WorldWideScience

Sample records for blood glucose control

  1. Why control blood glucose levels?

    Science.gov (United States)

    Rossini, A A

    1976-03-01

    The controversy as to the relationship between the degree of control of diabetes and the progression of the complications of the disease has not been solved. However, in this review, various studies suggesting a relationship between the metabolic abnormality and the diabetic complications are examined. The disadvantages of the uncontrolled diabetes mellitus can be divided into two major categories-short-term and long-term. The short-term disadvantages of controlled diabetes mellitus include the following: (1) ketoacidosis and hyperosmolar coma; (2) intracellular dehydration; (3) electrolyte imbalance; (4) decreased phagocytosis; (5) immunologic and lymphocyte activity; (6) impairment of wound healing; and (7) abnormality of lipids. The long-term disadvantages of uncontrolled diabetes melitus include the following: (1) nephropathy; (2) neuropathy; (3) retinopathy; (4) cataract formation; (5) effect on perinatal mortality; (6) complications of vascular disease; and (7) the evaluation of various clinical studies suggesting the relationship of elevated blood glucose levels and complications of diabetes mellitus. It is suggested that until the question of control can absolutely be resolved, the recommendation is that the blood glucose levels should be controlled as close to the normal as possible.

  2. Ex vivo changes in blood glucose levels seldom change blood glucose control algorithm recommendations

    NARCIS (Netherlands)

    de Groene, L.; Harmsen, R. E.; Binnekade, J. M.; Spronk, P. E.; Schultz, M. J.

    2010-01-01

    Background. Hyperglycemia and glycemic variabilities are associated with adverse outcomes in critically ill patients. Blood glucose control with insulin mandates an adequate and precise assessment of blood glucose levels. Blood glucose levels, however, can change ex vivo after sampling. The aim of

  3. Blood glucose control and monitoring in the critically ill

    NARCIS (Netherlands)

    van Hooijdonk, R.T.M.

    2015-01-01

    This thesis deals with blood glucose control and blood glucose monitoring in intensive care unit (ICU) patients: two important aspects of care for and monitoring of critically ill patients. While the precise targets of blood glucose control in ICU patients remain a matter of debate, currently many,

  4. Inhaled insulin for controlling blood glucose in patients with diabetes

    Directory of Open Access Journals (Sweden)

    Bernard L Silverman

    2008-01-01

    Full Text Available Bernard L Silverman1, Christopher J Barnes2, Barbara N Campaigne3, Douglas B Muchmore31Alkermes, Inc, Cambridge, MA, USA; 2i3 Statprobe, Ann Arbor, MI; 3Eli Lilly and Company, Indianapolis, IN, USAAbstract: Diabetes mellitus is a significant worldwide health problem, with the incidence of type 2 diabetes increasing at alarming rates. Insulin resistance and dysregulated blood glucose control are established risk factors for microvascular complications and cardiovascular disease. Despite the recognition of diabetes as a major health issue and the availability of a growing number of medications designed to counteract its detrimental effects, real and perceived barriers remain that prevent patients from achieving optimal blood glucose control. The development and utilization of inhaled insulin as a novel insulin delivery system may positively influence patient treatment adherence and optimal glycemic control, potentially leading to a reduction in cardiovascular complications in patients with diabetes.Keywords: diabetes, inhaled insulin, cardiovascular disease, blood glucose

  5. Discrete Blood Glucose Control in Diabetic Göttingen Minipigs

    Directory of Open Access Journals (Sweden)

    Berno J.E. Misgeld

    2016-07-01

    Full Text Available Despite continuous research effort, patients with type 1 diabetes mellitus (T1D experience difficulties in daily adjustments of their blood glucose concentrations. New technological developments in the form of implanted intravenous infusion pumps and continuous blood glucose sensors might alleviate obstacles for the automatic adjustment of blood glucose concentration. These obstacles consist, for example, of large time-delays and insulin storage effects for the subcutaneous/interstitial route. Towards the goal of an artificial pancreas, we present a novel feedback controller approach that combines classical loop-shaping techniques with gain-scheduling and modern H ∞ -robust control approaches. A disturbance rejection design is proposed in discrete frequency domain based on the detailed model of the diabetic Göttingen minipig. The model is trimmed and linearised over a large operating range of blood glucose concentrations and insulin sensitivity values. Controller parameters are determined for each of these operating points. A discrete H ∞ loop-shaping compensator is designed to increase robustness of the artificial pancreas against general coprime factor uncertainty. The gain scheduled controller uses subcutaneous insulin injection as a control input and determines the controller input error from intravenous blood glucose concentration measurements, where parameter scheduling is achieved by an estimator of the insulin sensitivity parameter. Thus, only one controller stabilises a family of animal models. The controller is validated in silico with a total number of five Göttingen Minipig models, which were previously obtained by experimental identification procedures. Its performance is compared with an experimentally tested switching PI-controller.

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  7. Simultaneous control of blood glucose, blood pressure, and lipid ...

    African Journals Online (AJOL)

    2016-01-21

    Jan 21, 2016 ... A questionnaire was used to collect basic information and blood samples were drawn for laboratory measurements. Simultaneous control was defined as HbA1c <7%, BP <130/80 mmHg, and LDL‑C <2.6 mmol/L. Results: A total of 2274 individuals were included, of which 588 individuals (25.9%) achieved ...

  8. [Blood glucose self monitoring].

    Science.gov (United States)

    Wascher, Thomas C; Stechemesser, Lars

    2016-04-01

    Self monitoring of blood glucose contributes to the integrated management of diabetes mellitus. It, thus, should be available for all patients with diabetes mellitus type-1 and type-2. Self monitoring of blood glucose improves patients safety, quality of life and glucose control. The current article represents the recommendations of the Austrian Diabetes Association for the use of blood glucose self monitoring according to current scientific evidence.

  9. Overnight Control of Blood Glucose in People with Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe

    2012-01-01

    In this paper, we develop and test a Model Predictive Controller (MPC) for overnight stabilization of blood glucose in people with type 1 diabetes. The controller uses glucose measurements from a continuous glucose monitor (CGM) and its decisions are implemented by a continuous subcutaneous insulin...

  10. Performance Analysis of Fuzzy-PID Controller for Blood Glucose Regulation in Type-1 Diabetic Patients.

    Science.gov (United States)

    Yadav, Jyoti; Rani, Asha; Singh, Vijander

    2016-12-01

    This paper presents Fuzzy-PID (FPID) control scheme for a blood glucose control of type 1 diabetic subjects. A new metaheuristic Cuckoo Search Algorithm (CSA) is utilized to optimize the gains of FPID controller. CSA provides fast convergence and is capable of handling global optimization of continuous nonlinear systems. The proposed controller is an amalgamation of fuzzy logic and optimization which may provide an efficient solution for complex problems like blood glucose control. The task is to maintain normal glucose levels in the shortest possible time with minimum insulin dose. The glucose control is achieved by tuning the PID (Proportional Integral Derivative) and FPID controller with the help of Genetic Algorithm and CSA for comparative analysis. The designed controllers are tested on Bergman minimal model to control the blood glucose level in the facets of parameter uncertainties, meal disturbances and sensor noise. The results reveal that the performance of CSA-FPID controller is superior as compared to other designed controllers.

  11. Trends in practice of blood glucose control in critically ill patients in the Netherlands

    NARCIS (Netherlands)

    van Hooijdonk, R. T. M.; Eslami, S.; de Keizer, N. F.; Bakhshi-Raiez, F.; Bosman, R. J.; Dongelmans, D. A.; van der Voort, P. H. J.; Streefkerk, J. O.; Engelbrecht, W. J.; ten Cate, J.; Huissoon, S.; van Driel, E. M.; van Dijk, I.; Cimic, N.; Beck, O. F. T.; Snellen, F. T. F.; Holman, N. D.; Mulder, H. C.; Abu-Hanna, A.; Schultz, M. J.

    2015-01-01

    Publication of the Normoglycemia in Intensive Care Evaluation and Survival Using Glucose Algorithm Regulation (NICE-SUGAR) trial in 2009 and several observational studies caused a change in the recommendations for blood glucose control in intensive care patients. We evaluated local trends in blood

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... We Are Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... Type 2 Diabetes program to get help and support during your first year. Featured Book Type 2 ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  16. Glycolysis in the control of blood glucose homeostasis

    OpenAIRE

    Xin Guo; Honggui Li; Hang Xu; Shihlung Woo; Hui Dong; Fuer Lu; Alex J. Lange; Chaodong Wu

    2012-01-01

    Glycolysis, a simple pathway of glucose metabolism, critically regulates insulin secretion and metabolic functions of various cells. Depending on cell types, rates of glycolysis are determined at various steps of glycolysis that are subjected to the control of key metabolic and regulatory enzyme(s), which include glucokinase, 6-phosphofructo-1-kinase, and 6-phosphofructo-2-kinase/fructose-2,6-bisphosphatase. These enzymes are regulated by both nutritional and hormonal signals at the levels of...

  17. Glycolysis in the control of blood glucose homeostasis

    Directory of Open Access Journals (Sweden)

    Xin Guo

    2012-08-01

    Full Text Available Glycolysis, a simple pathway of glucose metabolism, critically regulates insulin secretion and metabolic functions of various cells. Depending on cell types, rates of glycolysis are determined at various steps of glycolysis that are subjected to the control of key metabolic and regulatory enzyme(s, which include glucokinase, 6-phosphofructo-1-kinase, and 6-phosphofructo-2-kinase/fructose-2,6-bisphosphatase. These enzymes are regulated by both nutritional and hormonal signals at the levels of transcription, translation, and post-translational modifications. In hepatocytes, glycolysis is involved in the control of hepatic glucose production. The latter, when excessive, contributes to hyperglycemia in diabetes. In pancreatic β cells, glycolysis couples glucose-stimulated insulin secretion. Absolute or relatively low levels of circulating insulin causes hyperglycemia. In adipocytes, glycolysis generates metabolites for lipogenesis and channels fatty acids from excessive oxidation to triglyceride synthesis, thereby reducing oxidative stress. With increased proinflammatory status, adipocytes produce pro-hyperglycemic factors and bring about hyperglycemia and insulin resistance. In hypothalamic neurons, glycolysis conveys nutrient sensing that is related to feeding control. Dysregulation of glycolysis occurs in conditions of insulin deficiency or resistance, and is attributable to inappropriate amount and/or activities of metabolic and regulatory enzymes of glycolysis. Targeting key metabolic and regulatory enzymes to enhance glycolysis may offer viable approaches for treatment of diabetes.

  18. Control of Blood Glucose for People with Type 1 Diabetes: an in Vivo Study

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Schmidt, Signe; Duun-Henriksen, Anne Katrine

    2012-01-01

    Since continuous glucose monitoring (CGM) technology and insulin pumps have improved recent years, a strong interest in a closed-loop articial pancreas for people with type 1 diabetes has arisen. Presently, a fully automated controller of blood glucose must face many challenges, such as daily...... variations of patient's physiology and lack of accuracy of glucose sensors. In this paper we design and discuss an algorithm for overnight closed-loop control of blood glucose in people with type 1 diabetes. The algorithm is based on Model Predictive Control (MPC). We use an oset-free autoregressive model...... during daytime. These trials demonstrate the importance of observer design in ARMAX models and show the possibility of stabilizing blood glucose during the night....

  19. Blood Test: Glucose

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Glucose KidsHealth / For Parents / Blood Test: Glucose What's ... español Análisis de sangre: glucosa What Is a Blood Test? A blood test is when a sample of ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page ... and-how-tos, . In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood ...

  1. Blood glucose control in the intensive care unit: benefits and risks.

    Science.gov (United States)

    Gunst, Jan; Van den Berghe, Greet

    2010-01-01

    Abnormal blood glucose levels are common during critical illness and are associated with outcomes that correspond to a J-shaped curve, the lowest risk associated with normoglycemia. Three proof-of-concept randomized-controlled-trials performed in the surgical, medical, and pediatric intensive care units of the Leuven University Hospital in Belgium demonstrated that maintaining strict age-adjusted normal fasting levels of glycemia (80-110 mg/dl in adults, 70-100 mg/dl in children, 50-80 mg/dl in infants) with intensive insulin therapy reduced morbidity and mortality as compared with tolerating stress hyperglycemia as a potentially beneficial response. Recently, concern has risen about the safety of this intervention, as a multicenter adult study reported an, as yet unexplained, increased mortality with targeting normoglycemia as compared with an intermediate blood glucose level of around 140 mg/dl. This apparent contradiction may be explained by several methodological differences among studies, comprising, among others, different glucose target ranges in the control groups, different feeding policies, and variable accuracy of tools used for glucose measurement and insulin infusion. Hence, efficacy and safety of intensive insulin therapy may be affected by patient-related and ICU setting-related variables. Therefore, no single optimal blood glucose target range for ICU patients can be advocated. It appears safe not to embark on targeting "age-normal" levels in intensive care units (ICUs) that are not equipped to accurately and frequently measure blood glucose, and have not acquired extensive experience with intravenous insulin administration using a customized guideline. A simple fallback position could be to control blood glucose levels as close to normal as possible without evoking unacceptable blood glucose fluctuations, hypoglycemia, and hypokalemia.

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  4. Current concepts in blood glucose monitoring

    OpenAIRE

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on t...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... your blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. ... to detect hyperglycemia so you can treat it early — before it gets worse. If you're new ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Day in the Life of Diabetes Famous People Working to Stop Diabetes Common Terms Diabetes Statistics Infographics ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Started Safely Get And Stay Fit Types of Activity Weight Loss Assess Your Lifestyle Getting Started Food ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ... Find Your Local Office Find your local diabetes education program Calendar of Events Wellness Lives Here Awareness ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & ... cannot release all the ketones and they build up in your blood, which can lead to ketoacidosis. ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Clinical Practice Guidelines Patient Education Materials Scientific Sessions Journals for Professionals Professional Books Patient Access to Research ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Quick Meal Ideas Snacks Nutrient Content Claims Understanding Carbohydrates Types of Carbohydrates Carbohydrate Counting Make Your Carbs ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health ...

  20. Bihormonal control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tárnik, Marían; Murgaš, Ján

    2015-01-01

    This paper presents a bihormonal artificial pancreas (AP) for people with type 1 diabetes (T1D) designed to provide a safe blood glucose control with minimal use of glucagon. The control algorithm uses insulin as well as glucagon to prevent hyper- and hypoglycemia. We employ a novel prediction...

  1. Bihormonal model predictive control of blood glucose in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Batora, Vladimir; Tarnik, Marian; Murgas, Jan

    2014-01-01

    In this paper we present a bihormonal control system that controls blood glucose in people with type 1 diabetes (T1D). We use insulin together with glucagon to mitigate the negative effects of hyper- and hypoglycemia. The system consists of a Kalman filter, a micro-bolus insulin and glucagon...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And Stay Fit Types ... the following: High blood glucose High levels of sugar in the ... Part of managing your diabetes is checking your blood glucose often. Ask your ...

  3. Treatment and blood glucose level control of diabetes patients aged 30 and above in Balcova

    Directory of Open Access Journals (Sweden)

    Kevser Tarı Selçuk

    2015-04-01

    Full Text Available AbstractObjective: This cross-sectional study aims to evaluate the treatment uptake and control rates of blood glucose, BMI, blood pressure, lipid levels in diabetes patients aged 30 and above in Balcova Heart Study. The association between treatment and blood glucose level control and socio-demographic characteristics will also be evaluated. Methods: The study included data from 1.643 diabetes patients aged 30 and above who participated in the baseline survey of Balcova’s Heart Project. Fasting blood glucose test was carried out for diagnosis of diabetes, and ADA 2011 diagnosis criteria were employed for the overall assessment. Descriptive statistics, chi-square, logistic regression analysis were used. The study was supported by Dokuz Eylul University Scientific Research Projects and Balcova Municipality. Results: Of all patients, 75.4% are receiving treatment, 32.6% of treated patients have blood glucose level, 21.8% have blood pressure, 9.4% have BMI, 34.7% have LDL, 45.2% have HDL, and 52.6% have triglyceride levels under control. According to logistic regression model, diabetes treatment is significantly high for 70 and above age group [OR=1.76, %95.0 CI:1.14-2.72]; for patients with social security[OR=2.21, %95.0 CI:1.39-3.52]; and for patients with coexisting chronic diseases[OR=2.24, %95.0 CI:1.74-2.89]. According to logistic regression model, blood glucose level control of treated patients is significantly high for patients with coexisting chronic diseases [OR=1.49, %95.0 GA:1.12-1.99]. Conclusions: One fourth of diabetes patients are not receiving treatment, and only one third of patients have blood glucose level under control. BMI, blood pressure, lipid control rates are below desired levels. Awareness of diabetes patient on importance of continuous follow-up should be raised, and quality follow-up should be improved.Key Words: Diabetes, diabetes treatment, blood glucose level

  4. Control of blood glucose in type 2 diabetes without weight loss by modification of diet composition

    Directory of Open Access Journals (Sweden)

    Gannon Mary C

    2006-03-01

    Full Text Available Abstract Background Over the past several years our research group has taken a systematic, comprehensive approach to determining the effects on body function (hormonal and non-hormonal of varying the amounts and types of proteins, carbohydrates and fats in the diet. We have been particularly interested in the dietary management of type 2 diabetes. Our objective has been to develop a diet for people with type 2 diabetes that does not require weight loss, oral agents, or insulin, but that still controls the blood glucose concentration. Our overall goal is to enable the person with type 2 diabetes to control their blood glucose by adjustment in the composition rather than the amount of food in their diet. Methods This paper is a brief summary and review of our recent diet-related research, and the rationale used in the development of diets that potentially are useful in the treatment of diabetes. Results We determined that, of the carbohydrates present in the diet, absorbed glucose is largely responsible for the food-induced increase in blood glucose concentration. We also determined that dietary protein increases insulin secretion and lowers blood glucose. Fat does not significantly affect blood glucose, but can affect insulin secretion and modify the absorption of carbohydrates. Based on these data, we tested the efficacy of diets with various protein:carbohydrate:fat ratios for 5 weeks on blood glucose control in people with untreated type 2 diabetes. The results were compared to those obtained in the same subjects after 5 weeks on a control diet with a protein:carbohydrate:fat ratio of 15:55:30. A 30:40:30 ratio diet resulted in a moderate but significant decrease in 24-hour integrated glucose area and % total glycohemoglobin (%tGHb. A 30:20:50 ratio diet resulted in a 38% decrease in 24-hour glucose area, a reduction in fasting glucose to near normal and a decrease in %tGHb from 9.8% to 7.6%. The response to a 30:30:40 ratio diet was similar

  5. Blood Glucose Determination

    DEFF Research Database (Denmark)

    Lippi, Giuseppe; Nybo, Mads; Cadamuro, Janne

    2018-01-01

    The measurement of fasting plasma glucose may be biased by a time-dependent decrease of glucose in blood tubes, mainly attributable to blood cell metabolism when glycolysis is not rapidly inhibited or blood cells cannot be rapidly separated from plasma. Although glycolysis inhibitors such as sodium...... fluoride (NaF) in combination with potassium oxalate (KOx) are currently used for overcoming this drawback, their efficacy for stabilizing blood glucose is seemingly limited, and probably lower than that of newer additives such as the citrate buffer. Therefore, we performed a critical analysis...

  6. Effects of self-monitoring of blood glucose on diabetes control in a ...

    African Journals Online (AJOL)

    Background: Diabetes mellitus places an enormous burden upon both patients and countries' health systems. Integral to achieving control is patients assuming responsibility for their condition. Self-monitoring of blood glucose (SMBG) can serve as a powerful tool modifying lifestyle behaviour and can aid in achieving ...

  7. Evaluation of a novel artificial pancreas: closed loop glycemic control system with continuous blood glucose monitoring.

    Science.gov (United States)

    Tsukamoto, Yuuki; Kinoshita, Yoshihiko; Kitagawa, Hiroyuki; Munekage, Masaya; Munekage, Eri; Takezaki, Yuka; Yatabe, Tomoaki; Yamashita, Koichi; Yamazaki, Rie; Okabayashi, Takehiro; Tarumi, Masatoshi; Kobayashi, Masaki; Mishina, Suguru; Hanazaki, Kazuhiro

    2013-04-01

    A closed-loop glycemic control system using an artificial pancreas has been applied with many clinical benefits in Japan since 1987. To update this system incorporating user-friendly features, we developed a novel artificial pancreas (STG-55). The purpose of this study was to evaluate STG-55 for device usability, performance of blood glucose measurement, glycemic control characteristics in vivo in animal experiments, and evaluate its clinical feasibility. There are several features for usability improvement based on the design concepts, such as compactness, display monitor, batteries, guidance function, and reduction of the preparation time. All animal study data were compared with a clinically available artificial pancreas system in Japan (control device: STG-22). We examined correlations of both blood glucose levels between two groups (STG-55 vs. control) using Clarke's error grid analysis, and also compared mean glucose infusion rate (GIR) during glucose clamp. The results showed strong correlation in blood glucose concentrations (Pearson's product-moment correlation coefficient: 0.97; n = 1636). Clarke's error grid analysis showed that 98.4% of the data fell in Zones A and B, which represent clinically accurate or benign errors, respectively. The difference in mean GIRs was less than 0.2 mg/kg/min, which was considered not significant. Clinical feasibility study demonstrated sufficient glycemic control maintaining target glucose range between 80 and 110 (mg/dL), and between 140 and 160 without any hypoglycemia. In conclusion, STG-55 was a clinically acceptable artificial pancreas with improved interface and usability. A closed-loop glycemic control system with STG-55 would be a useful tool for surgical and critical patients in intensive care units, as well as diabetic patients. © 2013, Copyright the Authors. Artificial Organs © 2013, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Current concepts in blood glucose monitoring.

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-12-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  9. Current concepts in blood glucose monitoring

    Directory of Open Access Journals (Sweden)

    Kranti Shreesh Khadilkar

    2013-01-01

    Full Text Available Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG and continuous glucose monitoring system (CGMS. It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... Find Your Local Office Find your local diabetes education program Calendar of Events Wellness Lives Here Awareness ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Student Resources History of Diabetes Resources for School Projects How to Reference Our Site Diabetes Basics Myths ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health Insurance Health Insurance Update The Health Insurance ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Us in the Fight for a Cure Your tax-deductible gift today can fund critical diabetes research ... may make your blood glucose level go even higher. You'll need to work with your doctor ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C ... your doctor may change the amount of your medication or insulin or possibly the timing of when ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 About Us Online Community Meal Planning Sign In Search: Search More Sites Search ≡ Are You ... m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Honorees How We Fund Research Funding the Next Generation of Brilliant Researchers Diabetes Pro: Professional Resources Online ... blood glucose level go even higher. You'll need to work with your doctor to find the ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... someone new is diagnosed. Diabetes causes more deaths a year than breast cancer and AIDS combined. Your gift today will help ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 ... blood glucose level go even higher. You'll need to work with your doctor to find the ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the urine Frequent urination Increased thirst Part of managing your diabetes is checking your blood glucose often. ... also help. Work with your dietitian to make changes in your meal plan. If exercise and changes ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... such as family conflicts or school or dating problems. You may have experienced the dawn phenomenon (a ... high blood glucose early will help you avoid problems associated with hyperglycemia. How Do I Treat Hyperglycemia? ...

  3. Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database

    Science.gov (United States)

    Evans, Josie M M; Newton, Ray W; Ruta, Danny A; MacDonald, Thomas M; Stevenson, Richard J; Morris, Andrew D

    1999-01-01

    Objectives To investigate patterns of self monitoring of blood glucose concentration in diabetic patients who use insulin and to determine whether frequency of self monitoring is related to glycaemic control. Setting Diabetes database, Tayside, Scotland. Subjects Patients resident in Tayside in 1993-5 who were using insulin and were registered on the database and diagnosed with insulin dependent (type 1) or non-insulin dependent (type 2) diabetes before 1993. Main outcome measures Number of glucose monitoring reagent strips dispensed (reagent strip uptake) derived from records of prescriptions. First recorded haemoglobin A1c concentration in the study period, and reagent strips dispensed in the previous 6 months. Results Among 807 patients with type 1 diabetes, 128 (16%) did not redeem any prescriptions for glucose monitoring reagent strips in the 3 year study period. Only 161 (20%) redeemed prescriptions for enough reagent strips to test glucose daily. The corresponding figures for the 790 patients with type 2 diabetes who used insulin were 162 (21%; no strips) and 131 (17%; daily tests). Reagent strip uptake was influenced both by age and by deprivation category. There was a direct relation between uptake and glycaemic control for 258 patients (with recorded haemoglobin A1c concentrations) with type 1 diabetes. In a linear regression model the decrease in haemoglobin A1c concentration for every extra 180 reagent strips dispensed was 0.7%. For the 290 patients with type 2 diabetes who used insulin there was no such relation. Conclusions Self monitoring of blood glucose concentration is associated with improved glycaemic control in patients with type 1 diabetes. Regular self monitoring in patients with type 1 and type 2 diabetes is uncommon. Key messagesSeveral studies have indicated the importance of self monitoring of blood glucose concentration for prevention of complications in patients with diabetesUptake of reagent strips for self monitoring of blood glucose

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Research & Practice Ways to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know ... We Support Your Doctor Clinical Practice Guidelines Patient Education Materials Scientific ... for School Projects How to Reference Our Site Diabetes Basics ...

  8. [Effects of blood glucose control on glucose variability and clinical outcomes in patients with severe acute pancreatitis in intensive care unit].

    Science.gov (United States)

    Wu, Jing; Sun, Qiuhong; Yang, Hua

    2015-05-19

    To explore the effects of blood glucose control on glucose variability and clinical outcomes in patients with severe acute pancreatitis in intensive care unit (ICU). A total of 72 ICU patients with severe acute pancreatitis were recruited and divided randomly into observation and control groups (n = 36 each). Both groups were treated conventionally. And the observation group achieved stable blood glucose at 6.1-8.3 mmol/L with intensive glucose control. The length of ICU and hospital stays, ICU mortality rate, transit operative rate, concurrent infection rate, admission blood glucose, glycosylated hemoglobin, mean insulin dose, mean blood glucose, blood glucose value standard deviation (GLUSD), glycemic liability index (GLUGLI) and mean amplitude of glycemic excursion (GLUMAGE) of two groups were compared. At the same time, the relationship between blood glucose variability, ICU mortality rate and its predictive value were analyzed by correlation analysis and receiver operating characteristic curve (ROC). The lengths of ICU and hospital stays of observation group were all significantly less than those of the control group [(11.7 ± 9.9) vs (15.9 ± 8.02) days, (21.8 ± 10.8) vs (28.2 ± 12.7) days, P control group (72.22%, 38.89%, P blood glucose value and GLUSD of observation group were significantly lower than those of control group [(7.4 ± 1.1) vs (9.6 ± 1.2), (1.8 ± 1.0) vs (2.5 ± 1.3) mmol/L]. The differences were statistically significant (P control group (P control in patients with severe acute pancreatitis helps reduce the blood sugar fluctuations, lower the risks of infectious complications and promote the patient rehabilitation. And GLUGLI is positively correlated with ICU mortality rate. It has good predictive values.

  9. Garlic intake lowers fasting blood glucose: meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Hou, Li-qiong; Liu, Yun-hui; Zhang, Yi-yi

    2015-01-01

    Garlic is a common spicy flavouring agent also used for certain therapeutic purposes. Garlic's effects on blood glucose have been the subject of many clinical and animal studies, however, studies reporting hypoglycemic effects of garlic in humans are conflicting. A comprehensive literature search was conducted to identify relevant trials of garlic or garlic extracts on markers of glycemic control [fasting blood glucose (FBG), postprandial glucose (PPG), glycosylated haemoglobin (HbA1c)]. A meta-analysis of the effect of garlic intake on human was done to assess garlic's effectiveness in lowering glucose levels. Two reviewers extracted data from each of the identified studies. Seven eligible randomized controlled trials with 513 subjects were identified. Pooled analyses showed that garlic intake results in a statistically significant lowering in FBG [SMD=-1.67; 95% CI (-2.80, -0.55), p=0.004]. Our pooled analyses did not include PPG control and HbA1c outcomes. Because only 1 study included in the meta-analysis reported PPG variables and only 2 studies reported HbA1c variables. In conclusion, the current meta-analysis showed that the administration of garlic resulted in a significant reduction in FBG concentrations. More trials are needed to investigate the effectiveness of garlic on HbA1c and PPG.

  10. Blood glucose in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj

    2009-01-01

    Blood glucose is often elevated in acute stroke, and higher admission glucose levels are associated with larger lesions, greater mortality and poorer functional outcome. In patients treated with thrombolysis, hyperglycemia is associated with an increased risk of hemorrhagic transformation...... of infarcts. For a number of years, tight glycemic control has been regarded as beneficial in critically illness, but recent research has been unable to support this notion. The only completed randomized study on glucose-lowering therapy in stroke has failed to demonstrate effect, and concerns relating...... to the risk of inducing potentially harmful hypoglycemia has been raised. Still, basic and observational research is overwhelmingly in support of a causal relationship between blood glucose and stroke outcome and further research on glucose-lowering therapy in acute stroke is highly warranted....

  11. Effects of intensive control of blood glucose and blood pressure on microvascular complications in patients with type II diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Ling Wang

    2013-04-01

    Full Text Available AIM:To evaluate the effects of intensive control of blood glucose and blood pressure on microvascular complications in patients with type II diabetes by comparing the therapeutic effects of intensive and standard treatment in patients with type II diabetes.METHODS: A total of 107 patients with type II diabetes were randomly assigned into intensive and standard treatment groups. Patients in the intensive treatment group received preterax (perindopril/ indapamide to control blood pressure, and gliclazide (diamicron MR to control blood glucose. Patients in the standard treatment group received routine medications or placebo. Urinary microalbumin (UMA, urinary creatinine (UCR, the UMA/UCR ratio, and visual acuity were monitored according to the study design of the ADVANCE trial. Direct ophthalmoscopy and seven-field stereoscopic retinal photography were used to examine the fundi at baseline, and repeated after 5 years of treatment.RESULTS: The characteristics of patients in both groups were well balanced at baseline. After 5 years of treatment, visual acuity was found to be decreased in the standard group (P=0.04, but remained stable in the intensive group. The severity of diabetic retinopathy had not progressed in patients in the intensive group, but had deteriorated in the standard group (P=0.0006. The UMA/UCR ratio was not obviously changed in patients in the intensive group, whereas it was significantly increased in the standard group (P=0.00.CONCLUSION: Intensive control of blood glucose and blood pressure can decrease the incidence or slow the progression of microvascular complications in patients with type II diabetes, and maintain stable vision.

  12. Correlation of salivary glucose, blood glucose and oral candidal carriage in the saliva of type 2 diabetics: A case-control study

    Directory of Open Access Journals (Sweden)

    Satish Kumar

    2014-01-01

    Full Text Available Objectives: To study the correlation between blood glucose levels and salivary glucose levels in type 2 diabetic patients, to study the relationship between salivary glucose levels and oral candidal carriage in type 2 diabetic patients and to determine whether salivary glucose levels could be used as a noninvasive tool for the measurement of glycemic control in type 2 diabetics. Study Design: The study population consisted of three groups: Group 1 consisted of 30 controlled diabetics and Group 2 consisted of 30 uncontrolled diabetics based on their random nonfasting plasma glucose levels. Group 3 consisted of 30 healthy controls. Two milliliters of peripheral blood was collected for the estimation of random nonfasting plasma glucose levels and glycosylated hemoglobin (HbA1c. Unstimulated saliva was collected for the estimation of salivary glucose. Saliva was collected by the oral rinse technique for the estimation of candidal counts. Results: The salivary glucose levels were significantly higher in controlled and uncontrolled diabetics when compared with controls. The salivary candidal carriage was also significantly higher in uncontrolled diabetics when compared with controlled diabetics and nondiabetic controls. The salivary glucose levels showed a significant correlation with blood glucose levels, suggesting that salivary glucose levels can be used as a monitoring tool for predicting glycemic control in diabetic patients. Conclusion: The present study found that estimation of salivary glucose levels can be used as a noninvasive, painless technique for the measurement of diabetic status of a patient in a dental set up. Increased salivary glucose levels leads to increased oral candidal carriage; therefore, oral diagnosticians are advised to screen the diabetic patients for any oral fungal infections and further management.

  13. Effects of high-bran bread on blood glucose control in insulin-dependent diabetic patients.

    Science.gov (United States)

    Nygren, C; Hallmans, G; Lithner, F

    1984-01-01

    The purpose of these studies was to determine whether rye bran, baked into crisp bread (high-bran bread), would affect the blood glucose levels and insulin requirements in insulin-dependent diabetic patients. The high-bran bread was compared with a low-bran bread (series I) and with the usual bread in the patients' diet (series II). The low-bran bread contained 5% dietary fiber, the high-bran bread 18% and the usual bread in the patient's diet 4% as a mean (enzymatic method). In series I five women consumed the low-bran bread for two weeks and then changed to the high-bran bread for four weeks. In series II two men and five women consumed their usual bread during a control period of two weeks and high-bran during the following two weeks. The insulin doses were reduced or the blood glucose concentrations were lowered during the high-bran bread periods.

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... Pinterest Youtube Instagram Diabetes Stops Here Blog Online Community Site ... Day Prediabetes My Health Advisor Tools to Know Your Risk Diabetes Basics ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Monthly In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online ... Print Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... around 4:00 a.m. to 5:00 a.m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... work with your doctor to find the safest way for you to lower your blood glucose level. Cutting down on the amount of food you eat might also help. Work with your dietitian to make changes in your meal plan. If exercise and changes ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... the safest way for you to lower your blood glucose level. Cutting down on the amount of food you eat might also help. Work with your dietitian to make changes in your meal plan. If exercise and changes in your diet ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  1. Optimal blood glucose control in diabetes mellitus treatment using dynamic programming based on Ackerman’s linear model

    Science.gov (United States)

    Pradanti, Paskalia; Hartono

    2018-03-01

    Determination of insulin injection dose in diabetes mellitus treatment can be considered as an optimal control problem. This article is aimed to simulate optimal blood glucose control for patient with diabetes mellitus. The blood glucose regulation of diabetic patient is represented by Ackerman’s Linear Model. This problem is then solved using dynamic programming method. The desired blood glucose level is obtained by minimizing the performance index in Lagrange form. The results show that dynamic programming based on Ackerman’s Linear Model is quite good to solve the problem.

  2. "Learning" Can Improve the Blood Glucose Control Performance for Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Wang, Youqing; Zhang, Jinping; Zeng, Fanmao; Wang, Na; Chen, Xiaoping; Zhang, Bo; Zhao, Dong; Yang, Wenying; Cobelli, Claudio

    2017-01-01

    A learning-type artificial pancreas has been proposed to exploit the repetitive nature in the blood glucose dynamics. We clinically evaluated the efficacy of the learning-type artificial pancreas. We conducted a pilot clinical study in 10 participants of mean age 36.1 years (standard deviation [SD] 12.7; range 16-58) with type 1 diabetes. Each trial was conducted for eight consecutive mornings. The first two mornings were open-loop to obtain the individualized parameters. Then, the following six mornings were closed-loop, during which a learning-type model predictive control algorithm was employed to calculate the insulin infusion rate. To evaluate the algorithm's robustness, each participant took exercise or consumed alcohol on the fourth or sixth closed-loop day and the order was determined randomly. The primary outcome was the percentage of time spent in the target glucose range of 3.9-8.0 mmol/L between 0900 and 1200 h. The percentage of time with glucose spent in target range was significantly improved from 51.6% on day 1 to 71.6% on day 3 (mean difference between groups 17.9%, confidence interval [95% CI] 3.6-32.1; P = 0.020). There were no hypoglycemic episodes developed on day 3 compared with two episodes on day 1. There was no difference in the percentage of time with glucose spent in target range between exercise day versus day 5 and alcohol day versus day 5. The learning-type artificial pancreas system achieved good glycemic regulation and provided increased effectiveness over time. It showed a satisfactory performance even when the blood glucose was challenged by exercise or alcohol.

  3. Diabetes Technology: Markers, Monitoring, Assessment, and Control of Blood Glucose Fluctuations in Diabetes

    Directory of Open Access Journals (Sweden)

    Boris P. Kovatchev

    2012-01-01

    Full Text Available People with diabetes face a life-long optimization problem: to maintain strict glycemic control without increasing their risk for hypoglycemia. Since the discovery of insulin in 1921, the external regulation of diabetes by engineering means has became a hallmark of this optimization. Diabetes technology has progressed remarkably over the past 50 years—a progress that includes the development of markers for diabetes control, sophisticated monitoring techniques, mathematical models, assessment procedures, and control algorithms. Continuous glucose monitoring (CGM was introduced in 1999 and has evolved from means for retroactive review of blood glucose profiles to versatile reliable devices, which monitor the course of glucose fluctuations in real time and provide interactive feedback to the patient. Technology integrating CGM with insulin pumps is now available, opening the field for automated closed-loop control, known as the artificial pancreas. Following a number of in-clinic trials, the quest for a wearable ambulatory artificial pancreas is under way, with a first prototype tested in outpatient setting during the past year. This paper discusses key milestones of diabetes technology development, focusing on the progress in the past 10 years and on the artificial pancreas—still not a cure, but arguably the most promising treatment of diabetes to date.

  4. Reducing risk of closed loop control of blood glucose in artificial pancreas using fractional calculus.

    Science.gov (United States)

    Ghorbani, Mahboobeh; Bogdan, Paul

    2014-01-01

    Healthcare costs in the US are among the highest in the world. Chronic diseases such as diabetes significantly contribute to these extensive costs. Despite technological advances to improve sensing and actuation devices, we still lack a coherent theory that facilitates the design and optimization of efficient and robust medical cyber-physical systems for managing chronic diseases. In this paper, we propose a mathematical model for capturing the complex dynamics of blood glucose time series (e.g., time dependent and fractal behavior) observed in real world measurements via fractional calculus concepts. Building upon our time dependent fractal model, we propose a novel model predictive controller for an artificial pancreas that regulates insulin injection. We verify the accuracy of our controller by comparing it to conventional non-fractal models using real world measurements and show how the nonlinear optimal controller based on fractal calculus concepts is superior to non-fractal controllers in terms of average risk index and prediction accuracy.

  5. Parathyroidectomy Ameliorates Glucose and Blood Pressure Control in a Patient with Primary Hyperparathyroidism, Type 2 Diabetes, and Hypertension

    Directory of Open Access Journals (Sweden)

    Alok Kumar

    2015-01-01

    Full Text Available Effect of parathyroidectomy on glucose control and hypertension is controversial. Here, we report a case of a patient with primary hyperparathyroidism, type 2 diabetes mellitus, and hypertension in whom parathyroidectomy ameliorated both glucose control and blood pressure. Once high serum calcium levels were noticed, ultrasonography of neck confirmed a well-defined oval hypoechoic mass posterior to the right lobe of the thyroid, confirmed by scintiscan. Parathyroidectomy resulted in improvement of blood pressure and blood glucose. We could stop insulin and antihypertensive medications. We conclude that in patients with type 2 diabetes with vague complaints like fatigue, body ache, and refractory hypertension, as a part of the diagnostic workup, clinicians should also check serum calcium levels and parathyroid hormone to rule out hyperparathyroidism. Correction of hyperparathyroidism may result in improvement of hypertension and glucose control.

  6. Cluster-randomized trial of a mobile phone personalized behavioral intervention for blood glucose control.

    Science.gov (United States)

    Quinn, Charlene C; Shardell, Michelle D; Terrin, Michael L; Barr, Erik A; Ballew, Shoshana H; Gruber-Baldini, Ann L

    2011-09-01

    To test whether adding mobile application coaching and patient/provider web portals to community primary care compared with standard diabetes management would reduce glycated hemoglobin levels in patients with type 2 diabetes. A cluster-randomized clinical trial, the Mobile Diabetes Intervention Study, randomly assigned 26 primary care practices to one of three stepped treatment groups or a control group (usual care). A total of 163 patients were enrolled and included in analysis. The primary outcome was change in glycated hemoglobin levels over a 1-year treatment period. Secondary outcomes were changes in patient-reported diabetes symptoms, diabetes distress, depression, and other clinical (blood pressure) and laboratory (lipid) values. Maximal treatment was a mobile- and web-based self-management patient coaching system and provider decision support. Patients received automated, real-time educational and behavioral messaging in response to individually analyzed blood glucose values, diabetes medications, and lifestyle behaviors communicated by mobile phone. Providers received quarterly reports summarizing patient's glycemic control, diabetes medication management, lifestyle behaviors, and evidence-based treatment options. The mean declines in glycated hemoglobin were 1.9% in the maximal treatment group and 0.7% in the usual care group, a difference of 1.2% (P = 0.001) [corrected] over 12 months. Appreciable differences were not observed between groups for patient-reported diabetes distress, depression, diabetes symptoms, or blood pressure and lipid levels (all P > 0.05). The combination of behavioral mobile coaching with blood glucose data, lifestyle behaviors, and patient self-management data individually analyzed and presented with evidence-based guidelines to providers substantially reduced glycated hemoglobin levels over 1 year.

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ... to the Association. Shopdiabetes.org: Your Stress-Free System for Family Dinners! - 2017-03-book-oclock-scramble. ...

  8. Continuous postoperative blood glucose monitoring and control by artificial pancreas in patients having pancreatic resection: a prospective randomized clinical trial.

    Science.gov (United States)

    Okabayashi, Takehiro; Nishimori, Isao; Yamashita, Koichi; Sugimoto, Takeki; Maeda, Hiromichi; Yatabe, Tomoaki; Kohsaki, Takuhiro; Kobayashi, Michiya; Hanazaki, Kazuhiro

    2009-10-01

    To evaluate a closed-loop system providing continuous monitoring and strict control of perioperative blood glucose following pancreatic resection. Prospective, randomized clinical trial. Thirty patients who had pancreatic resection for pancreatic neoplasm. Patients were prospectively randomized. Perioperative blood glucose levels were continuously monitored using an artificial endocrine pancreas (STG-22). Glucose levels were controlled using either the sliding scale method (sliding scale group, n = 13) or the artificial pancreas (artificial pancreas group, n = 17). Incidence of severe hypoglycemia (artificial pancreas. The secondary outcome measure was the total amount of insulin required for glycemic control in the first 18 hours after pancreatic resection in each patient group. In the sliding scale group, postoperative blood glucose levels rose initially before reaching a plateau of approximately 200 mg/dL between 4 and 6 hours after pancreatectomy. The levels remained high for 18 hours postoperatively. In the artificial pancreas group, blood glucose levels reduced steadily, reaching the target zone (80-110 mg/dL) by 6 hours after surgery. The total insulin dose administered per patient during the first postoperative 18 hours was significantly higher in the artificial pancreas group (mean [SD], 107 [109] IU) than the sliding scale group (8 [6] IU; P artificial endocrine pancreas to control pancreatogenic diabetes after pancreatic resection is an easy and effective way to maintain near-normal blood glucose levels. The artificial pancreas shows promise for use as insulin treatment for patients with pancreatogenic diabetes after pancreatic resection.

  9. Gaps and barriers in the control of blood glucose in people with type 2 diabetes.

    Science.gov (United States)

    Blonde, Lawrence; Aschner, Pablo; Bailey, Clifford; Ji, Linong; Leiter, Lawrence A; Matthaei, Stephan

    2017-05-01

    Glycaemic control is suboptimal in a large proportion of people with type 2 diabetes who are consequently at an increased and avoidable risk of potentially severe complications. We sought to explore attitudes and practices among healthcare professionals that may contribute to suboptimal glycaemic control through a review of recent relevant publications in the scientific literature. An electronic search of the PubMed database was performed to identify relevant publications from January 2011 to July 2015. The electronic search was complemented by a manual search of abstracts from key diabetes conferences in 2014/2015 available online. Recently published data indicate that glycaemic control is suboptimal in a substantial proportion (typically 40%-60%) of people with diabetes. This is the case across geographic regions and in both low- and higher-income countries. Therapeutic inertia appears to be an important contributor to poor glycaemic control in up to half of people with type 2 diabetes. In particular, prescribers are often willing to tolerate extended periods of 'mild' hyperglycaemia as well as having low expectations for their patients. There are often delays of 3 years or longer in initiating or intensifying glucose-lowering therapy when needed. Many people with type 2 diabetes are failed by current management, with approximately half not achieving or maintaining appropriate target blood glucose levels, leaving these patients at increased and avoidable risk of serious complications. Review criteria: The methodology of this review article is detailed in the 'Methods' section.

  10. Diabetes Support Groups Improve Patient’s Compliance and Control Blood Glucose Levels

    Directory of Open Access Journals (Sweden)

    Zamrotul Izzah

    2013-09-01

    Full Text Available Providing information is not enough to improve diabetic patient’s compliance and achieve goals of therapy. Patient’s good awareness as well as emotional and social supports from family and community may play an important role to improve their compliance and clinical outcomes. Therefore, diabetes support groups were developed and each support group consisted of two pharmacists, two nurses, diabetic patients and their family members. A total of 70 type 2 diabetic patient’s were enrolled and randomized into support group 1 and support group 2. Patients in the group 1 received information leaflets only, while patient in the group 2 received pharmacist counselling and information leaflets at each meeting. Patient’s awareness of diabetes and compliance with medications were assessed by a short questionnaire at baseline and final follow-up. Blood glucose and cholesterol levels were also evaluated in both groups. At the end of study, the overall patient’s awareness and compliance improved by 61.5%. The random and fasting blood glucose levels decreased over than 30% in the group 2 and around 14% in the group 1. This study reveals that collaboration between health care professionals and community in the diabetes support group might help diabetic patients to increase their knowledge and compliance with the diabetes therapy as well as glycaemic control.

  11. An artificial pancreas for automated blood glucose control in patients with Type 1 diabetes

    DEFF Research Database (Denmark)

    Schmidt, Signe; Boiroux, Dimitri; Ranjan, Ajenthen

    2015-01-01

    Automated glucose control in patients with Type 1 diabetes is much-coveted by patients, relatives and healthcare professionals. It is the expectation that a system for automated control, also know as an artificial pancreas, will improve glucose control, reduce the risk of diabetes complications...

  12. Knowledge, attitude and practice of exercise for plasma blood glucose control among patients with type-2 diabetes.

    Science.gov (United States)

    Awotidebe, Taofeek O; Adedoyin, Rufus A; Afolabi, Mubaraq A; Opiyo, Rose

    2016-01-01

    Exercise plays significant role in the health outcomes of patients with diabetes, however, little is known about patients' knowledge of exercise for plasma blood glucose control among patients with type-2 diabetes (T2D). This study investigated knowledge, attitude and practice (KAP) of exercise for plasma blood glucose control among patients with T2D. This cross-sectional study recruited 299 patients with T2D (male=105; female=194) from selected government hospitals in Osun State, Nigeria using purposive sampling technique. Validated questionnaires were used to assess of exercise for plasma blood glucose control and socioeconomic status (SES) of the patients. Data were analysed using descriptive and inferential statistics. Alpha level was set at exercise whilst 269(90.0%) had negative attitude to exercise practice. Less than a third, 82(27.4%) engaged in exercise practice for plasma blood glucose control. There was significant association between knowledge and practice of exercise ((2)=12.535; p=0.002). Furthermore, significant associations were found between knowledge and gender ((2)=11.453; p=0.003), and socioeconomic status ((2)=29.127, p=0.001) but not associated with attitude towards exercise (p>0.05). Patients with demonstrated good knowledge of exercise for plasma blood glucose control but reported negative attitude and poor practice of exercise. Copyright © 2016. Published by Elsevier Ltd.

  13. Blood glucose in acute stroke

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj

    2009-01-01

    Blood glucose is often elevated in acute stroke, and higher admission glucose levels are associated with larger lesions, greater mortality and poorer functional outcome. In patients treated with thrombolysis, hyperglycemia is associated with an increased risk of hemorrhagic transformation...... to the risk of inducing potentially harmful hypoglycemia has been raised. Still, basic and observational research is overwhelmingly in support of a causal relationship between blood glucose and stroke outcome and further research on glucose-lowering therapy in acute stroke is highly warranted....

  14. Automated blood glucose control in type 1 diabetes: A review of progress and challenges.

    Science.gov (United States)

    Bertachi, Arthur; Ramkissoon, Charrise M; Bondia, Jorge; Vehí, Josep

    2018-03-01

    Since the 2000s, research teams worldwide have been working to develop closed-loop (CL) systems able to automatically control blood glucose (BG) levels in patients with type 1 diabetes. This emerging technology is known as artificial pancreas (AP), and its first commercial version just arrived in the market. The main objective of this paper is to present an extensive review of the clinical trials conducted since 2011, which tested various implementations of the AP for different durations under varying conditions. A comprehensive table that contains key information from the selected publications is provided, and the main challenges in AP development and the mitigation strategies used are discussed. The development timelines for different AP systems are also included, highlighting the main evolutions over the clinical trials for each system. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Evaluation of detemir in diabetic cats managed with a protocol for intensive blood glucose control.

    Science.gov (United States)

    Roomp, Kirsten; Rand, Jacquie

    2012-08-01

    The aim of this study was to report outcomes using detemir and a protocol aimed at intensive blood glucose control with home monitoring in diabetic cats, and to compare the results with a previous study using the same protocol with glargine. Eighteen cats diagnosed with diabetes and previously treated with other insulins were included in the study. Data was provided by owners who joined the online German Diabetes-Katzen Forum. The overall remission rate was 67%. For cats that began the protocol before or after 6 months of diagnosis, remission rates were 81% and 42%, respectively (P = 0.14). No significant differences were identified between the outcomes for the glargine and detemir studies, with the exception of three possibly interrelated factors: a slightly older median age of the detemir cohort at diabetes diagnosis, a higher rate of chronic renal disease in the detemir cohort and lower maximal dose for insulin detemir.

  16. Effectiveness for self-monitoring of blood sugar on blood glucose control in Turkish patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Baltaci, Davut; Kutlucan, Ali; Ozturk, Serkan; Saritas, Ayhan; Celer, Ahmet; Celbek, Gokham; Deler, Harun; Aydin, Yusuf; Ankarali, Handan

    2012-08-01

    Diabetes mellitus (DM) is a chronic disease requiring continuous monitoring and treatment. Self-monitoring of blood glucose (SMBG) is frequently recommended. The purpose of the study was to evaluate effectiveness of SMBG on metabolic control in Turkish patients with type 2 DM. The cross-sectional study enrolled type 2 diabetic patients without insulin regimen. The participants were assigned to three groups according to status of SMBG: group 1- regular, group 2 - irregular and group 3 - never SMBG implementation. A total of 349 patients were enrolled. There was no significant difference in mean fasting and post-prandial blood glucose, lipid profile values between the groups. The number of patients with high education level in group 1 was higher than groups 2 and 3 (p = 0.001). HbA1c level was higher in groups 2 and 3 than group 1, but not significantly (p = 0.285). Mean spot urinary albumin- creatinine ratio (ACR) in group 1 is significantly lower than in groups 2 and 3 (p = 0.008 and p = 0.044, respectively), but no significant difference was observed between group 2 and 3 (p = 0.473). The study indicated that regular use of SMBG was not superior to irregular/never use of SMBG on glycemic control, but it seemed to be good intervention for prevention of diabetic nephropathy. We suggestively offered that SMBG should be recommended for patients with a high education level to meet the goal of its use, and it should be incorporated into self-management with effective educational intervention.

  17. Accuracy of blood glucose meters for self-monitoring affects glucose control and hypoglycemia rate in children and adolescents with type 1 diabetes.

    Science.gov (United States)

    Boettcher, Claudia; Dost, Axel; Wudy, Stefan A; Flechtner-Mors, Marion; Borkenstein, Martin; Schiel, Ralf; Weitzel, Dieter; Bechtold-Dalla Pozza, Susanne; Wolf, Johannes; Holl, Reinhard W

    2015-04-01

    This study investigated the accuracy of blood glucose meters for self-monitoring and its influence on glycated hemoglobin (HbA1c) levels and the frequency of hypoglycemic coma. Self-measured and simultaneously obtained laboratory blood glucose values from 9,163 patients with type 1 diabetes glucose control and hypoglycemia rates. Depending on the respective subgroup (defined by sex, age, duration of diabetes, mode of insulin therapy), 78.7-94.7% of the self-monitoring of blood glucose (SMBG) values met the old and 79.7-88.6% met the new ISO criteria. In Clarke and Parkes error grid analyses, the percentages of SMBG values in Zone A ranged between 92.8% and 94.6% (Clarke) and between 92.2% and 95.0% (Parkes). The patient group with SMBG devices measuring "far too low" (compared with the laboratory-obtained glucose levels) presented with a higher HbA1c level than those measuring "far too high," "too high," "identical/almost identical," or "too low" (based on quintiles of deviation). Performing "far too high" was associated with the highest rate of hypoglycemic coma in comparison with the other deviation quintiles. This study showed that current SMBG devices fulfilled neither the previous nor the new ISO criteria. Large deviations of the SMBG values from the "true" glucose levels resulted in higher HbA1c levels and markedly increased rates of hypoglycemic events.

  18. Comparable efficacy of self-monitoring of quantitative urine glucose with self-monitoring of blood glucose on glycaemic control in non-insulin-treated type 2 diabetes.

    Science.gov (United States)

    Lu, J; Bu, R F; Sun, Z L; Lu, Q S; Jin, H; Wang, Y; Wang, S H; Li, L; Xie, Z L; Yang, B Q

    2011-08-01

    To assess whether self-monitoring of quantitative urine glucose or blood glucose is effective, convenient and safe for glycaemic control in non-insulin treated type 2 diabetes. Adults with non-insulin treated type 2 diabetes were recruited and randomized into three groups: Group A, self-monitoring with a quantitative urine glucose meter (n = 38); Group B, self monitoring with a blood glucose meter (n=35); Group C, the control group without self monitoring (n=35). All patients were followed up for six months, during which identical diabetes care was provided. There was a significant decrease in HbA1c within each group (p monitoring frequency was significantly higher in Group A than in Group B. The incidence of hypoglycaemia and quality of life scores were similar between the groups. This study suggests that self-monitoring of urine glucose has comparable efficacy on glycaemic control, and facilitates better compliance than blood self monitoring, without influencing the quality of life or risk of hypoglycaemia. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. An artificial pancreas for automated blood glucose control in patients with Type 1 diabetes.

    Science.gov (United States)

    Schmidt, Signe; Boiroux, Dimitri; Ranjan, Ajenthen; Jørgensen, John Bagterp; Madsen, Henrik; Nørgaard, Kirsten

    2015-01-01

    Automated glucose control in patients with Type 1 diabetes is much-coveted by patients, relatives and healthcare professionals. It is the expectation that a system for automated control, also know as an artificial pancreas, will improve glucose control, reduce the risk of diabetes complications and markedly improve patient quality of life. An artificial pancreas consists of portable devices for glucose sensing and insulin delivery which are controlled by an algorithm residing on a computer. The technology is still under development and currently no artificial pancreas is commercially available. This review gives an introduction to recent progress, challenges and future prospects within the field of artificial pancreas research.

  20. Comparison electrical stimulation and passive stretching for blood glucose control type 2 diabetes mellitus patients

    Science.gov (United States)

    Arsianti, Rika Wahyuni; Parman, Dewy Haryanti; Lesmana, Hendy

    2018-04-01

    Physical exercise is one of the cornerstones for management and treatment type 2 diabetes mellitus. But not all people are able to perform physical exercise because of their physical limitation condition. The strategy for those people in this study is electrical stimulation and passive stretching. The aim of this study is to find out the effect of electrical stimulation and passive stretching to lowering blood glucose level. 20 subjects is divided into electrical stimulation and passive stretching group. The provision of electrical stimulation on lower extremities muscles for 30 minutes for electrical stimulation group (N=10). And other underwent passive stretching for 30 minutes (N=10). The result shows that blood glucose level is decrease from 192.9 ± 10.7087 mg/dL to 165.3 ± 10.527 mg/dL for electrical stimulation intervention group while for the passive stretching group the blood glucose decrease from 153 ± 12.468 mg/dL to 136.1 ± 12.346 mg/dL. Both electrical stimulation and passive stretching are effective to lowering blood glucose level and can be proposed for those people restricted to perform exercise.

  1. A fuzzy logic based closed-loop control system for blood glucose level regulation in diabetics.

    Science.gov (United States)

    Ibbini, M S; Masadeh, M A

    2005-01-01

    In this study, a closed-loop system to control the plasma glucose level in patients with diabetes mellitus type 1 is proposed. This control scheme is based on fuzzy logic control theory to maintain a normoglycaemic average of 4.5 mmol 1(-1) and the normal conditions for free plasma insulin concentration in severe initial state; in particular, when the diabetic patient is subjected to a glucose meal disturbance or fluctuations in the measured glucose level due to error in the measuring instrument. The proposed controller has demonstrated superiority over other conventional controlling therapies. While fuzzy logic controllers have shown promising results in many fields, a comparative study is presented with well-known conventional controllers such as Proportional-Integral-Derivative (PID) and continuous insulin infusion control strategies. The simulated results, for the proposed controller, are presented and discussed.

  2. Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative acute kidney injury.

    Science.gov (United States)

    Mita, Naoji; Kawahito, Shinji; Soga, Tomohiro; Takaishi, Kazumi; Kitahata, Hiroshi; Matsuhisa, Munehide; Shimada, Mitsuo; Kinoshita, Hiroyuki; Tsutsumi, Yasuo M; Tanaka, Katsuya

    2017-03-01

    The aim of the present study was to evaluate the usefulness of a closed-loop system (STG-55; Nikkiso, Tokyo, Japan), a type of artificial endocrine pancreas for the continuous monitoring and control of intraoperative blood glucose, for preventing postoperative acute kidney injury (AKI) in patients undergoing hepatectomy. Thirty-eight patients were enrolled in this study. Glucose concentrations were controlled with either a manual injection of insulin based on a commonly used sliding scale (manual insulin group, n = 19) or the programmed infusion of insulin determined by the control algorithm of the artificial endocrine pancreas (programmed insulin group, n = 19). After the induction of anesthesia, a 20-G intravenous catheter was inserted into the peripheral forearm vein of patients in the programmed insulin group and connected to an artificial endocrine pancreas (STG-55). The target range for glucose concentrations was set to 100-150 mg/dL. The mean serum creatinine concentrations of preoperative, postoperative 24 and 48 h were 0.72, 0.78, and 0.79 mg/dL in the programmed insulin group, and 0.81, 0.95, and 1.03 mg/dL in the manual insulin group, respectively. Elevations in serum creatinine concentrations postoperative 48 h were significantly suppressed in the programmed insulin group. The STG-55 closed-loop system was effective for maintaining strict blood glucose control during hepatectomy with minimal variability in blood glucose concentrations and for suppressing elevations in serum creatinine concentrations. Strict blood glucose control by an artificial endocrine pancreas during hepatectomy may prevent postoperative AKI.

  3. Optimal blood glucose level control using dynamic programming based on minimal Bergman model

    Science.gov (United States)

    Rettian Anggita Sari, Maria; Hartono

    2018-03-01

    The purpose of this article is to simulate the glucose dynamic and the insulin kinetic of diabetic patient. The model used in this research is a non-linear Minimal Bergman model. Optimal control theory is then applied to formulate the problem in order to determine the optimal dose of insulin in the treatment of diabetes mellitus such that the glucose level is in the normal range for some specific time range. The optimization problem is solved using dynamic programming. The result shows that dynamic programming is quite reliable to represent the interaction between glucose and insulin levels in diabetes mellitus patient.

  4. Evaluation of serum fructosamine concentration as an index of blood glucose control in cats with diabetes mellitus.

    Science.gov (United States)

    Kaneko, J J; Kawamoto, M; Heusner, A A; Feldman, E C; Koizumi, I

    1992-10-01

    Fructosamine, a glycated serum protein, was evaluated as an index of glycemic control in normal and diabetic cats. Fructosamine was determined manually by use of a modification of an automated method. The within-run precision was 2.4 to 3.2%, and the day-to-day precision was 2.7 to 3.1%. Fructosamine was found to be stable in serum samples stored for 1 week at 4 C and for 2 weeks at -20 C. The reference range for serum fructosamine concentration in 31 clinically normal colony cats was 2.19 to 3.47 mmol/L (mean, 2.83 +/- 0.32 mmol/L). In 27 samples from 16 cats with poorly controlled diabetes mellitus, the range for fructosamine concentration was 3.04 to 8.83 mmol/L (mean, 5.93 +/- 1.35 mmol/L). Fructosamine concentration was directly and highly correlated to blood glucose concentration. Fructosamine concentration also remained high in consort with increased blood glucose concentration in cats with poorly controlled diabetes mellitus over extended periods. It is concluded that measurement of serum fructosamine concentration can be a valuable adjunct to blood glucose monitoring to evaluate glycemic control in diabetic cats. The question of whether fructosamine can replace glucose for monitoring control of diabetes mellitus requires further study.

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... little insulin or when the body can't use insulin properly. What Causes Hyperglycemia? A number of ... enough insulin. Without insulin, your body can't use glucose for fuel, so your body breaks down ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health Insurance Health ... glucose happens when the body has too little insulin or when the body can't use insulin ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Non-starchy Vegetables Grains and Starchy Vegetables Fats Alcohol What Can I Drink? Fruit Dairy Food Tips ... insulin, your body can't use glucose for fuel, so your body breaks down fats to use ...

  9. A semiclosed-loop optimal control system for blood glucose level in diabetics.

    Science.gov (United States)

    Ibbini, M S; Masadeh, M A; Amer, M M Bani

    2004-01-01

    In this manuscript, the well-known Bergman nonlinear mathematical model of the plasma glucose/insulin interaction is adopted and a semi closed-loop optimal technique is proposed for the correction of hyperglycemia in diabetic subjects. Computer simulations are used to evaluate the effectiveness of the proposed technique and to demonstrate its superiority in controlling hyperglycemia over other existing algorithms.

  10. Optimizing insulin injection technique and its effect on blood glucose control

    Directory of Open Access Journals (Sweden)

    Giorgio Grassi, MD

    2014-12-01

    Conclusions: Targeted individualized training in IT, including the switch to a 4 mm needle, is associated with improved glucose control, greater satisfaction with therapy, better and simpler injection practices and possibly lower consumption of insulin after only a three month period.

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood ... For Parents & Kids Safe at School Everyday Life Children and Type 2 Diabetes Know Your Rights Employment ...

  12. Influence of magnesium status and magnesium intake on the blood glucose control in patients with type 2 diabetes.

    Science.gov (United States)

    Sales, Cristiane Hermes; Pedrosa, Lucia Fátima Campos; Lima, Josivan Gomes; Lemos, Telma Maria Araújo Moura; Colli, Célia

    2011-06-01

    This study was undertaken to assess magnesium intake and magnesium status in patients with type 2 diabetes, and to identify the parameters that best predict alterations in fasting glucose and plasma magnesium. A cross-sectional study was carried out in patients with type 2 diabetes (n = 51; 53.6 ± 10.5 y) selected within the inclusion factors, at the University Hospital Onofre Lopes. Magnesium intake was assessed by three 24-h recalls. Urine, plasma and erythrocytes magnesium, fasting and 2-h postprandial glucose, HbA1, microalbuminuria, proteinuria, and serum and urine creatinine were measured. Mean magnesium intake (9.37 ± 1.76 mmol/d), urine magnesium (2.80 ± 1.51 mmol/d), plasma magnesium (0.71 ± 0.08 mmol/L) and erythrocyte magnesium (1.92 ± 0.23 mmol/L) levels were low. Seventy-seven percent of participants presented one or more magnesium status parameters below the cut-off points of 3.00 mmol/L for urine, 0.75 mmol/L for plasma and 1.65 mmol/L for erythrocytes. Subjects presented poor blood glucose control with fasting glucose of 8.1 ± 3.7 mmol/L, 2-h postprandial glucose of 11.1 ± 5.1 mmol/L, and HbA1 of 11.4 ± 3.0%. The parameters that influenced fasting glucose were urine, plasma and dietary magnesium, while plasma magnesium was influenced by creatinine clearance. Magnesium status was influenced by kidney depuration and was altered in patients with type 2 diabetes, and magnesium showed to play an important role in blood glucose control. Copyright © 2011 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  13. All about Blood Glucose

    Science.gov (United States)

    ... may need a change in your meal plan,physical activity,or diabetes medicines.Keep track of when you’ve had ... glucose events.Note possible causes,such as unplanned physical activity.Then talk it over with your ... Diabetes Association    1–800–DIABETES (342–2383)    www. diabetes. ...

  14. Blood glucose response to pea fiber

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    Two new fiber types, pea fiber (PF) and sugar beet fiber (BF), were compared with wheat bran (WB) to investigate the effect on postprandial blood glucose and serum insulin responses in normal subjects. The control meal consisted of 150 g ground beef mixed with 50 g glucose and 20 g lactulose. Only...... addition of PF (15 g pure fiber) reduced the area under the incremental blood glucose curve significantly (by 65%, p less than 0.05). None of the fibers affected the area under the insulin-response curve significantly although it was reduced by all fibers. Mouth-to-cecum transit time, assessed...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... What Can I Drink? Fruit Dairy Food Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... seconds someone new is diagnosed. Diabetes causes more deaths a year than breast cancer and AIDS combined. ... blood, which can lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness ...

  17. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... follow the instructions for operating your meter. your hematocrit (the amount of red blood cells in the ... health care provider can tell you if your hematocrit is low or high, and can discuss with ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High ... Holiday Meal Planning What Can I Eat? Making Healthy Food Choices Diabetes ... Tips Eating Out Quick Meal Ideas Snacks Nutrient Content Claims ...

  19. Cotransplantation of Mesenchymal Stem Cells and Immature Dendritic Cells Potentiates the Blood Glucose Control of Islet Allografts

    Directory of Open Access Journals (Sweden)

    Guanghui Long

    2017-01-01

    Full Text Available Background. Transplantation of islets is a promising alternative to treat type 1 diabetes (T1D, but graft rejection is the major obstacle to its application in clinical practice. We evaluated the effects of mesenchymal stem cells (MSCs and immature dendritic cells (imDCs on islet transplantation in diabetic model. Methods. The streptozotocin T1D model was established in BABL/c mice. Rat islets were isolated and identified with dithizone (DTZ staining. MSCs and imDCs were isolated from bone marrow of syngenic mice. Islets, alone or along with MSCs and/or imDCs, were transplanted to the left kidney capsule of diabetic mice. The blood glucose levels and glycosylated hemoglobin levels after transplantation were monitored. Results. Cotransplantation significantly decreased blood glucose and glycosylated hemoglobin levels in the diabetes mice. Transplantation of 200 islets + 2 × 105 MSCs + 2 × 105 imDCs could not only restore normal blood glucose levels, but also significantly prolong graft survival for 12.6±3.48 days. Conclusions. Cotransplantation of allogenic islets with imDCs and/or MSCs can significantly promote graft survival, reverse hyperglycemia, and effectively control the glycosylated hemoglobin levels.

  20. An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes.

    Science.gov (United States)

    Hu, Ruiqiang; Li, Chengwei

    2015-01-01

    Automated closed-loop insulin infusion therapy has been studied for many years. In closed-loop system, the control algorithm is the key technique of precise insulin infusion. The control algorithm needs to be designed and validated. In this paper, an improved PID algorithm based on insulin-on-board estimate is proposed and computer simulations are done using a combinational mathematical model of the dynamics of blood glucose-insulin regulation in the blood system. The simulation results demonstrate that the improved PID algorithm can perform well in different carbohydrate ingestion and different insulin sensitivity situations. Compared with the traditional PID algorithm, the control performance is improved obviously and hypoglycemia can be avoided. To verify the effectiveness of the proposed control algorithm, in silico testing is done using the UVa/Padova virtual patient software.

  1. An Improved PID Algorithm Based on Insulin-on-Board Estimate for Blood Glucose Control with Type 1 Diabetes

    Science.gov (United States)

    Hu, Ruiqiang; Li, Chengwei

    2015-01-01

    Automated closed-loop insulin infusion therapy has been studied for many years. In closed-loop system, the control algorithm is the key technique of precise insulin infusion. The control algorithm needs to be designed and validated. In this paper, an improved PID algorithm based on insulin-on-board estimate is proposed and computer simulations are done using a combinational mathematical model of the dynamics of blood glucose-insulin regulation in the blood system. The simulation results demonstrate that the improved PID algorithm can perform well in different carbohydrate ingestion and different insulin sensitivity situations. Compared with the traditional PID algorithm, the control performance is improved obviously and hypoglycemia can be avoided. To verify the effectiveness of the proposed control algorithm, in silico testing is done using the UVa/Padova virtual patient software. PMID:26550021

  2. Effect of Guava in Blood Glucose and Lipid Profile in Healthy Human Subjects: A Randomized Controlled Study

    Science.gov (United States)

    Rakavi, R; Mangaraj, Manaswini

    2016-01-01

    Introduction The fruit of Psidium guajava (P.guajava) is known to contain free sugars yet the fruit juice showed hypoglycaemic effect. Hypoglycaemic activity of guava leaves has been well documented but not for guava fruit. Aim So we aimed to evaluate the effect of ripe guava (with peel and without peel) fruit supplementation on blood glucose and lipid profile in healthy human subjects. Materials and Methods Randomized Controlled study undertaken in: 1) Baseline; 2) 6 weeks supplementation phase. Forty five healthy MBBS students were included and randomly enrolled into Group A, Group B and Group C. In Baseline phase: Fasting Plasma Glucose (FPG) and serum lipid profile was done in all 3 groups. Group A were supplemented with 400g of ripe guava with peel and group B without peel, for 6 weeks. Rest 15 treated as control i.e., Group C. Result Supplementation of ripe guava fruit with peel reduced BMI as well as blood pressure (pguava pulp supplementation was not significant. Serum Total cholesterol, Triglycerides and Low Density Lipoprotein Cholesterol (LDLc) levels decreased significantly (pguava pulp without peel may have a favourable effect on lipid levels and blood sugar as well. Conclusion Guava fruit without peel is more effective in lowering blood sugar as well as serum total cholesterol, triglycerides and LDLc. It increases HDLc levels also. PMID:27790420

  3. Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data.

    Science.gov (United States)

    Pickup, John C; Freeman, Suzanne C; Sutton, Alex J

    2011-07-07

    To determine the clinical effectiveness of real time continuous glucose monitoring compared with self monitoring of blood glucose in type 1 diabetes. Meta-analysis of randomised controlled trials. Cochrane database for randomised controlled trials, Ovid Medline, Embase, Google Scholar, lists of papers supplied by manufacturers of continuous glucose monitors, and cited literature in retrieved articles. Studies reviewed Randomised controlled trials of two or more months' duration in men and non-pregnant women with type 1 diabetes that compared real time continuous glucose monitoring with self monitoring of blood glucose and where insulin delivery was the same in both arms. Analysis Two step meta-analysis of individual patient data with the primary outcome of final glycated haemoglobin (HbA(1c)) percentage and area under the curve of hypoglycaemia (glucose concentration glucose monitoring and 443 to self monitoring of blood glucose. The overall mean difference in HbA(1c) for continuous glucose monitoring versus self monitoring of blood glucose was -0.30% (95% confidence interval -0.43% to -0.17%) (-3.0, -4.3 to -1.7 mmol/mol). A best fit regression model of determinants of final HbA(1c) showed that for every one day increase of sensor usage per week the effect of continuous glucose monitoring versus self monitoring of blood glucose increased by 0.150% (95% credibility interval -0.194% to -0.106%) (1.5, -1.9 to -1.1 mmol/mol) and every 1% (10 mmol/mol) increase in baseline HbA(1c) increased the effect by 0.126% (-0.257% to 0.0007%) (1.3, -2.6 to 0.0 mmol/mol). The model estimates that, for example, a patient using the sensor continuously would experience a reduction in HbA(1c) of about 0.9% (9 mmol/mol) when the baseline HbA(1c) is 10% (86 mmol/mol). The overall reduction in area under the curve of hypoglycaemia was -0.28 (-0.46 to -0.09), corresponding to a reduction in median exposure to hypoglycaemia of 23% for continuous glucose monitoring compared with self

  4. Evaluation of PD/PID controller for insulin control on blood glucose regulation in a Type-I diabetes

    Science.gov (United States)

    Mahmud, Farhanahani; Isse, Nadir Hussien; Daud, Nur Atikah Mohd; Morsin, Marlia

    2017-01-01

    This project introduces a simulation of Proportional-Derivative (PD) and Proportional-Integral-Derivative (PID) controller based on a virtual Type 1 Diabetes Mellitus (T1DM) patient: Hovorka diabetic model using MATLAB-Simulink software. The results of these simulations are based on three tuning responses for each controller which are fast, slow and oscillation responses. The main purpose of this simulation is to achieve an acceptable stability and fastness response towards the regulation of glucose concentration using PD and PID controller response with insulin infusion rate. Therefore, in order to analyze and compare the responses of both controller performances, one-day simulations of the insulin-glucose dynamic have been conducted using a typical day meal plan that contains five meals of different bolus size. It is found that the PID closed-loop control with a short rise time is required to retrieve a satisfactory glucose regulation.

  5. Self-monitoring of blood glucose (SMBG) and glycaemic control in Cameroon: Results of the International Diabetes Management Practices Study (IDMPS).

    Science.gov (United States)

    Claude Mbanya, Jean; Aschner, Pablo; Chan, Juliana C N; Jose Gagliardino, Juan; Saji, Jude

    2017-04-01

    This study examined the relationship between self-monitoring of blood glucose (SMBG) and glycaemic control among patients from Cameroon. A minority of patients with diabetes owned a blood glucose meter; of these patients, most performed SMBG inconsistently. The lack of SMBG may be a contributing factor to the poor glycaemic control in the country. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future-without-diabetes-1.html A Future Without Diabetes Donate towards research today and your ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... timing of when you take it. What if it Goes Untreated? Hyperglycemia can be a serious problem ... for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future-without-diabetes-1.html ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Ketones Tight Diabetes Control donate en -- #GiveForDiabetes - givefordiabetes.html #GiveForDiabetes Every 21 seconds, someone is diagnosed with ... Donate Today We Can Help - we-can-help.html Chat Online Chat Closed engagement en -- So…Do ...

  9. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation......Standard diabetes insulin therapy for type 1 diabetes and late stages of type 2 is based on the expected development of blood glucose (BG) both as a consequence of the metabolic glucose consumption as well as of meals and exogenous insulin intake. Traditionally, this is not done explicitly......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  10. Random blood glucose testing in dental practice

    DEFF Research Database (Denmark)

    Barasch, Andrei; Safford, Monika M; Qvist, Vibeke

    2012-01-01

    The prevalence of diabetes mellitus (DM) has been increasing. Instances of patients' not having received a diagnosis have been reported widely, as have instances of poor control of DM or prediabetes among patient's who have the disease. These facts indicate that blood glucose screening is needed....

  11. Color record in self-monitoring of blood glucose improves glycemic control by better self-management.

    Science.gov (United States)

    Nishimura, Akiko; Harashima, Shin-ichi; Honda, Ikumi; Shimizu, Yoshiyuki; Harada, Norio; Nagashima, Kazuaki; Hamasaki, Akihiro; Hosoda, Kiminori; Inagaki, Nobuya

    2014-07-01

    Color affects emotions, feelings, and behaviors. We hypothesized that color used in self-monitoring of blood glucose (SMBG) is helpful for patients to recognize and act on their glucose levels to improve glycemic control. Here, two color-indication methods, color record (CR) and color display (CD), were independently compared for their effects on glycemic control in less frequently insulin-treated type 2 diabetes. One hundred twenty outpatients were randomly allocated to four groups with 2×2 factorial design: CR or non-CR and CD or non-CD. Blood glucose levels were recorded in red or blue pencil in the CR arm, and a red or blue indicator light on the SMBG meter was lit in the CD arm, under hyperglycemia or hypoglycemia, respectively. The primary end point was difference in glycated hemoglobin (HbA1c) reduction in 24 weeks. Secondary end points were self-management performance change and psychological state change. HbA1c levels at 24 weeks were significantly decreased in the CR arm by -0.28% but were increased by 0.03% in the non-CR arm (P=0.044). In addition, diet and exercise scores were significantly improved in the CR arm compared with the non-CR arm. The exercise score showed significant improvement in the CD arm compared with the non-CD arm but without a significant difference in HbA1c reduction. Changes in psychological states were not altered between the arms. CR has a favorable effect on self-management performance without any influence on psychological stress, resulting in improved glycemic control in type 2 diabetes patients using less frequent insulin injection. Thus, active but not passive usage of color-indication methods by patients is important in successful SMBG.

  12. Intensive blood glucose control is safe and effective in diabetic cats using home monitoring and treatment with glargine.

    Science.gov (United States)

    Roomp, Kirsten; Rand, Jacquie

    2009-08-01

    Human diabetic patients routinely self-adjust their insulin dose using a protocol and home monitoring, and perform equally well or outperform physician directed adjustments. The objective of this study was to report the outcome of home monitoring of diabetic cats by owners using a protocol aimed at achieving euglycaemia, using ultra-low carbohydrate diets (10 weeks and/or until remission was achieved. Fifty-five cats diagnosed with diabetes mellitus, whose owners joined the online German Diabetes-Katzen Forum, were included. An overall remission rate of 64% was achieved in the cohort. Significantly higher remission rates were observed if good glycaemic control was achieved soon after diagnosis: 84% for cats started on the protocol within 6 months of diagnosis went into remission, and only 35% for cats that began more than 6 months after diagnosis (Pglucose control. In conclusion, intensive blood glucose control is safe and effective in diabetic cats using home monitoring and treatment with glargine.

  13. Bolus calculator and wirelessly communicated blood glucose measurement effectively reduce hypoglycaemia in type 1 diabetic children - randomized controlled trial.

    Science.gov (United States)

    Ramotowska, Anna; Szypowska, Agnieszka

    2014-02-01

    The aim of this study was to assess the effect of bolus calculator function and wireless communication between insulin pump and blood glucose metre on metabolic control in children with type 1 diabetes, treated with insulin pumps. In this randomized, controlled, 12-week trial, 156 patients, aged 12.9 ± 2.6 years, with a history of diabetes of 5.1 ± 3.3 years and glycated haemoglobin values of 7.3 ± 1.2% (56.3 ± 13.44 mmol/mol) were included. Children were assigned to one of three arms: group A, subjects using bolus calculator and wireless communication between insulin pump and blood glucose metre; group B, subjects using bolus calculator without communication between the devices and group C, control group. Devices were downloaded at 0, 6 and 12 weeks. There were statistically fewer episodes of hypoglycaemia in children using bolus calculator compared with the control group: A versus C (3.8 ± 3.1 versus 7.8 ± 5.13 episodes/2 weeks, respectively, p calculator function significantly more frequently than patients in group B (4.9 ± 3.4 versus 2.5 ± 2.9 times/24 h, respectively, p = 0.0006). No significant differences in glycated haemoglobin levels were found between the experimental and the control groups: group A versus C (p = 0.699). The use of bolus calculator did not influence post-prandial glycaemia, body mass index-SD score or insulin/kg/24 h. Bolus calculator use reduces hypoglycaemic episodes independently of communication between insulin pump and blood glucose metre. Wireless communication between devices results in more frequent bolus calculator use. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Blood glucose response to pea fiber

    DEFF Research Database (Denmark)

    Hamberg, O; Rumessen, J J; Gudmand-Høyer, E

    1989-01-01

    Two new fiber types, pea fiber (PF) and sugar beet fiber (BF), were compared with wheat bran (WB) to investigate the effect on postprandial blood glucose and serum insulin responses in normal subjects. The control meal consisted of 150 g ground beef mixed with 50 g glucose and 20 g lactulose. Only...... addition of PF (15 g pure fiber) reduced the area under the incremental blood glucose curve significantly (by 65%, p less than 0.05). None of the fibers affected the area under the insulin-response curve significantly although it was reduced by all fibers. Mouth-to-cecum transit time, assessed...... by the hydrogen breath technique, was decreased by WB and BF, (p less than 0.05) but not by PF. PF is palatable and may prove beneficial as a fiber supplement for diabetics....

  15. The metabolites in peripheral blood mononuclear cells showed greater differences between patients with impaired fasting glucose or type 2 diabetes and healthy controls than those in plasma.

    Science.gov (United States)

    Kim, Minjoo; Kim, Minkyung; Han, Ji Yun; Lee, Sang-Hyun; Jee, Sun Ha; Lee, Jong Ho

    2017-03-01

    To determine differences between peripheral blood mononuclear cells and the plasma metabolites in patients with impaired fasting glucose or type 2 diabetes and healthy controls. In all, 65 nononobese patients (aged 30-70 years) with impaired fasting glucose or type 2 diabetes and 65 nonobese sex-matched healthy controls were included, and fasting peripheral blood mononuclear cell and plasma metabolomes were profiled. The diabetic or impaired fasting glucose patients showed higher circulating and peripheral blood mononuclear cell lipoprotein phospholipase A 2 activities, high-sensitivity C-reactive protein and tumour necrosis factor-α than controls. Compared with controls, impaired fasting glucose or diabetic subjects showed increases in 11 peripheral blood mononuclear cell metabolites: six amino acids (valine, leucine, methionine, phenylalanine, tyrosine and tryptophan), l-pyroglutamic acid, two fatty acid amides containing palmitic amide and oleamide and two lysophosphatidylcholines. In impaired fasting glucose or diabetic patients, peripheral blood mononuclear cell lipoprotein phospholipase A 2 positively associated with peripheral blood mononuclear cell lysophosphatidylcholines and circulating inflammatory markers, including tumour necrosis factor-α, high-sensitivity C-reactive protein and lipoprotein phospholipase A 2 activities. In plasma metabolites between patients and healthy controls, we observed significant increases in only three amino acids (proline, valine and leucine) and decreases in only five lysophosphatidylcholines. This study demonstrates significant differences in the peripheral blood mononuclear cell metabolome in patients with impaired fasting glucose or diabetes compared with healthy controls. These differences were greater than those observed in the plasma metabolome. These data suggest peripheral blood mononuclear cells as a useful tool to better understand the inflammatory pathophysiology of diabetes.

  16. Influence of obstructive sleep apnea syndrome on blood glucose control and occurrence of chronic diabetic complications in type 2 diabetes patients

    Directory of Open Access Journals (Sweden)

    Ran LIU

    2012-12-01

    Full Text Available Objective  To explore the influence of obstructive sleep apnea syndrome (OSAS on blood glucose control and chronic diabetic complications in type 2 diabetes patients. Methods  The type 2 diabetes patients hospitalized in 307 Hospital of PLA from September 2011 to July 2012 were screened for OSAS with a portable sleep respiration monitor ApneaLinkTM device. According to screening results mentioned above, patients were divided into two groups as OSAS group and control group, whose fasting blood glucose level, 2-h postprandial blood glucose level, HbA1c level, HOMA-IR index and prevalence of diabetic retinopathy (DR, and incidences of diabetic nephropathy (DN, diabetic peripheral neuropathy (DPN, hypertension, and hyperlipidemia were recorded and analyzed for evaluating the relationship between OSAS severity and aforesaid factors. Results  One hundred and forty-five patients completed the protocal with 114 cases (87 males and 27 females stratified in OSAS group and 31 cases (22 males and 9 females in control group. Compared with control group, the average fasting blood glucose level, 2-h postprandial blood glucose level, HbA1c level and HOMA-IR index were significantly higher in OSAS patients (P<0.05. The apnea-hypopnea index (AHI and body mass index (BMI were both independently and positively correlated with the fasting blood glucose (adjust R2=37.1%, AHI 31.1%, 2-h postprandial blood glucose (adjust R2=31.2%, AHI 26.2% and HbA1c levels (adjust R2=38.7%, AHI 33.1% with AHI as the predominant risk factor of patient's poor blood glucose control. HbA1c level (OR5.86, 95%CI 4.64-7.08, suffering from OSAS (OR2.38, 95%CI 1.44-3.32, complicated hypertension (OR1.04, 95%CI 1.02-1.06 and patient's diabetes duration (OR2.10, 95%CI 1.80-2.40 were also independently and positively correlated with DR, and the independent and positive correlation factor of DPN included HbA1c level (OR 8.56, 95%CI 5.86-10.64, OSAS (OR 3.21, 95%CI 1.79-4.62 and hypertension

  17. Comparison between adherence assessments and blood glucose monitoring measures to predict glycemic control in adults with type 1 diabetes: a cross-sectional study.

    Science.gov (United States)

    Telo, Gabriela Heiden; de Souza, Martina Schaan; Andrade, Thais Stürmer; Schaan, Beatriz D'Agord

    2016-01-01

    Adherence to treatment has been defined as the degree to which a patient's behavior corresponds to medical or health advice; however, the most appropriate method to evaluate adherence to diabetes care has yet to be identified. We conducted analyses to compare adherence assessments and blood glucose monitoring measures with regard to their ability to predict glycemic control in adults with type 1 diabetes. We analyzed four instruments to evaluate adherence: Self-Care Inventory-Revised, a self-administered survey; Diabetes Self-Monitoring Profile (DSMP), administered by trained researchers; a categorical (yes/no/sometimes) adherence self-evaluation; and a continuous (0-100) adherence self-evaluation. Blood glucose monitoring frequency was evaluated by self-report, diary, and meter download. Participants (n = 82) were aged 39.0 ± 13.1 years with a mean diabetes duration of 21.2 ± 11.1 years; 27 % monitored blood glucose >4 times/day. The DSMP score was the strongest predictor of glycemic control (r = -0.32, P = 0.004) among adherence assessments, while blood glucose monitoring frequency assessed by meter download was the strongest predictor among blood glucose monitoring measures (r = -40, P self-report assessments had a significant but weak correlation with glycemic control (r ≤ 0.28, P ≤ 0.02). The final adjusted model identified the assessment of blood glucose monitoring frequency by meter download as the most robust predictor of HbA1c (estimate effect size = -0.58, P = 0.003). In efforts to evaluate adherence, blood glucose monitoring frequency assessed by meter download has the strongest relationship with glycemic control in adults with type 1 diabetes.

  18. Effects of structured testing versus routine testing of blood glucose in diabetes self-management: A randomized controlled trial.

    Science.gov (United States)

    Nishimura, Akiko; Harashima, Shin-Ichi; Fujita, Yoshihito; Tanaka, Daisuke; Wang, Yu; Liu, Yanyan; Inagaki, Nobuya

    2017-01-01

    To compare the effects of structured and routine testing regimens used in self-monitoring of blood glucose (SMBG) on glycemic control and diabetes self-management in insulin-naïve type 2 diabetes patients. Sixty-two outpatients with insulin-naïve type 2 diabetes were randomly allocated into two less-frequent SMBG usage groups: a structured testing group (STG) and a routine testing group (RTG). Subjects in STG measured 7-points on SMBG for 3 consecutive days once every two months without daily testing; subjects in RTG measured SMBG 3 times each week before breakfast on Monday and Friday and before dinner on Wednesday. The primary endpoint was HbA1c reduction. The secondary endpoints were change in body weight, blood pressure, treatment change, and self-management performance change. HbA1c levels were significantly decreased by 0.32% (3.50mmol/mol) in STG, partly because physicians changed medications more actively. In contrast, body weight and systolic/diastolic blood pressure were significantly reduced by 0.94kg and 6.8/4.7mmHg, respectively, in RTG, possibly related to the increased diet and exercise score in RTG. Structured testing without daily testing is beneficial for glycemic control; routine testing 3 times a week is more helpful for daily self-management. In low SMBG frequency usage, these two regimens can be utilized according to individual diabetic conditions. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The effect of single low-dose dexamethasone on blood glucose concentrations in the perioperative period: a randomized, placebo-controlled investigation in gynecologic surgical patients.

    Science.gov (United States)

    Murphy, Glenn S; Szokol, Joseph W; Avram, Michael J; Greenberg, Steven B; Shear, Torin; Vender, Jeffery S; Gray, Jayla; Landry, Elizabeth

    2014-06-01

    The effect of single low-dose dexamethasone therapy on perioperative blood glucose concentrations has not been well characterized. In this investigation, we examined the effect of 2 commonly used doses of dexamethasone (4 and 8 mg at induction of anesthesia) on blood glucose concentrations during the first 24 hours after administration. Two hundred women patients were randomized to 1 of 6 groups: Early-control (saline); Early-4 mg (4 mg dexamethasone); Early-8 mg (8 mg dexamethasone); Late-control (saline); Late-4 mg (4 mg dexamethasone); and Late-8 mg (8 mg dexamethasone). Blood glucose concentrations were measured at baseline and 1, 2, 3, and 4 hours after administration in the early groups and at baseline and 8 and 24 hours after administration in the late groups. The incidence of hyperglycemic events (the number of patients with at least 1 blood glucose concentration >180 mg/dL) was determined. Blood glucose concentrations increased significantly over time in all control and dexamethasone groups (from median baselines of 94 to 102 mg/dL to maximum medians ranging from 141 to 161.5 mg/dL, all P < 0.001). Blood glucose concentrations did not differ significantly between the groups receiving dexamethasone (either 4 or 8 mg) and those receiving saline at any measurement time. The incidence of hyperglycemic events did not differ in any of the early (21%-28%, P = 0.807) or late (13%-24%, P = 0.552) groups. Because blood glucose concentrations during the first 24 hours after administration of single low-dose dexamethasone did not differ from those observed after saline administrations, these results suggest clinicians need not avoid using dexamethasone for nausea and vomiting prophylaxis out of concerns related to hyperglycemia.

  20. Whole Grains, Legumes, and the Subsequent Meal Effect: Implications for Blood Glucose Control and the Role of Fermentation

    Directory of Open Access Journals (Sweden)

    Janine A. Higgins

    2012-01-01

    Full Text Available Whole grains and legumes are known to reduce postprandial glycemia and, in some instances, insulinemia. However, the subsequent meal effect of ingesting whole grains and legumes is less well known. That is, inclusion of whole grains or legumes at breakfast decreases postprandial glycemia at lunch and/or dinner on the same day whereas consumption of a whole grain or lentil dinner reduces glycemia at breakfast the following morning. This effect is lost upon milling, processing, and cooking at high temperatures. The subsequent meal effect has important implications for the control of day-long blood glucose, and may be partly responsible for the reduction in diabetes incidence associated with increased whole grain and legume intake. This paper describes the subsequent meal effect and explores the role of acute glycemia, presence of resistant starch, and fermentation of indigestible carbohydrate as the mechanisms responsible for this effect.

  1. Blood glucose control in healthy subject and patients receiving intravenous glucose infusion or total parenteral nutrition using glucagon-like peptide 1

    DEFF Research Database (Denmark)

    Nauck, Michael A; Walberg, Jörg; Vethacke, Arndt

    2004-01-01

    It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition.......It was the aim of the study to examine whether the insulinotropic gut hormone GLP-1 is able to control or even normalise glycaemia in healthy subjects receiving intravenous glucose infusions and in severely ill patients hyperglycaemic during total parenteral nutrition....

  2. Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring.

    Science.gov (United States)

    Kusunoki, Yoshiki; Katsuno, Tomoyuki; Nakae, Rie; Watanabe, Kahori; Akagami, Takafumi; Ochi, Fumihiro; Tokuda, Masaru; Murai, Kazuki; Miuchi, Masayuki; Miyagawa, Jun-ichiro; Namba, Mitsuyoshi

    2015-05-01

    Accurate assessment of blood glucose fluctuation is essential for managing blood glucose control while avoiding hypoglycemia in patients with diabetes mellitus. In this study, blood glucose was measured by continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (T1DM) whom self-monitoring of blood glucose (SMBG) was carried out three or more times per day, and evaluation was performed using blood glucose fluctuation parameters obtained by CGM and SMBG. Twenty-nine insulin-depleted patients with T1DM were enrolled. Their blood glucose fluctuations were measured at the same time by SMBG and CGM, and the correlations were evaluated. Correlations were found between the following values obtained by SMBG and CGM: mean and standard deviation of blood glucose levels, average daily risk range, Morbus value and high-blood-glucose index. The hypoglycemia duration and the nocturnal hypoglycemia duration showed no correlation with any of the blood glucose fluctuation parameters obtained by SMBG. The findings suggest that routine SMBG and glycated hemoglobin (HbA1c) measurement are sufficient for evaluation of hyperglycemia in T1DM. On the other hand, blood glucose fluctuation parameters obtained by SMBG and HbA1c have been shown to have no correlations with either hypoglycemia duration or nocturnal hypoglycemia duration. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    ... systems B and C in the Kampala environ. Conclusion: Some of the blood glucose monitoring systems in Kampala, Uganda are poor performers and may lead to the mismanagement of patients. There is need for a system to ensure national quality control of blood glucose monitoring systems. African Health Sciences 2003; ...

  4. Change in blood glucose level in rats after immobilization

    Science.gov (United States)

    Platonov, R. D.; Baskakova, G. M.; Chepurnov, S. A.

    1981-01-01

    Experiments were carried out on male white rats divided into four groups. In group one the blood glucose level was determined immediately after immobilization. In the other three groups, two hours following immobilization, the blood glucose level was determined every 20 minutes for 3 hours 40 minutes by the glucose oxidase method. Preliminary immobilization for 2 hours removed the increase in the blood glucose caused by the stress reaction. By the 2nd hour of immobilization in the presence of continuing stress, the blood glucose level stabilized and varied within 42 + or - 5.5 and 47 + or - 8.1 mg %. Within 2 hours after the immobilization, the differences in the blood glucose level of the rats from the control groups were statistically insignificant.

  5. Efficacy of self-monitoring of blood glucose versus retrospective continuous glucose monitoring in improving glycaemic control in diabetic kidney disease patients.

    Science.gov (United States)

    Yeoh, Ester; Lim, Boon Khim; Fun, Sharon; Tong, Julia; Yeoh, Lee Ying; Sum, Chee Fang; Subramaniam, Tavintharan; Lim, Su Chi

    2018-03-01

    Patients with diabetic kidney disease (DKD) on anti-diabetic agents, are at greater risk of glycemic variations, both hypoglycemia and hyperglycemia. We aimed to compare glycemic control (using HbA1c) and hypoglycemia incidence in patients with Stage 3 DKD (eGFR 30-60 mL/min per 1.73 m 2 ), receiving retrospective CGM-guided anti-diabetic therapy versus self-monitoring of blood glucose (SMBG) over 3 months. Thirty patients with HbA1c >8% were randomized to 6-day retrospective CGM or SMBG. In the CGM group, CGM was worn at the beginning and 6 weeks. HbA1c, assessment of hypoglycaemia events (self-reported and BG 10 years and on insulin therapy (90%). HbA1c improved significantly from baseline 9.9 ± 1.2 to 9.0 ± 1.5% (P  10 mmol/L) reduced from baseline 65.4 ± 22.4% to 54.6 ± 23.6% (P = 0.033) at 6 weeks, with a non-significant rise in percentage duration in hypoglycaemia from 1.2 ± 2.2% to 4.0 ± 7.0% (P = 0.176). There was no difference in self-reported and documented hypoglycaemia events. In a pilot study of DKD patients, short-term episodic use of CGM reduced time spent in hyperglycaemia range without significantly increasing time-exposure to hypoglycaemia. However, both CGM and SMBG were equally effective in improving glycaemic control. © 2016 Asian Pacific Society of Nephrology.

  6. Immediate Effect of Needling at CV-12 (Zhongwan) Acupuncture Point on Blood Glucose Level in Patients with Type 2 Diabetes Mellitus: A Pilot Randomized Placebo-Controlled Trial.

    Science.gov (United States)

    Kumar, Ranjan; Mooventhan, A; Manjunath, Nandi Krishnamurthy

    2017-08-01

    Diabetes mellitus is a major global health problem. Needling at CV-12 has reduced blood glucose level in diabetic rats. The aim of this study was to evaluate the effect of needling at CV-12 (Zhongwan) on blood glucose level in patients with type 2 diabetes mellitus (T2DM). Forty T2DM patients were recruited and randomized into either the acupuncture group or placebo control group. The participants in the acupuncture group were needled at CV-12 (4 cun above the center of the umbilicus), and those in the placebo control group were needled at a placebo point on the right side of the abdomen (1 cun beside the CV-12). For both groups, the needle was retained for 30 minutes. Assessments were performed prior to and after the intervention. Statistical analysis was performed using SPSS version 16. There was a significant reduction in random blood glucose level in the acupuncture group compared to baseline. No such significant change was observed in the placebo control group. The result of this study suggests that 30 minutes of needling at CV-12 might be useful in reducing blood glucose level in patients with T2DM. Copyright © 2017. Published by Elsevier B.V.

  7. Effects of self-monitoring of blood glucose on diabetes control in a ...

    African Journals Online (AJOL)

    Journal of Endocrinology, Metabolism and Diabetes of South Africa ... The number of patients achieving target glycaemic control increased substantially while the number of patients achieving target total cholesterol and ... Mean HDL cholesterol increased significantly between baseline and 12 months (1.20 ± 0.42 vs.

  8. [Blood glucose and ketone monitoring in type 1 diabetic patients in the controlled environment of a summer camp].

    Science.gov (United States)

    López Siguero, J P; Moreno Molina, J A; Borrás Pérez, M V; Pinzón Martín, J L; Brea Molina, J I; del Pino de la Fuente, A; Parramón Pons, M

    2007-04-01

    Control of blood ketone levels and glycemia is advisable in certain situations in type 1 diabetic children and adolescents. The aims of this study were to assess the relationship between glycemia, ketonemia and ketonuria in children and adolescents in a summer camp under different conditions (fasting, casual hyperglycemia, moderate physical exercise) and to assess the utility of ketonemia determinations in diabetes control during this time. There were 47 participants (25 boys and 22 girls), with a mean HbA1c determination prior to enrollment of 7.7 +/- 1.5 %. The mean age was 11.7 +/- 1.8 years and the mean time from onset of diabetes was 3.0 +/- 2.7 years. The mean body mass index was 18.3 +/- 3.9 kg/m2 (SDS -0.16 +/- 0.44), the mean insulin dose was 0.8 +/- 0.4 U/kg/ day, and the number of doses per day was between 2 and 4 (median = 3). Blood glucose and ketones (both measured with the Optium system, Abbott Diabetes Care) and urine ketones (Ketodiastix, Bayer) were determined in different situations. Statistical analysis was performed with the SPSS 11.5 program. Ketonemia results 45 minutes before and after moderate physical activity showed no significant increase in ketones (0.1 +/- 0.03 vs 0.23 +/- 0.07 mmol/l, ns). Preprandial blood ketone levels of > or = 0.5 mmol/l were found in 17.02 % of participants. Ketonemia was resolved during the first hour in all participants except one, in whom ketonemia resolved in 3 hours. Blood ketones were higher before breakfast than during the rest of the day (0.12 +/- 0.17 vs 0.02 +/- 0.05, p or = 0.5 mmol/l) was 174.5 +/- 64.7 mg/dl, a value slightly higher than the overall mean glycemia value (156.87 +/- 87.8 mg/dl). Ketonuria could not be measured in a high percentage of participants due to the difficulty of obtaining samples (between 24.5 % and 58.6 % in the different study groups). Measurement of glycemia together with ketonemia in a summer camp allows reliable follow-up of glycemic control to be performed. Ketonemia

  9. Effect of Jeju Water on Blood Glucose Levels in Diabetic Patients: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Gwanpyo Koh

    2013-01-01

    Full Text Available Jeju water is the groundwater of Jeju Island, a volcanic island located in Republic of Korea. We investigated whether Jeju water improved glycemic control in patients with diabetes. This was a 12-week single-center, double-blind, randomized, and controlled trial. The subjects daily drank a liter of one of three kinds of water: two Jeju waters (S1 and S2 and Seoul tap water (SS. The primary outcome was the proportion of patients in the per-protocol (PP population achieving glycated hemoglobin (HbA1c < 7.0% at week 12. In total, 196 patients were randomized and analyzed in the intention-to-treat (ITT population (66 consuming S1, 63 consuming S2, and 67 consuming SS; 146 patients were considered in the PP population. There were no significant differences in the primary outcomes of the groups consuming S1, S2, or SS. However, the percentage of patients achieving HbA1c < 8% was significantly higher in the S2 group than in the SS group. In the ITT population, the 12-week HbA1c and fructosamine levels were lower in the S1 group than in the SS group and the 4-, 8-, and 12-week fructosamine levels were lower in the S2 group than in the SS group. Although we failed to achieve the primary outcome, it is possible that the Jeju waters improve glycemic control compared with the Seoul tap water in diabetic patients.

  10. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    , but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...... by the authors at the workshop but were written afterward which allowed to include the findings and conclusions of the various discussions and of course updates. The chapter "Alternative Frameworks for Personalized Insulin-Glucose Models" by Harald Kirchsteiger et al. asks the question whether more and more...... that focus not on the prediction of exact future blood glucose values, but rather on the prediction of changes in the patients’ blood glucose range. The chapter “Accuracy of BG Meters and CGM Systems: Possible Influence Factors for the Glucose Prediction Based on Tissue Glucose Concentrations” by Guido...

  11. [Intelligent interpretation of home monitoring blood glucose data].

    Science.gov (United States)

    Dió, Mihály; Deutsch, Tibor; Biczók, Tímea; Mészáros, Judit

    2015-07-19

    Self monitoring of blood glucose is the cornerstone of diabetes management. However, the data obtained by self monitoring of blood glucose have rarely been used with the highest advantage. Few physicians routinely download data from memory-equipped glucose meters and analyse these data systematically at the time of patient visits. There is a need for improved methods for the display and analysis of blood glucose data along with a modular approach for identification of clinical problems. The authors present a systematic methodology for the analysis and interpretation of self monitoring blood glucose data in order to assist the management of patients with diabetes. This approach utilizes the followings 1) overall quality of glycemic control; 2) severity and timing of hypoglycemia and hyperglycemia; 3) variability of blood glucose readings; 4) various temporal patterns extracted from recorded data and 5) adequacy of self monitoring blood glucose data. Based on reliable measures of the quality of glycaemic control and glucose variability, a prioritized problem list is derived along with the probable causes of the detected problems. Finally, problems and their interpretation are used to guide clinicians to choose therapeutic actions and/or recommend behaviour change in order to solve the problems that have been identified.

  12. Exendin-4 improves blood glucose control in both young and aging normal non-diabetic mice, possible contribution of beta cell independent effects.

    Directory of Open Access Journals (Sweden)

    Rongrong Fan

    Full Text Available AIMS: Type 2 diabetes is highly prevalent in the elderly population. Glucagon like Peptide-1 mimetic such as exendin-4 augments post-prandial insulin secretion. However, the potential influence of aging on the therapeutic effects of this peptide has not been well studied. In this study, we examined the glucose regulatory effects of exendin-4 in mice with different ages. METHODS: We treated 3-month and 20 to 22-month old C57/DBA mice with 10 nM/kg exendin-4 for 10 days with measurements of blood glucose and body weight. We performed OGTT and ITT to evaluate the glucose response and insulin sensitivity. Islet morphology and beta cell mass were measured by immuno-staining and beta cell proliferation was evaluated by BrdU incorporation and PCNA staining. Real-time PCR and western blot were used to measure protein changes in the liver tissue after exendin-4 treatment. RESULTS: Exendin-4 treatment improved glycemic control in both 3-month and 20 to 22-month old mice. In both groups of mice, the blood glucose lowering effect was independent of beta cell function as indicated by unchanged beta cell proliferation, insulin secretion or beta cell mass. Moreover, we found that exendin-4 treatment increased hepatic AKT and FOXO1 phosphorylation and inhibited glucose-6-phosphotase (G6P and Phosphoenolpyruvate carboxykinase (PEPCK expression in young mice, but this effect was attenuated in aging mice while the insulin sensitivity showed no change in the young group but significantly improved in aging mice. CONCLUSION: Based on these data, we conclude that the glucose lowering effect of exendin-4 in normal non-diabetic mice was not blunted by aging. We further showed that although there was slight difference in the glucose modulating mechanism of exendin-4 therapy in young and aged mice, the improved glucose control seemed uncorrelated with increased beta cell mass or insulin secretion.

  13. Wine grape pomace flour improves blood pressure, fasting glucose and protein damage in humans: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Inés Urquiaga

    2015-01-01

    Full Text Available BACKGROUND: The Mediterranean diet is a healthy diet with positive scientific evidence of preventing chronic diseases. Bioactive components support the healthy properties of the Mediterranean diet. Antioxidants and fiber, two components of the Mediterranean diet, are key functional nutrients for healthy eating and nutrition. Wine grape pomace is a rich source of these dietary constituents and may be beneficial for human health. Our hypothesis was that the intake of red wine grape pomace flour (WGPF prepared from red wine grapes (Cabernet Sauvignon variety reduced the metabolic syndrome in humans. To evaluate the effect of WGPF on components of metabolic syndrome we design a 16-week longitudinal intervention study. Thirty-eight males, 30-65 years of age, with at least one component of metabolic syndrome, were randomly assigned to either the intervention group (n = 25 or the control group (n = 13. At lunch, the intervention group was given 20 g of WGPF per day, which contained 10 g of dietary fiber, 822 mg of polyphenols and an antioxidant capacity of 7258 ORAC units. Both groups were asked to maintain their regular eating habits and lifestyles. Clinical evaluation, anthropometric measurements and biochemical blood analyses were done at the beginning and the end of the study. RESULTS: WGPF intake significantly decreased systolic and diastolic blood pressure as well as fasting glucose levels. Plasma γ-tocopherol and δ-tocopherol increased and carbonyl group in plasma protein decreased in WGPT group, significantly. No significant effect was observed for waist circumference, HDL cholesterol, triglycerides, total antioxidant capacity and vitamin C in and between groups. The group-dependent magnitude of the differences between the baseline and final postprandial insulin values and γ-tocopherol concentrations was statistically significant. CONCLUSIONS: The consumption of WGPF-rich in fiber and polyphenol antioxidants, as a food supplement in a

  14. Effect of probiotics and synbiotics on blood glucose: a systematic review and meta-analysis of controlled trials.

    Science.gov (United States)

    Nikbakht, Elham; Khalesi, Saman; Singh, Indu; Williams, Lauren Therese; West, Nicholas P; Colson, Natalie

    2018-02-01

    High fasting blood glucose (FBG) can lead to chronic diseases such as diabetes mellitus, cardiovascular and kidney diseases. Consuming probiotics or synbiotics may improve FBG. A systematic review and meta-analysis of controlled trials was conducted to clarify the effect of probiotic and synbiotic consumption on FBG levels. PubMed, Scopus, Cochrane Library, and Cumulative Index to Nursing and Allied Health Literature databases were searched for relevant studies based on eligibility criteria. Randomized or non-randomized controlled trials which investigated the efficacy of probiotics or synbiotics on the FBG of adults were included. Studies were excluded if they were review articles and study protocols, or if the supplement dosage was not clearly mentioned. A total of fourteen studies (eighteen trials) were included in the analysis. Random-effects meta-analyses were conducted for the mean difference in FBG. Overall reduction in FBG observed from consumption of probiotics and synbiotics was borderline statistically significant (-0.18 mmol/L 95 % CI -0.37, 0.00; p = 0.05). Neither probiotic nor synbiotic subgroup analysis revealed a significant reduction in FBG. The result of subgroup analysis for baseline FBG level ≥7 mmol/L showed a reduction in FBG of 0.68 mmol/L (-1.07, -0.29; ρ probiotics showed a more pronounced reduction of 0.31 mmol/L (-0.58, -0.03; ρ = 0.03) compared to single species trials. This meta-analysis suggests that probiotic and synbiotic supplementation may be beneficial in lowering FBG in adults with high baseline FBG (≥7 mmol/L) and that multispecies probiotics may have more impact on FBG than single species.

  15. The Effect of Probiotic Yogurt on Blood Glucose and cardiovascular Biomarkers in Patients with Type II Diabetes: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mahin Rezaei

    2017-01-01

    Full Text Available Background: Given the high prevalence of type II diabetes and its complications, the evidence regarding the beneficial effects of probiotic yogurt on some cardiovascular biomarkers in diabetic patients is worthy of investigation. Aim: To investigate the effect of probiotic yogurt on blood glucose level and cardiovascular biomarkers in patients with type II diabetes. Method:This randomized, clinical trial was conducted on 90 patients with type II diabetes who visited the 5 Azar diabetes clinic in Gorgan, Iran, in 2014. The intervention group consumed three 100 g packages of probiotic yogurt per day for four weeks, while the control group used an equal amount of plain yogurt. Dietary intake, as well as anthropometric and biochemical parameters were measured before and after the trial. To analyze the data, independent t-test, paired t-test, and analysis of covariance were performed, using SPSS version 18. Results: The mean ages of the intervention and control groups were 50.49±10.92 and 50.13±9.20 years, respectively. In the intervention group, paired t-test showed significant differences between mean levels of blood glucose, cholesterol, low-density lipoprotein (LDL, triglycerides, diastolic blood pressure, and glycated hemoglobin before and after four weeks of daily intake of probiotic yogurt (P0.05. At the end of trial, the independent t-test showed a significant difference between the two groups in terms of mean levels of blood glucose, LDL, triglycerides, blood pressure, and glycated hemoglobin (P

  16. [Therapeutic approaches to improve blood glucose control in a patient with type 2 diabetes on a metformin-sulfonylurea combination].

    Science.gov (United States)

    Scheen, A J; Paquot, N

    2011-04-01

    Beyond lifestyle changes, the management of type 2 diabetes comprises the administration of oral glucose-lowering agents, especially the classical metformin-sulfonylurea combination. If such a dual oral therapy could not (any more) obtain an adequate glucose control, intensified management becomes mandatory. Several therapeutic approaches may be proposed at this stage, with some advantages and disadvantages of each of them. The present clinical case aims at illustrating such difficult therapeutic choice. We will provide the pro-contra arguments concerning each therapeutic alternative and describe the practical modalities of an appropriate management according to the patient's characteristics.

  17. A moderate elevation of blood glucose level increases the effectiveness of thermoradiotherapy in a rat tumor model II. improved tumor control at clinically achievable temperatures

    International Nuclear Information System (INIS)

    Berg, Ad P. van den; Berg-Blok, Anneke E. van den; Kal, Henk B.; Reinhold, Huib S.

    2001-01-01

    Purpose: To assess the therapeutic gain (at the TCD 50 level) that can be obtained by boosting thermoradiotherapy with intravenous glucose infusion at different temperatures. This completes our series of studies to determine the optimal conditions and the effectiveness of glucose administration at clinically achievable glucose levels and treatment temperatures. Methods and Materials: Subcutaneous rat rhabdomyosarcoma BA1112 was irradiated with graded single doses of 300-kV X-rays (dose range 0-60 Gy). Fifteen minutes after irradiation, a 100-min intravenous infusion was started, consisting of either glucose (20% solution, 2.4-3 g/kg/h) or saline as a control. Then heat was applied to the tumors at 42 deg. C or 43 deg. C (water bath) during a subsequent 100-min period of infusion. Tumor control was scored as the absence of palpable growth at 100 days after treatment. Results: Glucose infusion enhanced tumor control independent of temperature in the range 42-43 deg. C. At 42 deg. C, the TCD 50 for X-irradiation decreased by 5.9 Gy (SEM 1.8 Gy), from 41.6 (1.6) to 35.7 (1.5) Gy, and at 43 deg. C from 33.3 (1.6) to 27.3 (1.5) Gy, representing a glucose enhancement ratio of approximately 1.2. At doses corresponding to the TCD 50 at either 42 or 43 deg. C, the addition of glucose increased tumor control from 50% to 70%. An enhancement ratio of 2.1 was found for the combination of irradiation, glucose infusion, and heating at 43 deg. C, with respect to irradiation alone (TCD 50 56.3 Gy, reanalyzed earlier data). The contribution of combined heat and glucose to tumor control represented an additive effect, probably on the hypoxic cell population. Conclusion: Moderate glucose administration (blood concentration 300 mg/100 mL) sizably improves experimental tumor control after combined X-irradiation and hyperthermia under clinically feasible conditions. Clinical treatment should benefit from this additional modality, in particular if unsatisfactory local control rates are due

  18. Relationship between metabolic control and self-monitoring of blood glucose in insulin-treated patients with diabetes mellitus.

    Science.gov (United States)

    Soto González, Alfonso; Quintela Fernández, Niurka; Pumar López, Alfonso; Darias Garzón, Ricardo; Rivas Fernández, Margarita; Barberá Comes, Gloria

    2015-05-01

    To assess the relationship between metabolic control (MC) and frequency of self-monitoring of blood glucose (SMBG) in insulin-treated patients with type 1 (T1DM) and type 2 (T2DM) diabetes mellitus, and to analyze the factors associated to MC. A multicenter, cross-sectional, observational study was conducted in which endocrinologists enrolled diabetic patients treated with insulin who used a glucometer. The cut-off value for MC was HbA1c ≤ 7%. Grade of acceptance of the glucometer was assessed using a visual analogue scale (VAS). A total of 341 patients (53.5% males) with a mean age (SD) 52.8 (16.3) years, mean HbA1c of 7.69% (1.25) and 128 (37.5%) with T1DM and 211 (61.9%) with T2DM were evaluable. SMBG was done by 86.1% at least once weekly. No relationship was seen between MC and SMBG (P=.678) in the overall sample or in the T1DM (P=.940) or T2DM (P=.343) subgroups. In the logistic regression model, hyperglycemic episodes (Exp-b [risk] 1.794, P=0.022), falsely elevated HbA1c values (Exp-b 3.182, P=.005), and VAS (Exp-b 1.269, P=.008) were associated to poor MC in the total sample. Hyperglycemic episodes (Exp-b 2.538, P=.004), falsely elevated HbA1c values (Exp-b 3.125, P=.012), and VAS (Exp-b 1.316, P=.026) were associated to poor MC in the T2DM subgroup, while body mass index (Exp-b 1.143, P=.046) was associated to poor MC in the T1DM subgroup. In this retrospective, non-controlled study on patients with DM treated with insulin who used a glucometer, no relationship was seen between the degree of metabolic control and frequency of use of the glucometer. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  19. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    , but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two......-day workshop on the design, use and evaluation of prediction methods for blood glucose concentration was held at the Johannes Kepler University Linz, Austria. One intention of the workshop was to bring together experts working in various fields on the same topic, in order to shed light from different angles...... Freckmann et al. discusses performance metrics used to characterize the accuracy of continuous glucose measurement devices. This topic is highly relevant for prediction models since many of them rely on the data given by the continuous sensors which are previously calibrated with blood glucose meter...

  20. Effect of sitagliptin on blood glucose control in patients with type 2 diabetes mellitus who are treatment naive or poorly responsive to existing antidiabetic drugs: the JAMP study.

    Science.gov (United States)

    Sakura, Hiroshi; Hashimoto, Naotake; Sasamoto, Kazuo; Ohashi, Hiroshi; Hasumi, Sumiko; Ujihara, Noriko; Kasahara, Tadasu; Tomonaga, Osamu; Nunome, Hideo; Honda, Masashi; Iwamoto, Yasuhiko

    2016-12-01

    To investigate the ameliorating effect of sitagliptin, a dipeptidyl peptidase-4 inhibitor, on blood glucose control in patients with type 2 diabetes mellitus who were previously untreated with or who have a poor responsive to existing antidiabetic drugs. Sitagliptin (50 mg/day) was added on to the pre-existing therapy for type 2 diabetes and changes in the glycated hemoglobin (HbA1c) level after 3 months of treatment were compared with the baseline and performed exploratory analysis. HbA1c levels were significantly decreased after 1 month of treatment compared to baseline, with a mean change in HbA1c level from baseline of -0.73% (range, -0.80 to -0.67) in the entire study population at 3 months. Patients who received a medium dose of glimepiride showed the least improvement in HbA1c levels. The percentage of patients who achieved an HbA1c level of blood glucose level of type 2 diabetes mellitus who were previously untreated with, or poorly responsive to, existing antidiabetic drugs. Thus, sitagliptin is expected to be useful in this patient group. However, the additional administration of sitagliptin in patients treated with medium-dose glimepiride only slightly improved blood glucose control when corrected for baseline HbA1c level.

  1. Self-monitoring of blood glucose versus self-monitoring of urine glucose in adults with newly diagnosed Type 2 diabetes receiving structured education: a cluster randomized controlled trial.

    Science.gov (United States)

    Dallosso, H M; Bodicoat, D H; Campbell, M; Carey, M E; Davies, M J; Eborall, H C; Hadjiconstantinou, M; Khunti, K; Speight, J; Heller, S

    2015-03-01

    To compare the effectiveness and acceptability of self-monitoring of blood glucose with self-monitoring of urine glucose in adults with newly diagnosed Type 2 diabetes. We conducted a multi-site cluster randomized controlled trial with practice-level randomization. Participants attended a structured group education programme, which included a module on self-monitoring using blood glucose or urine glucose monitoring. HbA1c and other biomedical measures as well as psychosocial data were collected at 6, 12 and 18 months. A total of 292 participants with Type 2 diabetes were recruited from 75 practices. HbA1c levels were significantly lower at 18 months than at baseline in both the blood monitoring group [mean (se) -12 (2) mmol/mol; -1.1 (0.2) %] and the urine monitoring group [mean (se) -13 (2) mmol/mol; -1.2 (0.2)%], with no difference between groups [mean difference adjusted for cluster effect and baseline value = -1 mmol/mol (95% CI -3, 2); -0.1% (95% CI -0.3, 0.2)]. Similar improvements were observed for the other biomedical outcomes, with no differences between groups. Both groups showed improvements in total treatment satisfaction, generic well-being, and diabetes-specific well-being, and had a less threatening view of diabetes, with no differences between groups at 18 months. Approximately one in five participants in the urine monitoring arm switched to blood monitoring, while those in the blood monitoring arm rarely switched (18 vs 1% at 18 months; P self-monitoring. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  2. Self-Monitoring of Blood Glucose : The Use of the First or the Second Drop of Blood

    NARCIS (Netherlands)

    Hortensius, Johanna; Slingerland, Robbert J.; Kleefstra, Nanne; Logtenberg, Susan J. J.; Groenier, Klaas H.; Houweling, Sebastiaan T.; Bilo, Henk J. G.

    OBJECTIVE-There is no general agreement regarding the use of the first or second drop of blood for glucose monitoring. This study investigated whether capillary glucose concentrations, as measured in the first and second drops of blood, differed >= 10% compared with a control glucose concentration

  3. Perioperative Glucose Control in Neurosurgical Patients

    Directory of Open Access Journals (Sweden)

    Daniel Agustín Godoy

    2012-01-01

    Full Text Available Many neurosurgery patients may have unrecognized diabetes or may develop stress-related hyperglycemia in the perioperative period. Diabetes patients have a higher perioperative risk of complications and have longer hospital stays than individuals without diabetes. Maintenance of euglycemia using intensive insulin therapy (IIT continues to be investigated as a therapeutic tool to decrease morbidity and mortality associated with derangements in glucose metabolism due to surgery. Suboptimal perioperative glucose control may contribute to increased morbidity, mortality, and aggravate concomitant illnesses. The challenge is to minimize the effects of metabolic derangements on surgical outcomes, reduce blood glucose excursions, and prevent hypoglycemia. Differences in cerebral versus systemic glucose metabolism, time course of cerebral response to injury, and heterogeneity of pathophysiology in the neurosurgical patient populations are important to consider in evaluating the risks and benefits of IIT. While extremes of glucose levels are to be avoided, there are little data to support an optimal blood glucose level or recommend a specific use of IIT for euglycemia maintenance in the perioperative management of neurosurgical patients. Individualized treatment should be based on the local level of blood glucose control, outpatient treatment regimen, presence of complications, nature of the surgical procedure, and type of anesthesia administered.

  4. Effect of Cola acuminate on Blood Glucose and Glycosylated ...

    African Journals Online (AJOL)

    The levels of blood glucose and glycosylated haemoglobin (GHB) were studied in 42 Wistar rats divided into three groups; controls, group A and group B. Control rats consumed only feeds, group A consumed 0.04g of Cola acuminate, while group B consumed 0.08g of Cola acuminate mixed with their feeds daily for six ...

  5. fasting blood glucose and glycosylated haemoglobin levels

    African Journals Online (AJOL)

    Prince Acheampong

    Diabetes Study Group 33). Even though the achievement and maintenance of blood glucose concentrations as near normal as possible are major targets of modern diabetic care (UK Prospective Diabetes Study Group, 1988), this increases the frequency of hypoglycaemia (Amiel 1998). Hypoglycaemia, the most common ...

  6. Nutritional and eating education improves knowledge and practice of patients with type 2 diabetes concerning dietary intake and blood glucose control in an outlying city of China.

    Science.gov (United States)

    Wang, Huan; Song, Zhenfeng; Ba, Yanhui; Zhu, Lin; Wen, Ying

    2014-10-01

    To describe the knowledge, attitudes and practices of type 2 diabetics in Yakeshi City and to assess the effect of implementation of nutritional and eating education in enhancing knowledge and practices regarding a healthy diet. A questionnaire-based survey was conducted with 162 diabetics to determine their nutrition knowledge, attitudes and practices; fifty-four participants received nutritional and eating education for 6 months. Diabetes-related nutrition knowledge, awareness, practice accuracy, dietary intake and glycaemic control were assessed before and after education. Yakeshi, a remote city in northern China. A total of 162 type 2 diabetics recruited from three hospitals, fifty-four of whom were selected randomly to receive education. Among the 162 respondents, most diabetics (75%) considered that controlling diet was important in the methods of controlling blood glucose. Scores for knowledge, practices and overall KAP (knowledge-attitude-practice) were low, but scores for attitude were high. Participants with diabetes education experiences, practice duration over 1 year or high education level all had higher scores for KAP (P education, patients' nutrition knowledge, awareness and practice accuracy improved significantly (P nutrition knowledge and practices. Nutritional and eating education was effective in improving diabetics' nutrition knowledge and practices, and this optimal practice helped them control blood glucose effectively.

  7. A Team-Based Online Game Improves Blood Glucose Control in Veterans With Type 2 Diabetes: A Randomized Controlled Trial.

    Science.gov (United States)

    Kerfoot, B Price; Gagnon, David R; McMahon, Graham T; Orlander, Jay D; Kurgansky, Katherine E; Conlin, Paul R

    2017-09-01

    Rigorous evidence is lacking whether online games can improve patients' longer-term health outcomes. We investigated whether an online team-based game delivering diabetes self-management education (DSME) to patients via e-mail or mobile application (app) can generate longer-term improvements in hemoglobin A 1c (HbA 1c ). Patients ( n = 456) on oral diabetes medications with HbA 1c ≥58 mmol/mol were randomly assigned between a DSME game (with a civics booklet) and a civics game (with a DSME booklet). The 6-month games sent two questions twice weekly via e-mail or mobile app. Participants accrued points based on performance, with scores posted on leaderboards. Winning teams and individuals received modest financial rewards. Our primary outcome measure was HbA 1c change over 12 months. DSME game patients had significantly greater HbA 1c reductions over 12 months than civics game patients (-8 mmol/mol [95% CI -10 to -7] and -5 mmol/mol [95% CI -7 to -3], respectively; P = 0.048). HbA 1c reductions were greater among patients with baseline HbA 1c >75 mmol/mol: -16 mmol/mol [95% CI -21 to -12] and -9 mmol/mol [95% CI -14 to -5] for DSME and civics game patients, respectively; P = 0.031. Patients with diabetes who were randomized to an online game delivering DSME demonstrated sustained and meaningful HbA 1c improvements. Among patients with poorly controlled diabetes, the DSME game reduced HbA 1c by a magnitude comparable to starting a new diabetes medication. Online games may be a scalable approach to improve outcomes among geographically dispersed patients with diabetes and other chronic diseases. © 2017 by the American Diabetes Association.

  8. Effect of inulin-type fructans on blood lipid profile and glucose level: a systematic review and meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Liu, F; Prabhakar, M; Ju, J; Long, H; Zhou, H-W

    2017-01-01

    This systematic review and meta-analysis was performed to assess the effects of inulin-type fructans (ITF) on human blood lipids and glucose homeostasis associated with metabolic abnormalities, including dyslipidemia, overweight or obesity, and type-2 diabetes mellitus (T2DM). The MEDLINE, EMBASE and Cochrane Library databases were systematically searched for randomized controlled trials (RCTs) before January 2016. Human trials that investigated the effects of ITF supplementation on the lipid profile, fasting glucose and insulin were included using Review Manager 5.3. Twenty RCTs with 607 adult participants were included in this systematic review and meta-analysis. In the overall analysis, the supplementation of ITF reduced only the low density lipoprotein-cholesterol (LDL-c) (mean difference (MD): -0.15; 95% confidence interval (CI): -0.29, -0.02; P=0.03) without affecting the other endpoints. Within the T2DM subgroup analysis, ITF supplementation was positively associated with a decreased fasting insulin concentration (MD: -4.01; 95% CI: -5.92, -2.09; P<0.0001) and increased high density lipoprotein-cholesterol (HDL-c) (MD: 0.07; 95% CI: 0, 0.14; P=0.05). Moreover, a reduced fasting glucose tendency was identified only in the T2DM subgroup (MD: -0.42; 95% CI: -0.90, 0.06; P=0.09). There was a potential publication bias, and few trials were available for the T2DM subgroup analysis. In summary, the use of ITF may have benefits for LDL-c reduction across all study populations, whereas HDL-c improvement and glucose control were demonstrated only in the T2DM subgroup. Thus, additional, well-powered, long-term, randomized clinical trials are required for a definitive conclusion. Overall, ITF supplementation may provide a novel direction for improving the lipid profile and glucose metabolism.

  9. Single, community-based blood glucose readings may be a viable alternative for community surveillance of HbA1c and poor glycaemic control in people with known diabetes in resource-poor settings

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2016-08-01

    Full Text Available Background: The term HbA1c (glycated haemoglobin is commonly used in relation to diabetes mellitus. The measure gives an indication of the average blood sugar levels over a period of weeks or months prior to testing. For most low- and middle-income countries HbA1c measurement in community surveillance is prohibitively expensive. A question arises about the possibility of using a single blood glucose measure for estimating HbA1c and therefore identifying poor glycaemic control in resource-poor settings. Design: Using data from the 2011–2012 US National Health and Nutrition Examination Surveys, we examined the relationship between HbA1c and a single fasting measure of blood glucose in a non-clinical population of people with known diabetes (n=333. A linear equation for estimating HbA1c from blood glucose was developed. Appropriate blood glucose cut-off values were set for poor glycaemic control (HbA1c≥69.4 mmol/mol. Results: The HbA1c and blood glucose measures were well correlated (r=0.7. Three blood glucose cut-off values were considered for classifying poor glycaemic control: 8.0, 8.9, and 11.4 mmol/L. A blood glucose of 11.4 had a specificity of 1, but poor sensitivity (0.37; 8.9 had high specificity (0.94 and moderate sensitivity (0.7; 8.0 was associated with good specificity (0.81 and sensitivity (0.75. Conclusions: Where HbA1c measurement is too expensive for community surveillance, a single blood glucose measure may be a reasonable alternative. Generalising the specific results from these US data to low resource settings may not be appropriate, but the general approach is worthy of further investigation.

  10. Screening of gingival crevicular blood glucose and capillary finger blood glucose in the diagnosis of diabetes

    Directory of Open Access Journals (Sweden)

    Alka S Waghmare

    2011-01-01

    Full Text Available Aim: The study aimed at obtaining glucose readings using gingival crevicular blood (GCB to screen for undiagnosed diabetes during routine dental visits. Materials and Methods: The present study included 50 patients who were divided into two groups, i.e. Group A and Group B, based on bleeding on probing at the site of collection of GCB. Group A participants had blood collected from sites having adequate bleeding on probing, whereas Group B participants had blood collected from sites with little bleeding on probing. GCB and capillary finger-stick blood (CFB] glucose readings were obtained using a self-monitoring glucometer. Statistical Analysis: Correlations between both the samples were done using Pearson′s correlation. Results: Group A patients′ correlations between GCB and CFB glucose readings were high, whereas in Group B patients, correlations between glucose readings were low. Conclusion: GCB can be an excellent source for screening diabetes during routine dental visits.

  11. Asymptotic tracking and disturbance rejection of the blood glucose regulation system.

    Science.gov (United States)

    Ashley, Brandon; Liu, Weijiu

    2017-07-01

    Type 1 diabetes patients need external insulin to maintain blood glucose within a narrow range from 65 to 108 mg/dl (3.6 to 6.0 mmol/l). A mathematical model for the blood glucose regulation is required for integrating a glucose monitoring system into insulin pump technology to form a closed-loop insulin delivery system on the feedback of the blood glucose, the so-called "artificial pancreas". The objective of this paper is to treat the exogenous glucose from food as a glucose disturbance and then develop a closed-loop feedback and feedforward control system for the blood glucose regulation system subject to the exogenous glucose disturbance. For this, a mathematical model for the glucose disturbance is proposed on the basis of experimental data, and then incorporated into an existing blood glucose regulation model. Because all the eigenvalues of the disturbance model have zero real parts, the center manifold theory is used to establish blood glucose regulator equations. We then use their solutions to synthesize a required feedback and feedforward controller to reject the disturbance and asymptotically track a constant glucose reference of 90  mg/dl. Since the regulator equations are nonlinear partial differential equations and usually impossible to solve analytically, a linear approximation solution is obtained. Our numerical simulations show that, under the linear approximate feedback and feedforward controller, the blood glucose asymptotically tracks its desired level of 90 mg/dl approximately. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    2001-01-01

    -blockade group vs. the control group, hormones, metabolites, VO(2), and RER followed the same pattern of changes in ACE-blockade and control groups during exercise. Splanchnic blood flow (at rest: 1.67 +/- 0.12, ACE blockade; 1.59 +/- 0.18 l/min, control) decreased during moderate exercise (0.78 +/- 0.07, ACE......, no differences in the pattern of change of splanchnic blood flow and splanchnic glucose production were observed during ACE blockade compared with controls. This study demonstrates that the normal increase in ANG II levels observed during prolonged exercise in humans does not play a major role in the regulation......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin...

  13. Do diabetes mellitus patients adhere to self-monitoring of blood glucose (SMBG) and is this associated with glycemic control? Experiences from a SMBG program in western Kenya.

    Science.gov (United States)

    Wambui Charity, K; Kumar, Ajay M V; Hinderaker, Sven Gudmund; Chinnakali, Palanivel; Pastakia, Sonak D; Kamano, Jemimah

    2016-02-01

    Among diabetes mellitus (DM) patients with poor glycemic control enrolled into a self-monitoring of blood glucose (SMBG) program in Kenya, to assess the level of SMBG adherence, its associated factors and its relation to glycemic control (defined as HbA1c glucose tests performed by the number recommended. A level of ≥ 80% was considered 'good adherence'. Glycemic control was considered as absolute change from baseline of 2%. Of 164 patients (59% female; 76% rural), the proportions with good SMBG adherence were 34%, 17%, 15% and 10% during 0-6, 7-12, 13-18 and 19-24 months into the HGM program respectively. In multivariate analysis, male gender, urban place of residence and payment for glucostrips were associated with poor adherence during 0-12 months. The mean reduction in HbA1c compared to baseline was 1.2%, 1.1%, 0.8% and 0.7% at 6, 12, 18 and 24 months, respectively. We did not find any association between SMBG adherence and glycemic control. Adherence to SMBG was sub-optimal, especially among those who had to pay for glucostrips. Patient education and provision of free glucostrips are recommended to improve adherence and glycemic control. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  14. Changes in blood glucose and plasma lipids during gestation in ...

    African Journals Online (AJOL)

    Ten female Chinchilla rabbits with mean weight (1.9±0.1kg) were randomly assigned into two groups comprising of five each, to evaluate the changes in blood glucose and lipid profile during pregnancy. Control Group A was mated without prior synchronization, while rabbits in group B were synchronized with 0.15mg/kg ...

  15. Fasting blood glucose and glycosylated haemoglobin levels in ...

    African Journals Online (AJOL)

    This work involved the measurement of fasting blood glucose (FBG) and glycosylated haemoglobin (HbA1c) levels of diabetes mellitus patients as an index of glycaemic control. It was a prospective case-finding study using laboratory and general practice records. The subjects were confirmed diabetic patients, attending a ...

  16. Impact Of Administration Mulberry Juice On Blood Glucose, Lipid ...

    African Journals Online (AJOL)

    The aim of the present study was designed to study the effects of black and white mulberry juice on blood glucose, lipid profile and oxidative stress in normal and diabetic rats. Sprague Dawley male rats weighing (125 ± 12.2 g) were divided into eight groups (each of 12 rats). Four healthy control group include normal ...

  17. Random blood glucose may be used to assess long-term glycaemic control among patients with type 2 diabetes mellitus in a rural African clinical setting.

    Science.gov (United States)

    Rasmussen, Jon B; Nordin, Lovisa S; Rasmussen, Niclas S; Thomsen, Jakúp A; Street, Laura A; Bygbjerg, Ib C; Christensen, Dirk L

    2014-12-01

    To investigate the diagnostic accuracy of random blood glucose (RBG) on good glycaemic control among patients with diabetes mellitus (DM) in a rural African setting. Cross-sectional study at St. Francis' Hospital in eastern Zambia. RBG and HbA1c were measured during one clinical review only. Other information obtained was age, sex, body mass index, waist circumference, blood pressure, urine albumin-creatinine ratio, duration since diagnosis and medication. One hundred and one patients with DM (type 1 DM = 23, type 2 DM = 78) were included. Spearman's rank correlation coefficient revealed a significant correlation between RBG and HbA1c among the patients with type 2 DM (r = 0.73, P < 0.001) but not patients with type 1 DM (r = 0.17, P = 0.44). Furthermore, in a multivariate linear regression model (R(2) = 0.71) RBG (per mmol/l increment) (B = 0.28, 95% CI:0.24-0.32, P < 0.001) was significantly associated with HbA1c among the patients with type 2 DM. Based on ROC analysis (AUC = 0.80, SE = 0.05), RBG ≤7.5 mmol/l was determined as the optimal cut-off value for good glycaemic control (HbA1c <7.0% [53 mmol/mol]) among patients with type 2 DM (sensitivity = 76.7%; specificity = 70.8%; positive predictive value = 62.2%; negative predictive value = 82.9%). Random blood glucose could possibly be used to assess glycaemic control among patients with type 2 DM in rural settings of sub-Saharan Africa. © 2014 John Wiley & Sons Ltd.

  18. Cutpoints for screening blood glucose concentrations in healthy senior cats.

    Science.gov (United States)

    Reeve-Johnson, Mia K; Rand, Jacquie S; Vankan, Dianne; Anderson, Stephen T; Marshall, Rhett; Morton, John M

    2017-12-01

    Objectives The objectives of this study were to determine the reference interval for screening blood glucose in senior cats, to apply this to a population of obese senior cats, to compare screening and fasting blood glucose, to assess whether screening blood glucose is predicted by breed, body weight, body condition score (BCS), behaviour score, fasting blood glucose and/or recent carbohydrate intake and to assess its robustness to changes in methodology. Methods The study included a total of 120 clinically healthy client-owned cats aged 8 years and older of varying breeds and BCSs. Blood glucose was measured at the beginning of the consultation from an ear/paw sample using a portable glucose meter calibrated for cats, and again after physical examination from a jugular sample. Fasting blood glucose was measured after overnight hospitalisation and fasting for 18-24 h. Results The reference interval upper limit for screening blood glucose was 189 mg/dl (10.5 mmol/l). Mean screening blood glucose was greater than mean fasting glucose. Breed, body weight, BCS, behaviour score, fasting blood glucose concentration and amount of carbohydrate consumed 2-24 h before sampling collectively explained only a small proportion of the variability in screening blood glucose. Conclusions and relevance Screening blood glucose measurement represents a simple test, and cats with values from 117-189 mg/dl (6.5-10.5 mmol/l) should be retested several hours later. Cats with initial screening blood glucose >189 mg/dl (10.5 mmol/l), or a second screening blood glucose >116 mg/dl (6.4 mmol/l) several hours after the first, should have fasting glucose and glucose tolerance measured after overnight hospitalisation.

  19. Is blood glucose predictable from previous values? A solicitation for data.

    Science.gov (United States)

    Bremer, T; Gough, D A

    1999-03-01

    An important question about blood glucose control in diabetes is, Can present and future blood glucose values be predicted from recent blood glucose history? If this is possible, new continuous blood glucose monitoring technologies under development may lead to qualitatively better therapeutic capabilities. Not only could continuous monitoring technologies alert a user when a hypoglycemic episode or other blood glucose excursion is underway, but measurements may also provide sufficient information to predict near-future blood glucose values. A predictive capability based only on recent blood glucose history would be advantageous because there would be no need to involve models of glucose and insulin distribution, with their inherent requirement for detailed accounting of vascular glucose loads and insulin availability. Published data analyzed here indicate that blood glucose dynamics are not random, and that blood glucose values can be predicted, at least for the near future, from frequently sampled previous values. Data useful in further exploring this concept are limited, however, and an appeal is made for collection of more.

  20. Effect of the LoBAG30 diet on blood glucose control in people with type 2 diabetes.

    Science.gov (United States)

    Nuttall, Frank Q; Schweim, Kelly; Hoover, Heidi; Gannon, Mary C

    2008-03-01

    In subjects with untreated type 2 diabetes, we previously determined that a weight-maintenance, non-ketogenic diet containing 30 % protein, 50 % fat and 20 % carbohydrate (30:50:20) decreased the percentage total glycohaemoglobin (%tGHb) by 2.2 % glycohaemoglobin over 5 weeks compared to a diet recommended for the American public (protein-fat-carbohydrate 15:30:55). Both the fasting and postprandial glucose were decreased. The objective of the present study was to determine if increasing the carbohydrate content from 20 to 30 % at the expense of fat would still provide a similar effect on %tGHb, fasting and postprandial glucose concentration. Eight men with untreated type 2 diabetes were studied over a 5-week period. Results at the beginning (standard diet) and end of the 5-week study were analysed. Body weight was stable. Fasting glucose concentration decreased by 40 %; 24 h glucose area response decreased by 45 %. Insulin did not change. Mean %tGHb decreased by 1.7 (from 10.8 to 9.1 %), and was still decreasing linearly at 5 weeks. In conclusion, a high-protein, 30 % carbohydrate diet could be a patient-empowering method of improving the hyperglycaemia of type 2 diabetes without pharmacologic intervention. Long-term effects and general applicability of this diet remain to be determined.

  1. Fructo-oligosaccharide effects on blood glucose: an overview Efeitos dos fruto-oligossacarídeos no controle glicêmico: revisão

    Directory of Open Access Journals (Sweden)

    Graciana Teixeira Costa

    2012-03-01

    Full Text Available PURPOSE: To identify the current status of scientific knowledge in fructo-oligosaccharides (FOS, non-conventional sugars that play an important role in glycemia control. METHODS: We performed a search for scientific articles in MEDLINE and LILACS databases, from January 1962 to December 2011, using English/Portuguese key words: "blood glucose/glicemia", "prebiotics/prebióticos" and "dietary fiber/fibras na dieta". From an initial number of 434 references, some repeated, 43 references published from 1962 to 2011 were included in this study. The selected texts were distributed in three topics: (1 metabolism of FOS, (2 FOS and experimental studies involving glucose and (3 human studies involving glucose and FOS. RESULTS: Five studies have shown that the use of FOS reduces the fecal content and increases intestinal transit time. Experimental studies have shown that dietary supplementation with high doses (60 g/Kg of propionate, a short-chain fatty acid decreased glycemia. The use of lower doses (3 g/kg did not produce the same results. Study in subjects with diabetes type II showed that the addition of 8 grams of FOS in the diet for 14 days, caused a reduction in serum glucose. In another study with healthy subjects, there were no changes in glycemic control. CONCLUSIONS: This review demonstrates that consumption of FOS has a beneficial influence on glucose metabolism. The controversies appear to be due to inadequate methodological designs and/or the small number of individuals included in some studies.OBJETIVO: Conhecer o estado atual do conhecimento científico em fructooligossacar��deos (FOS, açúcares não-convencionais que desempenham um papel importante no controle da glicemia. MÉTODOS: Realizamos uma busca de artigos científicos nas bases de dados MEDLINE e Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS, a partir de janeiro 1962 a dezembro de 2011, usando como descritores termos Português/Inglês: "glicemia/blood

  2. Body fat content, distribution and blood glucose concentration ...

    African Journals Online (AJOL)

    About 50% of subject who had greater body fat content and waist hip ratio had impaired fasting blood glucose and impaired glucose tolerant. Body fat content within the body has significance effects on blood glucose concentration. Consequently, there is a need of increasing awareness about healthy food consumption ...

  3. Structured self-monitoring of blood glucose regimens improve glycemic control in poorly controlled Chinese patients on insulin therapy: Results from COMPASS.

    Science.gov (United States)

    Ji, Linong; Su, Qing; Feng, Bo; Shan, Zhongyan; Hu, Renming; Xing, Xiaoping; Xue, Yaoming; Yang, Tao; Hua, Yanyin

    2017-05-01

    The use of self-monitoring of blood glucose (SMBG) among patients with insulin-treated, type 2 diabetes (T2DM) in China is suboptimal. Herein we evaluated the effectiveness of structured SMBG for improving glycemic control and increasing the frequency of SMBG. Insulin-treated (>3 months) T2DM patients aged ≥18 years with HbA1c >8.0 % (64 mmol/mol) were recruited to the study. They received SMBG materials and were advised on a structured SMBG regimen for their insulin therapy. Patients were trained to self-adjust insulin dosage according to SMBG readings and were seen by physicians at Months 3 and 6. Endpoints included changes in HbA1c, SMBG frequency, and hypoglycemia frequency. The study enrolled 820 patients, with mean (± SD) age 55.1 ± 9.8 years, body mass index 24.9 ± 3.6 kg/m 2 , HbA1c 9.7 ± 1.6 % (83 mmol/mol), and diabetes duration 9.8 ± 7.1 years, with median insulin therapy of 30.3 (3.0-274.1) months, from 19 Chinese clinics. By Month 3, 99.9 % of patients performed daily SMBG. At Months 3 and 6, HbA1c had decreased from baseline (-1.81 % and -1.73 %, respective; P < 0.0001 for both), with reduced hypoglycemia. In addition, 36.2 % and 39.9 % of patients achieved HbA1c <7.0 % (53 mmol/mol) at Months 3 and 6, respectively. The largest HbA1c improvements were for patients with a shorter duration of diabetes and insulin therapy. A structured SMBG regimen, with training on interpretation of and responses to SMBG readings, increased SMBG frequency and improved HbA1c and the management of insulin-treated T2DM. © 2016 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  4. Influence of Artificial Sweetener on Human Blood Glucose Concentration

    Directory of Open Access Journals (Sweden)

    Ilse Skokan

    2007-01-01

    Full Text Available Artificial sweeteners, such as saccharin or cyclamic acid are synthetically manufactured sweetenings. Known for their low energetic value they serve especially diabetic and adipose patients as sugar substitutes. It has been hypothesized that the substitution of sugar with artificial sweeteners may induce a decrease of the blood glucose. The aim of this study was to determine the reliability of this hypothesis by comparing the influence of regular table sugar and artificial sweeteners on the blood glucose concentration. In this pilot-study 16 patients were included suffering from adiposity, pre-diabetes and hypertension. In the sense of a cross-over design, three test trials were performed at intervals of several weeks. Each trial was followed by a test free interval. Within one test trial each patient consumed 150 ml test solution (water that contained either 6 g of table sugar (“Kandisin” with sweetener free serving as control group. Tests were performed within 1 hr after lunch to ensure conditions comparable to patients having a desert. Every participant had to determine their blood glucose concentration immediately before and 5, 15, 30 and 60 minutes after the intake of the test solution. For statistics an analysis of variance was performed. The data showed no significant changes in the blood glucose concentration. Neither the application of sugar (F4;60 = 1.645; p = .175 nor the consumption of an artificial sweetener (F2.068;31.023 = 1.551; p > .05 caused significant fluctuations in the blood sugar levels. Over a time frame of 60 minutes in the control group a significant decrease of the blood sugar concentration was found (F2.457;36.849 = 4.005; p = .020 as a physiological reaction during lunch digestion.

  5. Spike in glucose levels after reperfusion during aortic surgery: assessment by continuous blood glucose monitoring using artificial endocrine pancreas.

    Science.gov (United States)

    Kawahito, Koji; Sato, Hirotaka; Kadosaki, Mamoru; Egawa, Atsushi; Misawa, Yoshio

    2018-03-01

    Although strict blood glucose control during cardiovascular surgery is essential to avoid postoperative complications, the various changes in glucose levels that occur during surgery have not been investigated in detail. In this study, we continuously monitored blood glucose changes during aortic surgery using the STG-55 Ⓡ artificial endocrine pancreas (Nikkiso Inc., Tokyo). Between December 2015 and 2016, we performed continuous blood glucose monitoring in 22 patients (14 men and 8 women, 72 ± 11 years old), who required hypothermic circulatory arrest during an ascending/aortic arch surgery, at the Jichi Medical University Hospital. Ascending aorta replacements were performed in two patients and partial/total arch replacement, in 20. All the patients required selective cerebral perfusion and hypothermic circulatory arrest (bladder temperature at 25-26 °C) during distal anastomosis. Closed-loop continuous blood glucose monitoring was performed during cardiopulmonary bypass using the STG-55 Ⓡ artificial endocrine pancreas (Nikkiso Co., LTD, Tokyo). Blood glucose concentrations did not increase significantly from the time of the commencement of cardiopulmonary bypass to lower body ischemia. However, they dramatically increased immediately after reperfusion following lower body ischemia, and this hyperglycemia was sustained until the end of cardiopulmonary bypass. The current study clarified the peak glucose concentration during aortic surgery. These data may contribute to the management of blood glucose levels during aortic surgery.

  6. Self-monitoring of Blood Glucose in Non-Insulin Treated Type 2 Diabetes (The SMBG Study): study protocol for a randomised controlled trial.

    Science.gov (United States)

    Parsons, Sharon; Luzio, Stephen; Bain, Stephen; Harvey, John; McKenna, Jillian; Khan, Atir; Rice, Sam; Watkins, Alan; Owens, David R

    2017-01-26

    The benefit of Self-monitoring of Blood Glucose (SMBG) in people with non-insulin treated type 2 diabetes remains unclear with inconsistent evidence from randomised controlled trials fuelling the continued debate. Lack of a consistent finding has been attributed to variations in study population and design, including the SMBG intervention. There is a growing consensus that structured SMBG, whereby the person with diabetes and health care provider are educated to detect patterns of glycaemic abnormality and take appropriate action according to the blood glucose profiles, can prove beneficial in terms of lowering HbA1c and improving overall well-being. Despite this, many national health agencies continue to issue guidelines restricting the use of SMBG in non-insulin treated type 2 diabetes. The SMBG Study is a 12 month, multi-centre, randomised controlled trial in people with type 2 diabetes not on insulin therapy who have poor glycaemic control (HbA1c ≥58 mmol/mol / 7.5%). The participants will be randomised into three comparative groups: Group 1 will act as a control group and receive their usual diabetes care; Group 2 will undertake structured SMBG with clinical review every 3 months; Group 3 will undertake structured SMBG with additional monthly telecare support from a trained study nurse. A total of 450 participants will be recruited from 16 primary and secondary care sites across Wales and England. The primary outcome measure will be HbA1c at 12 months with secondary measures to include weight, BMI, total cholesterol and HbA1c levels at 3, 6, 9 and 12 months. Participant well-being and attitude towards SMBG will be monitored throughout the course of the study. Recruitment began in December 2012 with the last participant visit due in September 2016. This study will attempt to answer the question of whether structured SMBG provides any benefits to people with poorly controlled type 2 diabetes who are not being treated with insulin. The data will also

  7. The effect of monosodium glutamate (MSG) on blood glucose in ...

    African Journals Online (AJOL)

    The animals were grouped into two: groups A (control) and B (Test B1 and Test B2). Group A received water and feed (grower's mash) with grass supplementation. Group B (Test B1 and B2) received 3.33mg/ml and 6.66mg/ml of MSG respectively at libitum. At the end of each week, fasting blood glucose levels were ...

  8. Decision support for optimized blood glucose control and nutrition in a neurotrauma intensive care unit: preliminary results of clinical advice and prediction accuracy of the Glucosafe system.

    Science.gov (United States)

    Pielmeier, Ulrike; Rousing, Mark Lillelund; Andreassen, Steen; Nielsen, Birgitte Steenfeldt; Haure, Pernille

    2012-08-01

    Assessment of glycemic control with model-based decision support ("Glucosafe") in neurotrauma intensive care patients in an ongoing randomized controlled trial with a blood glucose (BG) target of 5-8 mmol/L. Assessment of BG prediction accuracy of the model and assessment of the effect that two potential model extensions would have on prediction accuracy in this trial. In the intervention group insulin infusion rates and nutrition are varied based on Glucosafe's decision support. In the control group, the caloric target is 25-30 kcal/kg per day and insulin is regulated according to department rules. BG concentrations, insulin infusion rates, and feed rates are compared from the data of 12 consecutive patients. BG measurements are predicted retrospectively and the mean relative prediction error is calculated using (1) the current model from the trial, (2) the current model modified by using a BG-dependent variable endogenous insulin appearance rate, (3) the current model modified by a patient-specific carbohydrate absorption factor. BG control was improved by Glucosafe. 76 % of BG measurements in Glucosafe patients were in the 5-8 mmol/L band (Controls: 51 %). BG means (log-normal) ± SD were 7.0 ± 1.19 mmol/L in Glucosafe patients compared to 8.0 ± 1.24 mmol/L in controls (P = 0.05). Mean caloric intake was 93.5 ± 15 % of resting energy expenditure in Glucosafe patients (Controls: 129 ± 29 %). The BG-dependent variable insulin appearance rate had no measurable effect on prediction accuracy. The patient-specific carbohydrate absorption factor improved prediction accuracy significantly (P = 0.001). Glucosafe advice reduces hyperglycemia in neurotrauma intensive care patients. Further parameterization can improve model prediction accuracy.

  9. Effectiveness of a 12-week school-based educational preventive programme on weight and fasting blood glucose in "at-risk" adolescents of type 2 diabetes mellitus: Randomized controlled trial.

    Science.gov (United States)

    Bani Salameh, Ayman; Al-Sheyab, Nihaya; El-Hneiti, Mamdouh; Shaheen, Abeer; Williams, Leonie M; Gallagher, Robyn

    2017-06-01

    To assess the effectiveness of a 12-week school-based educational preventive programme for type 2 diabetes by change in weight and fasting blood glucose level in Jordanian adolescents. Sixteen percent of Jordanian adults have obesity-related type 2 diabetes and 5.6% of obese adolescents examined, however one-third unexamined. Rates in Arabic countries will double in 20 years, but this can be prevented and reversed by controlling obesity. A single-blinded randomized controlled trial was conducted in 2 unisex high schools in Irbid, Jordan, in 2012. Intervention and control participants, aged 12 to 18 years, were visibly overweight/obese. They were randomly allocated to the intervention (n = 205) or control (n = 196) groups. At-risk students were assessed before and after the 12-week intervention, for change in weight and fasting blood glucose level following preventive instruction and parent-supported changes. Mean age of participants was 15.3 years with equal percentages of both males (49.4%) and females. Post intervention, the intervention group, demonstrated statistically significant reductions: mean difference of 3.3 kg in weight (P blood glucose (P blood glucose in Jordanian at-risk adolescents. © 2017 John Wiley & Sons Australia, Ltd.

  10. An artificial pancreas provided a novel model of blood glucose level variability in beagles.

    Science.gov (United States)

    Munekage, Masaya; Yatabe, Tomoaki; Kitagawa, Hiroyuki; Takezaki, Yuka; Tamura, Takahiko; Namikawa, Tsutomu; Hanazaki, Kazuhiro

    2015-12-01

    Although the effects on prognosis of blood glucose level variability have gained increasing attention, it is unclear whether blood glucose level variability itself or the manifestation of pathological conditions that worsen prognosis. Then, previous reports have not been published on variability models of perioperative blood glucose levels. The aim of this study is to establish a novel variability model of blood glucose concentration using an artificial pancreas. We maintained six healthy, male beagles. After anesthesia induction, a 20-G venous catheter was inserted in the right femoral vein and an artificial pancreas (STG-22, Nikkiso Co. Ltd., Tokyo, Japan) was connected for continuous blood glucose monitoring and glucose management. After achieving muscle relaxation, total pancreatectomy was performed. After 1 h of stabilization, automatic blood glucose control was initiated using the artificial pancreas. Blood glucose level varied for 8 h, alternating between the target blood glucose values of 170 and 70 mg/dL. Eight hours later, the experiment was concluded. Total pancreatectomy was performed for 62 ± 13 min. Blood glucose swings were achieved 9.8 ± 2.3 times. The average blood glucose level was 128.1 ± 5.1 mg/dL with an SD of 44.6 ± 3.9 mg/dL. The potassium levels after stabilization and at the end of the experiment were 3.5 ± 0.3 and 3.1 ± 0.5 mmol/L, respectively. In conclusion, the results of the present study demonstrated that an artificial pancreas contributed to the establishment of a novel variability model of blood glucose levels in beagles.

  11. Self-monitoring of blood glucose in non-insulin-treated diabetic patients: a longitudinal evaluation of its impact on metabolic control.

    Science.gov (United States)

    Franciosi, M; Pellegrini, F; De Berardis, G; Belfiglio, M; Di Nardo, B; Greenfield, S; Kaplan, S H; Rossi, M C E; Sacco, M; Tognoni, G; Valentini, M; Nicolucci, A

    2005-07-01

    In the framework of a nationwide outcomes research programme, we assessed the impact of self-monitoring of blood glucose (SMBG) on metabolic control over 3 years in patients with Type 2 diabetes mellitus (DM2) not treated with insulin. The study involved 1896 patients who completed, at 6-month intervals for 3 years, a questionnaire investigating SMBG practice. Clinical information was collected by participating clinicians at the same time intervals. The predictive value of SMBG frequency on long-term metabolic control was estimated using multilevel analysis. The impact of SMBG on metabolic control was also evaluated in distinct and homogeneous subgroups of patients showing different likelihood of performing SMBG, identified using a tree-growing technique (RECPAM). Overall, 22% of the patients were on diet alone and 78% were treated with oral agents; 41% practiced SMBG > or = 1/week (10.3% > or = 1/day). The analysis of metabolic control according to the frequency of SMBG failed to show any significant impact of this practice on HbA1c levels over 3 years. Similarly, changes in SMBG frequency during the study were not related to significant changes in HbA1c levels. RECPAM analysis led to the identification of eight classes, characterized by substantial differences in the likelihood of performing SMBG with a frequency of at least 1/week. Nevertheless, in none of the RECPAM classes identified, did SMBG predict a better metabolic control over 3 years of follow-up. In those RECPAM classes indicating that SMBG was mainly performed to avoid hypoglycaemic episodes, SMBG was associated with a decrease in the frequency of hypoglycaemic episodes during the study. In a large sample of non-insulin-treated Type 2 diabetic patients, the performance and frequency of SMBG did not predict better metabolic control over 3 years. We could not identify any specific subgroups of patients for whom SMBG practice was associated with lower HbA1c levels during the study.

  12. Application of the reference method isotope dilution gas chromatography mass spectrometry (ID/GC/MS) to establish metrological traceability for calibration and control of blood glucose test systems.

    Science.gov (United States)

    Andreis, Elisabeth; Küllmer, Kai; Appel, Matthias

    2014-05-01

    Self-monitoring of blood glucose (BG) by means of handheld BG systems is a cornerstone in diabetes therapy. The aim of this article is to describe a procedure with proven traceability for calibration and evaluation of BG systems to guarantee reliable BG measurements. Isotope dilution gas chromatography mass spectrometry (ID/GC/MS) is a method that fulfills all requirements to be used in a higher-order reference measurement procedure. However, this method is not applicable for routine measurements because of the time-consuming sample preparation. A hexokinase method with perchloric acid (PCA) sample pretreatment is used in a measurement procedure for such purposes. This method is directly linked to the ID/GC/MS method by calibration with a glucose solution that has an ID/GC/MS-determined target value. BG systems are calibrated with whole blood samples. The glucose levels in such samples are analyzed by this ID/GC/MS-linked hexokinase method to establish traceability to higher-order reference material. For method comparison, the glucose concentrations in 577 whole blood samples were measured using the PCA-hexokinase method and the ID/GC/MS method; this resulted in a mean deviation of 0.1%. The mean deviation between BG levels measured in >500 valid whole blood samples with BG systems and the ID/GC/MS was 1.1%. BG systems allow a reliable glucose measurement if a true reference measurement procedure, with a noninterrupted traceability chain using ID/GC/MS linked hexokinase method for calibration of BG systems, is implemented. Systems should be calibrated by means of a traceable and defined measurement procedure to avoid bias. © 2014 Diabetes Technology Society.

  13. Accuracy of handheld blood glucose meters at high altitude.

    Directory of Open Access Journals (Sweden)

    Pieter de Mol

    Full Text Available BACKGROUND: Due to increasing numbers of people with diabetes taking part in extreme sports (e.g., high-altitude trekking, reliable handheld blood glucose meters (BGMs are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior studies reported bias in blood glucose measurements using different BGMs at high altitude. We hypothesized that glucose-oxidase based BGMs are more influenced by the lower atmospheric oxygen pressure at altitude than glucose dehydrogenase based BGMs. METHODOLOGY/PRINCIPAL FINDINGS: Glucose measurements at simulated altitude of nine BGMs (six glucose dehydrogenase and three glucose oxidase BGMs were compared to glucose measurement on a similar BGM at sea level and to a laboratory glucose reference method. Venous blood samples of four different glucose levels were used. Moreover, two glucose oxidase and two glucose dehydrogenase based BGMs were evaluated at different altitudes on Mount Kilimanjaro. Accuracy criteria were set at a bias 6.5 mmol/L and <1 mmol/L from reference glucose (when <6.5 mmol/L. No significant difference was observed between measurements at simulated altitude and sea level for either glucose oxidase based BGMs or glucose dehydrogenase based BGMs as a group phenomenon. Two GDH based BGMs did not meet set performance criteria. Most BGMs are generally overestimating true glucose concentration at high altitude. CONCLUSION: At simulated high altitude all tested BGMs, including glucose oxidase based BGMs, did not show influence of low atmospheric oxygen pressure. All BGMs, except for two GDH based BGMs, performed within predefined criteria. At true high altitude one GDH based BGM had best precision and accuracy.

  14. [Mathematical Modeling of the Blood Glucose Regulation System in Diabetes Mellitus Patients].

    Science.gov (United States)

    Karpel'ev, V A; Filippov, Yu I; Tarasov, Yu V; Boyarsky, M D; Mayorov, A Yu; Shestakova, M V; Dedov, I I

    2015-01-01

    Interest in the mathematical modeling of the carbohydrate metabolism regulation system increases in recent years. This is associated with a "closed loop" insulin pump development (it controls an insulin infusion depending on the blood glucose level). To create an algorithm for the automatic control of insulin (and other hormones) infusion using an insulin pump it is necessary to accurately predict glycaemia level. So, the primary objective of mathematical modeling is to predict the blood glucose level changes, caused by the wide range of external factors. This review discusses the main mathematical models of blood glucose level control physiological system (simplified insulin-glucose system). The two major classes of models--empirical and theoretical--are described in detail. The ideal mathematical model of carbohydrate metabolism regulatory system is absent. However, the success in the field of blood glucose level control modeling and simulating is essentialfor the further development of diabetes prevention and treatment technologies, and creating an artificial pancreas in particular.

  15. Correlation between blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients

    Directory of Open Access Journals (Sweden)

    Fildzah Rahman

    2016-06-01

    Full Text Available Diabetes Mellitus (DM is a syndrome in metabolism of carbohydrates which indicated by the increased level of blood glucose and also may increase salivary glucose levels. Oral ulcer has been frequently recognized in diabetic patients, which can be due to increased glucose in oral fluids and immune dysfunction. This study aimed to determine the correlation of blood glucose levels and salivary glucose levels with oral ulcer in diabetic patients. Analytic observational study was carried out through the determination of blood glucose levels just by way of strip using a glucometer and salivary glucose levels with the method "GOD-PAP test enzymatic colorimetric". Oral ulcer was determined in presenting ulcer on 30 patients with DM. The results showed r = 0.228, which is higher salivary glucose levels followed by high levels of blood glucose, and intraoral examination of oral ulcer found in the whole sample and the most location commonly found in buccal mucosa and lingual. It was concluded that there is a correlation between blood glucose levels and salivary glucose levels, and glucose levels affect the occurrence of oral ulcer in patients with DM

  16. Both the frequency of HbA1c testing and the frequency of self-monitoring of blood glucose predict metabolic control: A multicentre analysis of 15 199 adult type 1 diabetes patients from Germany and Austria.

    Science.gov (United States)

    Schwandt, A; Best, F; Biester, T; Grünerbel, A; Kopp, F; Krakow, D; Laimer, M; Wagner, C; Holl, R W

    2017-10-01

    The objective of this study was to examine the association between metabolic control and frequency of haemoglobin A 1c (HbA 1c ) measurements and of self-monitoring of blood glucose, as well as the interaction of both. Data of 15 199 adult type 1 diabetes patients registered in a standardized electronic health record (DPV) were included. To model the association between metabolic control and frequency of HbA 1c testing or of self-monitoring of blood glucose, multiple hierarchic regression models with adjustment for confounders were fitted. Tukey-Kramer test was used to adjust P values for multiple comparisons. Vuong test was used to compare non-nested models. The baseline variables of the study population were median age 19.9 [Q1; Q3: 18.4; 32.2] years and diabetes duration 10.4 [6.8; 15.7] years. Haemoglobin A 1c was 60.4 [51.5; 72.5] mmol/mol. Frequency of HbA 1c testing was 8.0 [5.0; 9.0] within 2 years, and daily self-monitoring of blood glucose frequency was 5.0 [4.0; 6.0]. After adjustment, a U-shaped association between metabolic control and frequency of HbA 1c testing was observed with lowest HbA 1c levels in the 3-monthly HbA 1c testing group. There was an inverse relationship between self-monitoring of blood glucose and HbA 1c with lower HbA 1c associated with highest frequency of testing (>6 daily measurements). Quarterly HbA 1c testing and frequent self-monitoring of blood glucose were associated with best metabolic control. The adjusted Vuong Z statistic suggests that metabolic control might be better explained by HbA 1c testing compared to self-monitoring of blood glucose (P monitoring together with frequent self-monitoring of blood glucose in diabetes management to reach and maintain target HbA 1c . Copyright © 2017 John Wiley & Sons, Ltd.

  17. Randomized trial of technology-assisted self-monitoring of blood glucose by low-income seniors: improved glycemic control in type 2 diabetes mellitus.

    Science.gov (United States)

    Levine, Jason C; Burns, Edith; Whittle, Jeffrey; Fleming, Raymond; Knudson, Paul; Flax, Steve; Leventhal, Howard

    2016-12-01

    Self-monitoring of blood glucose (SMBG) has been recommended for people with type 2 diabetes mellitus. This trial tested an automated self-management monitor (ASMM) that reminds patients to perform SMBG, provides feedback on results of SMBG, and action tips for improved self-management. This delayed-start trial randomized participants to using the ASMM immediately (IG), or following a delay of 6 months (DG). Glycated hemoglobin (HgbA1c) level and survey data was collected at home visits every 3 months. 44 diabetic men and women, mean age 70, completed the 12-month trial. Baseline HgbA1c was 8.1 % ± 1.0, dropping to 7.3 ± 1.0 by 9 months, with a 3-month lag in the DG (F = 3.56, p = 0.004). Decrease in HgbA1c was significantly correlated to increased frequency of SMBG, R = 0.588, p < 0.01. Providing older diabetics with objective immediate contingent feedback resulted in more frequent SMBG that correlated with better glycemic control. This type of technology may provide real-time feedback not only to patient users, but to the health care system, allowing better integration of provider recommendations with patient-centered action.

  18. Deciding between using the first or second drop of blood for the self monitoring of blood glucose.

    Science.gov (United States)

    Li, Min; Wang, Xiaoli; Shan, Zhongyan

    2014-12-01

    To explore whether the first or the second drop of blood is more suitable for the self-monitoring of blood glucose (SMBG). SMBG was employed in hospitalized patients using the first and second drop of blood. Venous blood glucose was measured meanwhile. The differences in blood glucose measurements were then compared in groups with different regions of blood glucose levels. There were 802 groups of blood glucose in 526 patients. There was no significant difference in the blood glucose levels of the first and second drop of blood and venous blood. However, after combining then dividing measurements into six groups according to blood glucose concentration, we found statistically significant differences between the blood glucose levels obtained from the first drop, second drop, and venous blood in the groups containing blood glucose values blood can be used for performing SMBG to assess real-time venous glucose. By categorizing blood glucose into different levels more accurately, we observed that there was no significant difference between the first or second drop of blood and the venous blood glucose value when blood glucose levels were maintained between 10 and 20 mmol/L. When blood glucose levels were below 10 mmol/L, the value obtained from first drop of blood was close to that from venous blood, whereas when the blood glucose level is >20 mmol/L, the blood glucose value from the second drop of blood was more accurate. Copyright © 2014 Primary Care Diabetes Europe. Published by Elsevier Ltd. All rights reserved.

  19. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  20. Self-monitoring of blood glucose measurements and glycaemic ...

    African Journals Online (AJOL)

    Background. Intensive diabetes management requires intensive insulin treatment and self-monitoring of blood glucose (SMBG) measurements to obtain immediate information on the status of the blood glucose level and to obtain data for pattern analysis on which meal planning, insulin and lifestyle adjustments can be ...

  1. Blood Glucose Lowering Activities Of Seed Of Persea Americana On ...

    African Journals Online (AJOL)

    The n-hexane, chloroform and methanol extracts of Persea americana seeds obtained by cold maceration were assessed for blood glucose lowering activity using two doses of alloxan. The different extracts caused significant blood glucose lowering effect than the glibenclamide in the single dose alloxanized rats but in the ...

  2. Overnight glucose control in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe

    2018-01-01

    This paper presents an individualized model predictive control (MPC) algorithm for overnight blood glucose stabilization in people with type 1 diabetes (T1D). The MPC formulation uses an asymmetric objective function that penalizes low glucose levels more heavily. We compute the model parameters...

  3. Effectiveness of exclusive self-monitoring of fasting capillary blood glucose in the treatment of diabetes

    Directory of Open Access Journals (Sweden)

    Henrique Amancio Ferreira

    2015-07-01

    Full Text Available The study aims to analyze the efficacy of the exclusive self-monitoring of the fasting capillary blood glucose in the control and treatment of diabetic patients. This is a quasi-experimental study, for which five individuals with diabetes were selected, who perform only the fasting capillary blood glucose monitoring, being added about seven other measurements, a variable number according to the individual availability of the volunteer, at different times throughout the day. It was verified that four individuals presented blood glucose values by the use of the fasting capillary blood glucose monitoring, within the parameters of normality for diabetics, between 70-130 mg dL-1 of blood (ADA, 2014b, although in the other measurements, they presented values far from the ideal goal, in a significant part of the time. The study outlines a trend that shows that the glycemic monitoring values based solely on the fasting capillary blood glucose is ineffective, since they can erroneously indicate satisfactory control of the blood glucose levels. Based on the results obtained, to a more effective monitoring and which denotes levels of reliability, it is required at least three measurements of capillary blood glucose throughout the day, and also, the importance of long laboratory tests for glycemic monitoring, such as glycated hemoglobin.

  4. The clinical performance of the EGV1 self-monitoring blood glucose system.

    Science.gov (United States)

    Chen, Chien-Chih; Lin, Jui-Jane; Hung, Sheng-tien; Chun, Peng-Ting; Lai, Yiu-Kay

    2012-07-11

    The novel technique of blood volume detection can improve the reliability and accuracy of a self-monitoring blood glucose system. Self-management of diabetes can be improved, and the glycemic range can be efficiently controlled. A total of 153 patients with diabetes mellitus participated in the clinical study. The accuracy, blood volume detection, interference, and altitude effect of the EGV1 self-monitoring blood glucose system were evaluated and compared among the fingerstick, alternative site testing, and venous blood. The EGV1 self-monitoring blood glucose system with fingertip demonstrated an excellent correlation with venous blood (linear regression analysis: slope=1.01, intercept=-0.8972 mg/dl, r(2)=0.96), and with other brands of glucose systems (linear regression analysis: slope=0.99, intercept=+3.5632 mg/dl, r(2)=0.94). The Clarke error grid analysis indicated that the results of fingertip and alternative sites were in the acceptable zones, A and B. The system required 0.6 ul of a blood sample to obtain an accurate reading, and was unaffected by several interferents and altitude. The EGV1 self-monitoring blood glucose system using various blood samples demonstrated acceptable accuracy and reliability compared to the laboratory reference and other self-monitoring blood glucose systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Prospective Study of Fasting Blood Glucose and Intracerebral Hemorrhagic Risk.

    Science.gov (United States)

    Jin, Cheng; Li, Guohong; Rexrode, Kathryn M; Gurol, Mahmut E; Yuan, Xiaodong; Hui, Ying; Ruan, Chunyu; Vaidya, Anand; Wang, Yanxiu; Wu, Shouling; Gao, Xiang

    2018-01-01

    Although diabetes mellitus is an established independent risk factor for ischemic stroke, the association between fasting blood glucose and intracerebral hemorrhage (ICH) is limited and inconsistent. The objective of the current study was to examine the potential impact of long-term fasting blood glucose concentration on subsequent risk of ICH. This prospective study included 96 110 participants of the Kailuan study, living in Kailuan community, Tangshan city, China, who were free of cardiovascular diseases and cancer at baseline (2006). Fasting blood glucose concentration was measured in 2006, 2008, 2010, and 2012. Updated cumulative average fasting blood glucose concentration was used as primary exposure of the current study. Incident ICH from 2006 to 2015 was confirmed by review of medical records. During 817 531 person-years of follow-up, we identified 755 incident ICH cases. The nadir risk of ICH was observed at fasting blood glucose concentration of 5.3 mmol/L. The adjusted hazard ratios and their 95% confidence intervals (CIs) of ICH were 1.59 (95% CI, 1.26-2.02) for diabetes mellitus or fasting blood glucose ≥7.00 mmol/L, 1.31 (95% CI, 1.02-1.69) for impaired fasting blood glucose (fasting blood glucose, 6.10-6.99 mmol/L), 0.98 (95% CI, 0.78-1.22) for fasting blood glucose 5.60 to 6.09 mmol/L, and 2.04 (95% CI, 1.23-3.38) for hypoglycemia (fasting blood glucose, fasting blood glucose 4.00 to 5.59 mmol/L. The results persisted after excluding individuals who used hypoglycemic, aspirin, antihypertensive agents, or anticoagulants, and those with intracerebral hemorrhagic cases occurred in the first 2 years of follow-up. In this large community-based cohort, low (fasting blood glucose concentrations were associated with higher risk of incident ICH, relative to fasting blood glucose concentrations of 4.00 to 6.09 mmol/L. © 2017 American Heart Association, Inc.

  6. Fasting Blood Glucose Levels in Different Haemoglobin Genotypes ...

    African Journals Online (AJOL)

    For the different Hb genotypes (HBAA, HBAS, HBSC and HBSS) the following mean fasting blood glucose levels were obtained respectively: 71.9±8.Omg/dl 73.4±7.4mgldl, 94.7±6.Imgldl and 94.6±5.9mgldl. There was a significant difference between the mean fasting blood glucose concentrations of blood groups O,A,B and ...

  7. Evaluation of four portable blood glucose meters in diabetic and non-diabetic dogs and cats.

    Science.gov (United States)

    Kang, Min-Hee; Kim, Do-Hyung; Jeong, In-Seong; Choi, Gab-Chol; Park, Hee-Myung

    2016-01-01

    Monitoring of an animal's blood glucose concentration is critical for diagnostic and therapeutic decisions. Over the past few decades, portable blood glucose meters (PBGMs) have been used to monitor blood glucose concentrations in animals. Recently, new and improved PBGMs have been made available on the market. The purpose of this study was to evaluate four PBGMs for use in dogs and cats. A total of 155 venous blood samples of dogs and 85 venous blood samples of cats were tested using four PBGMs. Control solutions from manufacturers were used to determine the precision of each meter. The coefficient of variation was calculated to determine precision during a set of replicates. Pearson's correlation analysis, Passing-Bablok regression, and Bland-Altman analysis were used to determine the accuracy of four PBGMs against the hexokinase reference method. Error grid analysis was used to evaluate clinical relevance. All PBGMs, except CERA-PET®, were clinically acceptable for monitoring blood glucose concentrations; AlphaTrak® and VetMate® appeared to be the most accurate ones, demonstrating that to use PBGMs for glucose monitoring, it is important to understand the strengths or limitations of each meter. The difference in results between the PBGMs and the reference method increased at high glucose concentration ranges, which were also affected by the hematocrit. Although readings of the PBGMs and the reference method varied across glycemic ranges (low, normal, and high glucose concentrations), most PBGMs were clinically acceptable for monitoring blood glucose concentrations in dogs and cats.

  8. Short-term effect of add on bell pepper (Capsicum annuum var. grossum) juice with integrated approach of yoga therapy on blood glucose levels and cardiovascular functions in patients with type 2 diabetes mellitus: A randomized controlled study.

    Science.gov (United States)

    Nagasukeerthi, Padakandla; Mooventhan, A; Manjunath, N K

    2017-10-01

    Type 2 diabetes mellitus (T2DM) is a major global health problem. Though various studies have reported the beneficial effect of Yoga in patient with T2DM, there is a lack of study in combination with bell pepper and yoga. Hence, the present study aims at evaluating short-term effect of add on bell pepper juice with integrated approach of yoga therapy (IAYT) on blood glucose levels and cardiovascular variables in patients with T2DM. Fifty T2DM subjects with the age varied from 34 to 69-years were recruited and randomly divided into either study group or control group. The study group received 100-ml of bell pepper juice (twice/day) along with IAYT while the control group received only IAYT for 4-consecutive days. Baseline and post-test assessments were taken before and after the intervention. Statistical analysis was performed using statistical package for the social sciences, version-16. Results of this study showed no significant difference in overall (fasting and post prandial) blood glucose level in the study group compared with control group. However, a significant reduction in Post prandial blood glucose (PPBG), systolic blood pressure (SBP), pulse pressure (PP), rate pressure product (RPP) and Double product (Do-P) was observed in the study group compared with control group. Results of this study suggest that though an addition of 100-ml of bell pepper juice (twice/day) along with IAYT is not more effective in reducing fasting blood glucose, it may be more effective in reducing PPBG, SBP, PP, RPP and Do-P than IAYT alone. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Korean red ginseng improves glucose control in subjects with impaired fasting glucose, impaired glucose tolerance, or newly diagnosed type 2 diabetes mellitus.

    Science.gov (United States)

    Bang, Hyangju; Kwak, Jung Hyun; Ahn, Hyeon Yeong; Shin, Dong Yeob; Lee, Jong Ho

    2014-01-01

    This study was designed to evaluate the effect of Korean red ginseng (KRG) supplementation on glucose control in subjects with impaired fasting glucose (IFG), impaired glucose tolerance (IGT), or newly diagnosed type 2 diabetes mellitus (T2DM). The study was a 12-week randomized, double-blinded, placebo-controlled (5 g of KRG [n=21] or placebo [n=20] in tablet form) trial. Glucose-related biomarkers, including serum and whole blood levels of glucose, insulin, and C-peptide, were measured by 2-h oral glucose tolerance tests (OGTTs) at baseline and after the 12-week intervention. After the intervention, the test group showed a significant decrease in serum levels of glucose at 30 min (-22.24±10.77 mg/dL) and whole blood levels of glucose at 30 min (-17.52±5.22 mg/dL). In addition, the test group tended to have lower whole blood levels of glucose at 0 min and glucose area under curve (AUC). However, the placebo group did not show any changes in blood glucose-related indices. The changes (difference from baseline) in serum glucose levels at 30 min, whole blood glucose levels at 60 min, and glucose AUC during OGTTs in the test group exhibited a tendency toward a decrease from those in the placebo group. There were significant decreases or trends toward a decrease in both serum insulin and C-peptide concentrations at most time intervals in the test group. In conclusion, KRG supplementation (5 g/day) may be beneficial for controlling serum and whole blood glucose levels compared with placebo among patients with IFG, IGT, or T2DM.

  10. The DiGEM trial protocol – a randomised controlled trial to determine the effect on glycaemic control of different strategies of blood glucose self-monitoring in people with type 2 diabetes [ISRCTN47464659

    Directory of Open Access Journals (Sweden)

    Goyder Elizabeth

    2005-06-01

    Full Text Available Abstract Background We do not yet know how to use blood glucose self-monitoring (BGSM most effectively in the self-management of type 2 diabetes treated with oral medication. Training in monitoring may be most effective in improving glycaemic control and well being when results are linked to behavioural change. Methods/design DiGEM is a three arm randomised parallel group trial set in UK general practices. A total of 450 patients with type 2 diabetes managed with lifestyle or oral glucose lowering medication are included. The trial compares effectiveness of three strategies for monitoring glycaemic control over 12 months (1 a control group with three monthly HbA1c measurements; interpreted with nurse-practitioner; (2 A self-testing of blood glucose group; interpreted with nurse- practitioner to inform adjustment of medication in addition to 1; (3 A self-monitoring of blood glucose group with personal use of results to interpret results in relation to lifestyle changes in addition to 1 and 2. The trial has an 80% power at a 5% level of significance to detect a difference in change in the primary outcome, HbA1c of 0.5% between groups, allowing for an attrition rate of 10%. Secondary outcome measures include health service costs, well-being, and the intervention effect in sub-groups defined by duration of diabetes, current management, health status at baseline and co-morbidity. A mediation analysis will explore the extent to which changes in beliefs about self-management of diabetes between experimental groups leads to changes in outcomes in accordance with the Common Sense Model of illness. The study is open and has recruited more than half the target sample. The trial is expected to report in 2007. Discussion The DiGEM intervention and trial design address weaknesses of previous research by use of a sample size with power to detect a clinically significant change in HbA1c, recruitment from a well-characterised primary care population, definition

  11. Effects of yogic exercises on life stress and blood glucose levels in nursing students.

    Science.gov (United States)

    Kim, Sang Dol

    2014-12-01

    [Purpose] This study was performed to investigate the effects of yogic exercises on life stress and blood glucose levels in nursing students. [Subjects and Methods] The study was a randomized controlled trial. Twenty-seven undergraduate nursing students were randomly selected, with 12 assigned to an exercise group and 15 assigned to a control group. The yogic exercises intervention was undertaken for 60 minutes one day a week for 12 weeks. It consisted of physical exercise (surya namaskara) combined with relaxation and meditation (shavasana and yoga nidra). Life stress was measured by the Life Stress Scale for College Students, and postprandial blood glucose levels were measured with a digital glucometer. [Results] The exercise group measurements were significantly decreased in both life stress and postprandial blood glucose levels compared with the control group. [Conclusion] These findings indicate that yogic exercises would reduce life stress and lower postprandial blood glucose levels in nursing students.

  12. Elevated albumin excretion and retinal changes in children with type 1 diabetes are related to long-term poor blood glucose control

    DEFF Research Database (Denmark)

    Nørgaard, K; Storm, Birgit Kjærside; Graae, M

    1989-01-01

    All diabetic children (n = 113) under 19 years old and with more than 2 years of diabetes attending the Steno Memorial Hospital in 1987 were studied. Normal urinary albumin excretion (less than 30 mg 24 h-1) was found in 96 patients (85%), 15 had microalbuminuria (30-300 mg 24 h-1) (13%), and 2...... patients were proteinuric (greater than 300 mg 24 h-1) (2%). Retinal morphology was evaluated by colour fundus photography. Background retinopathy was more frequent in the group with elevated albumin excretion (71%) than in a matched normoalbuminuric group (20%, 2p less than 0.001). Long-term blood glucose...

  13. The fluctuation of blood glucose, insulin and glucagon concentrations before and after insulin therapy in type 1 diabetes

    Science.gov (United States)

    Arif, Idam; Nasir, Zulfa

    2015-09-01

    A dynamical-systems model of plasma glucose, insulin and glucagon concentrations has been developed to investigate the effects of insulin therapy on blood glucose, insulin and glucagon regulations in type 1 diabetic patients. Simulation results show that the normal regulation of blood glucose concentration depends on insulin and glucagon concentrations. On type 1 diabetic case, the role of insulin on regulating blood glucose is not optimal because of the destruction of β cells in pancreas. These β cells destructions cause hyperglycemic episode affecting the whole body metabolism. To get over this, type 1 diabetic patients need insulin therapy to control the blood glucose level. This research has been done by using rapid acting insulin (lispro), long-acting insulin (glargine) and the combination between them to know the effects of insulin therapy on blood glucose, insulin and glucagon concentrations. Simulation results show that these different types of insulin have different effects on blood glucose concentration. Insulin therapy using lispro shows better blood glucose control after consumption of meals. Glargin gives better blood glucose control between meals and during sleep. Combination between lispro and glargine shows better glycemic control for whole day blood glucose level.

  14. STRING BEAN JUICE DECREASES BLOOD GLUCOSE LEVEL PATIENTS WITH DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    Harmayetty Harmayetty

    2017-07-01

    Full Text Available Introduction: Type 2 diabetes mellitus is deficiency of insulin and caused by decreases of insulin receptor or bad quality of insulin. As a result, insulin hormone does not work effectively in blood glucose regulation. String bean juice contains thiamin and fiber may regulate blood glucose level. The aim of this study was to analyze the effect of string bean juice to decrease blood glucose level of patients with type 2 diabetes mellitus. Method: This study employed a quasy-experimental pre-post test control group design and purposive sampling.  The population were all type 2 diabetes mellitus patients in Puskesmas Pacar Keling Surabaya. Sample were 12 patients who met inclusion criteria. The independent variable was string bean juice and dependent variable was blood glucose level. Data were analyzed by using Paired T-test with significance level of α≤ 0.05 and Independent T-test with significant level of α≤0.05. Result: The results showed that string bean juice has an effect on decreasing blood glucose between pre test and post test for blood glucose with independent T-test is p=0.003. Analysis: In conclusion, string bean juice has an effect on blood glucose level in patients with type 2 diabetes mellitus. Discussion: The possible explanation for this findings is string bean juice contains two ingredients: thiamine and fiber. Thiamine helps support insulin receptors and glucose transporter in cells hence GLUT-4 could translocated to the cell membrane brought glucouse enter to the  intracellular compartment, that leads to blood glucouse level well regulated.  Dietary fiber reduces food transit time so slowing the glucose absorption. Therefore blood glucose level will be decreased.

  15. Replacement of glycaemic carbohydrates by inulin-type fructans from chicory (oligofructose, inulin) reduces the postprandial blood glucose and insulin response to foods: report of two double-blind, randomized, controlled trials.

    Science.gov (United States)

    Lightowler, Helen; Thondre, Sangeetha; Holz, Anja; Theis, Stephan

    2018-04-01

    Inulin-type fructans are recognized as prebiotic dietary fibres and classified as non-digestible carbohydrates that do not contribute to glycaemia. The aim of the present studies was to investigate the glycaemic response (GR) and insulinaemic response (IR) to foods in which sucrose was partially replaced by inulin or oligofructose from chicory. In a double-blind, randomized, controlled cross-over design, 40-42 healthy adults consumed a yogurt drink containing oligofructose or fruit jelly containing inulin and the respective full-sugar variants. Capillary blood glucose and insulin were measured in fasted participants and at 15, 30, 45, 60, 90, and 120 min after starting to drink/eat. For each test food, the incremental area under the curve (iAUC) for glucose and insulin was calculated and the GR and IR determined. Consumption of a yogurt drink with oligofructose which was 20% reduced in sugars significantly lowered the glycaemic response compared to the full-sugar reference (iAUC 120min 31.9 and 37.3 mmol/L/min, respectively; p inulin and containing 30% less sugars than the full-sugar variant likewise resulted in a significantly reduced blood glucose response (iAUC 120min 53.7 and 63.7 mmol/L/min, respectively; p inulin-type fructans (p inulin or oligofructose from chicory may be an effective strategy to reduce the postprandial blood glucose response to foods.

  16. Exponential increase in postprandial blood-glucose exposure with ...

    African Journals Online (AJOL)

    Background. Postprandial glucose excursions contribute significantly to average blood glucose, glycaemic variability and cardiovascular risk. Carbohydrate counting is a method of insulin dosing that balances carbohydrate load to insulin dose using a fixed ratio. Many patients and current insulin pumps calculate insulin ...

  17. The association between Western and Prudent dietary patterns and fasting blood glucose levels in type 2 diabetes and normal glucose metabolism in older Australian adults.

    Science.gov (United States)

    Walsh, Erin I; Jacka, Felice N; Butterworth, Peter; Anstey, Kaarin J; Cherbuin, Nicolas

    2017-06-01

    High blood glucose and type 2 diabetes are associated with a range of adverse health and cognitive outcomes. One factor that contributes to high blood glucose and type 2 diabetes is dietary intake. This study investigated the relationship between dietary patterns, fasting blood glucose and diabetes status in a sample of 209 participants aged 60-65. Blood plasma glucose was measured from venous blood samples. Individual Prudent and Western dietary patterns were estimated from a self-completed food frequency questionnaire. The relationship between dietary patterns, diabetes, and blood glucose was assessed via general linear model analyses controlling for age, sex, height, and total caloric intake. Results indicated that there was no association between Prudent diet and fasting blood glucose levels, or type 2 diabetes. In contrast, an individual in the upper tertile for Western dietary score had a significantly higher risk of having diabetes than an individual in the lower tertile for Western dietary score. However, there was no significant association between Western diet and fasting blood glucose. Western diet may be associated with type 2 diabetes through mechanisms beyond impacting blood plasma glucose directly. The fact that the association between Western diet and type 2 diabetes remained even when total caloric intake was controlled for highlights the need for policy and population health interventions targeting the reduction of unhealthy food consumption.

  18. Does self monitoring of blood glucose as opposed to urinalysis provide additional benefit in patients newly diagnosed with type 2 diabetes receiving structured education? The DESMOND SMBG randomised controlled trial protocol.

    Science.gov (United States)

    Dallosso, Helen M; Eborall, Helen C; Daly, Heather; Martin-Stacey, Lorraine; Speight, Jane; Realf, Kathryn; Carey, Marian E; Campbell, Michael J; Dixon, Simon; Khunti, Kamlesh; Davies, Melanie J; Heller, Simon

    2012-03-14

    The benefit of self-monitoring of blood glucose (SMBG) in people with type 2 diabetes on diet or oral agents other than sulphonylureas remains uncertain. Trials of interventions incorporating education about self-monitoring of blood glucose have reported mixed results. A recent systematic review concluded that SMBG was not cost-effective. However, what was unclear was whether a cheaper method of self-monitoring (such as urine glucose monitoring) could produce comparable benefit and patient acceptability for less cost. The DESMOND SMBG trial is comparing two monitoring strategies (blood glucose monitoring and urine testing) over 18 months when incorporated into a comprehensive self-management structured education programme. It is a multi-site cluster randomised controlled trial, conducted across 8 sites (7 primary care trusts) in England, UK involving individuals with newly diagnosed Type 2 diabetes.The trial has 80% power to demonstrate equivalence in mean HbA1c (the primary end-point) at 18 months of within ± 0.5% assuming 20% drop out and 20% non-consent. Secondary end-points include blood pressure, lipids, body weight and psychosocial measures as well as a qualitative sub-study.Practices were randomised to one of two arms: participants attend a DESMOND programme incorporating a module on self-monitoring of either urine or blood glucose. The programme is delivered by accredited educators who received specific training about equipoise. Biomedical data are collected and psychosocial scales completed at baseline, and 6, 12, and 18 months post programme. Qualitative research with participants and educators will explore views and experiences of the trial and preferences for methods of monitoring. The DESMOND SMBG trial is designed to provide evidence to inform the debate about the value of self-monitoring of blood glucose in people with newly diagnosed type 2 diabetes. Strengths include a setting in primary care, a cluster design, a health economic analysis, a

  19. A meal replacement regimen improves blood glucose levels in prediabetic healthy individuals with impaired fasting glucose.

    Science.gov (United States)

    König, Daniel; Kookhan, Sadaf; Schaffner, Denise; Deibert, Peter; Berg, Aloys

    2014-01-01

    The aim of this study was to investigate the effect of a 6-wk intervention with either lifestyle intervention (increased physical activity and a low-calorie diet) or a meal replacement regimen on glycemic control in patients who are prediabetic and have impaired fasting glucose. Forty-two overweight or obese men and women (age 54 ± 8 y; weight 95.1 ± 11.9 kg; body mass index [BMI] 32.8 ± 2.89 kg/m(2)) were included in this randomized controlled clinical trial. Patients in the lifestyle group (LS; n = 14) received dietary counseling sessions (fat-restricted low-calorie diet) and instructions on how to increase physical activity. Patients in the meal replacement group (MR; n = 28) were instructed to replace two daily meals with a low-calorie, high soy-protein drink with a low glycemic index. Both interventions resulted in a significant decrease in body weight and BMI, although the reduction was more pronounced (P meal replacement is an effective intervention for rapid improvement of elevated fasting glucose and increased insulin concentrations, these being important biomarkers of the prediabetic state. The 6-wk intervention has shown that the effect of meal replacement on fasting blood glucose was comparable to the effect of lifestyle intervention. The alterations in BMI, insulin, and HOMA-IR were significantly more pronounced following the meal replacement regimen. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Energy Technology Data Exchange (ETDEWEB)

    Meshram, N. D., E-mail: meshramnileshsd@gmail.com [Mathuradas Mohota College of Sciences, Nagpur-440009 (India); Dahikar, P. B., E-mail: pbdahikar@rediffmail.com [Kamla Nehru Mahavidyalaya, Sakkardara Square, Nagpur-440009 (India)

    2014-10-15

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  1. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    Science.gov (United States)

    Meshram, N. D.; Dahikar, P. B.

    2014-10-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current "finger-stick" methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively..

  2. Application of optical lens of a CD writer for detecting the blood glucose semi-invasively

    International Nuclear Information System (INIS)

    Meshram, N. D.; Dahikar, P. B.

    2014-01-01

    Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements more convenient. Currently over 100 small companies and universities are working to develop noninvasive or minimally invasive glucose sensing technologies, and optical methods play a large role in these efforts. It has become overwhelmingly clear that frequent monitoring and tight control of blood sugar levels are requisite for effective management of Diabetes mellitus and reduction of the complications associated with this disease. The pain and trouble associated with current “finger-stick” methods for blood glucose monitoring result in decreased patient compliance and a failure to control blood sugar levels. Thus, the development of a convenient noninvasive blood glucose monitor holds the potential to significantly reduce the morbidity and mortality associated with Diabetes. A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on photodiode based laser operating at 632.8 nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.

  3. Advances in Patient Self-Monitoring of Blood Glucose.

    Science.gov (United States)

    Pfützner, Andreas

    2015-11-29

    In 2 articles of the present issue, Bendini et al report about performance results obtained with 2 blood glucose monitoring systems of the Contour Next platform. Using several analysis methods, the authors demonstrate a very high accuracy, which meets all actual regulatory performance criteria. With consistent MARD results blood glucose meters during the Past 2 decades, starting with an MARD of 12-15% at the end of the past century and reaching an excellent accuracy < 5% today. © 2015 Diabetes Technology Society.

  4. EFFECT OF SAPPAN WOOD (Caesalpinnia sappan L EXTRACT ON BLOOD GLUCOSE LEVEL IN WHITE RATS

    Directory of Open Access Journals (Sweden)

    Saefudin Saefudin

    2016-05-01

    Full Text Available Sappan wood or kayu secang (Caesalpinia sappan L. was reported of having medicinal properties, such as natural antioxidant, relieve vomiting of blood, and mix of ingredients for malaria drugs. The research was conducted to study the influence of ethanol extract from sappan wood on blood glucose level of white rats. The study of the blood glucose level in rats was carried out by using glucose tolerance method. It was measured by Refloluxs (Accutrend GC with Chloropropamide 50 mg/200 g BW (Body weight as positive control. The ethanol extracts were used in various concentrations 10, 20, 30, 40 and 50 mg/200 g BW per-oral and was observed every hour, beginning one hour before to 7 hours after the extract being administered. The results showed that treatment of ethanol extract of sappan wood by administer doses gave remarkable effect on the blood glucose level in white rat. It reduced the glucose level in the blood compared to the negative and positive control. Treatment of dose 30 mg/200 g BW gave similar effect to positive controls, while a dose of 50 mg/200 g BW gave lower blood glucose level (93 mg/dl than the positive controls.

  5. Corticosterone and exogenous glucose alter blood glucose levels, neurotoxicity, and vascular toxicity produced by methamphetamine.

    Science.gov (United States)

    Bowyer, John F; Tranter, Karen M; Sarkar, Sumit; George, Nysia I; Hanig, Joseph P; Kelly, Kimberly A; Michalovicz, Lindsay T; Miller, Diane B; O'Callaghan, James P

    2017-10-01

    Our previous studies have raised the possibility that altered blood glucose levels may influence and/or be predictive of methamphetamine (METH) neurotoxicity. This study evaluated the effects of exogenous glucose and corticosterone (CORT) pretreatment alone or in combination with METH on blood glucose levels and the neural and vascular toxicity produced. METH exposure consisted of four sequential injections of 5, 7.5, 10, and 10 mg/kg (2 h between injections) D-METH. The three groups given METH in combination with saline, glucose (METH+Glucose), or CORT (METH+CORT) had significantly higher glucose levels compared to the corresponding treatment groups without METH except at 3 h after the last injection. At this last time point, the METH and METH+Glucose groups had lower levels than the non-METH groups, while the METH+CORT group did not. CORT alone or glucose alone did not significantly increase blood glucose. Mortality rates for the METH+CORT (40%) and METH+Glucose (44%) groups were substantially higher than the METH (glucose during METH exposure increases lethality and may exacerbate neurodegeneration. Neuroinflammation, specifically microglial activation, was associated with degenerating neurons in the parietal cortex and thalamus after METH exposure. The activated microglia in the parietal cortex were surrounding vasculature in most cases and the extent of microglial activation was exacerbated by CORT pretreatment. Our findings show that acute CORT exposure and elevated blood glucose levels can exacerbate METH-induced vascular damage, neuroinflammation, neurodegeneration and lethality. Cover Image for this issue: doi. 10.1111/jnc.13819. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  6. Glucometer as a chairside device to assess blood glucose in periodontal patients

    Directory of Open Access Journals (Sweden)

    G N Bala Raghavendra

    2010-01-01

    Full Text Available Background: Diabetes mellitus is a common finding in the medical history of patients receiving treatment for periodontal disease. The incidence of diabetes is on the rise worldwide. Virtually, every dentist and especially the periodontist are likely to encounter an increasing number of undiagnosed diabetic patients. The conventional laboratory methods employed to detect blood glucose are time consuming and require elaborative equipment. The advent of blood glucose monitors allows the clinician to assess blood glucose at the chair side. Materials and Methods: The use of gingival capillary blood as a marker for blood glucose estimation using glucometer against the conventional laboratory method has been assessed in 60 diabetics and 70 controls. Results: The correlation between gingival and finger-stick blood was r = 0.996, P<0.001 in diabetics and controls. Correlation between gingival and laboratory method was r = 0.994, P<0.001 in cases and controls. Conclusion: The results suggest that capillary blood from the outer surface of gingiva provide an acceptable source for measuring blood glucose.

  7. Blood-Brain Glucose Transfer in Alzheimer's disease

    DEFF Research Database (Denmark)

    Gejl, Michael; Brock, Birgitte; Egefjord, Lærke

    2017-01-01

    There are fewer than normal glucose transporters at the blood-brain barrier (BBB) in Alzheimer's disease (AD). When reduced expression of transporters aggravates the symptoms of AD, the transporters become a potential target of therapy. The incretin hormone GLP-1 prevents the decline of cerebral...... metabolic rate for glucose (CMRglc) in AD, and GLP-1 may serve to raise transporter numbers. We hypothesized that the GLP-1 analog liraglutide would prevent the decline of CMRglc in AD by raising blood-brain glucose transfer, depending on the duration of disease. We randomized 38 patients with AD...

  8. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Science.gov (United States)

    Mortazavi, SMJ; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, AR

    2014-01-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test). To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors. PMID:25505778

  9. Replacing Insulin Glargine with Neutral Protamine Hagedorn (NPH) Insulin in a Subpopulation of Study Subjects in the Action to Control Cardiovascular Risk in Diabetes (ACCORD): Effects on Blood Glucose Levels, Hypoglycemia and Patient Satisfaction.

    Science.gov (United States)

    Berard, Lori; Cameron, Brett; Woo, Vincent; Stewart, John

    2015-08-01

    To ensure patient safety when replacing insulin glargine (IG) with neutral protamine Hagedorn (NPH) insulin and to determine differences in blood glucose control, frequency of hypoglycemia, insulin dosing, health resource utilization and quality of life between users of IG and NPH insulin. A single-site, open-label, randomized, 6-month comparative study of 66 patients from the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. Randomization was 1:1 to receive IG or NPH insulin. Data regarding blood glucose control, insulin dosage adjustment and recording of hypoglycemia episodes were obtained through telephone calls; office visits were conducted to measure weight, glycated hemoglobin, fasting plasma glucose and blood glucose profile. The Diabetes Treatment Satisfaction Questionnaire (DTSQ) was used to measure patients' satisfaction with their diabetes treatment. Rates of symptomatic hypoglycemia did not differ significantly between groups: 37.5±2.2 for the IG group and 31.1±2.1 for the NPH group. However, patients treated with NPH insulin had higher frequencies of severe hypoglycemia (6.1±0.9) compared with 2.7±0.6 for the IG group. A significant difference in changes in glycated hemoglobin (A1C) was observed between the groups: the mean ± standard error A1C decreases from baseline were -0.34%±0.11 for the IG group, vs -0.01%±0.10 for the NPH insulin group. The data obtained from the DTSQ showed greater treatment satisfaction in the IG group compared with the NPH insulin group. Switching from IG to NPH insulin resulted in more than double the rate of severe hypoglycemias and led to decreased metabolic control. Greater treatment satisfaction was observed with IG, compared with NPH insulin, as measured by change from baseline in the DTSQ scores. Copyright © 2015 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  10. Blood Glucose Test: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... about 4 screens]. Available from: http://americanpregnancy.org/prenatal-testing/glucose-tolerence-test/ Centers for Disease Control and Prevention [Internet]. Atlanta: U.S. Department of Health ...

  11. Determination of glucose levels using dried filter paper blood spots: new perspective in home monitoring

    OpenAIRE

    Ward, Laura Sterian; Novis, Renata Britto; Nascimento, Veridiana Toledo; Nóbrega, Miriam Siesler; Saad, Mário José Abdalla

    1996-01-01

    We present a method for the determination of blood glucose using dried filter paper blood spots.To validate this method, we compared our results using filter paper and simultaneously collected venous blood. We demonstrated that there is a linear relationship between the filter paper glucose levels and those determined in whole blood (r=0.98). There was no significant difference between the results of the two methods (p>0.05).This method is a cheap alternative which may improve the control of ...

  12. Determination of glucose levels using dried filter paper blood spots: new perspective in home monitoring

    Directory of Open Access Journals (Sweden)

    Laura Sterian Ward

    Full Text Available We present a method for the determination of blood glucose using dried filter paper blood spots.To validate this method, we compared our results using filter paper and simultaneously collected venous blood. We demonstrated that there is a linear relationship between the filter paper glucose levels and those determined in whole blood (r=0.98. There was no significant difference between the results of the two methods (p>0.05.This method is a cheap alternative which may improve the control of diabetes mellitus, and may also be very useful in the diagnosis of postprandial hypoglycemia and other special situations.

  13. blood glucose level in Bufo gutturalis (power)

    African Journals Online (AJOL)

    a larger study dealing with glucose homeostasis in the toad Bufo gutturalis. Seven groups of seven toads each were acclimatized to laboratory conditions for one month. During this period the toads were fed daily on live insects and were housed in a large laboratory terrarium in which the natural habitat was simulated as ...

  14. Relationship between blood glucose levels and muscle strength in ...

    African Journals Online (AJOL)

    The prevalence of diabetes is increasing worldwide. High blood glucose has been associated with loss of muscle strength and mass in the lower extremities. However, in African children, little is known about the association between handgrip strength, flexed arm hang or other measures of muscle strength with blood ...

  15. Fasting blood glucose and haemoglobin concentrations of healthy ...

    African Journals Online (AJOL)

    Menstruation is associated with loss of blood monthly in women of reproductive age. In some women this physiological phenomenon is also associated with some complaints such as menstrual pain, vomiting, and tiredness. We investigated the fasting blood glucose concentration and hemoglobin concentration before and ...

  16. Cerebrospinal fluid ionic regulation, cerebral blood flow, and glucose use during chronic metabolic alkalosis

    Energy Technology Data Exchange (ETDEWEB)

    Schroeck, H.K.; Kuschinsky, W. (Univ. of Bonn (Germany, F.R.))

    1989-10-01

    Chronic metabolic alkalosis was induced in rats by combining a low K+ diet with a 0.2 M NaHCO3 solution as drinking fluid for either 15 or 27 days. Local cerebral blood flow and local cerebral glucose utilization were measured in 31 different structures of the brain in conscious animals by means of the iodo-(14C)antipyrine and 2-(14C)deoxy-D-glucose method. The treatment induced moderate (15 days, base excess (BE) 16 mM) to severe (27 days, BE 25 mM) hypochloremic metabolic alkalosis and K+ depletion. During moderate metabolic alkalosis no change in cerebral glucose utilization and blood flow was detectable in most brain structures when compared with controls. Cerebrospinal fluid (CSF) K+ and H+ concentrations were significantly decreased. During severe hypochloremic alkalosis, cerebral blood flow was decreased by 19% and cerebral glucose utilization by 24% when compared with the control values. The decrease in cerebral blood flow during severe metabolic alkalosis is attributed mainly to the decreased cerebral metabolism and to a lesser extent to a further decrease of the CSF H+ concentration. CSF K+ concentration was not further decreased. The results show an unaltered cerebral blood flow and glucose utilization together with a decrease in CSF H+ and K+ concentrations at moderate metabolic alkalosis and a decrease in cerebral blood flow and glucose utilization together with a further decreased CSF H+ concentration at severe metabolic alkalosis.

  17. The effect of an instant hand sanitizer on blood glucose monitoring results.

    Science.gov (United States)

    Mahoney, John J; Ellison, John M; Glaeser, Danielle; Price, David

    2011-11-01

    People with diabetes mellitus are instructed to clean their skin prior to self-monitoring of blood glucose to remove any dirt or food residue that might affect the reading. Alcohol-based hand sanitizers have become popular when soap and water are not available. The aim of this study was to determine whether a hand sanitizer is compatible with glucose meter testing and effective for the removal of exogenous glucose. We enrolled 34 nonfasting subjects [14 male/20 female, mean ages 45 (standard deviation, 9.4)] years, 2 with diagnosed diabetes/32 without known diabetes]. Laboratory personnel prepared four separate fingers on one hand of each subject by (1) cleaning the second finger with soap and water and towel drying (i.e., control finger), (2) cleaning the third finger with an alcohol-based hand sanitizer, (3) coating the fourth finger with cola and allowing it to air dry, and (4) coating the fifth finger with cola and then cleaning it with the instant hand sanitizer after the cola had dried. Finger sticks were performed on each prepared finger and blood glucose was measured. Several in vitro studies were also performed to investigate the effectiveness of the hand sanitizer for removal of exogenous glucose.z Mean blood glucose values from fingers cleaned with instant hand sanitizer did not differ significantly from the control finger (p = .07 and .08, respectively) and resulted in 100% accurate results. Blood glucose data from the fourth (cola-coated) finger were substantially higher on average compared with the other finger conditions, but glucose data from the fifth finger (cola-coated then cleaned with hand sanitizer) was similar to the control finger. The data from in vitro experiments showed that the hand sanitizer did not adversely affect glucose meter results, but when an exogenous glucose interference was present, the effectiveness of the hand sanitizer on glucose bias (range: 6% to 212%) depended on the surface area and degree of dilution. In our study

  18. Pre-germinated brown rice reduced both blood glucose concentration and body weight in Vietnamese women with impaired glucose tolerance.

    Science.gov (United States)

    Bui, Thi Nhung; Le, Thi Hop; Nguyen, Do Huy; Tran, Quang Binh; Nguyen, Thi Lam; Le, Danh Tuyen; Nguyen, Do Van Anh; Vu, Anh Linh; Aoto, Hiromichi; Okuhara, Yasuhide; Ito, Yukihiko; Yamamoto, Shigeru; Kise, Mitsuo

    2014-01-01

    We have reported that newly diagnosed type 2 diabetes mellitus (DM) patients in Vietnam have a low body mass index (BMI) of around 23 and that the major factor for this is high white rice (WR) intake. Brown rice (BR) is known to be beneficial in the control of blood glucose levels; however, it has the property of unpleasant palatability. Pre-germinated brown rice (PGBR) is slightly germinated by soaking BR in water as this reduces the hardness of BR and makes it easier to eat. This study was designed to evaluate the effect of a 4-mo PGBR administration on various parameters in Vietnamese women aged 45-65 y with impaired glucose tolerance (IGT). Sixty subjects were divided into a WR or PGBR group. For the first 2 wk, WR was replaced by 50% PGBR, then for 2 wk by 75% PGBR and from the second month 100%. Before the beginning of the study and at the end of the study, 1) anthropometric measurements, 2) a nutrition survey for 3 nonconsecutive days by the 24 h recall method and 3) blood biochemical examinations were conducted. Fasting plasma concentrations of glucose and lipids and the obesity-related measurements and blood pressure were favorably improved only in the PGBR diet group. The present results suggest that replacing WR with PGBR for 4 mo may be useful in controlling body weight as well as blood glucose and lipid levels in Vietnamese women with IGT.

  19. Comparison of a human portable blood glucose meter, veterinary portable blood glucose meter, and automated chemistry analyzer for measurement of blood glucose concentrations in dogs.

    Science.gov (United States)

    Johnson, Beth M; Fry, Michael M; Flatland, Bente; Kirk, Claudia A

    2009-12-01

    To compare blood glucose concentrations measured with 2 portable blood glucose meters (PBGMs) validated for use in dogs (PBGM-D) and humans (PBGM-H) and an automated chemistry analyzer. Validation study. 92 samples of fresh whole blood and plasma from 83 dogs with various diseases. Each PBGM was used to measure whole blood glucose concentration, and the automated analyzer was used to measure plasma glucose concentration. Passing-Bablok linear regression and Bland-Altman plots were used to determine correlations and bias between the PBGMs and the automated analyzer. Calculated acceptability limits based on combined inherent instrument imprecision were used with Bland-Altman plots to determine agreement. Clinical relevance was assessed via error grid analysis. Although correlation between results of both PBGMs and the standard analyzer was > 0.90, disagreement was greater than could be explained by instrument imprecision alone. Mean difference between PBGM-H and chemistry-analyzer values was -15.8 mg/dL. Mean difference between PBGM-D and chemistry-analyzer values was 2.4 mg/dL. Linear regression analysis revealed proportional bias of PBGM-H (greater disagreement at higher glucose concentrations); no proportional bias was detected for PBGM-D. No constant bias was detected for either PBGM. Error grid analysis revealed all measurements from both PBGMs were within zones without an anticipated effect on clinical outcome. Neither PBGM had exact agreement with the automated analyzer; however, the disagreement detected did not have serious clinical consequences. Our findings stressed the importance of using the same device for monitoring trends in dogs and using instrument-specific reference ranges.

  20. Institutional point-of-care glucometer identifies population trends in blood glucose associated with war.

    Science.gov (United States)

    Boaz, Mona; Matas, Zipora; Chaimy, Tova; Landau, Zohar; Bar Dayan, Yosefa; Berlovitz, Yitzhak; Wainstein, Julio

    2013-11-01

    Acute physiological stress has been shown to impair glucose homeostasis. War is a period of acute psychological stress, and its effect on glucose control is unknown. In this study random point-of-care (POC) glucose levels were measured using an automated, institutional glucometer in hospitalized adult patients prior to versus during the Israeli Pillar of Defense campaign (November 7-10, 2012). Random POC glucose values measured with the institutional blood glucose monitoring system were obtained 1 week prior to the Pillar of Defense campaign (November 7-10, 2012) and compared with values to those obtained during the first 4 days of the war (November 14-17, 2012). In total, 3,573 POC glucose measures were included: 1,865 during the pre-war period and 1,708 during the campaign. POC glucose measures were significantly higher during the war compared with the week preceding the war: 9.7±4.7 versus 9.3±4.2 mmol/L (P=0.02). In a general linear model, period (pre-war vs. during war) persisted as a significant predictor of POC glucose even after controlling for age, sex, and department type (internal medicine vs. surgical). Acute stress, such as a wartime situation, is associated with a significant increase in random blood glucose values in a population of hospitalized adults. Long-term follow-up of the individuals hospitalized during these two periods can reveal differences in morbidity and mortality trends.

  1. Chronotopic and blood pressure response to oral glucose load in chagas' disease

    Directory of Open Access Journals (Sweden)

    Maria Elena Guariento

    Full Text Available Cardiac chronotropic and pressor responses after an oral load of glucose were assessed in sixteen Chagasic subjects and 28 controls by means of blood pressure and pulse rate measurements. Cardiovascular response was correlated with serum insulin and glucose levels. The experiment identified a subgroup of Chagasic subjects (n=8 with a hypoinsulinemic behavior presenting less chronotropic and pressor responses than controls. This may indicate a lower insulin activity and/or an early Autonomic Nervous System dysfunction in this subgroup.

  2. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  3. [A blood glucose slide chart for improving diabetes patient education].

    Science.gov (United States)

    Potteau, Marie-Hélène

    2015-03-01

    A blood glucose slide chart has been developed in order to help patients with type 2 diabetes who do not speak French or who have comprehension difficulties. Combined with pictograms to help patients visualise the action they need to take depending on the recorded glucose level, it constitutes a therapeutic education tool which can be useful on a day-to-day basis both for patients as well as caregivers.

  4. Repeated Plyometric Exercise Attenuates Blood Glucose in Healthy Adults.

    Science.gov (United States)

    Barillas, Saldiam R; Watkins, Casey M; Wong, Megan A; Dobbs, Ian J; Archer, David C; Munger, Cameron N; Galpin, Andrew J; Coburn, Jared W; Brown, Lee E

    2017-01-01

    Plyometric exercise is popular in commercial exercise programs aiming to maximize energy expenditure for weight loss. However, the effect of plyometric exercise on blood glucose is unknown. The purpose of this study was to investigate the effect of relatively high intensity plyometric exercise on blood glucose. Thirteen subjects (6 females age= 21.8 ± 1.0 yrs.; height= 163.7 ± 7.8 cm; mass= 60.8 ± 6.7 kg and 7 males age= 22.0 ± 2.6 yrs.; height= 182.3 ± 3.6 cm; mass= 87.4 ± 12.5 kg) volunteered to participate. Subjects completed two random conditions on two separate days, consisting of either five sets of 10 maximal effort countermovement squat jumps (SJ) with 50 seconds' rest between sets or quiet sitting (SIT) for the time equated to the SJ duration (~4min). Immediately after each condition, subjects drank 75g of anhydrous glucose (CHO) in 100ml of water. Blood glucose measurements were taken via finger prick pre and immediately post SJ or SIT, and 5, 15, 30, and 60 min post. A 2×6 (condition × time) ANOVA revealed a significant interaction where SJ blood glucose was lower at 15 (114.0 ± 14.6 mg/dl) and 30 (142.1 ± 22.5 mg/dl) min compared to SIT (15min 130.8 ± 14.0 mg/dl and 30min 159.3 ± 21.0 mg/dl). The current plyometric protocol attenuated CHO-induced blood glucose at 15 and 30 min. This may be due to increased physiological stress applied to the muscles, thus increasing muscular glucose uptake.

  5. Blood sugar control in the intensive care unit: time to relook

    African Journals Online (AJOL)

    by a blood-glucose level exceeding the normal fasting level of. 5.5 mmol/l is common during critical ... normal, fasting blood levels associated with lowest risk of death. Intensive versus conventional glucose ... confirm its benefits in the implementation of tight glucose control policies in the ICU. Key words: blood glucose, ...

  6. Lower fasting blood glucose in neurofibromatosis type 1

    Science.gov (United States)

    Martins, Aline Stangherlin; Jansen, Ann Kristine; Rodrigues, Luiz Oswaldo Carneiro; Matos, Camila Maria; Souza, Marcio Leandro Ribeiro; de Souza, Juliana Ferreira; Diniz, Maria de Fátima Haueisen Sander; Barreto, Sandhi Maria; Diniz, Leonardo Mauricio; de Rezende, Nilton Alves; Riccardi, Vincent Michael

    2015-01-01

    Studies indicate a lower occurrence of diabetes mellitus (DM) in patients with neurofibromatosis type 1 (NF1). Fasting blood glucose (FBG) level is the main criterion used to diagnose DM and glucose intolerance. Therefore, this study compared FBG level between adults with NF1 and non-NF1 controls. We selected clinical records of 57 out of 701 individuals attending the Neurofibromatosis Outpatient Reference Center of the Clinics Hospital of the Federal University of Minas Gerais in Brazil. The selected patients with NF1 were matched to non-NF1 controls selected from the Brazilian Longitudinal Study of Adult Health according to sex, age (range, 35–74 years) and BMI at a ratio of 1:3. In both groups, individuals with DM were excluded. Median FBG level in the NF1 group (86 mg/dl (range, 56–127 mg/dl)) was lower than that in the non-NF1 control group (102 mg/dl (range, 85–146 mg/dl)) (P<0.001). Prevalence of FBG level ≥100 mg/dl in the NF1 group (16%) was lower than that in the non-NF1 control group (63%) (P<0.05). The chance of a high FBG level was 89% lower in the NF1 group (odds ratio, 0.112; 95% CI, 0.067–0.188) (P<0.05). In conclusion, adults with NF1 showed a lower FBG level and a lower prevalence of high FBG level compared with non-NF1 controls. PMID:26631381

  7. The food and drug administration is now preparing to establish tighter performance requirements for blood glucose monitors.

    Science.gov (United States)

    Klonoff, David C

    2010-05-01

    On March 16 and 17, 2010, the Food and Drug Administration (FDA) presented a public meeting about blood glucose monitoring at the Gaithersberg Hilton Hotel. The meeting was intended to present expert opinions and solicit input from the public about whether to develop new regulatory policies for blood glucose monitors. The meeting was divided into three sections: (1) Clinical Accuracy Requirements for Blood Glucose Monitors, (2) Interferences and Limitations of Blood Glucose Monitors, and (3) Tight Glycemic Control. Many officials from the Center for Devices and Radiologic Health and the Office of In Vitro Diagnostic Devices, which are the parts of FDA that regulate approval of blood glucose monitors, either spoke on the agenda or attended in the audience. Approximately 300 people attended; they were mostly clinicians (such as adult endocrinologists, pediatric endocrinologists, internists, clinical chemists, intensivists, surgeons, nurses, and diabetes educators) or industry officials from companies involved in glucose monitoring, pharmaceutical products, data analysis, or regulatory consulting. (c) 2010 Diabetes Technology Society.

  8. [Relationship between blood glucose levels and salivary pH and buffering capacity in type II diabetes patients].

    Science.gov (United States)

    Elkafri, I H; Mashlah, A; Shaqifa, A

    2014-03-13

    This study was evaluated the relationship between blood glucose levels and salivary pH and buffering capacity in type II diabetic patients. The sample comprised 210 participants (age ranged 40-60 years). Based on fasting blood glucose levels the participants were divided into 3 groups: controls with normal blood glucose levels; diabetic patients with levels ≤ 200 mg/dL; and diabetic patients with levels > 200 mg/dL. Salivary pH and buffering capacity were determined in a sample of resting (non-stimulated) saliva taken from each participant. Salivary pH levels in diabetic patients with blood glucose levels > 200 mg/dL were lower than in the controls and diabetic patients with levels ≤ 200 mg/dL. Salivary pH levels were comparable in controls and diabetic patients with blood glucose levels ≤ 200 mg/dL. Salivary buffering capacity in the 3 groups was comparable.

  9. Effect of transmucosal corn syrup application on postoperative blood glucose concentrations in kittens.

    Science.gov (United States)

    Cornell, Heather N; Shaver, Stephanie L; Semick, Danielle N; Bradley, Nancy C; Kreisler, Rachael E

    2018-04-01

    Objectives The aim of the study was to determine the effect of a common clinical practice, the transmucosal (TM) application of corn syrup, on postoperative blood glucose concentrations in kittens. Methods This study was designed as a randomized controlled trial. Seventy-five kittens between the age of 8 and 16 weeks scheduled for surgical sterilization by gonadectomy at an animal shelter were enrolled. Kittens were randomly assigned to either a routine treatment group that received the shelter's typical postoperative application of corn syrup immediately following gonadectomy or to a control group that did not receive typical treatment. Three blood glucose measurements were obtained per kitten: baseline reading prior to preoperative examination, immediately postoperatively and 20 mins postoperatively. The median values of the 20 min postoperative blood glucose reading for the control and treatment groups were compared using the Wilcoxon rank-sum test. Results Postoperative application of corn syrup to the oral mucosa of kittens did not result in significant elevations in blood glucose compared with controls. No kitten was hypoglycemic (⩽60 mg/dl) at any point during the study. Conclusions and relevance TM application of corn syrup did not affect postoperative blood glucose concentrations in kittens. Protocols that use routine TM administration of corn syrup in kittens should be re-evaluated.

  10. How Effective is Swedish Massage on Blood Glucose Level in Children with Diabetes Mellitus?

    Directory of Open Access Journals (Sweden)

    Firoozeh Sajedi

    2011-09-01

    Full Text Available "nThis study was conducted to determine the effect of Swedish massage on blood glucose level in children with diabetes mellitus (DM. It was prospective randomized controlled trial study that conducted on 36 children, 6-12 years old with DM, recruited from a hospital in Qom City, Iran. The children were randomly assigned to intervention and control groups. Swedish massage was performed 15 minutes, 3 times a week, for 3 months in intervention group. The blood glucose levels were evaluated immediately after every session of massage in two groups. The mean ages of children in the intervention (n=18 and control (n=18 groups were 9.05 ± 1.55 and 9.83 ±2.03 years respectively. There was statistically no significant difference in blood glucose levels before intervention between two groups (P=0.586, but the blood glucose levels were lower significantly in intervention group in comparison with control group after intervention (P<0.0001. Addition of Swedish massage to daily routines; exercise, diet and medication regimens, is an effective intervention to reduce blood glucose level in diabetic children.

  11. Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems

    Science.gov (United States)

    Teodorczyk, Maria; Cardosi, Marco; Setford, Steven

    2012-01-01

    Background Hematocrit (Hct) is a common interferent in test strips used by diabetes patients to self-monitor blood glucose (BG), resulting in measurement bias. Described is an electrochemical BG monitoring system (OneTouch® Verio™) that uses a cofacial sensor design, soluble enzyme chemistry, and multiphasic waveform to effectively correct for patient Hct, delivering an accurate reading for whole BG. Methods The test strip comprises thin-film gold and palladium electrodes arranged cofacially and spatially separated with a thin spacer. Soluble glucose-sensing reagents are located on the lower palladium electrode and are hydrated on sample application. Blood glucose is oxidized by flavoprotein glucose dehydrogenase, with electron transfer via (reduced) potassium ferrocyanide mediator at the palladium electrode. Hematocrit levels are estimated by measuring oxidation of mediator diffusion to the upper gold electrode during the first portion of the assay. The Hct-corrected glucose levels are determined by an on-meter algorithm. Results In performance testing of blood samples at five glucose levels (30–560 mg/dl) and five Hct levels (19–61%), using 12 test meters and 3 test strip lots, 100% of results (N = 2700) met International Organization for Standardization accuracy criteria (within ± 15 mg/dl and ± 20% of reference results at glucose levels of <75 and ≥75 mg/dl, respectively). Furthermore, 99.9% (2698 of 2700) of results were within ±12 mg/dl and ± 15% of reference values at glucose levels <80 and ≥80 mg/dl, respectively. Conclusions The technology used in this system provides accurate BG measurements that are insensitive to Hct levels across the range 20–60%. PMID:22768896

  12. Effects of MDMA on blood glucose levels and brain glucose metabolism

    Energy Technology Data Exchange (ETDEWEB)

    Soto-Montenegro, M.L.; Vaquero, J.J.; Garcia-Barreno, P.; Desco, M. [Hospital General Universitario Gregorio Maranon, Laboratorio de Imagen, Medicina Experimental, Madrid (Spain); Arango, C. [Hospital General Gregorio Maranon, Departamento de Psiquiatria, Madrid (Spain); Ricaurte, G. [Johns Hopkins University School of Medicine, Department of Neurology, Baltimore, MD (United States)

    2007-06-15

    This study was designed to assess changes in glucose metabolism in rats administered single or repeated doses of MDMA. Two different experiments were performed: (1) A single-dose study with four groups receiving 20 mg/kg, 40 mg/kg, saline or heat, and (2) a repeated-dose study with two groups receiving three doses, at intervals of 2 h, of 5 mg/kg or saline. Rats were imaged using a dedicated small-animal PET scanner 1 h after single-dose administration or 7 days after repeated doses. Glucose metabolism was measured in 12 cerebral regions of interest. Rectal temperature and blood glucose were monitored. Peak body temperature was reached 1 h after MDMA administration. Blood glucose levels decreased significantly after MDMA administration. In the single-dose experiment, brain glucose metabolism showed hyperactivation in cerebellum and hypo-activation in the hippocampus, amygdala and auditory cortex. In the repeated-dose experiment, brain glucose metabolism did not show any significant change at day 7. These results are the first to indicate that MDMA has the potential to produce significant hypoglycaemia. In addition, they show that MDMA alters glucose metabolism in components of the motor, limbic and somatosensory systems acutely but not on a long-term basis. (orig.)

  13. The impact of a novel peach gum-derived polysaccharide on postprandial blood glucose control in streptozotocin-induced diabetic mice.

    Science.gov (United States)

    Wang, Yuting; Lin, Dingbo; Wang, Xiaoli; Zhu, Wei; Ye, Junli; Li, Guohuai; Ma, Zhaocheng; Deng, Xiuxin

    2017-05-01

    Peach [Prunus persica (L.)] gum exudates are produced by the trunks and fruits in peach gummosis. Clinically, these exudates have been used to treat diabetes in China, though the molecular mechanism underlying remains unclear. In the current study, a novel peach gum-derived polysaccharide was isolated, designated as PGPSD, and its anti-diabetic effect was assessed in mice. This polysaccharide was composed of arabinose, xylose and galactose in the molar ratio of 5.98:1:3.55, with the average molecular weight at 1.00×10 6 Da. The animal study demonstrated that the PGPSD polysaccharide significantly lowered the postprandial blood glucose in streptozotocin-induced diabetic mice. Histology and immunohistochemistry results further confirmed that the application of PGPSD polysaccharide partially restored the pancreatic islets in diabetic mice, and enhanced the expression of pancreatic duodenal homeobox-1, insulin and hexokinase1. Collectively, the data suggested that the peach gum-derived polysaccharide had a meaningful potential as a non-insulin therapeutic compound in the treatment of diabetes. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Screening of Glucose-6-Phosphate Dehydrogenase Deficiency in Cord Blood

    Directory of Open Access Journals (Sweden)

    Can Acipayam

    2014-02-01

    Aim: Glucose-6-phosphate dehydrogenase deficiency is an important factor in etiology of pathologic neonatal jaundice. The aim of this study was to indicate the significance of screening glucose-6-phosphate dehydrogenase deficiency in the cord blood of neonates and the frequency of this deficiency in the etiology of neonatal hyperbilirubinemia. Material and Method: The study was performed consecutive 1015 neonates were included. Five hundred fifty six (54.8% of them were male and 459 (45.2% were female. The following parameters were recorded: Gender, birth weight, birth height, head circumference and gestational age. The glucose-6-phosphate dehydrogenase level of neonates were measured with quantitative method in cord blood. Also, hemoglobine, hematocrite, red blood cell count and blood group were measured. The following parameters were recorded in cases with jaundice: exchange transfusion, phototherapy, physiologic and pathologic jaundice, peak bilirubin day, maximum bilirubin level, total bilirubin level at the first day of jaundice, beginning time of jaundice. Results: Enzyme deficiency was detected in 133 (13.1% of neonates and 76 (57% of them were male, 57 (43% were female. Significant difference was detected in low glucose-6-phosphate dehydrogenase enzyme level with jaundice group for total bilirubin level at the first day of jaundice, maximum total bilirubin level and pathologic jaundice (p<0.05. Discussion: The ratio of glucose-6-phosphate dehydrogenase deficiency was found in Edirne in this study and this ratio was higher than other studies conducted in our country. For this reason, glucose-6-phosphate dehydrogenase enzyme level in cord blood of neonates should be measured routinely and high risk neonates should be followed up for hyperbilirubinemia and parents should be informed in our region.

  15. Umbilical cord blood glucose levels in full-term newborns

    Directory of Open Access Journals (Sweden)

    A. L. Karpova

    2014-01-01

    Full Text Available The purpose of the investigation was to determine the umbilical cord venous blood level of glucose in full-term newborns and its relationship to the mode of delivery. The investigation included 102 full-term newborn infants, including 33 and 69 babies born via cesar-ean and vaginal delivery, respectively. Umbilical cord serum glucose levels were determined by the glucose oxidase test using a Sap-phire-400 biochemical analyzer. In healthy full-term newborns, the mean umbilical cord blood glucose levels were 4,29±0,88 mmol/1 (minimum, 2,9 mmol/1 and maximum, 5,9 mmol/1. In the babies born via cesarean delivery, the umbilical cord blood concentration of glucose was ascertained to be significantly lower than in those born vaginally (3,84+0,71 mmol/1 versus 4,51+0,87 mmol/1; /><0,0001. Abdominal delivery can be apparently considered to be a risk factor for hypoglycemia in neonatal infants.

  16. Self-monitoring of blood glucose in tablet-treated type 2 diabetic patients (ZODIAC)

    NARCIS (Netherlands)

    Kleefstra, Nanno; Hortensius, J.; Logtenberg, Susan; Slingerland, R. J.; Groenier, K. H.; Houweling, S. T.; Gans, R. O. B.; van Ballegooie, E; Bilo, H. J. G.

    2010-01-01

    Background: Whether self-monitoring of blood glucose (SMBG) improves glycaemic control in patients with type 2 diabetes mellitus (T2DM) not using insulin is questionable. Our aim was to investigate the effects of SMBG in patients with T2DM who were in persistent moderate glycaemic control whilst not

  17. The relationship between serum cortisol, adrenaline, blood glucose ...

    African Journals Online (AJOL)

    Background: Stress is an extremely adaptive phenomenon in human beings and cortisol is a known stress hormone. Examination has been described as a naturalistic stressor capable of affecting human health. Objectives: To estimate the relationship between serum cortisol, adrenaline, fasting blood glucose (FBG) and ...

  18. Comparative effects of some medicinal plants on blood glucose ...

    African Journals Online (AJOL)

    The comparative effects of the chloroform extracts of the leaves of Psidium guajava (Myrtaceae), Anacardium occidentale (Anacardiaceae) and Eucalyptus globulus (Myrtaceae) and fruits of Xylopia aethiopica (Annonaceae) on blood glucose concentration and lipid levels of diabetic rats were investigated using standard ...

  19. Daidzin decreases blood glucose and lipid in streptozotocin ...

    African Journals Online (AJOL)

    Purpose: To investigate the ameliorative effect of daidzin (DZ) on diabetes in streptozotocin (STZ)- induced diabetic Institute of Cancer Research (ICR) mice, with a view to determining its usefulness in the treatment of diabetes. Methods: The effect of DZ (100, 200 and 400 mg/kg) on blood glucose was investigated in both ...

  20. Blood plasma glucose regulation in Wahlberg's epauletted fruit bat ...

    African Journals Online (AJOL)

    Frugivores feed on fruits and nectars that contain different types of sugars in different proportions, which provide these animals with energy. Wahlberg's epauletted fruit bat (Epomophorus wahlbergi) has a high glucose intake irrespective of sugar concentration of nectar. It is not known how these bats regulate their blood ...

  1. Effects of selenium yeast on blood glucose and antioxidant ...

    African Journals Online (AJOL)

    At the end of the study period, the animals were sacrificed and the serum samples were collected and evaluated for estimation of antioxidant enzymes such as superoxide dismutase (SOD), catalase (CAT) and glutathione peroxidase (GPx). The results showed a significant (P < 0.05) decrease in blood glucose level in the ...

  2. Haematological Indices, Blood glucose levels and lipid profile of rats ...

    African Journals Online (AJOL)

    This work was done as a part of safety assessment to determine the effects of Tartrazine E102 on some haematological indices, glucose levels and blood lipid profile in rats. An animal model was used as a basis for interpreting the situation in humans. Consequently, 40 albino rats were divided into 5 groups of 8 rats each.

  3. Effects of Watermelon ( Citrullus lanatus ) Seed on Blood Glucose ...

    African Journals Online (AJOL)

    Given the prevalence of diabetes worldwide, with its associated complications, this study is aimed at investigating the effect of citrullus lanatus seed extract on blood glucose concentration and electrolyte parameters. Citrullus lanatus is an antioxidant and has been shown to reduce oxidative stress (Khaki et al., 2013). Effects ...

  4. Adenosine deaminase activities and fasting blood glucose in obesity ...

    African Journals Online (AJOL)

    Background: A complex relationship seems to exist between adenosine deaminase (ADA) and insulin in obesity. Through its effect on adenosine, the enzyme can modulate the action of insulin and affect blood glucose while the administration of insulin is said to decrease the activities of the enzyme. Aim: To investigate the ...

  5. Blood-Brain Glucose Transfer in Alzheimer's disease

    DEFF Research Database (Denmark)

    Gejl, Michael; Brock, Birgitte; Egefjord, Lærke

    2017-01-01

    There are fewer than normal glucose transporters at the blood-brain barrier (BBB) in Alzheimer's disease (AD). When reduced expression of transporters aggravates the symptoms of AD, the transporters become a potential target of therapy. The incretin hormone GLP-1 prevents the decline of cerebral...

  6. Blood glucose response of normoglycemic adults fed breakfast ...

    African Journals Online (AJOL)

    Effect of high fibre leguminous products in breakfast porridges, made from Afzelia Africana (AA), Detarium microcarpum (DM), Sphenostylis stenocarpa (SS) and Zea mays on blood glucose level of humans was investigated in this study. The food items were processed into flour using African (Nigerian) traditional processing ...

  7. Effect of leaf extract of Pseudocedrela kotchyi on blood glucose ...

    African Journals Online (AJOL)

    The effect of leaf extract of Pseudocedrela kotchi (PK) on blood glucose of alloxan induced albino wistar rats was evaluated. Experimental animals received daily oral administration of extract of Pseudocedreala kotchi for 14 days. The effect of 200 mg/kg dose was studied during the treatment period. There was a significant ...

  8. Effect of extract of Abrs Precatorius on blood glucose concentration ...

    African Journals Online (AJOL)

    The effect of leaf extract of Abrus precatorius on blood glucose level of alloxan- induced diabetic albino wistar rats was evaluated. Experimental animals received daily oral administration of extract of Abrus precatorius for 14 days. The effect of 200 mg/kg dose was studied during the treatment period. There was a significant ...

  9. Data Mining Technologies for Blood Glucose and Diabetes Management

    NARCIS (Netherlands)

    Bellazzi, Riccardo; Abu-Hanna, Ameen

    2009-01-01

    Data mining is the process of selecting, exploring, and modeling large amounts of data to discover unknown patterns or relationships useful to the data analyst. This article describes applications of data mining for the analysis of blood glucose and diabetes mellitus data. The diabetes management

  10. Predictors of Daily Blood Glucose Monitoring in Appalachian Ohio

    Science.gov (United States)

    Raffle, Holly; Ware, Lezlee J.; Ruhil, Anirudh V. S.; Hamel-Lambert, Jane; Denham, Sharon A.

    2012-01-01

    Objective: To determine factors contributing to successful diabetes self-management in Appalachia, as evidenced by daily blood glucose monitoring. Methods: A telephone survey (N = 3841) was conducted to assess health status and health care access. The current investigation is limited to the subset of this sample who report having diabetes (N =…

  11. Variations of blood glucose in cancer patients during chemotherapy ...

    African Journals Online (AJOL)

    Purpose: The aim of this study was to analyze the blood glucose (BG) variations in cancer patients during chemotherapy according to tumor types and chemotherapeutic regimens. Materials and Methods: Patients were examined from the Department of Medical Oncology of Cancer Hospital and Institute, Chinese Academy ...

  12. Reliability of bedside blood glucose estimating methods in detecting ...

    African Journals Online (AJOL)

    Background: Hypoglycaemia occurs in many disease states common in the tropics. Facilities and skilled manpower required for laboratory blood glucose measurement are not always available in health facilities in developing countries. Objective: The study was carried out to determine the validity of bedside methods of ...

  13. Blood glucose lowering activity of five Nigerian medicinal plants in ...

    African Journals Online (AJOL)

    The blood glucose lowering effects of the aqueous leaf extracts of Cassia alata, Acalypha torta and Breynia nivosa, and aqueous root extracts of Daniellia oliveri and Nauclea latifolia traditionally employed in Nigeria in the management of diabetes mellitus were compared in alloxan-induced diabetic Wistar rats. The same ...

  14. Participation in blood glucose test, knowledge and prevalence of ...

    African Journals Online (AJOL)

    Background: Diabetes mellitus causes great health complications which include cardiovascular diseases and nerve damage. Aim: To ascertain the participation in blood glucose test, knowledge of diabetes mellitus (DM) and prevalence of hyperglycemia among traders at New market, Enugu State. Methods: The study is a ...

  15. Variations of blood glucose in cancer patients during chemotherapy

    African Journals Online (AJOL)

    2016-05-23

    May 23, 2016 ... Purpose: The aim of this study was to analyze the blood glucose (BG) variations in cancer patients during chemotherapy ... Materials and Methods: Patients were examined from the Department of Medical Oncology of Cancer Hospital and .... 68 (LC, 20.5%), colon cancer 63 (CC, 19.0%), rectal cancer.

  16. Evaluation of portable blood glucose meters using canine and feline pooled blood samples.

    Science.gov (United States)

    Mori, A; Oda, H; Onozawa, E; Shono, S; Takahashi, T; Yamashita, S; Fujimoto, H; Sako, T

    2016-12-01

    This study evaluated the accuracy and reproducibility of a human portable blood glucose meter (PBGM) for canine and feline whole blood. Reference plasma glucose values (RPGV) were concurrently measured using glucose oxidation methods. Fifteen healthy dogs and 6 healthy cats were used for blood sampling. Blood glucose concentrations and hematocrits were adjusted using pooled blood samples for our targeted values. A positive correlation between the PBGM and RPGV was found for both dogs (y = 0.877, x = -24.38, r = 0.9982, n = 73) and cats (y = 1.048, x = -27.06, r = 0.9984, n = 69). Acceptable results were obtained in error grid analysis between PBGM and RPGV in both dogs and cats; 100% of these results were within zones A and B. Following ISO recommendations, a PBGM is considered accurate if 95% of the measurements are within ± 15 mg/dl of the RPGV when the glucose concentration is cats (39%, 27 of 69 cats). Blood samples with high hematocrits induced lower whole blood glucose values measured by the PBGM than RPGV under hypoglycemic, normoglycemic, and hyperglycemic conditions in both dogs and cats. Therefore, this device is not clinically useful in dogs and cats. New PBGMs which automatically compensate for the hematocrit should be developed in veterinary practice.

  17. Effect of decrease in both postprandial blood glucose (PBG) and fasting blood glucose (FBG) levels in normal beagle dogs with nateglinide enteric coated granules and immediate release tablets.

    Science.gov (United States)

    Makino, Chisato; Ninomiya, Nobutaka; Sakai, Hidetoshi; Orita, Haruo; Okano, Akira; Yabuki, Akira

    2006-04-01

    Nateglinide is a new quick action/short duration (QRSD) type of oral blood glucose regulator, and nateglinide immediate release tablets are used for patients with mild diabetes under the trade name of Fastic((R)) tablets. In this study, we attempted to determine if it was possible to control both post-prandial blood glucose level (PBG) and fasting blood glucose level (FBG) for moderate or severe diabetes through controlled release of nateglinide. Enteric coated granules were selected for the administration form for controlled release of nateglinide, and three types of enteric coated granules were prepared having dissolution pH values of 5.5, 6.5 and 7.2. The three types of enteric coated granules were each administered separately or the enteric coated granules having an dissolution pH of 6.5 were administered simultaneous to administration of nateglinide immediate release tablets to normal beagle dogs just before feeding followed by measurement of plasma nateglinide concentration, plasma insulin concentration and blood glucose level. In the case of administering enteric coated granules alone (nateglinide: 9 mg/kg), the absorption of nateglinide was confirmed to tend to be delayed as the dissolution pH increased. In the case of an dissolution pH of 5.5, decreases in both PBG and FBG were observed. In the case of dissolution pH values of 6.5 and 7.2, only decrease in FBG was observed. In case of nateglinide immediate release tablets (nateglinide: 9 mg/kg), only decrease in PBG was observed. Decreases in both PBG and FBG were observed in the case of simultaneous administration of dissolution pH 6.5 enteric coated granules and nateglinide immediate release tablets just before feeding (nateglinide: 90 mg/head+60 mg/head). A correlation was observed between plasma nateglinide concentrations and blood glucose levels. On the other hand, there were no correlations observed between changes in plasma insulin concentrations and blood glucose levels. In case of nateglinide

  18. Postprandial Blood Glucose Outweighs Fasting Blood Glucose and HbA1c in screening Coronary Heart Disease.

    Science.gov (United States)

    Jiang, Jingjing; Zhao, Lin; Lin, Liu; Gui, Minghui; Aleteng, Qiqige; Wu, Bingjie; Wang, Shanshan; Pan, Baishen; Ling, Yan; Gao, Xin

    2017-10-27

    The objective of the present study is to assess the performance of fasting blood glucose (FBG), postprandial blood glucose (PBG), and glycated hemoglobin (HbA1c) as screening for coronary heart disease (CHD) in an inpatient population undergoing coronary angiography. 1852 consecutive patients scheduled for coronary angiography were classified into Normal Glucose Tolerance (NGT), Impaired Glucose Regulation (IGR), and diabetes, based on FBG, PBG, and HbA1c. Correlations of Gensini score with glucose metabolism and insulin resistance were analyzed. The associations between glycemic variables and Gensini score or the presence of CHD were analyzed by multiple linear regression and logistic regression, respectively. CHD was diagnosed in 488, 622, and 414 patients with NGT, IGR, and diabetes, respectively. Gensini score was positively correlated with FBG (r = 0.09, p PBG (r = 0.20, p PBG and HbA1c were pooled altogether, only PBG persisted in its association with Gensini score and the prevalence of CHD. The severity of CHD was associated with glucose rather than insulin resistance in this Chinese population. PBG was optimally correlated with the presence and severity of CHD.

  19. Quality assessment of patients’ self-monitoring of blood glucose in community pharmacies

    Directory of Open Access Journals (Sweden)

    Kjome RL

    2010-03-01

    Full Text Available Objective: To evaluate diabetes patients’ self-monitoring of blood glucose using a community pharmacy-based quality assurance procedure, to investigate whether the procedure improved the quality of the patient performance of self monitoring of blood glucose, and to examine the opinions of the patients taking part in the study. Methods: The results of patient blood glucose measurements were compared to the results obtained with HemoCue Glucose 201+ by pharmacy employees in 16 Norwegian community pharmacies. Patient performance was monitored using an eight item checklist. Patients whose blood glucose measurements differed from pharmacy measurements by more than 20% were instructed in the correct use of their glucometer. The patients then re-measured their blood glucose. If the results were still outside the set limits, the control procedure was repeated with a new lot of glucometer strips, and then with a new glucometer. The patients returned for a follow-up visit after three months. Results: During the first visit, 5% of the 338 patients had measurements that deviated from pharmacy blood glucose values by more than 20% and user errors were observed for 50% of the patients. At the second visit, there was no significant change in the analytical quality of patient measurements, but the percentage of patients who made user errors had decreased to 29% (p < 0.001. Eighty-five percent of the patients reported that they used their blood glucose results to adjust medication, exercise or meals. Fifty-one percent of the patients reported a greater trust in their measurements after the second visit. Eighty percent of patients wished to have their measurements assessed yearly. Of these patients, 83% preferred to have the assessment done at the community pharmacy. Conclusion: A community pharmacy-based quality assessment procedure of patients’ self monitoring of blood glucose significantly reduced the number of user errors. The analytical quality of the

  20. Effects of exposure to malathion on blood glucose concentration: a meta-analysis.

    Science.gov (United States)

    Ramirez-Vargas, Marco Antonio; Flores-Alfaro, Eugenia; Uriostegui-Acosta, Mayrut; Alvarez-Fitz, Patricia; Parra-Rojas, Isela; Moreno-Godinez, Ma Elena

    2018-02-01

    Exposure to malathion (an organophosphate pesticide widely used around the world) has been associated with alterations in blood glucose concentration in animal models. However, the results are inconsistent. The aim of this meta-analysis was to evaluate whether malathion exposure can disturb the concentrations of blood glucose in exposed rats. We performed a literature search of online databases including PubMed, EBSCO, and Google Scholar and reviewed original articles that analyzed the relation between malathion exposure and glucose levels in animal models. The selection of articles was based on inclusion and exclusion criteria. The database search identified thirty-five possible articles, but only eight fulfilled our inclusion criteria, and these studies were included in the meta-analysis. The effect of malathion on blood glucose concentration showed a non-monotonic dose-response curve. In addition, pooled analysis showed that blood glucose concentrations were 3.3-fold higher in exposed rats than in the control group (95% CI, 2-5; Z = 3.9; p < 0.0001) in a random-effect model. This result suggested that alteration of glucose homeostasis is a possible mechanism of toxicity associated with exposure to malathion.

  1. Age, gender, insulin and blood glucose control status alter the risk of ischemic heart disease and stroke among elderly diabetic patients

    Directory of Open Access Journals (Sweden)

    Hattori Yoshiyuki

    2011-10-01

    Full Text Available Abstract Background We analyzed the effects of insulin therapy, age and gender on the risk of ischemic heart disease (IHD and cerebrovascular accident (CVA according to glycemic control. Methods and Results We performed a prospective cohort study (Japan Cholesterol and Diabetes Mellitus Study of type 2 diabetes patients (n = 4014 for 2 years. The primary endpoint was the onset of fatal/non-fatal IHD and/or CVA, which occurred at rates of 7.9 and 7.2 per 1000 person-years, respectively. We divided diabetic patients into four groups based on age (≤ 70 and > 70 and hemoglobin A1C levels (≤ 7.0 and > 7.0%. Multiple regression analysis revealed that IHD was associated with high systolic blood pressure and low HDL-C in patients under 70 years of age with fair glycemic control and was associated with low diastolic blood pressure in the older/fair group. Interestingly, insulin use was associated with IHD in the older/poor group (OR = 2.27, 95% CI = 1.11-5.89; p = 0.026 and was associated with CVA in the older/fair group (OR = 2.09, 95% CI = 1.06-4.25; p = 0.028. CVA was associated with lower HDL-C and longer duration of diabetes in younger/poor glycemic control group. Results by stepwise analysis were similar. Next, patients were divided into four groups based on gender and diabetic control(hemoglobinA1C 7.0%. Multiple regression analysis revealed that IHD was associated with high systolic blood pressure in male/fair glycemic control group, age in male/poor control group, and short duration of diabetic history in females in both glycemic control groups. Interestingly, insulin use was associated with IHD in the male/poor group(OR = 4.11, 95% CI = 1.22-8.12; p = 0.018 and with CVA in the female/poor group(OR = 3.26, 95% CI = 1.12-6.24; p = 0.02. CVA was associated with short duration of diabetes in both female groups. Conclusions IHD and CVA risks are affected by specific factors in diabetics, such as treatment, gender and age. Specifically, insulin

  2. Circulating Glucagon 1-61 Regulates Blood Glucose by Increasing Insulin Secretion and Hepatic Glucose Production

    DEFF Research Database (Denmark)

    Wewer Albrechtsen, Nicolai J.; Kuhre, Rune E.; Hornburg, Daniel

    2017-01-01

    that PG 1-61 dose-dependently increases levels of cAMP, through the glucagon receptor, and increases insulin secretion and protein levels of enzymes regulating glycogenolysis and gluconeogenesis. In rats, PG 1-61 increases blood glucose and plasma insulin and decreases plasma levels of amino acids in...

  3. Brain Glucose Metabolism Controls Hepatic Glucose and Lipid Production

    OpenAIRE

    Lam, Tony K.T.

    2007-01-01

    Brain glucose-sensing mechanisms are implicated in the regulation of feeding behavior and hypoglycemic-induced hormonal counter-regulation. This commentary discusses recent findings indicating that the brain senses glucose to regulate both hepatic glucose and lipid production.

  4. Clinical significance of determination of serum leptin, insulin levels and blood sugar in pregnant women with glucose metabolism disturbances

    International Nuclear Information System (INIS)

    Yu Suqing; Li Yusheng; Wang Lin; Chu Kaiqiu

    2006-01-01

    Objective: To investigate the changes of serum leptin, insulin levels and blood sugar contents in pregnant women with gestational glucose metabolism disturbances. Methods: Fasting and 3h after oral 50g glucose serum levels of leptin were measured with RIA in 36 pregnant women with glucose metabolism disturbances (gestational diabetes mellitus or gestational impaired glucose tolerance) and 34 controls. Also, fasting serum insulin levels (with CLIA) and blood sugar contents 1h after oral 50 glucose (with glucose oxidase method) were determined in all these subjects. Results: 1. Serum levels of leptin in pregnant women with glucose metabolism disturbances were 14.9 ± 4.3 μg/L (vs controls 9.8 ± 1.7 μg/L, P<0.01). 2. The serum levels of insulin and 1 h post - 50g glucose blood sugar contents in pregnant women with glucose metabolism disturbances were 12.9±4.3mU/L and 11.0±1.4mmol/L respectively, which were both significantly positively correlated with the serum leptin levels (r=0.835, r=0.758 respectively) (vs levels in controls: 8.45±3.0mU/L and 7.84±1.3mmol/L). Conclusion: Elevation of fasting serum levels of leptin was demonstrated in pregnant women with glucose metabolism disturbances and the level of leptin was positively correlated with that of insulin and blood sugar. (authors)

  5. Effects of 50 mg vildagliptin twice daily vs. 50 mg sitagliptin once daily on blood glucose fluctuations evaluated by long-term self-monitoring of blood glucose.

    Science.gov (United States)

    Nomoto, Hiroshi; Kimachi, Kimihiko; Miyoshi, Hideaki; Kameda, Hiraku; Cho, Kyu Yong; Nakamura, Akinobu; Nagai, So; Kondo, Takuma; Atsumi, Tatsuya

    2017-04-29

    To date, several clinical trials have compared differences in glucose fluctuation observed with dipeptidyl peptidase-4 inhibitor treatment in patients with type 2 diabetes mellitus. However, most patients were assessed for limited periods or during hospitalization. The aim of the present study was to evaluate the effects of switching from sitagliptin to vildagliptin, or vice versa, on 12-week glucose fluctuations using self-monitoring of blood glucose in the standard care setting. We conducted a multicenter, prospective, open-label controlled trial in Japanese patients with type 2 diabetes. Thirty-two patients were treated with vildagliptin (50 mg) twice daily or sitagliptin (50 mg) once daily and were allocated to one of two groups: vildagliptin treatment for 12 weeks before switching to sitagliptin for 12 weeks, or vice versa. Daily profiles of blood glucose were assessed several times during each treatment period, and the mean amplitude of glycemic excursions and M-value were calculated. Metabolic biomarkers such as hemoglobin A1c (HbA1c), glycated albumin, and 1,5-anhydroglucitol were also assessed. With vildagliptin treatment, mean amplitude of glycemic excursions was significantly improved compared with sitagliptin treatment (57.9 ± 22.2 vs. 68.9 ± 33.0 mg/dL; p=0.0045). M-value (p=0.019) and mean blood glucose (p=0.0021) were also lower with vildagliptin, as were HbA1c, glycated albumin, and 1,5-anhydroglucitol. There were no significant differences in other metabolic parameters evaluated. Reduction of daily blood glucose profile fluctuations by vildagliptin was superior to that of sitagliptin in Japanese patients with type 2 diabetes.

  6. Glucose predictability, blood capillary permeability, and glucose utilization rate in subcutaneous, skeletal muscle, and visceral fat tissues.

    Science.gov (United States)

    Koutny, Tomas

    2013-11-01

    This study suggests an approach for the comparison and evaluation of particular compartments with modest experimental setup costs. A glucose level prediction model was used to evaluate the compartment's glucose transport rate across the blood capillary membrane and the glucose utilization rate by the cells. The glucose levels of the blood, subcutaneous tissue, skeletal muscle tissue, and visceral fat were obtained in experiments conducted on hereditary hypertriglyceridemic rats. After the blood glucose level had undergone a rapid change, the experimenter attempted to reach a steady blood glucose level by manually correcting the glucose infusion rate and maintaining a constant insulin infusion rate. The interstitial fluid glucose levels of subcutaneous tissue, skeletal muscle tissue, and visceral fat were evaluated to determine the reaction delay compared with the change in the blood glucose level, the interstitial fluid glucose level predictability, the blood capillary permeability, the effect of the concentration gradient, and the glucose utilization rate. Based on these data, the glucose transport rate across the capillary membrane and the utilization rate in a particular tissue were determined. The rates obtained were successfully verified against positron emission tomography experiments. The subcutaneous tissue exhibits the lowest and the most predictable glucose utilization rate, whereas the skeletal muscle tissue has the greatest glucose utilization rate. In contrast, the visceral fat is the least predictable and has the shortest reaction delay compared with the change in the blood glucose level. The reaction delays obtained for the subcutaneous tissue and skeletal muscle tissue were found to be approximately equal using a metric based on the time required to reach half of the increase in the interstitial fluid glucose level. © 2013 Published by Elsevier Ltd.

  7. Overnight glucose control in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe

    2018-01-01

    This paper presents an individualized model predictive control (MPC) algorithm for overnight blood glucose stabilization in people with type 1 diabetes (T1D). The MPC formulation uses an asymmetric objective function that penalizes low glucose levels more heavily. We compute the model parameters...... in the MPC in a systematic way based on a priori available patient information. The model used by the MPC algorithm for filtering and prediction is an autoregressive integrated moving average with exogenous input (ARIMAX) model implemented as a linear state space model in innovation form. The control...

  8. Insulin overlapping in whole blood FTIR spectroscopy in blood glucose measurements

    Science.gov (United States)

    Romo-Cárdenas, G.; Sánchez-López, J. de D.; Luque, P. A.; Cosío-León, M.; Nieto-Hipólito, Juan I.; Vázquez-Briseño, Mabel

    For the last decade, several studies on mid-IR spectroscopy for blood glucose quantification have not considered the compounds involved in the glucose regulation mechanism, in which insulin plays an important role. This work shows how insulin overlaps in the same mid-IR region in which glucose is quantified. This optical absorption interference is an important factor to be considered for this type of studies, in the scope of whole blood modeling for spectroscopy applications and the possible use of computer based metrics.

  9. A Deep Learning Approach to Diabetic Blood Glucose Prediction

    Directory of Open Access Journals (Sweden)

    Hrushikesh N. Mhaskar

    2017-07-01

    Full Text Available We consider the question of 30-min prediction of blood glucose levels measured by continuous glucose monitoring devices, using clinical data. While most studies of this nature deal with one patient at a time, we take a certain percentage of patients in the data set as training data, and test on the remainder of the patients; i.e., the machine need not re-calibrate on the new patients in the data set. We demonstrate how deep learning can outperform shallow networks in this example. One novelty is to demonstrate how a parsimonious deep representation can be constructed using domain knowledge.

  10. Clinical results from a noninvasive blood glucose monitor

    Science.gov (United States)

    Blank, Thomas B.; Ruchti, Timothy L.; Lorenz, Alex D.; Monfre, Stephen L.; Makarewicz, M. R.; Mattu, Mutua; Hazen, Kevin

    2002-05-01

    Non-invasive blood glucose monitoring has long been proposed as a means for advancing the management of diabetes through increased measurement and control. The use of a near-infrared, NIR, spectroscopy based methodology for noninvasive monitoring has been pursued by a number of groups. The accuracy of the NIR measurement technology is limited by challenges related to the instrumentation, the heterogeneity and time-variant nature of skin tissue, and the complexity of the calibration methodology. In this work, we discuss results from a clinical study that targeted the evaluation of individual calibrations for each subject based on a series of controlled calibration visits. While the customization of the calibrations to individuals was intended to reduce model complexity, the extensive requirements for each individual set of calibration data were difficult to achieve and required several days of measurement. Through the careful selection of a small subset of data from all samples collected on the 138 study participants in a previous study, we have developed a methodology for applying a single standard calibration to multiple persons. The standard calibrations have been applied to a plurality of individuals and shown to be persistent over periods greater than 24 weeks.

  11. Comparison of breath gases, including acetone, with blood glucose and blood ketones in children and adolescents with type 1 diabetes.

    Science.gov (United States)

    Blaikie, Tom P J; Edge, Julie A; Hancock, Gus; Lunn, Daniel; Megson, Clare; Peverall, Rob; Richmond, Graham; Ritchie, Grant A D; Taylor, David

    2014-11-25

    Previous studies have suggested that breath gases may be related to simultaneous blood glucose and blood ketone levels in adults with type 2 and type 1 diabetes. The aims of this study were to investigate these relationships in children and young people with type 1 diabetes in order to assess the efficacy of a simple breath test as a non-invasive means of diabetes management. Gases were collected in breath bags and measurements were compared with capillary blood glucose and ketone levels taken at the same time on a single visit to a routine hospital clinic in 113 subjects (59 male, age 7 years 11 months-18 years 3 months) with type 1 diabetes. The patients were well-controlled with relatively low concentrations of the blood ketone measured (β hydroxybutyrate, 0-0.4 mmol l(-1)). Breath acetone levels were found to increase with blood β hydroxybutyrate levels and a significant relationship was found between the two (Spearman's rank correlation ρ = 0.364, p acetone (ρ = 0.16, p = 0.1), but led to the conclusion that single breath measurements of acetone do not provide a good measure of blood glucose levels in this cohort. This result suggests a potential to develop breath gas analysis to provide an alternative to blood testing for ketone measurement, for example to assist with the management of type 1 diabetes.

  12. Perspectives of patients with non-insulin-treated type 2 diabetes on self-monitoring of blood glucose: A qualitative study.

    Science.gov (United States)

    Chen, Chen-Mei; Hung, Li-Chen; Chen, Yang-Lin; Yeh, Mei Chang

    2018-04-01

    To explore experiences of self-monitoring of blood glucose among patients with non-insulin-treated type 2 diabetes. Self-monitoring of blood glucose is essential to diabetes care and facilitates glycaemic control. Patients' perspectives of self-monitoring of blood glucose have seldom been discussed in the literature, and engagement in self-monitoring of blood glucose is consistently low. The descriptive phenomenological method was used. Purposive sampling was conducted to recruit participants from the endocrinology departments of medical institutions in Taiwan based on the following criteria: (i) having a medical diagnosis of type 2 diabetes, (ii) not being treated with insulin, (iii) having engaged in self-monitoring of blood glucose at least once within the preceding 6 months, (iv) being at least 20 years old and (v) not having any major mental or cognitive disorders. Data were collected in outpatient consultation rooms, the participants' homes and other settings where the participants felt secure and comfortable. In-depth interviews were conducted to collect data from 16 patients with diabetes. The participants perceived that lifestyle affected blood glucose levels and did not know how to handle high or low blood glucose levels. Their willingness to continue self-monitoring of blood glucose depended on whether healthcare professionals checked or discussed their blood glucose levels with them. The patients' knowledge regarding blood glucose variation and healthcare professionals' attitudes affected the patients' self-monitoring of blood glucose behaviours. The empirical findings illustrated self-monitoring of blood glucose experiences and recommended that healthcare professionals' closely attend to patients' requirements and responses to diabetes and incorporate the self-monitoring of blood glucose into therapy plans. Healthcare professionals should reinforce patients' knowledge on appropriate responses to high and low blood glucose levels, intervene

  13. Meal-stimulated glucagon release is associated with postprandial blood glucose level and does not interfere with glycemic control in children and adolescents with new-onset type 1 diabetes

    DEFF Research Database (Denmark)

    Pörksen, Sven; Nielsen, Lotte B; Kaas, Anne

    2007-01-01

    completed the 12-month follow-up. SETTING: The study was conducted at pediatric outpatient clinics. MAIN OUTCOME MEASURES: We assessed residual beta-cell function (C-peptide), glycosylated hemoglobin (HbA(1c)), blood glucose, glucagon, and glucagon-like peptide-1 (GLP-1) release in response to a 90-min meal......CONTEXT: The role of glucagon in hyperglycemia in type 1 diabetes is unresolved, and in vitro studies suggest that increasing blood glucose might stimulate glucagon secretion. OBJECTIVE: Our objective was to investigate the relationship between postprandial glucose and glucagon level during...... stimulation (Boost) at 1, 6, and 12 months after diagnosis. RESULTS: Compound symmetric repeated-measurements models including all three visits showed that postprandial glucagon increased by 17% during follow-up (P = 0.001). Glucagon levels were highly associated with postprandial blood glucose levels because...

  14. Facilitated transport of glucose from blood to brain in man and the effect of moderate hypoglycaemia on cerebral glucose utilization

    International Nuclear Information System (INIS)

    Blomqvist, G.; Widen, L.; Hellstrand, E.; Gutniak, M.; Grill, V.

    1991-01-01

    The effect of steady-state moderate hypoglycaemia on human brain homeostasis has been studied with positron emission tomography using D-glucose 11 C(ul) as tracer. To rule out any effects of insulin, the plasma insulin concentration was maintained at the same level under normo- and hypoglycaemic conditions. Reduction of blood glucose by 55% increased the glucose clearance through the blood-brain barrier by 50% and reduced brain glucose consumption by 40%. Blood flow was not affected. The results are consistent with facilitated transport of glucose from blood to brain in humans. The maximal transport rate of glucose from blood to brain was found to be 62±19 (mean±SEM) μmol hg -1 min -1 , and the half-saturation constant was found to be 4.1±3.2 mM. (orig.)

  15. Effect of adding the novel fiber, PGX®, to commonly consumed foods on glycemic response, glycemic index and GRIP: a simple and effective strategy for reducing post prandial blood glucose levels - a randomized, controlled trial

    Directory of Open Access Journals (Sweden)

    Lyon Michael

    2010-11-01

    Full Text Available Abstract Background Reductions in postprandial glycemia have been demonstrated previously with the addition of the novel viscous polysaccharide (NVP, PolyGlycopleX® (PGX®, to an OGTT or white bread. This study explores whether these reductions are sustained when NVP is added to a range of commonly consumed foods or incorporated into a breakfast cereal. Methods Ten healthy subjects (4M, 6F; age 37.3 ± 3.6 y; BMI 23.8 ± 1.3 kg/m2, participated in an acute, randomized controlled trial. The glycemic response to cornflakes, rice, yogurt, and a frozen dinner with and without 5 g of NVP sprinkled onto the food was determined. In addition, 3 granolas with different levels of NVP and 3 control white breads and one white bread and milk were also consumed. All meals contained 50 g of available carbohydrate. Capillary blood samples were taken fasting and at 15, 30, 45, 60, 90 and 120 min after the start of the meal. The glycemic index (GI and the glycemic reduction index potential (GRIP were calculated. The blood glucose concentrations at each time and the iAUC values were subjected to repeated-measures analysis of variance (ANOVA examining for the effect of test meal. After demonstration of significant heterogeneity, differences between individual means was assessed using GLM ANOVA with Tukey test to adjust for multiple comparisons. Results Addition of NVP reduced blood glucose response irrespective of food or dose (p Conclusion Sprinkling or incorporation of NVP into a variety of different foods is highly effective in reducing postprandial glycemia and lowering the GI of a food. Clinical Trial registration NCT00935350.

  16. Effect of adding the novel fiber, PGX®, to commonly consumed foods on glycemic response, glycemic index and GRIP: a simple and effective strategy for reducing post prandial blood glucose levels--a randomized, controlled trial.

    Science.gov (United States)

    Jenkins, Alexandra L; Kacinik, Veronica; Lyon, Michael; Wolever, Thomas Ms

    2010-11-22

    Reductions in postprandial glycemia have been demonstrated previously with the addition of the novel viscous polysaccharide (NVP), PolyGlycopleX® (PGX®), to an OGTT or white bread. This study explores whether these reductions are sustained when NVP is added to a range of commonly consumed foods or incorporated into a breakfast cereal. Ten healthy subjects (4M, 6F; age 37.3 ± 3.6 y; BMI 23.8 ± 1.3 kg/m2), participated in an acute, randomized controlled trial. The glycemic response to cornflakes, rice, yogurt, and a frozen dinner with and without 5 g of NVP sprinkled onto the food was determined. In addition, 3 granolas with different levels of NVP and 3 control white breads and one white bread and milk were also consumed. All meals contained 50 g of available carbohydrate. Capillary blood samples were taken fasting and at 15, 30, 45, 60, 90 and 120 min after the start of the meal. The glycemic index (GI) and the glycemic reduction index potential (GRIP) were calculated. The blood glucose concentrations at each time and the iAUC values were subjected to repeated-measures analysis of variance (ANOVA) examining for the effect of test meal. After demonstration of significant heterogeneity, differences between individual means was assessed using GLM ANOVA with Tukey test to adjust for multiple comparisons. Addition of NVP reduced blood glucose response irrespective of food or dose (p granola, and granolas with 2.5 and 5 g of NVP were 64 ± 6, 33 ± 5, and 22 ± 3 respectively. GRIP was 6.8 ± 0.9 units per/g of NVP. Sprinkling or incorporation of NVP into a variety of different foods is highly effective in reducing postprandial glycemia and lowering the GI of a food. NCT00935350.

  17. Effect of adding the novel fiber, PGX®, to commonly consumed foods on glycemic response, glycemic index and GRIP: a simple and effective strategy for reducing post prandial blood glucose levels - a randomized, controlled trial

    Science.gov (United States)

    2010-01-01

    Background Reductions in postprandial glycemia have been demonstrated previously with the addition of the novel viscous polysaccharide (NVP), PolyGlycopleX® (PGX®), to an OGTT or white bread. This study explores whether these reductions are sustained when NVP is added to a range of commonly consumed foods or incorporated into a breakfast cereal. Methods Ten healthy subjects (4M, 6F; age 37.3 ± 3.6 y; BMI 23.8 ± 1.3 kg/m2), participated in an acute, randomized controlled trial. The glycemic response to cornflakes, rice, yogurt, and a frozen dinner with and without 5 g of NVP sprinkled onto the food was determined. In addition, 3 granolas with different levels of NVP and 3 control white breads and one white bread and milk were also consumed. All meals contained 50 g of available carbohydrate. Capillary blood samples were taken fasting and at 15, 30, 45, 60, 90 and 120 min after the start of the meal. The glycemic index (GI) and the glycemic reduction index potential (GRIP) were calculated. The blood glucose concentrations at each time and the iAUC values were subjected to repeated-measures analysis of variance (ANOVA) examining for the effect of test meal. After demonstration of significant heterogeneity, differences between individual means was assessed using GLM ANOVA with Tukey test to adjust for multiple comparisons. Results Addition of NVP reduced blood glucose response irrespective of food or dose (p granola, and granolas with 2.5 and 5 g of NVP were 64 ± 6, 33 ± 5, and 22 ± 3 respectively. GRIP was 6.8 ± 0.9 units per/g of NVP. Conclusion Sprinkling or incorporation of NVP into a variety of different foods is highly effective in reducing postprandial glycemia and lowering the GI of a food. Clinical Trial registration NCT00935350. PMID:21092221

  18. The Impact of Telemedicine Interventions Involving Routine Transmission of Blood Glucose Data with Clinician Feedback on Metabolic Control in Youth with Type 1 Diabetes: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Palmert MarkR

    2010-07-01

    Full Text Available Our objective was to determine the impact of telemedicine (TM interventions on the management of type 1 diabetes (T1DM in youth. We performed a systematic review of randomized trials that evaluated TM interventions involving transmission of blood glucose data followed by unsolicited scheduled clinician feedback. We found no apparent effect of the TM interventions on hemoglobin A1c (HbA1c, severe hypoglycemia, or diabetic ketoacidosis. The limited data available on patient satisfaction, quality of life, and cost also suggested no differences between groups. It is unlikely that TM interventions, as performed in the assessed studies, had a substantial effect on glycemic control or acute complications. However, it remains possible that there are other benefits of TM not adequately reported, that newer TM strategies may be more effective and that interventions may benefit subgroups of youth, such as those with the poor glycemic control, adolescents, or those living in remote areas.

  19. The Glucose-Insulin Control System

    DEFF Research Database (Denmark)

    Hallgreen, Christine Erikstrup; Korsgaard, Thomas Vagn; Hansen, RenéNormann N.

    2008-01-01

    are divided into smaller pieces and analyzed via several small biosimulation models that describe events in beta cells, liver, muscle and adipose tissue etc. In the glucose-sensing part, the beta cell are shown to have some characteristics of a classic PID controller, but with nonlinear properties....... Furthermore, the body has also glucose sensors in the intestine, the brain, the portal vein, and to some extent the liver, and they sense very different glucose concentrations. All sensors are incorporated in a dynamic network that is interconnected by both hormones and the nervous system. Regarding glucose...... is influenced by insulin. Another facet is that the control system has to cope with the complex traffic of metabolites inside cells and between organs on time-scales from minutes to months or more. The analysis is evaluated using setups called "virtual experiments", i.e. biosimulation models describing common...

  20. Comparison of blood glucose test strips in the detection of neonatal hypoglycaemia

    OpenAIRE

    Wilkins, B H; Kalra, D

    1982-01-01

    Blood glucose levels were estimated in 101 neonatal blood samples using three glucose test strip methods and the results compared with those from a laboratory. BM-test-glycemie 20-800 test strips and Reflotest-hypoglycemie test strips gave a rapid and reliable estimate of blood glucose level in the range 0-8 mmol/l (0-140 mg/100 ml). Dextrostix test strips tended to overestimate all blood glucose levels.

  1. Optimal glucose control in type 2 diabetes mellitus – a guide for the ...

    African Journals Online (AJOL)

    vascular complications. The family practitioner plays a significant role in the management of glycaemic control and thereby reducing the related morbidity and mortality. Monitoring of blood glucose control has become an integral part of disease ...

  2. Sleep Control, GPCRs, and Glucose Metabolism.

    Science.gov (United States)

    Tsuneki, Hiroshi; Sasaoka, Toshiyasu; Sakurai, Takeshi

    2016-09-01

    Modern lifestyles prolong daily activities into the nighttime, disrupting circadian rhythms, which may cause sleep disturbances. Sleep disturbances have been implicated in the dysregulation of blood glucose levels and reported to increase the risk of type 2 diabetes (T2D) and diabetic complications. Sleep disorders are treated using anti-insomnia drugs that target ionotropic and G protein-coupled receptors (GPCRs), including γ-aminobutyric acid (GABA) agonists, melatonin agonists, and orexin receptor antagonists. A deeper understanding of the effects of these medications on glucose metabolism and their underlying mechanisms of action is crucial for the treatment of diabetic patients with sleep disorders. In this review we focus on the beneficial impact of sleep on glucose metabolism and suggest a possible strategy for therapeutic intervention against sleep-related metabolic disorders. Copyright © 2016. Published by Elsevier Ltd.

  3. Application of chronic intravascular blood glucose sensor in dogs.

    Science.gov (United States)

    Armour, J C; Lucisano, J Y; McKean, B D; Gough, D A

    1990-12-01

    An intravenous glucose sensor was implanted in six dogs for 1-15 wk. The glucose sensor is a flexible cylinder, approximately 0.2 cm diam and 30 cm long, with a tip containing immobilized glucose oxidase and catalase coupled to a potentiostatic O2 sensor. The sensor and a similar O2 reference sensor were implanted in the superior vena cava near the entrance of the right atrium. The sensor response was conveyed externally either by a telemetry system implanted nearby, surgically accessed leads, or chronically maintained percutaneous leads. Summing over the six implants, there was a total implantation period of 333 days during which glucose sensors were functional on demand. The sensor response showed agreement with conventionally assayed blood samples after accounting for a response lag. Sensor response to glucose showed little change over the implant period. Biocompatibility, enzyme lifetime, O2 availability, O2 sensor stability, and biochemical interference were not limitations. Results demonstrated that this sensor can function effectively as an implant in dogs for a period of months and has the potential for long-term operation.

  4. The Period of Operation and Perioperative Blood Glucose ...

    African Journals Online (AJOL)

    Demographic data as well as duration of fast was obtained, blood glucose level was estimated by One touch glucometer (Life Scan Inc. USA) immediately after induction. The mean age of the children was 4.1±2.6 yr and the mean weight was 15.9±6.2 kg. The mean duration of preoperative fast was 13.1±4.2 h (5-23) h.

  5. Non-invasive Blood Glucose Quantification Using a Hybrid Sensor

    Directory of Open Access Journals (Sweden)

    Sundararajan JAYAPAL

    2009-02-01

    Full Text Available Diabetes Mellitus is a group of metabolic diseases characterized by high blood sugar (glucose levels which result from defects in insulin secretion. It is very important for the diabetics and normal people to have a correct blood glucose level. The HbA1c test is the most preferred test by renowned doctors for glucose quantification. But this test is an invasive one. At present, there are many available techniques for this purpose but these are mostly invasive or minimally non-invasive and most of these are under research. Among the different methods available, the photo acoustic (PA methods provide a reliable solution since the acoustical energy loss is much less compared to the optical or other techniques. Here a novel framework is presented for blood glucose level measurement using a combination of the HbA1c test and a PA method to get an absolutely consistent and precise, non-invasive technique. The setup uses a pulsed laser diode with pulse duration of 5-15 ns and at a repetition rate of 10 Hz as the source. The detector setup is based on the piezoelectric detection. It consists of a ring detector that includes two double ring sensors that are attached to the ring shaped module that can be worn around the finger. The major aim is to detect the photo acoustic signals from the glycated hemoglobin with the least possible error. The proposed monitoring system is designed with extreme consideration to precision and compatibility with the other computing devices. The results obtained in this research have been studied and analyzed by comparing these with those of in-vitro techniques like the HPLC. The comparison has been plotted and it shows a least error. The results also show a positive drive for using this concept as a basis for future extension in quantifying the other blood components.

  6. Evaluation of day-to-day variability of serial blood glucose concentration curves in diabetic dogs.

    Science.gov (United States)

    Fleeman, Linda M; Rand, Jacquie S

    2003-02-01

    To evaluate day-to-day variability of serial blood glucose concentration curves in dogs with diabetes mellitus. Prospective clinical study. 10 dogs with diabetes mellitus. Paired 12-hour serial blood glucose concentration curves performed during 2 consecutive days were obtained on 3 occasions from each dog. Dogs received the same dose of insulin and meal every 12 hours on both days. For each pair of curves, comparison was made between the results of days 1 and 2. Mean absolute difference (without regard to sign) between days 1 and 2 for each parameter was significantly > 0, disproving the hypothesis that there is minimal day-to-day variability of serial blood glucose concentration curves when insulin dose and meals are kept constant. Coefficient of variation of the absolute difference between days 1 and 2 for each parameter ranged from 68 to 103%. Evaluation of the paired curves led to an opposite recommendation for adjustment of the insulin dose on day 2, compared with day 1, on 27% of occasions. Disparity between dosage recommendations was more pronounced when glucose concentration nadir was dogs. Day-to-day variability of serial blood glucose concentration curves has important clinical implications, particularly in dogs with good glycemic control.

  7. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    Science.gov (United States)

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).

  8. Potassium Intake, Bioavailability, Hypertension, and Glucose Control

    Directory of Open Access Journals (Sweden)

    Michael S. Stone

    2016-07-01

    Full Text Available Potassium is an essential nutrient. It is the most abundant cation in intracellular fluid where it plays a key role in maintaining cell function. The gradient of potassium across the cell membrane determines cellular membrane potential, which is maintained in large part by the ubiquitous ion channel the sodium-potassium (Na+-K+ ATPase pump. Approximately 90% of potassium consumed (60–100 mEq is lost in the urine, with the other 10% excreted in the stool, and a very small amount lost in sweat. Little is known about the bioavailability of potassium, especially from dietary sources. Less is understood on how bioavailability may affect health outcomes. Hypertension (HTN is the leading cause of cardiovascular disease (CVD and a major financial burden ($50.6 billion to the US public health system, and has a significant impact on all-cause morbidity and mortality worldwide. The relationship between increased potassium supplementation and a decrease in HTN is relatively well understood, but the effect of increased potassium intake from dietary sources on blood pressure overall is less clear. In addition, treatment options for hypertensive individuals (e.g., thiazide diuretics may further compound chronic disease risk via impairments in potassium utilization and glucose control. Understanding potassium bioavailability from various sources may help to reveal how specific compounds and tissues influence potassium movement, and further the understanding of its role in health.

  9. Postprandial blood glucose and insulin responses to pre-germinated brown rice in healthy subjects.

    Science.gov (United States)

    Ito, Yukihiko; Mizukuchi, Aya; Kise, Mitsuo; Aoto, Hiromichi; Yamamoto, Shigeru; Yoshihara, Rie; Yokoyama, Jyunichi

    2005-08-01

    Effects of pre-germinated brown rice (PGBR) on postprandial blood glucose and insulin concentrations were compared with brown rice (BR) and white rice (WR) in two studies. In the first study, we investigated the time course of postprandial blood glucose and insulin concentrations after ingesting 25% (W/V) glucose solution, PGBR, BR or WR in 19 healthy young subjects. In the second study, dose-dependent effect of PGBR on the time course of postprandial blood glucose concentrations was compared among 4 different mixtures of PGBR and WR in 13 healthy young subjects. They were solely PGBR, 2/3 PGBR (PGBR: WR = 2 : 1), 1/3 PGBR (PGBR : WR = 1 : 2) and solely WR. Each sample was studied on a different day. The samples were selected randomly by the subjects. All the rice samples contained 50 g of available carbohydrates. The previous day the subjects ate the assigned dinner by 9:00 pm and then were allowed only water until the examination. The next morning, they ingested each test rice sample with 150 ml of water in 5-10 min. Blood was collected into capillary tubes from finger at 0, 30, 60, 90 and 120 min after the ingestion. The incremental areas under the curve (IAUC) of blood glucose concentrations (IAUC-Glc) for 120 min after the administration of PGBR and BR were lower than those after WR. In contrast the IAUC-Glc of BR and PGBR were not different (Study 1). The higher the ratio of PGBR/WR, the lower the glycemic index became (Study 2). These results suggest that intake of PGBR instead of WR is effective for the control of postprandial blood glucose concentration without increasing the insulin secretion.

  10. Effects of Cinnamomum zeylanicum (Ceylon cinnamon) on blood glucose and lipids in a diabetic and healthy rat model.

    Science.gov (United States)

    Ranasinghe, Priyanga; Perera, Sanja; Gunatilake, Mangala; Abeywardene, Eranga; Gunapala, Nuwan; Premakumara, Sirimal; Perera, Kamal; Lokuhetty, Dilani; Katulanda, Prasad

    2012-04-01

    To evaluate short- and long-term effects of Cinnamomum zeylanicum on food consumption, body weight, glycemic control, and lipids in healthy and diabetes-induced rats. The study was conducted in two phases (Phase I and Phase II), using Sprague-Dawley rats in four groups. Phase I evaluated acute effects on fasting blood glucose (FBG) (Groups 1 and 2) and on post-oral glucose (Groups 3 and 4) blood glucose. Groups 1 and 3 received distilled-water and Groups 2 and 4 received cinnamon-extracts. Phase II evaluated effects on food consumption, body weight, blood glucose, and lipids over 1 month. Group A (n = 8, distilled-water) and Group B (n = 8, cinnamon-extracts) were healthy rats, while Group C (n = 5, distilled-water) and Group D (n = 5, cinnamon-extracts) were diabetes-induced rats. Serum lipid profile and HbA1c were measured on D-0 and D-30. FBG, 2-h post-prandial blood glucose, body weight, and food consumption were measured on every fifth day. There was no significant difference in serial blood glucose values in cinnamon-treated group from time 0 (P > 0.05). Following oral glucose, the cinnamon group demonstrated a faster decline in blood glucose compared to controls (P cinnamon-extracts in FBG and 2-h post-prandial blood glucose from D0 to D30 was shown only in diabetes-induced rats. In cinnamon-extracts administered groups, total and LDL cholesterol levels were lower on D30 in both healthy and diabetes-induced animals (P < 0.001). C. zeylanicum lowered blood glucose, reduced food intake, and improved lipid parameters in diabetes-induced rats.

  11. Analytical Performance Evaluation of Infopia Element™ Auto-coding Blood Glucose Monitoring System for Self-Monitoring of Blood Glucose.

    Science.gov (United States)

    Park, Hae-Il; Lee, Seong-Su; Son, Jang-Won; Kwon, Hee-Sun; Kim, Sung Rae; Chae, Hyojin; Kim, Myungshin; Kim, Yonggoo; Yoo, Soonjib

    2016-11-01

    Element™ Auto-coding Blood Glucose Monitoring System (BGMS; Infopia Co., Ltd., Anyang-si, Korea) was developed for self-monitoring of blood glucose (SMBG). Precision, linearity, and interference were tested. Eighty-four capillary blood samples measured by Element™ BGMS were compared with central laboratory method (CLM) results in venous serum. Accuracy was evaluated using ISO 15197:2013 criteria. Coefficients of variation (CVs; mean) were 2.4% (44.2 mg/dl), 3.7% (100.6 mg/dl), and 2.1% (259.8 mg/dl). Linearity was shown at concentrations 39.25-456.25 mg/l (y = 0.989 + 0.984x, SE = 17.63). Up to 15 mg/dl of galactose, ascorbic acid, and acetaminophen, interference > 10.4% was not observed. Element™ BGMS glucose was higher than CLM levels by 3.2 mg/dl (at 200 mg/dl) to 8.2 mg/dl (at 100 mg/dl). The minimum specification for bias (3.3%) was met at 140 and 200 mg/l glucose. In the Clarke and consensus error grids, 100% of specimens were within zone A and B. For Element™ BGMS values, 92.9% (78/84) to 94.0% (79/84) were within a 15 mg/dl ( 100 mg/dl) of the average CLM value. Element™ BGMS was considered an appropriate SMBG for home use; however, the positive bias at low-to-mid glucose levels requires further improvement. © 2016 Wiley Periodicals, Inc.

  12. Glycolysis Controls Plasma Membrane Glucose Sensors To Promote Glucose Signaling in Yeasts

    Science.gov (United States)

    Cairey-Remonnay, Amélie; Deffaud, Julien; Wésolowski-Louvel, Micheline; Lemaire, Marc

    2014-01-01

    Sensing of extracellular glucose is necessary for cells to adapt to glucose variation in their environment. In the respiratory yeast Kluyveromyces lactis, extracellular glucose controls the expression of major glucose permease gene RAG1 through a cascade similar to the Saccharomyces cerevisiae Snf3/Rgt2/Rgt1 glucose signaling pathway. This regulation depends also on intracellular glucose metabolism since we previously showed that glucose induction of the RAG1 gene is abolished in glycolytic mutants. Here we show that glycolysis regulates RAG1 expression through the K. lactis Rgt1 (KlRgt1) glucose signaling pathway by targeting the localization and probably the stability of Rag4, the single Snf3/Rgt2-type glucose sensor of K. lactis. Additionally, the control exerted by glycolysis on glucose signaling seems to be conserved in S. cerevisiae. This retrocontrol might prevent yeasts from unnecessary glucose transport and intracellular glucose accumulation. PMID:25512610

  13. Glucagon-like peptide-1 (GLP-1) raises blood-brain glucose transfer capacity and hexokinase activity in human brain

    DEFF Research Database (Denmark)

    Gejl, Michael; Lerche, Susanne; Egefjord, Lærke

    2013-01-01

    In hyperglycemia, glucagon-like peptide-1 (GLP-1) lowers brain glucose concentration together with increased net blood-brain clearance and brain metabolism, but it is not known whether this effect depends on the prevailing plasma glucose (PG) concentration. In hypoglycemia, glucose depletion...... potentially impairs brain function. Here, we test the hypothesis that GLP-1 exacerbates the effect of hypoglycemia. To test the hypothesis, we determined glucose transport and consumption rates in seven healthy men in a randomized, double-blinded placebo-controlled cross-over experimental design. The acute...... effect of GLP-1 on glucose transfer in the brain was measured by positron emission tomography (PET) during a hypoglycemic clamp (3 mM plasma glucose) with (18)F-fluoro-2-deoxy-glucose (FDG) as tracer of glucose. In addition, we jointly analyzed cerebrometabolic effects of GLP-1 from the present...

  14. Blood glucose self-monitoring with a long-term subconjunctival glucose sensor.

    Science.gov (United States)

    Müller, Achim Josef; Knuth, Monika; Nikolaus, Katharina Sibylle; Krivánek, Roland; Küster, Frank; Hasslacher, Christoph; Auffarth, Gerd Uwe

    2013-01-01

    To evaluate the feasibility of an implantable subconjunctival glucose monitoring system (SGMS) for long-term glucose monitoring, we investigated the in vivo performance of the system. The SGMS consists of an implantable ocular mini implant (OMI) and a handheld fluorescence photometer. A clinical study was performed on 47 diabetes patients split into two cohorts. Two different types of OMI were used, with and without a biocompatible surface coating. Duration of the study was 1 year. Correlation between capillary blood glucose and SGMS-derived interstitial fluid glucose was investigated during the first 6 months of the study. Both OMI types were tolerated well in the eyes of the patients. At the beginning of the study, the SGMS of both cohorts revealed a high accuracy with mean absolute relative difference (MARD) values of 7-12%. The performance of the uncoated OMIs deteriorated within 3 months of wearing time, exhibiting a MARD value of 20%. The performance of the surface-coated OMIs was preserved longer. Glucose correlation measurement with reasonable results (MARD of 14%) could be performed for up to 6 months of wear. The biocompatible surface coating on the OMIs enabled a longer duration of action of up to 6 months compared with 3 months for uncoated implants in a clinical trial. © 2013 Diabetes Technology Society.

  15. Blood optical properties at various glucose level values in THz frequency range

    Science.gov (United States)

    Gusev, S. I.; Borovkova, M. A.; Strepitov, M. A.; Khodzitsky, M. K.

    2015-07-01

    The number of diabetics is rapidly growing every day in all parts of the world. By the year 2010, the number of patients suffering from diabetes had amounted to more than 230 million people, which is estimated as 3.5% of the whole world adult population [1]. According to expert forecasts, this number is projected to double by the year 2025, which is going to be 7% of whole Earth population. It was calculated that every 10 seconds someone in the world dies due to diabetes and its complications, which is 3 million people per year. The average life expectancy of children with diabetes is less than 28.3 years of onset. Diabetes is considered to be the fourth most common cause of death in industrialized countries. Vascular complications due to diabetes cause early disability and high mortality. Mortality from heart diseases and strokes is 2-3 times more likely for patients suffering from diabetes, whereas blindness, nephropathy and lower limbs gangrene happen respectively 10, 12-15 times, and almost 20 times more often for diabetics than general population. The number and strength of complications depend directly on the blood glucose level control quality. At the moment, the blood glucose level measurements are performed by glucometers [2,3]. This method requires that a patient makes a finger puncture for every measurement. About five punctures per day should be done for proper glucose monitoring, which is about 1,800 punctures per year. Besides, each measurement by glucometer requires a distinct test strip. Expenses for 1,800 test strips could be estimated as about 450 euros per year. It is also necessary to take into account that each puncture has a risk of blood poisoning. Using non-invasive techniques for glucose level control could reduce the amount of possible risky manipulations by 1800 per year. Moreover, it is worth mentioning that only eight of ten fingers are suitable for puncturing, and the constant skin damage which cannot be avoided is quite annoying for

  16. Flattening postprandial blood glucose responses with guar gum: acute effects.

    Science.gov (United States)

    McIvor, M E; Cummings, C C; Leo, T A; Mendeloff, A I

    1985-01-01

    It has been proposed that high-carbohydrate, high-fiber (HCF) diets might serve as useful therapeutic modality in non-insulin-dependent diabetes mellitus (NIDDM). One problem in evaluating clinical trials of this therapy is that, by their very nature, the trials cannot be double blinded. We have developed HCF and placebo granola-type bars using complex absorbable carbohydrate and guar gum fiber to circumvent this methodologic problem. The HCF bars, when consumed with an ad lib. diet, assure an HCF intake without imposing other dietary restrictions. To test the short-term efficacy of the bars, 9 normal adult volunteers, 2 women with impaired glucose tolerance, and 20 patients with NIDDM consumed the bars alone or with meals. Blood glucose responses when HCF bars were consumed alone were blunted when compared with the placebo response (P less than 0.0005 to P less than 0.002), with the most marked suppression occurring in the early postprandial period. In contrast, when the bars were consumed along with breakfast, HCF and placebo responses were virtually identical in the early postprandial period, but showed a progressively greater difference from 90 to 240 min (P less than 0.02 to P less than 0.0005). When consumed with lunch as well as breakfast, the HCF bars caused flattening of blood glucose responses during the late postprandial period after breakfast and maintained flattened responses during the early and late postprandial periods after lunch (P less than 0.05 to P less than 0.005). It is concluded that these HCF bars can be used to blunt postprandial blood glucose responses, in subjects with either normal or abnormal carbohydrate metabolism.

  17. Blood flow in skin, subcutaneous adipose tissue and skeletal muscle in the forearm of normal man during an oral glucose load

    DEFF Research Database (Denmark)

    Bülow, J; Astrup, A; Christensen, N J

    1987-01-01

    Blood flow to the forearm, and the subcutaneous tissue and skin in the forearm were measured by strain gauge plethysmography, 133Xe-elimination and Laser Doppler flowmetry during an oral glucose load (I g glucose kg-1 lean body mass) and during control conditions. The forearm blood flow remained......, muscle blood flow decreased about 20-30% during both experiments. Proximal nervous blockade did not abolish the glucose-induced vasodilatation in subcutaneous tissue. In the glucose experiment, arterial glucose concentration increased to 7.8 +/- 1.17 mmol l-1 30 min after the load was given...... constant during both experiments. Glucose induced a two-fold vasodilatation in subcutaneous tissue. In skin, glucose induced a relative vasodilatation and later a relative vasoconstriction compared with control experiments. When estimated from forearm blood flow and subcutaneous and skin blood flows...

  18. New innovative glucose-controlled pump enabling glucose control in a pregnant patitient with diabetes

    DEFF Research Database (Denmark)

    Pilemann-Lyberg, Sascha; Solis, Anette Bratt; Mathiesen, Elisabeth R

    2014-01-01

    Abstract Continuous glucose monitoring enables innovative insulin pumps to stop infusion of insulin at selected blood glucose thresholds. We present the first and successful Danish clinical case using this device, a Medtronics Veo insulin pump, in a patient with numerous cases of severe...... hypoglycaemia during earlier pregnancies. During this treatment insulin infusion was frequently stopped and severe hypoglycaemia prevented in the remaining part of pregnancy...

  19. Lived experience of blood glucose self-monitoring among pregnant women with gestational diabetes mellitus: a phenomenological research.

    Science.gov (United States)

    Youngwanichsetha, Sununta; Phumdoung, Sasitorn

    2017-10-01

    To explore and describe lived experience of blood glucose self-monitoring among pregnant Thai women with gestational diabetes mellitus. Self-monitoring of blood glucose is an essential practice among pregnant women with diabetes to prevent complications in pregnancy and the newborn infant. Phenomenological research was employed to understand lived experiences in glycemic control. Thirty participants were approached and interviewed using a semistructured interview guides. Qualitative data were analysed following Colaizzi's method. The findings revealed three themes: being worried about diabetes and blood testing, trying to control it and being patient for the child. Their worry comprised three dimensions: (1) wondering about the impacts of diabetes on the child, (2) concern about maternal health and (3) being worried about doing blood test. Trying to control diabetes was composed of three dimensions: (1) learning to test blood glucose, (2) being afraid of elevated blood sugar and (3) being aware of what to eat. Being patient for the child was composed of three dimensions: (1) overcoming food desires, (2) tolerating the fingerprick pain and (3) satisfaction with the outcomes. Women with gestational diabetes experienced being worried and afraid regarding blood glucose self-monitoring; however, they could overcome and tolerate this with some difficulties. These findings can be used to guide nursing practice in assessment of perception and response towards blood glucose self-monitoring in order to improve achievement of a good glycaemic control among pregnant women with gestational diabetes mellitus. © 2016 John Wiley & Sons Ltd.

  20. Radially oriented nanostrand electrodes to boost glucose sensing in mammalian blood.

    Science.gov (United States)

    Akhtar, Naeem; El-Safty, Sherif A; Abdelsalam, Mamdouh E; Shenashen, Mohamed A; Kawarada, Hiroshi

    2016-03-15

    Architecture of nanoscale electrochemical sensors for ultra-trace detection of glucose in blood is important in real-life sampling and analysis. To broaden the application of electrochemical sensing of glucose, we fabricated, for the first time, a glucose sensor electrode based on radially oriented NiO nanostrands (NSTs) onto 3D porous Ni foam substrate for monitoring, as well as selective and sensitive sensing of glucose in mammalian blood. The simple, scalable one-pot fabrication of this NST-Ni sensor design enabled control of the pattern of radially oriented NSTs onto 3D porous Ni foam substrate. The radial orientation of NST-Ni electrode onto the interior of the 3D porous substrate with controlled crystal structure size and atomic arrangement along the axis of the strands, intrinsic surface defects, and superior surface properties, such as hydrophilicity, high surface energy, and high density led to highly exposed catalytic active sites. The hierarchical NST-Ni electrode was used to develop a sensitive and selective sensor over a wide range of glucose concentrations among actively competitive ions, chemical species and molecular agents, and multi-cyclic sensing assays. The NST-Ni electrode shows significant glucose sensing performance in terms of unimpeded diffusion pathways, a wide range of concentration detection, and lower limit of detection (0.186 µM) than NiO nanosheet (NS)-Ni foam electrode pattern, indicating the effectiveness of the shape-dependent structural architecture of NST-Ni electrode. In this study, the NST-Ni electrode is fabricated to develop a simple, selective method for detecting glucose in physiological fluids (e.g., mammalian blood). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. The influence of blood glucose level on distribution of 18F-FDG in mice with tumor

    International Nuclear Information System (INIS)

    Fu Zhanli; Lin Jinghui; Wang Rongfu; Zhu Shaoli; Zhang Chunli; Pan Zhongyun

    2003-01-01

    To explore the influence of blood glucose level on 18 F-FDG uptake in tumor and normal tissues of mice, thirty five mice carrying Ehrlich ascitic cancer (EAC) are fasted 20 h and divided into four groups. The glucose loading group (n=12) and the control group (n=11) is given a solution of 50% glucose and distilled water orally just one hour before the 18 F FDG injection. Another two groups (n=5, n=7) is given a solution of 10%, 30% glucose respectively. Before 18 F-FDG intravenous injection, blood glucose levels are measured. The mice are killed one hour after the 18 F FDG injection. The tumor and normal tissues are excised, weighed, and counted by a γ well counter. The quantity of 18 F-FDG uptake is expressed as standardized uptake value (SUV). Blood glucose levels of the mice with EAC in the glucose loading group are significantly elevated than the control group (11.98 ± 3.01 mmol/L vs. 3.95 ± 1. 11 mmol/L, P 18 F-FDG uptake ratios of tumor and muscle in the glucose-loading group (1.34, 0.86, 0.48, 0.09, 1.38 respectively) are significantly lower than those in the control group (3.02, 2.62, 0.80, 0.16, 5.38 respectively) (P 18 F-FDG uptake ratios of tumor and brain, heart and blood in the glucose loading group (8.31. 1.05, 1.58, 103.00 respectively) are significantly higher than those in the control group (1.57, 0.64, 1.20, 9.73 respectively) (P 18 F-FDG distribution in mice. suggesting the blood glucose level should be controlled during clinically 18 F-FDG imaging

  2. Different training status may alter the continuous blood glucose kinetics in self-paced endurance running

    OpenAIRE

    SUZUKI, YOSHIO; SHIMIZU, TOMOMI; OTA, MAKOTO; HIRATA, RYUZO; SATO, KENJI; TAMURA, YOSHIFUMI; IMANISHI, AKIO; WATANABE, MASAYUKI; SAKURABA, KEISHOKU

    2015-01-01

    The main purpose of the systemic energy metabolism is to provide a source of energy, mainly glucose, for the brain; therefore, blood glucose levels would be expected to correlate with exercise performance. The individual training status may also affect the blood glucose levels. The aim of the present study was to assess the association between blood glucose levels and running velocity during prolonged running in athletes with different training statuses. Two female college athletes, a triathl...

  3. Development of a fluorescent method for simultaneous measurement of glucose concentrations in interstitial fluid and blood

    International Nuclear Information System (INIS)

    Shi, Ting; Li, Dachao; Li, Guoqing; Xu, Kexin; Chen, Limin; Lin, Yuan; Lu, Luo

    2013-01-01

    Continuous blood glucose monitoring is of great clinical significance to patients with diabetes. One of the effective methods to monitor blood glucose is to measure glucose concentrations of interstitial fluid (ISF). However, a time-delay problem exists between ISF and blood glucose concentrations, which results in difficulty in indicating real-time blood glucose concentrations. Therefore, we developed a fluorescent method to verify the accuracy and reliability of simultaneous ISF and blood glucose measurement, especially incorporating it into research on the delay relationship between blood and ISF glucose changes. This method is based on a competitive reaction among borate polymer, alizarin and glucose. When glucose molecules combine with borate polymers in alizarin–borate polymer competitively, changes in fluorescence intensity demonstrate changes in glucose concentrations. By applying the measured results to the blood and ISF glucose delay relationship, we were able to calculate the time delay as an average of 2.16 ± 2.05 min for ISF glucose changes with reference to blood glucose concentrations. (paper)

  4. Glucose control in pregnant women with type 1 diabetes mellitus: Studies using a continuous glucose monitoring system

    NARCIS (Netherlands)

    Kerssen, Anneloes

    2005-01-01

    Pregnancy in women with type 1 diabetes mellitus is associated with neonatal morbidity. It is commonly agreed that the morbidity decreases when diabetic control is tightened. The most common methods for the determination of diabetic control are the self-monitoring of blood glucose levels (SMBG) and

  5. Closed-loop controlled noninvasive ultrasonic glucose sensing and insulin delivery

    Science.gov (United States)

    Park, Eun-Joo; Werner, Jacob; Jaiswal, Devina; Smith, Nadine Barrie

    2010-03-01

    To prevent complications in diabetes, the proper management of blood glucose levels is essential. Previously, ultrasonic transdermal methods using a light-weight cymbal transducer array has been studied for noninvasive methods of insulin delivery for Type-1 diabetes and glucose level monitoring. In this study, the ultrasound systems of insulin delivery and glucose sensing have been combined by a feedback controller. This study was designed to show the feasibility of the feedback controlled ultrasound system for the noninvasive glucose control. For perspective human application, in vivo experiments were performed on large animals that have a similar size to humans. Four in vivo experiments were performed using about 200 lbs pigs. The cymbal array of 3×3 pattern has been used for insulin delivery at 30 kHz with the spatial-peak temporal-peak intensity (Isptp) of 100 mW/cm2. For glucose sensing, a 2×2 array was operated at 20 kHz with Isptp = 100 mW/cm2. Based on the glucose level determined by biosensors after the ultrasound exposure, the ultrasound system for the insulin delivery was automatically operated. The glucose level of 115 mg/dl was set as a reference value for operating the insulin delivery system. For comparison, the glucose levels of blood samples collected from the ear vein were measured by a commercial glucose meter. Using the ultrasound system operated by the close-loop, feed-back controller, the glucose levels of four pigs were determined every 20 minutes and continuously controlled for 120 minutes. In comparison to the commercial glucose meter, the glucose levels determined by the biosensor were slightly higher. The results of in vivo experiments indicate the feasibility of the feedback controlled ultrasound system using the cymbal array for noninvasive glucose sensing and insulin delivery. Further studies on the extension of the glucose control will be continued for the effective method of glucose control.

  6. Intensive glucose control versus conventional glucose control for type 1 diabetes mellitus.

    Science.gov (United States)

    Fullerton, Birgit; Jeitler, Klaus; Seitz, Mirjam; Horvath, Karl; Berghold, Andrea; Siebenhofer, Andrea

    2014-02-14

    Clinical guidelines differ regarding their recommended blood glucose targets for patients with type 1 diabetes and recent studies on patients with type 2 diabetes suggest that aiming at very low targets can increase the risk of mortality. To assess the effects of intensive versus conventional glycaemic targets in patients with type 1 diabetes in terms of long-term complications and determine whether very low, near normoglycaemic values are of additional benefit. A systematic literature search was performed in the databases The Cochrane Library, MEDLINE and EMBASE. The date of the last search was December 2012 for all databases. We included all randomised controlled trials (RCTs) that had defined different glycaemic targets in the treatment arms, studied patients with type 1 diabetes, and had a follow-up duration of at least one year. Two review authors independently extracted data, assessed studies for risk of bias, with differences resolved by consensus. Overall study quality was evaluated by the 'Grading of Recommendations Assessment, Development, and Evaluation' (GRADE) system. Random-effects models were used for the main analyses and the results are presented as risk ratios (RR) with 95% confidence intervals (CI) for dichotomous outcomes. We identified 12 trials that fulfilled the inclusion criteria, including a total of 2230 patients. The patient populations varied widely across studies with one study only including children, one study only including patients after a kidney transplant, one study with newly diagnosed adult patients, and several studies where patients had retinopathy or microalbuminuria at baseline. The mean follow-up duration across studies varied between one and 6.5 years. The majority of the studies were carried out in the 1980s and all trials took place in Europe or North America. Due to the nature of the intervention, none of the studies could be carried out in a blinded fashion so that the risk of performance bias, especially for

  7. Effects of Yogic Exercises on Life Stress and Blood Glucose Levels in Nursing Students

    OpenAIRE

    Kim, Sang Dol

    2014-01-01

    [Purpose] This study was performed to investigate the effects of yogic exercises on life stress and blood glucose levels in nursing students. [Subjects and Methods] The study was a randomized controlled trial. Twenty-seven undergraduate nursing students were randomly selected, with 12 assigned to an exercise group and 15 assigned to a control group. The yogic exercises intervention was undertaken for 60 minutes one day a week for 12 weeks. It consisted of physical exercise (surya namaskara) c...

  8. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Blood flow rates of AV fistula can be affected by osmotic and oncotic pressures of blood and arterial blood pressures. Sodium, glucose, hemoglobin, and albumin are significant effectors, created osmotic and oncotic pressures [Table 3]. Blood levels of hemoglobin. (Hb), albumin, sodium (Na), and glucose ...

  9. Cerebral blood flow and glucose metabolism in appetite-related brain regions in type 1 diabetic patients after treatment with insulin detemir and NPH insulin: a randomized controlled crossover trial.

    Science.gov (United States)

    van Golen, Larissa W; IJzerman, Richard G; Huisman, Marc C; Hensbergen, Jolanda F; Hoogma, Roel P; Drent, Madeleine L; Lammertsma, Adriaan A; Diamant, Michaela

    2013-12-01

    To test the hypothesis that insulin detemir, which is associated with less weight gain than other basal insulin formulations, exerts its weight-modulating effects by acting on brain regions involved in appetite regulation, as represented by altered cerebral blood flow (CBF) or cerebral glucose metabolism (CMRglu). Twenty-eight male type 1 diabetic patients (age 36.9 ± 9.7 years, BMI 24.9 ± 2.7 kg/m(2), A1C 7.5 ± 0.6%) successfully completed a randomized crossover study, consisting of two periods of 12-week treatment with either insulin detemir or NPH insulin, both in combination with prandial insulin aspart. After each treatment period, patients underwent positron emission tomography scans to measure regional CBF and CMRglu. After 12 weeks, A1C, daily insulin doses, fasting insulin, and blood glucose levels were similar between treatments. Insulin detemir resulted in body weight loss, whereas NPH insulin induced weight gain (between-treatment difference 1.3 kg; P = 0.02). After treatment with insulin detemir relative to NPH insulin, CBF was higher in brain regions involved in appetite regulation, whereas no significant difference in CMRglu was observed. Treatment with insulin detemir versus NPH insulin resulted in weight loss, paralleled by increased CBF in appetite-related brain regions in the resting state, in men with well-controlled type 1 diabetes. These findings lend support to the hypothesis that a differential effect on the brain may contribute to the consistently observed weight-sparing effect of insulin detemir.

  10. Change of blood glucose level and its possible mechanism in patients with cerebral stroke

    International Nuclear Information System (INIS)

    Chen Weizhen; Zhang Yong; Zhang Zikang; Mo Congjian

    2003-01-01

    To study the mechanism of the change of blood glucose levels in patients with cerebral stroke, the levels of blood glucose, cortisol, glucogen, insulin, growth hormone, triiodothyronine (T 3 ), thyroxine (T 4 ) and adrenocorticotropic hormone (ACTH) were dynamically measured in 90 patients with cerebral stroke. The circumstances of brain middle line movement, lateral ventricle oppression and entrance brain ventricle of burst hematoma of the patients were examines by CT scan. The total incidence of hyperglycemia in the patients was 42.22%. The blood glucose level was positively related to the cortisol and glucogen levels, and negatively related to the T 3 level. The changed level of blood glucose and its related hormones both returned to normal range in 10 days. Both the ACTH level and the rate of cerebral pathological change in hyperglycemia group were significantly higher than that in normoglycemia and control groups. The rate of cerebral pathological change in elevated ACTH level group was higher than that in normal ACTH level group. The mechanism of hyperglycemia in the patients with cerebral stroke might be related to the stimulation of the hypothalamus, which may induce the discharge of ACTH and glucagon releasing factor, and to that the level of cortisol and glucagon increased, the level of T 3 decreased

  11. Glucose control: Non-insulin therapies

    African Journals Online (AJOL)

    Volume 56 No 1. S Afr Fam Pract 2014. Glucose control: Non-insulin therapies. This article is a direct extraction from Chapter 9 of The 2012 SEMDSA Guidelines for the Management of Type 2 Diabetes and should be read in conjunction with the SEMDSA 2012 Treatment Algorithm. The full guideline and poster summary is ...

  12. Effect of Andrographolide‭ Extract on Blood Glucose and Lipid Profile in Rats with Secondary Iron Overload

    Directory of Open Access Journals (Sweden)

    َArash Mehri Pirayvatlo

    2017-01-01

    Full Text Available Background & objectives: Iron overload is involved in the pathophysiology of many diseases including diabetes. In fact, the excess iron by creating free radicals makes damage to pancreas and leads to insulin resistance and diabetes. Andrographolide extract has hypoglycemic and antioxidant properties. This study has surveyed the effects of andrographolide on blood glucose and lipid profile in rats with secondary iron overload. Methods: In this experimental study, 36 male Wistar rats were randomly divided into 6 groups: the healthy control group, secondary iron overload group, secondary iron overload groups treated with a dose of 3.5 and 7 mg/kg of andrographolide extract, and andrographolide groups treated with a dose of 3.5 and 7 mg/kg of extract. Iron and extract were injected for 6 and 12 days, respectively. Blood samples were taken for measurement of blood glucose and lipid profiles. Data were analyzed using ANOVA test. Results: The pathological results of samples from liver of animals receiving iron showed that the iron was deposited in the liver tissues. Iron injection significantly increased blood glucose levels compared to healthy control group (p<0.05. In the iron overload group, andrographolide extract with a dose of 3.5 mg/kg or 7 mg/kg significantly decreased blood glucose levels (p<0.05. Iron injections did not increase the serum triglyceride and cholesterollevels. Injections of andrographolide extract with a dose of 3.5 mg/kg and 7 mg/kg, significantly decreased the cholesterol levels compared to iron receiving group (p<0.05. Conclusion: Results of this study showed that the andrographolide with different doses may be effective in the treatment of diabetes by reducing serum glucose and cholesterol levels.

  13. A case of perioperative glucose control by using an artificial pancreas in a patient with glycogen storage disease.

    Science.gov (United States)

    Yatabe, Tomoaki; Nakamura, Ryu; Kitagawa, Hiroyuki; Munekage, Masaya; Hanazaki, Kazuhiro

    2016-03-01

    A 57-year-old woman was diagnosed with type I glycogen storage disease in her twenties. She had undergone hepatectomy under general anesthesia with epidural anesthesia. Fifty minutes after the induction of anesthesia, a 20-gauge venous catheter was inserted in the patient's right hand, and an artificial pancreas (STG-55, Nikkiso Co., Tokyo, Japan) was connected for continuous glucose monitoring and automatic glucose control. Insulin was infused when the blood glucose level reached 120 mg/dL or higher, and glucose was infused when the level fell to 100 mg/dL or lower. After the Pringle maneuver, the blood glucose level increased, and insulin was administered automatically via an artificial pancreas. Hypoglycemia did not occur during the operation. After total parenteral nutrition was started in the intensive care unit (ICU), the blood glucose level increased, and the artificial pancreas controlled the blood glucose level through automatic insulin administration. Thirty-four hours after admission to the ICU, the artificial pancreas was removed because the blood sampling failed. After the removal of the artificial pancreas, blood glucose level was measured every 2 h until extubation. During the ICU stay, hypoglycemia never occurred, with the average blood glucose level being 144 mg/dL. In conclusion, the use of an artificial pancreas for perioperative blood glucose management in a patient with glycogen storage disease had the beneficial effect of enabling the management of blood glucose levels without hypoglycemia.

  14. The effect of aerobic exercise and barley β-glucan on blood glucose, body composition and blood pressure of diabetic women

    Directory of Open Access Journals (Sweden)

    Fatemeh Mokhtari

    2018-04-01

    Full Text Available Background: The incidence of type 2 diabetes increases with aging, unhealthy diets, obesity and sedentary lifestyles. The aim of this study was to investigate the combinational effect of a 12-week aerobic exercise and barley β-glucan (BBG on blood glucose, body composition and blood pressure in women with type 2 diabetes. Materials and Methods: In this semi-experimental study, 24 women with the mean age of 49 years and a blood glucose level of 110-280 mg/dl were purposefully selected and randomly divided into three groups: a group of aerobic exercise with diet (n=8, b diet group (n=8 c control group (n=8. The diet group consumed one barley bread, containing 4 g of β glucan, each day for 12 weeks. The group of aerobic exercise, who was on diet, participated in a progressive walking program with the intensity of %60-70% of maximal heart rate in addition to diet program (barley bread. Blood glucose, weight, fat percentage, and systolic and diastolic blood pressure levels were measured in pre-and post-training. Results: Results showed a significant decrease in the blood glucose level in the experimental groups compared to the control group, while no major changes were observed in body composition and blood pressure. Conclusion: It seems that the combined program (aerobic training with diet or consumption of β-glucan alone can decrease blood glucose in patients with diabetes.

  15. Correlation between macrosomia body indices and maternal fasting blood glucose.

    Science.gov (United States)

    Song, Y; Zhang, S; Song, W

    2014-05-01

    To explore the significance of neonatal body indices in identifying pathological macrosomia, we implemented a retrospective study of 254 neonates, including: 100 macrosomia of diabetic pregnancies, 77 macrosomia of healthy pregnancies and 77 normal neonates of healthy pregnancies, using their birth weight, body length, head circumference and chest circumference, to calculate neonatal body indices, multiple regression analysis of the correlation between newborn body indices and maternal fasting blood glucose. The Quetelet Index and Kaup Index of diabetic macrosomia is higher than that of non-diabetic macrosomia; HC:CC (ratio between head circumference and chest circumference) is reversed (p macrosomia.

  16. Dietary thylakoids suppress blood glucose and modulate appetite-regulating hormones in pigs exposed to oral glucose tolerance test

    DEFF Research Database (Denmark)

    Montelius, Caroline; Szwiec, Katarzyna; Kardas, Marek

    2014-01-01

    , either with or without addition of 0.5 g/kg body weight of thylakoid powder. RESULTS: The supplementation of thylakoids to the oral glucose tolerance test resulted in decreased blood glucose concentrations during the first hour, increased plasma cholecystokinin concentrations during the first two hours...... metabolism and appetite-regulating hormones during an oral glucose tolerance test in pigs fed a high fat diet. METHODS: Six pigs were fed a high fat diet (36 energy% fat) for one month before oral glucose tolerance test (1 g/kg d-glucose) was performed. The experiment was designed as a cross-over study...

  17. Personalized blood glucose prediction: A hybrid approach using grammatical evolution and physiological models.

    Directory of Open Access Journals (Sweden)

    Iván Contreras

    Full Text Available The large patient variability in human physiology and the effects of variables such as exercise or meals challenge current prediction modeling techniques. Physiological models are very precise but they are typically complex and specific physiological knowledge is required. In contrast, data-based models allow the incorporation of additional inputs and accurately capture the relationship between these inputs and the outcome, but at the cost of losing the physiological meaning of the model. In this work, we designed a hybrid approach comprising physiological models for insulin and grammatical evolution, taking into account the clinical harm caused by deviations from the target blood glucose by using a penalizing fitness function based on the Clarke error grid. The prediction models were built using data obtained over 14 days for 100 virtual patients generated by the UVA/Padova T1D simulator. Midterm blood glucose was predicted for the 100 virtual patients using personalized models and different scenarios. The results obtained were promising; an average of 98.31% of the predictions fell in zones A and B of the Clarke error grid. Midterm predictions using personalized models are feasible when the configuration of grammatical evolution explored in this study is used. The study of new alternative models is important to move forward in the development of alarm-and-control applications for the management of type 1 diabetes and the customization of the patient's treatments. The hybrid approach can be adapted to predict short-term blood glucose values to detect continuous glucose-monitoring sensor errors and to estimate blood glucose values when the continuous glucose-monitoring system fails to provide them.

  18. Impact of sodium–glucose cotransporter 2 inhibitors on blood pressure

    Directory of Open Access Journals (Sweden)

    Reed JW

    2016-10-01

    Full Text Available James W Reed Morehouse School of Medicine, Atlanta, GA, USA Abstract: SGLT2 inhibitors are glucose-lowering agents used to treat type 2 diabetes mellitus (T2DM. These agents target the kidney to promote urinary glucose excretion, resulting in improved blood glucose control. SGLT2-inhibitor therapy is also associated with weight loss and blood pressure (BP lowering. Hypertension is a common comorbidity in patients with T2DM, and is associated with excess morbidity and mortality. This review summarizes data on the effect of SGLT2 inhibitors marketed in the US (namely canagliflozin, dapagliflozin, or empagliflozin on BP in patients with T2DM. Boolean searches were conducted that included terms related to BP or hypertension with terms for SGLT2 inhibitors, canagliflozin, dapagliflozin, or empagliflozin using PubMed, Google, and Google Scholar. Data from numerous randomized controlled trials of SGLT2 inhibitors in patients with T2DM demonstrated clinically relevant reductions in both systolic and diastolic BP, assessed via seated office measurements and 24-hour ambulatory BP monitoring. Observed BP lowering was not associated with compensatory increases in heart rate. Circadian BP rhythm was also maintained. The mechanism of SGLT2 inhibitor-associated BP reduction is not fully understood, but is assumed to be related to osmotic diuresis and natriuresis. Other factors that may also contribute to BP reduction include SGLT2 inhibitor-associated decreases in body weight and reduced arterial stiffness. Local inhibition of the renin–angiotensin–aldosterone system secondary to increased delivery of sodium to the juxtaglomerular apparatus during SGLT2 inhibition has also been postulated. Although SGLT2 inhibitors are not indicated as BP-lowering agents, the modest decreases in systolic and diastolic BP observed with SGLT2 inhibitors may provide an extra clinical advantage for the majority of patients with T2DM, in addition to improving blood glucose

  19. Blood glucose concentrations in prehospital trauma patients with traumatic shock : A retrospective analysis

    NARCIS (Netherlands)

    Kreutziger, Janett; Lederer, Wolfgang; Schmid, Stefan; Ulmer, Hanno; Wenzel, Volker; Nijsten, Maarten W.; Werner, Daniel; Schlechtriemen, Thomas

    BACKGROUND: Deranged glucose metabolism after moderate to severe trauma with either high or low concentrations of blood glucose is associated with poorer outcome. Data on prehospital blood glucose concentrations and trauma are scarce. OBJECTIVES: The primary aim was to describe the relationship

  20. Effect of whey on blood glucose and insulin responses to composite breakfast and lunch meals in type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Frid, Anders H; Nilsson, Mikael; Holst, Jens Juul

    2005-01-01

    glycemic index (GI) with whey proteins may increase insulin secretion and improve blood glucose control in type 2 diabetic subjects. DESIGN: Fourteen diet-treated subjects with type 2 diabetes were served a high-GI breakfast (white bread) and subsequent high-GI lunch (mashed potatoes with meatballs...... insulin release and reduces postprandial blood glucose excursion after a lunch meal consisting of mashed potatoes and meatballs in type 2 diabetic subjects.......). The breakfast and lunch meals were supplemented with whey on one day; whey was exchanged for lean ham and lactose on another day. Venous blood samples were drawn before and during 4 h after breakfast and 3 h after lunch for the measurement of blood glucose, serum insulin, glucose-dependent insulinotropic...

  1. Effect of whey on blood glucose and insulin responses to composite breakfast and lunch meals in type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Frid, Anders H; Nilsson, Mikael; Holst, Jens Juul

    2005-01-01

    glycemic index (GI) with whey proteins may increase insulin secretion and improve blood glucose control in type 2 diabetic subjects. DESIGN: Fourteen diet-treated subjects with type 2 diabetes were served a high-GI breakfast (white bread) and subsequent high-GI lunch (mashed potatoes with meatballs......). The breakfast and lunch meals were supplemented with whey on one day; whey was exchanged for lean ham and lactose on another day. Venous blood samples were drawn before and during 4 h after breakfast and 3 h after lunch for the measurement of blood glucose, serum insulin, glucose-dependent insulinotropic...... polypeptide (GIP), and glucagon-like peptide 1 (GLP-1). RESULTS: The insulin responses were higher after both breakfast (31%) and lunch (57%) when whey was included in the meal than when whey was not included. After lunch, the blood glucose response was significantly reduced [-21%; 120 min area under...

  2. Fat Intake, Blood Pressure and Randomed Blood Glucose Levels as Risk Factor of Metabolic Syndrome in Adolescent of Junior School in Denpasar City

    Directory of Open Access Journals (Sweden)

    I Putu Suiraoka

    2017-07-01

    Full Text Available The metabolic syndrome in children is defined when 3 of the 5 components are classified: hypertension, low HDL cholesterol, high serum triglyceride, high blood glucose levels, and central obesity. This study was a retrospective study with case-control design. Data collection was conducted from August to October 2014. The population of this study were all students in 8 selected junior high schools. Based on the calculation result, it was known that the sample size for case and control group are 128 people. Case and control determination began with screening of waist circumference using a tape measure, measured from the diameter between the lower ribs 10 with the iliac crest at the end of normal expiration. Systolic and diastolic blood pressure was measured using a digital blood pressure gauge under the Omron brand. Blood glucose levels were measured using a multicheck parameter tool under the Nesco brand. BMI based on weight and height were measured using body scales and Microtoise. Fat intake data were collected using semi-quantitative food frequency method. Data were analyzed descriptively in the range and mean for waist circumference variable, blood pressure, randomed blood glucose levels, and fat intake. Furthermore, the calculation of Odd Ratio. Based on the results be concluded that adolescents who consume fat above 25% risk 3.3 times greater to experience metabolic syndrome. Systolic and diastolic blood pressure, BMI and blood glucose levels as the case group was higher than the control group.

  3. Effects of pre-germinated brown rice on blood glucose and lipid levels in free-living patients with impaired fasting glucose or type 2 diabetes.

    Science.gov (United States)

    Hsu, Tzu-Fang; Kise, Mitsuo; Wang, Ming-Fu; Ito, Yukihiko; Yang, Mei-Due; Aoto, Hiromichi; Yoshihara, Rie; Yokoyama, Jyunichi; Kunii, Daisuke; Yamamoto, Shigeru

    2008-04-01

    White rice (WR) is made by polishing brown rice (BR) and has lost various nutrients; however, most people prefer it to BR, maybe because of the hardness of BR. Pre-germinated brown rice (PGBR) improves the problem of BR. It is made by soaking BR kernels in water to germinate and becomes softer than BR. In this study we compared the effects of WR and PGBR on blood glucose and lipid concentrations in the impaired fasting glucose (IFG) or type 2 diabetes patients. Six men and 5 women with impaired fasting glucose (IFG) or type 2 diabetes were randomly allocated to 6 wk on WR or PGBR diet separated by a 2 wk washout interval in a crossover design. Each subject was instructed to consume 3 packs of cooked WR or PGBR (180 g/pack) daily in each intervention phase. Blood samples were collected 4 times (in study weeks 0, 6, 8 and 14) for biochemical examination. Blood concentrations of fasting blood glucose, fructosamine, serum total cholesterol and triacylglycerol levels were favorably improved on the PGBR diet (p<0.01), but not on the WR diet. The present results suggest that diets including PGBR may be useful to control blood glucose level.

  4. Opium can differently alter blood glucose, sodium and potassium in male and female rats.

    Science.gov (United States)

    Karam, Gholamreza Asadi; Rashidinejad, Hamid Reza; Aghaee, Mohammad Mehdi; Ahmadi, Jafar; Rahmani, Mohammad Reza; Mahmoodi, Mehdi; Azin, Hosein; Mirzaee, Mohammad Reza; Khaksari, Mohammad

    2008-04-01

    To determine the effects of opium on serum glucose, potassium and sodium in male and female Wistar rat, opium solution (60 mg/kg) injected intraperitoneally and the same volume of distilled water was used as control (7 rats in each group). Blood samples were collected at 0, 30, 60, 120, 240 and 360 minutes after injection from orbit cavity and the values of serum glucose, sodium (Na(+)) and potassium (K(+)) were measured. The data were then analyzed by the repeated measure ANOVA based on sex and case-control group. P opium solution injection, in female rats compared to a control group. However, the male rats had this rise at 30, 60 and 120 minutes after opium solution injection compared to control group. While serum glucose in male rats was significantly higher than females at 30, 60 and 120 minutes, this value was higher in the female rats at 360 minutes. Therefore, serum glucose alterations following opium injection was significantly different in groups and in the sexes at different times. Sodium (Na(+)) rose at 60, 240 and 360 minutes significantly in all rats compared to control group. However, sodium alteration following opium injection was significantly different only between treated and control groups but sex-independent at all times. Potassium (K(+)) increased significantly at 60, 120, 240 and 360 minutes in male rats, compared to a control group. In female rats K(+) significantly raised at 30, 120, 240 and 360 minutes. Therefore, the alteration of K(+) in male and female rats was found time dependent and sex independent. According to our results, opium increased serum glucose in male and female rats differently, and it interferes with metabolic pathways differently on a gender dependent basis. Opium raised serum Na(+) and K(+), thus it interfere with water regulation and blood pressure via different mechanism.

  5. Does high blood glucose mean more insulin? Type 1 diabetes management in children and adolescents.

    Science.gov (United States)

    Yee, Kwang C; Edwards, Keith N

    2003-09-01

    The growth and development occurring in children and adolescents with type 1 diabetes contributes to many medical and nonmedical factors that may affect diabetic control. This article discusses the assessment of high blood sugar levels in children and adolescents with type 1 diabetes. Traditionally, diet, exercise and insulin dose are seen as the determinants of blood glucose levels in type 1 diabetic patients. While these factors are important, other practical, medical and psychosocial factors need to be considered. Appropriate management requires more than just alteration of insulin dose. Insulin injection technique, adherence to insulin and management regimens in general, psychosocial issues, the role of intercurrent infections and the development of other medical problems need to be considered. Children and adolescents may only be seen by specialist physicians at three monthly intervals. Exploring these issues with patients during routine general practitioner consultations is likely to allow early identification of treatable problems and improve long term glucose control.

  6. Analysis of an Electrochemical Blood Glucose Monitoring System with Hematocrit Compensation: Improved Accuracy by Design

    OpenAIRE

    Lyon, Martha E; Lyon, Andrew W

    2012-01-01

    The article entitled “Hematocrit Compensation in Electrochemical Blood Glucose Monitoring Systems” by Teodorczyk and colleagues in this issue of Journal of Diabetes Science and Technology demonstrates that the OneTouch® Verio™ glucose meter meets current regulatory expectations for glucose meter performance and is relatively free from interference by hematocrit. The lack of influence of hematocrit on whole blood glucose results is a valuable attribute for hospital applications, where greater ...

  7. Different training status may alter the continuous blood glucose kinetics in self-paced endurance running.

    Science.gov (United States)

    Suzuki, Yoshio; Shimizu, Tomomi; Ota, Makoto; Hirata, Ryuzo; Sato, Kenji; Tamura, Yoshifumi; Imanishi, Akio; Watanabe, Masayuki; Sakuraba, Keishoku

    2015-09-01

    The main purpose of the systemic energy metabolism is to provide a source of energy, mainly glucose, for the brain; therefore, blood glucose levels would be expected to correlate with exercise performance. The individual training status may also affect the blood glucose levels. The aim of the present study was to assess the association between blood glucose levels and running velocity during prolonged running in athletes with different training statuses. Two female college athletes, a triathlete and a tennis player, ran a course that was 247.4 m in circumference for 5 h while wearing a continuous glucose monitoring system. Blood was obtained at time-points of -1, 1, 3 and 5 h. The athletes had free access to food and fluids throughout the run. The athletes ran at almost the same pace without a sudden decrease in pace. The blood glucose levels increased and remained high in the triathlete, whereas the tennis player remained hypoglycemic throughout the run. Carbohydrate ingestion did not affect the blood glucose levels. The magnitude of hormonal changes, e.g. insulin, adrenaline and cortisol, was greater in the tennis player. The blood glucose concentration did not correlate with the running velocity or the carbohydrate ingestion; however, a discrepancy in blood glucose transition was observed between the triathlete and the tennis player, indicating a possible association between the adaptation to endurance exercise and the blood glucose kinetics during prolonged running.

  8. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  9. Effect of Sodium-Glucose Cotransport-2 Inhibitors on Blood Pressure in People With Type 2 Diabetes Mellitus: A Systematic Review and Meta-Analysis of 43 Randomized Control Trials With 22 528 Patients.

    Science.gov (United States)

    Mazidi, Mohsen; Rezaie, Peyman; Gao, Hong-Kai; Kengne, Andre Pascal

    2017-05-25

    The sodium-glucose cotransporter 2 (SGLT2) inhibitors are a class of oral hypoglycemic agents. We undertake a systematic review and meta-analysis of prospective studies to determine the effect of SGLT2 on blood pressure (BP) among individuals with type 2 diabetes mellitus. PubMed-Medline, Web of Science, Cochrane Database, and Google Scholar databases were searched to identify trial registries evaluating the impact of SGLT2 on BP. Random-effects models meta-analysis was used for quantitative data synthesis. The meta-analysis indicated a significant reduction in systolic BP following treatment with SGLT2 (weighted mean difference -2.46 mm Hg [95% CI -2.86 to -2.06]). The weighted mean differences for the effect on diastolic BP was -1.46 mm Hg (95% CI -1.82 to -1.09). In these subjects the weighted mean difference effects on serum triglycerides and total cholesterol were -2.08 mg/dL (95% CI -2.51 to -1.64) and 0.77 mg/dL (95% CI 0.33-1.21), respectively. The weighted mean differences for the effect of SGLT2 on body weight was -1.88 kg (95% CI -2.11 to -1.66) across all studies. These findings were robust in sensitivity analyses. Treatment with SGLT2 glucose cotransporter inhibitors therefore has beneficial off-target effects on BP in patients with type 2 diabetes mellitus and may also be of value in improving other cardiometabolic parameters including lipid profile and body weight in addition to their expected effects on glycemic control. However, our findings should be interpreted with consideration for the moderate statistical heterogeneity across the included studies. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  10. Glucose monitoring technologies - complementary or competitive? Role of continuous glucose monitoring versus flash glucose monitoring versus self-monitoring of blood glucose

    Directory of Open Access Journals (Sweden)

    Jothydev Kesavadev

    2017-01-01

    Full Text Available We have numerous technologies that can help keep a close watch on an individual's glycaemic status and thereby assist in developing successful diabetes management strategies. For more than five decades, self-monitoring of blood glucose (SMBG has remained as the gold standard tool to manage glycaemic status and has gained huge acceptance. Rigorous research further led to the development of more and more advanced technologies such as continuous glucose monitoring and flash glucose monitoring. These novel technologies are more promising in terms of revealing the complete glycaemic picture and even more user-friendly than the already established blood glucosemetres. However, they are yet to achieve remarkable accuracy and performance. There will also be a subgroup of patients who will be using these technologies only occasionally and thus will definitely require SMBG at other times. Again, with regard to the retrospective ones, glucose data can be obtained only once they are downloaded to the system and hence, real-time values will still have to be procured with the help of an SMBG. In future when the accuracy and performance of these newer technologies become equal to that of glucometres, the glucometres might vanish. Until then, all these technologies will definitely go hand-in-hand and supplement each other than competing each other. All the related literature were retrieved from various databases including 'PubMed' and 'Cochrane Database of Systematic Reviews' using specific search terms that were relevant to the topics discussed this manuscript.

  11. Chronic fructose substitution for glucose or sucrose in food or beverages has little effect on fasting blood glucose, insulin, or triglycerides: a systematic review and meta-analysis.

    Science.gov (United States)

    Evans, Rebecca A; Frese, Michael; Romero, Julio; Cunningham, Judy H; Mills, Kerry E

    2017-08-01

    Background: Conflicting evidence exists on the role of long-term fructose consumption on health. No systematic review has addressed the effect of isoenergetic fructose replacement of other sugars and its effect on glycated hemoglobin (HbA1c), fasting blood glucose, insulin, and triglycerides. Objective: The objective of this study was to review the evidence for a reduction in fasting glycemic and insulinemic markers after chronic, isoenergetic replacement of glucose or sucrose in foods or beverages by fructose. The target populations were persons without diabetes, those with impaired glucose tolerance, and those with type 2 diabetes. Design: We searched the Cochrane Library, MEDLINE, EMBASE, the WHO International Clinical Trials Registry Platform Search Portal, and clinicaltrials.gov The date of the last search was 26 April 2016. We included randomized controlled trials of isoenergetic replacement of glucose, sucrose, or both by fructose in adults or children with or without diabetes of ≥2 wk duration that measured fasting blood glucose. The main outcomes analyzed were fasting blood glucose and insulin as well as fasting triglycerides, blood lipoproteins, HbA1c, and body weight. Results: We included 14 comparison arms from 11 trials, including 277 patients. The studies varied in length from 2 to 10 wk (mean: 28 d) and included doses of fructose between 40 and 150 g/d (mean: 68 g/d). Fructose substitution in some subgroups resulted in significantly but only slightly lowered fasting blood glucose (-0.14 mmol/L; 95% CI: -0.24, -0.036 mmol/L), HbA1c [-10 g/L (95% CI: -12.90, -7.10 g/L; impaired glucose tolerance) and -6 g/L (95% CI: -8.47, -3.53 g/L; normoglycemia)], triglycerides (-0.08 mmol/L; 95% CI: -0.14, -0.02 mmol/L), and body weight (-1.40 kg; 95% CI: -2.07, -0.74 kg). There was no effect on fasting blood insulin or blood lipids. Conclusions: The evidence suggests that the substitution of fructose for glucose or sucrose in food or beverages may be of benefit

  12. Elevated 1-h post-challenge plasma glucose levels in subjects with normal glucose tolerance or impaired glucose tolerance are associated with whole blood viscosity.

    Science.gov (United States)

    Marini, Maria Adelaide; Fiorentino, Teresa Vanessa; Andreozzi, Francesco; Mannino, Gaia Chiara; Perticone, Maria; Sciacqua, Angela; Perticone, Francesco; Sesti, Giorgio

    2017-08-01

    It has been suggested that glucose levels ≥155 mg/dl at 1-h during an oral glucose tolerance test (OGTT) may predict development of type 2 diabetes and cardiovascular events among adults with normal glucose tolerance (NGT 1 h-high). Studies showed a link between increased blood viscosity and type 2 diabetes. However, whether blood viscosity is associated with dysglycemic conditions such as NGT 1 h-high, impaired glucose tolerance (IGT) or impaired fasting glucose (IFG) is unsettled. 1723 non-diabetic adults underwent biochemical evaluation and OGTT. A validated formula based on hematocrit and total plasma proteins was employed to estimate whole blood viscosity. Subjects were categorized into NGT with 1 h glucose h-low), NGT-1 h-high, IFG and/or IGT. Hematocrit and blood viscosity values appeared significantly higher in individuals with NGT 1 h-high, IFG and/or IGT as compared to NGT 1 h-low subjects. Blood viscosity was significantly correlated with age, waist circumference, blood pressure, HbA1c, fasting, 1- and 2-h post-challenge insulin levels, total cholesterol and low-density lipoprotein, triglycerides, fibrinogen, white blood cell, and inversely correlated with high-density lipoprotein and insulin sensitivity. Of the four glycemic parameters, 1-h post-challenge glucose showed the strongest correlation with blood viscosity (β = 0.158, P h post-challenge plasma glucose. They also suggest that a subgroup of NGT individuals with 1-h post-challenge plasma >155 mg/dl have increased blood viscosity comparable to that observed in subjects with IFG and/or IGT.

  13. The Effects of Blood Glucose Levels on Cognitive Performance: A Review of the Literature

    Science.gov (United States)

    Feldman, Jolene; Barshi, Immanuel

    2007-01-01

    The purpose of this review paper is to discuss the research literature on the effects of blood glucose levels on executive and non-executive functions in humans. The review begins with a brief description of blood glucose, how it has been studied, previous syntheses of prior studies, and basic results regarding the role of blood glucose on cognitive functioning. The following sections describe work that investigated the effect of blood glucose on both non-executive and executive functions (e.g., sensory processing, psychomotor functioning, attention, vigilance, memory, language and communication, judgement and decision-making, and complex task performance). Within each section, summaries of the findings and challenges to the literature are included. Measurement conversions of blood glucose levels, blood glucose values, and associated symptoms are depicted. References to the types of tests used to investigate blood glucose and cognitive performance are provided. For more detailed descriptions of references within (and in addition to) this paper, an annotated bibliography is also provided. Several moderator variables including individual differences and contextual variables related to the effects of blood glucose levels on performance (e.g., age, gender, time of day, familiarity with the task and symptom awareness, expectancy effects, dose dependent effects, time dependent effects, task specific effects, rising and falling blood glucose levels, and speed and/or accuracy trade-offs) are addressed later in the paper. Some suggestions for future experimental methodologies are also made.

  14. Alterations in body weight and blood glucose level of female hamsters exposed to electromagnetic fields of cell phones

    Directory of Open Access Journals (Sweden)

    A.R Lotfi

    2010-02-01

    Group 2 was exposed to electromagnetic field emitted by cell phones for 10 days (short term and group 3 for 50 day (long term. In the latter groups, the exposure was 1 hour per day. At the end of the experimental period, the animals were weighed and blood glucose concentrations were determined by obtaining blood samples from 8 randomly selected hamsters in each group.  The blood glucose level was significantly higher in long-term exposed group in comparison with the control and short-term exposed groups (175, 11.6 and 107 mg/dl, respectively (p

  15. A Model of Self-Monitoring Blood Glucose Measurement Error.

    Science.gov (United States)

    Vettoretti, Martina; Facchinetti, Andrea; Sparacino, Giovanni; Cobelli, Claudio

    2017-07-01

    A reliable model of the probability density function (PDF) of self-monitoring of blood glucose (SMBG) measurement error would be important for several applications in diabetes, like testing in silico insulin therapies. In the literature, the PDF of SMBG error is usually described by a Gaussian function, whose symmetry and simplicity are unable to properly describe the variability of experimental data. Here, we propose a new methodology to derive more realistic models of SMBG error PDF. The blood glucose range is divided into zones where error (absolute or relative) presents a constant standard deviation (SD). In each zone, a suitable PDF model is fitted by maximum-likelihood to experimental data. Model validation is performed by goodness-of-fit tests. The method is tested on two databases collected by the One Touch Ultra 2 (OTU2; Lifescan Inc, Milpitas, CA) and the Bayer Contour Next USB (BCN; Bayer HealthCare LLC, Diabetes Care, Whippany, NJ). In both cases, skew-normal and exponential models are used to describe the distribution of errors and outliers, respectively. Two zones were identified: zone 1 with constant SD absolute error; zone 2 with constant SD relative error. Goodness-of-fit tests confirmed that identified PDF models are valid and superior to Gaussian models used so far in the literature. The proposed methodology allows to derive realistic models of SMBG error PDF. These models can be used in several investigations of present interest in the scientific community, for example, to perform in silico clinical trials to compare SMBG-based with nonadjunctive CGM-based insulin treatments.

  16. Effects of Chlorophyll in Papaya Leaves on Superoxide Dismutation and Blood Glucose Level of Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Choirun Nissa

    2015-08-01

    Full Text Available Hyperglycemia in diabetes mellitus results in oxidative stress and increases complication development. Experimental studies have shown that chlorophyll has antioxidant activity and papaya leaves contained chlorophyll more than the other green vegetables. This study aimed to evaluate the antioxidant and hypoglycemic role in chlorophyll rich in papaya leaves on diabetic rats. Thirty six rats were randomly divided into 4 groups: without treatment (technique control/TC, diabetic (negative control/NC, diabetic with treatment A (100.3 mg/200 g BW of extract and diabetic with treatment B (200.6 mg/200 g BW of extract. Diabetic induction was conducted by injecting streptozotocin 40 mg/kg BW intraperitoneally. Extract was given by nasogastric tube. Blood glucose level was measured using enzymatic colorimetric GOD-PAP test at before, after 20 and 40 days of treatment. Hepatic superoxide dismutation (SOD level was measured after 40 days of treatment. Blood glucose levels in 3 diabetic groups were significantly raised after seven days of induction. In Anova and post hoc LSD analysis, both treatments had lower hepatic SOD level than TC (p=0.0001, and blood glucose level also decreased after given the treatment (p=0.0001. Treatment B had a better antioxidant and hypoglycemic role than treatment A.

  17. Chickpeas suppress postprandial blood glucose concentration, and appetite and reduce energy intake at the next meal.

    Science.gov (United States)

    Zafar, Tasleem A; Kabir, Yearul

    2017-03-01

    The current study was designed to explore the beneficial properties of chickpeas consumption on suppressing appetite, excessive blood glucose excursions, and energy intake (EI) from a subsequent meal. Two caloric preloaded foods, chickpeas, and white bread were compared to water control, fed to healthy female subjects at equal energy density, volume, and available carbohydrate content in two experiments spanning over 60 and 120 min. Blood glucose was measured by a portable glucometer and satiety by using a visual analogue scale questionnaire at baseline and every 15 up to 60 min in both experiments and then every 30 until 120 min in Experiment 2 after the preloads ingestion. A test meal was served at the end of both experiments to calculate EI and percent energy compensation (%EC). The results suggest a reduction of 29-36% in blood glucose concentration, and 83-98% EC after the chickpeas in Experiments 1 and 2 respectively compared to white bread. The average appetite showed a positive association with EI. We conclude that the consumption of chickpeas is beneficial on glycemic control and may help in body weight management through suppressing appetite and energy intake.

  18. Effects of laser acupoint irradiation on blood glucose and glycosylated hemoglobin in type 2 diabetes mellitus

    Science.gov (United States)

    Hui-Hui, Liu; Guo-Xin, Xiong; Li-Ping, Zhang

    2016-06-01

    To investigate the effects of semiconductor laser acupoint irradiation on blood glucose, glycosylated hemoglobin and physical fitness in type 2 diabetes mellitus, 44 cases of type 2 diabetic patients were randomly divided into a control group and a treatment group. All patients in both groups were given a drug treatment. The Hegu, Quchi and Zusanli acupoints of patients in the treatment group were then irradiated daily for 15 d with a 10 MW semiconductor laser. Before and after treatment, patients in both groups underwent a variety of tests and measurements: a two-hour postprandial blood glucose test; a glycosylated hemoglobin test and body mass index (BMI), waist-to-hip ratio (WHR) and body fat percentage (BFP) measurements. The data detected after treatment greatly decreased in the treatment group and was significantly different from that in the control group. It is shown that the acupoint irradiation with a semiconductor laser can improve two-hour postprandial blood glucose, glycosylated hemoglobin and some physical fitness measurements in type 2 diabetes mellitus patients.

  19. Diminished insulin-mediated forearm blood flow and muscle glucose uptake in young men with low birth weight

    DEFF Research Database (Denmark)

    Sonne, M P; Højbjerre, L; Alibegovic, A C

    2009-01-01

    with venous occlusion plethysmography and intra-arterial infusions of adenosine and acetylcholine, before and during a hyperinsulinemic isoglycemic clamp. RESULTS: Forearm blood flow response to systemic hyperinsulinemia was diminished in LBW compared to controls (p Fractional arteriovenous glucose...... extraction was similar, and consequently insulin-stimulated forearm glucose clearance was diminished in LBW compared with controls (0.8 +/- 0.09 vs. 1.4 +/- 0.36 ml x 100 ml(-1) x min(-1), respectively, p blood flow response to adenosine and acetylcholine with or without insulin stimulation...... did not differ between groups. Whole-body glucose uptake was lower in LBW than controls (8.7 +/- 0.5 and 9.1 +/- 0.6 mg x min(-1) x kg(-1) lean body mass); however, this was not significant. CONCLUSIONS: Forearm blood flow response to insulin is impaired in LBW, whereas the response to adenosine...

  20. Regional cerebral effects of ketone body infusion with 3-hydroxybutyrate in humans: Reduced glucose uptake, unchanged oxygen consumption and increased blood flow by positron emission tomography. A randomized, controlled trial.

    Science.gov (United States)

    Svart, Mads; Gormsen, Lars C; Hansen, Jakob; Zeidler, Dora; Gejl, Michael; Vang, Kim; Aanerud, Joel; Moeller, Niels

    2018-01-01

    Ketone bodies are neuroprotective in neurological disorders such as epilepsy. We randomly studied nine healthy human subjects twice-with and without continuous infusion of 3-hydroxybutyrate-to define potential underlying mechanisms, assessed regionally (parietal, occipital, temporal, cortical grey, and frontal) by PET scan. During 3-hydroxybutyrate infusions concentrations increased to 5.5±0.4 mmol/l and cerebral glucose utilisation decreased 14%, oxygen consumption remained unchanged, and cerebral blood flow increased 30%. We conclude that acute 3-hydroxybutyrate infusion reduces cerebral glucose uptake and increases cerebral blood flow in all measured brain regions, without detectable effects on cerebral oxygen uptake though oxygen extraction decreased. Increased oxygen supply concomitant with unchanged oxygen utilisation may contribute to the neuroprotective effects of ketone bodies.

  1. The Great Recession worsened blood pressure and blood glucose levels in American adults.

    Science.gov (United States)

    Seeman, Teresa; Thomas, Duncan; Merkin, Sharon Stein; Moore, Kari; Watson, Karol; Karlamangla, Arun

    2018-03-27

    Longitudinal, individual-specific data from the Multi-Ethnic Study of Atherosclerosis (MESA) provide support for the hypothesis that the 2008 to 2010 Great Recession (GR) negatively impacted the health of US adults. Results further advance understanding of the relationship by ( i ) illuminating hypothesized greater negative impacts in population subgroups exposed to more severe impacts of the GR and ( ii ) explicitly controlling for confounding by individual differences in age-related changes in health over time. Analyses overcome limitations of prior work by ( i ) employing individual-level data that avoid concerns about ecological fallacy associated with prior reliance on group-level data, ( ii ) using four waves of data before the GR to estimate and control for underlying individual-level age-related trends, ( iii ) focusing on objective, temporally appropriate health outcomes rather than mortality, and ( iv ) leveraging a diverse cohort to investigate subgroup differences in the GR's impact. Innovative individual fixed-effects modeling controlling for individual-level age-related trajectories yielded substantively important insights: ( i ) significant elevations post-GR for blood pressure and fasting glucose, especially among those on medication pre-GR, and ( ii ) reductions in prevalence and intensity of medication use post-GR. Important differences in the effects of the GR are seen across subgroups, with larger effects among younger adults (who are likely still in the labor force) and older homeowners (whose declining home wealth likely reduced financial security, with less scope for recouping losses during their lifetime); least affected were older adults without a college degree (whose greater reliance on Medicare and Social Security likely provided more protection from the recession).

  2. [Interference of the blood glucose control in the transition between phases I and II of lactogenesis in patients with type 1 diabetes mellitus].

    Science.gov (United States)

    Oliveira, Angela M de Morais; Cunha, Cleine Chagas da; Penha-Silva, Nilson; Abdallah, Vânia Olivetti Steffen; Jorge, Paulo Tannus

    2008-04-01

    Lactogenesis is constituted by phases I and II. The transition between those phases is characterized by an increase of the lactose concentration in the colostrum. This study aimed to evaluate the interference of type 1 Diabetes mellitus in the transition between phases I and II of the lactogenesis. The lactose concentration was determined in colostrum samples of 11 puerperal women with pre-gestational Diabetes mellitus and 19 without the disease, during the five first days of the puerperium. The lactose concentration was determined by reaction with picric acid. In both groups there were progressive increases in the lactose levels along the time; however, the increase was significantly lower in the 3rd and 5th days for the group of the women with diabetes. The analysis of the transition between the lactogenesis phases revealed that the puerperal diabetic women with inadequate glycemic control presented a time delay of 18 hours to reach phase II, making difficult the establishment of breastfeeding.

  3. Once Daily Self-Monitoring of Blood Glucose (SMBG) Improves Glycemic Control in Oral Hypoglycemic Agents (OHA)-Treated Diabetes: SMBG-OHA Follow-Up Study.

    Science.gov (United States)

    Harashima, Shin-Ichi; Nishimura, Akiko; Ikeda, Kaori; Wang, Yu; Liu, Yanyan; Inagaki, Nobuya

    2015-10-01

    The aim of this study was to compare glycemic control between SMBG-continued and -discontinued subjects with type 2 diabetes in the SMBG-OHA study. Of the 96 subjects from the SMBG-OHA study, 59 were recruited for the 24-week, comparison follow-up study. The study outcomes were the differences in change in HbA1c levels at 24 weeks between the 2 groups, and change in SMBG frequency in SMBG-continued subjects. Although health insurance does not cover the cost of SMBG, 22.0% of subjects continued SMBG of their own will after the SMBG-OHA study was completed. HbA1c levels were maintained from 6.81 ± 0.55% to 6.64 ± 0.53% in SMBG-continued subjects. Conversely, HbA1c levels were increased from 7.18 ± 0.63% to 7.48 ± 0.84% in SMBG-discontinued subjects. HbA1c levels were significantly different by 0.83 ± 0.25% (95% CI: -1.33 to -0.36). The difference in change in HbA1c between the groups was -0.46% (95% CI: -0.78 to -0.15). SMBG frequency was decreased from 2.02 ± 1.06 to 1.53 ± 0.86 times a day. HbA1c levels were maintained in SMBG-continued subjects but increased in SMBG-discontinued subjects. The study implied that almost once daily SMBG is helpful to maintain glycemic control in non-insulin-treated type 2 diabetes. © 2015 Diabetes Technology Society.

  4. Comparison of glucose concentration and glucose absorption from the GI-tract in pigs in whole blood and in plasma

    DEFF Research Database (Denmark)

    Theil, Peter Kappel; Jørgensen, Henry; Larsen, Torben

    2010-01-01

    glucose measured in whole blood (x-variable) and in plasma (y-variable) gave the following equations: Y = 0.974 X + 0.55, n = 583 (Exp. 1) and Y = 0.949 X + 0.65, n = 655 (Exp. 2). The net absorption of glucose found in blood was in accordance with that found in plasma: Y = 1.012 X , n = 281 (no intercept......, P = 0.79; Exp. 1) and Y = 0.954 X, n = 316 (no intercept, P = 0.97; Exp. 2). It was concluded that glucose measured in blood and plasma were slightly biased whereas net glucose absorption in blood and in plasma were unbiased......The present investigation was undertaken to compare glucose absorption from the gastro-intestinal tract quantified in either whole blood or plasma using the arterio-venous differences and portal blood flow measurements. Pigs were surgically modified with catheters in the portal vein...

  5. High incidence of hypoglycemia in stable insulin-treated type 2 diabetes mellitus: continuous glucose monitoring vs. self-monitored blood glucose. Observational prospective study.

    Science.gov (United States)

    Pazos-Couselo, Marcos; García-López, Jose Manuel; González-Rodríguez, Maria; Gude, Francisco; Mayán-Santos, Jose Manuel; Rodríguez-Segade, Santiago; Rodríguez-García, Javier; Casanueva, Felipe

    2015-10-01

    Hypoglycemia is a limiting factor in the achievement of strict glycemic control. The primary objective of this 9-week study was to determine the frequency of hypoglycemia in patients with stable insulin-treated type 2 diabetes mellitus by comparing self-monitored blood glucose (SMBG) measurement with continuous glucose monitoring (CGM). This was an observational prospective study. Included in the study were 63 stable, insulin-treated patients with type 2 diabetes. They were instructed to record 2 daily capillary blood glucose readings, pre- and/or postprandial, in a sequential way during 8 consecutive weeks. A CGM system was worn during an additional week. We evaluated the frequency of hypoglycemia using the 8-week SMBG profile and the 1 CGM week. SMBG revealed that 50% of the patients had experienced hypoglycemia. CGM found hypoglycemia in 59% of patients. Significantly higher percentages of hyperglycemic and hypoglycemic episodes were detected by CGM than by capillary blood glucose measurements (61.1% vs. 50.8%; p=0.047) and (3.8% vs. 1.7%; p=0.016); 33% of patients experienced nocturnal hypoglycemia, and 19% of patients who had no data concerning hypoglycemia recorded in the capillary blood glucose diary had experienced hypoglycemia as measured by CGM, and the hypoglycemia occurred mainly during the nocturnal period. In stable well-controlled, insulin-treated patients with type 2 diabetes, CGM showed higher numbers of hypoglycemic events than did SMBG, especially at night. CGM is a useful tool that provides clinically valuable information about glucose control in these patients. Copyright © 2015 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.

  6. Effect of intrapleural oxytocin injection on blood glucose level in rat (rattus norvegicous).

    Science.gov (United States)

    Dezhkam, Y; Dezhkam, N

    2014-01-01

    The effect of Oxytocin on energy metabolism is still question. The aim of the present study was to investigate the effect of exogenous oxytocin injection in different dose and timetable on blood glucose level in rat. In this study 16 adult female rats were divided into 2 groups (Treatment 1(T1) and Treatment 2(T2)). T1 with 8 adult female rats received 0.2 IU/Kg oxytocin via intrapleural (IP) and blood glucose level was tested at 0th, 20th, 40th and 60th min after injection by collecting the blood from jugular vein. In T2 eight female rats received 0.4 IU/kg oxytocin via IP taking blood glucose measure at the same minutes as T1. The experiment tested in three replicates. Blood glucose meter (Model: 3TMSO1G) was used with glucose smart blood glucose monitoring system to the measurement of blood glucose level in rats. Data were analyzed using the GLM procedure of SAS (SAS, version 9) PDIFF was used to compare least square means among treatments adjusting by tukey test. There were hypoglycemic tendency in the changes of the blood glucose level in both T1 and T2, 20th min after injection (88.79 ± 3.28, 68.58 ± 3.63, respectively), while in the remaining subjects (4th and 60th min) blood glucose level increased (115.54 ± 4, 79.7 ± 2.09 and 136.33 ± 5.8, 123.54 ± 0.9, respectively). These results showed that blood glucose level in T1 significantly higher than T2 (p < 0.0001). These in vivo results showed that exogenous oxytocin can be good choice to decrease the blood glucose level very fast.

  7. Vitamin K2 Improves Anxiety and Depression but not Cognition in Rats with Metabolic Syndrome: a Role of Blood Glucose?

    Science.gov (United States)

    Gancheva, Silvia M; Zhelyazkova-Savova, Maria D

    2016-12-01

    The metabolic syndrome is a socially important disorder of energy utilization and storage, recognized as a factor predisposing to the development of depression, anxiety and cognitive impairment in humans. In the present study we examined the effects of vitamin K2 on the behavior of rats with metabolic syndrome and looked for relationships with the effects on blood sugar. Male Wistar rats were divided in four groups: a control group on a regular rat chow, a metabolic syndrome (MS) group fed a high-fat high-fructose diet, a control group treated with vitamin K2 and a MS group treated with vitamin K2. Vitamin K2 was given by gavage. At the end of the study (after 10 weeks) behavioral tests were performed and fasting blood glucose was measured. Anxiety was determined using the social interaction test and depression was assessed by the Porsolt test. Memory effects were estimated by the object recognition test. Correlations between fasting blood glucose and behavioral performance were analyzed. The rats from the MS group had elevated blood glucose. They had anxiety, depression and memory deficit. Vitamin K2 normalized blood glucose, reduced anxiety and depression, but did not improve memory. Time of social interaction (inverse index of anxiety) and memory recognition were negatively correlated with blood glucose in the untreated rats but the immobility time (measure of depression) was not. When vitamin K2-treated rats were added, the correlation of blood glucose with the time of social interaction was kept, but the one with the recognition memory was lost. It might be that the anxiolytic effect of vitamin K2 in this setting is at least partly due to its effects on blood glucose, while the anti-depressant effect is glucose-independent. The present study demonstrated that vitamin K2 prevented the development of anxiety and depression, but did not improve the memory deficit caused by the dietary manipulation in an experimental model of metabolic syndrome. It might be that

  8. Variability of blood pressure and blood glucose during perioperative period for patients with secondary neovascular glaucoma after silicone oil removed in PDR

    Directory of Open Access Journals (Sweden)

    Fu-Lin Gao

    2015-06-01

    Full Text Available AIM:To research blood pressure and blood glucose variability during peroperative period for patients with secondary neovasular glaucoma(NVGafter silicone oil removed in proliferative diabetic retinaopathy(PDR.METHODS: Totally, 271 patients(271 eyesundergone surgery of vitrectomy and silicon-oil tamponade combined with cataract were respective analyzed. Fourteen patients(14 eyeswith secondary NVG after silicon oil removed and randomly controlled group of no NVG according with ages, operation method in the same time were studied. The blood pressure and blood glucose variability during peroperative period was analyzed, and did comparison after excluded contralateral eye. The complications of 271 patients were surveyed in following-up period 1~12mo. The incidence of NVG, the time, blood pressure, blood glucose and glycated hemoglobin(Hbc%variability during peroperative period was statisticed and compared by software of SPSS 11.0.RESULTS: Fourteen eyes(5.2%of 271 cases was with secondary NVG(female: 4 eyes, 28.6%; male: 10 eyes, 71.4%, average ages was 57.07 years(49~68 years. NVG presented in the 107~ 135d after vitrectomy and 7~45d(average 31.78dafter silicon-oil removed. Diabetes mellitus was 10~15(average 13.2a. In NVG group, the variability of blood glucose was 4.0~10.2mmol/L(mean 8.52±3.24mmol/L, variable coefficient was 0.48. In NNVG group, the variability of blood glucose was 5.0~8.2mmol/L(mean 7.22±0.24mmol/L, variable coefficient was 0.43. It was significantly difference in comparison in variable coefficient(PPPPCONCLUSION: There are significant variability on fasting blood glucose, daytime SBP and night DBP during perioperative in PDR patients with secondary NVG. It might be occurred 1wk after silicone oil removal surgery.

  9. Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose.

    Science.gov (United States)

    La Belle, Jeffrey T; Adams, Anngela; Lin, Chi-En; Engelschall, Erica; Pratt, Breanna; Cook, Curtiss B

    2016-07-28

    Tear glucose sensing for diabetes management has long been sought as an alternative to more invasive self-monitoring of blood glucose (SMBG). However, tear glucose sensors were known to have limitations, including correlation issues with blood glucose due to low sample volume, low concentration of glucose in the tear fluid, and evaporation of the tear sample. An engineering design approach to solve these problems led to the development of an integrated device capable of collecting the tear sample from the ocular surface with little to no stress on the eye, with an extremely low limit of detection, broad dynamic range, and rapid detection and analysis of sample. Here we present the development of a prototypical self-monitoring of tear glucose (SMTG) sensor, summarizing bench studies on the enzymes and their specificity, the development of the fluid capture device and its manufacture and performance and results of system testing in an animal study where safety, lag time and tear glucose to blood glucose correlation were assessed.

  10. The Effect of Curry Leaves (Murayya Koenigii L. on Blood Glucose Levels In Alloxan Diabetic Mice (Mus Musculus

    Directory of Open Access Journals (Sweden)

    Fauziah Fauziah

    2014-07-01

    Full Text Available This study was conducted to determine the effect of ethanol extract of curry leaves (Murraya koenigii L. on blood glucose levels in alloxan diabetic mice (Mus musculus. The diabetic conditions were made by giving alloxan 75 mg/kg body weight (BW and the hypoglycemic effects of extract of curry leaves given with various doses.   This study used 24 male mice strain Balb/c in four groups of treatment with six replications, namely the negative control group, the ethanol extract of curry leaf tree 50% mL/10g body weight group, 70% mL/10g body weight group and 90% mL/10g body weight group. The treatment was given orally by using a gastric sonde for 14 days. Blood samples were taken through the sinus caudalis using a scissors. Blood glucose level was measured at 1st , the 8th and the 24th of treatment using blood glucose test strips and Nesco® Multicheck apparatus. Blood glucose data were analyzed by one way ANOVA (Analysis of Variants and followed by Tuckey test at significance level of 5%. The result showed that treatment of ethanol extract of curry leaves (Murraya koenigii at various doses significantly affected the decrease on blood glucose levels of mice (Mus musculus alloxan diabetic.

  11. Evaluation of the Blood-Glucose Reducing Effects of Aqueous ...

    African Journals Online (AJOL)

    Methods: All the aqueous extracts of (Caraway) CA, (Coriander) CO, (Cumin) CU, (Dill) DI and (Fennel) FE were administered at dose levels of 300 mg/kg body weight orally to different groups each containing 5 animals. A control group was also maintained simultaneously and received distilled water orally.Blood samples ...

  12. Liberal Glucose Control in ICU Patients With Diabetes: A Before-and-After Study.

    Science.gov (United States)

    Luethi, Nora; Cioccari, Luca; Biesenbach, Peter; Lucchetta, Luca; Kagaya, Hidetoshi; Morgan, Rhys; Di Muzio, Francesca; Presello, Barbara; Gaafar, Duaa; Hay, Alison; Crisman, Marco; Toohey, Roisin; Russell, Hollie; Glassford, Neil J; Eastwood, Glenn M; Ekinci, Elif I; Deane, Adam M; Bellomo, Rinaldo; Mårtensson, Johan

    2018-03-03

    To assess the feasibility, biochemical efficacy, and safety of liberal versus conventional glucose control in ICU patients with diabetes. Prospective, open-label, sequential period study. A 22-bed mixed ICU of a tertiary hospital in Australia. We compared 350 consecutive patients with diabetes admitted over 15 months who received liberal glucose control with a preintervention control population of 350 consecutive patients with diabetes who received conventional glucose control. Liberal control patients received insulin therapy if glucose was greater than 14 mmol/L (target: 10-14 mmol/L [180-252 mg/dL]). Conventional control patients received insulin therapy if glucose was greater than 10 mmol/L (target: 6-10 mmol/L [108-180 mg/dL]). We assessed separation in blood glucose, insulin requirements, occurrence of hypoglycemia (blood glucose ≤ 3.9 mmol/L [70 mg/dL]), creatinine and white cell count levels, and clinical outcomes. The median (interquartile range) time-weighted average blood glucose concentration was significantly higher in the liberal control group (11.0 mmol/L [8.7-12.0 mmol/L]; 198 mg/dL [157-216 mg/dL]) than in the conventional control group (9.6 mmol/L [8.5-11.0 mmol/L]; 173 mg/dL [153-198 mg/dL]; p liberal control patients (37.7%) and 188 conventional control patients (53.7%) received insulin in ICU (p liberal glucose control, insulin administration, and among patients with hemoglobin A1c greater than or equal to 7%, the prevalence of hypoglycemia was reduced, without negatively affecting serum creatinine, the white cell count response, or other clinical outcomes. (Trial Registration: Australian New Zealand Clinical Trials Registry; ACTRN12615000216516).

  13. Effect of Iranian Honey bee (Apis Mellifera Venom on Blood Glucose and Insulin in Diabetic Rats

    Directory of Open Access Journals (Sweden)

    Seyyedeh Mahbubeh Mousavi

    2012-12-01

    Full Text Available Background: Diabetes is an important disease. This disease is a metabolic disorder characterized by hyperglycemia resulting from perturbation in insulin secretion, insulin action or both. Honey bee venom contains a wide range of polypeptide agents. The principle components of bee venom are mellitin and phospholipase A2. These components increase insulin secretion from the β-cells of pancreas. This study was conducted to show the hypoglycemic effect of honey bee venom on alloxan induced diabetic male rats.Methods: Eighteen adult male rats weighting 200±20 g were placed into 3 randomly groups: control, alloxan monohy­drate-induced diabetic rat and treated group that received honey bee venom daily before their nutrition for four months. Forty eight hours after the last injection, blood was collected from their heart, serum was dissented and blood glucose, insulin, triglyceride and total cholesterol were determined.Results: Glucose serum, triglyceride and total cholesterol level in treated group in comparison with diabetic group was significantly decreased (P< 0.01. On the other hand, using bee venom causes increase in insulin serum in com­parison with diabetic group (P< 0.05.Conclusion: Honeybee venom (apitoxin can be used as therapeutic option to lower blood glucose and lipids in dia­betic rats.

  14. Self-Monitoring of Blood Glucose in Type 2 Diabetes: Recent Studies

    Science.gov (United States)

    Schnell, Oliver; Alawi, Hasan; Battelino, Tadej; Ceriello, Antonio; Diem, Peter; Felton, Anne-Marie; Grzeszczak, Wladyslaw; Harno, Kari; Kempler, Peter; Satman, Ilhan; Vergès, Bruno

    2013-01-01

    The increasing role for structured and personalized self-monitoring of blood glucose (SMBG) in management of type 2 diabetes has been underlined by randomized and prospective clinical trials. These include Structured Testing Program (or STeP), St. Carlos, Role of Self-Monitoring of Blood Glucose and Intensive Education in Patients with Type 2 Diabetes Not Receiving Insulin, and Retrolective Study Self-Monitoring of Blood Glucose and Outcome in Patients with Type 2 Diabetes (or ROSSO)-in-praxi follow-up. The evidence for the benefit of SMBG both in insulin-treated and non-insulin-treated patients with diabetes is also supported by published reviews, meta-analyses, and guidelines. A Cochrane review reported an overall effect of SMBG on glycemic control up to 6 months after initiation, which was considered to subside after 12 months. Particularly, the 12-month analysis has been criticized for the inclusion of a small number of studies and the conclusions drawn. The aim of this article is to review key publications on SMBG and also to put them into perspective with regard to results of the Cochrane review and current aspects of diabetes management. PMID:23567007

  15. [A cohort study on the correlation between birth weight, simple obesity, blood lipids, blood glucose and blood pressure from childhood to adolescence].

    Science.gov (United States)

    Hua, Qi; Tan, Jing; Liu, Zhao-hui; Liu, Rong-kun; Yang, Zheng

    2007-11-01

    To determine the correlation between birth weight and simple obesity, blood lipids, blood glucose and blood pressure from childhood to adolescence. A vertical sectional survey on 193 children aged 7 - 11 years was performed in 1996. A questionnaire consisting of items on environmental factors and lifestyle, physical examination and biochemical assessment was conducted at baseline and the 9th year of follow-up. The incidence of obesity and over-weight in childhood in high (6.1%) and low birth-weight group (5.6%) was higher than that in normal birth-weight group (2.8%), but did not reach statistic significance; The levels of body mass index in adolescence in high and low birth-weight group were significantly higher than that in normal birth-weight group (P = 0.002 and 0.009, respectively), and the incidence of obesity and over-weight in adolescence was significantly higher in high (33.3%) and low birth-weight group (38.9%) than that in normal birth-weight group (16.2%, P = 0.025 and 0.020, respectively). There were no significant differences in the levels of blood glucose, blood lipids and blood pressure between different birth weight groups (all, P > 0.05). Intrauterine growth is linked to physical growth during childhood and adolescence. Nutritional guidance in pregnant phase may help to control the increased prevalence of overweight and obesity in children and adolescent.

  16. The Impact of Opium Consumption on Blood Glucose, Serum Lipids and Blood Pressure, and Related Mechanisms

    Science.gov (United States)

    Najafipour, Hamid; Beik, Ahmad

    2016-01-01

    Aim: Substance abuse has become a universal crisis in our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (78 articles). Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms), but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption. PMID:27790151

  17. The Impact of Opium Consumption on Blood Glucose, Serum Lipids and Blood Pressure, and Related Mechanisms.

    Science.gov (United States)

    Najafipour, Hamid; Beik, Ahmad

    2016-01-01

    Aim: Substance abuse has become a universal crisis in our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (78 articles). Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms), but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption.

  18. The Impact of opium consumption on blood glucose, serum lipids and blood pressure, and related mechanisms

    Directory of Open Access Journals (Sweden)

    Hamid Najafipour

    2016-10-01

    Full Text Available AbstractAim: Substance abuse has become a universal crisisin our modern age. Among illegal substances, opium and its derivatives have been ranked second in terms of usage after cannabis in the world. In many Asian regions, the use of opium enjoys a high social acceptance; hence, some common people and even medical practitioners believe that opium lowers blood glucose and pressure and treat dyslipidemia. How much this belief is scientifically justified? Method: The results of available studies on both humans and animals searched in different search engines up to mid-2016 were integrated (77 articles. Upon the findings we try to offer a more transparent picture of the effects of opium on the mentioned factors along with the probable underlying mechanisms of its action. Results: Taken together, a variety of evidences suggest that the consumption of opium has no scientific justification for amendment of these biochemical variables. The mechanisms proposed so far for the action of opium in the three above disorders are summarized at the end of the article. Short term effects seems to be mostly mediated through central nervous system (neural and hormonal mechanisms, but long term effects are often due to the structural and functional alterations in some body organs. Conclusion: Although opium may temporarily reduce blood pressure, but it increases blood glucose and most of blood lipids. Moreover its long term use has negative impacts and thus it aggravates diabetes, dyslipidemia and hypertension. Accordingly, it is necessary to inform societies about the potential disadvantages of unauthorized opium consumption.

  19. Investigation on the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Ma Zhongwei

    2005-01-01

    Objective: To explore the correlationship between plasma homocysteine and blood glucose, insulin levels in patients with type 2 diabetes mellitus. Methods: Plasma homocysteine (with ELISA), blood glucose (with hexokinase method) and insulin (with RIA) levels were measured in 66 patients with type 2 diabetes mellitus as well as in 35 controls. Results: Plasma homocysteine levels in the diabetic patients (n=66) were significantly higher than those in controls (P<0.01), especially in those patients complicated with nephropathy (n=32). The homocysteine levels were positively correlated with those of blood glucose and insulin (r=0.3515, r=0.3486, both P<0.01). Conclusion: Plasma homocysteine is an independent risk factor for vascular diseases. The levels of plasma cysteine are significantly increased in patients with type 2 diabetes mellitus, especially in those complicated with nephropathy. Therefore, monitoring of plasma homocysteine level changes is clinically useful. (authors)

  20. Self-monitoring of blood glucose: Advice for providers and patients.

    Science.gov (United States)

    Knapp, Shannon; Manroa, Pooja; Doshi, Krupa

    2016-05-01

    Self-monitoring of blood glucose is a critical element in diabetes management. Providers must determine if and when patients are to perform glucose self-monitoring, set blood glucose targets, and help patients to interpret the results. Patients have a variety of continually evolving meters, supplies, and technology from which to choose. Making sense of these expectations and options is perhaps the greatest challenge for providers and patients. Working together, healthcare providers and certified diabetes educators can ensure that people with diabetes get the most out of self-monitoring of blood glucose. Copyright © 2016 Cleveland Clinic.

  1. The accuracy of blood glucose testing by children.

    Science.gov (United States)

    Strumph, P S; Odoroff, C L; Amatruda, J M

    1988-04-01

    While studies have evaluated the accuracy of adult patients and health personnel in reading various glucose oxidase impregnated strips to estimate blood glucose, there are no studies exclusively evaluating the accuracy of children with diabetes reading their own strips as compared to a staff member, and meter to meter variability in reading these strips. We evaluated the accuracy of reading chemstrip bG by children at a summer camp. The children's visual readings of their own strips were compared to the visual reading of a single staff member. A total of 356 Chemstrip bG's were visually read by diabetic children and a single trained staff member at a summer camp for diabetics. The strips were then analyzed by two Accu-Chek bG meters. Intermachine variability was found to be negligible over the entire bG range. For the purposes of this study, we define accurate visual readings as those within +/- 15 percent of the meter reading of a given strip. At low bG values (40-79 mg/dl), accuracy by children and staff is low, with underestimating occurring in 39 percent of staff readings and 57 percent of children's readings. At intermediate bG values (120-239 mg/dl) readings are more accurate, especially when read by the staff, with misreadings occurring in only 16-19 percent of the strips. At high bG values (240-399 mg/dl), accuracy by children is decreased, with underestimation 500 percent more often than staff. We conclude that children are less accurate at reading Chemstrip bG than a trained staff member (51% versus 33% misreading), especially at the upper and lower ranges of bG values when visual readings are least accurate, and the need for therapeutic intervention is the greatest.

  2. Artificial neural networks based controller for glucose monitoring during clamp test.

    Directory of Open Access Journals (Sweden)

    Merav Catalogna

    Full Text Available Insulin resistance (IR is one of the most widespread health problems in modern times. The gold standard for quantification of IR is the hyperinsulinemic-euglycemic glucose clamp technique. During the test, a regulated glucose infusion is delivered intravenously to maintain a constant blood glucose concentration. Current control algorithms for regulating this glucose infusion are based on feedback control. These models require frequent sampling of blood, and can only partly capture the complexity associated with regulation of glucose. Here we present an improved clamp control algorithm which is motivated by the stochastic nature of glucose kinetics, while using the minimal need in blood samples required for evaluation of IR. A glucose pump control algorithm, based on artificial neural networks model was developed. The system was trained with a data base collected from 62 rat model experiments, using a back-propagation Levenberg-Marquardt optimization. Genetic algorithm was used to optimize network topology and learning features. The predictive value of the proposed algorithm during the temporal period of interest was significantly improved relative to a feedback control applied at an equivalent low sampling interval. Robustness to noise analysis demonstrates the applicability of the algorithm in realistic situations.

  3. Levels of Blood Glucose and Total Protein of Repeat Breeding Dairy Cows From Daerah Istimewa Yogyakarta

    Directory of Open Access Journals (Sweden)

    Dhasia Ramandani

    2015-11-01

    breeding case had lower blood glucose and total protein plasm concentrations than that of the normal. The average concentrations of blood glucose and total protein plasm were 48.58±6.675 mg/dl and 6.815±821 g/dl, respectively.

  4. Quantify Glucose Level in Freshly Diabetic's Blood by Terahertz Time-Domain Spectroscopy

    Science.gov (United States)

    Chen, Hua; Chen, Xiaofeng; Ma, Shihua; Wu, Xiumei; Yang, Wenxing; Zhang, Weifeng; Li, Xiao

    2018-04-01

    We demonstrate the capability of terahertz (THz) time-domain spectroscopy (TDS) to quantify glucose level in ex vivo freshly diabetic's blood. By investigating the THz spectra of different human blood, we find out THz absorption coefficients reflect a high sensitivity to the glucose level in blood. With a quantitative analysis of 70 patients, we demonstrate that the THz absorption coefficients and the blood glucose levels perform a linear relationship. A comparative experiment between THz measurement and glucometers is also conducted with another 20 blood samples, and the results confirm that the relative error is as less as 15%. Our ex vivo human blood study indicates that THz technique has great potential application to diagnose blood glucose level in clinical practice.

  5. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  6. The Effects of on Blood Glucose Values are Greater than those of Dietary Changes Alone

    Directory of Open Access Journals (Sweden)

    Ashley N. Hoehn

    2012-01-01

    Full Text Available Eighteen type II diabetics (9 women and 9 men participated in a 12-week trial that consisted of 2 parts, a 3-week control phase followed by a 9-week experimental phase where half of the subjects received 1000 mg of Cinnamomum cassia while the other half received 1000 mg of a placebo pill. All of the subjects that were in the cinnamon group had a statistically significant decrease in their blood sugar levels with a P -value of 3.915 × 10 -10 . The subjects in the cinnamon group had an average overall decrease in their blood sugar levels of about 30 mg/dL, which is comparable to oral medications available for diabetes. All subjects were educated on appropriate diabetic diets and maintained that diet for the entire 12 week study. Greater decreases in blood glucose values were observed in patients using the cinnamon compared to those using the dietary changes alone.

  7. Evaluation of the Capillary Blood Glucose Self-monitoring Program

    Directory of Open Access Journals (Sweden)

    Mariana Cristina Augusto

    2014-10-01

    Full Text Available OBJECTIVE: to evaluate the structure, process and results of the Capillary Blood Glucose Self-monitoring Program in a Brazilian city.METHOD: epidemiological, cross-sectional study. The methodological framework of Donabedian was used to construct indicators of structure, process and outcome. A random sample (n = 288 of users enrolled and 96 health professionals who worked in the program was studied. Two questionnaires were used that were constructed for this study, one for professionals and one for users, both containing data for the evaluation of structure, process and outcome. Anthropometric measures and laboratory results were collected by consulting the patients' health records. The analysis involved descriptive statistics.RESULTS: most of the professionals were not qualified to work in the program and were not knowledgeable about the set of criteria for patient registration. None of the patients received complete and correct orientations about the program and the percentage with skills to perform conducts autonomously was 10%. As regards the result indicators, 86.4% of the patients and 81.3% of the professionals evaluated the program positively.CONCLUSION: the evaluation indicators designed revealed that one of the main objectives of the program, self-care skills, has not been achieved.

  8. Neural pathways that control the glucose counterregulatory response

    Directory of Open Access Journals (Sweden)

    Tony eVerberne

    2014-02-01

    Full Text Available Glucose is an essential metabolic substrate for all bodily tissues. The brain depends particularly on a constant supply of glucose to satisfy its energy demands. Fortunately, a complex physiological system has evolved to keep blood glucose at a constant level. The consequences of poor glucose homeostasis are well-known: hyperglycaemia associated with uncontrolled diabetes can lead to cardiovascular disease, neuropathy and nephropathy, while hypoglycaemia can lead to convulsions, loss of consciousness, coma and even death. The glucose counterregulatory response involves detection of declining plasma glucose levels and secretion of several hormones including glucagon, adrenaline, cortisol and growth hormone to orchestrate the recovery from hypoglycaemia. Low blood glucose leads to a low brain glucose level that is detected by glucose-sensing neurons located in several brain regions such as the ventromedial hypothalamus, the perifornical region of the lateral hypothalamus, the arcuate nucleus and in several hindbrain regions. This review will describe the importance of the glucose counterregulatory system and what is known of the neurocircuitry that underpins it.

  9. [Gestational diabetes mellitus: importance of blood glucose monitoring].

    Science.gov (United States)

    Flores Le-Roux, Juana A; Benaiges Boix, David; Pedro-Botet, Juan

    2013-01-01

    Gestational diabetes mellitus (GDM) is common during pregnancy, and is frequently associated with maternal and perinatal complications. Intensive treatment of hyperglycaemia during pregnancy has been shown to reduce perinatal morbidity. In women with pregestational type 1 or 2 diabetes, hyperglycaemia during labour and delivery is an important factor in the development of neonatal hypoglycaemia. There are no generally accepted recommendations for women with GDM. Recent studies evaluating patients with GDM show that peripartum glucose control can be achieved in these women without the need for insulin use in the majority of cases. Hyperglycaemia during labour is not related with treatment established during pregnancy but rather with non-compliance of endocrinological follow-up. Factors such as ethnic origin, neonatal hypoxaemia, and large for gestational age seem to play an important role in the development of neonatal hypoglycaemia. Copyright © 2012 Elsevier España, S.L. and SEA. All rights reserved.

  10. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects

    DEFF Research Database (Denmark)

    Vahidi, O; Kwok, K E; Gopaluni, R B

    2016-01-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main...... variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data...... obtained during oral glucose tolerance test and isoglycemic intravenous glucose infusion test from both type 2 diabetic and healthy subjects to estimate the model parameters and to validate the model results. The estimation of model parameters is accomplished through solving a nonlinear optimization...

  11. Blood glucose and insulin levels in normal subjects following a meal with and without added sugar beet pulp.

    Science.gov (United States)

    Tredger, J; Sheard, C; Marks, V

    1981-09-01

    The fibrous components of sugar beet pulp were investigated to determine whether they would reduce the post-prandial rise in blood glucose and plasma insulin levels when incorporated into a mixed meal. On two separate occasions six healthy volunteers were given either a control meal (providing 86 g carbohydrate) or an identical meal with the addition of 20 g sugar beet pulp (test meal). Blood glucose and plasma insulin levels were measured post-prandially for 3 hours. There was no significant difference between the mean blood glucose of plasma insulin curves at any time after the two meals. Since viscous types of dietary fibers are known to be effective in reducing post-prandial hyperglycaemia and insulinaemia, it would seem that either the physio-chemical nature of the fibre or the procedure employed to extract the sugar renders the particulate fibre inactive.

  12. Changes in blood glucose and insulin responses to intravenous glucose tolerance tests and blood biochemical values in adult female Japanese black bears (Ursus thibetanus japonicus).

    Science.gov (United States)

    Kamine, Akari; Shimozuru, Michito; Shibata, Haruki; Tsubota, Toshio

    2012-02-01

    The metabolic mechanisms to circannual changes in body mass of bears have yet to be elucidated. We hypothesized that the Japanese black bear (Ursus thibetanus japonicus) has a metabolic mechanism that efficiently converts carbohydrates into body fat by altering insulin sensitivity during the hyperphagic stage before hibernation. To test this hypothesis, we investigated the changes in blood biochemical values and glucose and insulin responses to intravenous glucose tolerance tests (IVGTT) during the active season (August, early and late November). Four, adult, female bears (5-17 years old) were anesthetized with 6 mg/kg TZ (tiletamine HCl and zolazepam HCl) in combination with 0.1 mg/kg acepromazine maleate. The bears were injected intravenously with glucose (0.5 g/kg of body mass), and blood samples were obtained before, at, and intermittently after glucose injection. The basal triglycerides concentration decreased significantly with increase in body mass from August to November. Basal levels of plasma glucose and serum insulin concentrations were not significantly different among groups. The results of IVGTT demonstrated the increased peripheral insulin sensitivity and glucose tolerance in early November. In contrast, peripheral insulin resistance was indicated by the exaggerated insulin response in late November. Our findings suggest that bears shift their glucose and lipid metabolism from the stage of normal activity to the hyperphagic stage in which they show lipogenic-predominant metabolism and accelerate glucose uptake by increasing the peripheral insulin sensitivity.

  13. Self-monitoring of blood glucose: a prerequisite for diabetes management in outcome trials.

    Science.gov (United States)

    Schnell, Oliver; Hanefeld, Markolf; Monnier, Louis

    2014-05-01

    Evidence for the value of self-monitoring of blood glucose (SMBG) with regard to the achievement of treatment targets, detection of postprandial glucose excursions, and minimization of glycemic variability is increasing. In large clinical trials, SMBG is a key component for the optimization of diabetes treatment in insulin-treated diabetes. It also plays an essential role in outcome studies. However, details of SMBG use in both the methods and results sections of clinical articles are frequently scarce. Also, a discussion of the SMBG data and its impact on insulin therapy is valuable. In the recently completed Outcome Reduction with an Initial Glargine INtervention (ORIGIN) trial, SMBG was described in detail and insulin titration was largely driven by SMBG. Both aspects largely contributed to the fact that near-normal control was achieved over a long-term period. © 2014 Diabetes Technology Society.

  14. ASVCP guidelines: quality assurance for portable blood glucose meter (glucometer) use in veterinary medicine.

    Science.gov (United States)

    Gerber, Karen L; Freeman, Kathleen P

    2016-03-01

    Portable blood glucose meters (PBGM, glucometers) are a convenient, cost effective, and quick means to assess patient blood glucose concentration. The number of commercially available PBGM is constantly increasing, making it challenging to determine whether certain glucometers may have benefits over others for veterinary testing. The challenge in selection of an appropriate glucometer from a quality perspective is compounded by the variety of analytic methods used to quantify glucose concentrations and disparate statistical analysis in many published studies. These guidelines were developed as part of the ASVCP QALS committee response to establish recommendations to improve the quality of testing using point-of-care testing (POCT) handheld and benchtop devices in veterinary medicine. They are intended for clinical pathologists and laboratory professionals to provide them with background knowledge and specific recommendations for quality assurance (QA) and quality control (QC), and to serve as a resource to assist the provision of advice to veterinarians and technicians to improve the quality of results obtained when using PBGM. These guidelines are not intended to be all-inclusive; rather they provide a minimum standard for management of PBGM in the veterinary setting. © 2016 American Society for Veterinary Clinical Pathology.

  15. SPCE based glucose sensor employing novel thermostable glucose dehydrogenase, FADGDH: blood glucose measurement with 150nL sample in one second.

    Science.gov (United States)

    Yamaoka, Hideaki; Sode, Koji

    2007-01-01

    Self-monitoring of blood glucose (SMBG) is an important component of the modern therapy for diabetes mellitus. Thanks to the current progress in electronics and sensor fabrication technology, both the time and the blood sample volume required for the measurement have decreased drastically. However, devices that work with an even smaller sample volume and a shorter measurement time are in demand. A disposable glucose sensor that works with an ultra-small sample volume was developed employing the novel thermostable glucose-dehydrogenase (FADGDH) complex composed of a catalytic subunit, an electron transfer subunit (cytochrome c), and a small subunit. The electrode is a screen-printed carbon electrode (SPCE), and hexaammineruthenium (III) chloride (Ru complex) is utilized as the electron mediator. A disposable enzyme sensor was constructed by depositing the FADGDH complex and Ru complex onto the SPCE, and the sensor performance was evaluated. Whole-blood glucose can be measured within 1 sec using this enzyme sensor and a 150-nL whole-blood sample, with high precision (>0.99br>) and high reproducibility (CV) within the glucose concentration range of 0-533 mg/dL. The sensor reading was stable for more than 60 days even at 70 degrees C. The simplicity of the construction and the high precision of this FADGDH-based glucose biosensor makes it an alternative to previously reported commercially available glucose sensors. Especially the sample volume of 150 nL and the 1-sec measurement time are the highest specifications in the world for currently available glucose sensors designed for the SMBG.

  16. Effects of pre-meal and post-meal mild physical exercises on blood glucose level

    OpenAIRE

    中島, 英洋; 吉江, 弘樹; 中澤, 翔太; 赤土, 知佳; 海尻, 真里; 松尾, 加澄美; 吉岡, 由佳里; 吉崎, 結城

    2010-01-01

     The aim of this study is to compare changes in blood glucose level in response to a mild physical exercise for 25 minutes either in the fasted state or 30 minutes after a standardized meal.  Seven healthy university students (2 males and 5 females, 21 years of age) were studied in a crossover design to compare three conditions: no exercise (control), pre-meal and post-meal exercises.  The three trials conducted on separate days consisted of a rest day when the subjects consumed the standardi...

  17. Improving blood sugar control during critical illness: a cohort study.

    Science.gov (United States)

    O'Connor, Enda; Tragen, David; Fahey, Paul; Robinson, Michael; Cremasco, Theresa

    2010-03-01

    The aim of this study is to compare blood sugar control and safety profile of nurse-titrated and medically ordered glucose-insulin regimens. We conducted a retrospective cohort study in a 9-bedded regional intensive care unit (ICU) in Queensland, Australia. Seventy critically ill patients requiring one-on-one nursing and intravenous insulin were included. In the nursing group, the ICU nurse decided initial and ongoing insulin infusion rates and glucose measurement frequency. The medical group had a traditional insulin sliding scale prescription. Thirty-seven patients in the nursing group had 1949 glucose measurements. Thirty-three patients in the medical group had 2118 measurements. Mean blood sugar levels (+/-SD) were 8.33 +/- 2.34 and 8.78 +/- 2.74 in nursing and medical groups (P control is safe, effective, and results in high compliance with a glucose target range. Crown Copyright 2010. Published by Elsevier Inc. All rights reserved.

  18. Glucose excursions and glycaemic control during Ramadan fasting in diabetic patients: insights from continuous glucose monitoring (CGM).

    Science.gov (United States)

    Lessan, N; Hannoun, Z; Hasan, H; Barakat, M T

    2015-02-01

    Ramadan fasting represents a major shift in meal timing and content for practicing Muslims. This study used continuous glucose monitoring (CGM) to assess changes in markers of glycaemic excursions during Ramadan fasting to investigate the short-term safety of this practice in different groups of patients with diabetes. A total of 63 subjects (56 with diabetes, seven healthy volunteers; 39 male, 24 female) had CGM performed during, before and after Ramadan fasting. Mean CGM curves were constructed for each group for these periods that were then used to calculate indicators of glucose control and excursions. Post hoc data analyses included comparisons of different medication categories (metformin/no medication, gliptin, sulphonylurea and insulin). Medication changes during Ramadan followed American Diabetes Association guidelines. Among patients with diabetes, there was a significant difference in mean CGM curve during Ramadan, with a slow fall during fasting hours followed by a rapid rise in glucose level after the sunset meal (iftar). The magnitude of this excursion was greatest in the insulin-treated group, followed by the sulphonylurea-treated group. Markers of control deteriorated in a small number (n=3) of patients. Overall, whether fasting or non-fasting, subjects showed no statistically significant changes in mean interstitial glucose (IG), mean amplitude of glycaemic excursion (MAGE), high and low blood glucose indices (HBGI/LBGI), and number of glucose excursions and rate of hypoglycaemia. The main change in glycaemic control with Ramadan fasting in patients with diabetes is in the pattern of excursions. Ramadan fasting caused neither overall deterioration nor improvement in the majority of patients with good baseline glucose control. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Study of the Effect of Garlic on Serum Lipids and Blood Glucose Levels in Type 2 Diabetic Patients

    Directory of Open Access Journals (Sweden)

    M Afkhami - Ardekani

    2005-04-01

    Full Text Available Introduction: Hyperlipidemia and diabetes are common risk factors for ischemic heart disease, which is the main cause of mortality in diabetic patients. Strict control of blood glucose and other risk factors in diabetics has led to prevention of complications. Garlic has received particular attention for control of blood glucose and decrease in blood lipid levels. At present, several studies have been carried out in order to prove advantages of garlic. Methods: In this study, effects of garsin (a derivative of garlic present in our country on serum lipids and blood glucose levels in diabetes mellitus type 2 patients was observed. Forty-five type 2 diabetics who had hyperlipidemia were selected. These patients were kept on treatment with 3 tablets of Garsin / day for 4 weeks. Serum lipids and blood glucose levels were measured prior to and at the end of treatment. Results: Relationship between sex and response to treatment in this study was meaningful, such that Gsarsin led to decrease in LDL-C and increase in HDL in females. Conclusion: Therefore, Garsin can be used as an adjunct to treatment in diabetes type 2 patients with hyperlipidemia.

  20. Controlling your high blood pressure

    Science.gov (United States)

    Controlling hypertension ... when you wake up. For people with very high blood pressure, this is when they are most at risk ... 2014 evidence-based guideline for the management of high blood pressure in adults: report from the panel members appointed ...

  1. The relationships between blood pressure, blood glucose, and bone mineral density in postmenopausal Turkish women.

    Science.gov (United States)

    Cakmak, Huseyin Altug; Cakmak, Burcu Dincgez; Yumru, Ayse Ender; Aslan, Serkan; Enhos, Asim; Kalkan, Ali Kemal; Coskun, Ebru Inci; Acikgoz, Abdullah Serdar; Karatas, Suat

    2015-01-01

    Hypertension, diabetes mellitus, and osteoporosis are important comorbidities commonly seen in postmenopausal women. The aim of the present study was to investigate the relationships between blood pressure, blood glucose, and bone mineral density (BMD) in postmenopausal Turkish women. In this cross-sectional study, 270 consecutive patients who were admitted to an outpatient clinic with vasomotor symptoms and/or at least 1 year of amenorrhea were included. The patients were categorized into three groups according to their blood pressure and metabolic status as follows: normotensive, hypertensive nondiabetics, and hypertensive diabetics. The T- and z-scores of the proximal femur and lumbar vertebrae were measured with the dual-energy X-ray absorptiometry method to assess the BMD of the study groups. Lumbar vertebral T-scores (P<0.001), lumbar vertebral z-scores (P<0.003), and proximal femoral T-scores (P<0.001) were demonstrated to be significantly lower in the hypertensive diabetic group compared to the hypertensive nondiabetic and normotensive groups. Systolic blood pressure was significantly inversely correlated with lumbar vertebral T-scores (r=-0.382; P=0.001), lumbar vertebral z-scores (r=-0.290; P=0.001), and proximal femoral T-scores (r=-0.340; P=0.001). Moreover, diastolic blood pressure was significantly inversely correlated with lumbar vertebral T-scores (r=-0.318; P=0.001), lumbar vertebral z-scores (r=-0.340; P=0.001), and proximal femoral T-scores (r=-0.304; P=0.001). Hypertension (odds ratio [OR]: 2.541, 95% confidence interval [CI]: 1.46-3.48, P=0.003), diabetes mellitus (OR: 2.136, 95% CI: 1.254-3.678, P=0.006), and age (OR: 1.069, 95% CI: 1.007-1.163, P=0.022) were found to be significant independent predictors of osteopenia in a multivariate analysis, after adjusting for other risk parameters. The present study is the first to evaluate the relationships between blood pressure, blood glucose, and BMD in postmenopausal Turkish women. Moreover, both

  2. The experiences of diabetics on self-monitoring of blood glucose: a qualitative metasynthesis.

    Science.gov (United States)

    Chen, Chen-Mei; Chang Yeh, Mei

    2015-03-01

    To interpret, describe and analyse the results of various qualitative studies and comprehensively elucidate the self-monitoring of blood glucose experiences of diabetic patients, and to make recommendations based on these findings for clinical practices. Patients exhibited both positive and negative perceptions towards the self-monitoring of blood glucose. Numerous recent qualitative studies have explored the self-monitoring of blood glucose experiences of diabetic patients; however, no integrated results have been provided. Qualitative metasynthesis. A systematic literature search of English and Chinese databases was undertaken, covering the period between January 2004 and April 2014. The following databases were searched: CINAHL, PubMed, MEDLINE, Cochrane Library, Airiti library and PsycInfo. Seven studies were assessed in the final analysis; the Joanna Briggs Institute Qualitative Assessment and Review Instrument was used to evaluate these studies. The self-monitoring experiences of patients with diabetes were divided into five themes: perceived disease severity, effects on daily life, lifestyle adjustments after becoming aware of blood glucose levels, determining the meaning of self-monitoring, and the differences between diabetic patients who use and do not use insulin. Individual differences in blood glucose self-monitoring vary widely among diabetic patients. These differences result from personal cognition and feelings concerning blood glucose monitoring. Insights into and discussions regarding the self-monitoring of blood glucose experiences of diabetic patients enable health care professionals to understand the factors that influence the intentions of patients to perform self-monitoring of blood glucose and facilitate establishing customised self-monitoring of blood glucose treatment plans. Health care professionals must adopt flexible and individualised criteria to determine patient cognitive misconceptions, understand negative emotional reactions and

  3. A comprehensive compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects.

    Science.gov (United States)

    Vahidi, O; Kwok, K E; Gopaluni, R B; Knop, F K

    2016-09-01

    We have expanded a former compartmental model of blood glucose regulation for healthy and type 2 diabetic subjects. The former model was a detailed physiological model which considered the interactions of three substances, glucose, insulin and glucagon on regulating the blood sugar. The main drawback of the former model was its restriction on the route of glucose entrance to the body which was limited to the intravenous glucose injection. To handle the oral glucose intake, we have added a model of glucose absorption in the gastrointestinal tract to the former model to address the resultant variations of blood glucose concentrations following an oral glucose intake. Another model representing the incretins production in the gastrointestinal tract along with their hormonal effects on boosting pancreatic insulin production is also added to the former model. We have used two sets of clinical data obtained during oral glucose tolerance test and isoglycemic intravenous glucose infusion test from both type 2 diabetic and healthy subjects to estimate the model parameters and to validate the model results. The estimation of model parameters is accomplished through solving a nonlinear optimization problem. The results show acceptable precision of the estimated model parameters and demonstrate the capability of the model in accurate prediction of the body response during the clinical studies.

  4. Self-monitoring of blood glucose in noninsulin-treated type 2 diabetes: an overview

    Directory of Open Access Journals (Sweden)

    Nanne Kleefstra

    2009-09-01

    Full Text Available Nanne Kleefstra1, Johanna Hortensius1, Kornelis JJ van Hateren1, Susan JJ Logtenberg1, Sebastiaan T Houweling2, Rijk OB Gans3, Henk JG Bilo11Diabetes Centre, Isala Clinics, Zwolle, The Netherlands; 2Langerhans Medical Research Group, The Netherlands; 3Department of Internal Medicine, University Medical Center Groningen, Groningen, The NetherlandsIntroduction: The effectiveness of self-monitoring of blood glucose (SMBG in noninsulin-treated patients with type 2 diabetes (T2DM remains unclear. We aimed to review the trials investigating the effects of SMBG in this population.Methods: Medline was searched until June 29, 2009. Randomized controlled trials (RCTs of at least 12 weeks’ duration were included. Data on the following aspects were gathered: patient and study characteristics, effects on HbA1c, quality of life and treatment satisfaction, and methodological quality.Results: The search revealed 9 original RCTs. These studies were very heterogeneous, and 5 were classified as of high quality. The studies with the best methodology did not show an effect of SMBG on HbA1c, the studies with the worst methodological quality did. Two out of the 4 studies that assessed quality of life showed a significant change in favor of the control group, 1 study showed a significant change in favor of SMBG.Discussion and conclusion: We found an inverse relation between study quality and efficacy of SMBG. At this moment, there is no basis for general use of SMBG in noninsulin-treated T2DM patients.Keywords: blood glucose self-monitoring, diabetes mellitus, type 2, blood glucose, hemoglobin A, glycosylated

  5. Dominio cultural del autocuidado en diabeticos tipo 2 con y sin control glucémico en México Domínio cultural do autocuidado em pacientes com diabetes tipo 2 com e sem controle glicêmico no México Cultural domain of self-care in type 2 diabetes patients with and without blood glucose control in Mexico

    Directory of Open Access Journals (Sweden)

    Ana L Salcedo-Rocha

    2008-04-01

    Full Text Available OBJETIVO: Analisar los principales elementos relacionados con el dominio cultural del autocuidado de la salud, entre pacientes con diabetes tipo 2 con y sin controle glucémico. MÉTODOS: Estudio descriptivo en 57 diabéticos controlados y 76 sin control glucémico, con promedio de 60 años de edad en una clínica del Seguro Social en México en 2003. Se aplicaron técnicas de antropología cognitiva de listas libres y cuestionario estructurado para obtener modelo semántico y promedio de conocimiento cultural a seis preguntas sobre su padecimiento por análisis de consenso. RESULTADOS: Los datos sociodemográficos de ambos grupos no mostraron diferencias significativas. Todos los modelos de respuesta comparados presentaron estructuras semánticas similares, con excepción a: "Qué se entiende como ejercicio" (pOBJETIVO: Analisar os principais elementos relacionados ao domínio cultural do autocuidado da saúde entre pacientes com diabetes tipo 2, com ou sem controle glicêmico. MÉTODOS: Estudo descritivo com 57 diabéticos com controle glicêmico e 76 sem controle, com média de 60 anos de idade em clínica de seguro social no México, em 2003. Foram aplicadas técnicas de antropologia cognitiva de listas livres e questionário estruturado para obter modelo semântico e média de conhecimento cultural a seis perguntas sobre seu adoecimento, por análise de consenso das respostas. RESULTADOS: Os dados sociodemográficos de ambos os grupos mostraram diferenças significativas. Todos os modelos de resposta comparados apresentaram estruturas semânticas similares, à exceção de: "o que se entende por exercício" (pOBJECTIVE: To analyze the main elements related with the cultural domain of self-health care in type 2 diabetes patients with and without good blood glucose control. METHODS: Descriptive study comprising diabetes patients, 57 with and 76 without good blood glucose control, with an average age of 60 years, who attended a Social Security

  6. A Meta-Analysis of Blood Glucose Effects on Human Decision Making

    DEFF Research Database (Denmark)

    Orquin, Jacob L.; Kurzban, Robert

    2016-01-01

    The academic and public interest in blood glucose and its relationship to decision making has been increasing over the last decade. To investigate and evaluate competing theories about this relationship, we conducted a psychometric meta-analysis on the effect of blood glucose on decision making. We...... and willingness to work when a situation is food related, but decrease willingness to pay and work in all other situations. Low levels of blood glucose increase the future discount rate for food; that is, decision makers become more impatient, and to a lesser extent increase the future discount rate for money...

  7. Four grams of glucose

    OpenAIRE

    Wasserman, David H.

    2008-01-01

    Four grams of glucose circulates in the blood of a person weighing 70 kg. This glucose is critical for normal function in many cell types. In accordance with the importance of these 4 g of glucose, a sophisticated control system is in place to maintain blood glucose constant. Our focus has been on the mechanisms by which the flux of glucose from liver to blood and from blood to skeletal muscle is regulated. The body has a remarkable capacity to satisfy the nutritional need for glucose, while ...

  8. Internet-Based Contingency Management to Improve Adherence with Blood Glucose Testing Recommendations for Teens with Type 1 Diabetes

    Science.gov (United States)

    Raiff, Bethany R.; Dallery, Jesse

    2010-01-01

    The current study used Internet-based contingency management (CM) to increase adherence with blood glucose testing to at least 4 times daily. Four teens diagnosed with Type 1 diabetes earned vouchers for submitting blood glucose testing videos over a Web site. Participants submitted a mean of 1.7 and 3.1 blood glucose tests per day during the 2…

  9. Geniposide regulates glucose-stimulated insulin secretion possibly through controlling glucose metabolism in INS-1 cells.

    Directory of Open Access Journals (Sweden)

    Jianhui Liu

    Full Text Available Glucose-stimulated insulin secretion (GSIS is essential to the control of metabolic fuel homeostasis. The impairment of GSIS is a key element of β-cell failure and one of causes of type 2 diabetes mellitus (T2DM. Although the KATP channel-dependent mechanism of GSIS has been broadly accepted for several decades, it does not fully describe the effects of glucose on insulin secretion. Emerging evidence has suggested that other mechanisms are involved. The present study demonstrated that geniposide enhanced GSIS in response to the stimulation of low or moderately high concentrations of glucose, and promoted glucose uptake and intracellular ATP levels in INS-1 cells. However, in the presence of a high concentration of glucose, geniposide exerted a contrary role on both GSIS and glucose uptake and metabolism. Furthermore, geniposide improved the impairment of GSIS in INS-1 cells challenged with a high concentration of glucose. Further experiments showed that geniposide modulated pyruvate carboxylase expression and the production of intermediates of glucose metabolism. The data collectively suggest that geniposide has potential to prevent or improve the impairment of insulin secretion in β-cells challenged with high concentrations of glucose, likely through pyruvate carboxylase mediated glucose metabolism in β-cells.

  10. The effects of celery leaf (apium graveolens L.) treatment on blood glucose and insulin levels in elderly pre-diabetics.

    Science.gov (United States)

    Yusni, Yusni; Zufry, Hendra; Meutia, Firdalena; Sucipto, Krishna W

    2018-02-01

    To analyze the effect of celery leaf extract on blood glucose and plasma insulin levels in elderly pre-diabetics. Methods: This study was conducted between March and November 2014 at the Faculty of Medicine, Syiah Kuala University, Banda Aceh, Indonesia. A quasi-experimental pretest-posttest with a control group was conducted with elderly pre-diabetic volunteers. The subjects included 16 elderly pre-diabetics older than 60 (6 males and 10 females). The subjects were randomly divided into 2 groups: a control group (placebo-treated) and a treatment group (celery-treated). The treatment consisted of celery leaf extract capsules at the dose of 250 mg, 3 times per day (morning, afternoon and evening), 30 minutes before a meal, for 12 days. Data analysis was performed using the t-test (p less than 0.05). Results: There was a significant decrease in pre-prandial plasma glucose levels (p=0.01) and post-prandial plasma glucose levels (p=0.00), but no significant increase in plasma insulin levels (p=0.15) after celery leaf treatment in elderly pre-diabetics. Conclusion: Celery was effective at reducing blood glucose levels, but there was a lack of association between blood glucose levels and plasma insulin levels in elderly pre-diabetics.

  11. Blood Glucose and Insulin Concentrations after Octreotide Administration in Horses With Insulin Dysregulation.

    Science.gov (United States)

    Frank, N; Hermida, P; Sanchez-Londoño, A; Singh, R; Gradil, C M; Uricchio, C K

    2017-07-01

    Octreotide is a somatostatin analog that suppresses insulin secretion. We hypothesized that octreotide would suppress insulin concentrations in horses and that normal (N) horses and those with insulin dysregulation (ID) would differ significantly in their plasma glucose and insulin responses to administration of octreotide. Twelve horses, N = 5, ID = 7. Prospective study. An oral sugar test was performed to assign horses to N and ID groups. Octreotide (1.0 μg/kg IV) was then administered, and blood was collected at 0, 5, 10, 15, 20, 25, 30, 45, 60, 75, and 90 minute, and 2, 3, 4, 6, 8, 12, and 24 hour for measurement of glucose and insulin concentrations. Area under the curve (AUC) values were calculated. Mean AUC values for glucose and insulin did not differ between normal (n = 5) and ID (n = 7) groups after octreotide injection. Significant time (P insulin concentrations. A group × time interaction (P = .091) was detected for insulin concentrations after administration of octreotide, but the group (P = .33) effect was not significant. Octreotide suppresses insulin secretion, resulting in hyperglycemia, and then concentrations increase above baseline as glycemic control is restored. Our hypothesis that octreotide causes insulin concentrations to decrease in horses was supported, but differences between N and ID groups did not reach statistical significance when blood glucose and insulin responses were compared. The utility of an octreotide response test remains to be determined. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. Perspectives of patients with type 1 or insulintreated type 2 diabetes on self-monitoring of blood glucose : a qualitative study

    NARCIS (Netherlands)

    Hortensius, Johanna; Kars, Marijke C.; Wierenga, Willem S.; Kleefstra, Nanne; Bilo, Henk J. G.; van der Bijl, Jaap J.

    2012-01-01

    Background: Self-monitoring of blood glucose (SMBG), including self-regulation, is an important tool to achieve good glycemic control. However, many patients measure their glucose concentrations less often than is recommended. This study investigates patients' perspectives of SMBG and all relevant

  13. Non-invasive blood glucose monitor based on spectroscopy using a smartphone.

    Science.gov (United States)

    Dantu, Vishnu; Vempati, Jagannadh; Srivilliputhur, Srinivasan

    2014-01-01

    Development of a novel method for non-invasive measurement of blood glucose concentration using smartphone is discussed. Our research work has three major contributions to society and science. First, we modified and extended the Beer-Lambert's law in physics to accommodate for multiple wavelengths. This extension can aid researchers who wish to perform optical spectroscopy. Second, we successfully developed a creative and non-invasive way for diabetic patients to measure glucose levels via a smartphone. Researchers and chemists can now use their smartphones to determine the absorbance and, therefore, concentration of a chemical. Third, we created an inexpensive way to perform optical spectroscopy by using a smartphone. Monitoring blood glucose using a smartphone application that simply uses equipment already available on smartphones will improve the lives of diabetic patients who can continuously check their blood glucose levels while avoiding the current inconvenient, unhygienic, and costly invasive glucose meters.

  14. Regional brain glucose metabolism and blood flow in streptozocin-induced diabetic rats

    International Nuclear Information System (INIS)

    Jakobsen, J.; Nedergaard, M.; Aarslew-Jensen, M.; Diemer, N.H.

    1990-01-01

    Brain regional glucose metabolism and regional blood flow were measured from autoradiographs by the uptake of [ 3 H]-2-deoxy-D-glucose and [ 14 C]iodoantipyrine in streptozocin-induced diabetic (STZ-D) rats. After 2 days of diabetes, glucose metabolism in the neocortex, basal ganglia, and white matter increased by 34, 37, and 8%, respectively, whereas blood flow was unchanged. After 4 mo, glucose metabolism in the same three regions was decreased by 32, 43, and 60%. This reduction was paralleled by a statistically nonsignificant reduction in blood flow in neocortex and basal ganglia. It is suggested that the decrease of brain glucose metabolism in STZ-D reflects increased ketone body oxidation and reduction of electrochemical work

  15. [Effects of probiotics on blood glucose levels and clinical outcomes in patients with severe craniocerebral trauma].

    Science.gov (United States)

    Tan, Min; Lu, Xiao-lan; Duan, Jun-wei; Peng, Hua; Zhu, Jing-ci

    2013-10-01

    To investigate the effects of probiotics on blood glucose levels and clinical outcomes in patients suffering from severe craniocerebral trauma. A prospective randomized control study was conducted. Fifty-two severe craniocerebral trauma patients admitted to intensive care unit (ICU) were randomized into experimental or control group (each n=26). All patients received conventional treatment according to Guidelines for the Clinical Management of Traumatic Brain Injury and enteral nutrition within 24-48 hours after admission through nasogastric tube. In addition, the experimental group received 1×10(9) bacteria of viable probiotics (Golden Bifid, 3.5 g for 3 times per day) per day for 21 days. The fasting blood glucose levels were determined in the morning before intervention and on day 4, 8, 15, 21 after intervention. Amount of insulin used during hospitalization, Glasgow coma scale (GCS) scores, length of ICU stay, and 28-day mortality rate were studied. There was no difference in term of the blood glucose levels between two groups before intervention. On day 8 and 15 after intervention, significantly lower levels of fasting blood glucose were observed in the experimental group compared with those of the control group (8 days: 6.6±1.2 mmol/L vs. 8.0±2.7 mmol/L, t=-2.500, P=0.017; 15 days: 6.1±1.4 mmol/L vs. 7.2±2.2 mmol/L, t=-2.269, P=0.028). There were significantly less patients treated with insulin or shorter days of insulin therapy in experimental group than in control group [19.2% (5/26) vs. 46.2% (12/26), χ(2)=4.282, P=0.039; 1.6±0.9 vs. 4.3±3.1, t=-2.698, P=0.017]. The length of ICU stay was significantly shorter in the experimental group than that of control group (6.8±3.8 days vs. 10.7±7.3 days, t=-2.123, P=0.034). No significant differences were found about the GCS scores (before intervention: 6.3±1.0 vs. 6.4±1.0, t=-0.408, P=0.685; 21 days after intervention: 10.1±4.0 vs. 9.6±4.3, t=0.435, P=0.665) and 28-day mortality rate [11.5% (3/26) vs

  16. Increasing Blood Glucose Variability Is a Precursor of Sepsis and Mortality in Burned Patients

    OpenAIRE

    Pisarchik, Alexander N.; Pochepen, Olga N.; Pisarchyk, Liudmila A.

    2012-01-01

    High glycemic variability, rather than a mean glucose level, is an important factor associated with sepsis and hospital mortality in critically ill patients. In this retrospective study we analyze the blood glucose data of 172 nondiabetic patients 18-60 yrs old with second and third-degree burns of total body surface area greater than 30% and 5%, respectively, admitted to ICU in 2004-2008. The analysis identified significant association of increasing daily glucose excursion (DELTA) accompanie...

  17. Within-Individual Hematocrit Variations and Self-Monitoring of Blood Glucose

    OpenAIRE

    Topping, Kaila A.; Cembrowski, George S.

    2013-01-01

    Many self-monitoring of blood glucose (SMBG) systems have generated artefactually increased glucose results in low-hematocrit patients (e.g., intensive care unit and renal failure patients); conversely, these devices could produce artefactually decreased glucose results in high-hematocrit patients (e.g., neonates). The introduction of hematocrit-independent SMBG systems permits more accurate testing in anemic or polycythemic individuals. In this issue of Journal of Diabetes Science and Techno...

  18. Interstitial Glucose and Lactate Levels Are Inversely Correlated With the Body Mass Index: Need for In Vivo Calibration of Glucose Sensor Results With Blood Values in Obese Patients.

    Science.gov (United States)

    Enderle, Barbara; Moser, Isabella; Kannan, Cecil; Schwab, Karl Otfried; Urban, Gerald

    2018-03-01

    Continuously measured glucose and lactate levels in interstitial fluid (ISF) may markedly differ from their respective blood levels. Combining microdialysis with a bioanalytical microsystem, the interstitial glucose and lactate concentrations of eight male volunteers with different body mass index (BMI) were monitored during a 2-fold glucose tolerance test over the period of three hours. Significant correlations were found between abdominally measured sensor results and reference measurements ( R 2 = .967 for glucose and R 2 = .936 for lactate, P 34 kg/m 2 showed abdominally as well as the antebrachially significantly reduced tissue glucose values compared to blood glucose values ( P < .001). A very good correlation between abdominally measured sensor results and the results of the reference method verified the reliability of the BioMEMS. The abdominally measured glucose level in ISF decreased significantly with increasing BMI. Therefore, an in vivo calibration of glucose levels in ISF with blood levels seems to be necessary especially in markedly obese subjects.

  19. Glucose increases interleukin-12 gene expression and production in stimulated peripheral blood mononuclear cells of type 2 diabetes patients

    Directory of Open Access Journals (Sweden)

    Chien-Ming Chu

    2014-10-01

    Full Text Available Background: Lipopolysaccharide (LPS-stimulated peripheral blood mononuclear cells (PBMCs of type 2 diabetes patients produce more interleukin (IL-12 under glucose treatment. The aim of this study was to determine whether increased IL-12 response in hyperglycemic LPS-stimulated PBMCs is due to increased gene expression or osmolarity. Methods: LPS-stimulated PBMCs of 13 type 2 diabetes patients and 8 healthy controls were used for culture in the presence or absence of glucose or mannitol for 24 h. The IL-12 gene expressions of PBMCs and IL-12 protein levels in supernatants were evaluated. Results: After 24 h, the stimulated PBMCs of diabetes patients expressed more IL-12 mRNA and produced more IL-12 protein following glucose treatment than those without glucose treatment and with mannitol treatment. Stimulated PBMCs of controls did not express more IL-12 mRNA and produce more IL-12 protein following glucose treatment than those without glucose treatment and with mannitol treatment. Conclusions: Glucose increases the IL-12 production in stimulated PBMCs of diabetes patients through increased IL-12 gene expression.

  20. The new functions of the gut in the control of glucose homeostasis.

    Science.gov (United States)

    Mithieux, Gilles

    2005-07-01

    It has become clear during the past few years that the intestine is more than a digestive tract. In addition to its role as a subtle endocrine organ, its participation in endogenous glucose production, a property so far believed to be restricted to the liver and kidney, has been emphasized. The role of the gut in the regulation of glucose homeostasis has received further experimental accreditation from both animal and human studies. In relation to the molecular mechanisms of control of glucose production the potential regulatory role of glutaminase and glycerokinase has been suggested from studies of fasting, and the transcription of the glucose-6 phosphatase gene has been specified in an intestinal context. Furthermore, two newly described metabolic pathways accounting for the transepithelial transport of glucose have received further support: from the intestinal lumen to inside the enterocyte, involving a translocation of the glucose transporter Glut2 to the apical membrane, and from inside the enterocyte into the blood, involving glucose 6-phosphatase and independent of Glut2. The new knowledge regarding the control of glucose, glutamine, and glycerol metabolisms in the small intestine should be of interest to those who care for diabetic or septic patients, or are involved in nutrition research in humans. They should also be of importance in the knowledge of inherited genetic deficiencies, such as glycogen storage disease type 1 (Von Gierke disease) and the Fanconi-Bickel and glucose-galactose malabsorption syndromes.

  1. Mediterranean diet reduces 24-hour ambulatory blood pressure, blood glucose, and lipids: one-year randomized, clinical trial.

    Science.gov (United States)

    Doménech, Mónica; Roman, Pilar; Lapetra, José; García de la Corte, Francisco J; Sala-Vila, Aleix; de la Torre, Rafael; Corella, Dolores; Salas-Salvadó, Jordi; Ruiz-Gutiérrez, Valentina; Lamuela-Raventós, Rosa-María; Toledo, Estefania; Estruch, Ramón; Coca, Antonio; Ros, Emilio

    2014-07-01

    The PREvención con DIeta MEDiterránea (PREDIMED) trial showed that Mediterranean diets (MedDiets) supplemented with either extravirgin olive oil or nuts reduced cardiovascular events, particularly stroke, compared with a control, lower fat diet. The mechanisms of cardiovascular protection remain unclear. We evaluated the 1-year effects of supplemented MedDiets on 24-hour ambulatory blood pressure (BP), blood glucose, and lipids. Randomized, parallel-design, controlled trial was conducted in 2 PREDIMED sites. Diets were ad libitum, and no advice on increasing physical activity or reducing sodium intake was given. Participants were 235 subjects (56.5% women; mean age, 66.5 years) at high cardiovascular risk (85.4% with hypertension). Adjusted changes from baseline in mean systolic BP were -2.3 (95% confidence interval [CI], -4.0 to -0.5) mm Hg and -2.6 (95% CI, -4.3 to -0.9) mm Hg in the MedDiets with olive oil and the MedDiets with nuts, respectively, and 1.7 (95% CI, -0.1 to 3.5) mm Hg in the control group (Pthe MedDiets with olive oil, MedDiets with nuts, and control diet, respectively; those of total cholesterol were -11.3, -13.6, and -4.4 mg/dL (P=0.043), respectively. In high-risk individuals, most with treated hypertension, MedDiets supplemented with extravirgin olive oil or nuts reduced 24-hour ambulatory BP, total cholesterol, and fasting glucose. http://www.clinicaltrials.gov. Unique identifier: ISRCTN35739639. © 2014 American Heart Association, Inc.

  2. The associations of a marine diet with plasma lipids, blood glucose, blood pressure and obesity among the inuit in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, P; Pedersen, H S; Mulvad, G

    2000-01-01

    OBJECTIVE: To analyse the associations between the intake of fish and marine mammals and risk factors for cardiovascular disease, ie lipid profile, fasting blood glucose, blood pressure and obesity, in a population whose average consumption of n-3 fatty acids is high compared with Western countries...

  3. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    The aim of study is to determine whether glucose pump test (GPT) is used for surveillance of native AV fistulas by using Doppler US as reference. Methods: In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US and GPT. For GPT, glucose was infused to 16 mL/min by ...

  4. Control of hepatic glucose output by glucagon and insulin in the intact dog.

    Science.gov (United States)

    Cherrington, A D; Chiasson, J L; Liljenquist, J E; Lacy, W W; Park, C R

    1978-01-01

    The regulation of hepatic glucose production by glucagon and insulin has been studied in the intact dog. An attempt has been made to evaluate the role of basal physiological concentrations of the hormones in the regulation of glycogenolysis and gluconeogenesis. Somatostatin was infused continuously into postabsorptive dogs to inhibit the secretion of both glucagon and insulin. Either or both hormones were then replaced intraportally by continuous infusion as desired. The main observations were as follows. (1) When both hormones were simultaneously replaced for periods up to 4.5h, plasma insulin and glucagon concentrations, total glucose output (glycogenolysis plus gluconeogenesis), glucose utilization and the plasma glucose concentration closely matched the same parameters in 0.9% NaCl-infused controls. (2) When glucagon alone was infused, thereby creating a selective insulin deficiency, glucose output (primarily glycogenolysis) rapidly increased by as much as threefold. Glycogenolytic glucose production then fell off progressively and returned to the control value within 4h. The gluconeogenic conversion of [14C]alanine and [14C]lactate into [14C]glucose was stimulated markedly and increased progressively throughout the test period. Glucagon therefore converted the liver from an organ largely dependent on glycogenolysis for glucose production to one heavily dependent on gluconeogenesis. The potent inhibitory effect of basal insulin on postabsorptive glucose output was also clearly apparent. (3) When insulin alone was infused, thereby creating a selective glucagon deficiency, glucose output (glycogenolysis) fell abruptly by about 30% and remained decreased. Gluconeogenesis also decreased (20%) after the selective removal of both insulin and glucagon, but it only remained suppressed for 1h. The low glucose output led to a modest fall in the blood glucose concentration. Thus glucagon plays an important role in maintaining basal glucose production. (4) When insulin was

  5. Haematological Indices, Blood glucose levels and lipid profile of rats ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    2015-11-11

    dose ... hypoglycemic effect in rats, no negative effect was observed on lipid profile. KEY WORDS: Tartrazine E102; glucose; haematological; cholesterol; triacylglycerol ... sulfanilic acid and aminopyrazolone. The pyrazolone ...

  6. Effects of blood glucose level on FDG uptake by liver: a FDG-PET/CT study

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Kazuo, E-mail: kkubota@cpost.plala.or.j [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Watanabe, Hiroshige; Murata, Yuji [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan); Yukihiro, Masashi; Ito, Kimiteru; Morooka, Miyako; Minamimoto, Ryogo [Division of Nuclear Medicine, Department of Radiology, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Hori, Ai [Department of Epidemiology and International Health, Research Institute, National Center for Global Health and Medicine, Tokyo 162-8655 (Japan); Shibuya, Hitoshi [Department of Radiology, Faculty of Medicine, Tokyo Medical and Dental University, Tokyo 113-8519 (Japan)

    2011-04-15

    In FDG-PET for abdominal malignancy, the liver may be assumed as an internal standard for grading abnormal FDG uptake both in early images and in delayed images. However, physiological variables of FDG uptake by the liver, especially the effects of blood glucose level, have not yet been elucidated. Methods: FDG-PET studies of 70 patients examined at 50 to 70 min after injection (60{+-}10 min: early images) and of 68 patients examined at 80 to 100 min after injection (90{+-}10 min: delayed images) were analyzed for liver FDG uptake. Patients having lesions in the liver, spleen and pancreas; patients having bulk tumor in other areas; and patients early after chemotherapy or radiotherapy were excluded; also, patients with blood glucose level over 125 mg/dl were excluded. Results: Mean standardized uptake value (SUV) of the liver, blood glucose level and sex showed no significant differences between early images and delayed images. However, liver SUV in the delayed image showed a larger variation than that in the early image and showed significant correlation to blood glucose level. The partial correlation coefficient between liver SUV and blood glucose level in the delayed image with adjustment for sex and age was 0.73 (P<.0001). Multivariate regression coefficient (95% confidence interval) of blood glucose was 0.017 (0.013-0.021). Conclusion: Blood glucose level is an important factor affecting the normal liver FDG uptake in nondiabetic patients. In the case of higher glucose level, liver FDG uptake is elevated especially in the delayed image. This may be due to the fact that the liver is the key organ responsible for glucose metabolism through gluconeogenesis and glycogen storage.

  7. Effect of blood glucose level on 18F-FDG PET/CT imaging

    International Nuclear Information System (INIS)

    Tan Haibo; Lin Xiangtong; Guan Yihui; Zhao Jun; Zuo Chuantao; Hua Fengchun; Tang Wenying

    2008-01-01

    Objective: The aim of this study was to investigate the effect of blood glucose level on the image quality of 18 F-fluorodeoxyglucose (FDG) PET/CT imaging. Methods: Eighty patients referred to the authors' department for routine whole-body 18 F-FDG PET/CT check up were recruited into this study. The patients were classified into 9 groups according to their blood glucose level: normal group avg and SUV max ) of liver on different slices. SPSS 12.0 was used to analyse the data. Results: (1) There were significant differences among the 9 groups in image quality scores and image noises (all P avg and SUV max : 0.60 and 0.33, P<0.05). Conclusions: The higher the blood glucose level, the worse the image quality. When the blood glucose level is more than or equal to 12.0 mmol/L, the image quality will significantly degrade. (authors)

  8. 75 FR 2549 - Clinical Accuracy Requirements for Point of Care Blood Glucose Meters; Public Meeting; Request...

    Science.gov (United States)

    2010-01-15

    .... When registering, you must provide your name, title, company or organization (if applicable), address... and clinical use of blood glucose meters, to share ideas on the challenges associated with their use...

  9. Blood Glucose and Cholesterol Concentrations in a Mediterranean Rural Population of Andros Island, Greece

    Directory of Open Access Journals (Sweden)

    Konstantinos T Tsaousis

    2014-01-01

    Conclusions: The present study confirms that dyslipidemia and high blood glucose levels are prevalent among the rural populations of Greece and therefore informative campaigns and structured screening programs are required to promote preventive health care.

  10. Assessing portable blood glucose meters for clinical use in cats in the United Kingdom.

    Science.gov (United States)

    Dobromylskyj, M J; Sparkes, A H

    2010-09-18

    The aims of this study were to evaluate six portable blood glucose meters for use in cats in a clinical setting and to identify potential sources of inaccuracy such as the effect of glucose concentration and haematocrit. Excess fluorinated whole-blood samples were obtained and were tested using the six meters and a reference laboratory method. Bland-Altman plots were constructed and an error grid analysis was performed, using a grid adapted in this study for diabetic cats. Error grids are a clinically oriented non-parametric approach to blood glucose data, and are designed to determine whether differences between glucometer and laboratory readings are clinically significant. All the meters studied had the potential to under- or overestimate blood glucose levels to varying degrees throughout the glycaemic range. This variation was not consistent enough to be predictable and correctable. The study failed to demonstrate any link between haematocrit and difference between laboratory and glucometer readings.

  11. Dimethylarginines, blood glucose, and C-reactive protein in patients with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Aurélie Gudjoncik

    2016-04-01

    Conclusion: Our study showed that in patients with acute MI, SDMA, and only weakly ADMA, are associated with admission blood glucose, beyond traditional dimethylarginine determinants and may therefore have biological activity beyond renal function.

  12. Practical approaches for self-monitoring of blood glucose: an Asia-Pacific perspective.

    Science.gov (United States)

    Chowdhury, Subhankar; Ji, Linong; Suwanwalaikorn, Sompongse; Yu, Neng-Chun; Tan, Eng Kiat

    2015-03-01

    Comprehensive glycemic control is necessary to improve outcomes and avoid complications in individuals with diabetes. Self-monitoring of blood glucose (SMBG) is a key enabler of glycemic assessment, providing real-time information that complements HbA1c monitoring and supports treatment optimization. However, SMBG is under-utilized by patients and physicians within the Asia-Pacific region, because of barriers such as the cost of monitoring supplies, lack of diabetes self-management skills, or concerns about the reliability of blood glucose readings. Practice recommendations in international and regional guidelines vary widely, and may not be detailed or specific enough to guide SMBG use effectively. This contributes to uncertainty among patients and physicians about how best to utilize this tool: when and how often to test, and what action(s) to take in response to high or low readings. In developing a practical SMBG regimen, the first step is to determine the recommended SMBG frequency and intensity needed to support the chosen treatment regimen. If there are practical obstacles to monitoring, such as affordability or access, physicians should identify the most important aspects of glycemic control to target for individual patients, and modify monitoring patterns accordingly. This consensus paper proposes a selection of structured, flexible SMBG patterns that can be tailored to the clinical, educational, behavioral, and financial requirements of individuals with diabetes.

  13. Biochemical relationships between bone turnover markers and blood glucose in patients with type 2 diabetes mellitus.

    Science.gov (United States)

    Hussein, Rasha M

    2017-11-01

    Patients with type 2 diabetes mellitus develop many complications including osteopenia, which is associated with high fracture risk. Osteocalcin is a non collagenous protein derived from the osteoblasts. Recently, it was found that osteocalcin enhances the pancreatic beta cell proliferation, insulin secretion and protection against type 2 diabetes. Investigation of the association of serum osteocalcin and other bone turnover markers with blood glucose level and diabetes mellitus duration in type 2 diabetic patients. Twenty diagnosed type 2 diabetic patients together with 20 healthy controls were enrolled in this study. Serum osteocalcin, alkaline phosphatase activity and calcium concentrations were measured by commercial ELISA kits. The results showed that type 2 diabetic patients exhibited a significantly lower serum osteocalcin and calcium (p=0.0001 and 0.002 respectively) and a higher alkaline phosphatase (p=0.008) compared to the controls. Multiple linear regression analysis revealed that serum osteocalcin was inversely associated with fasting blood glucose and Diabetes Mellitus duration (β=- 0.018; p=0.007 and β=- 0.085; p=0.014 respectively) in Type 2 diabetic patients. In addition, alkaline phosphatase was positively associated (β=0.828; p=0.015) while serum calcium was negatively associated (β=- 0.046; p=0.048) with Diabetes Mellitus duration. These results refer to the strong association between diabetes and bone turnover markers and call for monitoring of diabetes-associated osteopenia in type 2 diabetic patients. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  14. Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

    Science.gov (United States)

    De Pretto, Lucas Ramos; Yoshimura, Tania Mateus; Ribeiro, Martha Simões; Zanardi de Freitas, Anderson

    2016-08-01

    As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration.

  15. THE EFFECTIVENES OF ETANOL EXTRACT, PARTITION N-HEKSANA, AND CROMATHOGRAPHY FRACTION OF MOMORDICA CHARANTIA L. TO LOWER BLOOD GLUCOSE LEVEL

    Directory of Open Access Journals (Sweden)

    Ni Luh Putu Kusuma Clara Dewinda

    2017-08-01

    Full Text Available This study aims to determine the effectiveness of the ethanol extract, partition n-hexane, and chromatography fractions Momordica charantia L. in lowering blood glucose levels in experimental diabetic male rats.  This study used 25 male rats were divided into five treatment groups P0 (negative control, P1 (positive control, P2 (ethanol extract, P3 (partition n-hexane, and P4 (chromatographic fraction the variable observed glucose levels blood for 21 days. Blood glucose levels were analyzed on days -1, 0, 4, 11, 18. The bill, which is used in the form of a completely randomized design (CRD. The data obtained and analyzed by using Split in Time. The results showed of giving chromatographic fractions bitter melon 50 mg / kg body weight can reduce blood glucose levels in hyperglycemic rats better than the ethanol extract 200 mg / kg body weight and partition n-hexane 50 mg / kg body weight.

  16. Opto-acoustic monitoring of blood optical properties as a function of glucose concentration

    Science.gov (United States)

    Bednov, Andrey A.; Savateeva, Elena V.; Oraevsky, Alexander A.

    2003-06-01

    Time-resolved optoacoustic (OA) method was employed to measure changes in glucose concentration in the whole and diluted blood. An increase of the glucose level in tissue results in a corresponding decrease of optical scattering. Relative changes in tissue optical scattering can be obtained by measuring the effective optical attenuation coefficient, μeff by exponential fitting of the time-resolved optoacoustic profiles. Glucose effects in blood have been investigated using the forward mode of OA detection performed in the visible (at the wavelength, λ=532 nm) and near infrared (λ=1064 nm) spectral ranges. In our previous set of experiments, the OA studies performed in model media in vitro and biological tissue (sclera) in vivo demonstrated gradual reduction of optical scattering with the increase in glucose level. The present study has supported our previous observations. However, one novel effect was observed comprised of a transient increase in μeff during the first 5-10 minutes after injection of glucose. This phenomenon may be explained by changes in erythrocytes shape and size as a result of their adaptation to hyperglycemic conditions. Our observation was supported by light microscopy images of red blood cells under normal and hyperglycemic conditions. With glucose concentration changing rapidly (osmotic shock), any small reduction in ´eff due to the glucose-induced decrease of relative refraction index of blood, can be compensated or even overwhelmed by the increase in ´eff due to erythrocyte shrinkage and/or spherulation. Further cellular adaptation to glucose make erythrocytes return to their normal shape of biconcave disks about 7-μm in diameter. The kinetics of the effective optical attenuation was studies in response to glucose injection in order to better understand the mechanisms of erythrocyte adaptation to osmotic shock and to determine the time course of RBCs adaptation to various glucose concentrations. Finally, Mannitol as alternative

  17. Clinical implication of blood glucose monitoring in general dental offices: the Ehime Dental Diabetes Study

    OpenAIRE

    Harase, Tadahiro; Nishida, Wataru; Hamakawa, Tomohiro; Hino, Satoshi; Shigematsu, Kenji; Kobayashi, Satoru; Sako, Hirofumi; Ito, Shirou; Murakami, Hajime; Nishida, Kei; Inoue, Hiroshi; Fujisawa, Masahito; Yoshizu, Hiroshi; Kawamura, Ryoichi; Takata, Yasunori

    2015-01-01

    Objective We examined whether general dentists can contribute to the detection of patients with undiagnosed diabetes and prediabetes by monitoring blood glucose in dental clinics. Research design and methods A total of 716 patients who visited clinics for dental treatment were enrolled and classified into 3 groups (mild, moderate, and severe) according to Kornman's criteria for periodontitis. The correlations between the casual blood glucose level, presence or absence of the history of diabet...

  18. The Health Behavior Schedule-II for Diabetes Predicts Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Frank, Maxwell T.; Cho, Sungkun; Heiby, Elaine M.; Lee, Chun-I; Lahtela, Adrienne L.

    2006-01-01

    The Health Behavior Schedule-II for Diabetes (HBS-IID) is a 27-item questionnaire that was evaluated as a predictor of self-monitoring of blood glucose (SMBG). The HBS-IID was completed by 96 adults with Type 2 diabetes. Recent glycosylated hemoglobin HbA1c and fasting blood glucose results were taken from participants' medical records. Only 31.3%…

  19. Effects of exposure to electromagnetic field radiation (EMFR generated by activated mobile phones on fasting blood glucose

    Directory of Open Access Journals (Sweden)

    Sultan Ayoub Meo

    2013-04-01

    Full Text Available Objective: Extensive use of mobile phones has been accompanied by a common public debate about possible adverse effects on human health. No study has been published so far to establish any association between the fastest growing innovation of mobile phone and fasting blood glucose. The aim was to determine the effects of exposure to electromagnetic field radiation generated by mobile phones on fasting blood glucose in Wistar Albino rats. Materials and Methods: 40 Male Albino rats (Wistar Strain were divided into 5 equally numerous groups. Group A served as the control one, group B received mobile phone radiation for less than 15 min/day, group C: 15-30 min/day, group D: 31-45 min/day, and group E: 46-60 min/day for a total period of 3 months. Fasting blood glucose was determined by using Spectrophotometer and serum insulin by Enzyme-linked Immunosorbent Assay (ELISA. The Homeostatic Model (HOMA-B was applied for the assessment of β-cell function and (HOMA-IR for resistance to insulin. Results: Wister Albino rats exposed to mobile phone radiation for longer than 15 min a day for a total period of 3 months had significantly higher fasting blood glucose (p < 0.015 and serum insulin (p < 0.01 compared to the control group. HOMA-IR for insulin resistance was significantly increased (p < 0.003 in the groups that were exposed for 15-30 and 46-60 min/day compared to the control rats. Conclusion: The results of the present study show an association between long-term exposure to activated mobile phones and increase in fasting blood glucose and serum insulin in Albino rats.

  20. Evaluation of random plasma glucose for assessment of glycaemic control in type 2 diabetes mellitus.

    Science.gov (United States)

    Ain, Qurratul; Latif, Atif; Jaffar, Syed Raza; Ijaz, Aamir

    2017-09-01

    To evaluate the accuracy of random plasma glucose in outpatients with type 2 diabetes mellitus for assessing glycaemic control. This comparative, cross-sectional study was conducted at the chemical pathology department of PNS Shifa Hospital, Karachi, from August 2015 to March 2016, and comprised data of subjects with type 2 diabetes mellitus who reported for evaluation of glycaemic control in non-fasting state. All blood samples were analysed for random plasma glucose and glycated haemoglobin. Random plasma glucose was compared as an index test with glycated haemoglobin considering it as reference standard at a value of less than 7% for good glycaemic control. SPSS 20 was used for data analysis. Of the 222 subjects, 93(42%) had good glycaemic control. Random plasma glucose showed strong positive correlation with glycated haemoglobin (p=0.000).Area under curve for random plasma glucose as determined by plotting receiver operating characteristic curve against glycated haemoglobin value of 7% was 0.89 (95% confidence interval: 0.849-0.930). Random plasma glucose at cut-off value of 150 mg/dl was most efficient for ruling out poor glycaemic control among patients with type 2 diabetes mellitus with 90.7% sensitivity and69.9% specificity and Youden's index of 0.606. Random plasma glucose may be used to reflect glycaemic control in adults with type 2 diabetes mellitus in areas where glycated haemoglobin is not feasible.

  1. The validity of monitoring the control of diabetes with random blood ...

    African Journals Online (AJOL)

    2013-07-13

    Jul 13, 2013 ... Scientific Letter: The validity of monitoring the control of diabetes with random blood glucose testing. 579. Vol 55 No 6. SA Fam Pract 2013. Introduction. One of the important clinical decisions that must be made when caring for a person with diabetes is to determine if his or her blood glucose is well ...

  2. Waist circumference as a predictor for blood glucose levels in adults

    Directory of Open Access Journals (Sweden)

    Shinta L Hardiman

    2016-02-01

    Full Text Available Anthropometric indexes such as body mass index (BMI, waist circumference (WC, hip ciucumference (HC, and waist–hip ratio (WHR, are all useful anthropometric measurements to provide important information on blood glucose concentrations. The aim of this study was to determine different anthropometric measurements, in particular BMI, waist circumference, hip circumference and waist-to-hip ratio, in their ability to predict the blood glucose levels in men and women 40 to 60. A cross-sectional study was conducted on a sample of 44 men and 127 women aged 40 to 50 who lived in Cipete Selatan subdistrict, South Jakarta. Blood glucose levels was assessed and anthropometric measurements comprising BMI, WC, HC, WHR were collected. Multiple linear regression analysis was used to determine the best predictor for blood glucose levels. The study showed that the prevalence of DM type 2 was 25.7% and the prevalence was higher in men (40.9% compared to women (23.5%. The significant predictive variables in the simple regression analysis were age and waist circumference. Multiple linear regression showed that after adjustment for age, WC was positively associated with blood glucose levels. Standardized a value was 0.172 (p=0.026. WC predict blood glucose levels, beyond that explained by traditional diabetic risk factors and BMI. These findings provide support for the recommendation that WC be a routine measure for identification of diabetes mellitus type 2 in men and women aged 40 to 60 years.

  3. [Self-monitoring of blood glucose in France: data from a national survey].

    Science.gov (United States)

    Guerci, Bruno; Benhamou, Pierre-Yves; Durain, Danièle; Bahloul, Amar; Jeanbat, Viviane; Detournay, Bruno

    2017-04-27

    Objectives: To describe Self-Monitoring of Blood Glucose (SMBG) practices in France in patients with type 1 (T1DM) or type 2 (T2DM) diabetes, by estimating the proportion of patients performing SMBG at the recommended testing frequency and the proportion of patients complying with the current quality control guidelines on SMBG. Materials and methods: National cross-sectional study conducted in 238 pharmacies. A questionnaire was completed with adult diabetic patients buying SMBG devices or reagent strips for themselves, using a blood glucose meter for at least 6 months, treated with insulin or sulfonylurea/glinides ± other oral hypoglycaemic agents (HA). Results: Data from 449 patients were analysed: 85 T1DM and 121 T2DM patients treated by multiple basal-bolus injections ± HA (Group A and Group B), 123 T2DM patients treated by basal insulin ± HA (Group C), 102 patients treated by other insulin regimens ± HA (Group D) and 120 T2DM patients treated by sulfonylurea / glinides without insulin ± other HA (Group E). The recommended test frequency was observed by 29.8%, 36.4%, 61.8% and 69.2% of patients in Group A, Group B, Group C, and Group E, respectively. The quality of self-monitoring was insufficient in terms of device cleaning, storage conditions/expiry date of reagent strips, or use of control solutions. Patients displayed a limited capacity to take decisions in relation to their SMBG results (Group A: 56.5%, Group B: 70.2%, Group C: 49.2%, Group E: 36.0%) and limited knowledge about their glucose targets (Group A: 81%, Group B: 80.5%, Group C: 68.6%, Group E: 73.7%). Conclusion: SMBG use and compliance with quality guidelines must be improved, but healthcare professionals and patients must also focus their efforts on education to interpret SMBG results.

  4. Effect of insulin degludec versus insulin glargine on glycemic control and daily fasting blood glucose variability in insulin-naïve Japanese patients with type 2 diabetes: I'D GOT trial.

    Science.gov (United States)

    Aso, Yoshimasa; Suzuki, Kunihiro; Chiba, Yasuko; Sato, Minoru; Fujita, Nobuya; Takada, Yoshihisa; Murano, Shunichi; Kuroda, Hisamoto

    2017-08-01

    Insulin degludec (IDeg) is an ultra-long-acting insulin that has a smooth time/action profile over more than 42h. The present study compared the effects of IDeg and insulin glargine (IGlar) on HbA1c reduction and on within-subject day-to-day variability of fasting blood glucose (FBG) in insulin-naïve patients with type 2 diabetes. Eligible patients were randomly allocated at a 3:1 ratio to receive once-daily IDeg (n=31) or IGlar (n=12). Both basal insulins were administered before breakfast and titrated to achieve a target FBG type 2 diabetes. The day-to-day variation of FBG was smaller in patients receiving IDeg. Copyright © 2017. Published by Elsevier B.V.

  5. Low blood glucose precipitates spike-and-wave activity in genetically predisposed animals.

    Science.gov (United States)

    Reid, Christopher A; Kim, Tae Hwan; Berkovic, Samuel F; Petrou, Steven

    2011-01-01

    Absence epilepsies are common, with a major genetic contribution to etiology. Certain environmental factors can influence absence occurrence but a complete understanding of absence precipitation is lacking. Herein we investigate if lowering blood glucose increases spike-wave activity in mouse models with varying seizure susceptibility. Three mouse models were used: an absence seizure model based on the knockin of a human GABA(A) γ2(R43Q) mutation (DBA(R43Q)), the spike-wave discharge (SWD)-prone DBA/2J strain, and the seizure resistant C57Bl/6 strain. Electrocorticography (ECoG) studies were recorded to determine SWDs during hypoglycemia induced by insulin or overnight fasting. An insulin-mediated reduction in blood glucose levels to 4 mm (c.a. 40% reduction) was sufficient to double SWD occurrence in the DBA(R43Q) model and in the SWD-prone DBA/2J mouse strain. Larger reductions in blood glucose further increased SWDs in both these models. However, even with large reductions in blood glucose, no discharges were observed in the seizure-resistant C57Bl/6 mouse strain. Injection of glucose reversed the impact of insulin on SWDs in the DBA(R43Q) model, supporting a reduction in blood glucose as the modulating influence. Overnight fasting reduced blood glucose levels to 4.5 mm (c.a. 35% reduction) and, like insulin, caused a doubling in occurrence of SWDs. Low blood glucose can precipitate SWDs in genetically predisposed animal models and should be considered as a potential environmental risk factor in patients with absence epilepsy. Wiley Periodicals, Inc. © 2010 International League Against Epilepsy.

  6. Historical achievements of self-monitoring of blood glucose technology development in Japan.

    Science.gov (United States)

    Yamada, Shigeki

    2011-09-01

    Japanese companies were the first in the world to achieve a colorimetric glucose measurement meter back in 1973. Over the following 40 or so years, they succeeded in achieving a much greater level of user-friendliness and performance and in so doing, have contributed to the spread of self-monitoring of blood glucose. This article aims to unravel the history of blood glucose measurement's technological developments; to look at the direction and features of the development path Japan is taking; as well as to introduce some Japanese products that are on the market. © 2011 Diabetes Technology Society.

  7. Variations in Postprandial Blood Glucose Responses and Satiety after Intake of Three Types of Bread

    OpenAIRE

    Lunde, Marianne S. H.; Hjellset, Victoria T.; Holmboe-Ottesen, Gerd; Høstmark, Arne T.

    2011-01-01

    Background The burden of obesity, type 2 diabetes (T2D) and cardio-vascular diseases (CVD) is rapidly increasing worldwide. Impaired glucose tolerance (IGT), in which the blood glucose level is higher than normal but not as high as in diabetes, is also a major public health problem. People with IGT have a higher risk of developing T2D and CVD, and especially the magnitude and duration of the postprandial blood glucose concentration (PPG) seems of crucial importance. In Norway, immigrants from...

  8. Data Based Prediction of Blood Glucose Concentrations Using Evolutionary Methods.

    Science.gov (United States)

    Hidalgo, J Ignacio; Colmenar, J Manuel; Kronberger, Gabriel; Winkler, Stephan M; Garnica, Oscar; Lanchares, Juan

    2017-08-08

    Predicting glucose values on the basis of insulin and food intakes is a difficult task that people with diabetes need to do daily. This is necessary as it is important to maintain glucose levels at appropriate values to avoid not only short-term, but also long-term complications of the illness. Artificial intelligence in general and machine learning techniques in particular have already lead to promising results in modeling and predicting glucose concentrations. In this work, several machine learning techniques are used for the modeling and prediction of glucose concentrations using as inputs the values measured by a continuous monitoring glucose system as well as also previous and estimated future carbohydrate intakes and insulin injections. In particular, we use the following four techniques: genetic programming, random forests, k-nearest neighbors, and grammatical evolution. We propose two new enhanced modeling algorithms for glucose prediction, namely (i) a variant of grammatical evolution which uses an optimized grammar, and (ii) a variant of tree-based genetic programming which uses a three-compartment model for carbohydrate and insulin dynamics. The predictors were trained and tested using data of ten patients from a public hospital in Spain. We analyze our experimental results using the Clarke error grid metric and see that 90% of the forecasts are correct (i.e., Clarke error categories A and B), but still even the best methods produce 5 to 10% of serious errors (category D) and approximately 0.5% of very serious errors (category E). We also propose an enhanced genetic programming algorithm that incorporates a three-compartment model into symbolic regression models to create smoothed time series of the original carbohydrate and insulin time series.

  9. Energized by love: thinking about romantic relationships increases positive affect and blood glucose levels.

    Science.gov (United States)

    Stanton, Sarah C E; Campbell, Lorne; Loving, Timothy J

    2014-10-01

    We assessed the impact of thinking of a current romantic partner on acute blood glucose responses and positive affect over a short period of time. Participants in romantic relationships were randomly assigned to reflect on their partner, an opposite-sex friend, or their morning routine. Blood glucose levels were assessed prior to reflection, as well as at 10 and 25 min postreflection. Results revealed that individuals in the routine and friend conditions exhibited a decline in glucose over time, whereas individuals in the partner condition did not exhibit this decline (rather, a slight increase) in glucose over time. Reported positive affect following reflection was positively associated with increases in glucose, but only for individuals who reflected on their partner, suggesting this physiological response reflects eustress. These findings add to the literature on eustress in relationships and have implications for relationship processes. Copyright © 2014 Society for Psychophysiological Research.

  10. The relationships between blood pressure, blood glucose, and bone mineral density in postmenopausal Turkish women

    Directory of Open Access Journals (Sweden)

    Cakmak HA

    2015-10-01

    Full Text Available Huseyin Altug Cakmak,1 Burcu Dincgez Cakmak,2 Ayse Ender Yumru,3 Serkan Aslan,4 Asim Enhos,1 Ali Kemal Kalkan,4 Ebru Inci Coskun,5 Abdullah Serdar Acikgoz,6 Suat Karatas3 1Department of Cardiology, Mustafakemalpasa Government Hospital, Bursa, 2Department of Obstetric and Gynecology, Rize Kackar Government Hospital, Rize, 3Department of Obstetric and Gynecology, Sisli Hamidiye Etfal Training and Research Hospital, 4Department of Cardiology, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, 5Department of Obstetric and Gynecology, Inonu University, Malatya, 6Department of Obstetric and Gynecology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey Background: Hypertension, diabetes mellitus, and osteoporosis are important comorbidities commonly seen in postmenopausal women. The aim of the present study was to investigate the relationships between blood pressure, blood glucose, and bone mineral density (BMD in postmenopausal Turkish women.Methods: In this cross-sectional study, 270 consecutive patients who were admitted to an outpatient clinic with vasomotor symptoms and/or at least 1 year of amenorrhea were included. The patients were categorized into three groups according to their blood pressure and metabolic status as follows: normotensive, hypertensive nondiabetics, and hypertensive diabetics. The T- and z-scores of the proximal femur and lumbar vertebrae were measured with the dual-energy X-ray absorptiometry method to assess the BMD of the study groups.Results: Lumbar vertebral T-scores (P<0.001, lumbar vertebral z-scores (P<0.003, and proximal femoral T-scores (P<0.001 were demonstrated to be significantly lower in the hypertensive diabetic group compared to the hypertensive nondiabetic and normotensive groups. Systolic blood pressure was significantly inversely correlated with lumbar vertebral T-scores (r=-0.382; P=0.001, lumbar vertebral z-scores (r=-0.290; P=0.001, and

  11. Chaos based blood glucose noninvasive measurement: new concept and custom study

    Directory of Open Access Journals (Sweden)

    Cui Li

    2017-01-01

    Full Text Available Background. Non invasive monitoring of Blood Glucose (BG has been a challenge calling for new accurate and fast measurement methods. Objective. To propose new concept of chaos based BG non invasive test aiming at personal customization requirements. Methods. First to build the compact RC model of tissue BG through impedance precision measuring Kit, then to simulate and soft-test BG by Boolean chaotic Codec circuits in soft tool Multisim 13.0, The third to capture the chaotic decoding outputs with the Kit plus PC in calculated signatures of resistor and phase of the tested impedance at the subjects’ left wrist in synchronous test by Bayer BG meter. Results. All in controlled trials of Bayer BG meter, the chaotic BG modelling had gained three new compared formulae in merits of errors less than 1mmol/L and latency less than 1minute. Conclusion. During further verification of this chaotic test paradigm, the opened logic route of above methods will boost measurement experts’ confidence in overcoming future problems of blood glucose monitoring in vivo.

  12. Self-monitoring blood glucose--non-insulin-treated type 2 diabetes in Australian general practice.

    Science.gov (United States)

    Henderson, Joan; Valenti, Lisa; Bayram, Clare; Miller, Graeme

    2013-09-01

    Benefits of self-monitoring blood glucose (SMBG) in non-insulin-treated type 2 diabetes (T2D) are questionable. We investigated proportions of general practitioner (GP) patients who self-monitor, and associations between SMBG, glycosylated haemoglobin (HbA1c) and body mass index (BMI). Sub-studies of the Bettering the Evaluation and Care of Health (BEACH) program, involving 5 730 patients from 194 GPs. Outcomes Type 2 diabetes prevalence; HbA1c; BMI; blood glucose (BG) monitoring routine. Prevalence of non-insulin-treated T2D was 6.7%. Mean HbA1c level was 7.1%. Almost half (47.5%) of T2D patients were obese compared with 26.7% of patients at all BEACH encounters in 2011-2012. Of 344 non-insulin-treated T2D patients, 79.4% self-monitored fasting BG and 69.7% of 314 self-monitored post-prandial BG. For both groups, mean HbA1c was significantly higher for those who tested daily than for those who never tested. Patients with non-insulin-treated T2D who test BG daily may be those struggling for control. For others, benefits seem minimal for the proportion utilising self-monitoring.

  13. Introduction of the glucose meter as a tool of self-monitoring of blood glucose for patients from Santos

    Directory of Open Access Journals (Sweden)

    Sílvia Corral de Arêa Leão Souza

    2014-04-01

    Introduction: the introduction of home blood glucose monitoring aimed autonomy for patient self-care, result in reducing the complications of Diabetes mellitus (DM. Objectives: evaluate and analyze the evolution of HbA1c levels in insulin-dependent patients in Santos/SP after the introduction of blood glucose self-monitoring. Methods: through a transversal study with patient forms, it has been selected a sample of 20% of insulin-dependent patients total (160/800 patients according to age range and sex. Those data was analyzed through the SPSS 15.0 software (SPSS Inc. Chicago-IL using ANOVA test with repeated measures, comparing the mean values from before the use of the home self-monitoring with the values of tests performed after its introduction, in order to identify reduction or not of the HbA1c patients' values. This study was approved by ethics committees of UNIFESP and by Secretaria Municipal de Saúde de Santos. Results: of the 157 used records, with a total of 471 HbA1c values, only five (3.2% belonged to the range of 21 - 40 years, the range of 41 - 60 years presented with higher population possessing 47 patients (30% and those over 60 years prevailed in the study with 105 patients listed (66.9%. The HbA1c values presented a statically significant reduction after 6 months from starting use the glucose meter with P < 0.05 (0.014, demonstrating that after six months of glucose meter use, it was noticed the statistic reduction in HbA1c levels. Conclusions: the home self-monitoring of blood glucose, coupled with drug intervention, reduces HbA1c levels in a six-month interval.

  14. Paper membrane-based SERS platform for the determination of glucose in blood samples.

    Science.gov (United States)

    Torul, Hilal; Çiftçi, Hakan; Çetin, Demet; Suludere, Zekiye; Boyacı, Ismail Hakkı; Tamer, Uğur

    2015-11-01

    In this report, we present a paper membrane-based surface-enhanced Raman scattering (SERS) platform for the determination of blood glucose level using a nitrocellulose membrane as substrate paper, and the microfluidic channel was simply constructed by wax-printing method. The rod-shaped gold nanorod particles were modified with 4-mercaptophenylboronic acid (4-MBA) and 1-decanethiol (1-DT) molecules and used as embedded SERS probe for paper-based microfluidics. The SERS measurement area was simply constructed by dropping gold nanoparticles on nitrocellulose membrane, and the blood sample was dropped on the membrane hydrophilic channel. While the blood cells and proteins were held on nitrocellulose membrane, glucose molecules were moved through the channel toward the SERS measurement area. Scanning electron microscopy (SEM) was used to confirm the effective separation of blood matrix, and total analysis is completed in 5 min. In SERS measurements, the intensity of the band at 1070 cm(-1) which is attributed to B-OH vibration decreased depending on the rise in glucose concentration in the blood sample. The glucose concentration was found to be 5.43 ± 0.51 mM in the reference blood sample by using a calibration equation, and the certified value for glucose was 6.17 ± 0.11 mM. The recovery of the glucose in the reference blood sample was about 88 %. According to these results, the developed paper-based microfluidic SERS platform has been found to be suitable for use for the detection of glucose in blood samples without any pretreatment procedure. We believe that paper-based microfluidic systems may provide a wide field of usage for paper-based applications.

  15. Strict versus liberal target range for perioperative glucose in patients undergoing coronary artery bypass grafting: a prospective randomized controlled trial.

    Science.gov (United States)

    Desai, Shalin P; Henry, Linda L; Holmes, Sari D; Hunt, Sharon L; Martin, Chidima T; Hebsur, Shrinivas; Ad, Niv

    2012-02-01

    The purpose of this study was to test the hypothesis that a liberal blood glucose strategy (121-180 mg/dL) is not inferior to a strict blood glucose strategy (90-120 mg/dL) for outcomes in patients after first-time isolated coronary artery bypass grafting and is superior for glucose control and target blood glucose management. A total of 189 patients undergoing coronary artery bypass grafting were investigated in this prospective randomized study to compare 2 glucose control strategies on patient perioperative outcomes. Three methods of analyses (intention to treat, completer, and per protocol) were conducted. Observed power was robust (>80%) for significant results. The groups were similar on preoperative hemoglobin A(1c) and number of diabetic patients. The liberal group was found to be noninferior to the strict group for perioperative complications and superior on glucose control and target range management. The liberal group had significantly fewer patients with hypoglycemic events (liberal range after coronary artery bypass grafting led to similar outcomes compared with a strict target range and was superior in glucose control and target range management. On the basis of the results of this study, a target blood glucose range of 121 to 180 mg/dL is recommended for patients after coronary artery bypass grafting as advocated by the Society of Thoracic Surgeons. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. ( Myrciaria jaboticaba ) peel on blood glucose and cholesterol levels ...

    African Journals Online (AJOL)

    Berg) peel was lyophilized and the proximate composition, total anthocyanins and polyphenolic content were determined. The effect of the freeze-dried jaboticaba peels (FJP) in the plasmatic levels of glucose, lipid fractions, aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in Wistar adult male rats was ...

  17. Examination of liver and muscle glycogen and blood glucose levels ...

    African Journals Online (AJOL)

    Administrator

    2011-09-05

    Sep 5, 2011 ... consist 1% of the total body weight. This source is sufficient to provide the energy need for a .... Atlantic salmon consists 0.5 to 9.5% of the liver weight. Ali and Jauncey (2005) stated that liver glycogen ..... Plasma glucose and liver glycogen of. African catfish (Clarias gariepinus) exposed to petrol. J. Fish. Int.

  18. Daidzin decreases blood glucose and lipid in streptozotocin ...

    African Journals Online (AJOL)

    Serum or hepatic levels of lipid, proinflammatory factors, malondialdehyde (MDA) .... Animals were housed under a constant 12-h light and dark cycle and in an environment of 21 - 23 °C. To test the effect of DZ in normal mice, the animals were randomly divided into ..... hepatic glucose and lipid metabolism in diabetic db/db.

  19. The Effects of Capparis Spinosa Hydroalcoholic Extract on Blood Glucose and Lipids Serum in Diabetic and Normal Male Rats

    Directory of Open Access Journals (Sweden)

    M Negahdarizadeh

    2011-06-01

    Full Text Available Introduction & Objective: Diabetes mellitus is one of the most common endocrine disorders in the world which affects glucose metabolism in the body. Diabetes mellitus is due to lack of insulin secretion and/or failure in insulin action. Researches conducted in the last few decades on plants have reported anti-diabetic properties for some herbs and their traditional use for diabetes treatment. Capparis spinosa is one of these herbs which are used as an anti-diabetic treatment in tribal medicine. The objective of the present study was to examine the anti-diabetic effects of Capparis spinosa on blood glucose and serum lipids in streptozotocin induced diabetes in male rats. Materials & Methods: In this experimental study conducted at Yasouj University of Medical Sciences in 2010, five groups of animals were selected. Three groups out of five were administered with intraperitoneal injection of streptozotocin to become diabetic. Group I were fed normal diet. Group II of animals received 20 mg/kg/day Capparis spinosa extract. Group III received no treatment (diabetic control and animals of groups IV and V were treated with capparis spinosa fruit extract 20 and 30 mg/kg body weight respectively for three weeks. Blood glucose, triglycerides, total cholesterol, LDL, HDL and body weight were measured in all animals. The collected data was analyzed by the SPSS software using one-way ANOVA. Results: Treatment with the 30 mg/kg/body weight of capparis spinosa fruit extract showed a significant decrease in blood glucose, triglycerides, total cholesterol and LDL, and a significant increase in HDL level. In addition, administration of 20 mg/kg/body weight of capparis spinosa extract decreased blood glucose and lipid levels in diabetic rats. Conclusion: It can be concluded that the oral administration of capparis spinosa extract at the dose of 30 mg/kg/body weight has glucose and lipids lowering activity in diabetic rats.

  20. Peripheral and central venous blood glucose concentrations in dogs and cats with acute arterial thromboembolism.

    Science.gov (United States)

    Klainbart, S; Kelmer, E; Vidmayer, B; Bdolah-Abram, T; Segev, G; Aroch, I

    2014-01-01

    Acute limb paralysis because of arterial thromboembolism (ATE) occurs in cats and less commonly in dogs. ATE is diagnosed based on physical examination findings and, occasionally, advanced imaging. Peripheral, affected limb venous glucose concentration is decreased in ATE, whereas its systemic concentration is within or above reference interval. Client-owned cats and dogs were divided into 3 respective groups: acute limb paralysis because of ATE (22 cats and 9 dogs); acute limb paralysis secondary to orthopedic or neurologic conditions (nonambulatory controls; 10 cats and 11 dogs); ambulatory animals presented because of various diseases (ambulatory controls; 10 cats and 9 dogs). Prospective observational, clinical study. Systemic and local (affected limb) blood glucose concentrations were measured. Their absolute and relative differences (ΔGlu and %ΔGlu, respectively) were compared among groups. ΔGlu and %ΔGlu were significantly higher in the ATE cats and dogs groups, compared to both of their respective controls (P cats, respectively, and 1.00 and 1.00, in dogs, respectively. ΔGlu cutoffs of 30 mg/dL and 16 mg/dL, in cats and dogs, respectively, corresponded to sensitivity and specificity of 100% and 90% in cats, respectively, and 100% in dogs. ΔGlu and %ΔGlu are accurate, readily available, diagnostic markers of acute ATE in paralyzed cats and dogs. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  1. On the suitability of refractometry for the analysis of glucose in blood-derived fluids.

    Science.gov (United States)

    Zirk, K; Poetzschke, H

    2004-07-01

    Refractometry is the determination of the optical refractive index of a substance or a mixture of substances. It is a very sensitive method for the detection and quantification of dissolved analytes, but it is incapable of distinguishing between different analytes. The aim of this investigation was to determine the principle suitability of refractometry for the quantification of glucose (blood sugar) in blood and various blood fluids which can readily be obtained for medical diagnosis, in particular blood plasma, blood serum, and their ultrafiltrates. After the oral intake of freshly dissolved alpha-glucose, the in vivo blood contents of the alpha and beta anomers of glucose were found to be in an at least approximate equilibrium at all times. This observation is a prerequisite for a refractometrical determination of glucose due to the fact that both molecule forms have different refractive index increments. An assessment of the glucose content in untreated blood fluids was not possible, since no suitable relationship to the refractive index was found, most probably due to the influence of the many other substances present in blood on this parameter. However, after removal of certain macromolecules by ultrafiltration, value pairs showed a high level of correlation, providing the nominal molecular weight limit (cut-off) of the ultrafilter used possessed a maximum of 300 kDa. Besides macromolecules, the osmolality of the fluids undergoing measurement also proved to be a considerable interfering factor, particularly when values were outside the normal physiological range between 285 and 293 mmol/L. If a clinical application of this method is to be contemplated it is imperative (1) that blood cells are separated and removed, (2) that macromolecules present in plasma or serum are removed, e.g. by ultrafiltration, and (3) that beyond the results presented the influence of all small molecules other than glucose on the overall refractive index be determined and included in

  2. Self-Monitoring of Blood Glucose : Professional Advice and Daily Practice of Patients With Diabetes

    NARCIS (Netherlands)

    Hortensius, Johanna; van der Bijl, Jaap J.; Kleefstra, Nanne; Houweling, Sebastiaan T.; Bilo, Henk J. G.

    2012-01-01

    Purpose This study investigated the advice given by diabetes educators in Europe, and the daily practice of Dutch patients with diabetes regarding the use of the first or second drop of blood and other aspects concerning self-monitoring of blood glucose (SMBG). Method During a diabetes conference in

  3. A tripeptide Diapin effectively lowers blood glucose levels in male type 2 diabetes mice by increasing blood levels of insulin and GLP-1.

    Directory of Open Access Journals (Sweden)

    Jifeng Zhang

    Full Text Available The prevalence of type 2 diabetes (T2D is rapidly increasing worldwide. Effective therapies, such as insulin and Glucagon-like peptide-1 (GLP-1, require injections, which are costly and result in less patient compliance. Here, we report the identification of a tripeptide with significant potential to treat T2D. The peptide, referred to as Diapin, is comprised of three natural L-amino acids, GlyGlyLeu. Glucose tolerance tests showed that oral administration of Diapin effectively lowered blood glucose after oral glucose loading in both normal C57BL/6J mice and T2D mouse models, including KKay, db/db, ob/ob mice, and high fat diet-induced obesity/T2D mice. In addition, Diapin treatment significantly reduced casual blood glucose in KKay diabetic mice in a time-dependent manner without causing hypoglycemia. Furthermore, we found that plasma GLP-1 and insulin levels in diabetic models were significantly increased with Diapin treatment compared to that in the controls. In summary, our findings establish that a peptide with minimum of three amino acids can improve glucose homeostasis and Diapin shows promise as a novel pharmaceutical agent to treat patients with T2D through its dual effects on GLP-1 and insulin secretion.

  4. Social Inclusion Predicts Lower Blood Glucose and Low-Density Lipoproteins in Healthy Adults.

    Science.gov (United States)

    Floyd, Kory; Veksler, Alice E; McEwan, Bree; Hesse, Colin; Boren, Justin P; Dinsmore, Dana R; Pavlich, Corey A

    2017-08-01

    Loneliness has been shown to have direct effects on one's personal well-being. Specifically, a greater feeling of loneliness is associated with negative mental health outcomes, negative health behaviors, and an increased likelihood of premature mortality. Using the neuroendocrine hypothesis, we expected social inclusion to predict decreases in both blood glucose levels and low-density lipoproteins (LDLs) and increases in high-density lipoproteins (HDLs). Fifty-two healthy adults provided self-report data for social inclusion and blood samples for hematological tests. Results indicated that higher social inclusion predicted lower levels of blood glucose and LDL, but had no effect on HDL. Implications for theory and practice are discussed.

  5. Perfil das mães de neonatos com controle glicêmico nas primeiras horas de vida Perfil de las madres de neonatos con control glucémico en las primeras horas de vida Profile of mothers of newborns with blood glucose control in the first hours of life

    Directory of Open Access Journals (Sweden)

    Patrícia de Freitas

    2010-09-01

    glucosado al 5% durante el trabajo de parto y el parto en sí. Deben ser efectuados estudios correlacionales, analizando variables maternas y ocurrencia de hipoglucemia neonatal, con el objetivo de identificar los factores predictores de esta patología neonatal.Some maternal factors associated with neonatal hypoglycemia justify monitoring blood glucose levels in the first 24 hours of life. The objective of this study was to describe the socio-demographic and obstetric characteristics of mothers to newborns undergoing capillary blood glucose control in the first 24 hours of life, hospitalized in a rooming-in maternity ward of a Baby Friendly Hospital. This is a descriptive exploratory study which involved the analysis of data from 380 medical records of mothers hospitalized from July to December, 2006 at the maternity ward of the University of São Paulo Teaching Hospital. It was found that 18 (5.6% mothers developed gestational diabetes, none of them were treated with oral hypoglycemic agents, 53 (16.2% had hypertension during pregnancy and 17 (32.1% used anti-hypertensive medication, 215 (56.6% received glucose 5% continuous infusion during labor and delivery. Correlation studies linking maternal variables and neonatal hypoglycemia are needed to identify the predicting factors of this neonatal morbidity.

  6. Age-adjusted glycated albumin accurately reflects blood glucose in patients with neonatal diabetes mellitus: comparison with calculated glycated albumin determined by past blood glucose concentrations.

    Science.gov (United States)

    Suzuki, Shigeru; Furuya, Akiko; Oshima, Miho; Amamiya, Satoshi; Nakao, Atsushi; Wada, Keiko; Okuhara, Koji; Hayano, Satoshi; Imamoto, Aya; Matsuo, Kumihiro; Tanahashi, Yusuke; Azuma, Hiroshi; Koga, Masafumi

    2016-01-01

    Glycated albumin is a useful glycaemic control indicator for neonatal diabetes mellitus. However, glycated albumin concentrations in infants are lower than those in adults and increase in an age-dependent manner. Based on our investigation of non-diabetic subjects, we proposed the possibility that the reference range for adults may be used regardless of age, provided that age-adjusted glycated albumin is employed. In the present study, we evaluate the usefulness of age-adjusted glycated albumin in neonatal diabetes mellitus patients. Six neonatal diabetes mellitus patients (four patients with permanent neonatal diabetes mellitus and two patients with transient neonatal diabetes mellitus) were included. Measured glycated albumin or age-adjusted glycated albumin was compared to calculated glycated albumin, which was determined using calculation formulae we had reported based on past blood glucose over the 50 days before measurement of glycated albumin. Measured glycated albumin was significantly lower than calculated glycated albumin (20.5 ± 4.9% versus 28.2 ± 6.1%; p diabetes mellitus in remission were lower than the reference range for adults, whereas age-adjusted glycated albumin concentrations were within the reference range for adults. We demonstrated that age-adjusted glycated albumin concentrations were consistent with calculated glycated albumin. Age-adjusted glycated albumin is therefore a useful glycaemic control indicator for neonatal diabetes mellitus patients. © The Author(s) 2015.

  7. Effects of Consuming Preloads with Different Energy Density and Taste Quality on Energy Intake and Postprandial Blood Glucose

    Directory of Open Access Journals (Sweden)

    Siew Ling Tey

    2018-01-01

    Full Text Available Consumption of reduced energy dense foods and drink has the potential to reduce energy intake and postprandial blood glucose concentrations. In addition, the taste quality of a meal (e.g., sweet or savoury may play a role in satiation and food intake. The objective of this randomised crossover study was to examine whether energy density and taste quality has an impact on energy intake and postprandial blood glucose response. Using a preload design, participants were asked to consume a sweet (“Cheng Teng” or a savoury (broth preload soup in high energy density (HED; around 0.50 kcal/g; 250 kcal or low energy density (LED; around 0.12 kcal/g; 50 kcal in mid-morning and an ad libitum lunch was provided an hour after the preload. Participants recorded their food intake for the rest of the day after they left the study site. Energy compensation and postprandial blood glucose response were measured in 32 healthy lean males (mean age = 28.9 years, mean BMI = 22.1 kg/m2. There was a significant difference in ad libitum lunch intake between treatments (p = 0.012, with higher intake in sweet LED and savoury LED compared to sweet HED and savoury HED. Energy intake at subsequent meals and total daily energy intake did not differ between the four treatments (both p ≥ 0.214. Consumption of HED preloads resulted in a larger spike in postprandial blood glucose response compared with LED preloads, irrespective of taste quality (p < 0.001. Energy density rather than taste quality plays an important role in energy compensation and postprandial blood glucose response. This suggests that regular consumption of low energy-dense foods has the potential to reduce overall energy intake and to improve glycemic control.

  8. [Metabolic control in the critically ill patient an update: hyperglycemia, glucose variability hypoglycemia and relative hypoglycemia].

    Science.gov (United States)

    Pérez-Calatayud, Ángel Augusto; Guillén-Vidaña, Ariadna; Fraire-Félix, Irving Santiago; Anica-Malagón, Eduardo Daniel; Briones Garduño, Jesús Carlos; Carrillo-Esper, Raúl

    Metabolic changes of glucose in critically ill patients increase morbidity and mortality. The appropriate level of blood glucose has not been established so far and should be adjusted for different populations. However concepts such as glucose variability and relative hypoglycemia of critically ill patients are concepts that are changing management methods and achieving closer monitoring. The purpose of this review is to present new data about the management and metabolic control of patients in critical areas. Currently glucose can no longer be regarded as an innocent element in critical patients; both hyperglycemia and hypoglycemia increase morbidity and mortality of patients. Protocols and better instruments for continuous measurement are necessary to achieve the metabolic control of our patients. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  9. Cerebral blood flow and glucose metabolism measured with positron emission tomography are decreased in human type 1 diabetes.

    Science.gov (United States)

    van Golen, Larissa W; Huisman, Marc C; Ijzerman, Richard G; Hoetjes, Nikie J; Schwarte, Lothar A; Lammertsma, Adriaan A; Diamant, Michaela

    2013-08-01

    Subclinical systemic microvascular dysfunction exists in asymptomatic patients with type 1 diabetes. We hypothesized that microangiopathy, resulting from long-standing systemic hyperglycemia and hyperinsulinemia, may be generalized to the brain, resulting in changes in cerebral blood flow (CBF) and metabolism in these patients. We performed dynamic [(15)O]H2O and [(18)F]-fluoro-2-deoxy-d-glucose brain positron emission tomography scans to measure CBF and cerebral glucose metabolism (CMRglu), respectively, in 30 type 1 diabetic patients and 12 age-matched healthy controls after an overnight fast. Regions of interest were automatically delineated on coregistered magnetic resonance images and full kinetic analysis was performed. Plasma glucose and insulin levels were higher in patients versus controls. Total gray matter CBF was 9%, whereas CMRglu was 21% lower in type 1 diabetic subjects versus control subjects. We conclude that at real-life fasting glucose and insulin levels, type 1 diabetes is associated with decreased resting cerebral glucose metabolism, which is only partially explained by the decreased CBF. These findings suggest that mechanisms other than generalized microangiopathy account for the altered CMRglu observed in well-controlled type 1 diabetes.

  10. The Coupling of Cerebral Metabolic Rate of Glucose and Cerebral Blood Flow In Vivo

    DEFF Research Database (Denmark)

    Hasselbalch, Steen; Paulson, Olaf Bjarne

    2012-01-01

    The energy supplied to the brain by metabolic substrate is largely utilized for maintaining synaptic transmission. In this regulation cerebral blood flow and glucose consumption is tightly coupled as well in the resting condition as during activation. Quantification of cerebral blood flow...... and metabolism was originally performed using the Kety-Schmidt method and this method still represent the gold standard by which subsequent methods have been evaluated. However, in its classical setting, the method overestimates cerebral blood flow. Studies of metabolic changes during activation must take...... difficulties due to limitation in resolution and partial volume effects. In contrast to the tight coupling between regional glucose metabolism and cerebral blood flow, there is an uncoupling between flow and oxygen consumption as the latter only increases to a limited extend. The excess glucose uptake is thus...

  11. Association of physical activity with blood pressure and blood glucose among Malaysian adults: a population-based study.

    Science.gov (United States)

    Teh, Chien Huey; Chan, Ying Ying; Lim, Kuang Hock; Kee, Chee Cheong; Lim, Kuang Kuay; Yeo, Pei Sien; Azahadi, Omar; Fadhli, Yusoff; Tahir, Aris; Lee, Han Lim; Nazni, Wasi Ahmad

    2015-12-03

    The health-enhancing benefits of physical activity (PA) on hypertension and diabetes have been well documented for decades. This study aimed to determine the association of PA with systolic and diastolic blood pressure as well as blood glucose in the Malaysian adult population. Data were extracted from the 2011 National Health and Morbidity Survey (NHMS), a nationally representative, cross-sectional study. A two-stage stratified sampling method was used to select a representative sample of 18,231 Malaysian adults aged 18 years and above. The PA levels of the respondents were categorised as low, moderate or high according to the International Physical Activity Questionnaire (IPAQ)-short form. Blood pressure and fasting blood glucose levels were measured using a digital blood pressure-measuring device and finger-prick test, respectively. Systolic blood pressure (SBP) level was positively associated with PA level (p = 0.02) whilst no significant association was noted between PA level and diastolic blood pressure (DBP). In contrast, respondents with low (adjusted coefficient = 0.17) or moderate (adjusted coefficient = 0.03) level of PA had significantly higher blood glucose level as compared to those who were highly active (p = 0.04). A significant negative association was observed between PA level and blood glucose only. Future studies should employ an objective measurement in estimating PA level in order to elucidate the actual relationship between PA, hypertension and diabetes for the development of effective interventions to combat the increasing burden of premature-mortality and cardiovascular disease-related morbidity in Malaysia.

  12. Dapagliflozin-lowered blood glucose reduces respiratory Pseudomonas aeruginosa infection in diabetic mice.

    Science.gov (United States)

    Åstrand, Annika; Wingren, Cecilia; Benjamin, Audra; Tregoning, John S; Garnett, James P; Groves, Helen; Gill, Simren; Orogo-Wenn, Maria; Lundqvist, Anders J; Walters, Dafydd; Smith, David M; Taylor, John D; Baker, Emma H; Baines, Deborah L

    2017-05-01

    Hyperglycaemia increases glucose concentrations in airway surface liquid and increases the risk of pulmonary Pseudomonas aeruginosa infection. We determined whether reduction of blood and airway glucose concentrations by the anti-diabetic drug dapagliflozin could reduce P. aeruginosa growth/survival in the lungs of diabetic mice. The effect of dapagliflozin on blood and airway glucose concentration, the inflammatory response and infection were investigated in C57BL/6J (wild type, WT) or leptin receptor-deficient (db/db) mice, treated orally with dapagliflozin prior to intranasal dosing with LPS or inoculation with P. aeruginosa. Pulmonary glucose transport and fluid absorption were investigated in Wistar rats using the perfused fluid-filled lung technique. Fasting blood, airway glucose and lactate concentrations were elevated in the db/db mouse lung. LPS challenge increased inflammatory cells in bronchoalveolar lavage fluid from WT and db/db mice with and without dapagliflozin treatment. P. aeruginosa colony-forming units (CFU) were increased in db/db lungs. Pretreatment with dapagliflozin reduced blood and bronchoalveolar lavage glucose concentrations and P. aeruginosa CFU in db/db mice towards those seen in WT. Dapagliflozin had no adverse effects on the inflammatory response in the mouse or pulmonary glucose transport or fluid absorption in the rat lung. Pharmacological lowering of blood glucose with dapagliflozin effectively reduced P. aeruginosa infection in the lungs of diabetic mice and had no adverse pulmonary effects in the rat. Dapagliflozin has potential to reduce the use, or augment the effect, of antimicrobials in the prevention or treatment of pulmonary infection. © 2017 The Authors. British Journal of Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.

  13. Evaluation of blood glucose and thyroid function in Sudanese diabetic patients

    International Nuclear Information System (INIS)

    Agarib, M.O.A.

    2008-03-01

    This study composes of two parts. The first one is a survey of thyroid abnormalities, and the second one is experiment to estimate the level of thyroid hormones (T 4 , T 3 , TSH) among diabetic population and the relationship between the level of glucose, thyroid hormones and lipid profile (TC, LDL, TG, HDL) and comparison of the results with non diabetic group. The survey part of the study to determine the thyroid abnormalities, hypothyroidism or hyperthyroidism clinical or subclinical. Also the study group was divided in to two groups according to insulin requirement. Type I is insulin-dependent diabetes mellitus and type II is non insulin-dependent diabetes mellitus. The study subjects selected for this study consist of one hundred Sudanese diabetic patients, they had mean age of 46.51±10.672 years, a mean height of 162.06±10.77 cm and a mean weight of 73.47±14.91 kg. Fifty healthy non-diabetic people without endocrine disease were chosen as controls. Glucose, and thyroid hormones, thyroxine and triiodothyronine (total T 4 and T 3 ) and thyroid stimulating hormone (TSH) were measured. In addition hemoglobin (Hb), total cholesterol (TC), triglyceride (TG), high-density lipoproteins (HDL) were also measured in both groups. Low-density lipoprotein (LDL) was calculated for each sample. Physical examinations such as height, weight, and history of diabetes, family history, treatment were recorded in both groups. Determination of serum hormones concentration was carried out using highly sensitive RIA technique. While determination of blood glucose, hemoglobin, and lipid profile was carried out using enzymatic colorimetric method. The results of this study showed that: 13 patients of the population screened had thyroid disease. The commonest diagnosis was sub clinical hyperthyroidism (6%), followed by sub clinical hypothyroidism (5%) and hyperthyroidism (2%). Female patients with diabetes had the highest annual risk of developing thyroid disease but all patient

  14. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  15. Blood glucose monitoring in type 2 diabetes – Nepalese patients’ opinions and experiences

    Science.gov (United States)

    Sapkota, Sujata; Brien, Jo-anne E; Aslani, Parisa

    2017-01-01

    ABSTRACT Background: Blood glucose monitoring forms a vital component of diabetes care. Monitoring conducted at home using glucometers, and in laboratories by professionals, are two common methods of blood glucose monitoring in clinical practice. Objective: To investigate Nepalese patients’ perceptions and practices of blood glucose monitoring in diabetes. Methods: In-depth interviews were conducted with 48 Nepalese participants with type 2 diabetes in Sydney and Kathmandu. The interviews were audio-recorded, transcribed verbatim and thematically analysed. Results: In Australia, most participants perceived home monitoring as useful; and both home and laboratory monitoring were conducted at fairly regular intervals. In Nepal, only a small number conducted home monitoring and the laboratory method formed the primary method of day-to-day monitoring. The laboratory method was preferred due to easy access to laboratories, lack of faith in glucometers and perceptions that home monitoring is costlier. However, overall monitoring was irregular in Nepal. In addition to the healthcare system which enabled cheaper self-monitoring in Australia, Nepalese in Australia also tended to have a better understanding about the purpose of home monitoring. Conclusions: This study has highlighted the disparity in perceptions and practices related to blood glucose monitoring. Understanding the importance of blood glucose monitoring and access to affordable resources are critical facilitators for conducting regular monitoring. Both patient and health-system factors play a key role in ensuring continued diabetes monitoring and management. PMID:28585892

  16. Accuracy and precision of the Prodigy AutoCode blood glucose monitor.

    Science.gov (United States)

    Prohaska, Emily S; Herring, Charles; Russell, Gregory B; Smith, Jennifer D

    2012-04-01

    To assess the accuracy and precision of the Prodigy AutoCode blood glucose monitor. This open-label, prospective equivalence study was conducted at Wilson Community Health Center in Wilson, North Carolina. Accuracy was assessed by comparing finger stick blood glucose values to venipuncture. Precision was assessed by comparing consecutive finger stick blood glucose values from 2 Prodigy AutoCode monitors. Data were analyzed using paired t tests, signed rank tests, regression, and mixed effect models. Fifty-three subjects completed the study. Meter 1 produced 14 (26%) and meter 2 produced 13 (25%) blood glucose readings outside the acceptable error margin of ±20% set by the International Organization for Standardization (ISO) and the Food and Drug Administration (FDA). Neither meter was accurate compared to venipuncture (P Prodigy AutoCode demonstrated precision between two different monitors but was inaccurate compared to venipuncture. Less than the required 95% of blood glucose values from each monitor fell within the acceptable 20% error margin relative to venipuncture. All readings outside the acceptable error margin were overestimations, indicating potentially significant safety concerns including untreated or undertreated hypoglycemia.

  17. Conversion of oral glucose to lactate in dogs. Primary site and relative contribution to blood lactate

    International Nuclear Information System (INIS)

    Youn, J.H.; Bergman, R.N.

    1991-01-01

    The authors evaluated the relative contribution of oral glucose to arterial lactate and the relative role of the splanchnic bed in converting glucose to lactate in dogs. After an oral glucose load (1.2 g/kg) spiked with [U-14C]glucose (16.9 muCi/kg; protocol 1, n = 7), arterial blood lactate increased from 0.43 ± 0.03 mM at basal to a peak of 1.04 ± 0.07 mM at 45 min and then slowly decreased to 0.47 ± 0.07 mM at 240 min. Arterial blood 14 Clactate peaked at 60 min and then decreased to ∼ 35% of the peak at 4 h. When arterial blood lactate peaked at 45 min, the proportion of arterial lactate that was derived from oral glucose was 34 ± 3%. The integrated area under the curve of lactate derived from exogenous glucose was 40 ± 2% of that of total lactate. The splanchnic bed released lactate and 14 Clactate during the initial 2 h after oral 14 Cglucose. Thus, the splanchnic bed apparently contributed to the conversion of exogenous glucose to lactate. In the matched experiments (protocol 2, n = 5), dogs were given the same amount of oral glucose but no 14 Cglucose, and [U-14C]lactate was infused into the right atrium to match the splanchnic 14 Clactate release from the first experiment. Despite a well-matched splanchnic 14 Clactate contribution, arterial concentrations of 14 Clactate were markedly lower in protocol 2 compared with protocol 1. The integrated area under the 14 Clactate profile in protocol 2 was only 11 ± 1% of that in protocol 1. These results indicate that the splanchnic bed is responsible for only 11% of arterial blood lactate that was derived from oral glucose. They concluded that (1) after oral glucose loading, a major portion of circulating lactate has its origin not in exogenous glucose but in endogenous sources, and (2) the splanchnic bed is not the major site of oral glucose conversion to lactate after glucose ingestion

  18. Use of a Connected Glucose Meter and Certified Diabetes Educator Coaching to Decrease the Likelihood of Abnormal Blood Glucose Excursions: The Livongo for Diabetes Program.

    Science.gov (United States)

    Downing, Janelle; Bollyky, Jenna; Schneider, Jennifer

    2017-07-11

    The Livongo for Diabetes Program offers members (1) a cellular technology-enabled, two-way messaging device that measures blood glucose (BG), centrally stores the glucose data, and delivers messages back to the individual in real time; (2) unlimited BG test strips; and (3) access to a diabetes coaching team for questions, goal setting, and automated support for abnormal glucose excursions. The program is sponsored by at-risk self-insured employers, health plans and provider organizations where it is free to members with diabetes or it is available directly to the person with diabetes where they cover the cost. The objective of our study was to evaluate BG data from 4544 individuals with diabetes who were enrolled in the Livongo program from October 2014 through December 2015. Members used the Livongo glucose meter to measure their BG levels an average of 1.8 times per day. We estimated the probability of having a day with a BG reading outside of the normal range (70-180 mg/dL, or 3.9-10.0 mmol/L) in months 2 to 12 compared with month 1 of the program, using individual fixed effects to control for individual characteristics. Livongo members experienced an average 18.4% decrease in the likelihood of having a day with hypoglycemia (BG 180 mg/dL) in months 2-12 compared with month 1 as the baseline. The biggest impact was seen on hyperglycemia for nonusers of insulin. We do not know all of the contributing factors such as medication or other treatment changes during the study period. These findings suggest that access to a connected glucose meter and certified diabetes educator coaching is associated with a decrease in the likelihood of abnormal glucose excursions, which can lead to diabetes-related health care savings. ©Janelle Downing, Jenna Bollyky, Jennifer Schneider. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 11.07.2017.

  19. Association of physical activity with blood pressure and blood glucose among Malaysian adults: a population-based study

    OpenAIRE

    Teh, Chien Huey; Chan, Ying Ying; Lim, Kuang Hock; Kee, Chee Cheong; Lim, Kuang Kuay; Yeo, Pei Sien; Azahadi, Omar; Fadhli, Yusoff; Tahir, Aris; Lee, Han Lim; Nazni, Wasi Ahmad

    2015-01-01

    Background The health-enhancing benefits of physical activity (PA) on hypertension and diabetes have been well documented for decades. This study aimed to determine the association of PA with systolic and diastolic blood pressure as well as blood glucose in the Malaysian adult population. Methods Data were extracted from the 2011 National Health and Morbidity Survey (NHMS), a nationally representative, cross-sectional study. A two-stage stratified sampling method was used to select a represen...

  20. Non-invasive estimate of blood glucose and blood pressure from a photoplethysmograph by means of machine learning techniques.

    Science.gov (United States)

    Monte-Moreno, Enric

    2011-10-01

    This work presents a system for a simultaneous non-invasive estimate of the blood glucose level (BGL) and the systolic (SBP) and diastolic (DBP) blood pressure, using a photoplethysmograph (PPG) and machine learning techniques. The method is independent of the person whose values are being measured and does not need calibration over time or subjects. The architecture of the system consists of a photoplethysmograph sensor, an activity detection module, a signal processing module that extracts features from the PPG waveform, and a machine learning algorithm that estimates the SBP, DBP and BGL values. The idea that underlies the system is that there is functional relationship between the shape of the PPG waveform and the blood pressure and glucose levels. As described in this paper we tested this method on 410 individuals without performing any personalized calibration. The results were computed after cross validation. The machine learning techniques tested were: ridge linear regression, a multilayer perceptron neural network, support vector machines and random forests. The best results were obtained with the random forest technique. In the case of blood pressure, the resulting coefficients of determination for reference vs. prediction were R(SBP)(2)=0.91, R(DBP)(2)=0.89, and R(BGL)(2)=0.90. For the glucose estimation, distribution of the points on a Clarke error grid placed 87.7% of points in zone A, 10.3% in zone B, and 1.9% in zone D. Blood pressure values complied with the grade B protocol of the British Hypertension society. An effective system for estimate of blood glucose and blood pressure from a photoplethysmograph is presented. The main advantage of the system is that for clinical use it complies with the grade B protocol of the British Hypertension society for the blood pressure and only in 1.9% of the cases did not detect hypoglycemia or hyperglycemia. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. GLP-1 analog raises glucose transport capacity of blood-brain barrier in Alzheimer's disease

    DEFF Research Database (Denmark)

    Gejl, M.; Brock, B.; Egefjord, L.

    2017-01-01

    Objectives: Glucose enters the brain tissue from plasma by facilitated diffusion across the two membranes of the endothelium of the blood-brain barrier (BBB), mediated by the glucose transporter 1 (GLUT1). There is evidence in Alzheimer's disease (AD) of reduction of glucose transport across...... the blood-brain barrier, due to diminished GLUT1 translocation and expression at the BBB. Reduced BBB GLUT1 expression is known to aggravate AD pathology and further impair cognitive function, implying that GLUT1 may be a potential target of therapy directed towards AD neurovascular dysfunction...... and degeneration. Hypothesis: The incretin hormone GLP-1 prevents the decline of the cerebral metabolic rate of glucose that signifies cognitive impairment, synaptic dysfunction, and disease evolution in AD, and GLP-1 may directly activate GLUT1 transport in brain capillary endothelium. For this reason, we here...

  2. High activity enables life on a high-sugar diet : blood glucose regulation in nectar-feeding bats

    NARCIS (Netherlands)

    Kelm, Detlev H; Simon, Ralph; Kuhlow, Doreen; Voigt, Christian C; Ristow, Michael

    2011-01-01

    High blood glucose levels caused by excessive sugar consumption are detrimental to mammalian health and life expectancy. Despite consuming vast quantities of sugar-rich floral nectar, nectar-feeding bats are long-lived, provoking the question of how they regulate blood glucose. We investigated blood

  3. Monitoring blood glucose levels in female mink during the reproductive cycle: 2. Effects of short-term fish oil, chromium picolinate, and acetylsalicylic acid supplementation during late lactation

    Science.gov (United States)

    Hynes, Amber M.J.; Rouvinen-Watt, Kirsti

    2007-01-01

    Mink nursing sickness is a metabolic disorder characterized by hyperglycemia that is similar to the metabolic syndrome associated with type 2, or non-insulin-dependent, diabetes mellitus. This research studied the effects of short-term administration of antidiabetic supplements on the blood glucose concentration in female mink during late lactation. Female mink that had blood glucose levels acetylsalicylic acid (ASA, 100 mg) for 1 wk starting at day 21 post partum. In the NG mink, most of the treatments did not significantly change the blood glucose concentration from day 28 to 42 post partum. However, treatment with ASA alone and treatment with the combination HerO-CrPic-ASA elevated the blood glucose levels when compared with those of the control group, which had received just the basal diet. In the HG mink, all treatment combinations except CrPic alone and ASA alone, reduced the blood glucose concentration. Thus, in lactating mink with hyperglycemia, the blood glucose concentration may be effectively lowered by dietary antidiabetic supplementation; however, because hyperglycemia also occurs before nursing, preventive measures are recommended throughout the year. PMID:17955898

  4. System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197.

    Science.gov (United States)

    Freckmann, Guido; Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2012-09-01

    The accuracy of systems for self-monitoring of blood glucose is important, as reliable measurement results are a prerequisite for therapeutic decisions. This system accuracy evaluation study was performed according to DIN EN ISO 15197:2003 for 43 Conformité Européenne (CE)-labeled blood glucose (BG) monitoring systems. Measurement results of each system were compared with results of the designated comparison method (manufacturer's measurement procedure): glucose oxidase method (YSI 2300 glucose analyzer) or hexokinase method (Hitachi 917/ cobas 501). Complete assessment according to the International Organization for Standardization (ISO) standard was performed for 34 out of 43 systems, and 27 (79.4%) meet the requirements of the standard, i.e., ≥95% of their results showed at least the minimum acceptable accuracy. For 9 of the 43 systems, complete accuracy assessment was not performed due to an oxygen sensitivity (manufacturer's labeling). The bias (according to Bland and Altman) of all 43 evaluated systems ranged from -14.1% to +12.4%. From the 34 systems completely assessed, 7 systems did not fulfill the minimal accuracy requirements of the ISO standard. The CE mark apparently does not guarantee that all BG systems provide accuracy according to the standard. Because inaccurate systems bear the risk of false therapeutic decisions, regular and standardized evaluation of BG meters and test strips should be requested in order to ensure adherence to quality standards. © 2012 Diabetes Technology Society.

  5. Increasing blood glucose variability is a precursor of sepsis and mortality in burned patients.

    Directory of Open Access Journals (Sweden)

    Alexander N Pisarchik

    Full Text Available High glycemic variability, rather than a mean glucose level, is an important factor associated with sepsis and hospital mortality in critically ill patients. In this retrospective study we analyze the blood glucose data of 172 nondiabetic patients 18-60 yrs old with second and third-degree burns of total body surface area greater than 30% and 5%, respectively, admitted to ICU in 2004-2008. The analysis identified significant association of increasing daily glucose excursion (DELTA accompanied by evident episodes of hyperglycemia (>11 mmol/l and hypoglycemia (<2.8 mmol/l, with sepsis and forthcoming death, even when the mean daily glucose was within a range of acceptable glycemia. No association was found in sepsis complication and hospital mortality with doses of intravenous insulin and glucose infusion. A strong increase in DELTA before sepsis and death is treated as fluctuation amplification near the onset of dynamical instability.

  6. Association between whole blood mercury and glucose intolerance among adult Inuit in Greenland.

    Science.gov (United States)

    Jeppesen, Charlotte; Valera, Beatriz; Nielsen, Nina O; Bjerregaard, Peter; Jørgensen, Marit E

    2015-11-01

    The Arctic diet is partly constituted by traditional food characterized by top predator animals such as whales, walrus, and seals with high mercury content. Mercury exposure has been associated with glucose intolerance in Western populations. We studied the association between whole blood mercury and glucose intolerance in a highly exposed non-Western population Cross-sectional study of 2640 Inuit (18+ years) with information on ancestry, smoking, waist circumference, total energy intake, and physical activity. Mercury, fasting- and 2-h plasma glucose, insulin, and c-peptide were measured in blood. Fasting participants without diabetes were classified into normal glucose tolerance, impaired glucose tolerance, impaired fasting glycemia, or type 2 diabetes. We calculated hepatic insulin resistance with homoeostatic model assessment - insulin resistance index, peripheral insulin sensitivity by ISI0,120., and relative beta cell function by c-peptide/insulin ratio. We conducted adjusted linear- and logistic regression analyses. For an increase in whole blood mercury of 5 µg/L we found a positive association with fasting glucose [% change=0.25 (95% CI: 0.20; 0.30); p<0.001], and 2-h glucose [% change=0.23 (95% CI: 0.05; 0.40); p=0.01]. Mercury was weakly associated with impaired fasting glycemia [OR=1.03 (95% CI: 1.02; 1.05)], and type 2 diabetes [OR=1.02 (95% CI: 1.01; 1.04)]. While the study found a weak but statistically significant association between whole blood mercury and both impaired fasting glycemia and type 2 diabetes, no associations were found with measures of underlying disturbances in glucose homoeostasis. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Preservation of blood glucose homeostasis in slow-senescing somatotrophism-deficient mice subjected to intermittent fasting begun at middle or old age.

    Science.gov (United States)

    Arum, Oge; Saleh, Jamal K; Boparai, Ravneet K; Kopchick, John J; Khardori, Romesh K; Bartke, Andrzej

    2014-06-01

    Poor blood glucose homeostatic regulation is common, consequential, and costly for older and elderly populations, resulting in pleiotrophically adverse clinical outcomes. Somatotrophic signaling deficiency and dietary restriction have each been shown to delay the rate of senescence, resulting in salubrious phenotypes such as increased survivorship. Using two growth hormone (GH) signaling-related, slow-aging mouse mutants we tested, via longitudinal analyses, whether genetic perturbations that increase survivorship also improve blood glucose homeostatic regulation in senescing mammals. Furthermore, we institute a dietary restriction paradigm that also decelerates aging, an intermittent fasting (IF) feeding schedule, as either a short-term or a sustained intervention beginning at either middle or old age, and assess its effects on blood glucose control. We find that either of the two genetic alterations in GH signaling ameliorates fasting hyperglycemia; additionally, both longevity-inducing somatotrophic mutations improve insulin sensitivity into old age. Strikingly, we observe major and broad improvements in blood glucose homeostatic control by IF: IF improves ad libitum-fed hyperglycemia, glucose tolerance, and insulin sensitivity, and reduces hepatic gluconeogenesis, in aging mutant and normal mice. These results on correction of aging-resultant blood glucose dysregulation have potentially important clinical and public health implications for our ever-graying global population, and are consistent with the Longevity Dividend concept.

  8. Assessment of blood glucose predictors: the prediction-error grid analysis.

    Science.gov (United States)

    Sivananthan, Sampath; Naumova, Valeriya; Man, Chiara Dalla; Facchinetti, Andrea; Renard, Eric; Cobelli, Claudio; Pereverzyev, Sergei V

    2011-08-01

    Prediction of the future blood glucose (BG) evolution from continuous glucose monitoring (CGM) data is a promising direction in diabetes therapy management, and several glucose predictors have recently been proposed. This raises the problem of their assessment. There were attempts to use for such assessment the continuous glucose-error grid analysis (CG-EGA), originally developed for CGM devices. However, in the CG-EGA the BG rate of change is estimated from past BG readings, whereas predictors provide BG estimation ahead of time. Therefore, the original CG-EGA should be modified to assess predictors. Here we propose a new version of the CG-EGA, the Prediction-Error Grid Analysis (PRED-EGA). The analysis is based both on simulated data and on data from clinical trials, performed in the European FP7-project "DIAdvisor." Simulated data are used to test the ability of the analyzed CG-EGA modifications to capture erroneous predictions in controlled situation. Real data are used to show the impact of the different CG-EGA versions in the evaluation of a predictor. Using the data of 10 virtual and 10 real subjects and analyzing two different predictors, we demonstrate that the straightforward application of the CG-EGA does not adequately classify the prediction performance. For example, we observed that up to 70% of 20 min ahead predictions in the hyperglycemia region that are classified by this application as erroneous are, in fact, accurate. Moreover, for predictions during hypoglycemia the assessments produced by the straightforward application of the CG-EGA are not only too pessimistic (in up to 60% of cases), but this version is not able to detect real erroneous predictions. In contrast, the proposed modification of the CG-EGA, where the rate of change is estimated on the predicted BG profile, is an adequate metric for the assessment of predictions. We propose a new CG-EGA, the PRED-EGA, for the assessment of glucose predictors. The presented analysis shows that

  9. Association between whole blood mercury and glucose intolerance among adult Inuit in Greenland

    DEFF Research Database (Denmark)

    Jeppesen, Charlotte; Valera, Beatriz; Nielsen, Nina O

    2015-01-01

    OBJECTIVES: The Arctic diet is partly constituted by traditional food characterized by top predator animals such as whales, walrus, and seals with high mercury content. Mercury exposure has been associated with glucose intolerance in Western populations. We studied the association between whole...... blood mercury and glucose intolerance in a highly exposed non-Western population METHODS: Cross-sectional study of 2640 Inuit (18+ years) with information on ancestry, smoking, waist circumference, total energy intake, and physical activity. Mercury, fasting- and 2-h plasma glucose, insulin, and c...

  10. Path modelling of antecedent of diabetes mellitus on blood glucose measurements

    Science.gov (United States)

    Latif, Humaira'Abdul; Hamid, Mohd Rashid Ab; Azizan, Nor Azlinna; Jemain, Abdul Aziz

    2017-05-01

    Diabetes Mellitus (DM) is one of the non-communicable diseases and public health problems facing the worldwide population that includes Malaysia. Hitherto, the prevalence of DM becomes worsening with an estimated of 3.4 million Malaysians are diabetes sufferers and expectedly increasing year by year. Thus, this study is of great importance by regressing the medical factors that affect the blood glucose level using structural equation modelling (SEM). The SEM with partial least squares (PLS) estimation was applied to a secondary data of 644 respondents, aged ≥ 18 years in Malaysia. The data were collected in 2011 by Ministry of Health Malaysia (MOH). The variables under study are blood glucose level, cholesterol level (CL), systolic blood pressure (SBP), diastolic blood pressure (DBP), waist circumference (WC) and body mass index (BMI). From the modelling analysis, it showed that the cholesterol level (CL), systolic blood pressure (SBP) and waist circumference (WC) showed a positive significant relationship p diabetes mellitus among adults.

  11. Smart point-of-care systems for molecular diagnostics based on nanotechnology: whole blood glucose analysis

    Science.gov (United States)

    Devadhasan, Jasmine P.; Kim, Sanghyo

    2015-07-01

    Complementary metal oxide semiconductor (CMOS) image sensors are received great attention for their high efficiency in biological applications. The present work describes a CMOS image sensor-based whole blood glucose monitoring system through a point-of-care (POC) approach. A simple poly-ethylene terephthalate (PET) film chip was developed to carry out the enzyme kinetic reaction at various concentrations of blood glucose. In this technique, assay reagent was adsorbed onto amine functionalized silica (AFSiO2) nanoparticles in order to achieve glucose oxidation on the PET film chip. The AFSiO2 nanoparticles can immobilize the assay reagent with an electrostatic attraction and eased to develop the opaque platform which was technically suitable chip to analyze by the camera module. The oxidized glucose then produces a green color according to the glucose concentration and is analyzed by the camera module as a photon detection technique. The photon number decreases with increasing glucose concentration. The simple sensing approach, utilizing enzyme immobilized AFSiO2 nanoparticle chip and assay detection method was developed for quantitative glucose measurement.

  12. A Microwave Metamaterial Inspired Sensor for Non-Invasive Blood Glucose Monitoring

    Directory of Open Access Journals (Sweden)

    J. Vrba

    2015-12-01

    Full Text Available In this paper, a microwave sensor based on an artificial transmission line is proposed for non-invasive blood glucose monitoring. A corresponding numerical model of the sensor implemented in microstrip technology is created in the commercial full-wave numerical simulation tool COMSOL Multiphysics and virtually tested by means of numerical simulations. Blood-glucose solution models with various blood glucose concentrations are used as a model of a biological tissue under test. Furthermore, a possible methodology for performing non-invasive tests is proposed. Sensitivity of the sensor developed here is compared to a sensor based on a section of a conventional microstrip transmission line of the same length and width.

  13. Mobile Diabetes Intervention Study of Patient Engagement and Impact on Blood Glucose: Mixed Methods Analysis.

    Science.gov (United States)

    Quinn, Charlene Connolly; Butler, Erin C; Swasey, Krystal K; Shardell, Michelle D; Terrin, Michael D; Barr, Erik A; Gruber-Baldini, Ann L

    2018-02-02

    Successful treatment of diabetes includes patient self-management behaviors to prevent or delay complications and comorbid diseases. On the basis of findings from large clinical trials and professional guidelines, diabetes education programs and health providers prescribe daily regimens of glucose monitoring, healthy eating, stress management, medication adherence, and physical activity. Consistent, long-term commitment to regimens is challenging. Mobile health is increasingly being used to assist patients with lifestyle changes and self-management behaviors between provider visits. The effectiveness of mobile health to improve diabetes outcomes depends on patient engagement with a technology, content, or interactions with providers. In the current analysis, we aimed to identify patient engagement themes in diabetes messaging with diabetes providers and determine if differences in engagement in the Mobile Diabetes Intervention Study (MDIS) influenced changes in glycated hemoglobin A 1c (HbA 1c ) over a 1-year treatment period (1.9% absolute decrease in the parent study). In the primary MDIS study, 163 patients were enrolled into 1 of 3 mobile intervention groups or a usual care control group based on their physician cluster randomization assignment. The control group received care from their physicians as usual. Participants in each intervention group had access to a patient portal where they could record monitoring values for blood glucose, blood pressure, medication changes, or other self-management information while also assigned to varying levels of physician access to patient data. Intervention participants could choose to send and receive messages to assigned certified diabetes educators with questions or updates through the secure Web portal. For this secondary analysis, patient engagement was measured using qualitative methods to identify self-care themes in 4109 patient messages. Mixed methods were used to determine the impact of patient engagement on

  14. Gcg-XTEN: an improved glucagon capable of preventing hypoglycemia without increasing baseline blood glucose.

    Directory of Open Access Journals (Sweden)

    Nathan C Geething

    2010-04-01

    Full Text Available While the majority of current diabetes treatments focus on reducing blood glucose levels, hypoglycemia represents a significant risk associated with insulin treatment. Glucagon plays a major regulatory role in controlling hypoglycemia in vivo, but its short half-life and hyperglycemic effects prevent its therapeutic use for non-acute applications. The goal of this study was to identify a modified form of glucagon suitable for prophylactic treatment of hypoglycemia without increasing baseline blood glucose levels.Through application of the XTEN technology, we report the construction of a glucagon fusion protein with an extended exposure profile (Gcg-XTEN. The in vivo half-life of the construct was tuned to support nightly dosing through design and testing in cynomolgus monkeys. Efficacy of the construct was assessed in beagle dogs using an insulin challenge to induce hypoglycemia. Dose ranging of Gcg-XTEN in fasted beagle dogs demonstrated that the compound was biologically active with a pharmacodynamic profile consistent with the designed half-life. Prophylactic administration of 0.6 nmol/kg Gcg-XTEN to dogs conferred resistance to a hypoglycemic challenge at 6 hours post-dose without affecting baseline blood glucose levels. Consistent with the designed pharmacokinetic profile, hypoglycemia resistance was not observed at 12 hours post-dose. Importantly, the solubility and stability of the glucagon peptide were also significantly improved by fusion to XTEN.The data show that Gcg-XTEN is effective in preventing hypoglycemia without the associated hyperglycemia expected for unmodified glucagon. While the plasma clearance of this Gcg-XTEN has been optimized for overnight dosing, specifically for the treatment of nocturnal hypoglycemia, constructs with significantly longer exposure profiles are feasible. Such constructs may have multiple applications such as allowing for more aggressive insulin treatment regimens, treating hypoglycemia due to insulin

  15. Toothbrushing, Blood Glucose and HbA1c: Findings from a Random Survey in Chinese Population

    Science.gov (United States)

    Su, Lingyu; Liu, Wenzhao; Xie, Bingwu; Dou, Lei; Sun, Jun; Wan, Wenjuan; Fu, Xiaoming; Li, Guangyue; Huang, Jiao; Xu, Ling

    2016-01-01

    Both diabetes and periodontal disease are prevalent in China. Poor oral hygiene practice is the major cause of periodontal disease. An association between oral hygiene practice and blood glucose level was reported in individuals with diabetes, but not in the general population. We examined the association in a population-based random survey recruiting 2,105 adults without previously diagnosed diabetes in Chongqing city, China. Plasma glucose and hemoglobin A1c (HbA1c) were measured, and a 2-hour oral glucose tolerance test was conducted for each respondent. Self-reported toothbrushing frequency was used as a proxy for oral hygiene practice. In a linear model controlling for potential confounders (demographic characteristics, socio-economic status, lifestyle risk factors, BMI, dental visit frequency, etc.), urban residents who barely brushed their teeth had an increase of 0.50 (95% CI: 0.10–0.90) mmol/L in fasting plasma glucose, and an increase of 0.26% (0.04–0.47%) in HbA1c, relative to those brushing ≥twice daily; for rural residents, the effects were 0.26 (0.05–0.48) mmol/L in fasting plasma glucose and 0.20% (0.09–0.31%) in HbA1c. Individuals with better oral practice tended to have lower level of blood glucose and HbA1c. Establishing good oral health behavioral habits may be conducive to diabetes prevention and control in the general population. PMID:27385509

  16. Blood plasma separation in ZnO nanoflowers-supported paper based microfluidic for glucose sensing

    Science.gov (United States)

    Muhimmah, Luthviyah Choirotul; Roekmono, Hadi, Harsono; Yuwono, Rio Akbar; Wahyuono, Ruri Agung

    2018-04-01

    Blood plasma separation is essential to analyze and quantify the bio-substances in the human blood and hence, allows for diagnosing various diseases. This paper presents the two layer paper-based microfluidic analytical devices coated with ZnO nanoflowers (ZnO NF-µPAD) for a rapid blood plasma separation and