WorldWideScience

Sample records for blood flow reserve

  1. MR assessment of absolute myocardial blood flow and vasodilator flow reserve in patients with hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Kawada, Nanaka; Sakuma, Hajime; Takeda, Kan; Nakagawa, Tsuyoshi; Yamakado, Tetsu; Nakano, Takeshi [Mie Univ., Tsu (Japan). School of Medicine

    1997-04-01

    Absolute coronary blood flow per myocardial mass and coronary flow reserve for the entire left ventricle were evaluated in normals and in patients with hypertrophic cardiomyopathy (HCM) by using fast cine MR imaging and fast velocity encoded cine (VENC) MR imaging. Nine healthy volunteers and 8 patients with HCM were studied with a 1.5 T imager. Breath-hold cine MR images encompassing the whole left ventricle were acquired on short axis imaging planes in order to evaluate myocardial mass. A fast VENC MR images were obtained to measure blood flow volume in the coronary sinus before and after dipyridamole administration (TR/TE=15/5 ms, FOV=28 x 22 cm, slice thickness=5 mm). Coronary flow reserve was calculated as a ratio of hyperemic to baseline coronary flow volumes. In the baseline state, coronary blood flow per myocardial mass was significantly lower in patients with HCM than in normal myocardium (0.56{+-}0.23 vs. 0.78{+-}0.27 ml/min/g, p<0.05). After dipyridamole administration, coronary blood flow per myocardial mass in patients with HCM increased substantially less than that in healthy subjects (0.99{+-}0.38 vs. 2.22{+-}0.55 ml/min/g, p<0.01), resulting in the significantly decreased coronary flow reserve ratio in HCM in comparison with that in normal myocardium (1.86{+-}0.56 vs. 3.11{+-}1.37, p<0.05). In conclusion, breath-hold velocity encoded cine MR imaging is a noninvasive technique which can provide assessments of altered coronary blood flow volume per myocardial mass and vasodilator flow reserve in patients with HCM. (author)

  2. Profound spatial heterogeneity of coronary reserve. Discordance between patterns of resting and maximal myocardial blood flow.

    Science.gov (United States)

    Austin, R E; Aldea, G S; Coggins, D L; Flynn, A E; Hoffman, J I

    1990-08-01

    We examined the ability of individual regions of the canine left ventricle to increase blood flow relative to baseline rates of perfusion. Regional coronary flow was measured by injecting radioactive microspheres over 90 seconds in seven anesthetized mongrel dogs. Preliminary experiments demonstrated a correlation between the regional distributions of blood flow during asphyxia and pharmacological vasodilatation with adenosine (mean r = 0.75; 192 regions in each of two dogs), both of which resulted in increased coronary flow. Subsequent experiments, during which coronary perfusion pressure was held constant at 80 mm Hg, examined the pattern of blood flow in 384 regions (mean weight, 106 mg) of the left ventricular free wall during resting flow and during maximal coronary flow effected by intracoronary adenosine infusion. We found that resting and maximal flow patterns were completely uncorrelated to each other in a given dog (mean r = 0.06, p = NS; n = 3 dogs). Furthermore, regional coronary reserve, defined as the ratio of maximal to resting flow, ranged from 1.75 (i.e., resting flow was 57% of maximum) to 21.9 (resting flow was 4.5% of maximum). Thus, coronary reserve is spatially heterogeneous and determined by two distinct perfusion patterns: the resting (control) pattern and the maximal perfusion pattern. Normal hearts, therefore, contain small regions that may be relatively more vulnerable to ischemia. This may explain the patchy nature of infarction with hypoxia and at reduced perfusion pressures as well as the difficulty of using global parameters to predict regional ischemia. Despite the wide dispersion of coronary reserve, we found, by autocorrelation analysis, that reserve in neighboring regions (even when separated by a distance of several tissue samples) was significantly correlated. This also applied to patterns of resting myocardial flow. Thus, both resting coronary blood flow and reserve appear to be locally continuous and may define functional

  3. Quantification of myocardial blood flow and blood flow reserve in the presence of arterial dispersion: a simulation study.

    Science.gov (United States)

    Schmitt, Melanie; Viallon, Magalie; Thelen, Manfred; Schreiber, Wolfgang G

    2002-04-01

    Myocardial blood flow (MBF) can be quantified using dynamic T1-weighted MRI of diffusible tracers and a mathematical model of underlying vasculature. Quantification of MBF by means of T1- weighted MRI requires knowledge of the arterial input function (AIF). The AIF can be estimated from the left ventricular (LV) cavity. However, dispersion may occur between the LV and the tissue of interest because of the laminar blood flow profiles, branching of venules, and because of stenosis. To evaluate the influence of dispersion on the results of MBF quantification, a simulation study was performed. The dispersion was described as a convolution of the AIF with an exponential residue function. Synthetic tissue and AIF curves were analyzed and the derived parameters fit to the simulated parameters. The results show that an unaccounted dispersion may result in a systematic underestimation of MBF up to approximately 50%. Underestimation increases with increasing dispersion and with increasing MBF. Assuming equal dispersion at rest and during hyperemia, myocardial perfusion reserve (MPR) estimates are also susceptible to underestimation of approximately 20%. An unaccounted dispersion therefore can lead to systematic underestimation of both blood flow and perfusion reserve.

  4. Endothelial and non-endothelial coronary blood flow reserve and left ventricular dysfunction in systemic hypertension

    Directory of Open Access Journals (Sweden)

    Aloísio Marchi Rocha

    2009-04-01

    Full Text Available OBJECTIVES: We evaluated the impairment of endothelium-dependent and endothelium-independent coronary blood flow reserve after administration of intracoronary acetylcholine and adenosine, and its association with hypertensive cardiac disease. INTRODUCTION: Coronary blood flow reserve reduction has been proposed as a mechanism for the progression of compensated left ventricular hypertrophy to ventricular dysfunction. METHODS: Eighteen hypertensive patients with normal epicardial coronary arteries on angiography were divided into two groups according to left ventricular fractional shortening (FS. Group 1 (FS >0.25: n=8, FS=0.29 ± 0.03; Group 2 (FS <0.25: n=10, FS= 0.17 ± 0.03. RESULTS: Baseline coronary blood flow was similar in both groups (Group 1: 80.15 ± 26.41 mL/min, Group 2: 100.09 ± 21.51 mL/min, p=NS. In response to adenosine, coronary blood flow increased to 265.1 ± 100.2 mL/min in Group 1 and to 300.8 ± 113.6 mL/min (p <0.05 in Group 2. Endothelium-independent coronary blood flow reserve was similar in both groups (Group 1: 3.31 ± 0.68 and Group 2: 2.97 ± 0.80, p=NS. In response to acetylcholine, coronary blood flow increased to 156.08 ± 36.79 mL/min in Group 1 and to 177.8 ± 83.6 mL/min in Group 2 (p <0.05. Endothelium-dependent coronary blood flow reserve was similar in the two groups (Group 1: 2.08 ± 0.74 and group Group 2: 1.76 ± 0.61, p=NS. Peak acetylcholine/peak adenosine coronary blood flow response (Group 1: 0.65 ± 0.27 and Group 2: 0.60 ± 0.17 and minimal coronary vascular resistance (Group 1: 0.48 ± 0.21 mmHg/mL/min and Group 2: 0.34 ± 0.12 mmHg/mL/min were similar in both groups (p= NS. Casual diastolic blood pressure and end-systolic left ventricular stress were independently associated with FS. CONCLUSIONS: In our hypertensive patients, endothelium-dependent and endothelium-independent coronary blood flow reserve vasodilator administrations had similar effects in patients with either normal or decreased left

  5. Effect of streptozotocin-induced diabetes on myocardial blood flow reserve assessed by myocardial contrast echocardiography in rats

    OpenAIRE

    Weytjens Caroline; Garbar Christian; Degaillier Céline; Hernot Sophie; Droogmans Steven; Cosyns Bernard; Roosens Bram; Schoors Danny; Lahoutte Tony; Franken Philippe R; Van Camp Guy

    2008-01-01

    Abstract The role of structural and functional abnormalities of small vessels in diabetes cardiomyopathy remains unclear. Myocardial contrast echocardiography allows the quantification of myocardial blood flow at rest and during dipyridamole infusion. The aim of the study was to determine the myocardial blood flow reserve in normal rats compared with Streptozotocin-induced diabetic rats using contrast echocardiography. Methods We prospectively studied 40 Wistar rats. Diabetes was induced by ...

  6. Quantitative assessment of blood flow reserve using {sup 99m}Tc-HMPAO in carotid stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Garai, I.; Varga, J.; Galuska, L. [Department of Nuclear Medicine, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Szomjak, E. [3. Department of Internal Medicine, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Toth, C.; Olvaszto, S. [1. Department of Surgery, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Bank, J. [Department of Neurology, Kenezy Hospital (Hungary); Ficzere, A. [Department of Neurology, University of Debrecen Medical and Health Centre, Debrecen (Hungary)

    2002-02-01

    Dynamic imaging of the inflow of technetium-99m hexamethylpropylene amine oxime (HMPAO) to the brain has been proved to allow estimation of the hemispherical cerebral blood flow (CBF) using the Patlak plot. In this study, we compared the hemispherical CBF (in ml/min/100 g) of different patient groups. A total of 25 patients (comprising 13 with migraine and 12 scheduled for endarterectomy owing to angiographically confirmed severe stenosis of the internal carotid artery on at least one side) underwent baseline and acetazolamide {sup 99m}Tc-HMPAO brain perfusion studies. In addition, acetazolamide {sup 99m}Tc-HMPAO studies were performed in 12 healthy subjects (no baseline study was performed for ethical reasons.) Dynamic studies were acquired by means of a dual-detector gamma camera with a large field of view (HELIX, Elscint). Special difference images were created to make definition of the aortic arch and hemispherical brain regions easier and more reproducible. A semi-automatic method was developed to determine the transit time from the aorta to the brain, making the generation of the Patlak plot even more robust. The baseline CBF values did not significantly depend on the disease (P>0.1), whereas the CBF values obtained after acetazolamide provocation did do so (ANOVA, P<0.001). Patients suffering from migraine showed a significant increase in global CBF values after acetazolamide provocation (paired t test, P<0.05), but we could not find any effect of the provocation in patients awaiting carotid endarterectomy, indicating a lack of cerebrovascular reserve capacity. Comparison of the results of the acetazolamide study in patients and the control group revealed the CBF values to be significantly lower in patients with carotid stenosis (two-sample t-test, P<0.001), but not in those with migraine (P>0.1). In summary, using quantitative analysis of {sup 99m}Tc-HMPAO brain studies we could objectively compare the CBF of patients suffering from different diseases

  7. Cerebral blood flow and cerebrovascular reserve capacity: estimation by dynamic magnetic resonance imaging.

    Science.gov (United States)

    Schreiber, W G; Gückel, F; Stritzke, P; Schmiedek, P; Schwartz, A; Brix, G

    1998-10-01

    We have developed a new method for estimation of regional CBF (rCBF) and cerebrovascular reserve capacity on a pixel-by-pixel basis by means of dynamic magnetic resonance imaging (MRI). Thirteen healthy volunteers, 8 patients with occlusion and/or high grade stenosis of the internal carotid artery (ICA), and 2 patients with acute stroke underwent dynamic susceptibility-weighted contrast enhanced MRI. Using principles of indicator dilution theory and deconvolution analysis, maps of rCBF, regional cerebral blood volume, and of the mean transit time (MTT) were calculated. In patients with ICA occlusion/stenosis, cerebrovascular reserve capacity was assessed by the rCBF increase after acetazolamide stimulation. Mean gray and white matter rCBF values in normals were 67.1 and 23.7 mL x 100 g(-1) x min(-1), respectively. Before acetazolamide stimulation, six of eight patients with ICA occlusions showed decreased rCBF values; and in seven patients increased MTT values were observed in tissue ipsilateral to the occlusion. After acetazolamide stimulation, decreased cerebrovascular reserve capacity was observed in five of eight patients with ICA occlusion. In acute stroke, rCBF in the central core of ischemia was less than 8 mL x 100 g(-1) x min(-1). In peri-infarct tissue, rCBF and MTT were higher than in unaffected tissue but rCBF was normal. Dynamic MRI provides important clinical information on the hemodynamic state of brain tissue in patients with occlusive cerebrovascular disease or acute stroke.

  8. Impaired myocardial blood flow reserve in subjects with metabolic syndrome analyzed using positron emission tomography and N-13 labeled ammonia

    Energy Technology Data Exchange (ETDEWEB)

    Teragawa, Hiroki; Kihara, Yasuki [Hiroshima University Graduate School of Biomedical Sciences, Department of Cardiovascular Medicine, Hiroshima (Japan); Morita, Koichi; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Shishido, Hiroki; Otsuka, Nobuaki; Hirokawa, Yutaka [Hiroshima Heiwa Clinic, Hiroshima (Japan); Chayama, Kazuaki [Hiroshima University Graduate School of Biomedical Sciences, Department of Molecular Science and Medicine, Hiroshima (Japan)

    2010-02-15

    Coronary vasomotor response might be impaired in metabolic syndrome (MS); however, the precise abnormality has not been elucidated. The aim of this study was to assess coronary-vasomotor response in MS subjects using N-13 labeled ammonia and positron emission tomography. Myocardial blood flow (MBF) was measured at rest and during adenosine infusion in MS subjects (n = 13, MS group) with no definite evidence of heart disease and in subjects without MS (n = 14, non-MS group). Coronary vascular resistance (CVR) was calculated by dividing the mean aortic blood pressure by MBF. Myocardial blood flow reserve (MFR) was calculated as the ratio of the MBF during adenosine infusion to that during rest. Blood chemical parameters were measured to evaluate their relationship with MFR. During adenosine infusion, MBF was lower (p = 0.0085) and CVR higher (p = 0.0128) in the MS group than in the non-MS group and MFR was significantly lower in the MS group than in the non-MS group (2.13 {+-} 0.99 vs. 3.38 {+-} 0.95, p = 0.0027). Multivariate analysis demonstrated that the homeostasis model assessment-insulin resistance (p < 0.05) and the presence of hypertension (p < 0.05) were independent determinants of MFR. The results indicate that MFR was impaired in MS subjects, suggesting that an abnormal coronary microvascular response occurred in these subjects. This abnormality may have been partially due to insulin resistance and hypertension. (orig.)

  9. Cerebral blood flow and cerebrovascular reserve capacity in patients with occlusion or severe stenosis of cerebral arterial trunk

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, Shinya; Tanaka, Akira; Nakayama, Yoshiya; Tomonaga, Masamichi [Fukuoka Univ., Chikushino (Japan). Chikushi Hospital

    1997-12-01

    The cerebral blood flow (CBF) and the cerebrovascular reserve capacity (CVRC) were sequentially measured using a xenon enhanced CT scan in patients with transient ischemic attack or minor stroke due to an occlusion or a severe stenosis of the cerebral arterial trunk. The patients consisted of twelve males and one female ranging from 37 to 71 years of age (53 years on average). The vascular lesion was located in the internal carotid artery (7 patients) and in the middle cerebral artery (6 patients). Eleven patients received antiplatelet drug therapy, while two other patients underwent STA-MCA anastomosis. The CBF measurements were initially done within one month after the attack and then from 6 to 24 months (12 months on average) after the first study. Only one of 13 patients demonstrated a reattack during the period of observation and the CVRC decreased to 0% from the 14% level observed prior to the reattack, although the CBF was preserved. In the other twelve patients without a reattack, the CVRC was found to improve to 29.4% from 9.9% with statistical significance, even though the CBF remained the same in the first study. This study suggests hemodynamic insult to be closely related to the decreased in the CVRC, while STA-MCA anastomosis does not for prevent hemodynamic reattack based on a decrease in the CVRC in the early stage. (author)

  10. Impact of uncontrolled blood pressure on diagnostic accuracy of coronary flow reserve for detecting significant coronary stenosis in hypertensive patients

    Institute of Scientific and Technical Information of China (English)

    LI Wei-hong; XU Wei-xian; LI Zhao-ping; LI Cui-ping; WANG Xin-yu; HE Li-yun; ZHAO Wei

    2013-01-01

    Baciground Impaired coronary flow reserve (CFR) in patients with hypertension may be caused by epicardial coronary stenosis or microvascular dysfunction.Antihypertensive treatment has been shown to improve coronary microvascular dysfunction.The aim of this study was to evaluate the impact of uncontrolled blood pressure (BP) on diagnostic accuracy of CFR for detecting significant coronary stenosis.Methods A total of 98 hypertensive patients scheduled for coronary angiography (CAG) due to chest pain were studied.Of them,45 patients had uncontrolled BP (defined as the office BP >140/90 mmHg (1 mmHg=0.133 kPa) in general hypertensive patients,or >130/80 mmHg in hypertensive individuals with diabetes mellitus),and the remaining 53 patients had well-controlled BP.CFR was measured in the left anterior descending coronary artery (LAD) during adenosine triphosphate-induced hyperemia by non-invasive transthoracic Doppler echocardiography (TTDE) within 48 hours prior to CAG.Significant LAD stenosis was defined as >70% luminal narrowing.Diagnostic accuracy of CFR for detecting significant coronary stenosis was analyzed with a receiver operating characteristic analysis.Results CFR was significantly lower in patients with uncontrolled BP than in those with well-controlled BP (2.1±0.6 vs.2.6±0.9,P <0.01).Multivariate linear regression analysis of the study showed that the value of CFR was independently associated with the angiographically determined degree of LAD stenosis (β=-0.445,P <0.0001) and the presence of uncontrolled BP (β=-0.272,P=0.014).With a receiver operating characteristic analysis,CFR <2.2 was the optimal cut-off value for detecting LAD stenosis in all hypertensive patients (AUC 0.83,95%C/0.75-0.91) with a sensitivity of 75%,a specificity of 78%,and an accuracy of 77%.A significant reduction of diagnostic specificity was observed in patients with uncontrolled BP compared with those with well-controlled BP (67% vs.93%,P=0

  11. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  12. Relationship between HgbA1c and Myocardial Blood Flow Reserve in Patients with Type 2 Diabetes Mellitus: Noninvasive Assessment Using Real-Time Myocardial Perfusion Echocardiography

    Directory of Open Access Journals (Sweden)

    Runqing Huang

    2014-01-01

    Full Text Available To study the relationship between glycosylated hemoglobin (HgbA1c and myocardial perfusion in type 2 diabetes mellitus (T2DM patients, we prospectively enrolled 24 patients with known or suspected coronary artery disease (CAD who underwent adenosine stress by real-time myocardial perfusion echocardiography (RTMPE. HgbA1c was measured at time of RTMPE. Microbubble velocity (β min−1, myocardial blood flow (MBF, mL/min/g, and myocardial blood flow reserve (MBFR were quantified. Quantitative MCE analysis was feasible in all patients (272/384 segments, 71%. Those with HgbA1c > 7.1% had significantly lower βreserve and MBFR than those with HgbA1c ≤ 7.1% (P 2 as normal, HgbA1c > 7.1% significantly increased the risk for abnormal MBFR, (adjusted odds ratio: 1.92, 95% CI: 1.12–3.35, P=0.02. Optimal glycemic control is associated with preservation of MBFR as determined by RTMPE, in T2DM patients at risk for CAD.

  13. The effect of EC-IC bypass surgery on resting cerebral blood flow and cerebrovascular reserve capacity studied with stable Xe-CT and acetazolamide test

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, T.; Kashiwagi, S.; Nakano, S.; Takasago, T.; Abiko, S.; Shiroyama, Y.; Hayashi, M.; Ito, H. (Yamaguchi Univ. School of Medicine (Japan). Dept. of Neurosurgery)

    1991-06-01

    Cerebral blood flow (CBF) and cerebrovascular reserve capacity (CRC) were measured by stable xenon computerized tomography (Xe-CT) and acetazolamide test in 15 patients with cerebrovascular disease before and after extracranial-intracranial (EC-IC) bypass surgery for minor stroke, reversible ischemic neurological deficit or transient ischemic attack. All had angiographically shown occlusive lesions of the major arterial trunk. In the present series, global analysis showed that the bypass did not increase the resting rCBF, but did increase the rCRC. We divided the patients into four groups according to the preoperative resting rCBF and rCRC. All 3 patients with normal resting rCBF and reduced rCRC showed postoperative improvement of rCRC. Of 6 patients with reduced CBF and reduced CRC, three had postoperative increase in resting CBF and four had increased CRC. One of two patients with reduced CBF and normal CRC showed only an increase in CRC. We propose that reduced CRC or reduced CBF with reduced CRC are criteria for selection of candidates for bypass surgery. We conclude that Xe-CT with the Diamox test is a useful and simple method for evaluating cerebral hemodynamics. Preoperative grouping with a combination of preoperative resting rCBF and preoperative rCRC is useful for predicting the effect of EC-IC bypass surgery. (orig.).

  14. Inability of coronary blood flow reserve measurements to assess the efficacy of coronary angioplasty in the first 24 hours in unselected patients

    NARCIS (Netherlands)

    G-J. Laarman (GertJan); P.W.J.C. Serruys (Patrick); H. Suryapranata (Harry); M.J.B.M. van den Brand (Marcel); P.R. Jonkers; P.J. de Feyter (Pim)

    1991-01-01

    textabstractTo determine functional and anatomic changes in the first 24 hours after coronary angioplasty, we studied at random 15 patients (9 men, mean age 60 years) who underwent coronary angioplasty of 16 coronary arteries. Quantitative coronary angiography and coronary flow reserve measurements

  15. Clinical and experimental aspects of functional and flow reserve of the myocardium

    NARCIS (Netherlands)

    E.O. McFalls (Edward)

    1991-01-01

    textabstractBasic research over the past 50 years has provided the clinician with important concepts for understanding human coronary physiology. One such tool is the determination of coronary blood flow reserve. Defined as the ratio of maximal to resting coronary flow, flow reserve may be helpful i

  16. Blood flow and microgravity

    Science.gov (United States)

    Bureau, Lionel; Coupier, Gwennou; Dubois, Frank; Duperray, Alain; Farutin, Alexander; Minetti, Christophe; Misbah, Chaouqi; Podgorski, Thomas; Tsvirkun, Daria; Vysokikh, Mikhail

    2017-01-01

    The absence of gravity during space flight can alter cardio-vascular functions partially due to reduced physical activity. This affects the overall hemodynamics, and in particular the level of shear stresses to which blood vessels are submitted. Long-term exposure to space environment is thus susceptible to induce vascular remodeling through a mechanotransduction cascade that couples vessel shape and function with the mechanical cues exerted by the circulating cells on the vessel walls. Central to such processes, the glycocalyx - i.e. the micron-thick layer of biomacromolecules that lines the lumen of blood vessels and is directly exposed to blood flow - is a major actor in the regulation of biochemical and mechanical interactions. We discuss in this article several experiments performed under microgravity, such as the determination of lift force and collective motion in blood flow, and some preliminary results obtained in artificial microfluidic circuits functionalized with endothelium that offer interesting perspectives for the study of the interactions between blood and endothelium in healthy condition as well as by mimicking the degradation of glycocalyx caused by long space missions. A direct comparison between experiments and simulations is discussed. xml:lang="fr"

  17. Resting cerebral blood flow

    Science.gov (United States)

    Ances, B M.; Sisti, D; Vaida, F; Liang, C L.; Leontiev, O; Perthen, J E.; Buxton, R B.; Benson, D; Smith, D M.; Little, S J.; Richman, D D.; Moore, D J.; Ellis, R J.

    2009-01-01

    Objective: HIV enters the brain soon after infection causing neuronal damage and microglial/astrocyte dysfunction leading to neuropsychological impairment. We examined the impact of HIV on resting cerebral blood flow (rCBF) within the lenticular nuclei (LN) and visual cortex (VC). Methods: This cross-sectional study used arterial spin labeling MRI (ASL-MRI) to measure rCBF within 33 HIV+ and 26 HIV− subjects. Nonparametric Wilcoxon rank sum test assessed rCBF differences due to HIV serostatus. Classification and regression tree (CART) analysis determined optimal rCBF cutoffs for differentiating HIV serostatus. The effects of neuropsychological impairment and infection duration on rCBF were evaluated. Results: rCBF within the LN and VC were significantly reduced for HIV+ compared to HIV− subjects. A 2-tiered CART approach using either LN rCBF ≤50.09 mL/100 mL/min or LN rCBF >50.09 mL/100 mL/min but VC rCBF ≤37.05 mL/100 mL/min yielded an 88% (29/33) sensitivity and an 88% (23/26) specificity for differentiating by HIV serostatus. HIV+ subjects, including neuropsychologically unimpaired, had reduced rCBF within the LN (p = 0.02) and VC (p = 0.001) compared to HIV− controls. A temporal progression of brain involvement occurred with LN rCBF significantly reduced for both acute/early (<1 year of seroconversion) and chronic HIV-infected subjects, whereas rCBF in the VC was diminished for only chronic HIV-infected subjects. Conclusion: Resting cerebral blood flow (rCBF) using arterial spin labeling MRI has the potential to be a noninvasive neuroimaging biomarker for assessing HIV in the brain. rCBF reductions that occur soon after seroconversion possibly reflect neuronal or vascular injury among HIV+ individuals not yet expressing neuropsychological impairment. GLOSSARY AEH = acute/early HIV infection; ANOVA = analysis of variance; ASL-MRI = arterial spin labeling MRI; CART = classification and regression tree; CBF = cerebral blood flow; CH = chronic HIV

  18. Reserve, flowing electrolyte, high rate lithium battery

    Science.gov (United States)

    Puskar, M.; Harris, P.

    Flowing electrolyte Li/SOCl2 tests in single cell and multicell bipolar fixtures have been conducted, and measurements are presented for electrolyte flow rates, inlet and outlet temperatures, fixture temperatures at several points, and the pressure drop across the fixture. Reserve lithium batteries with flowing thionyl-chloride electrolytes are found to be capable of very high energy densities with usable voltages and capacities at current densities as high as 500 mA/sq cm. At this current density, a battery stack 10 inches in diameter is shown to produce over 60 kW of power while maintaining a safe operating temperature.

  19. Nonuniform loss of regional flow reserve during myocardial ischemia in dogs.

    Science.gov (United States)

    Coggins, D L; Flynn, A E; Austin, R E; Aldea, G S; Muehrcke, D; Goto, M; Hoffman, J I

    1990-08-01

    To determine whether coronary vasodilator reserve that persists during myocardial ischemia is present in all left ventricular regions, we measured regional blood flow in 192 left ventricular pieces (mean weight, 201 mg) in each of eight dogs by using radioactive microspheres while perfusing the left main coronary artery at 70, 50, 40, and 30 mm Hg. Flows were measured before and during adenosine infusion to determine flow reserve. Perfusion at 40 and 30 mm Hg produced ischemia in all dogs. At 70 mm Hg, 100% of left ventricular regions had significant flow reserve, compared with 92%, 55%, and 8% during perfusion at 50, 40, and 30 mm Hg, respectively. A greater amount of flow reserve and a greater number of regions responded to adenosine in the subepicardium than in the subendocardium at 50, 40, and 30 mm Hg. We conclude that coronary flow reserve persists in only a subset of left ventricular regions during ischemia and that the number of regions with persistent flow reserve decreases with perfusion pressure. These findings may best be explained by a model in which regional ischemia is a maximal coronary vasodilator and persistent pharmacological vasodilator reserve seen when global markers indicate ischemia simply reflects persistent endogenous flow reserve in myocardial regions not yet ischemic.

  20. Local Control of Blood Flow

    Science.gov (United States)

    Clifford, Philip S.

    2011-01-01

    Organ blood flow is determined by perfusion pressure and vasomotor tone in the resistance vessels of the organ. Local factors that regulate vasomotor tone include myogenic and metabolic autoregulation, flow-mediated and conducted responses, and vasoactive substances released from red blood cells. The relative importance of each of these factors…

  1. Blood Flow in the Microcirculation

    Science.gov (United States)

    Secomb, Timothy W.

    2017-01-01

    The microcirculation is an extensive network of microvessels that distributes blood flow throughout living tissues. Reynolds numbers are much less than 1, and the equations of Stokes flow apply. Blood is a suspension of cells with dimensions comparable to microvessel diameters. Highly deformable red blood cells, which transport oxygen, have a volume concentration (hematocrit) of 40–45% in humans. In the narrowest capillaries, these cells move in single file with a surrounding lubricating layer of plasma. In larger vessels, the red blood cells migrate toward the centerline, reducing the resistance to blood flow. Vessel walls are coated with a layer of macromolecules that restricts flow. At diverging bifurcations, hematocrit is not evenly distributed in the downstream vessels. Other particles are driven toward the walls by interactions with red blood cells. These physiologically important phenomena are discussed here from a fluid mechanical perspective.

  2. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  3. Neuromodulation of cerebral blood flow

    NARCIS (Netherlands)

    ter Laan, Mark

    2014-01-01

    Dit proefschrift behandelt de modulatie van de cerebrale doorbloeding (cerebral blood flow, CBF) door cervicale elektrische stimulatie en de aanname dat het sympathisch zenuwstelsel hierin een specifieke rol speelt. Enkele resultaten met cervicale ruggenmergsstimulatie (spinal cord stimulation, SCS)

  4. Hyperhomocysteinemia decreases bone blood flow

    Directory of Open Access Journals (Sweden)

    Neetu T

    2011-01-01

    Full Text Available Neetu Tyagi*, Thomas P Vacek*, John T Fleming, Jonathan C Vacek, Suresh C TyagiDepartment of Physiology and Biophysics, School of Medicine, University of Louisville, Louisville, KY, USA *These authors have equal authorshipAbstract: Elevated plasma levels of homocysteine (Hcy, known as hyperhomocysteinemia (HHcy, are associated with osteoporosis. A decrease in bone blood flow is a potential cause of compromised bone mechanical properties. Therefore, we hypothesized that HHcy decreases bone blood flow and biomechanical properties. To test this hypothesis, male Sprague–Dawley rats were treated with Hcy (0.67 g/L in drinking water for 8 weeks. Age-matched rats served as controls. At the end of the treatment period, the rats were anesthetized. Blood samples were collected from experimental or control rats. Biochemical turnover markers (body weight, Hcy, vitamin B12, and folate were measured. Systolic blood pressure was measured from the right carotid artery. Tibia blood flow was measured by laser Doppler flow probe. The results indicated that Hcy levels were significantly higher in the Hcy-treated group than in control rats, whereas vitamin B12 levels were lower in the Hcy-treated group compared with control rats. There was no significant difference in folate concentration and blood pressure in Hcy-treated versus control rats. The tibial blood flow index of the control group was significantly higher (0.78 ± 0.09 flow unit compared with the Hcy-treated group (0.51 ± 0.09. The tibial mass was 1.1 ± 0.1 g in the control group and 0.9 ± 0.1 in the Hcy-treated group. The tibia bone density was unchanged in Hcy-treated rats. These results suggest that Hcy causes a reduction in bone blood flow, which contributes to compromised bone biomechanical properties.Keywords: homocysteine, tibia, bone density

  5. Chaotic advection in blood flow.

    Science.gov (United States)

    Schelin, A B; Károlyi, Gy; de Moura, A P S; Booth, N A; Grebogi, C

    2009-07-01

    In this paper we argue that the effects of irregular chaotic motion of particles transported by blood can play a major role in the development of serious circulatory diseases. Vessel wall irregularities modify the flow field, changing in a nontrivial way the transport and activation of biochemically active particles. We argue that blood particle transport is often chaotic in realistic physiological conditions. We also argue that this chaotic behavior of the flow has crucial consequences for the dynamics of important processes in the blood, such as the activation of platelets which are involved in the thrombus formation.

  6. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1......) identification of the extent of a multivessel coronary artery disease (CAD) burden, 2) patients with balanced 3-vessel CAD, 3) patients with subclinical CAD, and 4) patients with regional flow variance, despite of a high global MFR. A more accurate assessment of the ischemic burden in patients with intermediate...

  7. Magnetohydrodynamics of blood flow.

    Science.gov (United States)

    Keltner, J R; Roos, M S; Brakeman, P R; Budinger, T F

    1990-10-01

    The changes in hydrostatic pressure and electrical potentials across vessels in the human vasculature in the presence of a large static magnetic field are estimated to determine the feasibility of in vivo NMR spectroscopy at fields as high as 10 T.A 10-T magnetic field changes the vascular pressure in a model of the human vasculature by less than 0.2%. An exact solution to the magnetohydrodynamic equations describing a conducting fluid flowing transverse to a static magnetic field in a nonconducting, straight, circular tube is used. This solution is compared to an approximate solution that assumes that no magnetic fields are induced in the fluid and that has led previous investigators to predict significant biological effects from static magnetic fields. Experimental results show that the exact solution accurately predicts the magnetohydrodynamic slowing of 15% NaCl flowing transverse to 2.3- and 4.7-T magnetic fields for fluxes below 0.5 liter/min while the approximate solution predicts a much more retarded flow.

  8. Cerebral blood-flow tomography

    DEFF Research Database (Denmark)

    Lassen, N A; Henriksen, L; Holm, S;

    1983-01-01

    Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used......., and with low radiation exposure to patient and personnel. On the other hand, IMP gives an image of slightly higher resolution. It also introduces a new class of iodinated brain-seeking compounds allowing, perhaps, imaging of other functions more important than mere blood flow.......Tomographic maps of local cerebral blood flow (CBF) were obtained with xenon-133 and with isopropyl-amphetamine-iodine-123 (IMP) in 11 subjects: one normal, two tumor cases, and eight cerebrovascular cases. A highly sensitive four-face, rapidly rotating, single-photon emission tomograph was used...

  9. Association of Coronary Stenosis and Plaque Morphology With Fractional Flow Reserve and Outcomes

    DEFF Research Database (Denmark)

    Ahmadi, Amir; Stone, Gregg W; Leipsic, Jonathon

    2016-01-01

    IMPORTANCE: Obstructive coronary lesions with reduced luminal dimensions may result in abnormal regional myocardial blood flow as assessed by stress-induced myocardial perfusion imaging or a significant fall in distal perfusion pressure with hyperemia-induced vasodilatation (fractional flow reserve......: Having a normal FFR requires unimpaired vasoregulatory ability and significant luminal stenosis. Therefore, FFR should identify lesions that are unlikely to possess large necrotic core, rendering them safe for treatment with medical therapy alone. Further studies are warranted to determine whether...

  10. Ocular Blood Flow Autoregulation Mechanisms and Methods

    Directory of Open Access Journals (Sweden)

    Xue Luo

    2015-01-01

    Full Text Available The main function of ocular blood flow is to supply sufficient oxygen and nutrients to the eye. Local blood vessels resistance regulates overall blood distribution to the eye and can vary rapidly over time depending on ocular need. Under normal conditions, the relation between blood flow and perfusion pressure in the eye is autoregulated. Basically, autoregulation is a capacity to maintain a relatively constant level of blood flow in the presence of changes in ocular perfusion pressure and varied metabolic demand. In addition, ocular blood flow dysregulation has been demonstrated as an independent risk factor to many ocular diseases. For instance, ocular perfusion pressure plays key role in the progression of retinopathy such as glaucoma and diabetic retinopathy. In this review, different direct and indirect techniques to measure ocular blood flow and the effect of myogenic and neurogenic mechanisms on ocular blood flow are discussed. Moreover, ocular blood flow regulation in ocular disease will be described.

  11. Ocular Blood Flow Autoregulation Mechanisms and Methods

    OpenAIRE

    Xue Luo; Yu-meng Shen; Meng-nan Jiang; Xiang-feng Lou; Yin Shen

    2015-01-01

    The main function of ocular blood flow is to supply sufficient oxygen and nutrients to the eye. Local blood vessels resistance regulates overall blood distribution to the eye and can vary rapidly over time depending on ocular need. Under normal conditions, the relation between blood flow and perfusion pressure in the eye is autoregulated. Basically, autoregulation is a capacity to maintain a relatively constant level of blood flow in the presence of changes in ocular perfusion pressure and va...

  12. Turbulent flow as a cause for underestimating coronary flow reserve measured by Doppler guide wire

    Directory of Open Access Journals (Sweden)

    Richartz Barbara M

    2006-03-01

    Full Text Available Abstract Background Doppler-tipped coronary guide-wires (FW are well-established tools in interventional cardiology to quantitatively analyze coronary blood flow. Doppler wires are used to measure the coronary flow velocity reserve (CFVR. The CFVR remains reduced in some patients despite anatomically successful coronary angioplasty. It was the aim of our study to test the influence of changes in flow profile on the validity of intra-coronary Doppler flow velocity measurements in vitro. It is still unclear whether turbulent flow in coronary arteries is of importance for physiologic studies in vivo. Methods We perfused glass pipes of defined inner diameters (1.5 – 5.5 mm with heparinized blood in a pulsatile flow model. Laminar and turbulent flow profiles were achieved by varying the flow velocity. The average peak velocity (APV was recorded using 0.014 inch FW. Flow velocity measurements were also performed in 75 patients during coronary angiography. Coronary hyperemia was induced by intra-coronary injection of adenosine. The APV maximum was taken for further analysis. The mean luminal diameter of the coronary artery at the region of flow velocity measurement was calculated by quantitative angiography in two orthogonal planes. Results In vitro, the measured APV multiplied with the luminal area revealed a significant correlation to the given perfusion volumes in all diameters under laminar flow conditions (r2 > 0.85. Above a critical Reynolds number of 500 – indicating turbulent flow – the volume calculation derived by FW velocity measurement underestimated the actual rate of perfusion by up to 22.5 % (13 ± 4.6 %. In vivo, the hyperemic APV was measured irrespectively of the inherent deviation towards lower velocities. In 15 of 75 patients (20% the maximum APV exceeded the velocity of the critical Reynolds number determined by the in vitro experiments. Conclusion Doppler guide wires are a valid tool for exact measurement of coronary flow

  13. [Role of measurement of fractional flow reserve in coronary artery atherosclerosis].

    Science.gov (United States)

    Kopylovi, F Yu; Bykova, A A; Vasilevsky, Yu V; Simakov, S S

    2015-01-01

    The paper considers coronary flow in health and coronary flow autoregulation in health and disease. It gives basic methods used to estimate coronary flow reserve in patients with coronary atherosclerosis. The physiological bases for determining fractional flow reserve are presented. Clinical trials investigating the use of fractional flow reserve in patients with coronary heart disease are analyzed.

  14. Reduced blood flow to contracting skeletal muscle in ageing humans

    DEFF Research Database (Denmark)

    Nyberg, Michael Permin; Hellsten, Ylva

    2016-01-01

    The ability to sustain a given absolute submaximal workload declines with advancing age likely due to a lower level of blood flow and O2 delivery to the exercising muscles. Given that physical inactivity mimics many of the physiological changes associated with ageing, separating the physiological...... consequences of ageing and physical inactivity can be challenging; yet, observations from cross-sectional and longitudinal studies on the effects of physical activity have provided some insight. Physical activity has the potential to offset the age-related decline in blood flow to contracting skeletal muscle...... the O2 demand of the active skeletal muscle of aged individuals during conditions where systemic blood flow is not limited by cardiac output seems to a large extent to be related to the level of physical activity. This article is protected by copyright. All rights reserved....

  15. Fractional flow reserve derived from coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Eftekhari, Ashkan; Min, James; Achenbach, Stephan

    2016-01-01

    AIMS: Fractional flow reserve (FFR) derived from coronary computed tomography (FFRCT) has high diagnostic performance in stable coronary artery disease (CAD). The diagnostic performance of FFRCT in patients with hypertension (HTN) and diabetes (DM), who are at risk of microvascular impairment, is...

  16. Quantitative Cerebral Blood Flow Measurements Using MRI

    OpenAIRE

    Muir, Eric R; Watts, Lora Talley; Tiwari, Yash Vardhan; Bresnen, Andrew; Timothy Q Duong

    2014-01-01

    Magnetic resonance imaging utilized as a quantitative and noninvasive method to image cerebral blood flow. The two most common techniques used to detect cerebral blood flow are dynamic susceptibility contrast (DSC) perfusion MRI and arterial spin labeling perfusion MRI. Herein we describe the use of these two techniques to measure cerebral blood flow in rodents, including methods, analysis, and important considerations when utilizing these techniques.

  17. Regional cerebral blood flow in schizophrenia

    Energy Technology Data Exchange (ETDEWEB)

    Mathew, R.J.; Duncan, G.C.; Weinman, M.L.; Barr, D.L.

    1982-10-01

    Regional cerebral blood flow (rCBF) was measured via xenon133 inhalation technique in 23 patients with schizophrenia and 18 age- and sex-matched controls. The mean blood flow to both hemispheres was found to be lower for the patients. The patients and their controls did not differ on interhemispheric differences in blood flow. There were no differences in rCBF between medicated and unmedicated, subchronic and chronic, and paranoid and nonparanoid patients. Hallucinations were associated with reduced blood flow to several postcentral regions.

  18. Inspiratory flow reserve in boys with Duchenne muscular dystrophy.

    Science.gov (United States)

    De Bruin, P F; Ueki, J; Bush, A; Y Manzur, A; Watson, A; Pride, N B

    2001-06-01

    Patients with advanced muscular dystrophy frequently develop ventilatory failure. Currently respiratory impairment usually is assessed by measuring vital capacity and the mouth pressure generated during a maximal inspiratory maneuver (PI,max), neither of which directly measures ventilatory capacity. We assessed inspiratory flow reserve in 26 boys [mean (SD) age 12.8 (3.8) years] with Duchenne muscular dystrophy (DMD) without ventilatory failure and in 28 normal boys [mean (SD) age 12.6 (1.9) years] by analyzing the ratio between the largest inspiratory flow during tidal breathing (V'I,max(t)) and during a forced vital capacity maneuver (V'I,max(FVC), (V'I,max(t)/V'I,maxFVC). We have compared this ratio with the forced vital capacity FVC and PI,max measured at functional residual capacity. Mean PI,max was -90(30)cmH2O, average 112% (range 57-179%) of predicted values in control boys and -31(11)cmH2O, average 40% predicted values in DMD boys (control vs DMD, P ratio was higher in DMD 0.22 (0.08) than in controls 0.12 (0.03) (P reserve in DMD. Inspiratory flow reserve was within the normal range in 8 of 19 DMD patients with PI,max less than 50% of predicted values. We conclude that measurement of inspiratory flow reserve (V'I,max(t)/V'I,maxFVC ratio) provides a simple and direct assessment of dynamic inspiratory muscle function which is not replicated by static measurement of PI,max or vital capacity and might be useful in assessment of respiratory impairment in boys with Duchenne muscular dystrophy. Follow-up studies are required to establish whether measures of inspiratory flow reserve are of clinical value in predicting subsequent ventilatory failure.

  19. Significant regional heterogeneity of coronary flow reserve in paediatric hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, E.; Kudoh, T.; Kubo, S.; Konishi, J. [Kyoto Univ. (Japan). School of Medicine; Yoshibayashi, M.; Yonemura, T. [Dept. of Pediatrics, Kyoto Univ. Graduate School of Medicine, Kyoto (Japan); Motooka, M.; Nohara, R.; Matsumori, A.; Sasayama, S. [Third Div., Dept. of Internal Medicine, Kyoto Univ. Graduate School of Medicine, Kyoto (Japan); Matsuda, T. [Dept. of Medical Informatics, Kyoto Univ. Graduate School of Medicine, Kyoto (Japan); Tamaki, N. [Dept. of Nuclear Medicine, Hokkaido Univ. School of Medicine, Sapporo (Japan)

    2000-09-01

    Previous studies have indicated that cardiac events in young patients with hypertrophic cardiomyopathy (HCM) are related to ischaemia rather than to arrhythmia. We measured coronary flow reserve in paediatric HCM and compared the values with those in adult HCM. We studied 12 patients with HCM including six paediatric (<20 years old; mean 13 years) and six adult patients (>20 years old: mean 62 years), and six healthy young adults (mean 29 years) as controls. Every patient underwent magnetic resonance imaging (MRI) for anatomical assessment. Myocardial blood flow at rest and after dipyridamole infusion was measured with dynamic nitrogen-13 ammonia positron emission tomography (PET). Partial volume effect was corrected for using the anatomical data obtained with MRI. In adult patients with HCM, coronary flow reserve in the hypertrophied septal region was not significantly different from that in the non-hypertrophied lateral wall (1.38{+-}0.29 vs 1.77{+-}0.39, respectively). In the paediatric patients, coronary flow reserve in the hypertrophied septal region was significantly lower than in the non-hypertrophied lateral wall (0.84{+-}0.33 vs 2.74{+-}0.90, respectively, P<0.01). In addition, coronary flow reserve in adult patients was lower than in control subjects both in the septal wall (1.38{+-}0.29 vs 2.94{+-}0.35, respectively, P<0.0001) and in the lateral wall (1.77{+-}0.39 vs 2.85{+-}0.69, respectively, P<0.05). In contrast, coronary flow reserve in paediatric patients was not significantly different from that in control subjects in the lateral wall (2.74{+-}0.90 vs 2.85{+-}0.69, respectively), while absolute reduction of myocardial blood flow was noted after pharmacological vasodilatation in the hypertrophied septal region. In conclusion, significant regional differences of coronary flow reserve were present in the paediatric patients with HCM. These results suggest that paediatric patients with HCM intrinsically have the potential to experience significant

  20. Pancreatic islet blood flow and its measurement.

    Science.gov (United States)

    Jansson, Leif; Barbu, Andreea; Bodin, Birgitta; Drott, Carl Johan; Espes, Daniel; Gao, Xiang; Grapensparr, Liza; Källskog, Örjan; Lau, Joey; Liljebäck, Hanna; Palm, Fredrik; Quach, My; Sandberg, Monica; Strömberg, Victoria; Ullsten, Sara; Carlsson, Per-Ola

    2016-05-01

    Pancreatic islets are richly vascularized, and islet blood vessels are uniquely adapted to maintain and support the internal milieu of the islets favoring normal endocrine function. Islet blood flow is normally very high compared with that to the exocrine pancreas and is autonomously regulated through complex interactions between the nervous system, metabolites from insulin secreting β-cells, endothelium-derived mediators, and hormones. The islet blood flow is normally coupled to the needs for insulin release and is usually disturbed during glucose intolerance and overt diabetes. The present review provides a brief background on islet vascular function and especially focuses on available techniques to measure islet blood perfusion. The gold standard for islet blood flow measurements in experimental animals is the microsphere technique, and its advantages and disadvantages will be discussed. In humans there are still no methods to measure islet blood flow selectively, but new developments in radiological techniques hold great hopes for the future.

  1. Bone blood flow and metabolism in humans

    DEFF Research Database (Denmark)

    Heinonen, Ilkka; Kemppainen, Jukka; Kaskinoro, Kimmo;

    2012-01-01

    Human bone blood flow and metabolism during physical exercise remains poorly characterised. In the present study we measured femoral bone blood flow and glucose uptake in young healthy subjects by positron emission tomography in three separate protocols. In six women, blood flow was measured...... in femoral bone at rest and during one leg intermittent isometric exercise with increasing exercise intensities. In nine men, blood flow in femur was determined at rest and during dynamic one leg exercise, and two other physiological perturbations: moderate systemic hypoxia (14 O(2) ) at rest and during...... exercise, and during intra-femoral infusion of high-dose adenosine. Bone glucose uptake was measured at rest and during dynamic one leg exercise in five men. The results indicate that isometric exercise increased femoral bone blood flow from rest (1.8 ± 0.6 ml/100g/min) to low intensity exercise (4.1 ± 1...

  2. The Physics of Coronary Blood Flow

    CERN Document Server

    Zamir, M

    2005-01-01

    Coronary blood flow is blood flow to the heart for its own metabolic needs. In the most common form of heart disease there is a disruption in this flow because of obstructive disease in the vessels that carry the flow. The subject of coronary blood flow is therefore associated mostly with the pathophysiology of this disease, rarely with dynamics or physics. Yet, the system responsible for coronary blood flow, namely the "coronary circulation," is a highly sophisticated dynamical system in which the dynamics and physics of the flow are as important as the integrity of the conducting vessels. While an obstruction in the conducting vessels is a fairly obvious and clearly visible cause of disruption in coronary blood flow, any discord in the complex dynamics of the system can cause an equally grave, though less conspicuous, disruption in the flow. This book is devoted specifically to the dynamics and physics of coronary blood flow. While relevance to the clinical and pathophysiological issues is clearly maintaine...

  3. Mechanics of blood flow in the microcirculation.

    Science.gov (United States)

    Secomb, T W

    1995-01-01

    The microcirculation in most tissues consists of an intricate network of very narrow tubes. In analyses of blood flow through the microcirculation, inertial effects can be neglected, but continuum models for blood cannot be assumed, since blood is a concentrated suspension of cells with dimensions comparable to vessel diameters. These cells strongly influence blood flow. About 45% of blood volume consists of red blood cells, whose key mechanical properties are known. A red cell has a fluid interior, surrounded by a flexible membrane, which strongly resists area changes, but bends and shears easily. White blood cells are comparable in size but much less numerous. They are less flexible than red cells and capable of active locomotion. Other suspended elements are much smaller than red cells: This review focuses on the mechanics of red cell motion in the microcirculation. Experimental and theoretical studies of blood flow in uniform tubes, bifurcations and networks are discussed. Comparisons between predicted and observed flows in networks imply that resistance to blood flow in living microvessels is higher than that in uniform tubes with corresponding diameters. Living microvessels have non-uniform geometries, and red cells must deform continually to traverse them. Theoretical results are presented implying that these transient deformations contribute to increased flow resistance in the microcirculation.

  4. Determination of fractional flow reserve (FFR) based on scaling laws: a simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Jerry T; Molloi, Sabee [Department of Radiological Sciences, University of California, Irvine-92697, CA (United States)], E-mail: symolloi@uci.edu

    2008-07-21

    Fractional flow reserve (FFR) provides an objective physiological evaluation of stenosis severity. A technique that can measure FFR using only angiographic images would be a valuable tool in the cardiac catheterization laboratory. To perform this, the diseased blood flow can be measured with a first pass distribution analysis and the theoretical normal blood flow can be estimated from the total coronary arterial volume based on scaling laws. A computer simulation of the coronary arterial network was used to gain a better understanding of how hemodynamic conditions and coronary artery disease can affect blood flow, arterial volume and FFR estimation. Changes in coronary arterial flow and volume due to coronary stenosis, aortic pressure and venous pressure were examined to evaluate the potential use of flow and volume for FFR determination. This study showed that FFR can be estimated using arterial volume and a scaling coefficient corrected for aortic pressure. However, variations in venous pressure were found to introduce some error in FFR estimation. A relative form of FFR was introduced and was found to cancel out the influence of pressure on coronary flow, arterial volume and FFR estimation. The use of coronary flow and arterial volume for FFR determination appears promising.

  5. Blood flow autoregulation in pedicled flaps

    DEFF Research Database (Denmark)

    Bonde, Christian T; Holstein-Rathlou, Niels-Henrik; Elberg, Jens J

    2009-01-01

    INTRODUCTION: Clinical work on the blood perfusion in skin and muscle flaps has suggested that some degree of blood flow autoregulation exists in such flaps. An autoregulatory mechanism would enable the flap to protect itself from changes in the perfusion pressure. The purpose of the present study...... was to evaluate if, and to what extent, a tissue flap could compensate a reduction in blood flow due to an acute constriction of the feed artery. Further, we wanted to examine the possible role of smooth muscle L-type calcium channels in the autoregulatory mechanism by pharmacological intervention with the L......-type calcium channel blocker nimodipine and the vasodilator papaverine. MATERIAL AND METHODS: Pedicled flaps were raised in pigs. Flow in the pedicle was reduced by constriction of the feed artery (n=34). A transit time flow probe measured the effect on blood flow continuously. Following this, three different...

  6. Carbon dioxide and liver blood flow.

    Science.gov (United States)

    Dutton, R; Levitzky, M; Berkman, R

    1976-01-01

    This study was designed to determine blood flow to the liver during hypercapnia and combined hypercapnia-hypoxia with the portal vein and hepatic artery intact except for placement of an electromagnetic flow probe around these vessels. Twenty mongrel dogs weighing 30-45 kg were anesthetized with pentobarbital and flow probes and occluders were surgically implanted. Ten of these dogs were subjected to hypercapnia alone. During inspiration of 6% CO2 in room air, portal vein flow increased from 588 +/- 73 ml/min to 731 +/- 113 ml/min (p less than .05), while hepatic artery flow did not change significantly from its control mean of 221 +/- 38 ml/min. In the remaining dogs, inhalation of 6% O2 resulted in a reduction of portal blood flow within 30 min from 527 +/- 55 ml/min to 381 +/- 41 ml/min (p less than .01). Again, mean hepatic artery flow did not increase significantly above its control of 273 +/- 43 ml/min. Subsequent inhalation of 6% CO2 plus 6% O2 (combined hypercapniahypoxia) for 30 min in these same animals resulted in a significant increase of portal vein blood flow from 514 +/- 46 ml/min to 716 +/- 116 ml/min (p less than .05). Thus, hypercapnia alone increases total liver blood flow, primarily by an increase in portal vein flow. Hypoxia results in a decrease in portal vein flow. The superimposition of hypercapnia on hypoxia restores blood flow to a level close to that found with hypercapnia alone. Hypercapnia in the range of 63 +/- 4 mmHg PCO2 overwhelms the tendency toward a reduction of portal vein blood flow induced by an arterial PO2 of 42 +/- 5 mmHg in the presence of mild hypocapnia (PCO2 : 30.2 +/- 1 mmHg).

  7. Fractional Flow Reserve-Guided Multivessel Angioplasty in Myocardial Infarction.

    Science.gov (United States)

    Smits, Pieter C; Abdel-Wahab, Mohamed; Neumann, Franz-Josef; Boxma-de Klerk, Bianca M; Lunde, Ketil; Schotborgh, Carl E; Piroth, Zsolt; Horak, David; Wlodarczak, Adrian; Ong, Paul J; Hambrecht, Rainer; Angerås, Oskar; Richardt, Gert; Omerovic, Elmir

    2017-03-30

    Background In patients with ST-segment elevation myocardial infarction (STEMI), the use of percutaneous coronary intervention (PCI) to restore blood flow in an infarct-related coronary artery improves outcomes. The use of PCI in non-infarct-related coronary arteries remains controversial. Methods We randomly assigned 885 patients with STEMI and multivessel disease who had undergone primary PCI of an infarct-related coronary artery in a 1:2 ratio to undergo complete revascularization of non-infarct-related coronary arteries guided by fractional flow reserve (FFR) (295 patients) or to undergo no revascularization of non-infarct-related coronary arteries (590 patients). The FFR procedure was performed in both groups, but in the latter group, both the patients and their cardiologist were unaware of the findings on FFR. The primary end point was a composite of death from any cause, nonfatal myocardial infarction, revascularization, and cerebrovascular events at 12 months. Clinically indicated elective revascularizations performed within 45 days after primary PCI were not counted as events in the group receiving PCI for an infarct-related coronary artery only. Results The primary outcome occurred in 23 patients in the complete-revascularization group and in 121 patients in the infarct-artery-only group that did not receive complete revascularization, a finding that translates to 8 and 21 events per 100 patients, respectively (hazard ratio, 0.35; 95% confidence interval [CI], 0.22 to 0.55; Pratio, 0.80; 95% CI, 0.25 to 2.56), myocardial infarction in 7 and 28 patients, respectively (2.4% vs. 4.7%) (hazard ratio, 0.50; 95% CI, 0.22 to 1.13), revascularization in 18 and 103 patients (6.1% vs. 17.5%) (hazard ratio, 0.32; 95% CI, 0.20 to 0.54), and cerebrovascular events in 0 and 4 patients (0 vs. 0.7%). An FFR-related serious adverse event occurred in 2 patients (both in the group receiving infarct-related treatment only). Conclusions In patients with STEMI and multivessel

  8. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, Donald J; Sosnovtseva, Olga; Pavlov, Alexey N;

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation...... of the myogenic oscillation by TGF. Analysis by wavelet transforms of single-nephron blood flow confirms that both amplitude and frequency of the myogenic oscillation are modulated by TGF. We developed a double-wavelet transform technique to estimate modulation frequency. Median value of the ratio of modulation...... TGF cycle to the next. We used a blood pressure signal recorded by telemetry from a conscious rat as the input to the model. Blood pressure fluctuations induced variability in the modulation records similar to those found in the nephron blood flow results. Frequency and amplitude modulation can...

  9. Regulation of blood flow by prostaglandins

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher; Langberg, H; Risum, N;

    2004-01-01

    adaptation of connective tissues e.g. tendon. This review covers the role of PG for mediating tissue blood flow at rest and during increases in metabolic demand such as exercise and reactive hyperaemia. There is strong evidence that PGs contribute to elevate blood flow at rest and during reactive hyperaemia...... in a variety of tissues. Their role for regulating the large increases in muscle blood flow during exercise is less clear which may be explained by redundant mechanisms. Several interactions are known to exist between specific vasodilator substances, and therefore PGs can act in synergy with other substances...... and contribute to functional hyperaemia. Furthermore, there is evidence for differential, tissue-specific influences of PGs where their influence on blood flow during exercise may be profound....

  10. Blood flow and permeability in microvessels

    Science.gov (United States)

    Sugihara-Seki, Masako; Fu, Bingmei M.

    2005-07-01

    The mechanics of blood flow in microvessels and microvessel permeability are reviewed. In the first part, characteristics of blood flow in vivo and in vitro are described from a fluid-mechanical point of view, and mathematical models for blood flow in microvessels are presented. Possible causes of the increased flow resistance obtained in vivo compared to in vitro are examined, including the effects of irregularities of vessel lumen, the presence of endothelial surface glycocalyx and white blood cells. In the second part, the ultrastructural pathways and mechanisms whereby endothelial cells and the clefts between the cells modulate microvessel permeability to water and solutes are introduced. Previous and current models for microvessel permeability to water and solutes are reviewed. These models examine the role of structural components of interendothelial cleft, such as junction strands and surface glycocalyx, in the determination of water and solute transport across the microvessel walls. Transport models in the tissue space surrounding the microvessel are also described.

  11. Significance of assess the iron reserves of severe renal anemia patients before and after blood transfusion

    Institute of Scientific and Technical Information of China (English)

    Gui-Fen Zhang

    2015-01-01

    Objective:To study the significance of evaluating hemoglobin and iron reserves in the severe renal anemia patient before and after blood transfusion, to guide clinical treatment.Methods:Simple randomly selected 120 patients in phase 5 of chronic renal failure from the department of nephrology, who are regular dialysis with severe renal anemia, according to the situation of iron reserves before blood transfusion, patients will be divided into its reserves of iron deficiency and iron overload group and normal group, and the three groups were divided into 1 U and 2 U group. Comparing the change of different unit quantity of hemoglobin, serum iron, iron, protein and total iron binding force before and after blood transfusion and variation is compared between groups.Results: Three groups of patients with 1U blood transfusion ,Hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation are higher before a blood transfusion,The differences were statistically significant; before and after blood transfusion hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation change in 1 U group normal iron reserves compared with Insufficient iron reserves 1 U group has no statistically significant difference, iron overload 1 U group before and after blood transfusion hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation change significantly greater than Insufficient iron reserves 1 U group and 1U with normal iron reserves group, the differences were statistically significant; Three groups of patients blood transfusion after 2 U, hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation were higher before a blood transfusion, differences were statistically significant; iron overload 2 U group before and after blood transfusion hemoglobin, serum iron and ferritin, total iron binding force, transferrin saturation change significantly greater than Insufficient iron reserves 2

  12. 21 CFR 870.2120 - Extravascular blood flow probe.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Extravascular blood flow probe. 870.2120 Section... blood flow probe. (a) Identification. An extravascular blood flow probe is an extravascular ultrasonic or electromagnetic probe used in conjunction with a blood flowmeter to measure blood flow in...

  13. Cerebral blood flow response to functional activation

    DEFF Research Database (Denmark)

    Paulson, Olaf B; Hasselbalch, Steen G; Rostrup, Egill

    2010-01-01

    Cerebral blood flow (CBF) and cerebral metabolic rate are normally coupled, that is an increase in metabolic demand will lead to an increase in flow. However, during functional activation, CBF and glucose metabolism remain coupled as they increase in proportion, whereas oxygen metabolism only...

  14. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Tonino, Pim A L; De Bruyne, Bernard; Pijls, Nico H J

    2009-01-01

    BACKGROUND: In patients with multivessel coronary artery disease who are undergoing percutaneous coronary intervention (PCI), coronary angiography is the standard method for guiding the placement of the stent. It is unclear whether routine measurement of fractional flow reserve (FFR; the ratio......-eluting stents guided by angiography alone or guided by FFR measurements in addition to angiography. Before randomization, lesions requiring PCI were identified on the basis of their angiographic appearance. Patients assigned to angiography-guided PCI underwent stenting of all indicated lesions, whereas those...

  15. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H;

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  16. Coronary flow reserve measurement in the coronary sinus in pre and post CABG status

    Directory of Open Access Journals (Sweden)

    M Hajaghaei

    2007-11-01

    Full Text Available Background: Coronary flow reserve (CFR is defined as a maximal(hyperemic to resting ratio of coronary blood flow. It is a physiologicparameter of coronary circulation and depends on the patency of the epicardialcoronary arteries and integrity of the microvascular circulation.CFR measurement has many clinical applications including functional assessmentof intermediate stenosis, detection of critical stenosis monitoring of coronaryflow in the post angioplasty period, assessment of post infarct blood flow andassessment of coronary graft patency. The aim of this study was to measure CFRin the coronary sinus through the transthoracic echocardiographic approach, inpatients who were candidate for coronary artery bypass graft surgery (CABGbefore and one month after operation.Patients and Methods: The present study included 19 patients (meanage=56±9.1 including 15 males and 4 females, admitted for CABG. All patientshad a sinus rhythm, normal wall thickness, normal RV systolic pressure, andtricuspid valvular regurgitation equal or less than grade 2. The antegrade phaseof coronary flow in the coronary sinus moving into the right atrium was analyzedin two phases (systolic and diastolic. Each wave was determined considering thepeak velocity and velocity time integral (VTI. The volumetric blood flow in thecoronary sinus calculated at the baseline and then in hyperemic phase was usedfor determination of CFR both before and after CABG.Results: There was a significant increase in the diameter of the coronarysinus after CABG (9.4±1.2mm compared with that of before CABG values (8.6±1.05mm. Also there was a trend of increasing the diameter in the hyperemicphase before and after CABG. The absolute increase in mean coronary sinusdiameter was 0.5 mm before and 1.5 mm after CABG. Coronary flow reserve (CFRwas significantly higher after surgery, despite a significant increase insystolic velocity ratio (hyperemic/baseline after CABG. This is also true forsystolic

  17. An implantable blood pressure and flow transmitter.

    Science.gov (United States)

    Rader, R. D.; Meehan, J. P.; Henriksen, J. K. C.

    1973-01-01

    A miniature totally implantable FM/FM telemetry system has been developed to simultaneously measure blood pressure and blood flow, thus providing an appreciation of the hemodynamics of the circulation to the entire body or to a particular organ. Developed for work with animal subjects, the telemetry system's transmission time is controlled by an RF signal that permits an operating life of several months. Pressure is detected by a miniature intravascular transducer and flow is detected by an extravascular interferometric ultrasonic technique. Both pressure and flow are calibrated prior to implanting. The pressure calibration can be checked after the implanting by cannulation; flow calibration can be verified only at the end of the experiment by determining the voltage output from the implanted sensing system as a function of several measured flow rates. The utility of this device has been established by its use in investigating canine renal circulation during exercise, emotional encounters, administration of drugs, and application of accelerative forces.

  18. BLOOD FLOW AND MACROMOLECULAR TRANSPORT IN CURVED BLOOD VESSELS

    Institute of Scientific and Technical Information of China (English)

    WEI Lan; WEN Gong-bi; TAN Wen-chang

    2006-01-01

    A numerical analysis of the steady/pulsatile flow and macromolecular (such as LDL and Albumin) transport in curved blood vessels was carried out. The computational results predict that the vortex of the secondary flow is time-dependent in the aortic arch.The concentration of macromolecule concentrates at the region of sharp curve, and the wall concentration at the outer part is higher than that at the inner part. Atherosclerosis and thrombosis are prone to develop in such regions with sharp flow.

  19. The deep hydrogeologic flow system underlying the Oak Ridge Reservation

    Energy Technology Data Exchange (ETDEWEB)

    Nativ, R. [Hebrew Univ., Jerusalem (IL); Hunley, A.E. [Oak Ridge National Lab., TN (United States)

    1993-07-01

    The deep hydrogeologic system underlying the Oak Ridge Reservation contains some areas contaminated with radionuclides, heavy metals, nitrates, and organic compounds. The groundwater at that depth is saline and has previously been considered stagnant. On the basis of existing and newly collected data, the nature of flow of the saline groundwater and its potential discharge into shallow, freshwater systems was assessed. Data used for this purpose included (1) spatial and temporal pressures and hydraulic heads measured in the deep system, (2) hydraulic parameters of the formations in question, (3) spatial temperature variations, and (4) spatial and temporal chemical and isotopic composition of the saline groundwater. In addition, chemical analyses of brine in adjacent areas in Tennessee, Kentucky, Ohio, Pennsylvania, and West Virginia were compared with the deep water underlying the reservation to help assess the origin of the brine. Preliminary conclusions suggest that the saline water contained at depth is old but not isolated (in terms of recharge and discharge) from the overlying active and freshwater-bearing units. The confined water (along with dissolved solutes) moves along open fractures (or man-made shortcuts) at relatively high velocity into adjacent, more permeable units. Groundwater volumes involved in this flow probably are small.

  20. A Methodology for Modeling the Flow of Military Personnel Across Air Force Active and Reserve Components

    Science.gov (United States)

    2016-01-01

    for pilots will depend on the • number of active component pilots who separate • fraction of separating pilots who affiliate with the reserve ...when tracking economic output over a period of time. GDP data were collected from the Federal Reserve Economic Data (FRED), Federal Reserve Bank of St...C O R P O R A T I O N Research Report A Methodology for Modeling the Flow of Military Personnel Across Air Force Active and Reserve Components

  1. Cerebral blood flow in the neonate.

    Science.gov (United States)

    Vutskits, Laszlo

    2014-01-01

    Ensuring adequate oxygenation of the developing brain is the cornerstone of neonatal critical care. Despite decades of clinical research dedicated to this issue of paramount importance, our knowledge and understanding regarding the physiology and pathophysiology of neonatal cerebral blood flow are still rudimentary. This review primarily focuses on currently available human clinical and experimental data on cerebral blood flow and autoregulation in the preterm and term infant. Limitations of systemic blood pressure values as surrogates for monitoring adequate cerebral oxygen delivery are discussed. Particular emphasis is placed on the high interindividual variability in cerebral blood flow values, vasoreactivity, and autoregulatory thresholds making the applications of normative values highly questionable. Technical and ethical difficulties to conduct such trials leave us with a near complete lack of knowledge on how pharmacological and surgical interventions impact on cerebral autoregulation. The ensemble of these works argues for the necessity of highly individualized care by taking advantage of continuous bedside monitoring of cerebral circulation. They also point to the urgent need for further studies addressing the exciting but difficult issue of cerebral blood flow autoregulation in the neonate.

  2. Intensive blood pressure control affects cerebral blood flow in type 2 diabetes mellitus patients

    DEFF Research Database (Denmark)

    Kim, Yu-Sok; Davis, Shyrin C A T; Truijen, Jasper;

    2011-01-01

    Type 2 diabetes mellitus is associated with microvascular complications, hypertension, and impaired dynamic cerebral autoregulation. Intensive blood pressure (BP) control in hypertensive type 2 diabetic patients reduces their risk of stroke but may affect cerebral perfusion. Systemic hemodynamic...... variables and transcranial Doppler-determined cerebral blood flow velocity (CBFV), cerebral CO2 responsiveness, and cognitive function were determined after 3 and 6 months of intensive BP control in 17 type 2 diabetic patients with microvascular complications (T2DM+), in 18 diabetic patients without (T2DM......-) microvascular complications, and in 16 nondiabetic hypertensive patients. Cerebrovascular reserve capacity was lower in T2DM+ versus T2DM- and nondiabetic hypertensive patients (4.6±1.1 versus 6.0±1.6 [P

  3. Blood flow characteristics in the aortic arch

    Science.gov (United States)

    Prahl Wittberg, Lisa; van Wyk, Stevin; Mihaiescu, Mihai; Fuchs, Laszlo; Gutmark, Ephraim; Backeljauw, Philippe; Gutmark-Little, Iris

    2012-11-01

    The purpose with this study is to investigate the flow characteristics of blood in the aortic arch. Cardiovascular diseases are associated with specific locations in the arterial tree. Considering atherogenesis, it is claimed that the Wall Shear Stress (WSS) along with its temporal and spatial gradients play an important role in the development of the disease. The WSS is determined by the local flow characteristics, that in turn depends on the geometry as well as the rheological properties of blood. In this numerical work, the time dependent fluid flow during the entire cardiac cycle is fully resolved. The Quemada model is applied to account for the non-Newtonian properties of blood, an empirical model valid for different Red Blood Cell loading. Data obtained through Cardiac Magnetic Resonance Imaging have been used in order to reconstruct geometries of the the aortic arch. Here, three different geometries are studied out of which two display malformations that can be found in patients having the genetic disorder Turner's syndrome. The simulations show a highly complex flow with regions of secondary flow that is enhanced for the diseased aortas. The financial support from the Swedish Research Council (VR) and the Sweden-America Foundation is gratefully acknowledged.

  4. Transcutaneous measurement of volume blood flow

    Science.gov (United States)

    Daigle, R. E.; Mcleod, F. D.; Miller, C. W.; Histand, M. B.; Wells, M. K.

    1974-01-01

    Blood flow velocity measurements, using Doppler velocimeter, are described. The ability to measure blood velocity using ultrasound is derived from the Doppler effect; the change in frequency which occurs when sound is reflected or transmitted from a moving target. When ultrasound of the appropriate frequency is transmitted through a moving blood stream, the blood cells act as point scatterers of ultrasonic energy. If this scattered ultrasonic energy is detected, it is found to be shifted in frequency according to the velocity of the blood cells, nu, the frequency of the incident sound, f sub o, the speed of sound in the medium, c, and the angle between the sound beam and the velocity vector, o. The relation describing this effect is known as the Doppler equation. Delta f = 2 f sub o x nu x cos alpha/c. The theoretical and experimental methods are evaluated.

  5. Effect of intravenous infusion of iodinated contrast media on the coronary blood flow in dogs

    OpenAIRE

    Abd, Thura T; Asim I. Shafique; Hayder S. Yasir; Jung-Hee Seo; George, Richard T.; Rajat Mittal; Lardo, Albert C.

    2016-01-01

    Background: Coronary computed tomography angiography (CCTA) is obtained using peripheral intravenous iodinated contrast agents (ICA) injection. There is continuing attempts to derive coronary physiological information like coronary blood flow (CBF) and/or fractional flow reserve from CCTA images. However, no data is available regarding the effect of peripheral intravenous injection of ICA on CBF. Methods: A series of 4 experiments was performed using healthy mongrel dogs. All dogs underwen...

  6. Blood flow dynamics in the snake spectacle.

    Science.gov (United States)

    van Doorn, Kevin; Sivak, Jacob G

    2013-11-15

    The eyes of snakes are shielded beneath a layer of transparent integument referred to as the 'reptilian spectacle'. Well adapted to vision by virtue of its optical transparency, it nevertheless retains one characteristic of the integument that would otherwise prove detrimental to vision: its vascularity. Given the potential consequence of spectacle blood vessels on visual clarity, one might expect adaptations to have evolved that mitigate their negative impact. Earlier research demonstrated an adaptation to their spatial layout in only one species to reduce the vessels' density in the region serving the foveal and binocular visual fields. Here, we present a study of spectacle blood flow dynamics and provide evidence of a mechanism to mitigate the spectacle blood vessels' deleterious effect on vision by regulation of blood flow through them. It was found that when snakes are at rest and undisturbed, spectacle vessels undergo cycles of dilation and constriction, such that the majority of the time the vessels are fully constricted, effectively removing them from the visual field. When snakes are presented with a visual threat, spectacle vessels constrict and remain constricted for longer periods than occur during the resting cycles, thus guaranteeing the best possible visual capabilities in times of need. Finally, during the snakes' renewal phase when they are generating a new stratum corneum, the resting cycle is abolished, spectacle vessels remain dilated and blood flow remains strong and continuous. The significance of these findings in terms of the visual capabilities and physiology of snakes is discussed.

  7. Regional cerebral blood flow in aphasia

    DEFF Research Database (Denmark)

    Soh, K; Larsen, B; Skinhøj, E

    1978-01-01

    Regional cerebral blood flow (rCBF) was studied in 13 aphasic patients with left hemisphere lesions, using the intracarotid xenon 133 injection method and a 254-detector gamma camera system. The rCBF was measured during rest and during various function tests, including a simple speech test...

  8. Effects of aortic irregularities on blood flow.

    Science.gov (United States)

    Prahl Wittberg, Lisa; van Wyk, Stevin; Fuchs, Laszlo; Gutmark, Ephraim; Backeljauw, Philippe; Gutmark-Little, Iris

    2016-04-01

    Anatomic aortic anomalies are seen in many medical conditions and are known to cause disturbances in blood flow. Turner syndrome (TS) is a genetic disorder occurring only in females where cardiovascular anomalies, particularly of the aorta, are frequently encountered. In this study, numerical simulations are applied to investigate the flow characteristics in four TS patient- related aortic arches (a normal geometry, dilatation, coarctation and elongation of the transverse aorta). The Quemada viscosity model was applied to account for the non-Newtonian behavior of blood. The blood is treated as a mixture consisting of water and red blood cells (RBC) where the RBCs are modeled as a convected scalar. The results show clear geometry effects where the flow structures and RBC distribution are significantly different between the aortas. Transitional flow is observed as a jet is formed due to a constriction in the descending aorta for the coarctation case. RBC dilution is found to vary between the aortas, influencing the WSS. Moreover, the local variations in RBC volume fraction may induce large viscosity variations, stressing the importance of accounting for the non-Newtonian effects.

  9. Ergot alkaloids decrease rumen epithelial blood flow

    Science.gov (United States)

    Two experiments were conducted to determine if ergot alkaloids affect blood flow to the absorptive surface of the rumen of steers. Steers (n=8 total) were pair-fed alfalfa cubes at 1.5× NEM and received ground endophyte-infected tall fescue seed (E+) or endophyte-free tall fescue seed (E-) via rumen...

  10. Cerebral blood flow in acute mountain sickness

    DEFF Research Database (Denmark)

    Jensen, J B; Wright, Anne; Lassen, N A

    1990-01-01

    Changes in cerebral blood flow (CBF) were measured using the radioactive xenon technique and were related to the development of acute mountain sickness (AMS). In 12 subjects, ascending from 150 to 3,475 m, CBF was 24% increased at 24 h [45.1 to 55.9 initial slope index (ISI) units] and 4% increased...

  11. Frequency encoding in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, D.J.; Sosnovtseva, Olga; Pavlov, A.N.

    2005-01-01

    With a model of renal blood flow regulation, we examined consequences of tubuloglomerular feedback (TGF) coupling to the myogenic mechanism via voltage-gated Ca channels. The model reproduces the characteristic oscillations of the two mechanisms and predicts frequency and amplitude modulation...

  12. Image-based assessment of fractional flow reserve.

    Science.gov (United States)

    Tu, Shengxian; Bourantas, Christos V; Nørgaard, Bjarne L; Kassab, Ghassan S; Koo, Bon-Kwon; Reiber, Johan H C

    2015-01-01

    Pressure-derived fractional flow reserve (FFR) is an index of the haemodynamic significance of a coronary lesion. Numerous studies have provided robust evidence that FFR-guided percutaneous coronary intervention is associated with better clinical outcomes and reduces the need for repeat revascularisation. Although FFR is regarded as the gold standard for assessing lesion severity, it has limited clinical applications, mainly because it is a relatively expensive and time-consuming procedure. To overcome these limitations, several computational-based methodologies have been developed which enable estimation of the FFR in three-dimensional models derived from anatomic imaging data. Multislice computed tomographic coronary angiography and quantitative coronary angiography have been proposed for coronary reconstruction and computational evaluation of the FFR. In this review article, we describe the currently available methodologies for the computational estimation of FFR, present evidence derived from their clinical evaluations, stress their limitations, and discuss their potential value in clinical practice.

  13. Fractional flow reserve and instantaneous wave free ratio in 2015.

    Science.gov (United States)

    Kondareddy, S R; Singh, M; Stapleton, D; Rudzinski, W; Kaluski, E

    2015-06-01

    In the recent years it has become apparent that angiography-based assessment of coronary artery stenosis suffers from considerable inaccuracy and pitfalls. Besides interobserver variability in assessing stenosis severity, the correlation between angiographic severity and ischemia is suboptimal. Percutaneous coronary intervention (PCI) guided by the physiologic lesion assessment employing fractional flow reserve (FFR) is rendered superior to angiographic lesion assessment and proven to improve cardiovascular outcomes and reduce cost. In this manuscript we discuss the accepted and emerging clinical indications for FFR use. The correlation between FFR and symptoms, stress imaging and intravascular ultrasound are reviewed along with the inherent limitations and pitfalls of these diagnostic technologies. The data regarding the correlation between Instantaneous (vasodilator free) wave-free ratio (iFR) and conventional FFR is summarized.

  14. Evaluation of changes of intracranial blood flow after carotid artery stenting using digital subtraction angiography flow assessment

    Institute of Scientific and Technical Information of China (English)

    Hajime; Wada; Masato; Saito; Kyousuke; Kamada

    2015-01-01

    AIM: To evaluate the changes of intracranial blood flow after carotid artery stenting(CAS), using the flow assessment application "Flow-Insight", which was developed in our department.METHODS: Twenty patients treated by CAS participated in this study. We analyzed the change in concentration of the contrast media at the anterior-posterior and profile view image with the flow assessment application "Flow-Insight". And we compared the results with N-isopropyl-p-[123I] iodoamphetamine-single-photon emission computed tomography(IMP SPECT) performed before and after the treatment. RESULTS: From this study, 200% of the parameter "blood flow" change in the post/pre-treatment is suggested as the critical line of the hyperperfusion syndrome arise. Although the observed blood flow increase in the digital subtraction angiography system did not strongly correlate with the rate of increase of SPECT, the "Flow-Insight" reflected the rate of change of the vessels well. However, for patients with reduced reserve blood flow before CAS, a highly elevated site was in agreement with the site analysis results. CONCLUSION: We concluded that the cerebral angiography flow assessment application was able to more finely reveal hyperperfusion regions in the brain after CAS compared to SPECT.

  15. Ocular Blood Flow and Normal Tension Glaucoma

    Directory of Open Access Journals (Sweden)

    Ning Fan

    2015-01-01

    Full Text Available Normal tension glaucoma (NTG is known as a multifactorial optic neuropathy characterized by progressive retinal ganglion cell death and glaucomatous visual field loss, even though the intraocular pressure (IOP does not exceed the normal range. The pathophysiology of NTG remains largely undetermined. It is hypothesized that the abnormal ocular blood flow is involved in the pathogenesis of this disease. A number of evidences suggested that the vascular factors played a significant role in the development of NTG. In recent years, the new imaging techniques, fluorescein angiography, color Doppler imaging (CDI, magnetic resonance imaging (MRI, and laser speckle flowgraphy (LSFG, have been used to evaluate the ocular blood flow and blood vessels, and the impaired vascular autoregulation was found in patients with NTG. Previous studies showed that NTG was associated with a variety of systemic diseases, including migraine, Alzheimer’s disease, primary vascular dysregulation, and Flammer syndrome. The vascular factors were involved in these diseases. The mechanisms underlying the abnormal ocular blood flow in NTG are still not clear, but the risk factors for glaucomatous optic neuropathy likely included oxidative stress, vasospasm, and endothelial dysfunction.

  16. Dexmedetomidine decreases the oral mucosal blood flow.

    Science.gov (United States)

    Kawaai, Hiroyoshi; Yoshida, Kenji; Tanaka, Eri; Togami, Kohei; Tada, Hitoshi; Ganzberg, Steven; Yamazaki, Shinya

    2013-12-01

    There is an abundance of blood vessels in the oral cavity, and intraoperative bleeding can disrupt operations. There have been some interesting reports about constriction of vessels in the oral cavity, one of which reported that gingival blood flow in cats is controlled by sympathetic α-adrenergic fibres that are involved with vasoconstriction. Dexmedetomidine is a sedative and analgesic agent that acts through the α-2 adrenoceptor, and is expected to have a vasoconstrictive action in the oral cavity. We have focused on the relation between the effects of α-adrenoceptors by dexmedetomidine and vasoconstriction in oral tissues, and assessed the oral mucosal blood flow during sedation with dexmedetomidine. The subjects comprised 13 healthy male volunteers, sedated with dexmedetomidine in a loading dose of 6 μg/kg/h for 10 min and a continuous infusion of 0.7 μg/kg/h for 32 min. The mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), stroke volume (SV), systemic vascular resistance (SVR), and palatal mucosal blood flow (PMBF) were measured at 0, 5, 10, 12, 22, and 32 min after the start of the infusion. The HR, CO, and PBMF decreased significantly during the infusion even though there were no differences in the SV. The SVR increased significantly but the PMBF decreased significantly. In conclusion, PMBF was reduced by the mediating effect of dexmedetomidine on α-2 adrenoceptors.

  17. Red blood cell clusters in Poiseuille flow

    Science.gov (United States)

    Ghigliotti, Giovanni; Selmi, Hassib; Misbah, Chaouqi; Elasmi, Lassaad

    2011-11-01

    We present 2D numerical simulations of sets of vesicles (closed bags of a lipid bilayer membrane) in a parabolic flow, a setup that mimics red blood cells (RBCs) in the microvasculature. Vesicles, submitted to sole hydrodynamical interactions, are found to form aggregates (clusters) of finite size. The existence of a maximal cluster size is pointed out and characterized as a function of the flow intensity and the swelling ratio of the vesicles. Moreover bigger clusters move at lower velocity, a fact that may prove of physiological interest. These results quantify previous observations of the inhomogeneous distribution of RBCs in vivo (Gaehtgens et al., Blood Cells 6 - 1980). An interpretation of the phenomenon is put forward based on the presence of boli (vortices) between vesicles. Both the results and the explanation can be transposed to the three-dimensional case.

  18. Deterministic Aperiodic Sickle Cell Blood Flows

    Science.gov (United States)

    Atsaves, Louis; Harris, Wesley

    2013-11-01

    In this paper sickle cell blood flow in the capillaries is modeled as a hydrodynamical system. The hydrodynamical system consists of the axisymmetric unsteady, incompressible Navier-Stokes equations and a set of constitutive equations for oxygen transport. Blood cell deformation is not considered in this paper. The hydrodynamical system is reduced to a system of non-linear partial differential equations that are then transformed into a system of three autonomous non-linear ordinary differential equations and a set of algebraic equations. We examine the hydrodynamical system to discern stable/unstable, periodic/nonperiodic, reversible/irreversible properties of the system. The properties of the solutions are driven in large part by the coefficients of the governing system of equations. These coefficients depend on the physiological properties of the sickle cell blood. The chaotic nature of the onset of crisis in sickle cell patients is identified. Research Assistant.

  19. Computational Analysis of Human Blood Flow

    Science.gov (United States)

    Panta, Yogendra; Marie, Hazel; Harvey, Mark

    2009-11-01

    Fluid flow modeling with commercially available computational fluid dynamics (CFD) software is widely used to visualize and predict physical phenomena related to various biological systems. In this presentation, a typical human aorta model was analyzed assuming the blood flow as laminar with complaint cardiac muscle wall boundaries. FLUENT, a commercially available finite volume software, coupled with Solidworks, a modeling software, was employed for the preprocessing, simulation and postprocessing of all the models.The analysis mainly consists of a fluid-dynamics analysis including a calculation of the velocity field and pressure distribution in the blood and a mechanical analysis of the deformation of the tissue and artery in terms of wall shear stress. A number of other models e.g. T branches, angle shaped were previously analyzed and compared their results for consistency for similar boundary conditions. The velocities, pressures and wall shear stress distributions achieved in all models were as expected given the similar boundary conditions. The three dimensional time dependent analysis of blood flow accounting the effect of body forces with a complaint boundary was also performed.

  20. Association of arterial stiffness with coronary flow reserve in revascularized coronary artery disease patients

    Institute of Scientific and Technical Information of China (English)

    Vlassis Tritakis; Stavros Tzortzis; Ignatios Ikonomidis; Kleanthi Dima; Georgios Pavlidis; Paraskevi Trivilou; Ioannis Paraskevaidis; Giorgos Katsimaglis; John Parissis; John Lekakis

    2016-01-01

    AIM: To investigate the association of arterial wave reflection with coronary flow reserve(CFR) in coronary artery disease(CAD) patients after successful revascularization.METHODS: We assessed 70 patients with angiographically documented CAD who had undergone recent successful revascularization. We measured(1) reactive hyperemia index(RHI) using fingertip peripheral arterial tonometry(RH-PAT Endo-PAT);(2) carotid to femoral pulse wave velocity(PWVc-Complior);(3) augmentation index(AIx), the diastolic area(DAI%) and diastolic reflection area(DRA) of the central aortic pulse wave(Arteriograph);(4) CFR using Doppler echocardiography; and(5) blood levels of lipoprotein-phospholipase A2(LpPLA2).RESULTS: After adjustment for age, sex, blood pressure parameter, lipidemic, diabetic and smoking status, we found that coronary flow reserve was independently related to AIx(b =-0.38, r = 0.009), DAI(b = 0.36, P = 0.014), DRA(b = 0.39, P = 0.005) and RT(b =-0.29,P = 0.026). Additionally, patients with CFR < 2.5 had higher PWVc(11.6 ± 2.3 vs 10.2 ± 1.4 m/s, P = 0.019), SBPc(139.1 ± 17.8 vs 125.2 ± 19.1 mm Hg, P = 0.026), AIx(38.2% ± 14.8% vs 29.4% ± 15.1%, P = 0.011) and lower RHI(1.26 ± 0.28 vs 1.50 ± 0.46, P = 0.012), DAI(44.3% ± 7.9% vs 53.9% ± 6.7%, P = 0.008), DRA(42.2 ± 9.6 vs 51.6 ± 11.4, P = 0.012) and Lp PLA2(268.1 ± 91.9 vs 199.5 ± 78.4 ng/m L, P = 0.002) compared with those with CFR ≥ 2.5. Elevated Lp PLA2 was related with reduced CFR(r =-0.33, P = 0.001), RHI(r =-0.37, P < 0.001) and DRA(r =-0.35, P = 0.001) as well as increased PWVc(r = 0.34, P = 0.012) and AIx(r = 0.34, P = 0.001). CONCLUSION: Abnormal arterial wave reflections are related with impaired coronary flow reserve despite successful revascularization in CAD patients. There is a common inflammatory link between impaired aortic wall properties, endothelial dysfunction and coronary flow impairment in CAD.

  1. Blood flow measurements and clot detection with nearinfrared spectroscopy

    OpenAIRE

    Rossow, MJ; Gatto, R.; D'amico, E.; Mantulin, WW; Gratton, E

    2006-01-01

    Detecting impeded blood flow and locating the clot causing it is a major challenge in neurosurgery. We propose an instrument that uses near-infrared spectroscopy to simultaneously detect clots and measure blood flow. © 2006 Optical Society of America.

  2. Current status of assessment of fractional flow reserve

    Institute of Scientific and Technical Information of China (English)

    FANG Yi-min; Grisana Grootenhuijs-Triyasut; Pieter A. Doevendans; Yolande Appelman

    2009-01-01

    @@ Coronary angiography presently remains the main method for the diagnosis and instruction of epicardial coronary disease. However, precise characterization of the significance for any given stenosis is limited by the inability to identify intermediate coronary lesions responsible for ischemia.1-3 In clinical practice, in addition to the assessment of the anatomical details of vessel narrowing, a more precise assessment of the impediment to coronary blood flow has become extremely important. At present, several physiological parameters have been introduced to improve discrimination in functional coronary lesion severity during cardiac catheterization.

  3. Glial and neuronal control of brain blood flow

    DEFF Research Database (Denmark)

    Attwell, David; Buchan, Alastair M; Charpak, Serge

    2010-01-01

    Blood flow in the brain is regulated by neurons and astrocytes. Knowledge of how these cells control blood flow is crucial for understanding how neural computation is powered, for interpreting functional imaging scans of brains, and for developing treatments for neurological disorders. It is now...... in our understanding of cerebral blood flow control have important implications for the development of new therapeutic approaches....

  4. Clinical use of optical coherence tomography and fractional flow reserve

    Directory of Open Access Journals (Sweden)

    Ivanović Vladimir

    2016-01-01

    Full Text Available Introduction. The aim of each diagnostic method is to serve as a guide in deciding about the right patient treatment. During myocardial revascularization the decision to perform revascularization is usually not easy to make, especially in case of borderline stenosis. It has been proven that it is not enough to base morphological evaluation of coronary artery vessel stenosis solely on angiography. It is necessary to include additional modern diagnostic methods for functional analysis and detailed morphological analysis using fractional flow reserve (FFR and optical coherence tomography (OCT, respectively. Case reports. In the first case report we showed the significance of morphological analysis using OCT and proved that it was not lumen stenosis. The second and the third case reports showed the complementarity between functional analysis (FFR and morphological analysis (OCT of stenosis in solving a complex coronary disease. The fourth case report showed the significance of OCT in dealing with the recurrent stent restenosis. Conclusion. By these short case reports we confirmed that percutaneous coronary intervention (PCI guided by angiography is definitely not enough in deciding about myocardial revascularization especially in patients with a complex coronary disease. In certain cases FFR and OCT procedures can be complementary methods and improve quality of revascularization, particularly in the case of recurrent in-stent restenosis.

  5. Fractional flow reserve as a surrogate for inducible myocardial ischaemia.

    Science.gov (United States)

    van de Hoef, Tim P; Meuwissen, Martijn; Escaned, Javier; Davies, Justin E; Siebes, Maria; Spaan, Jos A E; Piek, Jan J

    2013-08-01

    Documentation of inducible myocardial ischaemia, related to the coronary stenosis of interest, is of increasing importance in lesion selection for percutaneous coronary intervention (PCI). Fractional flow reserve (FFR) is an easily understood, routine diagnostic modality that has become part of daily clinical practice, and is used as a surrogate technique for noninvasive assessment of myocardial ischaemia. However, the application of a single, discrete, cut-off value for FFR-guided lesion selection for PCI, and its adoption in contemporary revascularization guidelines, has limited the requirement for a thorough understanding of the physiological basis of FFR. This limitation constitutes an obstacle for the adequate use and interpretation of this technique, and also for the understanding of new and future modalities of physiological functional intracoronary testing. In this Review, we revisit the fundamental elements of coronary physiology in the absence or presence of coronary artery disease. We provide insight into three essential characteristics of FFR as a diagnostic tool in contemporary clinical practice--the theoretical framework of FFR and its associated limitations; the characteristics and role of FFR as a surrogate for noninvasively assessed myocardial ischaemia; and the requirement and associated caveats of potent vasodilatory drugs to induce maximal vasodilatation of the coronary vascular bed.

  6. Quantification of myocardial blood flow with {sup 82}Rb dynamic PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lortie, Mireille; Beanlands, Rob S.B.; Yoshinaga, Keiichiro; Klein, Ran; DaSilva, Jean N.; DeKemp, Robert A. [University of Ottawa Heart Institute, Cardiac PET Centre, Ottawa, ON (Canada)

    2007-11-15

    The PET tracer {sup 82}Rb is commonly used to evaluate regional perfusion defects for the diagnosis of coronary artery disease. There is limited information on the quantification of myocardial blood flow and flow reserve with this tracer. The goal of this study was to investigate the use of a one-compartment model of {sup 82}Rb kinetics for the quantification of myocardial blood flow. Fourteen healthy volunteers underwent rest and dipyridamole stress imaging with both {sup 13}N-ammonia and {sup 82}Rb within a 2-week interval. Myocardial blood flow was estimated from the time-activity curves measured with {sup 13}N-ammonia using a standard two-compartment model. The uptake parameter of the one-compartment model was estimated from the time-activity curves measured with {sup 82}Rb. To describe the relationship between myocardial blood flow and the uptake parameter, a nonlinear extraction function was fitted to the data. This function was then used to convert estimates of the uptake parameter to flow estimates. The extraction function was validated with an independent data set obtained from 13 subjects with documented evidence of coronary artery disease (CAD). The one-compartment model described {sup 82}Rb kinetics very well (median R-square = 0.98). The flow estimates obtained with {sup 82}Rb were well correlated with those obtained with {sup 13}N-ammonia (r = 0.85), and the best-fit line did not differ significantly from the identity line. Data obtained from the subjects with CAD confirmed the validity of the estimated extraction function. It is possible to obtain accurate estimates of myocardial blood flow and flow reserve with a one-compartment model of {sup 82}Rb kinetics and a nonlinear extraction function. (orig.)

  7. Collateral blood flow in different cerebrovascular hierarchy provides endogenous protection in cerebral ischemia.

    Science.gov (United States)

    Luo, Chuanming; Liang, Fengyin; Ren, Huixia; Yao, Xiaoli; Liu, Qiang; Li, Mingyue; Qin, Dajiang; Yuan, Ti-Fei; Pei, Zhong; Su, Huanxing

    2016-11-15

    Collateral blood flow as vascular adaptions to focal cerebral ischemia is well recognized. However, few studies directly investigate the dynamics of collateral vessel recruitment in vivo and little is known about the effect of collateral blood flow in different cerebrovascular hierarchy on the neuropathology after focal ischemic stroke. Here, we report that collateral blood flow is critically involved in blood vessel compensations following regional ischemia. We occluded a pial arteriole using femtosecond laser ablating under the intact thinned skull and documented the changes of collateral flow around the surface communication network and between the surface communication network and subsurface microcirculation network using in vivo two photon microscopy imaging. Occlusion of the pial arteriole apparently increased the diameter and collateral blood flow of its leptomeningeal anastomoses, which significantly reduced the cortical infarction size. This result suggests that the collateral flow via surface communicating network connected with leptomeningeal anastomoses could greatly impact on the extent of infarction. We then further occluded the target pial arteriole and all of its leptomeningeal anastomoses. Notably, this type of occlusion led to reversals of blood flow in the penetrating arterioles mainly proximal to the occluded pial arteriole in a direction from the subsurface microcirculation network to surface arterioles. Interesting, the cell death in the area of ischemic penumbra was accelerated when we performed occlusion to cease the reversed blood flow in those penetrating arterioles, suggesting that the collateral blood flow from subsurface microcirculation network exerts protective roles in delaying cell death in the ischemic penumbra. In conclusion, we provide the first experimental evidence that collateral blood vessels at different cerebrovascular hierarchy are endogenously compensatory mechanisms in brain ischemia. This article is protected by

  8. Blood flow in healed and inflamed periodontal tissues of dogs

    Energy Technology Data Exchange (ETDEWEB)

    Hock, J.M.; Kim, S.

    1987-01-01

    The objectives of this study were to determine if increased blood flow associated with gingivitis would decrease following resolution of gingival inflammation in dogs with periodontitis; if increased blood flow in inflamed gingiva was associated with changes in the blood flow of alveolar bone, and if blood flow in gingiva and alveolar bone increased if periodontitis was reactivated by ligating teeth. Regional blood flow was measured in dogs with pre-existing periodontitis, using radioisotope-labelled, plastic microspheres. In the first experiment on 4 adult Beagle dogs, teeth in the left jaws were treated to resolve the periodontitis, while teeth in the right jaws were not treated. Gingival and bone blood flow were measured after 12 wk. Blood flow was significantly (p<0.05) lower in non-inflamed healed gingiva (32.1 +- 2.7 ml/min/100 g) than in inflamed gingiva (46.1 +- 5.3 ml/min/100 g). No differences in the blood flow of the alveolar bone underlying inflamed or non-inflamed gingiva were present. In the second experiment, the right mandibular teeth of 5 dogs were treated to resolve periodontitis while teeth in the other quadrants were ligated for 4, 10 or 12 wk. The duration of ligation did not alter blood flow. Gingival blood flow around ligated maxillary and mandibular teeth was comparable and approximately 54% higher than around non-ligated teeth (p<0.03). The difference in blood flow between gingiva with G.I.>1 and gingiva with G.I.<2 was significant (p<0.04). Blood flow in bone was not altered by changes in the inflammatory status of the overlying gingiva. The findings suggest that changes in blood flow associated with inflammation are reversible and that blood flow alveolar bone is regulated independently of gingival blood flow.

  9. Coronary Computed Tomography Angiography Derived Fractional Flow Reserve and Plaque Stress

    DEFF Research Database (Denmark)

    Nørgaard, Bjarne Linde; Leipsic, Jonathon; Koo, Bon-Kwon;

    2016-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is an independent prognosticator in patients with coronary artery disease and the gold standard for decision making in coronary revascularization. The integration of computational fluid dynamics and quantitative anatomic...

  10. Skin blood flow changes during apneic spells in preterm infants

    NARCIS (Netherlands)

    Suichies, H.E.; Aarnoudse, J.G.; Okken, A.; Jentink, H.W.; Mul, de F.F.M.; Greve, J.

    1989-01-01

    Changes in skin blood flow during apneic spells were determined in 18 preterm infants using a diode laser Doppler flow meter without light conducting fibres. Heart rate, nasal air flow, impedance pneumography, skin and incubator temperature and laser Doppler skin blood flow were recorded simultaneou

  11. Nonlinear interactions in renal blood flow regulation

    DEFF Research Database (Denmark)

    Marsh, Donald J.; Sosnovtseva, Olga; Chon, Ki H.

    2005-01-01

    , identical except for the strength of TGF input, with a third, fixed resistance segment representing prearteriolar vessels. The two arteriolar segments are electrically coupled. The arteriolar, glomerular, and tubular models are linked; TGF modulates arteriolar circumference, which determines vascular...... resistance and glomerular capillary pressure. The model couples TGF input to voltage-gated Ca channels. It predicts autoregulation of GFR and renal blood flow, matches experimental measures of tubular pressure and macula densa NaCl concentration, and predicts TGF-induced oscillations and a faster smaller...

  12. Absolute quantification of myocardial blood flow.

    Science.gov (United States)

    Yoshinaga, Keiichiro; Manabe, Osamu; Tamaki, Nagara

    2016-07-21

    With the increasing availability of positron emission tomography (PET) myocardial perfusion imaging, the absolute quantification of myocardial blood flow (MBF) has become popular in clinical settings. Quantitative MBF provides an important additional diagnostic or prognostic information over conventional visual assessment. The success of MBF quantification using PET/computed tomography (CT) has increased the demand for this quantitative diagnostic approach to be more accessible. In this regard, MBF quantification approaches have been developed using several other diagnostic imaging modalities including single-photon emission computed tomography, CT, and cardiac magnetic resonance. This review will address the clinical aspects of PET MBF quantification and the new approaches to MBF quantification.

  13. Net Capital Flows, Macroeconomic Shocks and Reserve Assets. The Case of Argentina (1994-2013

    Directory of Open Access Journals (Sweden)

    Luis N. Lanteri

    2014-06-01

    Full Text Available International reserves have been used as a source of protection against the vulnerability of the balance of payments, or alternatively, as an attempt to keep a competitive real exchange rate and to promote exports. This paper explores the correlation between the net capital flows and reserves. Similarly, the impact of some macroeconomic shocks on that variable is assessed. Estimates are carried out through both, the VEC (Vector Error Correction models and quarterly data of the Argentine economy for the period 1994-2013. Results show a negative correlation between international reserves and net capital flows (reserve accumulation through current account surpluses. At the same time, the expansionary fiscal policies and the continuing and widespread price increases would adversely affect the reserves.

  14. Capillary pericytes regulate cerebral blood flow in health and disease

    DEFF Research Database (Denmark)

    Hall, Catherine N; Reynell, Clare; Gesslein, Bodil;

    2014-01-01

    Increases in brain blood flow, evoked by neuronal activity, power neural computation and form the basis of BOLD (blood-oxygen-level-dependent) functional imaging. Whether blood flow is controlled solely by arteriole smooth muscle, or also by capillary pericytes, is controversial. We demonstrate...... blood flow, capillaries dilate before arterioles and are estimated to produce 84% of the blood flow increase. In pathology, ischaemia evokes capillary constriction by pericytes. We show that this is followed by pericyte death in rigor, which may irreversibly constrict capillaries and damage the blood......-brain barrier. Thus, pericytes are major regulators of cerebral blood flow and initiators of functional imaging signals. Prevention of pericyte constriction and death may reduce the long-lasting blood flow decrease that damages neurons after stroke....

  15. Decorrelation-based blood flow velocity estimation: effect of spread of flow velocity, linear flow velocity gradients, and parabolic flow.

    NARCIS (Netherlands)

    Lupotti, F.A.; Steen, A.F.W. van der; Mastik, F.; Korte, C.L. de

    2002-01-01

    In recent years, a new method to measure transverse blood flow, based on the decorrelation of the radio frequency (RF) signals has been developed. In this paper, we investigated the influence of nonuniform flow on the velocity estimation. The decorrelation characteristics of transverse blood flow us

  16. Regional cerebral blood flow in schizophrenics

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, J.; Ohta, Y.; Nakane, Y.; Mori, H.; Hirota, N.; Yonekura, M.

    1987-01-01

    The present study on schizophrenics dealt with the relationship of regional cerebral blood flow (rCBF) to age, disease duration, and treatment length with chlorpromazine hydrochloride (CPZ). Regional cerebral blood flow in 28 cerebral regions of interest was measured by iv injection of /sup 133/X in 54 schizophrenic patients and 39 healthy volunteers. Neither age nor dosage of CPZ significantly influenced rCBF. All patients, including 11 treated for a short period of time (6 months or less), were characterized by having a decreased rCBF over the whole cerebrum. Thirty-four patients treated for a long period of time (2 years or more) had a varied rCBF distribution in the left hemisphere, with the most predominant feature being the decrease in rCBF in the frontal lobe (i.e., hypofrontality); however, there was no linear correlation between rCBF and disease duration. A decreased rCBE in the right occipital region was seen in patients with paranoid schizophrenia, suggesting that manifestations of symptoms may depend on disturbed regions. These results suggest that cerebral dysfunction in schizophrenic patients may not be restricted to the frontal lobe, but cover the whole cerebrum, and that nonuniform dysfunction in various regions of the cerebrum, including the frontal lobe, may be involved in manifestations of symptoms.

  17. Cerebral blood flow tomography with xenon-133

    Energy Technology Data Exchange (ETDEWEB)

    Lassen, N.A.

    1985-10-01

    Cerebral blood flow (CBF) can be measured tomographically by inhalation of Xenon-/sup 133/. The calculation is based on taking a sequence of tomograms during the wash-in and wash-out phase of the tracer. Due to the dynamic nature of the process, a highly sensitive and fast moving single photon emission computed tomograph (SPECT) is required. Two brain-dedicated SPECT systems designed for this purpose are mentioned, and the method is described with special reference to the limitations inherent in the soft energy of the 133Xe primary photons. CBF tomography can be used for a multitude of clinical and investigative purposes. This article discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use of other tracers for CBF tomography using SPECT is summarized with emphasis on the /sup 99m/Tc chelates that freely pass the intact blood-brain barrier. The highly sensitive brain-dedicated SPECT systems described are a prerequisite for achieving high resolution tomograms with such tracers.

  18. Tissue blood flow mapping using laser technology

    Science.gov (United States)

    Wardell, Karin; Linden, Maria; Nilsson, Gert E.

    1995-03-01

    By the introduction of the laser Doppler perfusion imager (LDPI) the microvascular blood flow in a tissue area can be mapped by sequentially moving a laser beam over the tissue. The measurement is performed without touching the tissue and the captured perfusion values in the peripheral circulation are presented as a color-coded image. In the ordinary LDPI-set-up, 64 X 64 measurement sites cover an area in the range of about 10 - 150 cm2 depending on system settings. With a high resolution modification, recordings can be done on tissue areas as small as 1 cm2. This high resolution option has been assessed in animal models for the mapping of small vessels. To be able to record not only spatial but also temporal perfusion components of tissue blood flow, different local area scans (LAS) have been developed. These include single point recording as well as integration of either 2 X 2, 3 X 3, or 4 X 4 measurement sites. The laser beam is repeatedly moved in a quadratic pattern over the small tissue area of interest and the output value constitutes the average perfusion of all captured values within the actual region. For the evaluation, recordings were performed on healthy volunteers before and after application of a vasodilatating cream on the dorsal side of the hand.

  19. Low cerebral blood flow in hypotensive perinatal distress

    DEFF Research Database (Denmark)

    Lou, H C; Lassen, N A; Friis-Hansen, B

    1977-01-01

    was used for the cerebral blood flow measurements. The study confirmed that perinatal distress may be associated with low arterial blood pressure, and it was shown that cerebral blood flow is very low, 20 ml/100 g/min or less, in hypotensive perinatal distress. It is concluded that cerebral ischaemia plays...

  20. Effects of hypoxia on coronary flow reserve as determined by myocardial contrast echocardiography in swine

    Institute of Scientific and Technical Information of China (English)

    YANG Yuan 杨源; LI Shu-qing 李树清; Barry Peters; Anthony N DeMaria

    2004-01-01

    Background Time-intensity curves derived from microbubble destruction/refilling sequences and recorded using myocardial contrast echocardiography (MCE) can provide parameters that correlate with coronary blood flow. The response of these parameters to adenosine vasodilatation correlates with coronary flow reserve (CFR) measured by fluorescent microsphere techniques (FMT). Currently, no data exist regarding the effect of physiological variables, such as hypoxia, on the determination of CFR by MCE. The purpose of this study was to define the effects of decreases in blood partial pressure of oxygen (PO2) on CFR as measured by MCE. Methods Studies were performed in 9 closed chest swine. Low-energy, real-time MCE was performed with commercial instruments in short axis view at papillary muscle level while infusing BR1 at 30 ml/h. High-energy ultrasound bursts (referred to as FLASH frames) destroyed the bubbles every 15 cardiac cycles, and resultant time-intensity curves derived from these sequences were fitted to the exponential function y = A (1-e-bt) +c, from which the rate of signal rise (b) was obtained. CFR was calculated as the ratio of b values after adenosine infusion to baseline and was obtained during the control period and after decreasing blood PO2 by giving nitrogen via a respirator to create artificial hypoxic conditions. CFR was independently determined by FMT. Results Nitrogen led to significant decreases in mean PO2, from (120.6±18.9) mmHg to (51.8±15.9) mmHg (P0.05 compared with the baseline). Conclusions CFR values diminish under hypoxic conditions according to both MCE and FMT. The reductions in CFR involve both an increase in resting values and a decrease in post adenosine measurements, as determined by both techniques. The reduction in CFR under hypoxia is slightly greater using MCE than using FMT. Physiological variables, such as hypoxia, must be taken into consideration when assessing CFR by MCE.

  1. Intraoperative cerebral blood flow imaging of rodents

    Science.gov (United States)

    Li, Hangdao; Li, Yao; Yuan, Lu; Wu, Caihong; Lu, Hongyang; Tong, Shanbao

    2014-09-01

    Intraoperative monitoring of cerebral blood flow (CBF) is of interest to neuroscience researchers, which offers the assessment of hemodynamic responses throughout the process of neurosurgery and provides an early biomarker for surgical guidance. However, intraoperative CBF imaging has been challenging due to animal's motion and position change during the surgery. In this paper, we presented a design of an operation bench integrated with laser speckle contrast imager which enables monitoring of the CBF intraoperatively. With a specially designed stereotaxic frame and imager, we were able to monitor the CBF changes in both hemispheres during the rodent surgery. The rotatable design of the operation plate and implementation of online image registration allow the technician to move the animal without disturbing the CBF imaging during surgery. The performance of the system was tested by middle cerebral artery occlusion model of rats.

  2. Mapping blood flow directionality in the human brain.

    Science.gov (United States)

    Park, Sung-Hong; Do, Won-Joon; Choi, Seung Hong; Zhao, Tiejun; Bae, Kyongtae Ty

    2016-07-01

    Diffusion properties of tissue are often expressed on the basis of directional variance, i.e., diffusion tensor imaging. In comparison, common perfusion-weighted imaging such as arterial spin labeling yields perfusion in a scalar quantity. The purpose of this study was to test the feasibility of mapping cerebral blood flow directionality using alternate ascending/descending directional navigation (ALADDIN), a recently-developed arterial spin labeling technique with sensitivity to blood flow directions. ALADDIN was applied along 3 orthogonal directions to assess directional blood flow in a vector form and also along 6 equally-spaced directions to extract blood flow tensor matrix (P) based on a blood flow ellipsoid model. Tensor elements (eigenvalues, eigenvectors, etc) were calculated to investigate characteristics of the blood flow tensor, in comparison with time-of-flight MR angiogram. While the directions of the main eigenvectors were heterogeneous throughout the brain, regional clusters of blood flow directionality were reproducible across subjects. The technique could show heterogeneous blood flow directionality within and around brain tumor, which was different from that of the contralateral normal side. The proposed method is deemed to provide information of blood flow directionality, which has not been demonstrated before. The results warrant further studies to assess changes in the directionality map as a function of scan parameters, to understand the signal sources, to investigate the possibility of mapping local blood perfusion directionality, and to evaluate its usefulness for clinical diagnosis.

  3. The effect of hyperosmotic solutions on the hepatic blood flow

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik Sahl; Tygstrup, N

    1993-01-01

    The present study was undertaken in order to measure the effect of hyperosmotic solutions on portal and hepatic blood flow. In five anaesthetized pigs without arterial blood supply to the liver, portal blood flow rate was measured (electromagnetic flowmeter) during 5 min lasting intravenous infus...... for these osmotic effects are not known, but they have to be taken into consideration in studies of the portal and hepatic blood flow.......The present study was undertaken in order to measure the effect of hyperosmotic solutions on portal and hepatic blood flow. In five anaesthetized pigs without arterial blood supply to the liver, portal blood flow rate was measured (electromagnetic flowmeter) during 5 min lasting intravenous...

  4. Detection of Low-volume Blood Loss: Compensatory Reserve Versus Traditional Vital Signs

    Science.gov (United States)

    2014-01-01

    Detection of low-volume blood loss: Compensatory reserve versus traditional vital signs Camille L. Stewart, MD, Jane Mulligan , PhD, Greg Z. Grudic... Mulligan J., Grudic G. Z., Convertino V. A., Moulton S. L., 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S...Jane Mulligan (own ership), Greg Z. Grudic (ownership), and Steven L. Moulton (owner ship). This work is supported by the US Army Medical Research and

  5. Cerebral blood flow simulations in realistic geometries

    Directory of Open Access Journals (Sweden)

    Szopos Marcela

    2012-04-01

    Full Text Available The aim of this work is to perform the computation of the blood flow in all the cerebral network, obtained from medical images as angiographies. We use free finite elements codes as FreeFEM++. We first test the code on analytical solutions in simplified geometries. Then, we study the influence of boundary conditions on the flow and we finally perform first computations on realistic meshes. L’objectif est ici de simuler l’écoulement sanguin dans tout le réseau cérébral (artériel et veineux obtenu à partir d’angiographies cérébrales 3D à l’aide de logiciels d’éléments finis libres, comme FreeFEM++. Nous menons d’abord une étude détaillée des résultats sur des solutions analytiques et l’influence des conditions limites à imposer dans des géométries simplifiées avant de travailler sur les maillages réalistes.

  6. Myocardial blood flow assessment with {sup 82}rubidium-PET imaging in patients with left bundle branch block

    Energy Technology Data Exchange (ETDEWEB)

    Falcao, Andrea; Chalela, William; Giorgi, Maria Clementina; Imada, Rodrigo; Soares Junior, Jose; Do Val, Renata; Oliveira, Marco Antonio; Izaki, Marisa; Kalil Filho, Roberto; Meneghetti, Jose C., E-mail: andrea.falcao@incor.usp.br [Universidade de Sao Paulo (InCor/USP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Instituto do Coracao

    2015-11-15

    Objectives: Perfusion abnormalities are frequently seen in Single Photon Emission Computed Tomography (SPECT) when a left bundle branch block is present. A few studies have shown decreased coronary flow reserve in the left anterior descending territory, regardless of the presence of coronary artery disease. Objective: we sought to investigate rubidium-82 ({sup 82}Rb) positron emission tomography imaging in the assessment of myocardial blood flow and coronary flow reserve in patients with left bundle branch block. Methods: thirty-eight patients with left bundle branch block (GI), median age 63.5 years, 22 (58%) female, 12 with coronary artery disease (≥70%; GI-A) and 26 with no evidence of significant coronary artery disease (GI-B), underwent rest-dipyridamole stress {sup 82}Rb-positron emission tomography with absolute quantitative flow measurements using Cedars-Sinai software (mL/min/g). The relative myocardial perfusion and left ventricular ejection fraction were assessed in 17 segments. These parameters were compared with those obtained from 30 patients with normal {sup 82}Rb-positron emission tomography studies and without left bundle branch block (GII). Results: stress myocardial blood flow and coronary flow reserve were significantly lower in GI than in GII (p>0.05). The comparison of coronary flow reserve between GI-A and GI-B showed that it was different from the global coronary flow reserve (p<0.05) and the stress flow was significantly lower in the anterior than in the septal wall for both groups. Perfusion abnormalities were more prevalent in GI-A (p=0.06) and the left ventricular ejection fraction was not different between GI-A and GI-B, whereas it was lower in GI than in GII (p<0.001). Conclusion: the data confirm that patients with left bundle branch block had decreased myocardial blood flow and coronary flow reserve and coronary flow reserve assessed by {sup 82}Rb-positron emission tomography imaging may be useful in identifying coronary artery

  7. Dynamic Effect of Rolling Massage on Blood Flow

    Institute of Scientific and Technical Information of China (English)

    CHEN Yan-Yan; YI Hou-Hui; LI Hua-Bing; FANG Hai-Ping

    2009-01-01

    The Chinese traditional medical massage has been used as a natural therapy to eliminate some diseases.Here, the effect of the rolling massage frequency to the blood flow in the blood vessels under the rolling massage manipulation is studied by the lattice Boltzmann simulation.The simulation results show that when the frequency is smaller than or comparable to the putsatile frequency of the blood flow, the effect on the blood flux by the rolling massage is small.On the contrast, if the frequency is twice or more times of the putsatile frequency of the blood flow, the blood flux is greatly enhanced and increases linearly with respect to the frequency.Similar behavior has also been observed on the shear stress on the blood vessel waits.The result is helpful for understanding that the rolling massage has the function of promoting the blood circulation and removing the blood stasis.

  8. Dynamic Effect of Rolling Massage on Blood Flow

    Science.gov (United States)

    Chen, Yan-Yan; Yi, Hou-Hui; Li, Hua-Bing; Fang, Hai-Ping

    2009-02-01

    The Chinese traditional medical massage has been used as a natural therapy to eliminate some diseases. Here, the effect of the rolling massage frequency to the blood flow in the blood vessels under the rolling massage manipulation is studied by the lattice Boltzmann simulation. The simulation results show that when the frequency is smaller than or comparable to the pulsatile frequency of the blood flow, the effect on the blood flux by the rolling massage is small. On the contrast, if the frequency is twice or more times of the pulsatile frequency of the blood flow, the blood flux is greatly enhanced and increases linearly with respect to the frequency. Similar behavior has also been observed on the shear stress on the blood vessel walls. The result is helpful for understanding that the rolling massage has the function of promoting the blood circulation and removing the blood stasis.

  9. Multiscale modeling of blood flow: from single cells to blood rheology.

    Science.gov (United States)

    Fedosov, Dmitry A; Noguchi, Hiroshi; Gompper, Gerhard

    2014-04-01

    Mesoscale simulations of blood flow, where the red blood cells are described as deformable closed shells with a membrane characterized by bending rigidity and stretching elasticity, have made much progress in recent years to predict the flow behavior of blood cells and other components in various flows. To numerically investigate blood flow and blood-related processes in complex geometries, a highly efficient simulation technique for the plasma and solutes is essential. In this review, we focus on the behavior of single and several cells in shear and microcapillary flows, the shear-thinning behavior of blood and its relation to the blood cell structure and interactions, margination of white blood cells and platelets, and modeling hematologic diseases and disorders. Comparisons of the simulation predictions with existing experimental results are made whenever possible, and generally very satisfactory agreement is obtained.

  10. EFFECT OF INCREASED WHOLE-BLOOD VISCOSITY ON REGIONAL BLOOD FLOWS IN CHRONICALLY HYPOXEMIC LAMBS

    NARCIS (Netherlands)

    DALINGHAUS, M; KNOESTER, H; GRATAMA, JWC; VANDERMEER, J; ZIJLSTRA, WG; KUIPERS, JRG

    1994-01-01

    In chronic hypoxemia blood flow and oxygen supply to vital organs are maintained, but to nonvital organs they are decreased. We measured organ blood flows (microspheres) and whole blood viscosity in 10 chronically hypoxemic lambs, with an atrial septal defect and pulmonary stenosis, and in 8 control

  11. Prediction of Anomalous Blood Viscosity in Confined Shear Flow

    Science.gov (United States)

    Thiébaud, Marine; Shen, Zaiyi; Harting, Jens; Misbah, Chaouqi

    2014-06-01

    Red blood cells play a major role in body metabolism by supplying oxygen from the microvasculature to different organs and tissues. Understanding blood flow properties in microcirculation is an essential step towards elucidating fundamental and practical issues. Numerical simulations of a blood model under a confined linear shear flow reveal that confinement markedly modifies the properties of blood flow. A nontrivial spatiotemporal organization of blood elements is shown to trigger hitherto unrevealed flow properties regarding the viscosity η, namely ample oscillations of its normalized value [η]=(η-η0)/(η0ϕ) as a function of hematocrit ϕ (η0=solvent viscosity). A scaling law for the viscosity as a function of hematocrit and confinement is proposed. This finding can contribute to the conception of new strategies to efficiently detect blood disorders, via in vitro diagnosis based on confined blood rheology. It also constitutes a contribution for a fundamental understanding of rheology of confined complex fluids.

  12. Cerebellar blood flow in methylmercury poisoning (Minamata disease)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K.; Korogi, Y.; Tomiguchi, S.; Takahashi, M. [Dept. of Radiology, Kumamoto University School of Medicine (Japan); Okajima, T. [Dept. of Neurology, Johnan Hospital, Maihara, Johnan-mochi (Japan); Sato, H. [Dept. of Neurology, Minamata City General Hospital and Medical Centre (Japan)

    2001-04-01

    We looked at regional cerebellar blood flow in patients with Minamata disease (MD) using technetium-99 m ethyl cysteinate dimer (99m-Tc-ECD). We carried out single-photon emission computed tomography (SPECT) on 15 patients with MD (eight men, seven women, aged 51-78 years, mean 70.5 years) and 11 control subjects (eight men, three women, aged 62-80 years, mean 72.5 years). Regional blood flow was measured in the superior, middle, and inferior portions of the cerebellar hemispheres, and the frontal, temporal and occipital cerebral lobes. The degree of cerebellar atrophy was assessed on MRI. There were significant differences in regional blood flow in all parts of the cerebellum between patients and control, but no significant decrease was observed in the cerebrum. Blood flow was lower in the inferior cerebellum than in the other parts. Even in patients without cerebellar atrophy, flow was significantly decreased regional blood flow in the inferior part. (orig.)

  13. Cerebellar blood flow in methylmercury poisoning (Minamata disease).

    Science.gov (United States)

    Itoh, K; Korogi, Y; Tomiguchi, S; Takahashi, M; Okajima, T; Sato, H

    2001-04-01

    We looked at regional cerebellar blood flow in patients with Minamata disease (MD) using technetium-99m ethyl cysteinate dimer (99m-Tc-ECD). We carried out single-photon emission computed tomography (SPECT) on 15 patients with MD (eight men, seven women, aged 51-78 years, mean 70.5 years) and 11 control subjects (eight men, three women, aged 62-80 years, mean 72.5 years). Regional blood flow was measured in the superior, middle, and inferior portions of the cerebellar hemispheres, and the frontal, temporal and occipital cerebral lobes. The degree of cerebellar atrophy was assessed on MRI. There were significant differences in regional blood flow in all parts of the cerebellum between patients and control, but no significant decrease was observed in the cerebrum. Blood flow was lower in the inferior cerebellum than in the other parts. Even in patients without cerebellar atrophy, flow was significantly decreased regional blood flow in the inferior part.

  14. RELATIONS OF ENDOTHELIAL FUNCTION AND BLOOD FLOW IN BRACHIAL ARTERY AND CORONARY ARTERY

    Institute of Scientific and Technical Information of China (English)

    孙寅光; 沈卫峰; 施仲伟; 张大东

    2003-01-01

    Objective To determine the relations between endothelium dependent vasodilator function and blood flow in the brachial and coronary arteries in patients with suspected coronary artery disease.MethodsTwenty eight patients with suspected coronary artery disease underwent brachial artery endothelial function test by using high resolution B mode ultrasound before coronary angiography (CAG) and coronary flow reserve (CFR) test by using intracoronary Doppler technique. The correlation of coronary artery dilatation induced by an increase in blood flow after intracoronary adenosine infusion and brachial artery flow mediated dilatation (FMD) following reactive hyperemia was evaluated. The relation between the change of brachial artery blood flow and CFR was also studied.ResultsThere was a positive correlation between brachial FMD and percent change of coronary diameter after adenosine infusion (12.50%±9.35% vs 11.38%±7.55%, r=0.425,P=0.02). There was also a weak negative relation between brachial flow change following reactive hyperemia and CFR (r=0.397, P=0.04).ConclusionThere is a correlation between the coronary endothelial function and the CFR by ultrasonic determination of brachial flow changes following reactive hyperemia.

  15. Subcutaneous blood flow during insulin-induced hypoglycaemia

    DEFF Research Database (Denmark)

    Hilsted, J; Madsbad, S; Sestoft, L

    1982-01-01

    Subcutaneous blood flow was measured preceding insulin-induced hypoglycaemia, at the onset of hypoglycaemic symptoms and 2 h later in juvenile diabetics with and without autonomic neuropathy and in normal males. In all groups subcutaneous blood flow decreased at the onset of hypoglycaemic symptoms...... compared with pre-hypoglycaemic flow. Two hours after onset of hypoglycaemic symptoms, subcutaneous blood flow was still significantly decreased compared with pre-hypoglycaemic flow. In normal subjects local nerve blockade had no effect on blood flow changes during hypoglycaemia, whereas local alpha......-receptor blockade abolished the vasoconstrictor response. We suggest that circulating catecholamines stimulating vascular alpha-receptors are probably responsible for flow reduction in the subcutaneous tissue during hypoglycaemia....

  16. Pulsatile blood flow in Abdominal Aortic Aneurysms

    Science.gov (United States)

    Salsac, Anne-Virginie; Lasheras, Juan C.; Singel, Soeren; Varga, Chris

    2001-11-01

    We discuss the results of combined in-vitro laboratory measurements and clinical observations aimed at determining the effect that the unsteady wall shear stresses and the pressure may have on the growth and eventual rupturing of an Abdominal Aortic Aneurysm (AAA), a permanent bulging-like dilatation occurring near the aortic bifurcation. In recent years, new non-invasive techniques, such as stenting, have been used to treat these AAAs. However, the development of these implants, aimed at stopping the growth of the aneurysm, has been hampered by the lack of understanding of the effect that the hemodynamic forces have on the growth mechanism. Since current in-vivo measuring techniques lack the precision and the necessary resolution, we have performed measurements of the pressure and shear stresses in laboratory models. The models of the AAA were obtained from high resolution three-dimensional CAT/SCANS performed in patients at early stages of the disease. Preliminary DPIV measurements show that the pulsatile blood flow discharging into the cavity of the aneurysm leads to large spikes of pressure and wall shear stresses near and around its distal end, indicating a possible correlation between the regions of high wall shear stresses and the observed location of the growth of the aneurysm.

  17. Synthetic Capillaries to Control Microscopic Blood Flow

    Science.gov (United States)

    Sarveswaran, K.; Kurz, V.; Dong, Z.; Tanaka, T.; Penny, S.; Timp, G.

    2016-02-01

    Capillaries pervade human physiology. The mean intercapillary distance is only about 100 μm in human tissue, which indicates the extent of nutrient diffusion. In engineered tissue the lack of capillaries, along with the associated perfusion, is problematic because it leads to hypoxic stress and necrosis. However, a capillary is not easy to engineer due to its complex cytoarchitecture. Here, it is shown that it is possible to create in vitro, in about 30 min, a tubular microenvironment with an elastic modulus and porosity consistent with human tissue that functionally mimicks a bona fide capillary using “live cell lithography”(LCL) to control the type and position of cells on a composite hydrogel scaffold. Furthermore, it is established that these constructs support the forces associated with blood flow, and produce nutrient gradients similar to those measured in vivo. With LCL, capillaries can be constructed with single cell precision—no other method for tissue engineering offers such precision. Since the time required for assembly scales with the number of cells, this method is likely to be adapted first to create minimal functional units of human tissue that constitute organs, consisting of a heterogeneous population of 100–1000 cells, organized hierarchically to express a predictable function.

  18. Blood Flow Restricted Exercise and Vascular Function

    Directory of Open Access Journals (Sweden)

    Masahiro Horiuchi

    2012-01-01

    Full Text Available It is established that regular aerobic training improves vascular function, for example, endothelium-dependent vasodilatation and arterial stiffness or compliance and thereby constitutes a preventative measure against cardiovascular disease. In contrast, high-intensity resistance training impairs vascular function, while the influence of moderate-intensity resistance training on vascular function is still controversial. However, aerobic training is insufficient to inhibit loss in muscular strength with advancing age; thus, resistance training is recommended to prevent sarcopenia. Recently, several lines of study have provided compelling data showing that exercise and training with blood flow restriction (BFR leads to muscle hypertrophy and strength increase. As such, BFR training might be a novel means of overcoming the contradiction between aerobic and high-intensity resistance training. Although it is not enough evidence to obtain consensus about impact of BFR training on vascular function, available evidences suggested that BFR training did not change coagulation factors and arterial compliance though with inconsistence results in endothelial function. This paper is a review of the literature on the impact of BFR exercise and training on vascular function, such as endothelial function, arterial compliance, or other potential factors in comparison with those of aerobic and resistance training.

  19. Glial and neuronal control of brain blood flow

    DEFF Research Database (Denmark)

    Attwell, David; Buchan, Alastair M; Charpak, Serge

    2010-01-01

    Blood flow in the brain is regulated by neurons and astrocytes. Knowledge of how these cells control blood flow is crucial for understanding how neural computation is powered, for interpreting functional imaging scans of brains, and for developing treatments for neurological disorders. It is now...

  20. Blood flow velocity in migraine attacks - a transcranial Doppler study

    Energy Technology Data Exchange (ETDEWEB)

    Zwetsloot, C.P.; Caekebeke, J.F.V.; Jansen, J.C.; Odink, J.; Ferrari, M.D. (Rijksuniversiteit Leiden (Netherlands))

    1991-05-01

    A pulsed Doppler device was used to measure blood flow velocities in the common carotid artery, the extracranial part of the internal carotid artery, the external carotid artery, the middle cerebral artery, and the anterior cerebral artery in 31 migraneurs without aura (n=27) and with aura (n=4), both during and ouside an attack. The aims were to compare blood flow velocity during and between migraine attacks and to study asymmetries of the blood flow velocity. Compared with blood flow velocity values obtained in the attack-free interval, blood flow velocity was lower during attacks without aura in both common carotid arteries, but not in the other extra- and intracranial vessels which were examined. However, during attacks of migraine with aura, blood flow velocity tended to be lower in all examined vessels. There were no asymmetries of the blood flow velocity. It is suggested that during migraine attacks without aura there is a dissociation in blood flow regulation in the common carotid and middle cerebral arteries. 20 refs., 2 tabs.

  1. Blood flow rate measurements with indicator techniques revisited

    DEFF Research Database (Denmark)

    Sejrsen, Per; Bülow, Jens

    2009-01-01

    In view of the emerging role, disturbances in regional blood flow rate seem to play in the pathogenesis of the metabolic syndrome; we review the concepts of the classical indicator dilution and washout techniques used for determinations of regional blood flow rate. Prerequisites, assumptions...

  2. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubula...

  3. Data adaptive estimation of transversal blood flow velocities

    DEFF Research Database (Denmark)

    Pirnia, E.; Jakobsson, A.; Gudmundson, E.

    2014-01-01

    , posing natural difficulties due to the complex behaviour of blood flow, and due to the natural orientation of most blood vessels. Recently, a transversal modulation scheme was introduced to induce also an oscillation along the transversal direction, thereby allowing for the measurement of also...... the transversal blood flow. In this paper, we propose a novel data-adaptive blood flow estimator exploiting this modulation scheme. Using realistic Field II simulations, the proposed estimator is shown to achieve a notable performance improvement as compared to current state-of-the-art techniques....

  4. Micro-PIV measurements of blood flow in extraembryonic blood vessels of chicken embryos.

    Science.gov (United States)

    Lee, Jung Yeop; Ji, Ho Seong; Lee, Sang Joon

    2007-10-01

    The hemodynamic characteristics of blood flow are important in the diagnosis of circulatory diseases, since such diseases are related to wall shear stress of cardiovascular vessels. In chicken embryos at early stages of development, it is possible to directly visualize blood flow inside blood vessels. We therefore employed a micro-PIV technique to assess blood flow in extraembryonic venous and arterial blood vessels of chicken embryos, using red blood cells (RBCs) as tracers and obtaining flow images of RBCs using a high-speed CMOS camera. The mean velocity field showed non-Newtonian flow characteristics. The blood flow in two venous vessels merged smoothly into the Y-shaped downstream vein without any flow separation or secondary flow. Vorticity was high in the inner regions, where the radius of curvature varied greatly. A periodic variation of temporally resolved velocity signals, due to beating of the heart, was observed in arterial blood vessels. The pulsating frequency was obtained by fast Fourier transform analysis using the measured velocity data. The measurement technique used here was useful in analyzing the hemodynamic characteristics of in vivo blood flow in chicken embryos.

  5. Exploration of 4D MRI blood flow using stylistic visualization.

    Science.gov (United States)

    van Pelt, Roy; Oliván Bescós, Javier; Breeuwer, Marcel; Clough, Rachel E; Gröller, M Eduard; ter Haar Romenij, Bart; Vilanova, Anna

    2010-01-01

    Insight into the dynamics of blood-flow considerably improves the understanding of the complex cardiovascular system and its pathologies. Advances in MRI technology enable acquisition of 4D blood-flow data, providing quantitative blood-flow velocities over time. The currently typical slice-by-slice analysis requires a full mental reconstruction of the unsteady blood-flow field, which is a tedious and highly challenging task, even for skilled physicians. We endeavor to alleviate this task by means of comprehensive visualization and interaction techniques. In this paper we present a framework for pre-clinical cardiovascular research, providing tools to both interactively explore the 4D blood-flow data and depict the essential blood-flow characteristics. The framework encompasses a variety of visualization styles, comprising illustrative techniques as well as improved methods from the established field of flow visualization. Each of the incorporated styles, including exploded planar reformats, flow-direction highlights, and arrow-trails, locally captures the blood-flow dynamics and may be initiated by an interactively probed vessel cross-section. Additionally, we present the results of an evaluation with domain experts, measuring the value of each of the visualization styles and related rendering parameters.

  6. Lattice BGK Simulations of the Blood Flow in Elastic Vessels

    Institute of Scientific and Technical Information of China (English)

    LU Xiao-Yang; YI Hou-Hui; CHEN Ji-Yao; FANG Hai-Ping

    2006-01-01

    @@ The lattice Boltzmann method is applied to study the flow in elastic blood vessels. The volume-flow rate increases considerably when the compliance constant of the blood vessel is below a critical value. There is a region of the compliance constant in which the average volume-flow rate is dramatically enhanced. A harmonic perturbation of the pressure does not change the behaviour of the average volume-flow rate while the harmonic wave attenuates very quickly along the tube when the resonant period is close to that of the input wave. The model, together with the simulation results, is expected to be helpful to understand the mechanism of the blood volume-flow rate related to the compliance constant of the blood vessel, especially on the dependence of the flux of human blood vessel under weather changes, which has medical significance.

  7. Blood flow controls bone vascular function and osteogenesis

    Science.gov (United States)

    Ramasamy, Saravana K.; Kusumbe, Anjali P.; Schiller, Maria; Zeuschner, Dagmar; Bixel, M. Gabriele; Milia, Carlo; Gamrekelashvili, Jaba; Limbourg, Anne; Medvinsky, Alexander; Santoro, Massimo M.; Limbourg, Florian P.; Adams, Ralf H.

    2016-01-01

    While blood vessels play important roles in bone homeostasis and repair, fundamental aspects of vascular function in the skeletal system remain poorly understood. Here we show that the long bone vasculature generates a peculiar flow pattern, which is important for proper angiogenesis. Intravital imaging reveals that vessel growth in murine long bone involves the extension and anastomotic fusion of endothelial buds. Impaired blood flow leads to defective angiogenesis and osteogenesis, and downregulation of Notch signalling in endothelial cells. In aged mice, skeletal blood flow and endothelial Notch activity are also reduced leading to decreased angiogenesis and osteogenesis, which is reverted by genetic reactivation of Notch. Blood flow and angiogenesis in aged mice are also enhanced on administration of bisphosphonate, a class of drugs frequently used for the treatment of osteoporosis. We propose that blood flow and endothelial Notch signalling are key factors controlling ageing processes in the skeletal system. PMID:27922003

  8. Mammary blood flow regulation in the nursing rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Katz, M.; Creasy, R.K.

    1984-11-01

    Cardiac output and mammary blood flow distribution prior to and after suckling were studied in 10 nursing rabbits by means of radionuclide-labeled microspheres. Suckling was followed by a 5.8% rise in cardiac output and a 20.4% rise in mammary blood flow. Determinations of intraglandular blood flow distribution have shown that there was a 43% increase in blood flow to the glands suckled from as compared to a 22.7% rise to the contralateral untouched glands and a 4.9% rise in the remainder of untouched glands. The conclusion is that a local mechanism may be involved in the regulation of mammary blood flow in the nursing rabbit.

  9. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Beaver, W. L.; Meindl, J. D.

    1976-01-01

    Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.

  10. PERFORMANCE MODELING AND ANALYSIS OF BLOOD FLOW IN ELASTIC ARTERIES

    Institute of Scientific and Technical Information of China (English)

    Anil Kumar; C.L. Varshney; G.C. Sharma

    2005-01-01

    Two different non-Newtonian models for blood flow are considered, first a simple power law model displaying shear thinning viscosity, and second a generalized Maxwell model displaying both shear thinning viscosity and oscillating flow viscous-elasticity. These models are used along with a Newtonian model to study sinusoidal flow of blood in rigid and elastic straight arteries in the presence of magnetic field. The elasticity of blood does not appear to influence its flow behavior under physiological conditions in the large arteries,purely viscous shear thinning model should be quite realistic for simulating blood flow under these conditions. On using the power law model with high shear rate for sinusoidal flow simulation in elastic arteries, the mean and amplitude of the flow rate were found to be lower for a power law fluid compared to Newtonian fluid for the same pressure gradient. The governing equations have been solved by Crank-Niclson scheme. The results are interpreted in the context of blood in the elastic arteries keeping the magnetic effects in view. For physiological flow simulation in the aorta, an increase in mean wall shear stress, but a reduction in peak wall shear stress were observed for power law model compared to a Newtonian fluid model for matched flow rate wave form. Blood flow in the presence of transverse magnetic field in an elastic artery is investigated and the influence of factors such as morphology and surface irregularity is evaluated.

  11. Dynamics of blood flow in a microfluidic ladder network

    Science.gov (United States)

    Maddala, Jeevan; Zilberman-Rudenko, Jevgenia; McCarty, Owen

    The dynamics of a complex mixture of cells and proteins, such as blood, in perturbed shear flow remains ill-defined. Microfluidics is a promising technology for improving the understanding of blood flow under complex conditions of shear; as found in stent implants and in tortuous blood vessels. We model the fluid dynamics of blood flow in a microfluidic ladder network with dimensions mimicking venules. Interaction of blood cells was modeled using multiagent framework, where cells of different diameters were treated as spheres. This model served as the basis for predicting transition regions, collision pathways, re-circulation zones and residence times of cells dependent on their diameters and device architecture. Based on these insights from the model, we were able to predict the clot formation configurations at various locations in the device. These predictions were supported by the experiments using whole blood. To facilitate platelet aggregation, the devices were coated with fibrillar collagen and tissue factor. Blood was perfused through the microfluidic device for 9 min at a physiologically relevant venous shear rate of 600 s-1. Using fluorescent microscopy, we observed flow transitions near the channel intersections and at the areas of blood flow obstruction, which promoted larger thrombus formation. This study of integrating model predictions with experimental design, aids in defining the dynamics of blood flow in microvasculature and in development of novel biomedical devices.

  12. Cerebral blood flow and metabolism during sleep.

    Science.gov (United States)

    Madsen, P L; Vorstrup, S

    1991-01-01

    A review of the current literature regarding sleep-induced changes in cerebral blood flow (CBF) and cerebral metabolic rate (CMR) is presented. Early investigations have led to the notion that dreamless sleep was characterized by global values of CBF and CMR practically at the level of wakefulness, while rapid eye movement (REM) sleep (dream sleep) was a state characterized by a dramatically increased level of CBF and possibly also of CMR. However, recent investigations firmly contradict this notion. Investigations on CBF and CMR performed during non-REM sleep, taking the effect of different levels of sleep into consideration, show that light sleep (stage II) is characterized by global levels of CBF and CMR only slightly reduced by 3-10% below the level associated with wakefulness, whereas CBF and CMR during deep sleep (stage III-IV) is dramatically reduced by 25-44%. Furthermore, recent data indicate that global levels of CBF and CMR are about the same during REM sleep as in wakefulness. On the regional level, deep sleep seems to be associated with a uniform decrease in regional CBF and CMR. Investigations concerning regional CBF and CMR during REM sleep are few but data from recent investigations seem to identify site-specific changes in regional CBF and CMR during REM sleep. CBF and CMR are reflections of cerebral synaptic activity and the magnitude of reduction in these variables associated with deep sleep indicates that overall cerebral synaptic activity is reduced to approximately one-half the level associated with wakefulness, while cerebral synaptic activity levels during REM sleep are similar to wakefulness. However, even though the new understanding of CBF and CMR during sleep provides significant and important information of the brain's mode of working during sleep, it does not at its current state identify the physiological processes involved in sleep or the physiological role of sleep.

  13. Regional patterns of cortical blood flow distinguish extraverts from introverts

    OpenAIRE

    Stenberg, Georg; Risberg, Jarl; Warkentin, S.; Rosén, Ingmar

    1990-01-01

    Eysenck's hypothesis of higher cortical arousal in introverts was examined using regional cerebral blood flow measurement in 37 healthy subjects . The measurement was made at rest, using the133Xe-inhalation method. Estimates of gray matter flow were obtained for 32 brain regions. There was no significant evidence of personality differences in general arousal, as measured by the mean flow level, averaged over all regions. There were, however, regional differences. An overall test of the blood ...

  14. Quantification of complex blood flow using real-time in vivo vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Haugaard, Per;

    2010-01-01

    A quantitative method for distinguishing complex from non-complex flow patterns in ultrasound is presented. A new commercial BK Medical ultrasound scanner uses the Transverse Oscillation vector flow technique for visualising flow patterns in real-time. In vivo vector flow data of the blood flow...

  15. On the flow dependency of the electrical conductivity of blood

    NARCIS (Netherlands)

    Hoetink, AE; Faes, TJC; Visser, KR; Heethaar, RM

    2004-01-01

    Experiments presented in the literature show that the electrical conductivity of flowing blood depends on flow velocity. The aim of this study is to extend the Maxwell-Fricke theory, developed for a dilute suspension of ellipsoidal particles in an electrolyte, to explain this flow dependency of the

  16. ANALYSIS OF PULSATILE BLOOD FLOW IN AXIALLY MOVING ARTERIES

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In order to study motional properties of pulsatile blood flow in axially moving arteries, the authors derived some expressions of the pulsatile blood flow from the basic equations of motion for blood and vascular walls, including an axial blood velocity equation, a flow rate equation and a wall shear stress equation, which described not only the overall axial movement of the arteries but also the elastic properties of the vascular walls, discussed the effects of the arterial wall elasticity on the wall shear stress in coronary arteries in terms of these expressions, and analyzed changes of motional properties of pulsatile blood flow between an elastic arterial tube model and a rigid tube model. The results proved the inference by J.E. Moore Jr. et al. (1994) that the axial movement of arteries be as important in determining coronary artery hemodynamics as the elastic property of the vascular wall.

  17. The effect of hyperosmotic solutions on the hepatic blood flow

    DEFF Research Database (Denmark)

    Winkler, K; Henriksen, Jens Henrik; Tygstrup, N

    1993-01-01

    The present study was undertaken in order to measure the effect of hyperosmotic solutions on portal and hepatic blood flow. In five anaesthetized pigs without arterial blood supply to the liver, portal blood flow rate was measured (electromagnetic flowmeter) during 5 min lasting intravenous...... infusions of hyperosmotic galactose (50%, 84-100 ml) and mannitol (25%, 100 ml), with physiological saline (100 ml) as control. Portal blood flow increased to a peak value of (39% [P = 0.06] galactose and 37%, [P = 0.06], mannitol) soon after stop of the hyperosmotic infusion. For galactose the change ended...... somewhat earlier than for mannitol. Saline induced a minor increase (15%). Similarly, increments of, on average, 144% of the hepatic blood flow rate was seen in six patients with cirrhosis, following infusion of hyperosmotic galactose, the increase being more pronounced than in the pigs. The causes...

  18. Mesenteric, coeliac and splanchnic blood flow in humans during exercise

    DEFF Research Database (Denmark)

    Perko, M J; Nielsen, H B; Skak, C;

    1998-01-01

    1. Exercise reduces splanchnic blood flow, but the mesenteric contribution to this response is uncertain. 2. In nineteen humans, superior mesenteric and coeliac artery flows were determined by duplex ultrasonography during fasting and postprandial submaximal cycling and compared with the splanchnic...... blood flow as assessed by the Indocyanine Green dye-elimination technique. 3. Cycling increased arterial pressure, heart rate and cardiac output, while it reduced total vascular resistance. These responses were not altered in the postprandial state. During fasting, cycling increased mesenteric, coeliac...... and splanchnic resistances by 76, 165 and 126 %, respectively, and it reduced corresponding blood flows by 32, 50 and 43 % (by 0.18 +/- 0.04, 0.42 +/- 0.03 and 0.60 +/- 0.04 l min-1). Postprandially, mesenteric and splanchnic vascular resistances decreased, thereby elevating regional blood flow, while...

  19. Effects of non Newtonian spiral blood flow through arterial stenosis

    Science.gov (United States)

    Hasan, Md. Mahmudul; Maruf, Mahbub Alam; Ali, Mohammad

    2016-07-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system. A numerical investigation is carried out to analyze the effect of spiral blood flow through an axisymmetric three dimensional artery having 75% stenosis at the center. Blood is assumed as a Non-Newtonian fluid. Standard k-ω model is used for the simulation with the Reynolds number of 1000. A parabolic velocity profile with spiral flow is used as inlet boundary condition. The peak values of all velocity components are found just after stenosis. But total pressure gradually decreases at downstream. Spiral flow of blood has significant effects on tangential component of velocity. However, the effect is mild for radial and axial velocity components. The peak value of wall shear stress is at the stenosis zone and decreases rapidly in downstream. The effect of spiral flow is significant for turbulent kinetic energy. Detailed investigation and relevant pathological issues are delineated throughout the paper.

  20. Spontaneous oscillations of capillary blood flow in artificial microvascular networks.

    Science.gov (United States)

    Forouzan, Omid; Yang, Xiaoxi; Sosa, Jose M; Burns, Jennie M; Shevkoplyas, Sergey S

    2012-09-01

    Previous computational studies have suggested that the capillary blood flow oscillations frequently observed in vivo can originate spontaneously from the non-linear rheological properties of blood, without any regulatory input. Testing this hypothesis definitively in experiments involving real microvasculature has been difficult because in vivo the blood flow in capillaries is always actively controlled by the host. The objective of this study was to test the hypothesis experimentally and to investigate the relative contribution of different blood cells to the capillary blood flow dynamics under static boundary conditions and in complete isolation from the active regulatory mechanisms mediated by the blood vessels in vivo. To accomplish this objective, we passed whole blood and re-constituted blood samples (purified red blood cells suspended in buffer or in autologous plasma) through an artificial microvascular network (AMVN) comprising completely inert, microfabricated vessels with the architecture inspired by the real microvasculature. We found that the flow of blood in capillaries of the AMVN indeed oscillates with characteristic frequencies in the range of 0-0.6 Hz, which is in a very good agreement with previous computational studies and in vivo observations. We also found that the traffic of leukocytes through the network (typically neglected in computational modeling) plays an important role in generating the oscillations. This study represents the key piece of experimental evidence in support of the hypothesis that spontaneous, self-sustained oscillations of capillary blood flow can be generated solely by the non-linear rheological properties of blood flowing through microvascular networks, and provides an insight into the mechanism of this fundamentally important microcirculatory phenomenon.

  1. Modified Beer-Lambert law for blood flow

    Science.gov (United States)

    Baker, Wesley B.; Parthasarathy, Ashwin B.; Busch, David R.; Mesquita, Rickson C.; Greenberg, Joel H.; Yodh, A. G.

    2015-03-01

    The modified Beer-Lambert law is among the most widely used approaches for analysis of near-infrared spectroscopy (NIRS) reflectance signals for measurements of tissue blood volume and oxygenation. Briefly, the modified Beer-Lambert paradigm is a scheme to derive changes in tissue optical properties based on continuous-wave (CW) diffuse optical intensity measurements. In its simplest form, the scheme relates differential changes in light transmission (in any geometry) to differential changes in tissue absorption. Here we extend this paradigm to the measurement of tissue blood flow by diffuse correlation spectroscopy (DCS). In the new approach, differential changes of the intensity temporal auto-correlation function at a single delay-time are related to differential changes in blood flow. The key theoretical results for measurement of blood flow changes in any tissue geometry are derived, and we demonstrate the new method to monitor cerebral blood flow in a pig under conditions wherein the semi-infinite geometry approximation is fairly good. Specifically, the drug dinitrophenol was injected in the pig to induce a gradual 200% increase in cerebral blood flow, as measured with MRI velocity flow mapping and by DCS. The modified Beer-Lambert law for flow accurately recovered these flow changes using only a single delay-time in the intensity auto-correlation function curve. The scheme offers increased DCS measurement speed of blood flow. Further, the same techniques using the modified Beer-Lambert law to filter out superficial tissue effects in NIRS measurements of deep tissues can be applied to the DCS modified Beer-Lambert law for blood flow monitoring of deep tissues.

  2. AN ANALYSIS MODEL OF PULSATILE BLOOD FLOW IN ARTERIES

    Institute of Scientific and Technical Information of China (English)

    LIUZhao-rong; XUGang; CHENYong; TENGZhong0=zhao; QINKai-rong

    2003-01-01

    Blood flow in artery was treated as the flow under equilibriums state(the steady flow under mean pressure)combined with the periodically small pulsatile flow.Using vascular strain energy function advanced by Fung,the vascular stress-strain relationship under equilibrium state was analyzed and the circumferential and axial elastic moduli were deduced that are expressed while the arterial strains around the equilibrium state are relatively small,so that the equations of vesse wall motion under the pulsatile pressure could be established here.Through solving both the vessel equations and the linear Navier-Stokes equations,the analytic expressions of the blood flow velocities and the vascular displacements were obtained.The influence of the difference between vascular circumferentia and axial elasticities on pulsatile blood flow and vascular motion was discussed in details.

  3. AN ANALYSIS MODEL OF PULSATILE BLOOD FLOW IN ARTERIES

    Institute of Scientific and Technical Information of China (English)

    柳兆荣; 徐刚; 陈泳; 滕忠照; 覃开蓉

    2003-01-01

    Blood flow in artery was treated as the flow under equilibrium state ( the steady flow under mean pressure ) combined with the periodically small pulsatile flow. Using vascular strain energy function advanced by Fung, the vascular stress-strain relationship under equilibrium state was analyzed and the circumferential and axial elastic moduli were deduced that are expressed while the arterial strains around the equilibrium state are relatively small, so that the equations of vessel wall motion under the pulsatile pressure could be established here. Through solving both the vessel equations and the linear NavierStokes equations, the analytic expressions of the blood flow velocities and the vascular displacements were obtained. The influence of the difference between vascular circumferential and axial elasticities on pulsatile blood flow and vascular motion was discussed in details.

  4. Arterial secondary blood flow patterns visualized with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Hansen, Jens Munk

    2011-01-01

    This study presents the first quantification and visualisation of secondary flow patterns with vector flow ultrasound. The first commercial implementation of the vector flow method Transverse Oscillation was used to obtain in-vivo, 2D vector fields in real-time. The hypothesis of this study...

  5. Regulation of exercise blood flow: Role of free radicals.

    Science.gov (United States)

    Trinity, Joel D; Broxterman, Ryan M; Richardson, Russell S

    2016-09-01

    During exercise, oxygen and nutrient rich blood must be delivered to the active skeletal muscle, heart, skin, and brain through the complex and highly regulated integration of central and peripheral hemodynamic factors. Indeed, even minor alterations in blood flow to these organs have profound consequences on exercise capacity by modifying the development of fatigue. Therefore, the fine-tuning of blood flow is critical for optimal physical performance. At the level of the peripheral circulation, blood flow is regulated by a balance between the mechanisms responsible for vasodilation and vasoconstriction. Once thought of as toxic by-products of in vivo chemistry, free radicals are now recognized as important signaling molecules that exert potent vasoactive responses that are dependent upon the underlying balance between oxidation-reduction reactions or redox balance. Under normal healthy conditions with low levels of oxidative stress, free radicals promote vasodilation, which is attenuated with exogenous antioxidant administration. Conversely, with advancing age and disease where background oxidative stress is elevated, an exercise-induced increase in free radicals can further shift the redox balance to a pro-oxidant state, impairing vasodilation and attenuating blood flow. Under these conditions, exogenous antioxidants improve vasodilatory capacity and augment blood flow by restoring an "optimal" redox balance. Interestingly, while the active skeletal muscle, heart, skin, and brain all have unique functions during exercise, the mechanisms by which free radicals contribute to the regulation of blood flow is remarkably preserved across each of these varied target organs.

  6. Large-Eddy simulation of pulsatile blood flow.

    Science.gov (United States)

    Paul, Manosh C; Mamun Molla, Md; Roditi, Giles

    2009-01-01

    Large-Eddy simulation (LES) is performed to study pulsatile blood flow through a 3D model of arterial stenosis. The model is chosen as a simple channel with a biological type stenosis formed on the top wall. A sinusoidal non-additive type pulsation is assumed at the inlet of the model to generate time dependent oscillating flow in the channel and the Reynolds number of 1200, based on the channel height and the bulk velocity, is chosen in the simulations. We investigate in detail the transition-to-turbulent phenomena of the non-additive pulsatile blood flow downstream of the stenosis. Results show that the high level of flow recirculation associated with complex patterns of transient blood flow have a significant contribution to the generation of the turbulent fluctuations found in the post-stenosis region. The importance of using LES in modelling pulsatile blood flow is also assessed in the paper through the prediction of its sub-grid scale contributions. In addition, some important results of the flow physics are achieved from the simulations, these are presented in the paper in terms of blood flow velocity, pressure distribution, vortices, shear stress, turbulent fluctuations and energy spectra, along with their importance to the relevant medical pathophysiology.

  7. Reduced myocardial blood flow in acute and chronic digitalization.

    Science.gov (United States)

    Steiness, E; Bille-Brahe, N E; Hansen, J F; Lomholt, N; Ring-Larsen, H

    1978-07-01

    The myocardial blood flow was measured by the 133Xenon disappearance curve from the left ventricular wall following an injection of 133Xenon in the left coronary artery in 8 dogs without digoxin pretreatment and in 8 chronically digitalized dogs. The myocardial blood flow was significantly less (30%) in the digitalized dogs than in the dogs without pretreatment. In the digitalized dogs as well as in those without pretreatment an intravenous injection of digoxin resulted in a further significant decrease of the myocardial blood flow of about 20% and a significant increase of the coronary vascular resistance. The reduced myocardial blood flow both during acute and chronic digitalization is beleived to be of clinical importance.

  8. Skeletal Blood Flow in Bone Repair and Maintenance

    Institute of Scientific and Technical Information of China (English)

    Ryan E.Tomlinson; Matthew J.Silva

    2013-01-01

    Bone is a highly vascularized tissue, although this aspect of bone is often overlooked. In this article, the importance of blood flow in bone repair and regeneration will be reviewed. First, the skeletal vascular anato-my, with an emphasis on long bones, the distinct mechanisms for vascularizing bone tissue, and methods for remodeling existing vasculature are discussed. Next, techniques for quantifying bone blood flow are briefly summarized. Finally, the body of experimental work that demonstrates the role of bone blood flow in fracture healing, distraction osteogenesis, osteoporosis, disuse osteopenia, and bone grafting is examined. These results illustrate that adequate bone blood flow is an important clinical consideration, particularly during bone regeneration and in at-risk patient groups.

  9. Study Links Stuttering to Less Blood Flow in Brain

    Science.gov (United States)

    ... medlineplus.gov/news/fullstory_162922.html Study Links Stuttering to Less Blood Flow in Brain The more ... to speech may put people at risk for stuttering, a small study suggests. There are also signs ...

  10. Current Imaging Modalities for assessing Ocular Blood Flow in Glaucoma

    OpenAIRE

    Mohindroo, Chirayu; Ichhpujani, Parul; Kumar, Suresh

    2016-01-01

    Glaucoma may be caused by an interplay of elevated intraocular pressure (IOP), vascular, genetic, anatomical, brain, and immune factors. The direct assessment of ocular hemodynam-ics offers promise for glaucoma detection, differentiation, and possibly new treatment modalities. All the methods currently in use to measure ocular blood flow have inherent limitations and measure different aspects of ocular blood flow. This review article attempts to provide detailed information on ocular perfu-si...

  11. Salt-gland secretion and blood flow in the goose.

    Science.gov (United States)

    Hanwell, A; Linzell, J L; Peaker, M

    1971-03-01

    1. Salt-gland blood flow in the domestic goose has been measured using a combination of Sapirstein's indicator fractionation technique for organ blood flow and Fegler's thermodilution method for cardiac output.2. Nasal salt secretion was induced by giving 0.5 M-NaCl or 0.154 M-NaCl I.V. or by giving artificial sea water by stomach tube into the proventriculus.3. During secretion, salt-gland blood flow increased from 82.7 +/- 21.9 ml./100 g tissue. min to as high as 2179 ml./100 g. min (mean 1209 +/- 140).4. The rate of secretion in response to salt loading was very variable and was not correlated with the rate of blood flow.5. From the data obtained, it could be calculated that the median values for the percentage extraction of ions from the arterial plasma were Na 15%, K 35%, Cl 21% and water 5.8%.6. Atropine abolished secretion but not the increase in blood flow produced by salt loading.7. Unilateral complete denervation abolished secretion from and the increase in blood flow through the operated but not the control gland.8. Anaesthesia, induced by pentobarbitone sodium, almost completely blocked secretion and the increase in blood flow in the salt-gland in response to salt loading.9. In geese given 0.5 or 0.154 M-NaCl I.V. a positive, significant correlation was found between the total amount of nasal secretion collected over 30 min and the concentrations of Na and Cl in the nasal fluid. However, when the time course of secretion was followed in any one bird, the rate of secretion was inversely related to the concentrations of Na and Cl.10. Harderian gland blood flow was not affected by salt loading.

  12. Experimental comparison of mammalian and avian blood flow in microchannels

    Science.gov (United States)

    Fink, Kathryn; Liepmann, Dorian

    2015-11-01

    The non-Newtonian, shear rate dependent behavior of blood in microchannel fluid dynamics has been studied for nearly a century, with a significant focus on the characteristics of human blood. However, for over 200 years biologists have noted significant differences in red blood cell characteristics across vertebrate species, with particularly drastic differences in cell size and shape between mammals and non-mammalian classes. We present an experimental analysis of flow in long microchannels for several varieties of mammalian and avian blood, across a range of hematocrits, channel diameters, and flow rates. Correlation of shear rate and viscosity is compared to existing constitutive equations for human blood to further quantify the importance of red blood cell characteristics. Ongoing experimental results are made available in an online database for reference or collaboration. K.F. acknowledges funding from the ARCS Foundation and an NSF Graduate Research Fellowship through NSF Grant DGE 1106400.

  13. APPLICATION OF THE THEORY OF INTERACTING CONTINUA TO BLOOD FLOW

    Energy Technology Data Exchange (ETDEWEB)

    Massoudi, Mehrdad; Kim, Jeongho; Hund, Samuel J.; Antaki, James F.

    2011-01-01

    Micro-scale investigations of the flow and deformation of blood and its formed elements have been studied for many years. Early in vitro investigations in the rotational viscometers or small glass tubes revealed important rheological properties such as the reduced blood apparent viscosity, Fahraeus effect and Fahraeus-Lindqvist effect [1], exhibiting the nonhomogeneous property of blood in microcirculation. We have applied Mixture Theory, also known as Theory of Interacting Continua, to study and model this property of blood [2, 3]. This approach holds great promise for predicting the trafficking of RBCs in micro-scale flows (such as the depletion layer near the wall), and other unique hemorheological phenomena relevant to blood trauma. The blood is assumed to be composed of an RBC component modeled as a nonlinear fluid, suspended in plasma, modeled as a linearly viscous fluid.

  14. Blood flow changes coincide with cellular rearrangements during blood vessel pruning in zebrafish embryos.

    Directory of Open Access Journals (Sweden)

    Eva Kochhan

    Full Text Available After the initial formation of a highly branched vascular plexus, blood vessel pruning generates a hierarchically structured network with improved flow characteristics. We report here on the cellular events that occur during the pruning of a defined blood vessel in the eye of developing zebrafish embryos. Time-lapse imaging reveals that the connection of a new blood vessel sprout with a previously perfused multicellular endothelial tube leads to the formation of a branched, Y-shaped structure. Subsequently, endothelial cells in parts of the previously perfused branch rearrange from a multicellular into a unicellular tube, followed by blood vessel detachment. This process is accompanied by endothelial cell death. Finally, we show that differences in blood flow between neighboring vessels are important for the completion of the pruning process. Our data suggest that flow induced changes in tubular architecture ensure proper blood vessel pruning.

  15. Functional Doppler optical coherence tomography for cortical blood flow imaging

    Science.gov (United States)

    Yu, Lingfeng; Liu, Gangjun; Nguyen, Elaine; Choi, Bernard; Chen, Zhongping

    2010-02-01

    Optical methods have been widely used in basic neuroscience research to study the cerebral blood flow dynamics in order to overcome the low spatial resolution associated with magnetic resonance imaging and positron emission tomography. Although laser Doppler imaging and laser speckle imaging can map out en face cortical hemodynamics and columns, depth resolution is not available. Two-photon microscopy has been used for mapping cortical activity. However, flow measurement requires fluorescent dye injection, which can be problematic. The noninvasive and high resolution tomographic capabilities of optical coherence tomography make it a promising technique for mapping depth resolved cortical blood flow. Here, we present a functional Doppler optical coherence tomography (OCT) imaging modality for quantitative evaluation of cortical blood flow in a mouse model. Fast, repeated, Doppler OCT scans across a vessel of interest were performed to record flow dynamic information with a high temporal resolution of the cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time, thereby providing complementary temporal flow information to the spatially distributed flow information of Doppler OCT. The proposed functional Doppler OCT imaging modality can be used to diagnose vessel stenosis/blockage or monitor blood flow changes due to pharmacological agents/neuronal activities. Non-invasive in-vivo mice experiments were performed to verify the capabilities of function Doppler OCT.

  16. Blood flow and microdialysis in the human femoral head

    DEFF Research Database (Denmark)

    Bøgehøj, Morten; Emmeluth, Claus; Overgaard, Søren

    2007-01-01

    BACKGROUND: If it would be possible to detect lack of flow and/or the development of ischemia in bone, we might have a way of predicting whether a broken bone will heal. We established microdialysis (MD) and laser Doppler (LD) flow measurement in the human femoral head in order to be able to detect...... ischemia and measure changes in blood flow. MATERIAL AND METHODS: In 9 patients undergoing total hip arthroplasty for primary osteoarthrosis, two MD catheters were inserted into the femoral head through two drill holes after the blood flow had been visualized by LD. Then primary samples were collected...... detected within 2 h of cessation of blood flow in most patients....

  17. Coronary Flow Velocity Reserve Assessed by Transthoracic Doppler

    DEFF Research Database (Denmark)

    Michelsen, Marie M; Pena, Adam; Mygind, Naja D;

    2016-01-01

    of the left anterior descending coronary artery in two-dimensional color Doppler mode, and (4) gradual, consistent increases of characteristic, well-defined flow velocity curves in pulsed-wave mode. RESULTS: The mean age (SD) was 62.1 ± 9.7 years. On the basis of the evaluations, patients were divided...

  18. Establishing the diffuse correlation spectroscopy signal relationship with blood flow.

    Science.gov (United States)

    Boas, David A; Sakadžić, Sava; Selb, Juliette; Farzam, Parisa; Franceschini, Maria Angela; Carp, Stefan A

    2016-07-01

    Diffuse correlation spectroscopy (DCS) measurements of blood flow rely on the sensitivity of the temporal autocorrelation function of diffusively scattered light to red blood cell (RBC) mean square displacement (MSD). For RBCs flowing with convective velocity [Formula: see text], the autocorrelation is expected to decay exponentially with [Formula: see text], where [Formula: see text] is the delay time. RBCs also experience shear-induced diffusion with a diffusion coefficient [Formula: see text] and an MSD of [Formula: see text]. Surprisingly, experimental data primarily reflect diffusive behavior. To provide quantitative estimates of the relative contributions of convective and diffusive movements, we performed Monte Carlo simulations of light scattering through tissue of varying vessel densities. We assumed laminar vessel flow profiles and accounted for shear-induced diffusion effects. In agreement with experimental data, we found that diffusive motion dominates the correlation decay for typical DCS measurement parameters. Furthermore, our model offers a quantitative relationship between the RBC diffusion coefficient and absolute tissue blood flow. We thus offer, for the first time, theoretical support for the empirically accepted ability of the DCS blood flow index ([Formula: see text]) to quantify tissue perfusion. We find [Formula: see text] to be linearly proportional to blood flow, but with a proportionality modulated by the hemoglobin concentration and the average blood vessel diameter.

  19. Stochastic modeling for magnetic resonance quantification of myocardial blood flow

    Science.gov (United States)

    Seethamraju, Ravi T.; Muehling, Olaf; Panse, Prasad M.; Wilke, Norbert M.; Jerosch-Herold, Michael

    2000-10-01

    Quantification of myocardial blood flow is useful for determining the functional severity of coronary artery lesions. With advances in MR imaging it has become possible to assess myocardial perfusion and blood flow in a non-invasive manner by rapid serial imaging following injection of contrast agent. To date most approaches reported in the literature relied mostly on deriving relative indices of myocardial perfusion directly from the measured signal intensity curves. The central volume principle on the other hand states that it is possible to derive absolute myocardial blood flow from the tissue impulse response. Because of the sensitivity involved in deconvolution due to noise in measured data, conventional methods are sub-optimal, hence, we propose to use stochastic time series modeling techniques like ARMA to obtain a robust impulse response estimate. It is shown that these methods when applied for the optical estimation of the transfer function give accurate estimates of myocardial blood flow. The most significant advantage of this approach, compared with compartmental tracer kinetic models, is the use of a minimum set of prior assumptions on data. The bottleneck in assessing myocardial blood flow, does not lie in the MRI acquisition, but rather in the effort or time for post processing. It is anticipated that the very limited requirements for user input and interaction will be of significant advantage for the clinical application of these methods. The proposed methods are validated by comparison with mean blood flow measurements obtained from radio-isotope labeled microspheres.

  20. Hepatic and intestinal blood flow following thermal injury

    Energy Technology Data Exchange (ETDEWEB)

    Carter, E.A.; Tompkins, R.G.; Burke, J.F.

    1988-07-01

    Because cardiac output decreases after burn injuries, investigators have assumed, based upon dye clearance techniques, that hepatic and intestinal blood flow are also decreased following these injuries. Blood flow to the liver, stomach, small intestine, and kidney was determined by the uptake of 201thallium and 125I-labeled fatty acid (para-125I-phenyl-3-methyl pentanoic acid) in a 20% body surface area scald injury that also included plasma volume replacement resuscitation. Uptake of these radioisotopes was determined 15 minutes, 18 hours, and 72 hours after injury. The uptake of the 201thallium and 125I-labeled fatty acid by the gastrointestinal tissues was not statistically different at any of the time periods after comparison of the injured and control (sham-treated) animals. 201Thallium uptake by the kidney was significantly diminished 15 minutes after the burn injury (P less than 0.01). Based on these blood flow measurement techniques, the data suggest that the 20% body surface area scald injury did not alter blood flow to the liver or gastrointestinal tract within the initial 72 hours after the burn injury even though a decrease in renal blood flow was easily detected. These results suggest that the dysfunction of the gastrointestinal system or hepatic system observed after an acute burn injury is not simply the result of hypovolemic shock, which reduces both renal and mesenteric blood flow. These gastrointestinal and hepatic alterations may be related to a factor or factors other than intestinal ischemia.

  1. Radiohalogenated thienylethylamine derivatives for evaluating local cerebral blood flow

    Science.gov (United States)

    Goodman, Mark M.; Knapp, Jr., Furn F.

    1990-01-01

    Radiopharmaceuticals useful in brain imaging comprising radiohalogenated thienylethylamine derivatives. The compounds are 5-halo-thiophene-2-isopropyl amines able to cross the blood-brain barrier and be retained for a sufficient length of time to allow the evaluation or regional blood flow by radioimaging of the brain.

  2. Microvascular blood flow resistance: Role of red blood cell migration and dispersion.

    Science.gov (United States)

    Katanov, Dinar; Gompper, Gerhard; Fedosov, Dmitry A

    2015-05-01

    Microvascular blood flow resistance has a strong impact on cardiovascular function and tissue perfusion. The flow resistance in microcirculation is governed by flow behavior of blood through a complex network of vessels, where the distribution of red blood cells across vessel cross-sections may be significantly distorted at vessel bifurcations and junctions. In this paper, the development of blood flow and its resistance starting from a dispersed configuration of red blood cells is investigated in simulations for different hematocrit levels, flow rates, vessel diameters, and aggregation interactions between red blood cells. Initially dispersed red blood cells migrate toward the vessel center leading to the formation of a cell-free layer near the wall and to a decrease of the flow resistance. The development of cell-free layer appears to be nearly universal when scaled with a characteristic shear rate of the flow. The universality allows an estimation of the length of a vessel required for full flow development, lc ≲ 25D, for vessel diameters in the range 10 μm red blood cell dispersion at vessel bifurcations and junctions on the flow resistance may be significant in vessels which are shorter or comparable to the length lc. Aggregation interactions between red blood cells generally lead to a reduction of blood flow resistance. The simulations are performed using the same viscosity for both external and internal fluids and the RBC membrane viscosity is not considered; however, we discuss how the viscosity contrast may affect the results. Finally, we develop a simple theoretical model which is able to describe the converged cell-free-layer thickness at steady-state flow with respect to flow rate. The model is based on the balance between a lift force on red blood cells due to cell-wall hydrodynamic interactions and shear-induced effective pressure due to cell-cell interactions in flow. We expect that these results can also be used to better understand the flow

  3. Ultrafast Ultrasound Imaging of Ocular Anatomy and Blood Flow

    Science.gov (United States)

    Urs, Raksha; Ketterling, Jeffrey A.; Silverman, Ronald H.

    2016-01-01

    Purpose Ophthalmic ultrasound imaging is currently performed with mechanically scanned single-element probes. These probes have limited capabilities overall and lack the ability to image blood flow. Linear-array systems are able to detect blood flow, but these systems exceed ophthalmic acoustic intensity safety guidelines. Our aim was to implement and evaluate a new linear-array–based technology, compound coherent plane-wave ultrasound, which offers ultrafast imaging and depiction of blood flow at safe acoustic intensity levels. Methods We compared acoustic intensity generated by a 128-element, 18-MHz linear array operated in conventionally focused and plane-wave modes and characterized signal-to-noise ratio (SNR) and lateral resolution. We developed plane-wave B-mode, real-time color-flow, and high-resolution depiction of slow flow in postprocessed data collected continuously at a rate of 20,000 frames/s. We acquired in vivo images of the posterior pole of the eye by compounding plane-wave images acquired over ±10° and produced images depicting orbital and choroidal blood flow. Results With the array operated conventionally, Doppler modes exceeded Food and Drug Administration safety guidelines, but plane-wave modalities were well within guidelines. Plane-wave data allowed generation of high-quality compound B-mode images, with SNR increasing with the number of compounded frames. Real-time color-flow Doppler readily visualized orbital blood flow. Postprocessing of continuously acquired data blocks of 1.6-second duration allowed high-resolution depiction of orbital and choroidal flow over the cardiac cycle. Conclusions Newly developed high-frequency linear arrays in combination with plane-wave techniques present opportunities for the evaluation of ocular anatomy and blood flow, as well as visualization and analysis of other transient phenomena such as vessel wall motion over the cardiac cycle and saccade-induced vitreous motion. PMID:27428169

  4. Femoral Blood Flow and Cardiac Output During Blood Flow Restricted Leg Press Exercise

    Science.gov (United States)

    Everett, M. E.; Hackney, K.; Ploutz-Snyder, L.

    2011-01-01

    Low load blood flow restricted resistance exercise (LBFR) causes muscle hypertrophy that may be stimulated by the local ischemic environment created by the cuff pressure. However, local blood flow (BF) during such exercise is not well understood. PURPOSE: To characterize femoral artery BF and cardiac output (CO) during leg press exercise (LP) performed at a high load (HL) and low load (LL) with different levels of cuff pressure. METHODS: Eleven subjects (men/women 4/7, age 31.4+/-12.8 y, weight 68.9+/-13.2 kg, mean+/-SD) performed 3 sets of supine left LP to fatigue with 90 s of rest in 4 conditions: HL (%1-RM/cuff pressure: 80%/0); LL (20%/0); LBFR(sub DBP) (20%/1.3 x diastolic blood pressure, BP); LBFR(sub SBP) (20%/1.3 x supine systolic BP). The cuff remained inflated throughout the LBFR exercise sessions. Artery diameter, velocity time integral (VTI), and stroke volume (SV) were measured using Doppler ultrasound at rest and immediately after each set of exercise. Heart rate (HR) was monitored using a 3-lead ECG. BF was calculated as VTI x vessel cross-sectional area. CO was calculated as HR x SV. The data obtained after each set of exercise were averaged and used for analyses. Multi-level modeling was used to determine the effect of exercise condition on dependent variables. Statistical significance was set a priori at p LL (9.92+/-0.82 cm3) > LBFR(sub dBP)(6.47+/-0.79 cm3) > LBFR(sub SBP) (3.51+/-0.59 cm3). Blunted exercise induced increases occurred in HR, SV, and CO after LBFR compared to HL and LL. HR increased 45% after HL and LL and 28% after LBFR (p<0.05), but SV increased (p<0.05) only after HL. Consequently, the increase (p<0.05) in CO was greater in HL and LL (approximately 3 L/min) than in LBFR (approximately 1 L/min). CONCLUSION: BF during LBFR(sub SBP) was 1/3 of that observed in LL, which supports the hypothesis that local ischemia stimulates the LBFR hypertrophic response. As the cuff did not compress the artery, the ischemia may have occurred

  5. Marine Forces Reserve: Accelerating Knowledge Flow through Asynchronous Learning Technologies

    Science.gov (United States)

    2014-12-19

    pedagogic techniques that are infeasible in the classroom , and they suggest that in some respects technologically intermediated learning can be even better...frameworks and technologies to examine I-I knowledge flows, and from the practitioner perspective, we bring to bear deep inside knowledge of the focal...ASYNCHRONOUS LEARNING TECHNOLOGIES by Mark Nissen, Robert McGuiness and Anthony Davis December 2014 Further distribution of all or part of this

  6. Evaluation of blood reservation and use for caesarean sections in a tertiary maternity unit in south western Nigeria

    Directory of Open Access Journals (Sweden)

    Oshodi Yussuf A

    2010-09-01

    Full Text Available Abstract Background Haemorrhage from obstetric causes is the most common cause of maternal mortality in the developing world. Prevention of mortality from haemorrhage will necessarily involve prompt blood transfusions among other life saving measures. There are however limited stocks of fresh or stored blood in many health care facilities in Sub Saharan Africa. Caesarean section has been identified as a common indication for blood transfusion in obstetrics practice and its performance is often delayed by non availability of blood in our centre. An evaluation of blood reservation and use at caesarean sections in a tertiary maternity unit in Lagos, south western Nigeria should therefore assist in formulating the most rational blood transfusion policies. Methods Case records of 327 patients who had elective and emergency caesarian sections at the Lagos State University Teaching Hospital between 1st October and 31st December 2007 were reviewed. Data pertaining to age, parity, booking status, type and indication for Caesarean section, pre- and post-operative packed cell volume, blood loss at surgery, units of blood reserved in the blood bank, unit(s of blood transfused and duration of hospital stay was extracted and the data analysed. Results There were 1056 deliveries out of which 327 (31% were by Caesarean section. During the study period, a total of 654 units of blood were reserved in the blood bank and subsequently made available in theatre. Out of this number, only 89 (13.6% were transfused to 41 patients. Amongst those transfused, twenty-six (54% were booked and 31 (75.6% had primary caesarian section. About 81% of those transfused had emergency caesarean section. The most common indication for surgery among those transfused were placenta praevia (9 patients with 21 units of blood and cephalo-pelvic disproportion (8 patients with 13 units. Conclusion Even though a large number of units of blood was reserved and made available in the theatre at

  7. Methods for measurement of cerebral blood flow in man

    DEFF Research Database (Denmark)

    Lassen, N A

    1976-01-01

    A survey of the currently available methods for the measurement of cerebral blood flow in man is given. Many of the clinically important brain diseases such as tumors, stroke, brain trauma or epilepsy entail focal or regional flow alterations. Therefore a special emphasis is placed on methods all...

  8. Blood Flow through an Open-Celled Foam

    Science.gov (United States)

    Ortega, Jason; Maitland, Duncan

    2011-11-01

    The Hazen-Dupuit-Darcy (HDD) equation is commonly used in engineering applications to model the pressure gradient of flow through a porous media. One major advantage of this equation is that it simplifies the complex geometric details of the porous media into two coefficients: the permeability, K, and form factor, C. However through this simplification, the flow details within the porous media are no longer accessible, making it difficult to study the phenomena that contribute to changes in K and C due to clotting of blood flow. To obtain a more detailed understanding of blood flow through a porous media, a direct assessment of the complex interstitial geometry and flow is required. In this study, we solve the Navier-Stokes equations for Newtonian and non-Newtonian blood flow through an open-celled foam geometry obtained from a micro-CT scan. The nominal strut size of the foam sample is of O(10e-5) m and the corresponding Reynolds number based upon this length ranges up to O(10). Fitting the pressure gradient vs. Darcy velocity data with the HDD equation demonstrates that both viscous and inertial forces play an important role in the flow through the foam at these Reynolds numbers. Recirculation zones are observed to form in the wake of the pore struts, producing regions of flow characterized by both low shear rates and long fluid residence times, factors of which have been shown in previous studies to promote blood clotting.

  9. Ultrasonic Imaging of Hemodynamic Force in Carotid Blood Flow

    Science.gov (United States)

    Nitta, N.; Homma, K.

    Hemodynamic forces including blood pressure and shear stress affect vulnerable plaque rupture in arteriosclerosis and biochemical activation of endothelium such as NO production. In this study, a method for estimating and imaging shear stress and pressure gradient distributions in blood vessel as the hemodynamic force based on viscosity estimation is presented. Feasibility of this method was investigated by applying to human carotid blood flow. Estimated results of shear stress and pressure gradient distributions coincide with the ideal distributions obtained by numerical simulation and flow-phantom experiment.

  10. CHARACTERIZATION OF RENAL BLOOD FLOW REGULATION BASED ON WAVELET COEFFICIENTS

    DEFF Research Database (Denmark)

    Pavlov, A.N.; Pavlova, O.N.; Mosekilde, Erik;

    2010-01-01

    The purpose of this study is to demonstrate the possibility of revealing new characteristic features of renal blood flow autoregulation in healthy and pathological states through the application of discrete wavelet transforms to experimental time series for normotensive and hypertensive rats....... A reduction in the variability of the wavelet coefficients in hypertension is observed at both the microscopic level of the blood flow in efferent arterioles of individual nephrons and at the macroscopic level of the blood pressure in the main arteries. The reduction is manifest in both of the main frequency...

  11. Abnormality in cerebellar blood flow in solo vertigo patients

    Energy Technology Data Exchange (ETDEWEB)

    Nagahori, Takeshi [Shakaihoken Takaoka Hospital, Toyama (Japan); Nishijima, Michiharu; Endo, Shunro; Takaku, Akira

    1997-03-01

    Little is known about the blood flow of the vertebrobasilar system as a cause of vertigo and dizziness. We used Xe-CT to study cerebellar blood flow in 53 patients who ranged in age from 35 to 85 years. The patients were divided into two groups. One of them was the vertigo group that comprised 28 patients with rotatory sensation, and the other, the non-vertigo group of 25 patients with a sensation other than rotation. At the stage of severe symptoms, there was decreased cerebellar blood flow in all patients of both, the vertigo and the non-vertigo groups, and a decrease in the bilateral cerebellar hemisphere was observed in five patients and in a unilateral hemisphere in three patients of the vertigo group. By comparison, in the non-vertigo group, unilateral decrease of cerebellar blood flow was observed in only one patient, and a bilateral decrease in five. At the stage of severe symptoms, the mean regional cerebellar blood flow was 40.5{+-}8.0 ml/100 g/min (n=16 sides) in the vertigo group and 45.3{+-}9.5 ml/100 g/min (n=12 sides) in the non-vertigo group. At the stage of moderate symptoms, blood flow image was normal in four of 14 vertigo patients and in seven of 12 non-vertigo patients. The mean regional blood flow was 47.8{+-}8.6 ml/100 g/min (n=28 sides) in the vertigo group and 47.1{+-}5.1 ml/100 g/min (n=24 sides) in the non-vertigo group. At the asymptomatic stage, a high proportion of normal blood flow images (nine of 16 vertigo patients and 10 of 10 non-vertigo patients) was observed. The mean regional cerebellar blood flow was 51.6{+-}10.7 ml/100 g/min (n=32 sides) in the vertigo group and 52.8{+-}8.5 ml/100 g/min (n=20 sides) in the non-vertigo group. This study demonstrates that a unilateral or bilateral decrease in blood flow of the vertebrobasilar system may cause vertigo and dizziness. It also shows that Xe-CT of the cerebellum may be a valuable examination modality for the diagnosis and treatment of vertigo and dizziness. (author)

  12. A multiple disk centrifugal pump as a blood flow device.

    Science.gov (United States)

    Miller, G E; Etter, B D; Dorsi, J M

    1990-02-01

    A multiple disk, shear force, valveless centrifugal pump was studied to determine its suitability as a blood flow device. A pulsatile version of the Tesla viscous flow turbine was designed by modifying the original steady flow pump concept to produce physiological pressures and flows with the aid of controlling circuitry. Pressures and flows from this pump were compared to a Harvard Apparatus pulsatile piston pump. Both pumps were connected to an artificial circulatory system. Frequency and systolic duration were varied over a range of physiological conditions for both pumps. The results indicated that the Tesla pump, operating in a pulsatile mode, is capable of producing physiologic pressures and flows similar to the Harvard pump and other pulsatile blood pumps.

  13. Viscoelastic capillary flow: the case of whole blood

    Directory of Open Access Journals (Sweden)

    David Rabaud

    2016-07-01

    Full Text Available The dynamics of spontaneous capillary flow of Newtonian fluids is well-known and can be predicted by the Lucas-Washburn-Rideal (LWR law. However a wide variety of viscoelastic fluids such as alginate, xanthan and blood, does not exhibit the same Newtonian behavior.In this work we consider the Herschel-Bulkley (HB rheological model and Navier-Stokes equation to derive a generic expression that predicts the capillary flow of non-Newtonian fluids. The Herschel-Bulkley rheological model encompasses a wide variety of fluids, including the Power-law fluids (also called Ostwald fluids, the Bingham fluids and the Newtonian fluids. It will be shown that the proposed equation reduces to the Lucas-Washburn-Rideal law for Newtonian fluids and to the Weissenberg-Rabinowitsch-Mooney (WRM law for power-law fluids. Although HB model cannot reduce to Casson’s law, which is often used to model whole blood rheology, HB model can fit the whole blood rheology with the same accuracy.Our generalized expression for the capillary flow of non-Newtonian fluid was used to accurately fit capillary flow of whole blood. The capillary filling of a cylindrical microchannel by whole blood was monitored. The blood first exhibited a Newtonian behavior, then after 7 cm low shear stress and rouleaux formation made LWR fails to fit the data: the blood could not be considered as Newtonian anymore. This non-Newtonian behavior was successfully fit by the proposed equation.

  14. Coded ultrasound for blood flow estimation using subband processing

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Nielsen, Michael bachmann

    2007-01-01

    This paper further investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband...... was carried out using an experimental ultrasound scanner and a commercial linear array 7 MHz transducer. A circulating flow rig was scanned with a beam-to-flow angle of 60 degrees. The flow in the rig was laminar and had a parabolic flow-profile with a peak velocity of 0.09 m/s. The mean relative standard...

  15. Tubuloglomerular feedback dynamics and renal blood flow autoregulation in rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Wagner, A J; Marsh, D J

    1991-01-01

    To decide whether tubuloglomerular feedback (TGF) can account for renal autoregulation, we tested predictions of a TGF simulation. Broad-band and single-frequency perturbations were applied to arterial pressure; arterial blood pressure, renal blood flow and proximal tubule pressure were measured....... Data were analyzed by linear systems analysis. Broad-band forcings of arterial pressure were also applied to the model to compare experimental results with simulations. With arterial pressure as the input and tubular pressure, renal blood flow, or renal vascular resistance as outputs, the model......Hz in which, in addition, there are autonomous oscillations in TGF. Higher amplitude forcings in this band were attenuated by autoregulatory mechanisms, but low-amplitude forcings entrained the autonomous oscillations and provoked amplified oscillations in blood flow, showing an effect of TGF on whole kidney...

  16. Quantifying Blood Flow in the DIEP Flap: An Ultrasonographic Study

    Directory of Open Access Journals (Sweden)

    Joseph Richard Dusseldorp, BCom, MBBS(Hons

    2014-10-01

    Conclusions: This study confirms that perforator size is a critical factor in optimizing blood flow in perforator-based free tissue transfer. Further research is required to understand the flow dynamics of perforator flaps based on multiple perforators. However, surgeons should be cognizant that a single large perforator may have substantially higher flow rates than multiple small perforators. Routine FVI calculation is recommended to ensure complete flap survival.

  17. Pulsatile blood flow, shear force, energy dissipation and Murray's Law

    Directory of Open Access Journals (Sweden)

    Bengtsson Hans-Uno

    2006-08-01

    Full Text Available Abstract Background Murray's Law states that, when a parent blood vessel branches into daughter vessels, the cube of the radius of the parent vessel is equal to the sum of the cubes of the radii of daughter blood vessels. Murray derived this law by defining a cost function that is the sum of the energy cost of the blood in a vessel and the energy cost of pumping blood through the vessel. The cost is minimized when vessel radii are consistent with Murray's Law. This law has also been derived from the hypothesis that the shear force of moving blood on the inner walls of vessels is constant throughout the vascular system. However, this derivation, like Murray's earlier derivation, is based on the assumption of constant blood flow. Methods To determine the implications of the constant shear force hypothesis and to extend Murray's energy cost minimization to the pulsatile arterial system, a model of pulsatile flow in an elastic tube is analyzed. A new and exact solution for flow velocity, blood flow rate and shear force is derived. Results For medium and small arteries with pulsatile flow, Murray's energy minimization leads to Murray's Law. Furthermore, the hypothesis that the maximum shear force during the cycle of pulsatile flow is constant throughout the arterial system implies that Murray's Law is approximately true. The approximation is good for all but the largest vessels (aorta and its major branches of the arterial system. Conclusion A cellular mechanism that senses shear force at the inner wall of a blood vessel and triggers remodeling that increases the circumference of the wall when a shear force threshold is exceeded would result in the observed scaling of vessel radii described by Murray's Law.

  18. Intrinsic regulation of blood flow in adipose tissue

    DEFF Research Database (Denmark)

    Henriksen, O; Nielsen, Steen Levin; Paaske, W

    1976-01-01

    Previous studies on intact human subcutaneous tissue have shown, that blood flow remains constant during minor changes in perfusion pressure. This so-called autoregulatory response has not been demonstrable in isolated preparations of adipose tissue. In the present study on isolated, denervated...... subcutaneous tissue in female rabbits only 2 of 12 expts. revealed an autoregulatory response during reduction in arterial perfusion pressure. Effluent blood flow from the tissue in the control state was 15.5 ml/100 g-min (S.D. 6.4, n = 12) corresponding to slight vasodilatation of the exposed tissue....... Following total ischemia all experiments showed a period with reactive hyperemia, and both duration of hyperemia and excess flow was related to the duration of the ischemia. This response therefore seems more resistant to the experimental procedure, while autoregulation of blood flow to lowered pressure...

  19. Cerebral blood flow tomography with xenon-133

    DEFF Research Database (Denmark)

    Lassen, N A

    1985-01-01

    and investigative purposes. This article discusses in particular its use for the selection of patients with carotid occlusion for extracranial/intracranial bypass surgery, for detection of severe arterial spasm after aneurysm bleeding, and for detection of low flow areas during severe migraine attacks. The use...

  20. Physiologic Assessment of Coronary Artery Disease: Focus on Fractional Flow Reserve

    OpenAIRE

    Hwang, Doyeon; Lee, Joo Myung; Koo, Bon-Kwon

    2016-01-01

    The presence of myocardial ischemia is the most important prognostic factor in patients with ischemic heart disease. Fractional flow reserve (FFR) is a gold standard invasive method used to detect the stenosis-specific myocardial ischemia. FFR-guided revascularization strategy is superior to angiography-guided strategy. The recently developed hyperemia-free index, instantaneous wave free ratio is being actively investigated. A non-invasive FFR derived from coronary CT angiography is now used ...

  1. Fractional flow reserve-guided PCI for stable coronary artery disease

    DEFF Research Database (Denmark)

    De Bruyne, Bernard; Fearon, William F; Pijls, Nico H J

    2014-01-01

    BACKGROUND: We hypothesized that in patients with stable coronary artery disease and stenosis, percutaneous coronary intervention (PCI) performed on the basis of the fractional flow reserve (FFR) would be superior to medical therapy. METHODS: In 1220 patients with stable coronary artery disease, we......-therapy group (8.1% vs. 19.5%; hazard ratio, 0.39; 95% confidence interval [CI], 0.26 to 0.57; Pratio, 0.23; 95% CI, 0.14 to 0.38; P

  2. Peripheral blood flow control in diabetes mellitus

    DEFF Research Database (Denmark)

    Hilsted, Jannik

    1991-01-01

    Long term diabetes has a profound effect on the peripheral circulation. This has been demonstrated to be due to the presence of angiopathy and autonomic neuropathy, affecting autoregulation and distensibility of the vessels as well as local and central reflex regulation of the vascular resistance....... Whereas the hemodynamic consequences of vascular denervation are well known (causing blood pressure maladaptation to a number of stimuli such as standing, exercise and agonist infusion) (Hilsted 1985), the consequences of disturbances in autoregulation and distensibility remain to be established....

  3. Diagnostic Accuracy of Stress Myocardial Perfusion Imaging Compared to Invasive Coronary Angiography With Fractional Flow Reserve Meta-Analysis

    NARCIS (Netherlands)

    Takx, Richard A. P.; Blomberg, Bjorn A.; El Aidi, Hamza; Habets, Jesse; de Jong, Pim A.; Nagel, Eike; Hoffmann, Udo; Leiner, Tim

    2015-01-01

    Background-Hemodynamically significant coronary artery disease is an important indication for revascularization. Stress myocardial perfusion imaging is a noninvasive alternative to invasive fractional flow reserve for evaluating hemodynamically significant coronary artery disease. The aim was to det

  4. Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis

    DEFF Research Database (Denmark)

    Schytz, Philip Andreas; Mace, Maria Lerche; Soja, Anne Merete Boas

    2015-01-01

    BACKGROUND: If blood pressure (BP) falls during haemodialysis (HD) [intradialytic hypotension (IDH)] a common clinical practice is to reduce the extracorporeal blood flow rate (EBFR). Consequently the efficacy of the HD (Kt/V) is reduced. However, only very limited knowledge on the effect of redu...

  5. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H;

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  6. Design and Simulation of Axial Flow Maglev Blood Pump

    Directory of Open Access Journals (Sweden)

    Huachun Wu

    2011-03-01

    Full Text Available The axial flow maglev blood pump (AFMBP has become a global research focus and emphasis for artificial ventricular assist device, which has no mechanical contact, mechanical friction, compact structure and light weight, can effectively solve thrombus and hemolysis. Magnetic suspension and impeller is two of the important parts in the axial flow maglev blood pump, and their structure largely determines the blood pump performance. The research adopts electromagnetic and fluid finite element analysis, and puts forward a method to design the magnetic suspension and impeller of axial flow blood pump, which tacks into account the small volume of axial blood pump. The magnetic bearing’s characteristics are evaluated by electromagnetic finite element analysis. The Blades have been designed by calculating aerofoil bone line, and make simulation analysis for different thicken ways of blade by Fluent software, and make a conclusion that the blade thickened with certain rules has better characteristics in the same conditions. The results will provide some guidance for design of axial flow maglev blood pump, and establish theoretical basis for application of the implantable artificial heart pump.

  7. Mean arterial pressure change associated with cerebral blood flow in healthy older adults.

    Science.gov (United States)

    Deverdun, Jeremy; Akbaraly, Tasnime N; Charroud, Celine; Abdennour, Meriem; Brickman, Adam M; Chemouny, Stephane; Steffener, Jason; Portet, Florence; Bonafe, Alain; Stern, Yaakov; Ritchie, Karen; Molino, François; Le Bars, Emmanuelle; Menjot de Champfleur, Nicolas

    2016-10-01

    We investigate over a 12-year period the association between regional cerebral blood flow (CBF) and cardiovascular risk factors in a prospective cohort of healthy older adults (81.96 ± 3.82 year-old) from the Cognitive REServe and Clinical ENDOphenotype (CRESCENDO) study. Cardiovascular risk factors were measured over 12 years, and gray matter CBF was measured at the end of the study from high-resolution magnetic resonance imaging using arterial spin labeling. The association between cardiovascular risk factors, their long-term change, and CBF was assessed using multivariate linear regression models. Women were observed to have higher CBF than men (p < 0.05). Increased mean arterial pressure (MAP) over the 12-year period was correlated with a low cerebral blood flow (p < 0.05, R(2) = 0.21), whereas no association was detected between CBF and MAP at the time of imaging. High levels of glycemia tended to be associated with low cerebral blood flow values (p < 0.05). Age, alcohol consumption, smoking status, body mass index, history of cardiovascular disease, and hypertension were not associated with CBF. Our main result suggests that change in MAP is the most significant predictor of future CBF in older adults.

  8. Species diversity, habitat utilization and blood parasites of amphibians in and around Ndumo Game Reserve / Edward Charles Netherlands

    OpenAIRE

    Netherlands, Edward Charles

    2014-01-01

    Ndumo Game Reserve is the only officially protected area within the Phongolo Floodplain; an area in the northern parts of KwaZulu-­‐Natal known to boast a rich diversity of amphibians, thus becoming one of the focal areas for this study. The study’s aim was to monitor and record amphibian diversity, as well as associated blood parasi...

  9. Complex blood flow quantification using real-time in vivo vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Per, Haugaard;

    A new method to define and quantify complex blood flow is presented. The standard deviations of real-time in vivo vector flow angle estimates are used. Using vector flow ultrasound imaging both carotid bifurcations of two healthy volunteers were scanned. Scanning was performed with a 7.6 MHz linear...... patterns can be visualised and quantified with real-time in vivo vector flow. Good agreement between visual evaluation and the quantitative method has been shown. A standard deviation of vector angle estimates above 30 is proposed to define complex blood flow....

  10. [The landmarks of the measurement of cerebral blood flow].

    Science.gov (United States)

    István, Nyáry

    2008-01-30

    History of the measurement of local cerebral blood flow may cover a period of one and a half centuries. Parallel forthcoming of both theoretical and technical development were the key elements of ensuing progress resulting in the present state, when by the aid of in vivo blood flow and metabolic maps, we can visualize locales of brain functioning and their interconnections. Two theoretical landmarks should be mentioned in this historic process. First, the work of Adolf Fick, as the starter of quantitative measurements in this field, and Seymour Kety's model of a single, homogenously perfused tissue element. The solution of this model, in the form of Kety's equation is still fundamental to present day blood flow mapping techniques. Among the numerous investigators over the past years, two Hungarian scientist can be named as major contributors. Kálmán Sántha made substantial studies with continuous registration of local cerebral blood flow by the aid of thermocouples, while Emil P6sztor invented the hydrogen clearance method for the measurement of local cerebral blood flow both in human and in animal studies.

  11. Regional neurohypophysial and hypothalamic blood flow in rats during hypercapnia

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, R.M. Jr.; Myers, C.L.; Page, R.B.

    1988-08-01

    Regional cerebral blood flow (rCBF) was measured in the neurohypophysis and hypothalamus in normocapnic and hypercapnic rats using (/sup 14/C)isopropyliodoamphetamine. Rats were surgically prepared using nitrous oxide and halothane and placed in plaster restraining casts. Hypercapnia was produced by increasing the fractional concentration of inspired CO/sub 2/ (FICO/sub 2/). rCBF in normocapnic rats was higher in the paraventricular nucleus, supraoptic nucleus, median eminence, and neural lobe than rates previously measured by use of diffusible tracers. During hypercapnia blood flow increased linearly with arterial PCO/sub 2/ (PACO/sub 2/) in all regions except the median eminence and neural lobe, which were not affected by hypercapnia. When rats were pretreated with phentolamine (1 mg/kg) to block the alpha-adrenergic receptors, blood flow in the median eminence and neural lobe increased significantly during hypercapnia. We conclude that blood flow in the cell bodies of the paraventricular nucleus and supraoptic nucleus is regulated differently during hypercapnia than blood flow in the nerve terminals in the median eminence and neural lobe. Furthermore, vasodilation produced by increased CO/sub 2/ is offset by alpha-receptor stimulation in the median eminence and neural lobe.

  12. An analysis of the sluicing gate in pulmonary blood flow.

    Science.gov (United States)

    Fung, Y C; Zhuang, F Y

    1986-05-01

    For pulmonary blood flow in zone 2 condition, in which the blood pressure in the venule (pven) is lower than the alveolar gas pressure (pA), the blood exiting from the capillary sheet and entering a venule must go through a sluicing gate. The sluicing gate exists because the venule remains patent while the capillaries will collapse when the static pressure of blood falls below the alveolar gas pressure. In the original theory of sheet flow the effect of the tension in the interalveolar septa on the flow through the sluicing gate was ignored. Since the tension multiplied by the curvature of the membrane is equivalent to a lateral pressure tending to open the gate, and since the curvature of the capillary wall is high in the gate region, this effect may be important. The present analysis improves the original theory and demonstrates that the effect of membrane tension is to cause flow to increase when the venous pressure continues to decrease. The shape of the sluicing gate resembles that of a venturi tube, and can be determined by an iterative integration of the differential equations. The result forms an important link in the theory of pulmonary blood flow in zone 2 condition.

  13. Effects of Aortic Irregularities on the Blood Flow

    Science.gov (United States)

    Gutmark-Little, Iris; Prahl-Wittberg, Lisa; van Wyk, Stevin; Mihaescu, Mihai; Fuchs, Laszlo; Backeljauw, Philippe; Gutmark, Ephraim

    2013-11-01

    Cardiovascular defects characterized by geometrical anomalies of the aorta and its effect on the blood flow are investigated. The flow characteristics change with the aorta geometry and the rheological properties of the blood. Flow characteristics such as wall shear stress often play an important role in the development of vascular disease. In the present study, blood is considered to be non-Newtonian and is modeled using the Quemada model, an empirical model that is valid for different red blood cell loading. Three patient-specific aortic geometries are studied using Large Eddy Simulations (LES). The three geometries represent malformations that are typical in patients populations having a genetic disorder called Turner syndrome. The results show a highly complex flow with regions of recirculation that are enhanced in two of the three aortas. Moreover, blood flow is diverted, due to the malformations, from the descending aorta to the three side branches of the arch. The geometry having an elongated transverse aorta has larger areas of strong oscillatory wall shear stress.

  14. Instantaneous wave-free ratio to guide coronary revascularization: physiological framework, validation and differences with fractional flow reserve.

    Science.gov (United States)

    de Waard, Guus A; Di Mario, Carlo; Lerman, Amir; Serruys, Patrick W; van Royen, Niels

    2017-02-14

    Determining the optimal treatment strategy for revascularization of coronary artery stenosis involves the use of fractional flow reserve (FFR). To improve the low clinical uptake of physiological lesion assessment to guide revascularization, the instantaneous wave-free period (iFR) was proposed as a simpler alternative to FFR that does not require adenosine administration. iFR is calculated as the ratio of blood pressure distal and proximal to a coronary artery stenosis during the diastolic wave- free period. The wave-free period is a part of the cardiac cycle where generation of new pressure wavefronts does not occur and resting microvascular resistance is relatively minimized. iFR indicates the hemodynamic severity of a stenosis, by assessing the extent to which the epicardial stenosis depletes the microcirculatory, autoregulatory reserve. The introduction of iFR and the potential to assess hemodynamic stenosis severity without the need for administration of potent vasodilators such as adenosine, sparked an interesting debate about the fundamentals of human coronary physiology. Outcomes of two randomized clinical trials investigating iFR are pending. These studies are designed to evaluate whether iFR guided revascularisation is non-inferior to an FFR guided approach. The purpose of this review article is to discuss the physiological concepts underlying iFR, examine the existing validation studies and discuss the advantages and disadvantages of iFR as compared to FFR.

  15. Nonuniform blood flow in the canine left ventricle.

    Science.gov (United States)

    Flynn, A E; Coggins, D L; Austin, R E; Muehrcke, D D; Aldea, G S; Goto, M; Doucette, J W; Hoffman, J I

    1990-11-01

    In order to investigate the relationship between coronary perfusion pressure and blood flow distribution in the left ventricle (LV), we measured myocardial blood flow in small regions using radioactive microspheres in six anesthetized, open-chest dogs. Mean coronary perfusion pressure (CPP) was controlled with a femoral artery to left main coronary artery shunt which included a pressurized, servo-controlled blood reservoir. In each dog, we measured flow in 192 regions of the LV free wall (mean weight per region = 206 +/- 38 mg) at different perfusion pressures. At CPP = 80 mm Hg, blood flow to individual regions varied fourfold (0.30 to 1.18 ml/min/g; relative dispersion (RD) = 21.8 +/- 2.3%). At CPP = 50 mm Hg, flow varied over sevenfold (0.08 to 0.60 ml/min/g; RD = 42.8 +/- 10%; P less than 0.01 vs 80 mm Hg). This relationship between flow variability and CPP was present within individual LV layers as well between layers and is much higher than the error associated with the microsphere technique. We conclude that blood flow to small regions of the LV is markedly nonuniform. This heterogeneity becomes more profound at lower CPP. These findings suggest that (1) global measurements of coronary flow must be interpreted with caution, and (2) even in hearts with normal coronary arteries some regions of the LV are more susceptible to ischemia than others. In addition, these findings may help explain the patchy nature of myocardial damage that occurs following periods of low coronary pressure or inadequate myocardial protection during cardiopulmonary bypass.

  16. Coded Ultrasound for Blood Flow Estimation Using Subband Processing

    DEFF Research Database (Denmark)

    Gran, Fredrik; Udesen, Jesper; Nielsen, Michael Bachamnn

    2008-01-01

    This paper investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband coded...... for velocity estimation is compared with a conventional approach transmitting a narrow-band pulse. The study was carried out using an experimental ultrasound scanner and a commercial linear array 7 MHz transducer. A circulating flow rig was scanned with a beam-to-flow angle of 60°. The flow in the rig...

  17. Maximum Likelihood Blood Velocity Estimator Incorporating Properties of Flow Physics

    DEFF Research Database (Denmark)

    Schlaikjer, Malene; Jensen, Jørgen Arendt

    2004-01-01

    The aspect of correlation among the blood velocities in time and space has not received much attention in previous blood velocity estimators. The theory of fluid mechanics predicts this property of the blood flow. Additionally, most estimators based on a cross-correlation analysis are limited...... of simulated and in vivo data from the carotid artery. The estimator is meant for two-dimensional (2-D) color flow imaging. The resulting mathematical relation for the estimator consists of two terms. The first term performs a cross-correlation analysis on the signal segment in the radio frequency (RF......)-data under investigation. The flow physic properties are exploited in the second term, as the range of velocity values investigated in the cross-correlation analysis are compared to the velocity estimates in the temporal and spatial neighborhood of the signal segment under investigation. The new estimator...

  18. Mediators of increased blood flow in porcine skin

    Directory of Open Access Journals (Sweden)

    H. D. Moore

    1992-01-01

    Full Text Available Nicotinates and benzalkonium chloride (B.Cl cause inflammatory changes in human skin, thought to be dependent upon prostaglandin formation. This study has examined the effects of hexyl-nicotinate (HN and B.Cl on blood flow in porcine skin. The role of prostaglandins and interleukin (IL-1 in the blood flow response has been investigated. Blood flow was increased by both HN and B.Cl, the response to B.Cl being more protracted. Cyclooxygenase inhibitor pretreatment reduced these responses. IL-1-like biological activity was identified in normal porcine epidermis and the amounts recovered from inflamed skin were similar. Thus prostaglandin formation in HN or B.Cl-induced inflammation, if IL-1 dependent, is not associated with the loss of significant amounts of the cytokine from the epidermis.

  19. Regulation of the skeletal muscle blood flow in humans

    DEFF Research Database (Denmark)

    Mortensen, Stefan; Saltin, Bengt

    2014-01-01

    In humans, skeletal muscle blood flow is regulated by an interaction between several locally formed vasodilators including nitric oxide (NO) and prostaglandins. In plasma, ATP is a potent vasodilator that stimulates the formation of NO and prostaglandins and very importantly can offset local...... concentration does not increase during exercise. In the skeletal muscle interstitium, there is a marked increase in the concentration of ATP and adenosine and this increase is tightly coupled to the increase in blood flow. The sources of interstitial ATP and adenosine are thought to be skeletal muscle cells...... hyperaemia whereas the role of ATP remains uncertain due to lack of specific purinergic receptor blockers for human use. The purpose of this review is to address the interaction between vasodilator systems and to discuss the multiple proposed roles of ATP in human skeletal muscle blood flow regulation...

  20. Coronary blood flow during cardiopulmonary resuscitation in swine

    Energy Technology Data Exchange (ETDEWEB)

    Bellamy, R.F.; DeGuzman, L.R.; Pedersen, D.C.

    1984-01-01

    Recent papers have raised doubt as to the magnitude of coronary blood flow during closed-chest cardiopulmonary resuscitation. We will describe experiments that concern the methods of coronary flow measurement during cardiopulmonary resuscitation. Nine anesthetized swine were instrumented to allow simultaneous measurements of coronary blood flow by both electromagnetic cuff flow probes and by the radiomicrosphere technique. Cardiac arrest was caused by electrical fibrillation and closed-chest massage was performed by a Thumper (Dixie Medical Inc., Houston). The chest was compressed transversely at a rate of 66 strokes/min. Compression occupied one-half of the massage cycle. Three different Thumper piston strokes were studied: 1.5, 2, and 2.5 inches. Mean aortic pressure and total systemic blood flow measured by the radiomicrosphere technique increased as Thumper piston stroke was lengthened (mean +/- SD): 1.5 inch stroke, 23 +/- 4 mm Hg, 525 +/- 195 ml/min; 2 inch stroke, 33 +/- 5 mm Hg, 692 +/- 202 ml/min; 2.5 inch stroke, 40 +/- 6 mm Hg, 817 +/- 321 ml/min. Both methods of coronary flow measurement (electromagnetic (EMF) and radiomicrosphere (RMS)) gave similar results in technically successful preparations (data expressed as percent prearrest flow mean +/- 1 SD): 1.5 inch stroke, EMF 12 +/- 5%, RMS 16 +/- 5%; 2 inch stroke, EMF 30 +/- 6%, RMS 26 +/- 11%; 2.5 inch stroke, EMF 50 +/- 12%, RMS 40 +/- 20%. The phasic coronary flow signal during closed-chest compression indicated that all perfusion occurred during the relaxation phase of the massage cycle. We concluded that coronary blood flow is demonstrable during closed-chest massage, but that the magnitude is unlikely to be more than a fraction of normal.

  1. Flow of Red Blood Cells in Stenosed Microvessels

    Science.gov (United States)

    Vahidkhah, Koohyar; Balogh, Peter; Bagchi, Prosenjit

    2016-06-01

    A computational study is presented on the flow of deformable red blood cells in stenosed microvessels. It is observed that the Fahraeus-Lindqvist effect is significantly enhanced due to the presence of a stenosis. The apparent viscosity of blood is observed to increase by several folds when compared to non-stenosed vessels. An asymmetric distribution of the red blood cells, caused by geometric focusing in stenosed vessels, is observed to play a major role in the enhancement. The asymmetry in cell distribution also results in an asymmetry in average velocity and wall shear stress along the length of the stenosis. The discrete motion of the cells causes large time-dependent fluctuations in flow properties. The root-mean-square of flow rate fluctuations could be an order of magnitude higher than that in non-stenosed vessels. Several folds increase in Eulerian velocity fluctuation is also observed in the vicinity of the stenosis. Surprisingly, a transient flow reversal is observed upstream a stenosis but not downstream. The asymmetry and fluctuations in flow quantities and the flow reversal would not occur in absence of the cells. It is concluded that the flow physics and its physiological consequences are significantly different in micro- versus macrovascular stenosis.

  2. Intraoperative multi-exposure speckle imaging of cerebral blood flow.

    Science.gov (United States)

    Richards, Lisa M; Kazmi, Sm Shams; Olin, Katherine E; Waldron, James S; Fox, Douglas J; Dunn, Andrew K

    2017-01-01

    Multiple studies have demonstrated that laser speckle contrast imaging (LSCI) has high potential to be a valuable cerebral blood flow monitoring technique during neurosurgery. However, the quantitative accuracy and sensitivity of LSCI is limited, and highly dependent on the exposure time. An extension to LSCI called multi-exposure speckle imaging (MESI) overcomes these limitations, and was evaluated intraoperatively in patients undergoing brain tumor resection. This clinical study ( n = 8) recorded multiple exposure times from the same cortical tissue area spanning 0.5-20 ms, and evaluated images individually as single-exposure LSCI and jointly using the MESI model. This study demonstrated that the MESI estimates provided the broadest flow sensitivity for sampling the flow magnitude in the human brain, closely followed by the shorter exposure times. Conservation of flow analysis on vascular bifurcations was used to validate physiological accuracy, with highly conserved flow estimates (blood flow changes after tissue cautery. Results from this study demonstrate that intraoperative MESI can be performed with high quantitative accuracy and sensitivity for cerebral blood flow monitoring.

  3. Diabetes augments in vivo microvascular blood flow dynamics after stroke.

    Science.gov (United States)

    Tennant, Kelly A; Brown, Craig E

    2013-12-04

    Stroke usually affects people with underlying medical conditions. In particular, diabetics are significantly more likely to have a stroke and the prognosis for recovery is poor. Because diabetes is associated with degenerative changes in the vasculature of many organs, we sought to determine how hyperglycemia affects blood flow dynamics after an ischemic stroke. Longitudinal in vivo two-photon imaging was used to track microvessels before and after photothrombotic stroke in a diabetic mouse model. Chronic hyperglycemia exacerbated acute (3-7 d) ischemia-induced increases in blood flow velocity, vessel lumen diameter, and red blood cell flux in peri-infarct regions. These changes in blood flow dynamics were most evident in superficial blood vessels within 500 μm from the infarct, rather than deeper or more distant cortical regions. Long-term imaging of diabetic mice not subjected to stroke indicated that these acute stroke-related changes in vascular function could not be attributed to complications from hyperglycemia alone. Treating diabetic mice with insulin immediately after stroke resulted in less severe alterations in blood flow within the first 7 d of recovery, but had more variable results at later time points. Analysis of microvessel branching patterns revealed that stroke led to a pruning of microvessels in peri-infarct cortex, with very few instances of sprouting. These results indicate that chronic hyperglycemia significantly affects the vascular response to ischemic stroke and that insulin only partially mitigates these changes. The combination of these acute and chronic alterations in blood flow dynamics could underlie diabetes-related deficits in cortical plasticity and stroke recovery.

  4. Fontan Outcomes and Pulmonary Blood Flow at Birth.

    Science.gov (United States)

    Evans, William N; Acherman, Ruben J; Reardon, Leigh C; Ciccolo, Michael L; Galindo, Alvaro; Rothman, Abraham; Winn, Brody J; Yumiaco, Noel S; Restrepo, Humberto

    2016-01-01

    We previously noted, in a small group of post-Fontan patients, a possible association between hepatic fibrosis scores and the status of pulmonary blood flow at birth. To further explore this observation, we examined data from all Fontan patients seen in our center from July 2010 to March 2015. We identified 200 patients for analysis. Of the 200 patients, 56 underwent transvenous-hepatic biopsy. Of the 200 patients, 13 (6.5%) had protein-losing enteropathy. We divided both the 56 biopsy patients and the entire cohort of 200 patients into 4 groups: (1) unobstructed pulmonary blood flow at birth with functional left ventricles, (2) unobstructed pulmonary blood flow at birth with functional right ventricles, (3) obstructed pulmonary blood flow at birth with functional left ventricles, and (4) obstructed pulmonary blood flow at birth with functional right ventricles. Analysis of the 56 liver-biopsy patient groups showed median hepatic total-fibrosis scores for the 4 groups of 2 (0-6), 2 (0-8), 3 (2-6), and 4 (1-8), respectively, with statistical significance between groups 4 and 1 (p = 0.031). For the entire cohort of 200 patients, we analyzed the incidence of protein-losing enteropathy for each of the four groups and found protein-losing enteropathy percent occurrences of 0, 2.9, 8.8, and 16.1, respectively, with statistical significance between groups 4 and 2 (p = 0.031) and between groups 4 and 1 (p = 0.025). A history of obstructed pulmonary blood flow at birth, coupled with a functional right ventricle, may predict a poorer long-term Fontan outcome.

  5. Adrenergic influence on gastric mucosal blood flow in gastric fistula dogs

    DEFF Research Database (Denmark)

    Hovendal, C P; Bech, K; Gottrup, F;

    1984-01-01

    by an initial increase in mucosal blood flow and in the last two periods a decrease in blood flow. alpha-Blockade (phentolamine) reduced the pentagastrin stimulated gastric acid secretion and gastric mucosal blood flow but the ratio between blood flow and acid secretion was increased, indicating a relatively...

  6. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  7. Spring-network-based model of a red blood cell for simulating mesoscopic blood flow.

    Science.gov (United States)

    Nakamura, Masanori; Bessho, Sadao; Wada, Shigeo

    2013-01-01

    We developed a mechanical model of a red blood cell (RBC) that is capable of expressing its characteristic behaviors in shear flows. The RBC was modeled as a closed shell membrane consisting of spring networks in the framework of the energy minimum concept. The fluid forces acting on RBCs were modeled from Newton's viscosity law and the conservation of momentum. In a steady shear flow, the RBC model exhibited various behaviors, depending on the shear rate; it tumbled, tank-treaded, or both. The transition from tumbling to tank-treading occurred at a shear rate of 20 s( - 1). The simulation of an RBC in steady and unsteady parallel shear flows (Couette flows) showed that the deformation parameters of the RBC were consistent with experimental results. The RBC in Poiseuille flow migrated radially towards the central axis of the flow channel. Axial migration became faster with an increase in the viscosity of the media, qualitatively consistent with experimental results. These results demonstrate that the proposed model satisfies the essential conditions for simulating RBC behavior in blood flow. Finally, a large-scale RBC flow simulation was implemented to show the capability of the proposed model for analyzing the mesoscopic nature of blood flow.

  8. Splanchnic blood flow and hepatic glucose production in exercising humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L;

    2001-01-01

    The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin-converti......The study examined the implication of the renin-angiotensin system (RAS) in regulation of splanchnic blood flow and glucose production in exercising humans. Subjects cycled for 40 min at 50% maximal O(2) consumption (VO(2 max)) followed by 30 min at 70% VO(2 max) either with [angiotensin...

  9. High speed optical holography of retinal blood flow

    CERN Document Server

    Pellizzari, Mathilde; Degardin, Julie; Sahel, Jose-Alain; Fink, Mathias; Paques, Michel; Atlan, Michael

    2016-01-01

    We performed non-invasive video imaging of retinal blood flow in a pigmented rat by holographic interferometry of near-infrared laser light backscattered by retinal tissue, beating against an off-axis reference beam sampled at a frame rate of 39 kHz with a high throughput camera. Local Doppler contrasts emerged from the envelopes of short-time Fourier transforms and the phase of autocorrelation functions of holograms rendered by Fresnel transformation. This approach permitted imaging of blood flow in large retinal vessels (30 microns diameter) over 400 by 400 pixels with a spatial resolution of 8 microns and a temporal resolution of 6.5 ms.

  10. Age and gender related differences in aortic blood flow

    DEFF Research Database (Denmark)

    Traberg, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian

    2012-01-01

    The abdominal aorta (AA) is predisposed to development of abdominal aneurysms (AAA), a focal dilatation of the artery with fatal consequences if left untreated. The blood flow patterns in the AA is thought to play an important role in the development of AAA. The purpose of this work is to investi......The abdominal aorta (AA) is predisposed to development of abdominal aneurysms (AAA), a focal dilatation of the artery with fatal consequences if left untreated. The blood flow patterns in the AA is thought to play an important role in the development of AAA. The purpose of this work...

  11. Metabolic control of muscle blood flow during exercise in humans

    DEFF Research Database (Denmark)

    Boushel, Robert Christopher

    2003-01-01

    and the vasculature that induce vasodilation. A link between muscle metabolic events and microvascular control of blood flow is illustrated by local dilation of terminal arterioles during contraction of muscle fibers and conduction of vasodilation upstream. Endothelial-derived vasodilator mechanisms are known...... to exert control of muscle vasodilation. Adenosine, nitric oxide (NO), prostacyclin (PGI2), and endothelial-derived hyperpolarization factor (EDHF) are possible mediators of muscle vasodilation during exercise. In humans, adenosine has been shown to contribute to functional hyperemia as blood flow...

  12. Cerebral blood flow and oxidative metabolism during human endotoxemia

    DEFF Research Database (Denmark)

    Møller, Kirsten; Strauss, Gitte Irene; Qvist, Jesper;

    2002-01-01

    The proinflammatory cytokine, tumor necrosis factor-alpha (TNF-alpha), has been suggested to mediate septic encephalopathy through an effect on cerebral blood flow (CBF) and metabolism. The effect of an intravenous bolus of endotoxin on global CBF, metabolism, and net flux of cytokines...... and catecholamines was investigated in eight healthy young volunteers. Cerebral blood flow was measured by the Kety-Schmidt technique at baseline (during normocapnia and voluntary hyperventilation for calculation of subject-specific cerebrovascular CO reactivity), and 90 minutes after an intravenous bolus...

  13. A New Technology for Detecting Cerebral Blood Flow

    DEFF Research Database (Denmark)

    Schytz, Henrik W; Guo, Song; Jensen, Lars T;

    2012-01-01

    There is a need for real-time non-invasive, continuous monitoring of cerebral blood flow (CBF) during surgery, in intensive care units and clinical research. We investigated a new non-invasive hybrid technology employing ultrasound tagged near infrared spectroscopy (UT-NIRS) that may estimate...... changes in CBF using a cerebral blood flow index (CFI). Changes over time for UT-NIRS CFI and (133)Xenon single photon emission computer tomography ((133)Xe-SPECT) CBF data were assessed in 10 healthy volunteers after an intravenous bolus of acetazolamide. UT-NIRS CFI was measured continuously and SPECT...

  14. Accurate blood flow measurements: are artificial tracers necessary?

    Directory of Open Access Journals (Sweden)

    Christian Poelma

    Full Text Available Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case, as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements. These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented.

  15. Accurate blood flow measurements: are artificial tracers necessary?

    Science.gov (United States)

    Poelma, Christian; Kloosterman, Astrid; Hierck, Beerend P; Westerweel, Jerry

    2012-01-01

    Imaging-based blood flow measurement techniques, such as particle image velocimetry, have become an important tool in cardiovascular research. They provide quantitative information about blood flow, which benefits applications ranging from developmental biology to tumor perfusion studies. Studies using these methods can be classified based on whether they use artificial tracers or red blood cells to visualize the fluid motion. We here present the first direct comparison in vivo of both methods. For high magnification cases, the experiments using red blood cells strongly underestimate the flow (up to 50% in the present case), as compared to the tracer results. For medium magnification cases, the results from both methods are indistinguishable as they give the same underestimation of the real velocities (approximately 33%, based on in vitro reference measurements). These results suggest that flow characteristics reported in literature cannot be compared without a careful evaluation of the imaging characteristics. A method to predict the expected flow averaging behavior for a particular facility is presented.

  16. Regional cerebral blood flow in focal cortical epilepsy

    DEFF Research Database (Denmark)

    Hougaard, Kristina Dupont; Oikawa, T; Sveinsdottir, E;

    1976-01-01

    Regional cerebral blood flow (rCBF) was studied in ten patients with focal cortical epilepsy. The blood flow was measured by the intra-arterial injection of xenon 133 (133Xe), and the isotope clearance was recorded by a multidetector scintillation camera with 254 detectors. Three patients were...... studied both during a seizure and (in the same setting) in the interictal period; six patients were studied only in the interictal period, and one patient was studied only during a seizure. Studies during seizures all showed marked flow increases in areas presumed to participate in the seizure activity....... This finding accords with earlier studies. All nine patients studied in the interictal phase showed, either spontaneously or during activation by intermittent light, focal flow increases in areas presumed to comprise the epileptic focus. These interictal hyperemic foci probably reflect subictal neuronal...

  17. Improved technique for blood flow velocity measurement using Doppler effect

    Science.gov (United States)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  18. Optimization of flow reserve measurement using SPECT technology to evaluate the determinants of coronary microvascular dysfunction in diabetes

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Cecilia [CNR Institute of Bioimages and Molecular Physiology, Milan, Section of Genoa (Italy); Bezante, GianPaolo; Modonesi, Elisa; Rollando, Daniela; Balbi, Manrico; Brunelli, Claudio [University of Genoa, Department of Internal Medicine, Cardiology, Genoa (Italy); Gandolfo, Patrizia; Morbelli, Silvia D.; Armonino, Riccardo [University of Genoa, Department of Internal Medicine, Nuclear Medicine, Genoa (Italy); DePascale, Angelo; Maggi, Davide; Albertelli, Manuela; Cordera, Renzo [University of Genoa, Department of Endocrinological Metabolic Sciences, Diabetology, Genoa (Italy); Sambuceti, Gianmario [University of Genoa, Department of Internal Medicine, Nuclear Medicine, Genoa (Italy); Advanced Biotechnology Center, Genoa (Italy)

    2010-02-15

    The aim of this study was to validate a new method to measure regional myocardial perfusion reserve (MPR) with technetium-labelled tracers in patients with type 2 diabetes mellitus (DM2). A total of 40 consecutive DM2 patients without history of coronary artery disease (CAD) and 7 control subjects were recruited. Dipyridamole myocardial blood flow index (MBF) was assessed by measuring first transit counts in the pulmonary artery and myocardial count rate from gated SPECT images using {sup 99m}Tc-labelled tracers. The corresponding MBF index was estimated 2 h later according to the same procedure. Regional myocardial perfusion reserve (MPR) was defined as the ratio between dipyridamole and baseline MBF using a 17-segment left ventricular (LV) model. Coronary flow reserve (CFR) was estimated by transthoracic contrast echo Doppler monitoring of flow velocity in the left anterior descending coronary artery (LAD) during the same session. Estimated MPR was higher in control subjects than in patients (3.36 {+-} 0.66 vs 1.91 {+-} 0.61, respectively, p < 0.01). In patients, LAD CFR and LAD MPR were 2.01 {+-} 0.78 vs 1.93 {+-} 0.63, respectively (p = ns). The agreement between the two techniques was documented by their close correlation (r = 0.92, p < 0.001) and confirmed by the Bland-Altman analysis. Reversible perfusion defects occurred in 13 patients (32%) who showed similar MPR values as the remaining 27 (2.10 {+-} 0.71 vs 1.83 {+-} 0.71, respectively, p = ns). Finally, MPR was closely correlated with age (r = -0.50, p < 0.01) and time elapsed from the diagnosis of DM2 (r = -0.51, p < 0.01). LV regional MPR can be accurately estimated with the broadly available single photon technology. Application of this method to DM2 patients documents the presence of a microvascular dysfunction homogeneously distributed throughout the LV walls and most frequently not associated with reversible perfusion defects. (orig.)

  19. Age and gender related differences in aortic blood flow

    Science.gov (United States)

    Enevoldsen, Marie Sand; Pedersen, Mads Møller; Hemmsen, Martin Christian; Lönn, Lars; Henneberg, Kaj-Åge; Jensen, Jørgen Arendt

    2012-03-01

    The abdominal aorta (AA) is predisposed to development of abdominal aneurysms (AAA), a focal dilatation with fatal consequences if left untreated. The blood flow patterns is thought to play an important role in the development of AAA. The purpose of this work is to investigate the blood flow patterns within a group of healthy volunteers (six females, eight males) aged 23 to 76 years to identify changes and differences related to age and gender. The healthy volunteers were categorized by gender (male/female) and age (below/above 35 years). Subject-specific flow and geometry data were acquired using the research interface on a Profocus ultrasound scanner (B-K Medical, Herlev, Denmark; segmentation of 3D magnetic resonance angiography (Magnetom Trio, Siemens Healthcare, Erlangen, Germany). The largest average diameter was among the elderly males (19.7 (+/- 1.33) mm) and smallest among the young females (12.4 (+/- 0.605) mm). The highest peak systolic velocity was in the young female group (1.02 (+/- 0.336) m/s) and lowest in the elderly male group (0.836 (+/- 0.127) m/s). A geometrical change with age was observed as the AA becomes more bended with age. This also affects the blood flow velocity patterns, which are markedly different from young to elderly. Thus, changes in blood flow patterns in the AA related to age and gender are observed. Further investigations are needed to determine the relation between changes in blood flow patterns and AAA development.

  20. Simulation of the regional groundwater-flow system of the Menominee Indian Reservation, Wisconsin

    Science.gov (United States)

    Juckem, Paul F.; Dunning, Charles P.

    2015-01-01

    A regional, two-dimensional, steady-state groundwater-flow model was developed to simulate the groundwater-flow system and groundwater/surface-water interactions within the Menominee Indian Reservation. The model was developed by the U.S. Geological Survey (USGS), in cooperation with the Menominee Indian Tribe of Wisconsin, to contribute to the fundamental understanding of the region’s hydrogeology. The objectives of the regional model were to improve understanding of the groundwater-flow system, including groundwater/surface-water interactions, and to develop a tool suitable for evaluating the effects of potential regional water-management programs. The computer code GFLOW was used because of the ease with which the model can simulate groundwater/surface-water interactions, provide a framework for simulating regional groundwater-flow systems, and be refined in a stepwise fashion to incorporate new data and simulate groundwater-flow patterns at multiple scales. Simulations made with the regional model reproduce groundwater levels and stream base flows representative of recent conditions (1970–2013) and illustrate groundwater-flow patterns with maps of (1) the simulated water table and groundwater-flow directions, (2) probabilistic areas contributing recharge to high-capacity pumped wells, and (3) estimation of the extent of infiltrated wastewater from treatment lagoons.

  1. Assessment of left anterior descending artery stenosis of intermediate severity by fractional flow reserve, instantaneous wave-free ratio, and non-invasive coronary flow reserve.

    Science.gov (United States)

    Meimoun, P; Clerc, J; Ardourel, D; Djou, U; Martis, S; Botoro, T; Elmkies, F; Zemir, H; Luycx-Bore, A; Boulanger, J

    2016-10-17

    To test the usefulness of non-invasive coronary flow reserve (CFR) by transthoracic Doppler echocardiography by comparison to invasive fractional flow reserve (FFR) and instantaneous wave-free ratio (IFR), a new vasodilator-free index of coronary stenosis severity, in patients with left anterior descending artery (LAD) stenosis of intermediate severity (IS) and stable coronary artery disease. 94 consecutive patients (mean age 68 ± 10 years) with angiographic LAD stenosis of IS (50-70 % diameter stenosis), were prospectively studied. IFR was calculated as a trans-lesion pressure ratio during the wave-free period in diastole; FFR as distal pressure divided by mean aortic pressure during maximal hyperemia (using 180 μg intracoronary adenosine); and CFR as hyperemic peak LAD flow velocity divided by baseline flow velocity using intravenous adenosine (140 μg/kg/min over 2 min). The mean values of IFR, FFR, and CFR were 0.88 ± 0.07, 0.81 ± 0.09, and 2.4 ± 0.6 respectively. A significant correlation was found between CFR and FFR (r = 0. 68), FFR and IFR (r = 0.6), and between CFR and IFR (r = 0.5) (all, p < 0.01). Using a ROC curve analysis, the best cut-off to detect a significant lesion based on FFR assessment (FFR ≤ 0.8, n = 31) was IFR ≤ 0.88 with a sensitivity (Se) of 74 %, specificity (Sp) of 73 %, AUC 0.81 ± 0.04, accuracy 72 %; and CFR ≤ 2 with a Se = 77 %, Sp = 89 %, AUC 0.88 ± 0.04, accuracy 85 % (all, p < 0.001). In stable patients with LAD stenosis of IS, non-invasive CFR is a useful tool to detect a significant lesion based on FFR. Furthermore, there was a better correlation between CFR and FFR than between CFR and IFR, and a trend to a better diagnostic performance for CFR versus IFR.

  2. [Measurement of cerebral blood flow by thermal diffusion using a flow probe with a Peltier stack].

    Science.gov (United States)

    Yamagata, S; Kikuchi, H; Hashimoto, K; Minamikawa, J; Watanabe, Y

    1987-05-01

    In order to evaluate the blood flow by means of thermal diffusion, relationship between blood flow and parameters induced by thermal diffusion was investigated. Flow probe employed for measurement by thermal diffusion incorporated a Peltier stack which contained a small semiconductor and two L-shaped gold plates. These two plates were attached to both sides of the semiconductor by one side of each gold plate and the other side was surfaced with a tissue to be measured. Temperature gradient is created with current applied to the Peltier stack between two plates, one cooled and the other heated, and it is affected only by tissue blood flow. Two kinds of parameters of thermal diffusion were subjected to compare to blood flow. One was temperature gradient when the constant current was applied to the Peltier stack. The other was a current required to maintain a definite temperature gradient which was determined before hand. From the theoretical principle in thermodynamics, the correlations between blood flow and each of thermal diffusion parameters were defined by the following equations: (Formula: see text) where F is blood flow, delta V is voltage converted from temperature gradient, and Ci and Cv are constants. Each of phi v and phi i indicates the characteristics of each probe. Experimental study was carried out to confirm the above relationship using cortex of experimental animals. Under the general anesthesia, a cat was placed in prone position. After the craniotomy, dura mater was opened and a small flow probe, 10 mm in diameter, 5 mm in height and 5 g in weight, was placed on the cortex and blood flow was continuously evaluated by two parameters.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Ultrasonic Doppler blood flow meter for extracorporeal circulation

    Science.gov (United States)

    Dantas, Ricardo G.; Costa, Eduardo T.; Maia, Joaquim M.; Nantes Button, Vera L. d. S.

    2000-04-01

    In cardiac surgeries it is frequently necessary to carry out interventions in internal heart structures, and where the blood circulation and oxygenation are made by artificial ways, out of the patient's body, in a procedure known as extracorporeal circulation (EC). During this procedure, one of the most important parameters, and that demands constant monitoring, is the blood flow. In this work, an ultrasonic pulsed Doppler blood flowmeter, to be used in an extracorporeal circulation system, was developed. It was used a 2 MHz ultrasonic transducer, measuring flows from 0 to 5 liters/min, coupled externally to the EC arterial line destined to adults perfusion (diameter of 9.53 mm). The experimental results using the developed flowmeter indicated a maximum deviation of 3.5% of full scale, while the blood flow estimator based in the rotation speed of the peristaltic pump presented deviations greater than 20% of full scale. This ultrasonic flowmeter supplies the results in a continuous and trustworthy way, and it does not present the limitations found in those flowmeters based in other transduction methods. Moreover, due to the fact of not being in contact with the blood, it is not disposable and it does not need sterilization, reducing operational costs and facilitating its use.

  4. Development of a miniature intraventricular axial flow blood pump.

    Science.gov (United States)

    Yamazaki, K; Umezu, M; Koyanagi, H; Outa, E; Ogino, S; Otake, Y; Shiozaki, H; Fujimoto, T; Tagusari, O; Kitamura, M

    1993-01-01

    A new intraventricular axial flow blood pump has been designed and developed as a totally implantable left ventricular assist device (LVAD). This pump consists of an impeller combined with a guide-vane, a tube housing, and a DC motor. The pump is introduced into the LV cavity through the LV apex, and the outlet cannula is passed antegrade across the aortic valve. Blood is withdrawn from the LV through the inlet ports at the pump base, and discharged to the ascending aorta. Our newly developed axial flow pump system has the following advantages: 1) it is a simple and compact system, 2) minimal blood stasis both in the device and the LV cavity, 3) minimal blood contacting surface of the pump, 4) easy accessibility with a less invasive surgical procedure, and 5) low cost. A pump flow > 5 L/min was obtained against 100 mmHg differential pressure in the mock circulatory system. The pump could produce a passive pulsatile flow effect with a beating heart more efficiently than other non-pulsatile pumps because of minimal pressure drop and inertia along the bypass tract. Anatomic fit studies using dissected hearts of dilated cardiomyopathy (DCM) cadavers showed that this pump could smoothly pass through the aortic valve without any interference with mitral valve function. Recently, a dynamic pressure groove bearing and a miniature lip seal have been developed. The dynamic pressure groove bearing has a simple structure and acts as a pressure resistant sealing mechanism.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Renal blood flow in experimental septic acute renal failure

    NARCIS (Netherlands)

    Langenberg, C.; Wan, L.; Egi, M.; May, C. N.; Bellomo, R.

    2006-01-01

    Reduced renal blood flow (RBF) is considered central to the pathogenesis of septic acute renal failure (ARF). However, no controlled experimental studies have continuously assessed RBF during the development of severe septic ARF. We conducted a sequential animal study in seven female Merino sheep. F

  6. Increased cerebral blood flow in preeclampsia with magnetic resonance imaging

    NARCIS (Netherlands)

    Zeeman, GG; Hatab, MR; Twickler, DM

    2004-01-01

    Objective: The purpose of this study was to compare third trimester and nonpregnant cerebral blood flow of women with preeclampsia to normotensive control subjects with the use of magnetic resonance imaging techniques. Study design: Nine normotensive pregnant women and 12 untreated women with preecl

  7. Longitudinal Cerebral Blood Flow Changes during Speech in Hereditary Ataxia

    Science.gov (United States)

    Sidtis, John J.; Strother, Stephen C.; Naoum, Ansam; Rottenberg, David A.; Gomez, Christopher

    2010-01-01

    The hereditary ataxias constitute a group of degenerative diseases that progress over years or decades. With principal pathology involving the cerebellum, dysarthria is an early feature of many of the ataxias. Positron emission tomography was used to study regional cerebral blood flow changes during speech production over a 21 month period in a…

  8. Nocturnal foot blood flow in patients with arterial insufficiency

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Tønnesen, K H

    1984-01-01

    was on average the same in patients with normal circulations and in patients with different degrees of arterial insufficiency (mean: 2.0 +/- 0.8 ml min-1 100 g-1). During sleep the blood flow nearly doubled in patients with normal circulations; no systematic change was seen in patients with intermittent...

  9. [Measurement of cerebral blood flow using phase-contrast MRI].

    Science.gov (United States)

    Obata, T; Shishido, F; Koga, M; Ikehira, H; Kimura, F; Yoshida, K

    1997-07-01

    The development of phase-contrast magnetic resonance imaging(P-C MRI) provides a noninvasive method for measurement of volumetric blood flow(VFR). The VFR of the left and right internal carotid arteries and basilar artery were measured using P-C MRI, and total cerebral blood flow(tCBF) was calculated by summing up the VFR values in three vessels. We investigated the changes in these blood flows as influenced from age, head size, height, weight, body surface area and handedness. Moreover, regional CBF(rCBF) was measured by combining with the single photon emission computed tomography(SPECT) of 123I. The blood flows were 142 +/- 58 mL/ min(mean +/- SD) in the basilar artery, 229 +/- 86 mL/min in the left, 223 +/- 58 mL/min in the right internal carotid artery, and tCBF was 617 +/- 128 mL/min(Ref. Magn Resn Imaging 14:P. 1143, 1996). Significant increases were observed in head-size-related change of VFR in the basilar artery and height-related change of tCBF. The value of rCBF was easily acquired in combination with SPECT. Phase-contrast MRI is useful for a noninvasive and rapid analysis of cerebral VFR and has potential for clinical use.

  10. Cerebral blood flow response to propranolol in streptozotocin diabetic rats

    DEFF Research Database (Denmark)

    Lass, Preben; Knudsen, G M

    1990-01-01

    The influence of propranolol on cerebral blood flow (CBF) was tested in streptozotocin diabetic rats and in control animals. Resting CBF values were 40% lower in the diabetic rats compared with controls. Intravenous injection of propranolol (2 mg kg-1) decreased CBF significantly in the control...

  11. Influence of blood flow on the coagulation cascade

    DEFF Research Database (Denmark)

    The influence of diffusion and convetive flows on the blood coagulation cascade is investigated for a controlled perfusion experiment. We present a cartoon model and reaction schemes for parts of the coagulation cascade with sunsequent set up of a mathematical model in two space dimensions plus one...

  12. Patterns of regional cerebral blood flow in acute stroke

    DEFF Research Database (Denmark)

    Olsen, T S; Skriver, E B

    1981-01-01

    In a consecutive group of 56 stroke patients the regional cerebral blood flow was measured within 84 hours after stroke. A 254 multidetector scintillation camera and the intracarotid Xenon-133 injection method was used to study rCBF. Typical rCBF-patterns are described and compared to the findings...

  13. Vasodilator interactions in skeletal muscle blood flow regulation

    DEFF Research Database (Denmark)

    Hellsten, Ylva; Nyberg, Michael Permin; Jensen, Lasse Gliemann;

    2012-01-01

    that this remaining hyperemia may be explained by cAMP and cGMP independent smooth muscle relaxation, such as effects of endothelial derived hyperpolarization factors (EDHFs) or through metabolic modulation of sympathetic effects. The nature and role of EDHF as well as potential novel mechanisms in muscle blood flow...

  14. A VARIATIONAL MODEL FOR 2-D MICROPOLAR BLOOD FLOW

    Institute of Scientific and Technical Information of China (English)

    He Ji-huan

    2003-01-01

    The micropolar fluid model is an essential generalization of the well-established Navier-Stokes model in the sense that it takes into account the microstructure of the fluid.This paper is devolted to establishing a variational principle for 2-D incompressible micropolar blood flow.

  15. Optically measured microvascular blood flow contrast of malignant breast tumors.

    Directory of Open Access Journals (Sweden)

    Regine Choe

    Full Text Available Microvascular blood flow contrast is an important hemodynamic and metabolic parameter with potential to enhance in vivo breast cancer detection and therapy monitoring. Here we report on non-invasive line-scan measurements of malignant breast tumors with a hand-held optical probe in the remission geometry. The probe employs diffuse correlation spectroscopy (DCS, a near-infrared optical method that quantifies deep tissue microvascular blood flow. Tumor-to-normal perfusion ratios are derived from thirty-two human subjects. Mean (95% confidence interval tumor-to-normal ratio using surrounding normal tissue was 2.25 (1.92-2.63; tumor-to-normal ratio using normal tissues at the corresponding tumor location in the contralateral breast was 2.27 (1.94-2.66, and using normal tissue in the contralateral breast was 2.27 (1.90-2.70. Thus, the mean tumor-to-normal ratios were significantly different from unity irrespective of the normal tissue chosen, implying that tumors have significantly higher blood flow than normal tissues. Therefore, the study demonstrates existence of breast cancer contrast in blood flow measured by DCS. The new, optically accessible cancer contrast holds potential for cancer detection and therapy monitoring applications, and it is likely to be especially useful when combined with diffuse optical spectroscopy/tomography.

  16. Coded ultrasound for blood flow estimation using subband processing

    DEFF Research Database (Denmark)

    Gran, F.; Udesen, J.; Jensen, J.A.;

    2008-01-01

    This paper investigates the use of coded excitation for blood flow estimation in medical ultrasound. Traditional autocorrelation estimators use narrow-band excitation signals to provide sufficient signal-to-noise-ratio (SNR) and velocity estimation performance. In this paper, broadband coded sign...

  17. Normal Myocardial Flow Reserve in HIV-Infected Patients on Stable Antiretroviral Therapy

    DEFF Research Database (Denmark)

    Knudsen, Andreas; Christensen, Thomas E; Ghotbi, Adam Ali

    2015-01-01

    Studies have found HIV-infected patients to be at increased risk of myocardial infarction, which may be caused by coronary microvascular dysfunction. For the first time among HIV-infected patients, we assessed the myocardial flow reserve (MFR) by Rubidium-82 (82Rb) positron emission tomography (PET......), which can quantify the coronary microvascular function. MFR has proved highly predictive of future coronary artery disease and cardiovascular events in the general population.In a prospective cross-sectional study, HIV-infected patients all receiving antiretroviral therapy (ART) with full viral...... suppression and HIV-uninfected controls were scanned using 82Rb PET/computed tomography at rest and adenosine-induced stress, thereby obtaining the MFR (stress flow/rest flow), stratified into low ≤1.5, borderline >1.5 to 2.0, or normal >2.0.Fifty-six HIV-infected patients and 25 controls were included...

  18. Noninvasive pulsatile flow estimation for an implantable rotary blood pump.

    Science.gov (United States)

    Karantonis, Dean M; Cloherty, Shaun L; Mason, David G; Ayre, Peter J; Lovell, Nigel H

    2007-01-01

    A noninvasive approach to the task of pulsatile flow estimation in an implantable rotary blood pump (iRBP) has been proposed. Employing six fluid solutions representing a range of viscosities equivalent to 20-50% blood hematocrit (HCT), pulsatile flow data was acquired from an in vitro mock circulatory loop. The entire operating range of the pump was examined, including flows from -2 to 12 L/min. Taking the pump feedback signals of speed and power, together with the HCT level, as input parameters, several flow estimate models were developed via system identification methods. Three autoregressive with exogenous input (ARX) model structures were evaluated: structures I and II used the input parameters directly; structure II incorporated additional terms for HCT; and the third structure employed as input a non-pulsatile flow estimate equation. Optimal model orders were determined, and the associated models yielded minimum mean flow errors of 5.49% and 0.258 L/min for structure II, and 5.77% and 0.270 L/min for structure III, when validated on unseen data. The models developed in this study present a practical method of accurately estimating iRBP flow in a pulsatile environment.

  19. Quantitating error in blood flow measurements with radioactive microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Austin, R.E. Jr.; Hauck, W.W.; Aldea, G.S.; Flynn, A.E.; Coggins, D.L.; Hoffman, J.I.

    1989-07-01

    Accurate determination of the reproducibility of measurements using the microsphere technique is important in assessing differences in blood flow to different organs or regions within organs, as well as changes in perfusion under various experimental conditions. The sources of error of the technique are briefly reviewed. In addition, we derived a method for combining quantifiable sources of error into a single estimate that was evaluated experimentally by simultaneously injecting eight or nine sets of microspheres (each with a different radionuclide label) into four anesthetized dogs. Each nuclide was used to calculate blood flow in 145-190 myocardial regions. We compared each flow determination (using a single nuclide label) with a weighted mean for the piece (based on the remaining nuclides). The difference was defined as ''measured'' error. In all, there were a total of 5,975 flow observations. We compared measured error with theoretical estimates based on the Poisson error of radioactive disintegration and microsphere entrapment, nuclide separation error, and reference flow error. We found that combined estimates based on these sources completely accounted for measured error in the relative distribution of microspheres. In addition, our estimates of the error in measuring absolute flows (which were established using microsphere reference samples) slightly, but significantly, underestimated measured error in absolute flow.

  20. Microheterogeneity of blood flow in the rat urinary bladder

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Takahiro [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    2002-08-01

    The microheterogeneity of blood flow in the mucous membrane of the urinary bladder and that in the detrusor muscle in anesthetized rats (n=8) were investigated at an extremely high spatial resolution (0.1 x 0.1 mm{sup 2}) using digital radiography combined with the {sup 3}H-labeled desmethylimipramine deposition technique. The spatial pattern of flow distribution was quantified by the coefficient of variation regional flow (CV: standard deviation/mean). The results showed muscle blood flow to be lower than mucous blood flow (muscle: mucosa=2.9:5), with the distribution of the former being more heterogeneous than that of the latter (CV in muscle vs. CV in mucosa=0.33{+-}0.033 vs. 0.16{+-}0.019, p<0.001) at the capillary level. It was therefore considered that the muscle would more easily experience mechanical irritation and be more easily influenced by arterial tonus than the mucous membrane, ant it was thought that this difference reflected a difference in regional perfusion. (author)

  1. Simulation of red blood cell aggregation in shear flow.

    Science.gov (United States)

    Lim, B; Bascom, P A; Cobbold, R S

    1997-01-01

    A simulation model has been developed for red blood cell (RBC) aggregation in shear flow. It is based on a description of the collision rates of RBC, the probability of particles sticking together, and the breakage of aggregates by shear forces. The influence of shear rate, hematocrit, aggregate fractal dimension, and binding strength on aggregation kinetics were investigated and compared to other theoretical and experimental results. The model was used to simulate blood flow in a long large diameter tube under steady flow conditions at low Reynolds numbers. The time and spatial distribution of the state of aggregation are shown to be in qualitative agreement with previous B-mode ultrasound studies in which a central region of low echogenicity was noted. It is suggested that the model can provide a basis for interpreting prior measurements of ultrasound echogenicity and may help relate them to the local state of aggregation.

  2. Quantitative blood flow velocity imaging using laser speckle flowmetry

    Science.gov (United States)

    Nadort, Annemarie; Kalkman, Koen; van Leeuwen, Ton G.; Faber, Dirk J.

    2016-04-01

    Laser speckle flowmetry suffers from a debated quantification of the inverse relation between decorrelation time (τc) and blood flow velocity (V), i.e. 1/τc = αV. Using a modified microcirculation imager (integrated sidestream dark field - laser speckle contrast imaging [SDF-LSCI]), we experimentally investigate on the influence of the optical properties of scatterers on α in vitro and in vivo. We found a good agreement to theoretical predictions within certain limits for scatterer size and multiple scattering. We present a practical model-based scaling factor to correct for multiple scattering in microcirculatory vessels. Our results show that SDF-LSCI offers a quantitative measure of flow velocity in addition to vessel morphology, enabling the quantification of the clinically relevant blood flow, velocity and tissue perfusion.

  3. Blood flow in the cerebral venous system: modeling and simulation.

    Science.gov (United States)

    Miraucourt, Olivia; Salmon, Stéphanie; Szopos, Marcela; Thiriet, Marc

    2017-04-01

    The development of a software platform incorporating all aspects, from medical imaging data, through three-dimensional reconstruction and suitable meshing, up to simulation of blood flow in patient-specific geometries, is a crucial challenge in biomedical engineering. In the present study, a fully three-dimensional blood flow simulation is carried out through a complete rigid macrovascular circuit, namely the intracranial venous network, instead of a reduced order simulation and partial vascular network. The biomechanical modeling step is carefully analyzed and leads to the description of the flow governed by the dimensionless Navier-Stokes equations for an incompressible viscous fluid. The equations are then numerically solved with a free finite element software using five meshes of a realistic geometry obtained from medical images to prove the feasibility of the pipeline. Some features of the intracranial venous circuit in the supine position such as asymmetric behavior in merging regions are discussed.

  4. Noninvasive miniaturized mass-flow meter using a curved cannula for implantable axial flow blood pump.

    Science.gov (United States)

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yamane, Takashi

    2011-01-01

    Blood flow should be measured to monitor conditions of patients with implantable artificial hearts continuously and noninvasively. We have developed a noninvasive miniaturized mass-flow meter using a curved cannula for an axial flow blood pump. The mass-flow meter utilized centrifugal force generated by the mass-flow rate in the curved cannula. Two strain gauges served as sensors. Based on the numerical analysis, the first gauge, attached to the curved area, measured static pressure and centrifugal force, and the second, attached to the straight area, measured static pressure for static pressure compensation. The mass-flow rate was determined by the differences in output from the two gauges. To compensate for the inertia force under the pulsatile flow, a 0.75-Hz low-pass filter was added to the electrical circuit. In the evaluation tests, numerical analysis and an actual measurement test using bovine blood were performed to evaluate the measurement performances. As a result, in the numerical analysis, the relationship between the differential pressure caused by centrifugal force and the flow rate was verified. In the actual measurement test, measurement error was less than ± 0.5 L/min, and the time delay was 0.12 s. We confirmed that the developed mass-flow meter was able to measure mass-flow rate continuously and noninvasively.

  5. Blood flow simulation on a role for red blood cells in platelet adhesion

    Science.gov (United States)

    Shimizu, Kazuya; Sugiyama, Kazuyasu; Takagi, Shu

    2016-11-01

    Large-scale blood flow simulations were conducted and a role for red blood cells in platelet adhesion was discussed. The flow conditions and hematocrit values were set to the same as corresponding experiments, and the numerical results were compared with the measurements. Numerical results show the number of platelets adhered on the wall is increased with the increase in hematocrit values. The number of adhered platelets estimated from the simulation was approximately 28 (per 0.01 square millimeter per minute) for the hematocrit value of 20%. These results agree well with the experimental results qualitatively and quantitatively, which proves the validity of the present numerical model including the interaction between fluid and many elastic bodies and the modeling of platelet adhesion. Numerical simulation also reproduces the behavior of red blood cells in the blood flow and their role in platelet adhesion. Red blood cells deform to a flat shape and move towards channel center region. In contrast, platelets are pushed out and have many chances to contact with the wall. As a result, the large number of adhered platelets is observed as hematocrit values becomes high. This result indicates the presence of red blood cells plays a crucial role in platelet adhesion.

  6. Cerebral blood flow in migraine and cortical spreading depression

    Energy Technology Data Exchange (ETDEWEB)

    Lauritzen, M.

    1987-01-01

    In a series of migraine patients, carotid arteriography was carried out as part of the clinical evalution. Nine patients developed a migrainous attack with focal neurological symptoms and headache after the angiography and during the subsequent, ongoing regional cerebral blood flow rCBF study. rCBF was measured by bolus injection of Xenon/sup 133/ into the internal carotid artery and a gamma camera with 254 collimated scintillation detectors covering the lateral aspect of the hemisphere. This technique depicts rCBF mainly at the level of the superficial cortex, with no depth resolution. The resolution is 1 cm/sup 2/ providing detailed spatial information of the cortical blood flow. Other methods for measuring local blood flow in animal and man employ a radioactive, freely diffusible tracer, in combination with an autoradiographic technique for the assessment of the tissue concentration, the so-called autoradiographic methods. In the series of patients with spontaneous migraine, rCBF was estimated using an in-vivo application of the autoradiographic principle. Xenon/sup 133/ was administered by inhalation and the time course of the arterial concentration curve was assessed by a scintillation detector over the upper right lung, since the arterial curve has been found to follow the shape of the lung curve. The rCBF was studied accompanying cortical spreading depression in rat experiments to evaluate wheter this phenomenon could explain the blood flow changes in migraine. (/sup 14/C) iodoantipyrine was given as an intravenous bolus injection and the brain content of indicator was determined by tissue sample or autoradiography after 10 or 20 seconds of isotope circulation. The conditions of the autoradiographic methods are that the flow remains constant within the period of measuring, and that the region under study is homogenous with regard to flow and lambda. (EG).

  7. Fractional flow reserve and resting indices for coronary physiologic assessment: Practical guide, tips, and tricks.

    Science.gov (United States)

    Picard, Fabien; Pighi, Michele; Ly, Hung Q

    2017-02-04

    Physiologic assessment using fractional flow reserve (FFR) to guide percutaneous coronary interventions (PCI) has been demonstrated to improve clinical outcomes, compared to angiography-guided PCI. Recently, resting indices such as resting Pd/Pa, "instantaneous wave-free ratio", and contrast medium induced FFR have been evaluated for the assessment of the functional consequences of coronary lesions. Herein, we review and discuss the use of FFR and other indices for the functional assessment of coronary lesions. This review will cover theoretical aspects, as well as practical points and common pitfalls related to coronary physiological assessment. © 2017 Wiley Periodicals, Inc.

  8. Assessment of maternal cerebral blood flow in patients with preeclampsia

    Directory of Open Access Journals (Sweden)

    Mandić Vesna

    2005-01-01

    Full Text Available Introduction Systemic vasoconstrktion in preeclamptic patients increases vascular resistance, and is manifested by increased arterial blood flow velocity. The aim of the study is to evaluate if there is a change of Doppler indices in maternal medial cerbral artery (MCA in severe preeclampsia due to: 1 severity of clinical symptoms, 2 the beginning of eclamptic attack and 3 the application of anticonvidsive therapy. Material and methods A prospective clinical study included 92 pregnant women, gestational age 28-36 weeks. They were divided into three groups: normotensive (n=30, mild preeclampsia (n=33, and severe preeclampsia (n=29. We investigated maternal cerebral circulation by assessing the MCA. We registrated: pulsatility index (Pi, resistance index (Ri, Systolic/diastolic ratio (S/D, and the maximum systolic, end diastolic and medium velocity. Patients with severe preeclampsia were divided into two subgroups: subgroup 1 included patients without symptoms of threatening eclampsia (n=18; 62.06%; while subgroup 2 included those with symptoms of preeclampsia (n=11; 37.94%. All patients with severe preeclampsia were treated with magnesium sulfate (MgSO4, and cerebral blood flow was measured before and after the treatment. Statistical analysis was done by oneway ANOVA, Student t-test and t-paired sample test. The difference was considered to be significant if p < 0.05. Results Significantly increased Pi, Ri and all velocities were established in the group of patients with severe preeclampsia compared with the other two groups. In the group with severe preeclamsia we registrated significantly increased values of all velocities (patients with signs of threatening eclampsia. After MgSO4 treatment in patients with severe preeclampsia significantly decreased values of Pi, Ri, S/D ratio and all velocities were registered. Discussion In the studied group of patients with severe preclampsia we found increased velocity values, Pi and Ri, especially in

  9. Skeletal blood flow, iliac histomorphometry, and strontium kinetics in osteoporosis: a relationship between blood flow and corrected apposition rate

    Energy Technology Data Exchange (ETDEWEB)

    Reeve, J.; Arlot, M.; Wootton, R.; Edouard, C.; Tellez, M.; Hesp, R.; Green, J.R.; Meunier, P.J.

    1988-06-01

    In 20 untreated patients with idiopathic or postmenopausal osteoporosis, kinetic studies of skeletal blood flow (using /sup 18/F) and bone turnover (using /sup 85/Sr) were combined with dynamic histomorphometry performed on transiliac biopsies taken within 6 weeks of each other. In 8 patients the combined studies were repeated after treatment. A further 5 patients were studied only while receiving treatment. As expected, skeletal blood flow measured by /sup 18/F correlated with an index of /sup 85/Sr uptake into the exchangeable pools of bone. Additionally and independently, skeletal blood flow correlated with an index of the work rate of the osteoblasts in each multicellular unit of bone (the corrected apposition rate of Parfitt). These correlations were statistically significant in both the untreated patients (P less than 0.05) and the whole group (P less than 0.001). Further indices related to bone turnover at the level of the skeleton as a whole were significantly associated with skeletal blood flow only in the combined group.

  10. Lattice Boltzmann Simulation of Blood Flow in Blood Vessels with the Rolling Massage

    Institute of Scientific and Technical Information of China (English)

    YI Hou-Hui; XU Shi-Xiong; QIAN Yue-Hong; FANG Hai-Ping

    2005-01-01

    @@ The rolling massage manipulation is a classic Chinese massage, which is expected to improve the circulation by pushing, pulling and kneading of the muscle. A model for the rolling massage manipulation is proposed and the lattice Boltzmann method is applied to study the blood flow in the blood vessels. The simulation results show that the blood flux is considerably modified by the rolling massage and the explicit value depends on the rolling frequency, the rolling depth, and the diameter of the vessel. The smaller the diameter of the blood vessel, the larger the enhancement of the blood flux by the rolling massage. The model, together with the simulation results,is expected to be helpful to understand the mechanism and further development of rolling massage techniques.

  11. Quantification of coronary flow reserve in patients with ischaemic and non-ischaemic cardiomyopathy and its association with clinical outcomes

    Science.gov (United States)

    Majmudar, Maulik D.; Murthy, Venkatesh L.; Shah, Ravi V.; Kolli, Swathy; Mousavi, Negareh; Foster, Courtney R.; Hainer, Jon; Blankstein, Ron; Dorbala, Sharmila; Sitek, Arkadiusz; Stevenson, Lynne W.; Mehra, Mandeep R.; Di Carli, Marcelo F.

    2015-01-01

    Aims Patients with left ventricular systolic dysfunction frequently show abnormal coronary vascular function, even in the absence of overt coronary artery disease. Moreover, the severity of vascular dysfunction might be related to the aetiology of cardiomyopathy. We sought to determine the incremental value of assessing coronary vascular dysfunction among patients with ischaemic (ICM) and non-ischaemic (NICM) cardiomyopathy at risk for adverse cardiovascular outcomes. Methods and results Coronary flow reserve (CFR, stress/rest myocardial blood flow) was quantified in 510 consecutive patients with rest left ventricular ejection fraction (LVEF) ≤45% referred for rest/stress myocardial perfusion PET imaging. The primary end point was a composite of major adverse cardiovascular events (MACE) including cardiac death, heart failure hospitalization, late revascularization, and aborted sudden cardiac death. Median follow-up was 8.2 months. Cox proportional hazards model was used to adjust for clinical variables. The annualized MACE rate was 26.3%. Patients in the lowest two tertiles of CFR (CFR ≤ 1.65) experienced higher MACE rates than those in the highest tertile (32.6 vs. 15.5% per year, respectively, P = 0.004), irrespective of aetiology of cardiomyopathy. Conclusion Impaired coronary vascular function, as assessed by reduced CFR by PET imaging, is common in patients with both ischaemic and non-ischaemic cardiomyopathy and is associated with MACE. PMID:25719181

  12. Quantitative relationship between coronary calcium content and coronary flow reserve as assessed by integrated PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Curillova, Zelmira [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); VA Boston Healthcare System, Division of Cardiology, Department of Medicine, West Roxbury, MA (United States); Yaman, Bettina F.; Sitek, Arkadius; El Fakhri, Georges [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Dorbala, Sharmila [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Kwong, Raymond Y. [Harvard Medical School, Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Anagnostopoulos, Constantinos [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Royal Brompton Hospital, Department of Nuclear Medicine, London (United Kingdom); Di Carli, Marcelo F. [Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Boston, MA (United States); Harvard Medical School, Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women' s Hospital, Boston, MA (United States); Brigham and Women' s Hospital, Noninvasive Cardiovascular Imaging Program, Departments of Medicine (Cardiology) and Radiology, Boston, MA (United States); Brigham and Women' s Hospital, Division of Nuclear Medicine and Molecular Imaging, Boston, MA (United States)

    2009-10-15

    To evaluate the relationship between coronary artery calcium (CAC) and coronary vasodilator function. We evaluated 136 patients without known coronary artery disease (CAD) undergoing vasodilator stress {sup 82}Rb PET/CT and CAC scoring who showed normal myocardial perfusion. The CAC score, resting and hyperemic myocardial blood flow (MBF), coronary flow reserve (CFR) and coronary vascular resistance were analyzed. Global and regional CAC scores showed significant but weak inverse correlations with hyperemic MBF (r=-0.31 and r=-0.26, p{<=}0.0002 respectively) and CFR (r=-0.28 and r=-0.2, p{<=}0.001 respectively). With increasing CAC score, there was a modest stepwise decline in CFR on a per-patient basis (1.8{+-}0.5 vs 1.7{+-}0.5 vs 1.5{+-}0.4, p=0.048, with total CAC=0, 1-400 and >400, respectively) and on a per-vessel basis. In multivariable modeling only body mass index and CAC score were predictive of CFR. In patients with an intermediate likelihood of, but without overt, CAD, there is a statistically significant but weak inverse correlation between CAC content and coronary vasodilator function. The strength of this association weakens after adjusting CAC scores for age, gender and coronary risk factors. This suggests that CAC and coronary vasodilator function provide biologically different information regarding atherosclerosis. (orig.)

  13. Assessment of endothelial function and myocardial flow reserve using {sup 15}O-water PET without attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Tuffier, Stephane; Joubert, Michael; Bailliez, Alban [EA 4650, Normandie Universite, Caen (France); Legallois, Damien [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Cardiology, Caen (France); Belin, Annette [Caen University Hospital, Department of Cardiac Surgery, Caen (France); Redonnet, Michel [Rouen University Hospital, Department of Cardiac Surgery, Rouen (France); Agostini, Denis [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Nuclear Medicine, Caen (France); Manrique, Alain [EA 4650, Normandie Universite, Caen (France); Caen University Hospital, Department of Nuclear Medicine, Caen (France); Cyceron PET Centre, Caen (France)

    2016-02-15

    Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of {sup 15}O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using {sup 15}O-water PET. We retrospectively processed 70 consecutive {sup 15}O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis. Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR. Non-attenuation-corrected {sup 15}O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population. (orig.)

  14. Subendocardial viability ratio as an index of impaired coronary flow reserve in hypertensives without significant coronary artery stenoses.

    Science.gov (United States)

    Tsiachris, D; Tsioufis, C; Syrseloudis, D; Roussos, D; Tatsis, I; Dimitriadis, K; Toutouzas, K; Tsiamis, E; Stefanadis, C

    2012-01-01

    Subendocardial viability ratio (SEVR), calculated through pulse wave analysis, is an index of myocardial oxygen supply and demand. Our aim was to evaluate the relationship between coronary flow reserve (CFR) and SEVR in 36 consecutive untreated hypertensives (aged 57.9 years, 12 males, all Caucasian) with indications of myocardial ischaemia and normal coronary arteries in coronary angiography. CFR was calculated by a 0.014-inch Doppler guidewire (Flowire, Volcano, San Diego, CA, USA) in response to bolus intracoronary administration of adenosine (30-60 μg). SEVR was calculated by radial applanation tonometry, while diastolic function was evaluated by means of transmitral flow and tissue Doppler imaging. Hypertensive patients with low CFR (n=24) compared with those with normal CFR (n=12) exhibited significantly decreased SEVR by 24.5% (P=0.002). In hypertensives with low CFR, CFR was correlated with SEVR (r=0.651, P=0.001). After applying multivariate linear regression analysis, age, left ventricular mass index, Em/Am, 24-h diastolic blood pressure (BP) and SEVR turned out to be the only independent predictors of CFR (adjusted R(2)=0.718). Estimation of SEVR by using applanation tonometry may provide a reliable tool for the assessment of coronary microcirculation in essential hypertensives with indications of myocardial ischaemia and normal coronary arteries.

  15. Echocardiographic and hemodynamic determinants of right coronary artery flow reserve and phasic flow pattern in advanced non-ischemic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Mady Charles

    2007-09-01

    Full Text Available Abstract Background In patients with advanced non-ischemic cardiomyopathy (NIC, right-sided cardiac disturbances has prognostic implications. Right coronary artery (RCA flow pattern and flow reserve (CFR are not well known in this setting. The purpose of this study was to assess, in human advanced NIC, the RCA phasic flow pattern and CFR, also under right-sided cardiac disturbances, and compare with left coronary circulation. As well as to investigate any correlation between the cardiac structural, mechanical and hemodynamic parameters with RCA phasic flow pattern or CFR. Methods Twenty four patients with dilated severe NIC were evaluated non-invasively, even by echocardiography, and also by cardiac catheterization, inclusive with Swan-Ganz catheter. Intracoronary Doppler (Flowire data was obtained in RCA and left anterior descendent coronary artery (LAD before and after adenosine. Resting RCA phasic pattern (diastolic/systolic was compared between subgroups with and without pulmonary hypertension, and with and without right ventricular (RV dysfunction; and also with LAD. RCA-CFR was compared with LAD, as well as in those subgroups. Pearson's correlation analysis was accomplished among echocardiographic (including LV fractional shortening, mass index, end systolic wall stress more hemodynamic parameters with RCA phasic flow pattern or RCA-CFR. Results LV fractional shortening and end diastolic diameter were 15.3 ± 3.5 % and 69.4 ± 12.2 mm. Resting RCA phasic pattern had no difference comparing subgroups with vs. without pulmonary hypertension (1.45 vs. 1.29, p = NS either with vs. without RV dysfunction (1.47 vs. 1.23, p = NS; RCA vs. LAD was 1.35 vs. 2.85 (p Conclusion In patients with chronic advanced NIC, RCA phasic flow pattern has a mild diastolic predominance, less marked than in LAD, with no effects from pulmonary artery hypertension or RV dysfunction. There is no significant correlation between any cardiac mechanical-structural or

  16. Structural analysis of red blood cell aggregates under shear flow.

    Science.gov (United States)

    Chesnutt, J K W; Marshall, J S

    2010-03-01

    A set of measures of red blood cell (RBC) aggregates are developed and applied to examine the aggregate structure under plane shear and channel flows. Some of these measures are based on averages over the set of red blood cells which are in contact with each other at a given time. Other measures are developed by first fitting an ellipse to the planar projection of the aggregate, and then examining the area and aspect ratio of the fit ellipse as well as the orientations of constituent RBCs with respect to the fit ellipse axes. The aggregate structural measures are illustrated using a new mesoscale computational model for blood cell transport, collision and adhesion. The sensitivity of this model to change in adhesive surface energy density and shear rate on the aggregate structure is examined. It is found that the mesoscale model predictions exhibit reasonable agreement with experimental and theoretical data for blood flow in plane shear and channel flows. The new structural measures are used to examine the differences between predictions of two- and three-dimensional computations of the aggregate formation, showing that two-dimensional computations retain some of the important aspects of three-dimensional computations.

  17. Laser speckle imaging of blood flow in microcirculation

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Haiying; Luo Qingming; Liu Qian; Lu Qiang; Gong Hui; Zeng Shaoqun [Key Laboratory of Biomedical Photonics of Ministry of Education of China, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2004-04-07

    Monitoring the spatio-temporal characteristics of microcirculation is crucial for studying the functional activities of biotissue and the mechanism of disease. However, conventional methods used to measure blood flow suffer from limited spatial resolution or the injection of exogenous substances or the need of scanning to obtain the dynamic of regional blood flow. Laser speckle imaging (LSI) technique makes up these disadvantages by obtaining the regional blood flow distribution with high spatio-temporal resolution without the need to scan. In this paper, LSI was introduced to investigate the dynamic responses of the rat mesenteric microcirculation to an incremental dose of phentolamine. The results showed that when the dose of phentolamine was less than 4 {mu}g ml{sup -1}, local application of phentolamine on the mesentery would increase the blood perfusion as the concentration increased. When the dose increased further, the improvement decreased. At a dose of 200 {mu}g ml{sup -1}, a microcirculation impediment was caused. At the same time, different responses between veinules and arterioles were manifested. These suggested that LSI is promising to be a useful contribution to drug development and testing.

  18. Ozone Therapy on Cerebral Blood Flow: A Preliminary Report

    Directory of Open Access Journals (Sweden)

    Bernardino Clavo

    2004-01-01

    Full Text Available Ozone therapy is currently being used in the treatment of ischemic disorders, but the underlying mechanisms that result in successful treatment are not well known. This study assesses the effect of ozone therapy on the blood flow in the middle cerebral and common carotid arteries. Seven subjects were recruited for the therapy that was performed by transfusing ozone-enriched autologous blood on 3 alternate days over 1 week. Blood flow quantification in the common carotid artery (n = 14 was performed using color Doppler. Systolic and diastolic velocities in the middle cerebral artery (n = 14 were estimated using transcranial Doppler. Ultrasound assessments were conducted at the following three time points: 1 basal (before ozone therapy, 2 after session #3 and 3 1 week after session #3. The common carotid blood flow had increased by 75% in relation to the baseline after session #3 (P < 0.001 and by 29% 1 week later (P = 0.039. In the middle cerebral artery, the systolic velocity had increased by 22% after session #3 (P = 0.001 and by 15% 1 week later (P = 0.035, whereas the diastolic velocity had increased by 33% after session #3 (P < 0.001 and by 18% 1 week later (P = 0.023. This preliminary Doppler study supports the clinical experience of achieving improvement by using ozone therapy in peripheral ischemic syndromes. Its potential use as a complementary treatment in cerebral low perfusion syndromes merits further clinical evaluation.

  19. Resistance exercise with different volumes: blood pressure response and forearm blood flow in the hypertensive elderly

    Science.gov (United States)

    Brito, Aline de Freitas; de Oliveira, Caio Victor Coutinho; Brasileiro-Santos, Maria do Socorro; Santos, Amilton da Cruz

    2014-01-01

    Background The purpose of this study was to evaluate the effect of two sessions of resistance exercise with different volumes on post-exercise hypotension, forearm blood flow, and forearm vascular resistance in hypertensive elderly subjects. Methods The study was conducted with ten hypertensive elderly (65±3 years, 28.7±3 kg/m2) subjected to three experimental sessions, ie, a control session, exercise with a set (S1), and exercise with three sets (S3). For each session, the subjects were evaluated before and after intervention. In the pre-intervention period, blood pressure, forearm blood flow, and forearm vascular resistance were measured after 10 minutes of rest in the supine position. Thereafter, the subjects were taken to the gym to perform their exercise sessions or remained at rest during the same time period. Both S1 and S3 comprised a set of ten repetitions of ten exercises, with an interval of 90 seconds between exercises. Subsequently, the measurements were again performed at 10, 30, 50, 70, and 90 minutes of recovery (post-intervention) in the supine position. Results Post-exercise hypotension was greater in S3 than in S1 (systolic blood pressure, −26.5±4.2 mmHg versus −17.9±4.7 mmHg; diastolic blood pressure, −13.8±4.9 mmHg versus −7.7±5 mmHg, P<0.05). Similarly, forearm blood flow and forearm vascular resistance changed significantly in both sessions with an increase and decrease, respectively, that was more evident in S3 than in S1 (P<0.05). Conclusion Resistance exercises with higher volume were more effective in causing post-exercise hypotension, being accompanied by an increase in forearm blood flow and a reduction of forearm vascular resistance. PMID:25540580

  20. A Reconstruction Method of Blood Flow Velocity in Left Ventricle Using Color Flow Ultrasound

    Directory of Open Access Journals (Sweden)

    Jaeseong Jang

    2015-01-01

    Full Text Available Vortex flow imaging is a relatively new medical imaging method for the dynamic visualization of intracardiac blood flow, a potentially useful index of cardiac dysfunction. A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color flow images compiled from ultrasound measurements. In this paper, a 2D incompressible Navier-Stokes equation with a mass source term is proposed to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. The boundary conditions to solve the system of equations are derived from the dimensions of the ventricle extracted from 2D echocardiography data. The performance of the proposed method is evaluated numerically using synthetic flow data acquired from simulating left ventricle flows. The numerical simulations show the feasibility and potential usefulness of the proposed method of reconstructing the intracardiac flow fields. Of particular note is the finding that the mass source term in the proposed model improves the reconstruction performance.

  1. Methods for blood flow measurements using ultrasound contrast agents

    Science.gov (United States)

    Fowlkes, J. Brian

    2003-10-01

    Blood flow measurements using ultrasound contrast agents are being investigated for myocardial perfusion and more recently in other organ systems. The methods are based largely on the relative increase in echogenicity due to the concentration of bubbles present in the ultrasound beam. In the simplest form, regional differences in blood volume can be inferred but the possibility exists to extract perfusion from the transit of contrast agent through tissue. Perfusion measurements rely on determining the flux of blood through a tissue volume and as such require knowledge of the fractional blood volume (FBV), i.e., ml blood/g tissue and the rate of exchange, commonly measured as the mean transit time (MTT). This presentation will discuss methods of determining each of these values and their combination to estimate tissue perfusion. Underlying principles of indicator-dilution theory will be provided in the context of ultrasound contrast agents. Current methods for determining MTT will include imaging of the intravenous bolus, in-plane contrast disruption with interval and real-time contrast recovery imaging, and control of contrast agent flow using arterial disruption (contrast interruption). The advantages and limitations of the methods will be examined along with current applications. [Work supported in part by NIH.

  2. Narcolepsy: regional cerebral blood flow during sleep and wakefulness

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, F.; Meyer, J.S.; Karacan, I.; Yamaguchi, F.; Yamamoto, M.

    1979-01-01

    Serial measurements of regional cerebral blood flow were made by the 135Xe inhalation method during the early stages of sleep and wakefulness in eight normal volunteers and 12 patients with narcolepsy. Electroencephalogram, electro-oculogram, and submental electromyogram were recorded simultaneously. In normals, mean hemispheric gray matter blood flow (Fg) during stages I and II sleep was significantly less than waking values. Maximum regional blood flow decreases during sleep occurred in the brainstem-cerebellar, right inferior temporal, and bilateral frontal regions. In patients with narcolepsy, mean hemispheric Fg while awake was 80.5 +- 13 ml per 100 gm brain per minute. During REM sleep, mean hemispheric Fg increased concurrently with large increases in brainstem-cerebellar region flow. During stages I and II sleep without REM, there were significant increases in mean hemispheric Fg and brainstem-cerebellar Fg, just the opposite of changes in normals. In narcolepsy, there appears to be a reversal of normal cerebral deactivation patterns, particularly involving the brainstem, during stages I and II sleep.

  3. Occlusion-free Blood Flow Animation with Wall Thickness Visualization.

    Science.gov (United States)

    Lawonn, Kai; Glaßer, Sylvia; Vilanova, Anna; Preim, Bernhard; Isenberg, Tobias

    2016-01-01

    We present the first visualization tool that combines pathlines from blood flow and wall thickness information. Our method uses illustrative techniques to provide occlusion-free visualization of the flow. We thus offer medical researchers an effective visual analysis tool for aneurysm treatment risk assessment. Such aneurysms bear a high risk of rupture and significant treatment-related risks. Therefore, to get a fully informed decision it is essential to both investigate the vessel morphology and the hemodynamic data. Ongoing research emphasizes the importance of analyzing the wall thickness in risk assessment. Our combination of blood flow visualization and wall thickness representation is a significant improvement for the exploration and analysis of aneurysms. As all presented information is spatially intertwined, occlusion problems occur. We solve these occlusion problems by dynamic cutaway surfaces. We combine this approach with a glyph-based blood flow representation and a visual mapping of wall thickness onto the vessel surface. We developed a GPU-based implementation of our visualizations which facilitates wall thickness analysis through real-time rendering and flexible interactive data exploration mechanisms. We designed our techniques in collaboration with domain experts, and we provide details about the evaluation of the technique and tool.

  4. Axial dispersion in flowing red blood cell suspensions

    Science.gov (United States)

    Podgorski, Thomas; Losserand, Sylvain; Coupier, Gwennou

    2016-11-01

    A key parameter in blood microcirculation is the transit time of red blood cells (RBCs) through an organ, which can influence the efficiency of gas exchange and oxygen availability. A large dispersion of this transit time is observed in vivo and is partly due to the axial dispersion in the flowing suspension. In the classic Taylor-Aris example of a solute flowing in a tube, the combination of molecular diffusion and parabolic velocity profile leads to enhanced axial dispersion. In suspensions of non-Brownian deformable bodies such as RBCs, axial dispersion is governed by a combination of shear induced migration and shear-induced diffusion arising from hydrodynamic interactions. We revisit this problem in the case of RBC pulses flowing in a microchannel and show that the axial dispersion of the pulse eventually saturates with a final extension that depends directly on RBC mechanical properties. The result is especially interesting in the dilute limit since the final pulse length depends only on the channel width, exponent of the migration law and dimensionless migration velocity. In continuous flow, the dispersion of transit times is the result of complex cell-cell and cell-wall interactions and is strongy influenced by the polydispersity of the blood sample. The authors acknowledge support from LabEx TEC21 and CNES.

  5. In vivo photoacoustic imaging of transverse blood flow using Doppler broadening of bandwidth

    OpenAIRE

    Yao, Junjie; Maslov, Konstantin I.; Shi, Yunfei; Taber, Larry A.; Lihong V. Wang

    2010-01-01

    A new method is proposed to measure transverse blood flow using photoacoustic Doppler broadening of bandwidth. By measuring bovine blood flowing through a plastic tube, the linear dependence of the broadening on the flow speed was validated. The blood flow of the microvasculature in a mouse ear and a chicken embryo (stage 16) was also studied.

  6. In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth

    OpenAIRE

    Yao, Junjie; Maslov, Konstantin I.; Shi, Yunfei; Taber, Larry A.; Lihong V. Wang

    2010-01-01

    A method is proposed to measure transverse blood flow by using photoacoustic Doppler broadening of bandwidth. By measuring bovine blood flowing through a plastic tube, the linear dependence of the broadening on the flow speed was validated. The blood flow of the microvasculature in a mouse ear and a chicken embryo (stage 16) was also studied.

  7. Transfer function analysis for the assessment of cerebral autoregulation using spontaneous oscillations in blood pressure and cerebral blood flow

    NARCIS (Netherlands)

    Abeelen, A.S.S. van den; Beek, A.H. van; Slump, C.H.; Panerai, R.B.; Claassen, J.A.H.R.

    2014-01-01

    Cerebral autoregulation (CA) is a key mechanism to protect the brain against excessive fluctuations in blood pressure (BP) and maintain cerebral blood flow. Analyzing the relationship between spontaneous BP and cerebral blood flow velocity (CBFV) using transfer function analysis is a widely used tec

  8. Anisodamine augments mucosal blood flow during gut ischemia/reperfusion

    Institute of Scientific and Technical Information of China (English)

    Hu Sen; Sheng Zhiyong

    2002-01-01

    Objective: To determine if anisodamine is able to augment mucosal perfusion during gut ischemia-reperfusion (I/R). Methods: A jejunal sac was formed in Sprague Dawley rat. A Laser Doppler probe and a tonometer were inserted into the sac which was filled with saline. The superior mesenteric artery was occluded (SMAO) for 60minutes followed by 90 minutes of reperfusion. At the end of 60 minutes of SMAO, either 0.2mg/kg of anisodmine or dobutamine was injected into the jejunal sac. Laser Doppler mucosal blood flow and regional PCO2 (PrCO2) measurements were made. Results: Mucosal blood flow was significantly increased at 30,60 and 90 minutes of reperfusion (R30, R60, R90 ) when intraluminal anisodamine or dobutamine was introduced compared to intraluminal saline only (44±3.3)% or (48±4.1)% vs. (37±2.6) % at R30, (57±5.0)% or (56±4.7)% vs. (45±2.7)% at R60, (64±3.3) % or (56 ± 4.2) % vs. (48 ± 3.4) % at R90 , respectively P<0.05). Blood flow changes were also reflected by lowering of jejunal PrCO2 measurements after intraluminal anisodamine or dobutamine compared with that of the saline controls (41±3. 1)mmHg or (44±3.0)mmHg vs. (49±3.7) mmHg at R30 , (38±3.7)mmHg or (40±2. 1)mmHg vs. (47±3.8) mmHgat R60, (34±2.1) mmHg or (39± 3.0) mmHg vs. (46±3.4) mmHg at R90, respectively,P<0. 05). The most interesting finding was that there were significantly higher mucosal blood flow and lower jejunal PrCO2 in anisodamine group than those in dobutamine group at 90 minutes of reperfusion (64± 3.3) %vs. (56±4.2)% for blood flow or (34 ± 2.1)mmHg vs. (39 ± 3.0)mmHg for PrCO2, respectively, P<0.05),suggesting that anisodamine had more lasting effect on mucosal perfusion than dobutamine. Conclusions:Intraluminal anisodamine can augment mucosal blood flow during gut I/R, and it may provide the protective effect on gut from ischemia and reperfusion injury.

  9. Blood Flow Imaging in Maternal and Fetal Arteries and Veins

    Science.gov (United States)

    Ricci, S.; Urban, G.; Vergani, P.; Paidas, M. J.; Tortoli, P.

    Maternal and fetal blood circulation has been investigated for nearly a decade through ultrasound (US) techniques. Evaluation of the spectrogram related to a single sample volume has been proven valuable for the assessment of fetal well-being and for prediction of pregnancy complications. In this work, an alternative technique, called Multigate Spectral Doppler Analysis (MSDA), is proposed. In this approach, 128 sample volumes aligned along the same scan line are simultaneously investigated to detect the blood velocity profile with high resolution. Profiles obtained through MSDA reveal features not detectable with the standard US technique, thus representing a more accurate flow signature. Some preliminary illustrative results are reported here.

  10. Sympathetic reflex control of blood flow in human peripheral tissues

    DEFF Research Database (Denmark)

    Henriksen, O

    1991-01-01

    Sympathetic vasoconstrictor reflexes are essential for the maintenance of arterial blood pressure in upright position. It has been generally believed that supraspinal sympathetic vasoconstrictor reflexes elicited by changes in baroreceptor activity play an important role. Recent studies on human...... sympathetic vasoconstrictor reflexes are blocked. Blood flow has been measure by the local 133Xe-technique. The results indicate the presence of spinal as well as supraspinal sympathetic vasoconstrictor reflexes to human peripheral tissues. Especially is emphasized the presence of a local sympathetic veno...

  11. Effect of pregnancy on regional cerebral blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Nagamachi, Shigeki; Hoshi, Hiroaki; Jinnouchi, Seishi; Ohnishi, Takashi; Futami, Shigemi; Watanabe, Katsushi; Ikeda, Tomoaki; Mori, Norimasa [Miyazaki Medical Coll., Kiyotake (Japan)

    1993-12-01

    Regional cerebral blood flow (r-CBF) of 10 pregnant women were quantified by {sup 133}Xe SPECT study with inhalation method before and after artificial abortion. During pregnancy, value of r-CBF in each region except occipital lobe was significantly higher than that of the post abortion. Arterial blood gas was analyzed after SPECT procedure. P{sub co2} concentration increased significantly after artificial abortion. Although its mechanism is unknown, our preliminary work demonstrates that r-CBF increased by pregnancy. (author).

  12. Holographic laser Doppler imaging of pulsatile blood flow

    CERN Document Server

    Bencteux, Jeffrey; Kostas, Thomas; Bayat, Sam; Atlan, Michael

    2015-01-01

    We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real-time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded optical signal was linked to local instantaneous out-of-plane motion of the skin at velocities of a few hundreds of microns per second, and compared to blood pulse monitored by plethysmoraphy during an occlusion-reperfusion experiment.

  13. Tomographic cerebral blood flow measurement during carotid surgery

    DEFF Research Database (Denmark)

    Rathenborg, Lisbet Knudsen; Vorstrup, Sidsel; Olsen, K S

    1994-01-01

    OBJECTIVES: The aim of the study was to depict regional cerebral blood flow (rCBF) during carotid cross clamping using 99mTechnetium-hexamethylpropylene amine oxime (TcHMPAO). This tracer rapidly passes the blood-brain barrier and is retained for hours in the brain tissue. Injecting TcHMPAO during...... RESULTS: We found a significant correlation between stump pressure and enhancement of side-to-side asymmetry in rCBF due to carotid cross clamping. Pronounced variations were seen in which regions were deprived of perfusion during clamping. CONCLUSION: TcHMPAO allows tomographic assessment of CBF during...

  14. Involvement of calcitonin gene-related peptide in migraine: regional cerebral blood flow and blood flow velocity in migraine patients

    DEFF Research Database (Denmark)

    Lassen, L.H.; Jacobsen, V.B.; Haderslev, P.A.

    2008-01-01

    g/min) or placebo for 20 min was studied in 12 patients with migraine without aura outside attacks. Xenon-133 inhalation SPECT-determined regional cerebral blood flow (rCBF) and transcranial Doppler (TCD)-determined blood velocity (V-mean) in the middle cerebral artery (MCA), as well as the heart......Calcitonin gene-related peptide (CGRP)-containing nerves are closely associated with cranial blood vessels. CGRP is the most potent vasodilator known in isolated cerebral blood vessels. CGRP can induce migraine attacks, and two selective CGRP receptor antagonists are effective in the treatment...... of migraine attacks. It is therefore important to investigate its mechanism of action in patients with migraine. We here investigate the effects of intravenous human alpha-CGRP (h alpha CGRP) on intracranial hemodynamics. In a double-blind, cross-over study, the effect of intravenous infusion of haCGRP (2 mu...

  15. Skin temperature and subcutaneous adipose blood flow in man

    DEFF Research Database (Denmark)

    Astrup, A; Bülow, J; Madsen, J

    1980-01-01

    The abdominal subcutaneous adipose tissue blood flow (ATBF) was measured bilaterally by the 133Xe washout method. At one side of the skin (epicutaneous) temperature was varied with a temperature blanket, the other side served as control. There was a significant (P less than 0.001) positive...... correlation between skin temperature and ATBF. In the range from 25 to 37 degrees CATBF increased 9% of the control flow on average per centigrade increase in skin temperature. ATBF at the control side was uninfluenced by the contralateral variations in skin temperature. Although no better correlation could...

  16. Case with stenosis of internal carotid artery detected as a region of decreased blood flow by Tc-99m HMPAO cerebral blood flow scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Hayashida, K.; Nishimura, T.; Uehara, T.; Imakita, S.; Yokota, I.; Ogura, H.; Oka, H.; Hayashi, M.; Kikuchi, H.

    1987-04-01

    Tc-99m hexamethylpropyleneamine oxime (= HMPAO) is expected to be an excellent agent as blood flow tracer of brain because it passes through blood brain barrier and is retained in brain parenchyma for several hours. Tc-99m HMPAO scintigraphy was applied to a patient complaining of transient ischemic attack without neurological findings. Left hemispheric hypoperfusion was detected by Tc-99m HMPAO cerebral blood flow scintigraphy. Although it was normal in CT and MRI, it was proved to be a 99 % stenosis of left internal carotid artery by digital subtraction angiography. Tc-99m HMPAO cerebral blood flow scintigraphy is useful for detecting abnormality of cerebral blood flow.

  17. Coronary Flow Velocity Reserve in Burn Injury: A Prospective Clinical Cohort Study.

    Science.gov (United States)

    Caliskan, Mustafa; Turk, Emin; Karagulle, Erdal; Ciftci, Ozgur; Oguz, Hakan; Kostek, Osman; Moray, Gokhan; Haberal, Mehmet

    2016-01-01

    The authors sought to evaluate coronary microvascular function and left ventricular diastolic dysfunction using transthoracic Doppler echocardiography in burn patients. In this study, 32 adult burn patients with partial or full-thickness scald burns that were hospitalized and treated were included. The control group was matched for age and sex and was composed of otherwise healthy volunteers. Transthoracic Doppler echocardiography examinations and simultaneous laboratory tests for cardiac evaluation were performed on the sixth month after burn injury as well as with the control group. High-sensitivity C-reactive protein levels were significantly higher in the burn patients than in controls (5.17 ± 3.86 vs 2.42 ± 1.78; P = .001). Lateral isovolumic relaxation time was significantly higher in the burn injury group than in the control group (92.7 ± 15.7 vs 85.5 ± 8.3; P = .03). Baseline coronary diastolic peak flow velocity of the left anterior descending artery was similar in both groups. However, hyperemic diastolic peak flow velocity and coronary flow velocity reserve (2.26 ± 0.48 vs 2.94 ± 0.47; P < .001) were significantly lower in the burn injury group than in the control group. Coronary flow velocity reserve was significantly and inversely correlated with high-sensitivity C-reactive protein, burn ratio, creatinine, and mitral A-wave max velocity. At the sixth month of treatment, burn patients had high-sensitivity C-reactive protein levels during this period, suggesting that inflammation still exists. In addition, subclinical coronary microvascular and left ventricular diastolic dysfunction can occur in burn patients without traditional cardiovascular risk factors. However, these results must be supported by additional studies.

  18. Pressure Gradient Estimation Based on Ultrasonic Blood Flow Measurement

    Science.gov (United States)

    Nitta, Naotaka; Homma, Kazuhiro; Shiina, Tsuyoshi

    2006-05-01

    Mechanical load to the blood vessel wall, such as shear stress and pressure, which occurs in blood flow dynamics, contribute greatly to plaque rupture in arteriosclerosis and to biochemical activation of endothelial cells. Therefore, noninvasive estimations of these mechanical loads are able to provide useful information for the prevention of vascular diseases. Although the pressure is the dominant component of mechanical load, for practical purposes, the pressure gradient is also often important. So far, we have investigated the estimation of the kinematic viscosity coefficient using a combination of the Navier-Stokes equations and ultrasonic velocity measurement. In this paper, a method for pressure gradient estimation using the estimated kinematic viscosity coefficient is proposed. The validity of the proposed method was investigated on the basis of the analysis with the data obtained by computer simulation and a flow phantom experiment. These results revealed that the proposed method can provide a valid estimation of the pressure gradient.

  19. Chronic intestinal ischemia and splanchnic blood-flow

    DEFF Research Database (Denmark)

    Zacho, Helle Damgaard; Henriksen, Jens Henrik; Abrahamsen, Jan

    2013-01-01

    -1390), and this value increased significantly to 1787 mL/min after the meal in healthy volunteers (P ...-induced increase in SBF was equal to 282 mL/min + 5.4 mL/min × bodyweight, (P = 0.025). The SO₂U in healthy volunteers and patients was 50.7 mL/min and 48.0 mL/min, respectively, and these values increased to 77.5 mL/min and 75 mL/min postprandially, respectively. Both baseline and postprandial SO₂U were directly......AIM: To determine the splanchnic blood flow and oxygen uptake in healthy-subjects and patients and to relate the findings to body-composition. METHODS: The total splanchnic blood flow (SBF) and oxygen uptake (SO₂U) were measured in 20 healthy volunteers (10 women) and 29 patients with suspected...

  20. Subcutaneous blood flow in early male pattern baldness

    Energy Technology Data Exchange (ETDEWEB)

    Klemp, P.; Peters, K.; Hansted, B.

    1989-05-01

    The subcutaneous blood flow (SBF) was measured by the /sup 133/Xe washout method in the scalp of 14 patients with early male pattern baldness. Control experiments were performed in 14 normal haired men matched for age. The SBF in the scalp of the normal individuals was about 10 times higher than previously reported SBF values in other anatomical regions. In patients with early male pattern baldness, SBF was 2.6 times lower than the values found in the normal individuals (13.7 +/- 9.6 vs 35.7 +/- 10.5 ml/100 g/min-1). This difference was statistically significant (p much less than 0.001). A reduced nutritive blood flow to the hair follicles might be a significant event in the pathogenesis of early male pattern baldness.

  1. Cerebral autoregulation control of blood flow in the brain

    CERN Document Server

    Payne, Stephen

    2016-01-01

    This Brief provides a comprehensive introduction to the control of blood flow in the brain. Beginning with the basic physiology of autoregulation, the author goes on to discuss measurement techniques, mathematical models, methods of analysis, and relevant clinical conditions, all within this single volume. The author draws together this disparate field, and lays the groundwork for future research directions. The text gives an up-to-date review of the state of the art in cerebral autoregulation, which is particularly relevant as cerebral autoregulation moves from the laboratory to the bedside. Cerebral Autoregulation will be useful to researchers in the physical sciences such as mathematical biology, medical physics, and biomedical engineering whose work is concerned with the brain. Researchers in the medical sciences and clinicians dealing with the brain and blood flow, as well as industry professionals developing techniques such as ultrasound, MRI, and CT will also find this Brief of interest.

  2. High speed optical holography of retinal blood flow.

    Science.gov (United States)

    Pellizzari, M; Simonutti, M; Degardin, J; Sahel, J-A; Fink, M; Paques, M; Atlan, M

    2016-08-01

    We performed noninvasive video imaging of retinal blood flow in a pigmented rat by holographic interferometry of near-infrared laser light backscattered by retinal tissue, beating against an off-axis reference beam sampled at a frame rate of 39 kHz with a high throughput camera. Local Doppler contrasts emerged from the envelopes of short-time Fourier transforms and the phase of autocorrelation functions of holograms rendered by Fresnel transformation. This approach permitted imaging of blood flow in large retinal vessels (∼30 microns diameter) over 400×400  pixels with a spatial resolution of ∼8 microns and a temporal resolution of ∼6.5  ms.

  3. Clitoral blood flow increases following vaginal pressure stimulation.

    Science.gov (United States)

    Lavoisier, P; Aloui, R; Schmidt, M H; Watrelot, A

    1995-02-01

    The vascular responses of clitoral arteries to vaginal pressure stimulation in 10 volunteer women were evaluated by Doppler ultrasonography. Pressure stimulations (20-160 mm Hg) along the lower third of the vagina increased blood velocity and flow into clitoral arteries in 9 of the 10 women. The latency and duration of the Doppler responses ranged from 0.1 to 1.6 sec and from 3.2 to 9.5 sec, respectively, and the response was associated with a blood flow increase of 4 to 11 times the baseline prestimulation level. This response parallels that recorded in the cavernous arteries in men when a similar range of pressure stimulations are applied to the glans penis. Similar responses evoked in the male and female suggest a sexual synergy that may occur during intercourse in that such physiological responses and reflexes may be reciprocally reinforced.

  4. Regional cerebral blood flow and vasoreactivity to acetazolamide in childhood moyamoya disease

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Hohkin, Kiyohiro; Kamiyama, Hiroyasu; Abe, Hiroshi [Hokkaido Univ., Sapporo (Japan). School of Medicine; Mitsumori, Kenji

    1995-04-01

    Using the 133-xenon inhalation method and single photon emission CT (SPECT), we measured regional cerebral blood flow (rCBF) and its reactivity to acetazolamide in 15 children with moyamoya disease (spontaneous occlusion of circle of Willis). In most of them, the mean hemispheric cerebral blood flow (mCBF) was similar to that of age-matched healthy children. However, their rCBF distribution was abnormal with low perfusion in the frontal and temporal lobes, and disturbed reactivity to acetazolamide in the frontal, temporal, and parietal lobes. After surgical revascularization of the anterior circulation with STA-MCA anastomosis and encephalo-duro-myo-anterio-sysnangiosis (EDAMS) these abnormal hemodynamics improved dramatically in the anterior circulation, including the frontal lobe. Postoperative SPECT studies revealed that cerebral vasodilatory capacity also improved in the occipital lobe and the basal ganglia. These results suggest that surgical revascularization of the anterior circulation should be carried out in order to improve cerebral hemodynamics as much as possible, especially in the frontal lobe, and it could also improve cerebral perfusion reserve in the posterior circulation. (author).

  5. Unsteady magnetohydrodynamic blood flow through irregular multi-stenosed arteries.

    Science.gov (United States)

    Mustapha, Norzieha; Amin, Norsarahaida; Chakravarty, Santabrata; Mandal, Prashanta Kumar

    2009-10-01

    Flow of an electrically conducting fluid characterizing blood through the arteries having irregular shaped multi-stenoses in the environment of a uniform transverse magnetic-field is analysed. The flow is considered to be axisymmetric with an outline of the irregular stenoses obtained from a three-dimensional casting of a mild stenosed artery, so that the physical problem becomes more realistic from the physiological point of view. The marker and cell (MAC) and successive-over-relaxation (SOR) methods are respectively used to solve the governing unsteady magnetohydrodynamic (MHD) equations and pressure-Poisson equation quantitatively and to observe the flow separation. The results obtained show that the flow separates mostly towards the downstream of the multi-stenoses. However, the flow separation region keeps on shrinking with the increasing intensity of the magnetic-field which completely disappears with sufficiently large value of the Hartmann number. The present observations certainly have some clinical implications relating to magnetotherapy which help reducing the complex flow separation zones causing flow disorder leading to the formation and progression of the arterial diseases.

  6. Effect of {beta}{sub 1} adrenergic receptor blockade on myocardial blood flow and vasodilatory capacity

    Energy Technology Data Exchange (ETDEWEB)

    Boettcher, M.; Czernin, J.; Sun, K. [Univ. of California, Los Angeles, CA (United States)] [and others

    1997-03-01

    The {beta}{sub 1} receptor blockade reduces cardiac work and may thereby lower myocardial blood flow (MBF) at rest. The effect of {beta}{sub 1} receptor blockade on hyperemic MBF is unknown. To evaluate the effect of selective {beta}{sub 1} receptor blockade on MBF at rest and during dipyridamole induced hyperemia, 10 healthy volunteers (8 men, 2 women, mean age 24 {+-} 5 yr) were studied using {sup 13}N-ammonia PET (two-compartment model) under control conditions and again during metoprolol (50 mg orally 12 hr and 1 hr before the study). The resting rate pressure product (6628 {+-} 504 versus 5225 {+-} 807) and heart rate (63 {+-} 6-54 {plus_minus} 5 bpm) declined during metoprolol (p < 0.05). Similarly, heart rate and rate pressure product declined from the baseline dipyridamole study to dipyridamole plus metoprolol (p < 0.05). Resting MBF declined in proportion to cardiac work by approximately 20% from 0.61 {+-} 0.09-0.51 {+-} 0.10 ml/g/min (p < 0.05). In contrast, hyperemic MBF increased when metoprolol was added to dipyridamole (1.86 {plus_minus} 0.27 {+-} 0.45 ml/g/min; p<0.05). The decrease in resting MBF together with the increase in hyperemic MBF resulted in a significant increase in the myocardial flow reserve during metoprolol (3.14 {+-} 0.80-4.61 {+-} 0.68; p<0.01). The {beta}{sub 1} receptor blockade increases coronary vasodilatory capacity and myocardial flow reserve. However, the mechanisms accounting for this finding remain uncertain. 32 refs., 2 figs., 2 tabs.

  7. Efficacy, Safety and Mechanisms of Blood Flow Restricted Exercise

    Science.gov (United States)

    Ploutz-Snyder, Lori

    2009-01-01

    This 20 minute talk will review studies in the peer-reviewed literature related to the effectiveness of blood flow restricted exercise as an exercise training program. There is controversy regarding the talk with cover the effectiveness of various exercise protocols and these differences will be compared and contrasted. Unpublished data from my laboratory at Syracuse University will be presented (see other abstract), as well as some unpublished work from the labs of Manini, Clark and Rasmussen (none are NASA funded).

  8. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  9. Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements - initial experience with a novel physician-driven algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Stefan [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University Medical Centre Mannheim (UMM), University of Heidelberg, First Department of Medicine, Faculty of Medicine Mannheim, Mannheim (Germany); Wang, Rui [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Beijing (China); Schoepf, U.J.; Steinberg, Daniel H.; Spearman, James V.; Bayer, Richard R. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Hamm, Christian W. [Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany); Renker, Matthias [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany)

    2015-04-01

    The present study aimed to determine the feasibility of a novel fractional flow reserve (FFR) algorithm based on coronary CT angiography (cCTA) that permits point-of-care assessment, without data transfer to core laboratories, for the evaluation of potentially ischemia-causing stenoses. To obtain CT-based FFR, anatomical coronary information and ventricular mass extracted from cCTA datasets were integrated with haemodynamic parameters. CT-based FFR was assessed for 36 coronary artery stenoses in 28 patients in a blinded fashion and compared to catheter-based FFR. Haemodynamically relevant stenoses were defined by an invasive FFR ≤0.80. Time was measured for the processing of each cCTA dataset and CT-based FFR computation. Assessment of cCTA image quality was performed using a 5-point scale. Mean total time for CT-based FFR determination was 51.9 ± 9.0 min. Per-vessel analysis for the identification of lesion-specific myocardial ischemia demonstrated good correlation (Pearson's product-moment r = 0.74, p < 0.0001) between the prototype CT-based FFR algorithm and invasive FFR. Subjective image quality analysis resulted in a median score of 4 (interquartile ranges, 3-4). Our initial data suggest that the CT-based FFR method for the detection of haemodynamically significant stenoses evaluated in the selected population correlates well with invasive FFR and renders time-efficient point-of-care assessment possible. (orig.)

  10. Blood flow distribution with adrenergic and histaminergic antagonists

    Energy Technology Data Exchange (ETDEWEB)

    Baker, C.H.; Davis, D.L.; Sutton, E.T.

    1989-03-01

    Superficial fibular nerve stimulation (SFNS) causes increased pre- and post-capillary resistances as well as increased capillary permeability in the dog hind paw. These responses indicate possible adrenergic and histaminergic interactions. The distribution of blood flow between capillaries and arteriovenous anastomoses (AVA) may depend on the relative effects of these neural inputs. Right hind paws of anesthetized heparinized dogs were vascularly and neurally isolated and perfused with controlled pressure. Blood flow distribution was calculated from the venous recovery of 85Sr-labeled microspheres (15 microns). The mean transit times of 131I-albumin and 85Sr-labeled microspheres were calculated. The effects of adrenergic and histaminergic antagonists with and without SFNS were determined. Phentolamine blocked the entire response to SFNS. Prazosin attenuated increases in total and AVA resistance. Yohimbine prevented increased total resistance, attenuated the AVA resistance increase, and revealed a decrease in capillary circuit resistance. Pyrilamine attenuated total resistance increase while SFNS increased capillary and AVA resistances. Metiamide had no effect on blood flow distribution with SFNS. The increase in AVA resistance with SFNS apparently resulted from a combination of alpha 1 and alpha 2 receptor stimulation but not histaminergic effects.

  11. Predicting Endometrium Receptivity with Parameters of Spiral Artery Blood Flow

    Institute of Scientific and Technical Information of China (English)

    GONG Xuehao; LI Quanshui; ZHANG Qingping; ZHU Guijin

    2005-01-01

    Summary: In order To evaluate whether the parameters of spiral artery blood flow, as measured by transvaginal color Doppler, may be used to assess endometrium receptivity prior to embryo transfer (ET), a retrospective study of 94 infertile women who had undergone ART treatments with different outcomes (pregnant or nonpregnant) was done. Subendometrial blood flow was evaluated. The resistance index (RI), systolic/diastolic ratio (S/D) and pulsatility index (PI) were significantly lower in those who achieved pregnancy as compared with those who did not: 0.62±0.04 vs 0.68±0.04 (P<0.001), 2.66±0.33 vs 3.19±0.39 (P<0.01) and 1.15±0.17 vs 1.34±0.22 (P<0.05), respectively. Furthermore, when RI>0.72, PI>1.6, and S/D>3.6, no pregnancy occurred. These data suggest that the parameters of spiral artery blood flow could be used as a new assay in predicting endometrial receptivity before ET.

  12. Ocular Blood Flow Measured Noninvasively in Zero Gravity

    Science.gov (United States)

    Ansari, Rafat R.; Manuel, Francis K.; Geiser, Martial; Moret, Fabrice; Messer, Russell K.; King, James F.; Suh, Kwang I.

    2003-01-01

    In spaceflight or a reduced-gravity environment, bodily fluids shift to the upper extremities of the body. The pressure inside the eye, or intraocular pressure, changes significantly. A significant number of astronauts report changes in visual acuity during orbital flight. To date this remains of unknown etiology. Could choroidal engorgement be the primary mechanism and a change in the curvature or shape of the cornea or lens be the secondary mechanism for this change in visual acuity? Perfused blood flow in the dense meshwork of capillaries of the choroidal tissue (see the preceding illustration) provides necessary nutrients to the outer layers of the retina (photoreceptors) to keep it healthy and maintain good vision. Unlike the vascular system, the choroid has no baroreceptors to autoregulate fluid shifts, so it can remain engorged, pushing the macula forward and causing a hyperopic (farsighted) shift of the eye. Experiments by researchers at the NASA Glenn Research Center could help answer this question and facilitate planning for long-duration missions. We are investigating the effects of zero gravity on the choroidal blood flow of volunteer subjects. This pilot project plans to determine if choroidal blood flow is autoregulated in a reduced-gravity environment.

  13. Pulsed photoacoustic Doppler flow measurements in blood-mimicking phantoms

    Science.gov (United States)

    Brunker, J.; Beard, P.

    2011-03-01

    The feasibility of making spatially resolved measurements of blood flow using pulsed photoacoustic Doppler techniques has been explored. Doppler time shifts were quantified via cross-correlation of pairs of photoacoustic waveforms generated within a blood-simulating phantom using pairs of laser light pulses. The photoacoustic waves were detected using a focussed or planar PZT ultrasound transducer. For each flow measurement, a series of 100 waveform pairs was collected. Previous data processing methods involved rejection of poorly correlated waveform pairs; the modal velocity value and standard deviation were then extracted from the selected distribution of velocity measurements. However, the data selection criteria used in this approach is to some extent arbitrary. A new data analysis protocol, which involves averaging the 100 cross-correlation functions and thus uses all of the measured data, has been designed in order to prevent exclusion of outliers. This more rigorous approach has proved effective for quantifying the linear motion of micron-scale absorbers imprinted on an acetate sheet moving with velocities in the range 0.14 to 1.25 ms-1. Experimental parameters, such as the time separation between the laser pulses and the transducer frequency response, were evaluated in terms of their effect on the accuracy, resolution and range of measurable velocities. The technique was subsequently applied to fluid phantoms flowing at rates less than 5 mms-1 along an optically transparent tube. Preliminary results are described for three different suspensions of phenolic resin microspheres, and also for whole blood. Velocity information was obtained even under non-optimal conditions using a low frequency transducer and a low pulse repetition frequency. The distinguishing advantage of pulsed rather than continuous-wave excitation is that spatially resolved velocity measurements can be made. This offers the prospect of mapping flow within the microcirculation and thus

  14. Fractional flow reserve versus angiography for guidance of PCI in patients with multivessel coronary artery disease (FAME)

    DEFF Research Database (Denmark)

    van Nunen, Lokien X; Zimmermann, Frederik M; Tonino, Pim A L

    2015-01-01

    BACKGROUND: In the Fractional Flow Reserve Versus Angiography for Multivessel Evaluation (FAME) study, fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) improved outcome compared with angiography-guided PCI for up to 2 years of follow-up. The aim in this study...... artery disease were randomly assigned to undergo angiography-guided PCI or FFR-guided PCI. Before randomisation, stenoses requiring PCI were identified on the angiogram. Patients allocated to angiography-guided PCI had revascularisation of all identified stenoses. Patients allocated to FFR-guided PCI had...

  15. Pooled comparison of regadenoson versus adenosine for measuring fractional flow reserve and coronary flow in the catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Stolker, Joshua M., E-mail: jstolker@yahoo.com [Mercy Heart and Vascular, 901 Patients First Drive, Washington, MO 63090 (United States); Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Lim, Michael J., E-mail: limmj@slu.edu [Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Shavelle, David M., E-mail: david.shavelle@med.usc.edu [University of Southern California, 1510 San Pablo St, Suite 322, Los Angeles, CA 90033 (United States); Morris, D. Lynn, E-mail: morrisdl@einstein.edu [Albert Einstein Medical Center, 5501 Old York Rd, Philadelphia, PA 19141 (United States); Angiolillo, Dominick J., E-mail: dominick.angiolillo@jax.ufl.edu [University of Florida Health-Jacksonville, 655 West 8th St, Jacksonville, FL 32209 (United States); Guzman, Luis A., E-mail: luis.guzman@jax.ufl.edu [University of Florida Health-Jacksonville, 655 West 8th St, Jacksonville, FL 32209 (United States); Kennedy, Kevin F., E-mail: kfkennedy@saint-lukes.org [Saint Luke' s Mid America Heart Institute, 4401 Wornall Road, Kansas City, MO 64111 (United States); Weber, Elizabeth, E-mail: eweber1@slu.edu [Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Zareh, Meena, E-mail: meena.zareh@med.usc.edu [University of Southern California, 1510 San Pablo St, Suite 322, Los Angeles, CA 90033 (United States); Neumayr, Robert H., E-mail: robneumayr@gmail.com [Mercy Heart and Vascular, 901 Patients First Drive, Washington, MO 63090 (United States); Saint Louis University, 3635 Vista Ave, St. Louis, MO 63110 (United States); Zenni, Martin M., E-mail: martin.zenni@jax.ufl.edu [University of Florida Health-Jacksonville, 655 West 8th St, Jacksonville, FL 32209 (United States)

    2015-07-15

    Background: Adenosine is the gold standard for augmenting coronary flow during fractional flow reserve (FFR) testing of intermediate coronary stenoses. However, intravenous infusion is time-consuming and intracoronary injection is subject to variability. Regadenoson is a newer adenosine alternative administered as a single intravenous bolus during nuclear stress testing, but its efficacy and safety during FFR testing have been evaluated only in small, single-center studies. Methods: We pooled data from 5 academic hospitals, in which patients undergoing clinically-indicated FFR prospectively underwent comparison of intravenous adenosine infusion (140–175 mcg/kg/min) versus regadenoson bolus (400 mcg). Hemodynamics and symptoms with adenosine were recorded until maximal hyperemia occurred, and after returning to baseline hemodynamics, regadenoson was administered and monitoring was repeated. In a subset of patients with coronary flow data, average peak velocity (APV) at the distal flow sensor was recorded. Results: Of 149 patients enrolled, mean age was 59 ± 9 years, 76% were male, and 54% underwent testing of the left anterior descending artery. Mean adenosine-FFR and regadenoson-FFR were identical (0.82 ± 0.10) with excellent correlation of individual values (r = 0.96, p < 0.001) and no difference in patient-reported symptoms. Four patients (2.6%) had discrepancies between the 2 drugs for the clinical decision-making cutoff of FFR ≤ 0.80. Coronary flow responses to adenosine and regadenoson were similar (APV at maximal hyperemia 36 cm/s for both, p = 0.81). Conclusions: Regadenoson single-bolus administration has comparable FFR, symptoms, and coronary flow augmentation when compared with standard intravenous adenosine infusion. With its greater ease of administration, regadenoson may be a more “user-friendly” option for invasive ischemic testing.

  16. Rotating permanent magnet excitation for blood flow measurement.

    Science.gov (United States)

    Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S

    2015-11-01

    A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

  17. Relationship between cardiac function and resting cerebral blood flow

    DEFF Research Database (Denmark)

    Henriksen, Otto M; Jensen, Lars T; Krabbe, Katja;

    2014-01-01

    Although both impaired cardiac function and reduced cerebral blood flow are associated with ageing, current knowledge of the influence of cardiac function on resting cerebral blood flow (CBF) is limited. The aim of this study was to investigate the potential effects of cardiac function on CBF. CBF...... and cardiac output were measured in 31 healthy subjects 50-75 years old using magnetic resonance imaging techniques. Mean values of CBF, cardiac output and cardiac index were 43.6 ml per 100 g min(-1), 5.5 l min(-1) and 2.7 l min(-1) m(-2), respectively, in males, and 53.4 ml per 100 g min(-1), 4.3 l min(-1......) and 2.4 l min(-1) m(-2), respectively, in females. No effects of cardiac output or cardiac index on CBF or structural signs of brain ageing were observed. However, fractional brain flow defined as the ratio of total brain flow to cardiac output was inversely correlated with cardiac index (r(2) = 0.22, P...

  18. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C;

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...... that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein......., corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...

  19. Laser speckle contrast imaging to measure changes in cerebral blood flow.

    Science.gov (United States)

    Winship, Ian R

    2014-01-01

    Laser speckle contrast imaging (LSCI) is a powerful tool capable of acquiring detailed maps of blood flow in arteries and veins on the cortical surface. Based on the blurring of laser speckle patterns by the motion of blood cells, LSCI can be combined with a variety of optical imaging preparations to acquire high-spatiotemporal resolution images of blood flow, and track changes in blood flow over time, using relatively simple instrumentation. Here, we describe methods for LSCI of cerebral blood flow via a thin skull imaging preparation in mice or rats. This preparation allows precise semiquantitative mapping of changes in blood flow over time using straightforward surgical protocols and equipment.

  20. PERFUSION PRESSURE AND RENAL BLOOD FLOW: THEIR RELATIONSHIP AND DIFFERENCES

    Directory of Open Access Journals (Sweden)

    Carlos G. Musso, MD. PhD.1,2, Manuel Vilas, MD.

    2014-05-01

    Full Text Available The concepts of renal perfusion pressure (RPP and renal blood flow (RBF are usually confused, but although they are intimately related, they are not strictly the same. RPP originates from the minute cardiac volume and is, therefore, the cause of RBF, which generates glomerular filtration and as a consequence, also induces the urinary flow. On the other hand, whereas RPP can be subject to fluctuations, the same happens to RBF though at a much lower level due to the existence of physiological mechanisms, such as self-regulation of the flow and tubule-glomerular feed-back. We conclude that there is a dependence of the RBF in relation with RPP, with the former acting as the final responsible of the glomerular filtration.

  1. Renal blood flow and metabolism after cold ischaemia

    DEFF Research Database (Denmark)

    Henriksen, J H; Petersen, H K

    1984-01-01

    Peroperative measurements of renal blood flow (RBF), renal O2-uptake, and renal venous lactate/pyruvate (L/P) ratio were performed before and after a period of 30-71 min of hypothermic (10-15 degrees C) renal ischaemia in nine patients, undergoing surgery for renal calculi. Before ischaemia, RBF.......01) immediately after re-established perfusion and 36% (P less than 0.02) 30 min later. In one additional patient, who had a short warm ischaemia (8 min), the flow pattern was the same. As arterial pressure remained constant, the reduced RBF signifies an increased renal vascular resistance. Renal O2-uptake...... and renal venous L/P ratio were almost constant, indicating no significant anaerobic processes being involved in the flow response. None of the patients showed any signs of reactive hyperaemia. It is concluded that hypothermic renal ischaemia may be followed by an increased renal vascular resistance even...

  2. A model of blood flow in the mesenteric arterial system

    Directory of Open Access Journals (Sweden)

    Cheng Leo K

    2007-05-01

    Full Text Available Abstract Background There are some early clinical indicators of cardiac ischemia, most notably a change in a person's electrocardiogram. Less well understood, but potentially just as dangerous, is ischemia that develops in the gastrointestinal system. Such ischemia is difficult to diagnose without angiography (an invasive and time-consuming procedure mainly due to the highly unspecific nature of the disease. Understanding how perfusion is affected during ischemic conditions can be a useful clinical tool which can help clinicians during the diagnosis process. As a first step towards this final goal, a computational model of the gastrointestinal system has been developed and used to simulate realistic blood flow during normal conditions. Methods An anatomically and biophysically based model of the major mesenteric arteries has been developed to be used to simulate normal blood flows. The computational mesh used for the simulations has been generated using data from the Visible Human project. The 3D Navier-Stokes equations that govern flow within this mesh have been simplified to an efficient 1D scheme. This scheme, together with a constitutive pressure-radius relationship, has been solved numerically for pressure, vessel radius and velocity for the entire mesenteric arterial network. Results The computational model developed shows close agreement with physiologically realistic geometries other researchers have recorded in vivo. Using this model as a framework, results were analyzed for the four distinct phases of the cardiac cycle – diastole, isovolumic contraction, ejection and isovolumic relaxation. Profiles showing the temporally varying pressure and velocity for a periodic input varying between 10.2 kPa (77 mmHg and 14.6 kPa (110 mmHg at the abdominal aorta are presented. An analytical solution has been developed to model blood flow in tapering vessels and when compared with the numerical solution, showed excellent agreement. Conclusion An

  3. Resistance exercise with different volumes: blood pressure response and forearm blood flow in the hypertensive elderly

    Directory of Open Access Journals (Sweden)

    Brito AF

    2014-12-01

    Full Text Available Aline de Freitas Brito,1 Caio Victor Coutinho de Oliveira,2 Maria do Socorro Brasileiro-Santos,1 Amilton da Cruz Santos1 1Physical Education Department, 2Research Laboratory for Physical Training Applied to Performance and Health, Federal University of Paraíba, João Pessoa, Brazil Background: The purpose of this study was to evaluate the effect of two sessions of resistance exercise with different volumes on post-exercise hypotension, forearm blood flow, and forearm vascular resistance in hypertensive elderly subjects.Methods: The study was conducted with ten hypertensive elderly (65±3 years, 28.7±3 kg/m2 subjected to three experimental sessions, ie, a control session, exercise with a set (S1, and exercise with three sets (S3. For each session, the subjects were evaluated before and after intervention. In the pre-intervention period, blood pressure, forearm blood flow, and forearm vascular resistance were measured after 10 minutes of rest in the supine position. Thereafter, the subjects were taken to the gym to perform their exercise sessions or remained at rest during the same time period. Both S1 and S3 comprised a set of ten repetitions of ten exercises, with an interval of 90 seconds between exercises. Subsequently, the measurements were again performed at 10, 30, 50, 70, and 90 minutes of recovery (post-intervention in the supine position.Results: Post-exercise hypotension was greater in S3 than in S1 (systolic blood pressure, −26.5±4.2 mmHg versus −17.9±4.7 mmHg; diastolic blood pressure, −13.8±4.9 mmHg versus −7.7±5 mmHg, P<0.05. Similarly, forearm blood flow and forearm vascular resistance changed significantly in both sessions with an increase and decrease, respectively, that was more evident in S3 than in S1 (P<0.05.Conclusion: Resistance exercises with higher volume were more effective in causing post-exercise hypotension, being accompanied by an increase in forearm blood flow and a reduction of forearm vascular

  4. Fetal blood flow measurements in severe rhesus isoimmunization. A case report.

    Science.gov (United States)

    Stiller, R J; Ashmead, G G; Paul, D; Weiner, S

    1987-06-01

    Maternal isoimmunization can result in fetal anemia. Current management of isoimmunized pregnancies involves amniocentesis and spectrophotometry. Pulsed Doppler ultrasound can provide fetal blood flow determinations from the fetal umbilical vein. A pregnancy complicated by severe rhesus isoimmunization was studied with Doppler ultrasound. Increased fetal umbilical blood flow was associated with increased fetal hemolysis. Umbilical vein blood flow decreased after intrauterine transfusion. Doppler ultrasound assessment of fetal blood flow is a useful noninvasive adjunct in isoimmunized pregnancies.

  5. Invasive and non-invasive fractional flow reserve index in validation of hemodynamic severity of intracoronary lesions.

    Science.gov (United States)

    Wasilewski, Jarosław; Mirota, Kryspin; Hawranek, Michał; Poloński, Lech

    2013-01-01

    This review discusses visual and functional evaluation of the hemodynamic significance of the degree of stenosis in coronary angiography, with respect to the indications for revascularization. The concept of the coronary flow reserve is defined, and the theoretical assumptions of the invasive measurement of the fractional flow reserve (FFR) are presented. In the following part, the publication describes the basic steps of numerical stimulations in terms of computational fluid dynamics (CFD) in calculating the fractional flow reserve based on computed tomography (CT) coronary angiography (FFRCT). The numerical FFRCT estimation in correlation with invasive measurements, as well as benefits deriving from FFRCT in the diagnosis of coronary artery disease, is presented in the example of the multicentre prospective DISCOVER-FLOW trial and the DeFACTO project. The CDF method enables to obtain hemodynamic significance of stenosis solely from the coronary anatomy vizualized by CT angiography. The calculation of FFRCT increases the diagnostic reliability of coronary flow reserve estimations. It contributes to the improvement in patients' qualification for contrast coronarography. If the accuracy of FFRCT is confirmed in clinical practice, and the time required for computational processing is shortened, it may turn out that the algorithms of coronary heart disease diagnosis will be verified and it will be to a greater extent based on the CT results.

  6. 军队血站战备血液的储备管理%Blood Reserves Management for Combat Readiness in Military Blood Station

    Institute of Scientific and Technical Information of China (English)

    任红; 张立福; 穆林; 张玉婷; 李晓倩; 赵凯

    2014-01-01

    为适应新形势下血液战备保障需要,本文从加强领导、培养人才、拓宽渠道、规范管理等方面,总结军队血站战备血液储备的经验做法,对军队血站战备血液储备工作具有借鉴作用。%To adapt to the new situation of blood readiness support needs , the article summarized the main experiences and practices from strengthen leadership , personnel training , expand the channels , standardized man-agement , so as to improve the blood reserves work for combat readiness in military blood station .

  7. ASSESSMENT OF VERTEBRAL ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES IN COMPARISON WITH INTERNAL AND COMMON CAROTID ARTERIES BLOOD FLOW SPECTRAL DOPPLER INDICES

    Directory of Open Access Journals (Sweden)

    H. Mazaher

    2007-05-01

    Full Text Available Vertebrobasilar insufficiency is the cause of cerebrovascular accidents in 20% of cases. There are few reports regarding spectral Doppler indices (SDIs of vertebral arteries (VAs normal blood flow. The objective of this study was to provide basic reference data about SDIs of VAs normal blood flow separately and in comparison with internal carotid arteries (ICAs and common carotid arteries (CCAs normal blood flows SDIs. This cross-sectional study performed on 70 normal patients. Color Doppler sonography (CDS and spectral Doppler sonography (SDS of right and left VAs (RVA and LVA, right and left CCAs (RCCA and LCCA, right and left ICAs (RICA and LICA, were performed. The mean PSV, EDV, and RI values of RVA blood flow were as 41.60 ± 9.6 cm/s, 14.60 ± 3.7 cm/s and 0.65 ± 0.06, and the mean PSV, EDV and RI values of LVA blood flow were as 42.20 ± 10.2 cm/s, 15.20 ± 4.2 cm/s, and 0.64 ± 0.05, respectively. There was not statistically significant difference between the mean PSV, EDV and RI values of RVA and LVA blood flows. The mean PSV and EDV values of VAs blood flows were significantly lower than the values of CCAs and ICCAs blood flows, respectively. The mean RI value of VAs blood flows was significantly lower than the mean RI Value of CCAs blood flows, but there was not statistically significant difference between the mean RI value of VAs blood flows and the mean RI value of ICAs blood flows.

  8. Cerebral blood flow assessment of preterm infants during respiratory therapy with the expiratory flow increase technique

    Directory of Open Access Journals (Sweden)

    Mariana Almada Bassani

    2016-06-01

    Full Text Available Abstract Objective: To assess the impact of respiratory therapy with the expiratory flow increase technique on cerebral hemodynamics of premature newborns. Methods: This is an intervention study, which included 40 preterm infants (≤34 weeks aged 8-15 days of life, clinically stable in ambient air or oxygen catheter use. Children with heart defects, diagnosis of brain lesion and/or those using vasoactive drugs were excluded. Ultrasonographic assessments with transcranial Doppler flowmetry were performed before, during and after the increase in expiratory flow session, which lasted 5min. Cerebral blood flow velocity and resistance and pulsatility indices in the pericallosal artery were assessed. Results: Respiratory physical therapy did not significantly alter flow velocity at the systolic peak (p=0.50, the end diastolic flow velocity (p=0.17, the mean flow velocity (p=0.07, the resistance index (p=0.41 and the pulsatility index (p=0.67 over time. Conclusions: The expiratory flow increase technique did not affect cerebral blood flow in clinically-stable preterm infants.

  9. Mucosal/submucosal blood flow in the gut wall determined by local washout of 133Xenon

    DEFF Research Database (Denmark)

    Mortensen, Peter; Olsen, J; Bülow, J

    1991-01-01

    the initial slope of the washout was used for measuring blood flow rate. Blood flow rate was simultaneously measured by microsphere entrapment technique. There was an excellent correlation between the blood flow rate determined by the two techniques the correlation coefficient R being 0.89 in the small...

  10. Numerical Simulations of Blood Flows in the Left Atrium

    Science.gov (United States)

    Zhang, Lucy

    2008-11-01

    A novel numerical technique of solving complex fluid-structure interactions for biomedical applications is introduced. The method is validated through rigorous convergence and accuracy tests. In this study, the technique is specifically used to study blood flows in the left atrium, one of the four chambers in the heart. Stable solutions are obtained at physiologic Reynolds numbers by applying pulmonary venous inflow, mitral valve outflow and appropriate constitutive equations to closely mimic the behaviors of biomaterials. Atrial contraction is also implemented as a time-dependent boundary condition to realistically describe the atrial wall muscle movements, thus producing accurate interactions with the surrounding blood. From our study, the transmitral velocity, filling/emptying velocity ratio, durations and strengths of vortices are captured numerically for sinus rhythms (healthy heart beat) and they compare quite well with reported clinical studies. The solution technique can be further used to study heart diseases such as the atrial fibrillation, thrombus formation in the chamber and their corresponding effects in blood flows.

  11. Tracking flow of leukocytes in blood for drug analysis

    Science.gov (United States)

    Basharat, Arslan; Turner, Wesley; Stephens, Gillian; Badillo, Benjamin; Lumpkin, Rick; Andre, Patrick; Perera, Amitha

    2011-03-01

    Modern microscopy techniques allow imaging of circulating blood components under vascular flow conditions. The resulting video sequences provide unique insights into the behavior of blood cells within the vasculature and can be used as a method to monitor and quantitate the recruitment of inflammatory cells at sites of vascular injury/ inflammation and potentially serve as a pharmacodynamic biomarker, helping screen new therapies and individualize dose and combinations of drugs. However, manual analysis of these video sequences is intractable, requiring hours per 400 second video clip. In this paper, we present an automated technique to analyze the behavior and recruitment of human leukocytes in whole blood under physiological conditions of shear through a simple multi-channel fluorescence microscope in real-time. This technique detects and tracks the recruitment of leukocytes to a bioactive surface coated on a flow chamber. Rolling cells (cells which partially bind to the bioactive matrix) are detected counted, and have their velocity measured and graphed. The challenges here include: high cell density, appearance similarity, and low (1Hz) frame rate. Our approach performs frame differencing based motion segmentation, track initialization and online tracking of individual leukocytes.

  12. Blood pressure and blood flow variation during postural change from sitting to standing: model development and validation

    DEFF Research Database (Denmark)

    Olufsen, M.S.; Ottesen, Johnny T.; Tran, H.T.

    2005-01-01

    Short-term cardiovascular responses to postural change from sitting to standing involve complex interactions between the autonomic nervous system, which regulates blood pressure, and cerebral autoregulation, which maintains cerebral perfusion. We present a mathematical model that can predict...... dynamic changes in beat-to-beat arterial blood pressure and middle cerebral artery blood flow velocity during postural change from sitting to standing. Our cardiovascular model utilizes 11 compartments to describe blood pressure, blood flow, compliance, and resistance in the heart and systemic circulation....... To include dynamics due to the pulsatile nature of blood pressure and blood flow, resistances in the large systemic arteries are modeled using nonlinear functions of pressure. A physiologically based submodel is used to describe effects of gravity on venous blood pooling during postural change. Two types...

  13. Form, shape and function: segmented blood flow in the choriocapillaris

    Science.gov (United States)

    Zouache, M. A.; Eames, I.; Klettner, C. A.; Luthert, P. J.

    2016-10-01

    The development of fluid transport systems was a key event in the evolution of animals and plants. While within vertebrates branched geometries predominate, the choriocapillaris, which is the microvascular bed that is responsible for the maintenance of the outer retina, has evolved a planar topology. Here we examine the flow and mass transfer properties associated with this unusual geometry. We show that as a result of the form of the choriocapillaris, the blood flow is decomposed into a tessellation of functional vascular segments of various shapes delineated by separation surfaces across which there is no flow, and in the vicinity of which the transport of passive substances is diffusion-limited. The shape of each functional segment is determined by the distribution of arterioles and venules and their respective relative flow rates. We also show that, remarkably, the mass exchange with the outer retina is a function of the shape of each functional segment. In addition to introducing a novel framework in which the structure and function of the metabolite delivery system to the outer retina may be investigated in health and disease, the present work provides a general characterisation of the flow and transfers in multipole Hele-Shaw configurations.

  14. Laser Doppler flowmetry for bone blood flow measurement: correlation with microsphere estimates and evaluation of the effect of intracapsular pressure on femoral head blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Swiontkowski, M.F.; Tepic, S.; Perren, S.M.; Moor, R.; Ganz, R.; Rahn, B.A.

    1986-01-01

    Laser Doppler flowmetry (LDF) was used to measure bone blood flow in the rabbit femoral condyles. To correlate the LDF output signal blood cell flux to in vivo blood flow, simultaneous measurements using LDF and /sup 85/Sr-labeled microspheres were made in an adult rabbit model. There was no correlation between the two methods for blood flow in the femoral condyles and the correlation between the two methods for blood flow in the femoral head does not achieve statistical significance. An LDF signal of 0.4 V was approximately equal to a microsphere measured flow rate of 0.4 ml blood/g bone/min. The strength of the correlation in the latter case may have been affected by (a) large arteriovenous shunts, (b) inadequate mixing of the microspheres with a left ventricular injection, and (c) insufficient numbers of microspheres present in the bone samples. When LDF was used to evaluate the effect of elevated intracapsular pressure on femoral head blood flow in skeletally mature rabbits, femoral head subchondral bone blood flow declined with increasing intracapsular pressure from a baseline value of 0.343 +/- 0.036 to a value of 0.127 +/- 0.27 at 120 cm of water pressure. The decline in femoral head blood flow was statistically significant at pressures of 40 cm of water or higher (p less than 0.001), and evaluation of sections of the proximal femora made from preterminal disulphine blue injections confirmed these findings. Intracapsular tamponade has an adverse effect on femoral head blood flow beginning well below central venous pressure and should be considered in the pathophysiology of posttraumatic and nontraumatic necrosis of the femoral head. Laser Doppler flowmetry was easy to use and appears to be a reproducible technique for evaluating femoral head blood flow, offering distinct advantages over the microsphere technique for measuring bone blood flow.

  15. Physiologic assessment of coronary artery disease: Focus on fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Do Yeon; Koo, Bon Kwon [Dept. of Radiology, Internal Medicine and Cardiovascular Center, Seoul National University Hospital, Seoul (Korea, Republic of); Lee, Joo Myung [Dept. of Internal Medicine and Cardiovascular Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2016-06-15

    The presence of myocardial ischemia is the most important prognostic factor in patients with ischemic heart disease. Fractional flow reserve (FFR) is a gold standard invasive method used to detect the stenosis-specific myocardial ischemia. FFR-guided revascularization strategy is superior to angiography-guided strategy. The recently developed hyperemia-free index, instantaneous wave free ratio is being actively investigated. A non-invasive FFR derived from coronary CT angiography is now used in clinical practice. Due to rapid expansion of invasive and non-invasive physiologic assessment, comprehensive understanding of the role and potential pitfalls of each modality are required for its application. In this review, we focus on the basic and clinical aspects of physiologic assessment in ischemic heart disease.

  16. Noninvasive Fractional Flow Reserve for the Diagnosis of Lesion-specific Ischemia: A Case Example

    Directory of Open Access Journals (Sweden)

    Jesper Møller Jensen

    2015-01-01

    Full Text Available A physically active 52-year-old male with atypical chest pain was referred to our department. A coronary computed tomography angiography (CCTA showed a stenotic plaque in the mid left anterior descending coronary artery (LAD. A rest-stress Rubidium-82 myocardial perfusion was normal. One year later the patient sustained a cardiac arrest and percutaneous coronary intervention of the mid-LAD was successfully performed. The original CCTA data were submitted for noninvasive determination of fractional flow reserve (FFR CT revealing an ischemia-producing lesion in the mid-LAD. This case demonstrates the inherent limitations of assessing lesion-specific ischemia. FFR CT shows promise as a new method for future selection of patients for coronary angiography.

  17. Physiologic Assessment of Coronary Artery Disease: Focus on Fractional Flow Reserve.

    Science.gov (United States)

    Hwang, Doyeon; Lee, Joo Myung; Koo, Bon-Kwon

    2016-01-01

    The presence of myocardial ischemia is the most important prognostic factor in patients with ischemic heart disease. Fractional flow reserve (FFR) is a gold standard invasive method used to detect the stenosis-specific myocardial ischemia. FFR-guided revascularization strategy is superior to angiography-guided strategy. The recently developed hyperemia-free index, instantaneous wave free ratio is being actively investigated. A non-invasive FFR derived from coronary CT angiography is now used in clinical practice. Due to rapid expansion of invasive and non-invasive physiologic assessment, comprehensive understanding of the role and potential pitfalls of each modality are required for its application. In this review, we focus on the basic and clinical aspects of physiologic assessment in ischemic heart disease.

  18. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  19. Theoretical model of blood flow measurement by diffuse correlation spectroscopy

    Science.gov (United States)

    Sakadžić, Sava; Boas, David A.; Carp, Stefan

    2017-02-01

    Diffuse correlation spectroscopy (DCS) is a noninvasive method to quantify tissue perfusion from measurements of the intensity temporal autocorrelation function of diffusely scattered light. However, DCS autocorrelation function measurements in tissue better match theoretical predictions based on the diffusive motion of the scatterers than those based on a model where the advective nature of blood flow dominates the stochastic properties of the scattered light. We have recently shown using Monte Carlo (MC) simulations and assuming a simplistic vascular geometry and laminar flow profile that the diffusive nature of the DCS autocorrelation function decay is likely a result of the shear-induced diffusion of the red blood cells. Here, we provide theoretical derivations supporting and generalizing the previous MC results. Based on the theory of diffusing-wave spectroscopy, we derive an expression for the autocorrelation function along the photon path through a vessel that takes into account both diffusive and advective scatterer motion, and we provide the solution for the DCS autocorrelation function in a semi-infinite geometry. We also derive the correlation diffusion and correlation transfer equation, which can be applied for an arbitrary sample geometry. Further, we propose a method to take into account realistic vascular morphology and flow profile.

  20. Autoregulation of cerebral blood flow in orthostatic hypotension

    Science.gov (United States)

    Novak, V.; Novak, P.; Spies, J. M.; Low, P. A.

    1998-01-01

    BACKGROUND AND PURPOSE: We sought to evaluate cerebral autoregulation in patients with orthostatic hypotension (OH). METHODS: We studied 21 patients (aged 52 to 78 years) with neurogenic OH during 80 degrees head-up tilt. Blood flow velocities (BFV) from the middle cerebral artery were continuously monitored with transcranial Doppler sonography, as were heart rate, blood pressure (BP), cardiac output, stroke volume, CO2, total peripheral resistance, and cerebrovascular resistance. RESULTS: All OH patients had lower BP (PTPR (P.75) but with a flat slope. An expansion of the "autoregulated" range was seen in some patients. The OH_AF group was characterized by a profound fall in BFV in response to a small reduction in BP (mean deltaBP .75). CONCLUSIONS: The most common patterns of cerebral response to OH are autoregulatory failure with a flat flow-pressure relationship or intact autoregulation with an expanded autoregulated range. The least common pattern is autoregulatory failure with a steep flow-pressure relationship. Patients with patterns 1 and 2 have an enhanced capacity to cope with OH, while those with pattern 3 have reduced capacity.

  1. Regional cerebral blood flow and blood volume in patients with subcortical arteriosclerotic encephalopathy (SAE).

    Science.gov (United States)

    Gückel, Friedemann J; Brix, Gunnar; Hennerici, Michael; Lucht, Robert; Ueltzhöffer, Christine; Neff, Wolfgang

    2007-10-01

    The aim of the present study was a detailed analysis of the regional cerebral blood flow and blood volume in patients with subcortical arteriosclerotic encephalopathy (SAE) by means of functional magnetic resonance imaging (MRI). A group of 26 patients with SAE and a group of 16 age-matched healthy volunteers were examined. Using a well-established dynamic susceptibility contrast-enhanced MRI method, the regional cerebral blood flow (rCBF) and blood volume (rCBV) were quantified for each subject in 12 different regions in the brain parenchyma. As compared to healthy volunteers, patients with SAE showed significantly reduced rCBF and rCBV values in white matter regions and in the occipital cortex. Regions containing predominantly grey matter show almost normal rCBF and rCBV values. In conclusion, quantitative analysis of rCBF and rCBV values demonstrates clearly that SAE is a disease that is associated with a reduced microcirculation predominantly in white matter.

  2. Cerebral blood flow autoregulation in experimental liver failure

    DEFF Research Database (Denmark)

    Dethloff, T.J.; Larsen, F.S.; Knudsen, Gitte Moos

    2008-01-01

    Patients with acute liver failure (ALF) display impairment of cerebral blood flow (CBF) autoregulation, which may contribute to the development of fatal intracranial hypertension, but the pathophysiological mechanism remains unclear. In this study, we examined whether loss of liver mass causes...... impairment of CBF autoregulation. Four rat models were chosen, each representing different aspects of ALF: galactosamine (GlN) intoxication represented liver necrosis, 90% hepatectomy (PHx90) represented reduction in liver mass, portacaval anastomosis (PCA) represented shunting of blood....../toxins into the systemic circulation thus mimicking intrahepatic shunting in ALF, PCA+NH(3) provided information about the additional effects of hyperammonemia Rats were intubated and sedated with pentobarbital. We measured CBF with laser Doppler, intracranial pressure (ICP) was measured in the fossa posterior...

  3. Comparison of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) - First real world experience

    NARCIS (Netherlands)

    Haerle, Tobias; Bojara, Waldemar; Meyer, Sven; Elsaesser, Albrecht

    2015-01-01

    Background: The instantaneous wave-free ratio (iFR) is a new adenosine-independent index of coronary stenosis severity. Most published data have been based on off-line analyses of pressure recordings in a core laboratory. We prospectively compared real-time iFR and fractional flow reserve (FFR) meas

  4. Endoscopic retrograde cholangiopancreatography causes reduced myocardial blood flow

    DEFF Research Database (Denmark)

    Christensen, M; Hendel, H W; Rasmussen, V;

    2002-01-01

    ). PATIENTS AND METHODS: 11 patients scheduled for ERCP were monitored with a Holter tape recorder and underwent myocardial perfusion scintigraphies, to evaluate myocardial perfusion at rest and during ERCP. RESULTS: Ten patients completed the study. Eight patients had no sign of myocardial ischemia...... with either of the two methods, while two patients developed signs of ischemia during ERCP with both the Holter tape recording and on myocardial scintigraphy (P = 0.02). CONCLUSIONS: Patients undergoing ERCP may develop true myocardial ischemia with reduced myocardial blood flow. Although this is a small...

  5. Oscillations and chaos in renal blood flow control

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H

    1993-01-01

    In normotensive, halothane-anesthetized rats, oscillations can be found both in the single-nephron blood flow and in the tubular pressure. Experimental data and computer simulations support the hypothesis that the oscillations are caused by the tubuloglomerular feedback (TGF) mechanism. Model...... to the other. In renovascular and spontaneously hypertensive rats, regular oscillations give way to highly irregular, chaotic fluctuations. The chaotic fluctuations appear to have the same mechanism as the regular TGF-mediated oscillations. The irregular fluctuations most likely represent a parameter...

  6. Skin blood flow with elastic compressive extravehicular activity space suit.

    Science.gov (United States)

    Tanaka, Kunihiko; Gotoh, Taro M; Morita, Hironobu; Hargens, Alan R

    2003-10-01

    During extravehicular activity (EVA), current space suits are pressurized with 100% oxygen at approximately 222 mmHg. A tight elastic garment, or mechanical counter pressure (MCP) suit that generates pressure by compression, may have several advantages over current space suit technology. In this study, we investigated local microcirculatory effects produced with negative ambient pressure with an MCP sleeve. The MCP glove and sleeve generated pressures similar to the current space suit. MCP remained constant during negative pressure due to unchanged elasticity of the material. Decreased skin capillary blood flow and temperature during MCP compression was counteracted by greater negative pressure or a smaller pressure differential.

  7. Dynamics of renal blood flow autoregulation in rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Wagner, A J; Marsh, D J

    1991-01-01

    Two separate components could be resolved in tests of the dynamic autoregulation of renal blood flow. The slow component corresponds to the frequency at which spontaneous proximal tubular pressure oscillations are found, and are most likely due to the operation of the TGF. The high frequency...... component most likely represents an intrinsic vascular, myogenic, mechanism. The gain maximum of the admittance in the frequency range corresponding to the autonomous tubular oscillations indicates that the dynamic characteristics responsible for the occurrence of the spontaneous tubular oscillations must...

  8. Usefulness of coronary flow reserve over regional wall motion when added to dual-imaging dipyridamole echocardiography.

    Science.gov (United States)

    Rigo, Fausto; Richieri, Margherita; Pasanisi, Emilio; Cutaia, Valeria; Zanella, Carlo; Della Valentina, Patrizia; Di Pede, Francesco; Raviele, Antonio; Picano, Eugenio

    2003-02-01

    Vasodilator stress echocardiography allows semi-simultaneous imaging of left anterior descending (LAD) coronary flow and regional wall function. To assess the relative (and additive?) value of regional flow and function for noninvasive identification of angiographically assessed LAD disease in patients with chest pain syndrome, we studied 230 consecutive in-hospital patients (134 men, aged 63.5 +/- 11 years) with chest pain syndrome and normal regional and global left ventricular function. All patients underwent stress echocardiography with dipyridamole (up to 0.84 mg/kg over 10 minutes), including wall motion analysis by 2-dimensional echocardiography and coronary flow reserve (CFR) evaluation of the LAD artery by Doppler, with or without contrast injection. A new regional wall motion abnormality in >or=2 contiguous segments was required for 2-dimensional echocardiographic positivity. CFR was evaluated as the ratio of dipyridamole to peak diastolic coronary blood flow velocity at rest. All patients underwent coronary angiography within 60 days; a quantitatively assessed diameter reduction >50% of the LAD artery was considered significant. Of the 230 patients, 70 had LAD disease. A regional wall motion abnormality in LAD territory was present in 52 patients, and reduced CFR (<1.9) in 62 patients. Sensitivity for detecting LAD disease was 74% for 2-dimensional echocardiography (95% confidence interval [CI] 64% to 84%) and 81% for CFR <1.9 (95% CI 72% to 90%); specificity was 91% (95% CI 87% to 96%) for 2-dimensional echocardiography and 84% for CFR (95% CI 79% to 90%). Accuracy was 86% for 2-dimensional echocardiography (95% CI 82% to 91%) and 83.5% for CFR (95% CI 79% to 88%). When 2-dimensional echocardiography and CFR criteria were considered, sensitivity increased to 93% (95% CI 87% to 99%), with 80.6% specificity (95% CI 74.5% to 86.7%). CFR was assessed during vasodilator stress echocardiography. Its diagnostic accuracy for detecting LAD disease was comparable

  9. Measurement of pulmonary flow reserve and pulmonary index of microcirculatory resistance for detection of pulmonary microvascular obstruction.

    Directory of Open Access Journals (Sweden)

    Rahn Ilsar

    Full Text Available BACKGROUND: The pulmonary microcirculation is the chief regulatory site for resistance in the pulmonary circuit. Despite pulmonary microvascular dysfunction being implicated in the pathogenesis of several pulmonary vascular conditions, there are currently no techniques for the specific assessment of pulmonary microvascular integrity in humans. Peak hyperemic flow assessment using thermodilution-derived mean transit-time (T(mn facilitate accurate coronary microcirculatory evaluation, but remain unvalidated in the lung circulation. Using a high primate model, we aimed to explore the use of T(mn as a surrogate of pulmonary blood flow for the purpose of measuring the novel indices Pulmonary Flow Reserve [PFR = (maximum hyperemic/(basal flow] and Pulmonary Index of Microcirculatory Resistance [PIMR = (maximum hyperemic distal pulmonary artery pressurex(maximum hyperemic T(mn]. Ultimately, we aimed to investigate the effect of progressive pulmonary microvascular obstruction on PFR and PIMR. METHODS AND RESULTS: Temperature- and pressure-sensor guidewires (TPSG were placed in segmental pulmonary arteries (SPA of 13 baboons and intravascular temperature measured. T(mn and hemodynamics were recorded at rest and following intra-SPA administration of the vasodilator agents adenosine (10-400 microg/kg/min and papaverine (3-24 mg. Temperature did not vary with intra-SPA sensor position (0.010+/-0.009 v 0.010+/-0.009 degrees C; distal v proximal; p = 0.1, supporting T(mn use in lung for the purpose of hemodynamic indices derivation. Adenosine (to 200 microg/kg/min & papaverine (to 24 mg induced dose-dependent flow augmentations (40+/-7% & 35+/-13% T(mn reductions v baseline, respectively; p<0.0001. PFR and PIMR were then calculated before and after progressive administration of ceramic microspheres into the SPA. Cumulative microsphere doses progressively reduced PFR (1.41+/-0.06, 1.26+/-0.19, 1.17+/-0.07 & 1.01+/-0.03; for 0, 10(4, 10(5 & 10(6 microspheres; p

  10. Developmental validation of a novel lateral flow strip test for rapid identification of human blood (Rapid Stain Identification--Blood).

    Science.gov (United States)

    Schweers, Brett A; Old, Jennifer; Boonlayangoor, P W; Reich, Karl A

    2008-06-01

    Human blood is the body fluid most commonly encountered at crime scenes, and blood detection may aid investigators in reconstructing what occurred during a crime. In addition, blood detection can help determine which items of evidence should be processed for DNA-STR testing. Unfortunately, many common substances can cause red-brown stains that resemble blood. Furthermore, many current human blood detection methods are presumptive and prone to false positive results. Here, the developmental validation of a new blood identification test, Rapid Stain Identification--Blood (RSID--Blood), is described. RSID--Blood utilizes two anti-glycophorin A (red blood cell membrane specific protein) monoclonal antibodies in a lateral flow strip test format to detect human blood. We present evidence demonstrating that this test is accurate, reproducible, easy to use, and highly specific for human blood. Importantly, RSID--Blood does not cross-react with ferret, skunk, or primate blood and exhibits no high-dose hook effect. Also, we describe studies on the sensitivity, body fluid specificity, and species specificity of RSID--Blood. In addition, we show that the test can detect blood from a variety of forensic exhibits prior to processing for DNA-STR analysis. In conclusion, we suggest that RSID--Blood is effective and useful for the detection of human blood on forensic exhibits, and offers improved blood detection when compared to other currently used methods.

  11. In-vitro laser anemometry blood flow systems

    Science.gov (United States)

    Liepsch, Dieter W.; Poll, Axel; Pflugbeil, Gottlieb

    1993-08-01

    Lasers are used in a wide variety of medical applications. While laser catheters have been developed for highly accurate velocity measurements these are invasive; noninvasive techniques are more desirable but not as precise. The laser is, however, a great tool for in vitro measurements. Several groups internationally are using the laser in the study of local velocity distribution in microscopic areas of specially constructed models. Laser Doppler anemometry is widely used to measure the local, time-dependent velocities, while phase Doppler anemometry has been developed to measure particle size, distribution and velocity. Most recently, laser analyzer techniques have been developed for analyzing the particle size of two phase flow systems. It has become increasingly important for physicians to visualize blood flow. In addition to the techniques mentioned above, several laser sheet techniques have been developed for precise measurements. This paper presents a short review of laser techniques and shows some applications especially for the laser-Doppler anemometer.

  12. Holographic laser Doppler imaging of microvascular blood flow

    CERN Document Server

    Magnain, C; Boucneau, T; Simonutti, M; Ferezou, I; Rancillac, A; Vitalis, T; Sahel, J A; Paques, M; Atlan, M

    2014-01-01

    We report on local superficial blood flow monitoring in biological tissue from laser Doppler holographic imaging. In time averaging recording conditions, holography acts as a narrowband bandpass filter, which, combined with a frequency shifted reference beam, permits frequency selective imaging in the radiofrequency range. These Doppler images are acquired with an off axis Mach Zehnder interferometer. Microvascular hemodynamic components mapping is performed in the cerebral cortex of the mouse and the eye fundus of the rat with near-infrared laser light without any exogenous marker. These measures are made from a basic inverse method analysis of local first order optical fluctuation spectra at low radiofrequencies, from 0 Hz to 100 kHz. Local quadratic velocity is derived from Doppler broadenings induced by fluid flows, with elementary diffusing wave spectroscopy formalism in backscattering configuration. We demonstrate quadratic mean velocity assessment in the 0.1 to 10 millimeters per second range in vitro ...

  13. Cerebral blood flow in patients with dementia of Alzheimer's type

    DEFF Research Database (Denmark)

    Postiglione, A; Lassen, N A; Holman, B L

    1993-01-01

    In the normal brain as well as in Alzheimer's disease (AD), regional cerebral blood flow (CBF) is coupled to metabolic demand and, therefore, changes in CBF reflect variations in neuronal metabolism. The use of radionuclide techniques, such as positron emission tomography (PET) and single photon...... of the disease. Lateral CBF asymmetry is also very frequent; speech disorders are highly characteristic of left-sided flow reduction, while visuospatial apraxia is dominating in the right-sided cases. In advanced and severe cases of AD, CBF and metabolism tend to be more uniformly reduced throughout the cortex......, sparing only the primary visual and sensory-motor cortices. PET and SPECT measurement of brain perfusion and metabolism has added a new dimension to the knowledge of dementia disorders, with a better differential diagnosis between AD and other forms of dementia. The correlation with neuropsychological...

  14. Validation of Blood Flow Simulations in Intracranial Aneurysms

    Science.gov (United States)

    Yu, Yue; Anor, Tomer; Baek, Hyoungsu; Jayaraman, Mahesh; Madsen, Joseph; Karniadakis, George

    2010-11-01

    Catheter-based digital subtraction angiography (DSA) is the most accurate diagnostic procedure for investigating vascular anomalies and cerebral blood flow. Here we describe utilization of DSA in a patient with an intracranial aneursysm to validate corresponding spectral element simulations. Subsequently, we examine via visualization the structure of flow in internal carotid arteries laden with three different types of aneurysms: (1) a wide-necked saccular aneurysm, (2) a narrower-necked saccular aneurysm, and (3) a case with two adjacent saccular aneurysms. We have found through high resolution simulations that in cases (1) and (3) in physiological conditions a hydrodynamic instability occurs during the decelerating systolic phase resulting in a high frequency oscillation (20-50 Hz). We use the in-silico dye visualization to discriminate among different physical mechanisms causing the instability and contrast their effect with case (2) for which an instability arises only at much higher flowrates.

  15. Reduced coronary flow reserve in patients with primary hyperparathyroidism: a study by G-SPECT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Cecilia [CNR Institute of Bioimages and Molecular Physiology Milan, Genoa (Italy); Giusti, Massimo; Vera, Lara; Minuto, Francesco [University of Genoa, Department of Endocrinological and Metabolic Sciences, Genoa (Italy); Armonino, Riccardo; Ghigliotti, Giorgio; Bezante, Gian Paolo; Morbelli, Silvia; Pomposelli, Elena; Massollo, Michela; Gandolfo, Patrizia; Sambuceti, Gianmario [University of Genoa, Department of Internal Medicine, Genoa (Italy)

    2010-12-15

    The mechanisms underlying increased cardiovascular risk in primary hyperparathyroidism (pHPT) have not been fully defined. Recently, this issue has become the subject of renewed interest due to the increasing evidence that the endothelium and vascular wall are targets for parathyroid hormone (PTH). The aim of this study was to measure regional coronary flow reserve (CFR) to determine whether the vascular damage induced by pHPT extends to affect the coronary microvascular function. A total of 22 pHPT patients without a history of coronary artery disease and 7 age-matched control subjects were recruited. Dipyridamole myocardial blood flow (MBF) was assessed using {sup 99m}Tc-sestamibi by measuring first-transit counts in the pulmonary artery and myocardial count rate from G-SPECT images. Baseline MBF was estimated 2 h later according to the same procedure. Regional CFR was defined as the ratio between dipyridamole and baseline MBF using a 17-segment left ventricular model. Three pHPT patients showed reversible perfusion defects and were excluded from the analysis. In the remaining 19, CFR was significantly lower with respect to the control subjects (1.88 {+-} 0.64 vs. 3.36 {+-} 0.66, respectively; p < 0.01). Moreover, patients studied for more than 28 months from pHPT diagnosis showed lower CFR values than the others (1.42 {+-} 0.18 vs. 2.25 {+-} 0.64, respectively; p < 0.01). Consequently, the time from diagnosis to the nuclear study showed a reasonable correlation with the degree of CFR impairment (Spearman's rho -0.667, p < 0.02). pHPT is associated with a significant dysfunction of the coronary microcirculation. This disorder might contribute to the high cardiovascular risk of conditions characterized by chronic elevations in serum PTH levels. (orig.)

  16. Assessment of renal artery stenosis using both resting pressures ratio and fractional flow reserve: relationship to angiography and ultrasonography.

    Science.gov (United States)

    Kadziela, Jacek; Witkowski, Adam; Januszewicz, Andrzej; Cedro, Krzysztof; Michałowska, Ilona; Januszewicz, Magdalena; Kabat, Marek; Prejbisz, Aleksander; Kalińczuk, Lukasz; Zieleń, Piotr; Michel-Rowicka, Katarzyna; Warchoł, Ewa; Rużyłło, Witold

    2011-08-01

    BACKGROUND. Clinical benefit from renal artery revascularization remains controversial, probably because of inaccurate stenosis severity assessment. Objective. The aim of the study was to evaluate resting translesional pressures ratio and renal fractional flow reserve (rFFR) in relation to angiography and Doppler duplex ultrasonography in patients with at least moderate renal artery stenosis (RAS). METHODS. 44 hypertensive patients (48% of males, mean age 65 years) with at least moderate RAS were investigated. Translesional systolic pressure gradient (TSPG), resting Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were evaluated. Quantitative angiographic analysis of stenosis severity was performed including minimal lumen diameter (MLD) and percent diameter stenosis (DS) assessment. Renal/aortic ratio (RAR), resistive index (RI) and deltaRI (side-to side difference) were obtained in Doppler-duplex ultrasonography. The predictive value of selected variables was calculated using receiver-operating characteristics curves. RESULTS. Mean Pd/Pa ratio was 0.86 ± 0.12 and decreased to 0.79 ± 0.13 after papaverine administration. Both Pd/Pa ratio and rFFR strongly correlated with TSPG (r = -0.92, p ratio and 0.80 for rFFR. CONCLUSIONS. Mean Pd/Pa ratio and rFFR strongly correlated with angiographic data and in less pronounced manner with ultrasound parameters reflecting intrarenal blood flow. The best accuracy cut-off points for severe RAS predicting were 0.93 and 0.80, respectively.

  17. Numerical Simulation of Unsteady Blood Flow through Capillary Networks.

    Science.gov (United States)

    Davis, J M; Pozrikidis, C

    2011-08-01

    A numerical method is implemented for computing unsteady blood flow through a branching capillary network. The evolution of the discharge hematocrit along each capillary segment is computed by integrating in time a one-dimensional convection equation using a finite-difference method. The convection velocity is determined by the local and instantaneous effective capillary blood viscosity, while the tube to discharge hematocrit ratio is deduced from available correlations. Boundary conditions for the discharge hematocrit at divergent bifurcations arise from the partitioning law proposed by Klitzman and Johnson involving a dimensionless exponent, q≥1. When q=1, the cells are partitioned in proportion to the flow rate; as q tends to infinity, the cells are channeled into the branch with the highest flow rate. Simulations are performed for a tree-like, perfectly symmetric or randomly perturbed capillary network with m generations. When the tree involves more than a few generations, a supercritical Hopf bifurcation occurs at a critical value of q, yielding spontaneous self-sustained oscillations in the absence of external forcing. A phase diagram in the m-q plane is presented to establish conditions for unsteady flow, and the effect of various geometrical and physical parameters is examined. For a given network tree order, m, oscillations can be induced for a sufficiently high value of q by increasing the apparent intrinsic viscosity, decreasing the ratio of the vessel diameter from one generation to the next, or by decreasing the diameter of the terminal vessels. With other parameters fixed, oscillations are inhibited by increasing m. The results of the continuum model are in excellent agreement with the predictions of a discrete model where the motion of individual cells is followed from inlet to outlet.

  18. Human red blood cells deformed under thermal fluid flow.

    Science.gov (United States)

    Foo, Ji-Jinn; Chan, Vincent; Feng, Zhi-Qin; Liu, Kuo-Kang

    2006-03-01

    The flow-induced mechanical deformation of a human red blood cell (RBC) during thermal transition between room temperature and 42.0 degrees C is interrogated by laser tweezer experiments. Based on the experimental geometry of the deformed RBC, the surface stresses are determined with the aid of computational fluid dynamics simulation. It is found that the RBC is more deformable while heating through 37.0 degrees C to 42.0 degrees C, especially at a higher flow velocity due to a thermal-fluid effect. More importantly, the degree of RBC deformation is irreversible and becomes softer, and finally reaches a plateau (at a uniform flow velocity U > 60 microm s(-1)) after the heat treatment, which is similar to a strain-hardening dominated process. In addition, computational simulated stress is found to be dependent on the progression of thermotropic phase transition. Overall, the current study provides new insights into the highly coupled temperature and hydrodynamic effects on the biomechanical properties of human erythrocyte in a model hydrodynamic flow system.

  19. Measurement of anterior and posterior circulation flow contributions to cerebral blood flow. An ultrasound-derived volumetric flow analysis.

    Science.gov (United States)

    Boyajian, R A; Schwend, R B; Wolfe, M M; Bickerton, R E; Otis, S M

    1995-01-01

    Ultrasound-derived volumetric flow analysis may be useful in answering questions of basic physiological interest in the cerebrovascular circulation. Using this technique, the authors have sought to describe quantitatively the complete concurrent flow relations among all four arteries supplying the brain. The aim of this study of normal subjects was to determine the relative flow contributions of the anterior (internal carotid arteries) and posterior (vertebral arteries) cerebral circulation. Comparisons between the observed and theoretically expected anterior and posterior flow distribution would provide an opportunity to assess traditional rheological conceptions in vivo. Pulsed color Doppler ultrasonography was used to measure mean flow rates in the internal carotid and vertebral arteries in 21 normal adults. The anterior circulation (internal carotid arteries bilaterally) carried 82% of the brain's blood supply and comprised 67% of the total vascular cross-sectional area. These values demonstrate precise concordance between observations in vivo and the theoretically derived (Hagen-Poiseuille) expected flow distribution. These cerebrovascular findings support the traditional conception of macroscopic blood flow. Further studies using ultrasound-derived volumetric analysis of the brain's arterial flow relations may illuminate the vascular pathophysiology underlying aging, cerebral ischemia, and dementias.

  20. Angiographic coronary stenosis versus (15)O-water PET myocardial blood flow

    DEFF Research Database (Denmark)

    Thomassen, Anders; Braad, Poul-Erik; Johansen, Allan;

    2013-01-01

    Purpose: To examine which of stress myocardial flow (MBF) and coronary flow reserve (CFR) determined by (15)-water-PET (PET) correspond most closely with diameter stenosis assessed by quantitative coronary angiography (QCA). Methods: Twenty-three patients with a C40% QCA stenosis underwent baseline...

  1. A reconstruction method of intra-ventricular blood flow using color flow ultrasound: a simulation study

    Science.gov (United States)

    Jang, Jaeseong; Ahn, Chi Young; Jeon, Kiwan; Choi, Jung-il; Lee, Changhoon; Seo, Jin Keun

    2015-03-01

    A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color Doppler echocardiography measurement. From 3D incompressible Navier- Stokes equation, a 2D incompressible Navier-Stokes equation with a mass source term is derived to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. For demonstrating a feasibility of the proposed method, we have performed numerical simulations of the forward problem and numerical analysis of the reconstruction method. First, we construct a 3D moving LV region having a specific stroke volume. To obtain synthetic intra-ventricular flows, we performed a numerical simulation of the forward problem of Navier-Stokes equation inside the 3D moving LV, computed 3D intra-ventricular velocity fields as a solution of the forward problem, projected the 3D velocity fields on the imaging plane and took the inner product of the 2D velocity fields on the imaging plane and scanline directional velocity fields for synthetic scanline directional projected velocity at each position. The proposed method utilized the 2D synthetic projected velocity data for reconstructing LV blood flow. By computing the difference between synthetic flow and reconstructed flow fields, we obtained the averaged point-wise errors of 0.06 m/s and 0.02 m/s for u- and v-components, respectively.

  2. Alterations of Regional Cerebral Blood Flow in Major Depressive Disorder

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Hyoung; Chung, Yong An; Seo, Ye Young; Yoo, Ik Dong; Na, Sae Jung; Jung, Hyun Suk; Kim, Ki Jun [College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2009-04-15

    The authors analyzed how the regional cerebral blood flow (rCBF) findings of patients with major depression differ from the normal control, and our results were compared to previous reports. Twelve patients fulfilling DSM-IV criteria for major depression who were off all psychotropic medications for > 4 weeks (male: 7, female: 5, age range: 19approx52 years, average age: 29.3+-9.9 years) and 14 normal volunteers (male: 8, female: 6, age range: 19approx53 years, average age: 31.4+-9.2 years) were recruited. Images of brain perfusion SPECT were obtained using Tc-99m ECD and patterns of the rCBF were compared between patients with major depression and the healthy control subjects. The patients with major depression showed increase of the r-CBF in right lingual gyrus, right fusiform gyrus, left lingual gyrus, left precuneus, and left superior temporal gyrus, and showed decrease of r-CBF in right pons, left medial frontal gyrus, cingulate gyrus of left limbic lobe, cingulate gyrus of right frontal lobe, and cingulate gyrus of right limbic lobe compared to the normal control. The Tc-99m ECD brain perfusion SPECT findings in our study did not differ from the previously reported regional cerebral blood flow pattern of patients with major depression. Especially, decreased rCBF pattern typical to major depression patients in the right pons, left medial frontal gyrus, and cingulate regions was clearly demonstrated

  3. Monitoring blood flow and photobleaching during topical ALA PDT treatment

    Science.gov (United States)

    Sands, Theresa L.; Sunar, Ulas; Foster, Thomas H.; Oseroff, Allan R.

    2009-02-01

    Photodynamic therapy (PDT) using topical aminolevulinic acid (ALA) is currently used as a clinical treatment for nonmelanoma skin cancers. In order to optimize PDT treatment, vascular shutdown early in treatment must be identified and prevented. This is especially important for topical ALA PDT where vascular shutdown is only temporary and is not a primary method of cell death. Shutdown in vasculature would limit the delivery of oxygen which is necessary for effective PDT treatment. Diffuse correlation spectroscopy (DCS) was used to monitor relative blood flow changes in Balb/C mice undergoing PDT at fluence rates of 10mW/cm2 and 75mW/cm2 for colon-26 tumors implanted intradermally. DCS is a preferable method to monitor the blood flow during PDT of lesions due to its ability to be used noninvasively throughout treatment, returning data from differing depths of tissue. Photobleaching of the photosensitizer was also monitored during treatment as an indirect manner of monitoring singlet oxygen production. In this paper, we show the conditions that cause vascular shutdown in our tumor model and its effects on the photobleaching rate.

  4. Multiscale modeling and simulation of brain blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Perdikaris, Paris, E-mail: parisp@mit.edu [Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Grinberg, Leopold, E-mail: leopoldgrinberg@us.ibm.com [IBM T.J Watson Research Center, 1 Rogers St, Cambridge, Massachusetts 02142 (United States); Karniadakis, George Em, E-mail: george-karniadakis@brown.edu [Division of Applied Mathematics, Brown University, Providence, Rhode Island 02912 (United States)

    2016-02-15

    The aim of this work is to present an overview of recent advances in multi-scale modeling of brain blood flow. In particular, we present some approaches that enable the in silico study of multi-scale and multi-physics phenomena in the cerebral vasculature. We discuss the formulation of continuum and atomistic modeling approaches, present a consistent framework for their concurrent coupling, and list some of the challenges that one needs to overcome in achieving a seamless and scalable integration of heterogeneous numerical solvers. The effectiveness of the proposed framework is demonstrated in a realistic case involving modeling the thrombus formation process taking place on the wall of a patient-specific cerebral aneurysm. This highlights the ability of multi-scale algorithms to resolve important biophysical processes that span several spatial and temporal scales, potentially yielding new insight into the key aspects of brain blood flow in health and disease. Finally, we discuss open questions in multi-scale modeling and emerging topics of future research.

  5. Clustering of microscopic particles in constricted blood flow

    CERN Document Server

    Bächer, Christian; Gekle, Stephan

    2016-01-01

    A mixed suspension of red blood cells (RBCs) and microparticles flows through a cylindrical channel with a constriction mimicking a stenosed blood vessel. Our three-dimensional Lattice-Boltzmann simulations show that the RBCs are depleted right ahead and after the constriction. Although the RBC mean concentration (hematocrit) is 16.5% or 23.7%, their axial concentration profile is very similar to that of isolated tracer particles flowing along the central axis. Most importantly, however, we find that the stiff microparticles exhibit the opposite behavior. Arriving on a marginated position near the channel wall, they can pass through the constriction only if they find a suitable gap to dip into the dense plug of RBCs occupying the channel center. This leads to a prolonged dwell time and, as a consequence, to a pronounced increase in microparticle concentration right in front of the constriction. For biochemically active particles such as drug delivery agents or activated platelets this clustering may lead to p...

  6. Clustering of microscopic particles in constricted blood flow

    Science.gov (United States)

    Bächer, Christian; Schrack, Lukas; Gekle, Stephan

    2017-01-01

    A mixed suspension of red blood cells (RBCs) and microparticles flows through a cylindrical channel with a constriction mimicking a stenosed blood vessel. Our three-dimensional Lattice-Boltzmann simulations show that the RBCs are depleted right ahead of and after the constriction. Although the RBC mean concentration (hematocrit) is 16.5% or 23.7%, their axial concentration profile is very similar to that of isolated tracer particles flowing along the central axis. Most importantly, however, we find that the stiff microparticles exhibit the opposite behavior. Arriving on a marginated position near the channel wall, they can pass through the constriction only if they find a suitable gap to dip into the dense plug of RBCs occupying the channel center. This leads to a prolonged dwell time and, as a consequence, to a pronounced increase in microparticle concentration right in front of the constriction. For biochemically active particles such as drug delivery agents or activated platelets this clustering may have important physiological consequences, e.g., for the formation of microthrombi.

  7. Adipose tissue and skeletal muscle blood flow during mental stress

    Energy Technology Data Exchange (ETDEWEB)

    Linde, B.; Hjemdahl, P.; Freyschuss, U.; Juhlin-Dannfelt, A.

    1989-01-01

    Mental stress (a modified Stroop color word conflict test (CWT)) increased adipose tissue blood flow (ATBF; 133Xe clearance) by 70% and reduced adipose tissue vascular resistance (ATR) by 25% in healthy male volunteers. The vasculatures of adipose tissue (abdomen as well as thigh), skeletal muscle of the calf (133Xe clearance), and the entire calf (venous occlusion plethysmography) responded similarly. Arterial epinephrine (Epi) and glycerol levels were approximately doubled by stress. Beta-Blockade by metoprolol (beta 1-selective) or propranolol (nonselective) attenuated CWT-induced tachycardia similarly. Metoprolol attenuated stress-induced vasodilation in the calf and tended to do so in adipose tissue. Propranolol abolished vasodilation in the calf and resulted in vasoconstriction during CWT in adipose tissue. Decreases in ATR, but not in skeletal muscle or calf vascular resistances, were correlated to increases in arterial plasma glycerol (r = -0.42, P less than 0.05), whereas decreases in skeletal muscle and calf vascular resistances, but not in ATR, were correlated to increases in arterial Epi levels (r = -0.69, P less than 0.01; and r = -0.43, P less than 0.05, respectively). The results suggest that mental stress increases nutritive blood flow in adipose tissue and skeletal muscle considerably, both through the elevation of perfusion pressure and via vasodilatation. Withdrawal of vasoconstrictor nerve activity, vascular beta 2-adrenoceptor stimulation by circulating Epi, and metabolic mechanisms (in adipose tissue) may contribute to the vasodilatation.

  8. Local blood flow measured by fluorescence excitation of nonradioactive microspheres

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Y.; Payne, B.D.; Aldea, G.S.; McWatters, C.; Husseini, W.; Mori, H.; Hoffman, J.I.; Kaufman, L. (Univ. of California, San Francisco (USA))

    1990-05-01

    An X-ray fluorescence system with low Compton background and high counting efficiency was developed to measure regional blood flow with nonradioactive microspheres. The performance of the system was tested in vitro by counting mixed aqueous solutions of either Mo, Ag, and I; Nb, Ag, and Ba; or Zr, Mo, Rh, Ag, Sn, I, and Ba, as well as a mixture of Ag and Ba nonradioactive microspheres. Mixtures containing 2-20 ppm of each element were counted for 10 min by the fluorescence system, and the individual elements in mixtures of three to seven nonradioactive elements were measured with high accuracy. The best counting statistics were obtained for Ag. For 10-min counts, the system measures as few as 120 Ag microspheres with 30% standard deviation but measures 800 Ag microspheres per sample with 3.6% standard deviation. We compared regional myocardial blood flows determined simultaneously by fluorescence and radioactive microsphere methods; the latter samples were counted by a 3-in. NaI (Tl) well detector and pulse-height analyzer. The radioactive and nonradioactive measurements showed good correlations.

  9. Fractional flow reserve: physiological basis, advantages and limitations, and potential gender differences.

    Science.gov (United States)

    Crystal, George J; Klein, Lloyd W

    2015-01-01

    Fractional flow reserve (FFR) is a physiological index of the severity of a stenosis in an epicardial coronary artery, based on the pressure differential across the stenosis. Clinicians are increasingly relying on this method because it is independent of baseline flow, relatively simple, and cost effective. The accurate measurement of FFR is predicated on maximal hyperemia being achieved by pharmacological dilation of the downstream resistance vessels (arterioles). When the stenosis causes FFR to be impaired by > 20%, it is considered to be significant and to justify revascularization. A diminished hyperemic response due to microvascular dysfunction can lead to a false normal FFR value, and a misguided clinical decision. The blunted vasodilation could be the result of defects in the signaling pathways modulated (activated or inhibited) by the drug. This might involve a downregulation or reduced number of vascular receptors, endothelial impairment, or an increased activity of an opposing vasoconstricting mechanism, such as the coronary sympathetic nerves or endothelin. There are data to suggest that microvascular dysfunction is more prevalent in post-menopausal women, perhaps due to reduced estrogen levels. The current review discusses the historical background and physiological basis for FFR, its advantages and limitations, and the phenomenon of microvascular dysfunction and its impact on FFR measurements. The question of whether it is warranted to apply gender-specific guidelines in interpreting FFR measurements is addressed.

  10. Comparative Study between Perfusion Changes and Positive Findings on Coronary Flow Reserve

    Science.gov (United States)

    Costantini, Costantino Roberto Frack; Ramires, Jose Antonio; Costantini, Costantino Ortiz; Denk, Marcos Antonio; Tarbine, Sergio Gustavo; Santos, Marcelo de Freitas; Zanuttini, Daniel Aníbal; Silveira, Carmen Weigert; de Souza, Admar Moraes; de Macedo, Rafael Michel

    2017-01-01

    Background Functional assessment of coronary artery obstruction is used in cardiology practice to correlate anatomic obstructions with flow decrease. Among such assessments, the study of the coronary fractional flow reserve (FFR) has become the most widely used. Objective To evaluate the correlation between FFR and findings of ischemia obtained by noninvasive methods including stress echocardiography and nuclear medicine and the presence of critical coronary artery obstruction. Methods Retrospective study of cases treated with systematized and standardized procedures for coronary disease between March 2011 and August 2014. We included 96 patients with 107 critical coronary obstructions (> 50% in the coronary trunk and/or ≥ 70% in other segments) estimated by quantitative coronary angiography (QCA) and intracoronary ultrasound (ICUS). All cases presented ischemia in one of the noninvasive studies. Results All 96 patients presented ischemia (100%) in one of the functional tests. On FFR study with adenosine 140 g/kg/min, 52% of the cases had values ≤ 0.80. On correlation analysis for FFR ≤ 0.80, the evaluation of sensitivity, specificity, positive and negative predictive values, accuracy, and ROC curve in relation to the stenosis degree and length, and presence of ischemia, no significant values or strong correlation were observed. Conclusion Coronary FFR using a cut-off value of 0.80 showed no correlation with noninvasive ischemia tests in patients with severe coronary artery obstructions on QCA and ICUS. PMID:27982159

  11. Comparative Study between Perfusion Changes and Positive Findings on Coronary Flow Reserve

    Directory of Open Access Journals (Sweden)

    Costantino Roberto Frack Costantini

    Full Text Available Abstract Background: Functional assessment of coronary artery obstruction is used in cardiology practice to correlate anatomic obstructions with flow decrease. Among such assessments, the study of the coronary fractional flow reserve (FFR has become the most widely used. Objective: To evaluate the correlation between FFR and findings of ischemia obtained by noninvasive methods including stress echocardiography and nuclear medicine and the presence of critical coronary artery obstruction. Methods: Retrospective study of cases treated with systematized and standardized procedures for coronary disease between March 2011 and August 2014. We included 96 patients with 107 critical coronary obstructions (> 50% in the coronary trunk and/or ≥ 70% in other segments estimated by quantitative coronary angiography (QCA and intracoronary ultrasound (ICUS. All cases presented ischemia in one of the noninvasive studies. Results: All 96 patients presented ischemia (100% in one of the functional tests. On FFR study with adenosine 140 g/kg/min, 52% of the cases had values ≤ 0.80. On correlation analysis for FFR ≤ 0.80, the evaluation of sensitivity, specificity, positive and negative predictive values, accuracy, and ROC curve in relation to the stenosis degree and length, and presence of ischemia, no significant values or strong correlation were observed. Conclusion: Coronary FFR using a cut-off value of 0.80 showed no correlation with noninvasive ischemia tests in patients with severe coronary artery obstructions on QCA and ICUS.

  12. Coronary Flow Reserve Predicts Cardiopulmonary Fitness in Patients with Coronary Artery Disease Independently of Systolic and Diastolic Function

    DEFF Research Database (Denmark)

    Snoer, Martin; Olsen, Rasmus Huan; Monk-Hansen, Tea

    2014-01-01

    Aims Despite revascularization and optimal medical treatment, patients with coronary artery disease (CAD) have reduced exercise capacity. In the absence of coronary artery stenosis, coronary flow reserve (CFR) is a measure of coronary microvascular function, and a marker of future poor outcome...... early (E) and late (A) inflow velocities, and tissue Doppler diastolic (e′) and systolic (s′) velocities. Peak coronary flow velocity (CFV) was measured in the LAD using pulse-wave Doppler. CFR was calculated as the ratio between peak CFV at rest and during vasodilator stress. Median CFR was 2.22 (1....... Conclusions Coronary flow reserve measured noninvasively predicts cardiopulmonary fitness independently of resting systolic and diastolic function in CAD patients, indicating that cardiac output during maximal exercise is dependent on the ability of the coronary circulation to adapt to the higher metabolic...

  13. Blood flows and metabolic components of the cardiome.

    Science.gov (United States)

    Bassingthwaighte, J B; Li, Z; Qian, H

    1998-01-01

    This is a plan for the first stage of The Cardiome Project. The cardiome is the representation, in quantitative, testable form, of the functioning of the normal heart and its responses to intervention. The goal is to integrate the efforts of many years into a comprehensive understandable scheme. Past efforts have spanned the fields of transport within blood vessels, the distributions of regional coronary blood flows, permeation processes through capillary and cell walls, mediated cell membrane transport, extra- and intracellular diffusion, cardiac electrophysiology, the uptake and metabolism of the prime substrates (fatty acid and glucose), the metabolism of the purine nucleosides and nucleotides (mainly adenosine and ATP), the regulation of the ionic currents and of excitation-contraction coupling and finally the regulation of contraction. The central theme is to define the coronary flows and metabolic components of a computer model that will become a part of a three-dimensional heart with appropriate fibre shortening and volume ejection. The components are: (a) coronary flow distributions with appropriate heterogeneity, (b) metabolism of the substrates for energy production, (c) ATP, PCr and energy metabolism and (d) calcium metabolism as it relates to excitation-contraction coupling. The modeling should provide: (1) appropriate responses to regional ischemia induced by constriction of a coronary artery, including tissue contractility loss and aneurysmal dilation of the ischemic region; (2) physiological responses to rate changes such as treppe and changes in metabolic demand and (3) changes in local metabolic needs secondary to changes in the site of pacing stimulation and shortening inactivation or stretch activation of contraction.

  14. A simple model of cerebral blood flow dependence on arterial blood pressure

    CERN Document Server

    Gersten, Alexander

    2011-01-01

    It is shown that the dependence of the cerebral blood flow (CBF) on mean arterial blood pressure (MABP) can be described with a simple model having the following assumptions. Below certain MABP (denoted as MABP1) there are no autoregulatory or feedback mechanisms influencing CBF. Between MABP1 and MABP2 (MABP at which breakthrough accurs) there is a linear (on MABP) dependent feedback with a sloap depending very much on the individual considered. The classical autoregulation model with a plateau in between MABP1 and MABP2 is a particular case of this model. The model describes well the experiments performed on dogs (Harper 1966), for which the individual feedback sloap parameter varied to great extent, indicating the importance of mesurments on individuals against averaged mesurments (or measurments on diffent individuals) which superficially support the classical autoregulation. New effect of decreased CBF, while increasing MABP, was observed.

  15. Effect of labetalol on cerebral blood flow and middle cerebral arterial flow velocity in healthy volunteers

    DEFF Research Database (Denmark)

    Schroeder, T; Schierbeck, Jens; Howardy, P;

    1991-01-01

    in normotensive subjects. Neither does it affect CO2 reactivity. The uniform results obtained with the two methods suggest TCD as a usable alternative to conventional CBF technique in the assessment of cerebral vasoactivity of various drugs in subjects with a normal cerebral circulation.......The effect of labetalol, a combined alpha- and beta-adrenoceptor antagonist, on the cerebral circulation was investigated in 7 normotensive subjects. Cerebral blood flow (CBF) was measured with the intravenous 133Xe method and mean flow velocity (Vmean) in the middle cerebral artery was determined...

  16. Absolute counting of neutrophils in whole blood using flow cytometry.

    Science.gov (United States)

    Brunck, Marion E G; Andersen, Stacey B; Timmins, Nicholas E; Osborne, Geoffrey W; Nielsen, Lars K

    2014-12-01

    Absolute neutrophil count (ANC) is used clinically to monitor physiological dysfunctions such as myelosuppression or infection. In the research laboratory, ANC is a valuable measure to monitor the evolution of a wide range of disease states in disease models. Flow cytometry (FCM) is a fast, widely used approach to confidently identify thousands of cells within minutes. FCM can be optimised for absolute counting using spiked-in beads or by measuring the sample volume analysed. Here we combine the 1A8 antibody, specific for the mouse granulocyte protein Ly6G, with flow cytometric counting in straightforward FCM assays for mouse ANC, easily implementable in the research laboratory. Volumetric and Trucount™ bead assays were optimized for mouse neutrophils, and ANC values obtained with these protocols were compared to ANC measured by a dual-platform assay using the Orphee Mythic 18 veterinary haematology analyser. The single platform assays were more precise with decreased intra-assay variability compared with ANC obtained using the dual protocol. Defining ANC based on Ly6G expression produces a 15% higher estimate than the dual protocol. Allowing for this difference in ANC definition, the flow cytometry counting assays using Ly6G can be used reliably in the research laboratory to quantify mouse ANC from a small volume of blood. We demonstrate the utility of the volumetric protocol in a time-course study of chemotherapy induced neutropenia using four drug regimens.

  17. An approach to automatic blood vessel image registration of microcirculation for blood flow analysis on nude mice.

    Science.gov (United States)

    Lin, Wen-Chen; Wu, Chih-Chieh; Zhang, Geoffrey; Wu, Tung-Hsin; Lin, Yang-Hsien; Huang, Tzung-Chi; Liu, Ren-Shyan; Lin, Kang-Ping

    2011-04-01

    Image registration is often a required and a time-consuming step in blood flow analysis of large microscopic video sequences in vivo. In order to obtain stable images for blood flow analysis, frame-to-frame image matching as a preprocessing step is a solution to the problem of movement during image acquisition. In this paper, microscopic system analysis without fluorescent labelling is performed to provide precise and continuous quantitative data of blood flow rate in individual microvessels of nude mice. The performance properties of several matching metrics are evaluated through simulated image registrations. An automatic image registration programme based on Powell's optimisation search method with low calculation redundancy was implemented. The matching method by variance of ratio is computationally efficient and improves the registration robustness and accuracy in practical application of microcirculation registration. The presented registration method shows acceptable results in close requisition to analyse red blood cell velocities, confirming the scientific potential of the system in blood flow analysis.

  18. Upper limit of cerebral blood flow autoregulation in experimental renovascular hypertension in the baboon

    DEFF Research Database (Denmark)

    Strandgaard, S; Jones, J V; MacKenzie, E T;

    1975-01-01

    The effect of arterial hypertension on cerebral blood flow was studied by the intracarotid 133Xe clearance method in baboons. The arterial blood pressure was raised in gradual steps with angiotensin. Baboons with renal hypertension of 8-12 weeks duration were studied along with normotensive baboons....... In initially normotensive baboons, cerebral blood flow remained constant until the mean arterial blood pressure had risen to the range of 140 to 154 mm Hg; thereafter cerebral blood flow increased with each rise in mean arterial blood pressure. In the chronically hypertensive baboons, cerebral blood flow...... remained constant until the mean arterial blood pressure had been elevated to the range of 155 to 169 mm Hg. Thus, in chronic hypertension it appears that there are adaptive changes in the cerebral circulation which may help to protect the brain from further increases in arterial blood pressure....

  19. Theory to predict shear stress on cells in turbulent blood flow.

    Science.gov (United States)

    Morshed, Khandakar Niaz; Bark, David; Forleo, Marcio; Dasi, Lakshmi Prasad

    2014-01-01

    Shear stress on blood cells and platelets transported in a turbulent flow dictates the fate and biological activity of these cells. We present a theoretical link between energy dissipation in turbulent flows to the shear stress that cells experience and show that for the case of physiological turbulent blood flow: (a) the Newtonian assumption is valid, (b) turbulent eddies are universal for the most complex of blood flow problems, and (c) shear stress distribution on turbulent blood flows is possibly universal. Further we resolve a long standing inconsistency in hemolysis between laminar and turbulent flow using the theoretical framework. This work demonstrates that energy dissipation as opposed to bulk shear stress in laminar or turbulent blood flow dictates local mechanical environment of blood cells and platelets universally.

  20. Dynamic Modeling of Renal Blood Flow in Dahl Hypertensive and Normotensive Rats

    DEFF Research Database (Denmark)

    Knudsen, Torben; Elmer, H.; Knudsen, Morten;

    2004-01-01

    A method is proposed in this paper which allows characterisation of renal autoregulatory dynamics and efficiency using quantitative mathematical methods. Based on data from rat experiments, where arterial blood pressure and renal blood flow are measured, a quantitative model for renal blood flow ...

  1. Sympathetic reflex control of subcutaneous blood flow in tetraplegic man during postural changes

    DEFF Research Database (Denmark)

    Skagen, K; Jensen, K; Henriksen, O

    1982-01-01

    1. The effect of head-up tilt upon subcutaneous blood flow in the distal arm and leg was studied in 12 patients with complete traumatic spinal cord transection at the cervical level. 2. Blood flow was measured by the local 133Xe washout technique. 3. Leg lowering induced a 47% decrease in blood f...

  2. Outcome of splanchnic blood flow determination in patients with suspected chronic intestinal ischaemia. A retrospective survey

    DEFF Research Database (Denmark)

    Møller, Søren; Madsen, Jan Lysgård

    2002-01-01

    flow: A, normal response (splanchnic blood flow > or = 200 ml/min); B, possible abnormal response (splanchnic blood flow 51-199 ml/min); and C, definitive abnormal response (splanchnic blood flow place, the type of operation was noted. RESULTS: Forty patients had...... a normal meal-induced response, 23 patients had a possible abnormal response and 10 patients had a definitive abnormal response, which gave evidence of chronic intestinal ischaemia. In the total patient population, the increase in splanchnic blood flow was significantly correlated to an increase in hepatic...

  3. Glucagon-like peptide-2 increases mesenteric blood flow in humans

    DEFF Research Database (Denmark)

    Bremholm, Lasse; Hornum, Mads; Henriksen, Birthe Merete;

    2008-01-01

    OBJECTIVE: Mesenteric blood flow is believed to be influenced by digestion and absorption of ingested macronutrients. We hypothesized that the intestinotrophic hormone, GLP-2 (glucagons-like peptide 2), may be involved in the regulation of mesenteric blood flow. Changes in mesenteric blood flow...... were measured by Doppler ultrasound scanning of the superior mesenteric artery (SMA). The aim of the study was to demonstrate the influence of GLP-2 on this flow, expressed as changes in resistance index (RI). MATERIAL AND METHODS: A homogeneous group of 10 fasting healthy volunteers completed a 2-day...... support the hypothesis that GLP-2 is an important regulator of mesenteric blood flow....

  4. Middle cerebral artery blood velocity and cerebral blood flow and O2 uptake during dynamic exercise

    DEFF Research Database (Denmark)

    Madsen, P L; Sperling, B K; Warming, T

    1993-01-01

    Results obtained by the 133Xe clearance method with external detectors and by transcranial Doppler sonography (TCD) suggest that dynamic exercise causes an increase of global average cerebral blood flow (CBF). These data are contradicted by earlier data obtained during less-well-defined conditions....... To investigate this controversy, we applied the Kety-Schmidt technique to measure the global average levels of CBF and cerebral metabolic rate of oxygen (CMRO2) during rest and dynamic exercise. Simultaneously with the determination of CBF and CMRO2, we used TCD to determine mean maximal flow velocity...... in the middle cerebral artery (MCA Vmean). For values of CBF and MCA Vmean a correction for an observed small drop in arterial PCO2 was carried out. Baseline values for global CBF and CMRO2 were 50.7 and 3.63 ml.100 g-1.min-1, respectively. The same values were found during dynamic exercise, whereas a 22% (P

  5. Cell-cell interaction in blood flow in patients with coronary heart disease (in vitro study)

    Science.gov (United States)

    Malinova, Lidia I.; Simonenko, Georgy V.; Denisova, Tatyana P.; Tuchin, Valery V.

    2007-02-01

    Blood cell-cell and cell-vessel wall interactions are one of the key patterns in blood and vascular pathophysiology. We have chosen the method of reconstruction of pulsative blood flow in vitro in the experimental set. Blood flow structure was studied by PC integrated video camera with following slide by slide analysis. Studied flow was of constant volumetric blood flow velocity (1 ml/h). Diameter of tube in use was comparable with coronary arteries diameter. Glucose solution and unfractured heparin were used as the nonspecial irritants of studied flow. Erythrocytes space structure in flow differs in all groups of patients in our study (men with stable angina pectoris (SAP), myocardial infarction (MI) and practically healthy men (PHM). Intensity of erythrocytes aggregate formation was maximal in patients with SAP, but time of their "construction/deconstruction" at glucose injection was minimal. Phenomena of primary clotting formation in patients with SAP of high function class was reconstructed under experimental conditions. Heparin injection (10 000 ED) increased linear blood flow velocity both in patients with SAP, MI and PHP but modulated the cell profile in the flow. Received data correspond with results of animal model studies and noninvasive blood flow studies in human. Results of our study reveal differences in blood flow structure in patients with coronary heart disease and PHP under irritating conditions as the possible framework of metabolic model of coronary blood flow destabilization.

  6. Brain energy metabolism and blood flow differences in healthy aging

    DEFF Research Database (Denmark)

    Aanerud, Joel; Borghammer, Per; Chakravarty, M Mallar

    2012-01-01

    Cerebral metabolic rate of oxygen consumption (CMRO(2)), cerebral blood flow (CBF), and oxygen extraction fraction (OEF) are important indices of healthy aging of the brain. Although a frequent topic of study, changes of CBF and CMRO(2) during normal aging are still controversial, as some authors...... find decreases of both CBF and CMRO(2) but increased OEF, while others find no change, and yet other find divergent changes. In this reanalysis of previously published results from positron emission tomography of healthy volunteers, we determined CMRO(2) and CBF in 66 healthy volunteers aged 21 to 81......, and in the temporal cortex. Because of the inverse relation between OEF and capillary oxygen tension, increased OEF can compromise oxygen delivery to neurons, with possible perturbation of energy turnover. The results establish a possible mechanism of progression from healthy to unhealthy brain aging, as the regions...

  7. Numerical method of characteristics for one-dimensional blood flow

    CERN Document Server

    Acosta, Sebastian; Riviere, Beatrice; Penny, Daniel J; Rusin, Craig G

    2014-01-01

    Mathematical modeling at the level of the full cardiovascular system requires the numerical approximation of solutions to a one-dimensional nonlinear hyperbolic system describing flow in a single vessel. This model is often simulated by computationally intensive methods like finite elements and discontinuous Galerkin, while some recent applications require more efficient approaches (e.g. for real-time clinical decision support, phenomena occurring over multiple cardiac cycles, iterative solutions to optimization/inverse problems, and uncertainty quantification). Further, the high speed of pressure waves in blood vessels greatly restricts the time-step needed for stability in explicit schemes. We address both cost and stability by presenting an efficient and unconditionally stable method for approximating solutions to diagonal nonlinear hyperbolic systems. Theoretical analysis of the algorithm is given along with a comparison of our method to a discontinuous Galerkin implementation. Lastly, we demonstrate the ...

  8. Cerebral blood flow and oxygen metabolism in the Rett syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Hideto; Fueki, Noboru; Suzuki, Hisaharu; Sakuragawa, Norio; Iio, Masaaki (National Central Hospital for Mental, Nervous and Muscular Disorders, Tokyo (Japan))

    1992-05-01

    Positron emission tomography (PET) was performed on six patients with the Rett syndrome and the results were compared with the concurrent clinical status of the patients. The cerebral metabolic rate of oxygen (CMRO{sub 2}) was low in five patients, and oxygen extraction fraction (OEF) was low in four patients; both had a tendency to decline with advancing age. Although the cause is unknown, it is suggested that impaired oxidative metabolism exists in the Rett syndrome. An analysis of the distribution among brain regions showed that the ratios of values for the frontal cortex to those for the temporal cortex for both the cerebral blood flow (CBF) and CMRO{sub 2} were lower than those for the controls, which may indicate the loss of of hyperfrontality in the Rett syndrome. Distribution of brain metabolism may be immature in the Rett syndrome. (author).

  9. Laser Doppler flowmetry to measure changes in cerebral blood flow.

    Science.gov (United States)

    Sutherland, Brad A; Rabie, Tamer; Buchan, Alastair M

    2014-01-01

    Laser Doppler flowmetry (LDF) is a method by which relative cerebral blood flow (CBF) of the cortex can be measured. Although the method is easy to employ, LDF only measures relative CBF, while absolute CBF cannot be quantified. LDF is useful for investigating CBF changes in a number of different applications including neurovascular and stroke research. This chapter will prepare the reader for rodent experiments using LDF with two preparations. The closed skull preparation can be used to monitor CBF with an intact skull, but in adult rats, thinning of the skull is required to obtain an accurate cortical CBF signal. The open skull preparation requires a craniotomy to expose the surface of the brain and the LDF probe is held close to the surface to measure cerebral perfusion.

  10. A dynamic model of renal blood flow autoregulation

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Marsh, D J

    1994-01-01

    To test whether a mathematical model combining dynamic models of the tubuloglomerular feedback (TGF) mechanism and the myogenic mechanism was sufficient to explain dynamic autoregulation of renal blood flow, we compared model simulations with experimental data. To assess the dynamic characteristics...... nephrons act in parallel, each simulation was performed with 125 parallel versions of the model. The key parameters of the 125 versions of the model were chosen randomly within the physiological range. None of the constituent models, i.e., the TGF and the myogenic, could alone reproduce the experimental...... observations. However, in combination they reproduced most of hte features of the various transfer functions calculated from the experimental data. The major discrepancy was the presence of a bimodal distribution of the admittance phase in the simulations. This is not consistent with most of the experimental...

  11. Peculiarities of Brain's Blood Flow : Role of Carbon Dioxide

    CERN Document Server

    Gersten, Alexander

    2011-01-01

    Among the major factors controlling the cerebral blood flow (CBF), the effect of PaCO2 is peculiar in that it violates autoregulatory CBF mechanisms and allows to explore the full range of the CBF. This research resulted in a simple physical model, with a four parameter formula, relating the CBF to PaCO2. The parameters can be extracted in an easy manner, directly from the experimental data. With this model earlier experimental data sets of Rhesus monkeys and rats were well fitted. Human data were also fitted with this model. Exact formulae were found, which can be used to transform the fits of one animal to the fits of another one. The merit of this transformation is that it enable us the use of rats data as monkeys data simply by rescaling the PaCO2 values and the CBF data. This transformation makes possible the use of experimental animal data instead of human ones.

  12. Biology and Mechanics of Blood Flows Part I: Biology

    CERN Document Server

    Thiriet, Marc

    2008-01-01

    Biology and Mechanics of Blood Flows presents the basic knowledge and state-of-the-art techniques necessary to carry out investigations of the cardiovascular system using modeling and simulation. Part I of this two-volume sequence, Biology, addresses the nanoscopic and microscopic scales. The nanoscale corresponds to the scale of biochemical reaction cascades involved in cell adaptation to mechanical stresses among other stimuli. The microscale is the scale of stress-induced tissue remodeling associated with acute or chronic loadings. The cardiovascular system, like any physiological system, has a complicated three-dimensional structure and composition. Its time dependent behavior is regulated, and this complex system has many components. In this authoritative work, the author provides a survey of relevant cell components and processes, with detailed coverage of the electrical and mechanical behaviors of vascular cells, tissues, and organs. Because the behaviors of vascular cells and tissues are tightly coupl...

  13. Coagulation on biomaterials in flowing blood: some theoretical considerations.

    Science.gov (United States)

    Basmadjian, D; Sefton, M V; Baldwin, S A

    1997-12-01

    Are truly inert biomaterials feasible? Recent mathematical models of coagulation which are reviewed here suggest that such materials are impossible. This conclusion, which is certainly consistent with our collective experimental evidence, arises from the calculation that conversion of Factor XI to XIa never drops to zero even at the highest flow rates and with virtually no Factor XIIa bound to a surface. Residual amounts of XIa are still formed which can in principle kick-off the coagulation cascade. Furthermore, if the flow rates and corresponding mass transfer coefficients are low and in spite of these near-vanishing levels of the initiating coagulants, the surprising result is that substantial amounts of thrombin are produced. On the contrary, under slightly higher flow conditions, there can be more substantial levels of initiating coagulants, yet paradoxically thrombin production is near zero. This article presents a theoretical understanding of the events which take place during the interaction of biomaterials with flowing blood. We follow these events from the time of first contact to the final production of thrombin. The effect of flow and surface activity on the contact phase reactions is examined in detail and the two are found to be intertwined. The common pathway is also examined and here the main feature is the existence of three flow dependent regions which produce either high or very low levels of thrombin, as well as multiple thrombin steady states. In a final analysis we link the two segments of the cascade and consider the events which result. In addition, we note that multiple steady states arise only in the presence of two (thrombin) feedback loops. Single loops or the bare cascade will produce only single steady states. With some imagination one can attribute to the feedback loops the role of providing the cascade with a mechanism to produce high thrombin levels in case of acute need (e.g. bleeding) or to allow levels to subside to 'stand

  14. Doppler Assessment of Uterine Blood Flow in Recurrent Pregnancy Loss

    Directory of Open Access Journals (Sweden)

    Maryam Barzin

    2011-05-01

    Full Text Available Recurrent spontaneous abortion affects 2%-5% of"ncouples. Uterine perfusion is considered as one of the"nfactors that influences the success of implantation."nDuring the normal menstrual cycle, the impedance"nto uterine artery blood flow diminishes progressively"nduring the luteal phase, reaching the lowest values"nin the period coinciding with the implantation time."nImpedance of uterine arteries is a good indicator of"nthe possibility of a subsequent pregnancy. High blood"nflow resistance is associated with a reduced conception"nrate and women with lower pulsatility index values"nhave the highest possibility of becoming pregnant. An"nimpaired uterine perfusion could play a major role in"nthe pathogenesis of recurrent spontaneous abortion. In"nthis study, we examined sixty women with recurrent"nspontaneous abortion and a control group including"nthirty normal women with at least one previous"nuncomplicated pregnancy and without history of any"nabortion. Transvaginal sonography associated with"nDoppler flow measurement was performed during"nthe midluteal phase of a cycle in all women. The"nmeasurement of the ascending branch of both right"nand left uterine arteries was taken lateral to the cervix"nat the level of the internal os. The pulsatility and"nresistance index of both uterine arteries were calculated"nand compared in both groups. In this presentation we"nreport our finding in two groups. We also explain the"nexact method of study and present some interesting"ncases

  15. Nitric oxide and prostaglandins influence local skeletal muscle blood flow during exercise in humans: coupling between local substrate uptake and blood flow

    DEFF Research Database (Denmark)

    Kalliokoski, Kari K; Langberg, Henning; Ryberg, Ann Kathrine;

    2006-01-01

    skeletal muscle. Skeletal muscle blood flow was measured in seven healthy young men using near-infrared spectroscopy and indocyanine green and muscle glucose uptake using positron emission tomography and 2-fluoro-2-deoxy-D-[(18)F]glucose without and with local blockade of NO and PG at rest and during one-legged...... dynamic knee-extension exercise. Local blockade was produced by infusing nitro-L-arginine methyl ester and indomethacin directly in the muscle via a microdialysis catheter. Blood flow and glucose uptake were measured in the region of blockade and in two additional regions of vastus lateralis muscle 1......Synergic action of nitric oxide (NO) and prostaglandins (PG) in the regulation of muscle blood flow during exercise has been demonstrated. In the present study, we investigated whether these vasodilators also regulate local blood flow, flow heterogeneity, and glucose uptake within the exercising...

  16. Role of cerebral blood flow in extreme breath holding

    Directory of Open Access Journals (Sweden)

    Bain Anthony R.

    2016-01-01

    Full Text Available The role of cerebral blood flow (CBF on a maximal breath-hold (BH in ultra-elite divers was examined. Divers (n = 7 performed one control BH, and one BH following oral administration of the non-selective cyclooxygenase inhibitor indomethacin (1.2 mg/kg. Arterial blood gases and CBF were measured prior to (baseline, and at BH termination. Compared to control, indomethacin reduced baseline CBF and cerebral delivery of oxygen (CDO2 by about 26% (p < 0.01. Indomethacin reduced maximal BH time from 339 ± 51 to 319 ± 57 seconds (p = 0.04. In both conditions, the CDO2 remained unchanged from baseline to the termination of apnea. At BH termination, arterial oxygen tension was higher following oral administration of indomethacin compared to control (4.05 ± 0.45 vs. 3.44 ± 0.32 kPa. The absolute increase in CBF from baseline to the termination of apnea was lower with indomethacin (p = 0.01. These findings indicate that the impact of CBF on maximal BH time is likely attributable to its influence on cerebral H+ washout, and therefore central chemoreceptive drive to breathe, rather than to CDO2.

  17. Subcutaneous blood flow in the temporal region of migraine patients

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, K.

    1987-01-01

    Subcutaneous blood flow in the temporal region (TSBF) was measured by the local 133 Xenon washout technique in 43 migraine patients; 19 were reexamined in the course of spontaneous attacks. During attacks, TSBF was normal compared to headache-free state. In 13 unilateral attacks, the median ipsilateral to contralateral ratio TSBF was 1: 1.276, (NS). During 30 deg C passive head-up tilt, TSBF descreased by a median of 27% during headache-free intervals and by a median, 21% during migraine attacks. The difference between the 2 occasions was not significant. Head-up tilt resulted in a median 4.5% increase in mean arterial blood pressure (MAP) and a median 5.3% increase in heart rate (HR) during headache-free intervals and 3.4% and 3.2% respectively during migraine attacks. These results are evidence against a vasomotor disturbance of the extracranial tissues during attacks of migraine. The cardio-vascular response to the orthostatic stimulus indicates a normal function of this part of the autonomic nervous system during migraine attacks.

  18. Simulation of groundwater flow and interaction of groundwater and surface water on the Lac du Flambeau Reservation, Wisconsin

    Science.gov (United States)

    Juckem, Paul F.; Fienen, Michael N.; Hunt, Randall J.

    2014-01-01

    The Lac du Flambeau Band of Lake Superior Chippewa and Indian Health Service are interested in improving the understanding of groundwater flow and groundwater/surface-water interaction on the Lac du Flambeau Reservation (Reservation) in southwest Vilas County and southeast Iron County, Wisconsin, with particular interest in an understanding of the potential for contamination of groundwater supply wells and the fate of wastewater that is infiltrated from treatment lagoons on the Reservation. This report describes the construction, calibration, and application of a regional groundwater flow model used to simulate the shallow groundwater flow system of the Reservation and water-quality results for groundwater and surface-water samples collected near a system of waste-water-treatment lagoons. Groundwater flows through a permeable glacial aquifer that ranges in thickness from 60 to more than 200 feet (ft). Seepage and drainage lakes are common in the area and influence groundwater flow patterns on the Reservation. A two-dimensional, steady-state analytic element groundwater flow model was constructed using the program GFLOW. The model was calibrated by matching target water levels and stream base flows through the use of the parameter-estimation program, PEST. Simulated results illustrate that groundwater flow within most of the Reservation is toward the Bear River and the chain of lakes that feed the Bear River. Results of analyses of groundwater and surface-water samples collected downgradient from the wastewater infiltration lagoons show elevated levels of ammonia and dissolved phosphorus. In addition, wastewater indicator chemicals detected in three downgradient wells and a small downgradient stream indicate that infiltrated wastewater is moving southwest of the lagoons toward Moss Lake. Potential effects of extended wet and dry periods (within historical ranges) were evaluated by adjusting precipitation and groundwater recharge in the model and comparing the

  19. Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans

    DEFF Research Database (Denmark)

    Boushel, R; Langberg, Henning; Green, Stefan Mathias;

    2000-01-01

    1. Circulation around tendons may act as a shunt for muscle during exercise. The perfusion and oxygenation of Achilles' peritendinous tissue was measured in parallel with that of calf muscle during exercise to determine (1) whether blood flow is restricted in peritendinous tissue during exercise......, and (2) whether blood flow is coupled to oxidative metabolism. 2. Seven individuals performed dynamic plantar flexion from 1 to 9 W. Radial artery and popliteal venous blood were sampled for O2, peritendinous blood flow was determined by 133Xe-washout, calf blood flow by plethysmography, cardiac output...... by dye dilution, arterial pressure by an arterial catheter-transducer, and muscle and peritendinous O2 saturation by spatially resolved spectroscopy (SRS). 3. Calf blood flow rose 20-fold with exercise, reaching 44 +/- 7 ml (100 g)-1 min-1 (mean +/- s.e.m. ) at 9 W, while Achilles' peritendinous flow...

  20. Subcutaneous blood flow in man during sleep with continous epdural anaesthesia

    DEFF Research Database (Denmark)

    Sindrup, JH; Petersen, Lars Jelstrup; Kastrup, Jens;

    1996-01-01

    BACKGROUND: Subcutaneous blood flow increases during sleep and we evaluated if this increase is affected by epidural anaesthesia. METHODS: Lower leg subcutaneous blood flow was determined by 133Xenon clearance in ten subjects during continous epidural anaesthesia at L2-L3 including eight hours...... of sleep, while the opper abdominal subcutaneous blood flow served as control. RESULTS: Epidural anaesthesia to the level of the umbilicus was followed by an increase in the lower leg subcutaneous blood flow fra 3.4 (1.8-6.3) to 7.8 (3.6-16.9) ml min-1 (median and range; P...-1 100 g-1 after 34 (29-70) min (Pepidural anaesthesia induced only a temporary increase in lower leg subcutaneous blood flow, it hindered the rise in subcutaneous blood flow normally manifest...

  1. Skeletal blood flow in Paget's disease of bone and its response to calcitonin therapy.

    Science.gov (United States)

    Wootton, R; Reeve, J; Spellacy, E; Tellez-Yudilevich, M

    1978-01-01

    1. Blood flow to the skeleton was measured by the 18F clearance method of Wooton, Reeve & Veall (1976) in 24 patients with untreated Paget's disease. In every patient but one, resting skeletal blood flow was increased. There was a significant positive correlation between skeletal blood flow and serum alkaline phosphatase and between skeletal blood flow and urinary total hydroxyproline excretion. 2. Fourteen patients were re-studied after they had received short-term (7 days or less) or long-term (7 weeks or more) calcitonin. Skeletal blood flow, alkaline phosphatase and urinary hydroxy-proline excretion fell towards normal in every case. There was some evidence from the short-term studies that calcitonin produced a more rapid fall in skeletal blood flow than in alkaline phosphatase. 3. Glomerular filtration rate appeared to increase transiently in response to calcitonin.

  2. Timing and topography of cerebral blood flow, aura, and headache during migraine attacks

    DEFF Research Database (Denmark)

    Olesen, J; Friberg, L; Olsen, T S

    1990-01-01

    and statistically significant spatial relations. The first observable event was a decrease of regional cerebral blood flow posteriorly in one cerebral hemisphere. Further development of this pathological process was accompanied by the aura symptoms. Thereafter headache occurred while regional cerebral blood flow...... remained decreased. During the headache phase, regional cerebral blood flow gradually changed from abnormally low to abnormally high without apparent change in headache. In some patients headache disappeared while regional cerebral blood flow remained increased. Although regional cerebral blood flow...... reduction and aura symptoms in the great majority of patients were unilateral, one-third had bilateral headache. Unilateral headache usually localized to the side on which regional cerebral blood flow was reduced and from which the aura symptoms originated (i.e., aura symptoms were perceived to occur...

  3. Clinical Relevance of Coronary Fractional Flow Reserve: Art-of-state

    Institute of Scientific and Technical Information of China (English)

    Yohanes Adiputra; Shao-Liang Chen

    2015-01-01

    Objective:The objective was to delineate the current knowledge of fractional flow reserve (FFR) in terms of definition,features,clinical applications,and pitfalls of measurement of FFR.Data Sources:We searched database for primary studies published in English.The database of National Library of Medicine (NLM),MEDLINE,and PubMed up to July 2014 was used to conduct a search using the keyword term "FFR".Study Selection:The articles about the definition,features,clinical application,and pitfalls of measurement of FFR were identified,retrieved,and reviewed.Results:Coronary pressure-derived FFR rapidly assesses the hemodynamic significance of individual coronary artery lesions and can readily be performed in the catheterization laboratory.The use of FFR has been shown to effectively guide coronary revascularization procedures leading to improved patient outcomes.Conclusions:FFR is a valuable tool to determine the functional significance of coronary stenosis.It combines physiological and anatomical information,and can be followed immediately by percutaneous coronary intervention (PCI) if necessary.The technique of FFR measurement can be performed easily,rapidly,and safely in the catheterization laboratory.By systematic use of FFR in dubious stenosis and multi-vessel disease,PCI can be made an even more effective and better treatment than it is currently.The current clinical evidence for FFR should encourage cardiologists to use this tool in the catheterization laboratory.

  4. Coronary flow reserve in hypertrophic cardiomyopathy: relation with microvascular dysfunction and pathophysiological characteristics.

    Science.gov (United States)

    Kofflard, M J; Michels, M; Krams, R; Kliffen, M; Geleijnse, M L; Ten Cate, F J; Serruys, P W

    2007-01-01

    BACKGROUND.: The decrease in coronary flow reserve (CFR) in hypertrophic cardiomyopathy (HCM) predisposes to myocardial ischaemia, systolic dysfunction and cardiac death. In this study we investigate to which extent haemodynamic, echocardiographic, and histological parameters contribute to the reduction of CFR. METHODS.: In ten HCM patients (mean age 44+/-14 years) and eight heart transplant (HTX) patients (mean age 51+/-6 years) CFR was calculated in the left anterior descending coronary artery. In all subjects haemodynamic, echocardiographic and histological parameters were assessed. The relationship between these variables and CFR was determined using linear regression analysis. RESULTS.: CFR was reduced in HCM compared with HTX patients (1.6+/-0.7 vs. 2.7+/-0.8, p<0.01). An increase in septal thickness (p<0.005), indexed left ventricular (LV) mass (p<0.005), LV end-diastolic pressure (p<0.001), LV outflow tract gradient (p<0.05) and a decrease in arteriolar lumen size (p<0.05) were all related to a reduction in CFR. CONCLUSION.: In HCM patients haemodynamic (LV end-diastolic pressure, LV outflow tract gradient), echocardiographic (indexed LV mass) and histological (% luminal area of the arterioles) changes are responsible for a decrease in CFR. (Neth Heart J 2007;15:209-15.).

  5. Fractional Flow Reserve-Guided Deferred Versus Complete Revascularization in Patients With Diabetes Mellitus.

    Science.gov (United States)

    Kennedy, Mark W; Hermanides, Rik S; Kaplan, Emel; Hemradj, Veemal; Fabris, Enrico; Koopmans, Petra C; Dambrink, Jan-Henk E; Gosselink, A T Marcel; Van't Hof, Arnoud W J; Ottervanger, Jan Paul; Roolvink, Vincent; Remkes, Wouter S; van der Sluis, Aize; Suryapranata, Harry; Kedhi, Elvin

    2016-11-01

    To assess the safety and efficacy of deferred versus complete revascularization using a fractional flow reserve (FFR)-guided strategy in patients with diabetes mellitus (DM), we analyzed all DM patients who underwent FFR-guided revascularization from January 1, 2010, to December 12, 2013. Patients were divided into 2 groups: those with ≥1 remaining FFR-negative (>0.80) medically treated lesions [FFR(-)MT] and those with only FFR-positive lesions (≤0.80) who underwent complete revascularization [FFR(+)CR] and were followed until July 1, 2015. The primary end point was the incidence of major adverse cardiovascular events (MACE), a composite of death, myocardial infarction (MI), target lesion (FFR assessed) revascularization, and rehospitalization for acute coronary syndrome. A total of 294 patients, 205 (69.7%) versus 89 (30.3%) in FFR(-)MT and FFR(+)CR, respectively, were analyzed. At a mean follow-up of 32.6 ± 18.1 months, FFR(-)MT was associated with higher MACE rate 44.0% versus 26.6% (log-rank p = 0.02, Cox regression-adjusted hazard ratio [HR] 2.01, 95% confidence interval [CI] 1.21 to 3.33, p required to guide our treatment strategy in these patients with high-risk, fast-progressing atherosclerosis.

  6. SPECT myocardial perfusion versus fractional flow reserve for evaluation of functional ischemia: A meta analysis

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Tao; Yang, Lin-feng [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Zhai, Ji-liang [Department of Medical Imaging, The Branch of TaiAn Central Hospital, Middle of Changcheng Road, Shandong Province, China. 271000 (China); Li, Jiang [Department of Medical Imaging, Affiliated Hospital of Taishan Medical University, No, 706, Taishan Road, Shandong Province, China. 271000 (China); Wang, Qi-meng [Department of Medical Imaging, Taishan Hospital of Traditional Chinese Medicine, No, 216, Yingxuan Street, Shandong Province, China. 271000. (China); Zhang, Rui-jie; Wang, Sen; Peng, Zhao-hui [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Li, Min, E-mail: liminyingxiang@163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China); Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No, 25, Shifan Road, Jinan, Shandong Province, China. 250031 (China)

    2014-06-15

    Purpose: The present meta-analysis illustrates the accuracy of myocardial perfusion SPECT (MPS) to diagnose functional stenotic coronary artery disease (CAD) with fractional flow reserve (FFR) as standard reference. Methods: All investigators screened and selected studies that compared MPS with FFR in symptomatic patients with suspected CAD. Patients and study characteristics were independently extracted by two investigators; differences were resolved by consensus. Results: 13 articles, including 1,017 patients, 699 vessels were included in the study. No significant publication bias was detected (P = 0.65). At the patient level, the summary sensitivity and specificity were 77% (95% confidence interval [CI], 70–83%) and 77% (95%CI, 67–84%) for MPS. Vessel-level pooled sensitivity was 66% (95%CI, 57–74%) and specificity was 81% (95%CI, 70–89%). The overall diagnostic performance of MPS was moderate. [The area under the summary receiver operating characteristic (sROC) curve was 0.83]. No study influenced the pooled results larger than 0.03. Conclusions: The accuracy between FFR and MPS SPECT was moderate.

  7. A machine-learning approach for computation of fractional flow reserve from coronary computed tomography.

    Science.gov (United States)

    Itu, Lucian; Rapaka, Saikiran; Passerini, Tiziano; Georgescu, Bogdan; Schwemmer, Chris; Schoebinger, Max; Flohr, Thomas; Sharma, Puneet; Comaniciu, Dorin

    2016-07-01

    Fractional flow reserve (FFR) is a functional index quantifying the severity of coronary artery lesions and is clinically obtained using an invasive, catheter-based measurement. Recently, physics-based models have shown great promise in being able to noninvasively estimate FFR from patient-specific anatomical information, e.g., obtained from computed tomography scans of the heart and the coronary arteries. However, these models have high computational demand, limiting their clinical adoption. In this paper, we present a machine-learning-based model for predicting FFR as an alternative to physics-based approaches. The model is trained on a large database of synthetically generated coronary anatomies, where the target values are computed using the physics-based model. The trained model predicts FFR at each point along the centerline of the coronary tree, and its performance was assessed by comparing the predictions against physics-based computations and against invasively measured FFR for 87 patients and 125 lesions in total. Correlation between machine-learning and physics-based predictions was excellent (0.9994, P computation, average execution time was reduced by more than 80 times, leading to near real-time assessment of FFR. Average execution time went down from 196.3 ± 78.5 s for the CFD model to ∼2.4 ± 0.44 s for the machine-learning model on a workstation with 3.4-GHz Intel i7 8-core processor.

  8. Physiological non-Newtonian blood flow through single stenosed artery

    Science.gov (United States)

    Mamun, Khairuzzaman; Rahman, Mohammad Matiur; Akhter, Most. Nasrin; Ali, Mohammad

    2016-07-01

    A numerical simulation to investigate the Non-Newtonian modelling effects on physiological flows in a three dimensional idealized artery with a single stenosis of 85% severity. The wall vessel is considered to be rigid. Oscillatory physiological and parabolic velocity profile has been imposed for inlet boundary condition. Where the physiological waveform is performed using a Fourier series with sixteen harmonics. The investigation has a Reynolds number range of 96 to 800. Low Reynolds number k - ω model is used as governing equation. The investigation has been carried out to characterize two Non-Newtonian constitutive equations of blood, namely, (i) Carreau and (ii) Cross models. The Newtonian model has also been investigated to study the physics of fluid. The results of Newtonian model are compared with the Non-Newtonian models. The numerical results are presented in terms of pressure, wall shear stress distributions and the streamlines contours. At early systole pressure differences between Newtonian and Non-Newtonian models are observed at pre-stenotic, throat and immediately after throat regions. In the case of wall shear stress, some differences between Newtonian and Non-Newtonian models are observed when the flows are minimum such as at early systole or diastole.

  9. Airway blood flow response to dry air hyperventilation in sheep

    Energy Technology Data Exchange (ETDEWEB)

    Parsons, G.H.; Baile, E.M.; Pare, P.D.

    1986-03-01

    Airway blood flow (Qaw) may be important in conditioning inspired air. To determine the effect of eucapneic dry air hyperventilation (hv) on Qaw in sheep the authors studied 7 anesthetized open-chest sheep after 25 min. of warm dry air hv. During each period of hv the authors have recorded vascular pressures, cardiac output (CO), and tracheal mucosal and inspired air temperature. Using a modification of the reference flow technique radiolabelled microspheres were injected into the left atrium to make separate measurements after humid air and dry air hv. In 4 animals a snare around the left main pulmonary artery was used following microsphere injection to prevent recirculation (entry into L lung of microspheres from the pulmonary artery). Qaw to the trachea and L lung as measured and Qaw for the R lung was estimated. After the final injection the sheep were killed and bronchi (Br) and lungs removed. Qaw (trachea plus L lung plus R lung) in 4 sheep increased from a mean of 30.8 to 67.0 ml/min. Airway mucosal temp. decreased from 39/sup 0/ to 33/sup 0/C. The authors conclude that dry air hv cools airway mucosa and increases Qaw in sheep.

  10. Chronic intestinal ischaemia: measurement of the total splanchnic blood flow.

    Science.gov (United States)

    Zacho, Helle D

    2013-04-01

    A redundant collateral network between the intestinal arteries is present at all times. In case of ischaemia in the gastrointestinal tract, the collateral blood supply can develop further, thus accommodating the demand for oxygen even in the presence of significant stenosis or occlusion of the intestinal arteries without clinical symptoms of intestinal ischaemia. Symptoms of ischemia develop when the genuine and collateral blood supply no longer can accommodate the need for oxygen. Atherosclerosis is the most common cause of obliteration in the intestinal arteries. In chronic intestinal ischaemia (CII), the fasting splanchnic blood flow (SBF) is sufficient, but the postprandial increase in SBF is inadequate and abdominal pain will therefore develop in relation to food intake causing the patient to eat smaller meals at larger intervals with a resulting weight loss. Traditionally, the CII-diagnosis has exclusively been based upon morphology (angiography) of the intestinal arteries; however, substantial discrepancies between CII-symptoms and the presence of atherosclerosis/stenosis in the intestinal arteries have been described repeatedly in the literature impeding the diagnosis of CII. This PhD thesis explores a method to determine the total SBF and its potential use as a diagnostic tool in patients suspected to suffer from CII. The SBF can be measured using a continuous infusion of a tracer and catheterisation of a hepatic vein and an artery. By measuring the SBF before and after a standard meal it is possible to assess the ability or inability to enhance the SBF and thereby diagnosing CII. In Study I, measurement of SBF was tested against angiography in a group of patients suspected to suffer from CII due to pain and weight loss. A very good agreement between the postprandial increase in SBF and angiography was found. The method was validated against a well-established method independent of the hepatic extraction of tracer using pAH in a porcine model (study II

  11. Target heart rate to determine the normal value of coronary flow reserve during dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Rousse Maria G

    2011-04-01

    Full Text Available Abstract Background The determination of coronary flow reserve (CFR is an essential concept at the moment of decision-making in ischemic heart disease. There are several direct and indirect tests to evaluate this parameter. In this sense, dobutamine stress echocardiography is one of the pharmacological method most commonly used worldwide. It has been previously demonstrated that CFR can be determined by this technique. Despite our wide experience with dobutamine stress echocardiography, we ignored the necessary heart rate to consider sufficient the test for the analysis of CFR. For this reason, our main goal was to determine the velocity of coronary flow in each stage of dobutamine stress echocardiography and the heart rate value necessary to double the baseline values of coronary flow velocity in the territory of the left anterior descending (LAD coronary artery. Methods A total of 33 consecutive patients were analyzed. The patients included had low risk for coronary artery disease. All the participants underwent dobutamine stress echocardiography and coronary artery flow velocity was evaluated in the distal segment of LAD coronary artery using transthoracic color-Doppler echocardiography. Results The feasibility of determining CFR in the territory of the LAD during dobutamine stress echocardiography was high: 31/33 patients (94%. Mean CFR was 2.67 at de end of dobutamine test. There was an excellent concordance between delta HR (difference between baseline HR and maximum HR and the increase in the CFR (correlation coefficient 0.84. In this sense, we found that when HR increased by 50 beats, CFR was ≥ 2 (CI 93-99.2%. In addition, 96.4% of patients reached a CFR ≥ 2 (IC 91.1 - 99% at 75% of their predicted maximum heart rate. Conclusions We found that the feasibility of dobutamine stress echocardiography to determine CFR in the territory of the LAD coronary artery was high. In this study, it was necessary to achieve a difference of 50 bpm

  12. Extraction of the magnetohydrodynamic blood flow potential from the surface electrocardiogram in magnetic resonance imaging.

    Science.gov (United States)

    Nijm, Grace M; Swiryn, Steven; Larson, Andrew C; Sahakian, Alan V

    2008-07-01

    The magnetohydrodynamic effect generates voltages related to blood flow, which are superimposed on the electrocardiogram (ECG) used for gating during cardiac magnetic resonance imaging (MRI). A method is presented for extracting the magnetohydrodynamic signal from the ECG. The extracted magnetohydrodynamic blood flow potential may be physiologically meaningful due to its relationship to blood flow. Removal of the magnetohydrodynamic voltages from the ECG can potentially lead to improved gating and diagnostically useful ECGs.

  13. The application of blood flow measurements to the study of aging muscle.

    Science.gov (United States)

    McCully, K K; Posner, J D

    1995-11-01

    Blood flow to skeletal muscle is a potentially important factor in the reduction of muscle function associated with aging (sarcopenia). The main influence of reduced blood flow capacity on muscle function is in limiting oxidative metabolism. Direct measures of blood flow include: intravital-microscopy, plethysmography, radioactive microspheres, 133Xenon washout, thermodilution, and Doppler ultrasound. Indirect measurement of blood flow includes arm-to-ankle pressure index and the rate of phosphocreatine recovery after exercise. Several new methodologies have been developed to evaluate muscle blood flow, including color-Doppler imaging, magnetic resonance imaging/angiography (MRI/MRA), and near-infrared spectroscopy (NIRS). As adaptations of traditional techniques, these methods promise more precise information under less invasive conditions. MRI is an expensive and technically challenging method able to measure vessel location, blood flow, and wall diameter in blood vessels throughout the cardiac cycle. Color-Doppler provides excellent temporal resolution blood flow throughout the cardiac cycle, along with some anatomical information. NIRS is an inexpensive and portable technology that can measure changes in oxygen saturation and provide information on tissue oxygen delivery in studies of frailer and more difficult-to-study subjects. Muscle blood flow is not thought to limit oxidative metabolism under normal conditions in young individuals. However, it is not clear what happens to muscle blood flow in healthy older individuals. Reduced capillary density, less maximal blood flow, and a slower hyperemic flow response have been reported in some, but not all, studies. Further studies with the newer methodologies are needed to re-examine age-related changes in muscle blood flow.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Skin and muscle components of forearm blood flow in directly heated resting man.

    Science.gov (United States)

    Detry, J.-M. R.; Brengelmann, G. L.; Rowell, L. B.; Wyss, C.

    1972-01-01

    Changes in forearm muscle blood flow (FMBF) during direct whole-body heating were measured in 17 normal subjects using three different methods. We conclude that FMBF is not increased by direct whole-body heating. Since renal and splanchnic blood flow fall 30% under these conditions, maximal total skin blood flow in 12 previously studied subjects can be estimated from the rise in cardiac output to be 7.6 L/min (3.0-11.1 L/min).

  15. BIFURCATION OF FLOW AND MASS TRANSPORT IN A CURVED BLOOD VESSEL

    Institute of Scientific and Technical Information of China (English)

    TAN Wenchang(谭文长); WEI Lan(魏兰); ZHAO Yaohua(赵耀华); TAKASHI Masuoka

    2003-01-01

    A numerical analysis of flow and concentration fields of macromolecules in a slightly curved blood vessel was carried out. Based on these results, the effect of the bifurcation of a flow on the mass transport in a curved blood vessel was discussed. The macromolecules turned out to be easier to deposit in the inner part of the curved blood vessel near the critical Dean number. Once the Dean number is higher than the critical number, the bifurcation of the flow appears. This bifurcation can prevent macromolecules from concentrating in the inner part of the curved blood vessel. This result is helpful for understanding the possible correlations between the blood dynamics and atherosclerosis.

  16. Exercise intensity modulates the change in cerebral blood flow following aerobic exercise in chronic stroke.

    Science.gov (United States)

    Robertson, Andrew D; Crane, David E; Rajab, A Saeed; Swardfager, Walter; Marzolini, Susan; Shirzadi, Zahra; Middleton, Laura E; MacIntosh, Bradley J

    2015-08-01

    The mechanisms supporting functional improvement by aerobic exercise following stroke remain incompletely understood. This study investigated how cycling intensity and aerobic fitness influence cerebral blood flow (CBF) following a single exercise session. Thirteen community-living stroke survivors performed 20 min of semi-recumbent cycling at low and moderate intensities (40-50 and 60-70 % of heart rate reserve, respectively) as determined from an exercise stress test. CBF was quantified by arterial spin labeling MRI at baseline, as well as 30 and 50 min post-exercise. An intensity-dependent effect was observed in the right post-central and supramarginal gyri up to 50 min after exercise (uncorrected p Aerobic fitness was directly related to posterior cingulate and thalamic CBF, and inversely related to precuneal CBF at rest (R (2) ≥ 0.75); however, no relationship between fitness and the post-exercise change in CBF was observed. Divergent changes in regional CBF were observed in the right parietal cortex following low- and moderate-intensity exercise, which suggests that intensity of prescribed exercise may be useful in optimizing rehabilitation.

  17. Quantitative retinal blood flow mapping from fluorescein videoangiography using tracer kinetic modeling.

    Science.gov (United States)

    Tichauer, Kenneth M; Guthrie, Micah; Hones, Logan; Sinha, Lagnojita; St Lawrence, Keith; Kang-Mieler, Jennifer J

    2015-05-15

    Abnormal retinal blood flow (RBF) has been associated with numerous retinal pathologies, yet existing methods for measuring RBF predominantly provide only relative measures of blood flow and are unable to quantify volumetric blood flow, which could allow direct patient to patient comparison. This work presents a methodology based on linear systems theory and an image-based arterial input function to quantitatively map volumetric blood flow from standard fluorescein videoangiography data, and is therefore directly translatable to the clinic. Application of the approach to fluorescein retinal videoangiography in rats (4 control, 4 diabetic) demonstrated significantly higher RBF in 4-5 week diabetic rats as expected from the literature.

  18. Modeling cerebral blood flow during posture change from sitting to standing

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, M.; Tran, H.T.

    2004-01-01

    extremities, the brain, and the heart. We use physiologically based control mechanisms to describe the regulation of cerebral blood flow velocity and arterial pressure in response to orthostatic hypotension resulting from postural change. To justify the fidelity of our mathematical model and control......Abstract Hypertension, decreased cerebral blood flow, and diminished cerebral blood flow velocity regulation, are among the first signs indicating the presence of cerebral vascular disease. In this paper, we will present a mathematical model that can predict blood flow and pressure during posture...

  19. Noninvasive color Doppler sonography of uterine blood flow throughout pregnancy in sheep and goats.

    Science.gov (United States)

    Elmetwally, M; Rohn, K; Meinecke-Tillmann, S

    2016-04-01

    In contrast to cattle or horses, uterine blood flow in small ruminants has been investigated predominantly after surgical intervention and chronic instrumentation. The objective of the present study was to investigate the clinical applicability of noninvasive color Doppler sonography to characterize blood flow in the maternal uterine artery of sheep, n = 11 (18 pregnancies) and goats, n = 11 (20 pregnancies). The following parameters were measured transrectally or transabdominally: blood flow volume, time-averaged maximum velocity (TAMV), resistance index (RI), pulsatility index (PI), Time-averaged mean velocity, impedance of blood flow (AB or systolic/diastolic [S/D] velocity ratio), peak velocity of blood flow and blood flow acceleration. Examinations started 2 weeks after breeding and continued at 2-week intervals until parturition. Outcomes for sheep and goats were similar and will be discussed together. Based on noninvasive color Doppler sonography, blood flow volume increased (approximately 60-fold, P sheep and goats. Furthermore, for uterine artery blood flow, there was an effect of stage of pregnancy on PI and RI (P sheep and goats, respectively, and then decreased until parturition. Similar to PI and RI, vascular impedance of the uterine decreased (P < 0.0001) throughout pregnancy. This is apparently the first study using noninvasive color Doppler sonography of uterine blood flow throughout physiological pregnancy in small ruminants. Clearly, this technology facilitates repeated, noninvasive assessments, with great potential for future studies.

  20. Mathematical analysis of non-Newtonian blood flow in stenosis narrow arteries.

    Science.gov (United States)

    Sriyab, Somchai

    2014-01-01

    The flow of blood in narrow arteries with bell-shaped mild stenosis is investigated that treats blood as non-Newtonian fluid by using the K-L model. When skin friction and resistance of blood flow are normalized with respect to non-Newtonian blood in normal artery, the results present the effect of stenosis length. When skin friction and resistance of blood flow are normalized with respect to Newtonian blood in stenosis artery, the results present the effect of non-Newtonian blood. The effect of stenosis length and effect of non-Newtonian fluid on skin friction are consistent with the Casson model in which the skin friction increases with the increase of either stenosis length or the yield stress but the skin friction decreases with the increase of plasma viscosity coefficient. The effect of stenosis length and effect of non-Newtonian fluid on resistance of blood flow are contradictory. The resistance of blood flow (when normalized by non-Newtonian blood in normal artery) increases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length. The resistance of blood flow (when normalized by Newtonian blood in stenosis artery) decreases when either the plasma viscosity coefficient or the yield stress increases, but it decreases with the increase of stenosis length.

  1. MEASUREMENT OF REGIONAL BONE BLOOD FLOW IN THE CANINE MANDIBULAR RAMUS USING RADIOLABELLED TOAD RED BLOOD CELLS

    Institute of Scientific and Technical Information of China (English)

    毛驰; 王翰章

    1994-01-01

    Toad red blood cells were used to measure regional bone blood flow in the canine mandibular ramus.The blood cells were labelled with sodium pertechnetate and fixed in 10% formalin;they were 22×15 μm in size and had a specific gravity close to that of dog red blood cells.These cells had no discernible effect on systemic hemody-namics after injection,did not agglutinate,were well mixed and evenly distributed throughout the body,and were completely extracted in one circulation through the mandible.The mandibular ramus was divided into six regions,and the blood flow rates in each were found to be similar to those reported in previous studies with radiolabelled carbonized,microspheres.Furthermore,the blood flow distribution pattern of the mandibular ramus determined in this study was identical to that of our previous study using the bone-seeking radionuclide method.We suggest that radiolabelled toad red blood cells are an ideal marker for measuring regional blood flow in the canine mandible.

  2. Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement.

    Science.gov (United States)

    Trauzeddel, Ralf Felix; Löbe, Ulrike; Barker, Alex J; Gelsinger, Carmen; Butter, Christian; Markl, Michael; Schulz-Menger, Jeanette; von Knobelsdorff-Brenkenhoff, Florian

    2016-03-01

    Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p flow than controls (p blood flow eccentricity (64.7 and 66.7%, respectively), whereas controls showed central blood flow (88.9%). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.

  3. Effects of friction massage of the popliteal fossa on blood flow velocity of the popliteal vein

    Science.gov (United States)

    Iwamoto, Koji; Mizukami, Masafumi; Asakawa, Yasutsugu; Endo, Yusuke; Takata, Yuichi; Yoshikawa, Kenichi; Yoshio, Masaharu

    2017-01-01

    [Purpose] Friction massage (friction) of the popliteal fossa is provided for the purpose of relieving pain related to circulatory disorders by improving venous flow in the lower legs. The purpose of this study is to verify the effects of enhancing the venous flow based on measuring the blood flow velocity of the popliteal vein before and after providing friction to the patients. [Subjects and Methods] Fifteen healthy male university students participated in the study. The Doppler ultrasonography (DU) was used to measure the blood flow velocity of the popliteal vein, in order to verify the effects of enhancing the venous flow by comparing the measured values before and after a friction massage. [Results] The result of comparing the blood flow velocity before and after providing friction showed that there was a significant increase after friction. [Conclusion] This study proved that friction to the popliteal fossa is effectively enhances venous flow by increasing the blood flow velocity in the popliteal vein.

  4. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  5. Cerebral blood flow in Alzheimer’s disease

    Directory of Open Access Journals (Sweden)

    Roher AE

    2012-10-01

    Full Text Available Alex E Roher,1 Josef P Debbins,2 Michael Malek-Ahmadi,3 Kewei Chen,4 James G Pipe,2 Sharmeen Maze,2 Christine Belden,3 Chera L Maarouf,1 Pradeep Thiyyagura,4 Hua Mo,4 Jesse M Hunter,1 Tyler A Kokjohn,1,5 Douglas G Walker,6 Jane C Kruchowsky,6 Marek Belohlavek,7 Marwan N Sabbagh,3 Thomas G Beach81The Longtine Center for Neurodegenerative Biochemistry, Banner Sun Health Research Institute, Sun City, 2Keller Center for Imaging Innovation, Neuroimaging Research, Barrow Neurological Institute, Phoenix, 3Cleo Roberts Center for Clinical Research, Banner Sun Health Research Institute, Sun City, 4Computational Image Analysis Program, Banner Alzheimer’s Institute, Phoenix, 5Department of Microbiology, Midwestern University, Glendale, 6Laboratory of Neuroinflammation, Banner Sun Health Research Institute, Sun City, 7Division of Cardiovascular Diseases, Mayo Clinic, Scottsdale, 8Civin Laboratory for Neuropathology, Banner Sun Health Research Institute, Sun City, AZ, USABackground: Alzheimer’s disease (AD dementia is a consequence of heterogeneous and complex interactions of age-related neurodegeneration and vascular-associated pathologies. Evidence has accumulated that there is increased atherosclerosis/arteriosclerosis of the intracranial arteries in AD and that this may be additive or synergistic with respect to the generation of hypoxia/ischemia and cognitive dysfunction. The effectiveness of pharmacologic therapies and lifestyle modification in reducing cardiovascular disease has prompted a reconsideration of the roles that cardiovascular disease and cerebrovascular function play in the pathogenesis of dementia.Methods: Using two-dimensional phase-contrast magnetic resonance imaging, we quantified cerebral blood flow within the internal carotid, basilar, and middle cerebral arteries in a group of individuals with mild to moderate AD (n = 8 and compared the results with those from a group of age-matched nondemented control (NDC subjects (n = 9

  6. Vascular Function and Regulation of Blood Flow in Resting and Contracting Skeletal Muscle

    DEFF Research Database (Denmark)

    Nyberg, Michael Permin

    in the regulation of exercise hyperemia. Furthermore, blood flow to contracting leg skeletal muscles is reduced both in essential hypertension and with aging. The potential difference in vasoactive system(s) responsible for the reduction in blood flow in the two conditions is in agreement with the suggestion......The precise matching of blood flow, oxygen delivery and metabolism is essential as it ensures that any increase in muscle work is precisely matched by increases in oxygen delivery. Therefore, understanding the control mechanisms of skeletal muscle blood flow regulation is of great biological...... importance. The present work provides new insight in to vasodilator interactions important for exercise hyperemia and sheds light on mechanisms important for vascular function and regulation of skeletal muscle blood flow in essential hypertension (high blood pressure) and aging and identifies mechanisms...

  7. Uteroplacental blood flow measured by placental scintigraphy during epidural anaesthesia for caesarean section

    Energy Technology Data Exchange (ETDEWEB)

    Skjoeldebrand, A.; Eklund, J.; Johansson, H.; Lunell, N.-O.; Nylund, L.; Sarby, B.; Thornstroem, S. (Departments of Anaesthesiology, Obstetrics and Gynaecology and Medical Physics, Karolinska Institute at Huddinge University Hospital, Stockholm (Sweden))

    1990-01-01

    The uteroplacental blood flow was measured before and during epidural anaesthesia for caesarean section in 11 woman. The blood flow was measured with dynamic placental scintigraphy. After an i.v. injection of indium-113m chloride, the gamma radiation over the placenta was recorded with a computer-linked scintillation camera. The uteroplacental blood flow could be calculated from the isotope accumulation curve. The anaesthesia was performed with bupivacaine plain 0.5%, 18-22 ml and a preload of a balanced electrolyte solution 10 ml/kg b.w. was given. The placental blood flow decreased in eight patients and increased in three with a median change of -21%, not being statistically significant. No correlation between maternal blood pressure and placental blood flow was found. (author).

  8. Coupling between arterial and venous cerebral blood flow during postural change.

    Science.gov (United States)

    Ogoh, Shigehiko; Washio, Takuro; Sasaki, Hiroyuki; Petersen, Lonnie G; Secher, Niels H; Sato, Kohei

    2016-12-01

    In supine humans the main drainage from the brain is through the internal jugular vein (IJV), but the vertebral veins (VV) become important during orthostatic stress because the IJV is partially collapsed. To identify the effect of this shift in venous drainage from the brain on the cerebral circulation, this study addressed both arterial and venous flow responses in the "anterior" and "posterior" parts of the brain when nine healthy subjects (5 men) were seated and flow was manipulated by hyperventilation and inhalation of 6% carbon dioxide (CO2). From a supine to a seated position, both internal carotid artery (ICA) and IJV blood flow decreased (P = 0.004 and P = 0.002), while vertebral artery (VA) flow did not change (P = 0.348) and VV flow increased (P = 0.024). In both supine and seated positions the ICA response to manipulation of end-tidal CO2 tension was reflected in IJV (r = 0.645 and r = 0.790, P blood flow (r = 0.771 and r = 0.828, P blood flow did not affect venous outflow, but the decrease in IJV blood flow was associated with the increase in VV blood flow (r = 0.479, P = 0.044). In addition, the increase in VV blood flow when seated was reflected in VA blood flow (r = 0.649, P = 0.004), and the two flows were coupled during manipulation of the end-tidal CO2 tension (supine, r = 0.551, P = 0.004; seated, r = 0.612, P blood flow when seated and that VV may influence VA blood flow.

  9. Numerical Modeling of Interstitial Fluid Flow Coupled with Blood Flow through a Remodeled Solid Tumor Microvascular Network.

    Directory of Open Access Journals (Sweden)

    M Soltani

    Full Text Available Modeling of interstitial fluid flow involves processes such as fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. To date, majority of microvascular flow modeling has been done at different levels and scales mostly on simple tumor shapes with their capillaries. However, with our proposed numerical model, more complex and realistic tumor shapes and capillary networks can be studied. Both blood flow through a capillary network, which is induced by a solid tumor, and fluid flow in tumor's surrounding tissue are formulated. First, governing equations of angiogenesis are implemented to specify the different domains for the network and interstitium. Then, governing equations for flow modeling are introduced for different domains. The conservation laws for mass and momentum (including continuity equation, Darcy's law for tissue, and simplified Navier-Stokes equation for blood flow through capillaries are used for simulating interstitial and intravascular flows and Starling's law is used for closing this system of equations and coupling the intravascular and extravascular flows. This is the first study of flow modeling in solid tumors to naturalistically couple intravascular and extravascular flow through a network. This network is generated by sprouting angiogenesis and consisting of one parent vessel connected to the network while taking into account the non-continuous behavior of blood, adaptability of capillary diameter to hemodynamics and metabolic stimuli, non-Newtonian blood flow, and phase separation of blood flow in capillary bifurcation. The incorporation of the outlined components beyond the previous models provides a more realistic prediction of interstitial fluid flow pattern in solid tumors and surrounding tissues. Results predict higher interstitial pressure, almost two times, for realistic model compared to the simplified model.

  10. Intensive blood pressure lowering increases cerebral blood flow in older subjects with hypertension.

    Science.gov (United States)

    Tryambake, Dinesh; He, Jiabao; Firbank, Michael J; O'Brien, John T; Blamire, Andrew M; Ford, Gary A

    2013-06-01

    Hypertension is associated with reduced cerebral blood flow (CBF). Intensive (blood pressure (BP) lowering in older people might give greater reduction in cardiovascular risk, but there are concerns that this might produce hypoperfusion which may precipitate falls and possibly stroke. We determined the effect of intensive compared with usual BP lowering on CBF in hypertensive older subjects. Individuals aged >70 years with a history of systolic hypertension on 1 or no BP lowering drugs were recruited from primary care (n=37; age, 75±4 years; systolic BP, >150 mm Hg) and randomized to receive intensive (target BP, treatment. Baseline BP (ambulatory or in clinic) and baseline gray matter CBF were not significantly different between the groups. After treatment, BP was reduced significantly in both groups but fell more in the intensive group (26/17 versus 15/5 mm Hg; Phypertension increases CBF, compared with BP lowering to usual target. These findings suggest hypertension in older people shifts the autoregulatory CBF curve rightward and downward and is reversible with BP lowering.

  11. Comparison of instruments for investigation of microcirculatory blood flow and red blood cell concentration

    Science.gov (United States)

    O'Doherty, Jim; McNamara, Paul; Clancy, Neil T.; Enfield, Joey G.; Leahy, Martin J.

    2009-05-01

    The use of laser Doppler perfusion imaging (LDPI) and laser speckle perfusion imaging (LSPI) is well known in the noninvasive investigation of microcirculatory blood flow. This work compares the two techniques with the recently developed tissue viability (TiVi) imaging system, which is proposed as a useful tool to quantify red blood cell concentration in microcirculation. Three systems are evaluated with common skin tests such as the use of vasodilating and vasoconstricting drugs (methlynicotinate and clobetasol, respectively) and a reactive hyperaemia maneuver (using a sphygmomanometer). The devices investigated are the laser Doppler line scanner (LDLS), the laser speckle perfusion imager (FLPI)-both from Moor Instruments (Axminster, United Kingdom)-and the TiVi imaging system (WheelsBridge AB, Linköping, Sweden). Both imaging and point scanning by the devices are used to quantify the provoked reactions. Perfusion images of vasodilatation and vasoconstriction are acquired with both LDLS and FLPI, while TiVi images are acquired with the TiVi imager. Time acquisitions of an averaged region of interest are acquired for temporal studies such as the reactive hyperaemia. In contrast to the change in perfusion over time with pressure, the TiVi imager shows a different response due its measurement of blood concentration rather than perfusion. The responses can be explained by physiological understanding. Although the three devices sample different compartments of tissue, and output essentially different variables, comparisons can be seen between the three systems. The LDLS system proves to be suited to measurement of perfusion in deeper vessels, while FLPI and TiVi showed sensitivity to more superficial nutritional supply. LDLS and FLPI are insensitive to the action of the vasoconstrictor, while TiVi shows the clear boundaries of the reaction. Assessment of the resolution, penetration depth, and acquisition rate of each instrument show complimentary features that should

  12. In vivo analysis of physiological 3D blood flow of cerebral veins

    Energy Technology Data Exchange (ETDEWEB)

    Schuchardt, Florian; Schroeder, Laure; Baeuerle, Jochen; Harloff, Andreas [University Medical Centre, Department of Neurology, Freiburg (Germany); Anastasopoulos, Constantin [University Medical Center, Department of Neuropaediatrics and Muscle Disorders, Freiburg (Germany); University Medical Centre, Department of Neuroradiology, Freiburg (Germany); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine and McCormick School of Engineering, Chicago, IL (United States); Hennemuth, Anja; Drexl, Johann [Fraunhofer MEVIS, Bremen (Germany); Valdueza, Jose M. [Neurological Center, Segeberger Kliniken, Bad Segeberg (Germany); Mader, Irina [University Medical Centre, Department of Neuroradiology, Freiburg (Germany)

    2015-08-15

    To visualize and quantify physiological blood flow of intracranial veins in vivo using time-resolved, 3D phase-contrast MRI (4D flow MRI), and to test measurement accuracy. Fifteen healthy volunteers underwent repeated ECG-triggered 4D flow MRI (3 Tesla, 32-channel head coil). Intracranial venous blood flow was analysed using dedicated software allowing for blood flow visualization and quantification in analysis planes at the superior sagittal, straight, and transverse sinuses. MRI was evaluated for intra- and inter-observer agreement and scan-rescan reproducibility. Measurements of the transverse sinuses were compared with transcranial two-dimensional duplex ultrasound. Visualization of 3D blood flow within cerebral sinuses was feasible in 100 % and within at least one deep cerebral vein in 87 % of the volunteers. Blood flow velocity/volume increased along the superior sagittal sinus and was lower in the left compared to the right transverse sinus. Intra- and inter-observer reliability and reproducibility of blood flow velocity (mean difference 0.01/0.02/0.02 m/s) and volume (mean difference 0.0002/-0.0003/0.00003 l/s) were good to excellent. High/low velocities were more pronounced (8 % overestimation/9 % underestimation) in MRI compared to ultrasound. Four-dimensional flow MRI reliably visualizes and quantifies three-dimensional cerebral venous blood flow in vivo and is promising for studies in patients with sinus thrombosis and related diseases. (orig.)

  13. Fast Blood Vector Velocity Imaging using ultrasound: In-vivo examples of complex blood flow in the vascular system

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Udesen, Jesper; Gran, Fredrik;

    2008-01-01

    speckle tracking between segments in consecutive speckle images. The flow patterns of six bifurcations and two veins were investigated in-vivo. It was shown: 1) that a stable vortex in the carotid bulb was present opposed to other examined bifurcations, 2) that retrograde flow was present......Conventional ultrasound methods for acquiring color flow images of the blood motion are restricted by a relatively low frame rate and angle dependent velocity estimates. The Plane Wave Excitation (PWE) method has been proposed to solve these limitations. The frame rate can be increased, and the 2-D...... vector velocity of the blood motion can be estimated. The transmitted pulse is not focused, and a full speckle image of the blood can be acquired for each emission. A 13 bit Barker code is transmitted simultaneously from each transducer element. The 2-D vector velocity of the blood is found using 2-D...

  14. Influence of routine assessment of fractional flow reserve on decision making during coronary interventions.

    Science.gov (United States)

    Sant'Anna, Fernando M; Silva, Expedito E R; Batista, Leonardo Alves; Ventura, Fábio Machado; Barrozo, Carlos Alberto Mussel; Pijls, Nico H J

    2007-02-15

    In complex coronary artery disease, it is sometimes difficult to determine which lesions are associated with reversible ischemia and should be stented. Fractional flow reserve (FFR) is an established objective methodology to indicate which lesions produce ischemia. Despite this, the selection of lesions to be stented is often based on the subjectively interpreted angiogram alone. The aim of this study in patients admitted for elective percutaneous intervention (PCI) was to evaluate the change in strategy if the decision to intervene was based on FFR measurement rather than on angiographic assessment. Two hundred fifty consecutive patients (471 arteries) scheduled for PCI were included in this study. All stenoses >or=50% by visual estimation and initially selected to be stented by 3 independent reviewers were assessed by FFR measurements. If FFR was or=0.75, no interventional treatment was given. Optimal pressure measurements were obtained in 452 lesions (96%). Diameter stenosis was 62 +/- 12%, and FFR was 0.67 +/- 0.17 for the entire group. In 68% of the stenoses, initial strategy as assessed from the angiogram was followed, and in 32%, there was a change in the planned approach based on FFR. In 48% of the patients, there was >or=1 lesion in which the treatment decision was changed after physiologic measurements. In conclusion, in this prospective, nonselective, but complete study representing the real world of PCI, 32% of the coronary stenoses and 48% of patients would have received a different treatment if the decision had been based on angiography only, stressing the utility of physiologic assessment in refining decision making during PCI.

  15. Determining tumor blood flow parameters from dynamic image measurements

    Science.gov (United States)

    Libertini, Jessica M.

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth[l]. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community[2], this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake[3]. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  16. Determining tumor blood flow parameters from dynamic image measurements

    Energy Technology Data Exchange (ETDEWEB)

    Libertini, Jessica M [Division of Applied Mathematics, Brown University, Providence, Rhode Island 02906 (United States)], E-mail: Jessica_Libertini@brown.edu

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community, this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  17. Blood flow dynamics, atherosclerosis and bypass graft failure.

    Science.gov (United States)

    Langille, B L; Ojha, M

    1997-05-01

    Atherosclerosis occurs at reproducible sites in the arterial tree and intimal proliferation that leads to bypass graft occlusion also show a well-defined focal distribution. These observations have led to the hypothesis that local blood flow conditions, especially low or fluctuating shear stresses, are important in the development of both disorders. Basic research using both cell culture and animal models has revealed that endothelial cell biology is very sensitive to local shear stresses and rapid progress is being made in characterizing how endothelial cells transduce shear stress. Endothelial sensitivity to shear stress affects control of hemostasis, leukocyte adherence and transmigration, growth factor production, vasomotor responses, endothelial repair and arterial wall remodeling, all of which can be expected to influence development of vascular pathologies. Also, substantial progress has been made in characterizing complex local hemodynamics at relevant arterial sites; however, further progress is needed in this area, as well as in the extrapolation of advances in basic vascular biology to human vascular disease. (Trends Cardiovasc Med 1997;7:111-118). © 1997, Elsevier Science Inc.

  18. Autoregulation of cerebral blood flow in experimental focal brain ischemia.

    Science.gov (United States)

    Dirnagl, U; Pulsinelli, W

    1990-05-01

    The relationship between systemic arterial pressure (SAP) and neocortical microcirculatory blood-flow (CBF) in areas of focal cerebral ischemia was studied in 15 spontaneously hypertensive rats (SHRs) anesthetized with halothane (0.5%). Ischemia was induced by ipsilateral middle cerebral artery/common carotid artery occlusion and CBF was monitored continuously in the ischemic territory using laser-Doppler flowmetry during manipulation of SAP with I-norepinephrine (hypertension) or nitroprusside (hypotension). In eight SHRs not subjected to focal ischemia, we demonstrated that 0.5% halothane and the surgical manipulations did not impair autoregulation. Autoregulation was partly preserved in ischemic brain tissue with a CBF of greater than 30% of preocclusion values. In areas where ischemic CBF was less than 30% of preocclusion values, autoregulation was completely lost. Changes in SAP had a greater influence on CBF in tissue areas where CBF ranged from 15 to 30% of baseline (9% change in CBF with each 10% change in SAP) than in areas where CBF was less than 15% of baseline (6% change in CBF with each 10% change in SAP). These findings demonstrate that the relationship between CBF and SAP in areas of focal ischemia is highly dependent on the severity of ischemia. Autoregulation is lost in a gradual manner until CBF falls below 30% of normal. In areas without autoregulation, the slope of the CBF/SAP relationship is inversely related to the degree of ischemia.

  19. Cerebral blood flow in sickle cell cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Huttenlocher, P.R.; Moohr, J.W.; Johns, L.; Brown, F.D.

    1984-05-01

    Cerebral blood flow (CBF) has been studied by the xenon-133 (/sup 133/Xe) inhalation method in 16 children with suspected sickle cell cerebrovascular disease. Abnormalities consisting of decreases in total, hemispheral, or regional CBF were found in 17 of 26 studies. Eleven studies performed immediately after stroke, transient ischemic attack, or depression of state of alertness showed abnormalities. In addition to confirming regional cerebrovascular insufficiency in children with stroke due to major cerebral artery occlusion, the method detected diffuse decrease in CBF in children with stupor, coma, and seizures who had normal angiographic findings. In contrast, six of seven studies obtained after exchange transfusion or during maintenance on hypertransfusion therapy showed normal findings. The difference between results in patients with acute neurologic disturbances and those receiving transfusion therapy was statistically significant (P less than .005). The data indicate that the /sup 133/Xe method reliably demonstrates cerebrovascular impairment in sickle cell disease. They also suggest that CBF changes in patients with sickle cell disease can be reversed by exchange transfusion and by hypertransfusion therapy. The /sup 133/Xe CBF method may be useful for following up children with sickle cell disease who are at high risk for recurrent stroke.

  20. Unveiling astrocytic control of cerebral blood flow with optogenetics.

    Science.gov (United States)

    Masamoto, Kazuto; Unekawa, Miyuki; Watanabe, Tatsushi; Toriumi, Haruki; Takuwa, Hiroyuki; Kawaguchi, Hiroshi; Kanno, Iwao; Matsui, Ko; Tanaka, Kenji F; Tomita, Yutaka; Suzuki, Norihiro

    2015-06-16

    Cortical neural activities lead to changes in the cerebral blood flow (CBF), which involves astrocytic control of cerebrovascular tone. However, the manner in which astrocytic activity specifically leads to vasodilation or vasoconstriction is difficult to determine. Here, cortical astrocytes genetically expressing a light-sensitive cation channel, channelrhodopsin-2 (ChR2), were transcranially activated with a blue laser while the spatiotemporal changes in CBF were noninvasively monitored with laser speckle flowgraphy in the anesthetised mouse cortex. A brief photostimulation induced a fast transient increase in CBF. The average response onset time was 0.7 ± 0.7 sec at the activation foci, and this CBF increase spread widely from the irradiation spot with an apparent propagation speed of 0.8-1.1 mm/sec. The broad increase in the CBF could be due to a propagation of diffusible vasoactive signals derived from the stimulated astrocytes. Pharmacological manipulation showed that topical administration of a K(+) channel inhibitor (BaCl2; 0.1-0.5 mM) significantly reduced the photostimulation-induced CBF responses, which indicates that the ChR2-evoked astrocytic activity involves K(+) signalling to the vascular smooth muscle cells. These findings demonstrate a unique model for exploring the role of the astrocytes in gliovascular coupling using non-invasive, time-controlled, cell-type specific perturbations.

  1. Analysis of Systolic Backflow and Secondary Helical Blood Flow in the Ascending Aorta Using Vector Flow Imaging

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper

    2016-01-01

    Secondary rotational flow and systolic backflow are seen in the ascending aorta and, in this study, were analyzed with the vector velocity method transverse oscillation. Twenty-five patients were scanned intra-operatively, and the vector velocities were related to estimates of transesophageal...... that backflow is injurious and that secondary flow is a normal flow phenomenon. The study also shows that transverse oscillation can provide new information on blood flow in the ascending aorta....

  2. Blood flow dynamics and sensitivity in breasts after reconstruction with DIEP-flap.

    Science.gov (United States)

    Klasson, Stina; Svensson, Karin; Wollmer, Per; Velander, Patrik; Svensson, Henry

    2014-12-01

    A method of breast reconstruction is based on the Deep Inferior Epigastric Perforator (DIEP) technique. Skin and fat are transplanted from the abdomen to the chest; blood vessels are reconnected through microsurgery. Nerves are, however, left unconnected. This study aims to evaluate the blood flow and reinnervation of blood vessels and skin in breasts reconstructed by DIEP flaps without neural repair. In all, DIEP flaps of 10 patients were tested at an average of 16.3 months postoperatively. Blood flow was assessed by PeriScan PIM II System, both before and after indirect heating. Tactile perception threshold was assessed by Semmes-Weinstein monofilament and thermal sensibility by SENSELab MSA Thermotest. The patients' contralateral breasts were used as controls. The blood flow of the flaps was statistically significantly lower than in the control breasts, both before and after indirect heating. The change in blood flow after indirect heating did, however, not significantly differ when comparing the breasts. All flaps regained deep pressure sensibility in all four quadrants. Five patients regained even better sensibility in one of their quadrants. Seven patients regained perception of cold stimuli, five perceived warmth. This study has shown that skin blood flow regulation is present in DIEP flaps 1 year after reconstruction. Blood flow dynamics are very similar to those in the normal breast. There is also a recovery of tactile and thermal sensibility, but this study has not shown any clear parallels between recovery blood flow, tactile sensibility and thermal sensibility.

  3. Measurement of temperature decrease caused by blood flow in focused ultrasound irradiation by thermal imaging method

    Science.gov (United States)

    Tsuchiya, Takenobu; Hatano, Yuichi; Mori, Yashunori; Shen, Rakushin; Endoh, Nobuyuki

    2016-07-01

    In this study, to estimate the local temperature changes caused by a thick blood vessel, the temperature distribution in a tissue phantom with a thick blood vessel during focused ultrasound irradiation was measured by a thermal imaging method. The blood flow rate in the simulated blood vessel was varied and the relationship between flow rate and temperature decrease was examined. The phantom using the thermal imaging method is divided into two parts, and the increases in temperature distribution as a function of blood flow rate are measured using a thermocamera under constant ultrasound irradiation. The irradiation conditions of ultrasound waves were a central frequency of 1 MHz, a wave number length of 200 cycles, and a duty ratio of 0.2. The irradiation duration was 5 min, and the ultrasound intensity I SPTA was 36 W/cm2. The amount of temperature decrease caused by the cooling effect of blood flow increased with the blood flow rate and it became constant at a certain threshold of blood flow rate. The threshold of blood flow rate is about 250 ml/min.

  4. Insulin partially reverses deficits in peripheral nerve blood flow and conduction in experimental diabetes

    NARCIS (Netherlands)

    Gispen, W.H.; Biessels, G.J.; Stevens, E.J.; Mahmood, S.J.; Tomlinson, D.R.

    1996-01-01

    Decreased nerve blood flow may be a pathogenetic factor in diabetic neuropathy. Previously it was shown that insulin treatment, commenced at the onset of streptozotocin-diabetes, prevents the development of a nerve blood flow deficit in the diabetic rat. The present study sought to determine the eff

  5. Blood flow response to electrically induced twitch and tetanic lower-limb muscle contractions.

    NARCIS (Netherlands)

    Janssen, T.W.; Hopman, M.T.E.

    2003-01-01

    OBJECTIVES: To compare the effect of electric stimulation (ES)-induced twitch with tetanic leg muscle contractions on blood flow responses and to assess blood flow responses in the contralateral inactive leg. DESIGN: Intervention with within-subject comparisons. SETTING: University research laborato

  6. Effect of intracapsular hyperpressure on femoral head blood flow. Laser Doppler flowmetry in dogs.

    Science.gov (United States)

    Vegter, J; Klopper, P J

    1991-08-01

    Intracapsular hyperpressure in the hip joint of dogs affected femoral head blood flow, especially in the juvenile animals. Graphic recording of the laser Doppler signal curve using rapid sampling time demonstrated venous hip joint tamponade in both juvenile and adult dogs. Laser Doppler flowmetry seems to be a sensitive and reproducible method to demonstrate femoral-head blood-flow changes.

  7. Effects of inspiratory resistance, inhaled beta-agonists and histamine on canine tracheal blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, W.T.; Baile, E.M.; Brancatisano, A.; Pare, P.D.; Engel, L.A. (Dept. of Respiratory Medicine, Westmead Hospital, Westmead, NSW (Australia))

    1992-01-01

    Tracheobronchial blood flow is potentially important in asthma as it could either influence the clearance of mediators form the airways, thus affecting the duration and severity of bronchoispasm, or enhance oedema formation with a resultant increase in airflow obstruction. In anaesthetized dogs, spontaneously breathing via a tracheostomy, we investigated the effects of three interventions which are relevant to acute asthma attacks and could potentially influence blood flow and its distribution to the mucosa and remaining tissues of the trachea: (1) increased negative intrathoracic pressure swings (-25[+-]1 cmH[sub 2]O) induced by an inspiratory resistance; (2) variable inhaled doses of a beta-adrenoceptor-agonist (terbutaline); and (3) aerosolized histamine sufficient to produce a threefold increase in pulmonary resistance. Microspheres labelled with different radioisotopes were used to measure blood flow. Resistive breathing did not influence tracheobronchial blood flow. Following a large dose of terbutaline, mucosal blood flow (Qmb) increased by 50%. After inhaled histamine, Qmb reached 265% of the baseline value. We conclude that, whereas increased negative pressure swings do not influence tracheobronchial blood flow or its distribution, inhalation of aerosolized terbutaline, corresponding to a conventionally nebulized dose, increases mucosal blood flow. Our results also confirm that inhaled histamine, in a dose sufficient to produce moderate bronchoconstriction, increases tracheal mucosal blood flow in the area of deposition. (au).

  8. Phase-Contrast Magnetic Resonance Angiography Measurements of Global Cerebral Blood Flow in the Neonate

    NARCIS (Netherlands)

    Benders, Manon J. N. L.; Hendrikse, Jeroen; de Vries, Linda S.; van Bel, Frank; Groenendaal, Floris

    2011-01-01

    Cerebral blood flow (CBF) alterations are important in pathogenesis of neonatal ischemic/hemorrhagic brain damage. In clinical practice, estimation of neonatal CBF is mostly based on Doppler-measured blood flow velocities in major intracranial arteries. Using phase-contrast magnetic resonance angiog

  9. Cerebral oxygen extraction, oxygen consumption, and regional cerebral blood flow during the aura phase of migraine

    DEFF Research Database (Denmark)

    Friberg, L; Olesen, Jes; Lassen, N A

    1994-01-01

    The aura phase of migraine is associated with focal blood flow changes, but it has been largely unknown whether these changes are correlated to changes in the cerebral metabolism.......The aura phase of migraine is associated with focal blood flow changes, but it has been largely unknown whether these changes are correlated to changes in the cerebral metabolism....

  10. Leg blood flow measurements using venous occlusion plethysmography during head-up tilt.

    NARCIS (Netherlands)

    Kooijman, M.; Poelkens, F.; Rongen, G.A.; Smits, P.; Hopman, M.T.E.

    2007-01-01

    We tested whether venous occlusion plethysmography (VOP) is an appropriate method to measure calf blood flow (CBF) during head-up tilt (HUT). CBF measured with VOP was compared with superficial femoral artery blood flow as measured by Doppler ultrasound during incremental tilt angles. Measurements o

  11. Dynamic noise correction for IVUS quantitative volume blood flow: methods and numerical validation.

    NARCIS (Netherlands)

    Lupotti, F.A.; Korte, C.L. de; Mastik, F.; Steen, A.F.W. van der

    2002-01-01

    In recent years, a new method to measure transverse blood flow based on the decorrelation of the radio-frequency (RF) signals, has been developed. Transverse blood flow estimation may be influenced by noise. In this paper, we investigated a new correlation-based method for noise correction. The deco

  12. Should blood flow during cardiopulmonary bypass be individualized more than to body surface area?

    DEFF Research Database (Denmark)

    Thomassen, Sisse Anette; Larsson, A; Andreasen, Jan Jesper;

    Blood flow during cardiopulmonary bypass (CPB) is calculated on body surface area (BSA). Increasing comorbidity, age and weight of today's cardiac patients question this calculation as it may not reflect individual metabolic requirement. The hypothesis was that a measured cardiac index (CI) prior...... not improve cerebral and systemic oxygenation compared to a blood flow based on BSA....

  13. Regional blood flow during exercise in humans measured by near-infrared spectroscopy and indocyanine green

    DEFF Research Database (Denmark)

    Boushel, R; Langberg, Henning; Olesen, J;

    2000-01-01

    Using near-infrared spectroscopy (NIRS) and the tracer indocyanine green (ICG), we quantified blood flow in calf muscle and around the Achilles tendon during plantar flexion (1-9 W). For comparison, blood flow in calf muscle was determined by dye dilution in combination with magnetic resonance im...

  14. Effect of spinal sympathetic blockade upon postural changes of blood flow in human peripheral tissues

    DEFF Research Database (Denmark)

    Skagen, K; Haxholdt, O; Henriksen, O

    1982-01-01

    local nervous blockade was induced by Lidocaine in 133Xe labelled subcutaneous tissue on one side. During epidural blockade and tilt blood flow increased by 12% whereas blood flow decreased by 30% on the control side. Thus epidural blockade had no influence on the vasoconstrictor response...

  15. Adrenergically stimulated blood flow in brown adipose tissue is not dependent on thermogenesis.

    Science.gov (United States)

    Abreu-Vieira, Gustavo; Hagberg, Carolina E; Spalding, Kirsty L; Cannon, Barbara; Nedergaard, Jan

    2015-05-01

    Brown adipose tissue (BAT) thermogenesis relies on blood flow to be supplied with nutrients and oxygen and for the distribution of the generated heat to the rest of the body. Therefore, it is fundamental to understand the mechanisms by which blood flow is regulated and its relation to thermogenesis. Here, we present high-resolution laser-Doppler imaging (HR-LDR) as a novel method for noninvasive in vivo measurement of BAT blood flow in mice. Using HR-LDR, we found that norepinephrine stimulation increases BAT blood flow in a dose-dependent manner and that this response is profoundly modulated by environmental temperature acclimation. Surprisingly, we found that mice lacking uncoupling protein 1 (UCP1) have fully preserved BAT blood flow response to norepinephrine despite failing to perform thermogenesis. BAT blood flow was not directly correlated to systemic glycemia, but glucose injections could transiently increase tissue perfusion. Inguinal white adipose tissue, also known as a brite/beige adipose tissue, was also sensitive to cold acclimation and similarly increased blood flow in response to norepinephrine. In conclusion, using a novel noninvasive method to detect BAT perfusion, we demonstrate that adrenergically stimulated BAT blood flow is qualitatively and quantitatively fully independent of thermogenesis, and therefore, it is not a reliable parameter for the estimation of BAT activation and heat generation.

  16. Changes in subcutaneous blood flow during locally applied negative pressure to the skin

    DEFF Research Database (Denmark)

    Skagen, K; Henriksen, O

    1983-01-01

    The effect of locally applied subatmospheric pressure on subcutaneous blood flow was studied in 12 healthy subjects. Blood flow was measured on the forearm by the local 133Xe wash-out technique. Air suction between 10 mmHg and 250 mmHg was applied to the skin. Subatmospheric pressure of 20 mmHg c...

  17. Quantitative evaluation of myocardial function by a volume-normalized map generated from relative blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Fukami, Tadanori [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Sato, Hidenori [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Wu, Jin [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Lwin, Thet-Thet- [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Yuasa, Tetsuya [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Kawano, Satoru [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Iida, Keiji [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Akatsuka, Takao [Department of Bio-system Engineering, Faculty of Engineering, Yamagata University, Yonezawa, Yamagata 992-8510 (Japan); Hontani, Hidekata [Department of Computer Science and Engineering, Nagoya Institute of Technology, Aichi 466-8555 (Japan); Takeda, Tohoru [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Tamura, Masao [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan); Yokota, Hiroshi [Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki 305-8575 (Japan)

    2007-07-21

    Our study aimed to quantitatively evaluate blood flow in the left ventricle (LV) of apical hypertrophic cardiomyopathy (APH) by combining wall thickness obtained from cardiac magnetic resonance imaging (MRI) and myocardial perfusion from single-photon emission computed tomography (SPECT). In this study, we considered paired MRI and myocardial perfusion SPECT from ten patients with APH and ten normals. Myocardial walls were detected using a level set method, and blood flow per unit myocardial volume was calculated using 3D surface-based registration between the MRI and SPECT images. We defined relative blood flow based on the maximum in the whole myocardial region. Accuracies of wall detection and registration were around 2.50 mm and 2.95 mm, respectively. We finally created a bull's-eye map to evaluate wall thickness, blood flow (cardiac perfusion) and blood flow per unit myocardial volume. In patients with APH, their wall thicknesses were over 10 mm. Decreased blood flow per unit myocardial volume was detected in the cardiac apex by calculation using wall thickness from MRI and blood flow from SPECT. The relative unit blood flow of the APH group was 1/7 times that of the normals in the apex. This normalization by myocardial volume distinguishes cases of APH whose SPECT images resemble the distributions of normal cases.

  18. A disturbed macrocirculatory supply as a determinant for a reduced sciatic nerve blood flow in diabetic rats

    NARCIS (Netherlands)

    Gispen, W.H.; Buren, Th. van; Kappelle, A.C.; Kasbergen, C.M.; Wildt, D.J. de

    1996-01-01

    The aim of this study was to evaluate macrocirculatory disturbances in relation to the reduced sciatic nerve blood flow seen in diabetic rats. Therefore, both femoral blood flow, the macrocirculatory arterial blood supply to the sciatic nerve, and the microcirculatory neuronal blood flow were measur

  19. Fetal liver blood flow distribution: role in human developmental strategy to prioritize fat deposition versus brain development.

    Directory of Open Access Journals (Sweden)

    Keith M Godfrey

    Full Text Available Among primates, human neonates have the largest brains but also the highest proportion of body fat. If placental nutrient supply is limited, the fetus faces a dilemma: should resources be allocated to brain growth, or to fat deposition for use as a potential postnatal energy reserve? We hypothesised that resolving this dilemma operates at the level of umbilical blood distribution entering the fetal liver. In 381 uncomplicated pregnancies in third trimester, we measured blood flow perfusing the fetal liver, or bypassing it via the ductus venosus to supply the brain and heart using ultrasound techniques. Across the range of fetal growth and independent of the mother's adiposity and parity, greater liver blood flow was associated with greater offspring fat mass measured by dual-energy X-ray absorptiometry, both in the infant at birth (r = 0.43, P<0.001 and at age 4 years (r = 0.16, P = 0.02. In contrast, smaller placentas less able to meet fetal demand for essential nutrients were associated with a brain-sparing flow pattern (r = 0.17, p = 0.02. This flow pattern was also associated with a higher degree of shunting through ductus venosus (P = 0.04. We propose that humans evolved a developmental strategy to prioritize nutrient allocation for prenatal fat deposition when the supply of conditionally essential nutrients requiring hepatic inter-conversion is limited, switching resource allocation to favour the brain if the supply of essential nutrients is limited. Facilitated placental transfer mechanisms for glucose and other nutrients evolved in environments less affluent than those now prevalent in developed populations, and we propose that in circumstances of maternal adiposity and nutrient excess these mechanisms now also lead to prenatal fat deposition. Prenatal developmental influences play important roles in the human propensity to deposit fat.

  20. Magnetic field effect on blood flow of Casson fluid in axisymmetric cylindrical tube: A fractional model

    Science.gov (United States)

    Ali, Farhad; Sheikh, Nadeem Ahmad; Khan, Ilyas; Saqib, Muhammad

    2017-02-01

    The effects of magnetohydrodynamics on the blood flow when blood is represented as a Casson fluid, along with magnetic particles in a horizontal cylinder is studied. The flow is due to an oscillating pressure gradient. The Laplace and finite Hankel transforms are used to obtain the closed form solutions of the fractional partial differential equations. Effects of various parameters on the flow of both blood and magnetic particles are shown graphically. The analysis shows that, the model with fractional order derivatives bring a remarkable changes as compared to the ordinary model. The study highlights that applied magnetic field reduces the velocities of both the blood and magnetic particles.

  1. Numerical simulation of the non-Newtonian blood flow through a mechanical aortic valve. Non-Newtonian blood flow in the aortic root

    Science.gov (United States)

    De Vita, F.; de Tullio, M. D.; Verzicco, R.

    2016-04-01

    This work focuses on the comparison between Newtonian and non-Newtonian blood flows through a bileaflet mechanical heart valve in the aortic root. The blood, in fact, is a concentrated suspension of cells, mainly red blood cells, in a Newtonian matrix, the plasma, and consequently its overall behavior is that of a non-Newtonian fluid owing to the action of the cells' membrane on the fluid part. The common practice, however, assumes the blood in large vessels as a Newtonian fluid since the shear rate is generally high and the effective viscosity becomes independent of the former. In this paper, we show that this is not always the case even in the aorta, the largest artery of the systemic circulation, owing to the pulsatile and transitional nature of the flow. Unexpectedly, for most of the pulsating cycle and in a large part of the fluid volume, the shear rate is smaller than the threshold level for the blood to display a constant effective viscosity and its shear thinning character might affect the system dynamics. A direct inspection of the various flow features has shown that the valve dynamics, the transvalvular pressure drop and the large-scale features of the flow are very similar for the Newtonian and non-Newtonian fluid models. On the other hand, the mechanical damage of the red blood cells (hemolysis), induced by the altered stress values in the flow, is larger for the non-Newtonian fluid model than for the Newtonian one.

  2. Cerebral blood flow, oxygen and glucose metabolism with PET in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Makoto; Ichiya, Yuici; Kuwabara, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine) (and others)

    1989-11-01

    Cerebral blood flow, cerebral oxygen metabolic rate and cerebral glucose metabolic rate were measured with positron emission tomography (PET) in four patients with progressive supranuclear palsy (PSP). Decreased blood flow and hypometabolism of oxygen and glucose were found in both subcortical and cortical regions, particularly in the striatum including the head of the caudate nucleus and the frontal cortex. The coupling between blood flow and metabolism was preserved even in the regions which showed decreased blood flow and hypometabolism. These findings indicated the hypofunction, as revealed by decreased blood flow and hypometablolism on PET, both in the striatum and the frontal cortex, and which may underlie the pathophysiological mechanism of motor and mental disturbance in PSP. (author).

  3. Loss of autoregulation of blood flow in subcutaneous tissue in juvenile diabetes

    DEFF Research Database (Denmark)

    Henriksen, O; Kastrup, J; Parving, H H;

    1984-01-01

    and retinopathy. The blood flow remained constant in all normal subjects, when the arterial perfusion pressure was varied between 70 and 150 mm Hg. All diabetics had impaired or reduced autoregulation of the subcutaneous blood flow. The blood flow increased and decreased almost linearly with the changes...... in arterial perfusion pressure. The mechanism underlying the defect autoregulation of blood flow in diabetics is uncertain; possibilities include structural changes of the arterioles and/or alterations of local metabolic factors.......The autoregulation of blood flow in subcutaneous tissue was investigated at the level of the lateral malleolus by the local 133Xenon washout technique. We have investigated eight long-term insulin-dependent diabetics and seven healthy controls. All diabetics had moderate diabetic nephropathy...

  4. Peculiarities of Blood Flow Changes in Venae Cavae during Experimental Pulmonary Embolism.

    Science.gov (United States)

    Evlakhov, V I; Poyassov, I Z; Shaidakov, E V

    2016-10-01

    The model of acute pulmonary embolism in rabbits demonstrated reduced pulmonary blood flow, cardiac output, left atrial pressure, and blood flow in venae cavae against the background of elevated left pulmonary artery pressure and increased pulmonary vascular resistance. Simultaneously, the blood flow in the superior vena cava decreased to a lesser extent than that in the inferior vena cava, which was a characteristic feature of the model of pulmonary pathology. In contrast, when histamine was infused into the left jugular vein to equally elevate pressure in pulmonary artery as in the above model, the blood flow in the superior vena cava decreased to a greater extent than that in inferior vena cava. During stenosis of inferior vena cava that decreased the cardiac output to the level observed during modeled pulmonary embolism, the blood flows in both venae cavae dropped equally.

  5. Mechanisms of temporal variation in single-nephron blood flow in rats

    DEFF Research Database (Denmark)

    Yip, K P; Holstein-Rathlou, N H; Marsh, D J

    1993-01-01

    Modified laser-Doppler velocimetry was used to determine the number of different mechanisms regulating single-nephron blood flow. Two oscillations were identified in star vessel blood flow, one at 20-50 mHz and another at 100-200 mHz. Tubuloglomerular feedback (TGF) mediates the slower oscillation......, and the faster one is probably myogenic in origin. Acute hypertension increased autospectral power in the 20-50 mHz and 100-200 mHz frequency bands to 282 +/- 50 and 248 +/- 64%, respectively, of control even though mean single-nephron blood flow was autoregulated. Mean blood flow increased 24.6 +/- 6.1% when...... components in efferent arteriole blood flow....

  6. Micro-PIV quantification of capillary blood flow redistribution caused by laser-assisted vascular occlusion

    Science.gov (United States)

    Kurochkin, Maxim A.; Stiukhina, Elena S.; Fedosov, Ivan V.; Postnov, Dmitry E.; Tuchin, Valery V.

    2016-04-01

    We propose μPIV-based technique for quantitative assessment of blood flow redistribution in microcirculatory networks. Our approach is based on per-segment averaging of measured quantities so we can avoid most of problems that are typical for point-wise measurements. The key point of our technique is the digital processing algorithms of recorded data that include: capillary network axial line construction; interrogation regions centering; blood flow velocity local estimate using PIV approach; blood flow velocity calculation by means of averaging over entire vessel segment; the calculation of blood volume flow rate map. We illustrate the application of developed technique with in vivo measurements and blood flow velocity map reconstruction for chorioallantoic membrane (CAM) of chicken embryo, in which the local vascular occlusion was produced using continuous wave laser light irradiation..

  7. Elevated Skin Blood Flow Influences Near Infrared Spectroscopy Measurements During Supine Rest

    Science.gov (United States)

    Lee, Stuart M. C.; Clarke, Mark S. F.

    2004-01-01

    Near infrared spectroscopy is a non-invasive technique that allows determination of tissue oxygenation/blood flow based on spectrophotometric quantitation of oxy- and deoxyhemoglobin present within a tissue. This technique has gained acceptance as a means of detecting and quantifying changes in tissue blood flow due to physiological perturbation, such as that which is elicited in skeletal muscle during exercise. Since the NIRS technique requires light to penetrate the skin and subcutaneous fat in order to reach the muscle of interest, changes in skin blood flow may alter the NIRS signal in a fashion unrelated to blood flow in the muscle of interest. The aim of this study was to determine the contribution of skin blood flow to the NIRS signal obtained from resting vastus lateralis muscle of the thigh.

  8. Blood flow and epithelial thickness in different regions of feline oral mucosa and skin.

    Science.gov (United States)

    Johnson, G K; Squier, C A; Johnson, W T; Todd, G L

    1987-07-01

    The relationship between epithelial thickness and blood flow was examined in 6 mucosal and 3 skin regions of the cat. Blood flow to these tissues was determined using the radiolabelled microsphere method. From histologic sections the proportion of the tissue biopsy occupied by epithelium and the average epithelial thickness were calculated. The oral tissues had a significantly higher blood flow than the skin regions (p less than 0.05). In terms of epithelial thickness, the tissues could be divided into 4 groups (p less than 0.05). These were: a) palate; b) gingival regions and dorsum of the tongue; c) lip and buccal mucosa; d) all skin regions. When epithelial thickness was related to blood flow there was a significant positive correlation (p less than 0.005) indicating that a thicker epithelium is associated with a higher blood flow. This finding may reflect the greater metabolic demands of the thicker epithelia.

  9. Transcranial Doppler-determined change in posterior cerebral artery blood flow velocity does not reflect vertebral artery blood flow during exercise.

    Science.gov (United States)

    Washio, Takuro; Sasaki, Hiroyuki; Ogoh, Shigehiko

    2017-02-10

    We examined whether a change in posterior cerebral artery flow velocity (PCAv) reflected the posterior cerebral blood flow, in healthy subjects, during both static and dynamic exercise. PCAv and vertebral artery (VA) blood flow, as an index of posterior blood flow, were continuously measured during an exercise trial, using transcranial Doppler (TCD) ultrasonography and Doppler ultrasound, respectively. Static handgrip exercise significantly increased both PCAv and VA blood flow. Increasing intensity of dynamic exercise further increased VA blood flow from moderate exercise, while PCAv decreased to almost resting level. During both static and dynamic exercise, the PCA cerebrovascular conductance (CVC) index significantly decreased from rest (static and high intensity dynamic exercise; -11.5 ± 12.2% and -18.0 ± 16.8%; mean ± SD, respectively), despite no change in the CVC of VA. These results indicate that vasoconstriction occurred at PCA but not VA during exercise-induced hypertension. This discrepancy in vascular response to exercise between PCA and VA may be due to different cerebral arterial characteristics. Therefore, to determine the effect of exercise on posterior cerebral circulation, at least, we need to consider carefully which cerebral artery to measure, regardless of exercise mode.

  10. Modelling of the Blood Coagulation Cascade in an In Vitro Flow System

    DEFF Research Database (Denmark)

    Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.;

    2010-01-01

    We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking into...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade.......We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...

  11. Semiquantitative imaging measurement of baseline and vasomodulated normal prostatic blood flow using sildenafil

    Science.gov (United States)

    Haaga, JR; Exner, A; Fei, B; Seftel, AD

    2013-01-01

    The physiologic variability of blood flow to the prostate has not been studied until this time. We report the vasoactive effects of sildenafil and phenylephrine on blood flow of the normal prostate. Sildenafil increases prostate blood flow by approximately 75% and phenylephrine reduces the flow incrementally. Administration of these drugs with dynamic contrast-enhanced magnetic resonance imaging may improve the diagnosis of cancerous tissue because according to the literature, tumor angiogenic vessels lack the vasoactive physiologic response of the normal tissue. PMID:16728965

  12. Renal cortical and medullary blood flow responses to altered NO-availability in humans

    DEFF Research Database (Denmark)

    Damkjaer, Mads; Vafaee, Manoucher; Møller, Michael Lehd;

    2010-01-01

    of one voxel were eliminated stepwise from the external surface of the VOI ('voxel peeling'), and the blood flow subsequently determined in each new, reduced VOI. Blood flow in the shrinking volumes of interest (VOIs) decreased as the number of cycles of voxel peeling increased. After 4-5 cycles, blood...... flow was not reduced further by additional voxel peeling. This volume-insensitive flow was measured to be 2.30 ±0.17 ml·(g·min)(-1) during the control period; it increased during infusion of glyceryl nitrate to 2.97 ±0.18 ml·(g·min)(-1) (p...

  13. Topical negative pressure effects on coronary blood flow in a sternal wound model

    DEFF Research Database (Denmark)

    Lindstedt, Sandra; Malmsjö, Malin; Gesslein, Bodil;

    2008-01-01

    patients with topical negative pressure (TNP)-treated mediastinitis and CABG patients without mediastinitis. The present study was designed to elucidate if TNP, applied over the myocardium, resulted in an increase of the total amount of coronary blood flow. Six pigs underwent median sternotomy....... The coronary blood flow was measured, before and after the application of TNP (-50 mmHg), using coronary electromagnetic flow meter probes. Analyses were performed before left anterior descending artery (LAD) occlusion (normal myocardium) and after 20 minutes of LAD occlusion (ischaemic myocardium). Normal...... coronary blood flow in both normal and ischaemic myocardium....

  14. Trace Elements (Pb, Zn, Cu in Blood of Mute Swan (Cygnus olor from the Isonzo River Nature Reserve (Italy

    Directory of Open Access Journals (Sweden)

    G Isani*, M Cipone, G Andreani, E Carpenè, E Ferlizza, K Kravos1 and F Perco1

    2013-11-01

    Full Text Available Lead concentrations in blood of 45 specimens of mute swan from the molting area of the Isonzo River Mouth Nature Reserve (Italy were determined in two consecutive years (2006-2007, some birds were neck ringed to identify their homing behavior. The second sampling included whole body X-ray radiography and Cu and Zn plasma analyses to investigate the health impact of putative Pb exposure. X-ray images of all investigated specimens did not show any radiopacity due to the ingestion of metal bodies. Lead levels (0.08-0.44 g/ml were in the range of those reported for swans living in unpolluted or slightly polluted environments and excluded acute intoxication, as confirmed by clinical investigation. Zinc concentrations ranged between 2.93 and 7.59 g/ml and were one order of magnitude higher than Cu concentrations (0.21-0.42 g/ml. The negative correlation between Pb and Zn concentrations could be indicative of adverse health effects caused by chronic lead exposure. To our knowledge this is the first study reporting Pb, Zn and Cu blood levels, X-ray radiographies and data on the origin of swan populations.

  15. Experimental determination of blood permittivity and conductivity in simple shear flow.

    Science.gov (United States)

    Balan, Corneliu; Balut, Corina; Gheorghe, Liana; Gheorghe, Cristian; Gheorghiu, Eugen; Ursu, George

    2004-01-01

    The paper is concerned with the determination of blood permittivity and conductivity in Poiseuille and Couette simple shear flows. The experimental procedure, based on dielectric spectroscopy, evidences the sensitivity of blood electric properties to the applied frequency and local shear rate magnitude. The method evidences the possibility to correlate (for well-defined flow geometry) magnitude of shear rate, and consequently the shear stress level, with spectra permittivity of blood.

  16. Cerebral blood flow in small vessel disease: A systematic review and meta-analysis.

    Science.gov (United States)

    Shi, Yulu; Thrippleton, Michael J; Makin, Stephen D; Marshall, Ian; Geerlings, Mirjam I; de Craen, Anton Jm; van Buchem, Mark A; Wardlaw, Joanna M

    2016-10-01

    White matter hyperintensities are frequent on neuroimaging of older people and are a key feature of cerebral small vessel disease. They are commonly attributed to chronic hypoperfusion, although whether low cerebral blood flow is cause or effect is unclear. We systematically reviewed studies that assessed cerebral blood flow in small vessel disease patients, performed meta-analysis and sensitivity analysis of potential confounders. Thirty-eight studies (n = 4006) met the inclusion criteria, including four longitudinal and 34 cross-sectional studies. Most cerebral blood flow data were from grey matter. Twenty-four cross-sectional studies (n = 1161) were meta-analysed, showing that cerebral blood flow was lower in subjects with more white matter hyperintensity, globally and in most grey and white matter regions (e.g. mean global cerebral blood flow: standardised mean difference-0.71, 95% CI -1.12, -0.30). These cerebral blood flow differences were attenuated by excluding studies in dementia or that lacked age-matching. Four longitudinal studies (n = 1079) gave differing results, e.g., more baseline white matter hyperintensity predated falling cerebral blood flow (3.9 years, n = 575); cerebral blood flow was low in regions that developed white matter hyperintensity (1.5 years, n = 40). Cerebral blood flow is lower in subjects with more white matter hyperintensity cross-sectionally, but evidence for falling cerebral blood flow predating increasing white matter hyperintensity is conflicting. Future studies should be longitudinal, obtain more white matter data, use better age-correction and stratify by clinical diagnosis.

  17. Assessment of changes in liver blood flow after food intake—comparison of ICG clearance and echo-Doppler

    OpenAIRE

    Burggraaf, J; Schoemaker, H C; Cohen, A F

    1996-01-01

    Echo-Doppler measurements of portal venous blood flow in intrahepatic branches and indocyanine green (ICG) clearance after continuous i.v. infusion as measure for liver blood flow were compared to evaluate the increase in splanchnic blood flow after food intake. It was shown that both methods assessed the changes in flow in a similar manner. Changes in blood flow in intrahepatic portal vein branches measured with echo-Doppler adequately predicted the change in ICG concentrations. Hence, echo-...

  18. Computational modelling of blood-flow-induced changes in blood electrical conductivity and its contribution to the impedance cardiogram.

    Science.gov (United States)

    Trakic, A; Akhand, M; Wang, H; Mason, D; Liu, F; Wilson, S; Crozier, S

    2010-01-01

    Studies have shown that blood-flow-induced change in electrical conductivity is of equal importance in assessment of the impedance cardiogram (ICG) as are volumetric changes attributed to the motion of heart, lungs and blood vessels. To better understand the sole effect of time-varying blood conductivity on the spatiotemporal distribution of trans-thoracic electric fields (i.e. ICG), this paper presents a segmented high-resolution (1 mm(3)) thoracic cardiovascular system, in which the time-varying pressures, flows and electrical conductivities of blood in different vessels are evaluated using a set of coupled nonlinear differential equations, red blood cell orientation and cardiac cycle functions. Electric field and voltage simulations are performed using two and four electrode configurations delivering a small alternating electric current to an anatomically realistic and electrically accurate model of modelled human torso. The simulations provide a three-dimensional electric field distribution and show that the time-varying blood conductivity alters the voltage potential difference between the electrodes by a maximum of 0.28% for a cardiac output of about 5 L min(-1). As part of a larger study, it is hoped that this initial model will be useful in providing improved insights into blood-flow-related spatiotemporal electric field variations and assist in the optimal placement of electrodes in impedance cardiography experiments.

  19. EFFECTS OF VASCULAR ZERO-STRESS STATE ON PULSATILE BLOOD FLOW

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    In this paper, blood flow in artery was treated as the flow under equilibrium state (the steady flow under mean pressure) combined with the periodically small pulsatile flow. Based on vascular zero-stress state[1], the pulsatile strains according to the radial and axial displacements of blood vessel were obtained. With the use of Hooke’s law, the pulsatile strains and the corresponding Cauchy stresses were connected, so the corresponding wall motion equations could be established here. By solving the linearized Navier-Stokes equations, the analytic expressions of the blood flow velocities and the vascular displacements could be obtained, and the influence of the circumferential and axial stretch ratio on pulsatile blood flow and vascular motion was discussed in details.

  20. Facial skin blood flow responses during exposures to emotionally charged movies.

    Science.gov (United States)

    Matsukawa, Kanji; Endo, Kana; Ishii, Kei; Ito, Momoka; Liang, Nan

    2017-01-21

    The changes in regional facial skin blood flow and vascular conductance have been assessed for the first time with noninvasive two-dimensional laser speckle flowmetry during audiovisually elicited emotional challenges for 2 min (comedy, landscape, and horror movie) in 12 subjects. Limb skin blood flow and vascular conductance and systemic cardiovascular variables were simultaneously measured. The extents of pleasantness and consciousness for each emotional stimulus were estimated by the subjective rating from -5 (the most unpleasant; the most unconscious) to +5 (the most pleasant; the most conscious). Facial skin blood flow and vascular conductance, especially in the lips, decreased during viewing of comedy and horror movies, whereas they did not change during viewing of a landscape movie. The decreases in facial skin blood flow and vascular conductance were the greatest with the comedy movie. The changes in lip, cheek, and chin skin blood flow negatively correlated (P blood flow and vascular conductance and systemic hemodynamics correlated with the subjective ratings. The mental arithmetic task did not alter facial and limb skin blood flows, although the task influenced systemic cardiovascular variables. These findings suggest that the more emotional status becomes pleasant or conscious, the more neurally mediated vasoconstriction may occur in facial skin blood vessels.

  1. Computational Fluid Dynamics Analysis of Pulsatile Blood Flow Behavior in Modelled Stenosed Vessels with Different Severities

    Directory of Open Access Journals (Sweden)

    Mohsen Mehrabi

    2012-01-01

    Full Text Available This study focuses on the behavior of blood flow in the stenosed vessels. Blood is modelled as an incompressible non-Newtonian fluid which is based on the power law viscosity model. A numerical technique based on the finite difference method is developed to simulate the blood flow taking into account the transient periodic behaviour of the blood flow in cardiac cycles. Also, pulsatile blood flow in the stenosed vessel is based on the Womersley model, and fluid flow in the lumen region is governed by the continuity equation and the Navier-Stokes equations. In this study, the stenosis shape is cosine by using Tu and Devil model. Comparing the results obtained from three stenosed vessels with 30%, 50%, and 75% area severity, we find that higher percent-area severity of stenosis leads to higher extrapressure jumps and higher blood speeds around the stenosis site. Also, we observe that the size of the stenosis in stenosed vessels does influence the blood flow. A little change on the cross-sectional value makes vast change on the blood flow rate. This simulation helps the people working in the field of physiological fluid dynamics as well as the medical practitioners.

  2. HIV and chronic methamphetamine dependence affect cerebral blood flow.

    Science.gov (United States)

    Ances, Beau M; Vaida, Florin; Cherner, Mariana; Yeh, Melinda J; Liang, Christine L; Gardner, Carly; Grant, Igor; Ellis, Ronald J; Buxton, Richard B

    2011-09-01

    Human immunodeficiency virus (HIV) and methamphetamine (METH) dependence are independently associated with neuronal dysfunction. The coupling between cerebral blood flow (CBF) and neuronal activity is the basis of many task-based functional neuroimaging techniques. We examined the interaction between HIV infection and a previous history of METH dependence on CBF within the lenticular nuclei (LN). Twenty-four HIV-/METH-, eight HIV-/METH+, 24 HIV+/METH-, and 15 HIV+/METH+ participants performed a finger tapping paradigm. A multiple regression analysis of covariance assessed associations and two-way interactions between CBF and HIV serostatus and/or previous history of METH dependence. HIV+ individuals had a trend towards a lower baseline CBF (-10%, p = 0.07) and greater CBF changes for the functional task (+32%, p = 0.01) than HIV- subjects. Individuals with a previous history of METH dependence had a lower baseline CBF (-16%, p = 0.007) and greater CBF changes for a functional task (+33%, p = 0.02). However, no interaction existed between HIV serostatus and previous history of METH dependence for either baseline CBF (p = 0.53) or CBF changes for a functional task (p = 0.10). In addition, CBF and volume in the LN were not correlated. A possible additive relationship could exist between HIV infection and a history of METH dependence on CBF with a previous history of METH dependence having a larger contribution. Abnormalities in CBF could serve as a surrogate measure for assessing the chronic effects of HIV and previous METH dependence on brain function.

  3. Regional cerebral blood flow abnormalities in patients with primary hyperparathyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Cermik, Tevfik F. [Hospital of the University of Trakya, Department of Nuclear Medicine, Edirne (Turkey); Trakya Universitesi Hastanesi, Nukleer Tip Anabilim Dali, Gullapoglu Yerleskesi, Edirne (Turkey); Kaya, Meryem; Bedel, Deniz; Berkarda, Sakir; Yigitbasi, Oemer N. [Hospital of the University of Trakya, Department of Nuclear Medicine, Edirne (Turkey); Ugur-Altun, Betuel [Hospital of the University of Trakya, Department of Internal Medicine, Division of Endocrinology, Edirne (Turkey)

    2007-04-15

    We assessed the alterations in regional cerebral blood flow (rCBF) in patients with primary hyperparathyroidism (PHP) before parathyroidectomy by semiquantitative analysis of brain single photon emission computed tomography (SPECT) images. Included in this prospective study were 14 patients (mean age 47.6 {+-} 10.4 years; 3 male, 11 female) and 10 control subjects (mean age 36.0 {+-} 8.5 years, 6 male, 4 female) were SPECT imaging was performed using a dual-headed gamma camera 60-90 min after intravenous administration of 925 MBq Tc-99m HMPAO. The corticocerebellar rCBF ratios were calculated from 52 brain areas and reference lower values (RLVs) were calculated from the rCBF ratios of control subjects. The regional ratios that were below the corresponding RLV were considered abnormal (hypoperfused). Hypoperfusion was shown in 171 out of 728 regions (23%) and there was a significant correlation between serum calcium, PTH levels and the sum of hypoperfused regions in the patient group (R = 0.75 and P = 0.001, and R = 0.75, P = 0.001, respectively). Significantly reduced rCBF were found in the following cortical regions: bilateral cingulate cortex, superior and inferior frontal cortex, anterior temporal cortex, precentral gyrus, postcentral gyrus and parietal cortex, and right posterior temporal cortex. Our results indicate that alterations in rCBF in patients with PHP can be demonstrated with brain SPECT. The correlation between serum calcium, PTH levels and the sum of hypoperfused regions indicates that there may be a strong relationship between rCBF abnormalities and increased levels of serum calcium and PTH. In addition, the degree of rCBF abnormalities could be determined by brain SPECT in PHP patients with or without psychiatric symptoms. (orig.)

  4. Dynamical Modes of Deformed Red Blood Cells and Lipid Vesicles in Flows

    Science.gov (United States)

    Noguchi, H.

    Red blood cells and lipid vesicles exhibit rich behaivor in flows.Their dynamics were studied using a particle-based hydrodynamic simulation method, multi-particle collision dynamics. Rupture of lipid vesicles in simple shear flow was simulated by meshless membrane model. Several shape transitions of lipid vesicles and red blood cells are induced by flows. Transition of a lipid vesicle from budded to prolate shapes with increasing shear rate and ordered alignments of deformed elastic vesicles in high density are presented.

  5. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...... access blood flow measured before and after every procedure. Two methods, catheter-based thermodilution and Doppler ultrasound, were compared to the reference method of ultrasound dilution. Catheter-based thermodilution and Doppler ultrasound were performed during the endovascular procedures while flow...

  6. A theoretical computerized study for the electrical conductivity of arterial pulsatile blood flow by an elastic tube model.

    Science.gov (United States)

    Shen, Hua; Zhu, Yong; Qin, Kai-Rong

    2016-12-01

    The electrical conductivity of pulsatile blood flow in arteries is an important factor for the application of the electrical impedance measurement system in clinical settings. The electrical conductivity of pulsatile blood flow depends not only on blood-flow-induced red blood cell (RBC) orientation and deformation but also on artery wall motion. Numerous studies have investigated the conductivity of pulsatile blood based on a rigid tube model, in which the effects of wall motion on blood conductivity are not considered. In this study, integrating Ling and Atabek's local flow theory and Maxwell-Fricke theory, we develop an elastic tube model to explore the effects of wall motion as well as blood flow velocity on blood conductivity. The simulation results suggest that wall motion, rather than blood flow velocity, is the primary factor that affects the conductivity of flowing blood in arteries.

  7. Continuous-flow microfluidic blood cell sorting for unprocessed whole blood using surface-micromachined microfiltration membranes.

    Science.gov (United States)

    Li, Xiang; Chen, Weiqiang; Liu, Guangyu; Lu, Wei; Fu, Jianping

    2014-07-21

    White blood cells (WBCs) constitute about 0.1% of the blood cells, yet they play a critical role in innate and adaptive immune responses against pathogenic infections, allergic conditions, and malignancies and thus contain rich information about the immune status of the body. Rapid isolation of WBCs directly from whole blood is a prerequisite for any integrated immunoassay platform designed for examining WBC phenotypes and functions; however, such functionality is still challenging for blood-on-a-chip systems, as existing microfluidic cell sorting techniques are inadequate for efficiently processing unprocessed whole blood on chip with concurrent high throughput and cell purity. Herein we report a microfluidic chip for continuous-flow isolation and sorting of WBCs from whole blood with high throughput and separation efficiency. The microfluidic cell sorting chip leveraged the crossflow filtration scheme in conjunction with a surface-micromachined poly(dimethylsiloxane) (PDMS) microfiltration membrane (PMM) with high porosity. With a sample throughput of 1 mL h(-1), the microfluidic cell sorting chip could recover 27.4 ± 4.9% WBCs with a purity of 93.5 ± 0.5%. By virtue of its separation efficiency, ease of sample recovery, and high throughput enabled by its continuous-flow operation, the microfluidic cell sorting chip holds promise as an upstream component for blood sample preparation and analysis in integrated blood-on-a-chip systems.

  8. Tumor blood flow differs between mouse strains: consequences for vasoresponse to photodynamic therapy.

    Directory of Open Access Journals (Sweden)

    Rickson C Mesquita

    Full Text Available Fluctuations in tumor blood flow are common and attributed to factors such as vasomotion or local vascular structure, yet, because vessel structure and physiology are host-derived, animal strain of tumor propagation may further determine blood flow characteristics. In the present report, baseline and stress-altered tumor hemodynamics as a function of murine strain were studied using radiation-induced fibrosacomas (RIF grown in C3H or nude mice. Fluctuations in tumor blood flow during one hour of baseline monitoring or during vascular stress induced by photodynamic therapy (PDT were measured by diffuse correlation spectroscopy. Baseline monitoring revealed fluctuating tumor blood flow highly correlated with heart rate and with similar median periods (i.e., ∼9 and 14 min in C3H and nudes, respectively. However, tumor blood flow in C3H animals was more sensitive to physiologic or stress-induced perturbations. Specifically, PDT-induced vascular insults produced greater decreases in blood flow in the tumors of C3H versus nude mice; similarly, during baseline monitoring, fluctuations in blood flow were more regular and more prevalent within the tumors of C3H mice versus nude mice; finally, the vasoconstrictor L-NNA reduced tumor blood flow in C3H mice but did not affect tumor blood flow in nudes. Underlying differences in vascular structure, such as smaller tumor blood vessels in C3H versus nude animals, may contribute to strain-dependent variation in vascular function. These data thus identify clear effects of mouse strain on tumor hemodynamics with consequences to PDT and potentially other vascular-mediated therapies.

  9. Effect of Hematocrit on Wall Shear Stress for Blood Flow through Tapered Artery

    OpenAIRE

    Singh, A. K.; Singh, D. P.

    2013-01-01

    The purpose of this study to show the effects of Hematocrit (Red blood cells), height of stenosis, porous parameter and velocity of blood on wall shear stress of the flow of blood through tapered artery. The study reveals that wall shear stress reduces for increasing Hematocrit percentage. It is also observed that wall shear stress increases as stenosis height and porous parameter increase whereas it decreases with the increasing values of velocity of blood and slope of tapered artery.

  10. Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI.

    Science.gov (United States)

    Götberg, Matthias; Christiansen, Evald H; Gudmundsdottir, Ingibjörg J; Sandhall, Lennart; Danielewicz, Mikael; Jakobsen, Lars; Olsson, Sven-Erik; Öhagen, Patrik; Olsson, Hans; Omerovic, Elmir; Calais, Fredrik; Lindroos, Pontus; Maeng, Michael; Tödt, Tim; Venetsanos, Dimitrios; James, Stefan K; Kåregren, Amra; Nilsson, Margareta; Carlsson, Jörg; Hauer, Dario; Jensen, Jens; Karlsson, Ann-Charlotte; Panayi, Georgios; Erlinge, David; Fröbert, Ole

    2017-03-18

    Background The instantaneous wave-free ratio (iFR) is an index used to assess the severity of coronary-artery stenosis. The index has been tested against fractional flow reserve (FFR) in small trials, and the two measures have been found to have similar diagnostic accuracy. However, studies of clinical outcomes associated with the use of iFR are lacking. We aimed to evaluate whether iFR is noninferior to FFR with respect to the rate of subsequent major adverse cardiac events. Methods We conducted a multicenter, randomized, controlled, open-label clinical trial using the Swedish Coronary Angiography and Angioplasty Registry for enrollment. A total of 2037 participants with stable angina or an acute coronary syndrome who had an indication for physiologically guided assessment of coronary-artery stenosis were randomly assigned to undergo revascularization guided by either iFR or FFR. The primary end point was the rate of a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization within 12 months after the procedure. Results A primary end-point event occurred in 68 of 1012 patients (6.7%) in the iFR group and in 61 of 1007 (6.1%) in the FFR group (difference in event rates, 0.7 percentage points; 95% confidence interval [CI], -1.5 to 2.8%; P=0.007 for noninferiority; hazard ratio, 1.12; 95% CI, 0.79 to 1.58; P=0.53); the upper limit of the 95% confidence interval for the difference in event rates fell within the prespecified noninferiority margin of 3.2 percentage points. The results were similar among major subgroups. The rates of myocardial infarction, target-lesion revascularization, restenosis, and stent thrombosis did not differ significantly between the two groups. A significantly higher proportion of patients in the FFR group than in the iFR group reported chest discomfort during the procedure. Conclusions Among patients with stable angina or an acute coronary syndrome, an iFR-guided revascularization strategy was

  11. Use of the Instantaneous Wave-free Ratio or Fractional Flow Reserve in PCI.

    Science.gov (United States)

    Davies, Justin E; Sen, Sayan; Dehbi, Hakim-Moulay; Al-Lamee, Rasha; Petraco, Ricardo; Nijjer, Sukhjinder S; Bhindi, Ravinay; Lehman, Sam J; Walters, Darren; Sapontis, James; Janssens, Luc; Vrints, Christiaan J; Khashaba, Ahmed; Laine, Mika; Van Belle, Eric; Krackhardt, Florian; Bojara, Waldemar; Going, Olaf; Härle, Tobias; Indolfi, Ciro; Niccoli, Giampaolo; Ribichini, Flavo; Tanaka, Nobuhiro; Yokoi, Hiroyoshi; Takashima, Hiroaki; Kikuta, Yuetsu; Erglis, Andrejs; Vinhas, Hugo; Canas Silva, Pedro; Baptista, Sérgio B; Alghamdi, Ali; Hellig, Farrel; Koo, Bon-Kwon; Nam, Chang-Wook; Shin, Eun-Seok; Doh, Joon-Hyung; Brugaletta, Salvatore; Alegria-Barrero, Eduardo; Meuwissen, Martijin; Piek, Jan J; van Royen, Niels; Sezer, Murat; Di Mario, Carlo; Gerber, Robert T; Malik, Iqbal S; Sharp, Andrew S P; Talwar, Suneel; Tang, Kare; Samady, Habib; Altman, John; Seto, Arnold H; Singh, Jasvindar; Jeremias, Allen; Matsuo, Hitoshi; Kharbanda, Rajesh K; Patel, Manesh R; Serruys, Patrick; Escaned, Javier

    2017-03-18

    Background Coronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. Methods We randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. Results At 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, -0.2 percentage points; 95% confidence interval [CI], -2.3 to 1.8; Pratio, 0.95; 95% CI, 0.68 to 1.33; P=0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P=0.001). Conclusions Coronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. (Funded by Philips Volcano; DEFINE-FLAIR ClinicalTrials.gov number, NCT02053038 .).

  12. In vivo lateral blood flow velocity measurement using speckle size estimation.

    Science.gov (United States)

    Xu, Tiantian; Hozan, Mohsen; Bashford, Gregory R

    2014-05-01

    In previous studies, we proposed blood measurement using speckle size estimation, which estimates the lateral component of blood flow within a single image frame based on the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is "smeared") if blood flow is in the same direction as the electronically controlled transducer line selection in a 2-D image. In this observational study, the clinical viability of ultrasound blood flow velocity measurement using speckle size estimation was investigated and compared with that of conventional spectral Doppler of carotid artery blood flow data collected from human patients in vivo. Ten patients (six male, four female) were recruited. Right carotid artery blood flow data were collected in an interleaved fashion (alternating Doppler and B-mode A-lines) with an Antares Ultrasound Imaging System and transferred to a PC via the Axius Ultrasound Research Interface. The scanning velocity was 77 cm/s, and a 4-s interval of flow data were collected from each subject to cover three to five complete cardiac cycles. Conventional spectral Doppler data were collected simultaneously to compare with estimates made by speckle size estimation. The results indicate that the peak systolic velocities measured with the two methods are comparable (within ±10%) if the scan velocity is greater than or equal to the flow velocity. When scan velocity is slower than peak systolic velocity, the speckle stretch method asymptotes to the scan velocity. Thus, the speckle stretch method is able to accurately measure pure lateral flow, which conventional Doppler cannot do. In addition, an initial comparison of the speckle size estimation and color Doppler methods with respect to computational complexity and data acquisition time indicated potential time savings in blood flow velocity estimation using speckle size estimation. Further studies are needed for calculation of the speckle stretch method

  13. Effect of blood flow on muscle lactate release studied in perfused rat hindlimb

    DEFF Research Database (Denmark)

    Pilegaard, H; Bangsbo, Jens; Henningsen, P;

    1995-01-01

    The influence of blood flow on muscle lactate and H+ release as well as muscle glyconeogenesis was studied in the perfused rat hindlimb. After 2 min of supramaximal stimulation the perfusate flow rate was 7 (F7), 12 (F12), or 18 (F18) ml/min for 30 min. Perfusate samples were drawn frequently...... between H+ and lactate release was larger (P flow in each of the muscles. The present data suggest that 1) in the range of blood...... flow rates from 0.61 to 0.92 ml.min-1.g-1, lactate and H+ release are independent of the flow rate, whereas at a lower flow rate (0.36 ml.min-1.g-1) release of these substances is decreased; 2) low blood flow influences lactate efflux more than H+ release; and 3) muscle glyconeogenesis from lactate...

  14. [Doppler studies of arterial blood flow in the uterus during labor].

    Science.gov (United States)

    Fendel, H; Fendel, M; Pauen, A; Liedtke, B; Schonlau, H; Warnking, R

    1984-01-01

    By the pulsed doppler method the arterial uterine blood velocity was studied in 19 patients with contractions before and during labour. It is shown, that uterine contractions reduce blood velocity significantly. Normally there is a low resistance in uterine arteries, so that the diastolic flow is nearly as high as the systolic flow. In uterine contractions the vascular resistance increases. Systolic flow is reduced slightly and diastolic flow severely or completely. But a complete zero-flow couldn't observed in any studied uterine contraction.

  15. Effect of Rolling Massage on the Vortex Flow in Blood Vessels with Lattice Boltzmann Simulation

    Science.gov (United States)

    Yi, Hou Hui

    The rolling massage manipulation is a classic Chinese Medical Massage, which is a nature therapy in eliminating many diseases. Here, the effect of the rolling massage on the cavity flows in blood vessel under the rolling manipulation is studied by the lattice Boltzmann simulation. The simulation results show that the vortex flows are fully disturbed by the rolling massage. The flow behavior depends on the rolling velocity and the rolling depth. Rolling massage has a better effect on the flows in the cavity than that of the flows in a planar blood vessel. The result is helpful to understand the mechanism of the massage and develop the rolling techniques.

  16. Carbon dioxide induced changes in cerebral blood flow and flow velocity: Role of cerebrovascular resistance and effective cerebral perfusion pressure

    NARCIS (Netherlands)

    F. Grüne (Frank); S. Kazmaier (Stephan); R.J. Stolker (Robert J.); G.H. Visser (Gerhard Henk); A. Weyland (Andreas)

    2015-01-01

    textabstractIn addition to cerebrovascular resistance (CVR) zero flow pressure (ZFP), effective cerebral perfusion pressure (CPPe) and the resistance area product (RAP) are supplemental determinants of cerebral blood flow (CBF). Until now, the interrelationship of PaCO2 -induced changes in CBF, CVR,

  17. Anxiety and cerebral blood flow during behavioral challenge. Dissociation of central from peripheral and subjective measures

    Energy Technology Data Exchange (ETDEWEB)

    Zohar, J.; Insel, T.R.; Berman, K.F.; Foa, E.B.; Hill, J.L.; Weinberger, D.R.

    1989-06-01

    To investigate the relationship between anxiety and regional cerebral blood flow, we administered behavioral challenges to 10 patients with obsessive-compulsive disorder while measuring regional cerebral blood flow with the xenon 133 inhalation technique. Each patient was studied under three conditions: relaxation, imaginal flooding, and in vivo (actual) exposure to the phobic stimulus. Subjective anxiety, obsessive-compulsive ratings, and autonomic measures (heart rate, blood pressure) increased significantly, but respiratory rate and PCO/sub 2/ did not change across the three conditions. Regional cerebral blood flow increased slightly (in the temporal region) during imaginal flooding, but decreased markedly in several cortical regions during in vivo exposure, when anxiety was highest by subjective and peripheral autonomic measures. These results demonstrate that intense anxiety can be associated with decreased rather than increased cortical perfusion and that ostensibly related states of anxiety (eg, anticipatory and obsessional anxiety) may be associated with opposite effects on regional cerebral blood flow.

  18. Relationship between glycosylated hemoglobin A1c and coronary flow reserve in patients with Type 2 diabetes mellitus.

    Science.gov (United States)

    Huang, Runqing; Abdelmoneim, Sahar S; Nhola, Lara F; Basu, Rita; Basu, Ananda; Mulvagh, Sharon L

    2015-04-01

    Type 2 diabetes mellitus patients are at increased risk for macrovascular and microvascular complications. Both in vivo and in vitro studies of small arteries and arterioles of diabetic subjects demonstrate impaired endothelial function without anatomic lesions. Coronary flow reserve (CFR) is a surrogate marker of coronary microcirculatory endothelial function in diabetic patients without significant stenosis of the associated epicardial coronary artery. Glycosylated hemoglobin A1c is related to likelihood of occurrence of microvascular events. The objective of this article is to report on recent developments in multiple noninvasive techniques to assess CFR and their use in aiding the understanding of the relationship of CFR, glycemic control and cardiovascular outcomes.

  19. Effects of dopamine infusion on cardiac and renal blood flows in dogs.

    Science.gov (United States)

    Furukawa, Shuji; Nagashima, Yukiko; Hoshi, Katsuichiro; Hirao, Hidehiro; Tanaka, Ryou; Maruo, Kohji; Yamane, Yoshihisa

    2002-01-01

    In veterinary medicine, dopamine is currently being administered clinically by infusion for treatment of kidney disorders at low doses (high doses (> or = 5 microg/kg/min). However, since high doses of dopamine cause peripheral vasoconstriction due to its effect on alpha adrenoceptors, high doses have no longer been recommended. The present study was conducted to explore possible regimens for the use of dopamine infusion in dogs. The regional (renal and cardiac) blood flow for 60 min was measured by using colored microspheres at three doses (3, 10 and 20 microg/kg/min) of dopamine infusion in healthy anesthetized mongrel dogs. The effects on kidney and peripheral hemodynamics at each dose and the resultant cardiac output, mean arterial blood pressure and total peripheral resistance were determined. Renal blood flow increased markedly at 3 microg/kg/min dopamine. Improvement in hemodynamics indicated by marked increase in cardiac blood flow, cardiac output and mean arterial blood pressure and decreased total peripheral resistance was observed at higher doses (10 and 20 microg/kg/min). At 10 microg/kg/min, in addition to the satisfactory increase in cardiac blood flow, there was also a stable satisfactory increase in renal blood flow. However, at 20 microg/kg/min, increased myocardial oxygen consumption (manifested by marked increased in cardiac output), arrythmia and irregular increase in renal blood flow were detected. This study suggests that the clinical use of dopamine infusion in dogs could be safely expanded to moderately higher doses.

  20. Internal filtration, filtration fraction, and blood flow resistance in high- and low-flux dialyzers.

    Science.gov (United States)

    Schneditz, Daniel; Zierler, Edda; Vanholder, Raymond; Eloot, Sunny

    2014-01-01

    It was the aim to examine the fluid flow in blood and dialysate compartments of highly permeable hollow fiber dialyzers where internal filtration contributes to solute removal but where excessive filtration bears a risk of cell activation and damage. Flow characteristics of high- (HF) and low-flux (LF) dialyzers were studied in lab-bench experiments using whole bovine blood. Measurements obtained under different operating conditions and under zero net ultrafiltration were compared to theoretical calculations obtained from a mathematical model. Experimental resistances in the blood compartment were within ±2% of those calculated from the model when dialysate was used as a test fluid. With whole blood, the experimental resistances in the blood compartment were only 81.8 ± 2.8% and 83.7 ± 4.3% of those calculated for the LF and HF dialyzer, respectively. Surprisingly, measured blood flow resistance slightly but significantly decreased with increasing flow rate (p filtration fraction, while overall internal filtration increased. The increase in internal filtration when increasing blood flow is associated with a beneficial reduction in internal filtration fraction. Concerns of increased hemoconcentration when increasing blood flow therefore appear to be unwarranted.

  1. The Rheology of Blood Flow in a Branched Arterial System.

    Science.gov (United States)

    Shibeshi, Shewaferaw S; Collins, William E

    2005-01-01

    Blood flow rheology is a complex phenomenon. Presently there is no universally agreed upon model to represent the viscous property of blood. However, under the general classification of non-Newtonian models that simulate blood behavior to different degrees of accuracy, there are many variants. The power law, Casson and Carreau models are popular non-Newtonian models and affect hemodynamics quantities under many conditions. In this study, the finite volume method is used to investigate hemodynamics predictions of each of the models. To implement the finite volume method, the computational fluid dynamics software Fluent 6.1 is used. In this numerical study the different hemorheological models are found to predict different results of hemodynamics variables which are known to impact the genesis of atherosclerosis and formation of thrombosis. The axial velocity magnitude percentage difference of up to 2 % and radial velocity difference up to 90 % is found at different sections of the T-junction geometry. The size of flow recirculation zones and their associated separation and reattachment point's locations differ for each model. The wall shear stress also experiences up to 12 % shift in the main tube. A velocity magnitude distribution of the grid cells shows that the Newtonian model is close dynamically to the Casson model while the power law model resembles the Carreau model. ZUSAMMENFASSUNG: Die Rheologie von Blutströmungen ist ein komplexes Phänomen. Gegenwärtig existiert kein allgemein akzeptiertes Modell, um die viskosen Eigenschaften von Blut wiederzugeben. Jedoch gibt es mehrere Varianten unter der allgemeinen Klassifikation von nicht-Newtonschen Modellen, die das Verhalten von Blut mit unterschiedlicher Genauigkeit simulieren. Die Potenzgesetz-, Casson und Carreau-Modelle sind beliebte nicht-New-tonsche Modelle und beeinflussen die hämodynamischen Eigenschaften in vielen Situationen. In dieser Studie wurde die finite Volumenmethode angewandt, um die h

  2. Changes in interstitial K+ and pH during exercise: implications for blood flow regulation

    DEFF Research Database (Denmark)

    Juel, Carsten

    2007-01-01

    The analysis of blood samples has clearly demonstrated that exercise is associated with the release of K+ and H+ from muscle. However, blood samples give only incomplete information about the ion changes in the muscle interstitium. Interstitial changes in ion composition may affect the transport...... of fatigue. It has also been demonstrated with microdialysis that the interstitial decrease in pH during muscle activity is larger than the reduction in blood pH. Ion changes in the interstitium may affect blood flow directly or indirectly. Infusion of K+ into the femoral artery in humans has demonstrated...... that blood flow is affected by changes in K+ as low as 0.1 mmol/L. The vasodilatory effect of K+ can be inhibited with simultaneous barium infusion, indicating that inward rectifier potassium (Kir)channels are involved. Acidosis has a direct effect on blood flow and an indirect effect, mediated by changes...

  3. Short-term glucosamine infusion increases islet blood flow in anesthetized rats.

    Science.gov (United States)

    Gao, Xiang; Jansson, Leif; Persson, A Erik G; Sandberg, Monica

    2013-01-01

    Impaired glucose tolerance and type 2 diabetes in rodents are associated with increased islet blood flow. If this is important for modulation of the endocrine function is at present unknown. We evaluated if glucosamine infusion, which induces peripheral insulin resistance and glucose intolerance, could be used to acutely increase islet blood flow. We infused anaesthetized Sprague-Dawley rats for 2 h with glucosamine (6 mg/kg body weight), in some cases followed by glucose administration. The former induced a 2-fold increase in serum insulin concentrations while plasma glucose remained unchanged. In vitro an augmented insulin response to hyperglycemia and decreased insulin content in batch type islet incubations with glucosamine for 24 h were seen. After 2 h glucosamine exposure in vitro, insulin release was decreased. In vivo glucosamine infusion increased islet blood flow, without affecting other regional blood flow values. Glucose increased islet blood flow to the same extent in control and glucosamine-infused rats. When exposed to 10 mmol/L glucosamine arterioles of isolated perfused islets showed a 10% dilation of their vascular smooth muscle. Thus, application of this model leads to acute hyperinsulinemia in vivo but a decreased insulin release in vitro, which suggests that effects not located to β cells are responsible for the effects seen in vivo. An increased islet blood flow in previously healthy animals was also seen after glucose administration, which can be used to further dissect the importance of blood flow changes in islet function.

  4. Effect of Acupuncture Manipulations at LI4 or LI11 on Blood Flow and Skin Temperature.

    Science.gov (United States)

    Li, Weihui; Ahn, Andrew

    2016-06-01

    Acupuncture induces physiological changes, and patients have reported warm or cool sensations with "Burning Fire" (BF) or "Penetrating Cool" (PC) manipulations. This study aimed to evaluate whether these techniques had distinct effects on skin temperature and blood flow and to examine whether skin temperature correlated with blood flow. The participants were 25 healthy volunteers, each receiving acupuncture manipulations on points LI4 and LI11 bilaterally. Skin temperatures and blood flow were recorded continuously on both arms. The study found that acupuncture significantly increased skin temperature on the needling arm by 0.3514°C on average, but decreased it on the contralateral arm by 0.2201°C on average. Blood flow decreased significantly in both arms during needling (-3.4% and -5.97% for the ipsilateral and the contralateral sides, respectively), but the changes in skin temperature did not correlate with the changes in blood flow. Furthermore, these changes were not significantly different between acupuncture techniques and acupuncture points. In conclusion, acupuncture changes local skin temperature and blood flow independent of the manipulation technique. Moreover, blood flow may not be affected by the increased temperature on the needling arm. These results help to verify traditional Chinese medicine concepts and may help in establishing standards for acupuncture treatments.

  5. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  6. A comparative cerebral blood flow study in a baboon model with acetazolamide provocation: {sup 99m}Tc-HMPAO vs {sup 123}I(IMP)

    Energy Technology Data Exchange (ETDEWEB)

    Dormehl, I.C.; Oliver, D.W.; Hugo, N.; Rossouw, D

    1995-04-01

    Pharmacological interactions are important when nuclear medical procedures are applied to patients under drug therapy, or drug provocation. This study compares in baboon models (regional) cerebral blood flow [(r)CBF] results from {sup 99m}Tc-HMPAO and {sup 123}I-iodoamphetamine [{sup 123}I(IMP)] each with and without acetazolamide, the latter a suggested drug for testing cerebrovascular reserve. Expected differences in cerebral uptake were observed between the two radio-tracers without acetazolamide. The increase in tracer uptake resulting from acetazolamide is significantly enhanced for {sup 123}I(IMP), which could have diagnostic implications.

  7. Pulsatile magneto-hydrodynamic blood flows through porous blood vessels using a third grade non-Newtonian fluids model.

    Science.gov (United States)

    Akbarzadeh, Pooria

    2016-04-01

    In this paper, the unsteady pulsatile magneto-hydrodynamic blood flows through porous arteries concerning the influence of externally imposed periodic body acceleration and a periodic pressure gradient are numerically simulated. Blood is taken into account as the third-grade non-Newtonian fluid. Besides the numerical solution, for small Womersley parameter (such as blood flow through arterioles and capillaries), the analytical perturbation method is used to solve the nonlinear governing equations. Consequently, analytical expressions for the velocity profile, wall shear stress, and blood flow rate are obtained. Excellent agreement between the analytical and numerical predictions is evident. Also, the effects of body acceleration, magnetic field, third-grade non-Newtonian parameter, pressure gradient, and porosity on the flow behaviors are examined. Some important conclusions are that, when the Womersley parameter is low, viscous forces tend to dominate the flow, velocity profiles are parabolic in shape, and the center-line velocity oscillates in phase with the driving pressure gradient. In addition, by increasing the pressure gradient, the mean value of the velocity profile increases and the amplitude of the velocity remains constant. Also, when non-Newtonian effect increases, the amplitude of the velocity profile.

  8. The correlation between coronary flow reserve and clinical outcomes in patients with primary ;angioplasty for acute myocardial infarction with high baseline white blood cell count%基础白细胞计数增高的急性心肌梗死患者冠状动脉介入术后冠状动脉血流储备降低对远期预后的影响

    Institute of Scientific and Technical Information of China (English)

    郑振国; 周旭晨; 朱皓; 尹达; 张妍

    2014-01-01

    Objective Both abnormal coronary flow reserve (CFR) following percutaneous coronary intervention (PCI) and elevated white blood cell (WBC) count in acute myocardial infarction (AMI) are known as useful predictors for adverse outcomes. We evaluated the value of abnormal CFR for prediction of adverse outcomes in AMI patients with high baseline WBC count following primary PCI. Methods We studied 72 consecutive patients (mean age 56±12, male 55) presenting with AMI who were admitted to our institution. Analyze of CFR was performed following PCI by intra-coronary Doppler wire. All enroll patents’ baseline WBC count was obtained at admission and WBC count≥10.4×109/L. The occurrence of major adverse cardiac events (MACE) were analyzed during clinical follow up (12.7±7.1 months). According to the best cutoff value of CFR for predicting MACE, the patients were divided into 2 groups:group 1 with CFR<1.4, group 2 with CFR≥1.4. Results Baseline CK and CK-MB in group 1 were significantly higher than in group 2[(4 109±407)U/L vs. (2 685±562)U/L, P<0.05; (290.8± 26.6)ng/ml vs. (255.7±65.6)ng/ml, P<0.05 respectively]; Percent of post PCI MBG grade3 were more often in group 2 than in group 1(25.9%vs. 38.9%, P<0.05). MACE rate were significantly higher in group 1 than in group 2(40.7%vs. 27.8%, P<0.05), the mortality rate was significantly higher in group 1 than in group 2(13.0% vs. 0, P<0.05). Conclusions Abnormal CFR following PCI with high baseline WBC count in patients with AMI were associated with a higher incidence of adverse long-term clinical outcomes. This observation may provide a potential explanation that links of microvascular dysfunction and vascular inflammation in patients with AMI.%目的:急性心肌梗死(AMI)患者在接受了冠状动脉介入术(PCI)后,即刻冠状动脉血流储备(CFR)的降低,以及AMI急性期基础血液中白细胞计数的增加均被视为AMI患者远期预后不良的预测因子。我们现将这

  9. Quantification of blood perfusion using 3D power Doppler: an in-vitro flow phantom study

    Science.gov (United States)

    Raine-Fenning, N. J.; Ramnarine, K. V.; Nordin, N. M.; Campbell, B. K.

    2004-01-01

    Three-dimensional (3D) power Doppler data is increasingly used to assess and quantify blood flow and tissue perfusion. The objective of this study was to assess the validity of common 3D power Doppler ‘vascularity’ indices by quantification in well characterised in-vitro flow models. A computer driven gear pump was used to circulate a steady flow of a blood mimicking fluid through various well characterised flow phantoms to investigate the effect of the number of flow channels, flow rate, depth dependent tissue attenuation, blood mimic scatter particle concentration and ultrasound settings. 3D Power Doppler data were acquired with a Voluson 530D scanner and 7.5 MHz transvaginal transducer (GE Kretz). Virtual Organ Computer-aided Analysis software (VOCAL) was used to quantify the vascularisation index (VI), flow index (FI) and vascularisation-flow index (VFI). The vascular indices were affected by many factors, some intuitive and some with more complex or unexpected relationships (e.g. VI increased linearly with an increase in flow rate, blood mimic scatter particle concentration and number of flow channels, and had a complex dependence on pulse repetition frequency). Use of standardised settings and appropriate calibration are required in any attempt at relating ‘vascularity indices’ with flow.

  10. Effects of gestation feeding level on glycogen reserves and blood parameters in the newborn pig.

    Science.gov (United States)

    Ojamaa, K M; Elliot, J I; Hartsock, T G

    1980-09-01

    Ten Yorkshire gilts were fed either 1.36 or .45 kg of a gestation diet per day from day 85 of gestation to farrowing for determination of the effect of feed restriction during late gestation on reproductive performance. All gilts consumed 1.36 kg/day from day of breeding to day 85. Feeding level of affected (P Gestation period tended to be shorter (115.4 vs 113.6 days) and total litter weight tended to be lower (10.6 vs 8.6 kg) in the restricted group although the differences were not statistically significant. Litter size was similar (9.6 vs 9.4 pigs/litter). Restriction of gestation feed significantly reduced individual piglet birth weight (1.1 vs .9 kg), liver weight (32.9 vs 26.0 g) and skeletal muscle weights (8.9 vs 7.1 and 2.1 vs 1.6 g for the longissimus and semitendinosus muscles, respectively). Piglets born to restricted dams also had reduced liver and muscle glycogen concentrations (15.1 vs 13.9, 10.1 vs 9.4 and 9.9 vs 9.4 g/100 g of wet tissue for the liver and longissimus and semitendinosus muscles, respectively), lower (P < .05) blood pH (7.31 vs 7.23) and higher (P < .01) blood lactate levels (43.8 vs 71.3 mg/100 ml).

  11. 轴流式血泵流场CFD仿真%Flow field CFD analysis of axial flow blood pump

    Institute of Scientific and Technical Information of China (English)

    谢雄; 谭建平

    2014-01-01

    In the development of axial flow blood pump,the arterial partial flow field may produce an area with very low flow shear rate,so it is necessary to consider the non-Newtonian charac-teristics of blood fluid.In this paper,a model of axial flow blood pump was established,and flow and rotate-speed’s impacts on the inlet and outlet of the flow field in the blood pump were ana-lyzed through Computational Fluid Dynamics (CFD)simulation,as wel as the influence of the guide vane on the flow field.By the pump water experiment of the designed blood pump,its out-put flow and pressure were measured;the results show that the designed blood pump is consist-ent on the law with the simulation.%在轴流式血泵的研发过程中,动脉局部流场中可能产生流动剪切率非常低的区域,因此有必要考虑血液的非牛顿特性。建立了轴流式血泵模型,通过CFD仿真分析得到血泵转速和流量的变化对血泵出入口压力分布和速度分布的影响,并采用水和甘油(2∶1)的混合流体替代血液,对设计的血泵进行驱动实验,测量了轴流式血泵输出流量和压力参数。结果表明:所设计的血泵在规律上和仿真是相符的。

  12. [The influence of isosorbide mononitrate on skin blood flow in patients with Raynaud's syndrome].

    Science.gov (United States)

    Gross, Robert; Galus, Krzysztof; Zajac, Stanisław; Jedrasik, Maciej

    2002-01-01

    The influence of isosorbide mononitrate on skin blood flow in the pulp of finger by means of laser-Doppler flowmetry was evaluated in 19 women with Raynaud's syndrome. Skin blood flow changes were measured after cooling the hand. Isosorbide mononitrate decreased the influence of cooling on skin blood flow in the pulp of finger. This finding supports the theory that endothelial dysfunction is one of the reasons of Raynaud's syndrome. We suppose that application of isosorbide mononitrate should be useful in prevention and the treatment of Raynaud's phenomenon attacks.

  13. [Analysis of the timing parameters of blood flow in the carotid basin arteries of hypertensive patients].

    Science.gov (United States)

    Makarenko, E S

    2011-01-01

    Vascular duplex ultrasound study with simultaneous ECG recording was performed to estimate the timing parameters of blood flow in the common carotid, internal carotid, and middle cerebral arteries in patients with grades 1 and 2 arterial hypertension. There was an increase in the blood flow acceleration phase index in the common carotid and middle cerebral arteries and a reduction in the systolic phase index in the internal carotid arteries. There were correlations of phasic blood flow parameters in the extra- and intracranial arteries with age and lipidogram readings.

  14. The effect of 0.5% ropivacaine on epidural blood flow

    DEFF Research Database (Denmark)

    Dahl, J B; Simonsen, L; Mogensen, T;

    1990-01-01

    Twenty patients scheduled for elective abdominal surgery received epidural analgesia with 20 ml 0.5% ropivacaine or 0.5% bupivacaine. Epidural blood flow was measured by an epidural 133Xe clearance technique on the day before surgery (no local anaesthetic) and again 1 h before surgery, 30 min after...... injection of the local anaesthetic during continuous infusion (8 ml/h). Median initial blood flow was 5.0 ml/min and 6.0 ml/min per 100 g tissue in patients receiving ropivacaine and bupivacaine, respectively. After epidural bupivacaine, blood flow increased in 8 of 10 patients to 6.9 ml/min per 100 g...

  15. Synchronized renal blood flow dynamics mapped with wavelet analysis of laser speckle flowmetry data

    DEFF Research Database (Denmark)

    Brazhe, Alexey R; Marsh, Donald J; von Holstein-Rathlou, Niels-Henrik;

    2014-01-01

    Full-field laser speckle microscopy provides real-time imaging of superficial blood flow rate. Here we apply continuous wavelet transform to time series of speckle-estimated blood flow from each pixel of the images to map synchronous patterns in instantaneous frequency and phase on the surface...... of rat kidneys. The regulatory mechanism in the renal microcirculation generates oscillations in arterial blood flow at several characteristic frequencies. Our approach to laser speckle image processing allows detection of frequency and phase entrainments, visualization of their patterns, and estimation...

  16. Numerical methods for simulating blood flow at macro, micro, and multi scales.

    Science.gov (United States)

    Imai, Yohsuke; Omori, Toshihiro; Shimogonya, Yuji; Yamaguchi, Takami; Ishikawa, Takuji

    2016-07-26

    In the past decade, numerical methods for the computational biomechanics of blood flow have progressed to overcome difficulties in diverse applications from cellular to organ scales. Such numerical methods may be classified by the type of computational mesh used for the fluid domain, into fixed mesh methods, moving mesh (boundary-fitted mesh) methods, and mesh-free methods. The type of computational mesh used is closely related to the characteristics of each method. We herein provide an overview of numerical methods recently used to simulate blood flow at macro and micro scales, with a focus on computational meshes. We also discuss recent progress in the multi-scale modeling of blood flow.

  17. Ultrasound tagged near infrared spectroscopy does not detect hyperventilation-induced reduction in cerebral blood flow

    DEFF Research Database (Denmark)

    Lund, Anton; Secher, Niels H; Hirasawa, Ai;

    2016-01-01

    INTRODUCTION: Continuous non-invasive monitoring of cerebral blood flow (CBF) may be important during anaesthesia and several options are available. We evaluated the CerOx monitor that employs ultrasound tagged near infrared spectroscopy to estimate changes in a CBF index (CFI). METHODS: Seven...... by transcranial Doppler. Blood flow in the internal and external carotid artery (ICAf and ECAf) was determined using duplex ultrasonography and forehead skin blood flow (SkBF) and oxygenation (SskinO2) by laser Doppler and white light spectroscopy. RESULTS: During hyperventilation MCAvmean and ICAf decreased...

  18. Measurement of real pulsatile blood flow using X-ray PIV technique with CO2 microbubbles.

    Science.gov (United States)

    Park, Hanwook; Yeom, Eunseop; Seo, Seung-Jun; Lim, Jae-Hong; Lee, Sang-Joon

    2015-03-06

    Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO2 microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO2 microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases.

  19. Disodium cromoglycate, a mast-cell stabilizer, alters postradiation regional cerebral blood flow in primates

    Energy Technology Data Exchange (ETDEWEB)

    Cockerham, L.G.; Doyle, T.F.; Pautler, E.L.; Hampton, J.D.

    1986-01-01

    Early transient incapacitation (ETI) is the complete cessation of performance during the first 30 min after radiation exposure, and performance decrement (PD) is a reduction in performance at the same time. Supralethal doses of radiation have been shown to produce a marked decrease in regional cerebral blood flow in primates concurrent with systemic hypotension and a dramatic release of mast-cell histamine. In an attempt to elucidate mechanisms underlying the radiation-induced ETI/PD phenomena and the postradiation decrease in cerebral blood flow, primates were given the mast-cell stabilizers disodium cromoglycate (DSCG) or BRL 22321 before exposure to 100 Gy whole-body gamma radiation. Hypothalamic and cortical blood flows were measured by hydrogen clearance, before and after radiation exposure. Systemic blood pressures were determined simultaneously. The data indicated that DSCG was successful in diminishing postradiation decrease in cerebral blood flow. Irradiated animals pretreated with DSCG, showed only a 10% decrease in hypothalamic blood flow 60 min postradiation, while untreated, irradiated animals showed a 57% decrease. The cortical blood flow of DSCG treated, irradiated animals showed a triphasic response, with a decrease of 38% at 10 min postradiation, then a rise to 1% below baseline at 20 min, followed by a fall to 42% below baseline by 50 min postradiation. In contrast, the untreated, irradiated animals showed a steady decrease in cortical blood flow to 79% below baseline by 50 min postradiation. There was no significant difference in blood-pressure response between the treated and untreated, irradiated animals. Systemic blood pressure showed a 60% decrease at 10 min postradiation, falling to a 71% decrease by 60 min.

  20. Hybrid PIV-PTV technique for measuring blood flow in rat mesenteric vessels.

    Science.gov (United States)

    Ha, Hojin; Nam, Kweon-Ho; Lee, Sang Joon

    2012-11-01

    The micro-particle tracking velocimetry (μ-PTV) technique is used to obtain the velocity fields of blood flow in the microvasculature under in vivo conditions because it can provide the blood velocity distribution in microvessels with high spatial resolution. The in vivo μ-PTV technique usually requires a few to tens of seconds to obtain a whole velocity profile across the vessel diameter because of the limited number density of tracer particles under in vivo conditions. Thus, the μ-PTV technique alone is limited in measuring unsteady blood flows that fluctuate irregularly due to the heart beating and muscle movement in surrounding tissues. In this study, a new hybrid PIV-PTV technique was established by combining PTV and particle image velocimetry (PIV) techniques to resolve the drawbacks of the μ-PTV method in measuring blood flow in microvessels under in vivo conditions. Images of red blood cells (RBCs) and fluorescent particles in rat mesenteric vessels were obtained simultaneously. Temporal variations of the centerline blood velocity were monitored using a fast Fourier transform-based cross-correlation PIV method. The fluorescence particle images were analyzed using the μ-PTV technique to extract the spatial distribution of the velocity vectors. Data from the μ-PTV and PIV methods were combined to obtain a better estimate of the velocity profile in actual blood flow. This technique will be useful in investigating hemodynamics in microcirculation by measuring unsteady irregular blood flows more accurately.