  1. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior st

  2. The utility of blood glucose meters in biotechnological applications.

    Science.gov (United States)

    FitzGerald, Jennifer; Vermerris, Wilfred

    2005-06-01

    Most methods used to measure glucose concentrations in biotechnological settings are labour-intensive and/or expensive. With this in mind we have investigated the possibility of employing blood glucose meters, the use of which has the benefit of being fast, convenient and inexpensive, for this purpose. Accu-Chek Advantage (Roche Diagnostics, Indianapolis, IN, U.S.A.) and Precision QID (Medisense, Abbott Laboratories, Indianapolis, IN, U.S.A.) meters were tested using glucose samples of known concentration, at pH 7.5 and 4.8. The Accu-Chek Advantage meter uses strips containing the enzyme glucose dehydrogenase. This meter showed a linear response for glucose concentrations between 0.50 and 6.0 g/litre, and the effect of pH was small. The Precision QID meter uses strips containing the enzyme glucose oxidase and is more sensitive to pH. The displayed glucose concentrations at low pH values were consistently lower than at higher pH values. At both pH values the response curve reached a plateau, which limited the effective range of this meter to a range of 0.30-2.5 g/litre. Unlike the Precision QID meter, the Accu-Chek Advantage meter also responded to xylose and arabinose. A synergistic effect of combining sugars was observed when a mixture of sugars consisting of glucose and arabinose, or glucose and xylose, was applied: the displayed concentrations were consistently higher than was expected on the basis of the individual calibration curves. The use of glucose meters is a fast and convenient alternative to existing methods and may be of particular use for screening purposes where a high degree of accuracy is not crucial. The choice of meter should depend on the application, and in this respect the pH, expected concentration range and the presence of other sugars are among the factors that should be considered.

  3. Multicentric evaluation of eight glucose and four ketone blood meters.

    Science.gov (United States)

    Guimont, Marie-Christine; Desjobert, Hélène; Fonfrède, Michèle; Vitoux, Dominique; Benoist, Jean-Francois; Launay, Jean-Marie; Peoc'h, Katell; Lefèvre, Guillaume

    2015-12-01

    High precision meters for blood glycemia are mandatory for monitoring glucose status in patients, avoiding both hypo- and hyper-glycemia. Health care providers routinely used in both out- and in-patients point-of-care measurements of glucose and ketone. These measurements, frequently used for medical decisions, are known to be less accurate than those performed in laboratories. Our aim was to evaluate, within the frame of an Assistance Publique-Hôpitaux de Paris (AP-HP) multicentric study, the performances of eight glucose and four ketone meters, either connected or non-connected to a laboratory software. Glucose meter accuracy, precision, correlation with plasma glucose determined in central laboratories and hematocrit interferences were determined according to the ISO 15197:2003 norm. The same norm was applied for the determination of accuracy, precision and recovery of ketone meters for B-hydroxybutyrate measurements. Among those meters, seven were considered as acceptable for glucose measurement and two for ketone measurement. Since all meters do not fit clinically relevant criteria, meters' performances have to be evaluated before use in clinical practice. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Your Glucose Meter

    Science.gov (United States)

    ... Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco ... Tips for Testing Your Blood Sugar and Caring for Your Meter Glucose meters test and record how much sugar (called glucose) is in your ...

  5. A Simple Laboratory Experiment to Determine the Kinetics of Mutarotation of D-Glucose Using a Blood Glucose Meter

    Science.gov (United States)

    Perles, Carlos E.; Volpe, Pedro L. O.

    2008-01-01

    A simple commercial blood glucose meter is used to follow the kinetics of mutarotation of D-glucose in aqueous solution. The results may be compared with those obtained using an automatic polarimeter, if this is available This experiment is proposed for use by students in a general chemistry, biology, organic chemistry, and physical chemistry…

  6. Blood Glucose Meters Employing Dynamic Electrochemistry Are Stable against Hematocrit Interference in a Laboratory Setting

    Science.gov (United States)

    Pfützner, Andreas; Musholt, Petra B.; Schipper, Christina; Demircik, Filiz; Hengesbach, Carina; Flacke, Frank; Sieber, Jochen; Forst, Thomas

    2013-01-01

    Background Hematocrit (HCT) is known to be a confounding factor that interferes with many blood glucose (BG) measurement technologies, resulting in wrong readings. Dynamic electrochemistry has been identified as one possible way to correct for these potential deviations. The purpose of this laboratory investigation was to assess the HCT stability of four BG meters known to employ dynamic electrochemistry (BGStar and iBGStar, Sanofi; Wavesense Jazz, AgaMatrix; Wellion Linus, MedTrust) in comparison with three other devices (GlucoDock, Medisana; OneTouch Verio Pro, LifeScan; FreeStyle Freedom InsuLinx, Abbott-Medisense). Methods Venous heparinized blood was immediately aliquoted after draw and manipulated to contain three different BG concentrations (60–90, 130–160, and 280–320 mg/dl) and five different HCT levels (25%, 35%, 45%, 55%, and 60%). After careful oxygenation to normal blood oxygen pressure, each of the resulting 15 different samples was measured six times with three devices and three strip lots of each meter. The YSI Stat 2300 served as laboratory reference method. Stability to HCT influence was assumed when less than 10% difference occurred between the highest and lowest mean glucose deviations in relation to HCT concentrations [hematocrit interference factor (HIF)]. Results Five of the investigated self-test meters showed a stable performance with the different HCT levels tested in this investigation: BGStar (HIF 4.6%), iBGStar (6.6%), Wavesense Jazz (4.1%), Wellion Linus (8.5%), and OneTouch Verio Pro (6.2%). The two other meters were influenced by HCT (FreeStyle InsuLinx 17.8%; GlucoDock 46.5%). Conclusions In this study, meters employing dynamic electrochemistry, as used in the BGStar and iBGStar devices, were shown to correct for potential HCT influence on the meter results. Dynamic electrochemistry appears to be an effective way to handle this interfering condition. PMID:24351179

  7. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  8. Evaluation of newly developed veterinary portable blood glucose meter with hematocrit correction in dogs and cats.

    Science.gov (United States)

    Mori, Akihiro; Oda, Hitomi; Onozawa, Eri; Shono, Saori; Sako, Toshinori

    2017-08-18

    This study evaluated the accuracy of a newly developed veterinary portable blood glucose meter (PBGM) with hematocrit correction in dogs and cats. Sixty-one dogs and 31 cats were used for the current study. Blood samples were obtained from each dog and cat one to six times. Acceptable results were obtained in error grid analysis between PBGM and reference method values (glucose oxidation methods) in both dogs and cats. Bland-Altman plot analysis revealed a mean difference between the PBGM value and reference method value of -1.975 mg/dl (bias) in dogs and 1.339 mg/dl (bias) in cats. Hematocrit values did not affect the results of the veterinary PBGM. Therefore, this veterinary PBGM is clinically useful in dogs and cats.

  9. Cost effectiveness and cost utility of the noncoding blood glucose meter CONTOUR® TS

    Directory of Open Access Journals (Sweden)

    Przemyslaw Holko

    2011-02-01

    Full Text Available Przemyslaw Holko, Pawal KawalecHTA Centre, Kraków, PolandAims: This study assessed the cost efficacy and cost utility of the automatic blood glucose meter CONTOUR® TS from the public payer (National Health Fund [NHF] and payer (patient and NHF perspectives over a 26-year analysis horizon.Methods: Clinical effectiveness data were obtained from prior clinical studies of automatic versus manually coded blood glucose meters. Cost data were obtained from the NHF. The probability of procedure use related to diabetic complications was obtained from four medical centers in Poland. The incremental cost-effectiveness ratio related to 1 life year gained and the incremental cost-utility ratio related to 1 quality-adjusted life year gained were calculated.Results: Assuming co-funding from public funds, introduction of the CONTOUR® TS is associated with savings of Polish złoty (PLN 31,846.19 (€8916.93 and PLN 113,018.19 (€31,645.09 per life year gained from the payer and public payer perspectives, respectively. Cost utility analyses showed that the CONTOUR® TS is associated with savings of PLN 40,465.59 (€11,330.37 and PLN 11,434.82 (€3201.75 per quality-adjusted life year gained from the payer and the public payer perspectives, respectively.Conclusion: The CONTOUR® TS appears superior to manually coded meters available in Poland both from the payer and the public payer perspectives and may represent an improved strategy for glycemic control.Keywords: blood glucose self monitoring, costs and cost analysis, health care costs, diabetes mellitus, diabetes complications 

  10. ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine.

    Science.gov (United States)

    Gerber, Karen L; Freeman, Kathleen P

    2016-03-01

    Portable blood glucose meters (PBGM, glucometers) are a convenient, cost effective, and quick means to assess patient blood glucose concentration. The number of commercially available PBGM is constantly increasing, making it challenging to determine whether certain glucometers may have benefits over others for veterinary testing. The challenge in selection of an appropriate glucometer from a quality perspective is compounded by the variety of analytic methods used to quantify glucose concentrations and disparate statistical analysis in many published studies. These guidelines were developed as part of the ASVCP QALS committee response to establish recommendations to improve the quality of testing using point-of-care testing (POCT) handheld and benchtop devices in veterinary medicine. They are intended for clinical pathologists and laboratory professionals to provide them with background knowledge and specific recommendations for quality assurance (QA) and quality control (QC), and to serve as a resource to assist the provision of advice to veterinarians and technicians to improve the quality of results obtained when using PBGM. These guidelines are not intended to be all-inclusive; rather they provide a minimum standard for management of PBGM in the veterinary setting.

  11. Patient and healthcare professional satisfaction with a new, high accuracy blood glucose meter with color range indicator and wireless connectivity.

    Science.gov (United States)

    Katz, Laurence B; Grady, Mike; Stewart, Lorna; Cameron, Hilary

    2016-07-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. The OneTouch VerioFlex(™) (OTVF) blood glucose monitoring system (BGMS) was evaluated for accuracy in a clinical setting. Patients also used OTVF for a 1-wk trial period and reported their level of satisfaction with meter features. In a separate study, healthcare professionals used an on-line simulator of the BGMS and answered questions about its potential utility to their patients. OTVF was accurate over a wide glucose range and met lay user and system accuracy blood glucose standards described in ISO15197:2013 as well as the accuracy requirements to fulfill US FDA expectations for 510(k) clearance of BGMS. Patients and healthcare professionals felt the features of OTVF, which has the capability to connect wirelessly to mobile devices and interact wirelessly with diabetes management software, could provide significant benefits to them or their patients.

  12. Effects of Different Blood Sampling Methods on Value of Blood Glucose Measured by Rapid Blood Glucose Meter%采血方法对快速血糖测定仪测量值的影响

    Institute of Scientific and Technical Information of China (English)

    赵东荣

    2015-01-01

    目的:探讨不同采血方法对快速血糖测定仪测量值的影响。方法通过对60例糖尿病患者采用3种不同的采血方法,即自然流出法、热水热敷按摩法和手指挤血法,进行末梢血糖浓度的快速测定,同时利用大型生化分析仪测定其静脉血血糖浓度。结果自然流出法测定血糖值和静脉血糖值比较差异无统计学意义(P>0.05),热水热敷按摩和手指挤血法测定血糖值均显著低于静脉血糖值,差异均有统计学意义(P<0.05)。结论临床上使用快速血糖仪检测血糖值时,为保证结果的准确性,宜采用自然流出法采取末梢血。%ObjectiveTo assess the inlfuence of different methods of blood sampling on the results tested by rapid blood glucose meter.Methods Blood glucose of 60 patients with diabetes were tested by rapid blood glucose meter through 3 different methods of blood sampling, and compared with the value of blood glucose measured by taking glucose oxidation enzyme from venous blood.Results There was no statistical signiifcance in value of blood glucose between natural effusion group and venous blood (P>0.05). The values of blood glucose in hot water massage group and finger squeezing group were remarkably lower than those in venous blood group (P<0.05).Conclusion The natural blood out flow of fingers is the better way when value of blood glucose measured by rapid blood glucose meter in clinic.

  13. Comparison of Blood Glucose Values Using Two Glucose Meters and Standard Laboratory Method in Hospitalized Patients in a Teaching Hospital

    Directory of Open Access Journals (Sweden)

    Shima Aghakachoei

    2015-10-01

    Full Text Available Background: Diabetes mellitus is a chronic disease with a worldwide prevalence and its complications can be prevented with close monitoring of blood glucose. Quality of blood glucose monitoring utilizing glucometers in Iranian hospitalized patients has not been well published in the literature. We evaluated the accuracy and consistency of the results of two devices compared with the standard laboratory method used for measuring glucose levels in a teaching hospital.Methods: In this study 100 patients with the average age of 57.5 ±17.7 years were randomly selected from 19 wards and their blood glucose were simultaneously measured using Accu-Chek Active®(1 and Cleverchek®(2 (commonly used in the wards and the conventional laboratory method. Calibration was performed on both devices.Results: Absolute Mean Difference of the devices 1 and 2 from the laboratory values were 24.3±2.4,and 38.5±4.5, respectively (P: 0.003. Correlation coefficient of the obtained values by glucometers1 and 2 with lab, were 0.82 and 0.52, respectively. Calibration of the devices showed that device 1 was the most consistent device with the laboratory values, and Pearson correlation coefficient between the obtained values as a result of four reiterations for each sample in each device showed that the highest coefficient belonged to the device 1 and the least belonged to the device 2 used in the Ear, Nose, and Throat Departments.Conclusion: The device 2 used in different wards of the hospital must be calibrated periodically. Furthermore, the device 1 generated closest results to the ones obtained through the laboratory.

  14. Detection accuracy of three glucose meters estimated by capillary blood glucose measurements compared with venous blood evaluated by the diabetes unit of the Hospital Evangélico de Curitiba, Brazil

    Directory of Open Access Journals (Sweden)

    Camacho SL

    2012-05-01

    Full Text Available Mirnaluci Paulino Ribeiro Gama, Camile Fiorese Cruzeta, Ana Carolina Ossowski, Marina Rech Bay, Mariella Muller Michaelis, Stênio Lujan CamachoEndocrinology and Diabetes Service, Hospital Universitário Evangélico de Curitiba, BrazilObjective: To compare capillary blood glucose measurements between three different glucose meters and with the serum glucose values of inpatients at the diabetes unit of Hospital Universitário Evangélico de Curitiba, Brazil.Materials and methods: A total of 132 non-intensive care unit patients admitted for medical and surgical pathologies were evaluated. All patients reported a previous diagnosis of diabetes mellitus, were under 60 years of age, had no hematocrit alterations, remained hemodynamically stable during the time of data collection, and were given no ascorbic acid, acetaminophen, dopamine, or mannitol during follow-up. Capillary and serum blood glucose samples were collected simultaneously by finger-stick and venipuncture 2 hours after lunch, by the same observer, who was blinded to the serum glucose results. First, between July and November 2009, capillary glucose levels were measured using the blood glucose meters OneTouch SureStep® and MediSense Optium®. Between November 2009 and February 2010, capillary blood glucose levels were measured on the glucose meters OneTouch SureStep and Optium Xceed®. The capillary glucose readings were analyzed between meters and also in relation to the serum blood glucose values by the t-test for paired samples and the Mood two-sample test.Results: The patients’ mean age was 50.45 years. The blood glucose means obtained using the meters OneTouch SureStep, MediSense Optium, and Optium Xceed were, respectively, 183.87 mg/dL, 178.49 mg/dL, and 192.73 mg/dL, and the mean for the serum glucose values was 174.58 mg/dL. A significant difference was found between the capillary measurements taken by the glucose meters and the serum glucose measurements (P < 0.05, and no

  15. Demonstration of disinfection procedure for the development of accurate blood glucose meters in accordance with ISO 15197:2013

    Science.gov (United States)

    Lin, Wen-Ye; Chang, Jung-Tzu; Chu, Chun-Feng

    2017-01-01

    Despite measures to reduce disease transmission, a risk can occur when blood glucose meters (BGMs) are used on multiple individuals or by caregivers assisting a patient. The laboratory and in-clinic performance of a BGM system before and after disinfection should be demonstrated to guarantee accurate readings and reliable control of blood glucose (BG) for patients. In this study, an effective disinfection procedure, conducting wiping 10 times to assure a one minute contact time of the disinfectant on contaminated surface, was first demonstrated using test samples of the meter housing materials, including acrylonitrile butadiene styrene (ABS), polymethyl methacrylate (PMMA), and polycarbonate (PC), in accordance with ISO 15197:2013. After bench studies comprising 10,000 disinfection cycles, the elemental compositions of the disinfected ABS, PMMA, and PC samples were almost the same as in the original samples, as indicated by electron spectroscopy for chemical analysis. Subsequently, the validated disinfection procedure was then directly applied to disinfect 5 commercial BGM systems composed of ABS, PMMA, or PC to observe the effect of the validated disinfection procedure on meter accuracy. The results of HBsAg values after treatment with HBV sera and disinfectant wipes for each material were less than the LoD of each material of 0.020 IU/mL. Before and after the multiple disinfection cycles, 900 of 900 samples (100%) were within the system accuracy requirements of ISO 15197:2013. All of the systems showed high performance before and after the series of disinfection cycles and met the ISO 15197:2013 requirements. In addition, our results demonstrated multiple cleaning and disinfection cycles that represented normal use over the lifetime of a meter of 3–5 years. Our validated cleaning and disinfection procedure can be directly applied to other registered disinfectants for cleaning commercial BGM products in the future. PMID:28683148

  16. How to measure blood glucose

    Directory of Open Access Journals (Sweden)

    Dianne Pickering

    2014-12-01

    Full Text Available The level of glucose in the blood can be measured by applying a drop of blood to a chemically treated, disposable ‘test-strip’, which is then inserted into an electronic blood glucose meter. The reaction between the test strip and the blood is detected by the meter and displayed in units of mg/dL or mmol/L. There are a number of different types of meters available, and all are slightly different. Take care when applying the general principles described in this article to the specific glucose meter you are using.

  17. Roche Portable Blood Glucose Meter for Clinical Application and Quality Control%便携式血糖仪临床应用与质量控制

    Institute of Scientific and Technical Information of China (English)

    谭丹华

    2014-01-01

    Diabetes is a lifelong disease is stil no cure at present, timing determination of glucose, strict control of blood glucose is the key to the treatment of diabetes melitus. Diabetes ideal blood glucose test is weekly 1~2 times, but generaly patients with no conditions to the hospital for frequent blood glucose testing, and the portable blood glucose meter provides great convenience for patients, the portable blood glucose meter for each ward monitoring blood glucose in patients with circadian changes and outpatient diabetes screening, increasingly the attention of medical workers and patients in this paper, Glucose meter in the clinical diagnosis of practical value in clinical application, quality assessment.%糖尿病是目前尚不能根治的终身性疾病,定时测定血糖值,严格控制血糖是糖尿病治疗的关键。糖尿病理想的血糖测试是每周1~2次,但一般患者没条件到医院作频繁的血糖测试,而便携式血糖仪为患者提供了很大的方便。便携式血糖仪因适合各病房昼夜监测患者血糖变化及门诊患者糖尿病筛查,日益受到医务工作者和患者的重视,本文从临床应用、质量检测评估方面阐述血糖仪在临床诊断的实用价值。

  18. Blood glucose test in the fast blood glucose meter and the value of conventional biochemical instrument analysis%血糖检验中快速血糖仪和常规生化仪的价值分析

    Institute of Scientific and Technical Information of China (English)

    胡政兵; 刘宁

    2015-01-01

    目的::探讨快速血糖仪和常规生化仪在临床血糖检验中应用的价值差异。方法:某院收治的82例患者为研究对象,对所有患者均采用快速血糖仪和常规生化仪检验血糖,对比两种方法的应用价值的差异。结果:快速血糖仪单次检测的血糖值为(6.20±1.18)mmol/L,多次检测的血糖值为(5.53±1.03)mmol/L,常规生化仪单次检测的血糖值为(5.69±1.12)mmol/L,多次检测的血糖值为(5.81±0.96)mmol/L。经统计学分析,两种方法比较差异无统计学意义(P>0.05)。结论:快速血糖仪具有常规生化仪在检验血糖方面的准确性,而且使用更简易可行和经济实用,能一定程度上减轻患者的身心负担和经济压力,利于医生及时确诊和给予救治措施,具有一定的临床推广和应用价值。%Objective:To study the fast blood glucose meter and conventional biochemical instrument in clinical application value of differences in blood sugar test. Methods: 82 cases of patients as the research object, adopt the fast blood glucose meter for all patients and normal biochemical analyzer test blood sugar, compared the difference of the value of the application of the two methods. Results:blood sugar value of fast blood glucose meter single detection (6.20±1.18)mmol/L, repeatedly testing blood glucose value is (5.53± 1.03) mmol/L;Routine biochemistry analyzer the blood sugar value of single detection (5.69 ± 1.12) mmol/L, multiple testing blood glucose value is (5.81 ± 0.96) mmol/L.After statistical analysis, P>0.05 there was no statistically significant difference comparing the two methods. Conclusion:fast blood glucose meter with conventional biochemical analyzer in the accuracy of the test blood glucose, and more simple and feasible and economical and practical to use, and to a certain extent, reduce the patient's physical and mental burden and economic pressures, conducive to the doctor in time

  19. Low Blood Glucose (Hypoglycemia)

    Science.gov (United States)

    ... Disease, & Other Dental Problems Diabetes & Sexual & Urologic Problems Low Blood Glucose (Hypoglycemia) What is hypoglycemia? Hypoglycemia, also called low blood glucose or low blood sugar, occurs when ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High blood glucose happens when the body has too little insulin or when the body can't use insulin properly. What Causes Hyperglycemia? A number of things can cause hyperglycemia: ...

  3. 全自动生化仪与快速血糖仪测定血糖浓度的比较%Comparison between automatic biochemical analyzer and rapid blood sugar meter for determining glucose blood concen-tration

    Institute of Scientific and Technical Information of China (English)

    刘兴高; 成平

    2015-01-01

    目的:探讨全自动生化仪测定静脉促凝血清标本血糖浓度与快速血糖仪测定静脉抗凝全血标本血糖浓度的相关性及差异。方法采集该院200名住院患者的血液标本,同一患者同时采集静脉促凝血清标本与静脉抗凝全血标本,采用全自动生化仪测定静脉促凝血清标本血糖浓度,同时采用快速血糖仪测定静脉抗凝全血标本血糖浓度,比较2组血糖浓度测定结果。结果191名患者的静脉促凝血清标本血糖浓度明显大于其静脉抗凝全血标本血糖浓度,差异范围在0.50~1.50 mmol/L ,差异有统计学意义(P<0.05)。结论全自动生化仪测定静脉促凝血清标本血糖浓度明显高于快速血糖仪测定静脉抗凝全血标本的血糖浓度。%Objective To investigate the correlation and difference between the automatic biochemical analyzer for determining the blood glucose concentration in the venous coagulant serum specimens and the fast blood glucose meter for determining the blood glucose concentration in the venous coagulant whole blood specimens .Methods The blood specimens of 200 inpatients in the Geleshan Branch Hospital were collected ,venous coagulant serum specimens and the venous coagulant whole blood specimens in the same patient were simultaneously collected .The automatic bi‐ochemical analyzer was adopted to detect the blood glucose concentration of venous coagulant serum specimens ,and at the same time the rapid blood glucose meter was adopted to detect the blood glucose concentration of venous coagu‐lant whole blood specimens .The blood glucose detection results were compared between the two detection methods . Results In 191 patients ,the blood glucose concentration of venous coagulant serum specimens was significantly grea‐ter than that of the venous coagulant whole blood specimens ,the difference range was 0 .50 -1 .50 mmol/L ,the difference was statistically significant (P<0 .05

  4. The danger of using inappropriate point-of-care glucose meters in patients on icodextrin dialysis.

    Science.gov (United States)

    Perera, N J; Stewart, P M; Williams, P F; Chua, E L; Yue, D K; Twigg, S M

    2011-10-01

    Icodextrin is a glucose polymer used to maintain an osmotic gradient in peritoneal dialysis. Metabolites of icodextrin are known to cause overestimation of blood glucose in glucose meters using glucose dehydrogenase/pyrroloquinolinequinone systems. The aim of this study is to determine the extent of icodextrin interference in glucose meters using the newer glucose dehydrogenase/NAD or glucose oxidase systems. This has not been established previously. Fasting blood samples (n = 4) were spiked with either one icodextrin metabolite (maltose, maltotriose or maltotetraose) or a combination, at various blood concentrations expected during dialysis. Samples were tested in triplicate on: five glucose-meters, a Radiometer® (glucose oxidase/hydrogen peroxide) and laboratory (hexokinase) analysers. Each meter was also tested on blood from six patients undergoing dialysis. Accuracy was evaluated as % Bias = [(meter glucose - laboratory glucose)/laboratory glucose] × 100. A single icodextrin metabolite affected glucose measurements and, in combination, the interferences were additive in the two Accu-Chek® and Optium® Xceed meters by > 10%. Amongst these meters, the Optium Xceed 5-s machine was less affected. Meters using glucose oxidase were least affected by interference. A similar trend in interference was observed in vivo. While meters using glucose dehydrogenase/NAD are less affected by icodextrin metabolites, interference can still be demonstrated. The degree of interference can vary in different glucose meters using this enzyme/cofactor system, as seen in the Optium Xceed machines. Icodextrin is an important source of interference that sometimes even experienced professionals are unaware of and which leads to clinically significant errors in insulin dose adjustment. Awareness of this interference and selection of the most appropriate glucose meters are crucial to minimize this hazard. © 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

  5. Performance evaluation of 20 blood glucose meters for home use testing%20台家庭检验血糖仪性能评价

    Institute of Scientific and Technical Information of China (English)

    汪俊汉; 黄刚; 卢蓉; 江虹; 冯敏; 姚伟; 陈艳铭; 胡红云

    2015-01-01

    目的:评价社区家庭检验血糖仪的精密度和准确度。方法应用 ISO15197:2013版“体外诊断检验系统‐自测用血糖监测系统的要求”标准,使用毛细血管血和静脉血,分别用于血糖仪和实验室生化分析仪测定血液葡萄糖浓度,对每台血糖仪与生化分析仪的检测结果进行偏差分析。结果在被评价的20台血糖仪中,全部不能满足 ISO15197:2013版要求(血糖浓度小于5.5 mmol/L 时,≥95%的检测结果偏差在±0.83 mmol/L 范围内;血糖浓度大于或等于 5.5 mmol/L 时,偏差在±15%范围内),只有11台(55%)进口血糖仪达到国家标准。结论20台血糖仪的偏差范围为-28.7%~3.8%,平均偏差为-12.2%,这样的检测结果将给糖尿病患者的治疗带来极大的风险。定期的、规范的血糖仪性能评价能够确保糖尿病患者自我监测血糖的质量。%Objective To evaluate the precision and accuracy of blood glucose meter(BGM ) for community home use testing . Methods According to the In Vitro Diagnostic Test Systems‐Requirements for Blood Glucose Monitoring Systems for Self‐Testing in Managing Diabetes Mellitus in DIN EN ISO15197 :2013 .Capillary blood and venous blood were tested by BGM and the laborato‐ry biochemical analyzer respectively .The measurement results of each BGM were compared with the results of the biochemical ana‐lyzer for conducting the bias analysis .Results In evaluated 20 BGM ,none of them met the requirements of ISO15197 :2013(when blood glucose concentrations < 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 0 .83 mmol/L ;when blood glucose concentrations ≥ 5 .5 mmol/L ,the bias in 95% of detection results is within the range of ± 15% .Only 11 imported BGM (55% ) met the state standard .Conclusion The bias of 20 BGM ranged - 28 .7% - 3 .8% ,with the average bias of - 12 .2% . These detection results will bring

  6. Comparison of blood glucose test results between point-of-care testing glucose meter and biochemical analyzer%POCT血糖仪与生化分析仪血糖检测结果的比对试验及分析

    Institute of Scientific and Technical Information of China (English)

    刘加红

    2014-01-01

    Objective To explore precision and accuracy of point-of-care testing(POCT) blood glucose meter through comparing blood glucose results between POCT glucose meter and biochemical analyzer. Methods Selected 4 sets of POCT glucose meter to detect the same sample and compared blood glucose results between Beckman CX-9 biochemical analyzer and POCT blood glucose meter. Results Measured results of Beckman CX-9 biochemical analyzer and POCT glucose meter were highly correlated(P>0.05), differences were not statistically significant. Conclusion POCT blood glucose meter is a consistent and convenient detection method for measuring blood glucose results as biochemical analyzer, so it is worthy of clinical promotion and application.%目的对比床旁检测(POCT)血糖仪与生化分析仪对血糖测定的结果,对POCT血糖仪的精密度与准确度进行探讨。方法选用4台POCT血糖仪对同一标本进行测定,并比较贝克曼CX-9生化分析仪与POCT血糖仪的测定结果。结果贝克曼CX-9生化分析仪与POCT血糖仪的测定结果高度相关(P>0.05),差异不具有统计学意义。结论 POCT血糖仪与生化分析仪对血糖的测定结果具有一致性,且方便快捷,可作为急诊的检测方法,值得在临床过程中推广、应用。

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Islanders American Indian/Alaska Native Programs Older Adults Family Link Diabetes EXPO Upcoming Diabetes EXPOs EXPO Volunteer ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... an Employer Options for the Uninsured Medicare Medicaid & CHIP For Parents & Kids Safe at School Everyday Life ... blood sugar). High blood glucose happens when the body has too little insulin or when the body ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Options for the Uninsured Medicare Medicaid & CHIP For Parents & Kids Safe at School Everyday Life Children and ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Clinical Practice Guidelines Patient Education Materials Scientific Sessions Journals for Professionals Professional Books Patient Access to Research ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... events, such as eating breakfast, take on exaggerated importance. It's a world where a person needs a ... Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood Glucose A1C and eAG Hypoglycemia ( ...

  16. A tale of two compartments: interstitial versus blood glucose monitoring.

    Science.gov (United States)

    Cengiz, Eda; Tamborlane, William V

    2009-06-01

    Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, while raising questions about the relationships between interstitial and blood glucose levels. This article will review the differences between interstitial and blood glucose and some of the challenges in measuring interstitial glucose levels accurately.

  17. 301悦优血糖仪的性能评估:一项多中心临床试验%Performance of Yueyou 301 blood glucose monitoring meter in a multicenter clinic study

    Institute of Scientific and Technical Information of China (English)

    王海滨; 陈康; 赵家军; 冉兴无; 朱大龙; 刘超; 巴建明; 母义明

    2014-01-01

    Objective This multicenter clinic study was conducted to evaluate the accuracy of Yueyou 301 blood glucose meter (Yuwell Medical Equipment & Supply Co.,Ltd.,Jiangsu,China) in comparison with YSI2300 Stat Plus glucose analyzer.Methods Capillary blood glucose and the forearm venous plasma glucose levels were measured with the Yueyou 301 glucose meter and YSI 2300 Stat Plus glucose analyzer.In accordance with the ISO 15197:2003 requirements and permits,Yuwell laboratory obtained the extremely low and high concentration samples,which were also assessed by the glucose meter and the glucose analyzer.Taking the venous plasma glucose as the reference value,the accuracy of the Yuwell glucose meter was evaluated flowing the DIN EN ISO (International Organization for Standardization) 15197:2003.The consistency of capillary blood glucose and venous plasma glucose was studied by Consensus Error Grid Analysis,the correlation of capillary blood glucose and venous plasma glucose was analyzed according to liner regression analysis.Reproducibility precision test was carried on in the Yuwell laboratory with the control solution of high and low concentration tested for 20 times in five glucose meters.Results There were 1 092 venous plasma glucose values paired with capillary blood glucose values,of which,comparing to venous plasma glucose,98.6% met the minimum requirements defined by the ISO15197:2003 standard (95% of all measurements within ± 0.83 mmol/L for the range < 4.2 mmol/L and ± 20% for the glucose range ≥ 4.2mmol/L).Paired glucose measurements from the Yueyou 301 glucose meter and laboratory glucose measurement demonstrated that 100% of paired points in the overall subject population fell in zones A and B of the error grid analyze.The capillary blood glucose value was well correlated to venous plasma glucose value in the overall level(r=0.981 5).Regarding the reproducibility,the low concentrations (< 5.6 mmol/L) had SD ≤ 1.51 mg/dl (< 0.1mmol/L),which was

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... how to handle this condition. Medical IDs Many people with diabetes, particularly those who use insulin, should ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... Type 2 Diabetes Program Food & Fitness Food Recipes Planning Meals What Can I Eat Weight Loss Fitness ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... also help. Work with your dietitian to make changes in your meal plan. If exercise and changes ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... Sleeve Custom jerseys for your Tour de Cure team benefits the cause. Ask the Experts: Learn to ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin ... Diabetes Pro: Professional Resources Online We Support Your Doctor Clinical Practice Guidelines Patient Education Materials Scientific Sessions ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C ... your doctor may change the amount of your medication or insulin or possibly the timing of when ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose early will help you avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? You ... Advocacy Take Action Advocacy Priorities News & Events The Cost of Diabetes Advocate Toolkit Call to Congress Research & ...

  8. Valores glicêmicos oferecidos pelo glicosímetro portátil, utilizando sangue de diferentes vias de coleta: estudo de validade Portable blood glucose meter values using different sampling ways: a validity study

    Directory of Open Access Journals (Sweden)

    Ana Paula Bello Argollo

    2010-12-01

    Full Text Available OBJETIVO: Identificar se há diferença significativa entre os resultados glicêmicos oferecidos pelo glicosímetro portátil, utilizando sangue obtido de diferentes vias de coleta e pela análise laboratorial. MÉTODOS: Estudo quantitativo de validade. Foram coletadas diariamente amostras de sangue capilar, do cateter venoso central e do catéter arterial para verificação da glicemia pelo glicosímetro, e feita análise da glicemia laboratorial. Para análise, foi utilizado o programa Statistical Package for the Social Sciences - SPSS. RESULTADOS: Observou-se que glicemia processada no glicosímetro portátil, com amostra de sangue do cateter venoso central, foi a que apresentou maior correlação com o valor oriundo do laboratório, considerando-se este o "padrão-ouro". CONCLUSÃO: Coletas por via capilar, em pacientes graves e instáveis hemodinamicamente, podem trazer resultados glicêmicos falsos, levando a alterações indevidas da solução de insulina É preciso atentar para a via de coleta ideal da glicemia em pacientes graves, afim de que não haja erro no manuseio da solução de insulina.OBJECTIVE: To identify the relevant differences between portable blood glucose meter readings in different sampling accesses blood and laboratory analysis. METHODS: Quantitative validity study. Daily samples were collected from capillary blood, central venous access catheter and arterial catheter and the blood glucose values checked using portable blood glucose meter and laboratory analysis. The findings were analyzed with the Statistical Package for the Social Sciences - SPSS software. RESULTS: Central venous catheter samples blood glucose meter readings were found to have the best correlation with the laboratory analysis results, considered as the gold-standard. CONCLUSION: Hemodynamically unstable patients' capillary blood samples may provide false blood glucose results, and lead to inappropriate insulin solution management. Therefore, ideal

  9. Blood Glucose Levels

    Directory of Open Access Journals (Sweden)

    Carlos Estela

    2011-01-01

    Full Text Available The purpose of this study was to establish a mathematical model which can be used to estimate glucose levels in the blood over time. The equations governing this process were manipulated with the use of techniques such as separation of variables and integration of first order differential equations, which resulted in a function that described the glucose concentration in terms of time. This function was then plotted, which allowed us to find when glucose concentration was at its highest. The model was then used to analyze two cases where the maximum glucose level could not exceed a certain level while the amount of carbohydrates and glycemic index were varied, independently.

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll in ...

  11. Analysis of the Value of Rapid Blood Glucose Meter and Routine Biochemical Analyzer in Clinical Blood Glucose Test%临床血糖检验中快速血糖仪与常规生化仪应用的价值分析

    Institute of Scientific and Technical Information of China (English)

    尹保杰

    2015-01-01

    目的:探究临床血糖检验中快速血糖仪与常规生化仪的临床应用效果。方法选取2013年4月~2014年4月于我院就诊并且接受血糖检验的68例患者,采用回顾性分析法对所有患者的临床资料进行分析,并同时给予68例患者快速血糖仪与常规生化仪检验,对比两种检验方法的检验效果。结果快速血糖仪的血糖测量值为(5.81±0.02) mmol/L,常规生化仪的血糖测量值为(5.64±0.03)mmol/L,差异不具有统计学意义(P>0.05)。结论快速血糖仪具有高效、快捷、经济等特点,有利于诊断和治疗。%Objective Explore the clinical effect of rapid clinical blood test blood glucose meter and conventional biochemical analyzer.Methods 68 cases of patients receiving blood sugar test were chosen from April 2013 to April 2014 in our hospital, the use of a retrospective analysis of clinical data for all patients were analyzed, and 68 patients while giving fast meter with conventional biochemical analyzer test, test the effect of comparison of the two test methods.Results The test result of blood glucose is (5.81±0.02) mmol/L when using rapid blood glucose meter and the test result of blood glucose is (5.64±0.03) mmol/L when using conventional biochemical analyzer. The difference of results between two methods is not statistically significant (P>0.05).Conclusion The rapid blood glucose meter is an efifcient, fast, economic test method. It helps to diagnosis and treatment.

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... work with your doctor to find the safest way for you to lower your blood glucose level. Cutting down on the amount of food you eat might also help. Work with your dietitian to make changes in your meal plan. If exercise and changes ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health Insurance Health Insurance ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia ( ... Advocacy Take Action Advocacy Priorities News & Events The Cost of Diabetes Advocate ... Resources Shop Diabetes » Close nonprofit software

  16. Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose.

    Science.gov (United States)

    Boyd, J C; Bruns, D E

    2001-02-01

    Proposed quality specifications for glucose meters allow results to be in error by 5-10% or more of the "true" concentration. Because meters are used as aids in the adjustment of insulin doses, we aimed to characterize the quantitative effect of meter error on the ability to identify the insulin dose appropriate for the true glucose concentration. Using Monte Carlo simulation, we generated random "true" glucose values within defined intervals. These values were converted to "measured" glucose values using mathematical models of glucose meters having defined imprecision (CV) and bias. For each combination of bias and imprecision, 10,000-20,000 true and measured glucose concentrations were matched with the corresponding insulin doses specified by selected insulin-dosing regimens. Discrepancies in prescribed doses were counted and their frequencies plotted in relation to bias and imprecision. For meters with a total analytical error of 5%, dosage errors occurred in approximately 8-23% of insulin doses. At 10% total error, 16-45% of doses were in error. Large errors of insulin dose (two-step or greater) occurred >5% of the time when the CV and/or bias exceeded 10-15%. Total dosage error rates were affected only slightly by choices of sliding scale among insulin dosage rules or by the range of blood glucose. To provide the intended insulin dosage 95% of the time required that both the bias and the CV of the glucose meter be <1% or <2%, depending on mean glucose concentrations and the rules for insulin dosing. Glucose meters that meet current quality specifications allow a large fraction of administered insulin doses to differ from the intended doses. The effects of such dosage errors on blood glucose and on patient outcomes require study.

  17. 适合低功耗便携式血糖仪的SoC芯片与方案实现%The Implementation of Low Power SoC Chip and Solution for Portable Blood Glucose Meter

    Institute of Scientific and Technical Information of China (English)

    陈宏铭; 李水竹; 陈宏维; 程玉华

    2012-01-01

    本文介绍了适合便携式血糖仪的低功耗SoC芯片结构和性能,完成模拟数据采集和信号处理功能。本文还阐述了SoC芯片在血糖仪中的软硬件设计,并进一步说明了SoC设计在实际应用中的几个重要功能,例如低功耗睡眠模式,低噪声运放与温度传感器等。血糖和酶电极反应时所产生的微弱电流经过放大、滤波、模数变换后经SoC芯片数据处理,在液晶显示器上显示出测试结果。本文所提出的SoC设计整合低噪声运算放大器转换微弱的血糖信号成电压信号,测试范围达1.1-33.3mmol/L,单次采血量仅为3μL,完成一次测试的时间约4秒,片外的EEPROM可以存储256组历史记录,还具有自动温度补偿与校正功能,适合个人、家庭或医院使用。%In this paper, the architecture and features of the proposed low power SoC which is suitable for portable blood glucose meter are introduced,analog data acquisition and signal processing were completed by the SoC. Hardware and software design for the blood glucose meter on SoC are described. Several functions in SoC, such as low power consumption in sleep mode, low noise amplifier and temperature sensor are explained in detail for real application. The weak electrical current is detected by the blood glucose meter of immobilizing enzyme on pole. After amplification and filtering, A/D conversion and then data processing by SoC, the measured result is displayed on LCD. The weak blood glucose signal is converted into a voltage signal by the low noise OPAMP in the SoC design. The measurement range of the glucose meter is from 1.1 mmol/L to 33.3 mmol/L, a blood sample as small as 3 μ L and 4 see. test time. The external EEPROM is used to store historical data. Automatic temperature compensation and calibration can be done in this meter. It is suitable for personal health, housing service and hospital care.

  18. Variable classifications of glycemic index determined by glucose meters.

    Science.gov (United States)

    Lin, Meng-Hsueh Amanda; Wu, Ming-Chang; Lin, Jenshinn

    2010-07-01

    THE STUDY EVALUATED AND COMPARED THE DIFFERENCES OF GLUCOSE RESPONSES, INCREMENTAL AREA UNDER CURVE (IAUC), GLYCEMIC INDEX (GI) AND THE CLASSIFICATION OF GI VALUES BETWEEN MEASURED BY BIOCHEMICAL ANALYZER (FUJI AUTOMATIC BIOCHEMISTRY ANALYZER (FAA)) AND THREE GLUCOSE METERS: Accue Chek Advantage (AGM), BREEZE 2 (BGM), and Optimum Xceed (OGM). Ten healthy subjects were recruited for the study. The results showed OGM yield highest postprandial glucose responses of 119.6 +/- 1.5, followed by FAA, 118.4 +/- 1.2, BGM, 117.4 +/- 1.4 and AGM, 112.6 +/- 1.3 mg/dl respectively. FAA reached highest mean IAUC of 4156 +/- 208 mg x min/dl, followed by OGM (3835 +/- 270 mg x min/dl), BGM (3730 +/- 241 mg x min/dl) and AGM (3394 +/- 253 mg x min/dl). Among four methods, OGM produced highest mean GI value than FAA (87 +/- 5) than FAA, followed by BGM and AGM (77 +/- 1, 68 +/- 4 and 63 +/- 5, pOGM are more variable methods to determine IAUC, GI and rank GI value of food than FAA. The present result does not necessarily apply to other glucose meters. The performance of glucose meter to determine GI value of food should be evaluated and calibrated before use.

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Us in the Fight for a Cure Your tax-deductible gift today can fund critical diabetes research ... glucose for fuel, so your body breaks down fats to use for energy. When your body breaks ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers ... updated, this is the "take-you-by-the-hand" guide that will become a trusted friend and ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health Insurance Health ... glucose happens when the body has too little insulin or when the body can't use insulin ...

  2. Bedside Blood Glucose Monitoring in Hospitals

    National Research Council Canada - National Science Library

    American Diabetes Association

    2004-01-01

    Bedside Blood Glucose Monitoring in Hospitals American Diabetes Association The modern management of hospitalized patients with diabetes includes capillary blood glucose determinations at the bedside...

  3. Intraoperative accuracy of a point-of-care glucose meter compared with simultaneous central laboratory measurements.

    Science.gov (United States)

    Mraovic, Boris; Schwenk, Eric S; Epstein, Richard H

    2012-05-01

    Concerns have been raised about the use of point-of-care (POC) glucose meters in the hospital setting. Accuracy has been questioned especially in critically ill patients. Although commonly used in intensive care units and operating rooms, POC meters were not approved by the Food and Drug Administration for such use. Data on POC glucose meter performance during anesthesia are lacking. We evaluated accuracy of a POC meter in the intraoperative setting. We retrospectively reviewed 4,333 intraoperative records in which at least one intraoperative glucose was measured using electronic medical records at a large academic hospital. We evaluated the accuracy of a POC glucose meter (ACCU-CHEK® Inform, Roche Pharmaceuticals) based on the 176 simultaneous central laboratory (CL) blood glucose (BG) measurements that were found (i.e., documented collection times within 5 minutes). Point-of-care and central lab BG differences were analyzed by Bland-Altman and revised error grid analysis (rEGA). Mean POC BG was 163.4 ± 64.7 mg/dl [minimum (min) 48 mg/dl, maximum (max) 537 mg/dl] and mean CL BG was 162.6 ± 65.1 mg/dl (min 44 mg/dl, max 502 mg/dl). Mean absolute difference between POC and CL BG was 24.3 mg/dl. Mean absolute relative difference was 16.5% with standard deviation 26.4%. Point-of-care measurements showed a bias of 0.8 relative to the corresponding CL value, with a precision of 39.0 mg/dl. Forty (23%) POC BG values fell outside the Clinical and Laboratory Standards Institute guideline and 3.4% POC measurements fell in zones C and D of the rEGA plot. The tested POC glucose meter performed poorly compared to a CL analyzer intraoperatively. Perioperative clinicians should be aware of limitations of specific POC glucose meters, and routine use of POC glucose meters as sole measurement devices in the intraoperative period should be carefully considered. © 2012 Diabetes Technology Society.

  4. Blood glucose in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj

    2009-01-01

    Blood glucose is often elevated in acute stroke, and higher admission glucose levels are associated with larger lesions, greater mortality and poorer functional outcome. In patients treated with thrombolysis, hyperglycemia is associated with an increased risk of hemorrhagic transformation...... of infarcts. For a number of years, tight glycemic control has been regarded as beneficial in critically illness, but recent research has been unable to support this notion. The only completed randomized study on glucose-lowering therapy in stroke has failed to demonstrate effect, and concerns relating...... to the risk of inducing potentially harmful hypoglycemia has been raised. Still, basic and observational research is overwhelmingly in support of a causal relationship between blood glucose and stroke outcome and further research on glucose-lowering therapy in acute stroke is highly warranted....

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- Support a Cure - 2017-05-donation- ... well with diabetes. Shopdiabetes.org: Your Stress-Free System for Family Dinners! - 2017-03-book-oclock-scramble. ...

  6. Capillary blood glucose screening for gestational diabetes: a preliminary investigation.

    Science.gov (United States)

    Landon, M B; Cembrowski, G S; Gabbe, S G

    1986-10-01

    Home glucose monitoring with the use of reflectance meters is an important adjunct in the care of pregnant women with insulin-dependent diabetes. The accuracy of reflectance meters for the assay of capillary glucose specimens has been well documented. The present preliminary study was undertaken to determine the utility of outpatient screening for gestational diabetes mellitus with the use of a reflectance meter (Accu-Chek, Boehringer Mannheim Co.). One hundred twenty-five patients in our high-risk practice had a standard 50 gm glucose load at 26 to 28 weeks' gestation. Capillary glucose values were measured on site with the Accu-Chek. Venous plasma glucose levels were measured by the central laboratory chemistry analyzer. While the laboratory (x) and meter (y) glucose determinations between the two sets of values were highly correlated (R = 0.89, p less than 0.001), there was a significant difference in their average values (x = 111.74, y = 136.35, p less than 0.0001). With the use of a receiver operator characteristic curve, a meter value of 160 mg/dl was determined as the optimal threshold for performing a 3-hour glucose tolerance test. The sensitivity and specificity with the use of a meter value of 160 mg/dl were 93% and 96%, respectively, for detecting an abnormal screening test in venous plasma (greater than or equal to 135 mg/dl). A total of 32 glucose tolerance tests were performed, with four patients included who had venous values less than 135 mg/dl. All eight patients with gestational diabetes mellitus were correctly identified. These data suggest that a glucose reflectance meter can be used for accurate outpatient screening of gestational diabetes mellitus. The potential advantages of capillary blood glucose screening include both cost and efficiency. Patients with abnormal screening values can be promptly identified and scheduled for a follow-up 3-hour glucose tolerance test.

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... What Can I Drink? Fruit Dairy Food Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... How Grant Money is Divided Funding the Next Generation of Brilliant Researchers Our Research Foundation Diabetes Pro: ... they build up in your blood, which can lead to ketoacidosis. Ketoacidosis is life-threatening and needs ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes ... Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  11. In vivo blood glucose quantification using Raman spectroscopy.

    Directory of Open Access Journals (Sweden)

    Jingwei Shao

    Full Text Available We here propose a novel Raman spectroscopy method that permits the noninvasive measurement of blood glucose concentration. To reduce the effects of the strong background signals produced by surrounding tissue and to obtain the fingerprint Raman lines formed by blood analytes, a laser was focused on the blood in vessels in the skin. The Raman spectra were collected transcutaneously. Characteristic peaks of glucose (1125 cm(-1 and hemoglobin (1549 cm(-1 were observed. Hemoglobin concentration served as an internal standard, and the ratio of the peaks that appeared at 1125 cm(-1 and 1549 cm(-1 peaks was used to calculate the concentration of blood glucose. We studied three mouse subjects whose blood glucose levels became elevated over a period of 2 hours using a glucose test assay. During the test, 25 Raman spectra were collected transcutaneously and glucose reference values were provided by a blood glucose meter. Results clearly showed the relationship between Raman intensity and concentration. The release curves were approximately linear with a correlation coefficient of 0.91. This noninvasive methodology may be useful for the study of blood glucose in vivo.

  12. Interference Reduction in Glucose Detection by Redox Potential Tuning: New Glucose Meter Development.

    Science.gov (United States)

    Cho, Seong Je; Cho, Chul-Ho; Kim, Kwang Bok; Lee, Min-Hyoung; Kim, Jae Hong; Lee, Suho; Cho, Jaegeol; Jung, Suntae; Kim, Dong-Min; Shim, Yoon-Bo

    2015-01-01

    A new glucose meter was developed employing a novel disposable glucose sensor strip comprising a nicotinamide adenine dinucleotide-glucose dehydrogenase (NAD-GDH) and a mixture of Fe compounds as a mediator. An iron complex, 5-(2,5-di(thiophen-2-yl)-1H-pyrrol-1-yl)-1,10-phenanthroline iron(III) chloride (Fe-PhenTPy), was synthesized as a new mediator for the NAD-GDH system. Due to the high oxidation potential of the mediator, the detection potential was tuned to be more closely fitted toward the enzyme reaction potential, less than 400 mV (vs. Ag/AgCl), by mixing with an additional iron mediator. The impedance spectrometry for the enzyme sensor containing the mixed mediators showed an enhanced charge transfer property. In addition, a new cartridge-type glucose meter was manufactured using effective aligned-electrodes, which showed an enhanced response compared with conventional electrode alignment. The proposed glucose sensor resulted in a wide dynamic range in the concentration range of 30 - 500 mg dL(-1) with a reduced interference effect and a good sensitivity of 0.57 μA mM(-1).

  13. Why control blood glucose levels?

    Science.gov (United States)

    Rossini, A A

    1976-03-01

    The controversy as to the relationship between the degree of control of diabetes and the progression of the complications of the disease has not been solved. However, in this review, various studies suggesting a relationship between the metabolic abnormality and the diabetic complications are examined. The disadvantages of the uncontrolled diabetes mellitus can be divided into two major categories-short-term and long-term. The short-term disadvantages of controlled diabetes mellitus include the following: (1) ketoacidosis and hyperosmolar coma; (2) intracellular dehydration; (3) electrolyte imbalance; (4) decreased phagocytosis; (5) immunologic and lymphocyte activity; (6) impairment of wound healing; and (7) abnormality of lipids. The long-term disadvantages of uncontrolled diabetes melitus include the following: (1) nephropathy; (2) neuropathy; (3) retinopathy; (4) cataract formation; (5) effect on perinatal mortality; (6) complications of vascular disease; and (7) the evaluation of various clinical studies suggesting the relationship of elevated blood glucose levels and complications of diabetes mellitus. It is suggested that until the question of control can absolutely be resolved, the recommendation is that the blood glucose levels should be controlled as close to the normal as possible.

  14. Characterizing Accuracy and Precision of Glucose Sensors and Meters

    National Research Council Canada - National Science Library

    Rodbard, David

    2014-01-01

    Background: There is need for a method to describe precision and accuracy of glucose measurement as a smooth continuous function of glucose level rather than as a step function for a few discrete ranges of glucose...

  15. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...

  16. Biosensing of DNA oxidative damage: a model of using glucose meter for non-glucose biomarker detection

    Science.gov (United States)

    Zhu, Xuena; Sarwar, Mehenur; Yue, Qiaoli; Chen, Chunying; Li, Chen-Zhong

    2017-01-01

    Non-glucose biomarker-DNA oxidative damage biomarker 8-hydroxy-2′-deoxyguanosine (8-OHdG) has been successfully detected using a smartphone-enabled glucose meter. Through a series of immune reactions and enzymatic reactions on a solid lateral flow platform, 8-OHdG concentration has been converted to a relative amount of glucose, and therefore can be detected by conventional glucose meter directly. The device was able to detect 8-OHdG concentrations in phosphate buffer saline as low as 1.73 ng mL−1 with a dynamic range of 1–200 ng mL−1. Considering the inherent advantages of the personal glucose meter, the demonstration of this device, therefore, should provide new opportunities for the monitoring of a wide range of biomarkers and various target analytes in connection with different molecular recognition events. PMID:28203077

  17. Clinical Testing of Blood Glucose Meter Rapid Clinical Significance and Ap-plication of Conventional Biochemical Analyzer%刍议临床血糖检验中快速血糖仪与常规生化仪应用的临床意义

    Institute of Scientific and Technical Information of China (English)

    王金英

    2015-01-01

    目的:研究快速血糖仪以及常规生化仪应用于临床血糖检验工作中发挥的效果。方法选择2013年5月-2014年5月该院68例患者,按每组34例分别设置对照组和观察组,对照组选择常规生化仪开展血糖检验工作,观察组通过快速血糖仪对患者血糖进行临床检验,比较两组检验结果。结果对照组患者最终测出的血糖值为(7.73±3.26)mmol/L;观察组患者最终的血糖检验值为(7.26±3.13)mmol/L,两组患者的检测结果差异无统计学意义(P>0.05)。结论针对患者的临床血糖检验工作,采用快速血糖仪以及常规生化仪所检出的结果不存在显著区别,应用效果不存在明显差异,但是快速血糖仪在检验操作上更为快捷和方便,应用优势较突出。%Objective To study the fast blood glucose meter and biochemical analyzer used in clinical routine blood test work, play effect. Methods From May 2013 to May 2014 in our hospital 68 patients, 34 cases in each group were set ac-cording to the control group and observation group and control group selection routine blood chemistry analyzer to carry out inspection work, study group patients by rapid blood glucose meter clinical blood test, the test results were compared. Re-sults The final group of patients measured blood glucose value (7.73 ± 3.26) mmol / L; Observation group were eventually glucose test is ( 7.26±3.13)mmol/ L, the test results of the two groups were not significantly different, not statistically sig-nificance (P>0.05). Conclusion For patients with clinical blood test work, using rapid blood glucose meter and convention-al biochemical analyzer results are detected significant differences do not exist, there is no significant difference in the ef-fect of the application, but a more rapid glucose meter quick and easy on the test operation, the application more prominent advantages.

  18. Glucose meter performance criteria for tight glycemic control estimated by simulation modeling.

    Science.gov (United States)

    Karon, Brad S; Boyd, James C; Klee, George G

    2010-07-01

    Glucose meter analytical performance criteria required for safe and effective management of patients on tight glycemic control (TGC) are not currently defined. We used simulation modeling to relate glucose meter performance characteristics to insulin dosing errors during TGC. We used 29,920 glucose values from patients on TGC at 1 institution to represent the expected distribution of glucose values during TGC, and we used 2 different simulation models to relate glucose meter analytical performance to insulin dosing error using these 29,920 initial glucose values and assuming 10%, 15%, or 20% total allowable error (TEa) criteria. One-category insulin dosing errors were common under all error conditions. Two-category insulin dosing errors occurred more frequently when either 20% or 15% TEa was assumed compared with 10% total error. Dosing errors of 3 or more categories, those most likely to result in hypoglycemia and thus patient harm, occurred infrequently under all error conditions with the exception of 20% TEa. Glucose meter technologies that operate within a 15% total allowable error tolerance are unlikely to produce large (>or=3-category) insulin dosing errors during TGC. Increasing performance to 10% TEa should reduce the frequency of 2-category insulin dosing errors, although additional studies are necessary to determine the clinical impact of such errors during TGC. Current criteria that allow 20% total allowable error in glucose meters may not be optimal for patient management during TGC.

  19. The feasibility study of screening of metabolic syndrome and impaired glucose regulation in overweight and obese children and adolescents using blood glucose meter.%用血糖仪筛查不同年龄段儿童青少年代谢综合征和糖调节异常的可行性

    Institute of Scientific and Technical Information of China (English)

    彭易清; 梁晶晶; 李珍宇; 聂伟明

    2011-01-01

    Objective To evaluate the feasibility of MS and TGR screening in overweight and obese children and adolescents by measuring the FGB and 2hBG using the blood glucose meter and automatic biochemistry analyzer. Methods From May to October 2010, 6096 middle school students aged 7 to 18 in city of Donguan were censured. The fingertip fasting capillary glucose was screened by blood glucose meter. Students who met any abnormal indexes were included in MS group. On the basis of voluntary principle, 557 male students and 541 female students, who conformed to MS, were assigned into overweight group (Ob); while 469 male health students and 446 female health students were assigned into normal control (NC) group. FCBG, FBG, 2hCBG, 2hBG and Fins were measured at the same time. Subgroup analysis was carried out according to different age groups (7 - l0ys, 11 - 14ys and 14 - 18ys). Results 1. Significant impairments were revealed with striating analysis according to different age groups and genders in systolic pressure, diastolic pressure, FCBG, FBG, 2hCBG, 2hBG, CIFG, IFC, CIGT, CT, Fins, IR and IS in Ob group, comparing with those in NC group ( P < 0. 05 ). Although significantly higher detection rate of IFC was revealed in fingertip blood than that in vein blood, lower detection rate of IGT was found. IFC prevalence was higher in male than female by 20 and 12% at the age of 7 - l0ys and 11 - 14ys, respectively, in Ob group. However, no difference was revealed in IFG prevalence between male and female with age of 15 - 18ys in Ob group. 2. No significant difference was revealed in IFG or IGT detection between fingertip blood and venous screenings in male or female groups ( P > 0. 05 ). Conclusion Screening of metabolic syndrome and the impaired glucose regulation situation in overweight and obese in children and adolescents is feasible.%目的 分析用血糖仪筛查不同年龄段儿童青少年代谢综合征(MS)和糖调节异常(IGR)的可行性.方法 根据志

  20. A glucose meter evaluation co-designed with both health professional and consumer input.

    Science.gov (United States)

    Thompson, Harmony; Chan, Huan; Logan, Florence J; Heenan, Helen F; Taylor, Lynne; Murray, Chris; Florkowski, Christopher M; Frampton, Christopher M A; Lunt, Helen

    2013-11-22

    Health consumer's input into assessment of medical device safety is traditionally given either as part of study outcome (trial participants) or during post marketing surveillance. Direct consumer input into the methodological design of device assessment is less common. We discuss the difference in requirements for assessment of a measuring device from the consumer and clinician perspectives, using the example of hand held glucose meters. Around 80,000 New Zealanders with diabetes recently changed their glucose meter system, to enable ongoing access to PHARMAC subsidised meters and strips. Consumers were most interested in a direct comparison of their 'old' meter system (Accu-Chek Performa) with their 'new' meter system (CareSens brand, including the CareSens N POP), rather than comparisons against a laboratory standard. This direct comparison of meter/strip systems showed that the CareSens N POP meter read around 0.6 mmol/L higher than the Performa system. Whilst this difference is unlikely to result in major errors in clinical decision making such as major insulin dosing errors, this information is nevertheless of interest to consumers who switched meters so that they could maintain access to PHARMAC subsidised meters and strips. We recommend that when practical, the consumer perspective be incorporated into study design related to medical device assessment.

  1. Blood glucose response to pea fiber

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    Two new fiber types, pea fiber (PF) and sugar beet fiber (BF), were compared with wheat bran (WB) to investigate the effect on postprandial blood glucose and serum insulin responses in normal subjects. The control meal consisted of 150 g ground beef mixed with 50 g glucose and 20 g lactulose. Only...

  2. blood glucose level in Bufo gutturalis (power)

    African Journals Online (AJOL)

    Department of Human Physiology and Physiological Chemistry, ... the influence of dehydration on the blood glucose level of anurans. .... J. Cell. Compo Physiol. 44: 233 - 246. VAWDA, A. 1978. The loss of sodium across the skin of the.

  3. Recent developments in blood glucose sensors

    National Research Council Canada - National Science Library

    Wang, Hui-Chen; Lee, An-Rong

    2015-01-01

    ... the complications of the condition. This review article deals with current growth areas in the market for blood glucose sensors and possible future alternatives, which are generally considered to be the point sample test...

  4. [Glucose homeostasis in children. I. Regulation of blood glucose].

    Science.gov (United States)

    Otto Buczkowska, E; Szirer, G; Jarosz-Chobot, P

    2001-01-01

    The amount of glucose in the circulation depends on its absorption from the intestine, uptake by and release from the liver and uptake by peripheral tissues. Insulin and glucagon together control the metabolities required by peripheral tissues and both are involved in maintaining glucose homeostasis. Insulin is considered to be an anabolic hormone in that it promotes the synthesis of protein, lipid and glycogen. The key target tissues for insulin are liver, muscles and adipose tissue. Glucagon acts largely to increase catabolic processes. Between meals or during fast, the most tightly regulated process is the release of glucose from the liver. During fasting glucose is produced from glycogen and is formed by enzymes on the gluconeogenic pathway. Fetal metabolism is directed to ensure anabolism with formation of glycogen, fat and protein. Glucogen is stored in the liver and serves as the immediate source of new glucose during first few hours after birth. Glucose is the most important substrate for brain metabolism. Due to the large size of neonatal brain in relation to body weight cerebral glucose consumption is particularly high. Postnatal hormonal changes have a central role in regulating glucose mobilization through glycogenolysis and gluconeogenesis. The initial glucagon surge is the key adaptive change which triggers the switch to glucose production. The control of insulin and glucagon secretion is of fundamental importance during first hours after birth. Children have a decreased tolerance to starvation when compared with adults, they are more prone to develop hypoglycaemia after short fasting. The faster rate in the fall of blood glucose and gluconeogenic substrates and rapid rate of ketogenesis are characteristic features of fasting adaptation in children.

  5. Accuracy of point-of-care blood glucose measurements in critically ill patients in shock.

    Science.gov (United States)

    Garingarao, Carlo Jan Pati-An; Buenaluz-Sedurante, Myrna; Jimeno, Cecilia Alegado

    2014-09-01

    A widely used method in monitoring glycemic status of ICU patients is point-of-care (POC) monitoring devices. A possible limitation to this method is altered peripheral blood flow in patients in shock, which may result in over/underestimations of their true glycemic status. This study aims to determine the accuracy of blood glucose measurements with a POC meter compared to laboratory methods in critically ill patients in shock. POC blood glucose was measured with a glucose-1-dehydrogenase-based reflectometric meter. The reference method was venous plasma glucose measured by a clinical chemistry analyzer (glucose oxidase-based). Outcomes assessed were concordance to ISO 15197:2003 minimum accuracy criteria for glucose meters, bias in glucose measurements obtained by the 2 methods using Bland-Altman analysis, and clinical accuracy through modified error grid analysis. A total of 186 paired glucose measurements were obtained. ISO 2003 accuracy criteria were met in 95.7% and 79.8% of POC glucose values in the normotensive and hypotensive group, respectively. Mean bias for the normotensive group was -12.4 mg/dL, while mean bias in the hypotensive group was -34.9 mg/dL. POC glucose measurements within the target zone for clinical accuracy were 90.2% and 79.8% for the normotensive and hypotensive group, respectively. POC blood glucose measurements were significantly less accurate in the hypotensive subgroup of ICU patients compared to the normotensive group. We recommend a lower threshold in confirming POC blood glucose with a central laboratory method if clinically incompatible. In light of recently updated accuracy standards, we also recommend alternative methods of glucose monitoring for the ICU population as a whole regardless of blood pressure status.

  6. System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Muhammad Khan

    2014-01-01

    Full Text Available Use of blood glucose (BG meters in the self-monitoring of blood glucose (SMBG significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe, several BG meters claim to meet the ISO guidelines yet fail to do so on internal validation. We conducted a study to determine whether the accuracy of the GlucoRx Nexus TD-4280 meter, utilized by our department for its cost-effectiveness, complied with ISO guidelines. 105 patients requiring laboratory blood glucose analysis were randomly selected and reference measurements were determined by the UniCel DxC 800 clinical system. Overall the BG meter failed to adhere to the ≥95% accuracy criterion required by both the 15197:2003 (overall accuracy 92.4% and 15197:2013 protocol (overall accuracy 86.7%. Inaccurate meters have an inherent risk of over- and/or underestimating the true BG concentration, thereby risking patients to incorrect therapeutic interventions. Our study demonstrates the importance of internally validating the accuracy of BG meters to ensure that its accuracy is accepted by standardized guidelines.

  7. Non-Invasive Optical Blood Glucose Measurement

    Directory of Open Access Journals (Sweden)

    Megha C.Pande

    2013-07-01

    Full Text Available The method for noninvasively blood glucose monitoring system is discussed in this paper. Lot of research work has been done in developing the device which is completely noninvasive to avoid the pros & cons because of frequent pricking. In this paper we are trying to analyze the noninvasive blood glucose measurement study in the near infrared region which is the most suitable region for blood glucose measurement. For this purpose we use a technique which is similar to pulseoximetry based on near infrared spectrometry .An infrared light of particular wavelength is passed through fingertip containing an arterial pulse component are derived,thus minimizing influences of basal components such as resting blood volume,skin, muscle and bone.

  8. Accuracy of self-monitored blood glucose in type 2 diabetes.

    Science.gov (United States)

    Kazlauskaite, Rasa; Soni, Sonia; Evans, Arthur T; Graham, Kelly; Fisher, Betty

    2009-06-01

    The prevalence and predictors of inaccurate self-monitored blood glucose (SMBG) diaries in type 2 diabetes are not well defined. This was a cross-sectional study of adults with type 2 diabetes in a diabetes clinic at a large urban public hospital. We collected copies of SMBG diaries and downloaded data from their glucose meters if patients brought them to their clinic appointment. Trained interviewers used standard tests to assess literacy, depression, and cognitive function. The main outcome measure was accuracy of the glucose diary assessed by comparing reported values to meter memory readings and to results of hemoglobin A(1c). Blood glucose self-monitoring was either missing or misleading for 48% (55 of 115) because (1) patients brought neither meter nor the SMBG diary (n = 26) or (2) the diary was inaccurate (n = 29). An inaccurate glucose diary (by comparison with meter readings) was predicted by normotension (odd ratio 5.6, P = 0.02) and one measure of cognitive impairment, slow Digit Symbol Coding (odds ratio 2.2, P = 0.02). A patient's self-assessment of his or her diary's accuracy was unreliable (sensitivity 63%, specificity 56%). SMBG diaries are frequently either not accurate or not brought to clinic visit. Some inaccuracy might be due to cognitive impairment. To achieve maximum benefit from glucose self-monitoring, glucose meter memory analysis is crucial before making therapy adjustments based on SMBG.

  9. The Diabetes Assistant: A Smartphone-Based System for Real-Time Control of Blood Glucose

    OpenAIRE

    Patrick Keith-Hynes; Benton Mize; Antoine Robert; Jérôme Place

    2014-01-01

    Type 1 Diabetes Mellitus (T1DM) is an autoimmune disease in which the insulin-producing beta cells of the pancreas are destroyed and insulin must be injected daily to enable the body to metabolize glucose. Standard therapy for T1DM involves self-monitoring of blood glucose (SMBG) several times daily with a blood glucose meter and injecting insulin via a syringe, pen or insulin pump. An “Artificial Pancreas” (AP) is a closed-loop control system that uses a continuous glucose monitor (CGM), a...

  10. A novel noninvasive blood glucose monitor.

    Science.gov (United States)

    Malchoff, Carl D; Shoukri, Kamal; Landau, Julian I; Buchert, Janusz M

    2002-12-01

    To evaluate the precision and accuracy of a new advanced prototype of a noninvasive blood glucose monitor across a wide range of serum glucose concentrations. An advanced handheld noninvasive glucose monitor prototype was calibrated and tested using patients recruited by the General Research Center of the University of Connecticut Health Center. The monitor, developed by Infratec, uses principles of thermal emission spectroscopy. The noninvasive measurement of tympanic membrane glucose concentration was calibrated to the serum glucose concentration using 432 paired measurements from 20 subjects with insulin-requiring diabetes. This calibration was subsequently tested (results of power analyses) in a blind fashion with 126 paired measurements from six diabetic subjects who require insulin. In vivo measurements demonstrated the reproducibility of the methodology of the noninvasive glucose monitor. Based on the calibration model, predicted glucose concentrations for six subjects were as follows (for 126 data points): SD = 32 mg/dl, mean absolute relative error (%MARE) = 11.6, with a correlation coefficient of r = 0.87. Noninvasive glucose results were also compared with laboratory reference measurements using an error-in-variables method. Clark error grid analysis showed that 100% of the measurements fell within zones A and B (90% in zone A and 10% in zone B). The SD for all noninvasive measured concentrations was 27 mg/dl, %MARE was 8.6, and the correlation coefficient was r = 0.94. This first independent clinical study of an advanced noninvasive blood glucose prototype based on thermal emission in the mid-infrared spectral region has demonstrated glucose measurements with clinically acceptable accuracy but without the necessity of individual daily calibration.

  11. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    discussions which allowed to receive direct feedback from the point of view of different disciplines. This book is based on the contributions of that workshop and is intended to convey an overview of the different aspects involved in the prediction. The individual chapters are based on the presentations given...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic...... on the net effect of meals on the blood glucose concentration. By assuming that all major unexplained glycemic excursions can be vi Preface attributed to oral glucose ingestion, a meal vector is estimated which significantly improves the mathematical model. Results are shown on three patients during...

  12. Random blood glucose testing in dental practice

    DEFF Research Database (Denmark)

    Barasch, Andrei; Safford, Monika M; Qvist, Vibeke

    2012-01-01

    The prevalence of diabetes mellitus (DM) has been increasing. Instances of patients' not having received a diagnosis have been reported widely, as have instances of poor control of DM or prediabetes among patient's who have the disease. These facts indicate that blood glucose screening is needed....

  13. Blood glucose concentration in pediatric outpatient surgery.

    Science.gov (United States)

    Somboonviboon, W; Kijmahatrakul, W

    1996-04-01

    Blood glucose concentration was measured in 84 pediatric patients who were scheduled for outpatient surgery at Chulalongkorn Hospital. They were allocated into 3 groups according to their ages, group 1:less than 1 year of age, group 2:1 to 5 years of age and group 3:over 5 years. The fasting times were approximately 8-12 hours. All patients received standard general anesthesia under mask. No glucose solution was given during operation. Preoperative mean blood glucose were 91.09 +/- 17.34, 89.55 +/- 18.69 and 82.14 +/- 16.14 mg/dl in group 1, 2 and 3 while the postoperative mean glucose values were 129.07 +/- 37.90, 115.62 +/- 29.63 and 111.53 +/- 23.07 mg/dl respectively. The difference between pre- and post-operative values were statistically significant difference (P postoperative glucose values may be due to stress response from surgery and anesthesia. We would suggest that the parents give the fluid to their children according to our instructions in order to prevent dehydration and hypoglycemia especially in small infants.

  14. Remote Health Consultations Supported by a Diabetes Management Web Application With a New Glucose Meter Demonstrates Improved Glycemic Control.

    Science.gov (United States)

    Grady, Mike; Cameron, Hilary; Levy, Brian L; Katz, Laurence B

    2016-05-01

    Cloud-connected diabetes applications enable health care professionals (HCPs) to monitor patient progress and offer the potential for remote consultations. OneTouch Reveal (OTR) is a cloud-based web application that aggregates data from blood glucose (BG) meters or insulin pumps and provides analytics to help patients and HCPs make more informed treatment and lifestyle decisions. This study assessed the experience of patients using OTR and the OneTouch Verio (OTV) BG meter and determined the extent of changes in glycemic control. Subjects with T1DM (23) or T2DM (17) uploaded BG meter results to OTR for 12 weeks. HCPs remotely reviewed progress using OTR and delivered telephone consultations at 4 and 8 weeks based on OTR insights. After 12 weeks, mean HbA1c decreased by 0.4% (P web application in combination with the OTV meter helped subjects with T1DM and T2DM effectively manage their diabetes and was associated with improved BG control over 12 weeks. Real-time visibility to subject data may help HCPs deliver focused and effective remote consultations. © 2015 Diabetes Technology Society.

  15. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for DiabeticSmartphone...... App” by Valeriya Naumova et al. demonstrates how a highly sophisticated glucose prediction model can be ported from a development language running on a PC to a format such that it can be used conveniently by the patients. A unique feature of the algorithm is its independence of any user input other...

  16. Work related stress and blood glucose levels.

    Science.gov (United States)

    Sancini, A; Ricci, S; Tomei, F; Sacco, C; Pacchiarotti, A; Nardone, N; Ricci, P; Suppi, A; De Cesare, D P; Anzelmo, V; Giubilati, R; Pimpinella, B; Rosati, M V; Tomei, G

    2017-01-01

    The aim of the study is to evaluate work-related subjective stress in a group of workers on a major Italian company in the field of healthcare through the administration of a valid "questionnaire-tool indicator" (HSE Indicator Tool), and to analyze any correlation between stress levels taken from questionnaire scores and blood glucose values. We studied a final sample consisting of 241 subjects with different tasks. The HSE questionnaire - made up of 35 items (divided into 7 organizational dimensions) with 5 possible answers - has been distributed to all the subjects in occasion of the health surveillance examinations provided by law. The questionnaire was then analyzed using its specific software to process the results related to the 7 dimensions. These results were compared using the Pearson correlation and multiple linear regression with the blood glucose values obtained from each subject. From the analysis of the data the following areas resulted critical, in other words linked to an intermediate (yellow area) or high (red area) condition of stress: sustain from managers, sustain from colleagues, quality of relationships and professional changes. A significant positive correlation (p <0.05) between the mean values of all critical areas and the concentrations of glucose values have been highlighted with the correlation index of Pearson. Multiple linear regression confirmed these findings, showing that the critical dimensions resulting from the questionnaire were the significant variables that can increase the levels of blood glucose. The preliminary results indicate that perceived work stress can be statistically associated with increased levels of blood glucose.

  17. Blood Glucose Measurement Using Bioimpedance Technique

    OpenAIRE

    2014-01-01

    Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner ...

  18. Blood Gas Analyzer Accuracy of Glucose Measurements.

    Science.gov (United States)

    Liang, Yafen; Wanderer, Jonathan; Nichols, James H; Klonoff, David; Rice, Mark J

    2017-07-01

    To investigate the comparability of glucose levels measured with blood gas analyzers (BGAs) and by central laboratories (CLs). Glucose measurements obtained between June 1, 2007, and March 1, 2016, at the Vanderbilt University Medical Center were reviewed. The agreement between CL and BGA results were assessed using Bland-Altman, consensus error grid (CEG), and surveillance error grid (SEG) analyses. We further analyzed the BGAs' performance against the US Food and Drug Administration (FDA) 2014 draft guidance and 2016 final guidance for blood glucose monitoring and the International Organization for Standardization (ISO) 15197:2013 standard. We analyzed 2671 paired glucose measurements, including 50 pairs of hypoglycemic values (1.9%). Bland-Altman analysis yielded a mean bias of -3.1 mg/dL, with 98.1% of paired values meeting the 95% limits of agreement. In the hypoglycemic range, the mean bias was -0.8 mg/dL, with 100% of paired values meeting the 95% limits of agreement. When using CEG analysis, 99.9% of the paired values fell within the no risk zone. Similar results were found using SEG analysis. For the FDA 2014 draft guidance, our data did not meet the target compliance rate. For the FDA 2016 final guidance, our data partially met the target compliance rate. For the ISO standard, our data met the target compliance rate. In this study, the agreement for glucose measurement between common BGAs and CL instruments met the ISO 2013 standard. However, BGA accuracy did not meet the stricter requirements of the FDA 2014 draft guidance or 2016 final guidance. Fortunately, plotting these results on either the CEG or the SEG revealed no results in either the great or extreme clinical risk zones. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  19. Blood-Brain Glucose Transfer: Repression in Chronic Hyperglycemia

    Science.gov (United States)

    Gjedde, Albert; Crone, Christian

    1981-10-01

    Diabetic patients with increased plasma glucose concentrations may develop cerebral symptoms of hypoglycemia when their plasma glucose is rapidly lowered to normal concentrations. The symptoms may indicate insufficient transport of glucose from blood to brain. In rats with chronic hyperglycemia the maximum glucose transport capacity of the blood-brain barrier decreased from 400 to 290 micromoles per 100 grams per minute. When plasma glucose was lowered to normal values, the glucose transport rate into brain was 20 percent below normal. This suggests that repressive changes of the glucose transport mechanism occur in brain endothelial cells in response to increased plasma glucose.

  20. Cultural diversity as a factor in self-monitoring blood glucose in gestational diabetes.

    Science.gov (United States)

    Langer, O; Langer, N; Piper, J M; Elliott, B; Anyaegbunam, A

    1995-01-01

    The routine use of self-monitoring of capillary blood glucose by pregnant diabetic patients currently provides the basis for both clinical management and ongoing investigation. Strategies must therefore be developed to ensure that these data are reliable and accurately reported by patients and are not influenced by diverse socioeconomic levels or varied geographic locations. To explore this issue, we used glucose reflectance meters with a memory microchip capable of storing up to 440 consecutive blood glucose determinations. Two diverse groups of women from Texas and New York who had gestational diabetes performed self-monitoring of blood glucose from diagnosis until delivery. Both groups recorded their blood glucose results daily in a logbook. The reporting performance of all the participating subjects resulted in an actual compliance rate of 60% to 70% of testings required of the patients. Comparison of African-American, Mexican-American, and white populations revealed no significant differences in patient performance or compliance. Moreover, no differences were found between the groups at different geographic locations (New York, Texas) in patients' willingness and ability to comply with the regimen of self-monitoring blood glucose. These findings suggest that the use of memory reflectance meters, in conjunction with patient education and positive interaction between patient and care provider, will result in high patient compliance regardless of socioeconomic level or ethnic diversity.

  1. Blood Glucose Measurement Using Bioimpedance Technique

    Directory of Open Access Journals (Sweden)

    D. K. Kamat

    2014-01-01

    Full Text Available Bioimpedance measurement is gaining importance in wide field of bioresearch and biomedical systems due to its noninvasive nature. Noninvasive measurement method is very important to decrease infection and physical injuries which result due to invasive measurement. This paper presents basic principle of bioimpedance along with its application for blood glucose analysis and effect of frequency on impedance measurement. Input from bioimpedance sensor is given to amplifier and signal conditioner AD5933. AD5933 is then interfaced with microcontroller LPC1768 using I2C bus for displaying reading on LCD. Results can also be stored in database using UART interface of LPC1768.

  2. Transmutation of Personal Glucose Meters into Portable and Highly Sensitive Microbial Pathogen Detection Platform.

    Science.gov (United States)

    Wang, Zhenzhen; Chen, Zhaowei; Gao, Nan; Ren, Jinsong; Qu, Xiaogang

    2015-10-07

    Herein, for the first time, we presented a simple and general approach by using personal glucose meters (PGM) for portable and ultrasensitive detection of microbial pathogens. Upon addition of pathogenic bacteria, glucoamylase-quaternized magnetic nanoparticles (GA-QMNPS) conjugates were disrupted by the competitive multivalent interactions between bacteria and QMNPS, resulting in the release of GA. After magnetic separation, the free GA could catalyze the hydrolysis of amylose into glucose for quantitative readout by PGM. In such way, PGM was transmuted into a bacterial detection device and extremely low detection limits down to 20 cells mL(-1) was achieved. More importantly, QMNPS could inhibit the growth of the bacteria and destroy its cellular structure, which enabled bacteria detection and inhibition simultaneously. The simplicity, portability, sensitivity and low cost of presented work make it attractive for clinical applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Modelling, verification, and calibration of a photoacoustics based continuous non-invasive blood glucose monitoring system.

    Science.gov (United States)

    Pai, Praful P; Sanki, Pradyut K; Sarangi, Satyabrata; Banerjee, Swapna

    2015-06-01

    This paper examines the use of photoacoustic spectroscopy (PAS) at an excitation wavelength of 905 nm for making continuous non-invasive blood glucose measurements. The theoretical background of the measurement technique is verified through simulation. An apparatus is fabricated for performing photoacoustic measurements in vitro on glucose solutions and in vivo on human subjects. The amplitude of the photoacoustic signals measured from glucose solutions is observed to increase with the solution concentration, while photoacoustic amplitude obtained from in vivo measurements follows the blood glucose concentration of the subjects, indicating a direct proportionality between the two quantities. A linear calibration method is applied separately on measurements obtained from each individual in order to estimate the blood glucose concentration. The estimated glucose values are compared to reference glucose concentrations measured using a standard glucose meter. A plot of 196 measurement pairs taken over 30 normal subjects on a Clarke error grid gives a point distribution of 82.65% and 17.35% over zones A and B of the grid with a mean absolute relative deviation (MARD) of 11.78% and a mean absolute difference (MAD) of 15.27 mg/dl (0.85 mmol/l). The results obtained are better than or comparable to those obtained using photoacoustic spectroscopy based methods or other non-invasive measurement techniques available. The accuracy levels obtained are also comparable to commercially available continuous glucose monitoring systems.

  4. [Relationship between occupational stress and blood glucose, blood lipid, blood pressure of video display terminal operators].

    Science.gov (United States)

    Zhang, Xing; Song, Hui; Chen, Nan; Liu, He-rong; Zhu, Ling-qin; Zhang, Zhen-xiang; Wang, Ling

    2007-03-01

    To explore the relationship between occupational stress and blood glucose, Blood lipid and blood pressure. 108 video display terminals(VDT) operators who had the working experience were recruited to the study. The occupational stress indicator (OSI), the lever of blood glucose, cholesterol, triglyceride, lipoprotein of high density and lipoprotein of low density in serum were measured by using GOD-PAP, CHOD-PAP, GPO-PAP and PVS. The subjects were classified into three groups according to the score of occupational stress. The contents of blood glucose of low, middle and high level of stress groups were (3.39 +/- 1.24), (3.59 +/- 1.26), (2.54 +/- 0.94) mmol/L respectively (F = 7.324, P stress, the content of blood glucose decreased significantly (r = -0.376, P occupational stress, among video display terminals and it can be used as the index for estimating occupational stress.

  5. Personal glucose meters for detection and quantification of a broad range of analytes

    Science.gov (United States)

    Lu, Yi; Xiang, Yu

    2015-02-03

    A general methodology for the development of highly sensitive and selective sensors that can achieve portable, low-cost and quantitative detection of a broad range of targets using only a personal glucose meter (PGM) is disclosed. The method uses recognition molecules that are specific for a target agent, enzymes that can convert an enzyme substrate into glucose, and PGM. Also provided are sensors, which can include a solid support to which is attached a recognition molecule that permits detection of a target agent, wherein the recognition molecule specifically binds to the target agent in the presence of the target agent but not significantly to other agents as well as an enzyme that can catalyze the conversion of a substance into glucose, wherein the enzyme is attached directly or indirectly to the recognition molecule, and wherein in the presence of the target agent the enzyme can convert the substance into glucose. The disclosed sensors can be part of a lateral flow device. Methods of using such sensors for detecting target agents are also provided.

  6. Accuracy Evaluation of a CE-Marked Glucometer System for Self-Monitoring of Blood Glucose With Three Reagent Lots Following ISO 15197:2013.

    Science.gov (United States)

    Hehmke, Bernd; Berg, Sabine; Salzsieder, Eckhard

    2017-05-01

    Continuous standardized verification of the accuracy of blood glucose meter systems for self-monitoring after their introduction into the market is an important clinically tool to assure reliable performance of subsequently released lots of strips. Moreover, such published verification studies permit comparison of different blood glucose monitoring systems and, thus, are increasingly involved in the process of evidence-based purchase decision making.

  7. Recommending blood glucose monitors, a pharmacy perspective.

    Science.gov (United States)

    Carter, Alan

    2007-03-01

    Selection of what blood glucose monitoring system to utilize has become an issue for physicians, diabetes educators, pharmacists, and patients. The field of competing makes and models of blood glucose monitoring systems has become crowded, with manufacturers touting improvements in accuracy, ease of use/alternate site options, stored results capacity, software evaluation tools, and/or price point. Personal interviews of 12 pharmacists from community and academic practice settings about monitor preference, as well as results from a national survey of pharmacist recommendations, were compared to actual wholesale sales data to estimate the impact of such recommendations on final monitor selection by the patient. Accu-Chek monitors were recommended 34.65% of the time and represented 28.58% of sales, with a success rate of 82.48% of being the monitor selected. OneTouch monitors had 27.72% of recommendations but represented 31.43% of sales, indicating possible patient brand loyalty or formulary preference for that product. FreeStyle(R) monitors came in third for pharmacist recommendations and were selected by the patient 61.68% of the time when recommended. The category of "other monitor" choices was selected 60.89% of the time by patients given those suggestions. Included in the "other monitor" category was the new disposable monitor marketed as the Sidekick. Based on sales data provided, the Sidekick made up 2.87% of "other monitor" category sales, representing 68% of the "other monitor" segment. While patients frequently follow pharmacist monitoring system suggestions, the ultimate deciding factor is most often the final out-of-pocket cost to the patient. As a result, cost of supplies often becomes the most important determining factor in final monitor selection at the patient level. If the patient cannot afford to perform the recommended daily testing intervals, all other determining factors and suggestions become moot.

  8. Metabolic ketoacidosis with normal blood glucose: A rare complication of sodium–glucose cotransporter 2 inhibitors

    OpenAIRE

    Saad Ullah; Noman Khan; Hassan Zeb; Hassan Tahir

    2016-01-01

    Ketoacidosis is a significant and often a life-threatening complication of diabetes mellitus seen mostly in type 1 diabetes mellitus as well as occasionally in type 2 diabetes mellitus. Diabetic ketoacidosis usually manifests with high blood glucose more than 250 mg/dL, but euglycemic diabetic ketoacidosis is defined as ketoacidosis associated with blood glucose level less than 250 mg/dL. Normal blood glucose in such patients results in significant delay in diagnosis and management of diabeti...

  9. Correlation between blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients

    Directory of Open Access Journals (Sweden)

    Fildzah Rahman

    2016-06-01

    Full Text Available Diabetes Mellitus (DM is a syndrome in metabolism of carbohydrates which indicated by the increased level of blood glucose and also may increase salivary glucose levels. Oral ulcer has been frequently recognized in diabetic patients, which can be due to increased glucose in oral fluids and immune dysfunction. This study aimed to determine the correlation of blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients. Analytic observational study was carried out through the determination of blood glucose levels just by way of strip using a glucometer and salivary glucose levels with the method "GOD-PAP test enzymatic colorimetric". Oral ulcer was determined in presenting ulcer on 30 patients with DM. The results showed r = 0.228, which is higher salivary glucose levels followed by high levels of blood glucose, and intraoral examination of oral ulcer found in the whole sample and the most location commonly found in buccal mucosa and lingual. It was concluded that there is a correlation between blood glucose levels and salivary glucose levels, and glucose levels affect the occurrence of oral ulcer in patients with DM

  10. Blood glucose and nocturnal blood pressure in African and caucasian men: the SABPA study

    OpenAIRE

    Lammertyn, Leandi; Schutte, Aletta Elisabeth; Schutte, Rudolph

    2011-01-01

    To investigate the relationship between nocturnal blood pressure and chronically elevated blood glucose to determine if these elevated blood glucose concentrations contribute to a non-dipping blood pressure, especially in high-risk groups such as Africans. http://dx.doi.org/10.1016/j.diabres.2011.05.011

  11. Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Arati S. Panchbhai

    2012-07-01

    Full Text Available Objectives: There is alarming rise in number of people with diabetes mellitus over these years. If glucose in saliva is linked to glucose in blood it can be used to detect diabetes mellitus at an early stage. The present study is undertaken with the aim to assess the correlation of salivary glucose level with blood glucose level in people with diabetes mellitus. Material and Methods: For investigations, 2 sets of samples of people with diabetes and the age and sex matched non-diabetic subjects were recruited. The salivary glucose was analyzed in unstimulated whole saliva samples using glucose oxidase method. Pearson’s correlation coefficient test was applied to assess the correlation between salivary glucose level and blood glucose level. Results: The significant (P < 0.05 positive correlation of salivary glucose level and fasting blood glucose level was observed in people with uncontrolled diabetes in both the sets of samples.Conclusions: Although study suggests some potential for saliva as a marker in monitoring of diabetes mellitus, there are many aspects that need clarification before we reach to a conclusion.

  12. Ultrasonic Doppler blood flow meter for extracorporeal circulation

    Science.gov (United States)

    Dantas, Ricardo G.; Costa, Eduardo T.; Maia, Joaquim M.; Nantes Button, Vera L. d. S.

    2000-04-01

    In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient's body, in a procedure known as extracorporeal circulation (EC). During this procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2 MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53 mm). The experimental results using the developed flowmeter indicated a maximum deviation of 3.5% of full scale, while the blood flow estimator based in the rotation speed of the peristaltic pump presented deviations greater than 20% of full scale. This ultrasonic flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use.

  13. Metabolic ketoacidosis with normal blood glucose: A rare complication of sodium–glucose cotransporter 2 inhibitors

    Directory of Open Access Journals (Sweden)

    Saad Ullah

    2016-11-01

    Full Text Available Ketoacidosis is a significant and often a life-threatening complication of diabetes mellitus seen mostly in type 1 diabetes mellitus as well as occasionally in type 2 diabetes mellitus. Diabetic ketoacidosis usually manifests with high blood glucose more than 250 mg/dL, but euglycemic diabetic ketoacidosis is defined as ketoacidosis associated with blood glucose level less than 250 mg/dL. Normal blood glucose in such patients results in significant delay in diagnosis and management of diabetic ketoacidosis, thus increasing mortality and morbidity. We present a case of euglycemic diabetic ketoacidosis secondary to canagliflozin in a type 2 diabetic patient.

  14. Metabolic ketoacidosis with normal blood glucose: A rare complication of sodium–glucose cotransporter 2 inhibitors

    Science.gov (United States)

    Ullah, Saad; Khan, Noman; Zeb, Hassan; Tahir, Hassan

    2016-01-01

    Ketoacidosis is a significant and often a life-threatening complication of diabetes mellitus seen mostly in type 1 diabetes mellitus as well as occasionally in type 2 diabetes mellitus. Diabetic ketoacidosis usually manifests with high blood glucose more than 250 mg/dL, but euglycemic diabetic ketoacidosis is defined as ketoacidosis associated with blood glucose level less than 250 mg/dL. Normal blood glucose in such patients results in significant delay in diagnosis and management of diabetic ketoacidosis, thus increasing mortality and morbidity. We present a case of euglycemic diabetic ketoacidosis secondary to canagliflozin in a type 2 diabetic patient. PMID:27928503

  15. New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting, October 28, 2011.

    Science.gov (United States)

    Walsh, John; Roberts, Ruth; Vigersky, Robert A; Schwartz, Frank

    2012-03-01

    Glucose meters (GMs) are routinely used for self-monitoring of blood glucose by patients and for point-of-care glucose monitoring by health care providers in outpatient and inpatient settings. Although widely assumed to be accurate, numerous reports of inaccuracies with resulting morbidity and mortality have been noted. Insulin dosing errors based on inaccurate GMs are most critical. On October 28, 2011, the Diabetes Technology Society invited 45 diabetes technology clinicians who were attending the 2011 Diabetes Technology Meeting to participate in a closed-door meeting entitled New Criteria for Assessing the Accuracy of Blood Glucose Monitors. This report reflects the opinions of most of the attendees of that meeting. The Food and Drug Administration (FDA), the public, and several medical societies are currently in dialogue to establish a new standard for GM accuracy. This update to the FDA standard is driven by improved meter accuracy, technological advances (pumps, bolus calculators, continuous glucose monitors, and insulin pens), reports of hospital and outpatient deaths, consumer complaints about inaccuracy, and research studies showing that several approved GMs failed to meet FDA or International Organization for Standardization standards in postapproval testing. These circumstances mandate a set of new GM standards that appropriately match the GMs' analytical accuracy to the clinical accuracy required for their intended use, as well as ensuring their ongoing accuracy following approval. The attendees of the New Criteria for Assessing the Accuracy of Blood Glucose Monitors meeting proposed a graduated standard and other methods to improve GM performance, which are discussed in this meeting report.

  16. Corticosterone and Exogenous Glucose Alter Blood Glucose levels, Neurotoxicity, and Vascular Toxicity Produced by Methamphetamine.

    Science.gov (United States)

    Bowyer, John F; Tranter, Karen M; Sarkar, Sumit; George, Nysia I; Hanig, Joseph P; Kelly, Kimberly A; Michalovicz, Lindsay T; Miller, Diane B; O'Callaghan, James P

    2017-08-09

    Our previous studies have raised the possibility that altered blood glucose levels may influence and/or be predictive of methamphetamine (METH) neurotoxicity. This study evaluated the effects of exogenous glucose and corticosterone (CORT) pretreatment alone or in combination with METH on blood glucose levels and the neural and vascular toxicity produced. METH exposure consisted of four sequential injections of 5, 7.5, 10, and 10 mg/kg (2h between injections) D-METH. The three groups given METH in combination with saline, glucose (METH+Glucose), or CORT (METH+CORT) had significantly higher glucose levels compared to the corresponding treatment groups without METH except at 3 h after the last injection. At this last time point, the METH and METH+Glucose groups had lower levels than the non-METH groups, while the METH+CORT group did not. CORT alone or glucose alone did not significantly increase blood glucose. Mortality rates for the METH+CORT (40%) and METH+Glucose (44%) groups were substantially higher than the METH (< 10%) group. Additionally, METH+CORT significantly increased neurodegeneration above all other treatments (≈ 2.5-fold in the parietal cortex). Thus, maintaining elevated levels of glucose during METH exposure increases lethality and may exacerbate neurodegeneration. Neuroinflammation, specifically microglial activation, was associated with degenerating neurons in the parietal cortex and thalamus after METH exposure. The activated microglia in the parietal cortex were surrounding vasculature in most cases and the extent of microglial activation was exacerbated by CORT pretreatment. Our findings implicate elevated blood levels of glucose and hyperthermia in METH-induced neurotoxicity, neurovascular damage, and lethality, and that acute elevation of CORT exacerbates both neurotoxicity and neuroinflammation. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. Optical coherence tomography for blood glucose monitoring through signal attenuation

    Science.gov (United States)

    De Pretto, Lucas R.; Yoshimura, Tania M.; Ribeiro, Martha S.; de Freitas, Anderson Z.

    2016-03-01

    Development of non-invasive techniques for glucose monitoring is crucial to improve glucose control and treatment adherence in patients with diabetes. Hereafter, Optical Coherence Tomography (OCT) may offer a good alternative for portable glucometers, since it uses light to probe samples. Changes in the object of interest can alter the intensity of light returning from the sample and, through it, one can estimate the sample's attenuation coefficient (μt) of light. In this work, we aimed to explore the behavior of μt of mouse's blood under increasing glucose concentrations. Different samples were prepared in four glucose concentrations using a mixture of heparinized blood, phosphate buffer saline and glucose. Blood glucose concentrations were measured with a blood glucometer, for reference. We have also prepared other samples diluting the blood in isotonic saline solution to check the effect of a higher multiple-scattering component on the ability of the technique to differentiate glucose levels based on μt. The OCT system used was a commercial Spectral Radar OCT with 930 nm central wavelength and spectral bandwidth (FWHM) of 100 nm. The system proved to be sensitive for all blood glucose concentrations tested, with good correlations with the obtained attenuation coefficients. A linear tendency was observed, with an increase in attenuation with higher values of glucose. Statistical difference was observed between all groups (p<0.001). This work opens the possibility towards a non-invasive diagnostic modality using OCT for glycemic control, which eliminates the use of analytes and/or test strips, as in the case with commercially available glucometers.

  18. Performance Evaluation and Labeling Comprehension of a New Blood Glucose Monitoring System with Integrated Information Management

    Science.gov (United States)

    List, Susan M; Starks, Nykole; Baum, John; Greene, Carmine; Pardo, Scott; Parkes, Joan L; Schachner, Holly C; Cuddihy, Robert

    2011-01-01

    Background This study evaluated performance and product labeling of CONTOUR® USB, a new blood glucose monitoring system (BGMS) with integrated diabetes management software and a universal serial bus (USB) port, in the hands of untrained lay users and health care professionals (HCPs). Method Subjects and HCPs tested subject's finger stick capillary blood in parallel using CONTOUR USB meters; deep finger stick blood was tested on a Yellow Springs Instruments (YSI) glucose analyzer for reference. Duplicate results by both subjects and HCPs were obtained to assess system precision. System accuracy was assessed according to International Organization for Standardization (ISO) 15197:2003 guidelines [within ±15 mg/dl of mean YSI results (samples <75 mg/dl) and ±20% (samples ≥75 mg/dl)]. Clinical accuracy was determined by Parkes error grid analysis. Subject labeling comprehension was assessed by HCP ratings of subject proficiency. Key system features and ease-of-use were evaluated by subject questionnaires. Results All subjects who completed the study (N = 74) successfully performed blood glucose measurements, connected the meter to a laptop computer, and used key features of the system. The system was accurate; 98.6% (146/148) of subject results and 96.6% (143/148) of HCP results exceeded ISO 15197:2003 criteria. All subject and HCP results were clinically accurate (97.3%; zone A) or associated with benign errors (2.7%; zone B). The majority of subjects rated features of the BGMS as “very good” or “excellent.” Conclusions CONTOUR USB exceeded ISO 15197:2003 system performance criteria in the hands of untrained lay users. Subjects understood the product labeling, found the system easy to use, and successfully performed blood glucose testing. PMID:22027308

  19. A data driven nonlinear stochastic model for blood glucose dynamics.

    Science.gov (United States)

    Zhang, Yan; Holt, Tim A; Khovanova, Natalia

    2016-03-01

    The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles.

  20. The business of self-monitoring of blood glucose: a market profile.

    Science.gov (United States)

    Hughes, Mark D

    2009-09-01

    The market for self-monitoring of blood glucose (SMBG) approached $8.8 billion worldwide in 2008. Yet despite dramatic double-digit growth in sales of SMBG products since 1980, the business is now facing declining prices and slower dollar growth. Given that SMBG meters and test strips are viewed by consumers and insurers as essentially generic products, it will be extremely challenging for new market entrants to displace well-entrenched existing competitors without a truly innovative technology. Also, in the face of declining glucose test strip prices, market expansion can only occur through identification of more of the undiagnosed diabetes population and convincing existing diabetes patients to adopt glucose testing or to test more frequently. Ultimately, a combination of technology innovations, patient education, and economic incentives may be needed to significantly expand the SMBG market and build sustainable long-term dollar growth for SMBG vendors.

  1. Prediction methods for blood glucose concentration design, use and evaluation

    CERN Document Server

    Jørgensen, John; Renard, Eric; Re, Luigi

    2016-01-01

    This book tackles the problem of overshoot and undershoot in blood glucose levels caused by delay in the effects of carbohydrate consumption and insulin administration. The ideas presented here will be very important in maintaining the welfare of insulin-dependent diabetics and avoiding the damaging effects of unpredicted swings in blood glucose – accurate prediction enables the implementation of counter-measures. The glucose prediction algorithms described are also a key and critical ingredient of automated insulin delivery systems, the so-called “artificial pancreas”. The authors address the topic of blood-glucose prediction from medical, scientific and technological points of view. Simulation studies are utilized for complementary analysis but the primary focus of this book is on real applications, using clinical data from diabetic subjects. The text details the current state of the art by surveying prediction algorithms, and then moves beyond it with the most recent advances in data-based modeling o...

  2. Blood glucose rise following prenatal vitamins in gestational diabetes.

    Science.gov (United States)

    Sparks, S P; Jovanovic-Peterson, L; Peterson, C M

    1993-10-01

    Optimal outcome of gestational diabetes mellitus (GDM) is directly related to glucose control of the mother. If prenatal vitamins cause a large glycemic excursion, then the best prenatal vitamin would be one that produces the lowest blood glucose. Nine GDM women participated in two, 8-day test periods. Each subject ingested one of six prenatal vitamin-mineral preparations, a placebo, or a sucrose capsule, in random order. Blood glucose was determined by the One Touch System at 0, 30, and 60 minutes. The sucrose capsule contained 1 g sucrose (equivalent to highest glucose/carbohydrate content of any prenatal vitamin). The placebo contained 1 g table salt in the same color capsule. Relative glycemic index (RGI, defined as the area under glucose curve for the test substance divided by the area under glucose curve for 1 g sucrose) and maximum rise of blood glucose above time 0 were calculated for each preparation. RGI was significantly elevated for all vitamins: TRN 3.86, Natalins Rx 3.00, Filibon Forte 2.16, Prenatal Formula 2.10, Materna 1.66, Placebo 1.33, Stuartnatal 1 + 1 1.16. Two thousand mg vitamin C (n = 4) resulted in an RGI of 1.37. In conclusion, ingestion of prenatal vitamins produces a rise in blood glucose greater than that seen following ingestion of sucrose equal to the carbohydrate content of prenatal vitamins. The cause of the blood glucose rise is not known, but it would appear prudent to prescribe a prenatal vitamin with a low RGI.

  3. Validation of a portable hand-held whole-blood ketone meter for use in cats.

    Science.gov (United States)

    Weingart, Christiane; Lotz, Fabian; Kohn, Barbara

    2012-03-01

    Urinary dipsticks are the most frequent method used for screening of ketones in animals, but this method has many drawbacks. In human medicine, portable meters that measure ketones in whole blood have largely replaced urinary dipsticks. The aim of this prospective study was to validate a portable whole-blood ketone meter for use in cats. Sixty-two cats (11 clinically healthy, 51 with diabetes mellitus) were included in the study. The concentration of β-hydroxybuyrate (β-HB) was measured in venous and capillary blood with a hand-held ketone meter (Precision Xceed; assay range 0-8 mmol/L) and compared with a spectrophotometric method. Precision, accuracy, and the effects of hematocrit and anticoagulants were evaluated. Between-run precision using low- and high-concentration control solutions was 8.1% and 2.6%, respectively; within-run coefficient of variation determined using 12 feline blood samples was 2.8%. In the 62 cats, β-HB concentrations measured with the portable ketone meter ranged from 0-7.4 mmol/L (median 0.9 mmol/L). When β-HB concentrations measured by the portable meter were 4.0 mmol/L were lower than those obtained by the reference method in 20 of 24 cats (83%). There was good correlation between capillary and venous measurements. Results were not affected by hematocrits from 0.17 to 0.50 L/L, but EDTA was not a suitable anticoagulant. Measurement of β-HB concentration in peripheral or capillary blood by an easy-to-use portable ketone meter was suitable for detecting ketonemia in cats. Underestimation of β-HB concentration was observed at higher values, but results were sufficiently high to aid in diagnosing diabetic ketoacidosis. © 2012 American Society for Veterinary Clinical Pathology.

  4. Body Fat Content, Distribution and Blood Glucose Concentration ...

    African Journals Online (AJOL)

    Changes in blood glucose level are accompanied by changes in insulin levels which may result to insulin resistance. Raised blood ... To overcome these problems information about causes of diabetes ... Department of Food Technology, Nutrition and Consumer Science; .... determine the significance association between.

  5. Analytical model for real time, noninvasive estimation of blood glucose level.

    Science.gov (United States)

    Adhyapak, Anoop; Sidley, Matthew; Venkataraman, Jayanti

    2014-01-01

    The paper presents an analytical model to estimate blood glucose level from measurements made non-invasively and in real time by an antenna strapped to a patient's wrist. Some promising success has been shown by the RIT ETA Lab research group that an antenna's resonant frequency can track, in real time, changes in glucose concentration. Based on an in-vitro study of blood samples of diabetic patients, the paper presents a modified Cole-Cole model that incorporates a factor to represent the change in glucose level. A calibration technique using the input impedance technique is discussed and the results show a good estimation as compared to the glucose meter readings. An alternate calibration methodology has been developed that is based on the shift in the antenna resonant frequency using an equivalent circuit model containing a shunt capacitor to represent the shift in resonant frequency with changing glucose levels. Work under progress is the optimization of the technique with a larger sample of patients.

  6. Finger temperature controller for non-invasive blood glucose measurement

    Science.gov (United States)

    Zhang, Xiqin; Ting, Choon Meng; Yeo, Joon Hock

    2010-11-01

    Blood glucose level is an important parameter for doctors to diagnose and treat diabetes. The Near-Infra-Red (NIR) spectroscopy method is the most promising approach and this involves measurement on the body skin. However it is noted that the skin temperature does fluctuate with the environmental and physiological conditions and we found that temperature has important influences on the glucose measurement. In-vitro and in-vivo investigations on the temperature influence on blood glucose measurement have been carried out. The in-vitro results show that water temperature has significant influence on water absorption. Since 90% of blood components are water, skin temperature of measurement site has significant influence on blood glucose measurement. Also the skin temperature is related to the blood volume, blood volume inside capillary vessels changes with skin temperature. In this paper the relationship of skin temperature and signal from the skin and inside tissue was studied at different finger temperatures. Our OGTT (oral glucose tolerance test) trials results show the laser signals follow the skin temperature trend and the correlation of signal and skin temperature is much stronger than the correlation of signal and glucose concentration. A finger heater device is designed to heat and maintain the skin temperature of measurement site. The heater is controlled by an electronic circuit according to the skin temperature sensed by a thermocouple that is put close to the measurement site. In vivo trials were carried out and the results show that the skin temperature significantly influences the signal fluctuations caused by pulsate blood and the average signal value.

  7. Inhaled insulin for controlling blood glucose in patients with diabetes

    Directory of Open Access Journals (Sweden)

    Bernard L Silverman

    2008-01-01

    Full Text Available Bernard L Silverman1, Christopher J Barnes2, Barbara N Campaigne3, Douglas B Muchmore31Alkermes, Inc, Cambridge, MA, USA; 2i3 Statprobe, Ann Arbor, MI; 3Eli Lilly and Company, Indianapolis, IN, USAAbstract: Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients from achieving optimal blood glucose control. The development and utilization of inhaled insulin as a novel insulin delivery system may positively influence patient treatment adherence and optimal glycemic control, potentially leading to a reduction in cardiovascular complications in patients with diabetes.Keywords: diabetes, inhaled insulin, cardiovascular disease, blood glucose

  8. Effects of MDMA on blood glucose levels and brain glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Soto-Montenegro, M.L.; Vaquero, J.J.; Garcia-Barreno, P.; Desco, M. [Hospital General Universitario Gregorio Maranon, Laboratorio de Imagen, Medicina Experimental, Madrid (Spain); Arango, C. [Hospital General Gregorio Maranon, Departamento de Psiquiatria, Madrid (Spain); Ricaurte, G. [Johns Hopkins University School of Medicine, Department of Neurology, Baltimore, MD (United States)

    2007-06-15

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  9. Discrepancies Between Blood Glucose and Interstitial Glucose-Technological Artifacts or Physiology: Implications for Selection of the Appropriate Therapeutic Target.

    Science.gov (United States)

    Siegmund, Thorsten; Heinemann, Lutz; Kolassa, Ralf; Thomas, Andreas

    2017-07-01

    For decades, the major source of information used to make therapeutic decisions by patients with diabetes has been glucose measurements using capillary blood samples. Knowledge gained from clinical studies, for example, on the impact of metabolic control on diabetes-related complications, is based on such measurements. Different to traditional blood glucose measurement systems, systems for continuous glucose monitoring (CGM) measure glucose in interstitial fluid (ISF). The assumption is that glucose levels in blood and ISF are practically the same and that the information provided can be used interchangeably. Thus, therapeutic decisions, that is, the selection of insulin doses, are based on CGM system results interpreted as though they were blood glucose values. We performed a more detailed analysis and interpretation of glucose profiles obtained with CGM in situations with high glucose dynamics to evaluate this potentially misleading assumption. Considering physical activity, hypoglycemic episodes, and meal-related differences between glucose levels in blood and ISF uncover clinically relevant differences that can make it risky from a therapeutic point of view to use blood glucose for therapeutic decisions. Further systematic and structured evaluation as to whether the use of ISF glucose is more safe and efficient when it comes to acute therapeutic decisions is necessary. These data might also have a higher prognostic relevance when it comes to long-term metabolic consequences of diabetes. In the long run, it may be reasonable to abandon blood glucose measurements as the basis for diabetes management and switch to using ISF glucose as the appropriate therapeutic target.

  10. Measurement of capillary blood glucose concentrations by pet owners: a new tool in the management of diabetes mellitus.

    Science.gov (United States)

    Casella, Martina; Wess, Gerhard; Reusch, Claudia E

    2002-01-01

    Recently a new method for capillary blood sampling from the ears of dogs and cats was described, which allows the measurement of glucose concentration by means of portable glucose meters. The authors of this report evaluated the suitability of this method for use by pet owners and the potential technical problems. The owners of seven healthy dogs and seven healthy cats were asked to perform two glucose curves (measuring blood glucose concentration every 2 hours for a total of 12 hours). All dog owners and three cat owners were able to perform a reliable blood glucose curve. The most frequently encountered problems were inadequate formation of a blood drop due to excessive digital pressure on the pinna, repeatedly depressing the plunger of the lancet device instead of allowing the negative pressure to slowly build up, and failure to fill the test strip up to the mark. The authors conclude that these steps of the procedure need to be stressed during technique demonstration and that home monitoring of blood glucose concentrations may serve as a new tool in the management of diabetic dogs and cats.

  11. Glycated hemoglobin in camel: Minimal correlation with blood glucose level

    Directory of Open Access Journals (Sweden)

    Bazzi Mohammad D.

    2013-01-01

    Full Text Available Glucose and glycated hemoglobin (Hb in the blood of camel (Camelus dromedarius and cow (Bos taurus were analyzed and compared with human values. Camel displayed high blood glucose concentration (9.7±2.8 mM but a low level of glycated-Hb (3.4± 0.23%.Cow blood samples did not show sufficient variations in glucose concentrations (5.7±0.73 mM or glycated Hb levels (3.2± 0.11% compared to human values. The low glycation of camel Hb at higher glucose concentrations suggest that certain factors protect the Hb from glycation at high glucose concentrations. Camel Hb also exhibited a higher electrophoretic mobility than normal hemoglobin of human or cow. Camel Hb migrated at a rate corresponding to that of human Hb-C. Bioinformatics tools were used to explore the biochemical basis for the difference in camel Hb migratory position and its apparent resistance to glycation.

  12. Turnover rate of blood glucose in diabetic KK mice.

    Science.gov (United States)

    Fujimoto, K; Sakaguchi, T; Ui, M

    1981-07-01

    Metabolic rate constants for blood glucose turnover were estimated based on the decay of [U-14C, 6-3H]glucose injected intravenously in genetically diabetic KK mice. Comparison was made with the rate constants similarly obtained with non-diabetic and streptozotocin-induced diabetic ICR mice. Recycling of blood glucose via the Cori cycle, as estimated from the difference in the decay rate between 14C and 3H, was more active in KK mice than in non-diabetic and diabetic ICR mice. The Cori cycle activity was reduced by beta-adrenergic blockade in KK mice and was enhanced by alpha-blockade in ICR mice. It is concluded that predominance of beta-adrenergic functions in KK mice is responsible for activation of the Cori cycle as one of the mechanisms for metabolic resistance to endogenous insulin.

  13. [Analysis of blood glucose levels in 746 cases of schistosomiasis].

    Science.gov (United States)

    Hou, An-Ming; Wu, Guo-Hua; Zhang, Gui-Lin

    2011-04-01

    The levels of blood glucose of 746 inpatients with chronic or advanced schistosomiasis were assayed last 3 years and the results were analyzed. There was no significant difference between the pure chronic or advanced schistosomiasis patients and normal population. However, there was a significant difference between the chronic or advanced schistosomiasis patients with viral hepatitis and normal population.

  14. Impact of diet composition on blood glucose regulation

    NARCIS (Netherlands)

    Russell, W.R.; Baka, A.; Bjorck, I.; Delzenne, N.; Gao, D.; Griffiths, H.R.; Hadjilucas, E.; Juvonen, K.; Lahtinen, S.; Lansink, M.; van Loon, L.; Mykkanen, H.; Ostman, E.; Riccardi, G.; Vinoy, S.; Weickert, M.O.

    2013-01-01

    Abstract Nutritional management of blood glucose levels is a strategic target in the prevention and management of type 2 diabetes mellitus (T2DM). To implement such an approach it is essential to understand the effect of food on glycaemic regulation and on the underlying metabolic derangements. This

  15. Analysis article on the performance analysis of the OneTouch UltraVue blood glucose monitoring system.

    Science.gov (United States)

    Solnica, Bogdan

    2009-09-01

    In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch UltraVue blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients.

  16. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  17. Noninvasive miniaturized mass-flow meter using a curved cannula for implantable axial flow blood pump.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2011-01-01

    Blood flow should be measured to monitor conditions of patients with implantable artificial hearts continuously and noninvasively. We have developed a noninvasive miniaturized mass-flow meter using a curved cannula for an axial flow blood pump. The mass-flow meter utilized centrifugal force generated by the mass-flow rate in the curved cannula. Two strain gauges served as sensors. Based on the numerical analysis, the first gauge, attached to the curved area, measured static pressure and centrifugal force, and the second, attached to the straight area, measured static pressure for static pressure compensation. The mass-flow rate was determined by the differences in output from the two gauges. To compensate for the inertia force under the pulsatile flow, a 0.75-Hz low-pass filter was added to the electrical circuit. In the evaluation tests, numerical analysis and an actual measurement test using bovine blood were performed to evaluate the measurement performances. As a result, in the numerical analysis, the relationship between the differential pressure caused by centrifugal force and the flow rate was verified. In the actual measurement test, measurement error was less than ± 0.5 L/min, and the time delay was 0.12 s. We confirmed that the developed mass-flow meter was able to measure mass-flow rate continuously and noninvasively.

  18. Influence of Artificial Sweetener on Human Blood Glucose Concentration

    Directory of Open Access Journals (Sweden)

    Ilse Skokan

    2007-01-01

    Full Text Available Artificial sweeteners, such as saccharin or cyclamic acid are synthetically manufactured sweetenings. Known for their low energetic value they serve especially diabetic and adipose patients as sugar substitutes. It has been hypothesized that the substitution of sugar with artificial sweeteners may induce a decrease of the blood glucose. The aim of this study was to determine the reliability of this hypothesis by comparing the influence of regular table sugar and artificial sweeteners on the blood glucose concentration. In this pilot-study 16 patients were included suffering from adiposity, pre-diabetes and hypertension. In the sense of a cross-over design, three test trials were performed at intervals of several weeks. Each trial was followed by a test free interval. Within one test trial each patient consumed 150 ml test solution (water that contained either 6 g of table sugar (“Kandisin” with sweetener free serving as control group. Tests were performed within 1 hr after lunch to ensure conditions comparable to patients having a desert. Every participant had to determine their blood glucose concentration immediately before and 5, 15, 30 and 60 minutes after the intake of the test solution. For statistics an analysis of variance was performed. The data showed no significant changes in the blood glucose concentration. Neither the application of sugar (F4;60 = 1.645; p = .175 nor the consumption of an artificial sweetener (F2.068;31.023 = 1.551; p > .05 caused significant fluctuations in the blood sugar levels. Over a time frame of 60 minutes in the control group a significant decrease of the blood sugar concentration was found (F2.457;36.849 = 4.005; p = .020 as a physiological reaction during lunch digestion.

  19. Glucose predictability, blood capillary permeability, and glucose utilization rate in subcutaneous, skeletal muscle, and visceral fat tissues.

    Science.gov (United States)

    Koutny, Tomas

    2013-11-01

    This study suggests an approach for the comparison and evaluation of particular compartments with modest experimental setup costs. A glucose level prediction model was used to evaluate the compartment's glucose transport rate across the blood capillary membrane and the glucose utilization rate by the cells. The glucose levels of the blood, subcutaneous tissue, skeletal muscle tissue, and visceral fat were obtained in experiments conducted on hereditary hypertriglyceridemic rats. After the blood glucose level had undergone a rapid change, the experimenter attempted to reach a steady blood glucose level by manually correcting the glucose infusion rate and maintaining a constant insulin infusion rate. The interstitial fluid glucose levels of subcutaneous tissue, skeletal muscle tissue, and visceral fat were evaluated to determine the reaction delay compared with the change in the blood glucose level, the interstitial fluid glucose level predictability, the blood capillary permeability, the effect of the concentration gradient, and the glucose utilization rate. Based on these data, the glucose transport rate across the capillary membrane and the utilization rate in a particular tissue were determined. The rates obtained were successfully verified against positron emission tomography experiments. The subcutaneous tissue exhibits the lowest and the most predictable glucose utilization rate, whereas the skeletal muscle tissue has the greatest glucose utilization rate. In contrast, the visceral fat is the least predictable and has the shortest reaction delay compared with the change in the blood glucose level. The reaction delays obtained for the subcutaneous tissue and skeletal muscle tissue were found to be approximately equal using a metric based on the time required to reach half of the increase in the interstitial fluid glucose level. © 2013 Published by Elsevier Ltd.

  20. How to Safely Use Glucose Meters and Test Strips for Diabetes

    Science.gov (United States)

    ... These pre-owned strips may be sold at lower prices when compared to new strips. For instance, you ... if you are using your device correctly. Do quality control checks of your ... Understand what the meter display means. Be sure you know how high and low ...

  1. A Deep Learning Approach to Diabetic Blood Glucose Prediction

    Directory of Open Access Journals (Sweden)

    Hrushikesh N. Mhaskar

    2017-07-01

    Full Text Available We consider the question of 30-min prediction of blood glucose levels measured by continuous glucose monitoring devices, using clinical data. While most studies of this nature deal with one patient at a time, we take a certain percentage of patients in the data set as training data, and test on the remainder of the patients; i.e., the machine need not re-calibrate on the new patients in the data set. We demonstrate how deep learning can outperform shallow networks in this example. One novelty is to demonstrate how a parsimonious deep representation can be constructed using domain knowledge.

  2. Insulin overlapping in whole blood FTIR spectroscopy in blood glucose measurements

    Science.gov (United States)

    Romo-Cárdenas, G.; Sánchez-López, J. de D.; Luque, P. A.; Cosío-León, M.; Nieto-Hipólito, Juan I.; Vázquez-Briseño, Mabel

    For the last decade, several studies on mid-IR spectroscopy for blood glucose quantification have not considered the compounds involved in the glucose regulation mechanism, in which insulin plays an important role. This work shows how insulin overlaps in the same mid-IR region in which glucose is quantified. This optical absorption interference is an important factor to be considered for this type of studies, in the scope of whole blood modeling for spectroscopy applications and the possible use of computer based metrics.

  3. Effect of insulin in combination with selenium on blood glucose and GLUT4 expression in skeletal muscle of streptozotocin-induced diabetic rats

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Objective To evaluate the effect of low-dose insulin [1 U/(kg·d)] in combination with selenium [180 g/(kg·d)] on general physiological parameters and glucose transporter (GLUT4) level in skeletal muscle of streptozotocin (STZ)-induced diabetic rats. Methods Diabetic rats were treated with insulin,selenium,and insulin and selenium in combination for four weeks. The level of blood glucose was determined using One Touch SureStep Blood Glucose meter and the level of GLUT4 in skeletal muscle was examined by immu...

  4. The Diabetes Assistant: A Smartphone-Based System for Real-Time Control of Blood Glucose

    Directory of Open Access Journals (Sweden)

    Patrick Keith-Hynes

    2014-11-01

    Full Text Available Type 1 Diabetes Mellitus (T1DM is an autoimmune disease in which the insulin-producing beta cells of the pancreas are destroyed and insulin must be injected daily to enable the body to metabolize glucose. Standard therapy for T1DM involves self-monitoring of blood glucose (SMBG several times daily with a blood glucose meter and injecting insulin via a syringe, pen or insulin pump. An “Artificial Pancreas” (AP is a closed-loop control system that uses a continuous glucose monitor (CGM, an insulin pump and an internal algorithm to automatically manage insulin infusion to keep the subject’s blood glucose within a desired range. Although no fully closed-loop AP systems are currently commercially available there are intense academic and commercial efforts to produce safe and effective AP systems. In this paper we present the Diabetes Assistant (DiAs, an ultraportable AP research platform designed to enable home studies of Closed Loop Control (CLC of blood glucose in subjects with Type 1 Diabetes Mellitus. DiAs consists of an Android (Google Inc., Mountain View, CA, USA smartphone equipped with communication, control and user interface software wirelessly connected to a continuous glucose monitor and insulin pump. The software consists of a network of mobile applications with well-defined Application Programming Interfaces (APIs running atop an enhanced version of Android with non-essential elements removed. CLC and safety applications receive real-time data from the CGM and pump, estimate the patient’s metabolic state and risk of hypo- and hyperglycemia, adjust the insulin infusion rate, raise alarms as needed and transmit de-identified data to a secure remote server. Some applications may be replaced by researchers wishing to conduct outpatient ambulatory studies of novel Closed Loop Control, Safety or User Interface modules. Over the past three years the DiAs platform has been used in a series of AP clinical trials sponsored by the National

  5. Determinants of Sensorimotor Function and Blood Glucose Among Chinese People Aged 50–74 Years

    Directory of Open Access Journals (Sweden)

    Jian-Wei Lin

    2014-06-01

    Conclusion: Our findings suggested that Chinese elderly who have a high blood glucose concentration may also have a worse status in near vision. Sex, resident area, income, education, and BMI were significant predictors of sensorimotor function and blood glucose.

  6. Blood glucose rise after lactose tolerance testing in infants.

    Science.gov (United States)

    Paige, D M; Mellits, E D; Chiu, F Y; Davis, L; Bayless, T M; Cordano, A

    1978-02-01

    Lactose tolerance tests are used clinically to screen children and infants. It is assumed that absorption of a lactose challenge in infants would occur in a predictable pattern prior to weaning. Twenty-one infants from 3 to 12 months of age were studied. The maximum blood glucose rise over fasting levels ranged from 11.0 to 62.0 mg/100 ml; the mean was 32.6 mg/100 ml. Six infants had a maximum rise of less than 20 mg/100 ml. Eleven infants (52%) had a maximum rise of greater than 30 mg/100 ml. Signs of intolerance were not noted in any subject. Weight and length were normally disturbed. Results indicate the variance in glucose rise existing within a population of infants growing normally and consuming milk. Gastric emptying, digestion, and absorption may influence the blood glucose rise after a lactose test. Established glucose levels used as an index to lactose absorption in older children and adults may not accurately reflect lactase activity in infants.

  7. Fructo-oligosaccharide effects on blood glucose: an overview.

    Science.gov (United States)

    Costa, Graciana Teixeira; Guimarães, Sergio Botelho; Sampaio, Helena Alves de Carvalho

    2012-03-01

    To identify the current status of scientific knowledge in fructo-oligosaccharides (FOS), non-conventional sugars that play an important role in glycemia control. We performed a search for scientific articles in MEDLINE and LILACS databases, from January 1962 to December 2011, using English/Portuguese key words: "blood glucose/glicemia", "prebiotics/prebióticos" and "dietary fiber/fibras na dieta". From an initial number of 434 references, some repeated, 43 references published from 1962 to 2011 were included in this study. The selected texts were distributed in three topics: (1) metabolism of FOS, (2) FOS and experimental studies involving glucose and (3) human studies involving glucose and FOS. Five studies have shown that the use of FOS reduces the fecal content and increases intestinal transit time. Experimental studies have shown that dietary supplementation with high doses (60 g/Kg) of propionate, a short-chain fatty acid decreased glycemia. The use of lower doses (3 g/kg) did not produce the same results. Study in subjects with diabetes type II showed that the addition of 8 grams of FOS in the diet for 14 days, caused a reduction in serum glucose. In another study with healthy subjects, there were no changes in glycemic control. This review demonstrates that consumption of FOS has a beneficial influence on glucose metabolism. The controversies appear to be due to inadequate methodological designs and/or the small number of individuals included in some studies.

  8. Microbiosensors for determination of glucose in the blood sample

    Institute of Scientific and Technical Information of China (English)

    金鹏; 谭久彬; 孙凯

    2002-01-01

    Describes the general design of Microbiosensors for determination of glucose in blood sample for medical purpose as an important branch of medical analysis instrument discusses the fabrication of microbiosensors. By the technology of microfabrication, self-assembled monolayers (SAMs) and enzyme immobilization, stresses their properties, such as improvement in system efficiency, shorter analysis time reduction of reagent waste and reduction of device sizes, which makes them suitable for bed-side monitor of emergency patients.

  9. Non-invasive Blood Glucose Quantification Using a Hybrid Sensor

    Directory of Open Access Journals (Sweden)

    Sundararajan JAYAPAL

    2009-02-01

    Full Text Available Diabetes Mellitus is a group of metabolic diseases characterized by high blood sugar (glucose levels which result from defects in insulin secretion. It is very important for the diabetics and normal people to have a correct blood glucose level. The HbA1c test is the most preferred test by renowned doctors for glucose quantification. But this test is an invasive one. At present, there are many available techniques for this purpose but these are mostly invasive or minimally non-invasive and most of these are under research. Among the different methods available, the photo acoustic (PA methods provide a reliable solution since the acoustical energy loss is much less compared to the optical or other techniques. Here a novel framework is presented for blood glucose level measurement using a combination of the HbA1c test and a PA method to get an absolutely consistent and precise, non-invasive technique. The setup uses a pulsed laser diode with pulse duration of 5-15 ns and at a repetition rate of 10 Hz as the source. The detector setup is based on the piezoelectric detection. It consists of a ring detector that includes two double ring sensors that are attached to the ring shaped module that can be worn around the finger. The major aim is to detect the photo acoustic signals from the glycated hemoglobin with the least possible error. The proposed monitoring system is designed with extreme consideration to precision and compatibility with the other computing devices. The results obtained in this research have been studied and analyzed by comparing these with those of in-vitro techniques like the HPLC. The comparison has been plotted and it shows a least error. The results also show a positive drive for using this concept as a basis for future extension in quantifying the other blood components.

  10. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin......-blockade group vs. the control group, hormones, metabolites, VO(2), and RER followed the same pattern of changes in ACE-blockade and control groups during exercise. Splanchnic blood flow (at rest: 1.67 +/- 0.12, ACE blockade; 1.59 +/- 0.18 l/min, control) decreased during moderate exercise (0.78 +/- 0.07, ACE...

  11. Peripheral Blood Transcriptomic Signatures of Fasting Glucose and Insulin Concentrations.

    Science.gov (United States)

    Chen, Brian H; Hivert, Marie-France; Peters, Marjolein J; Pilling, Luke C; Hogan, John D; Pham, Lisa M; Harries, Lorna W; Fox, Caroline S; Bandinelli, Stefania; Dehghan, Abbas; Hernandez, Dena G; Hofman, Albert; Hong, Jaeyoung; Joehanes, Roby; Johnson, Andrew D; Munson, Peter J; Rybin, Denis V; Singleton, Andrew B; Uitterlinden, André G; Ying, Saixia; Melzer, David; Levy, Daniel; van Meurs, Joyce B J; Ferrucci, Luigi; Florez, Jose C; Dupuis, Josée; Meigs, James B; Kolaczyk, Eric D

    2016-12-01

    Genome-wide association studies (GWAS) have successfully identified genetic loci associated with glycemic traits. However, characterizing the functional significance of these loci has proven challenging. We sought to gain insights into the regulation of fasting insulin and fasting glucose through the use of gene expression microarray data from peripheral blood samples of participants without diabetes in the Framingham Heart Study (FHS) (n = 5,056), the Rotterdam Study (RS) (n = 723), and the InCHIANTI Study (Invecchiare in Chianti) (n = 595). Using a false discovery rate q fasting glucose and 433 transcripts associated with fasting insulin levels after adjusting for age, sex, technical covariates, and complete blood cell counts. Among the findings, circulating IGF2BP2 transcript levels were positively associated with fasting insulin in both the FHS and RS. Using 1000 Genomes-imputed genotype data, we identified 47,587 cis-expression quantitative trait loci (eQTL) and 6,695 trans-eQTL associated with the 433 significant insulin-associated transcripts. Of note, we identified a trans-eQTL (rs592423), where the A allele was associated with higher IGF2BP2 levels and with fasting insulin in an independent genetic meta-analysis comprised of 50,823 individuals. We conclude that integration of genomic and transcriptomic data implicate circulating IGF2BP2 mRNA levels associated with glucose and insulin homeostasis. © 2016 by the American Diabetes Association.

  12. Analysis of algorithms for intensive care unit blood glucose control.

    Science.gov (United States)

    Bequette, B Wayne

    2007-11-01

    Intensive care unit (ICU) blood glucose control algorithms were reviewed and analyzed in the context of linear systems theory and classical feedback control algorithms. Closed-loop performance was illustrated by applying the algorithms in simulation studies using an in silico model of an ICU patient. Steady-state and dynamic input-output analysis was used to provide insight about controller design and potential closed-loop performance. The proportional-integral-derivative, columnar insulin dosing (CID, Glucommander-like), and glucose regulation for intensive care patients (GRIP) algorithms were shown to have similar features and performance. The CID strategy is a time-varying proportional-only controller (no integral action), whereas the GRIP algorithm is a nonlinear controller with integral action. A minor modification to the GRIP algorithm was suggested to improve the closed-loop performance. Recommendations were made to guide control theorists on important ICU control topics worthy of further study.

  13. Mibefradil reduces blood glucose concentration in db/db mice

    Directory of Open Access Journals (Sweden)

    Yujie Lu

    2014-01-01

    Full Text Available OBJECTIVE: Numerous recent studies suggest that abnormal intracellular calcium concentration ([Ca2+]i is a common defect in diabetic animal models and patients. Abnormal calcium handling is an important mechanism in the defective pancreatic β-cell function in type 2 diabetes. T-type Ca2+ channel antagonists lower blood glucose in type 2 diabetes, but the mechanism remains unknown. METHODS: We examined the effect of the Ca2+ channel antagonist mibefradil on blood glucose in male db/db mice and phenotypically normal heterozygous mice by intraperitoneal injection. RESULTS: Mibefradil (15 mg/kg, i.p., b.i.d. caused a profound reduction of fasting blood glucose from 430.92±20.46 mg/dl to 285.20±5.74 mg/dl in three days. The hypoglycemic effect of mibefradil was reproduced by NNC 55-0396, a compound structurally similar to mibefradil but more selective for T-type Ca2+ channels, but not by the specific L-type Ca2+ channel blocker nicardipine. Mibefradil did not show such hypoglycemic effects in heterozygous animals. In addition, triglycerides, basal insulin and food intake were significantly decreased by mibefradil treatment in the db/db mice but not in the controls. Western blot analysis, immunohistochemistry and immunofluorescence staining showed a significantly increased expression of T-type Ca2+ channel α-subunits Cav3.1 and Cav3.2 in liver and brain tissues from db/db mice compared to those from heterozygous animals. CONCLUSIONS: Collectively, these results suggest that T-type Ca2+ channels are potential therapeutic targets for antidiabetic drugs.

  14. Non-invasive blood glucose detection system based on conservation of energy method.

    Science.gov (United States)

    Zhang, Yang; Zhu, Jian-Ming; Liang, Yong-Bo; Chen, Hong-Bo; Yin, Shi-Min; Chen, Zhen-Cheng

    2017-02-01

    The most common method used for minimizing the occurrence of diabetes complications is frequent glucose testing to adjust the insulin dose. However, using blood glucose (BG) meters presents a risk of infection. It is of great importance to develop non-invasive BG detection techniques. To realize high-accuracy, low-cost and continuous glucose monitoring, we have developed a non-invasive BG detection system using a mixed signal processor 430 (MSP430) microcontroller. This method is based on the combination of the conservation-of-energy method with a sensor integration module, which collects physiological parameters, such as the blood oxygen saturation (SPO2), blood flow velocity and heart rate. New methods to detect the basal metabolic rate (BMR) and BV are proposed, which combine the human body heat balance and characteristic signals of photoplethysmography as well dual elastic chambers theory. Four hundred clinical trials on real-time non-invasive BG monitoring under suitable experiment conditions were performed on different individuals, including diabetic patients, senior citizens and healthy adults. A multisensory information fusion model was applied to process these samples. The algorithm (we defined it as DCBPN algorithm) applied in the model combines a decision tree and back propagation neural network, which classifies the physiological and environmental parameters into three categories, and then establishes a corresponding prediction model for the three categories. The DCBPN algorithm provides an accuracy of 88.53% in predicting the BG of new samples. Thus, this system demonstrates a great potential to reliably detect BG values in a non-invasive setting.

  15. Correlation between macrosomia body indices and maternal fasting blood glucose.

    Science.gov (United States)

    Song, Y; Zhang, S; Song, W

    2014-05-01

    To explore the significance of neonatal body indices in identifying pathological macrosomia, we implemented a retrospective study of 254 neonates, including: 100 macrosomia of diabetic pregnancies, 77 macrosomia of healthy pregnancies and 77 normal neonates of healthy pregnancies, using their birth weight, body length, head circumference and chest circumference, to calculate neonatal body indices, multiple regression analysis of the correlation between newborn body indices and maternal fasting blood glucose. The Quetelet Index and Kaup Index of diabetic macrosomia is higher than that of non-diabetic macrosomia; HC:CC (ratio between head circumference and chest circumference) is reversed (p macrosomia.

  16. Qualitative study of telemonitoring of blood glucose and blood pressure in type 2 diabetes.

    Science.gov (United States)

    Hanley, Janet; Fairbrother, Peter; McCloughan, Lucy; Pagliari, Claudia; Paterson, Mary; Pinnock, Hilary; Sheikh, Aziz; Wild, Sarah; McKinstry, Brian

    2015-12-23

    To explore the experiences of patients and professionals taking part in a randomised controlled trial (RCT) of blood glucose, blood pressure (BP) and weight telemonitoring in type 2 diabetes supported by primary care, and identify factors facilitating or hindering the effectiveness of the intervention and those likely to influence its potential translation to routine practice. Qualitative study adopting an interpretive descriptive approach. 23 patients, 6 nurses and 4 doctors who were participating in a RCT of blood glucose and BP telemonitoring. A maximum variation sample of patients from within the trial based on age, sex and deprivation status of the practice was sought. 12 primary care practices in Scotland and England. Data were collected via recorded semistructured interviews. Analysis was inductive with themes presented within an overarching thematic framework. Multiple strategies were employed to ensure that the analysis was credible and trustworthy. Telemonitoring of blood glucose, BP and weight by people with type 2 diabetes was feasible. The data generated by telemonitoring supported self-care decisions and medical treatment decisions. Motivation to self-manage diet was increased by telemonitoring of blood glucose, and the 'benign policing' aspect of telemonitoring was considered by patients to be important. The convenience of home monitoring was very acceptable to patients although professionals had some concerns about telemonitoring increasing workload and costs. Telemonitoring of blood glucose, BP and weight in primary care is a promising way of improving diabetes management which would be highly acceptable to the type of patients who volunteered for this study. ISRCTN71674628; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. [Reliability of blood pressure measurements; comparison of an electronic meter and a mercury manometer in family practice].

    Science.gov (United States)

    van Doorn, B A; van der Does, E; Lubsen, J; Rijsterborgh, H

    1990-08-25

    The Riva-Rocci indirect method of measuring the blood pressure carries a number of sources of error. A report is presented of a study of the serviceability of an electronic blood pressure meter as compared with the conventional mercury manometer. Seventy-six paired measurements were carried out in patients selected at random using an electronic blood pressure meter and a mercury manometer meeting all Health Council requirements. The systematic error and the incidental error in both measuring procedures were compared. The differences found were so slight as to be negligible in practice. It is concluded that the electronic blood pressure meter in practice constitutes an acceptable substitute for the conventional mercury manometer.

  18. High Blood Glucose: What It Means and How To Treat It

    Science.gov (United States)

    ... leave this field empty High Blood Glucose: What It Means and How To Treat It What is high blood glucose? People who do ... glucose, also called 'hyperglycemia', is considered "high" when it is 160 mg/dl or above your individual ...

  19. Capillary bedside blood glucose measurement in neonates: missing a diagnosis of galactosemia.

    Science.gov (United States)

    Özbek, Mehmet Nuri; Öcal, Murat; Tanrıverdi, Sibel; Baysal, Birsen; Deniz, Ahmet; Öncel, Kahraman; Demirbilek, Hüseyin

    2015-03-01

    A number of factors may lead to inaccuracy in measurement of capillary blood glucose with a glucometer. Measurement of other carbohydrate molecules such as galactose and fructose along with glucose can potentially be a cause of error. We report a newborn patient who was referred to our hospital with conjugated bilirubinemia, hepatomegaly and high capillary blood glucose levels measured with a glucometer. Simultaneous biochemical measurements revealed normal blood glucose levels. Further investigation led to a diagnosis of classical galactosemia. Capillary blood glucose level measured with glucometer also dropped to normal values following cessation of breastfeeding and initiation of feeding with a lactose-free formula.

  20. Mango Supplementation Improves Blood Glucose in Obese Individuals

    Science.gov (United States)

    Evans, Shirley F; Meister, Maureen; Mahmood, Maryam; Eldoumi, Heba; Peterson, Sandra; Perkins-Veazie, Penelope; Clarke, Stephen L; Payton, Mark; Smith, Brenda J; Lucas, Edralin A

    2014-01-01

    This pilot study examined the effects of freeze-dried mango (Mangifera indica L.) supplementation on anthropometrics, body composition, and biochemical parameters in obese individuals. Twenty obese adults (11 males and 9 females) ages 20- to 50-years old, received 10 g/day of ground freeze-dried mango pulp for 12 weeks. Anthropometrics, biochemical parameters, and body composition were assessed at baseline and final visits of the study. After 12 weeks, mango supplementation significantly reduced blood glucose in both male (−4.45 mg/dL, P = 0.018) and female (−3.56 mg/dL, P = 0.003) participants. In addition, hip circumference was reduced in male (−3.3 cm, P = 0.048) but not in female participants. However, there were no significant changes in body weight or composition in either gender. Our findings indicate that regular consumption of freeze-dried mango by obese individuals does not negatively impact body weight but provides a positive effect on fasting blood glucose. PMID:25210462

  1. Comparisons of home blood glucose testing and glycated protein measurements.

    Science.gov (United States)

    Lee, P D; Sherman, L D; O'Day, M R; Rognerud, C L; Ou, C N

    1992-04-01

    We examined the relationships between 4 glycated protein assays and home blood glucose monitoring (HBGM) in 26 children with poorly-controlled insulin-dependent diabetes mellitus (IDDM) during a period of improved management. At 2 week intervals for 6 visits (12 weeks in total), HBGM records were collected and a blood sample was obtained for measurement of glycated proteins and glucose. Assays included glycated hemoglobin (GHb) and glycated serum proteins (GP) by boronate affinity chromatography, hemoglobin A1C by PolyCAT A high performance liquid chromatography (HAC) and fructosamine (FA). All 4 glycated protein levels declined significantly over the 12 week period. Significant correlations between the glycated proteins and HBGM were observed over 2 week intervals. None of the 4 assays were affected by the glucose level in the sample. Changes in mean HBGM readings over 2 week intervals were correlated with both FA and GP with wide prediction intervals. Over cumulative 2 week intervals, which may more accurately reflect longitudinal trends, all 4 glycated proteins were correlated with mean HBGM readings. At each cumulative interval, GHb and GP showed the largest variation with MBG, while FA showed the least variation with MBG. Our data indicate that of the 4 assays tested, FA has limited clinical values as compared to other glycated protein assays, whereas assays based on boronate affinity chromatography (GHb and GP) provide the most useful clinical indicators of short-term changes in glycemic control. The clinical utility of a new HPLC method for determination of glycated hemoglobins is also demonstrated.

  2. Community pharmacy-based intervention to improve self-monitoring of blood glucose in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Müller U

    2006-12-01

    Full Text Available Self-monitoring of blood glucose (SMBG is clearly correlated with increased life expectancy and quality of life in type 2 diabetic patients. Objective: The objective of our study was to record and assess the errors patients make in preparing, performing, and processing self-monitoring of blood glucose (SMBG. Furthermore, the study aimed to determine to what extent a single standardized SMBG instruction session in a community pharmacy might reduce the number of patients making errors or the number of errors per patient. Methods: Between May and October 2005, SMBG of 462 randomly selected patients with type 2 diabetes was monitored in 32 pharmacies specialized in diabetes care. The patients performed blood glucose self-tests using their own blood glucose meters. Self-testing was monitored using a standardized documentation sheet on which any error made during the performance of the test was recorded. If necessary, patients were instructed in the accurate operation of their meter and the use of the necessary equipment. Additionally, patients obtained written instructions. Six weeks later, assessment of the quality of patient’s SMBG was repeated.Results: During the first observation, 383 patients (83% made at least one mistake performing SMBG. By the time of the second observation, this frequency had fallen to 189 (41% (p<0.001. The average number of mistakes fell from 3.1 to 0.8 per patient. Mistakes that may potentially have led to inaccurate readings were initially recorded for 283 (61% and at study end for 110 (24% patients (p<0.001. Conclusion: It is important to periodically instruct type 2 diabetic patients in the proper SMBG technique in order to ensure accurate measurements. In this study it was shown that community pharmacies specialized in diabetes care can provide this service effectively.

  3. Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy

    Science.gov (United States)

    Jiang, Jingying; Zhang, Lingling; Gong, Qiliang; Xu, Kexin

    2011-03-01

    There is a growing body of studies suggesting that NIR spectroscopy is feasible to be used to non-invasive blood glucose sensing. However, previous results reported that blood components are very complicated and in which glucose concentration is relatively low. This feature limited the practical application of NIR spectroscopy to in vivo blood glucose detection. This talk aims to elucidate how the cholesterol influences blood glucose sensing. Spectroscopic measurements show that cholesterol appears the similar absorbance peaks to those of glucose within NIR range. Furthermore, PLS modelling results demonstrate that the measurement concentrations of glucose are on the high side while containing cholesterol. For example, when the cholesterol concentration is 200mg/dl, the measurement result of glucose with near-infrared spectroscopy will increase 7.961882mg/dl comparing to cholesterol-free glucose solution. Therefore, it is necessary to take steps to reduce cholesterol's effects.

  4. COMPARATIVE STUDY OF GLUCOMETER AND LABORATORY GLUCOSE OXIDASE METHOD FOR THE ESTIMATION OF BLOOD GLUCOSE LEVELS IN NEONATES

    Directory of Open Access Journals (Sweden)

    Harish

    2015-02-01

    Full Text Available INTRODUCTION : Hypoglycemia is one of the most common metabolic problems encountered in neonates. Hypoglycemia in neonates can be symptomatic and asymptomatic. Hypoglycemia is known to be associated with brain dysfunction and neuromotor developmental retardation. The gl ucose oxidase method used in the laboratory for determining the blood glucose concentration is precise and specific for glucose. As it is usually performed in the main laboratory, the results are not available quickly enough for timely appropriate manageme nt. The glucometers are often used for blood glucose estimation in NICU. Many studies have shown that their results co - relate well with the laboratory measured glucose levels in the normoglycemic and hyperglycemic range but are not satisfactory in the lowe r range. OBJECTIVES: This is a prospective study done to determine the efficacy of glucometer in estimation of blood glucose levels in neonates in comparison with the laboratory values. METHOD S : 250 neonates admitted in NICU, KIMS hospital, Bangalore with varied symptomatology were enrolled in this study. Blood glucose estimation was done by glucometer and laboratory method using the same venous sample at the time of admission. For the last 50 cases glucometer estimation of capillary blood was also done. St atistical analysis was done by using Pearson correlation. Hypoglycemia was defined as blood glucose level 45mg%[0.756] and when the value is <45mg%, there is just a moderate correlation[0.417] . Though the pick - up rate of hypoglycemia by venous blood glucometer [28%] was slightly better compared to the capillary blood glucometer value [22%] , the overa ll pick - up rate of hypoglycemia by glucometer is very low compared to the laboratory method [56%]. CONCLUSION : The glucometer as a sole measuring device to screen neonatal hypoglycemia is not satisfactory and confirmation with the laboratory measurements o f plasma glucose is still of up most importance.

  5. Using a Personal Glucose Meter and Alkaline Phosphatase for Point-of-Care Quantification of Galactose-1-Phosphate Uridyltransferase in Clinical Galactosemia Diagnosis.

    Science.gov (United States)

    Zhang, Jingjing; Xiang, Yu; Novak, Donna E; Hoganson, George E; Zhu, Junjie; Lu, Yi

    2015-10-01

    The personal glucose meter (PGM) was recently shown to be a general meter to detect many targets. Most studies, however, focus on transforming either target binding or enzymatic activity that cleaves an artificial substrate into the production of glucose. More importantly, almost all reports exhibit their methods by using artificial samples, such as buffers or serum samples spiked with the targets. To expand the technology to even broader targets and to validate its potential in authentic, more complex clinical samples, we herein report expansion of the PGM method by using alkaline phosphatase (ALP) that links the enzymatic activity of galactose-1-phosphate uridyltransferase to the production of glucose, which allows point-of-care galactosemia diagnosis in authentic human clinical samples. Given the presence of ALP in numerous enzymatic assays for clinical diagnostics, the methods demonstrated herein advance the field closer to point-of-care detection of a wide range of targets in real clinical samples.

  6. Elevated 1-h post-challenge plasma glucose levels in subjects with normal glucose tolerance or impaired glucose tolerance are associated with whole blood viscosity.

    Science.gov (United States)

    Marini, Maria Adelaide; Fiorentino, Teresa Vanessa; Andreozzi, Francesco; Mannino, Gaia Chiara; Perticone, Maria; Sciacqua, Angela; Perticone, Francesco; Sesti, Giorgio

    2017-08-01

    It has been suggested that glucose levels ≥155 mg/dl at 1-h during an oral glucose tolerance test (OGTT) may predict development of type 2 diabetes and cardiovascular events among adults with normal glucose tolerance (NGT 1 h-high). Studies showed a link between increased blood viscosity and type 2 diabetes. However, whether blood viscosity is associated with dysglycemic conditions such as NGT 1 h-high, impaired glucose tolerance (IGT) or impaired fasting glucose (IFG) is unsettled. 1723 non-diabetic adults underwent biochemical evaluation and OGTT. A validated formula based on hematocrit and total plasma proteins was employed to estimate whole blood viscosity. Subjects were categorized into NGT with 1 h glucose h-low), NGT-1 h-high, IFG and/or IGT. Hematocrit and blood viscosity values appeared significantly higher in individuals with NGT 1 h-high, IFG and/or IGT as compared to NGT 1 h-low subjects. Blood viscosity was significantly correlated with age, waist circumference, blood pressure, HbA1c, fasting, 1- and 2-h post-challenge insulin levels, total cholesterol and low-density lipoprotein, triglycerides, fibrinogen, white blood cell, and inversely correlated with high-density lipoprotein and insulin sensitivity. Of the four glycemic parameters, 1-h post-challenge glucose showed the strongest correlation with blood viscosity (β = 0.158, P h post-challenge plasma glucose. They also suggest that a subgroup of NGT individuals with 1-h post-challenge plasma >155 mg/dl have increased blood viscosity comparable to that observed in subjects with IFG and/or IGT.

  7. Blood Glucose Variability and Outcomes in Critically Ill Children

    Science.gov (United States)

    Naranje, Kirti Mahadeorao; Poddar, Banani; Bhriguvanshi, Arpita; Lal, Richa; Azim, Afzal; Singh, Ratender K.; Gurjar, Mohan; Baronia, Arvind K.

    2017-01-01

    Objectives: To find the incidence of hyperglycemia (blood glucose [BG] ≥150 mg/dl), hypoglycemia (BG ≤60 mg/dl), and variability (presence of hypoglycemia and hyperglycemia) in critically ill children in the 1st week of Intensive Care Unit (ICU) stay and their association with mortality, length of ICU stay, and organ dysfunction. Materials and Methods: The design was a retrospective observational cohort study. Consecutive children ≤18 years of age admitted from March 2003 to April 2012 in a combined adult and pediatric closed ICU. Relevant data were collected from chart review and hospital database. Results: Out of 258 patients included, isolated hyperglycemia was seen in 139 (53.9%) and was unrelated to mortality and morbidity. Isolated variability in BG was noted in 76 (29.5%) patients and hypoglycemia was seen in 9 (3.5%) patients. BG variability was independently associated with multiorgan dysfunction syndrome on multivariate analysis (adjusted odds ratio [OR]: 7.1; 95% confidence interval [CI]: 1.6–31.1). Those with BG variability had longer ICU stay (11 days vs. 4 days, on log-rank test, P = 0.001). Insulin use was associated with the occurrence of variability (adjusted OR: 3.6; 95% CI: 1.8–7.0). Conclusion: Glucose disorders were frequently observed in critically ill children. BG variability was associated with multiorgan dysfunction and increased ICU stay.

  8. Effects of chronic caffeine administration on blood glucose levels and on glucose tolerance in healthy and diabetic rats.

    Science.gov (United States)

    Urzúa, Z; Trujillo, X; Huerta, M; Trujillo-Hernández, B; Ríos-Silva, M; Onetti, C; Ortiz-Mesina, M; Sánchez-Pastor, E

    2012-01-01

    To analyse the effect of chronic caffeine use on risk reduction and prognosis of diabetes mellitus. In this 60-day study, five groups of 11 healthy male Wistar rats were selected to receive one of four doses (37.5, 56.2, 75.0 or 93.0 mg/kg per day) of caffeine orally or no caffeine (control). The effect of caffeine on glycaemia and glucose tolerance was evaluated. After 15 days, each group was treated with 60 mg/kg of streptozotocine to induce diabetes mellitus, and glycaemia and glucose tolerance were assessed for a further 45 days. In nondiabetic rats, caffeine had no effect on blood glucose. Compared with controls, the fasting blood glucose levels declined significantly in two caffeine-treated groups (93.0 mg/kg per day and 56.2 mg/kg per day) during the first 15 days following diabetes induction. Glucose tolerance was significantly improved 120 min after glucose loading in all caffeine-treated groups. The mean ± SE half-maximal effective concentration of caffeine was 35.79 ± 2.44 mg/dl. Blood glucose levels decreased, and glucose tolerance improved, in diabetic rats administered increasing doses of caffeine.

  9. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Vahidi, O; Kwok, K E; Gopaluni, R B

    2016-01-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main...... drawback of the former model was its restriction on the route of glucose entrance to the body which was limited to the intravenous glucose injection. To handle the oral glucose intake, we have added a model of glucose absorption in the gastrointestinal tract to the former model to address the resultant...... variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data...

  10. The Effects of Blood Glucose Levels on Cognitive Performance: A Review of the Literature

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel

    2007-01-01

    The purpose of this review paper is to discuss the research literature on the effects of blood glucose levels on executive and non-executive functions in humans. The review begins with a brief description of blood glucose, how it has been studied, previous syntheses of prior studies, and basic results regarding the role of blood glucose on cognitive functioning. The following sections describe work that investigated the effect of blood glucose on both non-executive and executive functions (e.g., sensory processing, psychomotor functioning, attention, vigilance, memory, language and communication, judgement and decision-making, and complex task performance). Within each section, summaries of the findings and challenges to the literature are included. Measurement conversions of blood glucose levels, blood glucose values, and associated symptoms are depicted. References to the types of tests used to investigate blood glucose and cognitive performance are provided. For more detailed descriptions of references within (and in addition to) this paper, an annotated bibliography is also provided. Several moderator variables including individual differences and contextual variables related to the effects of blood glucose levels on performance (e.g., age, gender, time of day, familiarity with the task and symptom awareness, expectancy effects, dose dependent effects, time dependent effects, task specific effects, rising and falling blood glucose levels, and speed and/or accuracy trade-offs) are addressed later in the paper. Some suggestions for future experimental methodologies are also made.

  11. An artificial pancreas provided a novel model of blood glucose level variability in beagles.

    Science.gov (United States)

    Munekage, Masaya; Yatabe, Tomoaki; Kitagawa, Hiroyuki; Takezaki, Yuka; Tamura, Takahiko; Namikawa, Tsutomu; Hanazaki, Kazuhiro

    2015-12-01

    Although the effects on prognosis of blood glucose level variability have gained increasing attention, it is unclear whether blood glucose level variability itself or the manifestation of pathological conditions that worsen prognosis. Then, previous reports have not been published on variability models of perioperative blood glucose levels. The aim of this study is to establish a novel variability model of blood glucose concentration using an artificial pancreas. We maintained six healthy, male beagles. After anesthesia induction, a 20-G venous catheter was inserted in the right femoral vein and an artificial pancreas (STG-22, Nikkiso Co. Ltd., Tokyo, Japan) was connected for continuous blood glucose monitoring and glucose management. After achieving muscle relaxation, total pancreatectomy was performed. After 1 h of stabilization, automatic blood glucose control was initiated using the artificial pancreas. Blood glucose level varied for 8 h, alternating between the target blood glucose values of 170 and 70 mg/dL. Eight hours later, the experiment was concluded. Total pancreatectomy was performed for 62 ± 13 min. Blood glucose swings were achieved 9.8 ± 2.3 times. The average blood glucose level was 128.1 ± 5.1 mg/dL with an SD of 44.6 ± 3.9 mg/dL. The potassium levels after stabilization and at the end of the experiment were 3.5 ± 0.3 and 3.1 ± 0.5 mmol/L, respectively. In conclusion, the results of the present study demonstrated that an artificial pancreas contributed to the establishment of a novel variability model of blood glucose levels in beagles.

  12. Evaluation of a combined blood glucose monitoring and gaming system (Didget®) for motivation in children, adolescents, and young adults with type 1 diabetes.

    Science.gov (United States)

    Klingensmith, Georgeanna J; Aisenberg, Javier; Kaufman, Francine; Halvorson, Mary; Cruz, Eric; Riordan, Mary Ellen; Varma, Chandrasekhar; Pardo, Scott; Viggiani, Maria T; Wallace, Jane F; Schachner, Holly C; Bailey, Timothy

    2013-08-01

    The purpose of this study was to assess the performance and acceptability of a blood glucose meter coupled with a gaming system for children, adolescents, and young adults with type 1 diabetes. During an in-clinic visit, duplicate blood samples were tested by subjects (N = 147; aged 5-24 yr) and health care providers (HCPs) to evaluate the accuracy and precision of the Didget® system. Subjects' meter results were compared against Yellow Springs Instruments (YSI) reference results and HCP results using least squares regression and error grid analyses. Precision was measured by average within-subject and within-HCP coefficient of variation (CV). During the home-use component of this study, subjects (n = 58) tested their blood glucose at least two to three times daily for 3-5 d to evaluate routine use of the system. Subjects' meter results showed significant correlations with both YSI (r(2) = 0.94; p motivating, and helpful for building good blood glucose monitoring habits. Most HCPs agreed that the system fulfilled a need in diabetes management. In conclusion, the Didget® system was precise and clinically accurate in the hands of children, adolescents, and young adults with type 1 diabetes.

  13. Application of transcutaneous diffuse reflectance spectroscopy in the measurement of blood glucose concentration

    Institute of Scientific and Technical Information of China (English)

    Wenliang Chen(陈文亮); Rong Liu(刘蓉); Houxin Cui(崔厚欣); Kexin Xu(徐可欣); Lina Lü(吕丽娜)

    2004-01-01

    In this paper, the propagation characteristics of near-infrared (NIR) light in the palm tissue are analyzed,and the principle and feasibility of using transcutaneous diffuse reflectance spectroscopy for non-invasive blood glucose detection are presented. An optical probe suitable for measuring the diffuse reflectance spectrum of human palm and a non-invasive blood glucose detection system using NIR spectroscopy are designed. Based on this system, oral glucose tolerance tests are performed to measure the blood glucose concentrations of two young healthy volunteers. The partial least square calibration model is then constructed by all individual experimental data. The final result shows that correlation coefficients of the two experiments between the predicted blood glucose concentrations and the reference blood glucose concentrations are 0.9870 and 0.9854, respectively. The root mean square errors of prediction of full cross validation are 0.54 and 0.52 mmol/1, respectively.

  14. Blood glucose testing in the hospital: error sources and risk management.

    Science.gov (United States)

    Nichols, James H

    2011-01-01

    Glucose testing in the hospital with point-of-care devices presents multiple opportunities for error. Any device can fail under the right conditions. For glucose monitoring in the hospital, with thousands of operators, hundreds of devices, and dozens of locations involved, there is ample opportunity for errors that can impact the quality of test results. Errors can occur in any phase of the testing process: preanalytic, analytic, or postanalytic. Common sources of meter error include patient or methodology interferences, operator mistakes, environmental exposure, and device malfunction. Early models of glucose meters had few internal checks or capability to warn the operator of meter problems. The latest generation of glucose monitors has a number of internal checks and controls engineered into the testing process to prevent serious errors or warn the operator by suppressing test results. Some of these control processes are built into the software and data management system of the meters, others require the hospital to do something, such as regularly clean the meter or analyze control samples of known glucose concentration, to verify meter performance. Hospitals need to be aware of the potential for errors by understanding weaknesses in the testing process that could lead to erroneous results and take steps to prevent errors from occurring or to minimize the harm to patients when errors do occur. The reliability of a glucose result will depend on the balance of internal control features available from manufacturers in conjunction with the liquid control analysis and other control processes (operator training, device validation, and maintenance) utilized by the hospitals.

  15. Effects of self-monitoring of blood glucose on diabetes control in a ...

    African Journals Online (AJOL)

    found no definite evidence that home blood glucose monitoring improved blood ... from Denmark). The data collection was approved by the UMgungundlovu Health ..... in children and adults during 1980-2013: a systematic analysis for the.

  16. A Simple Flow Cytometric Method to Measure Glucose Uptake and Glucose Transporter Expression for Monocyte Subpopulations in Whole Blood.

    Science.gov (United States)

    Palmer, Clovis S; Anzinger, Joshua J; Butterfield, Tiffany R; McCune, Joseph M; Crowe, Suzanne M

    2016-08-12

    Monocytes are innate immune cells that can be activated by pathogens and inflammation associated with certain chronic inflammatory diseases. Activation of monocytes induces effector functions and a concomitant shift from oxidative to glycolytic metabolism that is accompanied by increased glucose transporter expression. This increased glycolytic metabolism is also observed for trained immunity of monocytes, a form of innate immunological memory. Although in vitro protocols examining glucose transporter expression and glucose uptake by monocytes have been described, none have been examined by multi-parametric flow cytometry in whole blood. We describe a multi-parametric flow cytometric protocol for the measurement of fluorescent glucose analog 2-NBDG uptake in whole blood by total monocytes and the classical (CD14(++)CD16(-)), intermediate (CD14(++)CD16(+)) and non-classical (CD14(+)CD16(++)) monocyte subpopulations. This method can be used to examine glucose transporter expression and glucose uptake for total monocytes and monocyte subpopulations during homeostasis and inflammatory disease, and can be easily modified to examine glucose uptake for other leukocytes and leukocyte subpopulations within blood.

  17. Blood glucose control using an artificial pancreas reduces the workload of ICU nurses.

    Science.gov (United States)

    Mibu, Kiyo; Yatabe, Tomoaki; Hanazaki, Kazuhiro

    2012-03-01

    Blood glucose management is one of the important therapies in the intensive care unit (ICU). However, blood glucose management using the sliding-scale method increases the workload of ICU nurses. An artificial pancreas, STG-22, has been developed to continuously monitor blood glucose levels and to maintain them at appropriate levels. In this study, we examined the hypothesis that compared to conventional methods, blood glucose management using the STG-22 reduces the workload of ICU nurses and has a positive impact on awareness regarding the management of blood glucose. This study included 45 patients who underwent elective surgery and were treated at the ICU postoperatively. The patients were separated into the following two groups: (1) blood glucose was maintained using the STG-22 (AP group) and (2) blood glucose was maintained using the sliding-scale method (SS group). In addition, a questionnaire was developed for an awareness survey of ICU nurses (N = 20). The frequency of blood sampling and number of double checks were significantly lower in the AP group (1.3 ± 1.4 vs. 8.9 ± 8.1 times/admission, P blood glucose.

  18. Postprandial blood glucose level in maintenance hemodialysis patients predicts post-transplant-diabetes-mellitus.

    Science.gov (United States)

    Haider, D G; Mittermayer, F; Friedl, A; Batrice, A; Auinger, M; Wolzt, M; Hörl, W H

    2010-03-01

    Post-transplant-diabetes-mellitus (PTDM) is a frequent complication after kidney transplantation. One-hundred-and-seven patients with kidney transplantation were screened for the occurrence of PTDM. Of these, full data sets from 49 subjects were available with documented glucose concentrations during maintenance hemodialysis (MHD) and regular clinical follow-up of 7-34 months. For assessment of glucose metabolism the response to a standard meal during MHD was used in normoglycemic patients based on fasting blood glucose. Abnormal postprandial blood glucose concentration was defined as >140 mg/dl 2 h after food intake.Twelve end stage renal disease patients had abnormal postprandial blood glucose on MHD. All 12 subjects but also four MHD patients with normal postprandial and fasting blood glucose values developed PTDM. Multivariate Cox-regression analysis revealed that abnormal postprandial blood glucose is a strong predictor for PTDM (Hazard ratio: 42.3 (IQR: 7.9-227.2); p<0.001). Fasting blood glucose (94 vs. 100 mg/dl) was not different between MHD patients who did (n=16) or did not (n=33) develop PTDM.This study suggests that measurement of postprandial blood glucose during MHD identifies patients who develop PTDM after kidney transplantation. It should be used for screening of patients at risk.

  19. The Impact of opium consumption on blood glucose, serum lipids and blood pressure, and related mechanisms

    Directory of Open Access Journals (Sweden)

    Hamid Najafipour

    2016-10-01

    Full Text Available AbstractAim: Substance abuse has become a universal crisisin our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (77 articles. Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms, but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption.

  20. Lower fasting blood glucose in neurofibromatosis type 1

    Science.gov (United States)

    Martins, Aline Stangherlin; Jansen, Ann Kristine; Rodrigues, Luiz Oswaldo Carneiro; Matos, Camila Maria; Souza, Marcio Leandro Ribeiro; de Souza, Juliana Ferreira; Diniz, Maria de Fátima Haueisen Sander; Barreto, Sandhi Maria; Diniz, Leonardo Mauricio; de Rezende, Nilton Alves; Riccardi, Vincent Michael

    2015-01-01

    Studies indicate a lower occurrence of diabetes mellitus (DM) in patients with neurofibromatosis type 1 (NF1). Fasting blood glucose (FBG) level is the main criterion used to diagnose DM and glucose intolerance. Therefore, this study compared FBG level between adults with NF1 and non-NF1 controls. We selected clinical records of 57 out of 701 individuals attending the Neurofibromatosis Outpatient Reference Center of the Clinics Hospital of the Federal University of Minas Gerais in Brazil. The selected patients with NF1 were matched to non-NF1 controls selected from the Brazilian Longitudinal Study of Adult Health according to sex, age (range, 35–74 years) and BMI at a ratio of 1:3. In both groups, individuals with DM were excluded. Median FBG level in the NF1 group (86 mg/dl (range, 56–127 mg/dl)) was lower than that in the non-NF1 control group (102 mg/dl (range, 85–146 mg/dl)) (P<0.001). Prevalence of FBG level ≥100 mg/dl in the NF1 group (16%) was lower than that in the non-NF1 control group (63%) (P<0.05). The chance of a high FBG level was 89% lower in the NF1 group (odds ratio, 0.112; 95% CI, 0.067–0.188) (P<0.05). In conclusion, adults with NF1 showed a lower FBG level and a lower prevalence of high FBG level compared with non-NF1 controls. PMID:26631381

  1. Examination of liver and muscle glycogen and blood glucose levels ...

    African Journals Online (AJOL)

    ... energy requirement is high and start to decrease after May when reproduction starts. In the summer, it was determined that glycogen and glucose reserves were at ... Glycogen and glucose reserves generally showed parallel changes with ...

  2. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob L.; Kurzban, Robert

    2016-01-01

    The academic and public interest in blood glucose and its relationship to decision making has been increasing over the last decade. To investigate and evaluate competing theories about this relationship, we conducted a psychometric meta-analysis on the effect of blood glucose on decision making. We...... identified 42 studies relating to 4 dimensions of decision making: willingness to pay, willingness to work, time discounting, and decision style. We did not find a uniform influence of blood glucose on decision making. Instead, we found that low levels of blood glucose increase the willingness to pay...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money...

  3. Fasting blood glucose--a missing variable for GFR-estimation in type 1 diabetes?

    Directory of Open Access Journals (Sweden)

    Petter Bjornstad

    Full Text Available Estimation of glomerular filtration rate (eGFR is one of the current clinical methods for identifying risk for diabetic nephropathy in subjects with type 1 diabetes (T1D. Hyperglycemia is known to influence GFR in T1D and variability in blood glucose at the time of eGFR measurement could introduce bias in eGFR. We hypothesized that simultaneously measured blood glucose would influence eGFR in adults with T1D.Longitudinal multivariable mixed-models were employed to investigate the relationships between blood glucose and eGFR by CKD-EPI eGFRCYSTATIN C over 6-years in the Coronary Artery Calcification in Type 1 diabetes (CACTI study. All subjects with T1D and complete data including blood glucose and cystatin C for at least one of the three visits (n = 616, 554, and 521, respectively were included in the longitudinal analyses.In mixed-models adjusting for sex, HbA1c, ACEi/ARB, protein and sodium intake positive associations were observed between simultaneous blood glucose and eGFRCYSTATIN C (β±SE:0.14±0.04 per 10 mg/dL of blood glucose, p<0.0001, and hyperfiltration as a dichotomous outcome (OR: 1.04, 95% CI: 1.01-1.07 per 10 mg/dL of blood glucose, p = 0.02.In our longitudinal data in subjects with T1D, simultaneous blood glucose has an independent positive effect on eGFRCYSTATIN C. The associations between blood glucose and eGFRCYSTATIN C may bias the accurate detection of early diabetic nephropathy, especially in people with longitudinal variability in blood glucose.

  4. Evaluation of the Capillary Blood Glucose Self-monitoring Program

    Science.gov (United States)

    Augusto, Mariana Cristina; Nitsche, Maria José Trevizani; Parada, Cristina Maria Garcia de Lima; Zanetti, Maria Lúcia; Carvalhaes, Maria Antonieta de Barros Leite

    2014-01-01

    OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city. METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288) of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics. RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively. CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved. PMID:25493676

  5. Evaluation of the Capillary Blood Glucose Self-monitoring Program

    Directory of Open Access Journals (Sweden)

    Mariana Cristina Augusto

    2014-10-01

    Full Text Available OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city.METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288 of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics.RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively.CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.

  6. Intraoperative blood glucose levels in neurosurgical patients : an evaluation of two fluid regimens.

    Directory of Open Access Journals (Sweden)

    Swamy M

    2001-10-01

    Full Text Available Based on the evidence that hyperglycaemia aggravates ischaemic cerebral injury, it has been suggested that blood glucose levels be kept within 200 mg/dL during intracranial neurosurgery. Hypoglycaemia, however, can be a serious problem if glucose-containing solutions are avoided during the first four hours, as suggested in some studies. In order to explore the possibility of administering glucose in moderation so that the blood glucose levels are within acceptable limits, but at the same time the risk of hyoglycaemia is eliminated, we compared two intraoperative fluid regimens. Of the 52 neurosurgical patients studied, 32 patients received alternately 500 ml of 5% dextrose in normal saline and Ringer′s lactate (DNS/RL Group and 18 patients received alternately 500 ml of Ringer′s lactate and normal saline (RL/NS Group. Blood glucose concentrations were determined at the end of each unit of fluid, until the patient received 4 units of fluid. In the DNS/RL group, blood glucose values peaked with the administration of each unit of DNS and tended to return towards the baseline with the subsequent RL, but remained higher than the previous control value. In the RL/NS group, there was a progressive increase in blood glucose values throughout the study period, but the increase was not statistically significant. The blood glucose levels were significantly different between the two groups after each unit of fluid except at the end of the fourth unit. Two patients in the RL/NS group had hypoglycaemia. In conclusion, the DNS/RL regimen maintains blood glucose levels within acceptable limits while avoiding the risk of hyperglycaemia. Withholding glucose completely, lowers blood glucose levels, but carries a risk of hypoglycaemia in some patients.

  7. STRING BEAN JUICE DECREASES BLOOD GLUCOSE LEVEL PATIENTS WITH DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Harmayetty Harmayetty

    2017-07-01

    Full Text Available Introduction: Type 2 diabetes mellitus is deficiency of insulin and caused by decreases of insulin receptor or bad quality of insulin. As a result, insulin hormone does not work effectively in blood glucose regulation. String bean juice contains thiamin and fiber may regulate blood glucose level. The aim of this study was to analyze the effect of string bean juice to decrease blood glucose level of patients with type 2 diabetes mellitus. Method: This study employed a quasy-experimental pre-post test control group design and purposive sampling.  The population were all type 2 diabetes mellitus patients in Puskesmas Pacar Keling Surabaya. Sample were 12 patients who met inclusion criteria. The independent variable was string bean juice and dependent variable was blood glucose level. Data were analyzed by using Paired T-test with significance level of α≤ 0.05 and Independent T-test with significant level of α≤0.05. Result: The results showed that string bean juice has an effect on decreasing blood glucose between pre test and post test for blood glucose with independent T-test is p=0.003. Analysis: In conclusion, string bean juice has an effect on blood glucose level in patients with type 2 diabetes mellitus. Discussion: The possible explanation for this findings is string bean juice contains two ingredients: thiamine and fiber. Thiamine helps support insulin receptors and glucose transporter in cells hence GLUT-4 could translocated to the cell membrane brought glucouse enter to the  intracellular compartment, that leads to blood glucouse level well regulated.  Dietary fiber reduces food transit time so slowing the glucose absorption. Therefore blood glucose level will be decreased.

  8. In vivo noninvasive measurement of preprandial and postprandial blood glucose using optical coherence tomography

    Science.gov (United States)

    Zhang, Ying; Zhang, Xiyang; Li, Zhifang; Li, Hui

    2016-10-01

    Blood glucose concentration measurement is essential for the diagnosis and treatment of diabetes. However, conventional glucose measurement methods are invasive and not suitable for real-time monitoring. This study demonstrated a noninvasive blood glucose measurement method using optical coherence tomography to image human lip in vivo. Optical coherence tomography (OCT) is a noninvasive and depth-resolved technique capable of acquiring tissue structure images in real time. Human lip has very thin skin and is full of blood vessels, which is appropriate for noninvasive glucose measurement. To verify the feasibility of OCT for glucose concentration monitoring, two groups of OCT imaging data were obtained from human lips of normal people. In one group, OCT images of lip were acquired from people on an empty stomach. In the other group, the same sites of lip were observed by OCT 2 hours after breakfast. Evident differences were found from two groups of OCT images that correspond to preprandial glucose and 2- hour postprandial glucose, respectively. The relationship between OCT image and blood glucose concentration was investigated. The result indicates that OCT possesses considerable prospects in terms of noninvasive blood glucose measurement.

  9. High glucose impairs superoxide production from isolated blood neutrophils

    DEFF Research Database (Denmark)

    Perner, A; Nielsen, S E; Rask-Madsen, J

    2003-01-01

    Superoxide (O(2)(-)), a key antimicrobial agent in phagocytes, is produced by the activity of NADPH oxidase. High glucose concentrations may, however, impair the production of O(2)(-) through inhibition of glucose-6-phosphate dehydrogenase (G6PD), which catalyzes the formation of NADPH. This stud...... measured the acute effects of high glucose or the G6PD inhibitor dehydroepiandrosterone (DHEA) on the production of O(2)(-) from isolated human neutrophils....

  10. Training to estimate blood glucose and to form associations with initial hunger

    Directory of Open Access Journals (Sweden)

    Bianchi Riccardo

    2006-12-01

    Full Text Available Abstract Background The will to eat is a decision associated with conditioned responses and with unconditioned body sensations that reflect changes in metabolic biomarkers. Here, we investigate whether this decision can be delayed until blood glucose is allowed to fall to low levels, when presumably feeding behavior is mostly unconditioned. Following such an eating pattern might avoid some of the metabolic risk factors that are associated with high glycemia. Results In this 7-week study, patients were trained to estimate their blood glucose at meal times by associating feelings of hunger with glycemic levels determined by standard blood glucose monitors and to eat only when glycemia was Conclusion Subjects could be trained to accurately estimate their blood glucose and to recognize their sensations of initial hunger at low glucose concentrations. These results suggest that it is possible to make a behavioral distinction between unconditioned and conditioned hunger, and to achieve a cognitive will to eat by training.

  11. Application of optical coherence tomography for noninvasive blood glucose monitoring during hyperglycemia

    Science.gov (United States)

    Larin, Kirill V.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2003-10-01

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from Diabetes Mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for chemical analysis. Recently we proposed to use optical coherence tomography (OCT) for continuous noninvasive blood glucose sensing through skin. In this paper we tested the OCT technique for noninvasive monitoring of blood glucose concentration in lip tissue of New Zealand rabbits and Yucatan micropigs during glucose clamping experiments. Obtained results show good agreement with results obtained in skin studies, good correlation of changes in the OCT signal slope measured at the depth of 250 to 500 μm with changes in blood glucose concentration, and higher stability of the OCT data points than that obtained from skin.

  12. Control of Blood Glucose for People with Type 1 Diabetes: an in Vivo Study

    DEFF Research Database (Denmark)

    2012-01-01

    Since continuous glucose monitoring (CGM) technology and insulin pumps have improved recent years, a strong interest in a closed-loop articial pancreas for people with type 1 diabetes has arisen. Presently, a fully automated controller of blood glucose must face many challenges, such as daily...... variations of patient's physiology and lack of accuracy of glucose sensors. In this paper we design and discuss an algorithm for overnight closed-loop control of blood glucose in people with type 1 diabetes. The algorithm is based on Model Predictive Control (MPC). We use an oset-free autoregressive model...

  13. The Coupling of Cerebral Metabolic Rate of Glucose and Cerebral Blood Flow In Vivo

    DEFF Research Database (Denmark)

    Hasselbalch, Steen; Paulson, Olaf Bjarne

    2012-01-01

    The energy supplied to the brain by metabolic substrate is largely utilized for maintaining synaptic transmission. In this regulation cerebral blood flow and glucose consumption is tightly coupled as well in the resting condition as during activation. Quantification of cerebral blood flow...... not used for aerobic metabolism. Although some of the excess glucose uptake can be explained by lactate production, this phenomenon can still not account for the excess glucose uptake. Thus, more complex metabolic patterns in the brain might be reflected in the excess glucose uptake during activation...

  14. A meta-analysis of blood glucose effects on human decision making.

    Science.gov (United States)

    Orquin, Jacob L; Kurzban, Robert

    2016-05-01

    The academic and public interest in blood glucose and its relationship to decision making has been increasing over the last decade. To investigate and evaluate competing theories about this relationship, we conducted a psychometric meta-analysis on the effect of blood glucose on decision making. We identified 42 studies relating to 4 dimensions of decision making: willingness to pay, willingness to work, time discounting, and decision style. We did not find a uniform influence of blood glucose on decision making. Instead, we found that low levels of blood glucose increase the willingness to pay and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money. Low levels of blood glucose also increase the tendency to make more intuitive rather than deliberate decisions. However, this effect was only observed in situations unrelated to food. We conclude that blood glucose has domain-specific effects, influencing decision making differently depending on the relevance of the situation to acquiring food. (PsycINFO Database Record

  15. The relationships between blood pressure, blood glucose, and bone mineral density in postmenopausal Turkish women

    Science.gov (United States)

    Cakmak, Huseyin Altug; Cakmak, Burcu Dincgez; Yumru, Ayse Ender; Aslan, Serkan; Enhos, Asim; Kalkan, Ali Kemal; Coskun, Ebru Inci; Acikgoz, Abdullah Serdar; Karatas, Suat

    2015-01-01

    Background Hypertension, diabetes mellitus, and osteoporosis are important comorbidities commonly seen in postmenopausal women. The aim of the present study was to investigate the relationships between blood pressure, blood glucose, and bone mineral density (BMD) in postmenopausal Turkish women. Methods In this cross-sectional study, 270 consecutive patients who were admitted to an outpatient clinic with vasomotor symptoms and/or at least 1 year of amenorrhea were included. The patients were categorized into three groups according to their blood pressure and metabolic status as follows: normotensive, hypertensive nondiabetics, and hypertensive diabetics. The T- and z-scores of the proximal femur and lumbar vertebrae were measured with the dual-energy X-ray absorptiometry method to assess the BMD of the study groups. Results Lumbar vertebral T-scores (P<0.001), lumbar vertebral z-scores (P<0.003), and proximal femoral T-scores (P<0.001) were demonstrated to be significantly lower in the hypertensive diabetic group compared to the hypertensive nondiabetic and normotensive groups. Systolic blood pressure was significantly inversely correlated with lumbar vertebral T-scores (r=−0.382; P=0.001), lumbar vertebral z-scores (r=−0.290; P=0.001), and proximal femoral T-scores (r=−0.340; P=0.001). Moreover, diastolic blood pressure was significantly inversely correlated with lumbar vertebral T-scores (r=−0.318; P=0.001), lumbar vertebral z-scores (r=−0.340; P=0.001), and proximal femoral T-scores (r=−0.304; P=0.001). Hypertension (odds ratio [OR]: 2.541, 95% confidence interval [CI]: 1.46–3.48, P=0.003), diabetes mellitus (OR: 2.136, 95% CI: 1.254–3.678, P=0.006), and age (OR: 1.069, 95% CI: 1.007–1.163, P=0.022) were found to be significant independent predictors of osteopenia in a multivariate analysis, after adjusting for other risk parameters. Conclusion The present study is the first to evaluate the relationships between blood pressure, blood glucose

  16. High glucose impairs superoxide production from isolated blood neutrophils

    DEFF Research Database (Denmark)

    Perner, A; Nielsen, S E; Rask-Madsen, J

    2003-01-01

    Superoxide (O(2)(-)), a key antimicrobial agent in phagocytes, is produced by the activity of NADPH oxidase. High glucose concentrations may, however, impair the production of O(2)(-) through inhibition of glucose-6-phosphate dehydrogenase (G6PD), which catalyzes the formation of NADPH. This study...

  17. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben;

    2010-01-01

    The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein and the mesen......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...... and the mesenteric artery and a flow probe around the portal vein to allow assessment of nutrient absorption using Fick's principle. In Exp. 1, six sows (mean LW = 202 ± 28 kg) were fed three diets containing 517, 216 or 225 g/kg DM of starch, respectively. In Exp. 2, six female pigs (mean LW = 59 ± 2 kg) were fed...... three different diets with similar contents of starch (470-506 g/kg DM). The diets in both studies differed regarding amount and solubility of fibre. Blood samples were collected repeatedly 0-10 h after morning feeding. Glucose was measured in whole blood using a glucometer (Accu-Chek®) and in plasma...

  18. Evaluation of blood glucose concentration measurement using photoacoustic spectroscopy in near-infrared region

    Science.gov (United States)

    Namita, Takeshi; Sato, Mitsuki; Kondo, Kengo; Yamakawa, Makoto; Shiina, Tsuyoshi

    2017-03-01

    Diabetes, a typical lifestyle-related disease, is an important disease presenting risks of various complications such as retinopathy, kidney failure, and nervous neuropathy. To treat diabetes, regular and continual self-measurement of blood glucose concentrations is necessary to maintain blood glucose levels and to prevent complications. Usually, daily measurements are taken using invasive methods such as finger-prick blood sampling. Some non-invasive optical techniques have been proposed to reduce pain and infection risk, however, few practical techniques exist today. To realize highly accurate and practical measurement of blood glucose concentrations, the feasibility of a photoacoustic method using near-infrared light was evaluated. A photoacoustic signal from a solution of glucose in water (+0-5 g/dl) or equine blood (+0-400 mg/dl) was measured using a hydrophone (9 mm diameter) at 800-1800 nm wavelengths. We investigated the relation between the glucose solution concentration and the photoacoustic signal intensity or peak position of the received photoacoustic signal (i.e. speed of sound in solutions). Results show that the signal intensity and sound speed of the glucose solution increase with increased glucose concentration for wavelengths at which light absorbance of glucose is high. For quantitative estimation of the glucose solution concentration, the photoacoustic signal intensity ratio between two wavelengths, at which dependence of the signal intensity on glucose concentration is high and low, was calculated. Results confirmed that the signal intensity ratios increase linearly with the glucose concentration. These analyses verified the feasibility of glucose level estimation using photoacoustic measurement in the near-infrared region.

  19. Monitoring of tissue optical properties using OCT: application for blood glucose analysis

    Science.gov (United States)

    Larin, Kirill V.; Eledrisi, Mohsen S.; Ashitkov, Taras V.; Motamedi, Massoud; Esenaliev, Rinat O.

    2002-07-01

    Noninvasive monitoring of tissue optical properties in real time could significantly improve diagnostics and management of various diseases. Recently we proposed to use high- resolution Optical Coherence Tomography (OCT) technique for measurement of tissue scattering coefficient at the depth of up to 1mm. Our pilot studies performed in vitro and in vivo demonstrated that measurement of tissue scattering with this technique can potentially be applied for noninvasive monitoring of blood glucose concentration. High resolution and coherent photon detection of the OCT technique allowed detection of glucose-induced changes in the scattering coefficient. In this paper we report results of in vivo studies performed in dog, New Zealand rabbits, and first human subjects. OCT system with the wavelength of 1300 nm was used in our experiments. OCT signal slope was measured and compared with actual blood glucose concentration. Bolus glucose injections and glucose clamping administrations were used in animal studies. OCT signals were recorded form human subjects during oral glucose tolerance test. Results obtained form both animal and human studies show good correlation between slope of the OCT signals and actual blood glucose concentration measured using standard glucometesr. Sensitivity and accuracy of blood glucose concentrations monitoring with the OCT is discussed. Obtained result suggest that OCT is a promising technique for noninvasive monitoring of tissue analytes including glucose.

  20. 75 FR 2549 - Clinical Accuracy Requirements for Point of Care Blood Glucose Meters; Public Meeting; Request...

    Science.gov (United States)

    2010-01-15

    ... Administration, 10903 New Hampshire Ave., Bldg. 66, rm. 5618, Silver Spring, MD 20993, 301- 796-6152, FAX: 301...) medications and other substances that interfere with the technologies the devices employ. Each session will..., emergency response units, nursing homes, and physicians' offices. Some in the clinical and patient...

  1. Effect of insulin in combination with selenium on blood glucose and GLUT4 expression in skeletal muscle of streptozotocin-induced diabetic rats

    Institute of Scientific and Technical Information of China (English)

    Tian-jiao Xu; Bing-xiang Yuan; Ya-min Zou

    2009-01-01

    Objective To evaluate the effect of low-dose insulin [1 U/(kg · d)] in combination with selenium [180 g/(kg · d)] on general physiological parameters and glucose transporter (GLUT4) level in skeletal mnscle of streptozotocin (STZ)-induced diabetic rats. Methods Diabetic rats were treated with insulin, selenium, and insulin and selenium in combination for four weeks. The level of blood glucose was determined using One Tonch SnreStep Blood Glucose meter and the level of GLUT4 in skeletal muscle was examined by immunobiotting and immnnohistochemistry. Results Our data showed that insulin in combination with selenium could significantly lower blood glucose level and restore the disturbance in GLUT4 level in skeletal muscle. Treatment with insulin was only partially effective in restoring diabetic alterations. Conclusion It can be concluded that there is a synergistic action between insulin and selenium, and that treatment of diabetic rats with combined doses of insulin and selenium is effective in the normalization of blood glucose level and correction of altered GLUT4 distribution in skeletal mnscle of diabetic rats.

  2. Effects of passive static stretching on blood glucose levels in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Park, Seong Hoon

    2015-05-01

    [Purpose] This study determined the effects of passive static stretching on blood glucose levels in patients with type 2 diabetes. [Subjects] Fifteen patients (8 males and 7 females) with type 2 diabetes were recruited and randomly assigned to the control group or passive static stretching group. [Methods] Glycated hemoglobin was measured before and after the 8-week training period. [Results] Glycated hemoglobin levels decreased significantly in the passive static stretching group, and there were significant differences in blood glucose levels between the 2 groups. [Conclusion] Passive static stretching of the skeletal muscles may be an alternative to exercise to help regulate blood glucose levels in diabetes patients.

  3. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Science.gov (United States)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  4. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com [Mathuradas Mohota College of Sciences, Nagpur-440009 (India); Dahikar, P. B., E-mail: pbdahikar@rediffmail.com [Kamla Nehru Mahavidyalaya, Sakkardara Square, Nagpur-440009 (India)

    2014-10-15

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  5. GLP-1 analog raises glucose transport capacity of blood-brain barrier in Alzheimer's disease

    DEFF Research Database (Denmark)

    Gejl, M.; Brock, B.; Egefjord, L.

    2017-01-01

    Objectives: Glucose enters the brain tissue from plasma by facilitated diffusion across the two membranes of the endothelium of the blood-brain barrier (BBB), mediated by the glucose transporter 1 (GLUT1). There is evidence in Alzheimer's disease (AD) of reduction of glucose transport across...... claim that the GLP-1 analog liraglutide may prevent the decline of blood-brain glucose transfer in AD. Methods: In this 26-week test of the hypothesis, we randomized 38 patients with AD to treatment with the GLP-1 analog liraglutide (n = 18) or placebo (n = 20). We determined blood-brain glucose...... transport capacity (Tmax) with [18F]FDG (FDG) (ClinicalTrials.gov NCT01469351). Results: In both groups, the Tmax estimates declined in proportion to the duration of AD. The GLP-1 analog treatment very significantly (P 

  6. Performance Analysis of Fuzzy-PID Controller for Blood Glucose Regulation in Type-1 Diabetic Patients.

    Science.gov (United States)

    Yadav, Jyoti; Rani, Asha; Singh, Vijander

    2016-12-01

    This paper presents Fuzzy-PID (FPID) control scheme for a blood glucose control of type 1 diabetic subjects. A new metaheuristic Cuckoo Search Algorithm (CSA) is utilized to optimize the gains of FPID controller. CSA provides fast convergence and is capable of handling global optimization of continuous nonlinear systems. The proposed controller is an amalgamation of fuzzy logic and optimization which may provide an efficient solution for complex problems like blood glucose control. The task is to maintain normal glucose levels in the shortest possible time with minimum insulin dose. The glucose control is achieved by tuning the PID (Proportional Integral Derivative) and FPID controller with the help of Genetic Algorithm and CSA for comparative analysis. The designed controllers are tested on Bergman minimal model to control the blood glucose level in the facets of parameter uncertainties, meal disturbances and sensor noise. The results reveal that the performance of CSA-FPID controller is superior as compared to other designed controllers.

  7. Influence of blood glucose on the expression of glucose transporter proteins 1 and 3 in the brain of diabetic rats

    Institute of Scientific and Technical Information of China (English)

    HOU Wei-kai; FU Chun-li; ZHANG Wen-wen; CHEN Li; XIAN Yu-xin; ZHANG Li; LAI Hong; HOU Xin-guo; XU Yu-xin; YU Ting; XU Fu-yu; SONG Jun

    2007-01-01

    Background The delivery of glucose from the blood to the brain involves its passage across the endothelial cells of the blood-brain barrier (BBB), which is mediated by the facilitative glucose transporter protein 1 (GLUT1), and then across the neural cell membranes, which is mediated by GLUT3. This study aimed to evaluate the dynamic influence of hyperglycemia on the expression of these GLUTs by measuring their expression in the brain at different blood glucose levels in a rat model of diabetes. This might help to determine the proper blood glucose threshold level in the treatment of diabetic apoplexy.Methods Diabetes mellitus was induced with streptozotocin (STZ) in 30 rats. The rats were randomly divided into 3 groups: diabetic group without blood glucose control (group DM1), diabetic rats treated with low dose insulin (group DM2),and diabetic rats treated with high dose insulin (group DM3). The mRNA and protein levels of GLUT1 and GLUT3 were assayed by reverse transcriptase-polymerase chain reaction (RT-PCR) and immunohistochemistry, respectively.Results Compared with normal control rats, the GLUT1 mRNA was reduced by 46.08%, 29.80%, 19.22% (P<0.01) in DM1, DM2, and DM3 group, respectively; and the GLUT3 mRNA was reduced by 75.00%, 46.75%, and 17.89% (P<0.01)in DM1, DM2, and DM3 group, respectively. The abundance of GLUT1 and GLUT3 proteins had negative correlation with the blood glucose level (P<0.01). The density of microvessels in the brain of diabetic rats did not change significantly compared with normal rats.Conclusions Chronic hyperglycemia downregulates GLUT1 and GLUT3 expression at both mRNA and protein levels in the rat brain, which is not due to the decrease of the density of microvessels. The downregulation of GLUT1 and GLUT3 expression might be the adaptive reaction of the body to prevent excessive glucose entering the cell that may lead to cell damage.

  8. Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs.

    Science.gov (United States)

    Mori, Akihiro; Lee, Peter; Yokoyama, Takeshi; Oda, Hitomi; Saeki, Kaori; Miki, Yohei; Nozawa, Satoshi; Azakami, Daigo; Momota, Yutaka; Makino, Yuki; Matsubara, Takako; Osaka, Motohisa; Ishioka, Katsumi; Arai, Toshiro; Sako, Toshinori

    2011-06-01

    Artificial pancreas technology, involving "closed-loop" controls with real-time blood glucose monitoring, has been increasing in reliability as its potential for clinical use and application grows. One such device, based on this technology, is the STG-22 (Nikkiso Co., Ltd., Tokyo, Japan) artificial pancreas apparatus. In order to assess the reliability and accuracy of the device for measuring blood glucose, it is important to compare its readings to those obtained using a 'gold standard' method, such as the hexokinase method. Therefore, in the present study, canine blood [glucose] measurements using the STG-22 were compared to those obtained using a previously established commercial reagent, Quickauto-Neo GLU-HK. Furthermore, two different sample types (whole blood versus plasma constituent) were compared to determine which sample type results in more accurate and optimal readings with the STG-22. Given that the STG-22 was not primarily designed for canine blood samples, results for canine blood samples were not accurate. Measurements performed by the STG-22 with whole blood were significantly lower than reference [glucose] counterparts. Alternatively, an opposite trend was observed with plasma measurements that were significantly higher. A conversion format using the following formula, Hexokinase [glucose] = STG-22 [glucose] × 1.407 + 1.532, was observed with canine samples in our study.

  9. THE EFFECT OF AVOCADO (PERSEA AMERICANA MILL. LEAVES EXTRACT TOWARDS THE MOUSE'S BLOOD GLUCOSE DECREASE WITH THE GLUCOSE TOLERANCE METHOD

    Directory of Open Access Journals (Sweden)

    Shirly Kumala*, Hesty Utami and Wahyu Kartika Sari

    2013-02-01

    Full Text Available Decrease in blood glucose level test with the use of oral glucose tolerance method from Avocado leaves was carried out. Swiss Webster male mice were divided randomly into five groups. They were negative control, positive control (Glipizide 0.013 mg/20 g BW and three test groups treated with dosage of avocado leaves ethanol extract 0.490 g/kg, 0.980 g/kg and 1.960 g /BW respectively. Experiment was begun with feeding the mice with the test solution followed by feeding glucose solution (1.5 g/kg BW 30 minutes later. Blood glucose levels were assessed using glucometer kit, from zero to 3 hours, at ½ hourly interval. These results analysed by one way ANOVA showed there were significant difference (p<0.05 between Ethanol extract of avocado leaves treated with mice (0.490, 0.980 g/kg BW and control groups. Furthermore, when Tukey’s test was performed, avocado treated mice (1.960g/kg BW reduce glucose level to 64.27%. The effectiveness of this treatment was not significantly different to those treated with glipizide (68.50%.

  10. Daidzin decreases blood glucose and lipid in streptozotocin ...

    African Journals Online (AJOL)

    ISSN: 1596-5996 (print); 1596-9827 (electronic). © Pharmacotherapy ... and inflammation. Inhibition of α-glucosidase and stimulation of glucose consumption by muscles may ..... tissues [26] and increasing insulin sensitivity [27]. Insulinotropic ...

  11. Fasting but not casual blood glucose is associated with pancreatic cancer mortality in Japanese: EPOCH-JAPAN.

    Science.gov (United States)

    Nagai, Masato; Murakami, Yoshitaka; Tamakoshi, Akiko; Kiyohara, Yutaka; Yamada, Michiko; Ukawa, Shigekazu; Hirata, Takumi; Tanaka, Sachiko; Miura, Katsuyuki; Ueshima, Hirotsugu; Okamura, Tomonori

    2017-06-01

    The dose-response relationship between fasting blood glucose levels and risk of pancreatic cancer has been investigated, but the association between casual blood glucose levels and pancreatic cancer death has not been examined. We examined the association between casual and fasting blood glucose levels and death due to pancreatic cancer in Japanese. We performed a pooled analysis of the individual Japanese including 46,387 participants aged 40-79 years from ten cohorts. Participants were classified into five groups: low normal, middle normal, high normal, prediabetes (casual blood glucose 140-199 mg/dl, or fasting blood glucose 110-125 mg/dl), and diabetes (casual blood glucose ≥200 mg/dl, fasting blood glucose ≥126 mg/dl, or anti-diabetic drug use). Low normal, middle normal, and high normal were defined according to tertiles of casual or fasting normal blood glucose levels. Hazard ratios (HRs) and 95% confidence intervals (CIs) for pancreatic cancer mortality were estimated stratifying casual and fasting blood glucose by cohort-stratified Cox proportional hazards regression analysis, with low normal (casual blood glucose <94 mg/dl, or fasting blood glucose <90 mg/dl) as a reference. Fasting blood glucose showed a dose-response relationship with pancreatic cancer mortality (p for trend = 0.005). After adjusting for covariates, HRs (95% CIs) were 2.83 (1.18-6.76) for prediabetes and 3.96 (1.56-10.08) for diabetes. However, there were no significant associations with casual blood glucose. These tendencies were observed after the exclusion of participants who were censored for the first 5 years of follow-up. Fasting blood glucose is a better predictor of pancreatic cancer death than casual blood glucose.

  12. Comparative study of different control techniques for the regulation of blood glucose level in diabetic patients.

    Science.gov (United States)

    Ibbini, Mohammed S

    2009-01-01

    Blood glucose regulation is of a great concern for insulin-dependant patients with excessive glucose in blood (hyperglycaemia), or low glucose profile (hypoglycaemia) due to excess insulin delivery. Both conditions can cause dangerous complications for diabetic patients, and hence glucose regulation in blood is of prime importance. Insulin pumps are used to deliver insulin in small quantities, allowing the glucose level to remain as close as possible to that of non-diabetics (near 100 mg dl(-1)). Different control techniques are used to maintain the glucose level and most of them depend on an exact mathematical or empirical model of insulin-glucose interaction. Recently, we have proposed different controllers that are based on fuzzy logic and so do not use mathematical modelling, which in general is nonlinear, complex and suffers from uncertainties. PI fuzzy controllers are physically related to classical PI and PID controllers, which are extremely popular. The parameter settings of classical and fuzzy logic controllers are based on deep common physical background. In this manuscript, a comparative study is proposed to evaluate the use of fuzzy logic controllers over other conventional controllers such as PI and PID controllers to maintain the blood glucose level within a normoglycaemic average especially when a diabetic patient is subjected to different conditions.

  13. Dietary fiber stabilizes blood glucose and insulin levels and reduces physical activity in sows (Sus scrofa)

    NARCIS (Netherlands)

    Leeuw, de J.A.; Jongbloed, A.W.; Verstegen, M.W.A.

    2004-01-01

    The aim of this study was to test whether a diet with a high level of fermentable dietary fiber can stabilize interprandial blood glucose and insulin levels, prevent declines below basal levels, and reduce physical activity in limited-fed breeding sows. Stable levels of glucose and insulin may preve

  14. Dietary fiber stabilizes blood glucose and insulin levels and reduces physical activity in sows (Sus scrofa)

    NARCIS (Netherlands)

    Leeuw, de J.A.; Jongbloed, A.W.; Verstegen, M.W.A.

    2004-01-01

    The aim of this study was to test whether a diet with a high level of fermentable dietary fiber can stabilize interprandial blood glucose and insulin levels, prevent declines below basal levels, and reduce physical activity in limited-fed breeding sows. Stable levels of glucose and insulin may preve

  15. The Effect of Insulin on the Distribution of Glucose between the Blood Plasma and the Liver

    Science.gov (United States)

    Hetenyi, G.; Arbus, G. S.

    1962-01-01

    In normal fasted rats whole liver tissue contains as much glucose as the blood plasma, i.e., the ratio of the concentrations is about unity. The concentration of glucose in hepatic intracellular water is about 1.2 times higher than in plasma water. In rats injected with insulin the concentration of glucose in the liver falls to a lesser extent than in the plasma: resulting in a ratio of concentrations higher than unity. If insulin hypoglycemia is prevented by the ingestion of glucose the concentration ratio is less than in hypoglycemic rats but still significantly above unity. In normal rats the specific activities of plasma and hepatic glucose do not differ significantly at 7.5, 15, and 30 minutes after the intravenous injection of C14-labeled glucose. In rats injected with insulin the specific activity of glucose is higher in the plasma than in the liver at 7.5 and 15 minutes, but not at 30 minutes following the injection of tracer. In insulin-treated hypoglycemic rats considerably higher concentrations of labeled glucose are found in hepatic intracellular than in plasma water. The penetration of C14-glucose from plasma into hepatic intracellular water is found to be fast. Excess insulin causes an accumulation of glucose within the liver cells by retaining newly formed glucose and by the taking up of glucose from the plasma against an existing concentration gradient. PMID:13907027

  16. Effects of blood glucose level on FDG uptake by liver: a FDG-PET/CT study

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Kazuo, E-mail: kkubota@cpost.plala.or.j [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Watanabe, Hiroshige; Murata, Yuji [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan); Yukihiro, Masashi; Ito, Kimiteru; Morooka, Miyako; Minamimoto, Ryogo [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Hori, Ai [Department of Epidemiology and International Health, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Shibuya, Hitoshi [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan)

    2011-04-15

    In FDG-PET for abdominal malignancy, the liver may be assumed as an internal standard for grading abnormal FDG uptake both in early images and in delayed images. However, physiological variables of FDG uptake by the liver, especially the effects of blood glucose level, have not yet been elucidated. Methods: FDG-PET studies of 70 patients examined at 50 to 70 min after injection (60{+-}10 min: early images) and of 68 patients examined at 80 to 100 min after injection (90{+-}10 min: delayed images) were analyzed for liver FDG uptake. Patients having lesions in the liver, spleen and pancreas; patients having bulk tumor in other areas; and patients early after chemotherapy or radiotherapy were excluded; also, patients with blood glucose level over 125 mg/dl were excluded. Results: Mean standardized uptake value (SUV) of the liver, blood glucose level and sex showed no significant differences between early images and delayed images. However, liver SUV in the delayed image showed a larger variation than that in the early image and showed significant correlation to blood glucose level. The partial correlation coefficient between liver SUV and blood glucose level in the delayed image with adjustment for sex and age was 0.73 (P<.0001). Multivariate regression coefficient (95% confidence interval) of blood glucose was 0.017 (0.013-0.021). Conclusion: Blood glucose level is an important factor affecting the normal liver FDG uptake in nondiabetic patients. In the case of higher glucose level, liver FDG uptake is elevated especially in the delayed image. This may be due to the fact that the liver is the key organ responsible for glucose metabolism through gluconeogenesis and glycogen storage.

  17. Blood Glucose and Cholesterol Concentrations in a Mediterranean Rural Population of Andros Island, Greece

    Directory of Open Access Journals (Sweden)

    Konstantinos T Tsaousis

    2014-01-01

    Conclusions: The present study confirms that dyslipidemia and high blood glucose levels are prevalent among the rural populations of Greece and therefore informative campaigns and structured screening programs are required to promote preventive health care.

  18. Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

    Science.gov (United States)

    De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson

    2016-08-01

    As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.

  19. VIRTUAL DETERMINATION OF BLOOD GLUCOSE OBTAINED FROM FED RATS AND FROM 24-HOUR FASTED RATS

    Directory of Open Access Journals (Sweden)

    Vera Maria Treis Trindade

    2016-11-01

    Full Text Available INTRODUCTION: The normal blood glucose in rats is 100 mg glucose / 100 ml of blood plasma. After a 24hhour fast, a decrease around 30% of this value occurs. This reduction can reach 45% in a prolonged fast. Several processes controlled by neurohormonal mechanisms prevent a more pronounced decrease in blood glucose of animals subjected to fast. These processes are hepatic glycogenolysis, hepatic gluconeogenesis, decrease of glucose utilization and increase of fatty acids use by muscle tissue, and ketone bodies utilization by the central nervous system. OBJECTIVES: This study presents a learning object, mediated by computer, which simulates the determination of blood glucose (glycemia obtained from fed rats and from 24-hour fasted rats. MATERIALS AND METHODS: At first, cartoons were planned in order to show the biochemical and methodology fundamentals. The most representative images were selected, edited and inserted into an animation developed with the aid of the Adobe ® Flash 8 software. DISCUSSION AND RESULTS: The animated simulation of a standard glucose curve, followed by virtual evaluation of glucose in blood plasma samples were developed, associated with some questions. This object has been used by students of Biochemistry I (Pharmacy-UFRGS since second semester of 2009. The navigation features, design and interactivity have been evaluated as excellent by about 80% of them. CONCLUSION: Therefore, this learning object can be considered an adequate teaching resource as well as an innovative support in the construction of theoretical and practical knowledge of Biochemistry. Available at: http://www.ufrgs.br/gcoeb/dosagemglicemia/

  20. Effect of breakfast skipping on diurnal variation of energy metabolism and blood glucose.

    Science.gov (United States)

    Kobayashi, Fumi; Ogata, Hitomi; Omi, Naomi; Nagasaka, Shoichiro; Yamaguchi, Sachiko; Hibi, Masanobu; Tokuyama, Kumpei

    2014-01-01

    Epidemiological studies suggest an association between breakfast skipping and body weight gain, insulin resistance or type 2 diabetes. Time when meal is consumed affects postprandial increase in energy expenditure and blood glucose, and breakfast skipping may reduce 24 h energy expenditure and elevate blood glucose level. The present study evaluated the effect of breakfast skipping on diurnal variation of energy metabolism and blood glucose. The skipped breakfast was compensated by following big meals at lunch and supper. In a randomized repeated-measure design with or without breakfast, eight males stayed twice in a room-size respiratory chamber. Blood glucose was recorded with a continuous glucose monitoring system. Breakfast skipping did not affect 24 h energy expenditure, fat oxidation and thermic effect of food, but increased overall 24 h average of blood glucose (83 ± 3 vs 89 ± 2 mg/dl, P breakfast skipping. These observations suggest that changes in glucose homeostasis precede that of energy balance, in the potential sequence caused by breakfast skipping, if this dietary habit has any effect on energy balance.:

  1. The Health Behavior Schedule-II for Diabetes Predicts Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Frank, Maxwell T.; Cho, Sungkun; Heiby, Elaine M.; Lee, Chun-I; Lahtela, Adrienne L.

    2006-01-01

    The Health Behavior Schedule-II for Diabetes (HBS-IID) is a 27-item questionnaire that was evaluated as a predictor of self-monitoring of blood glucose (SMBG). The HBS-IID was completed by 96 adults with Type 2 diabetes. Recent glycosylated hemoglobin HbA1c and fasting blood glucose results were taken from participants' medical records. Only 31.3%…

  2. Glucometer as a chairside device to assess blood glucose in periodontal patients

    Directory of Open Access Journals (Sweden)

    G N Bala Raghavendra

    2010-01-01

    Full Text Available Background: Diabetes mellitus is a common finding in the medical history of patients receiving treatment for periodontal disease. The incidence of diabetes is on the rise worldwide. Virtually, every dentist and especially the periodontist are likely to encounter an increasing number of undiagnosed diabetic patients. The conventional laboratory methods employed to detect blood glucose are time consuming and require elaborative equipment. The advent of blood glucose monitors allows the clinician to assess blood glucose at the chair side. Materials and Methods: The use of gingival capillary blood as a marker for blood glucose estimation using glucometer against the conventional laboratory method has been assessed in 60 diabetics and 70 controls. Results: The correlation between gingival and finger-stick blood was r = 0.996, P<0.001 in diabetics and controls. Correlation between gingival and laboratory method was r = 0.994, P<0.001 in cases and controls. Conclusion: The results suggest that capillary blood from the outer surface of gingiva provide an acceptable source for measuring blood glucose.

  3. Comparison of blood electrolytes and glucose during cardiopulmonary bypass in diabetic and non-diabetic patients

    Directory of Open Access Journals (Sweden)

    Golamreza Maasoumi

    2013-01-01

    Full Text Available Background: Cardiopulmonary bypass (CPB during coronary artery bypass grafting is thought to contribute significantly to increased blood glucose level and altered blood electrolytes balance during the operation. In this (CABG study, blood electrolytes and glucose during CPB in insulin-dependent diabetic and non-diabetic patients were assessed with special emphasis on the trend of the changes. Materials and Methods: Blood glucose and electrolytes were assessed in 30 insulin-dependent diabetic and 30 non-diabetic patients, classified as class II and III American Society of Anesthesiologist, before, during, and after CPB. Repeated-measures analysis of variance (ANOVA was used to compare the trend of the changes during CPB for the two groups. Results: The trend in blood glucose level did not show any significant difference between two groups ( P = 0.59. For other blood factors, no significant between-group difference was detected except for PaCO 2 ( P = 0.002. Conclusion: The study suggested that the changes in blood electrolytes and the increase in blood glucose level do not differ between insulin dependent diabetic and non-diabetic patients.

  4. Determination of glucose levels using dried filter paper blood spots: new perspective in home monitoring

    Directory of Open Access Journals (Sweden)

    Laura Sterian Ward

    Full Text Available We present a method for the determination of blood glucose using dried filter paper blood spots.To validate this method, we compared our results using filter paper and simultaneously collected venous blood. We demonstrated that there is a linear relationship between the filter paper glucose levels and those determined in whole blood (r=0.98. There was no significant difference between the results of the two methods (p>0.05.This method is a cheap alternative which may improve the control of diabetes mellitus, and may also be very useful in the diagnosis of postprandial hypoglycemia and other special situations.

  5. Blood glucose regulation mechanism in depressive disorder animal model during hyperglycemic states.

    Science.gov (United States)

    Lim, Su-Min; Park, Soo-Hyun; Sharma, Naveen; Kim, Sung-Su; Lee, Jae-Ryeong; Jung, Jun-Sub; Suh, Hong-Won

    2016-06-01

    Depression is more common among diabetes people than in the general population. In the present study, blood glucose change in depression animal model was characterized by various types of hyperglycemia models such as d-glucose-fed-, immobilization stress-, and drug-induced hyperglycemia models. First, the ICR mice were enforced into chronic restraint stress for 2h daily for 2 weeks to produce depression animal model. The animals were fed with d-glucose (2g/kg), forced into restraint stress for 30min, or administered with clonidine (5μg/5μl) supraspinally or spinally to produce hyperglycemia. The blood glucose level in depression group was down-regulated compared to that observed in the normal group in d-glucose-fed-, restraint stress-, and clonidine-induced hyperglycemia models. The up-regulated corticosterone level induced by d-glucose feeding or restraint stress was reduced in the depression group while the up-regulation of plasma corticosterone level is further elevated after i.t. or i.c.v. clonidine administration in the depression group. The up-regulated insulin level induced by d-glucose feeding or restraint stress was reduced in the depression group. On the other hand, blood corticosterone level in depression group was up-regulated compared to the normal group after i.t. or i.c.v. clonidine administration. Whereas the insulin level in depression group was not altered when mice were administered clonidine i.t. or i.c.v. Our results suggest that the blood glucose level in depression group is down-regulated compared to the normal group during d-glucose-fed-, immobilization stress-, and clonidine-induced hyperglycemia in mice. The down-regulation of the blood glucose level might be one of the important pathophysiologic changes in depression.

  6. Waist circumference as a predictor for blood glucose levels in adults

    Directory of Open Access Journals (Sweden)

    Shinta L Hardiman

    2016-02-01

    Full Text Available Anthropometric indexes such as body mass index (BMI, waist circumference (WC, hip ciucumference (HC, and waist–hip ratio (WHR, are all useful anthropometric measurements to provide important information on blood glucose concentrations. The aim of this study was to determine different anthropometric measurements, in particular BMI, waist circumference, hip circumference and waist-to-hip ratio, in their ability to predict the blood glucose levels in men and women 40 to 60. A cross-sectional study was conducted on a sample of 44 men and 127 women aged 40 to 50 who lived in Cipete Selatan subdistrict, South Jakarta. Blood glucose levels was assessed and anthropometric measurements comprising BMI, WC, HC, WHR were collected. Multiple linear regression analysis was used to determine the best predictor for blood glucose levels. The study showed that the prevalence of DM type 2 was 25.7% and the prevalence was higher in men (40.9% compared to women (23.5%. The significant predictive variables in the simple regression analysis were age and waist circumference. Multiple linear regression showed that after adjustment for age, WC was positively associated with blood glucose levels. Standardized a value was 0.172 (p=0.026. WC predict blood glucose levels, beyond that explained by traditional diabetic risk factors and BMI. These findings provide support for the recommendation that WC be a routine measure for identification of diabetes mellitus type 2 in men and women aged 40 to 60 years.

  7. EFFECT OF SAPPAN WOOD (Caesalpinnia sappan L EXTRACT ON BLOOD GLUCOSE LEVEL IN WHITE RATS

    Directory of Open Access Journals (Sweden)

    Saefudin Saefudin

    2016-05-01

    Full Text Available Sappan wood or kayu secang (Caesalpinia sappan L. was reported of having medicinal properties, such as natural antioxidant, relieve vomiting of blood, and mix of ingredients for malaria drugs. The research was conducted to study the influence of ethanol extract from sappan wood on blood glucose level of white rats. The study of the blood glucose level in rats was carried out by using glucose tolerance method. It was measured by Refloluxs (Accutrend GC with Chloropropamide 50 mg/200 g BW (Body weight as positive control. The ethanol extracts were used in various concentrations 10, 20, 30, 40 and 50 mg/200 g BW per-oral and was observed every hour, beginning one hour before to 7 hours after the extract being administered. The results showed that treatment of ethanol extract of sappan wood by administer doses gave remarkable effect on the blood glucose level in white rat. It reduced the glucose level in the blood compared to the negative and positive control. Treatment of dose 30 mg/200 g BW gave similar effect to positive controls, while a dose of 50 mg/200 g BW gave lower blood glucose level (93 mg/dl than the positive controls.

  8. Insoluble Fiber in Young Barley Leaf Suppresses the Increment of Postprandial Blood Glucose Level by Increasing the Digesta Viscosity

    Directory of Open Access Journals (Sweden)

    Akira Takano

    2013-01-01

    Full Text Available Barley (Hordeum vulgare L. is a well-known cereal plant. Young barley leaf is consumed as a popular green-colored drink, which is named “Aojiru” in Japan. We examined the effects of barley leaf powder (BLP and insoluble fibers derived from BLP on postprandial blood glucose in rats and healthy Japanese volunteers. BLP and insoluble fibers derived from BLP suppressed the increment of postprandial blood glucose levels in rats (, and increased the viscosity of their digesta. The insoluble fibers present in BLP might play a role in controlling blood glucose level by increasing digesta viscosity. In human, BLP suppressed the increment of postprandial blood glucose level only in those which exhibited higher blood glucose levels after meals (. BLP might suppress the increment of postprandial blood glucose level by increasing digesta viscosity in both of rats and humans who require blood glucose monitoring.

  9. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors.

    Science.gov (United States)

    Mortazavi, Smj; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, Ar

    2014-09-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test). To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors.

  10. The relationships between blood pressure, blood glucose, and bone mineral density in postmenopausal Turkish women

    Directory of Open Access Journals (Sweden)

    Cakmak HA

    2015-10-01

    Full Text Available Huseyin Altug Cakmak,1 Burcu Dincgez Cakmak,2 Ayse Ender Yumru,3 Serkan Aslan,4 Asim Enhos,1 Ali Kemal Kalkan,4 Ebru Inci Coskun,5 Abdullah Serdar Acikgoz,6 Suat Karatas3 1Department of Cardiology, Mustafakemalpasa Government Hospital, Bursa, 2Department of Obstetric and Gynecology, Rize Kackar Government Hospital, Rize, 3Department of Obstetric and Gynecology, Sisli Hamidiye Etfal Training and Research Hospital, 4Department of Cardiology, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, 5Department of Obstetric and Gynecology, Inonu University, Malatya, 6Department of Obstetric and Gynecology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey Background: Hypertension, diabetes mellitus, and osteoporosis are important comorbidities commonly seen in postmenopausal women. The aim of the present study was to investigate the relationships between blood pressure, blood glucose, and bone mineral density (BMD in postmenopausal Turkish women.Methods: In this cross-sectional study, 270 consecutive patients who were admitted to an outpatient clinic with vasomotor symptoms and/or at least 1 year of amenorrhea were included. The patients were categorized into three groups according to their blood pressure and metabolic status as follows: normotensive, hypertensive nondiabetics, and hypertensive diabetics. The T- and z-scores of the proximal femur and lumbar vertebrae were measured with the dual-energy X-ray absorptiometry method to assess the BMD of the study groups.Results: Lumbar vertebral T-scores (P<0.001, lumbar vertebral z-scores (P<0.003, and proximal femoral T-scores (P<0.001 were demonstrated to be significantly lower in the hypertensive diabetic group compared to the hypertensive nondiabetic and normotensive groups. Systolic blood pressure was significantly inversely correlated with lumbar vertebral T-scores (r=-0.382; P=0.001, lumbar vertebral z-scores (r=-0.290; P=0.001, and

  11. Energized by love: thinking about romantic relationships increases positive affect and blood glucose levels.

    Science.gov (United States)

    Stanton, Sarah C E; Campbell, Lorne; Loving, Timothy J

    2014-10-01

    We assessed the impact of thinking of a current romantic partner on acute blood glucose responses and positive affect over a short period of time. Participants in romantic relationships were randomly assigned to reflect on their partner, an opposite-sex friend, or their morning routine. Blood glucose levels were assessed prior to reflection, as well as at 10 and 25 min postreflection. Results revealed that individuals in the routine and friend conditions exhibited a decline in glucose over time, whereas individuals in the partner condition did not exhibit this decline (rather, a slight increase) in glucose over time. Reported positive affect following reflection was positively associated with increases in glucose, but only for individuals who reflected on their partner, suggesting this physiological response reflects eustress. These findings add to the literature on eustress in relationships and have implications for relationship processes.

  12. Photoacoustic blood glucose and skin measurement based on optical scattering effect

    Science.gov (United States)

    Zhao, Zuomin; Myllyla, Risto A.

    2002-07-01

    Non-invasive blood glucose determination has been investigated by more than 100 research groups in the world during the past fifteen years. The commonly optical methods are based on the capacity of near-IR light to penetrate a few hundreds micrometers or a few millimeters into human tissue where it interacts with glucose. A change of glucose concentration may modify the optical parameters in tissue, with the result that its glucose concentration can be extracted by analyzing the received optical signals. This paper demonstrates that glucose affects on the scattering coefficient of human blood, by applying the streak camera and pulsed photoacoustic techniques; and drinking water seems also affecting on PA signal from skin surface.

  13. Isolation and Biochemical Characterization of a Glucose Dehydrogenase from a Hay Infusion Metagenome

    OpenAIRE

    Alexander Basner; Garabed Antranikian

    2014-01-01

    Glucose hydrolyzing enzymes are essential to determine blood glucose level. A high-throughput screening approach was established to identify NAD(P)-dependent glucose dehydrogenases for the application in test stripes and the respective blood glucose meters. In the current report a glucose hydrolyzing enzyme, derived from a metagenomic library by expressing recombinant DNA fragments isolated from hay infusion, was characterized. The recombinant clone showing activity on glucose as substrate ex...

  14. Institutional point-of-care glucometer identifies population trends in blood glucose associated with war.

    Science.gov (United States)

    Boaz, Mona; Matas, Zipora; Chaimy, Tova; Landau, Zohar; Bar Dayan, Yosefa; Berlovitz, Yitzhak; Wainstein, Julio

    2013-11-01

    Acute physiological stress has been shown to impair glucose homeostasis. War is a period of acute psychological stress, and its effect on glucose control is unknown. In this study random point-of-care (POC) glucose levels were measured using an automated, institutional glucometer in hospitalized adult patients prior to versus during the Israeli Pillar of Defense campaign (November 7-10, 2012). Random POC glucose values measured with the institutional blood glucose monitoring system were obtained 1 week prior to the Pillar of Defense campaign (November 7-10, 2012) and compared with values to those obtained during the first 4 days of the war (November 14-17, 2012). In total, 3,573 POC glucose measures were included: 1,865 during the pre-war period and 1,708 during the campaign. POC glucose measures were significantly higher during the war compared with the week preceding the war: 9.7±4.7 versus 9.3±4.2 mmol/L (P=0.02). In a general linear model, period (pre-war vs. during war) persisted as a significant predictor of POC glucose even after controlling for age, sex, and department type (internal medicine vs. surgical). Acute stress, such as a wartime situation, is associated with a significant increase in random blood glucose values in a population of hospitalized adults. Long-term follow-up of the individuals hospitalized during these two periods can reveal differences in morbidity and mortality trends.

  15. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    Science.gov (United States)

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  16. Proportional Insulin Infusion in Closed-Loop Control of Blood Glucose

    Science.gov (United States)

    Grasman, Johan

    2017-01-01

    A differential equation model is formulated that describes the dynamics of glucose concentration in blood circulation. The model accounts for the intake of food, expenditure of calories and the control of glucose levels by insulin and glucagon. These and other hormones affect the blood glucose level in various ways. In this study only main effects are taken into consideration. Moreover, by making a quasi-steady state approximation the model is reduced to a single nonlinear differential equation of which parameters are fit to data from healthy subjects. Feedback provided by insulin plays a key role in the control of the blood glucose level. Reduced β-cell function and insulin resistance may hamper this process. With the present model it is shown how by closed-loop control these defects, in an organic way, can be compensated with continuous infusion of exogenous insulin. PMID:28060898

  17. Measurement of tissue optical properties with optical coherence tomography: Implication for noninvasive blood glucose concentration monitoring

    Science.gov (United States)

    Larin, Kirill V.

    Approximately 14 million people in the USA and more than 140 million people worldwide suffer from diabetes mellitus. The current glucose sensing technique involves a finger puncture several times a day to obtain a droplet of blood for analysis. There have been enormous efforts by many scientific groups and companies to quantify glucose concentration noninvasively using different optical techniques. However, these techniques face limitations associated with low sensitivity, accuracy, and insufficient specificity of glucose concentrations over a physiological range. Optical coherence tomography (OCT), a new technology, is being applied for noninvasive imaging in tissues with high resolution. OCT utilizes sensitive detection of photons coherently scattered from tissue. The high resolution of this technique allows for exceptionally accurate measurement of tissue scattering from a specific layer of skin compared with other optical techniques and, therefore, may provide noninvasive and continuous monitoring of blood glucose concentration with high accuracy. In this dissertation work I experimentally and theoretically investigate feasibility of noninvasive, real-time, sensitive, and specific monitoring of blood glucose concentration using an OCT-based biosensor. The studies were performed in scattering media with stable optical properties (aqueous suspensions of polystyrene microspheres and milk), animals (New Zealand white rabbits and Yucatan micropigs), and normal subjects (during oral glucose tolerance tests). The results of these studies demonstrated: (1) capability of the OCT technique to detect changes in scattering coefficient with the accuracy of about 1.5%; (2) a sharp and linear decrease of the OCT signal slope in the dermis with the increase of blood glucose concentration; (3) the change in the OCT signal slope measured during bolus glucose injection experiments (characterized by a sharp increase of blood glucose concentration) is higher than that measured in

  18. [Evaluation of fructosamine as a parameter of blood glucose control in diabetic pregnant women].

    Science.gov (United States)

    Feitosa, Alina Coutinho Rodrigues; Andrade, Flávio Silva

    2014-10-01

    To evaluate the alternative parameters to monitor glycemia in pregnant women with diabetes studying the relationship between fructosamine testing and self monitoring of blood glucose in pregnant women with diabetes. Serum fructosamine levels and the self monitoring of blood glucose over 14 days before the collection of fructosamine were evaluated in 47 diabetic pregnant women. Seventy-one fructosamine levels and 2,238 glucose measurements (CGs) were analysed. Levels of fructosamine correlated with high blood glucose index (HBGI) and the standard deviation of glycemias (r = 0.28; p = 0.021 and r = 0.26; p = 0.03, respectively). The comparison between the mothers of the newborns with appropriated or large birthweight and those who gave birth to small newborns for their gestational age (SGA) showed that the latter had a lower glycemic mean (105 vs. 114 and 119 mg/dL), a higher low blood glucose index (5.8 vs. 1.3 and 0.7) and a higher percentage of hyperglycemias (11 vs. 0 and 0%) even when the fructosamine falls within the reference values (242 vs. 218 and 213 μmol/l). The levels of fructosamine can be used as further parameter to aid self monitoring of blood glucose to evaluate hyperglycemias and glycemic variability, however, this can underestimate hypoglycemias in pregnant women carrying small-for-gestational age fetuses.

  19. The associations of a marine diet with plasma lipids, blood glucose, blood pressure and obesity among the inuit in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, P; Pedersen, H S; Mulvad, G

    2000-01-01

    OBJECTIVE: To analyse the associations between the intake of fish and marine mammals and risk factors for cardiovascular disease, ie lipid profile, fasting blood glucose, blood pressure and obesity, in a population whose average consumption of n-3 fatty acids is high compared with Western countries...... was positively associated with serum high-density lipoprotein (HDL) and blood glucose and inversely with very-low-density lipoprotein (VLDL) and triglyceride. Association with low-density lipoprotein (LDL), diastolic and systolic blood pressure, waist-hip ratio and body mass index were inconsistent...... and not statistically significant. The pattern was similar within groups with low, medium and high consumption of marine food. CONCLUSIONS: There are statistically significant associations between the consumption of marine food and certain lipid fractions in the blood also in this population with a very high average...

  20. Development of the MOSFET hybrid biosensor for self-monitoring of blood glucose

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Kuroda, Tatsuro; Hirai, Yasutomo; Iwamoto, Naoyuki; Nakanishi, Naoyuki; Uetsuji, Yasutomo; Nakamachi, Eiji

    2006-01-01

    We focus on the research to develop a compact Self Monitoring of Blood Glucose (SMBG). The SMBG consists of (1) a micro electrical pumping system for blood extraction, (2) a painless microneedle as same size as a female mosquito's labium and (3) a biosensor to detect and evaluate an amount of glucose in extracted blood, by using enzyme such as glucose oxidase (GOx). A gold (Au) plate immobilized GOx was used as a biosensor and attached to the gate electrode of MOSFET. GOx was immobilized on a self-assembled spacer combined with an Au electrode by the cross-link method using BSA (bovine serum albumin) as an additional bonding material. The electrode could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose using the constant electric current measurement system of the MOSFET type hybrid biosensor system. The system can measure the change of gate voltage. The extracting speed for whole blood using the micro electrical pumping system was about 2 μl/min. The extracted volume was sufficient to determine the glucose level in the blood; it was comparable to the volume extracted in a commercial glucose level monitor. In the functional evaluation of the biosensor system using hydrogen peroxide solution, it is shown that the averaged output voltage increases in alignment to hydrogen peroxide concentration. The linear value was shown with the averaged output voltage in corresponding hydrogen peroxide concentration with the averaged output voltage obtained from the biosensor system by glucose solution concentration. Furthermore, it is confirmed that the averaged output voltage from the biosensor system obtained by whole blood showed the same voltage in corresponding glucose solution concentration. The hybrid biosensor obtained the useful performance for the SMBG.

  1. On the suitability of refractometry for the analysis of glucose in blood-derived fluids.

    Science.gov (United States)

    Zirk, K; Poetzschke, H

    2004-07-01

    Refractometry is the determination of the optical refractive index of a substance or a mixture of substances. It is a very sensitive method for the detection and quantification of dissolved analytes, but it is incapable of distinguishing between different analytes. The aim of this investigation was to determine the principle suitability of refractometry for the quantification of glucose (blood sugar) in blood and various blood fluids which can readily be obtained for medical diagnosis, in particular blood plasma, blood serum, and their ultrafiltrates. After the oral intake of freshly dissolved alpha-glucose, the in vivo blood contents of the alpha and beta anomers of glucose were found to be in an at least approximate equilibrium at all times. This observation is a prerequisite for a refractometrical determination of glucose due to the fact that both molecule forms have different refractive index increments. An assessment of the glucose content in untreated blood fluids was not possible, since no suitable relationship to the refractive index was found, most probably due to the influence of the many other substances present in blood on this parameter. However, after removal of certain macromolecules by ultrafiltration, value pairs showed a high level of correlation, providing the nominal molecular weight limit (cut-off) of the ultrafilter used possessed a maximum of 300 kDa. Besides macromolecules, the osmolality of the fluids undergoing measurement also proved to be a considerable interfering factor, particularly when values were outside the normal physiological range between 285 and 293 mmol/L. If a clinical application of this method is to be contemplated it is imperative (1) that blood cells are separated and removed, (2) that macromolecules present in plasma or serum are removed, e.g. by ultrafiltration, and (3) that beyond the results presented the influence of all small molecules other than glucose on the overall refractive index be determined and included in

  2. Self-Monitoring of Blood Glucose : Professional Advice and Daily Practice of Patients With Diabetes

    NARCIS (Netherlands)

    Hortensius, Johanna; van der Bijl, Jaap J.; Kleefstra, Nanne; Houweling, Sebastiaan T.; Bilo, Henk J. G.

    2012-01-01

    Purpose This study investigated the advice given by diabetes educators in Europe, and the daily practice of Dutch patients with diabetes regarding the use of the first or second drop of blood and other aspects concerning self-monitoring of blood glucose (SMBG). Method During a diabetes conference in

  3. Social Inclusion Predicts Lower Blood Glucose and Low-Density Lipoproteins in Healthy Adults.

    Science.gov (United States)

    Floyd, Kory; Veksler, Alice E; McEwan, Bree; Hesse, Colin; Boren, Justin P; Dinsmore, Dana R; Pavlich, Corey A

    2016-07-27

    Loneliness has been shown to have direct effects on one's personal well-being. Specifically, a greater feeling of loneliness is associated with negative mental health outcomes, negative health behaviors, and an increased likelihood of premature mortality. Using the neuroendocrine hypothesis, we expected social inclusion to predict decreases in both blood glucose levels and low-density lipoproteins (LDLs) and increases in high-density lipoproteins (HDLs). Fifty-two healthy adults provided self-report data for social inclusion and blood samples for hematological tests. Results indicated that higher social inclusion predicted lower levels of blood glucose and LDL, but had no effect on HDL. Implications for theory and practice are discussed.

  4. Effect of mitiglinide combined laser photocoagulation on blood glucose, blood lipid and vascular endothelial function in diabetic retinopathy

    Institute of Scientific and Technical Information of China (English)

    Yun-Yan Fan; Gui-Jun Luo

    2016-01-01

    Objective:To observe the effect of mitiglinide combined laser photocoagulation on blood glucose, blood lipid and vascular endothelial function in diabetic retinopathy.Methods:A total of 106 patients with diabetic retinopathy treated in our hospital from January 2014 to January 2015 were selected and assigned into the separate group and combined group. Fifty-three patients in the separate group only received oral mitiginide, while other 53 patients in the combined group received oral mitiglinide and laster photocoagulation surgery. Before and after treatment, the FBG, 2hPBG, HbA1c, TC, TG, HDL-C, LDL-C, ET-1, VEGF, PEDF, ICAM-1, FMD of patients in the two groups were analyzed.Results: After treatment, the blood glucose and blood lipid indexes of patients in the two groups were improved significantly, and there was no statistical difference between the two groups. The ET-1, ICAM-1 and VEGF of patients in the two groups decreased, and the decrease of the combined group was more distinctly. The PEDF and FMD in the two groups all increased, and the combined group changed more obviously. The regression of the blood vessel and the recovery of visual acuity in the combined group were better than the separate group.Conclusions:Mitiglinide combined with laser photocoagulation can effectively improve the level of blood glucose and blood lipid, promote vascular endothelial function and inhibit the formation of retinal neovascularization so as to improve the visual acuity level.

  5. Chinese herbal medicines for people with impaired glucose tolerance or impaired fasting blood glucose.

    Science.gov (United States)

    Grant, Suzanne J; Bensoussan, Alan; Chang, Dennis; Kiat, Hosen; Klupp, Nerida L; Liu, Jian Ping; Li, Xun

    2009-10-07

    Around 308 million people worldwide are estimated to have impaired glucose tolerance (IGT); 25% to 75% of these will develop diabetes within a decade of initial diagnosis. At diagnosis, half will have tissue-related damage and all have an increased risk for coronary heart disease. The objective of this review was to assess the effects and safety of Chinese herbal medicines for the treatment of people with impaired glucose tolerance or impaired fasting glucose (IFG). We searched the following databases: The Cochrane Library, PubMed, EMBASE, AMED, a range of Chinese language databases, SIGLE and databases of ongoing trials. Randomised clinical trials comparing Chinese herbal medicines with placebo, no treatment, pharmacological or non-pharmacological interventions in people with IGT or IFG were considered. Two authors independently extracted data. Trials were assessed for risk of bias against key criteria: random sequence generation, allocation concealment, blinding of participants, outcome assessors and intervention providers, incomplete outcome data, selective outcome reporting and other sources of bias. This review examined 16 trials lasting four weeks to two years involving 1391 participants receiving 15 different Chinese herbal medicines in eight different comparisons. No trial reported on mortality, morbidity or costs. No serious adverse events like severe hypoglycaemia were observed. Meta-analysis of eight trials showed that those receiving Chinese herbal medicines combined with lifestyle modification were more than twice as likely to have their fasting plasma glucose levels return to normal levels (i.e. fasting plasma glucose lifestyle modification alone (RR 2.07; 95% confidence intervall (CI) 1.52 to 2.82). Those receiving Chinese herbs were less likely to progress to diabetes over the duration of the trial (RR 0.33; 95% CI 0.19 to 0.58). However, all trials had a considerable risk of bias and none of the specific herbal medicines comparison data was

  6. Local cerebral blood flow and glucose metabolism during seizure in spontaneously epileptic El mice

    Energy Technology Data Exchange (ETDEWEB)

    Hosokawa, Chisa; Ochi, Hironobu; Yamagami, Sakae; Kawabe, Joji; Kobashi, Toshiko; Okamura, Terue; Yamada, Ryusaku [Osaka City Univ. (Japan). Faculty of Medicine

    1995-09-01

    Local cerebral blood flow and glucose metabolism were examined in spontaneously epileptic El mice using autoradiography with {sup 125}I-IMP and {sup 14}C-DG in the interictal phase and during seizure. El (+) mice that developed generalized tonic-clonic convulsions and El (-) mice that received no stimulation and had no history of epileptic seizures were examined. The seizure non-susceptible, maternal strain ddY mice were used as control. Uptake ratios for IMP and DG in mouse brain were calculated using the autoradiographic density. In the interictal phase, the pattern of local cerebral blood flow of El (+) mice was similar to that of ddY and El (-) mice, and glucose metabolism in the hippocampus was higher in El (+) mice than in El (-) and ddY mice, but flow and metabolism were nearly matched. During seizure, no significant changed blood flow and increased glucose metabolism in the hippocampus, the epileptic focus, and no markedly changed blood flow and depressed glucose metabolism in other brain regions were observed and considered to be flow-metabolism uncoupling. These observations have never been reported in clinical or experimental studies of epilepsy. Seizures did not cause large regional differences in cerebral blood flow. Therefore, only glucose metabolism is useful for detection of the focus of secondary generalized seizures in El mice, and appeared possibly to be related to the pathophysiology of secondary generalized epilepsy in El mice. (author).

  7. How Effective is Swedish Massage on Blood Glucose Level in Children with Diabetes Mellitus?

    Directory of Open Access Journals (Sweden)

    Firoozeh Sajedi

    2011-09-01

    Full Text Available "nThis study was conducted to determine the effect of Swedish massage on blood glucose level in children with diabetes mellitus (DM. It was prospective randomized controlled trial study that conducted on 36 children, 6-12 years old with DM, recruited from a hospital in Qom City, Iran. The children were randomly assigned to intervention and control groups. Swedish massage was performed 15 minutes, 3 times a week, for 3 months in intervention group. The blood glucose levels were evaluated immediately after every session of massage in two groups. The mean ages of children in the intervention (n=18 and control (n=18 groups were 9.05 ± 1.55 and 9.83 ±2.03 years respectively. There was statistically no significant difference in blood glucose levels before intervention between two groups (P=0.586, but the blood glucose levels were lower significantly in intervention group in comparison with control group after intervention (P<0.0001. Addition of Swedish massage to daily routines; exercise, diet and medication regimens, is an effective intervention to reduce blood glucose level in diabetic children.

  8. Color record in self-monitoring of blood glucose improves glycemic control by better self-management.

    Science.gov (United States)

    Nishimura, Akiko; Harashima, Shin-ichi; Honda, Ikumi; Shimizu, Yoshiyuki; Harada, Norio; Nagashima, Kazuaki; Hamasaki, Akihiro; Hosoda, Kiminori; Inagaki, Nobuya

    2014-07-01

    Color affects emotions, feelings, and behaviors. We hypothesized that color used in self-monitoring of blood glucose (SMBG) is helpful for patients to recognize and act on their glucose levels to improve glycemic control. Here, two color-indication methods, color record (CR) and color display (CD), were independently compared for their effects on glycemic control in less frequently insulin-treated type 2 diabetes. One hundred twenty outpatients were randomly allocated to four groups with 2×2 factorial design: CR or non-CR and CD or non-CD. Blood glucose levels were recorded in red or blue pencil in the CR arm, and a red or blue indicator light on the SMBG meter was lit in the CD arm, under hyperglycemia or hypoglycemia, respectively. The primary end point was difference in glycated hemoglobin (HbA1c) reduction in 24 weeks. Secondary end points were self-management performance change and psychological state change. HbA1c levels at 24 weeks were significantly decreased in the CR arm by -0.28% but were increased by 0.03% in the non-CR arm (P=0.044). In addition, diet and exercise scores were significantly improved in the CR arm compared with the non-CR arm. The exercise score showed significant improvement in the CD arm compared with the non-CD arm but without a significant difference in HbA1c reduction. Changes in psychological states were not altered between the arms. CR has a favorable effect on self-management performance without any influence on psychological stress, resulting in improved glycemic control in type 2 diabetes patients using less frequent insulin injection. Thus, active but not passive usage of color-indication methods by patients is important in successful SMBG.

  9. Lack of correlation of glucose levels in filtered blood plasma to density and conductivity measurements.

    Science.gov (United States)

    Gordon, David M; Ash, Stephen R

    2009-01-01

    The purpose of this research project was to determine whether the glucose level of a blood plasma sample from a diabetic patient could be predicted by measuring the density and conductivity of ultrafiltrate of plasma created by a 30,000 m.w. cutoff membrane. Conductivity of the plasma filtrate measures electrolyte concentration and should correct density measurements for changes in electrolytes and water concentration. In vitro studies were performed measuring conductivity and density of solutions of varying glucose and sodium chloride concentrations. Plasma from seven hospitalized patients with diabetes was filtered across a 30,000 m.w. cutoff membrane. The filtrate density and conductivity were measured and correlated to glucose levels. In vitro studies confirmed the ability to predict glucose from density and conductivity measurements, in varying concentrations of glucose and saline. In plasma filtrate, the conductivity and density measurements of ultrafiltrate allowed estimation of glucose in some patients with diabetes but not others. The correlation coefficient for the combined patient data was 0.45 which was significant but only explained 20% of the variability in the glucose levels. Individually, the correlation was significant in only two of the seven patients with correlation coefficients of 0.79 and 0.88. The reasons for lack of correlation are not clear, and cannot be explained by generation of idiogenic osmoles, effects of alcohol dehydrogenase, water intake, etc. This combination of physical methods for glucose measurement is not a feasible approach to measuring glucose in plasma filtrate.

  10. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  11. Self-monitoring of blood glucose improved glycaemic control and 10-year coronary heart disease risk profile of type 2 diabetic patients

    Institute of Scientific and Technical Information of China (English)

    Ezenwaka Chidum; JonesLeCointe Altheia; Dimgba Agbai; Okali Fidelis; Skinner Teppany; Rodriguez Martina; Extavour Rian; Davis Verdine; Spencer Alida; Mayers Hasina

    2011-01-01

    Background The debate over the overall benefits of self-monitoring of blood glucose in type 2 diabetes patients is still continuing.We aimed to assess the difference in glycaemic control and coronary heart disease (CHD) risk levels of experimental type 2 diabetes patients provided with facilities for self-monitoring blood glucose and their counterparts without such facilities.Methods Sixty-one patients who had no prior experience in using glucometers were studied as intervention (n=30) and control (n=31) groups.The intervention group was trained in self-monitoring of blood glucose and documentation.Baseline blood glucose and fasting blood glucose were measured and the intervention patients were provided with glucometers and advised to self-monitor their fasting and postprandial blood glucose over six months.The 10-year CHD risk levels were determined with the United Kingdom Prospective Diabetes Study-derived risk engine calculator.Results The age and diabetes duration were similar in the two groups (P >0.05).The majority of the patients were unemployed or retired females with only a primary level education.After 3 months,the haemogolbin A1c (HbA1c) levels of the control patients remained unchanged ((7.8±0.3)% vs.(7.9±0.4)%,P >0.05) whereas the HbA1c levels of the intervention patients were significantly reduced from the baseline at three ((9.6±0.3)% vs.(7.8±0.3)%,P <0.001) and six ((9.2±0.4)% vs.(7.5±0.3)%,P <0.001) months.Interestingly,while the 10-year CHD risk level of the control group remained unchanged after three months,that of the intervention group was remarkably reduced at three and six months from the baseline level ((7.4±1.3)% vs.(4.5±0.9)%,P=0.056).Conclusion Self-monitoring of blood glucose in type 2 diabetes patients significantly improved glycaemic control and the CHD risk profile,suggesting that type 2 diabetes patients will potentially benefit from inclusion of glucose meters and testing strips in their health-care package.

  12. Dextrose in the banked blood products does not seem to affect the blood glucose levels in patients undergoing liver transplantation

    Institute of Scientific and Technical Information of China (English)

    Kwok-Wai Cheng; King-Wah Chiu; Shih-Hor Wang; Chih-Che Lin; Tsan-Shiun Lin; Yueh-Wei Liu; Bruno Jawan; Chao-Long Chen; Yu-Fan Cheng; Chia-chih Tseng; Chih-Hsien Wang; Yaw-Sen Chen; Chih-Chi Wang; Tung Liang Huang; Hock-Liew Eng

    2005-01-01

    AIM: Hyperglycemia commonly seen in liver transplantation (LT) has often been attributed to the dextrose in the storage solution of blood transfusion products. The purpose of the study is to compare the changes of the blood glucose levels in transfused and non-transfused patients during LT. METHODS: A retrospective study on 60 biliary pediatric patients and 16 adult patients undergoing LT was carried out. Transfused pediatric patients were included in Group Ⅰ (GI), those not transfused in Group Ⅱ (GⅡ). Twelve adult patients were not given transfusion and assigned to Group Ⅲ (GⅢ); whereas, four adult patients who received massive transfusion were assigned to Group Ⅳ (GⅣ). The blood glucose levels, volume of blood transfused, and the volume of crystalloid infused were recorded, compared and analyzed. RESULTS: Results showed that the changes in bloodglucose levels during LT for both non-transfused and minimally transfused pediatric groups and non-transfused and massively-transfused adult groups were almost the same. CONCLUSION: We conclude that blood transfusion does not cause significant changes in the blood glucose levels inthis study.

  13. Some thoughts on the importance of insulin in the regulation of the blood glucose level.

    Science.gov (United States)

    Newsholme, E A; Dimitriadis, G

    1996-05-15

    Insulin can influence rates of glucose utilization by muscle and possibly other tissues via both direct and indirect effects. It can control the rate of fatty acid mobilization from adipose tissue and the rate of fatty acid oxidation in muscle, and the latter inhibits glucose utilization and oxidation. Insulin may influence the levels of insulin-like growth factors I and II, both of which have effects on rates of glucose utilization by muscle. The inter-tissue cycle between glucose and lactate-the Cori cycle, which is influenced by insulin-may provide another novel mechanism for control of blood glucose. How far other anti-insulin hormones affect these processes is not clear.

  14. Blood Glucose and Cholesterol Concentrations in a Mediterranean Rural Population of Andros Island, Greece

    OpenAIRE

    Tsaousis, Konstantinos T.

    2014-01-01

    Background: This study conducted as part of a screening program for the promotion of community health in the primary care setting of Ormos Korthi in Andros, Greece. The objective of this study was to identify the levels of glucose and total cholesterol in individuals without major cardiovascular problems in order to identify cases of undetected dyslipidemia and high blood glucose levels, in a rural population located in the southern part of Andros Island, Greece. Methods: In total, 242 in...

  15. Chronotopic and blood pressure response to oral glucose load in chagas' disease

    Directory of Open Access Journals (Sweden)

    Maria Elena Guariento

    Full Text Available Cardiac chronotropic and pressor responses after an oral load of glucose were assessed in sixteen Chagasic subjects and 28 controls by means of blood pressure and pulse rate measurements. Cardiovascular response was correlated with serum insulin and glucose levels. The experiment identified a subgroup of Chagasic subjects (n=8 with a hypoinsulinemic behavior presenting less chronotropic and pressor responses than controls. This may indicate a lower insulin activity and/or an early Autonomic Nervous System dysfunction in this subgroup.

  16. Low Red Blood Cell Vitamin C Concentrations Induce Red Blood Cell Fragility: A Link to Diabetes Via Glucose, Glucose Transporters, and Dehydroascorbic Acid

    Directory of Open Access Journals (Sweden)

    Hongbin Tu

    2015-11-01

    Full Text Available Strategies to prevent diabetic microvascular angiopathy focus on the vascular endothelium. Because red blood cells (RBCs are less deformable in diabetes, we explored an original concept linking decreased RBC deformability to RBC ascorbate and hyperglycemia. We characterized ascorbate concentrations from human and mouse RBCs and plasma, and showed an inverse relationship between RBC ascorbate concentrations and deformability, measured by osmotic fragility. RBCs from ascorbate deficient mice were osmotically sensitive, appeared as spherocytes, and had decreased β-spectrin. These aberrancies reversed with ascorbate repletion in vivo. Under physiologic conditions, only ascorbate's oxidation product dehydroascorbic acid (DHA, a substrate for facilitated glucose transporters, was transported into mouse and human RBCs, with immediate intracellular reduction to ascorbate. In vitro, glucose inhibited entry of physiologic concentrations of dehydroascorbic acid into mouse and human RBCs. In vivo, plasma glucose concentrations in normal and diabetic mice and humans were inversely related to respective RBC ascorbate concentrations, as was osmotic fragility. Human RBC β-spectrin declined as diabetes worsened. Taken together, hyperglycemia in diabetes produced lower RBC ascorbate with increased RBC rigidity, a candidate to drive microvascular angiopathy. Because glucose transporter expression, DHA transport, and its inhibition by glucose differed for mouse versus human RBCs, human experimentation is indicated.

  17. Overnight Control of Blood Glucose in People with Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe

    2012-01-01

    In this paper, we develop and test a Model Predictive Controller (MPC) for overnight stabilization of blood glucose in people with type 1 diabetes. The controller uses glucose measurements from a continuous glucose monitor (CGM) and its decisions are implemented by a continuous subcutaneous insulin...... infusion (CSII) pump. Based on a priori patient information, we propose a systematic method for computation of the model parameters in the MPC. Safety layers improve the controller robustness and reduce the risk of hypoglycemia. The controller is evaluated in silico on a cohort of 100 randomly generated...

  18. Blood glucose responses of diabetes mellitus type II patients to some local fruits.

    Science.gov (United States)

    Guevarra, M T; Panlasigui, L N

    2000-12-01

    To determine the glucose responses of diabetes mellitus type II subjects to fruits, four locally available fruits (containing 25 g of available carbohydrates per serving portion) of chico, mango, pineapple, and papaya were tested among ten type II diabetic subjects, using wheat bread as the control. Results of the in vivo test indicated that chico and mango had significantly lower (P ≤ 0.05) blood glucose areas compared to wheat bread. Chico and mango also had a much lower glycemic index (GI), 57 and 59, respectively, compared to pineapple, 73 and papaya, 86. Differences in glucose responses to fruits and their varying GI are attributed to the amount of fiber, type and amount of sugars found, presence of antinutrients, acidity and physical characteristics of the fruits when chewed. The high fiber content of chico (7.9%), its fructose content (5.3%), its grainy texture when chewed and the presence of antinutrients (saponin, sapotin and achrasaponin) may contribute to its slow digestion and absorption. The low GI and blood glucose response of mango may be because of its fructose content (3.0%), acidity content (malic, citric and tartaric) and its phytic acid content (0.03%). Furthermore, starch, which is a possible factor contributing to low GI, is present in chico (0.8%) and mango (0.3%). Pineapple and papaya, the test fruits that elicited higher blood glucose responses and GI, have much lower fiber contents, less acids and contain glucose and sucrose sugars.

  19. Specificity of noninvasive blood glucose sensing using optical coherence tomography technique: a pilot study.

    Science.gov (United States)

    Larin, Kirill V; Motamedi, Massoud; Ashitkov, Taras V; Esenaliev, Rinat O

    2003-05-21

    Noninvasive monitoring of blood glucose concentration in diabetic patients would significantly reduce complications and mortality associated with this disease. In this paper, we experimentally and theoretically studied specificity of noninvasive blood glucose monitoring with the optical coherence tomography (OCT) technique. OCT images and signals were obtained from skin of Yucatan micropigs and New Zealand rabbits. Obtained results demonstrate that: (1) several body osmolytes may change the refractive index mismatch between the interstitial fluid (ISF) and scattering centres in tissue, however the effect of the glucose is approximately one to two orders of magnitude higher; (2) an increase of the ISF glucose concentration in the physiological range (3-30 mM) may decrease the scattering coefficient by 0.22% mM(-1) due to cell volume change; (3) stability of the OCT signal slope is dependent on tissue heterogeneity and motion artefacts; and (4) moderate skin temperature fluctuations (+/- 1 degree C) do not decrease accuracy and specificity of the OCT-based glucose sensor, however substantial skin heating or cooling (several degrees C) significantly change the OCT signal slope. These results suggest that the OCT technique may provide blood glucose concentration monitoring with sufficient specificity under normal physiological conditions.

  20. Blood Glucose Prediction Algorithms for Hypoglycemic and/or Hyperglycemic Alerts

    Directory of Open Access Journals (Sweden)

    C. Gireesh

    2012-09-01

    Full Text Available Continuous glucose monitoring (CGM sensors able to monitor blood glucose concentration continuously (i.e. with a reading every 1-5 min for several days (up to 7 consecutive days, entered clinical research. The availability of continuous glucose monitoring (CGM sensors allows development of new strategies for the treatment of diabetes. CGM sensors are of two types, noninvasive (NI-CGM or minimally-invasive (MI-CGM. Irrespective of the type, CGM sensors can become smart by providing them with algorithms able to generate alerts, say, 20-30 min ahead of time, when glucose concentration is predicted to exceed the normal range thresholds (70-180 mg/dL. Such alerts would allow diabetes patients to take precautionary measures to prevent hypo/hyperglycemia. In this paper we review blood glucose prediction algorithms such as first-order autoregressive( AR(1 , Kalman Filtering and Feed Forward Neural Network. All these algorithms have demonstrated that blood glucose can be predicted ahead in time.

  1. Path modelling of antecedent of diabetes mellitus on blood glucose measurements

    Science.gov (United States)

    Latif, Humaira'Abdul; Hamid, Mohd Rashid Ab; Azizan, Nor Azlinna; Jemain, Abdul Aziz

    2017-05-01

    Diabetes Mellitus (DM) is one of the non-communicable diseases and public health problems facing the worldwide population that includes Malaysia. Hitherto, the prevalence of DM becomes worsening with an estimated of 3.4 million Malaysians are diabetes sufferers and expectedly increasing year by year. Thus, this study is of great importance by regressing the medical factors that affect the blood glucose level using structural equation modelling (SEM). The SEM with partial least squares (PLS) estimation was applied to a secondary data of 644 respondents, aged ≥ 18 years in Malaysia. The data were collected in 2011 by Ministry of Health Malaysia (MOH). The variables under study are blood glucose level, cholesterol level (CL), systolic blood pressure (SBP), diastolic blood pressure (DBP), waist circumference (WC) and body mass index (BMI). From the modelling analysis, it showed that the cholesterol level (CL), systolic blood pressure (SBP) and waist circumference (WC) showed a positive significant relationship p diabetes mellitus among adults.

  2. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuici; Kuwabara, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine) (and others)

    1989-11-01

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author).

  3. Research of transmissive near infrared spectroscopy for non-invasive blood glucose measurement

    Science.gov (United States)

    Yang, Wenming; Liao, Ningfang; Li, Yasheng; Shao, Liwei; Huang, Dehuang

    2016-10-01

    Near infrared (NIR) has prospectively applied in non-invasive blood glucose measurement due to glucose absorption among the 1.0-2.5m spectral bands. However, this significant technology is hard to be developed because of other blood components and low signal-to-noise ratio (SNR). In this work, we presented a non-invasive glucose measurement system using Fourier transform spectrometer which will work in fingertips or other human body tissues. A refrigerated InGaAs detector with high quantum efficiency performing well in the range of 1.0-1.7μm wavelength is used to acquire transmissive radiation. Preliminary experiment investigations were set up to test glucose levels of aqueous solutions with different concentrations. The analytical modeling of the interferogram data is based on arithmetic Fourier transform and supported by the curvilineal characterization. Experimental results show the variation of light intensity among different glucose concentrations and emphasize the obvious absorption of glucose in NIR wave-range. This study confirms the suitability that NIR can be developed in non-invasive glucose measurement.

  4. [Achievement of the noninvasive measurement for human blood glucose with NIR diffusion reflectance spectrum method].

    Science.gov (United States)

    Zhang, Hong-yan; Ding, Dong; Song, Li-qiang; Gu, Lin-na; Yang, Peng; Tang, Yu-guo

    2005-06-01

    The noninvasive measurement of human blood glucose was achieved with NIR diffusion reflectance spectrum method. The thumb fingertip NIR diffusion reflectance spectra of six different age healthy volunteers were collected using Nexus-870 and its NIR fiber port smart accessory. The test was implemented with changing the blood glucose concentration for the limosis and satiation of every volunteer. The calibration model was set up using PLS method with the smoothing, baseline correction and first derivatives pretreatment spectrum in the 7500-8500 cm(-1) region for single volunteer, the same age combination and that of different age. When the spectrum was obtained, the actual blood glucose value of every spectrun sample was demarcated using ultraviolet spectrophotometer. The correlation between the calibration value and true value for single volunteer is better than that for the combination of volunteers, the correlative coefficients are all over 0.90471, RMSECs are all less than 0.171.

  5. Control of blood glucose in type 2 diabetes without weight loss by modification of diet composition

    Directory of Open Access Journals (Sweden)

    Gannon Mary C

    2006-03-01

    Full Text Available Abstract Background Over the past several years our research group has taken a systematic, comprehensive approach to determining the effects on body function (hormonal and non-hormonal of varying the amounts and types of proteins, carbohydrates and fats in the diet. We have been particularly interested in the dietary management of type 2 diabetes. Our objective has been to develop a diet for people with type 2 diabetes that does not require weight loss, oral agents, or insulin, but that still controls the blood glucose concentration. Our overall goal is to enable the person with type 2 diabetes to control their blood glucose by adjustment in the composition rather than the amount of food in their diet. Methods This paper is a brief summary and review of our recent diet-related research, and the rationale used in the development of diets that potentially are useful in the treatment of diabetes. Results We determined that, of the carbohydrates present in the diet, absorbed glucose is largely responsible for the food-induced increase in blood glucose concentration. We also determined that dietary protein increases insulin secretion and lowers blood glucose. Fat does not significantly affect blood glucose, but can affect insulin secretion and modify the absorption of carbohydrates. Based on these data, we tested the efficacy of diets with various protein:carbohydrate:fat ratios for 5 weeks on blood glucose control in people with untreated type 2 diabetes. The results were compared to those obtained in the same subjects after 5 weeks on a control diet with a protein:carbohydrate:fat ratio of 15:55:30. A 30:40:30 ratio diet resulted in a moderate but significant decrease in 24-hour integrated glucose area and % total glycohemoglobin (%tGHb. A 30:20:50 ratio diet resulted in a 38% decrease in 24-hour glucose area, a reduction in fasting glucose to near normal and a decrease in %tGHb from 9.8% to 7.6%. The response to a 30:30:40 ratio diet was similar

  6. Relationship of endothelial nitric oxide synthase gene polymorphism with blood pressure,lipid profile and blood glucose level

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    To study the relationship of the polymorphism of endothelial nitric oxide synthase(eNOS)gene and blood pressure,lipid profiles and blood glucose level.By using PCR-RFLP,the eNOS Glu298Asp gene polymorphism was detected in 184 patients with essential hypertension and 196 matched healthy individuals with normal blood pressure.Taking into account eNOS Glu298Asp polymorphisms,the relationship of blood pressure with triglycerides(TG),total cholesterol(TC),high density lipoprotein(HDL),low density lipoprotein(LDL)and blood glucose level was analyzed.The distribution of eNOS Glu298Asp polymorphism had no significant difference between different blood pressure groups and gender groups,but there was a significant difference between different age groups,diastolic blood pressure groups or BMI groups(P<0.05).Asp/Asp genotype significantly increased the risk of hypertension in individuals with serum TC above 5.4 mmol/L(P=0.03,OR=2.65).eNOSGlu298Asp polymorphism and serum lipid could synergistically modulate the blood pressure,eNOS Asp/Asp genotype could significantly increase the risk of hypertension in individuals with serum TC over 5.4 mmol/L,eNOS Glu298Asp in combination with serum TC could be used to predict the risk of hypertension.

  7. Magnesium enhances exercise performance via increasing glucose availability in the blood, muscle, and brain during exercise.

    Directory of Open Access Journals (Sweden)

    Hsuan-Ying Chen

    Full Text Available Glucose mobilization and utilization in the periphery and central nervous system are important during exercise and are responsible for exercise efficacy. Magnesium (Mg is involved in energy production and plays a role in exercise performance. This study aimed to explore the effects of Mg on the dynamic changes in glucose and lactate levels in the muscle, blood and brain of exercising rats using a combination of auto-blood sampling and microdialysis. Sprague-Dawley rats were pretreated with saline or magnesium sulfate (MgSO4, 90 mg/kg, i.p. 30 min before treadmill exercise (20 m/min for 60 min. Our results indicated that the muscle, blood, and brain glucose levels immediately increased during exercise, and then gradually decreased to near basal levels in the recovery periods of both groups. These glucose levels were significantly enhanced to approximately two-fold (P<0.05 in the Mg group. Lactate levels in the muscle, blood, and brain rapidly and significantly increased in both groups during exercise, and brain lactate levels in the Mg group further elevated (P<0.05 than those in the control group during exercise. Lactate levels significantly decreased after exercise in both groups. In conclusion, Mg enhanced glucose availability in the peripheral and central systems, and increased lactate clearance in the muscle during exercise.

  8. Pinitol from soybeans reduces postprandial blood glucose in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Kang, Min-Jung; Kim, Jung-In; Yoon, Sang-Yeon; Kim, Jae Cherl; Cha, In-June

    2006-01-01

    The effect of 3-O-methyl-D-chiro-inositol (D-pinitol), purified from soybean, on the postprandial blood glucose response in patients with type 2 diabetes mellitus was examined. Fifteen Korean subjects with type 2 diabetes mellitus (seven men, eight women; 60.3 +/- 3.1 years old) ingested cooked white rice containing 50 g of available carbohydrate with or without prior ingestion of soy pinitol. Pinitol was given either as a 1.2 g dose at 0, 60, 120, or 180 minutes prior to rice ingestion, or as a 0.6 g dose at 60 minutes prior to rice ingestion. Capillary blood glucose levels were monitored for 4 hours after rice consumption. The ingestion of 1.2 g of pinitol 60 minutes prior to rice consumption controlled postprandial capillary blood glucose most effectively, significantly diminishing the postprandial increase in plasma glucose levels measured at 90 and 120 minutes after rice consumption (P pinitol and rice was significantly lower than that for subjects who consumed only rice (P pinitol had no apparent effect on postprandial insulin levels. Therefore, soybean-derived pinitol may be useful in controlling postprandial increases in blood glucose in patients with type 2 diabetes.

  9. Remifentanil Prevents Increases of Blood Glucose and Lactate Levels during Cardiopulmonary Bypass in Pediatric Cardiac Surgery

    Science.gov (United States)

    Chaki, Tomohiro; Nawa, Yuko; Tamashiro, Keishi; Mizuno, Eri; Hirata, Naoyuki; Yamakage, Michiaki

    2017-01-01

    Introduction: Cardiopulmonary bypass (CPB) can cause stress response that increases levels of cytokine and catecholamine in plasma, resulting in hyperglycemia. In adults, it has been demonstrated that remifentanil infusion during CPB could prevent increases of cytokine, catecholamine, and blood glucose levels, but such effects of remifentanil in children have not been elucidated. Aim: In this study, we investigated the preventive effects of remifentanil on blood glucose and lactate levels during CPB in children. Materials and Methods: This retrospective study included children who underwent ventricular septal defect or atrial septal defect closure. Data for patients who did not receive, during CPB period, remifentanil infusion (non-Remi group) and patients who received remifentanil infusion at 0.5 μg/kg/min (Remi group) during CPB were used for analysis. Primary outcomes were lactate and blood glucose levels just before and after CPB. Data are presented as medians and interquartile ranges. Data were analyzed by the Mann–Whitney U-test and Chi-square test. A P < 0.05 was considered statistically significant. Results: During CPB, 13 and 11 patients were allocated into Remi and non-Remi groups, respectively. Pre-CPB lactate and blood glucose levels were not significantly different between the two groups, but post-CPB lactate and blood glucose levels in the Remi group were significantly lower than that in the non-Remi group. Conclusion: 0.5 μg/kg/min remifentanil infusion during CPB suppresses the increases of blood glucose and lactate levels in children. PMID:28074792

  10. Relationship among brain and blood glucose levels and spontaneous and glucoprivic feeding.

    Science.gov (United States)

    Dunn-Meynell, Ambrose A; Sanders, Nicole M; Compton, Douglas; Becker, Thomas C; Eiki, Jun-ichi; Zhang, Bei B; Levin, Barry E

    2009-05-27

    Although several studies implicate small declines in blood glucose levels as stimulus for spontaneous meal initiation, no mechanism is known for how these dips might initiate feeding. To assess the role of ventromedial hypothalamus (VMH) (arcuate plus ventromedial nucleus) glucosensing neurons as potential mediators of spontaneous and glucoprivic feeding, meal patterns were observed, and blood and VMH microdialysis fluid were sampled in 15 rats every 10 min for 3.5 h after dark onset and 2 h after insulin (5 U/kg, i.v.) infusion. Blood glucose levels declined by 11% beginning approximately 5 min before 65% of all spontaneous meals, with no fall in VMH levels. After insulin, blood and VMH glucose reached nadirs by 30-40 min, and the same rats ate 60% faster and spent 84% more time eating during the ensuing hypoglycemia. Although 83% of first hypoglycemic meals were preceded by 5 min dips in VMH (but not blood) glucose levels, neither blood nor VMH levels declined before second meals, suggesting that low glucose, rather than changing levels, was the stimulus for glucoprivic meals. Furthermore, altering VMH glucosensing by raising or lowering glucokinase (GK) activity failed to affect spontaneous feeding, body or adipose weights, or glucose tolerance. However, chronic depletion by 26-70% of VMH GK mRNA reduced glucoprivic feeding. Thus, although VMH glucosensing does not appear to be involved in either spontaneous feeding or long-term body-weight regulation, it does participate in glucoprivic feeding, similar to its role in the counter-regulatory neurohumoral responses to glucoprivation.

  11. Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer.

    Science.gov (United States)

    Gu, Chunmei; Lan, Tian; Shi, Hanchang; Lu, Yi

    2015-08-04

    Melamine detection in milk and other foods has attracted much attention since the discovery that melamine-adulterated food causes severe kidney damage. Although many methods have been developed to detect melamine, few methods can provide quantitative results using an affordable and portable device that is suitable for home use or field application. To achieve this goal, we herein report the first in vitro selection of a melamine responsive aptamer using a structure-switching method. A personal glucose meter (PGM) based melamine sensor was designed and subsequently tested using the newly isolated aptamer. Conversion of melamine concentration to glucose amount was achieved by including an invertase-conjugated DNA that is complementary to part of the aptamer. Melamine binding triggers the release of the invertase-DNA conjugate, which hydrolyzes sucrose into glucose. The glucose produced is then measured directly using an off-the-shelf PGM. The described sensor shows high selectivity for melamine against several closely related melamine analogues, such as cyanuric acid, ammeline, and ammelide, and has low detection limits of 0.33 μM (or 41.1 ppb) in buffer and 0.53 μM (or 67.5 ppb) in 80% whole milk without any pretreatment. The detection limits meet the threshold of 2.5 ppm for non-infant-formula products and 1 ppm for melamine in infant milk products as defined by the U.S. Food and Drug Administration (FDA). In addition to the PGM sensor demonstrated here, the same aptamer can be converted into other types of sensors with different signal outputs, allowing portable detection of melamine under a variety of conditions.

  12. A Post-Marketing Surveillance Study to Evaluate Performance of the EXIMO™ Blood Glucose Monitoring System.

    Science.gov (United States)

    Chandnani, Sonia R; Ramakrishna, C D; Dave, Bhargav A; Kothavade, Pankaj S; Thakkar, Ashok S

    2017-05-01

    The performance of Blood Glucose Monitoring System (BGMS) is critical as the information provided by the system guide the patient or health care professional in making treatment decisions. However, besides evaluating accuracy of the BGMS in laboratory setting, it is equally important that the intended users (healthcare professionals and patients) should be able to achieve blood glucose measurements with similar level of high accuracy. To assess the performance of EXIMO™ (Meril Diagnostics Pvt. Ltd., Vapi, Gujarat, India) BGMS as per International Organization for Standardization (ISO) 15197:2013 section 8 user performance criteria. This was a non-randomized and post-marketing study conducted at a tertiary care centre of India. A total of 1005 patients with diabetes themselves performed fingertip blood glucose measurement using EXIMO™ BGMS. Immediately after capillary blood glucose measurement using the blood glucose monitoring system, venous blood sample from each patient was obtained by a trained technician which was assessed by reference laboratory method- Cobas Integra 400 plus (Roche Instrument Centre, Rotkreuz, Switzerland). All the blood glucose measurements assessed by EXIMO™ were compared with laboratory results. Performance of the system was assessed as per ISO 15197:2013 criteria using Bland-Altman plot, Parkes-Consensus Error Grid (CEG) and Surveillance Error Grid analyses (SEG). A total of 1005 patients participated in the study. Average age of the patients was 44.93±14.65 years. Evaluation of capillary fingertip blood glucose measurements demonstrated that 95.82% measurements fulfilled ISO 15197:2013 section 8 user performance criteria. All the results lie within clinically non-critical zones; Zone A (99.47%; n=1000) and Zone B (0.53%; n=05) of the CEG analysis. As per SEG analysis, majority of the results fell within "no-risk" zone (risk score 0 to 0.5; 90.42%). The result of the study confirmed that intended users are able to obtain accurate

  13. Lanthanides' enhancing absorption of insulin and reduction of blood glucose of rat by pulmonary administration

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    To explore the possibility of lanthanides as the enhancer of insulin absorption, the promoting effects of lanthanide ions on the absorption of intrapulmonary delivered insulin and reduction of blood glucose were investigated by means of two approaches, preadministration and coadministration of lanthanide ions with insulin. The results indicate that, compared with the results of those given insulin only, lanthanide ions can effectively enhance the level of insulin and the reduction of glucose level in blood. These effects are dependent on lanthanide species and their concentrations. The mechanism was discussed.

  14. Comparison of glucose determinations on blood samples collected in three types of tubes.

    Science.gov (United States)

    Li, Geling; Cabanero, Michael; Wang, Zhenglong; Wang, Huiying; Huang, Tao; Alexis, Herol; Eid, Ikram; Muth, Gilad; Pincus, Matthew R

    2013-01-01

    Because of the metabolism of serum glucose in collection tubes containing blood samples, serum glucose levels may be found to decrease over time. Several types of collection tubes have been designed to, at least partially, block glucose metabolism by red blood cells in blood collection tubes that may not be analyzed immediately after blood collection. These include red-top collection tubes with serum separator, grey-top tubes with a fluoride glycolysis inhibitor, and heparin-containing green-top tubes which prevent clot formation. As part of a quality assurance project, we investigated whether glucose levels differed in the three tube types from each of 18 volunteers on a prolonged standing of 4 hours. We then determined the glucose concentrations of all three tubes from each of the 18 volunteers. We used refrigerated samples over a five-day period to determine if the initial values were reproducible. Surprisingly, after standing for four hours at room temperature, we found that the glucose levels in the three tubes from each volunteer were statistically indistinguishable from one another using the two-tailed paired t-test. Also, a linear regression analysis showed that the values of glucose for the three pairs of two tube types were closely correlated with one another, with correlation coefficients of >0.97, slopes close to 1, and Y-intercepts close to 0. These results suggest that blood collection in any of these tubes will render similar values for serum glucose even after standing for four hours. The tubes were then refrigerated at 4°C and re-analyzed after another six hours and then once per day for the next four days. Beginning at the first day at the six-hour determination, the glucose levels in the red- and grey-top tubes were statistically indistinguishable from one another but not in the red- and green-top tubes and in the grey- and green-top tubes. This was due to a steady decrease in the glucose levels in the green-top tubes. The glucose levels in the

  15. PSECMAC intelligent insulin schedule for diabetic blood glucose management under nonmeal announcement.

    Science.gov (United States)

    Teddy, S D; Quek, C; Lai, E M-K; Cinar, A

    2010-03-01

    Therapeutically, the closed-loop blood glucose-insulin regulation paradigm via a controllable insulin pump offers a potential solution to the management of diabetes. However, the development of such a closed-loop regulatory system to date has been hampered by two main issues: 1) the limited knowledge on the complex human physiological process of glucose-insulin metabolism that prevents a precise modeling of the biological blood glucose control loop; and 2) the vast metabolic biodiversity of the diabetic population due to varying exogneous and endogenous disturbances such as food intake, exercise, stress, and hormonal factors, etc. In addition, current attempts of closed-loop glucose regulatory techniques generally require some form of prior meal announcement and this constitutes a severe limitation to the applicability of such systems. In this paper, we present a novel intelligent insulin schedule based on the pseudo self-evolving cerebellar model articulation controller (PSECMAC) associative learning memory model that emulates the healthy human insulin response to food ingestion. The proposed PSECMAC intelligent insulin schedule requires no prior meal announcement and delivers the necessary insulin dosage based only on the observed blood glucose fluctuations. Using a simulated healthy subject, the proposed PSECMAC insulin schedule is demonstrated to be able to accurately capture the complex human glucose-insulin dynamics and robustly addresses the intraperson metabolic variability. Subsequently, the PSECMAC intelligent insulin schedule is employed on a group of type-1 diabetic patients to regulate their impaired blood glucose levels. Preliminary simulation results are highly encouraging. The work reported in this paper represents a major paradigm shift in the management of diabetes where patient compliance is poor and the need for prior meal announcement under current treatment regimes poses a significant challenge to an active lifestyle.

  16. Low perfusion index affects the difference in glucose level between capillary and venous blood

    Directory of Open Access Journals (Sweden)

    Acar N

    2014-11-01

    Full Text Available Nurdan Acar,1 Hamit Ozcelik,1 Arif Alper Cevik,1 Engin Ozakin,1 Goknur Yorulmaz,2 Nur Kebapci,2 Ugur Bilge,3 Muzaffer Bilgin4 1Emergency Department, 2Endocrinology Department, 3Family Medicine Department, 4Biostatistics Department, Medical School, Eskisehir Osmangazi University, Eskisehir, Turkey Aim: In emergency cases, finger stick testing is primarily used to check the blood glucose value of patients since it takes longer to obtain the venous value. In critical patients, under conditions that cause an increase in metabolic state and level of stress, there occurs considerable difference in glucose levels between capillary and venous measurements. This study aimed to investigate the comparability of capillary and venous glucose values, according to the perfusion index level obtained with the Masimo Radical-7® device, in critical patients aged 18 years and over.Method: We conducted this prospective and observational study in the emergency department of the Eskisehir Osmangazi University hospital between November 3, 2008 and February 2, 2009.Results: The blood glucose of 300 critical patients was checked by finger stick in the emergency unit. The participants with normal vital signs had perfusion index between 0 and 5; the results obtained by the two methods were more consistent for perfusion index values of 6 and over. The results were most consistent in aged participants with normal vital sign findings and low perfusion index and in young patients with high perfusion index. In the cases where at least one of the vital signs was abnormal, the glucose values obtained by the two methods were more consistent when the perfusion index was 6 or over. In this group, independently from the perfusion index value, the consistency was higher in younger patients compared with aged patients.Conclusion: In the emergency department, perfusion index value measured by Masimo Radical-7 and capillary blood glucose levels can serve in blood sugar management in

  17. Classification of diabetes and measurement of blood glucose concentration noninvasively using near infrared spectroscopy

    Science.gov (United States)

    Li, Zhe; Li, Gang; Yan, Wen-Juan; Lin, Ling

    2014-11-01

    Developing noninvasive blood glucose monitoring method is an to immense need to alleviate the pain and suffering of diabetics associated with the frequent pricking of skin for taking blood sample. A hybrid algorithm for multivariate calibration is proposed to improve the prediction performance of classification of diabetes and measurement of blood glucose concentration by near infrared (NIR) spectroscopy noninvasively. The algorithm is based on wavelet prism modified uninformative variable elimination approach (WP-mUVE) combined with least squares support vector machine (LSSVM), named as WP-mUVE-LSSVM. The method is successfully applied to diabetic classification experiment (in vivo) and blood glucose concentration measurement experiment (in vivo) respectively. Human tongue is selected as the measuring site in this study. To evaluate effectiveness of pretreatment method and quality of calibration models, several usually used pretreatment methods and kernel functions of LSSVM are introduced comparing with our method. Higher quality data is obtained by our pretreatment method owing to the elimination of varying background and noise of spectra data simultaneously. Better prediction accuracy and adaptability are obtained by LSSVM model with radial basis kernel function. The results indicate that WP-mUVE-LSSVM holds promise for the classification of diabetes and measurement of blood glucose concentration noninvasively based on human tongue using NIR spectroscopy.

  18. Blood optical properties at various glucose level values in THz frequency range

    Science.gov (United States)

    Gusev, S. I.; Borovkova, M. A.; Strepitov, M. A.; Khodzitsky, M. K.

    2015-07-01

    The number of diabetics is rapidly growing every day in all parts of the world. By the year 2010, the number of patients suffering from diabetes had amounted to more than 230 million people, which is estimated as 3.5% of the whole world adult population [1]. According to expert forecasts, this number is projected to double by the year 2025, which is going to be 7% of whole Earth population. It was calculated that every 10 seconds someone in the world dies due to diabetes and its complications, which is 3 million people per year. The average life expectancy of children with diabetes is less than 28.3 years of onset. Diabetes is considered to be the fourth most common cause of death in industrialized countries. Vascular complications due to diabetes cause early disability and high mortality. Mortality from heart diseases and strokes is 2-3 times more likely for patients suffering from diabetes, whereas blindness, nephropathy and lower limbs gangrene happen respectively 10, 12-15 times, and almost 20 times more often for diabetics than general population. The number and strength of complications depend directly on the blood glucose level control quality. At the moment, the blood glucose level measurements are performed by glucometers [2,3]. This method requires that a patient makes a finger puncture for every measurement. About five punctures per day should be done for proper glucose monitoring, which is about 1,800 punctures per year. Besides, each measurement by glucometer requires a distinct test strip. Expenses for 1,800 test strips could be estimated as about 450 euros per year. It is also necessary to take into account that each puncture has a risk of blood poisoning. Using non-invasive techniques for glucose level control could reduce the amount of possible risky manipulations by 1800 per year. Moreover, it is worth mentioning that only eight of ten fingers are suitable for puncturing, and the constant skin damage which cannot be avoided is quite annoying for

  19. Lithium modulates the chronic stress-induced effect on blood glucose level of male rats

    Directory of Open Access Journals (Sweden)

    Popović Nataša

    2010-01-01

    Full Text Available In the present study we examined gross changes in the mass of whole adrenal glands and that of the adrenal cortex, as well as the serum corticosterone and glucose level of mature male Wistar rats subjected to three different treatments: animals subjected to chronic restraint-stress, animals injected with lithium (Li and chronically stressed rats treated with Li. Under all three conditions we observed hypertrophy of whole adrenals, as well as the adrenal cortices. Chronic restraint stress, solely or in combination with Li treatment, significantly elevated the corticosterone level, but did not change the blood glucose level. Animals treated only with Li exhibited an elevated serum corticosterone level and blood glucose level. The aim of our study was to investigate the modulation of the chronic stress-induced effect on the blood glucose level by lithium, as a possible mechanism of avoiding the damage caused by chronic stress. Our results showed that lithium is an agent of choice which may help to reduce stress-elevated corticosterone and replenish exhausted glucose storages in an organism.

  20. Effects on cognitive performance of modulating the postprandial blood glucose profile at breakfast.

    Science.gov (United States)

    Nilsson, A; Radeborg, K; Björck, I

    2012-09-01

    Considering the importance of glucose as a brain substrate, the postprandial rate of glucose delivery to the blood could be expected to affect cognitive functions. The purpose was to evaluate to what extent the rate of glucose absorption affected measures of cognitive performance in the postprandial period. In addition, cognitive performance was evaluated in relation to individual glucoregulation. A white wheat bread (WWB) enriched with guar gum (G-WWB) with the capacity to produce a low but sustained blood glucose net increment was developed. The G-WWB was evaluated in the postprandial period after breakfast with respect to effects on cognitive function (working memory and selective attention (SA)) in 40 healthy adults (49-71 years, body mass index 20-29 kg/m(2)), using a high glycaemic index WWB for comparison in a randomised crossover design. The G-WWB improved outcome in the cognitive tests (SA test) in the later postprandial period (75-225 min) in comparison with the WWB (Pcognitive tests compared with subjects with worse glucoregulation (Pcognitive performance were observed with the G-WWB in the late postprandial period. The positive effect is suggested to emanate from improved insulin sensitivity, possibly in a combination with an enhanced neural energy supply. The results highlight the importance of carbohydrate foods that induces a low but sustained blood glucose profile in enhancing postprandial cognitive functions.

  1. Melatonin Signaling Controls the Daily Rhythm in Blood Glucose Levels Independent of Peripheral Clocks.

    Directory of Open Access Journals (Sweden)

    Sharon Owino

    Full Text Available Melatonin is rhythmically secreted by both the pineal gland and retina in a circadian fashion, with its peak synthesis occurring during the night. Once synthesized, melatonin exerts its effects by binding to two specific G-protein coupled receptors-melatonin receptor type 1(MT1 and melatonin receptor type 2(MT2. Recent studies suggest the involvement of MT1 and MT2 in the regulation of glucose homeostasis; however the ability of melatonin signaling to impart timing cues on glucose metabolism remains poorly understood. Here we report that the removal of MT1 or MT2 in mice abolishes the daily rhythm in blood glucose levels. Interestingly, removal of melatonin receptors produced small effects on the rhythmic expression patterns of clock genes within skeletal muscle, liver, and adipose tissue. Taken together, our data suggest that the loss of the daily rhythm in blood glucose observed in MT1(-/- and MT2(-/- mice does not occur as a consequence of 'disrupted' clocks within insulin sensitive tissues. Finally our results highlight a diurnal contribution of melatonin receptor signaling in the daily regulation of blood glucose levels.

  2. Glycemic index and postprandial blood glucose response to Japanese strawberry jam in normal adults.

    Science.gov (United States)

    Kurotobi, Tomoka; Fukuhara, Kimiaki; Inage, Hiroko; Kimura, Shuichi

    2010-01-01

    We investigated in 30 healthy adults the glycemic index (GI) of five strawberry jams made from various sugar compositions. The jam containing the highest ratio of glucose showed a high GI, while that containing a high ratio of fructose, a jam made from polydextrose, showed a low GI. There was a high correlation (r=0.969, p=0.006) between the GI and the predicted GI calculated from the sugar composition of the jams. Moreover, the influence on postprandial blood glucose response after an intake of only 20 g of jam and one slice of bread with 20 g jam was measured in 8 healthy adults. The blood glucose level after an intake of 20 g of the high GI jam containing the high glucose ratio was higher than that of other jams at 15 min, but there was no significant difference after 30 min. Regardless of whether the GI was low or high, differences in the jams were not observed in the postprandial blood glucose level or the area under the curve after eating either one slice of bread (60 g) or one slice of bread with less than 20 g of jam.

  3. Effect of training on the performance of blood glucose monitoring using a reagent strip (Glucoprofil).

    Science.gov (United States)

    Chantelau, E; Starostina, E G; Antsiferov, M B

    1990-11-01

    A relatively simple, new test-strip for blood-glucose monitoring, the Glucoprofil strip with a reaction-zone of film-foil, was evaluated by testing 100 different blood glucose concentrations between 2.1 and 29.7 mmol/l. The results were obtained visually before and after training to read the color changes of the strip according to the scale on the strip-container. Plasma glucose measurements with the Beckman Glucose-Analyzer were used for reference. The results show that the Glucoprofil-strip readings correlated well with the reference method (r = 0.97), thorough training provided. The mean deviation of the strip results was less than 1 mmol/l. Similar results were obtained using another blood glucose strip, the Haemoglukotest 20-800 R. Our study indicates that the performance of the Glucoprofil strip is satisfactory, and hence the strip may be useful for clinical purposes. Consistent with previous reports we could demonstrate that training improved the reading results of the Glucoprofil strip.

  4. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study

    Directory of Open Access Journals (Sweden)

    Satish Kumar

    2014-01-01

    Full Text Available Objectives: To study the correlation between blood glucose levels and salivary glucose levels in type 2 diabetic patients, to study the relationship between salivary glucose levels and oral candidal carriage in type 2 diabetic patients and to determine whether salivary glucose levels could be used as a noninvasive tool for the measurement of glycemic control in type 2 diabetics. Study Design: The study population consisted of three groups: Group 1 consisted of 30 controlled diabetics and Group 2 consisted of 30 uncontrolled diabetics based on their random nonfasting plasma glucose levels. Group 3 consisted of 30 healthy controls. Two milliliters of peripheral blood was collected for the estimation of random nonfasting plasma glucose levels and glycosylated hemoglobin (HbA1c. Unstimulated saliva was collected for the estimation of salivary glucose. Saliva was collected by the oral rinse technique for the estimation of candidal counts. Results: The salivary glucose levels were significantly higher in controlled and uncontrolled diabetics when compared with controls. The salivary candidal carriage was also significantly higher in uncontrolled diabetics when compared with controlled diabetics and nondiabetic controls. The salivary glucose levels showed a significant correlation with blood glucose levels, suggesting that salivary glucose levels can be used as a monitoring tool for predicting glycemic control in diabetic patients. Conclusion: The present study found that estimation of salivary glucose levels can be used as a noninvasive, painless technique for the measurement of diabetic status of a patient in a dental set up. Increased salivary glucose levels leads to increased oral candidal carriage; therefore, oral diagnosticians are advised to screen the diabetic patients for any oral fungal infections and further management.

  5. The Quantitative Relationship Between ISO 15197 Accuracy Criteria and Mean Absolute Relative Difference (MARD) in the Evaluation of Analytical Performance of Self-Monitoring of Blood Glucose (SMBG) Systems.

    Science.gov (United States)

    Pardo, Scott; Simmons, David A

    2016-09-01

    The relationship between International Organization for Standardization (ISO) accuracy criteria and mean absolute relative difference (MARD), 2 methods for assessing the accuracy of blood glucose meters, is complex. While lower MARD values are generally better than higher MARD values, it is not possible to define a particular MARD value that ensures a blood glucose meter will satisfy the ISO accuracy criteria. The MARD value that ensures passing the ISO accuracy test can be described only as a probabilistic range. In this work, a Bayesian model is presented to represent the relationship between ISO accuracy criteria and MARD. Under the assumptions made in this work, there is nearly a 100% chance of satisfying ISO 15197:2013 accuracy requirements if the MARD value is between 3.25% and 5.25%.

  6. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy.

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2012-01-31

    BACKGROUND: To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. METHODS: Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. RESULTS: Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. CONCLUSION: During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  7. Early blood glucose profile and neurodevelopmental outcome at two years in neonatal hypoxic-ischaemic encephalopathy

    LENUS (Irish Health Repository)

    Nadeem, Montasser

    2011-02-04

    Abstract Background To examine the blood glucose profile and the relationship between blood glucose levels and neurodevelopmental outcome in term infants with hypoxic-ischaemic encephalopathy. Methods Blood glucose values within 72 hours of birth were collected from 52 term infants with hypoxic-ischaemic encephalopathy. Hypoglycaemia [< 46.8 mg\\/dL (2.6 mmol\\/L)] and hyperglycaemia [> 150 mg\\/dL (8.3 mmol\\/L)] were correlated to neurodevelopmental outcome at 24 months of age. Results Four fifths of the 468 blood samples were in the normoglycaemic range (392\\/468:83.8%). Of the remaining 76 samples, 51.3% were in the hypoglycaemic range and (48.7%) were hyperglycaemic. A quarter of the hypoglycaemic samples (28.2%:11\\/39) and a third of the hyperglycaemic samples (32.4%:12\\/37) were recorded within the first 30 minutes of life. Mean (SD) blood glucose values did not differ between infants with normal and abnormal outcomes [4.89(2.28) mmol\\/L and 5.02(2.35) mmol\\/L, p value = 0.15] respectively. In term infants with hypoxic-ischaemic encephalopathy, early hypoglycaemia (between 0-6 hours of life) was associated with adverse outcome at 24 months of age [OR = 5.8, CI = 1.04-32)]. On multivariate analysis to adjust for grade of HIE this association was not statistically significant. Late hypoglycaemia (6-72 hours of life) was not associated with abnormal outcome [OR = 0.22, CI (0.04-1.14)]. The occurrence of hyperglycaemia was not associated with adverse outcome. Conclusion During the first 72 hours of life, blood glucose profile in infants with hypoxic-ischaemic encephalopathy varies widely despite a management protocol. Early hypoglycaemia (0-6 hours of life) was associated with severe HIE, and thereby; adverse outcome.

  8. Determination of time delay between blood and interstitial adipose tissue glucose concentration change by microdialysis in healthy volunteers

    NARCIS (Netherlands)

    Wientjes, KJC; Schoonen, AJM

    2001-01-01

    For the development and use of subcutaneous glucose sensors it is important to know the time lag between changes in blood glucose and subcutaneous interstitial glucose concentration. To determine the time lag we inserted a microdialysis probe into the abdominal subcutaneous adipose tissue of healthy

  9. Feasibility of non-invasive optical blood-glucose detection using overtone circular dichroism

    CERN Document Server

    Hokr, Brett H; Meng, Zhaokai; Petrov, Georgi I; Yakovlev, Vladislav V

    2016-01-01

    Diabetes is one of the most debilitating and costly diseases currently plaguing humanity. It is a leading cause of death and dismemberment in the world, and we know how to treat it. Accurate, continuous monitoring and control of blood glucose levels via insulin treatments are widely known to mitigate the majority of detrimental effects caused by the disease. The primary limitation of continuous glucose monitoring is patient non-compliance due to the unpleasant nature of "finger-stick" testing methods. This limitation can be largely, or even completely, removed by non-invasive testing methods. In this report, we demonstrate the vibrational overtone circular dichroism properties of glucose and analyze its use as a method of non-invasive glucose monitoring, capable of assuaging this trillion dollar scourge.

  10. Non-invasive blood glucose monitoring with Raman spectroscopy: prospects for device miniaturization

    Science.gov (United States)

    Wróbel, M. S.

    2016-01-01

    The number of patients with diabetes has reached over 350 million, and still continues to increase. The need for regular blood glucose monitoring sparks the interest in the development of modern detection technologies. One of those methods, which allows for noninvasive measurements, is Raman spectroscopy. The ability of infrared light to penetrate deep into tissues allows for obtaining measurements through the skin without its perforation. This paper presents the limitations and possibilities of non-invasive blood glucose monitoring with Raman spectroscopy. Especially focusing on the possibilities for device miniaturization. Such device incorporates a Raman spectrometer, a fiber-optical probe, and a computing device (microcontroller, smartphone, etc.) which calculates the glucose concentration using specialized algorithms. Simplification of device design, as well as turbidity correction technique and a new proposed method of synchronized detection are described.

  11. Association between whole blood mercury and glucose intolerance among adult Inuit in Greenland

    DEFF Research Database (Denmark)

    Jeppesen, Charlotte; Valera, Beatriz; Nielsen, Nina O

    2015-01-01

    OBJECTIVES: The Arctic diet is partly constituted by traditional food characterized by top predator animals such as whales, walrus, and seals with high mercury content. Mercury exposure has been associated with glucose intolerance in Western populations. We studied the association between whole...... insulin sensitivity by ISI0,120., and relative beta cell function by c-peptide/insulin ratio. We conducted adjusted linear- and logistic regression analyses. RESULTS: For an increase in whole blood mercury of 5µg/L we found a positive association with fasting glucose [% change=0.25 (95% CI: 0.20; 0.30); p...... between whole blood mercury and both impaired fasting glycemia and type 2 diabetes, no associations were found with measures of underlying disturbances in glucose homoeostasis....

  12. Blood Glucose Levels in Diabetic Patients Following Corticosteroid Injections into the Subacromial Space of the Shoulder

    Directory of Open Access Journals (Sweden)

    Alexander w. Aleem

    2017-09-01

    Full Text Available Background: Corticosteroid injections are used to treat a variety of orthopedic conditions with the goal of decreasingpain and inflammation. Administration of systemic or local corticosteroids risks temporarily increasing blood glucoselevels, especially diabetic patients. The purpose of this study is to quantify the effects of corticosteroid injections onblood glucose levels in diabetic patients with shoulder pathology.Methods: Diabetic patients who regularly monitored their blood glucose levels and were indicated for a subacromialcorticosteroid injection were included in this prospective investigation. The typical normal morning fasting glucoseand most recent hemoglobin A1c level was recorded for each patient. After injection, patients were contacted daily toconfirm their fasting morning glucose level for 10 days post-injection.Results: Seventeen consecutive patients were enrolled. Patients with hemoglobin A1c of

  13. Protective coating and hyperthermal atomic oxygen texturing of optical fibers used for blood glucose monitoring

    Science.gov (United States)

    Banks, Bruce A. (Inventor)

    2008-01-01

    Disclosed is a method of producing cones and pillars on polymethylmethacralate (PMMA) optical fibers for glucose monitoring. The method, in one embodiment, consists of using electron beam evaporation to deposit a non-contiguous thin film of aluminum on the distal ends of the PMMA fibers. The partial coverage of aluminum on the fibers is randomly, but rather uniformly distributed across the end of the optical fibers. After the aluminum deposition, the ends of the fibers are then exposed to hyperthermal atomic oxygen, which oxidizes the areas that are not protected by aluminum. The resulting PMMA fibers have a greatly increased surface area and the cones or pillars are sufficiently close together that the cellular components in blood are excluded from passing into the valleys between the cones and pillars. The optical fibers are then coated with appropriated surface chemistry so that they can optically sense the glucose level in the blood sample than that with conventional glucose monitoring.

  14. Evaluation of 2 portable ion-selective electrode meters for determining whole blood, plasma, urine, milk, and abomasal fluid potassium concentrations in dairy cattle.

    Science.gov (United States)

    Megahed, A A; Hiew, M W H; Grünberg, W; Constable, P D

    2016-09-01

    Two low-cost ion-selective electrode (ISE) handheld meters (CARDY C-131, LAQUAtwin B-731; Horiba Ltd., Albany, NY) have recently become available for measuring the potassium concentration ([K(+)]) in biological fluids. The primary objective of this study was to characterize the analytical performance of the ISE meters in measuring [K(+)] in bovine whole blood, plasma, urine, milk, and abomasal fluid. We completed 6 method comparison studies using 369 whole blood and plasma samples from 106 healthy periparturient Holstein-Friesian cows, 138 plasma samples from 27 periparturient Holstein-Friesian cows, 92 milk samples and 204 urine samples from 16 lactating Holstein-Friesian cows, and 94 abomasal fluid samples from 6 male Holstein-Friesian calves. Deming regression and Bland-Altman plots were used to characterize meter performance against reference methods (indirect ISE, Hitachi 911 and 917; inductively coupled plasma-optical emission spectroscopy). The CARDY ISE meter applied directly in plasma measured [K(+)] as being 7.3% lower than the indirect ISE reference method, consistent with the recommended adjustment of +7.5% when indirect ISE methods are used to analyze plasma. The LAQUAtwin ISE meter run in direct mode measured fat-free milk [K(+)] as being 3.6% lower than the indirect ISE reference method, consistent with a herd milk protein percentage of 3.4%. The LAQUAtwin ISE meter accurately measured abomasal fluid [K(+)] compared to the indirect ISE reference method. The LAQUAtwin ISE meter accurately measured urine [K(+)] compared to the indirect ISE reference method, but the median measured value for urine [K(+)] was 83% of the true value measured by inductively coupled plasma-optical emission spectroscopy. We conclude that the CARDY and LAQUAtwin ISE meters are practical, low-cost, rapid, accurate point-of-care instruments suitable for measuring [K(+)] in whole blood, plasma, milk, and abomasal fluid samples from cattle. Ion-selective electrode methodology is

  15. Bihormonal control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tárnik, Marían; Murgaš, Ján;

    2015-01-01

    This paper presents a bihormonal artificial pancreas (AP) for people with type 1 diabetes (T1D) designed to provide a safe blood glucose control with minimal use of glucagon. The control algorithm uses insulin as well as glucagon to prevent hyper- and hypoglycemia. We employ a novel prediction...

  16. Cinnamon intake lowers fasting blood glucose: an updated meta-analysis

    Science.gov (United States)

    OBJECTIVE – To determine if meta-analysis of recent clinical studies of cinnamon intake by people with Type II diabetes and/or prediabetes resulted in significant changes in fasting blood glucose. RESEARCH DESIGN AND METHODS -- Published clinical studies were identified using a literature search (P...

  17. Self-monitoring of blood glucose during pregnancy: indications and limitations

    Directory of Open Access Journals (Sweden)

    Negrato Carlos Antonio

    2012-12-01

    Full Text Available Abstract Self-monitoring of blood glucose (SMBG is an important tool to treat diabetes during pregnancy. However, proper implementation of SMBG in pregnant women requires understanding of its applications and limitations. This article reviews issues related to the implementation, efficacy, and accuracy of SMBG and discusses factors that can confound results of SMBG during pregnancy.

  18. Higher Blood Glucose within the Normal Range Is Associated with More Severe Strokes

    DEFF Research Database (Denmark)

    Martin, Rolf J; Ratan, Rajiv R; Reding, Michael J

    2012-01-01

    Background. Higher fasting blood glucose (FBG) concentrations in the hyperglycemic range are associated with more severe strokes. Whether this association also extends into patients with FBG in the normoglycemic range is unclear. We studied the association of stroke severity and FBG in normoglyce...

  19. Bihormonal model predictive control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tarnik, Marian; Murgas, Jan

    2014-01-01

    In this paper we present a bihormonal control system that controls blood glucose in people with type 1 diabetes (T1D). We use insulin together with glucagon to mitigate the negative effects of hyper- and hypoglycemia. The system consists of a Kalman filter, a micro-bolus insulin and glucagon...

  20. Blood Glucose Monitoring as a Teaching Tool for Endocrinology: A New Perspective

    Science.gov (United States)

    Moats, Robert K., II

    2009-01-01

    The education of new allied health professionals and nurses in proper endocrine evaluation and care has become critical in recent years, especially considering the greatly increased prevalence of diabetes in adults and children. The evaluation of blood glucose levels in human volunteers over time is a powerful teaching tool for endocrinology that…

  1. Comprehensive Experiment--Clinical Biochemistry: Determination of Blood Glucose and Triglycerides in Normal and Diabetic Rats

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a…

  2. The Solution of Modified Fractional Bergman’s Minimal Blood Glucose-Insulin Model

    Directory of Open Access Journals (Sweden)

    Badr S. Alkahtani

    2017-05-01

    Full Text Available In the present paper, we use analytical techniques to solve fractional nonlinear differential equations systems that arise in Bergman’s minimal model, used to describe blood glucose and insulin metabolism, after intravenous tolerance testing. We also discuss the stability and uniqueness of the solution.

  3. Comprehensive Experiment--Clinical Biochemistry: Determination of Blood Glucose and Triglycerides in Normal and Diabetic Rats

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a…

  4. Self-monitoring of blood glucose in tablet-treated type 2 diabetic patients (ZODIAC)

    NARCIS (Netherlands)

    Kleefstra, Nanno; Hortensius, J.; Logtenberg, Susan; Slingerland, R. J.; Groenier, K. H.; Houweling, S. T.; Gans, R. O. B.; van Ballegooie, E; Bilo, H. J. G.

    2010-01-01

    Background: Whether self-monitoring of blood glucose (SMBG) improves glycaemic control in patients with type 2 diabetes mellitus (T2DM) not using insulin is questionable. Our aim was to investigate the effects of SMBG in patients with T2DM who were in persistent moderate glycaemic control whilst not

  5. Effect of miglitol (BAY m-1099) on fasting blood glucose in type 2 diabetes mellitus

    NARCIS (Netherlands)

    Sels, J P; Kingma, P J; Wolffenbuttel, B H; Menheere, P P; Branolte, J H; Nieuwenhuijzen Kruseman, A C

    1994-01-01

    BACKGROUND: In type 2 diabetes mellitus, fasting blood glucose values are increased due to increased glycogenolysis and gluconeogenesis. As miglitol (BAY m-1099), an absorbable alpha-glucosidase inhibitor, can inhibit glycogenolysis, we investigated whether 200 mg miglitol ingested at bedtime could

  6. Monitoring of glucose levels in mouse blood with noninvasive optical methods

    Science.gov (United States)

    Ullah, H.; Ahmed, E.; Ikram, M.

    2014-02-01

    We report the quantification/monitoring of glucose levels in a blood sample using optical diffuse reflectance (ODR) underlying variations in optical parameters with a white light source (at peak wavelength ˜600 nm and range 450-850 nm) and in blood in vivo using M-mode optical coherence tomography (OCT) in terms of the translational diffusion coefficient (DT). In the ODR experiments, we have investigated two types of mono-dispersive particles, i.e. polystyrene microspheres (PMSs) with diameters of 1.4 μm (variable concentrations) and 2.6 μm (fixed concentration) in a water phantom by observing changes in the reduced scattering coefficient. We believe that these differences in optical properties will be helpful for the understanding and optimal use of laser applications in blood glucometry without piercing the skin. In the OCT experiments, this idea of glucose monitoring was applied on an in vivo normal mouse without injection of glucose intravenously to provide the threshold levels by envisioning/identifying a blood vessel by speckle variance (SV-OCT) using a dorsal skinfold mouse windows chamber model. We report an average value of translation decorrelation time τT = 41.18 ± 1.92 ms and DT = 8.90 × 10-14 m2 s-1 underlying the dynamic light scattering (DLS). Our results have a potential application in the quantification of higher glucose levels in vivo administrated intravenously.

  7. PREANALITIC AND INTERPRETATION BLOOD GLUCOSE FOR DIAGNOSE DIABETIC MELITUS

    Directory of Open Access Journals (Sweden)

    Ida Bagus Wayan Kardika

    2013-10-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Diabetes mellitus (DM is a metabolic disorder disease which has been characterised by chronic hyperglycemia as well as abnormalities in the metabolism of carbohydrates, fats and proteins caused by abnormalities of insulin secretion, insulin resistance or both. The Diagnoses of diabetes mellitus in addition based on the clinical aspects of which include anamnesis, physical examination and diagnoses is required in the form of investigations the laboratory examination. The simplest laboratory examination is the examination of blood sugar. The stages of preanalitic and the interpretation of results examination of the blood sugar is worth noting in order to obtain meaningful results so that a diagnosis of diabetes mellitus can be enforced and for monitoring treatment outcomes. /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  8. Tracking blood glucose and predicting prediabetes in Chinese children and adolescents: a prospective twin study.

    Directory of Open Access Journals (Sweden)

    Guoying Wang

    Full Text Available We examined the tracking of blood glucose, the development of prediabetes, and estimated their genetic contributions in a prospective, healthy, rural Chinese twin cohort. This report includes 1,766 subjects (998 males, 768 females aged 6-21 years at baseline who completed a 6-year follow-up study. Oral glucose tolerance test was performed for all subjects at both baseline and follow-up. We found that subjects with low fasting plasma glucose (FPG or 2 h post-load glucose (PG levels at baseline tended to remain at the low level at follow-up. Subjects in the top tertile of baseline plasma glucose tended to have a higher risk of developing prediabetes at follow-up compared to the low tertile: in males, 37.6% vs. 27.6% for FPG and 37.2% vs. 25.7% for 2hPG, respectively; in females, 31.0% vs. 15.4% for FPG and 28.9% vs. 15.1% for 2 h PG, respectively. Genetic factors explained 43% and 41% of the variance of FPG, and 72% and 47% for impaired fasting glucose for males and females, respectively; environmental factors substantially contribute to 2hPG status and impaired glucose tolerance. In conclusion, in this cohort of healthy rural Chinese children and adolescents, we demonstrated that both FPG and 2hPG tracked well and was a strong predictor of prediabetes. The high proportion of children with top tertile of blood glucose progressed to prediabetes, and the incidence of prediabetes has a male predominance. Genetic factors play more important role in fasting than postload status, most of which was explained by unique environmental factors.

  9. Impairment of brain endothelial glucose transporter by methamphetamine causes blood-brain barrier dysfunction

    Directory of Open Access Journals (Sweden)

    Murrin L Charles

    2011-03-01

    Full Text Available Abstract Background Methamphetamine (METH, an addictive psycho-stimulant drug with euphoric effect is known to cause neurotoxicity due to oxidative stress, dopamine accumulation and glial cell activation. Here we hypothesized that METH-induced interference of glucose uptake and transport at the endothelium can disrupt the energy requirement of the blood-brain barrier (BBB function and integrity. We undertake this study because there is no report of METH effects on glucose uptake and transport across the blood-brain barrier (BBB to date. Results In this study, we demonstrate that METH-induced disruption of glucose uptake by endothelium lead to BBB dysfunction. Our data indicate that a low concentration of METH (20 μM increased the expression of glucose transporter protein-1 (GLUT1 in primary human brain endothelial cell (hBEC, main component of BBB without affecting the glucose uptake. A high concentration of 200 μM of METH decreased both the glucose uptake and GLUT1 protein levels in hBEC culture. Transcription process appeared to regulate the changes in METH-induced GLUT1 expression. METH-induced decrease in GLUT1 protein level was associated with reduction in BBB tight junction protein occludin and zonula occludens-1. Functional assessment of the trans-endothelial electrical resistance of the cell monolayers and permeability of dye tracers in animal model validated the pharmacokinetics and molecular findings that inhibition of glucose uptake by GLUT1 inhibitor cytochalasin B (CB aggravated the METH-induced disruption of the BBB integrity. Application of acetyl-L-carnitine suppressed the effects of METH on glucose uptake and BBB function. Conclusion Our findings suggest that impairment of GLUT1 at the brain endothelium by METH may contribute to energy-associated disruption of tight junction assembly and loss of BBB integrity.

  10. Analysis on blood glucose excursions in well-controlled patients with type 2 diabetes mellitus

    Institute of Scientific and Technical Information of China (English)

    Deng Wuquan; Yu Qiongwu; Wang Fuhua; Ai Zhihua; Chen Bing

    2009-01-01

    Objective: To probe glycemic excursions in type 2 diabetic patients whose hemoglobin A1c (HbA1c) was kept ≤6.0%.Methods: Totally 36 cases with type 2 diabetes (T2DM) with HbA1c≤6.0% and 30 cases with normal glucose tolerance (NGT) from December 2005 to December 2007 in our department were subjected prospectively. Continuous glucose monitoring system (CGMS) was employed to record their continuous blood glucose level for 3 d. The blood glucose profiles including the mean blood glucose (MBG), standard differentiation (SD), mean amplitude of glycemic excursions (MAGE) and absolute means of daily differences (MODD) were analyzed. Results: T2DM group had obviously postprandial hyperglycemia, in about 2 h after meal, especially after breakfast. Fifty-two hypoglycemic episodes occurred during the monitoring period in T2DM groups, of which 73.1% (38 episodes) were absence of symptomatic hypoglycemia with the lowest value of blood glucose only 2.0 mmol/L. And 20 episodes took place during the day hours, while 32 episodes observed during the night hours. Compared with NGT groups, SD, MAGE and MODD were all significantly higher in T2DM groups. MBG was significantly correlated with HbA1c in T2DM groups, but SD, MAGE, NGE and MODD were all independent of HbA1c. MAGE was independent of MODD. Conclusion: The amplitude of glycemic excursions is higher in normol-controlled T2DM groups than the NGT groups.Thus ideally glycemic control is not only to make HbA1c reach standard, but also to lessen glycemic excursions and reduce hypoglycemia episodes.

  11. Using the first drop of blood for monitoring blood glucose values in critically ill patients: An observational study

    Science.gov (United States)

    Saini, Sunita; Kaur, Sukhpal; Das, Karobi; Saini, Vikas

    2016-01-01

    Context: Using the first drop or second drop of blood while measuring blood glucose (BG) values. Objective: The study was planned to compare the BG values from the first and second drops of blood. Research Settings: The study was conducted at the Main Intensive Care Unit, PGIMER, Chandigarh, India. Research Design: This study was a comparative study. Materials and Methods: Ninety patients aged 2–93 years were enrolled in this study. BG values from the first and second drops of blood were taken and compared. Statistical Analysis Used: Agreement between two drops was assessed using Bland–Altman analysis. A bias of <10 mg/dl was considered clinically acceptable. Linear regression of the mean difference (bias) with the BG readings was performed. Results: One thousand four hundred and seven pairs of BG readings were taken from the enrolled patients. BG values had a bias of 3.9 ± 14.9 mg/dl. Nearly 96.7% of BG readings were within the limits of agreement. The absolute difference between first and second drops of blood was calculated; nearly 75.4% of the readings had fallen between 0 and 10 mg/dl, i.e. clinically acceptable range. Conclusion: There is no compete concordance of values of blood glucose between the first and the second drops of blood; any of the drops can be used for measuring BG values as the difference is not statistically significant. However, if hands are visibly clean and to decrease the blood loss in the critically ill patients where the BG values are measured frequently, using the first drop of blood is advised. PMID:27994381

  12. The effect of food with different glycaemic index on the blood glucose level

    Directory of Open Access Journals (Sweden)

    Lenka Kouřimská

    2015-08-01

    Full Text Available Blood glucose levels are affected by many factors including the type of foods consumed, processing technology and cooking method. Hormone insulin lowers blood glucose to its constant level, while glucagon, growth hormone, adrenalin and glucocorticoids have the opposite effect. High steepness of the blood glucose level rise after meals may be unfavourable for the organism. Sugars are transferred into the blood at different speeds according to the type of food. Therefore the aim of this study was to confirm experimentally the effect of food on blood glucose levels in men and women of different ages. Two types of low, medium and high-glycaemic index (GI foods were given to 4 men and 4 women of different age (from 35 to 65 years. All volunteers were healthy, slightly overweight, and without any regular sporting activity. None of them had any idea about their daily carbohydrates consumption and what the term glycaemic index meant. The volunteers came to the GI determination fasted in the morning. Their rise in blood glucose level was monitored by glucometer before the meal and after 1 and 2 hours of the consumption of baked potatoes (GI 85, white bread bun (GI 70, boiled potatoes (GI 64, rye bread (GI 62, potato dumplings (GI 52 and white cooked spaghetti (GI 41. Fasting blood sugar levels of volunteers highly depended on their age (p <0.0001 and gender (p <0.0001. The blood glucose values increased with age and were higher in men than in women. Significant influence of food GI on blood glucose levels in both men and women in all the age categories was observed (p <0.0001. An interaction between age and gender was also statistically highly significant (p <0.0001. One hour after consuming food the blood glucose values were significantly different from the values of fasting (p = 0.0035. The differences of these values did not depend on the age (p = 0.0574 and sex (p = 0.8256 of volunteers, but there was a significant difference on the GI value of food

  13. Calibration Experiments Conducted for Noninvasive Blood Glucose Sensing Through the Eye

    Science.gov (United States)

    Ansari, Rafat R.; Bockle, Stefan; Suh, Kwang I.; Rovati, Luigi L.

    2004-01-01

    There are more than 16 million diabetics in the United States and more than 100 million worldwide. Diabetes can lead to severe complications over time such as blindness, renal and cardiovascular diseases, and peripheral neuropathy in the limbs. Poor blood circulation in diabetics can lead to gangrene and the subsequent amputation of extremities. In addition, this pathology is the fourth leading cause of death in the United States. The most effective way to manage diabetes is frequent blood glucose monitoring performed by the patients themselves. However, because of pain, inconvenience, and the fear of developing infections from finger-prick blood tests or implants, many patients monitor their blood glucose levels less frequently than is recommended by their physicians. Therefore, a noninvasive, painless, and convenient method to monitor blood glucose would greatly benefit diabetics. Likewise, detecting, preventing, and treating the untoward effects of prolonged space travel (e.g., a human mission to Mars) in real-time requires the development of noninvasive diagnostic technologies that are compact and powerful. As a "window to the body," the eye offers the opportunity to use light in various forms to detect ocular and systemic abnormalities long before clinical symptoms appear and to help develop preventative and therapeutic countermeasures early. The noninvasive feature of these technologies permits frequent repetition of tests, enabling an evaluation of the response to therapy.

  14. Evaluation of a blood glucose monitoring system with automatic high- and low-pattern recognition software in insulin-using patients: pattern detection and patient-reported insights.

    Science.gov (United States)

    Grady, Mike; Campbell, Denise; MacLeod, Kirsty; Srinivasan, Aparna

    2013-07-01

    This study aimed to evaluate the performance of a glucose pattern recognition tool incorporated in a blood glucose monitoring system (BGMS) and its association with clinical measures, and to assess user perception and understanding of the pattern messages they receive. Participants had type 1 or type 2 diabetes mellitus and were self-adjusting insulin doses for ≥1 year. During a 4-week home testing period, participants performed ≥6 daily self-tests, adjusted their insulin regimen based on BGMS results, and recorded pattern messages in the logbook. Participants reflected on usability of the pattern tool in a questionnaire. Study participants (n = 101) received a mean ± standard deviation of 4.5 ± 1.9 pattern messages per week (3.6 ± 1.8 high glucose patterns and 0.9 ± 1.3 low glucose patterns). Most received ≥1 high (96.5%) and/or ≥1 low (46.0%) pattern message per week. The average number of high- and low-pattern messages per week was associated with higher and lower, respectively, baseline hemoglobin A1c (p < .01) and fasting plasma glucose (p < .05). Participants found high- and low-pattern messages clear and easy to understand (84.2% and 83.2%, respectively) and considered the frequency of low (82.0%) and high (63.4%) pattern messages about right. Overall, 71.3% of participants indicated they preferred to use a meter with pattern messages. The on-device Pattern tool identified meaningful blood glucose patterns, highlighting potential opportunities for improving glycemic control in patients who self-adjust their insulin. © 2013 Diabetes Technology Society.

  15. Effects of electroacupuncture on microcirculatory blood flow and glucose transporter function in the hippocampus

    Institute of Scientific and Technical Information of China (English)

    Yan Lu; Bingbing Han; Shijun Wang

    2011-01-01

    Nerve cell metabolism in post brain ischemia depends on increased microcirculation perfusion and transport function of microvascular endothelial cells. In the present study, a rat model of middle cerebral artery occlusion was established to investigate the influence of electroacupuncture(EA)on hippocampal CA1 cerebral blood flow and glucose transporter 1(GLUT1)expression in the microvascular endothelial cp.lls. Following EA at Neiguan(PC 6), the cerebral blood flow in the ischemic hippocampal CA1 region was significantly elevated, the number and microvascular integrated absorbance of the GLUTl-positive cells were significantly increased, nerve cell damage was ameliorated, and GLUT1 protein expression in the ischemic hippocampus was significantly increased. Results demonstrate that EA increased the cerebral blood flow of the hippocampal CA1 region and improved the glucose transport function, thereby attenuating neuronal injuries.

  16. Blood concentrations of lactate, glucose and corticosterone in dispersing hatchling sea turtles

    Directory of Open Access Journals (Sweden)

    Carla M. Pereira

    2012-11-01

    Natal dispersal of sea turtles is an energetically demanding activity that is fuelled primarily by aerobic metabolism. However, during intense exercise reptiles can use anaerobic metabolism to supplement their energy requirements. We assessed anaerobic metabolism in dispersing hatchling loggerhead and flatback turtles by measuring the concentrations of blood lactate during crawling and at different times during the first four hours of their frenzy swim. We also measured concentrations of blood glucose and corticosterone. Blood lactate (12.13 to 2.03 mmol/L, glucose (6.25 to 3.8 mmol/L and corticosterone (8.13 to 2.01 ng/mL concentrations decreased significantly over time in both loggerhead and flatback hatchlings and no significant differences were found between the species. These results indicate that anaerobic metabolism makes a significant contribution to the dispersal phase of hatchling sea turtles during the beach crawl and the first few hours of the frenzy swim.

  17. Implementing home blood glucose and blood pressure telemonitoring in primary care practices for patients with diabetes: lessons learned.

    Science.gov (United States)

    Koopman, Richelle J; Wakefield, Bonnie J; Johanning, Jennifer L; Keplinger, Lynn E; Kruse, Robin L; Bomar, Marilee; Bernt, Beth; Wakefield, Douglas S; Mehr, David R

    2014-03-01

    Prior telemonitoring trials of blood pressure and blood glucose have shown improvements in blood pressure and glycemic targets. However, implementation of telemonitoring in primary care practices may not yield the same results as research trials with extra resources and rigid protocols. In this study we examined the process of implementing home telemonitoring of blood glucose and blood pressure for patients with diabetes in six primary care practices. Grounded theory qualitative analysis was conducted in parallel with a randomized controlled effectiveness trial of home telemonitoring. Data included semistructured interviews with 6 nurse care coordinators and 12 physicians in six participating practices and field notes from exit interviews with 93 of 108 randomized patients. The three stakeholder groups (patients, nurse care coordinators, and physicians) exhibited some shared themes and some unique to the particular stakeholder group. Major themes were that practices should (1) understand the capabilities and limitations of the technology and the willingness of patient and physician stakeholders to use it, (2) understand the workflow, flow of information, and human factors needed to optimize use of the technology, (3) engage and prepare the physicians, and (4) involve the patient in the process. Although there was enthusiasm for a patient-centered medical home model that included between-visit telemonitoring, there was concern about the support and resources needed to provide this service to patients. As with many technology interventions, careful consideration of workflow and information flow will help enable effective implementations.

  18. [Relationship between blood glucose levels and salivary pH and buffering capacity in type II diabetes patients].

    Science.gov (United States)

    Elkafri, I H; Mashlah, A; Shaqifa, A

    2014-03-13

    This study was evaluated the relationship between blood glucose levels and salivary pH and buffering capacity in type II diabetic patients. The sample comprised 210 participants (age ranged 40-60 years). Based on fasting blood glucose levels the participants were divided into 3 groups: controls with normal blood glucose levels; diabetic patients with levels ≤ 200 mg/dL; and diabetic patients with levels > 200 mg/dL. Salivary pH and buffering capacity were determined in a sample of resting (non-stimulated) saliva taken from each participant. Salivary pH levels in diabetic patients with blood glucose levels > 200 mg/dL were lower than in the controls and diabetic patients with levels ≤ 200 mg/dL. Salivary pH levels were comparable in controls and diabetic patients with blood glucose levels ≤ 200 mg/dL. Salivary buffering capacity in the 3 groups was comparable.

  19. Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring.

    Science.gov (United States)

    Tsukamoto, Yuuki; Kinoshita, Yoshihiko; Kitagawa, Hiroyuki; Munekage, Masaya; Munekage, Eri; Takezaki, Yuka; Yatabe, Tomoaki; Yamashita, Koichi; Yamazaki, Rie; Okabayashi, Takehiro; Tarumi, Masatoshi; Kobayashi, Masaki; Mishina, Suguru; Hanazaki, Kazuhiro

    2013-04-01

    A closed-loop glycemic control system using an artificial pancreas has been applied with many clinical benefits in Japan since 1987. To update this system incorporating user-friendly features, we developed a novel artificial pancreas (STG-55). The purpose of this study was to evaluate STG-55 for device usability, performance of blood glucose measurement, glycemic control characteristics in vivo in animal experiments, and evaluate its clinical feasibility. There are several features for usability improvement based on the design concepts, such as compactness, display monitor, batteries, guidance function, and reduction of the preparation time. All animal study data were compared with a clinically available artificial pancreas system in Japan (control device: STG-22). We examined correlations of both blood glucose levels between two groups (STG-55 vs. control) using Clarke's error grid analysis, and also compared mean glucose infusion rate (GIR) during glucose clamp. The results showed strong correlation in blood glucose concentrations (Pearson's product-moment correlation coefficient: 0.97; n = 1636). Clarke's error grid analysis showed that 98.4% of the data fell in Zones A and B, which represent clinically accurate or benign errors, respectively. The difference in mean GIRs was less than 0.2 mg/kg/min, which was considered not significant. Clinical feasibility study demonstrated sufficient glycemic control maintaining target glucose range between 80 and 110 (mg/dL), and between 140 and 160 without any hypoglycemia. In conclusion, STG-55 was a clinically acceptable artificial pancreas with improved interface and usability. A closed-loop glycemic control system with STG-55 would be a useful tool for surgical and critical patients in intensive care units, as well as diabetic patients.

  20. High prevalence of abnormal circadian blood pressure regulation and impaired glucose tolerance in adults with hypopituitarism.

    Science.gov (United States)

    Krzyzanowska, K; Schnack, C; Mittermayer, F; Kopp, H P; Hofer, M; Kann, T; Schernthaner, G

    2005-09-01

    Patients with hypopituitarism have an increased mortality from cardiovascular events. Reduced nocturnal blood pressure decline (non-dipping) and impaired glucose tolerance are considered as cardiovascular risk factors. To evaluate the role of these risk factors in patients with hypopituitarism we determined the 24-hour blood pressure regulation and glucose tolerance status in hypopituitary patients with and without growth hormone (GH) deficiency. Sixty-one hypopituitary subjects 5 +/- 3 years after brain surgery because of macroadenoma, 61 patients with type 2 diabetes mellitus (T2DM), and 20 healthy controls were included. Forty-four hypopituitary patients were GH deficient and 28 of these on GH treatment. Non-dipping was observed in 41 % (n = 7) of hypopituitary subjects with normal GH release, in 46 % (n = 13) of patients on GH therapy, and in 69 % (n = 11) of untreated GH deficient patients. Untreated GH deficient patients had a higher systolic night/day ratio (1.00 +/- 0.03) compared to non GH deficient (0.92 +/- 0.02; p < 0.02) and GH treated hypopituitary patients (0.93 +/- 0.01; p < 0.02). The rate of non-dipping in hypopituitarism was comparable to that in T2DM. Pathologic glucose tolerance was diagnosed in 30 % of the hypopituitary patients. The prevalence of non-dipping was independent of glucose metabolism in hypopituitary patients. All controls had normal night time blood pressure fall and glucose metabolism. The high prevalence of nocturnal non-dipping and glucose intolerance detected in this cohort might contribute to the increased cardiovascular risk of hypopituitary patients.

  1. Blood glucose lowering effect of ophiopogonis tuber extract and mechanism of anti-insulin-resistance

    Directory of Open Access Journals (Sweden)

    Meng NING

    2013-01-01

    Full Text Available Objective  To study the hypoglycemic effect and insulin sensitization mechanism of ophiopogonis tuber extracts on the 3T3-L1-induced adipocytes, and also in rats with reproduction of type 2 diabetes mellitus (T2DM. Methods  3T3-L1 cells were induced and differentiated into adipocytes. After the intervention with ophiopogonpolysaccharide (OPSR and ophiopogonin (OPG, glucose consuming rate was detected for screening the extracts which may have effective hypoglycemic effects. The insulin resistance (IR adipocyte model was established by dexamethasone induction, and then it was treated with OPSR. The protein expression levels of leptin, adiponectin and resistin were detected by Western blotting. The T2DM rat model was reproduced and then treated with OPSR for 4 weeks. Body weight (BW, triglyeride (TG, fasting blood glucose (FBG and fasting insulin (FINs of the rats were measured respectively. Results  OPSR in dosage of 0.5-50mg/L promoted glucose consumption of adipocytes in a dose-dependent manner, the glucose consumption ratios were 32.27%, 75.14% and 90.47% respectively. OPG of 50mg/L showed very weak activity with glucose consumption ratio of only 8.49%. OPSR could significantly promote the protein expression of leptin and adiponectin, and showed an inhibitory effect on the protein expression of resistin (P<0.05. After treatment with OPSR for 4 weeks, the BW of rats increased obviously, while TG, FBG and HOMA-IR decreased significantly (P<0.05 or P<0.01. Conclusions  OPSR may promote glucose transport and utilization of adipocytes, decrease the level of FBG and TG, and improve the condition of IR in T2DM rats. The mechanism of blood glucose lowering effect may be attributed to secretion of adipokines, such as leptin, adiponectin and resistin by IR adipocytes.

  2. Monitoring of glucose, salt and pure water in human whole blood: An in vitro study.

    Science.gov (United States)

    Imran, Muhammad; Ullah, Hafeez; Akhtar, Munir; Sial, Muhammad Aslam; Ahmed, Ejaz; Durr-E-Sabeeh; Ahmad, Mukhtar; Hussain, Fayyaz

    2016-07-01

    Designing and implementation of non-invasive methods for glucose monitoring in blood is main focus of biomedical scientists to provide a relief from skin puncturing of diabete patient. The objective of this research work is to investigate the shape deformations and the aggregation of red blood cells (RBCs) in the human blood after addition of three different analytes i) (0mM-400mM: Range) of glucose (C(6)H(12)O(6)), ii) (0mM-400mM: range) of pure salt (NaCl) and iii) (0mM- 350mM: range) of pure water (H(2)O). We have observed that the changes in the shape of individual cells from biconcave discs to spherical shapes and eventually the lysis of the cells at optimum concentration of glucose, salts and pure water. This demonstration also provides a base line to facilitate diabetes during partial diagnosis and monitoring of the glucose levels qualitatively both in research laboratories and clinical environment.

  3. A signal processing application for evaluating self-monitoring blood glucose strategies in a software agent model.

    Science.gov (United States)

    Wang, Zhanle; Paranjape, Raman

    2015-07-01

    We propose the signal processing technique of calculating a cross-correlation function and an average deviation between the continuous blood glucose and the interpolation of limited blood glucose samples to evaluate blood glucose monitoring frequency in a self-aware patient software agent model. The diabetic patient software agent model [1] is a 24-h circadian, self-aware, stochastic model of a diabetic patient's blood glucose levels in a software agent environment. The purpose of this work is to apply a signal processing technique to assist patients and physicians in understanding the extent of a patient's illness using a limited number of blood glucose samples. A second purpose of this work is to determine an appropriate blood glucose monitoring frequency in order to have a minimum number of samples taken that still provide a good understanding of the patient's blood glucose levels. For society in general, the monitoring cost of diabetes is an extremely important issue, and these costs can vary tremendously depending on monitoring approaches and monitoring frequencies. Due to the cost and discomfort associated with blood glucose monitoring, today, patients expect monitoring frequencies specific to their health profile. The proposed method quantitatively assesses various monitoring protocols (from 6 times per day to 1 time per week) in nine predefined categories of patient agents in terms of risk factors of health status and age. Simulation results show that sampling 6 times per day is excessive, and not necessary for understanding the dynamics of the continuous signal in the experiments. In addition, patient agents in certain conditions only need to sample their blood glucose 1 time per week to have a good understanding of the characteristics of their blood glucose. Finally, an evaluation scenario is developed to visualize this concept, in which appropriate monitoring frequencies are shown based on the particular conditions of patient agents. This base line can

  4. [Today data management in self-monitoring of blood glucose for diabetic patients].

    Science.gov (United States)

    Fermon, C

    2003-04-01

    Improving diabetes treatment needs intensive glucose monitoring which is restricting for patients and time-consuming for physicians. Up-to-date tools of data management were developed, following progress in computing technology and home computing. Glucometers with memory and softwares are able to improve data management of self blood glucose monitoring, personalized interactivity with physician. They are very important to develop telemedecine systems in diabetes care. These systems are designed to complement the daily care and intensive management of diabetics through telemonitoring and telecare services.

  5. Determination of Blood Glucose Concentration by Using Wavelet Transform and Neural Networks

    Directory of Open Access Journals (Sweden)

    Vajravelu Ashok

    2013-03-01

    Full Text Available Background: Early and non-invasive determination of blood glucose level is of great importance. We aimed to present a new technique to accurately infer the blood glucose concentration in peripheral blood flow using non-invasive optical monitoring system.Methods: The data for the research were obtained from 900 individuals. Of them, 750 people had diabetes mellitus (DM. The system was designed using a helium neon laser source of 632.8 nm wavelength with 5mW power, photo detectors and digital storage oscilloscope. The laser beam was directed through a single optical fiber to the index finger and the scattered beams were collected by the photo detectors placed circumferentially to the transmitting fiber. The received signals were filtered using band pass filter and finally sent to a digital storage oscilloscope. These signals were then decomposed into approximation and detail coefficients using modified Haar Wavelet Transform. Back propagation neural and radial basis functions were employed for the prediction of blood glucose concentration.Results: The data of 450 patients were randomly used for training, 225 for testing and the rest for validation. The data showed that outputs from radial basis function were nearer to the clinical value. Significant variations could be seen from signals obtained from patients with DM and those without DM.Conclusion: The proposed non-invasive optical glucose monitoring system is able to predict the glucose concentration by proving that there is a definite variation in hematological distribution between patients with DM and those without DM.

  6. Impact of sodium–glucose cotransporter 2 inhibitors on blood pressure

    Directory of Open Access Journals (Sweden)

    Reed JW

    2016-10-01

    Full Text Available James W Reed Morehouse School of Medicine, Atlanta, GA, USA Abstract: SGLT2 inhibitors are glucose-lowering agents used to treat type 2 diabetes mellitus (T2DM. These agents target the kidney to promote urinary glucose excretion, resulting in improved blood glucose control. SGLT2-inhibitor therapy is also associated with weight loss and blood pressure (BP lowering. Hypertension is a common comorbidity in patients with T2DM, and is associated with excess morbidity and mortality. This review summarizes data on the effect of SGLT2 inhibitors marketed in the US (namely canagliflozin, dapagliflozin, or empagliflozin on BP in patients with T2DM. Boolean searches were conducted that included terms related to BP or hypertension with terms for SGLT2 inhibitors, canagliflozin, dapagliflozin, or empagliflozin using PubMed, Google, and Google Scholar. Data from numerous randomized controlled trials of SGLT2 inhibitors in patients with T2DM demonstrated clinically relevant reductions in both systolic and diastolic BP, assessed via seated office measurements and 24-hour ambulatory BP monitoring. Observed BP lowering was not associated with compensatory increases in heart rate. Circadian BP rhythm was also maintained. The mechanism of SGLT2 inhibitor-associated BP reduction is not fully understood, but is assumed to be related to osmotic diuresis and natriuresis. Other factors that may also contribute to BP reduction include SGLT2 inhibitor-associated decreases in body weight and reduced arterial stiffness. Local inhibition of the renin–angiotensin–aldosterone system secondary to increased delivery of sodium to the juxtaglomerular apparatus during SGLT2 inhibition has also been postulated. Although SGLT2 inhibitors are not indicated as BP-lowering agents, the modest decreases in systolic and diastolic BP observed with SGLT2 inhibitors may provide an extra clinical advantage for the majority of patients with T2DM, in addition to improving blood glucose

  7. Study on the mechanism of human blood glucose concentration measuring using mid-infrared spectral analysis technology

    Science.gov (United States)

    Li, Xiang

    2016-10-01

    All forms of diabetes increase the risk of long-term complications. Blood glucose monitoring is of great importance for controlling diabetes procedure, preventing the complications and improving the patient's life quality. At present, the clinical blood glucose concentration measurement is invasive and could be replaced by noninvasive spectroscopy analytical techniques. The mid-infrared spectral region contains strong characteristic and well-defined absorption bands. Therefore, mid-infrared provides an opportunity for monitoring blood glucose invasively with only a few discrete bonds. Although the blood glucose concentration measurement using mid-infrared spectroscopy has a lot of advantages, the disadvantage is also obvious. The absorption in this infrared region is fundamental molecular group vibration. Absorption intensity is very strong, especially for biological molecules. In this paper, it figures out that the osmosis rate of glucose has a certain relationship with the blood glucose concentration. Therefore, blood glucose concentration could be measured indirectly by measuring the glucose exudate in epidermis layer. Human oral glucose tolerance tests were carried out to verify the correlation of glucose exudation in shallow layer of epidermis layer and blood glucose concentration. As it has been explained above, the mid-infrared spectral region contains well-defined absorption bands, the intensity of absorption peak around 1123 cm-1 was selected to measure the glucose and that around 1170 cm-1 was selected as reference. Ratio of absorption peak intensity was recorded for each set of measurement. The effect and importance of the cleaning the finger to be measured before spectrum measuring are discussed and also verified by experiment.

  8. Poor Reliability and Poor Adherence to Self-Monitoring of Blood Glucose Are Common in Women With Gestational Diabetes Mellitus and May Be Associated With Poor Pregnancy Outcomes.

    Science.gov (United States)

    Cosson, Emmanuel; Baz, Baz; Gary, Françoise; Pharisien, Isabelle; Nguyen, Minh Tuan; Sandre-Banon, Dorian; Jaber, Yahya; Cussac-Pillegand, Camille; Banu, Isabela; Carbillon, Lionel; Valensi, Paul

    2017-09-01

    To evaluate the compliance with self-monitoring of blood glucose (SMBG) and the reliability of diabetes logbooks in women with gestational diabetes mellitus (GDM), as well as the associated determinants and outcomes. We prospectively selected French-speaking women with newly diagnosed GDM who had been referred to our diabetes management program and understood SMBG principles. At the next follow-up visit, we collected SMBG results from glucose meters and logbooks. We analyzed pregnancy outcomes. Data were analyzed over 13 ± 3 days in 91 women. Only 61.5% had performed ≥80% of the required tests. Poor compliance was associated with a family history of diabetes, social deprivation, and non-European origin. The average time between pre- and postprandial tests was 141 ± 20 min, with 46.5% of women performing ≥80% of postprandial measurements 100-140 min after meals. Inadequate timing was associated with ethnicity and higher HbA1c at baseline. A total of 23.1% of women had <90% matched values in diary and meter memory, and a poor concordance was associated with a family history of diabetes. Poor adherence was associated with more preeclampsia (12.2 vs. 1.9%, P = 0.049), and inadequate postprandial test timing with a higher HbA1c at delivery (5.3 ± 0.4 vs. 5.0 ± 0.3% [34 ± 2 vs. 31 ± 2 mmol/mol], P < 0.01), despite more frequent insulin therapy. Although women with GDM are considered to be highly motivated, SMBG adherence and reliability are of concern and may be associated with poor gestational prognosis, suggesting that caregivers should systematically check the glucose meter memory to improve GDM management. © 2017 by the American Diabetes Association.

  9. Capillary flow of blood in a microchannel with differential wetting for blood plasma separation and on-chip glucose detection.

    Science.gov (United States)

    Maria, M Sneha; Rakesh, P E; Chandra, T S; Sen, A K

    2016-09-01

    We report capillary flow of blood in a microchannel with differential wetting for the separation of a plasma from sample blood and subsequent on-chip detection of glucose present in a plasma. A rectangular polydimethylsiloxane microchannel with hydrophilic walls (on three sides) achieved by using oxygen plasma exposure enables capillary flow of blood introduced at the device inlet through the microchannel. A hydrophobic region (on all four sides) in the microchannel impedes the flow of sample blood, and the accumulated blood cells at the region form a filter to facilitate the separation of a plasma. The modified wetting property of the walls and hence the device performance could be retained for a few weeks by covering the channels with deionised water. The effects of the channel cross-section, exposure time, waiting time, and location and length of the hydrophobic region on the volume of the collected plasma are studied. Using a channel cross-section of 1000 × 400 μm, an exposure time of 2 min, a waiting time of 10 min, and a hydrophobic region of width 1.0 cm located at 10 mm from the device inlet, 450 nl of plasma was obtained within 15 min. The performance of the device was found to be unaffected (provides 450 nl of plasma in 15 min) even after 15 days. The purification efficiency and plasma recovery of the device were measured and found to be comparable with that obtained using the conventional centrifugation process. Detection of glucose at different concentrations in whole blood of normal and diabetic patients was performed (using 5 μl of sample blood within 15 min) to demonstrate the compatibility of the device with integrated detection modules.

  10. Impact of Dietary Acculturation on the Food Habits, Weight, Blood Pressure, and Fasting Blood Glucose Levels of International College Students.

    Science.gov (United States)

    Almohanna, Amal; Conforti, Frank; Eigel, William; Barbeau, William

    2015-01-01

    This study was conducted to determine the impact of dietary acculturation on the health status of newly arrived international students at Virginia Tech in Fall 2010. Thirty-five international students, 18-36 years of age, completed the study. Data were collected at 3 different time periods (V1, V2, and V3) approximately 6 weeks apart. A food frequency- and dietary pattern-related questionnaire was administered and numerically coded responses were analyzed. Twenty-four-hour dietary recall data were also collected at V1, V2, and V3. Body weight, fasting blood glucose level, and blood pressure of study participants were also determined at each time period. Total sample population (TSP) had a significant increase in mean weight of 2.79 lb from visit 1 (V1) to visit 3 (V3) (p = .0082). Ten participants gained an average of 9.0 lb (participants who gained weight; n = 10). There was also an increase in the frequency of consumption of high-calorie American food items from V1 to V3. However, there were no significant changes in mean systolic blood pressure and mean fasting blood glucose was significantly lower at V3 than at V1. There was a gradual shift in the dietary patterns of international students towards the American diet. Dietary acculturation led to weight gain among some of the students, which may potentially have a negative impact on their health status if continued for longer time periods.

  11. Blood glucose regulation during fasting in rats under food restriction since birth

    Directory of Open Access Journals (Sweden)

    Adriana de Souza Vitoriano

    2011-02-01

    Full Text Available The effect of severe food restriction since birth on regulation of fasting glycemia in male Wistar rats was investigated. The control group (CG had free supply of chow, while the restriction group (RG received 50% of the amount ingested by the CG. The experiments were done in adult (60 days overnight fasted rats in which glycemia, liver free glucose levels and hepatic glycogen concentration were measured. In part of the experiments in situ liver perfusion was done. The results showed that livers from the RG had higher glycogenolysis rates but lower gluconeogenesis rates from L-alanine (10 mM. Since RG showed maintained glycemia during fasting, it could be concluded that livers from RG produced glucose preferentially from glycogenolysis in detriment of gluconeogenesis. These findings demonstrated that in spite of severe caloric restriction, the metabolic adaptations of the liver did exist to assure the maintenance of blood glucose for brain supply during fasting.

  12. Angiotensin II receptor blockers decreased blood glucose levels: a longitudinal survey using data from electronic medical records

    Directory of Open Access Journals (Sweden)

    Yamadate Shuukoh

    2007-09-01

    Full Text Available Abstract Background A beneficial effect on glucose metabolism is reported with angiotensin receptor blocker (ARB treatment of hypertension. The effect on blood glucose level during the course of treatment with ARBs in clinical cases is uncertain. Our objectives were to survey the changes in glucose and HbA1c levels in patients with hypertension over a one-year period, and to study the correlations between these values and the time after the start of ARB therapy. Methods We conducted a retrospective longitudinal survey of blood glucose and HbA1c measurements in Japanese patients aged ≥20 years with newly diagnosed hypertension but without diabetes, who had received ARB monotherapy with candesartan cilexetil, losartan potassium, olmesartan medoxomil, telmisartan, or valsartan during the period from December 2004 to November 2005. Data including 2465 measurements of non-fasting blood glucose in 485 patients and 457 measurements of HbA1c in 155 patients were obtained from electronic medical records of Nihon University School of Medicine. Linear mixed effects models were used to analyze the relationship between these longitudinal data of blood examinations and covariates of patient age, sex, medication, and duration of ARB therapy. Results Casual blood glucose level was associated with the duration of treatment (P Conclusion Our findings provide new clinical evidence that the effects of ARBs on glucose metabolism may change during the course of treatment, suggesting a blood glucose-lowering effect in the short-term after the start of treatment.

  13. The impact of high-dose vitamin C on blood glucose testing in ¹⁸F-FDG PET imaging.

    Science.gov (United States)

    Bahr, Rebekah L; Wilson, Don C

    2015-03-01

    Complementary and alternative therapies in addition to standard oncology protocols are commonly sought by cancer patients; however, few patients disclose their complementary treatments to their cancer care team. A lack of communication may result in unforeseen side effects and the potential for some alternative therapies to interfere with or inhibit conventional treatment. High-dose vitamin C therapy, in particular, may lead to an inability to measure a patient's blood glucose level before (18)F-FDG injection for PET/CT scanning. We report a case of a 52-y-old woman referred for (18)F-FDG PET/CT to evaluate the extent of recurrent colorectal cancer. The PET/CT scan immediately followed a single intravenous dose of 25 g of ascorbic acid from her naturopath. A glucometer that applies the glucose oxidase method for measuring fasting blood glucose was used, for which high doses of vitamin C are listed as a contraindication. The high concentration of ascorbic acid in the patient's blood sample interfered with the chemical reaction on the glucose strip, and therefore no blood glucose measurement could be attained. With more patients receiving alternative and complementary cancer therapies, it is important to know what the implications of orthomolecular therapy might be on routine blood glucose testing for (18)F-FDG PET scans. (18)F-FDG is in direct competition with glucose; therefore, elevated blood glucose levels will cause a decrease in (18)F-FDG absorption and may lead to a false-negative scan.

  14. Proposed Application of Fast Fourier Transform in Near Infra Red Based Non Invasive Blood Glucose Monitoring System

    Science.gov (United States)

    Jenie, R. P.; Iskandar, J.; Kurniawan, A.; Rustami, E.; Syafutra, H.; Nurdin, N. M.; Handoyo, T.; Prabowo, J.; Febryarto, R.; Rahayu, M. S. K.; Damayanthi, E.; Rimbawan; Sukandar, D.; Suryana, Y.; Irzaman; Alatas, H.

    2017-03-01

    Worldwide emergence of glycaemic status related health disorders, such as diabetes and metabolic syndrome, is growing in alarming rate. The objective was to propose new methods for non invasive blood glucose level measurement system, based on implementation of Fast Fourier Transform methods. This was an initial-lab-scale-research. Data on non invasive blood glucose measurement are referred from Scopus, Medline, and Google Scholar, from 2011 until 2016, and was used as design references, combined with in house verification. System was developed in modular fashion, based on aforementioned compiled references. Several preliminary tests to understand relationship between LED and photo-diode responses have been done. Several references were used as non invasive blood glucose measurement tools design basis. Solution is developed in modular fashion. we have proven different sensor responses to water and glucose. Human test for non invasive blood glucose level measurement system is needed.

  15. Blood glucose and cholesterol levels in adult population of Bangladesh: Results from STEPS 2006 survey.

    Science.gov (United States)

    Zaman, M Mostafa; Choudhury, Sohel Reza; Ahmed, Jasimuddin; Talukder, Md Habibullah; Rahman, A H M Shafiqur

    2016-01-01

    A nationally representative survey was carried out to determine the distribution of blood glucose and cholesterol in adult population of Bangladesh in the absence of existing data. The study adopted a multistage and geographically clustered sampling technique of households. A total of 2610 individuals (1444 men and 1166 women) aged 25-64 years were selected from rural and urban areas. Capillary blood glucose and total cholesterol levels were measured using an overnight fasting state. The mean age of the participants was 41 years [standard deviation (SD), 11 years]. Half of them (49%) were from urban areas. Half of them (51%) had primary or higher education. Mean glucose was 74mg/dL (SD 23mg/dL). Men had higher mean glucose levels (79mg/dL) than women (67mg/dL). Age-standardized prevalence of diabetes (blood glucose level ≥126mg/dL and/or use of anti-diabetic medication) was 5.5%. In men, it was almost two-and-half times (7.6%) compared with women (2.8%). It was also double in urban areas (7.8%) compared with rural areas (3.4%). Mean cholesterol level among all participants was 167mg/dL (SD 26mg/dL). Men and women had almost similar levels (169mg/dL versus 166mg/dL, respectively). Prevalence of high cholesterol level (≥240mg/dL) was very low (1.3%) in both men (2.2%) and women (0.5%). However, the prevalence of borderline high cholesterol was substantial (5.8%) in this sample. The prevalence of high hypercholesterolemia is low, whereas there is a high prevalence of borderline high cholesterol and diabetes in the adult population of Bangladesh. This warrants population-based interventions to tackle this problem. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  16. Evaluation of sildenafil pressurized metered dose inhalers as a vasodilator in umbilical blood vessels of chicken egg embryos.

    Science.gov (United States)

    Sawatdee, Somchai; Hiranphan, Phetai; Laphanayos, Kampanart; Srichana, Teerapol

    2014-01-01

    Sildenafil citrate is a selective phosphodiesterase-5 inhibitor used for the treatment for erectile dysfunction and pulmonary hypertension. The delivery of sildenafil directly to the lung could have several advantages over conventional treatments for pulmonary hypertension because of the local delivery, a more rapid onset of response, and reduced side effects. The major problem of sildenafil citrate is its limited solubility in water. Sildenafil citrate was complexed with cyclodextrins (CDs) to enhance its water solubility prior to development as an inhaled preparation. Four sildenafil citrate inhaled formulations were prepared with the aid of HP-β-CD (#1), α-CD (#2) and γ-CD (#3) and their effects were compared with the formulations without CDs (#4). The sildenafil citrate pressurized metered dose inhalers (pMDI) used ethanol as a solvent, PEG400 as a stabilizing agent, sorbitan monooleate as a surfactant and HFA-134a as a propellant. All formulations consisted of sildenafil citrate equivalent to a sildenafil content of 20μg/puff. These products were evaluated according to a standard guideline of inhalation products. Vasodilation testing was performed to investigate the efficacy of sildenafil pMDIs in relieving a vasoconstricted umbilical blood vessel of the chicken egg embryo. The sildenafil contents of the pMDI formulations #1-#3 were within the acceptance criteria (80-120%). The emitted doses (ED) were 102.3±11.5%, the fine particle fractions (FPF) were 60.5±5.6% and the mass median aerodynamic diameters (MMAD) were 2.3±0.3μm. The vasodilatory activity of those formulations reduced umbilical blood pressure by 67.1-73.7% after treatment by intravenous injection whereas only a 50.1-58.0% reduced blood pressure was obtained after direct spraying of the sildenafil pMDI containing CDs. With sildenafil formulations of a pMDI without CD the blood pressure was reduced by only 39.0% (P-valuevessels of chicken egg embryos after spraying sildenafil-CDs pMDIs was

  17. Variations in Postprandial Blood Glucose Responses and Satiety after Intake of Three Types of Bread

    Directory of Open Access Journals (Sweden)

    Marianne S. H. Lunde

    2011-01-01

    Full Text Available Background. The magnitude and duration of postprandial blood glucose (PPG elevations are important risk factors of diabetes and coronary heart diseases. Aim. To study PPG after ingestion of breads with and without pea fibre and rapeseed oil. Methods. After fasting overnight, 10 Pakistani immigrant women participated in three experiments having a crossover design and involving ingestion of various types of bread: regular coarse bread or fibre enriched-bread with two levels of rapeseed oil, all providing 25 g available carbohydrates (CHO. Blood glucose and satiety were determined before the meal and every 15 min over the next 2 hours. Results. Intake of an amount of pea fibre-enriched bread containing 25 g CHO attenuated, the postprandial peak glucose value, the incremental area under the glucose versus time curve during 15 to 75 min, and the glycemic profile, and increased duration of satiety (<.05, as compared with intake of regular bread with 25 g carbohydrate. Conclusion. Pea fibre-enriched breads can reduce PPG and prolong satiety.

  18. Serum fructosamine concentration as measure of blood glucose control in type I (insulin dependent) diabetes mellitus.

    Science.gov (United States)

    Baker, J R; Metcalf, P A; Holdaway, I M; Johnson, R N

    1985-01-01

    Serum fructosamine activity was studied in 42 patients with type I (insulin dependent) diabetes mellitus and 30 non-diabetic volunteers as an index of blood glucose control. There was a significant correlation both between fructosamine and glycosylated haemoglobin values (r = 0.82) and between fructosamine and the fasting C peptide concentration (r = -0.81). Test results in 14 of the diabetics reflected the mean plasma glucose concentration calculated from 25 serial estimations in a single 24 hour period (r = 0.75; p less than 0.01) but not the mean amplitude of glycaemic excursion (r = 0.23; p greater than 0.05). Fructosamine concentrations measured in these multiple blood specimens did not change significantly throughout the day (mean coefficient of variation 4.1%) despite wide variability of the respective plasma glucose concentrations (mean coefficient of variation 36.2%). It is concluded that a single random serum sample analysed for fructosamine concentration provides a simple and reliable assessment of glucose homoeostasis in patients with type I diabetes mellitus. PMID:3917816

  19. Garlic intake lowers fasting blood glucose: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Hou, Li-qiong; Liu, Yun-hui; Zhang, Yi-yi

    2015-01-01

    Garlic is a common spicy flavouring agent also used for certain therapeutic purposes. Garlic's effects on blood glucose have been the subject of many clinical and animal studies, however, studies reporting hypoglycemic effects of garlic in humans are conflicting. A comprehensive literature search was conducted to identify relevant trials of garlic or garlic extracts on markers of glycemic control [fasting blood glucose (FBG), postprandial glucose (PPG), glycosylated haemoglobin (HbA1c)]. A meta-analysis of the effect of garlic intake on human was done to assess garlic's effectiveness in lowering glucose levels. Two reviewers extracted data from each of the identified studies. Seven eligible randomized controlled trials with 513 subjects were identified. Pooled analyses showed that garlic intake results in a statistically significant lowering in FBG [SMD=-1.67; 95% CI (-2.80, -0.55), p=0.004]. Our pooled analyses did not include PPG control and HbA1c outcomes. Because only 1 study included in the meta-analysis reported PPG variables and only 2 studies reported HbA1c variables. In conclusion, the current meta-analysis showed that the administration of garlic resulted in a significant reduction in FBG concentrations. More trials are needed to investigate the effectiveness of garlic on HbA1c and PPG.

  20. Scale Space Methods for Analysis of Type 2 Diabetes Patients' Blood Glucose Values

    Directory of Open Access Journals (Sweden)

    Stein Olav Skrøvseth

    2011-01-01

    Full Text Available We describe how scale space methods can be used for quantitative analysis of blood glucose concentrations from type 2 diabetes patients. Blood glucose values were recorded voluntarily by the patients over one full year as part of a self-management process, where the time and frequency of the recordings are decided by the patients. This makes a unique dataset in its extent, though with a large variation in reliability of the recordings. Scale space and frequency space techniques are suited to reveal important features of unevenly sampled data, and useful for identifying medically relevant features for use both by patients as part of their self-management process, and provide useful information for physicians.

  1. Ontogenetic oxygen changes alter zebra fish size, behavior, and blood glucose.

    Science.gov (United States)

    Marks, C; Kaut, K P; Moore, F B-G; Bagatto, B

    2012-01-01

    Four male and four female zebra fish were crossed in all possible combinations, resulting in 389 offspring. These offspring were divided among four treatments: normoxia for 90 d, hypoxia for 90 d, normoxia for 30 d followed by hypoxia for 60 d, and hypoxia for 30 d followed by normoxia for 60 d. The effects of early oxygen environment, later oxygen environment, and genotype were then assessed with respect to zebra fish behavior, size, and blood glucose. Fish were tested in an arena where they could shoal with conspecifics before, during, and after the introduction of a novel stimulus. Blood glucose and size were also measured. Early oxygen environment influenced fish size, time spent swimming, and reactivity to a novel stimulus. Environmentally induced plasticity was predominate, with little evidence of among-sire variation for any of the measured parameters.

  2. Frequency and motives of blood glucose self-monitoring in type 1 diabetes

    DEFF Research Database (Denmark)

    Hansen, M V; Pedersen-Bjergaard, U; Heller, S R

    2009-01-01

    AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural and demograp......AIMS: Recommendations for self-monitoring of blood glucose (SMBG) from the DCCT have not been implemented with the same rigour as recommendations for intensifying insulin therapy. We assessed the frequency of and motives for SMBG and compared SMBG behaviour with clinical, behavioural...... hypoglycaemia and awareness of hypoglycaemia were independently associated with testing behaviour, whereas the presence of late diabetic complications was not. Lower HbA1c was associated with more frequent testing. CONCLUSION: Patient compliance regarding SMBG is limited. Thus, almost two thirds of the patients...

  3. Diabetes mellitus, fasting blood glucose concentration, and risk of vascular disease

    DEFF Research Database (Denmark)

    Sarwar, N; Gao, P; Seshasai, S R Kondapally

    2010-01-01

    BACKGROUND: Uncertainties persist about the magnitude of associations of diabetes mellitus and fasting glucose concentration with risk of coronary heart disease and major stroke subtypes. We aimed to quantify these associations for a wide range of circumstances. METHODS: We undertook a meta......-analysis of individual records of diabetes, fasting blood glucose concentration, and other risk factors in people without initial vascular disease from studies in the Emerging Risk Factors Collaboration. We combined within-study regressions that were adjusted for age, sex, smoking, systolic blood pressure, and body......-mass index to calculate hazard ratios (HRs) for vascular disease. FINDINGS: Analyses included data for 698 782 people (52 765 non-fatal or fatal vascular outcomes; 8.49 million person-years at risk) from 102 prospective studies. Adjusted HRs with diabetes were: 2.00 (95% CI 1.83-2.19) for coronary heart...

  4. Oral calcium pectinate-insulin nanoparticles: influences of alginate, sodium chloride and Tween 80 on their blood glucose lowering performance.

    Science.gov (United States)

    Wong, Tin W; Sumiran, Nurjaya

    2014-05-01

    Examine the formation of pectin-insulin nanoparticles and their blood glucose lowering properties. The calcium pectinate nanoparticles were prepared by ionotropic gelation method, with alginate, sodium chloride or Tween 80 as additive. Their in vitro physicochemical, drug release and in vivo blood glucose lowering characteristics were evaluated. Spherical calcium pectinate-insulin nanoparticles were characterized by size, zeta potential, insulin content and insulin association efficiency of 348.4 ± 12.9 nm, -17.9 ± 0.8 mV, 8.4 ± 1.0% and 63.8 ± 7.4%, respectively. They released less than 25% insulin following 24 h in simulated intestinal medium and exhibited delayed blood glucose lowering effect in rats. Incorporation of solubilizer sodium chloride or Tween 80 into nanoparticles did not enhance blood glucose lowering capacity owing to sodium chloride reduced matrix insulin content and Tween 80 interacted with water and had its blood glucose dilution effect negated. Combination of nanoparticles with alginate gel to allow prolonged intestinal residence and more insulin release did not enhance their blood glucose lowering capacity because of calcium alginate-cross-linked gel formation that could retard insulin release and migration into systemic circulation. Physicochemical responses of additives in vivo affected blood glucose regulation property of pectin-insulin nanoparticles. © 2013 Royal Pharmaceutical Society.

  5. High activity enables life on a high-sugar diet: blood glucose regulation in nectar-feeding bats.

    Science.gov (United States)

    Kelm, Detlev H; Simon, Ralph; Kuhlow, Doreen; Voigt, Christian C; Ristow, Michael

    2011-12-01

    High blood glucose levels caused by excessive sugar consumption are detrimental to mammalian health and life expectancy. Despite consuming vast quantities of sugar-rich floral nectar, nectar-feeding bats are long-lived, provoking the question of how they regulate blood glucose. We investigated blood glucose levels in nectar-feeding bats (Glossophaga soricina) in experiments in which we varied the amount of dietary sugar or flight time. Blood glucose levels increased with the quantity of glucose ingested and exceeded 25 mmol l(-1) blood in resting bats, which is among the highest values ever recorded in mammals fed sugar quantities similar to their natural diet. During normal feeding, blood glucose values decreased with increasing flight time, but only fell to expected values when bats spent 75 per cent of their time airborne. Either nectar-feeding bats have evolved mechanisms to avoid negative health effects of hyperglycaemia, or high activity is key to balancing blood glucose levels during foraging. We suggest that the coevolutionary specialization of bats towards a nectar diet was supported by the high activity and elevated metabolic rates of these bats. High activity may have conferred benefits to the bats in terms of behavioural interactions and foraging success, and is simultaneously likely to have increased their efficiency as plant pollinators.

  6. Effects of breakfast with different calorigenic amounts on blood glucose, insulin and glucagon levels

    Institute of Scientific and Technical Information of China (English)

    HUANG Su-xia(黄素霞); FU Yun-xing(傅运兴); WANG Hui-ming(王慧铭); GIANG Sylvia

    2003-01-01

    This study was aimed to investigate the relationship between breakfast and serum glucose, insulin and glucagon concentrations in order to establish a model breakfast appropriate for Chinese. Twenty-four volunteers were randomly assigned to four study groups: high carbohydrate breakfast, high fat and protein breakfast, the typical breakfast and fasting. Each subject had serum and urine samples collected while fasting and at 1,2 and 3.5 hours following the meal. The concentration of serum glucose, insulin and glucagon was measured. The levels of serum glucose in group A,B and C differed significantly at 1 and 2 hour after meal compared to those at fasting (P<0.05). The serum glucose in group A increased insignificantly after meal. The serum insulin levels were in group A,B and C significant different compared with control group(P<0.05).Those peaked at 1 hour after meal ,with group C rising the furthest. Compared with the fasting group, the serum glucagons rose and maintained the increase after breakfast in group A,B and C (P<0.05).The data suggested that various diets with different calorigenic amounts increased hormone concentration to various extents. We found that a breakfast rich in carbohydrates could maintain proper blood glucose level.

  7. Effect of Jiang Zhuo Mixture on Blood Glucose Level and Insulin Resistance in Diabetes

    Institute of Scientific and Technical Information of China (English)

    Chen Xiabo; Wang Hui

    2005-01-01

    @@ Based on the knowledge of diabetes in traditional Chinese medicine and modem biomedical sciences,Dr. Wang Hui (王晖) designed Jiang Zhuo Mixture (降浊合剂) , a preparation for treatment of fat diabetes type 2. Jiang Zhuo Mixture showed good actions of strengthening the spleen and stomach,separating the clear from the turbid, resolving the stasis and decreasing the blood glucose level. These were reported as follows.

  8. Effects of passive static stretching on blood glucose levels in patients with type 2 diabetes mellitus

    OpenAIRE

    Park, Seong Hoon

    2015-01-01

    [Purpose] This study determined the effects of passive static stretching on blood glucose levels in patients with type 2 diabetes. [Subjects] Fifteen patients (8 males and 7 females) with type 2 diabetes were recruited and randomly assigned to the control group or passive static stretching group. [Methods] Glycated hemoglobin was measured before and after the 8-week training period. [Results] Glycated hemoglobin levels decreased significantly in the passive static stretching group, and there ...

  9. RETRACTED: Bosentan attenuates cardiac fibrosis in diabetic mice without affecting blood glucose.

    Science.gov (United States)

    Yang, Bo; Chen, Yun-Dai; Li, Min; Zhou, Fei-Hu; Xu, Yong; Wang, Guang-Yi; Li, Tian-De; Xing, You-Hong

    2015-12-01

    At the request of the authors, 'Bosentan attenuates cardiac fibrosis in diabetic mice without affecting blood glucose' Journal of Renin-Angiotensin-Aldosterone System, published ahead of print August 15, 2011 as doi: 10.1177/1470320311417274 has been retracted. This is due to mistakes in the published data at Figure 3. For clarification: this problem came to the attention of Bo Yang only after publication in the journal. Bo Yang immediately brought it to the attention of the Journal.

  10. Chronic fructose substitution for glucose or sucrose in food or beverages has little effect on fasting blood glucose, insulin, or triglycerides: a systematic review and meta-analysis.

    Science.gov (United States)

    Evans, Rebecca A; Frese, Michael; Romero, Julio; Cunningham, Judy H; Mills, Kerry E

    2017-08-01

    Background: Conflicting evidence exists on the role of long-term fructose consumption on health. No systematic review has addressed the effect of isoenergetic fructose replacement of other sugars and its effect on glycated hemoglobin (HbA1c), fasting blood glucose, insulin, and triglycerides.Objective: The objective of this study was to review the evidence for a reduction in fasting glycemic and insulinemic markers after chronic, isoenergetic replacement of glucose or sucrose in foods or beverages by fructose. The target populations were persons without diabetes, those with impaired glucose tolerance, and those with type 2 diabetes.Design: We searched the Cochrane Library, MEDLINE, EMBASE, the WHO International Clinical Trials Registry Platform Search Portal, and clinicaltrials.gov The date of the last search was 26 April 2016. We included randomized controlled trials of isoenergetic replacement of glucose, sucrose, or both by fructose in adults or children with or without diabetes of ≥2 wk duration that measured fasting blood glucose. The main outcomes analyzed were fasting blood glucose and insulin as well as fasting triglycerides, blood lipoproteins, HbA1c, and body weight.Results: We included 14 comparison arms from 11 trials, including 277 patients. The studies varied in length from 2 to 10 wk (mean: 28 d) and included doses of fructose between 40 and 150 g/d (mean: 68 g/d). Fructose substitution in some subgroups resulted in significantly but only slightly lowered fasting blood glucose (-0.14 mmol/L; 95% CI: -0.24, -0.036 mmol/L), HbA1c [-10 g/L (95% CI: -12.90, -7.10 g/L; impaired glucose tolerance) and -6 g/L (95% CI: -8.47, -3.53 g/L; normoglycemia)], triglycerides (-0.08 mmol/L; 95% CI: -0.14, -0.02 mmol/L), and body weight (-1.40 kg; 95% CI: -2.07, -0.74 kg). There was no effect on fasting blood insulin or blood lipids.Conclusions: The evidence suggests that the substitution of fructose for glucose or sucrose in food or beverages may be of benefit to

  11. Effects of laser acupoint irradiation on blood glucose and glycosylated hemoglobin in type 2 diabetes mellitus

    Science.gov (United States)

    Hui-Hui, Liu; Guo-Xin, Xiong; Li-Ping, Zhang

    2016-06-01

    To investigate the effects of semiconductor laser acupoint irradiation on blood glucose, glycosylated hemoglobin and physical fitness in type 2 diabetes mellitus, 44 cases of type 2 diabetic patients were randomly divided into a control group and a treatment group. All patients in both groups were given a drug treatment. The Hegu, Quchi and Zusanli acupoints of patients in the treatment group were then irradiated daily for 15 d with a 10 MW semiconductor laser. Before and after treatment, patients in both groups underwent a variety of tests and measurements: a two-hour postprandial blood glucose test; a glycosylated hemoglobin test and body mass index (BMI), waist-to-hip ratio (WHR) and body fat percentage (BFP) measurements. The data detected after treatment greatly decreased in the treatment group and was significantly different from that in the control group. It is shown that the acupoint irradiation with a semiconductor laser can improve two-hour postprandial blood glucose, glycosylated hemoglobin and some physical fitness measurements in type 2 diabetes mellitus patients.

  12. Effect of Iranian Honey bee (Apis Mellifera Venom on Blood Glucose and Insulin in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Seyyedeh Mahbubeh Mousavi

    2012-12-01

    Full Text Available Background: Diabetes is an important disease. This disease is a metabolic disorder characterized by hyperglycemia resulting from perturbation in insulin secretion, insulin action or both. Honey bee venom contains a wide range of polypeptide agents. The principle components of bee venom are mellitin and phospholipase A2. These components increase insulin secretion from the β-cells of pancreas. This study was conducted to show the hypoglycemic effect of honey bee venom on alloxan induced diabetic male rats.Methods: Eighteen adult male rats weighting 200±20 g were placed into 3 randomly groups: control, alloxan monohy­drate-induced diabetic rat and treated group that received honey bee venom daily before their nutrition for four months. Forty eight hours after the last injection, blood was collected from their heart, serum was dissented and blood glucose, insulin, triglyceride and total cholesterol were determined.Results: Glucose serum, triglyceride and total cholesterol level in treated group in comparison with diabetic group was significantly decreased (P< 0.01. On the other hand, using bee venom causes increase in insulin serum in com­parison with diabetic group (P< 0.05.Conclusion: Honeybee venom (apitoxin can be used as therapeutic option to lower blood glucose and lipids in dia­betic rats.

  13. Remote Blood Glucose Monitoring in mHealth Scenarios: A Review

    Directory of Open Access Journals (Sweden)

    Giordano Lanzola

    2016-11-01

    Full Text Available Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient’s significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators.

  14. Research on the multiple linear regression in non-invasive blood glucose measurement.

    Science.gov (United States)

    Zhu, Jianming; Chen, Zhencheng

    2015-01-01

    A non-invasive blood glucose measurement sensor and the data process algorithm based on the metabolic energy conservation (MEC) method are presented in this paper. The physiological parameters of human fingertip can be measured by various sensing modalities, and blood glucose value can be evaluated with the physiological parameters by the multiple linear regression analysis. Five methods such as enter, remove, forward, backward and stepwise in multiple linear regression were compared, and the backward method had the best performance. The best correlation coefficient was 0.876 with the standard error of the estimate 0.534, and the significance was 0.012 (sig. regression equation was valid. The Clarke error grid analysis was performed to compare the MEC method with the hexokinase method, using 200 data points. The correlation coefficient R was 0.867 and all of the points were located in Zone A and Zone B, which shows the MEC method provides a feasible and valid way for non-invasive blood glucose measurement.

  15. [Correlation between resting heart rate and blood glucose level in elderly patients with coronary heart disease and diabetes mellitus].

    Science.gov (United States)

    Liang, Dong-Liang; Li, Xiao-Ying; Wang, Lin; Xu, Hao; Tuo, Xi-Ping; Jian, Zai-Jin; Wang, Xiao-Na; Yun, Ji-Li; Zhang, Xu; Wang, Si-Yue

    2016-05-01

    To explore the correlation between resting heart rate (RHR) and blood glucose level in elderly patients with coronary heart disease (CHD) complicated by diabetes mellitus. Between April and July, 2011, a total of 1336 outpatients over 60 years of age recruited from 165 hospitals were asked to complete a questionnaire and received blood glucose and RHR examination. According to baseline RHR, the patients were divided into 3 groups with HRH blood glucose control rate. HbA1c levels in the total, male and female patients differed significantly among the 3 groups (F=15.436, 15.436, and 24.270, respectively, PBlood glucose control rate in the total, male and female patients also differed significantly among the 3 groups (χ(2)=13.471, 6.752, and 6.522, respectively, Pblood glucose control failure of 1.99 (95% CI: 1.23-2.37, Pblood glucose level, and an increased RHR is associated with an increased risk of poor blood glucose control. Rigorous RHR control in such high-risk patients may prove beneficial for both blood glucose control and secondary prevention of CHD.

  16. Acute effects of traditional Japanese alcohol beverages on blood glucose and polysomnography levels in healthy subjects

    Directory of Open Access Journals (Sweden)

    Megumi Kido

    2016-04-01

    Full Text Available Background. Alcohol consumption is a lifestyle factor associated with type 2 diabetes. This relationship is reportedly different depending on the type of alcohol beverage. The purpose of this study was to examine the acute effects of traditional Japanese alcohol beverages on biochemical parameters, physical and emotional state, and sleep patterns. Methods. Six healthy subjects (three men and three women; age, 28.8 ± 9.5 years; body mass index, 21.4 ± 1.6 kg/m2 consumed three different types of alcohol beverages (beer, shochu, and sake, each with 40 g ethanol or mineral water with dinner on different days in the hospital. Blood samples were collected before and 1, 2, and 12 h after drinking each beverage, and assessments of physical and emotional state were administered at the same time. In addition, sleep patterns and brain waves were examined using polysomnography. Results. Blood glucose levels at 1 h and the 12-h area under the curve (AUC value after drinking shochu were significantly lower than that with water and beer. The 12-h blood insulin AUC value after drinking shochu was significantly lower than that with beer. Blood glucose × insulin level at 1 h and the 2-h blood glucose × insulin AUC value with shochu were significantly lower than that with beer. The insulinogenic indexes at 2 h with beer and sake, but not shochu, were significantly higher than that with water. The visual analogue scale scores of physical and emotional state showed that the tipsiness levels with beer, shochu, and sake at 1 h were significantly higher than that with water. These tipsiness levels were maintained at 2 h. The polysomnography showed that the rapid eye movement (REM sleep latency with shochu and sake were shorter than that with water and beer. Conclusions. Acute consumption of alcohol beverages with a meal resulted in different responses in postprandial glucose and insulin levels as well as REM sleep latency. Alcohol beverage type should be taken into

  17. Acute effects of traditional Japanese alcohol beverages on blood glucose and polysomnography levels in healthy subjects

    Science.gov (United States)

    Kido, Megumi; Asakawa, Akihiro; Koyama, Ken-Ichiro K.; Takaoka, Toshio; Tajima, Aya; Takaoka, Shigeru; Yoshizaki, Yumiko; Okutsu, Kayu; Takamine, Kazunori T.; Sameshima, Yoshihiro

    2016-01-01

    Background. Alcohol consumption is a lifestyle factor associated with type 2 diabetes. This relationship is reportedly different depending on the type of alcohol beverage. The purpose of this study was to examine the acute effects of traditional Japanese alcohol beverages on biochemical parameters, physical and emotional state, and sleep patterns. Methods. Six healthy subjects (three men and three women; age, 28.8 ± 9.5 years; body mass index, 21.4 ± 1.6 kg/m2) consumed three different types of alcohol beverages (beer, shochu, and sake, each with 40 g ethanol) or mineral water with dinner on different days in the hospital. Blood samples were collected before and 1, 2, and 12 h after drinking each beverage, and assessments of physical and emotional state were administered at the same time. In addition, sleep patterns and brain waves were examined using polysomnography. Results. Blood glucose levels at 1 h and the 12-h area under the curve (AUC) value after drinking shochu were significantly lower than that with water and beer. The 12-h blood insulin AUC value after drinking shochu was significantly lower than that with beer. Blood glucose × insulin level at 1 h and the 2-h blood glucose × insulin AUC value with shochu were significantly lower than that with beer. The insulinogenic indexes at 2 h with beer and sake, but not shochu, were significantly higher than that with water. The visual analogue scale scores of physical and emotional state showed that the tipsiness levels with beer, shochu, and sake at 1 h were significantly higher than that with water. These tipsiness levels were maintained at 2 h. The polysomnography showed that the rapid eye movement (REM) sleep latency with shochu and sake were shorter than that with water and beer. Conclusions. Acute consumption of alcohol beverages with a meal resulted in different responses in postprandial glucose and insulin levels as well as REM sleep latency. Alcohol beverage type should be taken into consideration

  18. Chronic glucose infusion causes sustained increases in tubular sodium reabsorption and renal blood flow in dogs.

    Science.gov (United States)

    Brands, Michael W; Bell, Tracy D; Rodriquez, Nancy A; Polavarapu, Praveen; Panteleyev, Dmitriy

    2009-02-01

    This study tested the hypothesis that inducing hyperinsulinemia and hyperglycemia in dogs, by infusing glucose chronically intravenously, would increase tubular sodium reabsorption and cause hypertension. Glucose was infused for 6 days (14 mg.kg(-1).min(-1) iv) in five uninephrectomized (UNX) dogs. Mean arterial pressure (MAP) and renal blood flow (RBF) were measured 18 h/day using DSI pressure units and Transonic flow probes, respectively. Urinary sodium excretion (UNaV) decreased significantly on day 1 and remained decreased over the 6 days, coupled with a significant, sustained increase in RBF, averaging approximately 20% above control on day 6. Glomerular filtration rate and plasma renin activity (PRA) also increased. However, although MAP tended to increase, this was not statistically significant. Therefore, the glucose infusion was repeated in six dogs with 70% surgical reduction in kidney mass (RKM) and high salt intake. Blood glucose and plasma insulin increased similar to the UNX dogs, and there was significant sodium retention, but MAP still did not increase. Interestingly, the increases in PRA and RBF were prevented in the RKM dogs. The decrease in UNaV, increased RBF, and slightly elevated MAP show that glucose infusion in dogs caused a sustained increase in tubular sodium reabsorption by a mechanism independent of pressure natriuresis. The accompanying increase in PRA, together with the failure of either RBF or PRA to increase in the RKM dogs, suggests the site of tubular reabsorption was before the macula densa. However, the volume retention and peripheral edema suggest that systemic vasodilation offsets any potential renal actions to increase MAP in this experimental model in dogs.

  19. Prevalence of glucose-6-phosphate dehydrogenase deficiency and sickle cell trait among blood donors in Riyadh

    Directory of Open Access Journals (Sweden)

    Alabdulaali Mohammed

    2010-01-01

    Full Text Available Background and Aims: Blood donation from glucose-6-phosphate dehydrogenase (G6PD-deficient and sickle cell trait (SCT donors might alter the quality of the donated blood during processing, storage or in the recipient′s circulatory system. The aim of this study was to determine the prevalence of G6PD deficiency and SCT among blood donors coming to King Khalid University Hospital (KKUH in Riyadh. It was also reviewed the benefits and risks of transfusing blood from these blood donors. Materials and Methods: This cross-sectional study was conducted on 1150 blood samples obtained from blood donors that presented to KKUH blood bank during the period April 2006 to May 2006. All samples were tested for Hb-S by solubility test, alkaline gel electrophoresis; and for G6PD deficiency, by fluorescent spot test. Results: Out of the 1150 donors, 23 (2% were diagnosed for SCT, 9 (0.78% for G6PD deficiency and 4 (0.35% for both conditions. Our prevalence of SCT and G6PD deficiency is higher than that of the general population of Riyadh. Conclusion: We recommend to screen all units for G6PD deficiency and sickle cell trait and to defer donations from donors with either of these conditions, unless if needed for special blood group compatibility, platelet apheresis or if these are likely to affect the blood bank inventory. If such blood is to be used, special precautions need to be undertaken to avoid complications in high-risk recipients.

  20. Performance of two updated blood glucose monitoring systems: an evaluation following ISO 15197:2013.

    Science.gov (United States)

    Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Jendrike, Nina; Haug, Cornelia; Freckmann, Guido

    2016-05-01

    Objective For patients with diabetes, regular self-monitoring of blood glucose (SMBG) is essential to ensure adequate glycemic control. Therefore, accurate and reliable blood glucose measurements with SMBG systems are necessary. The international standard ISO 15197 describes requirements for SMBG systems, such as limits within which 95% of glucose results have to fall to reach acceptable system accuracy. The 2013 version of this standard sets higher demands, especially regarding system accuracy, than the currently still valid edition. ISO 15197 can be applied by manufacturers to receive a CE mark for their system. Research design and methods This study was an accuracy evaluation following ISO 15197:2013 section 6.3 of two recently updated SMBG systems (Contour * and Contour TS; Bayer Consumer Care AG, Basel, Switzerland) with an improved algorithm to investigate whether the systems fulfill the requirements of the new standard. For this purpose, capillary blood samples of approximately 100 participants were measured with three test strip lots of both systems and deviations from glucose values obtained with a hexokinase-based comparison method (Cobas Integra † 400 plus; Roche Instrument Center, Rotkreuz, Switzerland) were determined. Percentages of values within the acceptance criteria of ISO 15197:2013 were calculated. This study was registered at clinicaltrials.gov (NCT02358408). Main outcome Both updated systems fulfilled the system accuracy requirements of ISO 15197:2013 as 98.5% to 100% of the results were within the stipulated limits. Furthermore, all results were within the clinically non-critical zones A and B of the consensus error grid for type 1 diabetes. Conclusions The technical improvement of the systems ensured compliance with ISO 15197 in the hands of healthcare professionals even in its more stringent 2013 version. Alternative presentation of system accuracy results in radar plots provides additional information with certain advantages. In addition

  1. Impact of sodium–glucose cotransporter 2 inhibitors on blood pressure

    Science.gov (United States)

    Reed, James W

    2016-01-01

    SGLT2 inhibitors are glucose-lowering agents used to treat type 2 diabetes mellitus (T2DM). These agents target the kidney to promote urinary glucose excretion, resulting in improved blood glucose control. SGLT2-inhibitor therapy is also associated with weight loss and blood pressure (BP) lowering. Hypertension is a common comorbidity in patients with T2DM, and is associated with excess morbidity and mortality. This review summarizes data on the effect of SGLT2 inhibitors marketed in the US (namely canagliflozin, dapagliflozin, or empagliflozin) on BP in patients with T2DM. Boolean searches were conducted that included terms related to BP or hypertension with terms for SGLT2 inhibitors, canagliflozin, dapagliflozin, or empagliflozin using PubMed, Google, and Google Scholar. Data from numerous randomized controlled trials of SGLT2 inhibitors in patients with T2DM demonstrated clinically relevant reductions in both systolic and diastolic BP, assessed via seated office measurements and 24-hour ambulatory BP monitoring. Observed BP lowering was not associated with compensatory increases in heart rate. Circadian BP rhythm was also maintained. The mechanism of SGLT2 inhibitor-associated BP reduction is not fully understood, but is assumed to be related to osmotic diuresis and natriuresis. Other factors that may also contribute to BP reduction include SGLT2 inhibitor-associated decreases in body weight and reduced arterial stiffness. Local inhibition of the renin–angiotensin–aldosterone system secondary to increased delivery of sodium to the juxtaglomerular apparatus during SGLT2 inhibition has also been postulated. Although SGLT2 inhibitors are not indicated as BP-lowering agents, the modest decreases in systolic and diastolic BP observed with SGLT2 inhibitors may provide an extra clinical advantage for the majority of patients with T2DM, in addition to improving blood glucose control. PMID:27822054

  2. A novel adaptive basal therapy based on the value and rate of change of blood glucose.

    Science.gov (United States)

    Wang, Youqing; Percival, Matthew W; Dassau, Eyal; Zisser, Howard C; Jovanovic, Lois; Doyle, Francis J

    2009-09-01

    Modern insulin pump therapy for type 1 diabetes mellitus offers the freedom to program several basal profiles that may accommodate diurnal ariability in insulin sensitivity and activity level. However, these basal profiles do not change even if a pending hypoglycemic or hyperglycemic event is foreseen. New insulin pumps could receive a direct feed of glucose values from a continuous glucose monitoring (CGM) system and could enable dynamic basal adaptation to improve glycemic control. The proposed method is a two-step procedure. After the design of an initial basal profile, an adaptation of the basal rate is suggested as a gain multiplier based on the current CGM glucose value and its rate of change (ROC). Taking the glucose value and its ROC as axes, a two-dimensional plane is divided into a nine-zone mosaic, where each zone is given a predefined basal multiplier; for example, a basal multiplier of zero indicates a recommendation to shut off the pump. The proposed therapy was evaluated on 20 in silico subjects (ten adults and ten adolescents) in the Food and Drug Administration-approved UVa/Padova simulator. Compared with conventional basal therapy, the proposed basal adjustment improved the percentage of glucose levels that stayed in the range of 60-180 mg/dl for all 20 subjects. In addition, the adaptive basal therapy reduced the average blood glucose index values. The proposed therapy provides the flexibility to account for insulin sensitivity variations that may result from stress and/or physical activities. Because of its simplicity, the proposed method could be embedded in a chip in a future artificial pancreatic beta cell or used in a "smart" insulin pump. 2009 Diabetes Technology Society.

  3. 糖尿病血糖精准监测%Accurate monitoring of blood glucose in diabetic patients

    Institute of Scientific and Technical Information of China (English)

    郭淑芹

    2016-01-01

    ABSTRACT:Precision medicine is the medical model proposed in the era of big data,diabetes blood glucose monitoring is also affected by the impact of precision thinking.Based on adequate assessment of various means of monitoring blood glucose,blood glucose monitoring is recommended from the self monitoring of the"point"blood sugar,to dynamically monitor the blood glucose change curve,and then to reflect the total blood glucose level of three months of glycosylated hemoglobin under the present stage.Future artificial pancreas technology will achieve accurate blood glucose management.%精准医学是在大数据时代提出的医疗模式,糖尿病血糖监测也受到精准思维的影响。充分评估血糖监测手段精准性基础上,现阶段血糖监测推荐从自我监测的“点”血糖,到动态监测血糖变化“曲线”,再到反映3个月总体血糖水平的糖化血红蛋白。未来人工胰腺技术将实现精准的血糖管理。

  4. PET imaging of blood flow and glucose metabolism in localized musculoskeletal tumors of the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Lindholm, Paula, E-mail: paula.lindholm@tyks.f [Department of Oncology and Radiotherapy, Turku University Hospital, Turku FI-20521 (Finland); Turku PET Centre, Turku (Finland); Sutinen, Eija [Department of Oncology and Radiotherapy, Turku University Hospital, Turku FI-20521 (Finland); Turku PET Centre, Turku (Finland); Oikonen, Vesa [Turku PET Centre, Turku (Finland); Mattila, Kimmo [Department of Radiology, Turku University Hospital, Turku FI-20521 (Finland); Tarkkanen, Maija [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland); Kallajoki, Markku [Department of Pathology, Turku University Hospital, Turku FI-20521 (Finland); Aro, Hannu [Department of Orthopaedic Surgery, Turku University Hospital, Turku FI-20521 (Finland); Boehling, Tom [Department of Pathology, Helsinki University Central Hospital, Helsinki (Finland); Kivioja, Aarne [Department of Orthopaedic Surgery, Helsinki University Central Hospital, Helsinki, FI-00029 (Finland); Elomaa, Inkeri [Department of Oncology, Helsinki University Central Hospital, Helsinki (Finland); Minn, Heikki [Department of Oncology and Radiotherapy, Turku University Hospital, Turku FI-20521 (Finland); Turku PET Centre, Turku (Finland)

    2011-02-15

    Introduction: Little is known about blood flow in sarcomas. Our purpose was to study glucose metabolism and blood flow in untreated localized musculoskeletal tumors of the extremities using [{sup 18}F]fluorodeoxyglucose (FDG), oxygen-15 labeled water ([15O]H{sub 2}O) and positron emission tomography (PET). Methods: Six patients with high-grade osteosarcoma (OS), two with soft-tissue sarcoma (STS) and one with aneurysmal bone cyst had PET studies with [15O]H{sub 2}O and FDG. Arterial blood sampling and autoradiography calculation method were used to define blood flow as milliliters per 100 g times minutes. Tumor FDG uptake was measured as standardized uptake values (SUVs) and regional metabolic rates for FDG (rMRFDG). Two patients also had FDG PET studies during (one patient) and after (two patients) preoperative chemotherapy. All patients underwent dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). The PET findings were compared with the clinical follow-up data and results of DCE-MRI. Results: Blood flow in bone tumors was 31.7-75.2 ml/(100 gxmin) and in STS 9.0-45.9 ml/(100 gxmin). [{sup 18}F]-Fluorodeoxyglucose uptake and rMRFDG in untreated bone tumors were 5.4-18.4 and 10.9-57.4 {mu}mol/100 g/min, respectively. [{sup 18}F]-Fluorodeoxyglucose uptake and rMRFDG in STS were 2.6-11.5 and 5.6-32.2 {mu}mol/100 g/min, respectively. Four of five sarcomas with SUV>9.0 have already relapsed. High blood flow in untreated OS was related to long overall survival, while the predictive power of glucose metabolism was less apparent. Good histopathological response to therapy was not associated with long survival. Conclusions: Measurement of blood flow in musculoskeletal tumors appears to be feasible by PET and [{sup 15}O]H{sub 2}O. The influence of tumor blood flow and glucose metabolism on the final outcome in sarcoma is variable and needs further research.

  5. Modification of corporal weight, body fat distribution, blood lipids and glucose levels in oral contraceptive users.

    Science.gov (United States)

    Carranza-Lira, S; Bueno Fontal, J P

    2000-01-01

    The association between oral contraceptives and the modification of corporal weight and body fat distribution is controversial. The characteristics of the menstrual cycle, lipids and glucose levels were also analyzed. Thirty women who received ethinylestradiol 0.035 mg and norethindrone 0.400 mg for one year were studied. The following variables were analyzed every 3 months: weight, body mass index (BMI), hip perimeter, waist perimeter, waist-hip ratio (WHR), duration of menstrual cycle, quantity of uterine bleeding, as well as blood levels of cholesterol, triglycerides and glucose. Waist and hip perimeters increased during the third evaluation; as well as the BMI starting from the second evaluation. The triglycerides levels rose from the first evaluation. No modifications were found in the WHR, glucose and cholesterol levels and the duration of the menstrual cycle, but the quantity of uterine bleeding decreased from the third month. The oral contraceptive significantly increased BMI and triglycerides level, but no changes were detected in body fat distribution, cholesterol and glucose levels. Uterine bleeding decreased from the first evaluation.

  6. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  7. Progressive artificial endocrine pancreas: The era of novel perioperative blood glucose control for surgery.

    Science.gov (United States)

    Tsukamoto, Yuuki; Okabayashi, Takehiro; Hanazaki, Kazuhiro

    2011-10-01

    Strict glycemic control needs to be maintained in critically ill surgical patients to reduce the mortality and morbidity due to hyperglycemia and associated infection. However, conventional intensive insulin therapy (IIT), which consists of intermittent blood glucose measurement and manually controlled infusions of insulin, tends to induce hypoglycemia and glucose variability. Many randomized clinical trials have been conducted to improve the efficacy of IIT, although some of these were stopped owing to frequent hypoglycemia. In pursuing safe and strict glycemic control for critically ill surgical patients, we found that a closed-loop glycemic control system was able to maintain appropriate blood glucose levels without hypoglycemia in more than 400 clinical cases. Considering the need for the perioperative and intensive care environment, a well-established artificial pancreas was modified into a new closed-loop glycemic control system, called the progressive artificial pancreas. The new device is slim in shape and shows clinical compatibility with the conventional artificial pancreas. We herein review this new closed-loop glycemic control system and the expectations for its future application in critically ill surgical patients.

  8. Profile of blood glucose and ultrastucture of beta cells pancreatic islet in alloxan compound induced rats

    Directory of Open Access Journals (Sweden)

    I Nyoman Suarsana

    2010-06-01

    Full Text Available Diabetes is marked by elevated levels of blood glucose, and progressive changes of the structure of pancreatic islet histopathology. The objective of this research was to analyse the glucose level and histophatological feature in pancreatic islet in alloxan compound induced rats. A total of ten male Spraque Dawley rats of 2 months old were used in this study. The rats were divided into two groups: (1 negative control group (K-, and (2 positif induced alloxan group (diabetic group =DM. The rats were induced by a single dose intraperitonial injection of alloxan compound 120 mg/kg of body weight. The treatment was conducted for 28 days. Blood glucose levels of rats were analysed at 0, 4, 7, 14, 21, and 28 days following treatment. At the end of the experiment, rats were sacrificed by cervical dislocation. Pancreas was collected for analysis of histopathological study by Immunohistochemical technique, and ultrastructural study using transmission electron microscope (TEM. The result showed that Langerhans islet of diabetic rat (rat of DM group showed a marked reduction of size, number of Langerhans islet of diabetic rat decrease, and characterized by hyperglycemic condition. By using TEM, beta cells of DM group showed the rupture of mitochondrial membrane, the lost of cisternal structure of inner membrane of mitocondria, reduction of insulin secretory granules, linkage between cells acinar with free Langerhans islet, and the caryopicnotic of nucleus.

  9. The efficacy of karkadeh tea in controlling post-prandial blood glucose levels

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Cooper, Ross Gordon; Suliman, Moustafa Ahmed

    2009-01-01

    Problem Statement: Increasing interest from the general public to use herbal remedies, exposes a considerable need to document ancient medical practices, as well as to investigate the efficacy of "ancient" compounds currently reputed to have medicinal benefits for such diseases as diabetes and ob...... of slowing the rate of rise in blood glucose following consumption of a high glycemic index food, but that ultimately it induces a greater degreee of glucose absorption cf. other types of imbibed fluids.......Problem Statement: Increasing interest from the general public to use herbal remedies, exposes a considerable need to document ancient medical practices, as well as to investigate the efficacy of "ancient" compounds currently reputed to have medicinal benefits for such diseases as diabetes......, a slower rise to maximum levels and a greater Area Under the Curve (AUC) in terms of blood glucose was noted for the karkadeh tea plus a high glycemic index food cf. that of water imbibition with an identical high glycemic food. Conclusions/Recommendations: Karkadeh tea appears to have an efffect in terms...

  10. The effect of moderate glycemic energy bar consumption on blood glucose and mood in dancers.

    Science.gov (United States)

    Brown, Derrick; Wyon, Matthew

    2014-03-01

    Ingesting quality carbohydrates has been shown to be essential for dancers. Given that most dance classes take place in the morning, it has been recommended that dancers eat a well-balanced breakfast containing carbohydrates, fats, and protein as a means of fuelling this activity. The aim of this study was to determine the effect of a moderate glycemic index energy (MGI) bar or a fasting condition on dancers' blood glucose levels and perceived pleasure-displeasure response during the first dance class of the day. In a randomized counterbalanced design, 10 female preprofessional dance students took their regular scheduled contemporary dance class, on four separate occasions. On each occasion, they consumed either a commercially prepared carbohydrate (CHO)-dense energy bar (47.3 g CHO) or water (FAST). Plasma glucose responses and pleasure-displeasure affect were measured before and at two time points during the class. Dancers who consumed the MGI bar had significantly greater peak blood glucose levels at all time points than those who fasted (pdance class. Further, we conclude that skipping breakfast can have an unfavorable effect on the pleasure-displeasure state of dancers. These findings highlight the impact of breakfast on how one feels, as well as the physiological and metabolic benefits of CHO as an exogenous energy source in dancers.

  11. Effect of whey on blood glucose and insulin responses to composite breakfast and lunch meals in type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Frid, Anders H; Nilsson, Mikael; Holst, Jens Juul

    2005-01-01

    glycemic index (GI) with whey proteins may increase insulin secretion and improve blood glucose control in type 2 diabetic subjects. DESIGN: Fourteen diet-treated subjects with type 2 diabetes were served a high-GI breakfast (white bread) and subsequent high-GI lunch (mashed potatoes with meatballs...... insulin release and reduces postprandial blood glucose excursion after a lunch meal consisting of mashed potatoes and meatballs in type 2 diabetic subjects....

  12. Risk factors for unstable blood glucose level: integrative review of the risk factors related to the nursing diagnosis

    OpenAIRE

    Teixeira,Andressa Magalhães; Tsukamoto, Rosangela; Lopes,Camila Takáo; Silva, Rita de Cassia Gengo e

    2017-01-01

    ABSTRACT Objective: to identify evidence in the literature on the possible risk factors for the risk of unstable blood glucose diagnosis in individuals with type 2 diabetes mellitus, and to compare them with the risk factors described by NANDA International. Method: an integrative literature review guided by the question: what are the risk factors for unstable blood glucose level in people with type 2 diabetes mellitus? Primary studies were included whose outcomes were variations in glycemi...

  13. Self-monitoring of blood glucose is associated with problem-solving skills in hyperglycemia and hypoglycemia.

    Science.gov (United States)

    Wang, Jing; Zgibor, Janice; Matthews, Judith T; Charron-Prochownik, Denise; Sereika, Susan M; Siminerio, Linda

    2012-01-01

    The purpose of this study was to examine the association between self-monitoring of blood glucose (SMBG) and problem-solving skills in response to detected hyperglycemia and hypoglycemia among patients with type 2 diabetes. Data were obtained from the American Association of Diabetes Educators Outcome System, implemented in 8 diabetes self-management education programs in western Pennsylvania. SMBG was measured by asking patients how often they checked, missed checking, or checked blood glucose later than planned. Problem-solving skill was measured by asking how often they modified their behaviors after detecting high or low blood glucose. Most patients checked their blood glucose at least once per day. However, when blood glucose was high or low, many of them reported doing nothing, and only some of them resolved the problem. There were significant associations between self-monitoring of blood glucose and problem-solving skills for hyperglycemia and hypoglycemia, after controlling for age, gender, ethnicity, education, and time since diagnosis. Patients reported poor problem-solving skills when detecting hyperglycemia and hypoglycemia via SMBG. Patients need to learn problem-solving skills along with SMBG training to achieve glycemic control.

  14. Oral dehydroepiandrosterone (DHEA) replacement in older adults: effects on central adiposity, glucose metabolism, and blood lipids

    Science.gov (United States)

    Jankowski, Catherine M.; Gozansky, Wendolyn S.; Van Pelt, Rachael E.; Wolfe, Pamela; Schwartz, Robert S.; Kohrt, Wendy M.

    2011-01-01

    Objective The aim was to determine the effects of dehydroepiandrosterone (DHEA) therapy on changes in central adiposity, insulin action, and blood lipids. Many of the actions of DHEA in humans are thought to be mediated through its conversion to sex hormones, which are modulators of adiposity, muscularity, and insulin sensitivity. The effects of DHEA replacement on regional tissue composition, glucose metabolism, and blood lipid profile in older adults have been inconsistent. Design a randomized, double-blinded, placebo-controlled trial. The intervention was oral DHEA 50 mg/d or placebo for 12 months. Participants 58 women and 61 men, aged 60–88 yr, with low serum DHEA sulfate (DHEAS) levels at study entry. Measurements Computed tomography measures of abdominal fat areas, thigh muscle and fat areas, DXA-derived trunk fat mass, serum glucose and insulin responses to an oral glucose challenge, and fasted serum total cholesterol, HDL-cholesterol, LDL-cholesterol, and triglycerides were assessed before and after the intervention. Results There were no significant (P > 0.05) differences between the DHEA and placebo groups in the changes in regional tissue composition or glucose metabolism. HDL-cholesterol (P =0.01) and fasted triglycerides (P =0.02) decreased in women and men taking DHEA. Conclusion Restoring serum DHEAS levels in older adults to young adult levels for 1 year does not appear to reduce central adiposity or improve insulin action. The benefit of DHEA on decreasing serum triglycerides must be weighed against the HDL-lowering effect. PMID:21521341

  15. Facts and artefacts regarding correlation between skin electrical impedance spectroscopy (EIS) and blood glucose

    Science.gov (United States)

    Ollmar, Stig; Nicander, Ingrid; Åberg, Peter; Bolinder, Jan

    2013-04-01

    Earlier observations on possible co-variation between skin EIS and blood glucose prompted us to map and include other factors at play in the predictive model. Skin pH would be one such factor. A cohort of 20 diabetics was investigated, taking around 30 measurements spread over each of two different days 2-21 days apart. Each measurement comprises skin EIT in the frequency range 1kHz to 2.5MHz, skin pH, and immediately evaluated blood samples. There is a co-variation for some, but not all, test persons. The relationship gets stronger on the group level by adding pH-information, but is still poor or non-existent for some test persons. Non-invasive EIS measurements on skin is influenced by skin hydration, blood glucose, skin pH, body location, season, environmental factors, and variables not yet understood. Since impedance related parameters are used to estimate skin hydration, users of such devices should be aware that skin pH may influence as much as the water content of the stratum corneum.

  16. Association between DNA Methylation in Whole Blood and Measures of Glucose Metabolism: KORA F4 Study.

    Directory of Open Access Journals (Sweden)

    Jennifer Kriebel

    Full Text Available Epigenetic regulation has been postulated to affect glucose metabolism, insulin sensitivity and the risk of type 2 diabetes. Therefore, we performed an epigenome-wide association study for measures of glucose metabolism in whole blood samples of the population-based Cooperative Health Research in the Region of Augsburg F4 study using the Illumina HumanMethylation 450 BeadChip. We identified a total of 31 CpG sites where methylation level was associated with measures of glucose metabolism after adjustment for age, sex, smoking, and estimated white blood cell proportions and correction for multiple testing using the Benjamini-Hochberg (B-H method (four for fasting glucose, seven for fasting insulin, 25 for homeostasis model assessment-insulin resistance [HOMA-IR]; B-H-adjusted p-values between 9.2x10(-5 and 0.047. In addition, DNA methylation at cg06500161 (annotated to ABCG1 was associated with all the aforementioned phenotypes and 2-hour glucose (B-H-adjusted p-values between 9.2x10(-5 and 3.0x10(-3. Methylation status of additional three CpG sites showed an association with fasting insulin only after additional adjustment for body mass index (BMI (B-H-adjusted p-values = 0.047. Overall, effect strengths were reduced by around 30% after additional adjustment for BMI, suggesting that this variable has an influence on the investigated phenotypes. Furthermore, we found significant associations between methylation status of 21 of the aforementioned CpG sites and 2-hour insulin in a subset of samples with seven significant associations persisting after additional adjustment for BMI. In a subset of 533 participants, methylation of the CpG site cg06500161 (ABCG1 was inversely associated with ABCG1 gene expression (B-H-adjusted p-value = 1.5x10(-9. Additionally, we observed an enrichment of the top 1,000 CpG sites for diabetes-related canonical pathways using Ingenuity Pathway Analysis. In conclusion, our study indicates that DNA methylation and

  17. Association between DNA Methylation in Whole Blood and Measures of Glucose Metabolism: KORA F4 Study.

    Science.gov (United States)

    Kriebel, Jennifer; Herder, Christian; Rathmann, Wolfgang; Wahl, Simone; Kunze, Sonja; Molnos, Sophie; Volkova, Nadezda; Schramm, Katharina; Carstensen-Kirberg, Maren; Waldenberger, Melanie; Gieger, Christian; Peters, Annette; Illig, Thomas; Prokisch, Holger; Roden, Michael; Grallert, Harald

    2016-01-01

    Epigenetic regulation has been postulated to affect glucose metabolism, insulin sensitivity and the risk of type 2 diabetes. Therefore, we performed an epigenome-wide association study for measures of glucose metabolism in whole blood samples of the population-based Cooperative Health Research in the Region of Augsburg F4 study using the Illumina HumanMethylation 450 BeadChip. We identified a total of 31 CpG sites where methylation level was associated with measures of glucose metabolism after adjustment for age, sex, smoking, and estimated white blood cell proportions and correction for multiple testing using the Benjamini-Hochberg (B-H) method (four for fasting glucose, seven for fasting insulin, 25 for homeostasis model assessment-insulin resistance [HOMA-IR]; B-H-adjusted p-values between 9.2x10(-5) and 0.047). In addition, DNA methylation at cg06500161 (annotated to ABCG1) was associated with all the aforementioned phenotypes and 2-hour glucose (B-H-adjusted p-values between 9.2x10(-5) and 3.0x10(-3)). Methylation status of additional three CpG sites showed an association with fasting insulin only after additional adjustment for body mass index (BMI) (B-H-adjusted p-values = 0.047). Overall, effect strengths were reduced by around 30% after additional adjustment for BMI, suggesting that this variable has an influence on the investigated phenotypes. Furthermore, we found significant associations between methylation status of 21 of the aforementioned CpG sites and 2-hour insulin in a subset of samples with seven significant associations persisting after additional adjustment for BMI. In a subset of 533 participants, methylation of the CpG site cg06500161 (ABCG1) was inversely associated with ABCG1 gene expression (B-H-adjusted p-value = 1.5x10(-9)). Additionally, we observed an enrichment of the top 1,000 CpG sites for diabetes-related canonical pathways using Ingenuity Pathway Analysis. In conclusion, our study indicates that DNA methylation and diabetes

  18. Development and Testing of a Plastic Optical Fiber Grating Biosensor for Detection of Glucose in the Blood

    Science.gov (United States)

    Yunianto, M.; Eka, D.; Permata, A. N.; Ariningrum, D.; Wahyuningsih, S.; Marzuki, A.

    2017-02-01

    The objective of this study is to detect glucose content in human blood serum using optical fiber grating with LED wavelength corresponding to the absorption of glucose content in blood serum. The testing used a UV-Vis spectrometer and Rays spectrometers, in which in the ray spectrometer it was used optical fiber biosensor using optical fiber grating. The result obtained is the typical peak of glucose absorption in UV-Vis at 581 nm wavelength and rays spectrometer on green LED at 514.2 nm wavelength with linear regression result by 0.97 and 0.94, respectively.

  19. Alternate Immersion in an External Glucose Solution Differentially Affects Blood Sugar Values in Older Versus Younger Zebrafish Adults.

    Science.gov (United States)

    Connaughton, Victoria P; Baker, Cassandra; Fonde, Lauren; Gerardi, Emily; Slack, Carly

    2016-04-01

    Recently, zebrafish have been used to examine hyperglycemia-induced complications (retinopathy and neuropathy), as would occur in individuals with diabetes. Current models to induce hyperglycemia in zebrafish include glucose immersion and streptozotocin injections. Both are effective, although neither is reported to elevate blood sugar values for more than 1 month. In this article, we report differences in hyperglycemia induction and maintenance in young (4-11 months) versus old (1-3 years) zebrafish adults. In particular, older fish immersed in an alternating constant external glucose solution (2%) for 2 months displayed elevated blood glucose levels for the entire experimental duration. In contrast, younger adults displayed only transient hyperglycemia, suggesting the fish were acclimating to the glucose exposure protocol. However, modifying the immersion protocol to include a stepwise increasing glucose concentration (from 1% → 2%→3%) resulted in maintained hyperglycemia in younger zebrafish adults for up to 2 months. Glucose-exposed younger fish collected after 8 weeks of exposure also displayed a significant decrease in wet weight. Taken together, these data suggest different susceptibilities to hyperglycemia in older and younger fish and that stepwise increasing glucose concentrations of 1% are required for maintenance of hyperglycemia in younger adults, with higher concentrations of glucose resulting in greater increases in blood sugar values.

  20. Investigation of the Blood Glucose Lowering Potential of the Jamaican Momordica charantia (Cerasee) Fruit in Sprague-Dawley Rats

    Science.gov (United States)

    Burnett, A; McKoy, M-L; Singh, P

    2015-01-01

    ABSTRACT The Momordica charantia (MC) fruit has been documented to possess antidiabetic properties. However, these studies were not without controversy surrounding the blood glucose-lowering ability and the mechanism of action in diabetes therapy. In an effort to evaluate such claims in the Jamaican MC species known as cerasee, aqueous extracts of the unripe fruit were studied in normal and diabetic rats. Normal male Sprague-Dawley rats were divided into groups (n = 6) orally administered distilled water, 10% dimethyl sulfoxide (DMSO) solution, the aqueous extract (400 mg/kg body weight) and glibenclamide (15 mg/kg body weight), respectively prior to assessment of fasting blood glucose (FBG) concentration. The oral glucose tolerance test (OGTT) was conducted in normoglycaemic rats orally administered distilled water, 10% DMSO solution, glibenclamide (15 mg/kg body weight) or aqueous extracts of the fruit (200 and 400 mg/kg body weight). Blood glucose concentration was also monitored in streptozotocin-induced diabetic rats administered the aqueous extract (250 mg/kg body weight) or water vehicle after an overnight fast. The aqueous extracts showed no hypoglycaemic or antidiabetic activity. However, the administration of the aqueous extracts (200 and 400 mg/kg body weight) resulted in significant improvement in glucose tolerance of glucose-primed normoglycaemic rats during the OGTT. These data suggest that the glucose-lowering mechanism of the Jamaican MC fruit species likely involves altered glucose absorption across the gastrointestinal tract. PMID:26624580

  1. Changes in blood glucose and salivary cortisol are not necessary for arousal to enhance memory in young or older adults.

    Science.gov (United States)

    Gore, Jane B; Krebs, Desiree L; Parent, Marise B

    2006-06-01

    Emotional arousal enhances memory, and this memory-enhancing effect may involve neurochemicals released by arousal, such as glucose and cortisol. Physiological consequences of arousal change with age, and these changes may contribute to age-related memory decline. The present study examined whether emotionally arousing pictures would affect glucose and cortisol levels and enhance memory in young and older adults. Blood glucose and salivary cortisol were measured once before and six times after young and old adults viewed either 60 highly arousing or 60 relatively neutral pictures. Recall for the stimuli was measured 75 min later. The results indicated that recall was impaired in older adults. Arousal as measured by self-report enhanced recall in both young and older adults. However, arousal did not affect glucose or cortisol levels in either group. These findings demonstrate that changes in blood glucose or salivary cortisol levels are not necessary for arousal to enhance memory.

  2. Regional cerebral blood flow and glucose metabolism following transient forebrain ischemia.

    Science.gov (United States)

    Pulsinelli, W A; Levy, D E; Duffy, T E

    1982-05-01

    Progressive brain damage after transient cerebral ischemia may be related to changes in postischemic cerebral blood flow and metabolism. Regional cerebral blood flow (rCBF) and cerebral glucose utilization (rCGU) were measured in adult rats prior to, during (only rCBF), and serially after transient forebrain ischemia. Animals were subjected to 30 minutes of forebrain ischemia by occluding both common carotid arteries 24 hours after cauterizing the vertebral arteries. Regional CBF was measured by the indicator-fractionation technique using 4-iodo-[14C]-antipyrine. Regional CGU was measured by the 2-[14C]deoxyglucose method. The results were correlated with the distribution and progression of ischemic neuronal damage in animals subjected to an identical ischemic insult. Cerebral blood flow to forebrain after 30 minutes of moderate to severe ischemia (less than 10% control CBF) was characterized by 5 to 15 minutes of hyperemia; rCBF then fell below normal and remained low for as long as 24 hours. Post-ischemic glucose utilization in the forebrain, except in the hippocampus, was depressed below control values at 1 hour and either remained low (neocortex, striatum) or gradually rose to normal (white matter) by 48 hours. In the hippocampus, glucose utilization equaled the control value at 1 hour and fell below control between 24 and 48 hours. The appearance of moderate to severe morphological damage in striatum and hippocampus coincided with a late rise of rCBF above normal and with a fall of rCGU; the late depression of rCGU was usually preceded by a period during which metabolism was increased relative to adjacent tissue. Further refinement of these studies may help identify salvageable brain after ischemia and define ways to manipulate CBF and metabolism in the treatment of stroke.

  3. Self-monitoring of blood glucose in noninsulin-treated type 2 diabetes: an overview

    Directory of Open Access Journals (Sweden)

    Nanne Kleefstra

    2009-09-01

    Full Text Available Nanne Kleefstra1, Johanna Hortensius1, Kornelis JJ van Hateren1, Susan JJ Logtenberg1, Sebastiaan T Houweling2, Rijk OB Gans3, Henk JG Bilo11Diabetes Centre, Isala Clinics, Zwolle, The Netherlands; 2Langerhans Medical Research Group, The Netherlands; 3Department of Internal Medicine, University Medical Center Groningen, Groningen, The NetherlandsIntroduction: The effectiveness of self-monitoring of blood glucose (SMBG in noninsulin-treated patients with type 2 diabetes (T2DM remains unclear. We aimed to review the trials investigating the effects of SMBG in this population.Methods: Medline was searched until June 29, 2009. Randomized controlled trials (RCTs of at least 12 weeks’ duration were included. Data on the following aspects were gathered: patient and study characteristics, effects on HbA1c, quality of life and treatment satisfaction, and methodological quality.Results: The search revealed 9 original RCTs. These studies were very heterogeneous, and 5 were classified as of high quality. The studies with the best methodology did not show an effect of SMBG on HbA1c, the studies with the worst methodological quality did. Two out of the 4 studies that assessed quality of life showed a significant change in favor of the control group, 1 study showed a significant change in favor of SMBG.Discussion and conclusion: We found an inverse relation between study quality and efficacy of SMBG. At this moment, there is no basis for general use of SMBG in noninsulin-treated T2DM patients.Keywords: blood glucose self-monitoring, diabetes mellitus, type 2, blood glucose, hemoglobin A, glycosylated

  4. FibroMeters:诊断肝纤维化的血液学检测指标组合%FibroMeters:a family of blood tests for liver fibrosis

    Institute of Scientific and Technical Information of China (English)

    Paul Calès; Jér(o)me Boursier; Frédéric Oberti; Isabelle Hubert; Yves Gallois; Marie Christine Rousselet; Valérie Moal; Laurent Macchi; Alain Chevailler

    2013-01-01

    FibroMeters are blood tests for liver fibrosis with several specificities:three main diagnostic targets (significant fibrosis,cirrhosis and the area of fibrosis),adaptation to specific causes,and secured results by an expert system.Thus,there are 6different main FibroMeters:one for staging and one for quantitation of liver fibrosis in each of the three main causes of chronic liver diseases--chronic viral hepatitis,alcoholic liver disease and non-alcoholic fatty liver disease (NAFLD).FibroMeters display a very high overall diagnostic accuracy and are the only tests to correctly classify 100% of HCV patients without fibrosis or with cirrhosis when the reference is significant fibrosis by liver biopsy.Considering applicability,FibroMeters have 90% predictive values in a higher proportion of patients; a 87% correct classification is available in HCV patients by using a detailed fibrosis classification including 7 classes; in real life conditions,the reproducibility of FibroMeters is higher than that of liver biopsy or ultrasonographic elastometry.FibroMeters are robust tests with the most stable diagnostic performance in different centers.There are optional tests:a CirrhoMeter dedicated to cirrhosis provides a diagnostic accuracy of 93% [area under the receiver operating characteristic curve (AUROC):0.92] and a 100% positive predictive value for diagnosis of HCV cirrhosis in a patient subset; QuantiMeter for the area of fibrosis,the only direct non-invasive quantitative measurement of liver fibrosis,might be especially useful to follow-up cirrhosis due to its correlation with clinical events.Other causes have been investigated:FibroMeters display a high diagnostic accuracy in HBV or HIV co-infected patients; FibroMeters specific for alcoholic liver disease or NAFLD have a high diagnostic accuracy (AUROC:0.96and 0.94,respectively,for significant fibrosis).%FibroMeters是具有多项特异性的诊断肝纤维化的血液学检测指标组合,其3个主要诊

  5. Variability of blood pressure and blood glucose during perioperative period for patients with secondary neovascular glaucoma after silicone oil removed in PDR

    Directory of Open Access Journals (Sweden)

    Fu-Lin Gao

    2015-06-01

    Full Text Available AIM:To research blood pressure and blood glucose variability during peroperative period for patients with secondary neovasular glaucoma(NVGafter silicone oil removed in proliferative diabetic retinaopathy(PDR.METHODS: Totally, 271 patients(271 eyesundergone surgery of vitrectomy and silicon-oil tamponade combined with cataract were respective analyzed. Fourteen patients(14 eyeswith secondary NVG after silicon oil removed and randomly controlled group of no NVG according with ages, operation method in the same time were studied. The blood pressure and blood glucose variability during peroperative period was analyzed, and did comparison after excluded contralateral eye. The complications of 271 patients were surveyed in following-up period 1~12mo. The incidence of NVG, the time, blood pressure, blood glucose and glycated hemoglobin(Hbc%variability during peroperative period was statisticed and compared by software of SPSS 11.0.RESULTS: Fourteen eyes(5.2%of 271 cases was with secondary NVG(female: 4 eyes, 28.6%; male: 10 eyes, 71.4%, average ages was 57.07 years(49~68 years. NVG presented in the 107~ 135d after vitrectomy and 7~45d(average 31.78dafter silicon-oil removed. Diabetes mellitus was 10~15(average 13.2a. In NVG group, the variability of blood glucose was 4.0~10.2mmol/L(mean 8.52±3.24mmol/L, variable coefficient was 0.48. In NNVG group, the variability of blood glucose was 5.0~8.2mmol/L(mean 7.22±0.24mmol/L, variable coefficient was 0.43. It was significantly difference in comparison in variable coefficient(PPPPCONCLUSION: There are significant variability on fasting blood glucose, daytime SBP and night DBP during perioperative in PDR patients with secondary NVG. It might be occurred 1wk after silicone oil removal surgery.

  6. The Influence of Eleutheroside on Blood Glucose and Blood Lipid of D-Galactose-Induce Rats through Inhibiting Blood Superoxide Dismutase Activities

    Directory of Open Access Journals (Sweden)

    Ping Yang

    2013-07-01

    Full Text Available The present study aims at evaluation mechanisms of natural plant eleutheroside extracts for ameliorating the blood lipid and blood glucose. The eleutherosides derived from the roots of eleutheroccus senticosus and is purported to behave as an “adaptogen”, we assessed effects of eleutheroside at doses of 3.6, 7.2 and 14.4 g/(kg day on SD rats injected daily with D-gal (50 mg/(kg day. Eleutheroside-fed rats showed higher the level HDL-C, decrease the level of HCT, TG, TC, LDL-C compared with D-gal-treated rats. We further examined the mechanisms involved in effects of 3.63.6, 7.2 and 14.4 g/(kg day on rat blood. In summary, eleutheroside significantly increased Superoxide Dismutase (SOD activity and decreased the Malondialdehyde (MDA level.

  7. Markers of glycemic control in the mouse: comparisons of 6-h- and overnight-fasted blood glucoses to Hb A1c

    OpenAIRE

    Han, Byoung Geun; Hao, Chuan-Ming; Elena E. Tchekneva; Wang, Ying-Ying; Lee, Chieh Allen; Ebrahim, Benyamin; Raymond C Harris; Kern, Timothy S.; Wasserman, David H.; Breyer, Matthew D; Qi, Zhonghua

    2008-01-01

    The present studies examined the relationship between fasting blood glucose and Hb A1c in C57BL/6J, DBA/2J, and KK/HlJ mice with and without diabetes mellitus. Daily averaged blood glucose levels based on continuous glucose monitoring and effects of 6-h vs. overnight fasting on blood glucose were determined. Daily averaged blood glucose levels were highly correlated with Hb A1c, as determined with a hand-held automated device using an immunodetection method. R2 values were 0.90, 0.95, and 0.9...

  8. An assessment of morphometric indices, blood chemistry variables and an energy meter as indicators of the whole body lipid content in Micropterus dolomieu, Sander vitreus and Ictalurus punctatus

    Science.gov (United States)

    Mesa, Matthew G.; Rose, Brien P.

    2015-01-01

    The effectiveness of several non-lethal techniques as indicators of total lipid content in smallmouth bass Micropterus dolomieu, walleye Sander vitreus and channel catfish Ictalurus punctatus was investigated. The techniques included (1) the Fulton and relative condition factors, (2) relative mass, (3) plasma indicators of nutritional status (alkaline phosphatase, calcium, cholesterol, protein, triglycerides and glucose) and (4) readings from a hand-held, microwave energy meter. Although simple linear regression analysis showed that lipid content was significantly correlated with several predictor variables in each species, the r2 values for the relations ranged from 0·17 to 0·50 and no single approach was consistent for all species. Only one model, between energy-meter readings and lipid content in I. punctatus, had an r2 value (0·83) high enough to justify using it as a predictive tool. Results indicate that no single variable was an accurate and reliable indicator of whole body lipid content in these fishes, except the energy meter for I. punctatus.

  9. Diabetes Technology: Markers, Monitoring, Assessment, and Control of Blood Glucose Fluctuations in Diabetes

    Directory of Open Access Journals (Sweden)

    Boris P. Kovatchev

    2012-01-01

    Full Text Available People with diabetes face a life-long optimization problem: to maintain strict glycemic control without increasing their risk for hypoglycemia. Since the discovery of insulin in 1921, the external regulation of diabetes by engineering means has became a hallmark of this optimization. Diabetes technology has progressed remarkably over the past 50 years—a progress that includes the development of markers for diabetes control, sophisticated monitoring techniques, mathematical models, assessment procedures, and control algorithms. Continuous glucose monitoring (CGM was introduced in 1999 and has evolved from means for retroactive review of blood glucose profiles to versatile reliable devices, which monitor the course of glucose fluctuations in real time and provide interactive feedback to the patient. Technology integrating CGM with insulin pumps is now available, opening the field for automated closed-loop control, known as the artificial pancreas. Following a number of in-clinic trials, the quest for a wearable ambulatory artificial pancreas is under way, with a first prototype tested in outpatient setting during the past year. This paper discusses key milestones of diabetes technology development, focusing on the progress in the past 10 years and on the artificial pancreas—still not a cure, but arguably the most promising treatment of diabetes to date.

  10. Individuals achieve more accurate results with meters that are codeless and employ dynamic electrochemistry.

    Science.gov (United States)

    Rao, Anoop; Wiley, Meg; Iyengar, Sridhar; Nadeau, Dan; Carnevale, Julie

    2010-01-01

    Studies have shown that controlling blood glucose can reduce the onset and progression of the long-term microvascular and neuropathic complications associated with the chronic course of diabetes mellitus. Improved glycemic control can be achieved by frequent testing combined with changes in medication, exercise, and diet. Technological advancements have enabled improvements in analytical accuracy of meters, and this paper explores two such parameters to which that accuracy can be attributed. Four blood glucose monitoring systems (with or without dynamic electrochemistry algorithms, codeless or requiring coding prior to testing) were evaluated and compared with respect to their accuracy. Altogether, 108 blood glucose values were obtained for each system from 54 study participants and compared with the reference values. The analysis depicted in the International Organization for Standardization table format indicates that the devices with dynamic electrochemistry and the codeless feature had the highest proportion of acceptable results overall (System A, 101/103). Results were significant when compared at the 10% bias level with meters that were codeless and utilized static electrochemistry (p = .017) or systems that had static electrochemistry but needed coding (p = .008). Analytical performance of these blood glucose meters differed significantly depending on their technologic features. Meters that utilized dynamic electrochemistry and did not require coding were more accurate than meters that used static electrochemistry or required coding. 2010 Diabetes Technology Society.

  11. Evaluation of OneTouch Verio, a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littman, Karin; Petersen, Eva R.B.; Pussinen, Christel

    2013-01-01

    Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio® is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals...... (ADA) quality goals. Blood samples were collected and measured on the OneTouch Verio® by laboratory personnel and patients with diabetes (n = 91, randomized into groups receiving personal training or mail instructions for the OneTouch Verio® system). Results were compared to a validated routine method......, imprecision and bias were calculated. User-friendliness was evaluated with a questionnaire. Results. Quality specifications for blood glucose concentration monitoring systems according to ISO 15197 were fulfilled. The mean coefficients of variation (CV%) of repeatability was 3.4% when tested by laboratory...

  12. Association of sleep duration with blood glucose level of Gujarati Indian adolescents.

    Science.gov (United States)

    Patel, Minal C; Shaikh, Wasim A; Singh, S K

    2012-01-01

    Recently studies conducted in various parts of the world indicate short sleep duration as a novel risk factor for development of type 2 diabetes. However, ethnic differences exist in the etiopathogenesis of diseases, the current study was undertaken to study the effect of sleep duration on the blood glucose level of Gujarati Indian adolescents. A randomized, non-experimental, cross-sectional study was done on the voluntary participants n = 332 Gujarati adolescent boys and girls of age group 13-20 years studying at the schools and colleges in the Anand district. The participants were assessed for their sleep duration, body composition and blood glucose level. The sleep duration was reported by the subjects as the number of hours they slept on most of the nights in a week over the last one-year. The observations of the study were then analyzed after grouping them into: 1) Adequate sleep duration at night, ASDN (> or = 7 hrs) and 2) Inadequate sleep duration at night, ISDN (Gujarati Indian adolescents of age group 13-20 years.

  13. Obestatin and Ghrelin in Regulation of Blood Glucose%Obestatin、Ghrelin与血糖调节

    Institute of Scientific and Technical Information of China (English)

    孙杰辉

    2011-01-01

    Obestatin and ghrelin participate and antagonize each other in blood glucose regulation. Obestatin inhibits food intake, gastrointestinal evacuation and motility, and increases insulin secretion from pancreatic β-cells, whereas ghrelin enhances appetite, gastrointestinal emptying and motility, decreases fat consumption, prevents apoptosis of pancreatic (β-cells and human islets thereby controlling insulin secretion. However, the mechanisms of both obestatin and ghrelin in blood glucose regulation remain controversial.%肥胖抑制素(obestatin)和生长激素释放肽(ghrelin)能互相拮抗,参与血糖的调节.其中obestatin与GPR-39(G-protein-coupled receptor 39)结合抑制摄食和胃肠排空、促进胰岛β细胞功能,影响胰岛素的分泌;而ghrelin与生长激素促分泌受体(GHSR1a)结合,促进食欲和胃肠排空,减少脂肪的利用,抑制胰岛细胞凋亡,调节胰岛素的分泌.但两者参与血糖调节的具体机制尚存在争议.

  14. Hunger games: fluctuations in blood glucose levels influence support for social welfare.

    Science.gov (United States)

    Aarøe, Lene; Petersen, Michael Bang

    2013-12-01

    Social-welfare policies are a modern instantiation of a phenomenon that has pervaded human evolutionary history: resource sharing. Ancestrally, food was a key shared resource in situations of temporary hunger. If evolved human psychology continues to shape how individuals think about current, evolutionarily novel conditions, this invites the prediction that attitudes regarding welfare politics are influenced by short-term fluctuations in hunger. Using blood glucose levels as a physiological indicator of hunger, we tested this prediction in a study in which participants were randomly assigned to conditions in which they consumed soft drinks containing either carbohydrates or an artificial sweetener. Analyses showed that participants with experimentally induced low blood glucose levels expressed stronger support for social welfare. Using an incentivized measure of actual sharing behavior (the dictator game), we further demonstrated that this increased support for social welfare does not translate into genuinely increased sharing motivations. Rather, we suggest that it is "cheap talk" aimed at increasing the sharing efforts of other individuals.

  15. EFFECT OF REGULAR GARLIC INGESTION ON BODY WEIGHT AND BLOOD GLUCOSE: A CASE STUDY IN MICE

    Directory of Open Access Journals (Sweden)

    F.T. Djankpa, A. Osonuga*, J. Ekpale, C.E. Quaye, P. Otoo, O.A. Osonuga and S.K. Amoah

    2012-05-01

    Full Text Available Garlic a perennial erect plant is known to have sulphur-containing compounds that act on the hypothalamus increasing the sensitivity of the hypothalamus to leptin which alters the set point at which satiety is reached causing an organism to eat less. Nine mice (six of which were obese were used in this study and grouped into three. Groups A and B were made of 3 obese mice each whereas group C consisted of 3 non-obese mice. For group A and group C mice, 20 ml aqueous garlic extract was added to their feed daily whereas no garlic was added to the feed of group B mice. The study was carried out over a period of 44 days. The weight and blood glucose was measured weekly and the average for each group was computed. Results indicated that Group A mice recorded a reduction in mean body weight by 46.5% (p<0.05. Group B mice had significant increase in mean body weight by 46.2% (p<0.05. The blood glucose level dropped significantly by 18.5% (p<0.05 in group A mice. Garlic had weight loss and hypoglycemic effect in obese mice. These effects were absent in non-obese mice.

  16. Diabetes Support Groups Improve Patient’s Compliance and Control Blood Glucose Levels

    Directory of Open Access Journals (Sweden)

    Zamrotul Izzah

    2013-09-01

    Full Text Available Providing information is not enough to improve diabetic patient’s compliance and achieve goals of therapy. Patient’s good awareness as well as emotional and social supports from family and community may play an important role to improve their compliance and clinical outcomes. Therefore, diabetes support groups were developed and each support group consisted of two pharmacists, two nurses, diabetic patients and their family members. A total of 70 type 2 diabetic patient’s were enrolled and randomized into support group 1 and support group 2. Patients in the group 1 received information leaflets only, while patient in the group 2 received pharmacist counselling and information leaflets at each meeting. Patient’s awareness of diabetes and compliance with medications were assessed by a short questionnaire at baseline and final follow-up. Blood glucose and cholesterol levels were also evaluated in both groups. At the end of study, the overall patient’s awareness and compliance improved by 61.5%. The random and fasting blood glucose levels decreased over than 30% in the group 2 and around 14% in the group 1. This study reveals that collaboration between health care professionals and community in the diabetes support group might help diabetic patients to increase their knowledge and compliance with the diabetes therapy as well as glycaemic control.

  17. Reagent-free simultaneous determination of glucose and cholesterol in whole blood by FTIR-ATR

    Science.gov (United States)

    Li, Zhigang; Lv, Hong; Li, Tianhe; Si, Guangyuan; Wang, Qiaoyun; Lv, Jiangtao; Hu, Xiaofei

    2017-05-01

    Reagent-free determination of multiple analytes is an active and promising field of research in clinical analysis. In this work, the determination of glucose and cholesterol in whole blood using Fourier transform infrared (FTIR) spectroscopy equipped with an attenuated total reflectance (ATR) accessory was performed. A comprehensive sample selection rule in multi space based on SPXY was proposed, termed C-SPXY. The core idea is to make full use of different derivative spectra space to construct the calibration set which preserves the more effective information. On this basis, a partial least squares (PLS) regression fusion modeling method was also presented aiming at improving prediction accuracy of glucose and cholesterol concentration in whole blood samples. Compared with other methods based on single spectra space, the proposed fusion model based on multi spectra space C-SPXY method provides smaller RMSEP values. Experimental results demonstrate that the proposed method and model provides superior predictive power and holds a good application prospect in the field of clinical analysis.

  18. Responses of Blood Glucose, Insulin, Glucagon, and Fatty Acids to Intraruminal Infusion of Propionate in Hanwoo

    Directory of Open Access Journals (Sweden)

    Y. K. Oh

    2015-02-01

    Full Text Available This study was carried out to investigate the effects of intraruminal infusion of propionate on ruminal fermentation characteristics and blood hormones and metabolites in Hanwoo (Korean cattle steers. Four Hanwoo steers (average body wt. 270 kg, 13 month of age equipped with rumen cannula were infused into rumens with 0.0 M (Water, C, 0.5 M (37 g/L, T1, 1.0 M (74 g/L, T2 and 1.5 M (111 g/L, T3 of propionate for 1 hour per day and allotted by 4×4 Latin square design. On the 5th day of infusion, samples of rumen and blood were collected at 0, 60, 120, 180, and 300 min after intraruminal infusion of propionate. The concentrations of serum glucose and plasma glucagon were not affected (p>0.05 by intraruminal infusion of propionate. The serum insulin concentration at 60 min after infusion was significantly (p<0.05 higher in T3 than in C, while the concentration of non-esterified fatty acid (NEFA at 60 and 180 min after infusion was significantly (p<0.05 lower in the propionate treatments than in C. Hence, intraruminal infusion of propionate stimulates the secretion of insulin, and decreases serum NEFA concentration rather than the change of serum glucose concentration.

  19. Effect of curcumin supplementation on blood glucose, plasma insulin, and glucose homeostasis related enzyme activities in diabetic db/db mice.

    Science.gov (United States)

    Seo, Kwon-Il; Choi, Myung-Sook; Jung, Un Ju; Kim, Hye-Jin; Yeo, Jiyoung; Jeon, Seon-Min; Lee, Mi-Kyung

    2008-09-01

    We investigated the effect of curcumin on insulin resistance and glucose homeostasis in male C57BL/KsJ-db/db mice and their age-matched lean non-diabetic db/+ mice. Both db/+ and db/db mice were fed with or without curcumin (0.02%, wt/wt) for 6 wks. Curcumin significantly lowered blood glucose and HbA 1c levels, and it suppressed body weight loss in db/db mice. Curcumin improved homeostasis model assessment of insulin resistance and glucose tolerance, and elevated the plasma insulin level in db/db mice. Hepatic glucokinase activity was significantly higher in the curcumin-supplemented db/db group than in the db/db group, whereas glucose-6-phosphatase and phosphoenolpyruvate carboxykinase activities were significantly lower. In db/db mice, curcumin significantly lowered the hepatic activities of fatty acid synthase, beta-oxidation, 3-hydroxy-3-methylglutaryl coenzyme reductase, and acyl-CoA: cholesterol acyltransferase. Curcumin significantly lowered plasma free fatty acid, cholesterol, and triglyceride concentrations and increased the hepatic glycogen and skeletal muscle lipoprotein lipase in db/db mice. Curcumin normalized erythrocyte and hepatic antioxidant enzyme activities (superoxide dismutase, catalase, gluthathione peroxidase) in db/db mice that resulted in a significant reduction in lipid peroxidation. However, curcumin showed no effect on the blood glucose, plasma insulin, and glucose regulating enzyme activities in db/+ mice. These results suggest that curcumin seemed to be a potential glucose-lowering agent and antioxidant in type 2 diabetic db/db mice, but had no affect in non-diabetic db/+ mice.

  20. USING CAPILLARY WHOLE BLOOD GLUCOSE TEST IN SCREENING FOR GESTATIONAL DIABETES MELLITUS

    Institute of Scientific and Technical Information of China (English)

    WU Qing-kai; LUO Lai-min; GU Jing-hong; LI Ping; HUANG Ya-juan; FENG Jie; ZHANG Rui

    2007-01-01

    Objective To discuss whether the capillary whole blood glucose (CBG) test can be used in glucose screening test (GST) for gestational diabetes mellitus (GDM) compared to the venous plasma glucose (VPG) method, and to determine the cutoff value of CBG. Methods This was a self-control test. The 50-g oral GST was conducted among 1 557 pregnant women between 24-28 weeks. Every woman was measured CBG and VPG at the same time and same arm. Three hundred and forty women underwent 100-g 3-h oral glucose tolerance test (OGTT). Receiver operation curve (ROC) was used to determine the potential cutoff level of CBG and VPG. Diagnose criteria of GDM was based on NDDG criteria. OGTT diagnosed GDM and VPG ≥ 7. 8 mmol/L were used as golden standard for ROC. Results There was good relationship between CBG and VPG ( P < 0.01 ). Correlation coefficient was 0. 86. The value of CBG was lower than VPG. The statistical and high-sensitivity cutoff values were 7. 4 mmol/L in CBG and 7. 8 mmol/L in VPG when GDM was used as golden standard. Cutoff value of CBG was 7. 0 mmol/L when VPG≥ 7. 8 mmol/L was used as golden standard. The pregnant outcomes of positive cases of three thresholds had no significant differences. But it was better in case of the pregnant woman when the CBG value was more than 7. 4 mmol/L. Conclusion CBG can be used in GST, the threshold of CBG was suggested as 7. 4 mmol/L. CBG test was more convenience and effective than VPG test.

  1. Effects of nicarbazin on the blood glucose and liver glycogen statuses of male broilers.

    Science.gov (United States)

    Peebles, E D; Bafundo, K W; Womack, S K; Zhai, W; Pulikanti, R; Bennett, L W

    2012-09-01

    Nicarbazin (NCZ), an effective anticoccidial widely used by the global broiler industry, is known to produce some side effects in broilers. Recent field observations have suggested that NCZ could be associated with spiking mortality syndrome, a disease of uncertain etiology that is most commonly characterized by hypoglycemia. In turn, 2 trials were conducted to investigate the effects of NCZ on the blood glucose levels and liver glycogen content of Ross × Ross 708 male broilers. In 6 of 12 pens beginning at 1 d of age, NCZ was added to basal broiler diets at a rate of 125 mg/kg, and the other 6 pens were control pens in which birds received salinomycin instead of NCZ, at a rate of 66 mg/kg. Feed and water were provided ad libitum, feed was closely monitored in all pens to avoid shortages, no coccidial challenge was imposed, and room temperature never exceeded 29.4°C. At the end of the second trial, a photoperiod increase from 8L:16D to 24L:0D was imposed in an effort to induce stress due to feed engorgement. In response to NCZ in trial 1, 0 to 28 d feed conversion and relative liver weights on d 21 and 28 were higher, whereas 0 to 28 d cumulative BW gain was lower. In response to NCZ in trial 2, 0 to 13 d feed conversion was higher, whereas 0 to 13 d cumulative BW gain was lower. The added NCZ increased blood glucose on d 13 in trial 2, but did not affect at any time the liver constituents analyzed in both trials. In conclusion, the uninterrupted feeding of NCZ at 125 mg/kg in the starter and grower diets of male Ross × Ross 708 broilers increased feed conversion and reduced BW gain, but despite an increase in relative liver weight on d 21 and 28 posthatch, liver glucose and glycogen concentrations were not affected.

  2. A PI-fuzzy logic controller for the regulation of blood glucose level in diabetic patients.

    Science.gov (United States)

    Ibbini, M

    2006-01-01

    This manuscript investigates different fuzzy logic controllers for the regulation of blood glucose level in diabetic patients. While fuzzy logic control is still intuitive and at a very early stage, it has already been implemented in many industrial plants and reported results are very promising. A fuzzy logic control (FLC) scheme was recently proposed for maintaining blood glucose level in diabetics within acceptable limits, and was shown to be more effective with better transient characteristics than conventional techniques. In fact, FLC is based on human expertise and on desired output characteristics, and hence does not require precise mathematical models. This observation makes fuzzy rule-based technique very suitable for biomedical systems where models are, in general, either very complicated or over-simplistic. Another attractive feature of fuzzy techniques is their insensitivity to system parameter variations, as numerical values of physiological parameters are often not precise and usually vary from patient to another. PI and PID controllers are very popular and are efficiently used in many industrial plants. Fuzzy PI and PID controllers behave in a similar fashion to those classical controllers with the obvious advantage that the controller parameters are time dependant on the range of the control variables and consequently, result in a better performance. In this manuscript, a fuzzy PI controller is designed using a simplified design scheme and then subjected to simulations of the two common diabetes disturbances--sudden glucose meal and system parameter variations. The performance of the proposed fuzzy PI controller is compared to that of the conventional PID and optimal techniques and is shown to be superior. Moreover, the proposed fuzzy PI controller is shown to be more effective than the previously proposed FLC, especially with respect to the overshoot and settling time.

  3. Dietary intake, food pattern, and abnormal blood glucose status of middle-aged adults: a cross-sectional community-based study in Myanmar

    Directory of Open Access Journals (Sweden)

    Hlaing Hlaing Hlaing

    2016-05-01

    Full Text Available Background: Lifestyle changes, particularly dietary intake, had resulted in increasing trends of type-2 diabetes mellitus worldwide. However, dietary intake is diverse across country contexts. This study aimed to compare the dietary intake, food patterns, and blood glucose among middle-aged adults living in urban and suburban areas in Mandalay city, Myanmar, and explore their relationships. Methods: A cross-sectional community-based study was conducted during June–November 2014. Adults aged 35–64 were randomly selected and requested to record all food they ate in a 4-day diary. Fasting and 2-hour postprandial blood glucose values were measured over two consecutive days. Dietary intakes were calculated in terms of energy, macronutrients, glycemic index, and glycemic load, and food patterns were identified by factor analysis. The relationships between food pattern, dietary intake, and blood glucose were assessed. Results: Of 440 participants, dietary intake between urban and suburban residents was significantly different. Six food patterns were identified. There was no difference in fasting and 2-hour postprandial blood glucose between urban and suburban residents, but a strong correlation between fasting blood glucose and 2-hour postprandial blood glucose was found (correlation coefficient=0.8. Identification of abnormal blood glucose status using original fasting and converted 2-hour postprandial values showed substantial agreement (prevalence-adjusted bias-adjusted Kappa= 0.8. Relationships between food patterns and blood glucose or abnormal blood glucose status were not found. Conclusion: Food patterns were associated with dietary intake, not with abnormal blood glucose status. Two-hour postprandial blood glucose was highly correlated with fasting blood glucose and may be used for identifying abnormal blood glucose status.

  4. Dietary intake, food pattern, and abnormal blood glucose status of middle-aged adults: a cross-sectional community-based study in Myanmar.

    Science.gov (United States)

    Hlaing, Hlaing Hlaing; Liabsuetrakul, Tippawan

    2016-01-01

    Lifestyle changes, particularly dietary intake, had resulted in increasing trends of type-2 diabetes mellitus worldwide. However, dietary intake is diverse across country contexts. This study aimed to compare the dietary intake, food patterns, and blood glucose among middle-aged adults living in urban and suburban areas in Mandalay city, Myanmar, and explore their relationships. A cross-sectional community-based study was conducted during June-November 2014. Adults aged 35-64 were randomly selected and requested to record all food they ate in a 4-day diary. Fasting and 2-hour postprandial blood glucose values were measured over two consecutive days. Dietary intakes were calculated in terms of energy, macronutrients, glycemic index, and glycemic load, and food patterns were identified by factor analysis. The relationships between food pattern, dietary intake, and blood glucose were assessed. Of 440 participants, dietary intake between urban and suburban residents was significantly different. Six food patterns were identified. There was no difference in fasting and 2-hour postprandial blood glucose between urban and suburban residents, but a strong correlation between fasting blood glucose and 2-hour postprandial blood glucose was found (correlation coefficient=0.8). Identification of abnormal blood glucose status using original fasting and converted 2-hour postprandial values showed substantial agreement (prevalence-adjusted bias-adjusted Kappa=0.8). Relationships between food patterns and blood glucose or abnormal blood glucose status were not found. Food patterns were associated with dietary intake, not with abnormal blood glucose status. Two-hour postprandial blood glucose was highly correlated with fasting blood glucose and may be used for identifying abnormal blood glucose status.

  5. Effects of Cinnamomum zeylanicum (Ceylon cinnamon on blood glucose and lipids in a diabetic and healthy rat model

    Directory of Open Access Journals (Sweden)

    Priyanga Ranasinghe

    2012-01-01

    Full Text Available Objectives: To evaluate short- and long-term effects of Cinnamomum zeylanicum on food consumption, body weight, glycemic control, and lipids in healthy and diabetes-induced rats. Materials and Methods: The study was conducted in two phases (Phase I and Phase II, using Sprague-Dawley rats in four groups. Phase I evaluated acute effects on fasting blood glucose (FBG (Groups 1 and 2 and on post-oral glucose (Groups 3 and 4 blood glucose. Groups 1 and 3 received distilled-water and Groups 2 and 4 received cinnamon-extracts. Phase II evaluated effects on food consumption, body weight, blood glucose, and lipids over 1 month. Group A (n = 8, distilled-water and Group B (n = 8, cinnamon-extracts were healthy rats, while Group C (n = 5, distilled-water and Group D (n = 5, cinnamon-extracts were diabetes-induced rats. Serum lipid profile and HbA1c were measured on D-0 and D-30. FBG, 2-h post-prandial blood glucose, body weight, and food consumption were measured on every fifth day. Results: Phase I: There was no significant difference in serial blood glucose values in cinnamon-treated group from time 0 (P > 0.05. Following oral glucose, the cinnamon group demonstrated a faster decline in blood glucose compared to controls (P < 0.05. Phase II: Between D0 and D30, the difference in food consumption was shown only in diabetes-induced rats (P < 0.001. Similarly, the significant difference following cinnamon-extracts in FBG and 2-h post-prandial blood glucose from D0 to D30 was shown only in diabetes-induced rats. In cinnamon-extracts administered groups, total and LDL cholesterol levels were lower on D30 in both healthy and diabetes-induced animals (P < 0.001. Conclusions: C. zeylanicum lowered blood glucose, reduced food intake, and improved lipid parameters in diabetes-induced rats.

  6. Glucose-6-Phosphate Dehydrogenase Deficiency among Male Blood Donors in Sana’a City, Yemen

    Science.gov (United States)

    Al-Nood, Hafiz A.; Bazara, Fakiha A.; Al-Absi, Rashad; Habori, Molham AL

    2012-01-01

    Objectives To determine the prevalence of Glucose-6-phosphate dehydrogenase (G-6-PD) deficiency among Yemeni people from different regions of the country living in the capital city, Sana’a, giving an indication of its overall prevalence in Yemen. Methods A cross-sectional study was conducted among Yemeni male blood donors attending the Department of Blood Bank at the National Centre of the Public Health Laboratories in the capital city, Sana’a, Yemen. Fluorescent spot method was used for screening, spectrophotometeric estimation of G-6-PD activity and separation by electrophoresis was done to determine the G-6-PD phenotype. Results Of the total 508 male blood donors recruited into the study, 36 were G-6-PD deficient, giving a likely G-6-PD deficiency prevalence of 7.1%. None of these deficient donors had history of anemia or jaundice. Thirty-five of these deficient cases (97.2%) showed severe G-6-PD deficiency class II (<10% of normal activity), and their phenotyping presumptively revealed a G-6-PD-Mediterranean variant. Conclusion The results showed a significant presence of G-6-PD deficiency with predominance of a severe G-6-PD deficiency type in these blood donors in Sana’a City, which could represent an important health problem through occurrence of hemolytic anemia under oxidative stress. A larger sample size is needed to determine the overall prevalence of G-6-PD deficiency, and should be extended to include DNA analysis to identify its variants in Yemen. PMID:22359725

  7. Dietary thylakoids suppress blood glucose and modulate appetite-regulating hormones in pigs exposed to oral glucose tolerance test

    DEFF Research Database (Denmark)

    Montelius, Caroline; Szwiec, Katarzyna; Kardas, Marek

    2014-01-01

    BACKGROUND & AIMS: Dietary chloroplast thylakoids have previously been found to reduce food intake and body weight in animal models, and to change metabolic profiles in humans in mixed-food meal studies. The aim of this study was to investigate the modulatory effects of thylakoids on glucose......, and decreased late postprandial secretion of ghrelin. CONCLUSION: Dietary thylakoids may be a novel agent in reducing the glycaemic responses to high carbohydrate and high glycaemic index foods. Thylakoids may in the future be promising for treatment and prevention of diabetes, overweight and obesity....... metabolism and appetite-regulating hormones during an oral glucose tolerance test in pigs fed a high fat diet. METHODS: Six pigs were fed a high fat diet (36 energy% fat) for one month before oral glucose tolerance test (1 g/kg d-glucose) was performed. The experiment was designed as a cross-over study...

  8. Clinical review: the misreporting of logbook, download, and verbal self-measured blood glucose in adults and children with type I diabetes.

    Science.gov (United States)

    Blackwell, Miranda; Wheeler, Benjamin J

    2017-01-01

    Despite advances in technology, the frequent self-measurement of blood glucose (SMBG) remains fundamental to the management of 1 diabetes mellitus (T1DM). Once measured, SMBG results are routinely reported back to health professionals and other interested parties, either verbally, via a logbook, or electronically downloaded from a pump or meter. The misreporting of SMBG using various techniques represents a classic non-adherence behavior and carries with it both acute and chronic dangers. In addition, while this behavior appears very prevalent, many aspects remain largely unstudied. With this in mind, we aimed to summarize literature addressing the misreporting of SMBG in T1DM via a detailed literature search. This produced both recent and past literature. While most of these studies examined the prevalence of deliberate misreporting in a verbal or logbook context, others focused on the motivations behind this behavior, and alternative forms of misreporting, including deliberate manipulation of meters to produce inaccurate results and true technological errors. This timely review covers all aspects of misreporting and highlights multiple patient techniques, which are clearly adapting to advances in technology. We believe that further understanding and attention to this aspect of adherence may lead not only to improvements in glycemic control and safety, but also to the psychological well-being of those affected by type 1 diabetes.

  9. Long-term effects of daily postprandial physical activity on blood glucose: a randomized controlled trial.

    Science.gov (United States)

    Nygaard, Håvard; Grindaker, Eirik; Rønnestad, Bent Ronny; Holmboe-Ottesen, Gerd; Høstmark, Arne Torbjørn

    2017-04-01

    Previous studies have shown that a bout of moderate or light postprandial physical activity effectively blunts the postprandial increase in blood glucose. The objective of this study was to test whether regular light postprandial physical activity can improve glycemia in persons with hyperglycemia or with a high risk of hyperglycemia. We randomized 56 participants to an intervention or a control group. They were diagnosed as hyperglycemic, not using antidiabetics, or were categorized as high-risk individuals for type 2 diabetes. The intervention group was instructed to undertake a minimum 30 min of daily light physical activity, starting a maximum of 30 min after a meal in addition to their usual physical activity for 12 weeks. The control group maintained their usual lifestyle. Blood samples were taken pre- and post-test. Forty participants completed the study and are included in the results. The self-reported increase in daily physical activity from before to within the study period was higher in the intervention group compared with control (41 ± 25 vs. 2 ± 16 min, p < 0.001). Activity diaries and accelerometer recordings supported this observation. The activity in the intervention group started earlier after the last meal compared with control (30 ± 13 vs. 100 ± 57 min, p = 0.001). There were no within- or between-group differences in any glycemic variable from pre- to post-test. In conclusion, the present study does not seem to support the notion that regular light postprandial physical activity improves blood glucose in the long term in persons with hyperglycemia or with high risk of hyperglycemia.

  10. Improving Detection of Prediabetes in Children and Adults: Using Combinations of Blood Glucose Tests

    Directory of Open Access Journals (Sweden)

    Ike Solomon Okosun

    2015-11-01

    Full Text Available Aim: To determine combinations of blood glucose tests: oral glucose tolerance (OGT, fasting plasma glucose (FBG and hemoglobin A1C (HbA1C that are associated with highest diagnostic rates of prediabetes in non-diabetic American children and adults.Methods: The 2007-2008 U.S. National Health and Nutrition Examination Surveys data were used for this study. Overall and specific prevalence of prediabetes (defined using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were determined across age, race/ethnicity, sex and BMI categories.Results: FPG+HbA1C test was associated with significantly higher diagnostic rates of prediabetes across age, race/ethnicity and BMI. Estimates of overall prevalence of prediabetes using OGT+FPG, OGT+HbA1C, HbA1C+FPG and OGT+FPG+HbA1C tests were 20.3%, 24.2%, 33% and 34.3%, respectively. Compared to OGT+FPG, the use of HbA1C+FPG test in screening was associated with 44.8%, 135%, 38.6% and 35.9% increased prevalence of prediabetes in non-Hispanic White, non-Hispanic Black, Mexican-American and other racial/ethnic men, respectively. The corresponding values in women were 67.8%, 140%, 37.2% and 42.6%, respectively. Combined use of all blood glucose tests did not improve the overall and gender-specific prediabetes prevalence beyond what was observed using HbA1C+FPG test.Conclusions: HbA1C criteria were associated with higher diagnosis rates of prediabetes than FPG and OGT tests in non-diabetic American children and adults. Using a combination of HbA1C and FPG test in screening for prediabetes reduces intrinsic systematic bias in using just HbA1C testing and offers the benefits of each test. A well-defined HbA1C that takes into consideration race/ethnicity, gender, age and body mass index may improve detection of prediabetes in population and clinical settings.

  11. Critical Care Glucose Point-of-Care Testing.

    Science.gov (United States)

    Narla, S N; Jones, M; Hermayer, K L; Zhu, Y

    Maintaining blood glucose concentration within an acceptable range is a goal for patients with diabetes mellitus. Point-of-care glucose meters initially designed for home self-monitoring in patients with diabetes have been widely used in the hospital settings because of ease of use and quick reporting of blood glucose information. They are not only utilized for the general inpatient population but also for critically ill patients. Many factors affect the accuracy of point-of-care glucose testing, particularly in critical care settings. Inaccurate blood glucose information can result in unsafe insulin delivery which causes poor glucose control and can be fatal. Healthcare professionals should be aware of the limitations of point-of-care glucose testing. This chapter will first introduce glucose regulation in diabetes mellitus, hyperglycemia/hypoglycemia in the intensive care unit, importance of glucose control in critical care patients, and pathophysiological variables of critically ill patients that affect the accuracy of point-of-care glucose testing. Then, we will discuss currently available point-of-care glucose meters and preanalytical, analytical, and postanalytical sources of variation and error in point-of-care glucose testing.

  12. Effect of commercial rye whole-meal bread on postprandial blood glucose and gastric emptying in healthy subjects

    OpenAIRE

    Darwich Gassan; Björgell Ola; Lindstedt Sandra; Jönsson Jenny; Hlebowicz Joanna; Almér Lars-Olof

    2009-01-01

    Abstract Background The intake of dietary fibre has been shown to reduce the risk of developing diabetes mellitus. The aim of this study was to compare the effects of commercial rye whole-meal bread containing whole kernels and white wheat bread on the rate of gastric emptying and postprandial glucose response in healthy subjects. Methods Ten healthy subjects took part in a blinded crossover trial. Blood glucose level and gastric emptying rate (GER) were determined after the ingestion of 150 ...

  13. Continuous Glucose Monitoring Systems: A Review

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2013-10-01

    Full Text Available There have been continuous advances in the field of glucose monitoring during the last four decades, which have led to the development of highly evolved blood glucose meters, non-invasive glucose monitoring (NGM devices and continuous glucose monitoring systems (CGMS. Glucose monitoring is an integral part of diabetes management, and the maintenance of physiological blood glucose concentration is the only way for a diabetic to avoid life-threatening diabetic complications. CGMS have led to tremendous improvements in diabetic management, as shown by the significant lowering of glycated hemoglobin (HbA1c in adults with type I diabetes. Most of the CGMS have been minimally-invasive, although the more recent ones are based on NGM techniques. This manuscript reviews the advances in CGMS for diabetes management along with the future prospects and the challenges involved.

  14. Effect of Fasting Blood Glucose Level on Heart Rate Variability of Healthy Young Adults.

    Directory of Open Access Journals (Sweden)

    Mohamed Faisal Lutfi

    Full Text Available Previous studies reported increased risk of cardiac events in subjects with fasting blood glucose (FBG levels lower than the diagnostic threshold of diabetes mellitus. However, whether increased cardiac events in those with upper normal FBG is secondary to the shift of their cardiac sympathovagal balance towards sympathetic predominance is unknown.To assess the association between FBG levels and cardiac autonomic modulation (CAM in euglycaemic healthy subjects based on heart rate variability (HRV derived indices.The study enrolled 42 healthy young adults. Following sociodemographic and clinical assessment, blood samples were collected to measure FBG levels. Five minutes ECG recordings were performed to all participants to obtain frequency domain HRV measurements, namely the natural logarithm (Ln of total power (LnTP, very low frequency (LnVLF, low frequency (LnLF and high frequency (LnHF, low frequency/ high frequency ratio (LnLF/HF, normalized low frequency (LF Norm and high frequency (HF Norm.FBG levels correlated positively with LnHF (r = 0.33, P = 0.031 and HF Norm (r = 0.35, P = 0.025 and negatively with LF Norm (r = -0.35, P = 0.025 and LnLF/HF (r = -0.33, P = 0.035. LnHF and HF Norm were significantly decreased in subjects with the lower (4.00 (1.34 ms2/Hz and 33.12 (11.94 n.u compared to those with the upper FBG quartile (5.64 (1.63 ms2/Hz and 49.43 (17.73 n.u, P = 0.013 and 0.032 respectively. LF Norm and LnLF/HF were significantly increased in subjects with the lower (66.88 (11.94 n.u and 0.73 (0.53 compared to those with the higher FBG quartile (50.58 (17.83 n.u and 0.03 (0.79, P = 0.032 and 0.038 respectively.The present study is the first to demonstrate that rise of blood glucose concentration, within physiological range, is associated with higher parasympathetic, but lower sympathetic CAM. Further researches are needed to set out the glycemic threshold beyond which further increase in glucose level readjusts sympathovagal balance

  15. Gcg-XTEN: an improved glucagon capable of preventing hypoglycemia without increasing baseline blood glucose.

    Directory of Open Access Journals (Sweden)

    Nathan C Geething

    Full Text Available OBJECTIVE: While the majority of current diabetes treatments focus on reducing blood glucose levels, hypoglycemia represents a significant risk associated with insulin treatment. Glucagon plays a major regulatory role in controlling hypoglycemia in vivo, but its short half-life and hyperglycemic effects prevent its therapeutic use for non-acute applications. The goal of this study was to identify a modified form of glucagon suitable for prophylactic treatment of hypoglycemia without increasing baseline blood glucose levels. METHODOLOGY/PRINCIPAL FINDINGS: Through application of the XTEN technology, we report the construction of a glucagon fusion protein with an extended exposure profile (Gcg-XTEN. The in vivo half-life of the construct was tuned to support nightly dosing through design and testing in cynomolgus monkeys. Efficacy of the construct was assessed in beagle dogs using an insulin challenge to induce hypoglycemia. Dose ranging of Gcg-XTEN in fasted beagle dogs demonstrated that the compound was biologically active with a pharmacodynamic profile consistent with the designed half-life. Prophylactic administration of 0.6 nmol/kg Gcg-XTEN to dogs conferred resistance to a hypoglycemic challenge at 6 hours post-dose without affecting baseline blood glucose levels. Consistent with the designed pharmacokinetic profile, hypoglycemia resistance was not observed at 12 hours post-dose. Importantly, the solubility and stability of the glucagon peptide were also significantly improved by fusion to XTEN. CONCLUSIONS/SIGNIFICANCE: The data show that Gcg-XTEN is effective in preventing hypoglycemia without the associated hyperglycemia expected for unmodified glucagon. While the plasma clearance of this Gcg-XTEN has been optimized for overnight dosing, specifically for the treatment of nocturnal hypoglycemia, constructs with significantly longer exposure profiles are feasible. Such constructs may have multiple applications such as allowing for more

  16. Effect of post-exercise caffeine and green coffee bean extract consumption on blood glucose and insulin concentrations.

    Science.gov (United States)

    Beam, Jason R; Gibson, Ann L; Kerksick, Chad M; Conn, Carole A; White, Ailish C; Mermier, Christine M

    2015-02-01

    The aim of this study was to investigate the effects of ingesting caffeine and green coffee bean extract on blood glucose and insulin concentrations during a post-exercise oral glucose tolerance test. Ten male cyclists (age: 26 ± 5 y; height: 179.9 ± 5.4 cm; weight: 77.6 ± 13.3 kg; body mass index: 24 ± 4.3 kg/m(2); VO2 peak: 55.9 ± 8.4 mL·kg·min(-1)) participated in this study. In a randomized order, each participant completed three 30-min bouts of cycling at 60% of peak power output. Immediately after exercise, each participant consumed 75 g of dextrose with either 5 mg/kg body weight of caffeine, 10 mg/kg of green coffee bean extract (5 mg/kg chlorogenic acid), or placebo. Venous blood samples were collected immediately before and after exercise during completion of the oral glucose tolerance test. No significant time × treatment effects for blood glucose and insulin were found. Two-h glucose and insulin area under the curve values, respectively, for the caffeine (658 ± 74 mmol/L and 30,005 ± 13,304 pmol/L), green coffee bean extract (637 ± 100 mmol/L and 31,965 ± 23,586 pmol/L), and placebo (661 ± 77 mmol/L and 27,020 ± 12,339 pmol/L) trials were not significantly different (P > 0.05). Caffeine and green coffee bean extract did not significantly alter postexercise blood glucose and insulin concentrations when compared with a placebo. More human research is needed to determine the impact of these combined nutritional treatments and exercise on changes in blood glucose and insulin. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Impaired fasting blood glucose is associated to cognitive impairment and cerebral atrophy in middle-aged non-human primates

    Science.gov (United States)

    Djelti, Fathia; Dhenain, Marc; Terrien, Jérémy; Picq, Jean-Luc; Hardy, Isabelle; Champeval, Delphine; Perret, Martine; Schenker, Esther; Epelbaum, Jacques; Aujard, Fabienne

    2017-01-01

    Age-associated cognitive impairment is a major health and social issue because of increasing aged population. Cognitive decline is not homogeneous in humans and the determinants leading to differences between subjects are not fully understood. In middle-aged healthy humans, fasting blood glucose levels in the upper normal range are associated with memory impairment and cerebral atrophy. Due to a close evolutional similarity to Man, non-human primates may be useful to investigate the relationships between glucose homeostasis, cognitive deficits and structural brain alterations. In the grey mouse lemur, Microcebus murinus, spatial memory deficits have been associated with age and cerebral atrophy but the origin of these alterations have not been clearly identified. Herein, we showed that, on 28 female grey mouse lemurs (age range 2.4-6.1 years-old), age correlated with impaired fasting blood glucose (rs=0.37) but not with impaired glucose tolerance or insulin resistance. In middle-aged animals (4.1-6.1 years-old), fasting blood glucose was inversely and closely linked with spatial memory performance (rs=0.56) and hippocampus (rs=−0.62) or septum (rs=−0.55) volumes. These findings corroborate observations in humans and further support the grey mouse lemur as a natural model to unravel mechanisms which link impaired glucose homeostasis, brain atrophy and cognitive processes. PMID:28039490

  18. Evaluation of OneTouch Verio(®), a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littmann, Karin; Petersen, Eva; Pussinen, Christel;

    2013-01-01

    Introduction. Self-monitoring of blood glucose (SMBG) is important in diabetes management. Reliable and user-friendly instruments are essential. OneTouch Verio(®) is a new blood glucose concentration-measuring system designed to be used by patients with diabetes and healthcare professionals...... routine method, imprecision and bias were calculated. User-friendliness was evaluated with a questionnaire. Results. Quality specifications for blood glucose concentration monitoring systems according to ISO 15197 were fulfilled. The mean coefficients of variation (CV%) of repeatability was 3.4% when....... The objective of the present study was to evaluate the analytical performance of the OneTouch Verio(®). Method. The OneTouch Verio(®) was evaluated by the Scandinavian evaluation of laboratory equipment for primary healthcare (SKUP) according to a protocol based on ISO 15197 and the American Diabetes...

  19. Effects of Petroselinum crispum extract on pancreatic B cells and blood glucose of streptozotocin-induced diabetic rats.

    Science.gov (United States)

    Yanardağ, Refiye; Bolkent, Sehnaz; Tabakoğlu-Oğuz, Ayse; Ozsoy-Saçan, Ozlem

    2003-08-01

    This study investigated both morphologically and biochemically whether parsley (Petroselinum crispum), which is used as a folk remedy to decrease blood glucose, has any antidiabetic effect on pancreatic B cells of rats. Parsley extract was given to male diabetic rats. In the diabetic group given parsley extract, it was detected that the number of secretory granules and cells in islets and other morphologic changes were not different from the control diabetic group, while the blood glucose levels in the diabetic group given the plant extract were reduced in comparison to the diabetic group. In addition, a decrease was observed in the weight of the control diabetic group and the diabetic group given the plant extract. It is suggested that the plant therapy can provide blood glucose homeostasis and cannot regenerate B cells of the endocrine pancreas.

  20. Effect of extract of Abrus precatorius on blood glucose con-centration of alloxan induced diabetic Albino Wistar Rats

    Institute of Scientific and Technical Information of China (English)

    Georgewill OA; Georgewill UO

    2009-01-01

    Objective:To evaluate the effect of extract of Abrus precatorius on blood glucose of alloxan induced albino wist-ar rats.Methods:Experimental animals received daily oral administration of extract of Abrus precatorius for 14 days.The effect of 200 mg/kg dose was studied during the treatment period.Results:There was a significant reduction in blood glucose concentration (P <0.05)with the mean blood glucose of the different groups as 5.0 ±0.3 for normal control,7.0 ±0.4 for diabetic control group and 4.0 ±0.2 for diabetic treated group. Conclusion:The findings of this study suggest that extract of Abrus precatorius has hypoglycemic effect.

  1. Strength of family history in predicting levels of blood pressure, plasma glucose and cholesterol.

    Science.gov (United States)

    Wandeler, G; Paccaud, F; Vollenweider, P; Waeber, G; Mooser, V; Bochud, M

    2010-01-01

    Limited information is available on the quantitative relationship between family history and the corresponding underlying traits. We analyzed these associations for blood pressure, fasting blood glucose, and cholesterol levels. Data were obtained from 6,102 Caucasian participants (2,903 men and 3,199 women) aged 35-75 years using a population-based cross-sectional survey in Switzerland. Cardiovascular disease risk factors were measured, and the corresponding family history was self-reported using a structured questionnaire. The prevalence of a positive family history (in first-degree relatives) was 39.6% for hypertension, 22.3% for diabetes, and 29.0% for hypercholesterolemia. Family history was not known for at least one family member in 41.8% of participants for hypertension, 14.4% for diabetes, and 50.2% for hypercholesterolemia. A positive family history was strongly associated with higher levels of the corresponding trait, but not with the other traits. Participants who reported not to know their family history of hypertension had a higher systolic blood pressure than participants with a negative history. Sibling histories had higher positive predictive values than parental histories. The ability to discriminate, calibrate, and reclassify was best for the family history of hypertension. Family history of hypertension, diabetes, and hypercholesterolemia was strongly associated with the corresponding dichotomized and continuous phenotypes. Copyright 2009 S. Karger AG, Basel.

  2. Markers of glycemic control in the mouse: comparisons of 6-h- and overnight-fasted blood glucoses to Hb A1c.

    Science.gov (United States)

    Han, Byoung Geun; Hao, Chuan-Ming; Tchekneva, Elena E; Wang, Ying-Ying; Lee, Chieh Allen; Ebrahim, Benyamin; Harris, Raymond C; Kern, Timothy S; Wasserman, David H; Breyer, Matthew D; Qi, Zhonghua

    2008-10-01

    The present studies examined the relationship between fasting blood glucose and Hb A(1c) in C57BL/6J, DBA/2J, and KK/HlJ mice with and without diabetes mellitus. Daily averaged blood glucose levels based on continuous glucose monitoring and effects of 6-h vs. overnight fasting on blood glucose were determined. Daily averaged blood glucose levels were highly correlated with Hb A(1c), as determined with a hand-held automated device using an immunodetection method. R(2) values were 0.90, 0.95, and 0.99 in KK/HIJ, C57BL/6J, and DBA/2J, respectively. Six-hour fasting blood glucose correlated more closely with the level of daily averaged blood glucose and with Hb A(1c) than did blood glucose following an overnight fast. To validate the immunoassay-determined Hb A(1c), we also measured total glycosylated hemoglobin using boronate HPLC. Hb A(1c) values correlated well with total glycosylated hemoglobin in all three strains but were relatively lower than total glycosylated hemoglobin in diabetic DBA/2J mice. These results show that 6-h fasting glucose provides a superior index of glycemic control and correlates more closely with Hb A(1c) than overnight-fasted blood glucose in these strains of mice.

  3. Association between self-monitoring of blood glucose and diet among minority patients with diabetes*

    Science.gov (United States)

    McANDREW, Lisa M.; HOROWITZ, Carol R.; LANCASTER, Kristie J.; QUIGLEY, Karen S.; POGACH, Leonard M.; MORA, Pablo A.; LEVENTHAL, Howard

    2015-01-01

    Background Self-monitoring of blood glucose (SMBG) is used to regulate glucose control. It is unknown whether SMBG can motivate adherence to dietary recommendations. We predicted that participants who used more SMBG would also report lower fat and greater fruit and vegetable consumption. Methods The present study was a cross-sectional study of 401 primarily minority individuals living with diabetes in East Harlem, New York. Fat intake and fruit and vegetable consumption were measured with the Block Fruit/Vegetable/Fiber and Fat Screeners. Results Greater frequency of SMBG was associated with lower fat intake (rs = −0.15; P < 0.01), but not fruit and vegetable consumption. The effects of SMBG were not moderated by insulin use; thus, the relationship was significant for those individuals both on and not on insulin. A significant interaction was found between frequency of SMBG and changing one’s diet in response to SMBG on total fat intake. The data suggest that participants who use SMBG to guide their diet do not have to monitor multiple times a day to benefit. Conclusion The present study found that the frequency of SMBG was associated with lower fat intake. Patients are often taught to use SMBG to guide their self-management. This is one of the first studies to examine whether SMBG is associated with better dietary intake. PMID:21599868

  4. Peripheral and central venous blood glucose concentrations in dogs and cats with acute arterial thromboembolism.

    Science.gov (United States)

    Klainbart, S; Kelmer, E; Vidmayer, B; Bdolah-Abram, T; Segev, G; Aroch, I

    2014-01-01

    Acute limb paralysis because of arterial thromboembolism (ATE) occurs in cats and less commonly in dogs. ATE is diagnosed based on physical examination findings and, occasionally, advanced imaging. Peripheral, affected limb venous glucose concentration is decreased in ATE, whereas its systemic concentration is within or above reference interval. Client-owned cats and dogs were divided into 3 respective groups: acute limb paralysis because of ATE (22 cats and 9 dogs); acute limb paralysis secondary to orthopedic or neurologic conditions (nonambulatory controls; 10 cats and 11 dogs); ambulatory animals presented because of various diseases (ambulatory controls; 10 cats and 9 dogs). Prospective observational, clinical study. Systemic and local (affected limb) blood glucose concentrations were measured. Their absolute and relative differences (ΔGlu and %ΔGlu, respectively) were compared among groups. ΔGlu and %ΔGlu were significantly higher in the ATE cats and dogs groups, compared to both of their respective controls (P cats, respectively, and 1.00 and 1.00, in dogs, respectively. ΔGlu cutoffs of 30 mg/dL and 16 mg/dL, in cats and dogs, respectively, corresponded to sensitivity and specificity of 100% and 90% in cats, respectively, and 100% in dogs. ΔGlu and %ΔGlu are accurate, readily available, diagnostic markers of acute ATE in paralyzed cats and dogs. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  5. Reducing risk of closed loop control of blood glucose in artificial pancreas using fractional calculus.

    Science.gov (United States)

    Ghorbani, Mahboobeh; Bogdan, Paul

    2014-01-01

    Healthcare costs in the US are among the highest in the world. Chronic diseases such as diabetes significantly contribute to these extensive costs. Despite technological advances to improve sensing and actuation devices, we still lack a coherent theory that facilitates the design and optimization of efficient and robust medical cyber-physical systems for managing chronic diseases. In this paper, we propose a mathematical model for capturing the complex dynamics of blood glucose time series (e.g., time dependent and fractal behavior) observed in real world measurements via fractional calculus concepts. Building upon our time dependent fractal model, we propose a novel model predictive controller for an artificial pancreas that regulates insulin injection. We verify the accuracy of our controller by comparing it to conventional non-fractal models using real world measurements and show how the nonlinear optimal controller based on fractal calculus concepts is superior to non-fractal controllers in terms of average risk index and prediction accuracy.

  6. Noninvasive monitoring of blood glucose concentration in diabetic patients with optical coherence tomography

    Science.gov (United States)

    Lan, Y. T.; Kuang, Y. P.; Zhou, L. P.; Wu, G. Y.; Gu, P. C.; Wei, H. J.; Chen, K.

    2017-03-01

    Optical coherence tomography (OCT) has been used to noninvasively monitor the blood glucose concentration (BGC) in healthy subjects with good accuracy and acceptable specificity. Based on this, the paper further considered the possibility of OCT in noninvasive monitoring BGC in diabetic patients. The OCT signal slope (OCTSS) changed with variation of BGC. The correlation coefficient R between BGC and OCTSS in diabetic patients was 0.91; while the correlation coefficient R in healthy volunteers was 0.78. Thus, a better linear dependence of OCTSS on BGC in diabetic patients was presented in the experiment. The results showed that the capability and accuracy of OCT in noninvasive monitoring BGC of diabetic patients, and the noninvasive monitoring BGC in diabetic patients may be better than the monitoring in the healthy subjects.

  7. Comprehensive experiment-clinical biochemistry: determination of blood glucose and triglycerides in normal and diabetic rats.

    Science.gov (United States)

    Jiao, Li; Xiujuan, Shi; Juan, Wang; Song, Jia; Lei, Xu; Guotong, Xu; Lixia, Lu

    2015-01-01

    For second year medical students, we redesigned an original laboratory experiment and developed a combined research-teaching clinical biochemistry experiment. Using an established diabetic rat model to detect blood glucose and triglycerides, the students participate in the entire experimental process, which is not normally experienced during a standard clinical biochemistry exercise. The students are not only exposed to techniques and equipment but are also inspired to think more about the biochemical mechanisms of diseases. When linked with lecture topics about the metabolism of carbohydrates and lipids, the students obtain a better understanding of the relevance of abnormal metabolism in relation to diseases. Such understanding provides a solid foundation for the medical students' future research and for other clinical applications.

  8. Blood glucose control in patients with severe sepsis and septic shock

    Institute of Scientific and Technical Information of China (English)

    Hiroyuki Hirasawa; Shigeto Oda; Masataka Nakamura

    2009-01-01

    The main pathophysiological feature of sepsis is the uncontrollable activation of both pro- and anti-inflammatory responses arising from the overwhelming production of mediators such as pro- and anti-inflammatory cytokines. Such an uncontrollable inflammatory response would cause many kinds of metabolic derangements.One such metabolic derangement is hyperglycemia.Accordingly, control of hyperglycemia in sepsis is considered to be a very effective therapeutic approach. However, despite the initial enthusiasm, recent studies reported that tight glycemic control with intensive insulin therapy failed to show a beneficial effect on mortality of patients with severe sepsis and septic shock. One of the main reasons for this disappointing result is the incidence of harmful hypoglycemia during intensive insulin therapy. Therefore, avoidance of hypoglycemia during intensive insulin therapy may be a key issue in effective tight glycemic control.It is generally accepted that glycemic control aimed at a blood glucose level of 80-100 mg/dL, as initially proposed by van den Berghe, seems to be too tight and that such a level of tight glycemic control puts septic patients at increased risk of hypoglycemia. Therefore,now many researchers suggest less strict glycemic control with a target blood glucose level of 140-180 mg/dL.Also specific targeting of glycemic control in diabetic patients should be considered. Since there is a significant correlation between success rate of glycemic control and the degree of hypercytokinemia in septic patients,some countermeasures to hypercytokinemia may be an important aspect of successful glycemic control. Thus,in future, use of an artificial pancreas to avoid hypoglycemia during insulin therapy, special consideration of septic diabetic patients, and control of hypercytokinemia should be considered for more effective glycemic control in patients with severe sepsis and septic shock.

  9. Effects of Flavonoids in Morus indica on Blood Lipids and Glucose in Hyperlipidemia-diabetic Rats

    Institute of Scientific and Technical Information of China (English)

    MA Dong-qing; JIANG Zheng-ju; XU Shi-qiang; YU Xing; HU Xia-min; PAN Hong-yan

    2012-01-01

    Objective To investigate the effect and possible mechanism of flavonoids extracted from Morus indica(FMI)on blood lipids and glucose.Methods The experimental hyperlipidemia-diabetic rats were induced by high-fat diet(HFD)and low dose of Streptozotocin(STZ).Flavonoids-treated rats were pretreated with FMI(50,100,and 200 mg/kg).The plasma,skeletal muscle,and livers were isolated for biochemical assays,HE staining,immunohistochemistry,and Western blotting analysis.Results The results showed that the body weight in flavonoidstreated(100 and 200 mg/kg)rats was reduced(P<0.05,0.01)compared to HFD-fed rats.FMI obviously reduced total cholesterol(P<0.01),triglycerides(P<0.05),and low-density lipoprotein cholesterol(P<0.05),increased high-density lipoprotein(P<0.05),and significantly decreased the atherosclerosis index(P<0.01);FMI(100 and 200 mg/kg)also down-regulated the elevation of blood glucose induced by STZ(P<0.05,0.01);At the meantime,FMI increased hepatic superoxide dismutase(SOD)activity and reduced hepatic malondialdehyde(MDA)content obviously.In addition,the results showed that the expression of hepatic CYP2E1 was markedly decreased while the expression of GLUT-4 in skeletal muscles was increased by FMI.Conclusion The above results demonstrate that the effect of FMI is related to its up-regulation of hepatic SOD activity,reduction of hepatic MDA content,down-regulation of hepatic CYP2E1 expression,and increase of GLUT-4 expression in skeletal muscle,which suggests that FMI may prevent or improve hyperlipidemia and hyperglycemia caused by an excessive HFD.

  10. Blood glucose screening rates among Minnesota adults with hypertension, Behavioral Risk Factor Surveillance System, 2011.

    Science.gov (United States)

    Kidney, Renée S M; Peacock, James M; Smith, Steven A

    2014-11-26

    Many US adults have multiple chronic conditions, and hypertension and diabetes are among the most common dyads. Diabetes and prediabetes prevalence are increasing, and both conditions negatively affect cardiovascular health. Early diagnosis and treatment of diabetes and prediabetes can benefit people with hypertension by preventing cardiovascular complications. We analyzed 2011 Minnesota Behavioral Risk Factor Surveillance System data to describe the proportion of adults with hypertension screened for diabetes according to US Preventive Services Task Force Recommendations for blood glucose testing. Covariates associated with lower odds of recent screening among adults without diabetes were determined using weighted logistic regression. Of Minnesota adults with self-reported hypertension, 19.6% had a diagnosis of diabetes and 10.7% had a diagnosis of prediabetes. Nearly one-third of adults with hypertension without diabetes had not received blood glucose screening in the past 3 years. Factors associated with greater odds of not being screened in multivariable models included being aged 18 to 44 years (adjusted odds ratio [AOR], 1.77; 95% confidence interval [CI], 1.23-2.55); being nonobese, with stronger effects for normal body mass index; having no check-up in the past 2 years (AOR, 2.49; 95% CI, 1.49-4.17); having hypertension treated with medication (AOR, 2.01; 95% CI, 1.49-2.71); and completing less than a college degree (AOR, 1.45; 95% CI, 1.14-1.84). Excluding respondents with prediabetes or those not receiving a check-up did not change the results. Failure to screen among providers and failure to understand the importance of screening among individuals with hypertension may mean missed opportunities for early detection, clinical management, and prevention of diabetes.

  11. Techniques of monitoring blood glucose during pregnancy for women with pre-existing diabetes.

    Science.gov (United States)

    Moy, Foong Ming; Ray, Amita; Buckley, Brian S; West, Helen M

    2017-06-11

    Self-monitoring of blood glucose (SMBG) is recommended as a key component of the management plan for diabetes therapy during pregnancy. No existing systematic reviews consider the benefits/effectiveness of various techniques of blood glucose monitoring on maternal and infant outcomes among pregnant women with pre-existing diabetes. The effectiveness of the various monitoring techniques is unclear. To compare techniques of blood glucose monitoring and their impact on maternal and infant outcomes among pregnant women with pre-existing diabetes. We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (30 November 2016), searched reference lists of retrieved studies and contacted trial authors. Randomised controlled trials (RCTs) and quasi-RCTs comparing techniques of blood glucose monitoring including SMBG, continuous glucose monitoring (CGM) or clinic monitoring among pregnant women with pre-existing diabetes mellitus (type 1 or type 2). Trials investigating timing and frequency of monitoring were also included. RCTs using a cluster-randomised design were eligible for inclusion but none were identified. Two review authors independently assessed study eligibility, extracted data and assessed the risk of bias of included studies. Data were checked for accuracy. The quality of the evidence was assessed using the GRADE approach. This review update includes at total of 10 trials (538) women (468 women with type 1 diabetes and 70 women with type 2 diabetes). The trials took place in Europe and the USA. Five of the 10 included studies were at moderate risk of bias, four studies were at low to moderate risk of bias, and one study was at high risk of bias. The trials are too small to show differences in important outcomes such as macrosomia, preterm birth, miscarriage or death of baby. Almost all the reported GRADE outcomes were assessed as being very low-quality evidence. This was due to design limitations in the studies, wide confidence intervals, small

  12. Are Tubes Containing Sodium Fluoride Still Needed for the Measurement of Blood Glucose in Hospital Laboratory Practice?

    Directory of Open Access Journals (Sweden)

    Amira Al-Kharusi

    2014-11-01

    Full Text Available Objectives: To compare glucose values obtained using sodium flouride (NaF tubes and serum separation tubes (SST in a tertiary care hospital laboratory setting.  Methods: This study was conducted at the Clinical Biochemistry Laboratory, Royal Hospital, Oman. During the study period (1 September–30 November 2013, 50 pairs (one NaF tube and one SST of patient’s blood specimens were randomly collected. Following separation of plasma (NaF tubes and serum (SST, glucose concentrations were measured by hexokinase assay using the Architect c8000. Fifteen pairs of these tubes were kept in the refrigerator at 4°C and plasma/serum glucose concentrations were measured daily up to seven days after collection.  Results: Comparing plasma (NaF and serum (SST results of glucose values (n=50 showed an average difference of 0.00mmol/L (range -0.60 to +0.60mmol/L. Bland Altman analysis gave a non-significant constant bias of 0.10 ±0.195mmol/L (bias ±SD. Pearson correlation between plasma (NaF and serum (SST glucose concentrations revealed a significant correlation approaching unity with r2= 0.9991. No significant differences in glucose values were noted for both plasma and serum in 15 pairs of NaF and SST tubes when analyzed seven days following refrigeration. Hemolysis was observed in five (10% NaF tubes compared with two (4% SST.  Conclusion: There is no difference in glucose values collected from plasma NaF tubes or serum SST, and so SST can be used in hospital laboratory settings as there are practical advantages, including cost-effectiveness and reduction in blood volume drawn when utilizing these tubes for glucose and other tests from a single blood collection tube.

  13. Changes in blood glucose, plasma non-esterified fatty acids and insulin in pregnant and non-pregnant goats.

    Science.gov (United States)

    Khan, J R; Ludri, R S

    2002-02-01

    The blood glucose and the plasma non-esterified fatty acids (NEFA) and insulin concentrations were estimated in jugular blood samples from 18 Alpine x Beetal and Sannen x Beetal goats during pregnancy and compared with samples from non-pregnant goats and from goats during the periparturient period. The blood glucose levels in the pregnant goats rose to a peak of about 60 +/- 1.36 mg/ml at 42-56 days and then declined to about 46 +/- 2.37 mg/ml at 112-126 days. In non-pregnant goats, the blood glucose levels were significantly (p goats, except between days 42 and 70 (59 +/- 1.36 mg/ml). On the day of kidding, the levels declined significantly (p goats from days 56 to 126. The NEFA concentration increased on the day of kidding, followed by a transient fall by day 3. The plasma insulin concentration was usually higher in pregnant than in non-pregnant goats, except between days 56 and 70 and from day 126 onwards. The insulin concentration fell late in pregnancy, but there was a transient increase 2 days after parturition. The blood glucose and plasma NEFA concentrations can be used as indices of nutritional status during pregnancy in goats.

  14. Study of the Effect of Garlic on Serum Lipids and Blood Glucose Levels in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    M Afkhami - Ardekani

    2005-04-01

    Full Text Available Introduction: Hyperlipidemia and diabetes are common risk factors for ischemic heart disease, which is the main cause of mortality in diabetic patients. Strict control of blood glucose and other risk factors in diabetics has led to prevention of complications. Garlic has received particular attention for control of blood glucose and decrease in blood lipid levels. At present, several studies have been carried out in order to prove advantages of garlic. Methods: In this study, effects of garsin (a derivative of garlic present in our country on serum lipids and blood glucose levels in diabetes mellitus type 2 patients was observed. Forty-five type 2 diabetics who had hyperlipidemia were selected. These patients were kept on treatment with 3 tablets of Garsin / day for 4 weeks. Serum lipids and blood glucose levels were measured prior to and at the end of treatment. Results: Relationship between sex and response to treatment in this study was meaningful, such that Gsarsin led to decrease in LDL-C and increase in HDL in females. Conclusion: Therefore, Garsin can be used as an adjunct to treatment in diabetes type 2 patients with hyperlipidemia.

  15. Glucose buffer is suitable for blood group conversion with α-N acetylgalactosaminidase and α-galactosidase.

    Science.gov (United States)

    Gao, Hong-Wei; Li, Su-Bo; Bao, Guo-Qiang; Zhang, Xue; Li, Hui; Wang, Ying-Li; Tan, Ying-Xia; Ji, Shou-Ping; Gong, Feng

    2014-01-01

    It is well known that the buffer plays a key role in the enzymatic reaction involved in blood group conversion. In previous study, we showed that a glycine buffer is suitable for A to O or B to O blood group conversion. In this study, we investigated the use of 5% glucose and other buffers for A to O or B to O blood group conversion by α-N-acetylgalactosaminidase or α-galactosidase. We compared the binding ability of α-N-acetylgalactosaminidase/α-galactosidase with red blood cells (RBC) in different reaction buffers, such as normal saline, phosphate-buffered saline (PBS), a disodium hydrogen phosphate-based buffer (PCS), and 5% commercial glucose solution. The doses of enzymes necessary for the A/B to O conversion in different reaction buffers were determined and compared. The enzymes' ability to bind to RBC was evaluated by western blotting, and routine blood typing and fluorescence activated cell sorting was used to evaluate B/A to O conversion efficiency. The A to O conversion efficiency in glucose buffer was similar to that in glycine buffer with the same dose (>0.06 mg/mL pRBC). B to O conversion efficiency in glucose buffer was also similar to that in glycine buffer with the same dose (>0.005 mg/mL pRBC). Most enzymes could bind with RBC in glycine or glucose buffer, but few enzymes could bind with RBC in PBS, PCS, or normal saline. These results indicate that 5% glucose solution provides a suitable condition for enzymolysis, especially for enzymes combining with RBC. Meanwhile, the conversion efficiency of A/B to O was similar in glucose buffer and glycine buffer. Moreover, 5% glucose solution has been used for years in venous transfusion, it is safe for humans and its cost is lower. Our results do, therefore, suggest that 5% glucose solution could become a novel suitable buffer for A/B to O blood group conversion.

  16. Blood constituents trigger brain swelling, tissue death, and reduction of glucose metabolism early after acute subdural hematoma in rats.

    Science.gov (United States)

    Baechli, Heidi; Behzad, Melika; Schreckenberger, Matthias; Buchholz, Hans-Georg; Heimann, Axel; Kempski, Oliver; Alessandri, Beat

    2010-03-01

    Outcome from acute subdural hematoma is often worse than would be expected from the pure increase of intracranial volume by bleeding. The aim was to test whether volume-independent pathomechanisms aggravate damage by comparing the effects of blood infusion with those of an inert fluid, paraffin oil, on intracranial pressure (ICP), cerebral perfusion pressure (CPP), local cerebral blood flow (CBF), edema formation, glucose metabolism ([18F]-deoxyglucose, MicroPET ), and histological outcome. Rats were injured by subdural infusion of 300 muL venous blood or paraffin. ICP, CPP, and CBF changes, assessed during the first 30 mins after injury, were not different between the injury groups at most time points (n=8 per group). Already at 2 h after injury, blood caused a significantly more pronounced decrease in glucose metabolism in the injured cortex when compared with paraffin (P<0.001, n=5 per group). Ipsilateral brain edema did not differ between groups at 2 h, but was significantly more pronounced in the blood-treated groups at 24 and 48 h after injury (n=8 per group). These changes caused a 56.2% larger lesion after blood when compared with paraffin (48.1+/-23.0 versus 21.1+/-11.8 mm(3); P<0.02). Blood constituent-triggered pathomechanisms aggravate the immediate effects due to ICP, CPP, and CBF during hemorrhage and lead to early reduction of glucose metabolism followed by more severe edema and histological damage.

  17. The impact of brief high-intensity exercise on blood glucose levels

    Directory of Open Access Journals (Sweden)

    Adams OP

    2013-02-01

    Full Text Available O Peter AdamsFaculty of Medical Sciences, the University of the West Indies, Cave Hill Campus, St Michael, BarbadosBackground: Moderate-intensity exercise improves blood glucose (BG, but most people fail to achieve the required exercise volume. High-intensity exercise (HIE protocols vary. Maximal cycle ergometer sprint interval training typically requires only 2.5 minutes of HIE and a total training time commitment (including rest and warm up of 25 minutes per session. The effect of brief high-intensity exercise on blood glucose levels of people with and without diabetes is reviewed.Methods: HIE (≥80% maximal oxygen uptake, VO2max studies with ≤15 minutes HIE per session were reviewed.Results: Six studies of nondiabetics (51 males, 14 females requiring 7.5 to 20 minutes/week of HIE are reviewed. Two weeks of sprint interval training increased insulin sensitivity up to 3 days postintervention. Twelve weeks near maximal interval running (total exercise time 40 minutes/week improved BG to a similar extent as running at 65% VO2max for 150 minutes/week. Eight studies of diabetics (41 type 1 and 22 type 2 subjects were reviewed. Six were of a single exercise session with 44 seconds to 13 minutes of HIE, and the others were 2 and 7 weeks duration with 20 and 2 minutes/week HIE, respectively. With type 1 and 2 diabetes, BG was generally higher during and up to 2 hours after HIE compared to controls. With type 1 diabetics, BG decreased from midnight to 6 AM following HIE the previous morning. With type 2 diabetes, a single session improved postprandial BG for 24 hours, while a 2-week program reduced the average BG by 13% at 48 to 72 hours after exercise and also increased GLUT4 by 369%.Conclusion: Very brief HIE improves BG 1 to 3 days postexercise in both diabetics and nondiabetics. HIE is unlikely to cause hypoglycemia during and immediately after exercise. Larger and longer randomized studies are needed to determine the safety, acceptability, long

  18. Effect of local corticosteroid injection of the hand and wrist on blood glucose in patients with diabetes mellitus.

    Science.gov (United States)

    Catalano, Louis W; Glickel, Steven Z; Barron, O Alton; Harrison, Richard; Marshall, Astrid; Purcelli-Lafer, Marissa

    2012-12-01

    Locally administered corticosteroids are a common therapy in many hand and wrist disorders. Corticosteroids pose a theoretical risk to patients with diabetes mellitus by potentially raising blood glucose to hyperglycemic levels. Although oral corticosteroids are known to have an effect on blood glucose control, limited data exist on extra-articular administration. The purpose of this study was to examine the systemic impact of extra-articularly administered corticosteroids in the hand and wrist on serum glucose concentration in patients with diabetes mellitus.Twenty-three patients with diabetes mellitus received a 1-mL triamcinolone acetonide injection for de Quervain's tenosynovitis, trigger finger, flexor carpi ulnaris tendonitis, or carpal tunnel syndrome. Patients recorded their daily morning blood glucose levels for 1 week before injection and for 4 weeks after injection. Average blood glucose levels increased slightly from baseline after injection, reaching statistical significance 1, 5, and 6 days after injection, but were not clinically significant (average increase, 14.2, 9.7, and 32.7 mg/dL, respectively). Isolated increases more than 2 times the standard deviation of preinjection values occurred at least once in the majority of patients. The frequency of hyperglycemic episodes increased after injection, but the proportions of patients with at least 1 hyperglycemic episode before and after injection were not significantly different.These results suggest that local corticosteroid injections are a clinically safe treatment option for inflammatory processes of the hand and wrist in patients with diabetes mellitus. On average, patients experienced slight increases in blood glucose after receiving an injection. Most experienced isolated increases substantially beyond baseline and isolated hyperglycemic effects, but these did not pose an apparent clinical risk.

  19. Relationships between body weight, fasting blood glucose concentration, sex and age in tree shrews (Tupaia belangeri chinensis).

    Science.gov (United States)

    Wu, X; Chang, Q; Zhang, Y; Zou, X; Chen, L; Zhang, L; Lv, L; Liang, B

    2013-12-01

    The tree shrew (Tupaia belangeri chinensis) is a squirrel-like lower primate or a close relative of primates, commonly used as an animal model in biomedical research. Despite more than three decades of usage in research, the clear relationships between body weight, fasting blood glucose concentration, sex and age among tree shrews remain unclear. Based on an investigation of 992 tree shrews (454 males and 538 females) aged between 4 months and 4 years old, we found that male tree shrews have significantly higher body weight and fasting blood glucose concentration than female tree shrews (p < 0.001). The concentration of fasting blood glucose slightly increased with body weight in males (r = 0.152, p < 0.001). Meanwhile, in females, the body weight, concentration of fasting blood glucose and waist circumference positively increased with age (p < 0.001). Additionally, 17 tree shrews with Lee index [body weight (g)*0.33*1000/body length (cm)] above 290 had significantly higher body weight, waist circumference and glycated haemoglobin A1c (HbA1c) than non-obese tree shrews with a Lee index score below 290 (p < 0.001). Interestingly, 6 of 992 tree shrews (three males and three females, 2-4 years old) displayed impaired plasma triglycerides, HbA1c, low-density lipoprotein and oral glucose tolerance test, suggestive of the early symptoms of metabolic syndrome. This study provides the first clear relationships between body weight, fasting blood glucose concentration, sex and age in tree shrews, further improving our understanding of this relationship in metabolic syndrome (MetS). Given the similarity of tree shrews to humans and non-human primates, this finding supports their potential use as an animal model in the research of MetS.

  20. Toothbrushing, Blood Glucose and HbA1c: Findings from a Random Survey in Chinese Population.

    Science.gov (United States)

    Su, Lingyu; Liu, Wenzhao; Xie, Bingwu; Dou, Lei; Sun, Jun; Wan, Wenjuan; Fu, Xiaoming; Li, Guangyue; Huang, Jiao; Xu, Ling

    2016-07-07

    Both diabetes and periodontal disease are prevalent in China. Poor oral hygiene practice is the major cause of periodontal disease. An association between oral hygiene practice and blood glucose level was reported in individuals with diabetes, but not in the general population. We examined the association in a population-based random survey recruiting 2,105 adults without previously diagnosed diabetes in Chongqing city, China. Plasma glucose and hemoglobin A1c (HbA1c) were measured, and a 2-hour oral glucose tolerance test was conducted for each respondent. Self-reported toothbrushing frequency was used as a proxy for oral hygiene practice. In a linear model controlling for potential confounders (demographic characteristics, socio-economic status, lifestyle risk factors, BMI, dental visit frequency, etc.), urban residents who barely brushed their teeth had an increase of 0.50 (95% CI: 0.10-0.90) mmol/L in fasting plasma glucose, and an increase of 0.26% (0.04-0.47%) in HbA1c, relative to those brushing ≥twice daily; for rural residents, the effects were 0.26 (0.05-0.48) mmol/L in fasting plasma glucose and 0.20% (0.09-0.31%) in HbA1c. Individuals with better oral practice tended to have lower level of blood glucose and HbA1c. Establishing good oral health behavioral habits may be conducive to diabetes prevention and control in the general population.

  1. Effects of enalapril, losartan, and verapamil on blood pressure and glucose metabolism in the Cohen-Rosenthal diabetic hypertensive rat.

    Science.gov (United States)

    Rosenthal, T; Erlich, Y; Rosenmann, E; Cohen, A

    1997-06-01

    We undertook the present study to examine the effect of the angiotensin-converting enzyme inhibitor enalapril, the angiotensin II antagonist losartan, and calcium antagonist verapamil on systolic pressure and spontaneous blood glucose levels in rats from the Cohen-Rosenthal diabetic hypertensive strain. Genetic hypertension and diabetes developed in this strain after crossbreeding of Cohen diabetic and spontaneously hypertensive rats. The new rat strain was fed their usual copper-poor sucrose diet, which is essential for the development of this model, and for 4 weeks received either enalapril, losartan, or verapamil. Systolic pressure was reduced significantly compared with controls in all treated groups. Chronic treatment with enalapril or verapamil, but not with losartan, succeeded in lowering spontaneous blood glucose, indicating improved diabetic control. Data suggest that angiotensin-converting enzyme inhibition by enalapril, but not angiotensin II antagonism by losartan, can improve glucose metabolism in addition to its hypotensive effect in a genetic diabetic hypertensive rat strain. This confirms that the drop in glucose with converting enzyme inhibition is highly dependent on bradykinin accumulation. Data further suggest that calcium channel blockade by verapamil can also improve glucose metabolism. The question remains whether the reduction in glucose by verapamil was a result of inhibition of glucogenesis.

  2. Reliable glucose monitoring by ex-vivo blood microdialysis and infrared spectrometry for patients in critical care

    Science.gov (United States)

    Vahlsing, Thorsten; Delbeck, Sven; Budde, Janpeter; Ihrig, Dieter; Leonhardt, Steffen; Heise, H. Michael

    2017-02-01

    Blood glucose monitoring has been realised by biosensors in combination with micro-dialysis, using either subcutaneously or intravascularly implanted catheters. Another alternative is ex-vivo micro-dialysis of continuously sampled heparinized whole blood available from the patient even under critical care conditions. However, most devices suffer from inaccuracies due to variable recovery rates. Infrared spectrometry has been suggested for analyte quantification, since besides glucose other clinically relevant analytes can be simultaneously determined that are, e.g., important for intensive care patients. Perfusates with acetate and mannitol have been investigated as recovery markers (internal standards). In contrast to the previously used acetate, an almost linear dependency between mannitol loss and glucose recovery was observed for micro-dialysis of glucose spiked aqueous albumin solutions or porcine heparinized whole blood when testing flat membranes within a custom-made micro-dialysator. By this, a straightforward compensation of any dialysis recovery rate variation during patient monitoring is possible. The combination of microdialysis with infrared spectrometry provides a calibration-free assay for accurate continuous glucose monitoring, as reference spectra of dialysate components can be a-priori allocated.

  3. Factors affecting initial training success of blood glucose testing in captive chimpanzees (Pan troglodytes).

    Science.gov (United States)

    Reamer, Lisa A; Haller, Rachel L; Thiele, Erica J; Freeman, Hani D; Lambeth, Susan P; Schapiro, Steven J

    2014-01-01

    Type 2 diabetes can be a problem for captive chimpanzees. Accurate blood glucose (BG) readings are necessary to monitor and treat this disease. Thus, obtaining voluntary samples from primates through positive reinforcement training (PRT) is critical. The current study assessed the voluntary participation of 123 chimpanzees in BG sampling and investigated factors that may contribute to individual success. All subjects participate in regular PRT sessions as part of a comprehensive behavioral management program. Basic steps involved in obtaining BG values include: voluntarily presenting a finger/toe; allowing digit disinfection; holding for the lancet device; and allowing blood collection onto a glucometer test strip for analysis. We recorded the level of participation (none, partial, or complete) when each chimpanzee was first asked to perform the testing procedure. Nearly 30% of subjects allowed the entire procedure in one session, without any prior specific training for the target behavior. Factors that affected this initial successful BG testing included sex, personality (chimpanzees rated higher on the factor "openness" were more likely to participate with BG testing), and past training performance for "present-for-injection" (chimpanzees that presented for their most recent anesthetic injection were more likely to participate). Neither age, rearing history, time since most recent anesthetic event nor social group size significantly affected initial training success. These results have important implications for captive management and training program success, underlining individual differences in training aptitude and the need for developing individual management plans in order to provide optimal care and treatment for diabetic chimpanzees in captivity.

  4. The effect of polyphenol-rich dark chocolate on fasting capillary whole blood glucose, total cholesterol, blood pressure and glucocorticoids in healthy overweight and obese subjects.

    Science.gov (United States)

    Almoosawi, Suzana; Fyfe, Lorna; Ho, Clement; Al-Dujaili, Emad

    2010-03-01

    Numerous studies indicate that polyphenol-rich chocolate reduces fasting blood glucose, blood pressure (BP) and total cholesterol in healthy individuals and hypertensives with or without glucose intolerance. The aim of the present study was to investigate the effect of two doses of polyphenol-rich dark chocolate (DC) on fasting capillary whole blood glucose, total cholesterol and BP and to examine whether improvements in these parameters are associated with changes in adrenocorticoid excretion in overweight and obese individuals. The study used a randomised, single-blind, cross-over design where fourteen overweight and obese subjects were randomised to either take 20 g DC with 500 mg polyphenols then 20 g DC with 1000 mg polyphenols or vice-versa. Participants followed each diet for 2 weeks separated by a 1-week washout period. It was observed that the 500 mg polyphenol dose was equally effective in reducing fasting blood glucose levels, systolic BP (SBP) and diastolic BP (DBP) as the 1000 mg polyphenol dose suggesting that a saturation effect might occur with increasing dose of polyphenols. There was also a trend towards a reduction in urinary free cortisone levels with both groups although it did not reach statistical significance. No changes in anthropometrical measurements were seen. We suggest that more research is required to investigate the mechanism(s) by which polyphenol-rich foods influence health.

  5. [Advances of the mechanism study on berberine in the control of blood glucose and lipid as well as metabolism disorders].

    Science.gov (United States)

    Shen, Ning; Li, Cai-Na; Huan, Yi; Shen, Zhu-Fang

    2010-06-01

    Berberine, an isoquinoline alkaloid isolated from some Chinese medicinal herbs such as Coptidis rhizoma, has been used for the treatment of diarrhea and other gastrointestinal infections as an antibacterial drug in Chinese medicine. In recent years, it was reported to have beneficial effects on the metabolism disorders states of diabetes. The mechanisms involve many aspects of the diabetes, including regulating the blood cholesterol and triglyceride, lowering blood glucose, ameliorating the insulin resistant state and influencing the function of the pancreatic beta cell.

  6. High glucose induces the expression of osteopontin in blood vessels in vitro and in vivo.

    Science.gov (United States)

    Li, Tianjia; Ni, Leng; Liu, Xinnong; Wang, Zhanqi; Liu, Changwei

    2016-11-11

    Osteopontin (OPN) is involved in mineral metabolism and the inflammatory response while diabetes mellitus is associated with severe and extensive vascular calcification. Therefore, we speculated that OPN could be a key factor in the calcification and dysfunction of blood vessels exposed to high glucose. To identify the relationship between high glucose and OPN, we used high glucose medium to stimulate smooth muscle cells (SMCs) and vascular endothelial cells (VECs) in vitro and diabetic rats for in vivo analyses. As assessed by flow cytometry and western blots, SMC and VEC apoptosis levels increased with high glucose. Potassium and calcium uptake by cells were also increased with high glucose. These findings demonstrated the relationship between mineral metabolism and high glucose. Western blot and quantitative real time polymerase chain reaction analyses demonstrated that OPN increased in vitro with high glucose stimulation. The inflammatory factor ICAM1 and the inhibitory phosphorylation of endothelial nitric-oxide synthase (eNOS) (Thr495) were also upregulated by high glucose. In contrast, the anti-inflammatory factor Nrf2 and the activating phosphorylation of eNOS (Ser1177) were downregulated. Similar to the change of OPN, phosphorylated P38 was increased with high glucose. SB203580, an inhibitor of P38 phosphorylation, downregulated the expression of OPN and related inflammatory factors. Additionally, OPN was increased in the aortas and plasma of diabetic rats. In conclusion, our findings demonstrate that high glucose can induce the expression of OPN, which may be a key factor in the calcification and dysfunction of the vascular wall in diabetes.

  7. Clinical significance of serum carbohydrate antigen 19-9 and its relationship with blood glucose in patients with type 2 diabetes

    Institute of Scientific and Technical Information of China (English)

    武秀玲

    2013-01-01

    Objective To study the relationship between serum carbohydrate antigen 19-9 (CA19-9) and blood glucose level in patients with type 2 diabetes (T2DM) .Methods Totally 784 T2DM patients and 197 healthy controls were enrolled in this study.Age,duration,body mass index (BMI) ,systolic blood pressure (SBP) ,diastolic blood pressure (DBP) ,levels of fasting blood glucose (FBG) ,postprandial blood glucose (PBG) ,hemoglobin A1c (HbA1c) ,total cholesterol (TC) ,triglyceride (TG) ,

  8. Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.

    Science.gov (United States)

    Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji

    2016-02-01

    A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.

  9. [The net analyte preprocessing combined with radial basis partial least squares regression applied in noninvasive measurement of blood glucose].

    Science.gov (United States)

    Li, Qing-Bo; Huang, Zheng-Wei

    2014-02-01

    In order to improve the prediction accuracy of quantitative analysis model in the near-infrared spectroscopy of blood glucose, this paper, by combining net analyte preprocessing (NAP) algorithm and radial basis functions partial least squares (RBFPLS) regression, builds a nonlinear model building method which is suitable for glucose measurement of human, named as NAP-RBFPLS. First, NAP is used to pre-process the near-infrared spectroscopy of blood glucose, in order to effectively extract the information which only relates to glucose signal from the original near-infrared spectra, so that it could effectively weaken the occasional correlation problems of the glucose changes and the interference factors which are caused by the absorption of water, albumin, hemoglobin, fat and other components of the blood in human body, the change of temperature of human body, the drift of measuring instruments, the changes of measuring environment, and the changes of measuring conditions; and then a nonlinear quantitative analysis model is built with the near-infrared spectroscopy data after NAP, in order to solve the nonlinear relationship between glucose concentrations and near-infrared spectroscopy which is caused by body strong scattering. In this paper, the new method is compared with other three quantitative analysis models building on partial least squares (PLS), net analyte preprocessing partial least squares (NAP-PLS) and RBFPLS respectively. At last, the experimental results show that the nonlinear calibration model, developed by combining NAP algorithm and RBFPLS regression, which was put forward in this paper, greatly improves the prediction accuracy of prediction sets, and what has been proved in this paper is that the nonlinear model building method will produce practical applications for the research of non-invasive detection techniques on human glucose concentrations.

  10. Short-Term High-Intensity Interval Training on Body Composition and Blood Glucose in Overweight and Obese Young Women.

    Science.gov (United States)

    Kong, Zhaowei; Sun, Shengyan; Liu, Min; Shi, Qingde

    2016-01-01

    This study was to determine the effects of five-week high-intensity interval training (HIIT) on cardiorespiratory fitness, body composition, blood glucose, and relevant systemic hormones when compared to moderate-intensity continuous training (MICT) in overweight and obese young women. Methods. Eighteen subjects completed 20 sessions of HIIT or MICT for five weeks. HIIT involved 60 × 8 s cycling at ~90% of peak oxygen consumption ([Formula: see text]) interspersed with 12 s recovery, whereas MICT involved 40-minute continuous cycling at 65% of [Formula: see text]. [Formula: see text], body composition, blood glucose, and fasting serum hormones, including leptin, growth hormone, testosterone, cortisol, and fibroblast growth factor 21, were measured before and after training. Results. Both exercise groups achieved significant improvements in [Formula: see text] (+7.9% in HIIT versus +11.7% in MICT) and peak power output (+13.8% in HIIT versus +21.9% in MICT) despite no training effects on body composition or the relevant systemic hormones. Blood glucose tended to be decreased after the intervention (p = 0.062). The rating of perceived exertion in MICT was higher than that in HIIT (p = 0.042). Conclusion. Compared with MICT, short-term HIIT is more time-efficient and is perceived as being easier for improving cardiorespiratory fitness and fasting blood glucose for overweight and obese young women.

  11. Short-Term High-Intensity Interval Training on Body Composition and Blood Glucose in Overweight and Obese Young Women

    Directory of Open Access Journals (Sweden)

    Zhaowei Kong

    2016-01-01

    Full Text Available This study was to determine the effects of five-week high-intensity interval training (HIIT on cardiorespiratory fitness, body composition, blood glucose, and relevant systemic hormones when compared to moderate-intensity continuous training (MICT in overweight and obese young women. Methods. Eighteen subjects completed 20 sessions of HIIT or MICT for five weeks. HIIT involved 60 × 8 s cycling at ~90% of peak oxygen consumption (V˙O2peak interspersed with 12 s recovery, whereas MICT involved 40-minute continuous cycling at 65% of V˙O2peak. V˙O2peak, body composition, blood glucose, and fasting serum hormones, including leptin, growth hormone, testosterone, cortisol, and fibroblast growth factor 21, were measured before and after training. Results. Both exercise groups achieved significant improvements in V˙O2peak (+7.9% in HIIT versus +11.7% in MICT and peak power output (+13.8% in HIIT versus +21.9% in MICT despite no training effects on body composition or the relevant systemic hormones. Blood glucose tended to be decreased after the intervention (p=0.062. The rating of perceived exertion in MICT was higher than that in HIIT (p=0.042. Conclusion. Compared with MICT, short-term HIIT is more time-efficient and is perceived as being easier for improving cardiorespiratory fitness and fasting blood glucose for overweight and obese young women.

  12. Changes of hemoglobin content and glucose levels in the blood of Rattus norvegicus by water extracts of Azadirachta indica

    Institute of Scientific and Technical Information of China (English)

    Shori; Amal Bakr

    2012-01-01

    Presently,there is a growing interest in herbal remedies.Neem (Azadirachta indica) has been used in traditional medicine over centuries.In the present study,the effects of water extracts of Azadirachta indica seeds,stems,flowers and bark on the changes of hemoglobin content (Hb) and glucose levels in the blood of Rattus norvegicus were investigated.Different doses of A.indica water extracts of seeds,stems,flowers and bark were injected to the tested animals every 48 h for 14 days.Significant decrease in both hemoglobin content and glucose levels in the blood samples in all groups of injected rats were compared to control group.However,in all groups higher decrease was shown in the rats injected with 1 g·mL-1 ofA.indica water extracts.In addition,the present study showed no significant relationship between decreased hemoglobin content and glucose levels in blood samples,and increased doses injected.In conclusion,A.indica has the potential to decrease both hemoglobin content and blood glucose levels.

  13. Short-Term High-Intensity Interval Training on Body Composition and Blood Glucose in Overweight and Obese Young Women

    Science.gov (United States)

    Kong, Zhaowei; Sun, Shengyan; Liu, Min

    2016-01-01

    This study was to determine the effects of five-week high-intensity interval training (HIIT) on cardiorespiratory fitness, body composition, blood glucose, and relevant systemic hormones when compared to moderate-intensity continuous training (MICT) in overweight and obese young women. Methods. Eighteen subjects completed 20 sessions of HIIT or MICT for five weeks. HIIT involved 60 × 8 s cycling at ~90% of peak oxygen consumption (V˙O2peak) interspersed with 12 s recovery, whereas MICT involved 40-minute continuous cycling at 65% of V˙O2peak. V˙O2peak, body composition, blood glucose, and fasting serum hormones, including leptin, growth hormone, testosterone, cortisol, and fibroblast growth factor 21, were measured before and after training. Results. Both exercise groups achieved significant improvements in V˙O2peak (+7.9% in HIIT versus +11.7% in MICT) and peak power output (+13.8% in HIIT versus +21.9% in MICT) despite no training effects on body composition or the relevant systemic hormones. Blood glucose tended to be decreased after the intervention (p = 0.062). The rating of perceived exertion in MICT was higher than that in HIIT (p = 0.042). Conclusion. Compared with MICT, short-term HIIT is more time-efficient and is perceived as being easier for improving cardiorespiratory fitness and fasting blood glucose for overweight and obese young women.

  14. Impact of control of blood glucose level during treatment of sudden deafness in diabetics: relationship with prognosis.

    Science.gov (United States)

    Min, Sang-Ki; Shin, Ji-Ho; Chang, Mun-Young; Min, Hyun-Jin; Kim, Kyung-Soo; Lee, Sei-Young; Yang, Hoon-Shik; Hong, Young-Ho; Mun, Seog-Kyun

    2017-03-01

    The objective of this study is to investigate the impact of control of blood glucose level during treatment of sudden deafness. A retrospective study was performed involving 197 patients from January, 2011 to September, 2015. All patients were administrated prednisolone (Pharmaprednisolone tab(®), 5 mg/T; KoreaPharma) p.o under the following regimen: 60 mg/day for 4 days, 40 mg/day for 2 days, 30 mg/day for 1 day, 20 mg/day for 1 day, and 10 mg/day for 2 days. During treatment, pure tone audiometry and blood glucose level were investigated for each patient and the results were statistically analyzed. Mean hearing improvement was 19.2 dB for the non-diabetes group and 24.8 dB for the diabetes group. The greater improvement for diabetics was not statistically significant (p = 0.146). Hearing improvement was 25.1 dB for subjects with mean blood glucose 200 mg/dl; the difference was not statistically significant (p = 0.267). Mean blood glucose level was 200.8 mg/dl for subjects with hearing improvement >20 dB and 181.8 mg/dl for subjects with hearing improvement sudden deafness does not have a direct effect on prognosis.

  15. Laboratory Exercise: Study of Digestive and Regulatory Processes through the Exploration of Fasted and Postprandial Blood Glucose

    Science.gov (United States)

    Hopper, Mari K.; Maurer, Luke W.

    2013-01-01

    Digestive physiology laboratory exercises often explore the regulation of enzyme action rather than systems physiology. This laboratory exercise provides a systems approach to digestive and regulatory processes through the exploration of postprandial blood glucose levels. In the present exercise, students enrolled in an undergraduate animal…

  16. Behavioral Self-Regulation in Adolescents with Type 1 Diabetes: Negative Affectivity and Blood Glucose Symptom Perception.

    Science.gov (United States)

    Wiebe, Deborah J.; And Others

    1994-01-01

    Adolescents who were more internally focused were more able to discern which symptoms actually covaried with blood glucose (BG) fluctuations; those with higher trait anxiety tended to misattribute non-diabetes-related symptoms to BG levels. Interactions suggested those who both attend to internal physical sensations and experience-heightened…

  17. Factors affecting initial training success of blood glucose testing in captive chimpanzees (Pan troglodytes)

    DEFF Research Database (Denmark)

    Reamer, Lisa A; Haller, Rachel L; Thiele, Erica J

    2014-01-01

    Type 2 diabetes can be a problem for captive chimpanzees. Accurate blood glucose (BG) readings are necessary to monitor and treat this disease. Thus, obtaining voluntary samples from primates through positive reinforcement training (PRT) is critical. The current study assessed the voluntary parti...

  18. Effect of nondigestible oligosaccharides on large-bowel functions, blood lipid concentrations and glucose absorption in young healthy male subjects

    NARCIS (Netherlands)

    Dokkum, W. van; Wezendonk, B.; Srikumar, T.S.; Heuvel, E.G.H.M. van den

    1999-01-01

    Objective: To study the effect of the intake of 15 g nondigestible oligosaccharides per day on various parameters of large-bowel function, as well as on blood lipid concentrations and glucose absorption in man. Design: Latin square, randomized, double-blind, diet-controlled. Setting: Metabolic resea

  19. Behavioral Self-Regulation in Adolescents with Type 1 Diabetes: Negative Affectivity and Blood Glucose Symptom Perception.

    Science.gov (United States)

    Wiebe, Deborah J.; And Others

    1994-01-01

    Adolescents who were more internally focused were more able to discern which symptoms actually covaried with blood glucose (BG) fluctuations; those with higher trait anxiety tended to misattribute non-diabetes-related symptoms to BG levels. Interactions suggested those who both attend to internal physical sensations and experience-heightened…

  20. Effects of L-lysine monohydrochloride on insulin and blood glucose levels in spinal cord injured rats

    Institute of Scientific and Technical Information of China (English)

    ZHANG Tian-ling; ZHAO Yu-wu; LIU Xue-yuan; DING Su-ju

    2010-01-01

    Background Hyperglycemia in brain and spinal cord could aggravate neurologic impairment. Recent studies showed that L-lysine monohydrochlonde (LMH) could increase the insulin secretion and regulate the blood glucose level. The aim of the present study was to investigate the effects of LMH on pancreatic islet B cells, the levels of endogenous insulin and blood glucose in spinal cord injured rats.Methods Forty male Wistar rats were divided into four groups, namely, normal control group, model group, high-dose LMH group (621.5 mg/kg equal to LMH 1/8 LD50), and low-dose LMH group (310.8 mg/kg equal to LMH 1/16 LD50). The model of spinal cord injured rat was established by hemi-transection at the lower right thoracic spinal cord. LMH was administered via intraperitoneal injection once spinal cord injury was produced in rats. All rats were sacrificed 48 hours after spinal cord injured. The effects of LMH on pancreatic islet B cells, the content of endogenous insulin, end the level of blood glucose were observed with immunohistochemical method, radioimmunoassay method, end biochemical analyzer, respectively. Results The insulin immunohistochemical intensities of islet B cells were significantly weaker in model group then those in normal control group (P 0.05). Conclusion LMH, but dose-dependent, might participate in the regulation of pancreatic islet B cells, and then reduce the blood glucose levels in the spinal cord injured rats.

  1. Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Weerwind, P.W.; Teerenstra, S.; Brouwer, M.H.J.

    2006-01-01

    BACKGROUND: Recently, the GEM Premier blood gas analyser was upgraded to the GEM Premier 3000. In addition to pH, pCO2, pO2, Na+, K+, Ca2+, and hematocrit measurement, glucose and lactate can be measured on the GEM Premier 3000. In this prospective clinical study, the analytical performance of the

  2. Blood glucose testing and primary prevention of diabetes mellitus type 2 - evaluation of the effect of evidence based patient information

    Directory of Open Access Journals (Sweden)

    Giani Guido

    2010-01-01

    Full Text Available Abstract Background Evidence-based patient information (EBPI has been recognised as important tool for informed choice in particular in the matter of preventive options. An objective, on the best scientific evidence-based consumer information about subthreshold elevated blood glucose levels (impaired fasting glucose and impaired glucose tolerance and primary prevention of diabetes, is not available yet. Thus we developed a web-based EBPI and aim to evaluate its effects on informed decision making in people 50 years or older. Methods/Design We conduct a web-based randomised-controlled trial to evaluate the effect of information about elevated blood glucose levels and diabetes primary prevention on five specific outcomes: (i knowledge of elevated blood glucose level-related issues (primary outcome; (ii attitudes to a metabolic testing; (iii intention to undergo a metabolic testing; (iv decision conflict; (v satisfaction with the information. The intervention group receives a specially developed EBPI about subthreshold elevated blood glucose levels and diabetes primary prevention, the control group information about this topic, available in the internet. The study population consists of people between 50 and 69 years of age without known diabetes. Participants will be recruited via the internet page of the cooperating health insurance company, Techniker Krankenkasse (TK, and the internet page of the German Diabetes Centre. Outcomes will be measured through online questionnaires. We expect better informed participants in the intervention group. Discussion The design of this study may be a prototype for other web-based prevention information and their evaluation. Trial registration Current Controlled Trial: ISRCTN22060616.

  3. Determination of the reference position in the near-infrared non-invasive blood glucose measurement in vivo

    Science.gov (United States)

    Han, Guang; Liu, Jin; Liu, Rong; Xu, Kexin

    2016-10-01

    Position-based reference measurement method is taken as one of the most promising method in non-invasive measurement of blood glucose based on spectroscopic methodology. Selecting an appropriate source-detector separation as the reference position is important for deducting the influence of background change and reducing the loss of useful signals. Our group proposed a special source-detector separation named floating-reference position where the signal contains only background change, that is to say, the signal at this source-detector separation is uncorrelated with glucose concentration. The existence of floating-reference position has been verified in a three layer skin by Monte Carlo simulation and in the in vitro experiment. But it is difficult to verify the existence of floating-reference position on the human body because the interference is more complex during in vivo experiment. Aiming at this situation, this paper studies the determination of the best reference position on human body by collecting signals at several source-detector separations on the palm and measuring the true blood glucose levels during oral glucose tolerance test (OGTT) experiments of 3 volunteers. Partial least square (PLS) calibration model is established between the signals at every source-detector separation and its corresponding blood glucose levels. The results shows that the correlation coefficient (R) between 1.32 mm to 1.88 mm is lowest and they can be used as reference for background correction. The signal of this special position is important for improving the accuracy of near-infrared non-invasive blood glucose measurement.

  4. Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative acute kidney injury.

    Science.gov (United States)

    Mita, Naoji; Kawahito, Shinji; Soga, Tomohiro; Takaishi, Kazumi; Kitahata, Hiroshi; Matsuhisa, Munehide; Shimada, Mitsuo; Kinoshita, Hiroyuki; Tsutsumi, Yasuo M; Tanaka, Katsuya

    2017-03-01

    The aim of the present study was to evaluate the usefulness of a closed-loop system (STG-55; Nikkiso, Tokyo, Japan), a type of artificial endocrine pancreas for the continuous monitoring and control of intraoperative blood glucose, for preventing postoperative acute kidney injury (AKI) in patients undergoing hepatectomy. Thirty-eight patients were enrolled in this study. Glucose concentrations were controlled with either a manual injection of insulin based on a commonly used sliding scale (manual insulin group, n = 19) or the programmed infusion of insulin determined by the control algorithm of the artificial endocrine pancreas (programmed insulin group, n = 19). After the induction of anesthesia, a 20-G intravenous catheter was inserted into the peripheral forearm vein of patients in the programmed insulin group and connected to an artificial endocrine pancreas (STG-55). The target range for glucose concentrations was set to 100-150 mg/dL. The mean serum creatinine concentrations of preoperative, postoperative 24 and 48 h were 0.72, 0.78, and 0.79 mg/dL in the programmed insulin group, and 0.81, 0.95, and 1.03 mg/dL in the manual insulin group, respectively. Elevations in serum creatinine concentrations postoperative 48 h were significantly suppressed in the programmed insulin group. The STG-55 closed-loop system was effective for maintaining strict blood glucose control during hepatectomy with minimal variability in blood glucose concentrations and for suppressing elevations in serum creatinine concentrations. Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative AKI.

  5. Review of Blood Glucose Detective Methods%血糖检测方法的研究现状

    Institute of Scientific and Technical Information of China (English)

    王阳; 张松; 杨琳

    2011-01-01

    The control of the blood glucose is an important way for understanding pathogenic condition and evaluating treatment effects of mellitus diabetes. In this paper, the invasive, minimally invasive and non-invasive blood glucose detecting techniques in clinic are summarized respectively. Advantages and disadvantages of these techniques are compared and analyzed from the technical aspect. The technical principles of the current blood glucose monitoring instruments are analyzed. Non-invasive detection methods and their development foreground are specially introduced. Although there are many types of non-invasive blood glucose detectors, there is a lack of a non-invasive, continuous, dynamic, accurate, good- repeatability product, which can be widely used in home health care, and replace the traditional invasive blood glucose detector. At present, every one of the invasive, minimally invasive or non-invasive blood glucose detecting technique has its characteristic, can not be substituted each other. The non-invasive technique is the future of blood glucose detector, which still needs studied in a multi-interdisciplinary subject.%掌握血糖的变化是了解糖尿病病情和评价治疗效果的重要途径.本文从有创、微创和无创三个方面对血糖检测方法及存在问题进行了陈述;从技术方面对目前的血糖仪进行分析,着重介绍了无创检测方式的原理及发展前景.虽然无创血糖检测方法很多,但目前仍然缺乏一种无创伤、连续、动态、准确、重复性良好的方法,使之能够广泛应用于家庭保健,并取代传统的有创血糖检测仪.有创、微创、无创血糖检测方法目前各有优劣,尚无法相互取代,而无创血糖检测是未来血糖检测技术发展的方向,有待于多学科的综合研究.

  6. Point-of-Care Glucose and Ketone Monitoring.

    Science.gov (United States)

    Chong, Siew Kim; Reineke, Erica L

    2016-03-01

    Early and rapid identification of hypo- and hyperglycemia as well as ketosis is essential for the practicing veterinarian as these conditions can be life threatening and require emergent treatment. Point-of-care testing for both glucose and ketone is available for clinical use and it is important for the veterinarian to understand the limitations and potential sources of error with these tests. This article discusses the devices used to monitor blood glucose including portable blood glucose meters, point-of-care blood gas analyzers and continuous glucose monitoring systems. Ketone monitoring options discussed include the nitroprusside reagent test strips and the 3-β-hydroxybutyrate ketone meter. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Additional benefit of higher dose green tea in lowering postprandial blood glucose

    Directory of Open Access Journals (Sweden)

    Rita Lahirin

    2015-07-01

    Full Text Available Background: Green tea contains catechins that have inhibitory effects on amylase, sucrase, and sodium-dependent glucose transporter (SGLT which result in lowering of postprandial blood glucose (PBG. This beneficial effect has been widely demonstrated using the usual dose (UD of green tea preparation. Our study was aimed to explore futher lowering of PBG using high dose (HD of green tea in healthy adolescents.Methods: 24 subjects received 100 mL infusion of either 0.67 or 3.33 grams of green tea with test meal. Fasting, PBG at 30, 60, 120 minutes were measured. Subjects were cross-overed after wash out. PBG and its incremental area under the curve (IAUC difference between groups were analyzed with paired T-test. Cathecin contents of tea were measured using high-performance liquid chromatography (HPLC.Results: The PBG of HD group was lower compared to UD (at 60 minutes =113.70 ± 13.20 vs 124.16 ± 8.17 mg/dL, p = 0.005; at 120 minutes = 88.95 ± 6.13 vs 105.25 ± 13.85 mg/dL, p < 0.001. The IAUC of HD was also found to be lower compared to UD (2055.0 vs 3411.9 min.mg/dL, p < 0.001.Conclusion: Additional benefit of lowering PBG can be achieved by using higher dose of green tea. This study recommends preparing higher dose of green tea drinks for better control of PBG.

  8. Welltang - A smart phone-based diabetes management application - Improves blood glucose control in Chinese people with diabetes.

    Science.gov (United States)

    Zhou, Weibin; Chen, Min; Yuan, Jingyun; Sun, Yan

    2016-06-01

    The primary objective was to evaluate the impact of the smart phone-based diabetes management application, Welltang, on glycated hemoglobin (HbA1c). The second objective was to measure whether Welltang improves blood glucose, low-density lipoprotein cholesterol, weight, blood pressure, hypoglycemic events, satisfaction of patients to use Welltang, diabetes knowledge of patients, and self-care behaviors. One hundred evenly randomized subjects with diabetes, aged 18-74years, were recruited from the outpatient Department of Endocrinology for a 3-month study. The Welltang intervention group received training for the use of Welltang, while the control group received their usual standard of care. HbA1c, blood glucose, low-density lipoprotein cholesterol, weight, blood pressure, hypoglycemic events, satisfaction of patients to use Welltang, diabetes knowledge of patients, and self-care behaviors were measured. Patient data were analyzed using independent t test and paired sample test using SPSS version 12. The average decrease in HbA1c was 1.95% (21mmol/mol) in the intervention group and 0.79% (8mmol/mol) in the control group (P<0.001). Measures of self-monitored blood glucose, diabetes knowledge, and self-care behaviors improved in patients in the intervention group. Eighty four percent of patients in the intervention group were satisfied with the use of Welltang. Differences in hypoglycemic events, low-density lipoprotein cholesterol, weight, and blood pressure were not statistically significant. Diabetes patients using the Welltang application achieved statistically significant improvements in HbA1c, blood glucose, satisfaction of patients to use of Welltang, diabetes knowledge, and self-care behaviors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. In vivo measurements of brain glucose transport using the reversible Michaelis-Menten model and simultaneous measurements of cerebral blood flow changes during hypoglycemia.

    Science.gov (United States)

    Choi, I Y; Lee, S P; Kim, S G; Gruetter, R

    2001-06-01

    Glucose is the major substrate that sustains normal brain function. When the brain glucose concentration approaches zero, glucose transport across the blood-brain barrier becomes rate limiting for metabolism during, for example, increased metabolic activity and hypoglycemia. Steady-state brain glucose concentrations in alpha-chloralose anesthetized rats were measured noninvasively as a function of plasma glucose. The relation between brain and plasma glucose was linear at 4.5 to 30 mmol/L plasma glucose, which is consistent with the reversible Michaelis-Menten model. When the model was fitted to the brain glucose measurements, the apparent Michaelis-Menten constant, Kt, was 3.3 +/- 1.0 mmol/L, and the ratio of the maximal transport rate relative to CMRglc, Tmax/CMRglc, was 2.7 +/- 0.1. This Kt is comparable to the authors' previous human data,