significant drop in the post-race values. Blood concentration of reticulocyte and ferritin were significantly higher at post-race compared with pre-race. 15 out of the 19 runners had a concurrent change in the elastic and the viscous moduli of their RBCs. Changes in the elastic and the viscous moduli were correlated with changes in the RBC count, hemoglobin and hematocrit. Conclusion: Viscoelasticity properties, the elastic modulus G′(f and the viscous modulus G″(f of RBCs are associated with endurance exercise-induced anemia. Keywords: Clinical sports medicine, Red blood cell, Sports anemia, Ultra-marathon, Viscoelastic properties

  1. Pulsed high voltage discharge induce hematologic changes | El ...

    African Journals Online (AJOL)

    For basic hematology we determined the hematocrit (HCT), hemoglobin (HGB), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). For differential blood count the number of red blood cells (RBC) and white blood cells (WBC), which were ...

  2. Validation and modification of dried blood spot-based glycosylated hemoglobin assay for the longitudinal aging study in India.

    Science.gov (United States)

    Hu, Peifeng; Edenfield, Michael; Potter, Alan; Kale, Varsha; Risbud, Arun; Williams, Sharon; Lee, Jinkook; Bloom, David E; Crimmins, Eileen; Seeman, Teresa

    2015-01-01

    This study aims to validate a modified dried blood spot (DBS)-based glycosylated hemoglobin (HbA1c) assay protocol, after a pretest in India showed poor correlation between the original DBS-based protocol and venous results. The original protocol was tested on different chemistry analyzers and then simplified at the University of Washington (UW). A second pretest was conducted in India to validate the modified assay protocol, using 44 quality control specimens. Data from UW indicated that, using the original protocol, the correlation coefficients between DBS and venous results were above 0.98 on both Bio-Rad and Olympus chemistry analyzers. The protocol worked equally well on filter paper, with or without pre-treatment, and when the recommended amount of blood spot material, or less, was used. A second pretest of the modified protocol confirmed that DBS-based levels from both Olympus and Roche chemistry analyzers were well correlated with DBS results from UW (correlation coefficients were above 0.96), as well as with venous values (correlation coefficients were above 0.94). The DBS-based HbA1c values are highly correlated with venous results. The pre-treatment of filter paper does not appear to be necessary. The poor results from the first pretest are probably due to factors unrelated to the protocol, such as problems with the chemistry analyzer or assay reagents. © 2015 Wiley Periodicals, Inc.

  3. Aerobic bacterial microbiota of the conjunctiva in diabetic patients with normal and altered glycated hemoglobin levels in two regions in Brazil

    Directory of Open Access Journals (Sweden)

    Natalia Pimentel Moreno

    2014-12-01

    Full Text Available Purpose: To study the aerobic bacterial microbiota of the conjunctiva in diabetic patients with regard to the management of diabetes, assessed using glycated hemoglobin levels. Methods: A cross-sectional study was conducted using conjunctival smears of diabetic patients from both sexes and with different ages, residing in two different Brazilian cities (Sorocaba and Rio Branco. A control group of non-diabetic patients was also included. The diabetic patients were considered to have controlled diabetes when their glycated hemoglobin level was ≤7% and blood glucose level was ≤126 mg/dL. Patients with non-controlled diabetes were those with glycated hemoglobin levels >7% and blood glucose levels >126 mg/dL. The samples obtained were inoculated in Brain-Heart Infusion broth and in culture media for aerobic bacteria (blood and chocolate agars; bacterial growth was evaluated in a microbiology laboratory. Results: A total of 120 eyes of 120 patients were included in the present study. The percentage of cultures in which bacterial growth was observed was greater in diabetic patients, although the difference was not statistically significant (p=0.103. There was a greater trend toward bacterial growth in the conjunctiva of diabetic patients with altered fasting blood glucose. There was no difference in the frequency of bacterial growth on the conjunctiva between diabetic patients with normal or altered glycated hemoglobin levels. In Sorocaba, conjunctival bacterial growth was similar to that observed in Rio Branco. The microorganism most frequently detected in the present study was Staphylococcus epidermidis, followed by Staphylococcus aureus, Proteus mirabilis, and Escherichia coli. Conclusion: There was no difference between diabetic patients with normal or altered glycated hemoglobin levels. The microorganisms found were similar to those found in studies investigating the conjunctival bacterial flora of diabetic and non-diabetic patients.

  4. Evidence that the low-affinity folate-binding protein in erythrocyte hemolysate is identical to hemoglobin

    International Nuclear Information System (INIS)

    Hansen, S.I.; Holm, J.; Lyngbye, J.

    1981-01-01

    Gel filtration studies on erythrocyte hemolysate demonstrated the presence of a folate binding protein, apparently of the low-affinity type, that co-elutes with hemoglobin. Further, the folate binder eluted with a low salt concentration after DEAE-Sepharose CL-6B anion-exchange chromatography of erythrocyte hemolysate at pH 6.3. The chromatographic behavior of hemoglobin labeled with [3H]folate was so similar to that of the present binder as to suggest that the folate binder in erythrocytes is in fact hemoglobin

  5. Association of ITPA gene variation and serum ribavirin concentration with a decline in blood cell concentrations during pegylated interferon-alpha plus ribavirin therapy for chronic hepatitis C.

    Science.gov (United States)

    Nakagawa, Mina; Sakamoto, Naoya; Watanabe, Takako; Nishimura-Sakurai, Yuki; Onozuka, Izumi; Azuma, Seishin; Kakinuma, Sei; Nitta, Sayuri; Kiyohashi, Kei; Kusano-Kitazume, Akiko; Murakawa, Miyako; Yoshino, Kohei; Itsui, Yasuhiro; Tanaka, Yasuhito; Mizokami, Masashi; Watanabe, Mamoru

    2013-03-01

    Genetic variation leading to inosine triphosphatase (ITPA) deficiency protects chronic hepatitis C patients receiving ribavirin against hemolytic anemia. The relationship between ITPA gene variation and serum ribavirin concentration was analyzed in association with a reduction in blood cells and dose reduction of pegylated interferon (PEG-IFN) or ribavirin. A total of 300 hepatitis C patients treated with PEG-IFN plus ribavirin were analyzed. Genetic polymorphisms were determined in ITPA and the quantitative reduction in blood cells from the baseline was analyzed every 4 weeks for the duration of treatment and after the end of therapy. The decline in hemoglobin (Hb) or platelet (PLT) level at week 4 compared to baseline was also assessed according to ribavirin concentrations. Patients with the ITPA-CA/AA genotypes showed a lower degree of Hb reduction throughout therapy than those with the ITPA-CC genotype and a marked difference in mean Hb reduction was found at week 4 (CA/AA -1.0 vs. CC -2.8, p < 0.001). The ITPA-CC genotype had significantly less reduction in the mean platelet count than the ITPA-CA/AA genotypes early during treatment (p < 0.001 for weeks 4 and 8). Patients with the ITPA-CA/AA genotypes were less likely to develop anemia, regardless of the concentration of ribavirin. Patients with baseline PLT counts below 130 × 10(3)/μl had a significantly lower tendency to achieve sustained virological response (SVR), especially those with the ITPA-CA/AA genotypes. ITPA gene variation was not extracted by multivariable analysis as an important predictor of SVR. Despite the fact that ITPA variants were less likely to develop anemia, patients with low baseline PLT counts were difficult to treat, especially those with the ITPA-CA/AA genotype. These results may give a valuable pharmacogenetic diagnostic tool for the tailoring of dosing to minimize drug-induced adverse events.

  6. Resting blood lactate in individuals with sickle cell disease

    Directory of Open Access Journals (Sweden)

    Jefferson Petto

    2011-02-01

    Full Text Available BACKGROUND: The most common hereditary hemoglobin disorder, affecting 20 million individuals worldwide, is sickle cell disease. The vascular obstruction resulting from the sickling of cells in this disease can produce local hypoxemia, pain crises and infarction in several tissues, including the bones, spleen, kidneys and lungs. METHODS: The present study is characterized as a case control study, with the aim of identifying the baseline blood lactate concentration in individuals with hemoglobin SS and SC diseases. One-way ANOVA with the Tukey post-test was used to analyze the results and a p-value < 0.05 was considered significant. Calculations were made using the INSTAT statistical program. The graphs were generated using the ORING program. The study sample was composed of 31 men and women residing in the city of Santo Antônio de Jesus, Bahia, Brazil. The individuals were divided into two groups: Group GC of 16 subjects who did not present with any type of structural hemoglobinopathy; and Group GE composed of 15 individuals with ages between 2 and 35 years old, who had the SS and SC genotypes. Sample analyses were performed with 3 mL of blood during fasting. RESULTS: The baseline blood lactate concentration of the SS and SC individuals was higher than that of the control group (p<0.001 with means of 4.86 ± 0.95; 3.30 ± 0.33; 1.31 ± 0.08 IU/L for SS, SC and controls, respectively. This corroborates the initial research hypothesis. CONCLUSION: The baseline blood lactate of SS and SC individuals is 3 to 4 times higher than that of healthy subjects, probably due to the fact that these patients have a metabolic deviation to the anaerobic pathway.

  7. Nitric Oxide in Plants: The Roles of Ascorbate and Hemoglobin

    Science.gov (United States)

    Wang, Xiaoguang; Hargrove, Mark S.

    2013-01-01

    Ascorbic acid and hemoglobins have been linked to nitric oxide metabolism in plants. It has been hypothesized that ascorbic acid directly reduces plant hemoglobin in support of NO scavenging, producing nitrate and monodehydroascorbate. In this scenario, monodehydroascorbate reductase uses NADH to reduce monodehydroascorbate back to ascorbate to sustain the cycle. To test this hypothesis, rates of rice nonsymbiotic hemoglobin reduction by ascorbate were measured directly, in the presence and absence of purified rice monodehydroascorbate reductase and NADH. Solution NO scavenging was also measured methodically in the presence and absence of rice nonsymbiotic hemoglobin and monodehydroascorbate reductase, under hypoxic and normoxic conditions, in an effort to gauge the likelihood of these proteins affecting NO metabolism in plant tissues. Our results indicate that ascorbic acid slowly reduces rice nonsymbiotic hemoglobin at a rate identical to myoglobin reduction. The product of the reaction is monodehydroascorbate, which can be efficiently reduced back to ascorbate in the presence of monodehydroascorbate reductase and NADH. However, our NO scavenging results suggest that the direct reduction of plant hemoglobin by ascorbic acid is unlikely to serve as a significant factor in NO metabolism, even in the presence of monodehydroascorbate reductase. Finally, the possibility that the direct reaction of nitrite/nitrous acid and ascorbic acid produces NO was measured at various pH values mimicking hypoxic plant cells. Our results suggest that this reaction is a likely source of NO as the plant cell pH drops below 7, and as nitrite concentrations rise to mM levels during hypoxia. PMID:24376554

  8. NITRITE REDUCTASE ACTIVITY OF NON-SYMBIOTIC HEMOGLOBINS FROM ARABIDOPSIS THALIANA†

    Science.gov (United States)

    Tiso, Mauro; Tejero, Jesús; Kenney, Claire; Frizzell, Sheila; Gladwin, Mark T.

    2013-01-01

    Plant non-symbiotic hemoglobins possess hexa-coordinate heme geometry similar to the heme protein neuroglobin. We recently discovered that deoxygenated neuroglobin converts nitrite to nitric oxide (NO), an important signaling molecule involved in many processes in plants. We sought to determine whether Arabidopsis thaliana non-symbiotic hemoglobins class 1 and 2 (AHb1 and AHb2) might function as nitrite reductases. We found that the reaction of nitrite with deoxygenated AHb1 and AHb2 generates NO gas and iron-nitrosyl-hemoglobin species. The bimolecular rate constants for nitrite reduction to NO are 19.8 ± 3.2 and 4.9 ± 0.2 M−1s−1, at pH = 7.4 and 25°C, respectively. We determined the pH dependence of these bimolecular rate constants and found a linear correlation with the concentration of protons, indicating the requirement for one proton in the reaction. Release of free NO gas during reaction in anoxic and hypoxic (2% oxygen) conditions was confirmed by chemiluminescence detection. These results demonstrate that deoxygenated AHb1 and AHb2 reduce nitrite to form NO via a mechanism analogous to that observed for hemoglobin, myoglobin and neuroglobin. Our findings suggest that during severe hypoxia and in the anaerobic plant roots, especially in water submerged species, non-symbiotic hemoglobins provide a viable pathway for NO generation via nitrite reduction. PMID:22620259

  9. Manganese concentration in the spinal cords and blood corpuscles of amyotrophic lateral sclerosis patients

    Energy Technology Data Exchange (ETDEWEB)

    Miyata, Satoru; Toyoshima, Masanori; Otsuki, Yuzo; Nagata, Hiroshi; Nakamura, Shigenobu (Kyoto Univ. (Japan). Faculty of Medicine)

    1981-11-01

    Manganese concentration in the spinal cord tissues and the blood corpuscles from patients with amyotrophic lateral sclerosis (ALS) and other diseases were measured by neutron activation analysis. The mean manganese concentration in the spinal cord from ALS patients was significantly higher than that from control subjects, especially in the anterior horn of the cervical cord. In order to determine the manganese concentration in blood corpuscles by neutron activation analysis, it was necessary to subtract /sup 56/Mn derived from the /sup 56/Fe(n, p)/sup 56/Mn reaction. The mean Mn concentration in the blood corpuscles from ALS patients seems to be lower than that from patients with other diseases. Fe, Se, Rb and Zn concentrations in the blood corpuscles from ALS patients were not different from those of patients with other diseases.

  10. Manganese concentration in the spinal cords and blood corpuscles of amyotrophic lateral sclerosis patients

    International Nuclear Information System (INIS)

    Miyata, Satoru; Toyoshima, Masanori; Otsuki, Yuzo; Nagata, Hiroshi; Nakamura, Shigenobu

    1981-01-01

    Manganese concentration in the spinal cord tissues and the blood corpuscles from patients with amyotrophic lateral sclerosis (ALS) and other diseases were measured by neutron activation analysis. The mean manganese concentration in the spinal cord from ALS patients was significantly higher than that from control subjects, especially in the anterior horn of the cervical cord. In order to determine the manganese concentration in blood corpuscles by neutron activation analysis, it was necessary to subtract 56 Mn derived from the 56 Fe(n, p) 56 Mn reaction. The mean Mn concentration in the blood corpuscles from ALS patients seems to be lower than that from patients with other diseases. Fe, Se, Rb and Zn concentrations in the blood corpuscles from ALS patients were not different from those of patients with other diseases. (author)

  11. The effect of increased centrifugation temperature on the quality of red-blood-cell concentrates of automated whole blood processing.

    Science.gov (United States)

    Weinigel, C; Rummler, S; Barz, D

    2013-10-01

    There are manual and automated methods to separate whole blood (WB) available. The Atreus whole blood processing system is an automated method, which combines centrifugation and expression of components into a single device. A major difference to conventional methods is that centrifugation temperature is not controlled at 22°C. The aim of this study was to examine the influence of increased centrifugation temperatures on the quality of red-blood-cell concentrates (RCC) after active cooling of WB prior to processing. A total of 28 WB were processed: 16 at centrifugation temperatures of up to 28°C (1st protocol) and 12 at 34°C (2nd protocol). RCC quality parameters were tested weekly for 42 days. Red-blood-cell concentrates (RCC) quality complied with the European and German guidelines. Haemolysis was not significantly different throughout storage. Significant statistical differences were detected between both protocols in potassium concentration at the end of storage and in ATP levels at the day of processing. Centrifugation temperatures of up to 34°C are well tolerated by the red blood cells with minimal interference with the RCC quality parameters. © 2013 International Society of Blood Transfusion.

  12. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  13. Evaluation of anemia on unenhanced CT of the thorax

    International Nuclear Information System (INIS)

    Zhang Yuzhong; Zhang Xuelin; Zhong Qun; Zhang Fan; Zhang Wensheng

    2006-01-01

    Objective: To explore the correlation between CT density of blood in Cardiac Chambers and hemoglobin concentration in blood, and to evaluate the veracity of diagnosis of aneamia on unenhanced computed tomography of the thorax. Methods: Thorax (heart) helical CT was performed in 92 patients. In each case, the CT values of the blood pool in left ventricle and ventricular septum were tested, and the ratio of blood pool/ventricular septum were calculated. The hemoglobin concentration in blood was tested. The correlation among these indexes were analysed. Results: In these factors, CT density of blood was strongly and positively correlated with hemoglobin concentration in blood (r=0.571, P=0.000), and the CT density ratio was also strongly and positively correlated with hemoglobin concentration in blood (r=0.650, P=0.000). It dramatically implies that the patient may be suffering from aneamia when the ratio is Ness than 90% (male) or 87% (female). Conclusion: Blood pool/ventricular septum CT density ratio may be as a reliable indicator for judging and grading aneamia with CT. (authors)

  14. Investigations on the role of hemoglobin in sulfide metabolism by intact human red blood cells.

    Science.gov (United States)

    Bianco, Christopher L; Savitsky, Anton; Feelisch, Martin; Cortese-Krott, Miriam M

    2018-03-01

    In addition to their role as oxygen transporters, red blood cells (RBCs) contribute to cardiovascular homeostasis by regulating nitric oxide (NO) metabolism via interaction of hemoglobin (Hb) with nitrite and NO itself. RBCs were proposed to also participate in sulfide metabolism. Although Hb is known to react with sulfide, sulfide metabolism by intact RBCs has not been characterized so far. Therefore we explored the role of Hb in sulfide metabolism in intact human RBCs. We find that upon exposure of washed RBCs to sulfide, no changes in oxy/deoxyhemoglobin (oxy/deoxyHb) are observed by UV-vis and EPR spectroscopy. However, sulfide reacts with methemoglobin (metHb), forming a methemoglobin-sulfide (metHb-SH) complex. Moreover, while metHb-SH is stable in cell-free systems even in the presence of biologically relevant thiols, it gradually decomposes to produce oxyHb, inorganic polysulfides and thiosulfate in intact cells, as detected by EPR and mass spectrometry. Taken together, our results demonstrate that under physiological conditions RBCs are able to metabolize sulfide via intermediate formation of a metHb-SH complex, which subsequently decomposes to oxyHb. We speculate that decomposition of metHb-SH is preceded by an inner-sphere electron transfer, forming reduced Hb (which binds oxygen to form oxyHb) and thiyl radical (a process we here define as "reductive sulfhydration"), which upon release, gives rise to the oxidized products, thiosulfate and polysulfides. Thus, not only is metHb an efficient scavenger and regulator of sulfide in blood, intracellular sulfide itself may play a role in keeping Hb in the reduced oxygen-binding form and, therefore, be involved in RBC physiology and function. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Variability in blood and blood component utilization as assessed by an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Savage, Will J; Rothschild, Jim A; Rivers, Richard J; Ness, Paul M; Paul, Sharon L; Ulatowski, John A

    2012-07-01

    Data can be collected for various purposes with anesthesia information management systems. The authors describe methods for using data acquired from an anesthesia information management system to assess intraoperative utilization of blood and blood components. Over an 18-month period, data were collected on 48,086 surgical patients at a tertiary care academic medical center. All data were acquired with an automated anesthesia recordkeeping system. Detailed reports were generated for blood and blood component utilization according to surgical service and surgical procedure, and for individual surgeons and anesthesiologists. Transfusion hemoglobin trigger and target concentrations were compared among surgical services and procedures, and between individual medical providers. For all patients given erythrocytes, the mean transfusion hemoglobin trigger was 8.4 ± 1.5, and the target was 10.2 ± 1.5 g/dl. Variation was significant among surgical services (trigger range: 7.5 ± 1.2-9.5 ± 1.1, P = 0.0001; target range: 9.1 ± 1.2-11.3 ± 1.4 g/dl, P = 0.002), surgeons (trigger range: 7.2 ± 0.7-9.8 ± 1.0, P = 0.001; target range: 8.8 ± 0.9-11.8 ± 1.3 g/dl, P = 0.001), and anesthesiologists (trigger range: 7.2 ± 0.8-9.6 ± 1.2, P = 0.001; target range: 9.0 ± 0.9-11.7 ± 1.3 g/dl, P = 0.0004). The use of erythrocyte salvage, fresh frozen plasma, and platelets varied threefold to fourfold among individual surgeons compared with their peers performing the same surgical procedure. The use of data acquired from an anesthesia information management system allowed a detailed analysis of blood component utilization, which revealed significant variation among surgical services and surgical procedures, and among individual anesthesiologists and surgeons compared with their peers. Incorporating these methods of data acquisition and analysis into a blood management program could reduce unnecessary transfusions, an outcome that may increase patient safety and reduce costs.

  16. Comparison of Selected Morphological, Rheological and Biochemical Parameters of Winter Swimmers' Blood at the End of One Winter Swimming Season and at the Beginning of Another.

    Science.gov (United States)

    Teległów, Aneta; Marchewka, Jakub; Tabarowski, Zbigniew; Rembiasz, Konrad; Głodzik, Jacek; Scisłowska-Czarnecka, Anna

    2015-01-01

    The aim of the study was to examine potential differences in the morphological, rheological and biochemical blood parameters of winter swimmers who remained physically active during the period between the end of one winter swimming season and the beginning of another. The study included a group of healthy winter swimmers (n = 17, all between 30 and 60 years of age). Six months following the end of winter season, the levels of mean corpuscular hemoglobin concentration and mean corpuscular hemoglobin turned out to be significantly higher, while erythrocyte count and hematocrit level significantly lower than at the baseline. Moreover, the break in winter swimming was reflected by a significant increase in median erythrocyte elongation index at all shear stress levels ≥ 1.13 Pa. The only significant changes in biochemical parameters of the blood pertained to an increase in the concentration of transferrin and to a decrease in the total protein, albumin and beta-1 globulin concentrations. Seasonal effort of winter swimmers between the end of one winter swimming season and the beginning of another has a positive influence on morphological, rheological and biochemical blood parameters.

  17. Hemoglobin Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... page: https://medlineplus.gov/labtests/hemoglobintest.html Hemoglobin Test To use the sharing features on this page, please enable JavaScript. What is a Hemoglobin Test? A hemoglobin test measures the levels of hemoglobin ...

  18. Detecting Methemoglobinemia in Animals with a Drop of Blood.

    Directory of Open Access Journals (Sweden)

    Toni G Patton

    Full Text Available A major concern during pesticide development and use is the impact on non-target species, such as raptors or domestic cats and dogs. Sodium nitrite and para-aminopropiophenone (PAPP are two toxicants currently being studied for the control of invasive species, such as starlings and feral swine. When given to an animal these compounds oxidize hemoglobin, which renders it unable to carry oxygen resulting in methemoglobinemia. This study developed a method to estimate methemoglobin levels in mammals and birds by examining the efficacy of sodium nitrite to induce the conversion of hemoglobin to methemoglobin. Varying concentrations of sodium nitrite were added to aliquots of coyote, vole, feral swine, starling, and duck blood, collected from captive animals. The blood samples were analyzed spectrophotometrically to determine percent methemoglobin and digitally to determine red color values (RCV associated with different methemoglobin levels. The avian and mammalian blood reached 100% methemoglobin levels at 200 mM and 15 mM sodium nitrite, respectively. All animals had similar RCV for a given percent methemoglobin. In conclusion, this study developed a procedure to quickly determine methemoglobin levels in mammals and birds. Furthermore, percent methemoglobin can be estimated with one standard curve from any animal species and an image of a blood spot. The technique will be useful during field studies, in agricultural areas, or in a veterinarian's office for the rapid diagnosis of methemoglobinemia in non-target animals that have eaten toxicants/baits or baited animals.

  19. The influence of moderate-intensity physical effort on peripheral blood in adults with Down syndrome - a pilot study.

    Science.gov (United States)

    Aleksander-Szymanowicz, P; Marchewka, A; Dabrowski, Z; Teleglow, A; Bac, A; Glodzik, J

    2014-10-01

    The aim of this study was to evaluate the influence of a six-week aerobic training on peripheral blood in adults with Down syndrome. Fifteen men with Down syndrome (average age 22.4 years ± 0.91) with moderate or severe intellectual disability took part in the study. Patients underwent a training program three times a week for six weeks. Venous blood samples of 10 ml were collected from every examined patient, 24 hours before and after the exercise. The blood samples were submitted to hematological examination (hematocrit, fibrinogen, plasma viscosity, red blood cell (RBC) number, RBC indicators: mean corpuscular volume (MCV), mean corpuscular hemoglobin concentration (MCHC), mean corpuscular hemoglobin (MCH)), reduced glutathione (GSH) level and number of macrocytes, polikilocytrometric examination of RBC and rheological blood examination (elongation index (EI), aggregation index (AI), syllectogram amplitude (AMP), aggregation half time (t1/2)) was made by LORCA. Amoderate six-week physical training performed on a cycloergometer resulted in a statistically significant decrease in the MCV value, hematocrit and plasma viscosity. The six-week cycloergometer training caused a statistically significant increase in the GSH level and erythrocyte pliability at a shear stress of 0.58 Pa.

  20. Acute iatrogenic polycythemia induced by massive red blood cell transfusion during subtotal abdominal colectomy

    Directory of Open Access Journals (Sweden)

    David Chiapaikeo

    2015-03-01

    Full Text Available A 46 year old man was transfused ten units of packed red blood cells during subtotal colectomy after intraoperative point-of-care testing values demonstrated hemoglobin values less than seven grams per deciliter (g/dL. A post-operative hemoglobin analyzed in a standard hematologic laboratory revealed a hemoglobin value of 27.8 g/dL. He underwent emergent red blood cell depletion therapy which decreased his hemoglobin to 7.5 g/dL. The physiologic consequences of iatrogenic polycythemia caused by massive transfusion during major abdominal surgery must take into account the fluid shifts that interplay between the osmotic load, viscosity of blood, and postoperative third spacing of fluid. Treatment of acute iatrogenic polycythemia can be effectively accomplished by red blood cell depletion therapy. However, fluid shifts caused by massive transfusion followed by rapid red cell depletion produce a unique physiologic state that is without a well-described algorithm for management.

  1. Regulation of hemoglobin AIc formation in human erythrocytes in vitro. Effects of physiologic factors other than glucose.

    OpenAIRE

    Smith, R J; Koenig, R J; Binnerts, A; Soeldner, J S; Aoki, T T

    1982-01-01

    The formation of hemoglobin AIc was studied in intact human erythrocytes in vitro. Satisfactory methods were developed for maintaining erythrocytes under physiologic conditions for greater than 8 d with less than 10% hemolysis. Hemoglobin AIc levels were determined chromatographically on erythrocyte hemolysates after removal of reversible components by incubation for 6 h at 37 degree C. Hemoglobin AIc concentration was found to increase linearly with time during 8 d of incubation. The rate of...

  2. For People of African, Mediterranean, or Southeast Asian Heritage: Important Information about Diabetes Blood Tests

    Science.gov (United States)

    ... Urodynamic Testing Virtual Colonoscopy Diabetes Blood Tests for People of African, Mediterranean, or Southeast Asian Descent Introduction ... care. What are some common hemoglobin variants? Most people have only one kind of hemoglobin, called hemoglobin ...

  3. The effect of interior lead hazard controls on children's blood lead concentrations: a systematic evaluation.

    Science.gov (United States)

    Haynes, Erin; Lanphear, Bruce P; Tohn, Ellen; Farr, Nick; Rhoads, George G

    2002-01-01

    Dust control is often recommended to prevent children's exposure to residential lead hazards, but the effect of these controls on children's blood lead concentrations is uncertain. We conducted a systematic review of randomized, controlled trials of low-cost, lead hazard control interventions to determine the effect of lead hazard control on children's blood lead concentration. Four trials met the inclusion criteria. We examined mean blood lead concentration and elevated blood lead concentrations (> or = 10 microg/dL, > or = 15 microg/dL, and > or = 20 microg/dL) and found no significant differences in mean change in blood lead concentration for children by random group assignment (children assigned to the intervention group compared with those assigned to the control group). We found no significant difference between the intervention and control groups in the percentage of children with blood lead > or = 10 microg/dL, 29% versus 32% [odds ratio (OR), 0.85; 95% confidence interval (CI), 0.56-1.3], but there was a significant difference in the percentage of children with blood lead > or = 15 microg/dL between the intervention and control groups, 6% versus 14% (OR, 0.40; 95% CI, 0.21-0.80) and in the percentage of children with blood lead > or = 20 microg/dL between the intervention and control groups, 2% versus 6% (OR, 0.29; 95% CI, 0.10-0.85). We conclude that although low-cost, interior lead hazard control was associated with 50% or greater reduction in the proportion of children who had blood lead concentrations exceeding 15 microg/dL and > or = 20 microg/dL, there was no substantial effect on mean blood lead concentration.

  4. Topical versus intravenous tranexamic acid as a blood conservation intervention for reduction of post-operative bleeding in hemiarthroplasty.

    Science.gov (United States)

    Emara, Walid Mohamed; Moez, Khaled K; Elkhouly, Abeer H

    2014-01-01

    This study was performed to test the effectiveness of topical tranexamic acid (TXA) in reducing blood loss in pelvic hemiarthoplasty surgeries compared with intravenous TXA, regarding the incidence of thromboembolic complications (deep vein thrombosis [DVT], pulmonary embolism (PE) and cerebrovascular stroke [CVS]). After obtaining institutional ethical approval 60 patients divided into three groups. Group A: Received intravenous TXA Group B: Received topical TXA Group C: Control group (placebo saline). All patients were received general anesthesia and post-operative bleeding, immediate and 24 h post-operatively, hemoglobin concentration, hematocrit, platelets and coagulation profile (prothrombin time, activated partial thromboplastin time and international normalized ratio) baseline, immediate and 24 h post-operatively. Thromboelastography was recorded baseline, immediate and 24 h post-operatively. Incidence of DVT, PE and CVS was recorded. There was statistical significant elevation hemoglobin concentration and hematocrit in both Groups A and B, significant increase in blood loss in Group C, significant increase in number of patients receiving blood in Group C, there was a significant decrease in "r" and "k" times and a significant increase in maximum amplitude and α-angle in Group A, statistically significant increase in the incidence of thromboembolic events in the form of DVT, PE and CVS in Group A. Topical TXA is effective in decreasing post-operative blood loss with possible side-effects of this route of administration.

  5. Blood doping and its detection.

    Science.gov (United States)

    Jelkmann, Wolfgang; Lundby, Carsten

    2011-09-01

    Hemoglobin mass is a key factor for maximal exercise capacity. Some athletes apply prohibited techniques and substances with intent to increase hemoglobin mass and physical performance, and this is often difficult to prove directly. Autologous red blood cell transfusion cannot be traced on reinfusion, and also recombinant erythropoietic proteins are detectable only within a certain timeframe. Novel erythropoietic substances, such as mimetics of erythropoietin (Epo) and activators of the Epo gene, may soon enter the sports scene. In addition, Epo gene transfer maneuvers are imaginable. Effective since December 2009, the World Anti-Doping Agency has therefore implemented "Athlete Biologic Passport Operating Guidelines," which are based on the monitoring of several parameters for mature red blood cells and reticulocytes. Blood doping may be assumed, when these parameters change in a nonphysiologic way. Hematologists should be familiar with blood doping practices as they may play an important role in evaluating blood profiles of athletes with respect to manipulations, as contrasted with the established diagnosis of clinical disorders and genetic variations.

  6. A new hemoglobin gene from soybean: a role for hemoglobin in all plants

    DEFF Research Database (Denmark)

    Anderson, C R; Jensen, E O; LLewellyn, D J

    1996-01-01

    We have isolated a new hemoglobin gene from soybean. It is expressed in cotyledons, stems of seedlings, roots, young leaves, and in some cells in the nodules that are associated with the nitrogen-fixing Bradyrhizobium symbiont. This contrasts with the expression of the leghemoglobins, which...... are active only in the infected cells of the nodules. The deduced protein sequence of the new gene shows only 58% similarity to one of the soybean leghemoglobins, but 85-87% similarity to hemoglobins from the nonlegumes Parasponia, Casuarina, and barley. The pattern of expression and the gene sequence...... indicate that this new gene is a nonsymbiotic legume hemoglobin. The finding of this gene in legumes and similar genes in other species strengthens our previous suggestion that genomes of all plants contain hemoglobin genes. The specialized leghemoglobin gene family may have arisen from a preexisting...

  7. Development of a Synthetic Blood Substitute Utilizing Hemoglobin Vesicles.

    Science.gov (United States)

    1992-02-26

    adequately restored. The most widely used blood replacement therapy is the transfusion of whole blood or blood components. Problems associated with these...Hydrogenated Soy-PC was obtained from the American Lecithin Co. (Atlanta, GA) and hydrogenated Egg-PC (IV-40) was supplied by Liposome Technology Inc. (Menlo...Grcssweiner, "Light Dosimetry Model for Phctodvnamic Therapy Treatment Planning," Lasers Surg. Med. 11, 165-173 (1991). 22. P. Parsa. S. L. Jacques, and N

  8. Moessbauer studies of hemoglobin in erythrocytes exposed to neutron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Niemiec, Katarzyna; Kaczmarska, Magdalena; Buczkowski, Mateusz [AGH University, Faculty of Physics and Computer Science, Department of Medical Physics and Biophysics (Poland); Fornal, Maria [Collegium Medicum, Jagiellonian University, Department of Internal Medicine and Gerontology (Poland); Pohorecki, Wladyslaw [AGH University, Faculty of Energy and Fuels (Poland); Matlak, Krzysztof; Korecki, Jozef [AGH University, Faculty of Physics and Computer Science, Department of Solid State Physics (Poland); Grodzicki, Tomasz [Collegium Medicum, Jagiellonian University, Department of Internal Medicine and Gerontology (Poland); Burda, Kvetoslava, E-mail: kvetoslava.burda@fis.agh.edu.pl [AGH University, Faculty of Physics and Computer Science, Department of Medical Physics and Biophysics (Poland)

    2012-03-15

    We studied radiation effects on the stability of various states of hemoglobin (Hb) in red blood cells (RBC) irradiated with a very low dose of neutron rays, 50 {mu}Gy. We investigated RBCs isolated from blood of healthy donors. Moessbauer spectroscopy was applied to monitor different forms of Hb. Our results show, for the first time, that oxyhemoglobin (OxyHb) and deoxyhemoglobin (DeoxyHb) are two Hb forms sensitive to such a low neutron radiation. Both Hbs change into a new Hb form (Hb{sub irr}). Additionally, OxyHb transfers into HbOH/H{sub 2}O, which under our experimental conditions is resistant to the action of neutron rays.

  9. Hemoglobin Expression in Nonerythroid Cells: Novel or Ubiquitous?

    Directory of Open Access Journals (Sweden)

    Debarchana Saha

    2014-01-01

    Full Text Available Hemoglobin (Hb is a major protein involved in transport of oxygen (O2. Red blood cells (RBCs contain maximum amount of Hb and because of their unique structure and plasticity they transport O2 to various tissues of the body at an optimal concentration. Recently, it has been reported that, apart from RBCs, Hb is also expressed by nonerythroid cells such as epithelial cells of different origin. The cells expressing Hb are from the tissues where maintenance of O2 homeostasis is of paramount importance. Hb expression has been observed in the epithelial cells from human tissues including lungs, neurons, retina, and endometrium. Our group has recently demonstrated that Hb is expressed by the cervicovaginal epithelial cells. We further showed that, apart from maintaining O2 homeostasis, Hb and the peptides derived from it play an indispensable role in the protection of vaginal epithelium by exhibiting antimicrobial activity. In this review, we discuss the significance of Hb expression in vaginal epithelial cells and its role in the recognition of pathogens thereby reducing the risk and/or severity of inflammation and/or infections and the possible mechanism by which Hb exhibits antimicrobial and antioxidative functions.

  10. Consumption of lead-shot cervid meat and blood lead concentrations in a group of adult Norwegians.

    Science.gov (United States)

    Meltzer, H M; Dahl, H; Brantsæter, A L; Birgisdottir, B E; Knutsen, H K; Bernhoft, A; Oftedal, B; Lande, U S; Alexander, J; Haugen, M; Ydersbond, T A

    2013-11-01

    Several recent investigations have reported high concentrations of lead in samples of minced cervid meat. This paper describes findings from a Norwegian study performed in 2012 among 147 adults with a wide range of cervid game consumption. The main aim was to assess whether high consumption of lead-shot cervid meat is associated with increased concentration of lead in blood. A second aim was to investigate to what extent factors apart from game consumption explain observed variability in blood lead levels. Median (5 and 95 percentile) blood concentration of lead was 16.6 µg/L (7.5 and 39 µg/L). An optimal multivariate linear regression model for log-transformed blood lead indicated that cervid game meat consumption once a month or more was associated with approximately 31% increase in blood lead concentrations. The increase seemed to be mostly associated with consumption of minced cervid meat, particularly purchased minced meat. However, many participants with high and long-lasting game meat intake had low blood lead concentrations. Cervid meat together with number of bullet shots per year, years with game consumption, self-assembly of bullets, wine consumption and smoking jointly accounted for approximately 25% of the variation in blood lead concentrations, while age and sex accounted for 27% of the variance. Blood lead concentrations increased approximately 18% per decade of age, and men had on average 30% higher blood lead concentrations than women. Hunters who assembled their own ammunition had 52% higher blood lead concentrations than persons not making ammunition. In conjunction with minced cervid meat, wine intake was significantly associated with increased blood lead. Our results indicate that hunting practices such as use of lead-based ammunition, self-assembling of lead containing bullets and inclusion of lead-contaminated meat for mincing to a large extent determine the exposure to lead from cervid game consumption. © 2013 Elsevier Inc. All rights

  11. The effect of gamma-rays on the hemoglobin of whole-body irradiated mice

    International Nuclear Information System (INIS)

    Ashry, H.A.; Selim, N.S.; El-Behay, A.Z.

    1994-01-01

    Changes in the UV-visible absorption spectrum of mouse hemoglobin as a result of whole body irradiation were studied. White albino adult mice were exposed to a Cs-137 γ-source at a dose rate of 47.5 Gy/h to different absorbed dose values ranging from 1 to 8 Gy. Blood specimens were taken 24 h after irradiation. The UV-visible absorption spectra of hemoglobin of irradiated and control mice were measured in the wavelength range from 200 to 700 nm. The obtained results showed significant changes in the bands measured at 340 nm, in the Soret band measured at 410 nm, also, the α- and β-bands measured at 537 and 572 nm showed significant decrease in intensity with the absorbed dose increase. The absorbance measured at 630 nm showed no significant changes. The radiation effect on the animal hemoglobin was discussed on the basis of the obtained results. (Author)

  12. TRUNCATED OR 2/2 HEMOGLOBINS : A NEW CLASS OF GLOBINS WITH NOVEL STRUCTURE AND FUNCTION

    Directory of Open Access Journals (Sweden)

    Amit Kumar

    2013-06-01

    Full Text Available Bright red hemoglobins, the most well-known paradigm in protein science, seem to be ubiquitous in nature. With advances in modern tools and techniques, discovery of new globins at a rapid pace has expanded this family. With every discovery, new insights emerged regarding their novel structure, function and several other characteristics previously not observed for hemoglobins. Even the classical function unanimously assigned to hemoglobins – oxygen transport and storage – needed re-evaluation. The ability of this class of proteins to show responses against various gaseous ligands, even the poisonous ones, indicate that it is obviously as ancient as life. As organisms evolved, hemoglobins also evolved, and accumulated a great degree of diversity in all aspects. The classical globin fold is very unique with 3-on-3 alpha helical bundle as observed in the traditional oxygen-transport hemoglobins like myoglobin, human blood hemoglobin and leghemoglobins in plants. However, a class of the newly discovered hemoglobins, which dominate the superfamily and appears ancient in origin mostly have 2-on-2 fold, commonly termed as “truncated” hemoglobins. These hemoglobins are phylogenetically distinct from their classical counterparts and are often shorter in their polypeptide length by 20-40 residues mainly due to a lack of short A helix, D helix and F helix. However, hemoglobins with 2-on-2 fold were also later found to have polypeptide chain lengths similar in size to classical globins. Disordered pre-F helix region, conserved glycine motifs and other key residues and apolar tunnels through their protein matrix for migration of ligands are some unique characteristics features of these truncated hemoglobins. Some of these are also hexacoordinated at heme iron where an amino acid from within the protein coordinates heme iron in absence of a ligand. These hemoglobins are well known for their high affinity towards ligand and have a diverse mechanism of

  13. Non-invasive hemoglobin monitoring.

    Science.gov (United States)

    Joseph, Bellal; Haider, Ansab; Rhee, Peter

    2016-09-01

    Technology has transformed the practice of medicine and surgery in particular over the last several decades. This change in practice has allowed diagnostic and therapeutic tests to be performed less invasively. Hemoglobin monitoring remains one of the most commonly performed diagnostic tests in the United States. Recently, non-invasive hemoglobin monitoring technology has gained popularity. The aim of this article is to review the principles of how this technology works, pros and cons, and the implications of non-invasive hemoglobin technology particularly in trauma surgery. Copyright © 2015 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  14. Blood harmane concentrations and dietary protein consumption in essential tremor.

    Science.gov (United States)

    Louis, E D; Zheng, W; Applegate, L; Shi, L; Factor-Litvak, P

    2005-08-09

    Beta-carboline alkaloids (e.g., harmane) are highly tremorogenic chemicals. Animal protein (meat) is the major dietary source of these alkaloids. The authors previously demonstrated that blood harmane concentrations were elevated in patients with essential tremor (ET) vs controls. Whether this difference is due to greater animal protein consumption by patients or their failure to metabolize harmane is unknown. The aim of this study was to determine whether patients with ET and controls differ with regard to 1) daily animal protein consumption and 2) the correlation between animal protein consumption and blood harmane concentration. Data on current diet were collected with a semiquantitative food frequency questionnaire and daily calories and consumption of animal protein and other food types was calculated. Blood harmane concentrations were log-transformed (logHA). The mean logHA was higher in 106 patients than 161 controls (0.61 +/- 0.67 vs 0.43 +/- 0.72 g(-10)/mL, p = 0.035). Patients and controls consumed similar amounts of animal protein (50.2 +/- 19.6 vs 49.4 +/- 19.1 g/day, p = 0.74) and other food types (animal fat, carbohydrates, vegetable fat) and had similar caloric intakes. In controls, logHA was correlated with daily consumption of animal protein (r = 0.24, p = 0.003); in patients, there was no such correlation (r = -0.003, p = 0.98). The similarity between patients and controls in daily animal protein consumption and the absence of the normal correlation between daily animal protein consumption and logHA in patients suggests that another factor (e.g., a metabolic defect) may be increasing blood harmane concentration in patients.

  15. Carbohydrate ingestion before and during soccer match play and blood glucose and lactate concentrations.

    Science.gov (United States)

    Russell, Mark; Benton, David; Kingsley, Michael

    2014-01-01

    The ingestion of carbohydrate (CHO) before and during exercise and at halftime is commonly recommended to soccer players for maintaining blood glucose concentrations throughout match play. However, an exercise-induced rebound glycemic response has been observed in the early stages of the second half of simulated soccer-specific exercise when CHO-electrolyte beverages were consumed regularly. Therefore, the metabolic effects of CHO beverage consumption throughout soccer match play remain unclear. To investigate the blood glucose and blood lactate responses to CHOs ingested before and during soccer match play. Crossover study. Applied research study. Ten male outfield academy soccer players (age = 15.6 ± 0.2 years, height = 1.74 ± 0.02 m, mass = 65.3 ± 1.9 kg, estimated maximal oxygen consumption = 58.4 ± 0.8 mL·kg(-1)·min(-1)). Players received a 6% CHO-electrolyte solution or an electrolyte (placebo) solution 2 hours before kickoff, before each half (within 10 minutes), and every 15 minutes throughout exercise. Blood samples were obtained at rest, every 15 minutes during the match (first half: 0-15, 15-30, and 30-45 minutes; second half: 45-60, 60-75, and 75-90 minutes) and 10 minutes into the halftime break. Metabolic responses (blood glucose and blood lactate concentrations) and markers of exercise intensity (heart rate) were recorded. Supplementation influenced the blood glucose response to exercise (time × treatment interaction effect: P ≤ .05), such that glucose concentrations were higher at 30 to 45 minutes in the CHO than in the placebo condition. However, in the second half, blood glucose concentrations were similar between conditions because of transient reductions from peak values occurring in both trials at halftime. Blood lactate concentrations were elevated above those at rest in the first 15 minutes of exercise (time-of-sample effect: P interaction effect: P = .49). Ingestion of a 6% CHO-electrolyte beverage before and during soccer match

  16. [Study of blood concentration analysis for formate in acute methanol poisoning].

    Science.gov (United States)

    Morikawa, Go; Okazawa, Katsuko; Shimizu, Takahiro; Otagiri, Sayoko; Fuwa, Fumiko; Nakagawa, Saori; Yamato, Susumu

    2015-09-01

    A 53-year-old woman ingested about 300 mL of 95% methanol. After immediate ethanol antagonist therapy and hemodialysis, she recovered completely. Few days later, the plasma concentration of methanol and formate was measured. A gas chromatography was used for the plasma methanol concentration measurement, and a colorimetric method was used for plasma formate concentration measurement (Formate Colorimetric Assay Kit; BioVision, California, USA). Patient's plasma methanol concentration before hemodialysis was 676.9 mg/dL and plasma formate concentration was 16.9 mg/dL. By removing blood methanol and formate using hemodialysis before formate accumulations in the body, the patient was discharged without any sequelae. We were able to obtain correlation between a gas chromatography and colorimetric method without gas chromatography-mass spectrometry, with good correlation coefficients. The sensitivity was sufficient for analyzing blood sample. Monitoring formate concentration is useful in determining the treatment and evaluating the prognosis of methanol poisoning. We suggest that this colorimetric method is useful in a facility with no access to a gas chromatography in order to measure a plasma formate concentration.

  17. Extramedullary hematopoiesis and paraplegia in a patient with hemoglobin e-Beta thalassemia.

    Science.gov (United States)

    Alam, M R; Habib, M S; Dhakal, G P; Khan, M R; Rahim, M A; Chowdhury, A J; Mahmud, T K

    2010-07-01

    Extramedullary hematopoiesis (EMH) occurs in patients with various hematologic disorders involving a chronic increase in the production of red blood cells, and is often associated polycythemia vera and sickle cell anaemia, but is less common with thalassemia especially with hemoglobin E-beta thalassemia. Spinal cord compression due to EMH is a extremely rare complication of thalassemia and may present with paraparesis or paraplegia with or without sensory impairment. Treatment options mostly include surgery and/or radiotherapy. Whereas cases presenting with paraplegia have been treated with either surgery or radiotherapy with equal frequency and efficacy, almost all reported cases with paraplegia have been treated with surgery with or without radiation therapy. We hereby report a case of hemoglobin E-beta thalassemia with paraplegia treated successfully with radiotherapy.

  18. Empirical modelling to predict the refractive index of human blood

    International Nuclear Information System (INIS)

    Yahya, M; Saghir, M Z

    2016-01-01

    Optical techniques used for the measurement of the optical properties of blood are of great interest in clinical diagnostics. Blood analysis is a routine procedure used in medical diagnostics to confirm a patient’s condition. Measuring the optical properties of blood is difficult due to the non-homogenous nature of the blood itself. In addition, there is a lot of variation in the refractive indices reported in the literature. These are the reasons that motivated the researchers to develop a mathematical model that can be used to predict the refractive index of human blood as a function of concentration, temperature and wavelength. The experimental measurements were conducted on mimicking phantom hemoglobin samples using the Abbemat Refractometer. The results analysis revealed a linear relationship between the refractive index and concentration as well as temperature, and a non-linear relationship between refractive index and wavelength. These results are in agreement with those found in the literature. In addition, a new formula was developed based on empirical modelling which suggests that temperature and wavelength coefficients be added to the Barer formula. The verification of this correlation confirmed its ability to determine refractive index and/or blood hematocrit values with appropriate clinical accuracy. (paper)

  19. Hemoglobin proteolysis in blood-feeding ticks: mapping of multienzyme cascade by functional proteomics

    Czech Academy of Sciences Publication Activity Database

    Horn, Martin; Nussbaumerová, Martina; Šanda, Miloslav; Kovářová, Z.; Srba, J.; Franta, Zdeněk; Sojka, Daniel; Kopáček, Petr; Mareš, Michael

    2009-01-01

    Roč. 276, Suppl. 1 (2009), s. 314-314 ISSN 1742-464X. [FEBS Congress /34/. 04.07.2009-09.07.2009, Praha] R&D Projects: GA MŠk(CZ) LC06009; GA ČR GA203/09/1585; GA AV ČR IAA600960910 Institutional research plan: CEZ:AV0Z40550506; CEZ:AV0Z60220518 Keywords : hemoglobin olysis * tick digestion * Ixodes ricinus Subject RIV: CE - Biochemistry

  20. Precision of a new bedside method for estimation of the circulating blood volume

    DEFF Research Database (Denmark)

    Christensen, P; Eriksen, B; Henneberg, S W

    1993-01-01

    The present study is a theoretical and experimental evaluation of a modification of the carbon monoxide method for estimation of the circulating blood volume (CBV) with respect to the precision of the method. The CBV was determined from measurements of the CO-saturation of hemoglobin before and a......, determination of CBV can be performed with an amount of CO that gives rise to a harmless increase in the carboxyhemoglobin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)...