WorldWideScience

Sample records for blood collection system

  1. Modeling and simulation of blood collection systems.

    Science.gov (United States)

    Alfonso, Edgar; Xie, Xiaolan; Augusto, Vincent; Garraud, Olivier

    2012-03-01

    This paper addresses the modeling and simulation of blood collection systems in France for both fixed site and mobile blood collection with walk in whole blood donors and scheduled plasma and platelet donors. Petri net models are first proposed to precisely describe different blood collection processes, donor behaviors, their material/human resource requirements and relevant regulations. Petri net models are then enriched with quantitative modeling of donor arrivals, donor behaviors, activity times and resource capacity. Relevant performance indicators are defined. The resulting simulation models can be straightforwardly implemented with any simulation language. Numerical experiments are performed to show how the simulation models can be used to select, for different walk in donor arrival patterns, appropriate human resource planning and donor appointment strategies.

  2. An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System.

    Science.gov (United States)

    George, Paul E; Vidal, Julio; Garcia, Patricia J

    2016-05-01

    Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Every Peruvian blood bank was evaluated by MINSA from 2007-2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product.

  3. Effectiveness of a Novel Specimen Collection System in Reducing Blood Culture Contamination Rates.

    Science.gov (United States)

    Bell, Mary; Bogar, Catherine; Plante, Jessica; Rasmussen, Kristen; Winters, Sharon

    2018-04-20

    False-positive blood-culture results due to skin contamination of samples remain a persistent problem for health care providers. Our health system recognized that our rates of contamination across the 4 emergency department campuses were above the national average. A unique specimen collection system was implemented throughout the 4 emergency departments and became the mandatory way to collect adult blood cultures. The microbiology laboratory reported contamination rates weekly to manage potential problems; 7 months of data are presented here. There was an 82.8% reduction in false positives with the unique specimen collection system compared with the standard method (chi-squared test with Yates correction, 2-tailed, P = 0.0001). Based on the historical 3.52% rate of blood-culture contamination for our health facilities, 2.92 false positives were prevented for every 100 blood cultures drawn, resulting from adoption of the unique specimen collection system as the standard of care. This unique collection system can reduce the risk of blood culture contamination significantly and is designed to augment, rather than replace, the standard phlebotomy protocol already in use in most health care settings. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. 21 CFR 864.9125 - Vacuum-assisted blood collection system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125 Section 864.9125 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  5. Relevance of EDTA carryover during blood collection.

    Science.gov (United States)

    Cadamuro, Janne; Felder, Thomas Klaus; Oberkofler, Hannes; Mrazek, Cornelia; Wiedemann, Helmut; Haschke-Becher, Elisabeth

    2015-07-01

    The order of draw is regarded as a preanalytical issue to prevent carryover of additives during blood collection. Our objective was to prove the theory of ethylenediaminetetraacetic acid (EDTA) carryover for a closed vacuum system and the influence of EDTA on concentrations of selected biomarkers. To test the carryover of EDTA, a blood collection with tripotassium EDTA (K3EDTA) and subsequent non-additive tubes was simulated using distilled water as substitute for blood. EDTA concentrations were measured by tandem mass spectrometry. Then we added increasing concentrations of EDTA to heparinized blood and measured routine biomarkers, thereby simulating a carryover of EDTA whole blood and pure EDTA, respectively. Additionally, we tested for EDTA contamination and biomarker alteration in samples collected from 10 healthy volunteers by a syringe with subsequent transfer into sample tubes. No EDTA contamination was detected in samples collected subsequent to a K3EDTA tube when adhering to guidelines of blood sampling. Magnesium, calcium, and potassium levels were altered by artificial K3EDTA whole-blood contamination as well as when adding 1 μL pure K3EDTA. Iron values were altered at EDTA concentrations of 4.4 mmol/L. All other parameters remained unaffected. A slight EDTA carryover was observed in syringe collection and subsequent transfer into EDTA and heparin tubes, however, without any biomarker alteration. An EDTA carryover during blood collection using a closed vacuum system is highly unlikely. Even if carryover of EDTA whole blood occurs, an absolute volume larger than 10 μL would be necessary to alter test results. However, contamination of samples with preloaded pure K3EDTA solution by severe neglect of current recommendations in blood collection may significantly alter testing results.

  6. Epidemiology of blood collection in France

    International Nuclear Information System (INIS)

    Lawson-Ayayi, S.; Salmi, L.R.

    1999-01-01

    The objectives of the cross-sectional study (EpiCoS) were to describe, at different stages, volunteers offering their blood, and to characterize various ways of collecting blood. From 15 September 1996 to 31 December 1996, individuals presenting at fixed or mobile sessions in one of 11 randomly selected blood banks were included after they had a medical examination. Variables studied were relative to type of collection, individuals, medical examination, patterns of blood letting, use of collected donations and if unused, reasons for discarding. Sixty four thousand and ninety two volunteers, aged 17-66 years old were included. The proportion of exclusion during medical examination was 10.8% (95% confidence interval (CI): 10.6-11.0%). Exclusions were more frequent among new volunteers and were mostly related to the safety of recipients. Most of the 57,003 donations were whole blood (94.0%) and collected in mobile sessions (89.9%). Five percent of collected donations were discarded; 3.5% (95% CI: 3.4-3.7%) of donations discarded for biological abnormalities, including 1.5% only for initial screen reactions to infectious disease markers (HBs antigen, anti-HBc antibodies, anti-HCV antibodies, anti-HIV antibodies, anti-HTLV antibodies, malaria antibodies and anti-syphilitic antibodies). The most frequent biological abnormality was a high alanine aminotransferase level. A follow-up of these indicators, within the French haemovigilance system, should allow further identification of risk factors and high-risk contexts, and planning means of optimizing blood collection in France

  7. Automatic collection of bovine blood samples | Hale | South African ...

    African Journals Online (AJOL)

    A technique is described which allows automatic collection of jugular venous blood from tethered cows. In this system, blood is pumped continuously from an intravenous cannula which has a double lumen while an anticoagulant is pumped through the second opening. Diluted blood is collected in a fraction collector which ...

  8. Designing an automated blood fractionation system.

    Science.gov (United States)

    McQuillan, Adrian C; Sales, Sean D

    2008-04-01

    UK Biobank will be collecting blood samples from a cohort of 500 000 volunteers and it is expected that the rate of collection will peak at approximately 3000 blood collection tubes per day. These samples need to be prepared for long-term storage. It is not considered practical to manually process this quantity of samples so an automated blood fractionation system is required. Principles of industrial automation were applied to the blood fractionation process leading to the requirement of developing a vision system to identify the blood fractions within the blood collection tube so that the fractions can be accurately aspirated and dispensed into micro-tubes. A prototype was manufactured and tested on a range of human blood samples collected in different tube types. A specially designed vision system was capable of accurately measuring the position of the plasma meniscus, plasma/buffy coat interface and the red cells/buffy coat interface within a vacutainer. A rack of 24 vacutainers could be processed in blood fractionation system offers a solution to the problem of processing human blood samples collected in vacutainers in a consistent manner and provides a means of ensuring data and sample integrity.

  9. Umbilical Cord Blood: Counselling, Collection, and Banking.

    Science.gov (United States)

    Armson, B Anthony; Allan, David S; Casper, Robert F

    2015-09-01

    bone marrow or peripheral stem cell transplantation to treat malignant and non-malignant conditions in children and adults. There is minimal harm to the mother or newborn provided that priority is given to maternal/newborn safety during childbirth management. Recipients of umbilical cord stem cells may experience graft-versus-host disease, transfer of infection or genetic abnormalities, or therapeutic failure. The financial burden on the health system for public cord blood banking and on families for private cord blood banking is considerable. Recommendations 1. Health care professionals should be well-informed about cord blood collection and storage and about factors that influence the volume, quality, and ability to collect a cord blood unit. (III-A) 2. Health care professionals caring for women and families who choose private umbilical cord blood banking must disclose any financial interests or potential conflicts of interest. (III-A) 3. Pregnant women should be provided with unbiased information about umbilical cord blood banking options, including the benefits and limitations of public and private banks. (III-A) 4. Health care professionals should obtain consent from mothers for the collection of umbilical cord blood prior to the onset of active labour, ideally during the third trimester, with ample time to address any questions. (III-A) 5. Health care professionals must be trained in standardized procedures (ex utero and in utero techniques) for cord blood collection to ensure the sterility and quality of the collected unit. (II-2A) 6. Umbilical cord blood should be collected with the goal of maximizing the content of hematopoietic progenitors through the volume collected. The decision to bank the unit will depend upon specific measures of graft potency. (II-2A) 7. Umbilical cord blood collection must not adversely affect the health of the mother or newborn. Cord blood collection should not interfere with delayed cord clamping. (III-E) 8. Health care

  10. Bloody Fast Blood Collection

    NARCIS (Netherlands)

    van Brummelen, Samuel Pieter Josephus

    2017-01-01

    This thesis consists of four parts: The first part contains an introduction, the second presents approaches for the evaluation of waiting times at blood collection sites, the third uses these to present approaches that improve waiting times at blood collection sites. The final part shows the

  11. Blood collection and the labile blood components: what should the regulators ask for?

    Science.gov (United States)

    Maniatis, A; Adamides, E

    1998-01-01

    Efforts to promote the quality and safety of blood collection are underway in most European Union (EU) member states but the level of quality management continues to differ significantly not only between countries but also among Blood Collection Establishments (BCE's) within a country. The European Commission has asked for blood safety and self-sufficiency in the Community and has initiated action in this direction. What is sought is harmonization of practices in the transfusion chain but such cannot be accomplished solely through recommendations and directives given the sociocultural and economic differences among EU member states. Active support for the development of common standards and a common quality system as well as an inspection and accreditation system would certainly help. The goal of self-sufficiency should certainly be emphasized but may be difficult to achieve, given the unpredictability of factors that may affect demand and supply. Through bipartisan initiatives however, between the USA and EU, consensus regarding the issue of blood safety, could be reached.

  12. Impact of blood collection and processing on peripheral blood gene expression profiling in type 1 diabetes.

    Science.gov (United States)

    Yip, Linda; Fuhlbrigge, Rebecca; Atkinson, Mark A; Fathman, C Garrison

    2017-08-18

    The natural history of type 1 diabetes (T1D) is challenging to investigate, especially as pre-diabetic individuals are difficult to identify. Numerous T1D consortia have been established to collect whole blood for gene expression analysis from individuals with or at risk to develop T1D. However, with no universally accepted protocol for their collection, differences in sample processing may lead to variances in the results. Here, we examined whether the choice of blood collection tube and RNA extraction kit leads to differences in the expression of genes that are changed during the progression of T1D, and if these differences could be minimized by measuring gene expression directly from the lysate of whole blood. Microarray analysis showed that the expression of 901 genes is highly influenced by sample processing using the PAXgene versus the Tempus system. These included a significant number of lymphocyte-specific genes and genes whose expression has been reported to differ in the peripheral blood of at-risk and T1D patients compared to controls. We showed that artificial changes in gene expression occur when control and T1D samples were processed differently. The sample processing-dependent differences in gene expression were largely due to loss of transcripts during the RNA extraction step using the PAXgene system. The majority of differences were not observed when gene expression was measured in whole blood lysates prepared from blood collected in PAXgene and Tempus tubes. We showed that the gene expression profile of samples processed using the Tempus system is more accurate than that of samples processed using the PAXgene system. Variation in sample processing can result in misleading changes in gene expression. However, these differences can be minimized by measuring gene expression directly in whole blood lysates.

  13. Human blood RNA stabilization in samples collected and transported for a large biobank

    Science.gov (United States)

    2012-01-01

    Background The Norwegian Mother and Child Cohort Study (MoBa) is a nation-wide population-based pregnancy cohort initiated in 1999, comprising more than 108.000 pregnancies recruited between 1999 and 2008. In this study we evaluated the feasibility of integrating RNA analyses into existing MoBa protocols. We compared two different blood RNA collection tube systems – the PAXgene™ Blood RNA system and the Tempus™ Blood RNA system - and assessed the effects of suboptimal blood volumes in collection tubes and of transportation of blood samples by standard mail. Endpoints to characterize the samples were RNA quality and yield, and the RNA transcript stability of selected genes. Findings High-quality RNA could be extracted from blood samples stabilized with both PAXgene and Tempus tubes. The RNA yields obtained from the blood samples collected in Tempus tubes were consistently higher than from PAXgene tubes. Higher RNA yields were obtained from cord blood (3 – 4 times) compared to adult blood with both types of tubes. Transportation of samples by standard mail had moderate effects on RNA quality and RNA transcript stability; the overall RNA quality of the transported samples was high. Some unexplained changes in gene expression were noted, which seemed to correlate with suboptimal blood volumes collected in the tubes. Temperature variations during transportation may also be of some importance. Conclusions Our results strongly suggest that special collection tubes are necessary for RNA stabilization and they should be used for establishing new biobanks. We also show that the 50,000 samples collected in the MoBa biobank provide RNA of high quality and in sufficient amounts to allow gene expression analyses for studying the association of disease with altered patterns of gene expression. PMID:22988904

  14. Study on chromosome aberrations test determinated by micro-whole blood culture in vacuum blood collection tube

    International Nuclear Information System (INIS)

    Zhong Zhihong; Han Fang'an; Ge Qinjuan; Wu Xiao; Chen Juan

    2006-01-01

    Objective: To develop an easier and efficient method of culturing the chromosome and analyzing the aberrations in peripheral lymphocytes. Methods: Micro whole was cultured for 54 hours in home-made vacuum blood collection tube, and then collection, slice-making, microscopy detection for the chromosome aberrations was done. The difference of the results was analysed by comparing with the common method. Results: For 60 radiologists and 30 contrasts, the chromosome aberrations in peripheral lymphocytes were examed by this system, the lymphocytes and chromosome were clear and alive and easier to analyse. Compared with the common method, there was no significantly difference between the two analyzing results. Conclusion: The chromosome aberrations test by micro whole blood culture in vacuum blood collection tube is easier and efficient, and is worthy of being widely popularized. (authors)

  15. Peripheral blood collection

    DEFF Research Database (Denmark)

    Franken, Carmen; Remy, Sylvie; Lambrechts, Nathalie

    2016-01-01

    A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of mRNA in the prese......A crucial challenge for gene expression analysis in human biomonitoring studies on whole blood samples is rapid sample handling and mRNA stabilization. This study was designed to evaluate the impact of short bench times (less than 30 min) on yield, quality and gene expression of m......RNA in the presence of different stabilization buffers (TempusTM Blood RNA tube and RNAlater® Stabilization Reagent). Microarray analyzes showed significant changes over short periods of time in expression of a considerate part of the transcriptome (2356 genes) with a prominent role for NFкB-, cancer......- and glucocorticoid-mediated networks, and specifically interleukin-8 (IL-8). These findings suggest that even short bench times affect gene expression, requiring to carry out blood collection in a strictly standardized way. © 2016 Informa UK Limited, trading as Taylor & Francis Group....

  16. 21 CFR 640.64 - Collection of blood for Source Plasma.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Collection of blood for Source Plasma. 640.64... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.64 Collection of blood for Source Plasma. (a) Supervision. All blood for the collection of Source Plasma shall...

  17. Optimal method for collection of umbilical cord blood: an Egyptian trial for a public cord blood bank.

    Science.gov (United States)

    Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A

    2015-06-01

    Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.

  18. Ion suppression from blood collection devices

    DEFF Research Database (Denmark)

    Hasselstrøm, Jørgen Bo; Sejr Gothelf, Aase

    The aim of the study was to examine the variation in ion suppression in ultra high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS-MS) methods when using different blood collection devices. Three different methods measuring 18 antidepressants and antipsychotics in total were...... Terumo, S-monovette from Sarstedt, Vacuette from Greiner Bio-One and three BD Vacutainer serum tubes from BD. These seven different blood collection devices were used to withdraw blood from five healthy drug free donors (n=35) in random order. The samples were centrifuged and serum from each sample...... by UHPLC-MS-MS using three different gradients (Group I, II and III). The analytes in group I was measured on an Agilent 6460 mass spectrometer and group II and III were measured on an Agilent 6410 mass spectrometer both utilizing positive electrospray ionization. The experiments demonstrated significant...

  19. Good practices in collecting umbilical cord and placental blood

    Directory of Open Access Journals (Sweden)

    Lauren Auer Lopes

    Full Text Available Abstract Objective: to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. Method: this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1 verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2 definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r and R(r. Results: while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. Conclusion: the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality.

  20. Evaluation of a novel dried blood spot collection device (HemaSpot™) to test blood samples collected from dogs for antibodies to Leishmania infantum.

    Science.gov (United States)

    Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S

    2014-09-15

    Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test

  1. The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts.

    Science.gov (United States)

    Mrazek, Cornelia; Simundic, Ana-Maria; Wiedemann, Helmut; Krahmer, Florian; Felder, Thomas Klaus; Kipman, Ulrike; Hoppe, Uta; Haschke-Becher, Elisabeth; Cadamuro, Janne

    2017-07-26

    Blood collection through intravenous (IV) catheters is a common practice at emergency departments (EDs). This technique is associated with higher in vitro hemolysis rates and may even be amplified by the use of vacuum collection tubes. Our aim was to investigate the association of five different vacuum tubes with hemolysis rates in comparison to an aspiration system under real-life conditions and to propose an equation to estimate the amount of hemolysis, depending on the vacuum collection tube type. We retrospectively evaluated hemolysis data of plasma samples from our ED, where blood is drawn through IV catheters. Over the past 5 years, we compared 19,001 hemolysis index values amongst each other and against the respective vacuum pressure (Pv) of the collection tubes, which were used within the six observational periods. The highest hemolysis rates were associated with full-draw evacuated tubes. Significantly reduced hemolysis was observed for two kinds of partial-draw tubes. The hemolysis rate of one partial-draw blood collection tube was comparable to those of the aspiration system. Regression analysis of Pv and mean free hemoglobin (fHb) values yielded the formula fHb (g/L)=0.0082*Pv2-0.1143*Pv+ 0.5314 with an R2 of 0.99. If IV catheters are used for blood collection, hemolysis rates directly correlate with the vacuum within the tubes and can be estimated by the proposed formula. By the use of partial-draw vacuum blood collection tubes, hemolysis rates in IV catheter collections can be reduced to levels comparable with collections performed by aspiration systems.

  2. 76 FR 48167 - Agency Information Collection Activities; Proposed Collection; Comment Request; Blood...

    Science.gov (United States)

    2011-08-08

    ... requirements in the Agency's regulations and Form FDA 2830. DATES: Submit either electronic or written comments on the collection of information by October 7, 2011. ADDRESSES: Submit electronic comments on the... plasma donor centers, blood banks, certain transfusion services, other blood product manufacturers, and...

  3. Effect of hypergravity on catecholamine levels in telemetrically collected blood of rats during centrifugation

    Science.gov (United States)

    Kvetnansky, R.; Petrak, J.; Mravec, B.; Tillinger, A.; Jurani, M.; Baranovska, M.; Hapala, I.; Frollo, I.

    2005-08-01

    Hypergravity is known to activate the sympathoadrenal system (SAS). Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI) and partly also norepinephrine (NE). However, the collection of blood was performed after centrifugation finished and therefore plasma NE and EPI levels could have been affected by the process of deceleration. The aim of this study was to evaluate plasma EPI and NE levels in blood collected directly during the centrifugation after reaching different +G, using newly developed remote controlled equipment. Such telemetrically regulated equipment for multiple blood sampling allows us to investigate selective effects of hypergravity during centrifugation. All animals had a polyethylene tubing in the tail artery which was connected to a pre-programmed device for three blood withdrawals (0.6 ml each) into individual syringes, performed at any chosen time intervals. Plasma EPI and NE levels were measured at hypergravity between +1G - +5G. Plasma EPI levels showed a huge, hypergravity dependent increase at the interval of 10-20 min. After the blood collection was completed, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples plasma EPI levels showed a significant reduction compared to the 20 min interval of centrifugation but the EPI levels at 4G-6G were still significantly elevated compared to pre- centrifugation levels. Plasma NE levels showed less pronounced changes (increased after 6G only) with a slower return to control levels.Thus, our data has shown completely different responses of the adrenomedullary (epinephrine) and sympathoneural (norepinephrine) systems to hypergravitation. This data shows that the increased gravitation and not the stressful situations connected with centrifugation is the factor responsible for massive activation of the adrenomedullary system. The mechanism of small activation of the

  4. Cost-effectiveness of alternative changes to a national blood collection service.

    Science.gov (United States)

    Willis, S; De Corte, K; Cairns, J A; Zia Sadique, M; Hawkins, N; Pennington, M; Cho, G; Roberts, D J; Miflin, G; Grieve, R

    2018-05-16

    To evaluate the cost-effectiveness of changing opening times, introducing a donor health report and reducing the minimum inter-donation interval for donors attending static centres. Evidence is required about the effect of changes to the blood collection service on costs and the frequency of donation. This study estimated the effect of changes to the blood collection service in England on the annual number of whole-blood donations by current donors. We used donors' responses to a stated preference survey, donor registry data on donation frequency and deferral rates from the INTERVAL trial. Costs measured were those anticipated to differ between strategies. We reported the cost per additional unit of blood collected for each strategy versus current practice. Strategies with a cost per additional unit of whole blood less than £30 (an estimate of the current cost of collection) were judged likely to be cost-effective. In static donor centres, extending opening times to evenings and weekends provided an additional unit of whole blood at a cost of £23 and £29, respectively. Introducing a health report cost £130 per additional unit of blood collected. Although the strategy of reducing the minimum inter-donation interval had the lowest cost per additional unit of blood collected (£10), this increased the rate of deferrals due to low haemoglobin (Hb). The introduction of a donor health report is unlikely to provide a sufficient increase in donation frequency to justify the additional costs. A more cost-effective change is to extend opening hours for blood collection at static centres. © 2018 The Authors. Transfusion Medicine published by John Wiley & Sons Ltd on behalf of British Blood Transfusion Society.

  5. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  6. An analysis of mobile whole blood collection labor efficiency.

    Science.gov (United States)

    Rose, William N; Dayton, Paula J; Raife, Thomas J

    2011-07-01

    Labor efficiency is desirable in mobile blood collection. There are few published data on labor efficiency. The variability in the labor efficiency of mobile whole blood collections was analyzed. We determined to improve our labor efficiency using lean manufacturing principles. Workflow changes in mobile collections were implemented with the goal of minimizing labor expenditures. To measure success, data on labor efficiency measured by units/hour/full-time equivalent (FTE) were collected. The labor efficiency in a 6-month period before the implementation of changes, and in months 1 to 6 and 7 to 12 after implementation was analyzed and compared. Labor efficiency in the 6-month period preceding implementation was 1.06 ± 0.4 units collected/hour/FTE. In months 1 to 6, labor efficiency declined slightly to 0.92 ± 0.4 units collected/hour/FTE (p = 0.016 vs. preimplementation). In months 7 to 12, the mean labor efficiency returned to preimplementation levels of 1.09 ±0.4 units collected/hour/FTE. Regression analysis correlating labor efficiency with total units collected per drive revealed a strong correlation (R(2) = 0.48 for the aggregate data from all three periods), indicating that nearly half of labor efficiency was associated with drive size. The lean-based changes in workflow were subjectively favored by employees and donors. The labor efficiency of our mobile whole blood drives is strongly influenced by size. Larger drives are more efficient, with diminishing returns above 40 units collected. Lean-based workflow changes were positively received by employees and donors. © 2011 American Association of Blood Banks.

  7. Collection and Transfusion of Blood in Jos University Teaching ...

    African Journals Online (AJOL)

    Objective: This study was embarked on to investigate the pattern of blood collection and transfusion in Jos University Teaching Hospital (JUTH), Jos between 2000 and 2005 in the face of the present human immunodeficiency virus (HIV) pandemic. Methodology: Blood bank records of blood donors and transfusions were ...

  8. Effects of blood collection conditions on ovarian cancer serum markers.

    Directory of Open Access Journals (Sweden)

    Jason D Thorpe

    2007-12-01

    Full Text Available Evaluating diagnostic and early detection biomarkers requires comparing serum protein concentrations among biosamples ascertained from subjects with and without cancer. Efforts are generally made to standardize blood processing and storage conditions for cases and controls, but blood sample collection conditions cannot be completely controlled. For example, blood samples from cases are often obtained from persons aware of their diagnoses, and collected after fasting or in surgery, whereas blood samples from some controls may be obtained in different conditions, such as a clinic visit. By measuring the effects of differences in collection conditions on three different markers, we investigated the potential of these effects to bias validation studies.We analyzed serum concentrations of three previously studied putative ovarian cancer serum biomarkers-CA 125, Prolactin and MIF-in healthy women, women with ovarian cancer undergoing gynecologic surgery, women undergoing surgery for benign ovary pathology, and women undergoing surgery with pathologically normal ovaries. For women undergoing surgery, a blood sample was collected either in the clinic 1 to 39 days prior to surgery, or on the day of surgery after anesthesia was administered but prior to the surgical procedure, or both. We found that one marker, prolactin, was dramatically affected by collection conditions, while CA 125 and MIF were unaffected. Prolactin levels were not different between case and control groups after accounting for the conditions of sample collection, suggesting that sample ascertainment could explain some or all of the previously reported results about its potential as a biomarker for ovarian cancer.Biomarker validation studies should use standardized collection conditions, use multiple control groups, and/or collect samples from cases prior to influence of diagnosis whenever feasible to detect and correct for potential biases associated with sample collection.

  9. Biomonitoring of ciguatoxin exposure in mice using blood collection cards.

    Science.gov (United States)

    Bottein Dechraoui, M-Yasmine; Wang, Zhihong; Turquet, Jean; Chinain, Mireille; Darius, Taiana; Cruchet, Philippe; Radwan, Faisal F Y; Dickey, Robert W; Ramsdell, John S

    2005-09-01

    Ciguatera is a human food poisoning caused by consumption of tropical and subtropical fish that have, through their diet, accumulated ciguatoxins in their tissues. This study used laboratory mice to investigate the potential to apply blood collection cards to biomonitor ciguatoxin exposure. Quantitation by the neuroblastoma cytotoxicity assay of Caribbean ciguatoxin (C-CTX-1) spiked into mice blood was made with good precision and recovery. The blood collected from mice exposed to a sublethal dose of Caribbean ciguatoxic extract (0.59 ng/g C-CTX-1 equivalents) was analyzed and found to contain detectable toxin levels at least 12 h post-exposure. Calculated concentration varied from 0.25 ng/ml at 30 min post-exposure to 0.12 ng/ml at 12 h. A dose response mice exposure revealed a linear dose-dependent increase of ciguatoxin activity in mice blood, with more polar ciguatoxin congeners contributing to 89% of the total toxicity. Finally, the toxin measurement in mice blood exposed to toxic extracts from the Indian Ocean or from the Pacific Ocean showed that the blood collection card method could be extended to each of the three known ciguatoxin families (C-CTX, I-CTX and P-CTX). The low matrix effect of extracted dried-blood samples (used at 1:10 or 1:20 dilution) and the high sensitivity of the neuroblastoma assay (limit of detection 0.006 ng/ml C-CTX-1), determined that the blood collection card method is suitable to monitor ciguatoxin at sublethal doses in mice and opens the potential to be a useful procedure for fish screening, environmental risk assessment or clinical diagnosis of ciguatera fish poisoning in humans or marine mammals.

  10. One System for Blood Program Information Management

    Science.gov (United States)

    Gero, Michael G.; Klickstein, Judith S.; Hurst, Timm M.

    1980-01-01

    A system which integrates the diverse functions of a Blood Program within one structure is being assembled at the American National Red Cross Blood Services, Northeast Region. When finished, it will provide technical support for collection scheduling, donor recruitment, recordkeeping, laboratory processing, inventory management, HLA typing and matching, distribution, and administration within the Program. By linking these applications, a reporting structure useful to top management will be provided.

  11. The cost of blood collection in Greece: an economic analysis.

    Science.gov (United States)

    Fragoulakis, Vassilis; Stamoulis, Kostas; Grouzi, Elisabeth; Maniadakis, Nikolaos

    2014-07-01

    The goal of this study was to estimate the cost of production of 1 unit of blood from a National Health Service perspective in Greece. In agreement with guidelines, the cost of blood production in this study accounted only for the resources expended for collection, processing, laboratory testing, and storage. Hence, the costs associated with donor recruitment, pretransfusion preparation, transfusion administration, follow-up management of adverse events, and other long-term relevant costs were not taken into consideration. The indirect cost of blood donations for donors (productivity loss) was also considered. A questionnaire was used to collect data regarding personnel time, annual blood quantities collected, percentage of wastage, utilization of consumables, institutional overhead, information technology expenditure, medical equipment utilized, nuclear acid tests, and other factors. Data gathered by 53 hospitals across the country were assessed. A model was constructed with economic data collected by the National School of Public Health and the Ministry of Health. All data refer to the year 2013. The weighted mean direct cost of producing 1 unit of blood was estimated at €131.49 (SD, €22.12; minimum/maximum, €94.96-€239.20). The mean total indirect cost was estimated at €34 per unit of blood. The cost distribution was positively skewed (skewness, 1.642 [0.327]). The major cost component was the cost of personnel, accounting for 32.5% of total costs, and the average of blood unit wastage was estimated at 4.90%. There were no differences between the cost of producing 1 unit of blood in Athens compared with the rest of the country (Mann-Whitney test, P = 0.341). This study suggests that the cost of producing 1 unit of blood is not insignificant. These figures need to be complemented with those concerning the cost of transfusion to have a complete picture of producing and using 1 unit of blood locally. Copyright © 2014 Elsevier HS Journals, Inc. All

  12. Effect of blood collection technique in mice on clinical pathology parameters.

    Science.gov (United States)

    Schnell, Michael A; Hardy, Christine; Hawley, Melanie; Propert, Kathleen Joy; Wilson, James M

    2002-01-01

    A study was conducted in normal healthy C57BL/6 mice to determine the effect of method of blood collection on clinical pathology parameters and to provide value ranges for these parameters. Males and females were used and were randomly assigned to treatment groups based upon phlebotomy method. The blood was collected using one of four methods: intracardiac (IC), a single attempt at collection from the caudal vena cava (VC), collection from the caudal vena cava with collection of any extravasated blood from the peritoneum (MC), or retroorbital phlebotomy (RO). Evaluation of blood and serum samples was conducted for a number of serum biochemistries including liver function tests and complete blood count with differentials and platelet counts. Female mice demonstrated higher values for red blood cell number, hemoglobin (p values for platelet counts, specific white blood cell numbers (total, neutrophil, lymphocyte, and eosinophil counts), globulin, amylase, and the BUN/creatinine ratio. Overall, the VC method was associated with the least variation in both sexes and appeared slightly better than the IC method for the parameters evaluated. The largest difference between groups was noted for the transaminase levels. While alanine aminotransferase (ALT) values were similar between the IC and VC groups, aspartate aminotransferase (AST) values were associated with less variation for the VC method. Transaminase levels for the MC and RO groups were associated with relatively large ranges and variation. ALT results from the RO method, the only method amenable to repetitive sample collection used in this evaluation, indicate that this is an acceptable method. The results demonstrate the substantial impact that phlebotomy method has on the assay results and that the VC or IC methods provide the most consistent results. The ranges by collection method and sex provided here can be used to select the preferred method of collection when designing a study and for comparison of data

  13. New approach to 'top-and-bottom' whole blood separation using the multiunit TACSI WB system: quality of blood components.

    Science.gov (United States)

    Lotens, A; Najdovski, T; Cellier, N; Ernotte, B; Lambermont, M; Rapaille, A

    2014-10-01

    TACSI whole blood system is designed to combine primary and secondary processing of six whole blood bags into plasma units, buffy coat and red blood cell concentrates. The aim of this study was to investigate the specifications and in vitro storage parameters of blood components compared with standard centrifugation and separation processing. Whole blood bags, collected in CRC kits, were treated on a TACSI whole blood system. They were compared with whole blood bags collected in Composelect kits. In addition to routine quality control analyses, conservation studies were performed on red blood cell concentrates for 42 days and on plasma for 6 months. Platelets pools with five buffy coats were also created, and cellular contamination was evaluated. Red blood cell concentrates produced from TACSI whole blood met European quality requirements. For white blood cell count, one individual result exceeded 1 × 10(6) cells/unit. All plasma units fell within specifications for residual cellular contamination and storage parameters. The performances of the TACSI whole blood system allow for the preparation of low volume buffy coats with a recovery of 90% of whole blood platelets. Haemoglobin losses in TACSI BC are smaller, but this did not result in higher haemoglobin content of red cells. These BC are suitable for the production of platelet concentrates. From these in vitro data, red blood cell concentrates produced using TACSI whole blood are suitable for clinical use with a quality at least equivalent to the control group. © 2014 International Society of Blood Transfusion.

  14. Pediatric blood sample collection from a pre-existing peripheral intravenous (PIV) catheter.

    Science.gov (United States)

    Braniff, Heather; DeCarlo, Ann; Haskamp, Amy Corey; Broome, Marion E

    2014-01-01

    Aiming to minimize pain in a hospitalized child, the purpose of this observational study was to describe characteristics of blood samples collected from pre-existing peripheral intravenous (PIV) catheters in pediatric patients. One hundred and fifty blood samples were reviewed for number of unusable samples requiring a specimen to be re-drawn. Success of the blood draw and prevalence of the loss of the PIV following blood collection was also measured. Findings included one clotted specimen, success rate of 91.3%, and 1.3% of PIVs becoming non-functional after collection. Obtaining blood specimens from a pre-existing PIV should be considered in a pediatric patient. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Platelet collection efficiencies of three different platelet-rich plasma preparation systems.

    Science.gov (United States)

    Aydin, Fatma; Pancar Yuksel, Esra; Albayrak, Davut

    2015-06-01

    Different systems have been used for the preparation of platelet-rich plasma (PRP), but platelet collection efficiencies of these systems are not clear. To evaluate the platelet collection efficiencies of three different PRP preparation systems. Blood samples were obtained from the same 16 volunteers for each system. The samples were centrifuged and PRP was prepared by three systems. The ratio of the total number of platelets in PRP to the total number of platelets of the venous blood sample of the patient expressed in percentage was named as platelet collection efficiency and calculated for each system. Mean platelet collection efficiencies were 66.6 (min: 56.9, max: 76.9), 58.3 (min: 27.3, max: 102.8), 50.8 (min: 27.2, max: 73) for top and bottom bag system, system using citrated tube, and the system using tube with Ficoll and cell extraction kit, respectively. Statistically significant difference was found only between the platelet collection efficiencies of systems using the tube with ficoll and cell extraction kit and the top and bottom bag system (p = 0.002). All three systems could be used for PRP preparation, but top and bottom bag system offers a slight advantage over the system using Ficoll and cell extraction kit regarding the platelet collection efficiency.

  16. Hypergravity-induced increase in plasma catecholamine and corticosterone levels in telemetrically collected blood of rats during centrifugation.

    Science.gov (United States)

    Petrak, Juraj; Mravec, Boris; Jurani, Marian; Baranovska, Magda; Tillinger, Andrej; Hapala, Ivan; Frollo, Ivan; Kvetnanský, Richard

    2008-12-01

    Rats subjected to various accelerations (+G) exhibited increased levels of plasma epinephrine (EPI), norepinephrine (NE), and corticosterone. However, the collection of blood was performed after a centrifugation finished, and therefore the levels could be affected by the process of deceleration. The aim of this study was to evaluate plasma EPI, NE, and corticosterone levels in blood collected directly during centrifugation after reaching different G (2-6), using newly developed remote-controlled equipment. Animals placed into the centrifuge cabins had inserted polyethylene tubing in the tail artery, which was connected with a preprogrammed device for blood withdrawals. Plasma EPI, NE, and corticosterone levels were measured at different time intervals of hypergravity of 2-6G. Plasma EPI levels showed a huge, hypergravity-level-dependent increase. After the last blood collection was completed during hypergravity, the centrifuge was turned off and another blood sampling was performed immediately after the centrifuge stopped (10 min). In these samples, plasma EPI showed significantly lower levels compared to centrifugation intervals. Plasma NE levels were significantly increased after 6G only. The increase in plasma corticosterone was dependent on level of G, however after the centrifuge stopped, corticosterone levels remained elevated. Thus, our data show that hypergravity highly activates the adrenomedullary and hypothalamo-pituitary-adrenocortical systems, whereas the sympathoneural system is activated only at high hypergravity. Immediately after centrifugation is over, EPI levels quickly return to control values. Our technique of blood collection during centrifugation allows assessment of the real hormonal levels at the particular hypergravity value.

  17. Evaluation of two different protocols for peripheral blood stem cell collection with the Fresenius AS 104 blood cell separator.

    Science.gov (United States)

    Menichella, G; Lai, M; Pierelli, L; Vittori, M; Serafini, R; Ciarli, M; Foddai, M L; Salerno, G; Sica, S; Scambia, G; Leone, G; Bizzi, B

    1997-01-01

    Reconstitution of hematopoiesis by means of peripheral blood stem cells is a valid alternative to autologous bone marrow transplantation. The aim of this investigation was to increase the efficiency of collection of circulating blood progenitor cells and to obtain a purer product for transplant. We carried out leukapheresis procedures with the Fresenius AS 104 blood cell separator, using two different protocols, the previously used PBSC-LYM and a new mononuclear cell collection program. Both programs were highly effective in collecting mononuclear cells (MNC) and CD34+ cells. Some differences were found, especially regarding MNC yield and efficiencies. There are remarkable differences in the efficiency of collection of CD34+ cells (62.38% with the new program as opposed to 31.69% with the older one). Linear regression analysis showed a negative correlation between blood volume processed and MNC efficiency only for the PBSC-LYM program. Differences were also observed in the degree of inverse correlation existing in both programs between patients' white blood cell precount and MNC collection efficiency. The inverse correlation was stronger for the PBSC-LYM program. Seven patients with solid tumors and hematologic malignancies received high dose chemotherapy and were subsequently transplanted with peripheral blood stem cells collected using the new protocol. All patients obtained a complete and stable engraftment with the reinfusion product collected with one or two leukapheresis procedures. High efficiencies and yields were observed in the new protocol for MNC and CD34+ cells. These were able to effect rapid and complete bone marrow recovery after myeloablative chemotherapy.

  18. Can a decentralized blood system ensure self-sufficiency and blood safety? The Lebanese experience.

    Science.gov (United States)

    Haddad, Antoine; Bou Assi, Tarek; Garraud, Olivier

    2017-08-01

    Lebanon has adopted a liberal economic system that also applies to healthcare procurement. There is no national Lebanese blood transfusion service and the blood supply is divided between a large number of licensed (45 per cent) and unlicensed (55 per cent) blood banks, many of them issuing a very limited number of blood components. All blood banks are hospital based and operate the entire transfusion chain, from collection to the release of blood units. Blood donation is voluntary and non-remunerated in 20-25 per cent of donations; it relies principally on replacement donations. Recently, Lebanon has faced political instability and war, and now welcomes an enormous number of refugees from neighboring countries at war. This has had an important impact on heath care and on the transfusion supply. We discuss the impact of the blood donation organization on the transfusion safety and ethics, to set the foundation for a more developed and safer transfusion programs.

  19. On the improvement of blood sample collection at clinical laboratories.

    Science.gov (United States)

    Grasas, Alex; Ramalhinho, Helena; Pessoa, Luciana S; Resende, Mauricio G C; Caballé, Imma; Barba, Nuria

    2014-01-09

    Blood samples are usually collected daily from different collection points, such hospitals and health centers, and transported to a core laboratory for testing. This paper presents a project to improve the collection routes of two of the largest clinical laboratories in Spain. These routes must be designed in a cost-efficient manner while satisfying two important constraints: (i) two-hour time windows between collection and delivery, and (ii) vehicle capacity. A heuristic method based on a genetic algorithm has been designed to solve the problem of blood sample collection. The user enters the following information for each collection point: postal address, average collecting time, and average demand (in thermal containers). After implementing the algorithm using C programming, this is run and, in few seconds, it obtains optimal (or near-optimal) collection routes that specify the collection sequence for each vehicle. Different scenarios using various types of vehicles have been considered. Unless new collection points are added or problem parameters are changed substantially, routes need to be designed only once. The two laboratories in this study previously planned routes manually for 43 and 74 collection points, respectively. These routes were covered by an external carrier company. With the implementation of this algorithm, the number of routes could be reduced from ten to seven in one laboratory and from twelve to nine in the other, which represents significant annual savings in transportation costs. The algorithm presented can be easily implemented in other laboratories that face this type of problem, and it is particularly interesting and useful as the number of collection points increases. The method designs blood collection routes with reduced costs that meet the time and capacity constraints of the problem.

  20. New aspects of blood collection and handling procedures for the assessment of t-PA and PAI-1 variables after the introduction of acid blood collection

    NARCIS (Netherlands)

    Meijer, P.; Kret, R.; Bloetjes, P.T.M.; Rosen, S.; Kluft, C.

    1994-01-01

    Blood collection and handling procedures for t-PA activity have thusfar been rather strict and have restrained the use in clinical practice. We evaluated simplifications in the procedures for specifically the use of Stabilyte® vacutainers with respect to time before centrifugation of blood, storage

  1. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members.

    Science.gov (United States)

    Närhi, M; Natri, O; Desbois, I; Kinggaard Holm, D; Galea, G; Aranko, K; Korhonen, M; Nordstrom, K

    2013-11-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization. An online questionnaire was used for data collection in 2011, and 43 replies were received covering 71 product answers from 13 countries. Estimated percentages of tissue and cell banking covered by EBA member blood banks as a proportion of all collections of each individual country varied markedly. There were also major differences in the amounts of products collected and discarded and in proportions tissues provided for grafting. However, discarding of certain collections also reflects the practice of increasing the likelihood of the very best units being used for transplantation. Harmonization of possible practices should focus on matching supply with demand and on identifying the most efficient operators. This could allow for the development of practices for minimizing unnecessary collections. © 2013 International Society of Blood Transfusion.

  2. Variability in blood and blood component utilization as assessed by an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Savage, Will J; Rothschild, Jim A; Rivers, Richard J; Ness, Paul M; Paul, Sharon L; Ulatowski, John A

    2012-07-01

    Data can be collected for various purposes with anesthesia information management systems. The authors describe methods for using data acquired from an anesthesia information management system to assess intraoperative utilization of blood and blood components. Over an 18-month period, data were collected on 48,086 surgical patients at a tertiary care academic medical center. All data were acquired with an automated anesthesia recordkeeping system. Detailed reports were generated for blood and blood component utilization according to surgical service and surgical procedure, and for individual surgeons and anesthesiologists. Transfusion hemoglobin trigger and target concentrations were compared among surgical services and procedures, and between individual medical providers. For all patients given erythrocytes, the mean transfusion hemoglobin trigger was 8.4 ± 1.5, and the target was 10.2 ± 1.5 g/dl. Variation was significant among surgical services (trigger range: 7.5 ± 1.2-9.5 ± 1.1, P = 0.0001; target range: 9.1 ± 1.2-11.3 ± 1.4 g/dl, P = 0.002), surgeons (trigger range: 7.2 ± 0.7-9.8 ± 1.0, P = 0.001; target range: 8.8 ± 0.9-11.8 ± 1.3 g/dl, P = 0.001), and anesthesiologists (trigger range: 7.2 ± 0.8-9.6 ± 1.2, P = 0.001; target range: 9.0 ± 0.9-11.7 ± 1.3 g/dl, P = 0.0004). The use of erythrocyte salvage, fresh frozen plasma, and platelets varied threefold to fourfold among individual surgeons compared with their peers performing the same surgical procedure. The use of data acquired from an anesthesia information management system allowed a detailed analysis of blood component utilization, which revealed significant variation among surgical services and surgical procedures, and among individual anesthesiologists and surgeons compared with their peers. Incorporating these methods of data acquisition and analysis into a blood management program could reduce unnecessary transfusions, an outcome that may increase patient safety and reduce costs.

  3. 21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Empty container for the collection and processing of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products...

  4. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    Science.gov (United States)

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of

  5. 21 CFR 864.6150 - Capillary blood collection tube.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Capillary blood collection tube. 864.6150 Section 864.6150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6150 Capillary...

  6. Volume-dependent hemodynamic effects of blood collection in canine donors - evaluation of 13% and 15% of total blood volume depletion

    Directory of Open Access Journals (Sweden)

    RUI R.F. FERREIRA

    2015-03-01

    Full Text Available Background: There is no consensus regarding the blood volume that could be safely donated by dogs, ranging from 11 to 25% of its total blood volume (TBV. No previous studies evaluated sedated donors.Aim: To evaluate the hemodynamic effects of blood collection from sedated and non-sedated dogs and to understand if such effects were volume-dependent.Materials and Methods: Fifty three donations of 13% of TBV and 20 donations of 15% TBV were performed in dogs sedated with diazepam and ketamine. Additionally, a total of 30 collections of 13% TBV and 20 collections of 15% TBV were performed in non-sedated dogs. Non-invasive arterial blood pressures and pulse rates were registered before and 15 min after donation. Results: Post-donation pulse rates increased significantly in both sedated groups, with higher differences in the 15% TBV collections. Systolic arterial pressures decreased significantly in these groups, while diastolic pressures increased significantly in 13% TBV donations. Non-sedated groups revealed a slight, but significant, SBP decrease. No clinical signs related to donations were registered.Conclusion: These results suggest that the collection of 15% TBV in sedated donors induces hemodynamic variations that may compromise the harmlessness of the procedure, while it seems to be a safe procedure in non-sedated dogs.

  7. Blood meal identification and feeding habits of uranotaenia species collected in the ryukyu archipelago.

    Science.gov (United States)

    Toma, Takako; Miyagi, Ichiro; Tamashiro, Mikako

    2014-09-01

    To know the blood meal in the stomach of Uranotaenia species, blood-fed mosquitoes were collected by 4 methods at different sites in the mountain forest of 3 islands, Amamioshima, Okinawajima, and Iriomotejima in the Ryukyu Archipelago, Japan from 2005 to 2012. One hundred twenty-four blood-fed Uranotaenia mosquitoes of 7 species (Ur. jacksoni, nivipleura, ohamai, yaeyamana, annandalei, lateralis, and macfarlanei) were collected. The collection rates are 0.26, 0.6, 0.31, and 0.66 by black light trap, black light blue with dry ice trap, frog call trap, and sweeping net, respectively. The blood meals of 107 females (86.3%) were successfully identified by a polymerase chain reaction-based method. All Uranotaenia species fed on cold-blooded animals, especially amphibians (99.1%), and notably on frogs. They would feed readily on available frogs in a given region having no close connection with the breeding (calling) season of each frog. They also fed on reptiles (0.9%), but not on warm-blooded animals.

  8. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    Science.gov (United States)

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  9. Chlamydia trachomatis antibody detection in home-collected blood samples for use in epidemiological studies.

    NARCIS (Netherlands)

    Hoenderboom, B M; van Ess, E F; van den Broek, I V F; van Loo, I H M; Hoebe, C J P A; Ouburg, S; Morré, S A

    Capillary blood collected in serum tubes was subjected to centrifugation delay while stored at room temperature. Chlamydia trachomatis (CT) IgG concentrations in aliquoted serum of these blood samples remained stable for seven days after collection. CT IgG concentrations can reliably be measured in

  10. A new strategy for umbilical cord blood collection developed at the first Colombian public cord blood bank increases total nucleated cell content.

    Science.gov (United States)

    Vanegas, Diana; Triviño, Lady; Galindo, Cristian; Franco, Leidy; Salguero, Gustavo; Camacho, Bernardo; Perdomo-Arciniegas, Ana-María

    2017-09-01

    The total nucleated cell dosage of umbilical cord blood (UCB) is an important factor in determining successful allogeneic hematopoietic stem cell transplantation after a minimum human leukocyte antigen donor-recipient match. The northern South American population is in need of a new-generation cord blood bank that cryopreserves only units with high total nucleated cell content, thereby increasing the likelihood of use. Colombia set up a public cord blood bank in 2014; and, as a result of its research for improving high total nucleated cell content, a new strategy for UCB collection was developed. Data from 2933 collected and 759 cryopreserved cord blood units between 2014 and 2015 were analyzed. The correlation of donor and collection variables with cellularity was evaluated. Moreover, blood volume, cell content, CD34+ count, clonogenic capacity, and microbial contamination were assessed comparing the new method, which combines in utero and ex utero techniques, with the conventional strategies. Multivariate analysis confirmed a correlation between neonatal birth weight and cell content. The new collection method increased total nucleated cell content in approximately 26% and did not alter pre-cryopreservation and post-thaw cell recovery, viability, or clonogenic ability. Furthermore, it showed a remarkably low microbial contamination rate (1.2%). The strategy for UCB collection developed at the first Colombian public cord blood bank increases total nucleated cell content and does not affect unit quality. The existence of this bank is a remarkable breakthrough for Latin-American patients in need of this kind of transplantation. © 2017 The Authors Transfusion published by Wiley Periodicals, Inc. on behalf of AABB.

  11. Remote blood collection in reindeer (Rangifer tarandus tarandus L: a preliminary study

    Directory of Open Access Journals (Sweden)

    E. Wiklund

    1994-12-01

    Full Text Available Automatic blood sampling equipment (ABSE was used successfully to collect blood samples from two reindeer. During blood sampling, two methods of restraint were applied which caused no short term changes in plasma concentrations of urea, aspartate aminotransferase, alanine aminotransferase or total protein. Plasma Cortisol concentrations were significantly elevated by the two restraint techniques. The value of ABSE in studies of stress in reindeer is discussed.

  12. 77 FR 10756 - Proposed Collection; Comment Request; Opinions and Perspectives About the Current Blood Donation...

    Science.gov (United States)

    2012-02-23

    ... with Men. Type of Information Collection Request: New. Need and Use of Information Collection: The... prevalence of compliance and non-compliance with the current MSM policy and assessing motivations for blood... donate blood. Frequency of Response: Once. Affected Public: Individuals. Type of Respondents: Males 18...

  13. Awareness of cord blood collection and the impact on banking.

    Science.gov (United States)

    Bhandari, Rusha; Lindley, Amy; Bhatla, Deepika; Babic, Aleksandar; Mueckl, Kathy; Rao, Rakesh; Brooks, Paula; Geiler, Vicki; Gross, Gilad; Al-Hosni, Mohamad; Shenoy, Shalini

    2017-07-01

    Umbilical cord blood (UCB) is an important source of hematopoietic stem cells for transplantation especially in minority populations with limited chances of finding a histocompatible volunteer donor in the registry. UCB has the advantages of early availability, successful outcomes despite some histocompatibility mismatch, and low incidence of chronic graft-versus-host disease. Public cord blood banks that disseminate UCB products for transplant depend on voluntary donation at participating hospitals and obstetrical providers for collection. Using survey questionnaires, we evaluated attitudes toward UCB donation, the frequency of donation, and provider opinions on UCB collection in the greater St. Louis metropolitan area that caters to minority ethnicities in significant numbers. Our data suggest that nervousness and lack of information regarding the donation and utility of the product were ubiquitous reasons for not donating. Additionally, irrespective of age or level of education, women relied on healthcare providers for information regarding UCB donation. Providers reported primarily time constraints to discussing UCB donation at prenatal visits (54%). Of the interviewees, 62% donated UCB. Fallout due to refusal or preferring private banking was miniscule. These results suggest that dedicated personnel focused on disseminating information, obtaining consent, and collecting the UCB product at major hospitals can enrich cord blood banks especially with minority cords. Sustained and focused efforts could improve upon a relatively high wastage rate and ensure a robust supply of UCB products at local public banks. © 2017 Wiley Periodicals, Inc.

  14. Evaluation of the antimicrobial removal device when used with the BACTEC blood culture system

    International Nuclear Information System (INIS)

    Strand, C.L.

    1982-01-01

    A study to determine the value of the Antimicrobial Removal Device (ARD) used in conjunction with radiometric detection of bacteremia using three media was conducted. During a 12-month period, 622 duplicate ARD/BACTEC blood-culture sets were collected. There were 88 positive cultures that yielded 68 pathogenic isolates and 28 probable contaminant isolates. When all patients were considered, 31 pathogenic isolates were detected by both systems, 25 pathogenic isolates were detected faster or only by the BACTEC system, and 12 pathogenic isolates were detected faster or only when the ARD was employed. This difference is statistically significant (P less than 0.05). Thus, the standard BACTEC blood-culture system using three different media was superior to the same BACTEC system using ARD-processed blood specimens. When only patients receiving antimicrobial therapy were considered, there were more pathogenic isolates detected from unprocessed blood than from blood processed in the ARD; however, this difference was not statistically significant. In conclusion, there appears to be no advantage to using the ARD system in conjunction with the three-bottle BACTEC blood-culture system

  15. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    Directory of Open Access Journals (Sweden)

    F. Majlessi

    2008-06-01

    Full Text Available The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sectional study was performed on 554 blood donors who had donated blood from February 2005 through September 2005 in four fixed blood donation bases and four mobile blood collection buses. Each base was considered as a stratum, and a stratified random sampling proportional to size was done to select the donors. Results showed donor reaction rate to be 13.4%, the most common of which were blackout of vision (7%, dizziness (6.3%, fatigue (6.1% and nausea (1.8%. There was no significant relationship between the incidence of these complications and type of base blood donation or fasting at the time of blood donation. Logistic Regression analysis showed that sex, condition of blood donor, exercise or walking, duration of donation, and practice to recommendation had significant effects on the odds ratio of systemic complication. Regarding the frequency values derived for the different systemic complications it can be concluded that attention to risk factors of these complications and their control can help encourage donors to become repeated donors as well as to prevent their withdrawal for further blood donation.

  16. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  17. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus.

    Science.gov (United States)

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E; Elkins, William; Nardone, Glenn A; Emerson, Suzanne U; Purcell, Robert H

    2007-06-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper discs from freshly killed deer. The discs were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of blood absorbed and were eluted and collected in one tube via a novel extraction system. The procedure was quantified and validated with negative and positive serum and blood samples obtained from domestic Sika deer before and after immunization with HEV recombinant capsid protein, respectively. None of the 155 tested samples contained antibody to HEV, suggesting that Sika deer in these populations, unlike those in Japan, do not pose a significant zoonotic threat for hepatitis E. However, the new method developed for collecting and eluting the samples should prove useful for field studies of many other pathogens.

  18. A new voluntary blood collection method for the Andean bear (Tremarctos ornatus) and Asiatic black bear (Ursus thibetanus).

    Science.gov (United States)

    Otaki, Yusuke; Kido, Nobuhide; Omiya, Tomoko; Ono, Kaori; Ueda, Miya; Azumano, Akinori; Tanaka, Sohei

    2015-01-01

    Various training methods have been developed for animal husbandry and health care in zoos and one of these trainings is blood collection. One training method, recently widely used for blood collection in Ursidae, requires setting up a sleeve outside the cage and gives access to limited blood collection sites. A new voluntary blood collection method without a sleeve was applied to the Andean bear (Tremarctos ornatus) and Asiatic black bear (Ursus thibetanus) with access to various veins at the same time. The present study evaluated the effectiveness of this new method and suggests improvements. Two Andean and two Asiatic black bears in Yokohama and Nogeyama Zoological Gardens, respectively, were trained to hold a bamboo pipe outside their cages. We could, thereby, simultaneously access superficial dorsal veins, the dorsal venous network of the hand, the cephalic vein from the carpal joint, and an area approximately 10 cm proximal to the carpal joint. This allowed us to evaluate which vein was most suitable for blood collection. We found that the cephalic vein, approximately 10 cm proximal to the carpal joint, was the most suitable for blood collection. This new method requires little or no modification of zoo facilities and provides a useful alternative method for blood collection. It could be adapted for use in other clinical examinations such as ultrasound examination. © 2015 Wiley Periodicals, Inc.

  19. Blood Collection from Local Abattoirs for Mass Production of Tsetse Flies to be used in the Sterile Insect Technique

    Energy Technology Data Exchange (ETDEWEB)

    Byamungu, M B; Kiimbisa, B; Matembo, S; Mashenga, G [Tsetse and Trypanosomiasis Research Institute, P.O. Box 1026, Tanga (Tanzania, United Republic of)

    2012-07-15

    The mass production of tsetse flies (Glossina spp.) for the sterile insect technique (SIT) requires a supply of quality blood. For some years already cattle blood has been used as food for laboratory reared flies. The blood is collected from an abattoir using standard procedures. The collection procedures, handling and storage require aseptic conditions to avoid contamination of the blood, which could be fatal to the flies. Fly mortality caused by low quality blood endangers the success of mass rearing. To rear healthy flies with good survival and production the blood should be of good quality - free of contamination and with a packed cell volume (PCV) above 25%. The present work involved the seasonal collection of blood from abattoirs in the United Republic of Tanzania (Tanga, Arusha, Dodoma, Dar-es-salaam). Dodoma was identified as having the best conditions for blood collection. To assess the quality of the blood as a diet for tsetse, blood was screened for the presence of bacteria, and the pathogens were identified. Protocols were developed for blood quality assurance. (author)

  20. Blood collection from the facial (maxillary)/musculo-cutaneous vein in true frogs (family Ranidae).

    Science.gov (United States)

    Forzán, María J; Vanderstichel, Raphaël V; Ogbuah, Christopher T; Barta, John R; Smith, Todd G

    2012-01-01

    Collection of blood from amphibians, as in other classes of vertebrate animals, is essential to evaluate parameters of health, diagnose hemoparasitism, identify viral and bacterial pathogens, and measure antibodies. Various methods of blood collection have been described for amphibians. Most can be cumbersome (venipucture of femoral vein, ventral abdominal vein or lingual venus plexus) or result in pain or deleterious health consequences (cardiac puncture and toe-clipping). We describe an easy and practical technique to collect blood from frogs and toads that can be used in multiple species and is minimally invasive. The technique consists of puncturing either the facial or, less commonly, the musculo-cutaneous vein and collecting the blood with a capillary tube. These veins run dorsal and parallel to the maxillary bone and can be accessed by quick insertion and withdrawal of a needle through the skin between the upper jawline and the rostral or caudal side of the tympanum. The needle should be of 27 or 30 gauge for anurans weighing more or less than 25 g, respectively. Although the technique has been used by some amphibian researchers for years, it is little known by others and has never been fully described in a peer-reviewed publication.

  1. Concordance of mutation detection in circulating tumor DNA in early clinical trials using different blood collection protocols

    DEFF Research Database (Denmark)

    Ahlborn, Lise B.; Madsen, Mette; Jonson, Lars

    2017-01-01

    in a clinical setting. Here we investigate the concordance between standard blood collection for molecular analysis using immediate separation of plasma, compared to the use of collection tubes allowing for delayed processing. Methods: In this study, we measured the fractional abundance of tumor specific...... patients with advanced solid cancers enrolled in early clinical trials. Results: Concordance in the fractional abundance of mutations in ctDNA isolated from blood collected in either K3EDTA or BCT tubes from patients with different solid cancers was observed. Conclusions: This study indicates that BCT...... mutations (BRAF p.V600E and PIK3CA p.H1047R) in ctDNA isolated from blood samples collected in either cell-stabilizing Cell-Free DNA BCT tubes (delayed processing within 72 hours) or standard K3EDTA tubes (immediate processing within 15 minutes). Twenty-five blood sample pairs (EDTA/BCT) were collected from...

  2. Progress in the blood supply of Afghanistan.

    Science.gov (United States)

    Riley, William J; McCullough, Terri Konstenius; Rhamani, Ahmad Masoud; McCullough, Jeffrey

    2017-07-01

    The blood supply system in Afghanistan was badly damaged by years of conflict. In 2009, the Afghanistan National Blood Safety and Transfusion Service (ANBSTS) was established. For 6 years, we collaborated to assist with policy and infrastructure development; blood bank operations; blood collection, testing, and component production; transfusion practices; and training of technicians, nurses, midwives, and physicians. Policies were established, infrastructure was strengthened, and capable staff was acquired and trained. Standard operating procedures were developed, testing was improved, and quality systems were established. Thirty trainings were held for blood center staff. Four additional formal trainings were held for 39 physicians, 36 nurses and/or midwives, and 38 laboratory technicians. During 5 years of this project, blood collection increased by 40%. The ANBSTS has made impressive progress developing infrastructure, personnel, procedures, quality systems, and training programs and increasing blood collection. Knowledge of transfusion medicine was improved through structured training. © 2017 AABB.

  3. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgene Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray.

    Science.gov (United States)

    Kennedy, Laura; Vass, J Keith; Haggart, D Ross; Moore, Steve; Burczynski, Michael E; Crowther, Dan; Miele, Gino

    2008-08-25

    Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene() RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2() enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene() blood samples also advocate a short, fixed room temperature storage time for all PAXgene() blood samples collected for the purposes of global transcriptional profiling in clinical studies.

  4. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgene™ Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray

    Science.gov (United States)

    Kennedy, Laura; Vass, J. Keith; Haggart, D. Ross; Moore, Steve; Burczynski, Michael E.; Crowther, Dan; Miele, Gino

    2008-01-01

    Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgene™ RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2™ enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgene™ blood samples also advocate a short, fixed room temperature storage time for all PAXgene™ blood samples collected for the purposes of global transcriptional profiling in clinical studies. PMID:19578521

  5. Use of self-collected capillary blood samples for islet autoantibody screening in relatives: a feasibility and acceptability study.

    Science.gov (United States)

    Liu, Y; Rafkin, L E; Matheson, D; Henderson, C; Boulware, D; Besser, R E J; Ferrara, C; Yu, L; Steck, A K; Bingley, P J

    2017-07-01

    To evaluate the feasibility of using self-collected capillary blood samples for islet autoantibody testing to identify risk in relatives of people with Type 1 diabetes. Participants were recruited via the observational TrialNet Pathway to Prevention study, which screens and monitors relatives of people with Type 1 diabetes for islet autoantibodies. Relatives were sent kits for capillary blood collection, with written instructions, an online instructional video link and a questionnaire. Sera from capillary blood samples were tested for autoantibodies to glutamic acid decarboxylase, islet antigen-2, insulin and zinc transporter 8. 'Successful' sample collection was defined as obtaining sufficient volume and quality to provide definitive autoantibody results, including confirmation of positive results by repeat assay. In 240 relatives who returned samples, the median (range) age was 15.5 (1-49) years and 51% were male. Of these samples, 98% were sufficient for glutamic acid decarboxylase, islet antigen-2 and zinc transporter 8 autoantibody testing and 84% for insulin autoantibody testing and complete autoantibody screen. The upper 90% confidence bound for unsuccessful collection was 4.4% for glutamic acid decarboxylase, islet antigen-2 and/or zinc transporter 8 autoantibody assays, and 19.3% for insulin autoantibodies. Despite 43% of 220 questionnaire respondents finding capillary blood collection uncomfortable or painful, 82% preferred home self-collection of capillary blood samples compared with outpatient venepuncture (90% of those aged 18 years). The perceived difficulty of collecting capillary blood samples did not affect success rate. Self-collected capillary blood sampling offers a feasible alternative to venous sampling, with the potential to facilitate autoantibody screening for Type 1 diabetes risk. © 2017 Diabetes UK.

  6. The circulatory system: blood procurement, AIDS, and the social body in China.

    Science.gov (United States)

    Erwin, Kathleen

    2006-06-01

    The market for blood thrived in China for more than a decade, preying on rural villagers desperate for cash. Profit motives and unhygienic collection created an AIDS epidemic, where now up to 80 percent of adults in some villages are HIV infected. Today, illegal blood banks continue to operate in some areas. Moreover, better screening and blood testing do little to address the underlying cultural reluctance to give blood. This article examines what is at stake for blood donors in the circulation of blood through both the physical and the social bodies in China today. I argue that public health and social policy solutions require consideration of the symbolic meanings of blood and the body, kin relations, and gift exchange. China's HIV-contaminated blood procurement crisis demands a critical reexamination of the hidden processes embedded in a "circulatory system" that has inseparably bound the "gift of life" and a "commodity of death".

  7. Effects of Storage and Type of Blood Collection Tubes on Hepatitis C Virus Level in Whole Blood Samples

    Science.gov (United States)

    Kessler, Harald H.; Stelzl, Evelyn; Raggam, Reinhard B.; Haas, Josef; Kirchmeir, Franz; Hegenbarth, Karin; Daghofer, Elisabeth; Santner, Brigitte I.; Marth, Egon; Stauber, Rudolf E.

    2001-01-01

    In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at “date zero.” In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport. PMID:11325991

  8. Hematopoietic Lineage Transcriptome Stability and Representation in PAXgeneTM Collected Peripheral Blood Utilising SPIA Single-Stranded cDNA Probes for Microarray

    Directory of Open Access Journals (Sweden)

    Laura Kennedy

    2008-01-01

    Full Text Available Peripheral blood as a surrogate tissue for transcriptome profiling holds great promise for the discovery of diagnostic and prognostic disease biomarkers, particularly when target tissues of disease are not readily available. To maximize the reliability of gene expression data generated from clinical blood samples, both the sample collection and the microarray probe generation methods should be optimized to provide stabilized, reproducible and representative gene expression profiles faithfully representing the transcriptional profiles of the constituent blood cell types present in the circulation. Given the increasing innovation in this field in recent years, we investigated a combination of methodological advances in both RNA stabilisation and microarray probe generation with the goal of achieving robust, reliable and representative transcriptional profiles from whole blood. To assess the whole blood profiles, the transcriptomes of purified blood cell types were measured and compared with the global transcriptomes measured in whole blood. The results demonstrate that a combination of PAXgeneTM RNA stabilising technology and single-stranded cDNA probe generation afforded by the NuGEN Ovation RNA amplification system V2TM enables an approach that yields faithful representation of specific hematopoietic cell lineage transcriptomes in whole blood without the necessity for prior sample fractionation, cell enrichment or globin reduction. Storage stability assessments of the PAXgeneTM blood samples also advocate a short, fixed room temperature storage time for all PAXgeneTM blood samples collected for the purposes of global transcriptional profiling in clinical studies.

  9. The Blood Stocks Management Scheme, a partnership venture between the National Blood Service of England and North Wales and participating hospitals for maximizing blood supply chain management.

    Science.gov (United States)

    Chapman, J F; Cook, R

    2002-10-01

    The Blood Stocks Management Scheme (BSMS) has been established as a joint venture between the National Blood Service (NBS) in England and North Wales and participating hospitals to monitor the blood supply chain. Stock and wastage data are submitted to a web-based data-management system, facilitating continuous and complete red cell data collection and 'real time' data extraction. The data-management system enables peer review of performance in respect of stock holding levels and red cell wastage. The BSMS has developed an innovative web-based data-management system that enables data collection and benchmarking of practice, which should drive changes in stock management practice, therefore optimizing the use of donated blood.

  10. 21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood gases (PCO2, PO2) and blood pH test system... Test Systems § 862.1120 Blood gases (PCO2, PO2) and blood pH test system. (a) Identification. A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum...

  11. Good practices in collecting umbilical cord and placental blood.

    Science.gov (United States)

    Lopes, Lauren Auer; Bernardino, Elizabeth; Crozeta, Karla; Guimarães, Paulo Ricardo Bittencourt

    2016-08-18

    to identify the factors related to the quality of umbilical cord and placental blood specimens, and define best practices for their collection in a government bank of umbilical cord and placental blood. this was a descriptive study, quantitative approach, performed at a government umbilical cord and placental blood bank, in two steps: 1) verification of the obstetric, neonatal and operational factors, using a specific tool for gathering data as non-participant observers; 2) definition of best practices by grouping non-conformities observed before, during and after blood collection. The data was analyzed using descriptive statistics and the following statistical software: Statistica(r) and R(r). while there was a correlation with obstetrical and neonatal factors, there was a larger correlation with operational factors, resulting in the need to adjust the professional practices of the nursing staff and obstetrical team involved in collecting this type of blood. Based on these non-conformities we defined best practices for nurses before, during and after blood collection. the best practices defined in this study are an important management tool for the work of nurses in obtaining blood specimens of high cell quality. identificar fatores relacionados à qualidade das amostras do sangue de cordão umbilical e placentário e definir boas práticas para sua coleta em um banco público de sangue de cordão umbilical e placentário. pesquisa descritiva, abordagem quantitativa, realizada em um banco público de sangue de cordão umbilical e placentário, desenvolvida em duas etapas: 1) verificação dos fatores obstétricos, neonatais e operacionais, obtidos por coleta em instrumento próprio e observação não participante; 2) definição das boas práticas, por meio do agrupamento de não-conformidades observadas antes, durante e após a coleta do sangue. Os dados foram analisados por meio da estatística descritiva, utilizando-se dos softwares Statistica(r) e R(r). houve

  12. Impact of partial pressure of oxygen in blood samples on the performance of systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Schmid, Christina; Baumstark, Annette; Pleus, Stefan; Haug, Cornelia; Tesar, Martina; Freckmann, Guido

    2014-03-01

    The partial pressure of oxygen (pO2) in blood samples can affect glucose measurements with oxygen-sensitive systems. In this study, we assessed the influence of different pO2 levels on blood glucose (BG) measurements with five glucose oxidase (GOD) systems and one glucose dehydrogenase (GDH) system. All selected GOD systems were indicated by the manufacturers to be sensitive to increased oxygen content of the blood sample. Venous blood samples of 16 subjects (eight women, eight men; mean age, 52 years; three with type 1 diabetes, four with type 2 diabetes, and nine without diabetes) were collected. Aliquots of each sample were adjusted to the following pO2 values: ≤45 mm Hg, approximately 70 mm Hg, and ≥150 mm Hg. For each system, five consecutive measurements on each sample were performed using the same test strip lot. Relative differences between the mean BG value at a pO2 level of approximately 70 mm Hg, which was considered to be similar to pO2 values in capillary blood samples, and the mean BG value at pO2 levels ≤45 mm Hg and ≥150 mm Hg were calculated. The GOD systems showed mean relative differences between 11.8% and 44.5% at pO2 values ≤45 mm Hg and between -14.6% and -21.2% at pO2 values ≥150 mm Hg. For the GDH system, the mean relative differences were -0.3% and -0.2% at pO2 values ≤45 mm Hg and ≥150 mm Hg, respectively. The magnitude of the pO2 impact on BG measurements seems to vary among the tested oxygen-sensitive GOD systems. The pO2 range in which oxygen-sensitive systems operate well should be provided in the product information.

  13. Retrospective evaluation of unexpected events during collection of blood donations performed with and without sedation in cats (2010-2013).

    Science.gov (United States)

    Doolin, Kerry S; Chan, Daniel L; Adamantos, Sophie; Humm, Karen

    2017-09-01

    Describe unexpected events (UEs) that occurred during blood donation in cats with and without sedation. Retrospective observational study (2010-2013). University teaching hospital. Client-owned healthy cats enrolled in a blood donation program. None. Blood collection for transfusion was performed 115 times from 32 cats. Seventy donation events were in unsedated cats and 45 in sedated cats. For each collection, the anticipated blood volume to be collected, actual blood volume collected, sedation protocol, and any UE in the peridonation period were recorded. There were 6 categories of UEs: movement during donation, donor anxiety, inadequate collected blood volume, jugular vessel related UEs, additional sedation requirement, and cardiorespiratory distress. Fisher's exact test was used to compare the frequency of UEs between sedated and unsedated cats. UEs were recorded in 54 of 115 collections. In the donor population, movement was reported as an UE in 0 cats that donated under sedation and 24/70 (34.3%) cats that donated without sedation (P donated under sedation and 14/70 (20.0%) cats that donated unsedated (P = 0.014). Unsedated donation did not increase the likelihood of inadequate donation volume, jugular vessel related UEs, or cardiorespiratory distress. Eight of 45 (17.8%) sedated donations required additional sedation. Movement during donation and signs of donor anxiety were more frequent in unsedated cats. These were considered minor issues, expected in unsedated cats being gently restrained. Blood collection from unsedated feline donors is a viable alternative to sedated donation. © Veterinary Emergency and Critical Care Society 2017.

  14. Quality indicators for discarding blood in the National Blood Center, Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Mohammed Morish

    2012-01-01

    Full Text Available Background and Objective: The implementation of quality system and continuous evaluation of all activities of the Blood Transfusion Services (BTS can help to achieve the maximum quantity and quality of safe blood. Optimizing blood collection and processing would reduce the rate of discard and improve the efficiency of the BTS. The objective of this study is to determine the rate of discard of blood and blood component and identify its reasons at the National Blood Centre (NBC, Kuala Lumpur, during the year of 2007 in order to introduce appropriate intervention. Study Designs and Methods: Data on the number of discarded whole blood units and its components, reasons for discard, and the number of blood components processed as well as the number of collected blood units were obtained from the Blood Bank Information System - NBC database. These were analyzed. Results: The total number of blood units collected in 2007 was 171169 from which 390636 units of components were prepared. The total number of discarded whole blood units and its components was 8968 (2.3%. Platelet concentrate recorded the highest of discard at 6% (3909 followed by whole blood at 3.7% (647, fresh frozen plasma (FFP at 2.5% (2839, and cryoprecipitate at 2% (620. The rate of discarded packed red blood cells RBCs, plasma aphaeresis, and PLT aphaeresis was less than 1% at 0.6% (902, 0.6% (37, and 0.29% (14, respectively. RBC contamination of PLT and plasma were the major cause of discard at 40% (3558. Other causes include leakage (26% - 2306, lipemia (25% - 2208, and underweight (4% - 353. Conclusion: Good donor selection, training and evaluation of the staff, as well as implementation of automation will help to improve processes and output of BTS. This would reduce discard of blood components and wastage caused by non conformance.

  15. Blood and Blood Components: From Similarities to Differences

    Directory of Open Access Journals (Sweden)

    Olivier Garraud

    2018-04-01

    Full Text Available Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025, many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations of blood transfusion diversity and the consequences for donors, patients, and society.

  16. Blood and Blood Components: From Similarities to Differences

    Science.gov (United States)

    Garraud, Olivier; Tissot, Jean-Daniel

    2018-01-01

    Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation) either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025), many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations) of blood transfusion diversity and the consequences for donors, patients, and society. PMID:29686986

  17. A Rational Framework for Production Decision Making in Blood Establishments

    Directory of Open Access Journals (Sweden)

    Ramoa Augusto

    2012-12-01

    Full Text Available SAD_BaSe is a blood bank data analysis software, created to assist in the management of blood donations and the blood production chain in blood establishments. In particular, the system keeps track of several collection and production indicators, enables the definition of collection and production strategies, and the measurement of quality indicators required by the Quality Management System regulating the general operation of blood establishments.

  18. Blood groups and human groups: collecting and calibrating genetic data after World War Two.

    Science.gov (United States)

    Bangham, Jenny

    2014-09-01

    Arthur Mourant's The Distribution of the Human Blood Groups (1954) was an "indispensable" reference book on the "anthropology of blood groups" containing a vast collection of human genetic data. It was based on the results of blood-grouping tests carried out on half-a-million people and drew together studies on diverse populations around the world: from rural communities, to religious exiles, to volunteer transfusion donors. This paper pieces together sequential stages in the production of a small fraction of the blood-group data in Mourant's book, to examine how he and his colleagues made genetic data from people. Using sources from several collecting projects, I follow how blood was encountered, how it was inscribed, and how it was turned into a laboratory resource. I trace Mourant's analytical and representational strategies to make blood groups both credibly 'genetic' and understood as relevant to human ancestry, race and history. In this story, 'populations' were not simply given, but were produced through public health, colonial and post-colonial institutions, and by the labour and expertise of subjects, assistants and mediators. Genetic data were not self-evidently 'biological', but were shaped by existing historical and geographical identities, by political relationships, and by notions of kinship and belonging. Copyright © 2014 The Author. Published by Elsevier Ltd.. All rights reserved.

  19. Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies

    Science.gov (United States)

    Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.

    2014-01-01

    Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728

  20. Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.

    Science.gov (United States)

    Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong

    2018-01-01

    With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.

  1. Peripheral blood CD34+ cell count as a predictor of adequacy of hematopoietic stem cell collection for autologous transplantation

    Directory of Open Access Journals (Sweden)

    Combariza, Juan F.

    2016-10-01

    Full Text Available Introduction: In order to carry out an autologous transplantation, hematopoietic stem cells should be mobilized to peripheral blood and later collected by apheresis. The CD34+ cell count is a tool to establish the optimal time to begin the apheresis procedure. Objective: To evaluate the association between peripheral blood CD34+ cell count and the successful collection of hematopoietic stem cells. Materials and methods: A predictive test evaluation study was carried out to establish the usefulness of peripheral blood CD34+ cell count as a predictor of successful stem cell collection in patients that will receive an autologous transplantation. Results: 77 patients were included (median age: 49 years; range: 5-66. The predominant baseline diagnosis was lymphoma (53.2 %. The percentage of patients with successful harvest of hematopoietic stem cells was proportional to the number of CD34+cells in peripheral blood at the end of the mobilization procedure. We propose that more than 15 CD34+cells/μL must be present in order to achieve an adequate collection of hematopoietic stem cells. Conclusion: Peripheral blood CD34+ cell count is a useful tool to predict the successful collection of hematopoietic stem cells.

  2. 77 FR 35408 - Proposed Collection; Comment Request: Opinions and Perspectives About the Current Blood Donation...

    Science.gov (United States)

    2012-06-13

    ... Policy for Men Who Have Sex with Men. Type of Information Collection Request: New. Need and Use of... prevalence of compliance and non-compliance with the current MSM policy and assessing motivations for blood... donate blood. Frequency of Response: Once. Affected Public: Individuals. Type of Respondents: Males 18...

  3. Blood-brain barrier-on-a-chip: Microphysiological systems that capture the complexity of the blood-central nervous system interface.

    Science.gov (United States)

    Phan, Duc Tt; Bender, R Hugh F; Andrejecsk, Jillian W; Sobrino, Agua; Hachey, Stephanie J; George, Steven C; Hughes, Christopher Cw

    2017-11-01

    The blood-brain barrier is a dynamic and highly organized structure that strictly regulates the molecules allowed to cross the brain vasculature into the central nervous system. The blood-brain barrier pathology has been associated with a number of central nervous system diseases, including vascular malformations, stroke/vascular dementia, Alzheimer's disease, multiple sclerosis, and various neurological tumors including glioblastoma multiforme. There is a compelling need for representative models of this critical interface. Current research relies heavily on animal models (mostly mice) or on two-dimensional (2D) in vitro models, neither of which fully capture the complexities of the human blood-brain barrier. Physiological differences between humans and mice make translation to the clinic problematic, while monolayer cultures cannot capture the inherently three-dimensional (3D) nature of the blood-brain barrier, which includes close association of the abluminal side of the endothelium with astrocyte foot-processes and pericytes. Here we discuss the central nervous system diseases associated with blood-brain barrier pathology, recent advances in the development of novel 3D blood-brain barrier -on-a-chip systems that better mimic the physiological complexity and structure of human blood-brain barrier, and provide an outlook on how these blood-brain barrier-on-a-chip systems can be used for central nervous system disease modeling. Impact statement The field of microphysiological systems is rapidly evolving as new technologies are introduced and our understanding of organ physiology develops. In this review, we focus on Blood-Brain Barrier (BBB) models, with a particular emphasis on how they relate to neurological disorders such as Alzheimer's disease, multiple sclerosis, stroke, cancer, and vascular malformations. We emphasize the importance of capturing the three-dimensional nature of the brain and the unique architecture of the BBB - something that until recently

  4. Intelligent micro blood typing system using a fuzzy algorithm

    International Nuclear Information System (INIS)

    Kang, Taeyun; Cho, Dong-Woo; Lee, Seung-Jae; Kim, Yonggoo; Lee, Gyoo-Whung

    2010-01-01

    ABO typing is the first analysis performed on blood when it is tested for transfusion purposes. The automated machines used in hospitals for this purpose are typically very large and the process is complicated. In this paper, we present a new micro blood typing system that is an improved version of our previous system (Kang et al 2004 Trans. ASME, J. Manuf. Sci. Eng. 126 766, Lee et al 2005 Sensors Mater. 17 113). This system, fabricated using microstereolithography, has a passive valve for controlling the flow of blood and antibodies. The intelligent micro blood typing system has two parts: a single-line micro blood typing device and a fuzzy expert system for grading the strength of agglutination. The passive valve in the single-line micro blood typing device makes the blood stop at the entrance of a micro mixer and lets it flow again after the blood encounters antibodies. Blood and antibodies are mixed in the micro mixer and agglutination occurs in the chamber. The fuzzy expert system then determines the degree of agglutination from images of the agglutinated blood. Blood typing experiments using this device were successful, and the fuzzy expert system produces a grading decision comparable to that produced by an expert conducting a manual analysis

  5. Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

    Science.gov (United States)

    Murray, P R

    1991-01-01

    Although the detection of fungemia has been improved by the use of vented or biphasic blood culture bottles, the best recovery and earliest detection have been reported in the Isolator lysis-centrifugation system. It was recently demonstrated that improved detection of both bacteria and fungi was accomplished by mechanically agitating blood culture bottles for the first 24 h of incubation. In this study the detection of fungemia by use of the Isolator system was compared with that of an agitated biphasic system. A total of 182 fungi were isolated from blood specimens inoculated into both culture systems. No difference in the overall recovery of fungi or individual species of yeasts was observed between the two systems. However, all seven isolates of Histoplasma capsulatum were recovered in the Isolator system only. The time required to detect fungemia with each of the two systems was also compared. No statistically significant difference was observed. From the data collected during this 18-month study, it can be concluded that the overall recovery and time of detection of yeasts are equivalent in the lysis-centrifugation system and the agitated biphasic blood culture system. The lysis-centrifugation system is still superior for the detection of filamentous fungi such as H. capsulatum. PMID:1993772

  6. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    Science.gov (United States)

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  7. The impact of preapheresis white blood cell count on autologous peripheral blood stem cell collection efficiency and HSC infusion side effect rate.

    Science.gov (United States)

    Sakashita, Araci M; Kondo, Andrea T; Yokoyama, Ana Paula H; Lira, Sanny M C; Bub, Carolina B; Souza, Aline M; Cipolletta, Andrea N F; Alvarez, Kelen C; Hamerschlak, Nelson; Kutner, Jose M; Chiattone, Carlos S

    2018-01-19

    Autologous peripheral blood hematopoietic stem cell (PBSC) collection efficiency (CE) is reportedly affected by the patient's blood properties; however, studies to identify factors correlated with CE have shown inconsistent results. Additionally, variables such as stem cell graft granulocyte content and patient age, sex, and underlying disease, may be associated with hematopietic stem cell (HSC) infusion-related adverse reactions. In this study, we evaluated the correlation of preleukapheresis PB granulocyte count and PBSC harvest variables with CD34 + collection yield and efficiency, and thawed HSC infusion side effect occurrence. We evaluated data from 361 patients who had undergone autologous PBSC transplant. Large volume leukapheresis was the method for PBSC collection. Complete Blood Count and CD34 + cell enumeration were performed in the preapheresis PB and the apheresis product sample. The PBSC grafts were submitted to non-controlled rate freezing after addition of 5% DMSO plus 6% hidroxyethylstarch as a cryoprotectant solution. The cryopreserved graft was thawed in a 37°C water bath and then infused without further manipulation. The CD34 + yield was associated with preapheresis PB CD34 + count and immature granulocyte count. The PBSC CE was negatively correlated with preapheresis white blood cell (WBC), immature granulocyte and granulocyte count. The leukapheresis product total nucleated cell (TNC) and granulocyte content was correlated with the thawed graft infusion side effect occurrence. This study has shown that preapheresis PB WBC and granulocyte counts were associated with leukapheresis CE. Additionally, the leukapheresis product TNC and granulocyte content was correlated with thawed graft infusion side effect occurrence. © 2018 Wiley Periodicals, Inc.

  8. [Comparison of the determination of cyclosporin-A in blood samples collected on filter paper and by the ordinary technique].

    Science.gov (United States)

    Azevedo, L S; Manrique, R; Sabbaga, E

    1995-01-01

    Monitoring cyclosporin-A (CsA) blood levels is of utmost importance for the rational use of this drug. Although many centers perform transplants, in Brazil there are few laboratories able to measure CsA blood levels. Therefore making blood samples reach the laboratory emerged as a problem. Collection of blood on filter paper has been a technique used for a long time in special cases. PURPOSE--To confirm the usefulness of measuring CsA blood levels in blood samples collected on filter paper and in the usual way. METHOD--We studied twenty renal cadaver kidney recipients who were receiving CsA, azathioprine and prednisone. Ninety five blood samples were collected and divided into two aliquots. One of them was sent routinely to one laboratory to perform whole blood CsA measurements. From the other aliquot, 20 microliters were pipetted on filter paper. When dried they were mailed to the other laboratory, where, after elution, CsA was measured. In both cases radioimmunoassay with polyclonal antibody was used. RESULTS--Linear correlation between both measurements revealed r = 0.81 with no statistical difference. CONCLUSION--The technique showed to be useful in clinical practice. In countries with continental size, as Brazil, it may be very helpful.

  9. Nocturnal variations in peripheral blood flow, systemic blood pressure, and heart rate in humans

    DEFF Research Database (Denmark)

    Sindrup, J H; Kastrup, J; Christensen, H

    1991-01-01

    Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage uni.......0001). The synchronism of the nocturnal subcutaneous hyperemia and the decrease in systemic mean arterial blood pressure point to a common, possibly central nervous or humoral, eliciting mechanism.......Subcutaneous adipose tissue blood flow rate, together with systemic arterial blood pressure and heart rate under ambulatory conditions, was measured in the lower legs of 15 normal human subjects for 12-20 h. The 133Xe-washout technique, portable CdTe(Cl) detectors, and a portable data storage unit...

  10. Improving the blood supply chain: simulation and optimisation models to support collection, production and location-allocation decisions

    OpenAIRE

    Osorio Muriel, Andres

    2016-01-01

    This thesis introduces and studies different problems in the blood supply chain. The problems are focused on aspects less frequently studied in the literature such as the exploitation of the different collection and production alternatives, consideration of multiple products and uncertainty in demand and supply. These important features can be found in different decision levels, including daily collections, annual planning and at the strategic level when the blood supply chain is designed. Fo...

  11. 76 FR 82300 - Agency Information Collection Activities; Proposed Collection; Comment Request; Revisions to...

    Science.gov (United States)

    2011-12-30

    ... Requirements for Blood and Blood Components, Including Source Plasma AGENCY: Food and Drug Administration, HHS..., including Source Plasma. These requirements will facilitate the use of a labeling system using machine.... DATES: Submit either electronic or written comments on the collection of information by February 28...

  12. The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine.

    Science.gov (United States)

    Elliott, Paul; Peakman, Tim C

    2008-04-01

    UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is

  13. Plasma fractionation, a useful means to improve national transfusion system and blood safety: Iran experience.

    Science.gov (United States)

    Cheraghali, A M; Abolghasemi, H

    2009-03-01

    In 1974, the government of Iran established Iranian Blood Transfusion Organization (IBTO) as national and centralized transfusion system. Since then donations of blood may not be remunerated and therapy with blood and its components are free of charges for all Iranian patients. Donations are meticulously screened through interviewing donors and lab testing the donations using serological methods. Currently, Iranian donors donate 1735 00 units of blood annually (donation index: 25/1000 population). Implementation of a highly efficient donor selection programme, including donors interview, establishment of confidential unit exclusion programme and laboratory screening of donated bloods by IBTO have led to seroprevalence rates of 0.41%, 0.12% and 0.004% for HBV, HCV and HIV in donated bloods respectively. Since 2004, IBTO has initiated a programme to enter into a contract fractionation agreement for the surplus of recovered plasma produced in its blood collecting centres. Although IBTO has used this project as a mean to improve national transfusion system through upgrading its quality assurance systems, IBTO fractionation project has played a major role in improving availability of plasma-derived medicines in Iran. During 2006-2007, this project furnished the Iran market with 44% and 14% of its needs to the intravenous immunoglobulin and albumin, respectively. Iranian experience showed that contract fractionation of plasma in countries with organized centralized transfusion system, which lack national plasma fractionation facility, in addition to substantial saving on national health resource and enhancing availability of plasma-derived medicines, could serve as a useful means to improve national blood safety profile.

  14. Anti-phenolic glycolipid-I (PGL-I determination using blood collection on filter paper in leprosy patients

    Directory of Open Access Journals (Sweden)

    TOMIMORI-YAMASHITA Jane

    1999-01-01

    Full Text Available The authors studied 70 leprosy patients and 20 normal individuals, comparing the traditional sera collection method and the finger prick blood with the conservation on filter paper for specific antibodies against the native phenolic glycolipid-I (PGL-I from Mycobacterium leprae. The finger prick blood dried on filter paper was eluated in phosphate buffer saline (PBS containing 0.5% gelatin. The classical method for native PGL-I was performed for these eluates, and compared with the antibody determination for sera. It was observed that there is a straight correlation comparing these two methods; although the titles found for the eluates were lower than those obtained for serology. This blood collection method could be useful for investigation of new leprosy cases in field, specially in contacts individuals.

  15. Levels of persistent fluorinated, chlorinated and brominated compounds in human blood collected in Sweden in 1997-2000

    Energy Technology Data Exchange (ETDEWEB)

    Lindstroem, G.; Kaerrman, A.; Bavel, B. van [MTM Research Centre, Oerebro Univ. (Sweden); Hardell, L. [Dept. of Oncology, Univ. Hospital, Oerebro (Sweden); Hedlund, B. [Environmental Monitoring Section, Swedish EPA, Stockholm (Sweden)

    2004-09-15

    Levels of persistent fluorinated, chlorinated and brominated compounds in blood collected from the Swedish population have been determined in connection with several exposure and monitoring studies at the MTM Research Centre. A data base with 631 individual congener specific measurements on halogenated POPs such as dioxins, PCBs, HCB, DDE, chlordanes, PBDEs and PFAs including information on residency, age, BMI, diet, occupation, number of children, smoking habits, immunological status etc. has been compiled from samples collected between 1994 and 2004. A brief overview focusing on levels of some persistent chlorinated, brominated and fluorinated, compounds in blood collected in a background population group (n=83) in 1997-2000 is given here.

  16. Theorical and practical bases for blood sample collection from the heel of newborns for neonatal screening

    Directory of Open Access Journals (Sweden)

    Marcela Vela-Amieva

    2014-07-01

    collected in a special filter paper (Guthrie’s card. Despite its apparent simplicity, NBS laboratories commonly receive a large number of samples collected incorrectly and technically unsuitable for perfor4ming biochemical determinations. The aim of the present paper is to offer recommendations based on scientific evidence, for the properly blood collection on filter paper for NBS programs.

  17. Thixotropic gel-like composition and sterile blood-collecting and separating device

    International Nuclear Information System (INIS)

    Semersky, F.E.

    1980-01-01

    A thixotropic gel-like composition comprising liquid polybutadiene and an inorganic inert filler dispersed therein is adapted for use as a sealing barrier between separated phases of differing densities of a fluid in which said composition has at rest a density intermediate said differing densities, said gel-like composition being substantially resistant to sterilizing radiation. There is also disclosed a pre-packaged blood collecting and separating device which contains a mixture of liquid polybutadiene and an inorganic, inert filler, such as silica, as a thixotropic gel adapted at rest to form a sealing barrier between separated blood phases. The device and gel are subjected to sterilizing radiation to form a substantially sterile device, substantially free of backflow contamination without degradation of the physical properties of the gel. (author)

  18. Namibia's transition from whole blood-derived pooled platelets to single-donor apheresis platelet collections

    NARCIS (Netherlands)

    Pitman, John P.; Basavaraju, Sridhar V.; Shiraishi, Ray W.; Wilkinson, Robert; von Finckenstein, Bjorn; Lowrance, David W.; Marfin, Anthony A.; Postma, Maarten; Mataranyika, Mary; Smit Sibinga, Cees Th.

    BACKGROUNDFew African countries separate blood donations into components; however, demand for platelets (PLTs) is increasing as regional capacity to treat causes of thrombocytopenia, including chemotherapy, increases. Namibia introduced single-donor apheresis PLT collections in 2007 to increase PLT

  19. Tritium monitor and collection system

    Science.gov (United States)

    Bourne, G.L.; Meikrantz, D.H.; Ely, W.E.; Tuggle, D.G.; Grafwallner, E.G.; Wickham, K.L.; Maltrud, H.R.; Baker, J.D.

    1992-01-14

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter. 7 figs.

  20. Early intraoperative blood collection does not affect complete blood counts, von Willebrand factor or factor VIII levels in normal children.

    Science.gov (United States)

    Darwish, Hanni; Mundell, Gillianne; Engen, Dale; Lillicrap, David; Silva, Mariana; James, Paula

    2011-01-01

    Obtaining blood from children for research studies can be difficult, particularly for controls. One solution is to obtain samples during elective surgery; however, consideration must be given to the potential effects of the timing of phlebotomy. Ten children were recruited and phlebotomy was carried out during a preoperative clinic visit and intraoperatively immediately after the induction of anesthesia but before the start of surgery. CBCs, VWF, and FVIII levels were measured at both time points and no significant differences were seen. This negative result may be beneficial to pediatric research by suggesting that early intraoperative blood collection for controls does not affect the results.

  1. Determination of reference intervals and comparison of venous blood gas parameters using standard and non-standard collection methods in 24 cats.

    Science.gov (United States)

    Bachmann, Karin; Kutter, Annette Pn; Schefer, Rahel Jud; Marly-Voquer, Charlotte; Sigrist, Nadja

    2017-08-01

    Objectives The aim of this study was to determine in-house reference intervals (RIs) for venous blood analysis with the RAPIDPoint 500 blood gas analyser using blood gas syringes (BGSs) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGSs. Methods Venous blood was collected from 24 healthy cats and directly transferred into a BGS and an LH tube. The BGS was immediately analysed on the RAPIDPoint 500 followed by the LH tube. The BGSs and LH tubes were compared using paired t-test or Wilcoxon matched-pairs signed-rank test, Bland-Altman and Passing-Bablok analysis. To assess clinical relevance, bias or percentage bias between BGSs and LH tubes was compared with the allowable total error (TEa) recommended for the respective parameter. Results Based on the values obtained from the BGSs, RIs were calculated for the evaluated parameters, including blood gases, electrolytes, glucose and lactate. Values derived from LH tubes showed no significant difference for standard bicarbonate, whole blood base excess, haematocrit, total haemoglobin, sodium, potassium, chloride, glucose and lactate, while pH, partial pressure of carbon dioxide and oxygen, actual bicarbonate, extracellular base excess, ionised calcium and anion gap were significantly different to the samples collected in BGSs ( P glucose and lactate can be made based on blood collected in LH tubes and analysed within 5 mins. For pH, partial pressure of carbon dioxide and oxygen, extracellular base excess, anion gap and ionised calcium the clinically relevant alterations have to be considered if analysed in LH tubes.

  2. Isolation of endothelial colony-forming cells from blood samples collected from the jugular and cephalic veins of healthy adult horses.

    Science.gov (United States)

    Sharpe, Ashley N; Seeto, Wen J; Winter, Randolph L; Zhong, Qiao; Lipke, Elizabeth A; Wooldridge, Anne A

    2016-10-01

    OBJECTIVE To evaluate optimal isolation of endothelial colony-forming cells (ECFCs) from peripheral blood of horses. SAMPLE Jugular and cephalic venous blood samples from 17 adult horses. PROCEDURES Each blood sample was divided; isolation was performed with whole blood adherence (WBA) and density gradient centrifugation (DGC). Isolated cells were characterized by uptake of 1,1'-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate-labeled acetylated low-density lipoprotein (DiI-Ac-LDL), vascular tubule formation, and expression of endothelial (CD34, CD105, vascular endothelial growth factor receptor-2, and von Willebrand factor) and hematopoietic (CD14) cell markers by use of indirect immunofluorescence assay (IFA) and flow cytometry. RESULTS Colonies with cobblestone morphology were isolated from 15 of 17 horses. Blood collected from the cephalic vein yielded colonies significantly more often (14/17 horses) than did blood collected from the jugular vein (8/17 horses). Of 14 cephalic blood samples with colonies, 13 were obtained with DGC and 8 with WBA. Of 8 jugular blood samples with colonies, 8 were obtained with DGC and 4 with WBA. Colony frequency (colonies per milliliter of blood) was significantly higher for cephalic blood samples and samples isolated with DGC. Cells formed vascular tubules, had uptake of DiI-Ac-LDL, and expressed endothelial markers by use of IFA and flow cytometry, which confirmed their identity as ECFCs. CONCLUSIONS AND CLINICAL RELEVANCE Maximum yield of ECFCs was obtained for blood samples collected from both the jugular and cephalic veins and use of DGC to isolate cells. Consistent yield of ECFCs from peripheral blood of horses will enable studies to evaluate diagnostic and therapeutic uses.

  3. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  4. Blood component fractionation: manual versus automatic procedures.

    Science.gov (United States)

    Pasqualetti, Daniela; Ghirardini, Alessandro; Cristina Arista, Maria; Vaglio, Stefania; Fakeri, Azis; Waldman, Alan A; Girelli, Gabriella

    2004-02-01

    Over the last few years, quality system requirements have been introduced for blood components. The necessary compliance with standard productions will have a considerable impact on Blood Banks. The introduction of automated methods is the most satisfactory means to meet these requirements for blood component preparation. A new device has been developed to automate the fractionation of blood into components. We evaluated the efficacy of this instrument as compared to manual methods. A total of 218 units of blood have been collected, into several different commercial blood bag systems (77 into standard quadruple bag systems, 141 into bag systems with integrated in line filters), and used to evaluate the universality of the instrument. Whole blood units were processed using the Top/Top system and the Compomat G4 (Fresenius HemoCare). A separate program protocol was developed for each kind of bag. Use of the Compomat G4 resulted in a statistically significant (pblood components, and has been shown adaptable to use with different blood bag systems.

  5. Bridging the gap between sample collection and laboratory analysis: using dried blood spots to identify human exposure to chemical agents

    Science.gov (United States)

    Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.

    2016-05-01

    Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.

  6. Particle Swarm Optimization Algorithm for Optimizing Assignment of Blood in Blood Banking System

    Science.gov (United States)

    Olusanya, Micheal O.; Arasomwan, Martins A.; Adewumi, Aderemi O.

    2015-01-01

    This paper reports the performance of particle swarm optimization (PSO) for the assignment of blood to meet patients' blood transfusion requests for blood transfusion. While the drive for blood donation lingers, there is need for effective and efficient management of available blood in blood banking systems. Moreover, inherent danger of transfusing wrong blood types to patients, unnecessary importation of blood units from external sources, and wastage of blood products due to nonusage necessitate the development of mathematical models and techniques for effective handling of blood distribution among available blood types in order to minimize wastages and importation from external sources. This gives rise to the blood assignment problem (BAP) introduced recently in literature. We propose a queue and multiple knapsack models with PSO-based solution to address this challenge. Simulation is based on sets of randomly generated data that mimic real-world population distribution of blood types. Results obtained show the efficiency of the proposed algorithm for BAP with no blood units wasted and very low importation, where necessary, from outside the blood bank. The result therefore can serve as a benchmark and basis for decision support tools for real-life deployment. PMID:25815046

  7. Particle swarm optimization algorithm for optimizing assignment of blood in blood banking system.

    Science.gov (United States)

    Olusanya, Micheal O; Arasomwan, Martins A; Adewumi, Aderemi O

    2015-01-01

    This paper reports the performance of particle swarm optimization (PSO) for the assignment of blood to meet patients' blood transfusion requests for blood transfusion. While the drive for blood donation lingers, there is need for effective and efficient management of available blood in blood banking systems. Moreover, inherent danger of transfusing wrong blood types to patients, unnecessary importation of blood units from external sources, and wastage of blood products due to nonusage necessitate the development of mathematical models and techniques for effective handling of blood distribution among available blood types in order to minimize wastages and importation from external sources. This gives rise to the blood assignment problem (BAP) introduced recently in literature. We propose a queue and multiple knapsack models with PSO-based solution to address this challenge. Simulation is based on sets of randomly generated data that mimic real-world population distribution of blood types. Results obtained show the efficiency of the proposed algorithm for BAP with no blood units wasted and very low importation, where necessary, from outside the blood bank. The result therefore can serve as a benchmark and basis for decision support tools for real-life deployment.

  8. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  9. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    Science.gov (United States)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood

  10. Comparison of equine platelet function and survival in whole blood collected in acid-citrate-dextrose solution or citrate-phosphate-dextrose-adenine solution.

    Science.gov (United States)

    Bozorgmanesh, Rana; Sutton-Burges, Julie W; Tablin, Fern

    2017-06-01

    Equine whole blood collection and storage methods have been evaluated to assess red blood cell viability; however, platelet (PLT) viability has not been comprehensively assessed. The purpose of the study was to compare viability of PLTs collected in whole blood into 2 different anticoagulants. Whole blood from 6 healthy adult Thoroughbred horses was collected into citrate-phosphate-dextrose-adenine (CPDA) or acid-citrate-dextrose (ACD). Platelet count, pH, and concentrations of glucose, lactate, carbon dioxide, oxygen, bicarbonate, sodium, potassium, and chloride were measured within 10 minutes of collection and then again one hour later at which time PLT aggregometry was performed to assess PLT function. Aggregometry mean amplitudes were significantly higher in CPDA compared to ACD. Blood glucose, pH, bicarbonate, sodium, and lactate concentrations were significantly higher in CPDA compared to ACD. Lactate concentration was higher following one hour in either anticoagulant. Potassium, oxygen, and carbon dioxide concentrations were significantly higher in ACD compared to CPDA at collection. Platelet aggregometry results suggest that CPDA is superior to ACD for maintaining PLT viability following whole blood collection. This may be associated with the higher, more neutral pH as well as an increase in glucose available for metabolism. Although lactate was increased in the CPDA samples it was not high enough to decrease pH and therefore may not have been high enough to cause morphologic lesions and loss of PLT viability. © 2017 American Society for Veterinary Clinical Pathology.

  11. Donor Hemovigilance Programme in managing Blood Transfusion Needs: Complications of Whole Blood Donation

    OpenAIRE

    S Mangwana

    2013-01-01

    Background: Hemovigilance like quality systems and audits have become an integral part of Blood Transfusion Services in the developed countries and has contributed greatly to its development. Hemovigilance begins with donors and must enable the collection of information on reactions occurring during the donation of blood, selections of donors and to prevent such incidents. The aim of study was to help identify the trends of adverse events , occurring in blood donors at a tertiary-care hospita...

  12. Development of blood extraction system for health monitoring system

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2004-03-01

    The purpose of this research is to develop the compact human blood sampling device applied for a health monitoring system(HMS), which is called "Mobile Hospital". The HMS consists of (1) a micro electrical pumping system for blood extraction, (2) a bio-sensor to detect and evaluate an amount of Glucose, Cholesterol and Urea in extracted blood, by using enzyme such as Glucoseoxidase (GOD), Cholesteroloxidase and Urease. The mechanical design elements of the device are bio-compatible microneedle, indentation unit using a shape memory alloy(SMA) actuator and pumping unit using a piezoelectric microactuator. The design concept is the biomimetic micromachine of female mosquito"s blood sampling mechanism. The performances of the main mechanical elements such as indentation force of the microneedle, actual stroke of the indentation unit using a SMA actuator and liquid sampling ability of the pumping unit using PZT piezoelectric microactuator were measured. The 3 mm stroke of the indentation load generated by SMA actuator was 0.8mN. The amount of imitation blood extracted by using bimorph PZT actuators was about 0.5 microliters for 10 sec. A 60-micrometer outer diameter and 25-micrometer inner diameter Titanium microneedle, which size is same as female mosquito"s labium, was produced by sputter deposition.

  13. Portable blood extraction device integrated with biomedical monitoring system

    Science.gov (United States)

    Khumpuang, S.; Horade, M.; Fujioka, K.; Sugiyama, S.

    2006-01-01

    Painless and portable blood extraction device has been immersed in the world of miniaturization on bio-medical research particularly in manufacturing point-of-care systems. The fabrication of a blood extraction device integrated with an electrolyte-monitoring system is reported in this paper. The device has advantages in precise controlled dosage of blood extracted including the slightly damaged blood vessels and nervous system. The in-house blood diagnostic will become simple for the patients. Main components of the portable system are; the blood extraction device and electrolyte-monitoring system. The monitoring system consists of ISFET (Ion Selective Field Effect Transistor) for measuring the concentration level of minerals in blood. In this work, we measured the level of 3 ions; Na+, K+ and Cl-. The mentioned ions are frequently required the measurement since their concentration levels in the blood can indicate whether the kidney, pancreas, liver or heart is being malfunction. The fabrication of the whole system and experimentation on each ISM (Ion Sensitive Membrane) will be provided. Taking the advantages of LIGA technology, the 100 hollow microneedles fabricated by Synchrotron Radiation deep X-ray lithography through PCT (Plane-pattern to Cross-section Transfer) technique have been consisted in 5x5 mm2 area. The microneedle is 300 μm in base-diameter, 500 μm-pitch, 800 μm-height and 50 μm hole-diameter. The total size of the blood extraction device is 2x2x2 cm 3. The package is made from a plastic socket including slots for inserting microneedle array and ISFET connecting to an electrical circuit for the monitoring. Through the dimensional design for simply handling and selection of disposable material, the patients can self-evaluate the critical level of the body minerals in anywhere and anytime.

  14. The Chikungunya epidemic in Italy and its repercussion on the blood system.

    Science.gov (United States)

    Liumbruno, Giancarlo Maria; Calteri, Deanna; Petropulacos, Kyriakoula; Mattivi, Andrea; Po, Claudio; Macini, Pierluigi; Tomasini, Ivana; Zucchelli, Paolo; Silvestri, Anna Rita; Sambri, Vittorio; Pupella, Simonetta; Catalano, Liviana; Piccinini, Vanessa; Calizzani, Gabriele; Grazzini, Giuliano

    2008-10-01

    The Chikungunya virus (CHIKV) is transmitted by Aedes mosquitoes and recently caused a massive epidemic on La Réunion Island, in the Indian Ocean. Between July and September 2007 it caused the first autochthonous epidemic outbreak in Europe, in the Region of Emilia-Romagna in the north-east of Italy. After the first reports of an unusually high number of patients with a febrile illness of unknown origin in two contiguous villages, an outbreak investigation was carried out to identify the primary source of infection, the modes of transmission and the dynamics of the epidemic. An active surveillance system was also implemented. Laboratory diagnosis was performed through serology and polymerase chain reaction (PCR) analysis. Blood donation was discontinued in the areas involved from September to October 2007 and specific precautionary blood safety and self-sufficiency measures were adopted by the regional health and blood authorities and the National Blood Centre. An estimate method to early assess the risk of viraemic blood donations by asymptomatic donors was developed, as a tool for "pragmatic" risk assessment and management, aiming at providing a reliable order of magnitude of the mean risk of CHIKV transmission through blood transfusion. Two hundred and seventeen cases of CHIKV infection were identified between 4th July and 28th September. The disease was fairly mild in most of the cases. The precautionary measures adopted in the blood system caused a considerable reduction of the collection of blood components and of the delivery of plasma to the pharmaceutical industry for contract manufacturing. The estimated risk of CHIKV transmission through blood transfusion peaked in the third week of August. ACHIKV epidemic poses considerable problems for public health authorities, who not only need good routine programmes of vector control and epidemiological surveillance but also local and national emergency plans to sustain the blood supply, so as to promptly deal

  15. Collection and storage of red blood cells with anticoagulant and additive solution with a physiologic pH

    NARCIS (Netherlands)

    Burger, Patrick; Korsten, Herbert; Verhoeven, Arthur J.; de Korte, Dirk; van Bruggen, Robin

    2012-01-01

    BACKGROUND: A donation of whole blood is most commonly collected in acidic citrate-phosphate-dextrose (CPD) variants with pH 5.2 to 6.2 as anticoagulants. Previously, we have shown that the initial pH after red blood cell (RBC) preparation can have an effect on RBCs during storage. First, we

  16. Do autologous blood transfusion systems reduce allogeneic blood transfusion in total knee arthroplasty?

    Science.gov (United States)

    Pawaskar, Aditya; Salunke, Abhijeet Ashok; Kekatpure, Aashay; Chen, Yongsheng; Nambi, G I; Tan, Junhao; Sonawane, Dhiraj; Pathak, Subodhkumar

    2017-09-01

    To study whether autologus blood transfusion systems reduce the requirement of allogneic blood transfusion in patients undergoing total knee arthroplasty. A comprehensive search of the published literature with PubMed, Scopus and Science direct database was performed. The following search terms were used: (total knee replacement) OR (total knee arthroplasty) OR (TKA) AND (blood transfusion) OR (autologous transfusion) OR (autologous transfusion system). Using search syntax, a total of 748 search results were obtained (79 from PubMed, 586 from Science direct and 83 from Scopus). Twenty-one randomized control trials were included for this meta-analysis. The allogenic transfusion rate in autologus blood transfusion (study) group was significantly lower than the control group (28.4 and 53.5 %, respectively) (p value 0.0001, Relative risk: 0.5). The median units of allogenic blood transfused in study control group and control group were 0.1 (0.1-3.0) and 1.3 (0.3-2.6), respectively. The median hospital stay in study group was 9 (6.7-15.6) days and control group was 8.7 (6.6-16.7) days. The median cost incurred for blood transfusion per patient in study and control groups was 175 (85.7-260) and 254.7 (235-300) euros, respectively. This meta-analysis demonstrates that the use of auto-transfusion systems is a cost-effective method to reduce the need for and quantity of allogenic transfusion in elective total knee arthroplasty. Level I.

  17. Systemic arterial hypertension, blood pressure levels and associated factors in schoolchildren

    Directory of Open Access Journals (Sweden)

    Priscila Heleno

    Full Text Available Summary Introduction: Hypertension is a major public health problem in contemporary times and it has high prevalence throughout the world. Objective: To investigate the situation of Systemic Arterial Hypertension in schoolchildren aged 6 to 10 years in Divinópolis/MG-Brazil and associated factors. Method: This is a cross-sectional, epidemiological, descriptive and analytical study, whose population was children aged 6 to 10 years enrolled in public schools in Divinópolis-MG-Brazil. Data collection was conducted from October 2014 to May 2015. Multivariate linear regressions were used to test associations between blood pressure, socioeconomic, anthropometric, dietary and physical activity. Results: The prevalence of hypertension was 15.2% in a sample of 284 children and mean values of systolic blood pressure of 101.7 (±13.2 mmHg and diastolic blood pressure of 66.0 (±11.2 mmHg. The body fat percentage showed significant differences between the genders, with 24.2 and 26.2%, respectively for boys and girls. Significant associations were made between blood pressure levels, body weight, body mass index, waist circumference, body fat percentage, consumption of yogurt, beef /chicken, beans, pizza, sandwich and some behaviors variables. Conclusion: The presented data show important aspects of school profile in the age range 6-10 years, especially related to the behavior of blood pressure.

  18. Factors affecting autologous peripheral blood hematopoietic stem cell collections by large-volume leukapheresis: a single center experience

    Directory of Open Access Journals (Sweden)

    Araci Massami Sakashita

    2011-06-01

    Full Text Available Objective: To evaluate factors affecting peripheral bloodhematopoietic stem cell yield in patients undergoing large-volumeleukapheresis for autologous peripheral blood stem cell collection.Methods: Data from 304 consecutive autologous peripheral bloodstem cell donors mobilized with hematopoietic growth factor (usually G-CSF, associated or not with chemotherapy, at Hospital Israelita Albert Einstein between February 1999 and June 2010 were retrospectively analyzed. The objective was to obtain at least 2 x 106CD34+ cells/kg of body weight. Pre-mobilization factors analyzedincluded patient’s age, gender and diagnosis. Post mobilizationparameters evaluated were pre-apheresis peripheral white bloodcell count, immature circulating cell count, mononuclear cell count,peripheral blood CD34+ cell count, platelet count, and hemoglobinlevel. The effect of pre and post-mobilization factors on hematopoietic stem cell collection yield was investigated using logistic regression analysis (univariate and multivariate approaches. Results: Premobilization factors correlating to poor CD34+ cell yield in univariate analysis were acute myeloid leukemia (p = 0.017 and other hematological diseases (p = 0.023. Significant post-mobilization factors included peripheral blood immature circulating cells (p = 0.001, granulocytes (p = 0.002, hemoglobin level (p = 0.016, and CD34+ cell concentration (p < 0.001 in the first harvesting day. However, according to multivariate analysis, peripheral blood CD34+ cell content (p < 0.001 was the only independent factor that significantly correlated to poor hematopoietic stem cell yield. Conclusion: In this study, peripheral blood CD34+ cell concentration was the only factor significantly correlated to yield in patients submitted to for autologous collection.

  19. A Retrospective Review of the Clinical Characteristics and Blood Glucose Data from Cellnovo System Users using Data Collected from the Cellnovo Online Platform.

    Science.gov (United States)

    Hautier-Suply, Olivia; Friedmann, Yasmin; Shapley, Julian

    2018-04-01

    Technological advances have led to innovative insulin delivery systems for patients with type 1 diabetes mellitus. In particular, the combination of miniature engineering and software algorithms contained in continuous subcutaneous insulin infusion (CSII) system pumps provide the user and the healthcare practitioner with an opportunity to review and adjust blood glucose (BG) levels according to system feedback, and to modify or programme their regimen according to their needs. While CSII pumps record a number of data parameters such as BG level, carbohydrate intake, activity and insulin delivered, these data are generally 'locked in' and can only be accessed by uploading to a cloud-based system, thus information is not contemporaneous. The Cellnovo Diabetes Management System (Cellnovo, Bridgend, UK) allows data to be transmitted securely and wirelessly in real time to a secure server, which is then retrieved by an online platform, the Cellnovo Online platform, enabling continuous access by the user and by clinicians. In this article, the authors describe a retrospective review of the patient data automatically uploaded to the Cellnovo Online platform. Baseline clinical and demographic characteristics collected at the start of pump therapy are shown for all patients, and BG data from a sub-cohort of patients who have been using the system for at least 6 months and who take and record an average of three BG level tests per day are presented to demonstrate glycaemic data over time.

  20. A Blood Bank Information Management System

    Science.gov (United States)

    Farmer, James J.

    1982-01-01

    A computerized Blood Bank Management system is described. Features include product oriented data input, inventory control reports, product utilization reports, rapid retrieval of individual patient reports. Relative benefits of the system are discussed.

  1. Periodontal disease level-butyric acid amounts locally administered in the rat gingival mucosa induce ER stress in the systemic blood.

    Science.gov (United States)

    Cueno, Marni E; Saito, Yuko; Ochiai, Kuniyasu

    2016-05-01

    Periodontal diseases have long been postulated to contribute to systemic diseases and, likewise, it has been proposed that periodontal disease treatment may ameliorate certain systemic diseases. Short-chain fatty acids (SCFA) are major secondary metabolites produced by oral anaerobic bacteria and, among the SCFAs, butyric acid (BA) in high amounts contribute to periodontal disease development. Periodontal disease level-butyric acid (PDL-BA) is found among patients suffering from periodontal disease and has previously shown to induce oxidative stress, whereas, oxidative stress is correlated to endoplasmic reticulum (ER) stress. This would imply that PDL-BA may likewise stimulate ER stress, however, this was never elucidated. A better understanding of the correlation between PDL-BA and systemic ER stress stimulation could shed light on the possible systemic effects of PDL-BA-related periodontal diseases. Here, PDL-BA was injected into the gingival mucosa and the systemic blood obtained from the rat jugular was collected at 0, 15, 60, and 180 min post-injection. Collected blood samples were purified and only the blood cytosol was used throughout this study. Subsequently, we measured blood cytosolic GADD153, Ca(2+), representative apoptotic and inflammatory caspases, and NF-κB amounts. We found that PDL-BA presence increased blood cytosolic GADD153 and Ca(2+) amounts. Moreover, we observed that blood cytosolic caspases and NF-κB were activated only at 60 and 180 min post-injection in the rat gingival mucosa. This suggests that PDL-BA administered through the gingival mucosa may influence the systemic blood via ER stress stimulation and, moreover, prolonged PDL-BA retention in the gingival mucosa may play a significant role in ER stress-related caspase and NF-κB activation. In a periodontal disease scenario, we propose that PDL-BA-related ER stress stimulation leading to the simultaneous activation of apoptosis and inflammation may contribute to periodontal disease

  2. Order of draw practices in venous blood sampling at clinical biochemistry departments in the Danish health care system

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp; Brandt, Ida; Christensen, Anne Vindahl

    2018-01-01

    the procedures in venous blood sampling among clinical biochemistry departments to assess the uniformity of order of blood draw and adherence to international guidelines in the Danish health care system. METHODS: We collected venous order of draw procedures from 49 clinical biochemistry departments at 22 public...... 15189:2012 accreditation (p = .57). CONCLUSIONS: Venous order of draw procedures is diverse at Danish clinical biochemistry departments and show moderate adherence to international guidelines....

  3. A rational framework for production decision making in blood establishments.

    Science.gov (United States)

    Ramoa, Augusto; Maia, Salomé; Lourenço, Anália

    2012-07-24

    SAD_BaSe is a blood bank data analysis software, created to assist in the management of blood donations and the blood production chain in blood establishments. In particular, the system keeps track of several collection and production indicators, enables the definition of collection and production strategies, and the measurement of quality indicators required by the Quality Management System regulating the general operation of blood establishments. This paper describes the general scenario of blood establishments and its main requirements in terms of data management and analysis. It presents the architecture of SAD_BaSe and identifies its main contributions. Specifically, it brings forward the generation of customized reports driven by decision making needs and the use of data mining techniques in the analysis of donor suspensions and donation discards.

  4. A Mathematical Model of Renal Blood Distribution Coupling TGF, MR and Tubular System

    Institute of Scientific and Technical Information of China (English)

    GAO Ci-xiu; YANG Lin; WANG Ke-qiang; XU Shi-xiong; DAI Pei-dong

    2009-01-01

    Objective:To investigate the relationship between renal blood distribution and the physiological activities of the kidney. Methods:A mathematical model is developed based on Hagan-Poiseuille law and mass transport, coupling mechanics of myogenic response (MR), tubuloglomerular feedback (TGF) and the tubular system in the renal medulla. The model parameters, including the permeability coefficients, the vascular lumen radius and the solute concentration at the inlet of the tubes, are derived from the experimental results. Simulations of the blood and water flow in the loop of Henel, the collecting duct and vas rectum, are carried out by the model of the tubular system in the renal medulla, based on conservations of water and solutes for transmural transport. Then the tubular model is coupled with MR and TGF mechanics. Results:The results predict the dynamics of renal autoregulation on its blood pressure and flow,and the distributions are 88.5% in the cortex, 10.3% in the medulla, and 1.2% at papilla,respectively. The fluid flow and solute concentrations along the tubules and vasa recta are obtained. Conclusion:The present model could assess renal functions qualitatively and quantitatively and provide a methodological approach for clinical research.

  5. Colour coding for blood collection tube closures - a call for harmonisation

    DEFF Research Database (Denmark)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell

    2015-01-01

    including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have...... not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce...

  6. Blood as integral system of an organism

    Directory of Open Access Journals (Sweden)

    Майя Розметовна Верголяс

    2016-02-01

    Full Text Available Relevance of use of hematological blood parameters for monitoring as markers of various physiological and pathological processes is substantiated. It is shown that the blood is an important system of the body, has all the reactive characteristics of tissues, its sensitivity to pathological stimuli is very high. The reaction of the organism to the irritation of toxic or infectious nature manifests itself in the change of quantitative composition of peripheral blood cells

  7. Identification of host blood from engorged mosquitoes collected in western Uganda using cytochrome oxidase I gene sequences.

    Science.gov (United States)

    Crabtree, Mary B; Kading, Rebekah C; Mutebi, John-Paul; Lutwama, Julius J; Miller, Barry R

    2013-07-01

    Emerging infectious disease events are frequently caused by arthropod-borne viruses (arboviruses) that are maintained in a zoonotic cycle between arthropod vectors and vertebrate wildlife species, with spillover to humans in areas where human and wildlife populations interface. The greater Congo basin region, including Uganda, has historically been a hot spot for emergence of known and novel arboviruses. Surveillance of arthropod vectors is a critical activity in monitoring and predicting outbreaks of arboviral disease, and identification of blood meals in engorged arthropods collected during surveillance efforts provides insight into the ecology of arboviruses and their vectors. As part of an ongoing arbovirus surveillance project we analyzed blood meals from engorged mosquitoes collected at five sites in western Uganda November 2008-June 2010. We extracted DNA from the dissected and triturated abdomens of engorged mosquito specimens. Mitochondrial cytochrome c oxidase I gene sequence was amplified by PCR and sequenced to identify the source of the mosquito host blood. Blood meals were analyzed from 533 engorged mosquito specimens; 440 of these blood meals were successfully identified from 33 mosquito species. Species identifications were made for 285 of the 440 identified specimens with the remainder identified to genus, family, or order. When combined with published arbovirus isolation and serologic survey data, our results suggest possible vector-reservoir relationships for several arboviruses, including Rift Valley fever virus and West Nile virus.

  8. [Measures to prevent patient identification errors in blood collection/physiological function testing utilizing a laboratory information system].

    Science.gov (United States)

    Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji

    2013-08-01

    We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.

  9. Blood Sample Transportation by Pneumatic Transportation Systems

    DEFF Research Database (Denmark)

    Nybo, Mads; Lund, Merete E; Titlestad, Kjell

    2018-01-01

    BACKGROUND: Pneumatic transportation systems (PTSs) are increasingly used for transportation of blood samples to the core laboratory. Many studies have investigated the impact of these systems on different types of analyses, but to elucidate whether PTSs in general are safe for transportation...... analysis, and the hemolysis index). CONCLUSIONS: Owing to their high degree of heterogeneity, the retrieved studies were unable to supply evidence for the safety of using PTSs for blood sample transportation. In consequence, laboratories need to measure and document the actual acceleration forces...

  10. Impact of donor- and collection-related variables on product quality in ex utero cord blood banking.

    Science.gov (United States)

    Askari, Sabeen; Miller, John; Chrysler, Gayl; McCullough, Jeffrey

    2005-02-01

    Optimizing product quality is a current focus in cord blood banking. This study evaluates the role of selected donor- and collection-related variables. Retrospective review was performed of cord blood units (CBUs) collected ex utero between February 1, 2000, and February 28, 2002. Preprocessing volume and total nucleated cell (TNC) counts and postprocessing CD34 cell counts were used as product quality indicators. Of 2084 CBUs, volume determinations and TNC counts were performed on 1628 and CD34+ counts on 1124 CBUs. Mean volume and TNC and CD34+ counts were 85.2 mL, 118.9 x 10(7), and 5.2 x 10(6), respectively. In univariate analysis, placental weight of greater than 500 g and meconium in amniotic fluid correlated with better volume and TNC and CD34+ counts. Greater than 40 weeks' gestation predicted enhanced volume and TNC count. Cesarean section, two- versus one-person collection, and not greater than 5 minutes between placental delivery and collection produced superior volume. Increased TNC count was also seen in Caucasian women, primigravidae, female newborns, and collection duration of more than 5 minutes. A time between delivery of newborn and placenta of not greater than 10 minutes predicted better volume and CD34+ count. By regression analysis, collection within not greater than 5 minutes of placental delivery produced superior volume and TNC count. Donor selection and collection technique modifications may improve product quality. TNC count appears to be more affected by different variables than CD34+ count.

  11. 21 CFR 864.9175 - Automated blood grouping and antibody test system.

    Science.gov (United States)

    2010-04-01

    ...) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red blood cells) and to detect antibodies to blood group antigens. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system...

  12. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  13. System for Collecting Biosignal Data from Multiple Patient Monitoring Systems.

    Science.gov (United States)

    Yoon, Dukyong; Lee, Sukhoon; Kim, Tae Young; Ko, JeongGil; Chung, Wou Young; Park, Rae Woong

    2017-10-01

    Biosignal data include important physiological information. For that reason, many devices and systems have been developed, but there has not been enough consideration of how to collect and integrate raw data from multiple systems. To overcome this limitation, we have developed a system for collecting and integrating biosignal data from two patient monitoring systems. We developed an interface to extract biosignal data from Nihon Kohden and Philips monitoring systems. The Nihon Kohden system has a central server for the temporary storage of raw waveform data, which can be requested using the HL7 protocol. However, the Philips system used in our hospital cannot save raw waveform data. Therefore, our system was connected to monitoring devices using the RS232 protocol. After collection, the data were transformed and stored in a unified format. From September 2016 to August 2017, we collected approximately 117 patient-years of waveform data from 1,268 patients in 79 beds of five intensive care units. Because the two systems use the same data storage format, the application software could be run without compatibility issues. Our system collects biosignal data from different systems in a unified format. The data collected by the system can be used to develop algorithms or applications without the need to consider the source of the data.

  14. 75 FR 20602 - Agency Information Collection Activities: Proposed Collection: Comment Request

    Science.gov (United States)

    2010-04-20

    ... Stem Cell Therapeutic Outcomes Database (OMB No. 0915-0310)--Extension The Stem Cell Therapeutic and Research Act of 2005 provides for the collection and maintenance of human cord blood stem cells for the... Systems Bureau (HSB) has established the Stem Cell Therapeutic Outcomes Database. Operation of this...

  15. Effect of order of draw of blood samples during phlebotomy on routine biochemistry results.

    Science.gov (United States)

    Sulaiman, Raashda A; Cornes, Michael P; Whitehead, Simon J; Othonos, Nadia; Ford, Clare; Gama, Rousseau

    2011-11-01

    To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.

  16. PREDICTIVE VALUE OF CD34+ CELLS IN BLOOD OF PATIENT/DONOR BEFORE HEMATOPOIETIC STEM CELLS COLLECTION BY LEUKAPHERESIS

    Directory of Open Access Journals (Sweden)

    Dragoslav Domanovič

    2004-12-01

    Full Text Available Background. In the study we tried to define a predictive value of the circulating CD34+ cells in patients/ donors blood for estimation of the hematopoietic stem cells (HSC collection efficacy determine the optimal time to initiate the collection by leukapheresis procedure.Methods. We retrospectively analyzed 75 collections of HSC using the Amicus cell separator in 39 patients and 15 donors. Circulating CD34+cell counts in patients/donors were compared to the achieved CD34+ cell yields to determine its predictive value for the collection of a targeted yield of > 2 × 106 CD34+ cells/kg body weight of patient.Results. The results of cell counts confirmed that mobilization regimens were successful and HSC collections efficient. High correlation coefficient (r = 0.82 between the number of circulating CD34+ cells before collection and CD34+ cell yield/kg of patient’s body weight was statistically significant (p < 0.05. With ROC analysis we determined the cut-off value 42 × 106/l CD34+ cell counts in the blood of patients/donors before collection that had a positive predictive value 87% and a negative predictive value 91.6%.Conclusions. Analysis showed that the number of circulating CD34+ cells before the procedure express a very high predictive value and can be used for determining the optimal time to initiate collection of HSC by leukapheresis.

  17. Point-of-care, portable microfluidic blood analyzer system

    Science.gov (United States)

    Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.

    2012-03-01

    Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.

  18. Accurate costs of blood transfusion: a microcosting of administering blood products in the United Kingdom National Health Service.

    Science.gov (United States)

    Stokes, Elizabeth A; Wordsworth, Sarah; Staves, Julie; Mundy, Nicola; Skelly, Jane; Radford, Kelly; Stanworth, Simon J

    2018-04-01

    In an environment of limited health care resources, it is crucial for health care systems which provide blood transfusion to have accurate and comprehensive information on the costs of transfusion, incorporating not only the costs of blood products, but also their administration. Unfortunately, in many countries accurate costs for administering blood are not available. Our study aimed to generate comprehensive estimates of the costs of administering transfusions for the UK National Health Service. A detailed microcosting study was used to cost two key inputs into transfusion: transfusion laboratory and nursing inputs. For each input, data collection forms were developed to capture staff time, equipment, and consumables associated with each step in the transfusion process. Costing results were combined with costs of blood product wastage to calculate the cost per unit transfused, separately for different blood products. Data were collected in 2014/15 British pounds and converted to US dollars. A total of 438 data collection forms were completed by 74 staff. The cost of administering blood was $71 (£49) per unit for red blood cells, $84 (£58) for platelets, $55 (£38) for fresh-frozen plasma, and $72 (£49) for cryoprecipitate. Blood administration costs add substantially to the costs of the blood products themselves. These are frequently incurred costs; applying estimates to the blood components supplied to UK hospitals in 2015, the annual cost of blood administration, excluding blood products, exceeds $175 (£120) million. These results provide more accurate estimates of the total costs of transfusion than those previously available. © 2018 AABB.

  19. Adjustment of Cell-Type Composition Minimizes Systematic Bias in Blood DNA Methylation Profiles Derived by DNA Collection Protocols.

    Science.gov (United States)

    Shiwa, Yuh; Hachiya, Tsuyoshi; Furukawa, Ryohei; Ohmomo, Hideki; Ono, Kanako; Kudo, Hisaaki; Hata, Jun; Hozawa, Atsushi; Iwasaki, Motoki; Matsuda, Koichi; Minegishi, Naoko; Satoh, Mamoru; Tanno, Kozo; Yamaji, Taiki; Wakai, Kenji; Hitomi, Jiro; Kiyohara, Yutaka; Kubo, Michiaki; Tanaka, Hideo; Tsugane, Shoichiro; Yamamoto, Masayuki; Sobue, Kenji; Shimizu, Atsushi

    2016-01-01

    Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS) using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03) when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50) when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14) by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45) and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17). These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.

  20. Adjustment of Cell-Type Composition Minimizes Systematic Bias in Blood DNA Methylation Profiles Derived by DNA Collection Protocols.

    Directory of Open Access Journals (Sweden)

    Yuh Shiwa

    Full Text Available Differences in DNA collection protocols may be a potential confounder in epigenome-wide association studies (EWAS using a large number of blood specimens from multiple biobanks and/or cohorts. Here we show that pre-analytical procedures involved in DNA collection can induce systematic bias in the DNA methylation profiles of blood cells that can be adjusted by cell-type composition variables. In Experiment 1, whole blood from 16 volunteers was collected to examine the effect of a 24 h storage period at 4°C on DNA methylation profiles as measured using the Infinium HumanMethylation450 BeadChip array. Our statistical analysis showed that the P-value distribution of more than 450,000 CpG sites was similar to the theoretical distribution (in quantile-quantile plot, λ = 1.03 when comparing two control replicates, which was remarkably deviated from the theoretical distribution (λ = 1.50 when comparing control and storage conditions. We then considered cell-type composition as a possible cause of the observed bias in DNA methylation profiles and found that the bias associated with the cold storage condition was largely decreased (λ adjusted = 1.14 by taking into account a cell-type composition variable. As such, we compared four respective sample collection protocols used in large-scale Japanese biobanks or cohorts as well as two control replicates. Systematic biases in DNA methylation profiles were observed between control and three of four protocols without adjustment of cell-type composition (λ = 1.12-1.45 and no remarkable biases were seen after adjusting for cell-type composition in all four protocols (λ adjusted = 1.00-1.17. These results revealed important implications for comparing DNA methylation profiles between blood specimens from different sources and may lead to discovery of disease-associated DNA methylation markers and the development of DNA methylation profile-based predictive risk models.

  1. A new temperature collection system

    International Nuclear Information System (INIS)

    Kong Wenchuang; Wang Daihua; Zhang Zhijie

    2011-01-01

    According to the characteristics of explosion field temperature testing, a new temperature collection system based on complex programmable logic device (CPLD), single chip microcontroller (SCM) and static ram (SRAM) is proposed. The system adopts the NANMAC E12 type of thermocouple as the temperature sensor, DS600 temperature sensor for cold temperature compensation, with rapid synchronous collection, trigger and working parameters adjustable characteristics. The system used SCM combined with USB communication interface, easy operation and reliable. (authors)

  2. Development of blood extraction system designed by female mosquito's blood sampling mechanism for bio-MEMS

    Science.gov (United States)

    Tsuchiya, Kazuyoshi; Nakanishi, Naoyuki; Nakamachi, Eiji

    2005-02-01

    A compact and wearable wristwatch type Bio-MEMS such as a health monitoring system (HMS) to detect blood sugar level for diabetic patient, was newly developed. The HMS consists of (1) a indentation unit with a microneedle to generate the skin penetration force using a shape memory alloy(SMA) actuator, (2) a pumping unit using a bimorph PZT piezoelectric actuator to extract the blood and (3) a gold (Au) electrode as a biosensor immobilized GOx and attached to the gate electrode of MOSFET to detect the amount of Glucose in extracted blood. GOx was immobilized on a self assembled spacer combined with an Au electrode by the cross-link method using BSA as an additional bonding material. The device can extract blood in a few microliter through a painless microneedle with the negative pressure by deflection of the bimorph PZT piezoelectric actuator produced in the blood chamber, by the similar way the female mosquito extracts human blood with muscle motion to flex or relax. The performances of the liquid sampling ability of the pumping unit through a microneedle (3.8mm length, 100μm internal diameter) using the bimorph PZT piezoelectric microactuator were measured. The blood extraction micro device could extract human blood at the speed of 2μl/min, and it is enough volume to measure a glucose level, compared to the amount of commercial based glucose level monitor. The electrode embedded in the blood extraction device chamber could detect electrons generated by the hydrolysis of hydrogen peroxide produced by the reaction between GOx and glucose in a few microliter extracted blood, using the constant electric current measurement system of the MOSFET type hybrid biosensor. The output voltage for the glucose diluted in the chamber was increased lineally with increase of the glucose concentration.

  3. Collective systems:physical and information exergies.

    Energy Technology Data Exchange (ETDEWEB)

    Robinett, Rush D. III (.; ); Wilson, David Gerald

    2007-04-01

    Collective systems are typically defined as a group of agents (physical and/or cyber) that work together to produce a collective behavior with a value greater than the sum of the individual parts. This amplification or synergy can be harnessed by solving an inverse problem via an information-flow/communications grid: given a desired macroscopic/collective behavior find the required microscopic/individual behavior of each agent and the required communications grid. The goal of this report is to describe the fundamental nature of the Hamiltonian function in the design of collective systems (solve the inverse problem) and the connections between and values of physical and information exergies intrinsic to collective systems. In particular, physical and information exergies are shown to be equivalent based on thermodynamics and Hamiltonian mechanics.

  4. Performance of Gram staining on blood cultures flagged negative by an automated blood culture system.

    Science.gov (United States)

    Peretz, A; Isakovich, N; Pastukh, N; Koifman, A; Glyatman, T; Brodsky, D

    2015-08-01

    Blood is one of the most important specimens sent to a microbiology laboratory for culture. Most blood cultures are incubated for 5-7 days, except in cases where there is a suspicion of infection caused by microorganisms that proliferate slowly, or infections expressed by a small number of bacteria in the bloodstream. Therefore, at the end of incubation, misidentification of positive cultures and false-negative results are a real possibility. The aim of this work was to perform a confirmation by Gram staining of the lack of any microorganisms in blood cultures that were identified as negative by the BACTEC™ FX system at the end of incubation. All bottles defined as negative by the BACTEC FX system were Gram-stained using an automatic device and inoculated on solid growth media. In our work, 15 cultures that were defined as negative by the BACTEC FX system at the end of the incubation were found to contain microorganisms when Gram-stained. The main characteristic of most bacteria and fungi growing in the culture bottles that were defined as negative was slow growth. This finding raises a problematic issue concerning the need to perform Gram staining of all blood cultures, which could overload the routine laboratory work, especially laboratories serving large medical centers and receiving a large number of blood cultures.

  5. Relationship between systemic hemodynamics and ambulatory blood pressure level are sex dependent.

    Science.gov (United States)

    Alfie, J; Waisman, G D; Galarza, C R; Magi, M I; Vasvari, F; Mayorga, L M; Cámera, M I

    1995-12-01

    Sex-related differences in systemic hemodynamics were analyzed by means of cardiac index and systemic vascular resistance according to the level of daytime ambulatory blood pressure. In addition, we assessed the relations between ambulatory blood pressure measurements and systemic hemodynamics in male and female patients. We prospectively included 52 women and 53 men referred to our unit for evaluation of arterial hypertension. Women and men were grouped according to the level of daytime mean arterial pressure: or = 110 mm Hg. Patients underwent noninvasive evaluation of resting hemodynamics (impedance cardiography) and 24-hour ambulatory blood pressure monitoring. Compared with women men with lower daytime blood pressure had a 12% higher systemic vascular resistance index (P = NS) and a 14% lower cardiac index (P < .02), whereas men with higher daytime blood pressure had a 25% higher vascular resistance (P < .003) and a 21% lower cardiac index (P < .0004). Furthermore, in men systemic vascular resistance correlated positively with both daytime and nighttime systolic and diastolic blood pressures, whereas cardiac index correlated negatively only with daytime diastolic blood pressure. In contrast, women did not exhibit any significant correlation between hemodynamic parameters and ambulatory blood pressure measurements. In conclusion, sex-related differences in systemic hemodynamics were more pronounced in the group with higher daytime hypertension. The relations between systemic hemodynamics and ambulatory blood pressure level depended on the sex of the patient. In men a progressive circulatory impairment underlies the increasing level of ambulatory blood pressure, but this was not observed in women.

  6. Successful collection of peripheral blood stem cells upon VIDE chemomobilization in sarcoma patients.

    Science.gov (United States)

    Kriegsmann, Katharina; Heilig, Christoph; Cremer, Martin; Novotny, Philipp; Kriegsmann, Mark; Bruckner, Thomas; Müller-Tidow, Carsten; Egerer, Gerlinde; Wuchter, Patrick

    2017-11-01

    In patients with Ewing sarcoma and some distinct subgroups of soft tissue sarcoma (STS), a quantitatively sufficient autologous peripheral blood stem cell (PBSC) collection for stem cell support might facilitate treatment continuation, dose-intensification, and high-dose chemotherapy. Here, we provide a detailed evaluation of PBSC collection upon vincristine, ifosfamide, doxorubicin, and etoposide (VIDE) chemomobilization. Mobilization and collection parameters of 42 sarcoma patients (Ewing sarcoma n = 35, other STS n = 7) were analyzed retrospectively. Data were evaluated with regard to the number of previous VIDE therapy cycles. All patients reached the collection goal of ≥2.0 × 10 6 CD34 + cells/kg body weight (bw) upon VIDE/G-CSF mobilization, in the majority of cases with one single leukapheresis (LP) session (n = 29, 69%). No significant differences were identified with regard to mobilization and collection variables or the number of previous induction VIDE therapy cycles. However, upon 5 cycles of VIDE, we found the highest relative proportion of patients who required two or three LP sessions. Our data demonstrate the feasibility of successful PBSC collection upon VIDE chemomobilization even after up to five cycles of induction therapy, while at the same time the increasing risk of bone marrow exhaustion with every consecutive cycle is outlined. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Acceptability of study procedures (self-collected introital swabs, blood draws and stool sample collection) by students 10-16 years for an HPV vaccine effectiveness study: a pilot study.

    Science.gov (United States)

    Nakalembe, Miriam; Mutyaba, Twaha; Mirembe, Florence

    2016-03-16

    A cohort study was planned to evaluate vaccine immunogenicity and effect of malaria and helminth co-infections on the bivalent Human papilloma virus (HPV) vaccine. The study would involve self collected introital swabs, blood draws and stool sample collection. We therefore conducted a pilot study to assess the acceptability of these procedures among the students and their parents. A cross-sectional study among forty four students from two purposively selected primary schools of Western Uganda. Exit interviews and two focus group discussions (FGD) (for parents) were conducted. Acceptability was measured by willingness to undergo the procedures again, recommending the procedures to others as well as proportion of introital swabs positive for β globulin. FGD determined acceptability of the parents and explored opinions and perceptions that would influence their decisions. HPV-16/18 and β globulin deoxyribonucleic acid (DNA) were analysed using a polymerase chain reaction (PCR) kit. All the students (100%) in the study were willing to provide a self- collected introital swab and a stool sample as well as recommending their friends while (86.3%) were willing for blood draws. There were 40/44 (90.1%) self collected introital swabs that had positive result for human β globulin though none of them was positive for HPV-16/18. In the FGD, it emerged that parents concerns were on the blood draws and introital swab collection which were addressed. The study procedures were highly acceptable among this study population of students and their parents. Follow-up to assess HPV vaccine effectiveness and factors that may influence the vaccine in this age group is feasible.

  8. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  9. Increased preoperative collection of autologous blood with recombinant human erythropoietin therapy in tertiary care hospitals of Jammu

    Directory of Open Access Journals (Sweden)

    Kumkum Sharma

    2013-01-01

    Full Text Available Introduction: To study whether the administration of recombinant human erythropoietin increases the amount of autologous blood that can be collected before orthopaedic surgery. Materials and Methods: We conducted a randomized controlled trial of recombinant human erythropoietin in 68 adults scheduled for elective orthopedic procedures. The patients received either erythropoietin 600 units/kg of body weight or placebo intravenously every 5 th day prior to each phlebotomy for 21 days during which time up to 5 units of blood was collected. Patients were excluded from donation when their hematocrit values were less than 33%. All patients received iron sulphate 325mg orally 3 times daily. The mean number of units collected per patient was 4.33 ± 0.4 for erythropoietin group and 3.05± 0.71 for the placebo group. Results: The mean packed red cell volume donated by patients who received erythropoietin was 32% greater than that donated by patients who received placebo (196.3 vs. 169.4 ml, p<0.05. 68% in the placebo group and 9% of patients treated with erythropoietin were unable to donate ≥4 units. No adverse effects were attributed to erythropoietin. While participating in the study, complications developed in 2 patients one in each group necessitating their removal from the study. Conclusion: We conclude that recombinant human erythropoietin increases the ability of the patients about to undergo elective surgery to donate autologous blood units.

  10. Clinical comparison of two commercial blood culture systems

    NARCIS (Netherlands)

    Spanjaard, L.; Kuijper, E. J.; Dankert, J.

    2000-01-01

    A prospective, volume-controlled comparison of the BacT/Alert FAN (Organon Teknika, USA) and Vital (bioMérieux, France) blood culture systems was performed in a university hospital during a period of 11 months. Twenty to 40 ml of blood drawn from an adult patient was distributed equally between a

  11. Evaluation of OneTouch Verio, a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littman, Karin; Petersen, Eva R.B.; Pussinen, Christel

    2013-01-01

    (ADA) quality goals. Blood samples were collected and measured on the OneTouch Verio® by laboratory personnel and patients with diabetes (n = 91, randomized into groups receiving personal training or mail instructions for the OneTouch Verio® system). Results were compared to a validated routine method......, imprecision and bias were calculated. User-friendliness was evaluated with a questionnaire. Results. Quality specifications for blood glucose concentration monitoring systems according to ISO 15197 were fulfilled. The mean coefficients of variation (CV%) of repeatability was 3.4% when tested by laboratory...... personnel and within the goal of imprecision suggested by ADA. Mean CV% of repeatability for patient self-monitoring was 5.0% and 5.1% in the training- and the mail group, respectively. Total error was 6.4-10.0%. The OneTouch Verio® showed no hematocrit interference or variation between strip lots...

  12. An Automatic Lab-on-Disc System for Blood Typing.

    Science.gov (United States)

    Chang, Yaw-Jen; Fan, Yi-Hua; Chen, Shia-Chung; Lee, Kuan-Hua; Lou, Liao-Yong

    2018-04-01

    A blood-typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This article presents a lab-on-disc blood-typing system to conduct a total of eight assays for a patient, including forward-typing tests, reverse-typing tests, and irregular-antibody tests. These assays are carried out in a microfluidic disc simultaneously. A blood-typing apparatus was designed to automatically manipulate the disc. The blood type can be determined by integrating the results of red blood cell (RBC) agglutination in the microchannels. The experimental results of our current 40 blood samples show that the results agree with those examined in the hospital. The accuracy reaches 97.5%.

  13. Social partners debate collective agreement system

    NARCIS (Netherlands)

    van het Kaar, R.

    2013-01-01

    Worries about levels of union membership have prompted debates on the collective bargaining system in the Netherlands. Governments have supported collective bargaining but the current Minister for Employment has stressed the need to enlarge the social base of the system and has sought advice from

  14. Pulmonary and systemic blood flow contributions to upper airways in canine lung

    International Nuclear Information System (INIS)

    Barman, S.A.; Ardell, J.L.; Parker, J.C.; Perry, M.L.; Taylor, A.E.

    1988-01-01

    The blood flow contributions and drainage patterns of the pulmonary and systemic circulations in the upper airways (trachea and main bronchi) were assessed in anesthetized dogs by injecting 15-μm radiolabeled microspheres into the right and left heart, respectively. After the animals were killed, the tracheal cartilage, tracheal muscle-mucosa, and main bronchi were excised. The tracheal cartilage and tracheal muscle-mucosa were divided into lower, middle, and upper segments for blood flow determinations. The pulmonary contribution to tracheal blood flow was very small, being higher in the lower segments. The systemic contribution to these same tracheal regions was significantly higher, and higher in the upper segments. The pulmonary and systemic circulations each contributed ∼50% to the main bronchi blood flow. The pulmonary blood flow contribution alone to the trachea and main bronchi was also determined in subsequent experiments that utilized the isolated lung, and these blood flows were not significantly different from the pulmonary contribution measured in the intact lungs. The present results indicate that the systemic (bronchial) circulation is the primary source of tracheal blood flow and that both the pulmonary and systemic circulations may contribute ∼50% of the blood flow to the main bronchi in dog lungs

  15. 40 CFR 35.925-13 - Sewage collection system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Sewage collection system. 35.925-13... Sewage collection system. That, if the project involves sewage collection system work, such work (a) is... existing or planned capacity to adequately treat such collected sewage. Replacement or major rehabilitation...

  16. Collectives and the design of complex systems

    CERN Document Server

    Wolpert, David

    2004-01-01

    Increasingly powerful computers are making possible distributed systems comprised of many adaptive and self-motivated computational agents. Such systems, when distinguished by system-level performance criteria, are known as "collectives." Collectives and the Design of Complex Systems lays the foundation for a science of collectives and describes how to design them for optimal performance. An introductory survey chapter is followed by descriptions of information-processing problems that can only be solved by the joint actions of large communities of computers, each running its own complex, decentralized machine-learning algorithm. Subsequent chapters analyze the dynamics and structures of collectives, as well as address economic, model-free, and control-theory approaches to designing complex systems. The work assumes a modest understanding of basic statistics and calculus. Topics and Features: Introduces the burgeoning science of collectives and its practical applications in a single useful volume Combines ap...

  17. Intraoperative evaluation of renal blood flow during laparoscopic partial nephrectomy with a novel Doppler system.

    Science.gov (United States)

    Mues, Adam C; Okhunov, Zhamshid; Badani, Ketan; Gupta, Mantu; Landman, Jaime

    2010-12-01

    Hemostasis remains a major challenge associated with laparoscopic renal surgery. We evaluated a cost-effective novel Doppler probe (DP) for assessment of vascular control during laparoscopic partial nephrectomy (LPN). We prospectively collected data during LPN procedures. We documented tumor location and size as well as subjective quality of the hilar dissection. The DP was compared with our standard intraoperative ultrasound system (SUS) for the ability to detect blood flow during hilar dissection and to determine parenchymal ischemia around the tumor after clamping of the renal vessels. Twenty patients underwent LPN by a single surgeon. The mean tumor size was 3.0 cm (range: 1.2-6.3 cm). The times to assess the kidney using the SUS and DP were 68.6 seconds (range: 20-155) and 44.5 seconds (range: 15-180), respectively. Evaluation prior to renal hilar clamping demonstrated the presence of blood flow in all 20 patients (100%) using the SUS and in 17 of 20 (85%) using the DP. Similarly, cessation of blood flow with clamping was documented in 100% of cases with SUS and 85% with DP. Persistent flow was detected by both SUS and DP in two patients requiring further dissection and reclamping. Then, both systems detected the absence of flow before tumor resection. With blood flow interruption confirmation, no patient had significant bleeding at the time of renal parenchymal transection. Intraoperative Doppler ultrasound technologies minimize the risk of significant bleeding during LPN. The DP is a small, simple, effective probe that can be used to assess blood flow interruption to the kidney during laparoscopic renal surgery.

  18. Regional integrated system of separated collection

    International Nuclear Information System (INIS)

    Markuskova, I.

    2008-01-01

    Since 2002 Palarikovo manages and ensures Regional integrated system of separated collection. In the present time 28 villages of the region are associated in Association of villages for sustainable treatment of municipal wastes with settlement in Palarikovo. In accordance with hierarchy of goals of national strategy in the field of treatment of municipal wastes the key aims of activity are centred on economical and sustainable treatment of municipal wastes, which consist in reduction of quantity and harmfulness of municipal wastes by destruction by unloading or combustion. The steps for achievement of this aim consist in (1) prevention of formation of wastes, (2) using of usable subjects (establishing of centre for repeated using in Regional collecting court), (3) by rigorous realisation of recycling program - by collection of separated commodities with a view to mainly material recycling as well as composting program. By starting of integrated regional system of separated collection were integrated 18 villages with 24,000 inhabitants into common separated collection. In the present time this association has 28 members (villages of the region) with total population 55,904. Operating of the Regional integrated system of separated collection in Palarikovo is reviewed

  19. Cortisol and prolactin concentrations during repeated blood sample collection from freely moving, mouse-sized mammals (Phodopus spp.).

    Science.gov (United States)

    Reburn, C J; Wynne-Edwards, K E

    2000-04-01

    Validation of a method for obtaining blood samples that does not change cortisol or prolactin concentrations yet allows serial blood samples to be collected from animals under anesthesia, without prior handling, from freely interacting social groups of small mammals. Results from five experiments are reported. Male dwarf hamsters (Phodopus spp.) were housed in modified home cages under continuous flow of compressed air that could be switched to isoflurane in O2 vehicle without approaching the cages. Dwarf hamsters respond to manual restraint with behavioral distress and increase in the concentration of the dominant glucocorticoid, cortisol, and decrease in prolactin concentration. Both effects are evident within one minute. In contrast, when this new method was used, neither cortisol nor prolactin changed in response to repeated sample collection (up to 8 successive samples at 2 hour intervals), prolonged isoflurane exposure, or substantial blood volume reduction (30%). Prolactin concentration was suppressed and cortisol concentration was increased in response to stimuli from other hamsters tested without anesthesia. Suppression of prolactin concentration was graded in response to the degree of stress and equaled the pharmacologic reduction caused by bromocryptine mesylate (50 microg of CB154 x 3 days). The technique is superior to alternatives for studies of behavioral endocrinology of freely interacting small mammals.

  20. Profiles of blood and blood component transfusion recipients in Zimbabwe

    Science.gov (United States)

    Mafirakureva, Nyashadzaishe; Khoza, Star; Hassall, Oliver; Faragher, Brian E.; Kajja, Isaac; Mvere, David A.; Emmanuel, Jean C.; Postma, Maarten J.; van Hulst, Marinus

    2015-01-01

    Background There are limited published data on the characteristics of blood transfusion recipients in sub-Saharan Africa. This study describes the demographic characteristics of blood transfusion recipients and patterns of blood and blood component use in Zimbabwe. Materials and methods Data on the characteristics of the blood transfusion recipients (age, sex, blood group), blood components received (type, quantity), discharge diagnoses and outcomes following transfusion (discharge status, duration of stay in hospital), were retrospectively collected from four major hospitals for the period from January 1, 2012 to December 31, 2012. Diagnoses were grouped into broad categories according to the disease headings of the International Classification of Diseases (ICD-10). Surgical procedures were grouped into broad categories according to organ system using ICD-9. Results Most of the 1,793 transfusion recipients studied were female (63.2%) and in the reproductive age group, i.e. 15–49 years (65.3%). The median age of the recipients was 33 years (range, 0–93). The majority of these recipients (n=1,642; 91.6%) received a red blood cell transfusion. The majority of the patients were diagnosed with conditions related to pregnancy and childbirth (22.3%), and diseases of blood and blood-forming organs (17.7%). The median time spent in hospital was 8 days (range, 0–214) and in-hospital mortality was 15.4%. Discussion Our sample of blood transfusion recipients were fairly young and most of them received red blood cell transfusions. The majority of patients in the reproductive age group received blood transfusions for pregnancy and childbirth-related diagnoses. PMID:26192782

  1. Waste collection systems for recyclables

    DEFF Research Database (Denmark)

    Larsen, Anna Warberg; Merrild, Hanna Kristina; Møller, Jacob

    2010-01-01

    and technical limitations are respected, and what will the environmental and economic consequences be? This was investigated in a case study of a municipal waste management system. Five scenarios with alternative collection systems for recyclables (paper, glass, metal and plastic packaging) were assessed...... and treatment of waste were reduced with increasing recycling, mainly because the high cost for incineration was avoided. However, solutions for mitigation of air pollution caused by increased collection and transport should be sought. (C) 2009 Elsevier Ltd. All rights reserved....

  2. Determination of Rate and Causes of Wastage of Blood and Blood Products in Iranian Hospitals

    Directory of Open Access Journals (Sweden)

    Rafat Mohebbi Far

    2014-06-01

    Full Text Available OBJECTIVE: The purpose of this study was to determine the rate and causes of wastage of blood and blood products (packed red cells, plasma, platelets, and cryoprecipitate in Qazvin hospitals. METHODS: The study was conducted in all hospitals in Qazvin, including 5 teaching hospitals, 2 social welfare hospitals, 3 private hospitals, 1 charity hospital, and 1 military hospital. This descriptive study was based on available data from hospital blood banks in the province of Qazvin. The research instrument was a 2-part questionnaire. The first part was related to demographic characteristics of hospitals and the second part elicited information about blood and blood component wastage. The collected data were then analyzed using descriptive statistic methods and SPSS 11.5. RESULTS: Blood wastage may occur for a number of reasons, including time expiry, wasted imports, blood medically or surgically ordered but not used, stock time expired, hemolysis, or miscellaneous reasons. Data indicated that approximately 77.9% of wasted pack cell units were wasted for the reason of time expiry. Pack cell wastage in hospitals is reported to range from 1.93% to 30.7%. Wastage at all hospitals averaged 9.8% among 30.913 issued blood products. Overall blood and blood product (packed red cells, plasma, platelets, and cryoprecipitate wastage was 3048 units and average total wastage per participant hospital for all blood groups was 254 units per year. CONCLUSION: Blood transfusion is an essential part of patient care. The blood transfusion system has made significant advancements in areas such as donor management, storage of blood, cross-matching, rational use of blood, and distribution. In order to improve the standards of blood banks and the blood transfusion services in Iran, comprehensive standards have been formulated to ensure better quality control in collection, storage, testing, and distribution of blood and its components for the identified major factors

  3. SBR-Blood: systems biology repository for hematopoietic cells.

    Science.gov (United States)

    Lichtenberg, Jens; Heuston, Elisabeth F; Mishra, Tejaswini; Keller, Cheryl A; Hardison, Ross C; Bodine, David M

    2016-01-04

    Extensive research into hematopoiesis (the development of blood cells) over several decades has generated large sets of expression and epigenetic profiles in multiple human and mouse blood cell types. However, there is no single location to analyze how gene regulatory processes lead to different mature blood cells. We have developed a new database framework called hematopoietic Systems Biology Repository (SBR-Blood), available online at http://sbrblood.nhgri.nih.gov, which allows user-initiated analyses for cell type correlations or gene-specific behavior during differentiation using publicly available datasets for array- and sequencing-based platforms from mouse hematopoietic cells. SBR-Blood organizes information by both cell identity and by hematopoietic lineage. The validity and usability of SBR-Blood has been established through the reproduction of workflows relevant to expression data, DNA methylation, histone modifications and transcription factor occupancy profiles. Published by Oxford University Press on behalf of Nucleic Acids Research 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  4. Relativistic collective diffusion in one-dimensional systems

    Science.gov (United States)

    Lin, Gui-Wu; Lam, Yu-Yiu; Zheng, Dong-Qin; Zhong, Wei-Rong

    2018-05-01

    The relativistic collective diffusion in one-dimensional molecular system is investigated through nonequilibrium molecular dynamics with Monte Carlo methods. We have proposed the relationship among the speed, the temperature, the density distribution and the collective diffusion coefficient of particles in a relativistic moving system. It is found that the relativistic speed of the system has no effect on the temperature, but the collective diffusion coefficient decreases to zero as the velocity of the system approaches to the speed of light. The collective diffusion coefficient is modified as D‧ = D(1 ‑w2 c2 )3 2 for satisfying the relativistic circumstances. The present results may contribute to the understanding of the behavior of the particles transport diffusion in a high speed system, as well as enlighten the study of biological metabolism at relativistic high speed situation.

  5. Comparison of two methods for blood lead analysis in cattle: graphite-furnace atomic absorption spectrometry and LeadCare(R) II system.

    Science.gov (United States)

    Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph

    2010-09-01

    The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.

  6. Can sibutramine alter systemic blood pressure in obese patients? Systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Hernani Pinto de Lemos Júnior

    Full Text Available CONTEXT: Systemic arterial hypertension is part of the metabolic syndrome resulting from obesity. OBJECTIVE: To evaluate the effect of sibutramine on overweight and obese patients' blood pressure through a systematic review. METHODS: All the studies included needed to be randomized controlled trials. The methodological quality of the selected trials was assessed using the criteria described in the Cochrane Handbook. The participants were overweight and obese patients; the intervention was sibutramine compared with placebo. The primary outcome measurement was systolic and diastolic blood pressure and the secondary measurement was blood pressure. Studies were identified by searching the following sources: Literatura Latino-Americana e do Caribe em Ciências da Saúde (Lilacs, Medline, Cochrane reviews, manual searches, personal communication and contact with the pharmaceutical industry. There were no language, date or other restrictions. Data collection and extraction was performed by two reviewers, who independently obtained the full articles of all eligible papers. RESULTS: Three meta-analyses were produced: 1 systolic blood pressure outcome (eight studies did not show statistical significance between sibutramine and placebo: weighted mean difference (WMD 1.57, confidence interval (CI -0.03 to 3.18; 2 diastolic blood pressure outcome (ten studies did not show statistical significance between sibutramine and placebo: WMD 1.13, CI -0.49 to 2.76; 3 blood pressure outcome (two studies also did not show statistical significance between the groups: relative risk (RR 0.69, CI 0.07 to 7.01. CONCLUSIONS: The meta-analyses presented in this systematic review show that sibutramine does not have a statistically significant effect on blood pressure, compared with placebo.

  7. Asymptotic tracking and disturbance rejection of the blood glucose regulation system.

    Science.gov (United States)

    Ashley, Brandon; Liu, Weijiu

    2017-07-01

    Type 1 diabetes patients need external insulin to maintain blood glucose within a narrow range from 65 to 108 mg/dl (3.6 to 6.0 mmol/l). A mathematical model for the blood glucose regulation is required for integrating a glucose monitoring system into insulin pump technology to form a closed-loop insulin delivery system on the feedback of the blood glucose, the so-called "artificial pancreas". The objective of this paper is to treat the exogenous glucose from food as a glucose disturbance and then develop a closed-loop feedback and feedforward control system for the blood glucose regulation system subject to the exogenous glucose disturbance. For this, a mathematical model for the glucose disturbance is proposed on the basis of experimental data, and then incorporated into an existing blood glucose regulation model. Because all the eigenvalues of the disturbance model have zero real parts, the center manifold theory is used to establish blood glucose regulator equations. We then use their solutions to synthesize a required feedback and feedforward controller to reject the disturbance and asymptotically track a constant glucose reference of 90  mg/dl. Since the regulator equations are nonlinear partial differential equations and usually impossible to solve analytically, a linear approximation solution is obtained. Our numerical simulations show that, under the linear approximate feedback and feedforward controller, the blood glucose asymptotically tracks its desired level of 90 mg/dl approximately. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Collective motion in quantum many-body systems

    Energy Technology Data Exchange (ETDEWEB)

    Haemmerling, Jens

    2011-06-07

    We study the emergence of collective dynamics in the integrable Hamiltonian system of two finite ensembles of coupled harmonic oscillators. After identification of a collective degree of freedom, the Hamiltonian is mapped onto a model of Caldeira-Leggett type, where the collective coordinate is coupled to an internal bath of phonons. In contrast to the usual Caldeira-Leggett model, the bath in the present case is part of the system. We derive an equation of motion for the collective coordinate which takes the form of a damped harmonic oscillator. We show that the distribution of quantum transition strengths induced by the collective mode is determined by its classical dynamics. This allows us to derive the spreading for the collective coordinate from first principles. After that we study the interplay between collective and incoherent single-particle motion in a model of two chains of particles whose interaction comprises a non-integrable part. In the perturbative regime, but for a general form of the interaction, we calculate the Fourier transform of the time correlation for the collective coordinate. We obtain the remarkable result that it always has a unique semi-classical interpretation. We show this by a proper renormalization procedure which also allows us to map the non-integrable system to the integrable model of Caldeira-Leggett-type considered previously in which the bath is part of the system.

  9. [Design of blood-pressure parameter auto-acquisition circuit].

    Science.gov (United States)

    Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A

    2000-02-01

    This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.

  10. Evaluation of Trapper-Collected Nobuto Filter-Paper Blood Samples for Distemper and Parvovirus Antibody Detection in Coyotes (Canis latrans) and Raccoons (Procyon lotor).

    Science.gov (United States)

    Kamps, Amanda J; Dubay, Shelli A; Langenberg, Julie; Maes, Roger K

    2015-07-01

    Blood samples are often collected from free-ranging wildlife for antibody detection. However, filter-paper (FP) strips are more cost efficient and easy to collect and store. We evaluated trapper-collected FP strips and body-cavity blood for canine distemper (CDV) and parvovirus (CPV-2) antibody detection in raccoons (Procyon lotor) and coyotes (Canis latrans). From 2008 to 2010, licensed trappers near Madison and Milwaukee, Wisconsin, US collected paired samples from harvested animals. Canine distemper antibodies were detected using virus neutralization and parvovirus antibodies were detected using hemagglutination inhibition. Titers ≥ 1:32 for CDV and ≥ 1:25 for CPV-2 were considered evidence of exposure. Using Cohen's kappa test of agreement, FP strip titers agreed with sera for CDV in coyotes (n = 28, K = 0.772) and raccoons (n = 29, K = 0.858) and for CPV-2 in coyotes (n = 40, K = 0.775) and raccoons (n = 70, K = 0.646). However, raccoons determined to be exposed to CPV-2 from sera were unexposed by FP strips in 35% of the samples. Titer results may be affected by quality and volume of blood samples, interval between collection and processing, small sample sizes, and diagnostic testing procedures. Filter-paper strips can be useful for detecting CDV and CPV-2 exposure in coyotes and raccoons with correct field sample collection and appropriate diagnostic testing procedures.

  11. IMPROVING SYSTEMS OF POWER COLLECTION OF THE MOSCOW MONORAIL TRANSPORT SYSTEM

    Directory of Open Access Journals (Sweden)

    O. A. Sydorov

    2010-01-01

    Full Text Available The disadvantages of existing current collection system for the Moscow monorail transport system are considered in the article. A new system differing in the contact geometry is proposed. Also the calculation of interaction of the offered current collection system based upon the Lagrange’s equations of second kind.

  12. Molecular DNA identification of blood sources fed on, for Culicine mosquitoes (Diptera: Culicidae collected in the Songkhla province, southern Thailand

    Directory of Open Access Journals (Sweden)

    Theerakamol Pengsakul

    2017-12-01

    Full Text Available Culicine mosquitoes are medically important vectors. Therefore, mosquito control measures are a crucial strategy to interrupt disease transmission. Collection of data on mosquito feeding patterns is crucial for developing an effective vector control strategy. The objective of this study was to use molecular biology methods to identify the sources of DNA in mosquito blood meals. The DNA from blood meals in the mosquito stomachs was extracted and amplified with multiplex PCR, using specific primer sets based on the mitochondrial cytochrome b gene, to identify the DNA sources among human, pig, goat, dog, cow, and chicken. Among the 297 mosquito samples collected in the Songkhla province of Thailand, in Aedes spp. mosquitoes the percentages positive for human, dog, pig, chicken, cow, a mixture of 2 vertebrate DNAs, or of 3, and negative (no identified DNA were 61.90, 2.38, 2.38, 0.60, 0.60, 4.18, 1.20 and 26.79% respectively. In Culex spp. blood meals the rank order was different: fractions positive for chicken, human, dog, cow, goat, pig, a mixture of 2 or 3 vertebrate DNAs, and negative were 40.83, 10.00, 5.00, 4.17, 1.67, 0.83, 8.32, 3.32 and 25.83% respectively. This study shows that feeding behaviors of the two species differ, with most Aedes spp. blood meals containing human blood, while Culex spp. had primarily consumed chicken blood. An improved understanding of the feeding behaviors of mosquitoes could contribute to new, more effective strategies for the control of mosquito populations.

  13. Astrocytic TYMP and VEGFA drive blood-brain barrier opening in inflammatory central nervous system lesions.

    Science.gov (United States)

    Chapouly, Candice; Tadesse Argaw, Azeb; Horng, Sam; Castro, Kamilah; Zhang, Jingya; Asp, Linnea; Loo, Hannah; Laitman, Benjamin M; Mariani, John N; Straus Farber, Rebecca; Zaslavsky, Elena; Nudelman, German; Raine, Cedric S; John, Gareth R

    2015-06-01

    In inflammatory central nervous system conditions such as multiple sclerosis, breakdown of the blood-brain barrier is a key event in lesion pathogenesis, predisposing to oedema, excitotoxicity, and ingress of plasma proteins and inflammatory cells. Recently, we showed that reactive astrocytes drive blood-brain barrier opening, via production of vascular endothelial growth factor A (VEGFA). Here, we now identify thymidine phosphorylase (TYMP; previously known as endothelial cell growth factor 1, ECGF1) as a second key astrocyte-derived permeability factor, which interacts with VEGFA to induce blood-brain barrier disruption. The two are co-induced NFκB1-dependently in human astrocytes by the cytokine interleukin 1 beta (IL1B), and inactivation of Vegfa in vivo potentiates TYMP induction. In human central nervous system microvascular endothelial cells, VEGFA and the TYMP product 2-deoxy-d-ribose cooperatively repress tight junction proteins, driving permeability. Notably, this response represents part of a wider pattern of endothelial plasticity: 2-deoxy-d-ribose and VEGFA produce transcriptional programs encompassing angiogenic and permeability genes, and together regulate a third unique cohort. Functionally, each promotes proliferation and viability, and they cooperatively drive motility and angiogenesis. Importantly, introduction of either into mouse cortex promotes blood-brain barrier breakdown, and together they induce severe barrier disruption. In the multiple sclerosis model experimental autoimmune encephalitis, TYMP and VEGFA co-localize to reactive astrocytes, and correlate with blood-brain barrier permeability. Critically, blockade of either reduces neurologic deficit, blood-brain barrier disruption and pathology, and inhibiting both in combination enhances tissue preservation. Suggesting importance in human disease, TYMP and VEGFA both localize to reactive astrocytes in multiple sclerosis lesion samples. Collectively, these data identify TYMP as an

  14. Performance evaluation of continuous blood sampling system for PET study. Comparison of three detector-systems

    CERN Document Server

    Matsumoto, K; Sakamoto, S; Senda, M; Yamamoto, S; Tarutani, K; Minato, K

    2002-01-01

    To measure cerebral blood flow with sup 1 sup 5 O PET, it is necessary to measure the time course of arterial blood radioactivity. We examined the performance of three different types of continuous blood sampling system. Three kinds of continuous blood sampling system were used: a plastic scintillator-based beta detector (conventional beta detector (BETA)), a bismuth germinate (BGO)-based coincidence gamma detector (Pico-count flow-through detector (COINC)) and a Phoswich detector (PD) composed by a combination of plastic scintillator and BGO scintillator. Performance of these systems was evaluated for absolute sensitivity, count rate characteristic, sensitivity to background gamnra photons, and reproducibility for nylon tube geometry. The absolute sensitivity of the PD was 0.21 cps/Bq for sup 6 sup 8 Ga positrons at the center of the detector. This was approximately three times higher than BETA, two times higher than COINC. The value measured with BETA was stable, even when background radioactivity was incre...

  15. The post-occipital spinal venous sinus of the Nile crocodile (Crocodylus niloticus: Its anatomy and use for blood sample collection and intravenous infusions

    Directory of Open Access Journals (Sweden)

    Jan G. Myburgh

    2014-05-01

    Full Text Available The post-occipital sinus of the spinal vein is often used for the collection of blood samples from crocodilians. Although this sampling method has been reported for several crocodilian species, the technique and associated anatomy has not been described in detail in any crocodilian, including the Nile crocodile (Crocodylus niloticus. The anatomy of the cranial neck region was investigated macroscopically, microscopically, radiographically and by means of computed tomography. Latex was injected into the spinal vein and spinal venous sinus of crocodiles to visualise the regional vasculature. The spinal vein ran within the vertebral canal, dorsal to and closely associated with the spinal cord and changed into a venous sinus cranially in the post-occipital region. For blood collection, the spinal venous sinus was accessed through the interarcuate space between the atlas and axis (C1 and C2 by inserting a needle angled just off the perpendicular in the midline through the craniodorsal cervical skin, just cranial to the cranial borders of the first cervical osteoderms. The most convenient method of blood collection was with a syringe and hypodermic needle. In addition, the suitability of the spinal venous sinus for intravenous injections and infusions in live crocodiles was evaluated. The internal diameter of the commercial human epidural catheters used during these investigations was relatively small, resulting in very slow infusion rates. Care should be taken not to puncture the spinal cord or to lacerate the blood vessel wall using this route for blood collection or intravenous infusions.

  16. An implantable centrifugal blood pump with a recirculating purge system (Cool-Seal system).

    Science.gov (United States)

    Yamazaki, K; Litwak, P; Tagusari, O; Mori, T; Kono, K; Kameneva, M; Watach, M; Gordon, L; Miyagishima, M; Tomioka, J; Umezu, M; Outa, E; Antaki, J F; Kormos, R L; Koyanagi, H; Griffith, B P

    1998-06-01

    A compact centrifugal blood pump has been developed as an implantable left ventricular assist system. The impeller diameter is 40 mm, and pump dimensions are 55 x 64 mm. This first prototype, fabricated from titanium alloy, resulted in a pump weight of 400 g including a brushless DC motor. The weight of a second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon (DLC) to improve blood compatibility. Flow rates of over 7 L/min against 100 mm Hg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system (Cool-Seal) is used for the shaft seal. In this seal system, the seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. Purge fluid is continuously purified and sterilized by an ultrafiltration unit which is incorporated in the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular (LV) apex descending aorta bypass was performed utilizing an expanded polytetrafluoroethylene (ePTFE) vascular graft with the pump placed in the left thoracic cavity. In 2 in vivo experiments, the pump flow rate was maintained at 5-9 L/min, and pump power consumption remained stable at 9-10 W. All plasma free Hb levels were measured at less than 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (<0.5 ml/day). In both calves, the pumps demonstrated trouble free continuous function over 6 month (200 days and 222 days).

  17. [Blood groups - minuses and pluses. Do the blood group antigens protect us from infectious diseases?].

    Science.gov (United States)

    Czerwiński, Marcin

    2015-06-25

    Human blood can be divided into groups, which is a method of blood classification based on the presence or absence of inherited erythrocyte surface antigens that can elicit immune response. According to the International Society of Blood Transfusion, there are 341 blood group antigens collected in 35 blood group systems. These antigens can be proteins, glycoproteins or glycosphingolipids, and function as transmembrane transporters, ion channels, adhesion molecules or receptors for other proteins. The majority of blood group antigens is present also on another types of cells. Due to their localization on the surface of cells, blood group antigens can act as receptors for various pathogens or their toxins, such as protozoa (malaria parasites), bacteria (Helicobacter pylori, Vibrio cholerae and Shigella dysenteriae) and viruses (Noroviruses, Parvoviruses, HIV). If the presence of group antigen (or its variant which arised due to mutation) is beneficial for the host (e.g. because pathogens are not able to bind to the cells), the blood group may become a selection trait, leading to its dissemination in the population exposed to that pathogen. There are thirteen blood group systems that can be related to pathogen resistance, and it seems that the particular influence was elicit by malaria parasites. It is generally thought that the high incidence of blood groups such as O in the Amazon region, Fy(a-b-) in Africa and Ge(-) in Papua-New Guinea is the result of selective pressure from malaria parasite. This review summarizes the data about relationship between blood groups and resistance to pathogens.

  18. A system for oxygen-15 labeled blood for medical applications

    International Nuclear Information System (INIS)

    Subramanyam, R.; Bucelewicz, W.M.; Hoop, B. Jr.; Jones, S.C.

    1977-01-01

    Oxygen-15 labeled compounds in blood have been used successfully for cerebral circulation and cerebral oxygen metabolism measurements. The present paper describes a system for the rapid sequential production of 15 O-HgB, C 15 O-Hgb and H 2 15 O in blood under sterile and pyrogen-free conditions. A tonometer has been adopted for labeling blood without hemolysis and foam production. (author)

  19. Effects of Clove Oil as a Euthanasia Agent on Blood Collection Efficiency and Serum Cortisol Levels in Danio rerio.

    Science.gov (United States)

    Davis, Daniel J; Klug, Jenna; Hankins, Miriam; Doerr, Holly M; Monticelli, Stephanie R; Song, Ava; Gillespie, Catherine H; Bryda, Elizabeth C

    2015-09-01

    Zebrafish are an important laboratory animal model for biomedical research and are increasingly being used for behavioral neuroscience. Tricaine methanesulfonate (MS222) is the standard agent used for euthanasia of zebrafish. However, recent studies of zebrafish behavior suggest that MS222 may be aversive, and clove oil might be a possible alternative. In this study, we compared the effects of MS222 or clove oil as a euthanasia agent in zebrafish on the volume of blood collected and on serum levels of cortisol. Greater amounts of serum could be collected and lower serum levels of cortisol were present in fish euthanized with clove oil compared with equipotent dose of MS222. Euthanasia with clove oil did not blunt the expected elevation of serum cortisol levels elicited by an acute premortem stress. According to our findings, clove oil is a fast-acting agent that minimizes the cortisol response to euthanasia in zebrafish and allows the collection of large volumes of blood postmortem. These results represent a significant refinement in euthanasia methods for zebrafish.

  20. Maternal systemic or cord blood inflammation is associated with birth anthropometry in a Tanzanian prospective cohort.

    Science.gov (United States)

    Wilkinson, A L; Pedersen, S H; Urassa, M; Michael, D; Andreasen, A; Todd, J; Kinung'hi, S M; Changalucha, J; McDermid, J M

    2017-01-01

    HIV infection is associated with chronic systemic inflammation, with or without antiretroviral therapy. Consequences for foetal growth are not understood, particularly in settings where multiple maternal infections and malnutrition are common. The study was designed to examine maternal systemic circulating and umbilical cord blood cytokine concentrations in relation to birth anthropometry in a Tanzanian prospective cohort. A 9-plex panel of maternal plasma cytokines in HIV-positive (n = 44) and HIV-negative (n = 70) mothers and the same cytokines in umbilical cord blood collected at delivery was assayed. Linear regression modelled associations between maternal or cord blood cytokines and birth anthropometry. Health indicators (haemoglobin, mid-upper-arm circumference, body mass index) in HIV-positive mothers without considerable immunosuppression did not differ from HIV-negative women. Despite this, HIV-exposed infants had lower birthweight and length. Subgroup analyses indicated that HIV management using HAART was associated with lower plasma TNF-α, as were longer durations of any antiretroviral therapy (≥2 months). Greater maternal plasma TNF-α was associated with earlier delivery (-1.7 weeks, P = 0.039) and lower birthweights (-287 g; P = 0.020), while greater umbilical cord TNF-α (-1.43 cm; P = 0.036) and IL-12p70 (-2.4 cm; P = 0.008) were associated with shorter birth length. Birthweight was inversely associated with cord IL-12p70 (-723 g; P = 0.001) and IFN-γ (-482 g, P = 0.007). Maternal cytokines during pregnancy did not correlate with umbilical cord cytokines at delivery. Systemic inflammation identified in maternal plasma or umbilical cord blood was associated with poorer birth anthropometrics in HIV-exposed and HIV-unexposed infants. Controlling maternal and/or foetal systemic inflammation may improve birth anthropometry. © 2016 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  1. Code development of the national hemovigilance system and expansion strategies for hospital blood banks

    Directory of Open Access Journals (Sweden)

    Kim Jeongeun

    2012-01-01

    Full Text Available Objectives : The aims of this study were to develop reportable event codes that are applicable to the national hemovigilance systems for hospital blood banks, and to present expansion strategies for the blood banks. Materials and Methods : The data were obtained from a literature review and expert consultation, followed by adding to and revising the established hemovigilance code system and guidelines to develop reportable event codes for hospital blood banks. The Medical Error Reporting System-Transfusion Medicine developed in the US and other codes of reportable events were added to the Korean version of the Biologic Products Deviation Report (BPDR developed by the Korean Red Cross Blood Safety Administration, then using these codes, mapping work was conducted. We deduced outcomes suitable for practice, referred to the results of the advisory councils, and conducted a survey with experts and blood banks practitioners. Results : We developed reportable event codes that were applicable to hospital blood banks and could cover blood safety - from blood product safety to blood transfusion safety - and also presented expansion strategies for hospital blood banks. Conclusion : It was necessary to add 10 major categories to the blood transfusion safety stage and 97 reportable event codes to the blood safety stage. Contextualized solutions were presented on 9 categories of expansion strategies of hemovigilance system for the hospital blood banks.

  2. Field Evaluation of Capillary Blood Samples as a Collection Specimen for the Rapid Diagnosis of Ebola Virus Infection During an Outbreak Emergency.

    Science.gov (United States)

    Strecker, Thomas; Palyi, Bernadett; Ellerbrok, Heinz; Jonckheere, Sylvie; de Clerck, Hilde; Bore, Joseph Akoi; Gabriel, Martin; Stoecker, Kilian; Eickmann, Markus; van Herp, Michel; Formenty, Pierre; Di Caro, Antonino; Becker, Stephan

    2015-09-01

    Reliable reverse transcription polymerase chain reaction (RT-PCR)-based diagnosis of Ebola virus infection currently requires a blood sample obtained by intravenous puncture. During the current Ebola outbreak in Guinea, we evaluated the usability of capillary blood samples collected from fingersticks of patients suspected of having Ebola virus disease (EVD) for field diagnostics during an outbreak emergency. A total of 120 venous and capillary blood samples were collected from 53 patients admitted to the Ebola Treatment Centre in Guéckédou, Guinea, between July and August 2014. All sample specimens were analyzed by RT-PCR using the RealStar Filovirus Screen RT-PCR Kit 1.0 from altona Diagnostics (Germany). We compared samples obtained by venipuncture and those obtained by capillary blood sampling absorbed onto swab devices. The resulting sensitivity and specificity of tests performed with capillary blood samples were 86.8% (95% confidence interval [CI], 71.9%-95.6%; 33/38 patients) and 100% (95% CI, 84.6%-100%; 22/22 patients), respectively. Our data suggest that capillary blood samples could serve as an alternative to venous blood samples for the diagnosis of EVD in resource-limited settings during a crisis. This can be of particular advantage in cases when venipuncture is difficult to perform-for example, with newborns and infants or when adult patients reject venipuncture for cultural or religious reasons. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America.

  3. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  4. A novel system for providing compatible blood to patients during surgery: "self-service" electronic blood banking by nursing staff.

    Science.gov (United States)

    Cheng, G; Chiu, D S; Chung, A S; Wong, H F; Chan, M W; Lui, Y K; Choy, F M; Chan, J C; Chan, A H; Lam, S T; Fan, T C

    1996-04-01

    A good blood bank must be able to provide compatible blood units promptly to operating room patients with minimal wastage. A "self-service" by nursing staff blood banking system that is safe, efficient, and well-accepted has been developed. Specific blood units are no longer assigned to surgical patients who have a negative pretransfusion antibody screen, irrespective of the type of surgery. A computer-generated list of the serial numbers of all group-identical blood units currently in the blood bank inventory is provided for each patient. The units themselves are not labeled with a patient's name. The group O list will be provided for group O patients, the group A list for group A patients, and so forth. Should the patient require transfusion during surgery, the operating room nurses go to the refrigerator, remove any group-identical unit, and check the serial number of the unit against the serial numbers on the patient's list. If the serial number is on that list, the blood bank will accept responsibility for compatibility. The system was implemented in 1995. Since implementation, a total of 2154 patients have undergone operations at this hospital. Thirty-two patients received more than 10 units of red cells each. There were no transfusion errors. The crossmatch-to-transfusion ratio was reduced from 1.67 to 1.12. Turnaround time for supplying additional or urgent units to patients in operating room was shortened from 33 to 2.5 minutes. There was no incidence of a blood unit's serial number not being on the list. Work by nurses and technical staff was reduced by nearly 50 percent. The "self-service" (by nursing staff) blood banking system described is safe and efficient. It saves staff time and can be easily set up.

  5. Circulating Blood eNOS Contributes to the Regulation of Systemic Blood Pressure and Nitrite Homeostasis

    Science.gov (United States)

    Wood, Katherine C.; Cortese-Krott, Miriam M.; Kovacic, Jason C.; Noguchi, Audrey; Liu, Virginia B.; Wang, Xunde; Raghavachari, Nalini; Boehm, Manfred; Kato, Gregory J.; Kelm, Malte; Gladwin, Mark T.

    2013-01-01

    Objective Mice genetically deficient in endothelial nitric oxide synthase (eNOS−/−) are hypertensive with lower circulating nitrite levels, indicating the importance of constitutively produced nitric oxide (NO•) to blood pressure regulation and vascular homeostasis. While the current paradigm holds that this bioactivity derives specifically from expression of eNOS in endothelium, circulating blood cells also express eNOS protein. A functional red cell eNOS that modulates vascular NO• signaling has been proposed. Approach and Results To test the hypothesis that blood cells contribute to mammalian blood pressure regulation via eNOS-dependent NO• generation, we cross-transplanted WT and eNOS−/− mice, producing chimeras competent or deficient for eNOS expression in circulating blood cells. Surprisingly, we observed a significant contribution of both endothelial and circulating blood cell eNOS to blood pressure and systemic nitrite levels, the latter being a major component of the circulating NO• reservoir. These effects were abolished by the NOS inhibitor L-NAME and repristinated by the NOS substrate L-Arginine, and were independent of platelet or leukocyte depletion. Mouse erythrocytes were also found to carry an eNOS protein and convert 14C-Arginine into 14C-Citrulline in a NOS-dependent fashion. Conclusions These are the first studies to definitively establish a role for a blood borne eNOS, using cross transplant chimera models, that contributes to the regulation of blood pressure and nitrite homeostasis. This work provides evidence suggesting that erythrocyte eNOS may mediate this effect. PMID:23702660

  6. Blood and dried blood spot telomere length measurement by qPCR: assay considerations.

    Directory of Open Access Journals (Sweden)

    DeAnna L Zanet

    Full Text Available Measurement of telomere length is crucial for the study of telomere maintenance and its role in molecular pathophysiology of diseases and in aging. Several methods are used to measure telomere length, the choice of which usually depends on the type and size of sample to be assayed, as well as cost and throughput considerations. The goal of this study was to investigate the factors that may influence the reliability of qPCR-based relative telomere length measurements in whole blood. Day to day intra-individual variability, types of blood anticoagulant, sample storage conditions, processing and site of blood draw were investigated. Two qPCR-based methods to measure telomere length (monoplex vs. multiplex were also investigated and showed a strong correlation between them. Freezing and thawing of the blood and storage of the blood at 4°C for up to 4 days did not affect telomere length values. Telomere lengths in dried blood spots were significantly higher than both whole blood and peripheral mononuclear blood cells, and were highly correlated with both. We found that telomere length measurements were significantly higher in dried blood spots collected directly from fingertip prick compared to dried blood spots prepared with anticoagulated whole blood collected from the finger, and non-blotted whole blood taken from both finger and arm venipuncture. This suggests that DNA from cells blotted on paper is not equivalent to that collected from venipuncture whole blood, and caution should be taken when comparing between blood sample types.

  7. Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

    Science.gov (United States)

    Choi, Qute; Kim, Hyun Jin; Kim, Jong Wan; Kwon, Gye Cheol; Koo, Sun Hoe

    2018-01-04

    The process of plate streaking has been automated to improve routine workflow of clinical microbiology laboratories. Although there were many evaluation reports about the inoculation of various body fluid samples, few evaluations have been reported for blood. In this study, we evaluated the performance of automated inoculating system, Previ Isola for various routine clinical samples including blood. Blood culture, body fluid, and urine samples were collected. All samples were inoculated on both sheep blood agar plate (BAP) and MacConkey agar plate (MCK) using Previ Isola and manual method. We compared two methods in aspect of quality and quantity of cultures, and sample processing time. To ensure objective colony counting, an enumeration reading reference was made through a preliminary experiment. A total of 377 nonduplicate samples (102 blood culture, 203 urine, 72 body fluid) were collected and inoculated. The concordance rate of quality was 100%, 97.0%, and 98.6% in blood, urine, and other body fluids, respectively. In quantitative aspect, it was 98.0%, 97.0%, and 95.8%, respectively. The Previ Isola took a little longer to inoculate the specimen than manual method, but the hands-on time decreased dramatically. The shortened hands-on time using Previ Isola was about 6 minutes per 10 samples. We demonstrated that the Previ Isola showed high concordance with the manual method in the inoculation of various body fluids, especially in blood culture sample. The use of Previ Isola in clinical microbiology laboratories is expected to save considerable time and human resources. © 2018 Wiley Periodicals, Inc.

  8. Efficient collection of peripheral blood stem cells using the Fresenius AS104 in chronic myelocytic leukemia patients with very high numbers of platelets.

    Science.gov (United States)

    Komatsu, F; Ishida, Y

    1997-04-01

    For chronic myelocytic leukemia patients with very high numbers of platelets, we describe an efficient method for the collection of peripheral blood stem cells (PBSC) using the Fresenius AS104 cell separator. In these patients, it is difficult to collect a sufficient number of PBSC, due to the platelet band interfering with the machine's red cell interface sensor. We, therefore, tried a manual adjustment of the device. The collection phase was set automatically. When the whole blood began to separate into the red cell layer and plasma (plus mononuclear cell) layer, the red cell interface setting of "7:1" was changed to "OFF," and the plasma pump flow rate was controlled manually in order to locate the interface position 1 cm from the outside wall of the centrifuge chamber. After the collection phase, the procedure was returned to the automatic setting. By repeating this procedure, we were able to collect large numbers of PBSC.

  9. Photovoltaic Thermal panels in collective thermal solar systems

    International Nuclear Information System (INIS)

    Elswijk, M.J.; Strootman, K.J.; Jong, M.J.M.; De Lange, E.T.N.; Smit, W.F.

    2003-12-01

    A feasibility study has been carried out to assess the options to apply photovoltaic/thermal panels (PVT-panels) in collective solar thermal systems in urban areas in the Netherlands. The study was focused on the technical (architecture and installations) and the economical feasibility of collective PVT-systems in comparison with conventional solar thermal systems and combinations of photovoltaic (PV) panels and solar collectors. The results of the study also give insight into cost and the market for PVT-panels. Three case studies in which collective solar collector systems were applied are analyzed again by simulating the installation of a PVT-panels system and a separate solar thermal PV system [nl

  10. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... resource to help stay current with the latest advances in the field Hematology 2017 A collection of articles ... Disorders Blood Cancers Blood Clots Blood Clotting and Pregnancy Clots and ...

  11. User Performance Evaluation of Four Blood Glucose Monitoring Systems Applying ISO 15197:2013 Accuracy Criteria and Calculation of Insulin Dosing Errors.

    Science.gov (United States)

    Freckmann, Guido; Jendrike, Nina; Baumstark, Annette; Pleus, Stefan; Liebing, Christina; Haug, Cornelia

    2018-04-01

    The international standard ISO 15197:2013 requires a user performance evaluation to assess if intended users are able to obtain accurate blood glucose measurement results with a self-monitoring of blood glucose (SMBG) system. In this study, user performance was evaluated for four SMBG systems on the basis of ISO 15197:2013, and possibly related insulin dosing errors were calculated. Additionally, accuracy was assessed in the hands of study personnel. Accu-Chek ® Performa Connect (A), Contour ® plus ONE (B), FreeStyle Optium Neo (C), and OneTouch Select ® Plus (D) were evaluated with one test strip lot. After familiarization with the systems, subjects collected a capillary blood sample and performed an SMBG measurement. Study personnel observed the subjects' measurement technique. Then, study personnel performed SMBG measurements and comparison measurements. Number and percentage of SMBG measurements within ± 15 mg/dl and ± 15% of the comparison measurements at glucose concentrations performed by lay-users. The study was registered at ClinicalTrials.gov (NCT02916576). Ascensia Diabetes Care Deutschland GmbH.

  12. The data collection system for failure/maintenance at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Casey, M.A.; Gruetzmacher, K.M.; Bartlit, J.R.; Cadwallader, L.C.

    1988-01-01

    A data collection system for obtaining information which can be used to help determine the reliability and vailability of future fusion power plants has been installed at the Los Alamos National Laboratory's Tritium Systems Test Assembly (TSTA). Failure and maintenance data on components of TSTA's tritium systems have been collected since 1984. The focus of the data collection has been TSTA's Tritium Waste Tratment System (TWT), which has maintained high availability since it became operation in 1982. Data collection is still in progress and a total of 291 failure reports are in the data collection system at this time, 47 of which are from the TWT. 6 refs., 2 figs., 2 tabs

  13. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

    Science.gov (United States)

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-12-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery-powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring.

  14. Using an integrated automated system to optimize retention and increase frequency of blood donations.

    Science.gov (United States)

    Whitney, J Garrett; Hall, Robert F

    2010-07-01

    This study examines the impact of an integrated, automated phone system to reinforce retention and increase frequency of donations among blood donors. Cultivated by incorporating data results over the past 7 years, the system uses computerized phone messaging to contact blood donors with individualized, multilevel notifications. Donors are contacted at planned intervals to acknowledge and recognize their donations, informed where their blood was sent, asked to participate in a survey, and reminded when they are eligible to donate again. The report statistically evaluates the impact of the various components of the system on donor retention and blood donations and quantifies the fiscal advantages to blood centers. By using information and support systems provided by the automated services and then incorporating the phlebotomists and recruiters to reinforce donor retention, both retention and donations will increase. © 2010 American Association of Blood Banks.

  15. Cold Vacuum Drying Facility Condensate Collection System Design Description. System 19

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    2000-01-01

    The Cold Vacuum Drying (CVD) Facility of Spent Nuclear Fuel (SNF) provides required process systems, supporting equipment, and facilities to support the SNF Project mission. This system design description (SDD) addresses the Condensate Collection System (CCS). This is a general service system. The CCS begins at the condensate outlet of the general process air-handling unit (AHU) and the condensate outlets for the active process bays AHUs. The system terminates at each condensate collection tank (5 total)

  16. Logistics systems for recycling - Efficient collection of household waste

    Energy Technology Data Exchange (ETDEWEB)

    Jahre, M

    1996-12-31

    This dissertation investigates collection and recycling of household waste with focus on packaging materials. The purpose is how to describe and explain the design of a collection system according to different system environments in order to achieve high logistics performance in terms of low cost and high service. The research approach consists of two main parts. First, data on existing systems are collected and analyzed. Then a model is used to analyze cost consequences from changes in the system and the environment. Four main properties of reverse distribution channels were identified including the number of distribution levels and distribution points, whether the system is bring or kerbside, the degree of separation at source and the degree of co-collection. The study further demonstrates that performance can be measured in a number of ways including service toward end-markets and households, costs, environmental consequences and programme ratios. Finally, two main environmental factors identified were population density and the number of materials being collected in the system. The major conclusion from the study is that systems in areas with low population density should collect and recycle few materials that should be separated at the source and then co-collected. Systems in areas with high population density, on the other hand, may collect many materials, but then centralized separation (i.e. processing in a MRF) should take place. 103 refs, 72 figs, 65 tabs

  17. Logistics systems for recycling - Efficient collection of household waste

    Energy Technology Data Exchange (ETDEWEB)

    Jahre, M.

    1995-12-31

    This dissertation investigates collection and recycling of household waste with focus on packaging materials. The purpose is how to describe and explain the design of a collection system according to different system environments in order to achieve high logistics performance in terms of low cost and high service. The research approach consists of two main parts. First, data on existing systems are collected and analyzed. Then a model is used to analyze cost consequences from changes in the system and the environment. Four main properties of reverse distribution channels were identified including the number of distribution levels and distribution points, whether the system is bring or kerbside, the degree of separation at source and the degree of co-collection. The study further demonstrates that performance can be measured in a number of ways including service toward end-markets and households, costs, environmental consequences and programme ratios. Finally, two main environmental factors identified were population density and the number of materials being collected in the system. The major conclusion from the study is that systems in areas with low population density should collect and recycle few materials that should be separated at the source and then co-collected. Systems in areas with high population density, on the other hand, may collect many materials, but then centralized separation (i.e. processing in a MRF) should take place. 103 refs, 72 figs, 65 tabs

  18. Colour coding for blood collection tube closures - a call for harmonisation.

    Science.gov (United States)

    Simundic, Ana-Maria; Cornes, Michael P; Grankvist, Kjell; Lippi, Giuseppe; Nybo, Mads; Ceriotti, Ferruccio; Theodorsson, Elvar; Panteghini, Mauro

    2015-02-01

    At least one in 10 patients experience adverse events while receiving hospital care. Many of the errors are related to laboratory diagnostics. Efforts to reduce laboratory errors over recent decades have primarily focused on the measurement process while pre- and post-analytical errors including errors in sampling, reporting and decision-making have received much less attention. Proper sampling and additives to the samples are essential. Tubes and additives are identified not only in writing on the tubes but also by the colour of the tube closures. Unfortunately these colours have not been standardised, running the risk of error when tubes from one manufacturer are replaced by the tubes from another manufacturer that use different colour coding. EFLM therefore supports the worldwide harmonisation of the colour coding for blood collection tube closures and labels in order to reduce the risk of pre-analytical errors and improve the patient safety.

  19. [Absolute numbers of peripheral blood CD34+ hematopoietic stem cells prior to a leukapheresis procedure as a parameter predicting the efficiency of stem cell collection].

    Science.gov (United States)

    Galtseva, I V; Davydova, Yu O; Gaponova, T V; Kapranov, N M; Kuzmina, L A; Troitskaya, V V; Gribanova, E O; Kravchenko, S K; Mangasarova, Ya K; Zvonkov, E E; Parovichnikova, E N; Mendeleeva, L P; Savchenko, V G

    To identify a parameter predicting a collection of at least 2·106 CD34+ hematopoietic stem cells (HSC)/kg body weight per leukapheresis (LA) procedure. The investigation included 189 patients with hematological malignancies and 3 HSC donors, who underwent mobilization of stem cells with their subsequent collection by LA. Absolute numbers of peripheral blood leukocytes and CD34+ cells before a LA procedure, as well as a number of CD34+ cells/kg body weight (BW) in the LA product stored on the same day were determined in each patient (donor). There was no correlation between the number of leukocytes and that of stored CD34+ cells/kg BW. There was a close correlation between the count of peripheral blood CD34+ cells prior to LA and that of collected CD34+ cells calculated with reference to kg BW. The optimal absolute blood CD34+ cell count was estimated to 20 per µl, at which a LA procedure makes it possible to collect 2·106 or more CD34+ cells/kg BW.

  20. How Should Blood Glucose Meter System Analytical Performance Be Assessed?

    Science.gov (United States)

    Simmons, David A

    2015-08-31

    Blood glucose meter system analytical performance is assessed by comparing pairs of meter system and reference instrument blood glucose measurements measured over time and across a broad array of glucose values. Consequently, no single, complete, and ideal parameter can fully describe the difference between meter system and reference results. Instead, a number of assessment tools, both graphical (eg, regression plots, modified Bland-Altman plots, and error grid analysis) and tabular (eg, International Organization for Standardization guidelines, mean absolute difference, and mean absolute relative difference) have been developed to evaluate meter system performance. The strengths and weaknesses of these methods of presenting meter system performance data, including a new method known as Radar Plots, are described here. © 2015 Diabetes Technology Society.

  1. Environmental-benefit analysis of two urban waste collection systems

    International Nuclear Information System (INIS)

    Aranda Usón, Alfonso; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-01-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO 2 emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO 2 -eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. - Highlights: • A comprehensive

  2. Environmental-benefit analysis of two urban waste collection systems

    Energy Technology Data Exchange (ETDEWEB)

    Aranda Usón, Alfonso, E-mail: alaranda@unizar.es; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-10-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO{sub 2} emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO{sub 2}-eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. - Highlights: • A

  3. Portable regional cerebral blood flow system based on IBM PC/AT and microprocessor electronics

    International Nuclear Information System (INIS)

    Mun, S.K.; Mun, I.K.; Petite, J.; Cohan, S.L.; Fahey, F.H.

    1986-01-01

    A portable 16-channel reginal cerebral blood flow (rCBF) measuring system has been developed using an IBM PC/AT and new microelectronics to improve processing speed and portability. The detector electronics were developed by Scan Detectronics A/S of Denmark. The counter module contains 18 16-bit counters, each programmable in four different modes. The rate meter has three independent microprocessor controllers for rate meter functions, window controller, and channel controller. The detector electronics and detection parameters can be fully controlled by the host PC/AT. The menu-driven system (Better Basic) assists the operator at each step. The collected data from 16 channels can be processed automatically or postprocessed using more flexible and sophisticated techniques within 20 minutes. The headgear holding 16 sodium iodide detectors is fabricated by modifying a motorcycle helmet

  4. Collective motion in behaviorally heterogeneous systems

    OpenAIRE

    Copenhagen, Katherine

    2017-01-01

    Collective motion is a widespread phenomenon in nature where individuals actively propel themselves, gather together and move as a group. Some examples of collective motion are bird flocks, fish schools, bacteria swarms, cell clusters, and crowds of people. Many models seek to understand the effects of activity in collective systems including things such as environmental disorder, density, and interaction details primarily at infinite size limits and with uniform populations. In this disserta...

  5. Influence of partial pressure of oxygen in blood samples on measurement performance in glucose-oxidase-based systems for self-monitoring of blood glucose.

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-11-01

    Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Aliquots of 20 venous samples were adjusted to the following pO2 values: oxygen sensitive. © 2013 Diabetes Technology Society.

  6. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  7. 76 FR 45262 - Agency Information Collection Activities; Proposed Collection; Comment Request; Current Good...

    Science.gov (United States)

    2011-07-28

    ... notification, and ``lookback.'' DATES: Submit either electronic or written comments on the collection of information by September 26, 2011. ADDRESSES: Submit electronic comments on the collection of information to... blood components are drugs under the FD&C Act, blood and plasma establishments must comply with the...

  8. Peripheral blood stem cell collection for allogeneic hematopoietic stem cell transplantation: Practical implications after 200 consequent transplants.

    Science.gov (United States)

    Goren Sahin, Deniz; Arat, Mutlu

    2017-12-01

    Proper stem cell mobilization is one of the most important steps in hematopoietic stem cell transplantation (HSCT). The aim of this paper is to share our 6 years' experience and provide practical clinical approaches particularly for stem cell mobilization and collection within the series of more than 200 successive allogeneic HSCT at our transplant center. Two hundred and seven consecutive patients who underwent allogeneic peripheral blood stem cell transplantation were included in this study. Age, sex, weight, complete blood counts, CD34 + cell counts, total collected amount of CD34 + cells, CD34 + cells per 10l processed, mobilization failure and adverse events were reviewed. Median age was 40.2±12.9 (21-68) years and 46.4±13.4 (17-67) years for donors and patients, respectively. The number of donors who had undergone adequate CD34 + cell harvesting and completed the procedure on the fourth day was 67 (32.8% of all patients). Only 12 patients required cell apheresis both on day 5 and 6. Apheresis was completed on day 4 and/or day 5 in 94.2% of all our donors. There was no significant association between CD34 + stem cell volume and age, gender and weight values of donors. Mobilization failure was not seen in our series. G-CSF is highly effective in 1/3 of the donors on the 4th day in order to collect enough number of stem cells. We propose that peripheral stem cell collection might start on day 4th of G-CSF treatment for avoiding G-CSF related side effects and complications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Blood, donors and dollars: Rethinking financial sustainability of safe blood services in Tanzania

    Directory of Open Access Journals (Sweden)

    Kahabi Ganka Isangula

    2016-01-01

    Full Text Available Introduction Collection, processing and distribution of safe blood in Tanzania occurs within a free-for-service context, that is, a collection from non-remunerated blood donors and distributing freely to the needy people through health facilities. The safe blood services in the country appear to be crippled with many challenges and cannot meet the demand for blood and its products. As such, a need for rethinking collection methods, financial models and possible mechanisms for donor remuneration is evident. Methods In this paper, we venture on multi-stakeholder meetings and ongoing discussions regarding the internal mechanisms of safe blood transfusion financing. The intent is to offer a perspective on the considerations for self- sustaining safe blood services in the country and the extent to which they may be implemented or not. Results We suggest that despite huge demand, the external donor dependent financing mechanisms for safe blood services in the country are ineffective. Therefore, we discuss two potential ‘internal’ financing mechanisms that have been identified in recent shareholders forums 1 introducing a blood processing fee accompanied by policy change to allow direct charging of either recipients or hospitals or 2 influencing the introduction of ‘blood services’ within the current insurance schemes. Conclusion We conclude that there is a need for constructing alternative financial mechanisms to sustain the demand of safe blood in the country. We discuss two cost recovery mechanisms, blood processing fee and insurance schemes; however, warning is noted that their implementation warrants structural adjustments, massive community sensitization and optimum stakeholder engagement to maximize acceptability within the country.

  10. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  11. Hepatobiliary system functional analysis by blood flow and clearance delay model

    International Nuclear Information System (INIS)

    Aboltins, A.; Reinholds, E.

    2002-01-01

    A mathematical model for describing liver uptake-excretion is developed and approved. Model is based on different timing delays in hepatobiliary and blood flow system elements. Series of scintigraphic images with 99m Tc-mebrofenins or 99m Tc-HIDA taken with standard nuclear medicine gamma camera are used as the real data for calculations. The time-activity curves are obtained from many regions of human body - heart, liver, gallbladder, spleen, aorta, vein, etc. Both first pass and dynamic acquisition data are used. Results are calculated using real system parameters and compared to real scintigraphy data. Mathematical simulations are made to show difference of hepatobiliary system function at three main points: normal function, good blood flow with bad hepatic function and bad blood flow with good hepatic function. (authors)

  12. Continuous blood pressure recordings simultaneously with functional brain imaging: studies of the glymphatic system

    Science.gov (United States)

    Zienkiewicz, Aleksandra; Huotari, Niko; Raitamaa, Lauri; Raatikainen, Ville; Ferdinando, Hany; Vihriälä, Erkki; Korhonen, Vesa; Myllylä, Teemu; Kiviniemi, Vesa

    2017-03-01

    The lymph system is responsible for cleaning the tissues of metabolic waste products, soluble proteins and other harmful fluids etc. Lymph flow in the body is driven by body movements and muscle contractions. Moreover, it is indirectly dependent on the cardiovascular system, where the heart beat and blood pressure maintain force of pressure in lymphatic channels. Over the last few years, studies revealed that the brain contains the so-called glymphatic system, which is the counterpart of the systemic lymphatic system in the brain. Similarly, the flow in the glymphatic system is assumed to be mostly driven by physiological pulsations such as cardiovascular pulses. Thus, continuous measurement of blood pressure and heart function simultaneously with functional brain imaging is of great interest, particularly in studies of the glymphatic system. We present our MRI compatible optics based sensing system for continuous blood pressure measurement and show our current results on the effects of blood pressure variations on cerebral brain dynamics, with a focus on the glymphatic system. Blood pressure was measured simultaneously with near-infrared spectroscopy (NIRS) combined with an ultrafast functional brain imaging (fMRI) sequence magnetic resonance encephalography (MREG, 3D brain 10 Hz sampling rate).

  13. Time, trust, and transparency: Lessons learned from collecting blood biospecimens for cancer research from the Asian American community.

    Science.gov (United States)

    Dang, Julie H T; Chen, Moon S

    2018-04-01

    Biospecimens from racially diverse groups are needed to advance cancer research. The Asian American Cancer Education Study was developed to increase the number and proportion of blood biospecimen donations from Asian Americans for cancer research. The authors' targeted approach included 2 types of community engagement, in-reach (within institution to Asian American patients with cancer) and outreach (external to institution to the general Asian American community). Participants received in-language biospecimen education followed by the opportunity to donate blood biospecimens. Outreach participants donated through our community biospecimen blood drives, and in-reach participants consented to donating an extra tube of blood during their routine blood draws as a patient. Donated blood biospecimens were spun down to serum and plasma to be stored in a biorepository or were sent to the laboratory to test for cancer-related risk factors. Three hundred eighty-eight Asian Americans donated 1127 blood biospecimens for cancer research. Four hundred twenty tubes of plasma and serum are currently being stored at the cancer center's biorepository, 39 tubes have been used for cancer genomic research, and 668 tubes were used to characterize cancer-related risk factors. Building upon the past decade of the National Cancer Institute-funded Asian American Network for Cancer Awareness, Research, and Training's foundation of trust and service among Asian Americans, researchers were able to leverage relationships not only to introduce the idea of biospecimen contribution to the community but to also exceed expectations with regard to the quantity of blood biospecimens collected from Asian Americans. Cancer 2018;124:1614-21. © 2018 American Cancer Society. © 2018 American Cancer Society.

  14. Development of High Temperature Short Time Vertebrate-Blood Pasteurization Equipment for Tsetse Fly Diets

    Energy Technology Data Exchange (ETDEWEB)

    Moravek, I; Lach, J [Department of Manufacturing Systems, Slovak Technical University Namestie Slobody 17 812 31 Bratislava (Slovakia); Takac, P [Institute of Zoology, SAV, Bratislava (Slovakia)

    2012-07-15

    Tsetse flies feed only on vertebrate blood, but the collection and processing of blood is expensive, it must be stored at -20{sup o}C requiring costly storage rooms and reliable electricity, and it must be irradiated to reduce bacterial contamination. This is tolerable for small colonies, but as colony size increases to service large- scale programmes, the supply and processing of blood becomes critical. Blood is normally collected from cattle at slaughter. This process is necessarily not aseptic, and large-scale collection is only possible where the animals are suspended for bleeding. One alternative to blood decontamination is using the High Temperature Short time Pasteurization (HTST) method. The food processing industry uses pasteurization to reduce bacterial load in a wide range of products. Our previous results indicated that for the control of the blood pasteurization process, to reach satisfactory bacteriological purity and at the same time to prevent the blood from coagulating, it is important to study temperature and time and also some other parameters that could predict blood coagulation. Crucial for blood coagulation is to study blood viscosity. Classical heat exchangers are not suitable for blood pasteurization. In such equipment the blood coagulation depends on temperature and time. Besides the relatively low temperatures, blood is coagulating with cumulative time until total shutdown of blood flow. After a series of experiments we found a solution using microwave systems. To verify the microwave heating concept, we built an experimental workstation. First we verified the accuracy of the applicator design from the aspect of output adaptation to the power source. Also we installed measuring equipment. This system complies with the requirements of quick heating with sufficiently high heat accumulation. By utilizing standard components for the base of the microwave generator, it is possible to markedly reduce the final price of the equipment. (author)

  15. Knowledge and attitudes of pregnant women with regard to collection, testing and banking of cord blood stem cells.

    Science.gov (United States)

    Fernandez, Conrad V; Gordon, Kevin; Van den Hof, Michiel; Taweel, Shaureen; Baylis, Françoise

    2003-03-18

    Umbilical cord blood is used as a source of hematopoietic stem cells for bone marrow transplantation in the treatment of malignant and nonmalignant disease. We sought to examine pregnant women's knowledge and attitudes regarding cord blood banking, as their support is crucial to the success of cord blood transplant programs. A questionnaire examining sociodemographic factors and women's attitudes to cord blood banking was developed on the basis of findings from 2 focus groups and a pilot study. The questionnaire was distributed to 650 women attending antenatal clinics at a regional women's hospital between April and July 2001. A total of 443 women (68%) responded. More than half of the women (307/438 or 70% [95% confidence interval, CI, 66% to 74%]) reported poor or very poor knowledge about cord blood banking. Many of the respondents (299/441 or 68% [95% CI 63% to 72%]) thought that physicians should talk to pregnant women about the collection of cord blood, and they wanted to receive information about this topic from health care professionals (290/441 or 66% [95% CI 61% to 70%]) or prenatal classes (308/441 or 70% [95% CI 65% to 74%]). Most of the women (379/442 or 86% [95% CI 82% to 89%]) would elect to store cord blood in a public bank, many citing altruism as the reason for this choice. A much smaller proportion (63/442 or 14% [95% CI 11% to 18%]) would elect private banking, indicating that this would be a good investment or that they would feel guilty if the blood had not been stored. Additional acceptable uses for cord blood included research (mentioned by 294/436 women or 67% [95% CI 63% to 72%]) and gene therapy (mentioned by 169/437 women or 39% [95% CI 34% to 43%]). Most of the women in this study supported the donation of cord blood to public cord blood banks for potential transplantation and research.

  16. Volunteer-based distributed traffic data collection system

    DEFF Research Database (Denmark)

    Balachandran, Katheepan; Broberg, Jacob Honoré; Revsbech, Kasper

    2010-01-01

    An architecture for a traffic data collection system is proposed, which can collect data without having access to a backbone network. Contrary to other monitoring systems it relies on volunteers to install a program on their own computers, which will capture incoming and outgoing packets, group t...... case performance estimates indicate that this is obtained. Tests conducted by volunteers using an implemented prototype confirm the feasibility of the system......An architecture for a traffic data collection system is proposed, which can collect data without having access to a backbone network. Contrary to other monitoring systems it relies on volunteers to install a program on their own computers, which will capture incoming and outgoing packets, group...... them into flows and send the flow data to a central server. Data can be used for studying and characterising internet traffic and for testing traffic models by regenerating real traffic. The architecture is designed to have efficient and light usage of resources on both client and server sides. Worst...

  17. Accuracy and precision evaluation of seven self-monitoring blood glucose systems.

    Science.gov (United States)

    Kuo, Chih-Yi; Hsu, Cheng-Teng; Ho, Cheng-Shiao; Su, Ting-En; Wu, Ming-Hsun; Wang, Chau-Jong

    2011-05-01

    Self-monitoring blood glucose (SMBG) systems play a critical role in management of diabetes. SMBG systems should at least meet the minimal requirement of the World Health Organization's ISO 15197:2003. For tight glycemic control, a tighter accuracy requirement is needed. Seven SMBG systems were evaluated for accuracy and precision: Bionime Rightest(™) GM550 (Bionime Corp., Dali City, Taiwan), Accu-Chek(®) Performa (Roche Diagnostics, Indianapolis, IN), OneTouch(®) Ultra(®)2 (LifeScan Inc., Milpitas, CA), MediSense(®) Optium(™) Xceed (Abbott Diabetes Care Inc., Alameda, CA), Medisafe (TERUMO Corp., Tokyo, Japan), Fora(®) TD4227 (Taidac Technology Corp., Wugu Township, Taiwan), and Ascensia Contour(®) (Bayer HealthCare LLC, Mishawaka, IN). The 107 participants (44 men and 63 women) were between 23 and 91 years old. The analytical results of seven SMBG systems were compared with those of plasma analyzed with the hexokinase method (Olympus AU640, Olympus America Inc., Center Valley, PA). The imprecision of the seven blood glucose meters ranged from 1.1% to 4.7%. Three of the seven blood glucose meters (42.9%) fulfilled the minimum accuracy criteria of ISO 15197:2003. The mean absolute relative error value for each blood glucose meter was calculated and ranged from 6.5% to 12.0%. More than 40% of evaluated SMBG systems meet the minimal accuracy criteria requirement of ISO 15197:2003. However, considering tighter criteria for accuracy of ±15%, only the Bionime Rightest GM550 meets this requirement. Because SMBG systems play a critical role in management of diabetes, manufacturers have to strive to improve accuracy and precision and to ensure the good quality of blood glucose meters and test strips.

  18. Environmental-benefit analysis of two urban waste collection systems.

    Science.gov (United States)

    Aranda Usón, Alfonso; Ferreira, Germán; Zambrana Vásquez, David; Zabalza Bribián, Ignacio; Llera Sastresa, Eva

    2013-10-01

    Sustainable transportation infrastructure and travel policies aim to optimise the use of transportation systems to achieve economic and related social and environmental goals. To this end, a novel methodology based on life cycle assessment (LCA) has been developed in this study, with the aim of quantifying, in terms of CO2 emissions equivalent, the impact associated with different alternatives of waste collection systems in different urban typologies. This new approach is focussed on saving energy and raw materials and reducing the environmental impact associated with the waste collection system in urban areas, as well as allowing the design and planning of the best available technologies and most environment-friendly management. The methodology considers a large variety of variables from the point of view of sustainable urban transport such as the location and size of the urban area, the amount of solid waste generated, the level of social awareness on waste separation procedures, the distance between houses and waste collection points and the distance from the latter to the possible recovery plants and/or landfills, taking into account the material and energy recovery ratio within an integrated waste management system. As a case study, two different waste collection systems have been evaluated with this methodology in the ecocity Valdespartera located in Zaragoza, Spain, consisting of approximately 10,000 homes: (i) a system based on traditional truck transportation and manual collection, and (ii) a stationary vacuum waste collection system. Results show that, when operating at loads close to 100%, the stationary collection system has the best environmental performance in comparison with the conventional system. In contrast, when operating at load factors around 13% the environmental benefits in terms of net CO2-eq. emissions for the stationary collection system are around 60% lower in comparison with the conventional one. Copyright © 2013 Elsevier B.V. All

  19. Cord Blood

    Directory of Open Access Journals (Sweden)

    Saeed Abroun

    2014-05-01

    Full Text Available   Stem cells are naïve or master cells. This means they can transform into special 200 cell types as needed by body, and each of these cells has just one function. Stem cells are found in many parts of the human body, although some sources have richer concentrations than others. Some excellent sources of stem cells, such as bone marrow, peripheral blood, cord blood, other tissue stem cells and human embryos, which last one are controversial and their use can be illegal in some countries. Cord blood is a sample of blood taken from a newborn baby's umbilical cord. It is a rich source of stem cells, umbilical cord blood and tissue are collected from material that normally has no use following a child’s birth. Umbilical cord blood and tissue cells are rich sources of stem cells, which have been used in the treatment of over 80 diseases including leukemia, lymphoma and anemia as bone marrow stem cell potency.  The most common disease category has been leukemia. The next largest group is inherited diseases. Patients with lymphoma, myelodysplasia and severe aplastic anemia have also been successfully transplanted with cord blood. Cord blood is obtained by syringing out the placenta through the umbilical cord at the time of childbirth, after the cord has been detached from the newborn. Collecting stem cells from umbilical blood and tissue is ethical, pain-free, safe and simple. When they are needed to treat your child later in life, there will be no rejection or incompatibility issues, as the procedure will be using their own cells. In contrast, stem cells from donors do have these potential problems. By consider about cord blood potency, cord blood banks (familial or public were established. In IRAN, four cord blood banks has activity, Shariati BMT center cord blood bank, Royan familial cord blood banks, Royan public cord blood banks and Iranian Blood Transfusion Organ cord blood banks. Despite 50,000 sample which storage in these banks, but the

  20. Project W-049H Collection System Acceptance Test

    International Nuclear Information System (INIS)

    Buckles, D.I.

    1994-01-01

    The Acceptance Test Procedure (ATP) Program for Project W-049H covers the following activities: Disposal system, Collection system, Instrumentation and control system. Each activity has its own ATP. The purpose of the ATPs is to verify that the systems have been constructed in accordance with the construction documents and to demonstrate that the systems function as required by the Project criteria. This ATP has been prepared to demonstrate that the Collection System Instrumentation functions as required by project criteria

  1. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  2. NLO error propagation exercise data collection system

    International Nuclear Information System (INIS)

    Keisch, B.; Bieber, A.M. Jr.

    1983-01-01

    A combined automated and manual system for data collection is described. The system is suitable for collecting, storing, and retrieving data related to nuclear material control at a bulk processing facility. The system, which was applied to the NLO operated Feed Materials Production Center, was successfully demonstrated for a selected portion of the facility. The instrumentation consisted of off-the-shelf commercial equipment and provided timeliness, convenience, and efficiency in providing information for generating a material balance and performing error propagation on a sound statistical basis

  3. Modelling of the Blood Coagulation Cascade in an In Vitro Flow System

    DEFF Research Database (Denmark)

    Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.

    2010-01-01

    We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade....

  4. Platelet concentrates stored in plasma for 72 hours at 22 degrees C prepared from buffycoats of citrate-phosphate-dextrose blood collected in a quadruple-bag saline-adenine-glucose-mannitol system

    NARCIS (Netherlands)

    Pietersz, R. N.; Loos, J. A.; Reesink, H. W.

    1985-01-01

    A method is described to prepare platelet concentrates from the buffycoat of citrate-phosphate-dextrose (CPD) blood in a closed four-bag system and to store the platelets in autologous plasma under sterile conditions. After separation of the blood into plasma, buffycoat and leukocyte- and

  5. Blood meal analysis and virus detection in blood-fed mosquitoes collected during the 2006-2007 Rift Valley fever outbreak in Kenya.

    Science.gov (United States)

    Lutomiah, Joel; Omondi, David; Masiga, Daniel; Mutai, Collins; Mireji, Paul O; Ongus, Juliette; Linthicum, Ken J; Sang, Rosemary

    2014-09-01

    Rift Valley fever (RVF) is a zoonosis of domestic ruminants in Africa. Blood-fed mosquitoes collected during the 2006-2007 RVF outbreak in Kenya were analyzed to determine the virus infection status and animal source of the blood meals. Blood meals from individual mosquito abdomens were screened for viruses using Vero cells and RT-PCR. DNA was also extracted and the cytochrome c oxidase 1 (CO1) and cytochrome b (cytb) genes amplified by PCR. Purified amplicons were sequenced and queried in GenBank and Barcode of Life Database (BOLD) to identify the putative blood meal sources. The predominant species in Garissa were Aedes ochraceus, (n=561, 76%) and Ae. mcintoshi, (n=176, 24%), and Mansonia uniformis, (n=24, 72.7%) in Baringo. Ae. ochraceus fed on goats (37.6%), cattle (16.4%), donkeys (10.7%), sheep (5.9%), and humans (5.3%). Ae. mcintoshi fed on the same animals in almost equal proportions. RVFV was isolated from Ae. ochraceus that had fed on sheep (4), goats (3), human (1), cattle (1), and unidentified host (1), with infection and dissemination rates of 1.8% (10/561) and 50% (5/10), respectively, and 0.56% (1/176) and 100% (1/1) in Ae. mcintoshi. In Baringo, Ma. uniformis fed on sheep (38%), frogs (13%), duikers (8%), cattle (4%), goats (4%), and unidentified hosts (29%), with infection and dissemination rates of 25% (6/24) and 83.3% (5/6), respectively. Ndumu virus (NDUV) was also isolated from Ae. ochraceus with infection and dissemination rates of 2.3% (13/561) and 76.9% (10/13), and Ae. mcintoshi, 2.8% (5/176) and 80% (4/5), respectively. Ten of the infected Ae. ochraceus had fed on goats, sheep (1), and unidentified hosts (2), and Ae. mcintoshi on goats (3), camel (1), and donkey (1). This study has demonstrated that RVFV and NDUV were concurrently circulating during the outbreak, and sheep and goats were the main amplifiers of these viruses respectively.

  6. Collective Motion in Behaviorally Heterogeneous Systems

    Science.gov (United States)

    Copenhagen, Katherine

    Collective motion is a widespread phenomenon in nature where individuals actively propel themselves, gather together and move as a group. Some examples of collective motion are bird flocks, fish schools, bacteria swarms, cell clusters, and crowds of people. Many models seek to understand the effects of activity in collective systems including things such as environmental disorder, density, and interaction details primarily at infinite size limits and with uniform populations. In this dissertation I investigate the effects of finite sizes and behavioral heterogeneity as it exists in nature. Behavioral heterogeneity can originate from several different sources. Mixed populations of individuals can have inherently different behaviors such as mutant bacteria, injured fish, or agents that prefer individualistic behavior over coordinated motion. Alternatively, agents may modify their own behavior based on some local environmental dependency, such as local substrate, or density. In cases such as mutant cheaters in bacteria or malfunctioning drones in swarms, mixed populations of behaviorally heterogeneous agents can be modelled as arising in the form of aligning and non-aligning agents. When this kind of heterogeneity is introduced, there is a critical carrying capacity of non-aligners above which the system is unable to form a cohesive ordered group. However, if the cohesion of the group is relaxed to allow for fracture, the system will actively sort out non-aligning agents the system will exist at a critical non-aligner fraction. A similar heterogeneity could result in a mixture of high and low noise individuals. In this case there is also a critical carry capacity beyond which the system is unable to reach an ordered state, however the nature of this transition depends on the model details. Agents which are part of an ordered collective may vary their behavior as the group changes environments such as a flock of birds flying into a cloud. Using a unique model of a

  7. Online information system for data collection of cattle quality

    Science.gov (United States)

    Sugiharti, E.; Arifudin, R.; Putra, A. T.

    2018-03-01

    Innovation and development of the science and technology which proclaimed by the government through Ristekdikti need to be supported. On the other hand, the Department of Animal Husbandry and Fisheries began introducing the Cattle Card system that contains the identity of each farm animal. Therefore, UNNES especially the Department of Computer Science of FMIPA UNNES, need to give positive contribution in the field of Science and Technology to support the manual system of Cattle Card, through the preparation of prototype of the online information system of data collection of cattle in Semarang regency. The main problem is how to monitor the data of cattle quality through online information system in Semarang regency? The purpose of this research is to produce the prototype of an online information system for data collection of cattle quality in Semarang regency. Main activities: (1) Prepare the flowchart of an online system for data collection of cattle quality. (2) Collecting data to obtain data on identity descriptions of each cattle, owners, mutation records, and health records of livestock cattle. (3) Creation of the prototype of an online information system for data collection of cattle quality in Semarang Regency. The results, (1) had been produced the prototype of an online information system for data collection of cattle in the region of Semarang regency. (2) Socialization of the online information system for cattle quality data collection and exploring input from various related stakeholders. (3) There had been a limited trial of prototypes of the system in Pabelan district in the working area of the Department of Animal Husbandry and Fisheries of Semarang regency and succeeded well.

  8. A measure of internal synergy of the collective system

    Directory of Open Access Journals (Sweden)

    Novikov V.A.

    2013-12-01

    Full Text Available Background: The authors examine the methodology of HRM personnel management based on ratings. Proposed to represent a collective system that uses a matrix of pair relations as a system of linear differential equations. The condition of auto generation of an autonomous system can be determined by the application of the Laplace transformation to the system. This condition mainly depends on the main eigenvalue of dating relationships matrix. Assuming the oscillation frequency is straightly proportional to the system's synergy rating, a special algorithm of comparative evaluation of several collective systems was suggested. Methods: The calculation of the rating of internal synergies is based on the representation of the collective system as a system of linear differential equations, the coefficients of which are obtained by questionnaire survey of all members of the team. Internal representation of the system's synergism as a stimulation of an autonomous system allows using the eigenvector of the system as a measure of internal synergies. Results: The result of this method is the rating of members of interacting collective systems in terms of their contribution to the self-organization sharing behavior.  Conclusions:  Using a matrix of pair relations allows without direct programming and only using MathCad determines the measure of internal synergy of a collective system.  

  9. Radiation-induced micronucleus frequencies in female peripheral blood lymphocytes collected during the first and second half of the menstrual cycle

    International Nuclear Information System (INIS)

    Krol, M.; Lankoff, A.; Buraczewska, I.; Derezinska, E.; Wojcik, A.

    2007-01-01

    Biological dosimetry relies on the assessment of dose in peripheral blood lymphocytes (PBL) of a victim. Variability in the individual radiosensitivity of PBL has an impact on the precision of dose estimate and radiation-induced micronuclei show a strong individual variability. A factor which can influence the radiosensitivity of PBL is the hormonal status of female donors, which shows a regular pattern during the menstrual cycle. The aim of the present investigation was to verify whether the position within the menstrual cycle has an impact on the level of micronuclei in PBL. Blood was collected from 19 donors during the first and second half of the menstrual cycle and exposed to 2 Gy. Although statistically significant differences between the MN frequencies in PBL collected during the different time points were observed in the case of some donors, no reproducible trend that could find application in biological dosimetry could be detected. (authors)

  10. Rational Clinical Use of Blood and Blood products – A summary

    Directory of Open Access Journals (Sweden)

    D Ghartimagar

    2017-03-01

    Full Text Available Blood transfusion is an essential therapeutic intervention. The main role of the blood centre is to provide safe and timely blood and blood component(s to the patients that will improve the physiological status of the patient. Various blood components can be harvested from a single donation of whole blood. The blood centre ensures that there is an adequate inventory of all blood types and blood components to meet the needs of the patients. The blood centre does donor selection, blood collection, component preparation, screening for transfusion – transmitted infections and blood processing. Serologically compatible blood and components are provided to the patients after meticulous pre-transfusion testing as per the standard protocol. Rational use of blood and blood products means right product is used with the right dose on right time for the right reason.

  11. Immunomodulating effect of blood transfusion: is storage time important?

    DEFF Research Database (Denmark)

    Mynster, T; Dybkjoer, E; Kronborg, Gitte

    1998-01-01

    in stimulating TNF-alpha and IL-2 release in an ex vivo assay. METHODS: Supernatants of 10 units of whole blood and 10 units of SAGM blood were collected after 1, 21 and 35 days of standard blood bank storage. Heparinized blood from 20 healthy volunteers (as 'recipients'), corresponding in ABO and Rh type......OBJECTIVES: TNF-alpha and IL-2 are important cytokines in macrophage and T-lymphocyte activity against infection and dissemination of malignant cells. We studied the influence of supernatants from stored whole blood and buffy-coat-depleted SAGM (saline, adenine, glucose and mannitol) blood...... to the stored blood, were used in a culture system with LPS and PHA as stimulators of TNF-alpha and IL-2 release. The effect of added supernatants, from either stored whole blood or SAGM blood, on cytokine release was evaluated compared to saline as control. TNF-alpha concentration was analyzed by ELISA after...

  12. Using improved technology for filter paper-based blood collection to survey wild Sika deer for antibodies to hepatitis E virus

    OpenAIRE

    Yu, Claro; Zimmerman, Carl; Stone, Roger; Engle, Ronald E.; Elkins, William; Nardone, Glenn A.; Emerson, Suzanne U.; Purcell, Robert H.

    2007-01-01

    Recent reports from Japan implicated wild Sika deer (Cervus nippon) in the zoonotic transmission of hepatitis E to humans. Seroprevalence studies were performed to determine if imported feral populations of Sika deer in Maryland and Virginia posed a similar risk of transmitting hepatitis E virus (HEV). Hunters collected blood on filter paper disks from freshly killed deer. The disks were desiccated and delivered to a collection point. The dried filters were weighed to estimate the amount of b...

  13. Evaluation of OneTouch Verio(®), a new blood glucose self-monitoring system for patients with diabetes

    DEFF Research Database (Denmark)

    Littmann, Karin; Petersen, Eva; Pussinen, Christel

    2013-01-01

    tested by laboratory personnel and within the goal of imprecision suggested by ADA. Mean CV% of repeatability for patient self-monitoring was 5.0% and 5.1% in the training- and the mail group, respectively. Total error was 6.4-10.0%. The OneTouch Verio(®) showed no hematocrit interference or variation...... Association (ADA) quality goals. Blood samples were collected and measured on the OneTouch Verio(®) by laboratory personnel and patients with diabetes (n = 91, randomized into groups receiving personal training or mail instructions for the OneTouch Verio(®) system). Results were compared to a validated...... between strip lots. Conclusion. The OneTouch Verio(®) displayed sufficient analytical quality and satisfactory user-friendliness. It is suitable for point-of-care testing of blood glucose concentration when handled by patients and healthcare professionals....

  14. SYSTEMIC COMPLICATIONS AND THEIR RISK FACTORS AMONG TEHRANIAN BLOOD DONOR, 2005

    OpenAIRE

    F. Majlessi; S. Ghafari; A. Rahimi-Foroushani M. Maghsoodlou

    2008-01-01

    The systemic complications of blood donation are the first reasons why patients fail to return for further blood donation. This study was designed to determine the frequency of these complications and their associated risk factors among blood donors in Tehran. Also, we aimed to provide suitable methods to decrease the frequency of these adverse events, thereby eliminating the most important causes of withdrawal, while maintaining the health of the donors. This analytical descriptive cross-sec...

  15. Identification of hybrids of painted and milky storks using FTA card-collected blood, molecular markers, and morphologies.

    Science.gov (United States)

    Yee, Elsie Yoke Sim; Zainuddin, Zainal Zahari; Ismail, Ahmad; Yap, Chee Kong; Tan, Soon Guan

    2013-10-01

    Suspicious hybrids of painted storks and milky storks were found in a Malaysian zoo. Blood of these birds was sampled on FTA cards for DNA fingerprinting. Of 44 optimized primers, 6 produced diagnostic markers that could identify hybrids. The markers were based on simple, direct PCR-generated multilocus banding patterns that provided two sets of genetic data, one for each of the two stork species and another for the hybrids. It also revealed that large DNA fragments (3,000 bp) could be amplified from blood collected on FTA cards. When the results of each individual bird's DNA fingerprint were compared with plumage characters, the hybrids were found to express a range of intermediate phenotypic traits of the pure breeds with no dominant plumage characteristic from either parental species.

  16. Influence of Partial Pressure of Oxygen in Blood Samples on Measurement Performance in Glucose-Oxidase-Based Systems for Self-Monitoring of Blood Glucose

    Science.gov (United States)

    Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Haug, Cornelia; Freckmann, Guido

    2013-01-01

    Background Partial pressure of oxygen (pO2) in blood samples can affect blood glucose (BG) measurements, particularly in systems that employ the glucose oxidase (GOx) enzyme reaction on test strips. In this study, we assessed the impact of different pO2 values on the performance of five GOx systems and one glucose dehydrogenase (GDH) system. Two of the GOx systems are labeled by the manufacturers to be sensitive to increased blood oxygen content, while the other three GOx systems are not. Methods Aliquots of 20 venous samples were adjusted to the following pO2 values: pO2 ~70 mmHg, which is considered to be similar to pO2 in capillary blood samples, and the mean BG result at pO2 pO2 pO2 ≥150 mmHg. For both pO2 levels, relative differences of all tested GOx systems were significant (p pO2 values pO2 variations lead to clinically relevant BG measurement deviations in GOx systems, even in GOx systems that are not labeled as being oxygen sensitive. PMID:24351177

  17. Positive Reinforcement Training for Blood Collection in Grizzly Bears (Ursus arctos horribilis) Results in Undetectable Elevations in Serum Cortisol Levels: A Preliminary Investigation.

    Science.gov (United States)

    Joyce-Zuniga, Nicole M; Newberry, Ruth C; Robbins, Charles T; Ware, Jasmine V; Jansen, Heiko T; Nelson, O Lynne

    2016-01-01

    Training nonhuman animals in captivity for participation in routine husbandry procedures is believed to produce a lower stress environment compared with undergoing a general anesthetic event for the same procedure. This hypothesis rests largely on anecdotal evidence that the captive subjects appear more relaxed with the trained event. Blood markers of physiological stress responses were evaluated in 4 captive grizzly bears (Ursus arctos horribilis) who were clicker-trained for blood collection versus 4 bears who were chemically immobilized for blood collection. Serum cortisol and immunoglobulin A (IgA) and plasma β-endorphin were measured as indicators of responses to stress. Plasma β-endorphin was not different between the groups. Serum IgA was undetectable in all bears. Serum cortisol was undetectable in all trained bears, whereas chemically immobilized bears had marked cortisol elevations (p bears with extensive recent immobilization experience. These findings support the use of positive reinforcement training for routine health procedures to minimize anxiety.

  18. Cold Vacuum Drying facility sanitary sewage collection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) sanitary sewage collection system. The sanitary sewage collection system provides collection and storage of effluents and raw sewage from the CVDF to support the cold vacuum drying process. This system is comprised of a sanitary sewage holding tank and pipes for collection and transport of effluents to the sanitary sewage holding tank

  19. Collection of master-slave synchronized chaotic systems

    International Nuclear Information System (INIS)

    Lerescu, A.I.; Constandache, N.; Oancea, S.; Grosu, I.

    2004-01-01

    In this work the open-plus-closed-loop (OPCL) method of synchronization is used in order to synchronize the systems from the Sprott's collection of the simplest chaotic systems. The method is general and we looked for the simplest coupling between master and slave. The main result is that for the systems that contains one nonlinear term and that term contains one variable then the coupling consists of one term. The numerical intervals of parameters where the synchronization is achieved are obtained analytically by applying Routh-Hurwitz conditions. Detailed calculations and numerical results are given for the system I from the Sprott's collection. Working in the same manner for many systems this method can be adopted for the teaching of the topic

  20. Liver-inherent immune system: its role in blood-stage malaria.

    Science.gov (United States)

    Wunderlich, Frank; Al-Quraishy, Saleh; Dkhil, Mohamed A

    2014-01-01

    The liver is well known as that organ which is obligately required for the intrahepatocyte development of the pre-erythrocytic stages of the malaria-causative agent Plasmodium. However, largely neglected is the fact that the liver is also a central player of the host defense against the morbidity- and mortality-causing blood stages of the malaria parasites. Indeed, the liver is equipped with a unique immune system that acts locally, however, with systemic impact. Its main "antipodal" functions are to recognize and to generate effective immunoreactivity against pathogens on the one hand, and to generate tolerance to avoid immunoreactivity with "self" and harmless substances as dietary compounds on the other hand. This review provides an introductory survey of the liver-inherent immune system: its pathogen recognition receptors including Toll-like receptors (TLRs) and its major cell constituents with their different facilities to fight and eliminate pathogens. Then, evidence is presented that the liver is also an essential organ to overcome blood-stage malaria. Finally, we discuss effector responses of the liver-inherent immune system directed against blood-stage malaria: activation of TLRs, acute phase response, phagocytic activity, cytokine-mediated pro- and anti-inflammatory responses, generation of "protective" autoimmunity by extrathymic T cells and B-1 cells, and T cell-mediated repair of liver injuries mainly produced by malaria-induced overreactions of the liver-inherent immune system.

  1. Update on the use of blood and blood products in ruminants.

    Science.gov (United States)

    Balcomb, Christie; Foster, Derek

    2014-07-01

    The use of whole blood and/or blood products is indicated in ruminant medicine. The goal of this article is to summarize previous literature on blood groups in ruminants and camelids, list indications for transfusion, and describe collection and transfusion techniques applicable to small ruminants and cattle that can be used in practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Collection and composition of autologous peripheral blood stem cells graft in patients with acute myeloid leukemia: influence on hematopoietic recovery and outcome.

    Science.gov (United States)

    Raos, Mirela; Nemet, Damir; Bojanić, Ines; Sertić, Dubravka; Batinić, Drago; Dusak, Vesna; Dubravcić, Klara; Mazić, Sanja; Serventi-Seiwerth, Ranka; Mrsić, Mirando; Golubić-Cepulić, Branka; Labar, Boris

    2010-03-01

    Hematopoietic stem cell (HSC) transplantation is a standard approach in the treatment of hematological malignant diseases. For the last 15 years the main source of cells for transplantation have been peripheral blood stem cells (PBSC). With the availability of hematopoietic growth factors and understanding the advantages of treatment with PBSC, the application of bone marrow (BM) was supplanted. The aim of this survey was to explore the success of PBSC collection, the factors which influence the success of PBSC collection, the composition and the quality of graft and their influence on hematopoietic recovery and outcome after transplantation in patients with acute myeloid leukemia (AML). PBSC were collected by the method of leukapheresis after applying a combination of chemotherapy and growth factors or only growth factors. The quality of graft was determined with the clonogenic progenitor cell assay and with the flow cytometry analysis. Of the total 134 patients with AML, who were submitted to HSC mobilization, the collection was successful in 78 (58.2%) patients. The collection was more successful after the first than after the second attempt of HSC mobilization (49% vs. 11%). The criteria for effective mobilization were the number of leukocytes > 3 x 10(9)/L and the concentration of CD34+ cells > 20 x 10(3)/mL in the peripheral blood on the first day of leukapheresis. The number of CD34+ cells infused had the strongest impact on hematopoietic recovery. We noted significantly faster hematological recovery of neutrophils and platelets, fewer number of transfused units of red blood cells and platelets, shorter duration of the tranfusion support, shorter treatment with intravenous antibiotic therapy and shorter hospitalization after PBSC compared to BM transplantation. These advantages could provide their standard application in the treatment of patients with AML.

  3. A geological and geophysical data collection system

    Digital Repository Service at National Institute of Oceanography (India)

    Sudhakar, T.; Afzulpurkar, S.

    A geological and geophysical data collection system using a Personal Computer is described below. The system stores data obtained from various survey systems typically installed in a charter vessel and can be used for similar applications on any...

  4. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring

    OpenAIRE

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-01-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery–powered electrochemical twin channels (ETCs). The ...

  5. Comparison of the Fenwal Amicus and Fresenius Com.Tec cell separators for autologous peripheral blood progenitor cell collection.

    Science.gov (United States)

    Altuntas, Fevzi; Kocyigit, Ismail; Ozturk, Ahmet; Kaynar, Leylagul; Sari, Ismail; Oztekin, Mehmet; Solmaz, Musa; Eser, Bulent; Cetin, Mustafa; Unal, Ali

    2007-04-01

    Peripheral blood progenitor cells (PBPC) are commonly used as a stem cell source for autologous transplantation. This study was undertaken to evaluate blood cell separators with respect to separation results and content of the harvest. Forty autologous PBPC collections in patients with hematological malignancies were performed with either the Amicus or the COM.TEC cell separators. The median product volume was lower with the Amicus compared to the COM.TEC (125 mL vs. 300 mL; p < 0.001). There was no statistically significant difference in the median number of CD34+ cell/kg in product between the Amicus and the COM.TEC (3.0 x 10(6) vs. 4.1 x 10(6); p = 0.129). There was a statistically higher mean volume of ACD used in collections on the Amicus compared to the COM.TEC (1040 +/- 241 mL vs. 868 +/- 176 mL; p = 0.019). There was a statistical difference in platelet (PLT) contamination of the products between the Amicus and the COM.TEC (0.3 x 10(11) vs. 1.1 x 10(11); p < 0.001). The median % decrease in PB PLT count was statistically higher in the COM.TEC compared to the Amicus instruments (18.5% vs. 9.5%; p = 0.028). In conclusion, both instruments collected PBPCs efficiently. However, Amicus has the advantage of lower PLT contamination in the product, and less decrease in PB platelet count with lower product volume in autologous setting.

  6. Evaluating the optimum rest period prior to blood collection for fractionated plasma free metanephrines analysis

    LENUS (Irish Health Repository)

    Griffin, T.P.

    2016-05-01

    The high diagnostic accuracy of plasma metanephrines (PMets) in the di-agnosis of Phaeochromocytoma\\/Paraganglioma (PPGL) is well established. Considerable controversy exists regarding optimum sampling conditions for PMets. The use of reference intervals that do not compromise diagnostic sensitivity is recommended. However, the optimum rest period prior to sampling has yet to be clearly established. The aim of this study was to evaluate PMets concentrations in paired blood samples collected following 30 and 40 min seated-rest prior to sampling, in patients in whom it was clinically rea-sonable to suspect that PPGL may be present.

  7. Redesigning a collection system for 'small' consumer electronics

    International Nuclear Information System (INIS)

    Melissen, Frans W.

    2006-01-01

    This paper establishes that the collection system within the recycling scheme for consumer electronics in the Netherlands has not been entirely successful in convincing consumers to hand in their used appliances by means of dedicated collection routes. Particularly regarding small appliances, consumers are persisting in their habit of discarding their appliances by means of the refuse bag/bin for regular household waste. Therefore, the current collection system has been unable to direct consumer behavior in the desired direction. Consequently, the layout of the current system is reviewed and redesigned in order to tackle this problem. This design effort applies the Triad model (behavioral model) in the analysis stage and the Morphological Chart method (design tool) in the synthesis stage, and results in a concrete proposal for a new system. Finally, the applicability of this design approach beyond the specific circumstances of the case study presented in this paper is discussed. This case represents only one example of the broader, worldwide challenge to design appropriate collection systems to direct consumer behavior in desired directions. It is argued that the approach presented in this paper could be a valuable contribution to research dealing with this challenge

  8. A portable system for processing donated whole blood into high quality components without centrifugation.

    Science.gov (United States)

    Gifford, Sean C; Strachan, Briony C; Xia, Hui; Vörös, Eszter; Torabian, Kian; Tomasino, Taylor A; Griffin, Gary D; Lichtiger, Benjamin; Aung, Fleur M; Shevkoplyas, Sergey S

    2018-01-01

    The use of centrifugation-based approaches for processing donated blood into components is routine in the industrialized world, as disparate storage conditions require the rapid separation of 'whole blood' into distinct red blood cell (RBC), platelet, and plasma products. However, the logistical complications and potential cellular damage associated with centrifugation/apheresis manufacturing of blood products are well documented. The objective of this study was to evaluate a proof-of-concept system for whole blood processing, which does not employ electromechanical parts, is easily portable, and can be operated immediately after donation with minimal human labor. In a split-unit study (n = 6), full (~500mL) units of freshly-donated whole blood were divided, with one half processed by conventional centrifugation techniques and the other with the new blood separation system. Each of these processes took 2-3 hours to complete and were performed in parallel. Blood products generated by the two approaches were compared using an extensive panel of cellular and plasma quality metrics. Comparison of nearly all RBC parameters showed no significant differences between the two approaches, although the portable system generated RBC units with a slight but statistically significant improvement in 2,3-diphosphoglyceric acid concentration (p applications in remote or resource-limited settings, or for patients requiring highly functional platelet product.

  9. A data-driven approach to patient blood management.

    Science.gov (United States)

    Cohn, Claudia S; Welbig, Julie; Bowman, Robert; Kammann, Susan; Frey, Katherine; Zantek, Nicole

    2014-02-01

    Patient blood management (PBM) has become a topic of intense interest; however, implementing a robust PBM system in a large academic hospital can be a challenge. In a joint effort between transfusion medicine and information technology, we have developed three overlapping databases that allow for a comprehensive, semiautomated approach to monitoring up-to-date red blood cell (RBC) usage in our hospital. Data derived from this work have allowed us to target our PBM efforts. Information on transfusions is collected using three databases: daily report, discharge database, and denominator database. The daily report collects data on all transfusions in the past 24 hours. The discharge database integrates transfusion data and diagnostic billing codes. The denominator database allows for rate calculations by tracking all patients with a hemoglobin test ordered. A set of algorithms is applied to automatically audit RBC transfusions. The transfusions that do not fit the algorithms' rules are manually reviewed. Data from audits are compiled into reports and distributed to medical directors. Data are also used to target education efforts. Since our PBM program began, the percentage of appropriate RBC orders increased from an initial 70%-80% to 90%-95%, and the overall RBC transfusions/1000 patient-days has decreased by 67% in targeted areas of the hospital. Our PBM program has shaved approximately 3% from our hospital's blood budget. Our semiautomated auditing system allows us to quickly and comprehensively analyze and track blood usage throughout our hospital. Using this technology, we have seen improvements in our hospital's PBM. © 2013 American Association of Blood Banks.

  10. Prevalence of antibodies to a new histo-blood system: the FORS system.

    Science.gov (United States)

    Jesus, Carlos; Hesse, Camilla; Rocha, Clara; Osório, Nádia; Valado, Ana; Caseiro, Armando; Gabriel, António; Svensson, Lola; Moslemi, Ali-Reza; Siba, Wafa Abu; Srour, Mahmoud A; Pereira, Cristina; Tomaz, Jorge; Teixeira, Paulo; Mendes, Fernando

    2018-02-01

    In 1987, three unrelated English families were reported with a putative blood subgroup called A pae . Swedish researchers later found evidence leading to abolishment of the A pae subgroup and establishment instead of the FORS blood group system (System 31 - ISBT, 2012). It is important to know the prevalence of antibodies in order to make the best decisions in transfusion medicine. Cells expressing the Forssman saccharide, such as sheep erythrocytes, are needed to detect the anti-Forssman antibody. The aim of this study was to define the prevalence of human anti-Forssman antibody. Plasma samples from 800 individuals were studied. Sheep erythrocytes or Forssman "kodecytes" were mixed with the plasma samples using the tube technique. Plasma from an A pae individual was used as a negative control and monoclonal anti-Forssman antibody (M1/22.25.8HL cell line supernatant) was used as the positive control. Of the 800 individuals tested, one was negative for the presence of anti-Forssman antibody. We compared the anti-Forssman antibody reaction pattern between genders and found that males have weaker reactions than females, both at room temperature (p=0.026) and at 37 °C (p=0.043). We also investigated the reaction pattern of anti-Forssman antibody in relation to ABO and Rh blood group types without finding any significant differences. Sheep erythrocytes are suitable for searching for human anti-Forssman antibody. The quantity of anti-Forssman antibodies in plasma is higher in females than in males. In the population (n=800) studied here, we found one individual lacking the anti-Forssman antibody. These results contribute to the data already published, confirming that FORS is a rare blood group.

  11. Mycobacterium tuberculosis bacteremia detected by the Isolator lysis-centrifugation blood culture system.

    OpenAIRE

    Kiehn, T E; Gold, J W; Brannon, P; Timberger, R J; Armstrong, D

    1985-01-01

    Mycobacterium tuberculosis was detected by the Isolator lysis-centrifugation blood culture system from the blood of a patient with tuberculosis of the breast. The organism also grew on conventional laboratory media inoculated with pleural fluid from the patient.

  12. Seasonal blood shortages can be eliminated.

    Science.gov (United States)

    Gilcher, Ronald O; McCombs, Suzanne

    2005-11-01

    This review is designed to help readers understand seasonal blood shortages and provide solutions through the use of technology that can increase the number of red blood cell units collected and the use of recruitment and marketing initiatives that appeal to the increasingly diverse donor base. Seasonal shortages are, in reality, mostly shortages of group O red blood cells and occur most commonly during midsummer and early winter. The shortages occur primarily from increased use of group O red blood cells at times of decreased donor availability. While reducing the disproportionate use of red cells will help, blood centers can more quickly reduce the seasonal deficits by using automated red cell technology to collect double red blood cell units; targeted marketing programs to provide effective messages; seasonal advertising campaigns; and recognition, benefits, and incentives to enhance the donor motivation donation threshold. A multi-level approach to increasing blood donations at difficult times of the year can ensure that donations are increased at a time when regular donor availability is decreased. Seasonal blood shortages can be eliminated by understanding the nature of the shortages, why and when they occur, and using more sophisticated recruitment and marketing strategies as well as automated collection technologies to enhance the blood supply.

  13. Blood biochemistry and immune response in Aseel chicken under free range, semi-intensive, and confinement rearing systems.

    Science.gov (United States)

    Rehman, M S; Mahmud, A; Mehmood, S; Pasha, T N; Hussain, J; Khan, M T

    2017-01-01

    A study was conducted to investigate the effects of 3 different rearing systems [free range ( FR: ), semi-intensive ( SI: ), and confinement ( CF: )] on blood biochemical profile and immune response in 4 varieties of Aseel chicken [Lakha ( LK: ), Mushki ( MS: ), Peshawari ( PW: ) and Sindhi ( SN: )] for 10 wk duration (7 to 16 wk). At the age of 6 wk, in total, 180 cockerels were assigned to 12 treatment groups, 3 (rearing system) × 4 (Aseel chicken variety) factorial arrangement in 7 randomized complete blocks, replicated 3 times with 5 birds in each replicate (45 birds of each variety; 60 birds in each rearing system; 36 total replicates). Blood samples were collected through brachial vein at the end of wk 16. After laboratory analysis, the recorded data for blood biochemical profile and immune response were analyzed by using 2-way ANOVA under factorial arrangement. The results showed higher (P birds under CF. Titer against Newcastle disease virus ( NDV: ) and infectious bronchitis virus ( IBV: ) was found to be greater (P birds indicated higher (P Birds of LK and SN varieties also indicated maximum antibody titer against NDV and IBV, respectively. Cholesterol level was found to be greater (P birds of LK and SN. Interaction of SN with FR revealed maximum (P birds; SI and FR confer maximum antibody titers to NDV and IBV. Birds of PW variety indicated higher glucose, total protein, albumin, uric acid, and creatinine, the lowest cholesterol under FR and the enhanced antibody titer against NDV and IBV. © 2016 Poultry Science Association Inc.

  14. Antioxidant status, immune system, blood metabolites and carcass ...

    African Journals Online (AJOL)

    This experiment was conducted to evaluate the effects of dietary turmeric rhizome powder (TP) on performance, blood metabolite, immune system, antioxidant status, and relative weight of organs in pre and post heat stressed broilers. Two hundred and sixty-four (264) day-old male Arian broiler chicks were randomly ...

  15. Freezing Baboon Red Blood Cells in the Original 800 ml Polyvinylchloride Plastic Bag With 40% W/V Glycerol and Storage at -80 C and Deglycerolization Using the IBM Code Blood Processor 2991

    National Research Council Canada - National Science Library

    1997-01-01

    ...) plastic collection bag. Up to four hundred fifty (450 + 45 ml) ml of blood is collected in a quadruple plastic bag system with a special adaptor port on the tubing connecting the primary 800 ml PVC plastic bag to the three transfer packs...

  16. [A capillary blood flow velocity detection system based on linear array charge-coupled devices].

    Science.gov (United States)

    Zhou, Houming; Wang, Ruofeng; Dang, Qi; Yang, Li; Wang, Xiang

    2017-12-01

    In order to detect the flow characteristics of blood samples in the capillary, this paper introduces a blood flow velocity measurement system based on field-programmable gate array (FPGA), linear charge-coupled devices (CCD) and personal computer (PC) software structure. Based on the analysis of the TCD1703C and AD9826 device data sheets, Verilog HDL hardware description language was used to design and simulate the driver. Image signal acquisition and the extraction of the real-time edge information of the blood sample were carried out synchronously in the FPGA. Then a series of discrete displacement were performed in a differential operation to scan each of the blood samples displacement, so that the sample flow rate could be obtained. Finally, the feasibility of the blood flow velocity detection system was verified by simulation and debugging. After drawing the flow velocity curve and analyzing the velocity characteristics, the significance of measuring blood flow velocity is analyzed. The results show that the measurement of the system is less time-consuming and less complex than other flow rate monitoring schemes.

  17. Donating Peripheral Blood Stem Cells

    Science.gov (United States)

    ... Print this page My Cart Donating peripheral blood stem cells Peripheral blood stem cell (PBSC) donation is a nonsurgical procedure to collect ... Donating bone marrow Donor experiences videos Peripheral blood stem cell (PBSC) donation is one of two methods of ...

  18. University of Washington Nuclear Physics Data Collection System

    International Nuclear Information System (INIS)

    Green, K.C.

    1981-01-01

    During the past several years, a new data collection system has been developed, replacing a previous system based on an SDS-930 computer. The system is constructed about a PDP 11/60 and an MBD-11 controlled CAMAC crate. The hardware configuration as well as a locally written singles data collection code will be described in some detail. Multiparameter data is taken with an enhanced version of Fermilab Multi. Current capabilities and future plans are discussed

  19. [The blood-brain barrier and drug delivery in the central nervous system].

    Science.gov (United States)

    Loch-Neckel, Gecioni; Koepp, Janice

    2010-08-01

    To provide an updated view of the difficulties due to barriers and strategies used to allow the release of drugs in the central nervous system. The difficulty for the treatment of many diseases of the central nervous system, through the use of intra-venous drugs, is due to the presence of barriers that prevent the release of the same: the blood-brain barrier, blood-cerebro-spinal fluid barrier and the blood-arachnoid barrier. The blood-brain barrier is the main barrier for the transport of drugs in the brain that also acts as a immunologic and metabolic barrier. The endothelial cells of the blood-brain barrier are connected to a junction complex through the interaction of transmembrane proteins that protrude from de inside to the outside, forming a connection between the endothelial cells. The transport of substances to the brain depends on the mechanisms of transport present in the barrier and the diffusion of these compounds also depends on the physicochemical characteristics of the molecule. Some diseases alter the permeability of the blood-brain barrier and thus the passage of drugs. Strategies such as the use of methods for drug delivery in the brain have been investigated. Further details regarding the mechanisms of transport across the blood-brain barrier and the changes in neuropathology would provide important information about the etiology of diseases and lead to better therapeutic strategies.

  20. 15 CFR 911.5 - NOAA Data Collection Systems Use Agreements.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false NOAA Data Collection Systems Use... POLICIES AND PROCEDURES CONCERNING USE OF THE NOAA SPACE-BASED DATA COLLECTION SYSTEMS § 911.5 NOAA Data Collection Systems Use Agreements. (a)(1) In order to use a NOAA DCS, each user must have an agreement with...

  1. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system.

    Science.gov (United States)

    Cao, Jing; Edwards, Rachel; Chairez, Janette; Devaraj, Sridevi

    2017-12-01

    Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory) was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics) was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer) for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing.

  2. Systems biology of stored blood cells: can it help to extend the expiration date?

    Science.gov (United States)

    Paglia, Giuseppe; Palsson, Bernhard Ø; Sigurjonsson, Olafur E

    2012-12-05

    With increasingly stringent regulations regarding deferral and elimination of blood donors it will become increasingly important to extend the expiration date of blood components beyond the current allowed storage periods. One reason for the storage time limit for blood components is that platelets and red blood cells develop a condition called storage lesions during their storage in plastic blood containers. Systems biology provides comprehensive bio-chemical descriptions of organisms through quantitative measurements and data integration in mathematical models. The biological knowledge for a target organism can be translated in a mathematical format and used to compute physiological properties. The use of systems biology represents a concrete solution in the study of blood cell storage lesions, and it may open up new avenues towards developing better storage methods and better storage media, thereby extending the storage period of blood components. This article is part of a Special Issue entitled: Integrated omics. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. The Impact of an Electronic Ordering System on Blood Bank Specimen Rejection Rates.

    Science.gov (United States)

    Forest, Stefanie K; Shirazi, Maryam; Wu-Gall, Charlotte; Stotler, Brie A

    2017-01-01

    To evaluate the impact that an electronic ordering system has on the rate of rejection of blood type and screen testing samples and the impact on the number of ABO blood-type discrepancies over a 4-year period. An electronic ordering system was implemented in May 2011. Rejection rates along with reasons for rejection were tracked between January 2010 and December 2013. A total of 40,104 blood samples were received during this period, of which 706 (1.8%) were rejected for the following reasons: 382 (54.0%) unsigned samples, 235 (33.0%) mislabeled samples, 57 (8.0%) unsigned requisitions, 18 (2.5%) incorrect tubes, and 14 (1.9%) ABO discrepancies. Of the samples, 2.5% were rejected in the year prior to implementing the electronic ordering system compared with 1.2% in the year following implementation ( P  blood sample rejection. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  4. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... in the field Hematology 2017 A collection of articles from the 2017 ASH Annual Meeting Education Program Blood: How I Treat A compendium of Blood articles updated to reflect the most recent scientific research ...

  5. Baseline extracellular potassium level as an indicator of the rate of increase of the same on further storage in CPDA-1 whole blood units: a potential approach to complement FIFO system for prioritisation of blood bags for release from blood-banks.

    Science.gov (United States)

    Baliarsingh, S; Jaiswal, M

    2014-02-01

    Potassium levels in stored blood bags increases as they age. Hyperkalemia in transfused blood has undesirable cardiac effects. Within a 19-month period, baseline and weekly samples from 15 CPDA-1 whole blood bags were collected till 28 days of storage and analysed for potassium, sodium, uric acid, albumin and whole blood haemoglobin. One unit increase in baseline (0 day) potassium in extracellular fluid of blood units was associated with the following increases in potassium levels on later days of storage: around two unit increase at 1 week (r2 = 0·50, P values. For CPDA-1 blood bags (i) low baseline potassium blood bags might be preferred for transfusion in cases demanding a low potassium load and (ii) coordinating the ‘first-in-first-out’ (FIFO) policy with ‘early release of blood-bags with high initial potassium’ might be helpful in improving the release of suitable blood units from blood-banks.

  6. Trends in the profile of blood donors at a large blood center in the city of São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Gonçalez Thelma

    2003-01-01

    Full Text Available OBJECTIVE: To describe the trends in the profile of blood donors from 1995 through 2001 at a large blood center in the city of São Paulo, Brazil, particularly following the initiation in 1998 of marketing strategies aimed at substituting replacement donors with altruistic repeat donors. METHODS: Using an information system that had been established at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo in 1994, we collected information on sex, age, and type of donation for the years 1995-2001. We classified blood donors as either replacement blood donors (if they stated that the reason for donating was that they had a friend or relative in the hospital or as altruistic donors. First-time blood donors were those who had not donated in our institution since the establishment of the information system. RESULTS: The percentage of repeat altruistic blood donors increased over time as first-time replacement donors declined for both genders. The proportion of altruistic donors climbed from 20% of all blood donors in 1995 to 57% in 2001. In 2001, first-time blood donors represented only 52% of all donors, as contrasted to 88% in 1995. Female donors increased from 20% to 37% of the donors over the period studied. CONCLUSIONS: Our data provide evidence that the São Paulo population has responded well to the marketing strategies that have been introduced in our institution. We believe that similar promotional efforts elsewhere in Brazil would produce comparable, positive results.

  7. System of data collection of muon super-telescope and neutron monitor

    International Nuclear Information System (INIS)

    Klepach, E.; Yanke, V.; Kryakunova, O.; Sarlanis, K.; Souvatsoglou, Zh.; Mavromichalaki, E.

    2005-01-01

    The system of collection of information, integrated with system of selection on concurrences which is easily modified and for collection of the neutron data for the multi directed telescopes and godoscopes is offered. The system of data collection completely is solved at program level on the basis of the super fast processor. Coincidences and decoding of directions of arrival of particles are executed at a program level, and also counters of impulses for necessary number of channels are organized. The system of data collection is executed as the universal external device. Depending on the loaded managing program, this device can be used as: 1) system of telescope data collection, combined with system of selection of double coincidences; or 2) 32-channel system of data collection, for example the neutron monitor; or 3) as the register of the multiple neutrons, generated in the neutron monitor. (author)

  8. Evaluation Of Blood Collected From Clinically Diagnosed Typhoid ...

    African Journals Online (AJOL)

    Blood culture revealed that 216 (42.8%) bacterial pathogens were isolated from the Widal positive patients yielded out of which 101 (46.8%) isolates were of ... fatal illness such as malaria and other parasitaemia, non-typhoid salmonellosis, endocarditis and other gastro-intestinal infections may have been responsible.

  9. Collection of heparinized plasma by plasmapheresis

    NARCIS (Netherlands)

    van der Meer, P. F.; Vrielink, H.; Pietersz, R. N.; Dekker, W. J.; Reesink, H. W.

    1999-01-01

    BACKGROUND AND OBJECTIVES: Heparinized plasma can be used for exchange transfusions in neonates and is usually collected by drawing whole blood using heparin as anticoagulant. The heparinized red blood cells and buffy coat cannot be used and are therefore discarded. To collect heparinized plasma

  10. Quantification of surgical blood loss.

    Science.gov (United States)

    Lee, Marcel H; Ingvertsen, Britt T; Kirpensteijn, Jolle; Jensen, Asger L; Kristensen, Annemarie T

    2006-06-01

    To compare gravimetric and colorimetric methods of quantifying surgical blood loss, and to determine if there is a correlation between preoperative hemostatic tests (buccal mucosa bleeding time [BMBT] and intraoperative blood loss). Prospective clinical study. Dogs (n=15) admitted for cutaneous tumor excision, orthopedic procedure, or exploratory laparotomy. Intraoperative blood loss was quantified by measuring irrigation fluid and weighing surgical sponges used for blood and fluid collection during surgery. Results of gravimetric measurements were then correlated to blood loss quantified using spectrophotometric analysis of hemoglobin (Hb) content. Hemostatic variables including BMBT were measured before surgery and compared with the calculated amount of blood loss. Blood loss quantified by gravimetric measurement showed a significant correlation with colorimetric determination of Hb content in surgical sponges and collected irrigation fluid (r=0.93, P<.0001). BMBT correlated weakly but significantly with intraoperative blood loss (r=0.56, P<.05). Quantifying intraoperative blood loss using spectrophotometric Hb analysis accurately assessed the amount of blood loss; however, it is a time-consuming procedure, primarily applicable as a research tool. Gravimetric evaluation of intraoperative blood loss was found to be an accurate method, which can be recommended for use in a clinical setting. Estimation of blood loss using a gravimetric method is accurate and applicable in the clinical setting and provides surgeons with a simple and objective tool to evaluate intraoperative blood loss.

  11. A clinical governance framework for blood services.

    Science.gov (United States)

    Williamson, L M; Benjamin, R J; Devine, D V; Katz, L M; Pink, J

    2015-05-01

    The elements of clinical governance, which ensure excellence in clinical care, can be applied to blood services. In this survey, their application in a range of blood providers was gauged, with the aim of identifying best practice and producing a generalizable framework. The Medical Directors of members of the Alliance of Blood Operators surveyed how different elements of clinical governance operated within their organizations and developed recommendations applicable in the blood service environment. The recommendations that emerged highlighted the importance of an organization's culture, with the delivery of optimal clinical governance being a corporate responsibility. Senior management must agree and promote a set of values to ensure that the system operates with the patient and donor at its heart. All staff should understand how their role fits into the 'journey to the patient', and a culture of openness promoted. Thus, reporting of errors and risks should be actively sought and praised, with penalties applied for concealment. Systems should exist to collect, analyse and escalate clinical outcomes, safety data, clinical risk assessments, incident reports and complaints to inform organizational learning. Clinical governance principles from general health care can be applied within blood services to complement good manufacturing practice. This requires leadership, accountability, an open culture and a drive for continuous improvement and excellence in clinical care. © 2015 International Society of Blood Transfusion.

  12. Adverse reactions to blood donations: the READ project.

    Science.gov (United States)

    Garozzo, Giovanni; Crocco, Isabella; Giussani, Barbara; Martinucci, Annalisa; Monacelli, Stefano; Randi, Vanda

    2010-01-01

    In 2006 in Italy 2,404,267 donations of blood components were made by 1,539,454 donors; approximately 55% of the donations were collected directly by Transfusion Structures (TS), while about 45% were collected in Donation Centres managed by Associations and Federations of Donors. The aim of the READ (Rilevamento Eventi Avversi alla Donazione) project is to create a network of TS to test a standardised system for monitoring adverse events (AE) related to blood donations. Shared, standardised data collection forms, compatible with the forms produced by the ISBT-EHN, were prepared. Two types of form were used: (i) a form to collect data on single events (READ 1), to be used at the individual collection sites; (ii) a form for processing the data collected by each TS (READ 2). Between February and August 2008 six TS collected data related to the donation of 89,332 units of blood. Overall, 523 AE were recorded. The AE occurred in 0.59% of the donations. The mean duration of the symptoms was 17 minutes. Fifteen percent of the symptoms were related to the venipuncture (mainly haematomas) and 77% to vasovagal AE. The AE were defined severe (grade C) in 47 cases. The donations in which AE were recorded were completed in 81% of the cases; 59% of the AE did not require treatment. Three donors were monitored briefly (for less than 4 hours) in hospital. The use of standardised forms enabled the collection of data that could be analysed. Some problems related to the performance of the haemovigilance programme did, however, emerge: (i) organisational problems, (ii) limited sensitivity, (iii) inadequate training, and (iv) poorly defined responsibilities. These problems must be resolved at various levels: local, regional and national.

  13. Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

    Directory of Open Access Journals (Sweden)

    Jing Cao

    2017-12-01

    Full Text Available Background: Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc. Methods: Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM 4000 (Instrumentation Laboratory was examined for Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pO2, pCO2, and pH, and correlation with serum tested on Vitros 5600 (Ortho Clinical Diagnostics was examined for creatinine. Eight paired capillary and venous blood was tested on epoc and ABL800 (Radiometer for the correlation of Na+, K+, Cl-, Ca2+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Capillary blood from 23 apparently healthy volunteers was tested on the epoc system to assess the concordance to reference ranges used locally. Results: Deming regression correlation coefficients for all the comparisons were above 0.65 except for ionized Ca2+. Accordance of greater than 85% to the local reference ranges were found in all assays with the exception of pO2 and Cl-. Conclusion: Data from this study indicates that capillary blood tests on the epoc system provide comparable results to reference method for these assays, Na+, K+, glucose, lactate, hematocrit, hemoglobin, pCO2, and pH. Further validation in critically ill patients is needed to implement the epoc system in patient transport. Impact of the study: This study demonstrated that capillary blood tests on the epoc Point of Care Blood Analysis System give comparable results to other chemistry analyzers for major blood gas and critical tests. The results are informative to institutions where pre-hospital and inter-hospital laboratory testing on capillary blood is a critical component of patient point of care testing. Keywords: Epoc, Capillary, Transport, Blood gas, Point of care

  14. Events at blood collection area due to nonconforming blood bags and plateletpheresis kits: need for timely corrective and preventive actions.

    Science.gov (United States)

    Verma, Anupam; Sachan, Deepti; Elhence, Priti; Pandey, Hem; Dubey, Anju

    2012-07-01

    Good blood banking practice requires that every effort should be made to detect any deviation or defect in blood bank products and to identify any potential risk to blood donor or recipient(s). We report the findings of an exercise that provide an insight into why feedback from the user side is crucial. Various events involving blood bags and plateletpheresis kits and the corresponding appropriate actions instituted for remedial measures were recorded. These scattered events were recorded for 6 months following the use of a new batch of improved blood bags with add-on features. Several events related to plateletpheresis kits from three different manufacturers were also recorded for 1 year. The affected blood bags were utilized with no untoward incident. The complaint was closed following satisfactory response from the blood bag manufacturing company that acted in a timely manner in addressing the root causes of the problems. However, corrective and preventive actions (CAPA) could not be implemented for plateletpheresis kits. The rate of undesirable events was higher with plateletpheresis kits as compared with whole blood bags (1.75% vs. 0.06%). As defects or deviations that trigger the need for CAPA can stem from numerous sources, it is important to clearly identify and document the problems and level of risk so that appropriate investigations can be instituted and remedial actions can be taken in a timely manner. This study demonstrates the usefulness of a quality initiative to collate and analyze blood product faults in conjunction with blood product manufacturers. © 2012 American Association of Blood Banks.

  15. Biochemical assessment of growth factors and circulation of blood components contained in the different fractions obtained by centrifugation of venous blood.

    Science.gov (United States)

    Corigiano, M; Ciobanu, G; Baldoni, E; Pompa, G

    2014-01-01

    The aim of this study was to evaluate a biochemical marker with different elements of a normal blood serum and centrifuged blood serum after a different rotation system. For this technique, we used five fractions of a blood Concentrated Growth Factors system (bCGF) and a particular device for the different rotation program. Blood samples were collected from 10 volunteers aged between 35 and 55 in the Operative Unit of the “Sapienza” University of Rome with only a fraction of different biochemical elements. Through an individual blood phase separator tube of venous blood, active factions of serum and 4 fractions of red buffy coat were taken. The biochemical markers with 14 elements were examined at times: P1-11 minutes, P2-12minutes, P3-15 minutes. Exclusively biological materials which are normally applied in the regeneration techniques for different defects and lesions were used with this technique. After specific rotation programs, a different result was obtained for each cycle: P1, P2, P3. In test tubes obtained by separated blood, we observed a higher concentration of proteins, ions, and other antigens compared to normal blood plasma. Examining the biochemical results of different elements, we observed an increase (P≤0,01). Since each person’s DNA is different, we could not have the same results in 5 fractions of blood concentration, we did, however, find a good increase in only a fraction of proteins, immunoglobulin and different ions. We obtained five fractions after centrifugation, and we had an increase in different biochemical elements compared to normal blood (P≤0,01) which is significant at different times. These biochemical elements were stimulated by different growth factors, which are used by the immune system, and they induced the formation of hard and soft tissues and good regeneration.

  16. The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals.

    Science.gov (United States)

    Willems, Elise; Smismans, Annick; Cartuyvels, Reinoud; Coppens, Guy; Van Vaerenbergh, Kristien; Van den Abeele, Anne-Marie; Frans, Johan

    2012-05-01

    Bloodstream infections remain a major challenge in medicine. Optimal detection of pathogens is only possible if the quality of preanalytical factors is thoroughly controlled. Since the laboratory is responsible for this preanalytical phase, the quality control of critical factors should be integrated in its quality control program. The numerous recommendations regarding blood culture collection contain controversies. Only an unambiguous guideline permits standardization and interlaboratory quality control. We present an evidence-based concise guideline of critical preanalytical determinants for blood culture collection and summarize key performance indicators with their concomitant target values. In an attempt to benchmark, we compared the true-positive rate, contamination rate, and collected blood volume of blood culture bottles in 5 Belgian hospital laboratories. The true-positive blood culture rate fell within previously defined acceptation criteria by Baron et al. (2005) in all 5 hospitals, whereas the contamination rate exceeded the target value in 4 locations. Most unexpected, in each of the 5 laboratories, more than one third of the blood culture bottles were incorrectly filled, irrespective of the manufacturer of the blood culture vials. As a consequence of this shortcoming, one manufacturer recently developed an automatic blood volume monitoring system. In conclusion, clear recommendations for standardized blood culture collection combined with quality control of critical factors of the preanalytical phase are essential for diagnostic blood culture improvement. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. The accuracy of self monitoring blood glucose meter systems in ...

    African Journals Online (AJOL)

    Many patients were referred to Kololo polyclinic laboratory to have their blood glucose checked because the values obtained on the patients' glucose meter systems did not tally with familiar clinical signs and symptoms. This prompted an experimental set up to check glucose meter systems using a larger number of patients.

  18. Barriers to Timely and Safe Blood Transfusion for PPH Patients: Evidence from a Qualitative Study in Dhaka, Bangladesh.

    Science.gov (United States)

    Akhter, Sadika; Anwar, Iqbal; Akter, Rashida; Kumkum, Feroza Akhter; Nisha, Monjura Khatun; Ashraf, Fatema; Islam, Ferdousi; Begum, Nazneen; Chowdhury, Mahbub Elahi; Austin, Anne; Islam, Syed Shariful; Rahman, Aminur

    2016-01-01

    In Bangladesh, postpartum hemorrhage (PPH) is the leading cause of maternal mortality accounting for 31% of all blood transfusions in the country. Although safe blood transfusion is one of the 8 signal functions of Comprehensive Emergency Obstetric Care (CEmOC) strategy, most of the designated public sector CEmOC facilities do not have on-site blood storage system. Emergent blood is mainly available from external blood banks. As a result, emergent patients are to rely on an unregulated network of brokers for blood which may raise question about blood safety. This study explored lived experiences of patients' attendants, managers, providers, and blood brokers before and after the implementation of an on-line Blood Information and Management Application (BIMA) in regards to barriers and facilitators of blood transfusion for emergent patients. Data were collected at Dhaka Medical College Hospital (DMCH), a tertiary-level teaching hospital before (January 2014) and after (March 2015) the introduction of an online BIMA system. Data collection methods included 24 key informant interviews (KIIs) and 40 in-depth interviews (IDIs). KIIs were conducted with formal health service providers, health managers and unlicensed blood brokers. IDIs were conducted with the relatives and husbands of women who suffered PPH, and needed emergency blood. Patients' attendants were unaware of patients' blood type and availability of blood in emergency situation. Newly introduced online BIMA system could facilitate blood transfusion process for poor patients at lower cost and during any time of day and night. However, service providers and service recipients were heavily dependent on a network of unlicensed blood brokers for required blood for emergent PPH patients. Blood collected through unlicensed blood brokers is un-screened, unregulated and probably unsafe. Blood brokers feel that they are providing a needed service, acknowledged a financial incentive and unaware about safety of blood

  19. Barriers to Timely and Safe Blood Transfusion for PPH Patients: Evidence from a Qualitative Study in Dhaka, Bangladesh.

    Directory of Open Access Journals (Sweden)

    Sadika Akhter

    Full Text Available In Bangladesh, postpartum hemorrhage (PPH is the leading cause of maternal mortality accounting for 31% of all blood transfusions in the country. Although safe blood transfusion is one of the 8 signal functions of Comprehensive Emergency Obstetric Care (CEmOC strategy, most of the designated public sector CEmOC facilities do not have on-site blood storage system. Emergent blood is mainly available from external blood banks. As a result, emergent patients are to rely on an unregulated network of brokers for blood which may raise question about blood safety. This study explored lived experiences of patients' attendants, managers, providers, and blood brokers before and after the implementation of an on-line Blood Information and Management Application (BIMA in regards to barriers and facilitators of blood transfusion for emergent patients.Data were collected at Dhaka Medical College Hospital (DMCH, a tertiary-level teaching hospital before (January 2014 and after (March 2015 the introduction of an online BIMA system. Data collection methods included 24 key informant interviews (KIIs and 40 in-depth interviews (IDIs. KIIs were conducted with formal health service providers, health managers and unlicensed blood brokers. IDIs were conducted with the relatives and husbands of women who suffered PPH, and needed emergency blood.Patients' attendants were unaware of patients' blood type and availability of blood in emergency situation. Newly introduced online BIMA system could facilitate blood transfusion process for poor patients at lower cost and during any time of day and night. However, service providers and service recipients were heavily dependent on a network of unlicensed blood brokers for required blood for emergent PPH patients. Blood collected through unlicensed blood brokers is un-screened, unregulated and probably unsafe. Blood brokers feel that they are providing a needed service, acknowledged a financial incentive and unaware about safety

  20. Comparison of the interleukin-1β-inducing potency of allergenic spores from higher fungi (Basidiomycetes) in a cryopreserved human whole blood system

    Science.gov (United States)

    Rivera-Mariani, Félix E.; Vysyaraju, Kranthi; Negherbon, Jesse; Levetin, Estelle; Horner, W. Elliot; Hartung, Thomas; Breysse, Patrick N.

    2014-01-01

    Background Spores from basidiomycete fungi (basidiospores) are highly prevalent in the atmosphere of urban and rural settings. Studies have confirmed their potential to affect human health as allergens. Less is known about their potential to serve as stimuli of the innate immune system and induce pro-inflammatory reactions. Methods In this study, we evaluated the pro-inflammatory potential of spores from 11 allergenic gilled (Pleurotus ostreatus, Oudemansiella radicata, Armillaria tabescens, Coprinus micaceus, Pluteus cervinus, Chlorophyllum molybdites) and non-gilled (Pisolithus arhizus, Merulius tremullosus, Calvatia cyathiformis, Lycoperdon pyriforme, Boletus bicolor) basidiomycetes fungi based on their potency to induce the release of the pro-inflammatory cytokine interleukin (IL)-1β in a cryopreserved human whole blood system. In addition, the role of morphological features of the spores (surface area, shape, and pigmentation) were examined for their role in the spores’ interleukin (IL)-1β-including potency. Peripheral blood from healthy volunteers was collected, pooled, and cryopreserved. After stimulating the cryopreserved pooled blood with 106 to 103 basidiospores/ml, the concentration of IL-1β in culture supernatants was determined with ELISA. Results Basidiospores manifested concentration-dependent IL-1β-inducing potency, which was more noteworthy among basidiospores from gilled basidiomycetes. At higher concentrations of basidiospores, the IL-1β-inducing potency was able to be differentiated in the cryopreserved human whole blood system. Morphological features did not correlate with the IL-1β-inducing potency of the basidiospores, suggesting that non-morphological properties modulate the IL-1β-inducing potency. Conclusion Our data provides evidence of the pro-inflammatory potential of basidiospores, and the utility of cryopreserved human whole blood as a human-based in-vitro system to study the immune reactivity of allergenic basidiospores. PMID

  1. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  2. The donor line break cannula: effect on the donation process, blood component quality and transfusion microbiology testing of an important new blood bag safety feature.

    Science.gov (United States)

    Nightingale, M J; Beard, M J; Bennett, J; Hambleton, R; Ramskill, S; Thomas, S

    2013-08-01

    The use of blood packs with an integral sampling system can result in anti-coagulant from the main bag reaching the sample pouch via the donor line, causing delayed coagulation of blood samples. In NHS Blood and Transplant, this has prevented the use of serum, the preferred matrix for transfusion microbiology (TM) testing, which has led to an increased false positive rate with ethylenediaminetetraacetic acid (EDTA) plasma. There is also a remote possibility of false negative results owing to sample dilution. Manufacturers have responded by offering packs with a donor line break cannula (DLBC) to prevent these adverse effects. The aims of this study were to assess the impact of DLBC packs on donation, blood component quality and of the potential return to serum for TM testing. DLBC packs from three manufacturers were assessed against control packs of the same dimensions and configuration. Donation duration, flow rate, platelet factor 4, prothrombin fragment 1+2, haemolysis and collection and processing incidents were compared. Results indicated no clinically significant adverse effect from the DLBC on the activation state of platelets, the coagulation cascade or increased haemolysis. Donation duration and blood collection and processing incident rates for DLBC packs were not significantly different to controls. The use of DLBC packs would reduce the complexity of manipulations during blood collection and therefore the likelihood of microbially contaminated donations (incorrect skin core diversion) and false negative TM tests. DLBC packs would enable the use of serum for TM testing with a significant reduction in false positive tests compared to EDTA plasma. © 2013 The Authors. Transfusion Medicine © 2013 British Blood Transfusion Society.

  3. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  4. Comparison of exercise blood pressure measured by technician and an automated system.

    Science.gov (United States)

    Garcia-Gregory, J A; Jackson, A S; Studeville, J; Squires, W G; Owen, C A

    1984-05-01

    We evaluated the automated system Blood Pressure Measuring System (BPMS) developed by NASA on 277 adult males who elected to have a treadmill test as part of their annual physical. The BPMS uses acoustic transduction with a computer-assisted ECG gating to detect nonsynchronous noise. The BPMS readings were compared to pressures simultaneously measured by trained technicians. For all stages of work, BPMS readings were higher for systolic and lower for diastolic than technician readings. At peak stages of work, BPMS systolic pressures were about 20 mmHg higher than technician readings. Within each 3-min workstage, BPMS readings were found to be more inconsistent than technician readings. The standard errors of measurement for BPMS were from two to three times higher than technician values. These data showed automated blood pressure readings were significantly different than technician values and subject to more random fluctuations. These findings demonstrate the need to view exercise blood pressure measured by automated systems with caution.

  5. Fresenius AS.TEC204 blood cell separator.

    Science.gov (United States)

    Sugai, Mikiya

    2003-02-01

    Fresenius AS.TEC204 is a third-generation blood cell separator that incorporates the continuous centrifugal separation method and automatic control of the cell separation process. Continuous centrifugation separates cell components according to their specific gravity, and different cell components are either harvested or eliminated as needed. The interface between the red blood cell and plasma is optically detected, and the Interface Control (IFC) cooperates with different pumps, monitors and detectors to harvest required components automatically. The system is composed of three major sections; the Front Panel Unit; the Pump Unit, and the Centrifuge Unit. This unit can be used for a wide variety of clinical applications including collection of platelets, peripheral blood stem cells, bone marrow stem cells, granulocytes, mononuclear cells, and exchange of plasma or red cells, and for plasma treatment.

  6. Remote Blood Glucose Monitoring in mHealth Scenarios: A Review

    Directory of Open Access Journals (Sweden)

    Giordano Lanzola

    2016-11-01

    Full Text Available Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient’s significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators.

  7. An Improved Method for Collection of Cerebrospinal Fluid from Anesthetized Mice

    DEFF Research Database (Denmark)

    Lim, Nastasia K-H; Moestrup, Visse Theresia Skov; Zhang, Xiao

    2017-01-01

    a technique that improves on current methods of collection to minimize contamination from blood and allow for the abundant collection of CSF (on average 10-15 µL can be collected). This technique can be used with other dissection methods for tissue collection from mice, as it does not impact any tissues......The cerebrospinal fluid (CSF) is a valuable body fluid for analysis in neuroscience research. It is one of the fluids in closest contact with the central nervous system and thus, can be used to analyze the diseased state of the brain or spinal cord without directly accessing these tissues. However......, in mice it is difficult to obtain from the cisterna magna due to its closeness to blood vessels, which often contaminate samples. The area for CSF collection in mice is also difficult to dissect to and often only small samples are obtained (maximum of 5-7 µL or less). This protocol describes in detail...

  8. Expression of manganese superoxide dismutase in rat blood, heart and brain during induced systemic hypoxia

    Directory of Open Access Journals (Sweden)

    Septelia I. Wanandi

    2011-02-01

    Full Text Available Background: Hypoxia results in an increased generation of ROS. Until now, little is known about the role of MnSOD - a major endogenous antioxidant enzyme - on the cell adaptation response against hypoxia. The aim of this study was to  determine the MnSOD mRNA expression and levels of specific activity in blood, heart and brain of rats during induced systemic hypoxia.Methods: Twenty-five male Sprague Dawley rats were subjected to systemic hypoxia in an hypoxic chamber (at 8-10% O2 for 0, 1, 7, 14 and 21 days, respectively. The mRNA relative expression of MnSOD was analyzed using Real Time RT-PCR. MnSOD specific activity was determined using xanthine oxidase inhibition assay.Results: The MnSOD mRNA relative expression in rat blood and heart was decreased during early induced systemic hypoxia (day 1 and increased as hypoxia continued, whereas the mRNA expression in brain was increased since day 1 and reached its maximum level at day 7. The result of MnSOD specific activity during early systemic hypoxia was similar to the mRNA expression. Under very late hypoxic condition (day 21, MnSOD specific activity in blood, heart and brain was significantly decreased. We demonstrate a positive correlation between MnSOD mRNA expression and specific activity in these 3 tissues during day 0-14 of induced systemic hypoxia. Furthermore, mRNA expression and specific activity levels in heart strongly correlate with those in blood.Conclusion: The MnSOD expression at early and late phases of induced systemic hypoxia is distinctly regulated. The MnSOD expression in brain differs from that in blood and heart revealing that brain tissue can  possibly survive better from induced systemic hypoxia than heart and blood. The determination of MnSOD expression in blood can be used to describe its expression in heart under systemic hypoxic condition. (Med J Indones 2011; 20:27-33Keywords: MnSOD, mRNA expression, ROS, specific activity, systemic hypoxia

  9. Hospital blood bank information systems accurately reflect patient transfusion: results of a validation study.

    Science.gov (United States)

    McQuilten, Zoe K; Schembri, Nikita; Polizzotto, Mark N; Akers, Christine; Wills, Melissa; Cole-Sinclair, Merrole F; Whitehead, Susan; Wood, Erica M; Phillips, Louise E

    2011-05-01

    Hospital transfusion laboratories collect information regarding blood transfusion and some registries gather clinical outcomes data without transfusion information, providing an opportunity to integrate these two sources to explore effects of transfusion on clinical outcomes. However, the use of laboratory information system (LIS) data for this purpose has not been validated previously. Validation of LIS data against individual patient records was undertaken at two major centers. Data regarding all transfusion episodes were analyzed over seven 24-hour periods. Data regarding 596 units were captured including 399 red blood cell (RBC), 95 platelet (PLT), 72 plasma, and 30 cryoprecipitate units. They were issued to: inpatient 221 (37.1%), intensive care 109 (18.3%), outpatient 95 (15.9%), operating theater 45 (7.6%), emergency department 27 (4.5%), and unrecorded 99 (16.6%). All products recorded by LIS as issued were documented as transfused to intended patients. Median time from issue to transfusion initiation could be calculated for 535 (89.8%) components: RBCs 16 minutes (95% confidence interval [CI], 15-18 min; interquartile range [IQR], 7-30 min), PLTs 20 minutes (95% CI, 15-22 min; IQR, 10-37 min), fresh-frozen plasma 33 minutes (95% CI, 14-83 min; IQR, 11-134 min), and cryoprecipitate 3 minutes (95% CI, -10 to 42 min; IQR, -15 to 116 min). Across a range of blood component types and destinations comparison of LIS data with clinical records demonstrated concordance. The difference between LIS timing data and patient clinical records reflects expected time to transport, check, and prepare transfusion but does not affect the validity of linkage for most research purposes. Linkage of clinical registries with LIS data can therefore provide robust information regarding individual patient transfusion. This enables analysis of joint data sets to determine the impact of transfusion on clinical outcomes. © 2010 American Association of Blood Banks.

  10. Platelet-rich fibrin prepared from stored whole-blood samples.

    Science.gov (United States)

    Isobe, Kazushige; Suzuki, Masashi; Watanabe, Taisuke; Kitamura, Yutaka; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2017-12-01

    In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Blood samples were collected from non-smoking, healthy male donors (aged 27-67 years, N = 6), and PRF clots were prepared immediately or after storage for 1-2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Addition of optimal amounts of a 10% CaCl 2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.

  11. Stem cells of umbilical blood cord – therapeutic use

    Directory of Open Access Journals (Sweden)

    Beata Bielec

    2015-07-01

    Full Text Available For many years, the transplantation of hematopoietic stem cells has been used to treat some diseases of the hematopoietic system. For a very long time, only bone marrow was used as a source of hematopoietic stem cells for this method of treatment. However, to comply with allogeneic bone marrow transplantation, an antigenically compatible donor is necessary. Transplantations from unrelated donors are associated with increased risk of a graft-versus-host reaction, transplant rejection and, consequently, increased mortality. Many years ago, it was found that umbilical cord blood as well as bone marrow and peripheral blood contains hematopoietic stem cells and mesenchymal cells able to differentiate into different cell types and that the umbilical cord blood can be a source of stem cells for transplantation. Following this discovery, numerous attempts were made for its potential use in the treatment of hematologic diseases, metabolic diseases as well as regenerative medicine. Umbilical cord blood stem cells exhibit intermediate characteristics between embryonic and adult stem cells. They are distinguished from the latter by telomere length, telomerase activity, and lower risk of accumulation of DNA mutations or chromosomal aberrations. The only transplantation limitation appears to be the amount of cord blood collected, which on average is sufficient for transplantation in a 40-50 kg child. Collection of cord blood is a simple, short-lasting treatment, not causing any danger for a newborn or the mother. Umbilical cord blood is obtained during labor, and then frozen and stored at cord blood banks all over the world.

  12. Postoperative blood salvage versus allogeneic blood transfusion in total knee and hip arthroplasty: a literature review.

    Science.gov (United States)

    Leigheb, Massimiliano; Pogliacomi, Francesco; Bosetti, Michela; Boccafoschi, Francesca; Sabbatini, Maurizio; Cannas, Mario; Grassi, Federico

    2016-04-15

    We aimed to compare Postoperative Blood Salvage (PBS) with Allogeneic Blood Transfusion (ABT) in patients undergoing Total Hip and Knee Arthroplasty (THA, TKA).  A bibliographic research was carried out in order to review the literature dedicated to postoperative blood salvage in major orthopaedic surgery, excluding papers dealing exclusively with preoperative autologous donation, intraoperative blood salvage and ABT. PBS and ABT were compared according to complications, costs and duration of hospitalization. PBS effectiveness in reducing ABT was also assessed. PBS system is useful for reducing the complication rate and the length of hospital stay if compared to ABT. Costs for the reinfusion of unwashed shed blood, washed blood, and allogeneic transfusion are controversial among the different authors. Several papers demonstrate that PBS significantly reduces the need of postoperative ABT in both THA and TKA, while there is low evidence that PBS does not affect the risk of surgical wound complications. To reduce potential risks related to PBS, including non-hemolytic febrile reaction, the reinfusion of saved blood should begin within 4-6 hours after the start of collection through the wound drainage. According to literature, PBS appears to be a valid alternative to ABT, which is the standard treatment for postoperative anemia in THA and TKA. Contraindications to PBS must be ruled out before recommending it to patients undergoing major orthopaedic procedures.

  13. micROS: a morphable, intelligent and collective robot operating system.

    Science.gov (United States)

    Yang, Xuejun; Dai, Huadong; Yi, Xiaodong; Wang, Yanzhen; Yang, Shaowu; Zhang, Bo; Wang, Zhiyuan; Zhou, Yun; Peng, Xuefeng

    2016-01-01

    Robots are developing in much the same way that personal computers did 40 years ago, and robot operating system is the critical basis. Current robot software is mainly designed for individual robots. We present in this paper the design of micROS, a morphable, intelligent and collective robot operating system for future collective and collaborative robots. We first present the architecture of micROS, including the distributed architecture for collective robot system as a whole and the layered architecture for every single node. We then present the design of autonomous behavior management based on the observe-orient-decide-act cognitive behavior model and the design of collective intelligence including collective perception, collective cognition, collective game and collective dynamics. We also give the design of morphable resource management, which first categorizes robot resources into physical, information, cognitive and social domains, and then achieve morphability based on self-adaptive software technology. We finally deploy micROS on NuBot football robots and achieve significant improvement in real-time performance.

  14. [Prospects in blood transfusion].

    Science.gov (United States)

    Rouger, P

    2003-04-01

    What will be the evolution of blood transfusion in the next 10 years? What are the scientific and medical arguments to help the decision makers to propose the developments? Many scientific and clinical studies show that blood substitutes are not ready for use in man. So, for a long time, blood collection in man will still be a necessity to prepare cell concentrates (red blood cells and platelets) and fresh frozen plasma. During this period, blood safety will be based on development of testing technics and preparation processes of blood products. Another major point will be a better clinical use of blood derivates. Cellular therapy will be probably only a way of diversification in blood transfusion centers in partnership with hospitals.

  15. Redesigning a collection system for "small" consumer electronics

    NARCIS (Netherlands)

    Melissen, Franciscus

    2006-01-01

    This paper establishes that the collection system within the recycling scheme for consumer electronics in the Netherlands has not been entirely successful in convincing consumers to hand in their used appliances by means of dedicated collection routes. Particularly regarding small appliances,

  16. Optimizing preoperative blood ordering with data acquired from an anesthesia information management system.

    Science.gov (United States)

    Frank, Steven M; Rothschild, James A; Masear, Courtney G; Rivers, Richard J; Merritt, William T; Savage, Will J; Ness, Paul M

    2013-06-01

    The maximum surgical blood order schedule (MSBOS) is used to determine preoperative blood orders for specific surgical procedures. Because the list was developed in the late 1970s, many new surgical procedures have been introduced and others improved upon, making the original MSBOS obsolete. The authors describe methods to create an updated, institution-specific MSBOS to guide preoperative blood ordering. Blood utilization data for 53,526 patients undergoing 1,632 different surgical procedures were gathered from an anesthesia information management system. A novel algorithm based on previously defined criteria was used to create an MSBOS for each surgical specialty. The economic implications were calculated based on the number of blood orders placed, but not indicated, according to the MSBOS. Among 27,825 surgical cases that did not require preoperative blood orders as determined by the MSBOS, 9,099 (32.7%) had a type and screen, and 2,643 (9.5%) had a crossmatch ordered. Of 4,644 cases determined to require only a type and screen, 1,509 (32.5%) had a type and crossmatch ordered. By using the MSBOS to eliminate unnecessary blood orders, the authors calculated a potential reduction in hospital charges and actual costs of $211,448 and $43,135 per year, respectively, or $8.89 and $1.81 per surgical patient, respectively. An institution-specific MSBOS can be created, using blood utilization data extracted from an anesthesia information management system along with our proposed algorithm. Using these methods to optimize the process of preoperative blood ordering can potentially improve operating room efficiency, increase patient safety, and decrease costs.

  17. Can gingival crevicular blood be relied upon for assessment of blood glucose level?

    Science.gov (United States)

    Dwivedi, Shivani; Verma, Sharmila J; Shah, Monali; Jain, Kapil

    2014-11-01

    Diabetes mellitus (DM) is undiagnosed in approximately half of the patients actually suffering from the disease. In addition, the prevalence of DM is more than twice as high as in patients with periodontitis when compared to periodontally healthy subjects. Thus, a high number of patients with periodontitis may have undiagnosed DM. The purpose of the present study was to evaluate whether blood oozing from a gingival crevice during routine periodontal examination can be used for determining glucose levels. Observational cross-sectional studies were carried out in 75 patients (43 males and 32 females) with chronic periodontitis who were divided into two groups: Group I and Group II, respectively. Blood oozing from the gingival crevices of anterior teeth following periodontal probing was collected with the stick of glucose self-monitoring device, and the blood glucose levels were measured. At the same time, finger-prick blood was taken for glucometric analysis and subsequent readings were recorded. The patient's blood glucose values ranged from 74 to 256 mg/dl. The comparison between gingival crevicular blood and finger-prick blood showed a very strong correlation, with a t value of 3.97 (at P value = 0.001). The data from this study has shown that GCB collected during diagnostic periodontal examination can be an excellent source of blood for glucometric analysis.

  18. Cold Vacuum Drying facility condensate collection system design description

    International Nuclear Information System (INIS)

    PITKOFF, C.C.

    1999-01-01

    This document describes the Cold Vacuum Drying Facility (CVDF) condensate collection system (CCS). The function of the CCS is to collect cooling coil condensate from air-handling units in the CVDF and to isolate the condensate in collection tanks until the condensate is determined to be acceptable to drain to the effluent drain collection basin

  19. Screening of gingival crevicular blood glucose and capillary finger blood glucose in the diagnosis of diabetes

    Directory of Open Access Journals (Sweden)

    Alka S Waghmare

    2011-01-01

    Full Text Available Aim: The study aimed at obtaining glucose readings using gingival crevicular blood (GCB to screen for undiagnosed diabetes during routine dental visits. Materials and Methods: The present study included 50 patients who were divided into two groups, i.e. Group A and Group B, based on bleeding on probing at the site of collection of GCB. Group A participants had blood collected from sites having adequate bleeding on probing, whereas Group B participants had blood collected from sites with little bleeding on probing. GCB and capillary finger-stick blood (CFB] glucose readings were obtained using a self-monitoring glucometer. Statistical Analysis: Correlations between both the samples were done using Pearson′s correlation. Results: Group A patients′ correlations between GCB and CFB glucose readings were high, whereas in Group B patients, correlations between glucose readings were low. Conclusion: GCB can be an excellent source for screening diabetes during routine dental visits.

  20. Large-scale clinical comparison of the lysis-centrifugation and radiometric systems for blood culture

    International Nuclear Information System (INIS)

    Brannon, P.; Kiehn, T.E.

    1985-01-01

    The Isolator 10 lysis-centrifugation blood culture system (E. I. du Pont de Nemours and Co., Inc., Wilmington, Del.) was compared with the BACTEC radiometric method (Johnston Laboratories, Inc., Towson, Md.) with 6B and 7D broth media for the recovery of bacteria and yeasts. From 11,000 blood cultures, 1,174 clinically significant organisms were isolated. The Isolator system recovered significantly more total organisms, members of the family Enterobacteriaceae, Staphylococcus spp., and yeasts. The BACTEC system recovered significantly more Pseudomonas spp., Streptococcus spp., and anaerobes. Of the Isolator colony counts, 87% measured less than 11 CFU/ml of blood. Organisms, on an average, were detected the same day from each of the two culture systems. Only 13 of the 975 BACTEC isolates (0.01%) were recovered by subculture of growth-index-negative bottles, and 12 of the 13 were detected in another broth blood culture taken within 24 h. Contaminants were recovered from 4.8% of the Isolator 10 and 2.3% of the BACTEC cultures

  1. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients.

    Science.gov (United States)

    Kanadani, Fabio N; Figueiredo, Carlos R; Miranda, Rafaela Morais; Cunha, Patricia Lt; M Kanadani, Tereza Cristina; Dorairaj, Syril

    2015-01-01

    Glaucomatous neuropathy can be a consequence of insufficient blood supply, increase in intraocular pressure (IOP), or other risk factors that diminish the ocular blood flow. To determine the ocular perfusion pressure (OPP) in normal and systemic hypertensive patients. One hundred and twenty-one patients were enrolled in this prospective and comparative study and underwent a complete ophthalmologic examination including slit lamp examination, Goldmann applanation tonometry, stereoscopic fundus examination, and pulsatile ocular blood flow (POBF) measurements. The OPP was calculated as being the medium systemic arterial pressure (MAP) less the IOP. Only right eye values were considered for calculations using Student's t-test. The mean age of the patients was 57.5 years (36-78), and 68.5% were women. There was a statistically significant difference in the OPP of the normal and systemic hypertensive patients (p cite this article: Kanadani FN, Figueiredo CR, Miranda RM, Cunha PLT, Kanadani TCM, Dorairaj S. Ocular Perfusion Pressure and Pulsatile Ocular Blood Flow in Normal and Systemic Hypertensive Patients. J Curr Glaucoma Pract 2015;9(1):16-19.

  2. Blood transfusion safety; current status and challenges in Nigeria

    Directory of Open Access Journals (Sweden)

    John C Aneke

    2017-01-01

    Full Text Available The attainment of blood transfusion safety in Nigeria (and probably the rest of Sub-Saharan Africa remains an uphill task due to a number of factors, ranging from shortage of blood, poor implementation of blood transfusion guidelines, infrastructural deficits to high prevalence of transfusion-transmissible infections (TTIs, particularly hepatitis and human immune deficiency viruses. We reviewed available data on blood transfusion practices and safety in Nigeria using the PubMed, PubMed Central, Google Scholar, and African Index Medicus search engines, through a combination of word and phrases relevant to the subject. The World Health Organization has been in the forefront of efforts to establish safe, available, and affordable blood transfusion services in most parts of Africa through encouraging adequate blood donor recruitment, donor blood testing, and collection as well developing strategies for the rational use of blood. Even though modest improvement has been recorded, particularly with regards to donor blood screening for common TTIs, considerable efforts are needed in the form of robust public enlightenment campaigns (on blood donation and continuous system improvement to drive the current transfusion practices in the country toward safety and self-sustenance.

  3. Computed aided system for separation and classification of the abnormal erythrocytes in human blood

    Science.gov (United States)

    Wąsowicz, Michał; Grochowski, Michał; Kulka, Marek; Mikołajczyk, Agnieszka; Ficek, Mateusz; Karpieńko, Katarzyna; Cićkiewicz, Maciej

    2017-12-01

    The human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified diamonds and oxidation modified. The blood was put under an impact of two diamond concentrations: 20μl and 100μl. The amount of abnormal cells increased with time. The percentage of echinocytes as a result of interaction with nanodiamonds in various time intervals for individual specimens was scarce. The impact of the two diamond types had no clinical importance on red blood cells. It is supposed that as a result of longlasting exposure a dehydratation of red cells takes place, because of the function of the cells. The analysis of an influence of nanodiamond particles on blood elements was supported by computer system designed for automatic counting and classification of the Red Blood Cells (RBC). The system utilizes advanced image processing methods for RBCs separation and counting and Eigenfaces method coupled with the neural networks for RBCs classification into normal and abnormal cells purposes.

  4. Processing and storage of blood components: strategies to improve patient safety

    Directory of Open Access Journals (Sweden)

    Pietersz RNI

    2015-08-01

    Full Text Available Ruby NI Pietersz, Pieter F van der Meer Department of Product and Process Development, Sanquin Blood Bank, Amsterdam, the Netherlands Abstract: This review focuses on safety improvements of blood processing of various blood components and their respective storage. A solid quality system to ensure safe and effective blood components that are traceable from a donor to the patient is the foundation of a safe blood supply. To stimulate and guide this process, National Health Authorities should develop guidelines for blood transfusion, including establishment of a quality system. Blood component therapy enabled treatment of patients with blood constituents that were missing, only thus preventing reactions to unnecessarily transfused elements. Leukoreduction prevents many adverse reactions and also improves the quality of the blood components during storage. The safety of red cells and platelets is improved by replacement of plasma with preservative solutions, which results in the reduction of isoantibodies and plasma proteins. Automation of blood collection, separation of whole blood into components, and consecutive processing steps, such as preparation of platelet concentrate from multiple donations, improves the consistent composition of blood components. Physicians can better prescribe the number of transfusions and therewith reduce donor exposure and/or the risk of pathogen transmission. Pathogen reduction in cellular blood components is the latest development in improving the safety of blood transfusions for patients. Keywords: blood components, red cell concentrates, platelet concentrates, plasma, transfusion, safety 

  5. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  6. Hyperspectral imaging and multivariate analysis in the dried blood spots investigations

    Science.gov (United States)

    Majda, Alicja; Wietecha-Posłuszny, Renata; Mendys, Agata; Wójtowicz, Anna; Łydżba-Kopczyńska, Barbara

    2018-04-01

    The aim of this study was to apply a new methodology using the combination of the hyperspectral imaging and the dry blood spot (DBS) collecting. Application of the hyperspectral imaging is fast and non-destructive. DBS method offers the advantage also on the micro-invasive blood collecting and low volume of required sample. During experimental step, the reflected light was recorded by two hyperspectral systems. The collection of 776 spectral bands in the VIS-NIR range (400-1000 nm) and 256 spectral bands in the SWIR range (970-2500 nm) was applied. Pixel has the size of 8 × 8 and 30 × 30 µm for VIS-NIR and SWIR camera, respectively. The obtained data in the form of hyperspectral cubes were treated with chemometric methods, i.e., minimum noise fraction and principal component analysis. It has been shown that the application of these methods on this type of data, by analyzing the scatter plots, allows a rapid analysis of the homogeneity of DBS, and the selection of representative areas for further analysis. It also gives the possibility of tracking the dynamics of changes occurring in biological traces applied on the surface. For the analyzed 28 blood samples, described method allowed to distinguish those blood stains because of time of apply.

  7. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    Science.gov (United States)

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (pair space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (ptransport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (ptransport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Affirmative Action Data Collection and Reporting System.

    Science.gov (United States)

    McLean, Marquita; And Others

    A computerized Affirmative Action Data Collection and Reporting System was implemented at the University of Cincinnati to assist in monitoring the progress of the University's Affirmative Action program. The benefits derived from the system were definitely a contributing factor in the University's successful attempt to have its Affirmative Action…

  9. Order of blood draw

    DEFF Research Database (Denmark)

    Cornes, Michael; van Dongen-Lases, Edmée; Grankvist, Kjell

    2017-01-01

    does occur if order of draw is not followed during blood collection and when performing venipuncture under less than ideal circumstances, thus putting patient safety at risk. Moreover, given that order of draw is not difficult to follow and knowing that ideal phlebotomy conditions and protocols...... Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) provides an overview and summary of the literature with regards to order of draw in venous blood collection. Given the evidence presented in this article, the EFLM WG-PRE herein concludes that a significant frequency of sample contamination...

  10. 21 CFR 864.9145 - Processing system for frozen blood.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Processing system for frozen blood. 864.9145 Section 864.9145 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture...

  11. Hydrophobic/Hydrophilic Cooperative Janus System for Enhancement of Fog Collection.

    Science.gov (United States)

    Cao, Moyuan; Xiao, Jiasheng; Yu, Cunming; Li, Kan; Jiang, Lei

    2015-09-09

    Harvesting micro-droplets from fog is a promising method for solving global freshwater crisis. Different types of fog collectors have been extensively reported during the last decade. The improvement of fog collection can be attributed to the immediate transportation of harvested water, the effective regeneration of the fog gathering surface, etc. Through learning from the nature's strategy for water preservation, the hydrophobic/hydrophilic cooperative Janus system that achieved reinforced fog collection ability is reported here. Directional delivery of the surface water, decreased re-evaporation rate of the harvested water, and thinner boundary layer of the collecting surface contribute to the enhancement of collection efficiency. Further designed cylinder Janus collector can facilely achieve a continuous process of efficient collection, directional transportation, and spontaneous preservation of fog water. This Janus fog harvesting system should improve the understanding of micro-droplet collection system and offer ideas to solve water resource crisis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Effect of adhesive properties of buffy coat on the quality of blood components produced with Top & Top and Top & Bottom bags.

    Science.gov (United States)

    Cerelli, Eugenio; Nocera, Martina; Di Bartolomeo, Erminia; Panzani, Paola; Baricchi, Roberto

    2015-04-01

    The Transfusion Medicine Unit of Reggio Emilia currently collects whole blood using conventional quadruple Fresenius Top & Top bags. In this study, new Fresenius Top & Bottom bags were assessed and compared to the routine method with regards to product quality and operational requirements. Twenty-one whole blood units were collected with both the new and the traditional bags, and then separated. Quality control data were evaluated and compared in order to estimate yield and quality of final blood components obtained with the two systems. We collected other bags, not included in the ordinary quality control programme, for comparison of platelet concentrates produced by pools of buffy coat. Compared to the traditional system, the whole blood units processed with Top & Bottom bags yielded larger plasma volumes (+5.7%) and a similar amount of concentrated red blood cells, but with a much lower contamination of lymphocytes (-61.5%) and platelets (-86.6%). Consequently, the pooled platelets contained less plasma (-26.3%) and were significantly richer in platelets (+17.9%). This study investigated the effect of centrifugation on the adhesiveness of the buffy coat to the bag used for whole blood collection. We analysed the mechanism by which this undesirable phenomenon affects the quality of packed red blood cells in two types of bags. We also documented the incomparability of measurements on platelet concentrates performed with different principles of cell counting: this vexing problem has important implications for biomedical research and for the establishment of universal product standards. Our results support the conclusion that the Top & Bottom bags produce components of higher quality than our usual system, while having equal operational efficiency. Use of the new bags could result in an important quality improvement in blood components manufacturing.

  13. The influence of institutions and organizations on urban waste collection systems: an analysis of waste collection system in Accra, Ghana (1985-2000).

    Science.gov (United States)

    Fobil, Julius N; Armah, Nathaniel A; Hogarh, Jonathan N; Carboo, Derick

    2008-01-01

    Urban waste collection system is a pivotal component of all waste management schemes around the world. Therefore, the efficient performance and the success of these schemes in urban pollution control rest on the ability of the collection systems to fully adapt to the prevailing cultural and social contexts within which they operate. Conceptually, institutions being the rules guiding the conduct of public service provision and routine social interactions, waste collection systems embedded in institutions can only realize their potentials if they fully evolve continuously to reflect evolving social and technical matrices underlying the cultures, organizations, institutions and social conditions they are designed to address. This paper is a product of an analysis of waste collection performance in Ghana under two different institutional and/or organizational regimes; from an initial entirely public sector dependence to a current mix of public-private sector participation drawing on actual planning data from 1985 to 2000. The analysis found that the overall performance of waste collection services in Ghana increased under the coupled system, with efficiency (in terms of total waste clearance and coverage of service provision) increasing rapidly with increased private-sector controls and levels of involvement, e.g. for solid waste, collection rate and disposal improved from 51% in 1998 to about 91% in the year 2000. However, such an increase in performance could not be sustained beyond 10 years of public-private partnerships. This analysis argues that the sustainability of improved waste collection efficiency is a function of the franchise and lease arrangements between private sector group on the one hand and public sector group (local authorities) on the other hand. The analysis therefore concludes that if such franchise and lease arrangements are not conceived out of an initial transparent process, such a provision could undermine the overall sustainability of

  14. Knowledge-based fault diagnosis system for refuse collection vehicle

    International Nuclear Information System (INIS)

    Tan, CheeFai; Juffrizal, K.; Khalil, S. N.; Nidzamuddin, M. Y.

    2015-01-01

    The refuse collection vehicle is manufactured by local vehicle body manufacturer. Currently; the company supplied six model of the waste compactor truck to the local authority as well as waste management company. The company is facing difficulty to acquire the knowledge from the expert when the expert is absence. To solve the problem, the knowledge from the expert can be stored in the expert system. The expert system is able to provide necessary support to the company when the expert is not available. The implementation of the process and tool is able to be standardize and more accurate. The knowledge that input to the expert system is based on design guidelines and experience from the expert. This project highlighted another application on knowledge-based system (KBS) approached in trouble shooting of the refuse collection vehicle production process. The main aim of the research is to develop a novel expert fault diagnosis system framework for the refuse collection vehicle

  15. Knowledge-based fault diagnosis system for refuse collection vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Tan, CheeFai; Juffrizal, K.; Khalil, S. N.; Nidzamuddin, M. Y. [Centre of Advanced Research on Energy, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, Durian Tunggal, Melaka (Malaysia)

    2015-05-15

    The refuse collection vehicle is manufactured by local vehicle body manufacturer. Currently; the company supplied six model of the waste compactor truck to the local authority as well as waste management company. The company is facing difficulty to acquire the knowledge from the expert when the expert is absence. To solve the problem, the knowledge from the expert can be stored in the expert system. The expert system is able to provide necessary support to the company when the expert is not available. The implementation of the process and tool is able to be standardize and more accurate. The knowledge that input to the expert system is based on design guidelines and experience from the expert. This project highlighted another application on knowledge-based system (KBS) approached in trouble shooting of the refuse collection vehicle production process. The main aim of the research is to develop a novel expert fault diagnosis system framework for the refuse collection vehicle.

  16. Collection of master-slave synchronized chaotic systems

    NARCIS (Netherlands)

    Lerescu, AI; Constandache, N; Oancea, S; Grosu, [No Value

    2004-01-01

    In this work the open-plus-closed-loop (OPCL) method of synchronization is used in order to synchronize the systems from the Sprott's collection of the simplest chaotic systems. The method is general and we looked for the simplest coupling between master and slave. The main result is that for the

  17. [Development of an automatic pneumatic tourniquet system that determines pressures in synchrony with systolic blood pressure].

    Science.gov (United States)

    Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong

    2012-11-01

    The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.

  18. Implementation of a comprehensive blood conservation program can reduce blood use in a community cardiac surgery program.

    Science.gov (United States)

    Xydas, Steve; Magovern, Christopher J; Slater, James P; Brown, John M; Bustami, Rami; Parr, Grant V; Thurer, Robert L

    2012-04-01

    The study objective was to determine the effects of implementing a blood conservation algorithm on blood product use and outcomes in a community cardiac surgery program. A blood management strategy including lower hemoglobin transfusion threshold and algorithm-driven decisions was adopted. Intraoperatively, point-of-care testing was used to avoid inappropriate component transfusion. A low prime perfusion circuit was adopted. Blood was withdrawn from patients before initiating bypass when possible. Patients undergoing coronary and valve procedures were included. Outlier patients receiving more than 10 units packed red blood cells were excluded. Data were collected for 6 months as a baseline group (group I). A 3-month period of program implementation was allotted. Data were subsequently collected for 6 months and comprised the study patients (group II). Prospective data were collected on demographics, blood use, and outcomes. Group I comprised 481 patients, and group II comprised 551 patients. Group II received fewer units of packed red blood cells, fresh-frozen plasma, and cryoprecipitate than group I. There was no difference in platelets transfused. Total blood product use was reduced by 40% in group II (P conservation algorithm can be rapidly introduced, leading to reductions in blood and component use with no detrimental effect on early outcomes. Point-of-care testing can direct component transfusion in coagulopathic cases, with most coagulopathic patients requiring platelets. Further research will determine the effects of reduced transfusions on long-term outcomes. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  19. Isolation of mesenchymal stem cells from equine umbilical cord blood

    DEFF Research Database (Denmark)

    Koch, Thomas Gadegaard; Heerkens, Tammy; Thomsen, Preben Dybdahl

    2007-01-01

    . The hypothesis of this study was that equine MSCs could be isolated from fresh whole equine cord blood. Results: Cord blood was collected from 7 foals immediately after foaling. The mononuclear cell fraction was isolated by Ficoll density centrifugation and cultured in a DMEM low glucose based media at 38.5o......Background: There are no published studies on stem cells from equine cord blood although commercial storage of equine cord blood for future autologous stem cell transplantations is available. Mesenchymal stem cells (MSC) have been isolated from fresh umbilical cord blood of humans collected non......-invasively at the time of birth and from sheep cord blood collected invasively by a surgical intrauterine approach. Mesenchymal stem cells isolation percentage from frozen-thawed human cord blood is low and the future isolation percentage of MSCs from cryopreserved equine cord blood is therefore expectedly low...

  20. 77 FR 51783 - Federal Acquisition Regulation; Information Collection; Contractors' Purchasing Systems Reviews

    Science.gov (United States)

    2012-08-27

    ...; Information Collection; Contractors' Purchasing Systems Reviews AGENCY: Department of Defense (DOD), General... collection requirement concerning contractors' purchasing systems reviews. Public comments are particularly... Information Collection 9000- 0132, Contractors' Purchasing Systems Reviews, by any of the following methods...

  1. Virtual blood bank

    Directory of Open Access Journals (Sweden)

    Kit Fai Wong

    2011-01-01

    Full Text Available Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time.

  2. Miniaturized Blood Pressure Telemetry System with RFID Interface

    Directory of Open Access Journals (Sweden)

    Michele Caldara

    2016-08-01

    Full Text Available This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID tag, International Organization for Standardization (ISO 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure wave undergoes embedded processing and results are stored onboard in a non-volatile memory, providing the data under interrogation by an external RFID reader. In order to extend battery lifetime, RFID energy harvesting has been investigated. The paper presents the experimental characterization in a laboratory and preliminary in-vivo tests. The device is a prototype mainly intended, in a future engineered version, for monitoring freely moving test animals for pharmaceutical research and drug safety assessment purposes, but it could have multiple uses in environmental and industrial applications.

  3. Evaluation of an automated microplate technique in the Galileo system for ABO and Rh(D) blood grouping.

    Science.gov (United States)

    Xu, Weiyi; Wan, Feng; Lou, Yufeng; Jin, Jiali; Mao, Weilin

    2014-01-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated the Immucor Galileo System, a fully automated device based on the microplate hemagglutination technique for ABO/Rh (D) determinations. Routine ABO/Rh typing tests were performed on 13,045 samples using the Immucor automated instruments. Manual tube method was used to resolve ABO forward and reverse grouping discrepancies. D-negative test results were investigated and confirmed manually by the indirect antiglobulin test (IAT). The system rejected 70 tests for sample inadequacy. 87 samples were read as "No-type-determined" due to forward and reverse grouping discrepancies. 25 tests gave these results because of sample hemolysis. After further tests, we found 34 tests were caused by weakened RBC antibodies, 5 tests were attributable to weak A and/or B antigens, 4 tests were due to mixed-field reactions, and 8 tests had high titer cold agglutinin with blood qualifications which react only at temperatures below 34 degrees C. In the remaining 11 cases, irregular RBC antibodies were identified in 9 samples (seven anti-M and two anti-P) and two subgroups were identified in 2 samples (one A1 and one A2) by a reference laboratory. As for D typing, 2 weak D+ samples missed by automated systems gave negative results, but weak-positive reactions were observed in the IAT. The Immucor Galileo System is reliable and suited for ABO and D blood groups, some reasons may cause a discrepancy in ABO/D typing using a fully automated system. It is suggested that standardization of sample collection may improve the performance of the fully automated system.

  4. Implementation of good manufacturing practices (GMP) on human blood irradiation

    International Nuclear Information System (INIS)

    Boghi, Claudio; Napolitano, Celia M.; Ferreira, Danilo C.; Rela, Paulo Roberto; Zarate, Herman S.

    2007-01-01

    The irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease), a rare but devastating adverse effect of leukocytes present in blood components for a immuno-competent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of lymphocytes. The implementation of the GMP will assure that the properly dose in a range of 25 Gy to 50 Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies to establish the GMP were developed under the guidelines of the standard ISO 11137 - Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO 4 : Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, trace ability and calibration system. The PMMA and gafchromic dosimetric systems have shown a better performance and were adopted on establishment of GMP procedures. The irradiation tests have been done using a Gammacell 220 Irradiator. The developed GMP can be adapted for different types of gamma irradiators, allowing to set up a quality assurance program for blood irradiation. (author)

  5. Implementation of good manufacturing practices (GMP) on human blood irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Boghi, Claudio; Napolitano, Celia M.; Ferreira, Danilo C.; Rela, Paulo Roberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: cboghi@uol.com.br; cmnapoli@ipen.br; dancarde@ig.com.br; prela@ipen.br; Zarate, Herman S. [Comission Chilena de Energia Nuclear, Santiago (Chile)]. E-mail: hzarate@cchen.cl

    2007-07-01

    The irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease), a rare but devastating adverse effect of leukocytes present in blood components for a immuno-competent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of lymphocytes. The implementation of the GMP will assure that the properly dose in a range of 25 Gy to 50 Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies to establish the GMP were developed under the guidelines of the standard ISO 11137 - Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO{sub 4}: Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, trace ability and calibration system. The PMMA and gafchromic dosimetric systems have shown a better performance and were adopted on establishment of GMP procedures. The irradiation tests have been done using a Gammacell 220 Irradiator. The developed GMP can be adapted for different types of gamma irradiators, allowing to set up a quality assurance program for blood irradiation. (author)

  6. Good manufacturing practices (GMP utilized on human blood irradiation process

    Directory of Open Access Journals (Sweden)

    Cláudio Boghi

    2008-01-01

    Full Text Available Irradiation of human blood is used to avoid the TA-GVHD (transfusion-associated graft-versus-host-disease, a rare but devastating adverse effect of leukocytes present in blood components for immunocompetent transfusion recipients. Usually this irradiation practice is performed to a physical elimination of lymphocytes. The implementation of the GMP will assure that the properly dose in a range of 25Gy to 50Gy will be delivered to the blood in the bag collected in a blood tissue bank. The studies to establish the GMP were developed under the guidelines of the standard ISO 11137 - Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization. In this work, two dosimetric systems were used for dose mapping during the studies of irradiator qualification, loading pattern, irradiation process validation and auditing. The CaSO4: Dy dosimeter presented difficulties concerning to uncertainty on dose measurement, stability, trace ability and calibration system. The PMMA and gafchromic dosimetric systems have shown a better performance and were adopted on establishment of GMP procedures. The irradiation tests have been done using a Gammacell 220 Irradiator. The developed GMP can be adapted for different types of gamma irradiators, allowing to set up a quality assurance program for blood irradiation.

  7. What's Blood?

    Science.gov (United States)

    ... Body Make Blood? It's not made in a kitchen, but blood has ingredients, just like a recipe. ... these ingredients together and you have blood — an essential part of the circulatory system. Thanks to your ...

  8. Poor procedures and quality control among nonaffiliated blood centers in Burkina Faso: an argument for expanding the reach of the national blood transfusion center.

    Science.gov (United States)

    Nébié, Koumpingnin; Ouattara, Siaka; Sanou, Mahamoudou; Kientega, Youssouphe; Dahourou, Honorine; Ky, Lassina; Kienou, Kisito; Diallo, Samba; Bigirimana, Françoise; Fretz, Catherine; Murphy, Edward L; Lefrère, Jean-Jacques

    2011-07-01

    The World Health Organization (WHO) recommends the creation of national blood transfusion services. Burkina Faso has a CNTS (Centre National de Transfusion Sanguine-National Blood Transfusion Center) but it currently covers only 53% of the national blood supply versus 47% produced by independent hospital blood banks. To evaluate blood collection, testing, preparation, and prescription practices in the regions of Burkina Faso that are not covered by the CNTS, a cross-sectional survey was conducted. Data were collected by trained professionals from May to June 2009 at 42 autonomous blood centers not covered by the CNTS. Blood collection was supervised in all sites by laboratory technicians without specific training. There was no marketing of community blood donation nor mobile collection. Donation was restricted to replacement (family) donors in 21.4% of sites. Predonation screening of donors was performed in 63.4% of sites, but some did not use written questionnaires. Testing for HIV, hepatitis B virus, and syphilis was universal, although some sites did not screen for hepatitis C virus. In 83.3% of the sites, blood typing was performed without reverse ABO typing. In 97.6% of the sites, nurses acted alone or in conjunction with a physician to order blood transfusions. Shortcomings in non-CNTS blood centers argue for the development of a truly national CNTS. Such a national center should coordinate and supervise all blood transfusion activities, and is the essential first step for improving and institutionalizing blood transfusion safety and efficacy in a developing country. © 2011 American Association of Blood Banks.

  9. Pilot program for an automated data collection system

    International Nuclear Information System (INIS)

    Burns, R.S.; Johnson, P.S.; Denny, E.C.

    1984-01-01

    This report describes the pilot program of an automated data collection system and presents some of the managerial experiences during its startup. The pilot program demonstrated that improvements can be made in data collection and handling, even when a key hardware item does not meet requirements. 2 figures, 1 table

  10. [Blood donation in urban areas].

    Science.gov (United States)

    Charpentier, F

    2013-05-01

    Medical and technical developments increase the difficulty to provide sufficient safe blood for all patients in developed countries and their sociodemographic and societal changes. Sufficient national blood supply remains a reached, however still actual, challenge. Tomorrow is prepared today: the management of blood donation programs both in line with these developments and with social marketing strategies is one of the keys to success. If the main components of this organization are well known (mobile blood drives in various appropriate environments, and permanent blood donation centers) their proportions in the whole process must evolve and their contents require adaptations, especially for whole blood donation in urban areas. We have to focus on the people's way of life changes related to increasing urbanization of the society and prominent position taken by very large cities. This requires targeting several goals: to draw the attention of the potential blood-giving candidate, to get into position to collect him when he will decide it, to give meaning and recognition to his "sacrifice" (give time rather than donate blood) and to give him desire and opportunity to come back and donate one more time. In this strategy, permanent blood centers in urban areas have significant potential for whole blood collection, highlighted by the decrease of apheresis technology requirements. This potential requires profound changes in their location, conception and organization. The concept of Maison Du Don (MDD) reflects these changes. Copyright © 2013. Published by Elsevier SAS.

  11. Non-association between anti-Toxoplasma gondii antibodies and ABO blood group system

    Directory of Open Access Journals (Sweden)

    ACF Rodrigues

    2011-01-01

    Full Text Available Toxoplasma gondii infects humans through the gastrointestinal tract (GIT, which elicits humoral immune response with specific antibodies. The expression of the ABO blood group glycoconjugates also occurs in this same system and may influence the human susceptibility of infection by T. gondii. The aim of the present study was to investigate the association between ABO blood group phenotypes and the presence of anti-T. gondii antibodies. Data - including age, results of serology tests for T. gondii infection and ABO blood group phenotypes - were assembled from the medical records of 1,006 pregnant women attended in the Base Hospital of the Medical School of São José do Rio Preto, Brazil, between 2001 and 2004. The chi-square test was used to compare the results with the level of significance set at 5%. Of the studied cases, 64.1% (645/1006 and 35.9% (391/1006 presented respectively positive and negative serology tests for anti-T. gondii antibodies. The mean age of those who tested positive was higher than those with negative serology tests (p = 0.0004. The frequencies of ABO blood group phenotypes were similar in those with and without anti-T. gondii antibodies (p = 0.35. In conclusion, the ABO blood group system is not associated with the presence or absence of anti-T. gondii antibodies.

  12. Duffy blood group system and the malaria adaptation process in humans

    Directory of Open Access Journals (Sweden)

    Gledson Barbosa de Carvalho

    2011-02-01

    Full Text Available Malaria is an acute infectious disease caused by the protozoa of the genus Plasmodium. The antigens of the Duffy Blood Group System, in addition to incompatibilities in transfusions and hemolytic disease of the newborn, are of great interest in medicine due to their association with the invasion of red blood cells by the parasite Plasmodium vivax. For invasions to occur an interaction between the parasites and antigens of the Duffy Blood Group System is necessary. In Caucasians six antigens are produced by the Duffy locus (Fya, Fyb, F3, F4, F5 and F6. It has been observed that Fy(a-b- individuals are resistant to Plasmodium knowlesi and P. vivax infection, because the invasion requires at least one of these antigens. The P. vivax Duffy Binding Protein (PvDBP is functionally important in the invasion process of these parasites in Duffy / DARC positive humans. The proteins or fractions may be considered, therefore, an important and potential inoculum to be used in immunization against malaria.

  13. A study report of 174 units of placental umbilical cord whole blood transfusion in 62 patients as a rich source of fetal hemoglobin supply in different indications of blood transfusion.

    Science.gov (United States)

    Bhattacharya, N; Mukherijee, K; Chettri, M K; Banerjee, T; Mani, U; Bhattacharya, S

    2001-01-01

    In the animal kingdom, even herbivorous animals swallow the placenta after the birth of the baby (for example, the cow). In the human system, we do not know about the proper utilization of the placenta and membranes although there are suggestions regarding this on the basis of research on placental umbilical cord blood stem cells as an alternative to bone marrow transplantation. In this present series of placental umbilical cord whole blood transfusions, we wanted to examine the safety aspect of other components of cord blood transfusion, e.g., fetal RBC, growth factors and cytokine filled plasma, etc., in different indications of blood transfusion, from the pediatric to the geriatric age group, in malignant and non-malignant disorders affecting our patients. One hundred and seventy-four units of umbilical cord whole blood were collected aseptically from the umbilical vein after caesarean section in standard pediatric blood transfusion bags, after the removal of the baby from the operative field and after confirming the stable condition of the mother. The volume of cord blood varied from 50 ml to 140 ml with a mean of 86 ml+/-16 ml. The cord blood was transfused immediately (within three days of collection) to 62 patients from nine years to 78 years of age, of whom 32 were suffering from varying stages and grades of malignancy from 1 April 1999 till date i.e., 11 Aug 2000, after obtaining adequate consent and following the precautions of standard blood transfusion protocol. The remaining 30 patients included patients suffering from thalassemia major, aplastic anemia, systemic lupus erythematosus, chronic renal failure, rheumatoid arthritis, ankylosing spondylitis and a geriatric group of patients with benign prostatic hypertrophy. All have tolerated the procedure without any immunological or non-immunological reactions. On the basis of our experience with 174 units of placental umbilical cord whole blood transfusion in malignant and non-malignant conditions (within

  14. Enrichment of reticulocytes from whole blood using aqueous multiphase systems of polymers.

    Science.gov (United States)

    Kumar, Ashok A; Lim, Caeul; Moreno, Yovany; Mace, Charles R; Syed, Abeer; Van Tyne, Daria; Wirth, Dyann F; Duraisingh, Manoj T; Whitesides, George M

    2015-01-01

    This paper demonstrates the enrichment of reticulocytes by centrifuging whole blood through aqueous multiphase systems (AMPSs)-immiscible phases of solutions of polymers that form step-gradients in density. The interfaces of an AMPS concentrate cells; this concentration facilitates the extraction of blood enriched for reticulocytes. AMPS enrich reticulocytes from blood from both healthy and hemochromatosis donors. Varying the osmolality and density of the phases of AMPS provides different levels of enrichment and yield of reticulocytes. A maximum enrichment of reticulocytemia of 64 ± 3% was obtained from donors with hemochromatosis. When used on peripheral blood from normal donors, AMPS can provide a higher yield of enriched reticulocytes and a higher proportion of reticulocytes expressing CD71 than differential centrifugation followed by centrifugation over Percoll. Blood enriched for reticulocytes by AMPS could be useful for research on malaria. Several species of malaria parasites show a preference to invade young erythrocytes and reticulocytes; this preference complicates in vitro cultivation of these species in human blood. Plasmodium knowlesi malaria parasites invade normal human blood enriched for reticulocytes by AMPSs at a rate 2.2 times greater (P blood. Parasite invasion in normal blood enriched by AMPS was 1.8 times greater (P blood enriched to a similar reticulocytemia by differential centrifugation followed by centrifugation over Percoll. The enrichment of reticulocytes that are invaded by malaria parasites demonstrates that AMPSs can provide a label-free method to enrich cells for biological research. © 2014 Wiley Periodicals, Inc.

  15. Blood Test: Testosterone

    Science.gov (United States)

    ... Test: Estradiol Precocious Puberty Understanding Puberty Endocrine System Male Reproductive System Getting a Blood Test (Video) All About Puberty Blood Test (Video) Male Reproductive System View more About Us Contact Us Partners Editorial ...

  16. Mosquito blood-meal analysis for avian malaria study in wild bird communities: laboratory verification and application to Culex sasai (Diptera: Culicidae) collected in Tokyo, Japan.

    Science.gov (United States)

    Kim, Kyeong Soon; Tsuda, Yoshio; Sasaki, Toshinori; Kobayashi, Mutsuo; Hirota, Yoshikazu

    2009-10-01

    We conducted laboratory experiments to verify molecular techniques of avian malaria parasite detection distinguishing between an infected mosquito (oocysts on midgut wall) and infective mosquito (sporozoites in salivary glands) in parallel with blood-meal identification from individual blood-fed mosquitoes prior to application to field survey for avian malaria. Domestic fowl infected with Plasmodium gallinaceum was exposed to a vector and non-vector mosquito species, Aedes aegypti and Culex pipiens pallens, respectively, to compare the time course of polymerase chain reaction (PCR) detection for parasite between competent and refractory mosquitoes. DNA of the domestic fowl was detectable for at least 3 days after blood feeding. The PCR-based detection of P. gallinaceum from the abdomen and thorax of A. aegypti corresponded to the microscopic observation of oocysts and sporozoites. Therefore, this PCR-based method was considered useful as one of the criteria to assess developmental stages of Plasmodium spp. in mosquito species collected in the field. We applied the same PCR-based method to 21 blood-fed C. sasai mosquitoes collected in Rinshi-no-mori Park in urban Tokyo, Japan. Of 15 blood meals of C. sasai successfully identified, 86.7% were avian-derived, 13.3% were bovine-derived. Plasmodium DNA was amplified from the abdomen of three C. sasai specimens having an avian blood meal from the Great Tit (Parus major), Pale Thrush (Turdus pallidus), and Jungle Crow (Corvus macrorhynchos). This is the first field study on host-feeding habits of C. sasai in relation to the potential role as a vector for avian malaria parasites transmitted in the Japanese wild bird community.

  17. Blood Groups in the Kashmir Valley

    OpenAIRE

    Rafiq A.Calcutti, Mohammed Khali Lone, Showket Ahmed,Bashir A.Shah, Neelofer Jan.

    2003-01-01

    Blood groups are genetically determined and exJ1ibit polymorphism, where different populationgroups have significant difference in the frequency of each blood group. This study wasconducted to determine the frequency of ABO and Rhesus D blood groups among the blooddO:lors. A total number of 1306 blood donors attended the donor centre at SKIMS MedicalCollege Hospital for blood donation in the year 2001-02. After each donation blood sampleswere collected in separate pilot hlbes for the estimati...

  18. Transient spontaneous engraftment of CD34 hematopoietic cord blood stem cells as seen in peripheral blood: treatment of leprosy patients with anemia by placental umbilical cord whole blood transfusion.

    Science.gov (United States)

    Bhattacharya, N

    2006-01-01

    Cord blood, because of its rich mix of fetal and adult hemoglobin, high platelet and white blood cell (WBC) counts, and a plasma filled with cytokine and growth factors, as well as its hypoantigenic nature and altered metabolic profile, has all the potential of a real and safe alternative to adult blood transfusion. Our experience of 74 units (50 ml-146 ml mean, 86 ml +/- 7.6 ml SD, median 80 ml, mean packed cell volume 48 +/- 4.1 SD, mean percent hemoglobin concentration 16.2 g/dl +/- 1.8 g/dl of placental umbilical cord whole blood collection (from 1 April 1999) after lower uterine cesarean section (LUCS) from consenting mothers and transfusion of the same to 16 informed, consenting patients with percent plasma hemoglobin 8 g/dl or less, is presented here. After collection the blood was immediately preserved in the refrigerator and transfused within 72 hours of collection. Fifteen males and one female, aged 12-72 yrs (mean 48.4 yrs) participated: five cases were pausibacillary type (PB) and 11 cases were multibacillary type (MB). The clinical spectrum of the cases varied widely from the tuberculoid to the lepromatous type and one patient presented with gangrene of the leg preceding an auto amputation which was infested with maggots. Each case was approved by the institutional ethical committee and received two to eight units of freshly collected placental umbilical cord blood in one transfusion without encountering any clinical, immunological or non-immunological reaction. Seven days after completion of the placental umbilical cord blood transfusion, the peripheral blood hematopoietic stem cell (CD34) estimation revealed a rise from the pretransfusion base level (.09%), varying from 3.6% to 16.2%, in 75% of the cases, without provoking any clinical graft vs host reaction in any of the leprosy victims. This value returned to normal within three months in most cases.

  19. Transcriptome data of peripheral white blood cells from beef heifers collected at the time of artificial insemination

    Directory of Open Access Journals (Sweden)

    Sarah E. Dickinson

    2018-06-01

    Full Text Available The reproductive performance of heifers within their first breeding season influences the success of beef cattle operations. Therefore, a means to identify infertile and late breeding heifers before the start of the breeding season holds great promise for the future of the beef industry. Pubertal beef heifers were subjected to estrous synchronization and fixed time artificial insemination (FTAI. We collected peripheral blood from the heifers at the time of artificial insemination (AI and generated RNA sequencing data to characterize the transcriptome of peripheral white blood cells (PWBC. Following insemination, heifers were exposed to natural service for a defined breeding season, and pregnancy was evaluated to classify heifers into one of three groups: AI-pregnant, natural-bred (NB pregnant, and non-pregnant. The raw transcriptome data of PWBC is available on the NCBI GEO repository (GSE103628 where the reader can also find raw read counts and normalized gene expression data. The normalized data on transcript coverage can be visualized as a genome browser at HeiferFertilityRNAseq.org. Keywords: Biomarkers, Infertility, Pregnancy

  20. How do I provide leukapheresis products? Blood center experience and evidence for process improvement.

    Science.gov (United States)

    Ginzburg, Yelena; Kessler, Debra; Narici, Manlio; Caltabiano, Melinda; Rebosa, Mark; Strauss, Donna; Shaz, Beth

    2013-10-01

    The past few decades have seen a resurgence of interest in leukapheresis products to improve the survival of infected patients with neutropenia. These products have a short shelf life and require donor stimulation with dexamethasone before collection. Additionally, a system with good communications and logistical support is essential. A recent survey of blood centers in North America revealed that the majority of centers collecting leukapheresis products use steroid-stimulated donors. The survey results suggested that an analysis of the process and potential process improvement would be of interest to the transfusion medicine community. Data from 2008 to 2011 regarding donor selection, donor dexamethasone stimulation, leukapheresis collection, and correlations between potentially pertinent variables for process improvement were analyzed. Results from an analysis of cost are also included. We evaluate 432 leukapheresis donations and demonstrate correlations between 1) pre- and poststimulation white blood cell (WBC) count (pproduct granulocyte yield (pimprovement in granulocyte quality and yield can be accomplished in dexamethasone-stimulated donors, by selecting eligible donors with relatively high normal prestimulation WBC counts and/or previously good responses to dexamethasone, increasing the duration between dexamethasone stimulation and granulocyte collection, and maintaining optimal hematocrit (5%-10%) in granulocyte collections. Because the majority of surveyed blood centers collecting stimulated granulocytes use steroids alone, modifications presented here may prove useful. Further assessment of correlation between granulocyte yield and clinical outcome will await results of additional studies. © 2012 American Association of Blood Banks.

  1. Role of Tranexamic Acid in Reducing Blood Loss in Vaginal Delivery.

    Science.gov (United States)

    Roy, Priyankur; Sujatha, M S; Bhandiwad, Ambarisha; Biswas, Bivas

    2016-10-01

    Anti-fibrinolytic agents are used to reduce obstetric blood loss as the fibrinolytic system is known to get activated after placental delivery. To evaluate the efficacy of parenteral tranexamic acid in reducing blood loss during normal labour and to compare it with the amount of blood loss in patients who received placebo in the third stage of labour. Patients with spontaneous labour or planned for induction of labour and fulfilling the inclusion criteria were recruited for the study. In each patient, the pre-delivery pulse rate, blood pressure, Hb gm% and PCV% were noted. Labour was monitored carefully using a partogram. The study group received Inj. Oxytocin and Inj. Tranexamic acid. The control group received Inj. Oxytocin and Placebo injection. Immediately after delivery of the baby, when all the liquor was drained, the patient was placed over a blood drape-a disposable conical, graduated plastic collection bag. The amount of blood collected in the blood drape was measured. Then the patient was given pre-weighed pads, which were weighed 2 h post-partum. The blood loss was measured by measuring the blood collected in the drape and by weighing the swabs before and after delivery. The total number of patients studied was 100-equally distributed in both the groups. The age group of the patients and BMI were comparable. There was a significant increase in the pulse rate and decrease in blood pressure in the control group as compared with the study group. The post-delivery haemoglobin and haematocrit were significantly reduced in the control group as compared to the study group. The mean blood loss at the end of 2 h was 105 ml in the study group and 252 ml in the control group. There was a significant increase in the usage of uterotonics and also in the need for blood transfusion in the control group; 12 % of the patients in the control group had to stay for more than 3 days compared to 2 % in the study group. Tranexamic acid injection, an antifibrinolytic

  2. The state of glutathion system of blood, brain and liver of white rats after chronic gamma-irradiation

    International Nuclear Information System (INIS)

    Petushok, N.Eh.; Lashak, L.K.; Trebukhina, R.V.

    1999-01-01

    The effects of 3-fold gamma-irradiation in total dose 0,75 Gy on the glutathion system in different periods after exposure (1 hour, 1 day, 1 and 4 weeks) in blood, brain and liver of white rats were studied. It was concluded that liver and brain have higher ability to maintain the stability of antioxidant system than blood has. After shot disturbances caused by irradiation in brain and liver the state of glutathion system of detoxication has normalized, while concentration of malonic dialdehyde was raised in all terms. The most pronounced changes of antioxidant system were registered in blood at early terms (1 hour) after irradiation that was manifested in increasing of reduced glutathion content, raising of glutathion reductase and catalase activity. In remote period the activity of this system in blood was exhausted

  3. Plant operation data collection and database management using NIC system

    International Nuclear Information System (INIS)

    Inase, S.

    1990-01-01

    The Nuclear Information Center (NIC), a division of the Central Research Institute of Electric Power Industry, collects nuclear power plant operation and maintenance information both in Japan and abroad and transmits the information to all domestic utilities so that it can be effectively utilized for safe plant operation and reliability enhancement. The collected information is entered into the database system after being key-worded by NIC. The database system, Nuclear Information database/Communication System (NICS), has been developed by NIC for storage and management of collected information. Objectives of keywords are retrieval and classification by the keyword categories

  4. Towards a Hyperconnected Transportation Management System: Application to Blood Logistics

    OpenAIRE

    Schoen , Quentin; Lauras , Matthieu; Truptil , Sébastien; Fontanili , Franck; Anquetil , Anne-Ghislaine

    2016-01-01

    Part 1: Hyperconnectivity and Interoperation - Hyperconnected Systems; International audience; Internet of Things, connected devices, and other wireless sensors networks offer a number of new opportunities to manage transportation flows. This is particularly interesting for critical Supply Chains like Blood Supply Chains. In this research work, we investigate how such new technologies can enhance transportation system by better managing hazards and changes. By developing an event-driven decis...

  5. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    Science.gov (United States)

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Bluetooth data collection system for planning and arterial management.

    Science.gov (United States)

    2014-08-01

    This report presents the results of a research and development project of an implementable portable wireless traffic data collection system. Utilizing Bluetooth wireless technology as a platform, portable battery powered data collection units housed ...

  7. The Welsh Blood Service - 70 years of continuous change.

    Science.gov (United States)

    Poole, G D

    2017-06-01

    would become ever more important, although the impact of this was lessened somewhat by a decreasing demand for blood following the Better Blood Transfusion initiatives. The Medicines and Healthcare Products Regulatory Agency found new powers and impetus after the so-called EU Blood Directive was transposed into British law, and the inspection regime became significantly more onerous, requiring more resources to be put in this area. A strategic review found that some parts of the service required extensive modernisation, such as the information technology system in use and the deployment of staff on the blood collection teams, and these matters were attended to. The review also prompted the Welsh Government to consider the question of blood supply to and blood collection in North Wales, which had been the remit of the Liverpool Centre since the establishment of the NBTS in 1946. The Welsh Government duly announced the creation of an all-Wales Blood Service, and finally, in May 2016, 70 years after its creation, the WBS took over responsibility for blood collection and blood provision in the whole of Wales. © 2017 British Blood Transfusion Society.

  8. Step-by-Step robotic heminephrectomy for duplicated renal collecting system

    Directory of Open Access Journals (Sweden)

    Homayoun Zargar

    2014-08-01

    Full Text Available Introduction A duplicated renal collecting system is a relatively common congenital anomaly rarely presenting in adults. Aim In this video we demonstrate our step-by-step technique of Robotic heminephrectomy in a patient with non-functioning upper pole moiety. Materials and Methods Following cystoscopy and ureteral catheter insertion the patient was placed in 600 modified flank position with the ipsilateral arm positioned at the side of the patient. A straight-line, three arm robotic port configuration was employed. The robot was docked at a 90-degree angle, perpendicular to the patient. Following mobilization the colon and identifying both ureters of the duplicated system, the ureters were followed cephalically toward, hilar vessels where the hilar anatomy was identified. The nonfunctioning pole vasculature was ligated using hem-o-lok clips. The ureter was sharply divided and the proximal ureteral stump was passed posterior the renal hilum. Ureteral stump was used as for retraction and heminephrectomy is completed along the line demarcating the upper and lower pole moieties. Renorrhaphy was performed using 0-Vicryl suture with a CT-1 needle. The nonfunctioning pole ureter was then dissected caudally toward the bladder hiatus, ligated using clips, and transected. Results The operating time was 240 minutes and blood loss was 100 cc. There was no complication post-operatively. Conclusions Wrist articulation and degree of freedom offered by robotic platform facilitates successful performance of minimally invasive heminephrectomy in the setting of an atrophic and symptomatic renal segment.

  9. The pattern of blood donation and transfusion transmissible ...

    African Journals Online (AJOL)

    Background: Blood for transfusion in Nigeria is largely collected from family members or commercial blood donors who would rather conceal information that could disqualify them from blood donation. The blood service is expected to transform blood sources to voluntary, guided by altruism and self-risk assessment and ...

  10. FREQUENCY OF ABO AND RHESUS (D) BLOOD GROUPS IN TRIBAL P OPULATION OF MADHYA PRADESH: A STUDY FROM TERTIARY CARE TEACHING HOSPITAL IN MADHYA PRADESH

    OpenAIRE

    Ajit; Dolly

    2015-01-01

    BACKGROUND: ABO and Rh blood groups are most important blood groups in human beings. The frequency of four main blood group systems varies in population throughout the world and even in different parts of country. Objective if this study was to identify distribution o f ABO and Rh blood group system. MATERIALS AND METHODS: Blood samples from 10680 tribals were collected in Jhabua district of Madhya Pradesh during the month of June 2012. Among 10680 tribals, 5670 wer...

  11. Smart City Platform Development for an Automated Waste Collection System

    Directory of Open Access Journals (Sweden)

    Cicerone Laurentiu Popa

    2017-11-01

    Full Text Available Nowadays, governments and companies are looking for solutions to increase the collection level of various waste types by using new technologies and devices such as smart sensors, Internet of Things (IoT, cloud platforms etc. In order to fulfil this need, this paper presents solutions provided by a research project involving the design, development and implementation of fully automated waste collection systems with an increased usage degree, productivity and storage capacity. The paper will focus on the main results of this research project in turning the automated waste collection system into a smart system so that it can be easily integrated in any smart city infrastructure. For this purpose, the Internet of Things platform for the automated waste collection system provided by the project will allow real time monitoring and communication with central systems. Details about each module are sent to the central systems: various modules’ statuses (working, blocked, needs repairs or maintenance etc.; equipment status; storage systems status (allowing full reports for all waste types; the amount of waste for each module, allowing optimal discharging; route optimization for waste discharging etc. To do that, we describe here an IoT cloud solution integrating device connection, data processing, analytics and management.

  12. Molecular versus particulate deposition markers for blood flow measurement in the musculo-skeletal system. 131Iodo-DesMethyl-Imipramine

    International Nuclear Information System (INIS)

    Tromborg, H.B.

    1998-01-01

    The aims of the experiments were to develop and validate a porcine isolated blood perfused myocutaneous flap and tibia model with preserved venous outflow. The stability of the models was tested and washout of microspheres and IDMI was measured. IDMI and microsphere based tissue blood flow measurements were compared after central intracardiac injection into the intact animal. Three experimental series were necessary to develop and validate the models. The organs were perfused with arterial blood by a pulsatile pump and submerged into a tissue bath. All outflow from the models were collected. One experiment was necessary to validate the rectus abdominis myocutaneous flap. In three experiments an isolated tibia with preserved venous outflow was developed and validated. Normal flow rate/perfusion pressure relations were reproduced after periods of supra-normal and sub-normal perfusion pressure in the two models. A response to endothelially mediated vasodilation with bradykinin was demonstrated after nine hours of artificial perfusion in the tibia model. IDMI did not influence the local hemodynamics during infusion, whereas microspheres elicited a transitory increase in the perfusion pressure after local injection. IDMI and microsphere based blood flow measurements and recirculation were compared in the in-situ musculo-skeletal tissue corresponding to the two models after central injection of the markers. Recirculation of IDMI was greater (8(1)%) than that of microspheres (2(0)%) after 18 minutes. Microspheres tended to measure higher blood flow values than IDMI at high flow rates and vice versa at low flow values. The 131 Iodo-DesMethyl-Imipramine (IDMI) method is not generally applicable as a deposition marker for blood flow measurement in the musculo-skeletal system. (EHS)

  13. High-speed and high-fidelity system and method for collecting network traffic

    Science.gov (United States)

    Weigle, Eric H [Los Alamos, NM

    2010-08-24

    A system is provided for the high-speed and high-fidelity collection of network traffic. The system can collect traffic at gigabit-per-second (Gbps) speeds, scale to terabit-per-second (Tbps) speeds, and support additional functions such as real-time network intrusion detection. The present system uses a dedicated operating system for traffic collection to maximize efficiency, scalability, and performance. A scalable infrastructure and apparatus for the present system is provided by splitting the work performed on one host onto multiple hosts. The present system simultaneously addresses the issues of scalability, performance, cost, and adaptability with respect to network monitoring, collection, and other network tasks. In addition to high-speed and high-fidelity network collection, the present system provides a flexible infrastructure to perform virtually any function at high speeds such as real-time network intrusion detection and wide-area network emulation for research purposes.

  14. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  15. Distribution of blood groups in blood donors in the blood bank of Jagdalpur, Bastar district, Chhattisgarh

    Directory of Open Access Journals (Sweden)

    Sachin A Badge

    2017-01-01

    Full Text Available Aims and Objectives: The incidence of ABO and rhesus (Rh groups varies markedly in different races, ethnic groups, and socioeconomic groups in different parts of the world. The frequencies of ABO and Rh blood groups vary from one population to another and time to time in the same region. The present study was carried out to find the distribution of blood group in rural and tribal populations of Bastar district of Chhattisgarh. Materials and Methods: The present retrospective study was carried out at late Shri Baliram Kashyap Memorial Government Medical College and Maharani Hospital blood bank, Jagdalpur, Bastar district, Chhattisgarh, India, during the 2-year period from January 2014 to December 2015. The blood collections were taken from the voluntary donors at outdoor blood donation camp and in-house blood bank as well as from replacement donors at blood bank. Totally 12,852 donors were considered medically fit and accepted for blood donation during the study period. Results: Out of the total 12,852 donors, most of the donors, i.e., 3996 (31.09% were with blood Group O followed by B (30.44%, A (24.95%, and AB (13.52%. Out of the 12,852 blood donors, majority, i.e., 12,779 (99.43% were male and 73 (0.57% were female. Maximum blood donors, i.e., 12,777 (99.42% were Rh positive while only 75 (0.58% were Rh negative. Conclusion: The knowledge of distribution of ABO and Rh blood groups at local and regional levels is helpful in effective management of blood banks and safe blood transfusion services.

  16. MAC, A System for Automatically IPR Identification, Collection and Distribution

    Science.gov (United States)

    Serrão, Carlos

    Controlling Intellectual Property Rights (IPR) in the Digital World is a very hard challenge. The facility to create multiple bit-by-bit identical copies from original IPR works creates the opportunities for digital piracy. One of the most affected industries by this fact is the Music Industry. The Music Industry has supported huge losses during the last few years due to this fact. Moreover, this fact is also affecting the way that music rights collecting and distributing societies are operating to assure a correct music IPR identification, collection and distribution. In this article a system for automating this IPR identification, collection and distribution is presented and described. This system makes usage of advanced automatic audio identification system based on audio fingerprinting technology. This paper will present the details of the system and present a use-case scenario where this system is being used.

  17. 78 FR 33846 - Agency Information Collection Activities; Proposed Collection; Comment Request; Biological...

    Science.gov (United States)

    2013-06-05

    ..., and Forms FDA 3486 and 3486A. DATES: Submit electronic or written comments on the collection of information by August 5, 2013. ADDRESSES: Submit electronic comments on the collection of information to: http... Source Plasma, unlicensed registered blood establishments, and transfusion services, who had control over...

  18. Donor Hemovigilance Programme in managing Blood Transfusion Needs: Complications of Whole Blood Donation

    Directory of Open Access Journals (Sweden)

    S Mangwana

    2013-10-01

    Full Text Available Background: Hemovigilance like quality systems and audits have become an integral part of Blood Transfusion Services in the developed countries and has contributed greatly to its development. Hemovigilance begins with donors and must enable the collection of information on reactions occurring during the donation of blood, selections of donors and to prevent such incidents. The aim of study was to help identify the trends of adverse events , occurring in blood donors at a tertiary-care hospital, to recommend best practices to improve donor care and safety Materials and Methods: This record-based study was conducted on all adverse events related to allogenic whole blood donations performed over 24 months. All whole blood donations were analyzed. All adverse events occurring during or at the end of the donation were noted using a standardized format and analyzed determining significance at p<0.05. Results: Overall rate was 0.3% with vasovagal reactions constituting 82%, and 18% mild syncopal reactions (p<0.001. Immediate vasovagal reaction with injury was very rare (0.007%. Vasovagal reactions showed a significant association with young age, female gender, first time donation status. Mean age of persons recording adverse effects was 30.23 ± 7.49 years as compared to those without adverse effects, 31.14 ± 8.56 years. Conclusion: Donor safety is an essential perquisite to increase voluntary blood donation. AE analysis helps in identifying the blood donors at risk of AE, applying appropriate motivational strategies, predonation counseling, care during and after donation, developing guidelines and hemovigilance programme in countries with limited resources. DOI: http://dx.doi.org/10.3126/jpn.v3i6.8993   Journal of Pathology of Nepal (2013 Vol. 3, 459-463

  19. Influence of ionizing radiation and 12-crown-4 on coagulation system components of rat blood

    International Nuclear Information System (INIS)

    Kratenko, R.Yi.

    2006-01-01

    The influence of 12-crown-4 and ionizing radiation on some components of blood coagulation system: Ca 2+ contents and prostaglandin concentrations in the blood serum, and erythrocyte contents in the blood plasma are studied. The influence of 12-crown-4 and ionizing radiation increases the coagulational properties of erythrocytes. The synergism of ionizing irradiation and 12-crown-4 influence blood coagulation process points out at the occurrence of radiomimetic properties of the latter

  20. New method for rapid Susceptibility Testing on blood culture with HB&L system: preliminary data

    Directory of Open Access Journals (Sweden)

    Vincenzo Rondinelli

    2010-12-01

    Full Text Available Blood culture, although represents the gold standard in detecting the ethiological agent of sepsis, is rather rarely required in relation to the real diagnostic importance. The result of this test depends in fact on many factors (sample volume, time of collection, accuracy, antibiotic therapy, contamination, number of drawings, drawing site, interpretation difficulties, etc. that are often considered by many clinicians so limited as to doubt about their actual value. The disadvantages are therefore represented by the lack of standardization but also by the low sensitivity and above all by the technical times too long for the clinical needs. Blood culture begins with the drawing of samples from the “septic” patient followed incubation of the bottles in automatic thermostated systems. In case of positive result (36 hours, the culture is Gram stained and streaked on solid media in order to obtain isolated colonies for the identification and the susceptibility testing (48 hours from positive result. The long time required for pathogen identification and susceptibility testing involves empirical broad spectrum antibiotic therapy that can promote the increase of bacterial resistance but also patient management costs. A clinically useful report should be available on short notice in order to guide the clinician to choose the most appropriate antibiotic. The microbiologist has therefore the hard work of reviewing the organization and the management of the procedures.We have therefore started to consider the possibility of treating the blood as an biological liquid in order to quickly determine the susceptibility of bacteria to antibiotics.

  1. Blood lead levels among rural Thai children exposed to lead-acid batteries from solar energy conversion systems.

    Science.gov (United States)

    Swaddiwudhipong, Witaya; Tontiwattanasap, Worawit; Khunyotying, Wanlee; Sanreun, Cherd

    2013-11-01

    We evaluate blood lead levels among Thai children to determine if exposure to lead-acid batteries is associated with elevated blood lead levels (EBLL). We screened 254 children aged 1-14 years old from 2 rural Thai villages for blood lead levels. We also screened 18 of 92 houses in these 2 villages for the presence of environmental lead. The overall prevalence of EBLL (> or = 10 microg/dl) was 43.3% and the mean lead level among study subjects was 9.8 +/- 5.1 microg/dl. The blood lead levels significantly decreased with increasing age. Fifty point eight percent of children who lived in a house with vented lead-acid batteries had EBLL while 23.3% of children who lived in a house without vented lead-acid batteries had EBLL. Multiple logistic regression analysis revealed a significant positive association between the presence of vented lead-acid batteries and EBLL, after adjusting for other variables. Forty-two point nine percent of house floor dust samples collected near the batteries had elevated lead levels, 7.1% of house floor dust samples collected from other areas in the house had elevated lead levels and 0% of the house floor dust samples collected in houses without vented lead-acid batteries had elevated lead levels. In the sampled houses with vented lead-acid batteries, lead contamination was found in the drinking-water kept in household containers, but not in the tap water or other village sources of water. Improper care and placement of vented lead-acid batteries can result in lead contamination in the home environment causing EBLL in exposed children.

  2. Multicenter Clinical Evaluation of BacT/Alert Virtuo Blood Culture System.

    Science.gov (United States)

    Jacobs, Michael R; Mazzulli, Tony; Hazen, Kevin C; Good, Caryn E; Abdelhamed, Ayman M; Lo, Pauline; Shum, Bianche; Roman, Katharine P; Robinson, Danielle C

    2017-08-01

    BacT/Alert Virtuo is an advanced, automated blood culture system incorporating improved automation and an enhanced detection algorithm to shorten time to detection. A multicenter study of the investigational Virtuo system (bioMérieux, Inc., Durham, NC) compared to BacT/Alert 3D (BTA3D) for detection of bacteremia/fungemia in four bottle types, SA and FA Plus (aerobic) and SN and FN Plus (anaerobic), was performed in a clinical setting with patient samples in a matched system design clinical trial. Blood was added to paired aerobic or anaerobic bottles, with the volume in each bottle in each pair required to be ≤10 ml and with the volumes required to be within 30% of each other. Of 5,709 bottle sets (52.5% aerobic pairs and 47.5% anaerobic pairs), 430 (7.5%) were positive for bacterial or fungal growth, with 342 (6.0%) clinically significant and 83 (1.5%) contaminated. A total of 3,539 sets (62.0%) were volume compliant, with 203 sets (5.7%) clinically significant. The positivity rates for volume-compliant bottle pairs determined by the two systems were comparable, with 68.7% of clinically significant isolates detected by both instruments, 15.7% by Virtuo only, and 15.7% by BTA3D only. Virtuo detected microbial growth nearly 2 h sooner overall than BTA3D (mean, 15.9 h versus 17.7 h). Shorter time to detection by Virtuo was related to organism group, with the time to detection being significantly shorter for enteric Gram-negative bacilli and enterococci (means, 3.6 h and 2.3 h shorter, respectively). This large clinical study demonstrated that the Virtuo blood culture system produced results comparable to those seen with the long-established BTA3D system, with significantly shorter time to detection. Copyright © 2017 Jacobs et al.

  3. Modular sludge collection system for a nuclear steam generator

    International Nuclear Information System (INIS)

    Appleman, R.H.; Bein, J.D.; Powasaki, F.S.

    1986-01-01

    A sludge collection system is described for a vertically oriented nuclear steam generator wherein vapors produced in the steam generator pass through means for separating entrained liquid from the vapor prior to the vapor being discharged from the steam generator. The sludge collection system comprises: an upwardly open chamber for collecting the separated liquid and feedwater entering the steam generator; upwardly open sludge collecting containers positioned within the chamber, wherein each of the containers includes a top rim encompassing an opening leading to the interior of each container; generally flat, perforated covers, each of the covers being positioned over one of the openings such that a gap is formed between the cover and the adjacent top rim; sludge agitating means on at least one of the containers; and sludge removal means on at least one of the containers

  4. Autologous blood transfusion in total knee replacement surgery.

    Science.gov (United States)

    Sarkanović, Mirka Lukić; Gvozdenović, Ljiljana; Savić, Dragan; Ilić, Miroslav P; Jovanović, Gordana

    2013-03-01

    Total knee replacement (TKR) surgery is one of the most frequent and the most extensive procedures in orthopedic surgery, accompanied with some serious complications. Perioperative blood loss is one of the most serious losses, so it is vital to recognize and treat such losses properly. Autologous blood transfusion is the only true alternative for the allogeneic blood. The aim of this study was to to examine if autologous blood transfusion reduces usage of allogenic blood in total knee replacement surgery, as well as to examine possible effect of autologous blood transfusion on postoperative complications, recovery and hospital stay of patients after total knee replacement surgery. During the controlled, prospective, randomised study we compared two groups of patients (n = 112) with total prosthesis implanted in their knee. The group I consisted of the patients who received the transfusion of other people's (allogeneic) blood (n = 57) and the group II of the patients whose blood was collected postoperatively and then given them [their own (autologous) blood] (n = 55). The transfusion trigger for both groups was hemoglobin level of 85 g/L. In the group of patients whose blood was collected perioperatively only 9 (0.9%) of the patients received transfusion of allogeneic blood, as opposed to the control group in which 98.24% of the patients received the transfusion of allogeneic blood (p blood was collected stayed in hospital for 6.18 days, while the patients of the control group stayed 7.67 days (p blood transfusion is a very effective method for reducing consumption of allogenic blood and thus, indirectly for reducing all complications related to allogenic blood transfusion. There is also a positive influence on postoperative recovery after total knee replacement surgery due to the reduction of hospital stay, and indirectly on the reduction of hospital costs.

  5. Poor procedures and quality control among non-affiliated blood centers in Burkina Faso: an argument for expanding the reach of the national blood transfusion center

    Science.gov (United States)

    Nébié, Koumpingnin; Ouattara, Siaka; Sanou, Mahamoudou; Kientega, Youssouphe; Dahourou, Honorine; Ky, Lassina; Kienou, Kisito; Diallo, Samba; Bigirimana, Françoise; Fretz, Catherine; Murphy, Edward L.; Lefrère, Jean-Jacques

    2011-01-01

    Introduction The World Health Organization (WHO) recommends the creation of national blood transfusion services. Burkina Faso has a CNTS (Centre national de transfusion sanguine - National Blood Transfusion Center) but it currently covers only 53% of the national blood supply versus 47% produced by independent hospital blood banks. Study design To evaluate blood collection, testing, preparation and prescription practices in the regions of Burkina Faso that are not covered by the CNTS, we conducted a cross-sectional survey. Methodology Data were collected by trained professionals from May to June 2009, at 42 autonomous blood centers not covered by the CNTS. Results Blood collection was supervised in all sites by laboratory technicians without specific training. There was no marketing of community blood donation nor mobile collection. Donation was restricted to replacement (family) donors in 21.4% of sites. Pre-donation screening of donors was performed in 63.4% of sites, but some did not use written questionnaires. Testing for HIV, hepatitis B virus and syphilis was universal, although some sites did not screen for hepatitis C virus. In 83.3% of the sites blood typing was performed without reverse ABO typing. In 97.6% of the sites, nurses acted alone or in conjunction with a physician to order blood transfusions. Conclusion Shortcomings in non-CNTS blood centers argue for the development of a truly national CNTS. Such a national center should coordinate and supervise all blood transfusion activities, and is the essential first step for improving and institutionalizing blood transfusion safety and efficacy in a developing country. PMID:21736582

  6. Effects of Clove Oil as a Euthanasia Agent on Blood Collection Efficiency and Serum Cortisol Levels in Danio rerio

    OpenAIRE

    Davis, Daniel J; Klug, Jenna; Hankins, Miriam; Doerr, Holly M; Monticelli, Stephanie R; Song, Ava; Gillespie, Catherine H; Bryda, Elizabeth C

    2015-01-01

    Zebrafish are an important laboratory animal model for biomedical research and are increasingly being used for behavioral neuroscience. Tricaine methanesulfonate (MS222) is the standard agent used for euthanasia of zebrafish. However, recent studies of zebrafish behavior suggest that MS222 may be aversive, and clove oil might be a possible alternative. In this study, we compared the effects of MS222 or clove oil as a euthanasia agent in zebrafish on the volume of blood collected and on serum ...

  7. MRI of subdural fluid collections in infants

    International Nuclear Information System (INIS)

    Fukushima, Tsuneyuki; Takagi, Takuji; Nagai, Hajime; Banno, Tatsuo

    1988-01-01

    Twenty cases of subdural fluid collectioin in infants were examined by MRI (0.5 Tesla). The findings of MRI were classified into 3 groups as follows: Group I: Blood component is observed in the entire subdural fluid (4 cases, 20 %). Group II: Blood component is observed in a part of the subdural fluid (4 cases, 20 %). Group III: Subdural fluid consists of pure CSF (12 cases, 60 %). In general, operative treatment should be considered for cases which have blood components in the subdural space and/or symptoms and signs of increased ICP. In group I, operation was performed on 2 cases (50 %). In group II, subdural fluid collections were associated with dilated subarachnoid spaces and 2 cases were operated on in this group (50 %). In group III, only one case was operated on (8.3 %) and subdural fluid collections disappeared spontaneously in 4 cases of this group. The precise anatomical location of subdural fluid collections could not be decided in several cases even by MRI. The cases which had blood components, tended to demonstrate membranes frequently on MRI. However, the existence of blood components did not affect the DQ S significantly. The prognosis of subdural fluid collection is supposedly related to the degree of preexistent brain damage. (author)

  8. Performance and safety of femoral central venous catheters in pediatric autologous peripheral blood stem cell collection.

    Science.gov (United States)

    Cooling, Laura; Hoffmann, Sandra; Webb, Dawn; Yamada, Chisa; Davenport, Robertson; Choi, Sung Won

    2017-12-01

    Autologous peripheral blood hematopoietic progenitor cell collection (A-HPCC) in children typically requires placement of a central venous catheter (CVC) for venous access. There is scant published data regarding the performance and safety of femoral CVCs in pediatric A-HPCC. Seven-year, retrospective study of A-HPCC in pediatric patients collected between 2009 and January 2017. Inclusion criteria were an age ≤ 21 years and A-HPCC using a femoral CVC for venous access. Femoral CVC performance was examined by CD34 collection rate, inlet rate, collection efficiency (MNC-FE, CD34-FE), bleeding, flow-related adverse events (AE), CVC removal, and product sterility testing. Statistical analysis and graphing were performed with commercial software. A total of 75/119 (63%) pediatric patients (median age 3 years) met study criteria. Only 16% of children required a CVC for ≥ 3 days. The CD34 collect rate and CD34-FE was stable over time whereas MNC-FE decreased after day 4 in 80% of patients. CD34-FE and MNC-FE showed inter- and intra-patient variability over time and appeared sensitive to plerixafor administration. Femoral CVC showed fewer flow-related AE compared to thoracic CVC, especially in pediatric patients (6.7% vs. 37%, P = 0.0005; OR = 0.12 (95%CI: 0.03-0.45). CVC removal was uneventful in 73/75 (97%) patients with hemostasis achieved after 20-30 min of pressure. In a 10-year period, there were no instances of product contamination associated with femoral CVC colonization. Femoral CVC are safe and effective for A-HPCC in young pediatric patients. Femoral CVC performance was maintained over several days with few flow-related alarms when compared to thoracic CVCs. © 2017 Wiley Periodicals, Inc.

  9. HB&L System: rapid determination of antibiotic sensitivity of bacteria isolated from blood cultures.

    Directory of Open Access Journals (Sweden)

    Simone Barocci

    2010-03-01

    Full Text Available Introduction. Blood culture is an important method to detect microbial pathogens on blood, very useful for diagnosing bacterial infections. Unfortunately, classical diagnostic protocols cannot directly identify bacteria responsible for sepsis and accordingly their antimicrobial profiles. This problem causes a delay of almost two days in the availability of a specific antimicrobial profile. Objective. Among the main causes of death, sepsis have a relevant importance. For this reason it is important both to identify pathogens and to perform an antimicrobial susceptibility test in the shortest time as possible. For this purpose, the main aim of this study is the evaluation of the performances of an antimicrobial susceptibility determination directly performed on positive blood cultures. Materials and methods. This study has been performed on 70 positive blood cultures, during the period from January to July 2009. A number of 35 blood cultures were positive for Gram negative bacteria, and 35 were positive for Gram positive bacteria. From these positive blood cultures, after a short sample preparation, it has been possible to directly determine antimicrobial susceptibility profiles by using the HB&L (formerly URO-QUICK instrument. Results. The HB&L system results showed a very good correlation with both the classical disk diffusion method and VITEK 2 automatic system.The performances between the methods carried out in this study were equivalent. Conclusions. From data reported, thanks to the rapidity and simplicity of the method used, we can assert that the direct susceptibility test available with the HB&L system, is useful for a rapid and early choice of the antibiotic treatment.

  10. Virtual model of an automated system for the storage of collected waste

    Directory of Open Access Journals (Sweden)

    Enciu George

    2017-01-01

    Full Text Available One of the problems identified in waste collection integrated systems is the storage space. The design process of an automated system for the storage of collected waste includes finding solutions for the optimal exploitation of the limited storage space, seen that the equipment for the loading, identification, transport and transfer of the waste covers most of the available space inside the integrated collection system. In the present paper a three-dimensional model of an automated storage system designed by the authors for a business partner is presented. The storage system can be used for the following types of waste: plastic and glass recipients, aluminium cans, paper, cardboard and WEEE (waste electrical and electronic equipment. Special attention has been given to the transfer subsystem, specific for the storage system, which should be able to transfer different types and shapes of waste. The described virtual model of the automated system for the storage of collected waste will be part of the virtual model of the entire integrated waste collection system as requested by the beneficiary.

  11. Association of ABO and Rh Blood Groups to Blood-Borne Infections among Blood Donors in Tehran-Iran.

    Science.gov (United States)

    Mohammadali, Fatemeh; Pourfathollah, Aliakbar

    2014-07-01

    The aim of this study was to investigate the prevalence of hepatitis B, hepatitis C, HIV and syphilis infections in blood donors referred to Tehran Blood Transfusion Center (TBTC), and determine any association between blood groups and blood- borne infections between the years of 2005 and 2011. This was a retrospective study conducted at TBTC. All of the donor serum samples were screened for HBV, HCV, HIV and syphilis by using third generation ELISA kits and RPR test. Initial reactive samples were tested in duplicate. Confirmatory tests were performed on all repeatedly reactive donations. Blood group was determined by forward and reverse blood grouping. The results were subjected to chi square analysis for determination of statistical difference between the values among different categories according to SPSS program. Overall, 2031451 donor serum samples were collected in 2005-2011. Totally, 10451 were positive test for HBV, HCV, HIV and syphilis. The overall seroprevalence of HBV, HCV, HIV, and syphilis was 0.39%, 0.11%, 0.005%, and 0.010%, respectively. Hepatitis B and HIV infections were significantly associated with blood group of donors (P blood group "A" and percentage of HBs Ag was lower in donors who had blood group O. There was no significant association between Hepatitis C and syphilis infections with ABO and Rh blood groups (P>0.05). Compared with neighboring countries and the international standards, prevalence of blood-borne infections is relatively low.

  12. Collision Based Blood Cell Distribution of the Blood Flow

    Science.gov (United States)

    Cinar, Yildirim

    2003-11-01

    Introduction: The goal of the study is the determination of the energy transferring process between colliding masses and the application of the results to the distribution of the cell, velocity and kinetic energy in arterial blood flow. Methods: Mathematical methods and models were used to explain the collision between two moving systems, and the distribution of linear momentum, rectilinear velocity, and kinetic energy in a collision. Results: According to decrease of mass of the second system, the velocity and momentum of constant mass of the first system are decreased, and linearly decreasing mass of the second system captures a larger amount of the kinetic energy and the rectilinear velocity of the collision system on a logarithmic scale. Discussion: The cause of concentration of blood cells at the center of blood flow an artery is not explained by Bernoulli principle alone but the kinetic energy and velocity distribution due to collision between the big mass of the arterial wall and the small mass of blood cells must be considered as well.

  13. Performance evaluation of a flow-down collecting solar system; Ryuka shunetsushiki solar system no seino hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Kanayama, K; Li, X; Baba, H; Endo, N [Kitami Institute of Technology, (Japan)

    1997-11-25

    The paper evaluated performance of a flow-down collecting solar system. The solar heat pump PV system is composed of a solar system, heat pump and PV, of which the heat collecting portion is a water-use horizontal evacuated double glass tube solar collector. As a result of the performance measurement, the necessity of fundamental improvement arose. Under an idea of disproving common sense of the original forced circulation solar system, a system was designed in which heat is collected by making the heat media reversely circulate and flow down in accordance with gravity. When the flow rate was 2m{sup 3}/h, the collecting rate reached a maximum, approximately 54% (36.9% before improvement). When the flow rate was 1.3-1.5m{sup 3}/h, the system can realize the maximum merit, and the collecting efficiency became approximately 50%. Helped by reduction in consumed power, the average system performance coefficient reached more than 85% (28.9% before improvement). The obtainable energy rate rapidly increased to 2.9 times more than before improvement. Further, the consumed power of pump was decreased 65% from before improvement when the flow rate was 2.4m{sup 3}/h. 2 refs., 5 figs.

  14. Electronic remote blood issue: a combination of remote blood issue with a system for end-to-end electronic control of transfusion to provide a "total solution" for a safe and timely hospital blood transfusion service.

    Science.gov (United States)

    Staves, Julie; Davies, Amanda; Kay, Jonathan; Pearson, Oliver; Johnson, Tony; Murphy, Michael F

    2008-03-01

    The rapid provision of red cell (RBC) units to patients needing blood urgently is an issue of major importance in transfusion medicine. The development of electronic issue (sometimes termed "electronic crossmatch") has facilitated rapid provision of RBC units by avoidance of the serologic crossmatch in eligible patients. A further development is the issue of blood under electronic control at blood refrigerator remote from the blood bank. This study evaluated a system for electronic remote blood issue (ERBI) developed as an enhancement of a system for end-to-end electronic control of hospital transfusion. Practice was evaluated before and after its introduction in cardiac surgery. Before the implementation of ERBI, the median time to deliver urgently required RBC units to the patient was 24 minutes. After its implementation, RBC units were obtained from the nearby blood refrigerator in a median time of 59 seconds (range, 30 sec to 2 min). The study also found that unused requests were reduced significantly from 42 to 20 percent, the number of RBC units issued reduced by 52 percent, the number of issued units that were transfused increased from 40 to 62 percent, and there was a significant reduction in the workload of both blood bank and clinical staff. This study evaluated a combination of remote blood issue with an end-to-end electronically controlled hospital transfusion process, ERBI. ERBI reduced the time to make blood available for surgical patients and improved the efficiency of hospital transfusion.

  15. Distinguishing infected from noninfected abdominal fluid collections after surgery: an imaging, clinical, and laboratory-based scoring system.

    Science.gov (United States)

    Gnannt, Ralph; Fischer, Michael A; Baechler, Thomas; Clavien, Pierre-Alain; Karlo, Christoph; Seifert, Burkhardt; Lesurtel, Mickael; Alkadhi, Hatem

    2015-01-01

    Mortality from abdominal abscesses ranges from 30% in treated cases up to 80% to 100% in patients with undrained or nonoperated abscesses. Various computed tomographic (CT) imaging features have been suggested to indicate infection of postoperative abdominal fluid collections; however, features are nonspecific and substantial overlap between infected and noninfected collections exists. The purpose of this study was to develop and validate a scoring system on the basis of CT imaging findings as well as laboratory and clinical parameters for distinguishing infected from noninfected abdominal fluid collections after surgery. The score developmental cohort included 100 consecutive patients (69 men, 31 women; mean age, 58 ± 17 years) who underwent portal-venous phase CT within 24 hours before CT-guided intervention of postoperative abdominal fluid collections. Imaging features included attenuation (Hounsfield unit [HU]), volume, wall enhancement and thickness, fat stranding, as well as entrapped gas of fluid collections. Laboratory and clinical parameters included diabetes, intake of immunosuppressive drugs, body temperature, C-reactive protein, and leukocyte blood cell count. The score was validated in a separate cohort of 30 consecutive patients (17 men, 13 women; mean age, 51 ± 15 years) with postoperative abdominal fluid collections. Microbiologic analysis from fluid samples served as the standard of reference. Diabetes, body temperature, C-reactive protein, attenuation of the fluid collection (in HUs), wall enhancement and thickness of the wall, adjacent fat stranding, as well as entrapped gas within the fluid collection were significantly different between infected and noninfected collections (P collection (in HUs), as well as entrapped gas as significant independent predictors of infection (P collection, ≥ 20 HU: 4 points; entrapped gas: 3 points). The model was well calibrated (Hosmer-Lemeshow test, P = 0.36). In the validation cohort, scores of 2 or lower

  16. Artificial heart system thermal converter and blood pump component research and development

    International Nuclear Information System (INIS)

    Pouchot, W.D.; Bifano, N.J.; Hanson, J.P.

    1975-01-01

    A bench model version of a nuclear-powered artificial heart system to be used as a replacement for the natural heart was constructed and tested as a part of a broader U. S. ERDA program. The objective of the broader program has been to develop a prototype of a fully implantable nuclear-powered total artificial heart system powered by the thermal energy of plutonium-238 and having minimum weight and volume and a minimum life of ten years. As a forward step in this broader program, component research and development has been carried out directed towards a fully implantable and advanced version of the bench model (IVBM). Some of the results of the component research and development effort on a Stirling engine, blood pump drive mechanisms, and coupling mechanisms are presented. The Stirling-mechanical system under development is shown. There are three major subassemblies: the thermal converter, the coupling mechanism, and the blood pump drive mechanism. The thermal converter uses a Stirling cycle to convert the heat of the plutonium-238 fueled heat source to a rotary shaft power output. The coupling mechanism changes the orientation of the output shaft by 90 degrees and transmits the pumping power by wire-wound core flexible shafting to the pumping mechanism. The coupling mechanism also provides routing of the coolant lines which carry the cycle waste heat from the thermal converter to the blood pump. The change in orientation of the thermal converter output shaft is for convenience in implanting in a calf. This orientation of thermal converter to blood pump seemed to give the best overall system fit in a calf based on fit trials with wooden models in a calf cadaver

  17. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN/MG), Belo Horizonte, MG (Brazil)], e-mail: gas@cdtn.br, e-mail: pls@cdtn.br, e-mail: fcp@cdtn.br, e-mail: lcmb@cdtn.br, e-mail: pabloag@cdtn.br

    2009-07-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  18. Blood compounds irradiation process: assessment of absorbed dose using Fricke and Thermoluminescent dosimetric systems

    International Nuclear Information System (INIS)

    Soares, Gabriela de Amorim; Squair, Peterson Lima; Pinto, Fausto Carvalho; Belo, Luiz Claudio Meira; Grossi, Pablo Andrade

    2009-01-01

    The assessment of gamma absorbed doses in irradiation facilities allows the quality assurance and control of the irradiation process. The liability of dose measurements is assign to the metrological procedures adopted including the uncertainty evaluation. Fricke and TLD 800 dosimetric systems were used to measure absorbed dose in the blood compounds using the methodology presented in this paper. The measured absorbed doses were used for evaluating the effectiveness of the irradiation procedure and the gamma dose absorption inside the irradiation room of a gamma irradiation facility. The radiation eliminates the functional and proliferative capacities of donor T-lymphocytes, preventing Transfusion associated graft-versus-host disease (TA-GVHD), a possible complication of blood transfusions. The results show the applicability of such dosimetric systems in quality assurance programs, assessment of absorbed doses in blood compounds and dose uniformity assign to the blood compounds irradiation process by dose measurements in a range between 25 Gy and 100 Gy. (author)

  19. Development of blood transfusion service in Sultanate of Oman

    Directory of Open Access Journals (Sweden)

    Joshi Sanmukh

    2010-01-01

    Full Text Available Background: Sultanate of Oman is geographically situated in south-west of Asia, having common borders on western side by the land with United Arab Emirates, Saudi Arabia and Yemen and with the Arabian Sea and the Gulf of Oman in the east and the north respectively. The country enjoys one of the best health care facilities including blood transfusion services in the region. Study design: Information was collected through informal personal interviews, digging out the past records, and the report presentations at various forums. Results: A modest start by providing blood units through import, the country is now self-reliant on procuring blood units from voluntary non-remunerate blood donors within the sultanate. A steady growth of blood banks is witnessed in every aspect of blood banking including blood collection, blood processing and supply. Various modalities are adapted in promoting voluntary blood donation programme. Conclusion: Sultanate of Oman has created one of the best blood transfusion services in the region in providing safe blood for transfusion through voluntary donation, a use of blood components and irradiating blood products.

  20. STUDY ON KNOWLEDGE AND ATTITUDE OF BLOOD DONORS TOWARDS BLOOD DONATION IN BIJAPUR DISTRICT

    Directory of Open Access Journals (Sweden)

    Himanshu Dilip

    2016-05-01

    Full Text Available BACKGROUND Blood is the living force of our body and there is no substitute for it. It can only be replaced through blood donation. Blood donation can save millions of lives. Demand for safe blood is increasing every day because of increase in population, increased life-expectancy and urbanisation, trauma cases, major surgeries, patients with regular transfusion requirement like cases of thalassaemia, haemophilia and chemotherapy. To increase blood donor recruitment and retention, the level of knowledge and attitude of blood donors towards blood donation must be known as this affects donor’s decision of blood donation. This information helps for tailoring targeted programs and campaigns in order to recruit more people as regular voluntary blood donors. OBJECTIVE To assess the level of knowledge and attitude regarding blood donation amongst blood donors in Bijapur district, Karnataka. MATERIALS AND METHODS Blood donors registered for blood donation in B.L.D.E. University’s Shri B. M. Patil Medical College, Hospital and Research Centre’s Blood Bank, in Bijapur district were included in this study. The data was collected by filling a self-administered structured questionnaire. The questionnaire was administered to all the donors ready to participate in the study. Questionnaires were distributed at the time of registration and were collected after filling during the refreshment period. Also one-on-one individual interviews were conducted to know about the blood donation experience and willingness of donor for future donation. A scoring mechanism was used to understand the level of knowledge, a score of one was given for each correct response and zero for wrong and unaware response. RESULTS In this study, it was found that 61% of the participants had average knowledge [Cumulative score 4-6], 34% of the participants had good knowledge [Cumulative score 7-8] and 5% of participants had poor knowledge [Cumulative score 0-3] about the different

  1. Wireless data collection system for real-time arterial travel time estimates.

    Science.gov (United States)

    2011-03-01

    This project pursued several objectives conducive to the implementation and testing of a Bluetooth (BT) based system to collect travel time data, including the deployment of a BT-based travel time data collection system to perform comprehensive testi...

  2. Changes in the nervous system state and peripheral blood parameters under benzene intoxication during an experiment

    Directory of Open Access Journals (Sweden)

    R.A. Orujov

    2017-12-01

    Full Text Available Benzene is a widely spread chemical health risk factor. Our research goal was to examine the nervous system state and the blood system state under benzene intoxication during an experiment. An acute experiment was performed on 45 white mice with 5-fold poisoning with benzene; a chronic one was performed on 72 rabbits being under inhalation exposure to benzene during 4 months, its concentrations increasing and fluctuating. We determined the following blood parameters: number of reticulocytes, eosinophils, basocytes, and erythrocytes; erythrocytes sedimentation rate; blood clotting period; blood clot retraction; plasma re-calcification period; plasma tolerance to heparin; prothrombin time; prothrombin index; fibrinogen concentration; blood fibrinolytic activity; acetylcholine and choline esterase contents. We also determined adrenalin, noradrenalin, dopamine, and dihydroxyphenylalanine contents in urine. Acute experiments results revealed that one-time exposure to benzene exerted a narcotic effect on the central nervous system which had an excitation phase and inhibition phase. Under a repeat exposure to benzene animals' drug intoxication was shorter. And here neutrophils / leucocytes gradient first increased to 139.5 % from its standards value and then when down under consequent intoxications. We detected relevant changes in morphological picture of animals' peripheral blood and their central and vegetative nervous system under chronic exposure to intermittent and increasing benzene concentrations. So, our research revealed that effects exerted by benzene in small concentrations led to apparent shifts in white blood and catecholamines (adrenalin, noradrenalin, dopamine, and dihydroxyphenylalanine. We also detected certain signs that cate-cholamines endogenous reserves (dihydroxyphenylalanine were depleted and, and also signs of eosinophils-basocytes disso-ciation; such prognostic signs were considered to be unfavorable as it was exactly at that

  3. Hand held data collection and monitoring system for nuclear facilities

    Science.gov (United States)

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-26

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs.

  4. Hand held data collection and monitoring system for nuclear facilities

    International Nuclear Information System (INIS)

    Brayton, D.D.; Scharold, P.G.; Thornton, M.W.; Marquez, D.L.

    1999-01-01

    Apparatus and method is disclosed for a data collection and monitoring system that utilizes a pen based hand held computer unit which has contained therein interaction software that allows the user to review maintenance procedures, collect data, compare data with historical trends and safety limits, and input new information at various collection sites. The system has a means to allow automatic transfer of the collected data to a main computer data base for further review, reporting, and distribution purposes and uploading updated collection and maintenance procedures. The hand held computer has a running to-do list so sample collection and other general tasks, such as housekeeping are automatically scheduled for timely completion. A done list helps users to keep track of all completed tasks. The built-in check list assures that work process will meet the applicable processes and procedures. Users can hand write comments or drawings with an electronic pen that allows the users to directly interface information on the screen. 15 figs

  5. Simple, miniaturized blood plasma extraction method.

    Science.gov (United States)

    Kim, Jin-Hee; Woenker, Timothy; Adamec, Jiri; Regnier, Fred E

    2013-12-03

    A rapid plasma extraction technology that collects a 2.5 μL aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid-liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 μM, linear from 1 to 40 μM, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to

  6. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies

    OpenAIRE

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung-Hoi

    2016-01-01

    Background ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. Methods In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to...

  7. Design of the CERN MEDICIS Collection and Sample Extraction System

    CERN Document Server

    Brown, Alexander

    MEDICIS is a new facility at CERN ISOLDE that aims to produce radio-isotopes for medical research. Possible designs for the collection and transport system for the collection of radio-isotopes was investigated. A system using readily available equipment was devised with the the aim of keeping costs to a minimum whilst maintaining the highest safety standards. FLUKA, a Monte Carlo radiation transport code, was used to simulate the radiation from the isotopes to be collected. Of the isotopes to be collected 44Sc was found to give the largest dose by simulating the collection of all isotopes of interest to CERN’s MEDICIS facility, for medical research. The simulations helped guide the amount of shielding used in the final design. Swiss Regulations stipulating allowed activity level of individual isotopes was also considered within the body of the work.

  8. A multi-structural and multi-functional integrated fog collection system in cactus.

    Science.gov (United States)

    Ju, Jie; Bai, Hao; Zheng, Yongmei; Zhao, Tianyi; Fang, Ruochen; Jiang, Lei

    2012-01-01

    Multiple biological structures have demonstrated fog collection abilities, such as beetle backs with bumps and spider silks with periodic spindle-knots and joints. Many Cactaceae species live in arid environments and are extremely drought-tolerant. Here we report that one of the survival systems of the cactus Opuntia microdasys lies in its efficient fog collection system. This unique system is composed of well-distributed clusters of conical spines and trichomes on the cactus stem; each spine contains three integrated parts that have different roles in the fog collection process according to their surface structural features. The gradient of the Laplace pressure, the gradient of the surface-free energy and multi-function integration endow the cactus with an efficient fog collection system. Investigations of the structure-function relationship in this system may help us to design novel materials and devices to collect water from fog with high efficiencies.

  9. A multi-structural and multi-functional integrated fog collection system in cactus

    Science.gov (United States)

    Ju, Jie; Bai, Hao; Zheng, Yongmei; Zhao, Tianyi; Fang, Ruochen; Jiang, Lei

    2012-01-01

    Multiple biological structures have demonstrated fog collection abilities, such as beetle backs with bumps and spider silks with periodic spindle-knots and joints. Many Cactaceae species live in arid environments and are extremely drought-tolerant. Here we report that one of the survival systems of the cactus Opuntia microdasys lies in its efficient fog collection system. This unique system is composed of well-distributed clusters of conical spines and trichomes on the cactus stem; each spine contains three integrated parts that have different roles in the fog collection process according to their surface structural features. The gradient of the Laplace pressure, the gradient of the surface-free energy and multi-function integration endow the cactus with an efficient fog collection system. Investigations of the structure–function relationship in this system may help us to design novel materials and devices to collect water from fog with high efficiencies. PMID:23212376

  10. Blood Conservation.

    Science.gov (United States)

    Martin, Jeremiah T; Ferraris, Victor A

    2015-01-01

    Patient blood management requires multi-modality and multidisciplinary collaboration to identify patients who are at increased risk of requiring blood transfusion and therefore decrease exposure to blood products. Transfusion is associated with poor postoperative outcomes, and guidelines exist to minimize transfusion requirements. This review highlights recent studies and efforts to apply patient blood management across disease processes and health care systems. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. A novel non-imaging optics based Raman spectroscopy device for transdermal blood analyte measurement

    Directory of Open Access Journals (Sweden)

    Chae-Ryon Kong

    2011-09-01

    Full Text Available Due to its high chemical specificity, Raman spectroscopy has been considered to be a promising technique for non-invasive disease diagnosis. However, during Raman excitation, less than one out of a million photons undergo spontaneous Raman scattering and such weakness in Raman scattered light often require highly efficient collection of Raman scattered light for the analysis of biological tissues. We present a novel non-imaging optics based portable Raman spectroscopy instrument designed for enhanced light collection. While the instrument was demonstrated on transdermal blood glucose measurement, it can also be used for detection of other clinically relevant blood analytes such as creatinine, urea and cholesterol, as well as other tissue diagnosis applications. For enhanced light collection, a non-imaging optical element called compound hyperbolic concentrator (CHC converts the wide angular range of scattered photons (numerical aperture (NA of 1.0 from the tissue into a limited range of angles accommodated by the acceptance angles of the collection system (e.g., an optical fiber with NA of 0.22. A CHC enables collimation of scattered light directions to within extremely narrow range of angles while also maintaining practical physical dimensions. Such a design allows for the development of a very efficient and compact spectroscopy system for analyzing highly scattering biological tissues. Using the CHC-based portable Raman instrument in a clinical research setting, we demonstrate successful transdermal blood glucose predictions in human subjects undergoing oral glucose tolerance tests.

  12. Radioactive and industrial waste water collection system study, Phase I

    International Nuclear Information System (INIS)

    1993-01-01

    Phase I of the Radioactive Liquid Waste (RLW) Collection System Study has been completed, and the deliverables for this portion of the study are enclosed. The deliverables include: The Work Break-down Structure (WBS) for Phase II; The Annotated Outline for the Collection Study Report; The Process Flow Diagrams (PFD) of the RLW collection system based on current literature and knowledge; The Configuration database; The Reference Index, listing all currently held documents of the RLW collection system; The Reference Drawing Index listing all currently held, potentially applicable, drawings reviewed during the PFD development; The Regulation Identification Document for RCRA and CWA; The Regulation Database for RCRA and CWA; The Regulation Review Log, including statements justifying the non-applicability of certain regulations; Regulation Library, including the photocopied regulations with highlighted text for RCRA and CWA; The summary of RTG's waste water treatment plant design experience and associated regulations on which RTG based the design of these treatment facilities; TA-50 Influent Database; Radioactive Liquid Waste Stream Characterization Database

  13. Evaluation of 12 blood glucose monitoring systems for self-testing: system accuracy and measurement reproducibility.

    Science.gov (United States)

    Freckmann, Guido; Baumstark, Annette; Schmid, Christina; Pleus, Stefan; Link, Manuela; Haug, Cornelia

    2014-02-01

    Systems for self-monitoring of blood glucose (SMBG) have to provide accurate and reproducible blood glucose (BG) values in order to ensure adequate therapeutic decisions by people with diabetes. Twelve SMBG systems were compared in a standardized manner under controlled laboratory conditions: nine systems were available on the German market and were purchased from a local pharmacy, and three systems were obtained from the manufacturer (two systems were available on the U.S. market, and one system was not yet introduced to the German market). System accuracy was evaluated following DIN EN ISO (International Organization for Standardization) 15197:2003. In addition, measurement reproducibility was assessed following a modified TNO (Netherlands Organization for Applied Scientific Research) procedure. Comparison measurements were performed with either the glucose oxidase method (YSI 2300 STAT Plus™ glucose analyzer; YSI Life Sciences, Yellow Springs, OH) or the hexokinase method (cobas(®) c111; Roche Diagnostics GmbH, Mannheim, Germany) according to the manufacturer's measurement procedure. The 12 evaluated systems showed between 71.5% and 100% of the measurement results within the required system accuracy limits. Ten systems fulfilled with the evaluated test strip lot minimum accuracy requirements specified by DIN EN ISO 15197:2003. In addition, accuracy limits of the recently published revision ISO 15197:2013 were applied and showed between 54.5% and 100% of the systems' measurement results within the required accuracy limits. Regarding measurement reproducibility, each of the 12 tested systems met the applied performance criteria. In summary, 83% of the systems fulfilled with the evaluated test strip lot minimum system accuracy requirements of DIN EN ISO 15197:2003. Each of the tested systems showed acceptable measurement reproducibility. In order to ensure sufficient measurement quality of each distributed test strip lot, regular evaluations are required.

  14. Institutional blood glucose monitoring system for hospitalized patients: an integral component of the inpatient glucose control program.

    Science.gov (United States)

    Boaz, Mona; Landau, Zohar; Matas, Zipora; Wainstein, Julio

    2009-09-01

    The ability to measure patient blood glucose levels at bedside in hospitalized patients and to transmit those values to a central database enables and facilitates glucose control and follow-up and is an integral component in the care of the hospitalized diabetic patient. The goal of this study was to evaluate the performance of an institutional glucometer employed in the framework of the Program for the Treatment of the Hospitalized Diabetic Patient (PTHDP) at E. Wolfson Medical Center, Holon, Israel. As part of the program to facilitate glucose control in hospitalized diabetic patients, an institutional glucometer was employed that permits uploading of data from stands located in each inpatient department and downloading of that data to a central hospital-wide database. Blood glucose values from hospitalized diabetic patients were collected from August 2007 to October 2008. The inpatient glucose control program was introduced gradually beginning January 2008. During the follow-up period, more than 150,000 blood glucose measures were taken. Mean glucose was 195.7 +/- 99.12 mg/dl during the follow-up period. Blood glucose values declined from 206 +/- 105 prior to PTHDP (August 2007-December 2007) to 186 +/- 92 after its inception (January 2008-October 2008). The decline was associated significantly with time (r = 0.11, p < 0.0001). The prevalence of blood glucose values lower than 60 mg/dl was 1.48% [95% confidence interval (CI) 0.36%] prior to vs 1.55% (95% CI 0.37%) following implementation of the PTHDP. Concomitantly, a significant increase in the proportion of blood glucose values between 80 and 200 mg/dl was observed, from 55.5% prior to program initiation vs 61.6% after program initiation (p < 0.0001). The present study was designed to observe changes in institution-wide glucose values following implementation of the PTHDP. Information was extracted from the glucometer system itself. Because the aforementioned study was not a clinical trial, we cannot rule out

  15. Developmental stages of fish blood flukes, Cardicola forsteri and Cardicola opisthorchis (Trematoda: Aporocotylidae), in their polychaete intermediate hosts collected at Pacific bluefin tuna culture sites in Japan.

    Science.gov (United States)

    Ogawa, Kazuo; Shirakashi, Sho; Tani, Kazuki; Shin, Sang Phil; Ishimaru, Katsuya; Honryo, Tomoki; Sugihara, Yukitaka; Uchida, Hiro'omi

    2017-02-01

    Farming of Pacific bluefin tuna (PBT), Thunnus orientalis, is a rapidly growing industry in Japan. Aporocotylid blood flukes of the genus Cardicola comprising C. orientalis, C. opisthorchis and C. forsteri are parasites of economic importance for PBT farming. Recently, terebellid polychaetes have been identified as the intermediate hosts for all these parasites. We collected infected polychaetes, Terebella sp., the intermediate host of C. opisthorchis, from ropes and floats attached to tuna cages in Tsushima, Nagasaki Prefecture, Japan. Also, Neoamphitrite vigintipes (formerly as Amphitrite sp. sensu Shirakashi et al., 2016), the intermediate host of C. forsteri, were collected from culture cages in Kushimoto, Wakayama Prefecture, Japan. The terebellid intermediate hosts harbored the sporocysts and cercariae in their body cavity. Developmental stages of these blood flukes were molecularly identified using species specific PCR primers. In this paper, we describe the cercaria and sporocyst stages of C. opisthorchis and C. forsteri and compare their morphological characteristics among three Cardicola blood flukes infecting PBT. We also discuss phylogenetic relations of the six genera of the terebellid intermediate hosts (Artacama, Lanassa, Longicarpus, Terebella, Nicolea and Neoamphitrite) of blood flukes infecting marine fishes, based on their morphological characters. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Impact of the May 12, 2008, Earthquake on blood donations across five Chinese blood centers.

    Science.gov (United States)

    Liu, Jing; Huang, Yi; Wang, Jingxing; Bi, Xinhong; Li, Julin; Lu, Yunlai; Wen, Xiuqiong; Yao, Fuzhu; Dong, Xiangdong; He, Weilan; Huang, Mei; Ma, Hongli; Mei, Heili; King, Melissa; Wright, David J; Ness, Paul M; Shan, Hua

    2010-09-01

    On May 12, 2008, a severe earthquake struck China's Sichuan Province. The nationwide outpouring of charity resulted in a surge of subsequent blood donations. The quantity and quality of these donations were examined in comparison with routine donations. Whole blood and apheresis donations from five geographically different blood centers collected within 1 week postearthquake were compared with those collected during the rest of the year. Regional differences, demographic characteristics, first-time and repeat donor status, and infectious disease screening markers associated with these donations were compared by earthquake status using chi-square statistics. Poisson regression analysis examined the number of daily donations by earthquake status after adjusting for center, day of week, and seasonal variations. The number of daily donations across five blood centers increased from 685 on a typical day to 1151 in the postearthquake week. The surge was observed in both sexes and across different education levels, age, and ethnicity groups and three blood centers and was significant after adjusting for confounding covariates. The influx of first-time donors (89.5%) was higher than that of repeat donors (34%). There was a significant change in the overall screening reactive marker rates excluding alanine aminotransferase (2.06% vs. 1.72%% vs. 4.96%). However, when the individual screening test was analyzed separately, no significant differences were found. Timely donations in response to a disaster are crucial to ensure emergency blood transfusion. The dramatically increased postearthquake donations suggest that Chinese blood centers are capable of handling emergency blood needs. Measures to maintain blood safety should be taken in times of emergency. © 2010 American Association of Blood Banks.

  17. Perioperative blood ordering optimization process using information from an anesthesia information management system.

    Science.gov (United States)

    Rinehart, Joseph B; Lee, Tiffany C; Kaneshiro, Kayleigh; Tran, Minh-Ha; Sun, Coral; Kain, Zeev N

    2016-04-01

    As part of ongoing perioperative surgical home implantation process, we applied a previously published algorithm for creation of a maximum surgical blood order schedule (MSBOS) to our operating rooms. We hypothesized that using the MSBOS we could show a reduction in unnecessary preoperative blood testing and associated costs. Data regarding all surgical cases done at UC Irvine Health's operating rooms from January 1, 2011, to January 1, 2014 were extracted from the anesthesia information management systems (AIMS). After the data were organized into surgical specialties and operative sites, blood order recommendations were generated based on five specific case characteristics of the group. Next, we assessed current ordering practices in comparison to actual blood utilization to identify potential areas of wastage and performed a cost analysis comparing the annual hospital costs from preoperative blood orders if the blood order schedule were to be followed to historical practices. Of the 19,138 patients who were categorized by the MSBOS as needing no blood sample, 2694 (14.0%) had a type and screen (T/S) ordered and 1116 (5.8%) had a type and crossmatch ordered. Of the 6073 procedures where MSBOS recommended only a T/S, 2355 (38.8%) had blood crossmatched. The cost analysis demonstrated an annual reduction in actual hospital costs of $57,335 with the MSBOS compared to historical blood ordering practices. We showed that the algorithm for development of a multispecialty blood order schedule is transferable and yielded reductions in preoperative blood product screening at our institution. © 2016 AABB.

  18. The sewer collection system, the first treatment step

    International Nuclear Information System (INIS)

    Rustia, B.M.; Dickerson, J.R.

    2002-01-01

    'Full text:' The Civil Engineering Research Foundation's (CERF) Environmental Technology Evaluation Center (EvTEC) conducted an evaluation of a microbial treatment additive that converts the entire sewer collection system into an efficient high-speed treatment step. The technology claims to reduce total suspended solids (TSS) by > 60% and carbonaceous biological oxygen demand (CBOD), simultaneously by > 30% before it reaches the treatment plant. The technology uses pump station wet wells as the network nodes to add the microbial treatment to the waste water collection system This process uses the natural retention time in the sewer coupled with the addition of an extremely concentrated mixture of select, symbiotic, facultative microbes, which degrade the waste en route to the treatment plant. These bacteria do not produce odorous compounds and they replace the sulfur-reducing-bacteria (SRB) in the biomass on the walls of the force mains and on the wet perimeter of the gravity sewer piping by 'competitive exclusion.' This microbial substitution is achieved by the high quantity of organisms injected into the collection system. This reduces the sulfides in the wastewater thereby reducing the odor, along with greatly reducing the corrosion elements, which attack the piping in a sewer collection system. The objective of EvTEC evaluation was to verify the performance and reliability of such a microbial additive to treat wastewater and reduce plant 'sludges,' or biosolids. Among other performance issues, the evaluation addressed the technology's ability to treat domestic wastewater flows over an extended time period (i.e., greater than 3 months, 6 months, 12 months..., etc.) and to see if the benefits are improved during particular times of year. The benefits to using the additive include reducing the biosolids produced at the treatment plant and increasing the treatment plant's efficiency and capacity. This in turn helped reduce operating costs without requiring a large

  19. Iron deficiency among blood donors

    DEFF Research Database (Denmark)

    Rigas, A S; Pedersen, O B; Magnussen, K

    2017-01-01

    Blood components collected from blood donors are an invaluable part of modern-day medicine. A healthy blood donor population is therefore of paramount importance. The results from the Danish Blood Donor Study (DBDS) indicate that gender, number of previous donations, time since last donation...... and menopausal status are the strongest predictors of iron deficiency. Only little information on the health effects of iron deficiency in blood donors exits. Possibly, after a standard full blood donation, a temporarily reduced physical performance for women is observed. However, iron deficiency among blood...... donors is not reflected in a reduced self-perceived mental and physical health. In general, the high proportion of iron-deficient donors can be alleviated either by extending the inter-donation intervals or by guided iron supplementation. The experience from Copenhagen, the Capital Region of Denmark...

  20. The Unicorn Collection Management System: Its Structure and Features.

    Science.gov (United States)

    Young, Jacky; Veatch, James R., Jr.

    1988-01-01

    Discusses the design principles behind the Unicorn Collection Management System, an integrated library system which includes modules for bibliographic and inventory control, circulation, academic reserves, serials control, authority control, acquisition, electronic mail, bulletin board, and enhanced public access. The flexibility of the system is…

  1. The status of blood safety in ECO member states

    Science.gov (United States)

    Seighali, Fariba; Hosseini Divkolaye, Nasim S.; Koohi, Ebrahim; Pourfathollah, Ali A.; Rahmani, Ahmad M.

    2015-01-01

    Background Access to the information concerning blood safety is essential for managing problems and overcoming the challenges that are faced in any given region. Information on the availability and safety of blood in countries of the Economic Cooperation Organisation (ECO) is largely lacking. To address this problem, the Iranian Blood Transfusion Organisation, in collaboration with other ECO member states, initiated a research project in 2009 to collect, analyse and compare statistics on blood safety in the region. Materials and methods A modified and summarised version of the Global Database on Blood Safety (GDBS) questionnaire was used to collect data. The questionnaire was sent to all ten countries in the ECO region. The heads of the national transfusion services or focal points were requested to complete the form. Related literature and websites were also reviewed. Results Only three countries (Afghanistan, Iran and Turkey) completed the questionnaire, while other countries provided their available data on some parts of the questionnaire. The number of donations per year varied from 5 to 27/1,000 population. The rate of donors positive for human immunodeficiency virus ranged from 0.003% to 0.2%. The rate of donors positive for hepatitis C virus antibody varied from 0.05% to 3.9% while that of hepatitis B virus surface antigen ranged from 0.15% to 3.91% respectively. Discussion There is very clear diversity in blood transfusion services among ECO member states. Most countries in the region do not have a data-recording system. It is generally estimated that the need for blood is much higher than the supply in this region. Deficiencies in donor screening and a high prevalence of transfusion-transmitted infections are other important challenges. PMID:26192779

  2. transfusion transmissible viral infections among potential blood

    African Journals Online (AJOL)

    boaz

    Blood sample was spun on a bench centrifuge at 3,000rpm for 10 minutes to obtain serum. Serum or plasma was separated immediately. Data Collection and Laboratory Methods. A survey of the blood sample of the prospective donors at the Blood Bank, University College. Hospital (UCH) Ibadan was conducted between.

  3. Relationship of blood lead levels to obstetric outcome

    Energy Technology Data Exchange (ETDEWEB)

    Angell, N.F.; Lavery, J.P.

    1982-01-01

    Lead represents a significant environmental hazard to pregnant women and their offspring. Exposure to high environmental levels of lead has been associated with spontaneous abortion, premature rupture of fetal membranes (PROM), and preterm delivery. The relationship between lower exposures and obstetric complications is unknown. The concentration of lead in the blood was measured in 635 specimens of umbilical cord blood collected at delivery. No relationship was found between concentrations of lead in cord blood and the incidence of PROM, preterm delivery, preeclampsia, or meconium staining. Maternal and infant capillary blood was collected 24 hours post partum from 154 of these deliveries. The concentrations of lead in the blood did not vary significantly among cord, infant, and maternal samples, and the three measurements were highly correlated. Levels of zinc protoporphyrin (ZnP) were increased in cord blood as compared with mothers' blood, but no concentration-response relationships between the ratio of cord ZnP to maternal ZnP and lead were found.

  4. The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements.

    OpenAIRE

    Majid, A; Heaney, D C; Padmanabhan, N; Spooner, R

    1996-01-01

    The effect of order of draw when taking blood into tubes containing additive was investigated in 47 medical inpatients; 12 of these patients acted as a control group. The samples were analysed in the order in which they were withdrawn. The results of potassium and calcium concentrations did not differ significantly between groups. Manufacturers recommend a specific order of draw when taking blood using vacuum based blood collection systems, which are routinely used in many hospitals. The resu...

  5. Nanoparticles and the blood coagulation system. Part I: benefits of nanotechnology.

    Science.gov (United States)

    Ilinskaya, Anna N; Dobrovolskaia, Marina A

    2013-05-01

    Nanotechnology is proven to provide certain benefits in drug delivery by improving solubility, increasing uptake to target sites and changing pharmacokinetics profiles of traditional drugs. Since properties of many materials change tremendously at the nanoscale levels, nanotechnology is also being explored in various industrial applications. As such, nanoparticles are rapidly entering various areas of industry, biology and medicine. The benefits of using nanotechnology for industrial and biomedical applications are often tempered by concerns about the safety of these new materials. One such area of concern includes their effect on the immune system. While nanoparticle interactions with various constituents of the immune system have been reviewed before, little attention was given to nanoparticle effects on the blood coagulation system. Nanoparticle interface with the blood coagulation system may lead to either benefits to the host or adverse reactions. This article reviews recent advances in our understanding of nanoparticle interactions with plasma coagulation factors, platelets, endothelial cells and leukocytes. Part I is focused on desirable interactions between nanoparticles and the coagulation system, and discusses benefits of using nanotechnology to intervene in coagulation disorders. Undesirable interactions posing safety concerns are covered in part II, which will be published in the June issue of Nanomedicine.

  6. Gene expression differences between PAXgene and Tempus blood RNA tubes are highly reproducible between independent samples and biobanks.

    Science.gov (United States)

    Skogholt, Anne Heidi; Ryeng, Einar; Erlandsen, Sten Even; Skorpen, Frank; Schønberg, Svanhild A; Sætrom, Pål

    2017-03-23

    Gene expression profiling from blood is sensitive to technology choices. For example, the main blood RNA collection systems-the PAXgene and Tempus tubes-differently influence RNA expression signatures. The aim of this study was to establish a common RNA isolation protocol for these two systems and investigate if it could reduce the differences in gene expression between them. We collected identical blood samples on the PAXgene and Tempus systems and retrieved blood samples from two independent biobanks-NOWAC and HUNT3-which are based on PAXgene and Tempus, respectively. High-quality RNA was extracted from both sampling systems by using their original protocols and our common modified protocol, and were profiled on Illumina microarrays. Regardless of the protocol used, we found most of the measured transcripts to be differently affected by the two sampling systems. However, our modified protocol reduced the number of transcripts that were significantly differentially expressed between PAXgene and Tempus by approximately 50%. Expression differences between PAXgene and Tempus were highly reproducible both between protocols and between different independent sample sets (Pearson correlation 0.563-0.854 across 47323 probes). Moreover, the modified protocol increased the microRNA output of the system with lowest microRNA yield, the PAXgene system. Most transcripts are affected by the choice of sampling system, but these effects are highly reproducible between independent samples. We propose that by running a control experiment with samples on both systems in parallel with biologically relevant samples, researchers may adjust for technical differences between the sampling systems.

  7. Comparative Analysis of Clinical Samples Showing Weak Serum Reaction on AutoVue System Causing ABO Blood Typing Discrepancies.

    Science.gov (United States)

    Jo, Su Yeon; Lee, Ju Mi; Kim, Hye Lim; Sin, Kyeong Hwa; Lee, Hyeon Ji; Chang, Chulhun Ludgerus; Kim, Hyung Hoi

    2017-03-01

    ABO blood typing in pre-transfusion testing is a major component of the high workload in blood banks that therefore requires automation. We often experienced discrepant results from an automated system, especially weak serum reactions. We evaluated the discrepant results by the reference manual method to confirm ABO blood typing. In total, 13,113 blood samples were tested with the AutoVue system; all samples were run in parallel with the reference manual method according to the laboratory protocol. The AutoVue system confirmed ABO blood typing of 12,816 samples (97.7%), and these results were concordant with those of the manual method. The remaining 297 samples (2.3%) showed discrepant results in the AutoVue system and were confirmed by the manual method. The discrepant results involved weak serum reactions (serum reactions, samples from patients who had received stem cell transplants, ABO subgroups, and specific system error messages. Among the 98 samples showing ≤1+ reaction grade in the AutoVue system, 70 samples (71.4%) showed a normal serum reaction (≥2+ reaction grade) with the manual method, and 28 samples (28.6%) showed weak serum reaction in both methods. ABO blood tying of 97.7% samples could be confirmed by the AutoVue system and a small proportion (2.3%) needed to be re-evaluated by the manual method. Samples with a 2+ reaction grade in serum typing do not need to be evaluated manually, while those with ≤1+ reaction grade do.

  8. Central Gi(2) proteins, sympathetic nervous system and blood pressure regulation

    Czech Academy of Sciences Publication Activity Database

    Zicha, Josef

    2016-01-01

    Roč. 216, č. 3 (2016), s. 258-259 ISSN 1748-1708 Institutional support: RVO:67985823 Keywords : inhibitory G proteins * sympathetic nervous system * central blood pressure control Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 4.867, year: 2016

  9. 76 FR 79692 - Agency Information Collection Activities; Submission for Office of Management and Budget Review...

    Science.gov (United States)

    2011-12-22

    ... complaints of adverse reactions arising as a result of blood collection or transfusion. Each such report must... Regulations for Blood and Blood Components; and Requirements for Donor Testing, Donor Notification, and... of blood collection or transfusion to be fatal. The collecting facility is to report donor fatalities...

  10. The relation of abo and Rh blood groups, sex, age and myocardial infraction

    International Nuclear Information System (INIS)

    Siddiqui, Z.H.; Chaudhry, M.A.; Butt, H.

    2009-01-01

    The present studies have determined the relationship of myocardial infarction with ABO and Rh blood group system gender and age' in the population of Punjab province, Pakistan. One thousand and thirty patients of myocardial infarction were selected from Punjab Institute of Cardiology, Sheikh Zaid Hospital and Jinnah Hospital Lahore. All these patients were diagnosed by physicians according to standard methods. Blood group of patients was determined by agglutination method. Blood group data of same number of normal subjects was collected from blood banks and residential areas of Lahore city for comparison. A significant relationship was observed both for blood group A and Rh-negative in myocardial infarction patients. It was also observed that male individuals in age group of 51 -60 years are more vulnerable to myocardial infarction. (author)

  11. Impact of Angiotensin Type 1A Receptors in Principal Cells of the Collecting Duct on Blood Pressure and Hypertension.

    Science.gov (United States)

    Chen, Daian; Stegbauer, Johannes; Sparks, Matthew A; Kohan, Donald; Griffiths, Robert; Herrera, Marcela; Gurley, Susan B; Coffman, Thomas M

    2016-06-01

    The main actions of the renin-angiotensin system to control blood pressure (BP) are mediated by the angiotensin type 1 receptors (AT1Rs). The major murine AT1R isoform, AT1AR, is expressed throughout the nephron, including the collecting duct in both principal and intercalated cells. Principal cells play the major role in sodium and water reabsorption. Although aldosterone is considered to be the dominant regulator of sodium reabsorption by principal cells, recent studies suggest a role for direct actions of AT1R. To specifically examine the contributions of AT1AR in principal cells to BP regulation and the development of hypertension in vivo, we generated inbred 129/SvEv mice with deletion of AT1AR from principal cells (PCKO). At baseline, we found that BPs measured by radiotelemetry were similar between PCKOs and controls. During 1-week of low-salt diet (hypertension, there was a modest but significant attenuation of hypertension in PCKOs (163±6 mm Hg) compared with controls (178±2 mm Hg; Phypertension and epithelial sodium channel activation. © 2016 American Heart Association, Inc.

  12. On cerebrae blood circulation from data of radiocirculography in some diseases of central nervous system in children

    International Nuclear Information System (INIS)

    Dolgov, A.G.; Stroganova, L.I.; Chirkin, N.I.

    1980-01-01

    Results of radioisotope investigation of cerebral blood circulation in 202 children with different pathology of central nervous system are presented. Velocity of cerebral blood flow and time of semiaccumulation and semimoving a preparate were investigated by means of sup(113m)In. It is established that radiocirculography shows clearly the changes in the system of cerebral blood supply and in such diseases as vegetovascular distonia and hypertension syndrome, the radiocirculography data pass ahead the clinical picture

  13. Apheresis for collection of Ebola convalescent plasma in Liberia.

    Science.gov (United States)

    Brown, Jerry F; Rowe, Kathleen; Zacharias, Peter; van Hasselt, James; Dye, John M; Wohl, David A; Fischer, William A; Cunningham, Coleen K; Thielman, Nathan M; Hoover, David L

    2017-06-01

    This report describes initiation of apheresis capability in Liberia, Africa to support a clinical trial of convalescent plasma therapy for Ebola Virus Disease. A bloodmobile was outfitted in the United States as a four-bed apheresis unit with capabilities including pathogen reduction, electronic blood establishment computer system, designated areas for donor counseling and laboratory testing, and onboard electrical power generation. After air transport to Liberia, the bloodmobile was positioned at ELWA Hospital, Monrovia, and connected to the hospital's power grid. Liberian staff were trained to conduct donor screening, which included questionnaire and onsite blood typing and transfusion transmitted infection (TTI) testing, and plasma collection and processing. The bloodmobile was operational within 3 weeks after arrival of the advance team. Of 101 donors who passed the pre-screening questionnaire, 32 were deferred. Twenty-eight of ninty-nine tested survivors were deferred for positive transfusion transmitted infection (TTI) tests; twenty-one were positive for hepatitis B, hepatitis C, or human immunodeficiency virus. The majority of donors had type O blood; all but one were Rh positive. Forty-three survivors donated at least once; eighty-nine apheresis attempts resulted in eighty-one successful collections. Apheresis capability was emergently established in Liberia to support an efficacy trial of Ebola Convalescent Plasma. Extensive cooperation among multinational team members, engineers, logisticians, and blood safety technical personnel at the operational site was required to surmount challenges to execution posed by logistical factors. The high proportion of positive TTI tests supported the use of a pathogen reduction system to enhance product safety. J. Clin. Apheresis 32:175-181, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. ABO blood groups, Rhesus factor, and Behçet's disease.

    Science.gov (United States)

    Ozyurt, Kemal; Oztürk, Perihan; Gül, Mustafa; Benderli, Yasemin Cihan; Cölgeçen, Emine; Inci, Rahime

    2013-09-01

    Recently, numerous studies have been carried out to explain the genetics and immunopathogenesis of Behçet's disease (BD). There is still insufficient understanding of its etiopathogenesis, but substantial genetic and immune system abnormalities have been suggested. Several studies have shown remarkable associations of ABO blood groups with various diseases. This study investigated the relationship between ABO and Rhesus (D) blood groups and Behçet's disease in Turkish patients. Clinical data on gender, ABO, and Rhesus blood type of patients with BD were collected at the Kayseri Education and Research Hospital from 2005 to 2012. A total of 115 patients with BD were assessed for their association with ABO or Rhesus (D) blood groups and compared with the distribution of the blood groups of 25,701 healthy donors admitted to the Kayseri Education and Research Hospital Blood Center in 2010 and 2011. The distribution of ABO and Rhesus blood groups in patients with BD was similar to the healthy donors. No relationship was found between ABO or Rhesus blood groups and BD at our hospital. Further studies with a larger series and in different centers may be valuable for identifying the association between ABO or Rhesus (D) blood groups and BD.

  15. Effects of Topical Phenylephrine HCl 2.5% used before Cataract Surgery on Systemic Blood Pressure

    Directory of Open Access Journals (Sweden)

    Emre Ayıntap

    2011-06-01

    Full Text Available Purpose: To evaluate the effect of topical phenylephrine HCl 2.5% (Mydfrin, used as a fast and effective mydriatic before cataract surgery, on systemic blood pressure. Material and Method: Topical phenylephrine HCl 2.5% was administered 3 times with 5-minute intervals before cataract surgery to 44 eyes of 44 patients. The systemic blood pressure was measured preoperatively and at 15 and 30 minutes. Results: The mean systolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 119.7mmHg, while 15 and 30 minutes later, it was 125.3 mmHg and 121.2 mmHg, respectively. The mean diastolic blood pressure before the topical administration of phenylephrine HCl 2.5% was 75.9 mmHg; 15 and 30 minutes later, it was 76.9 mmHg and 75.3 mmHg, respectively. The increase in systolic blood pressure at 15 and 30 minutes was statistically significant (p=0.003 and p=0.042. The change in diastolic blood pressure was not statistically significant. Discussion: Phenylephrine HCl 2.5%, which is used preoperatively as a fast and effective mydriatic for cataract surgery, can increase the systolic blood pressure. This effect is most significant at 15 minutes and lasts at least 30 minutes. This agent should be used with care in hypertensive patients. (Turk J Ophthalmol 2011; 41: 164-6

  16. Energetics and sugar-feeding of field-collected anopheline females.

    Science.gov (United States)

    Holliday-Hanson, M L; Yuval, B; Washino, R K

    1997-06-01

    We studied the relationship between nutritional reserves and blood-feeding and sugar-feeding of Anopheles freeborni (Diptera: Culicidae) females in the field. In particular we determined whether (1) females feed on nectar before maturing eggs and initiating host-seeking and (2) the energy reserves of host-seeking females differ from those of non-fed resting females. Twenty-three percent of host-seeking females and 94 percent of gravid females were positive for nectar sugars (containing > 20 micrograms of fructose) versus 55 percent of empty (no blood or eggs) females collected in the morning and 36 percent of empty females collected in the evening. In addition, gravid females contained significantly more calories of nectar than empty, blood-fed, or partially blood-fed females collected in the morning. When the energy reserves of host-seeking and resting females were compared, no differences were found in lipid, trehalose, or glycogen. However, empty females collected in the evening contained more glycogen than empty females collected in the morning. We conclude that gravid females frequently feed on nectar and that fructose is metabolized into glycogen during the day.

  17. Distribution of abo, rhesus blood groups and haemoglobin ...

    African Journals Online (AJOL)

    Summary: The distribution of ABO, Rhesus blood groups and haemoglobin electrophoresis among 200 undergraduate students of Niger Delta University, Bayelsa State, Nigeria randomly selected were studied. Blood samples were collected by venepuncture from the antecubital vein. The blood sample were transferred into ...

  18. Effect of laser on human blood

    International Nuclear Information System (INIS)

    Abdalsamad, Amuna Nagash Mohammed

    2016-03-01

    In this work, the effect of He-Ne (632.8 nm), N2 (337.1 nm), LED (450 nm) on the human blood, and blood component was studied by using CBC machine ( complete blood count) and UV -visible spectroscopy. Blood samples platoon A+ were collected and irradiated for different periods of time (10 minute, 20 minute, and 30 minute), to varied types of light source ( He- Ne laser and LED). Blood parameters of samples were measured by using complete Blood Count Machine (CBC). The absorption spectrum of blood samples were examined by using UV-visible spectrometer. The obtained results have shown different values of Complete Blood Counts and absorption spectrum due to different laser types and periods of time. We conclude that the laser light has clear effect on blood samples. (Author)

  19. System for Anonymous Data Collection Based on Group Signature Scheme

    Directory of Open Access Journals (Sweden)

    David Troják

    2016-01-01

    Full Text Available This paper deals with an anonymous data collection in the Internet of Things (IoT. the privacy and anonymity of the data source is important for many IoT applications, such as in agriculture, health, and automotive. the proposed data‑collection system provides anonymity for the data sources by applying a cooperation group scheme. the group scheme also provides a low power consumption. the system is built upon the Tor (The Onion Router anonymous network, which is a part of the Internet darknet. the proposed system was designed for the Android devices on the client side and for Java environment on the server side. We evaluated the anonymous data collection in a real‑use scenario that covers selected data acquisition (e.g. signal strength from smartphones triggered by their geographical location change. the results show that the proposed system provides the sufficient data source anonymity, an effective revocation, a low computational cost and a low overhead.

  20. Association of air pollution sources and aldehydes with biomarkers of blood coagulation, pulmonary inflammation, and systemic oxidative stress.

    Science.gov (United States)

    Altemose, Brent; Robson, Mark G; Kipen, Howard M; Ohman Strickland, Pamela; Meng, Qingyu; Gong, Jicheng; Huang, Wei; Wang, Guangfa; Rich, David Q; Zhu, Tong; Zhang, Junfeng

    2017-05-01

    Using data collected before, during, and after the 2008 Summer Olympic Games in Beijing, this study examines associations between biomarkers of blood coagulation (vWF, sCD62P and sCD40L), pulmonary inflammation (EBC pH, EBC nitrite, and eNO), and systemic oxidative stress (urinary 8-OHdG) with sources of air pollution identified utilizing principal component analysis and with concentrations of three aldehydes of health concern. Associations between the biomarkers and the air pollution source types and aldehydes were examined using a linear mixed effects model, regressing through seven lag days and controlling for ambient temperature, relative humidity, gender, and day of week for the biomarker measurements. The biomarkers for pulmonary inflammation, particularly EBC pH and eNO, were most consistently associated with vehicle and industrial combustion, oil combustion, and vegetative burning. The biomarkers for blood coagulation, particularly vWF and sCD62p, were most consistently associated with oil combustion. Systemic oxidative stress biomarker (8-OHdG) was most consistently associated with vehicle and industrial combustion. The associations of the biomarkers were generally not significant or consistent with secondary formation of pollutants and with the aldehydes. The findings support policies to control anthropogenic pollution sources rather than natural soil or road dust from a cardio-respiratory health standpoint.

  1. Determine the prevalence of Brucella spp. and Leptospira spp. in blood samples by multiplex polymerase chain reaction collected from cattle, sheep and goats in herds located in provinces of Iran

    OpenAIRE

    Faham Khamesipour; Shahin Nejat Dehkordi; Taghi Taktaz Hafshejani; Elahe Tajbakhsh; Shahrzad Azizi

    2014-01-01

    Leptospirosis and brucellosis are common zoonosis that affect many species of mammals mostly causing economical losses. Further, very important fact is huge danger for human and animal health around the world. The purpose of the study is to determine the prevalence of Brucella spp. and Leptospira spp. using multiplex polymerase chain reaction (mPCR) method, in blood samples collected from cattle, sheep and goats. In this study, a total number of 250 blood samples (5 cc of blood with ethilen d...

  2. Collection, processing and testing of bone, corneas, umbilical cord blood and haematopoietic stem cells by European Blood Alliance members

    DEFF Research Database (Denmark)

    Närhi, M; Natri, O; Desbois, I

    2013-01-01

    A questionnaire study was carried out in collaboration with the European Blood Alliance (EBA) Tissues and Cells (T&C) working group. The aim was to assess the level of involvement and commonality of processes on the procurement, testing and storage of bone, corneas, umbilical cord blood (UCB......) and haematopoietic stem cells (HSC) in order to identify different practices and to explore whether recommendations can be made for harmonization....

  3. Current concepts in blood glucose monitoring.

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-12-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  4. Current concepts in blood glucose monitoring

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827

  5. Current concepts in blood glucose monitoring

    Directory of Open Access Journals (Sweden)

    Kranti Shreesh Khadilkar

    2013-01-01

    Full Text Available Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG and continuous glucose monitoring system (CGMS. It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  6. Portable linear-focused solar thermal energy collecting system

    Science.gov (United States)

    Miller, C. G.; Pohl, J. G. (Inventor)

    1977-01-01

    A solar heat collection system is provided by utilizing a line-focusing device that is effectively a cylindrically curved concentrator within a protected environment formed by a transparent inflatable casing. A target, such as a fluid or gas carrying conduit is positioned within or near the casing containing the concentrator, at the line focus of the concentrator. The casing can be inflated at the site of use by a low pressure air supply to form a unitary light weight structure. The collector, including casing, concentrator and target, is readily transportable and can be used either at ground level or on rooftops. The inflatable concentrator can be replaced with a rigid metal or other concentrator while maintaining the novel advantages of the whole solar heat collection system.

  7. Stem cell collection in unmanipulated HLA-haploidentical/mismatched related transplantation with combined granulocyte-colony stimulating factor-mobilised blood and bone marrow for patients with haematologic malignancies: the impact of donor characteristics and procedural settings.

    Science.gov (United States)

    Zhang, C; Chen, X-H; Zhang, X; Gao, L; Gao, L; Kong, P-Y; Peng, X-G; Sun, A-H; Gong, Y; Zeng, D-F; Wang, Q-Y

    2010-06-01

    Unmanipulated haploidentical/mismatched related transplantation with combined granulocyte-colony stimulating factor-mobilised peripheral blood stem cells (G-PBSCs) and granulocyte-colony stimulating factor-mobilised bone marrow (G-BM) has been developed as an alternative transplantation strategy for patients with haematologic malignancies. However, little information is available about the factors predicting the outcome of peripheral blood stem cell (PBSC) collection and bone marrow (BM) harvest in this transplantation. The effects of donor characteristics and procedure factors on CD34(+) cell yield were investigated. A total of 104 related healthy donors received granulocyte-colony stimulating factor (G-CSF) followed by PBSC collection and BM harvest. Male donors had significantly higher yields compared with female donors. In multiple regression analysis for peripheral blood collection, age and flow rate were negatively correlated with cell yield, whereas body mass index, pre-aphaeresis white blood cell (WBC) and circulating immature cell (CIC) counts were positively correlated with cell yields. For BM harvest, age was negatively correlated with cell yields, whereas pre-BM collection CIC counts were positively correlated with cell yield. All donors achieved the final product of >or=6 x10(6) kg(-1) recipient body weight. This transplantation strategy has been shown to be a feasible approach with acceptable outcomes in stem cell collection for patients who received HLA-haploidentical/mismatched transplantation with combined G-PBSCs and G-BM. In donors with multiple high-risk characteristics for poor aphaeresis CD34(+) cell yield, BM was an alternative source.

  8. Prenatal typing of Rh and Kell blood group system antigens: The edge of a watershed

    NARCIS (Netherlands)

    van der Schoot, C. Ellen; Tax, G. H. Martine; Rijnders, Robbert J. P.; de Haas, Masja; Christiaens, Godelieve C. M. L.

    2003-01-01

    Knowledge of the molecular basis of the blood group systems has enabled the development of assays for blood group genotyping. At this time, polymerase chain reaction (PCR)-based assays validated on fetal material obtained by invasive means (chorionic villus sampling or amniocentesis) are available

  9. The diagnostic utility of stabilized blood for detection of foot-and-mouth disease virus RNA by RT-qPCR

    DEFF Research Database (Denmark)

    S. Fontél, Kristina; Bøtner, Anette; Belsham, Graham

    In Europe, clinical signs indicative of foot-and-mouth disease (FMD), would immediately lead to collection of blood and relevant organ material for further laboratory examination for this vesicular disease virus. Today, the first line system for detection of virus in the sample material is real t...... time RT-PCR (RT-qPCR). The aim of this study was to investigate the diagnostic utility of stabilized blood for detection of FMDV RNA in this system....

  10. Nosocomial epidemic of Serratia marcescens septicemia ascribed to contaminated blood transfusion bags

    DEFF Research Database (Denmark)

    Heltberg, Ole; Skov, F; Gerner-Smidt, P

    1993-01-01

    isolates was performed. For comparison, a strain from the production plant and eight other, unrelated bacteremia isolates were examined. In addition, a retrospective national survey was carried out. S. marcescens was cultured from 11 (0.73%) of 1515 blood units, and an additional (third) bacteremic patient...... was identified. The clinical isolates from three patients, the three units of blood transfused, and the plant-derived strain shared a unique ribotype. The incident is interpreted as a sporadic, bacterial contamination of blood bags with the S. marcescens epidemic strain, occurring during the manufacturing...... or packaging. A similar incident has not previously been reported. Attention is drawn to the possibility of significant contamination during the complex production of multiple-bag blood collection systems. Guidelines for improved registration and handling of transfusion complications in wards are suggested...

  11. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system.

    Science.gov (United States)

    Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F

    2011-01-01

    Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  12. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.

    1981-06-01

    The working conditions of a new on-line electrostatic collection system are presented. The main charactersitics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given

  13. Automated processing of whole blood units: operational value and in vitro quality of final blood components.

    Science.gov (United States)

    Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz

    2012-01-01

    The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement.

  14. Haematological changes in the blood of cultured Clarias gariepinus ...

    African Journals Online (AJOL)

    This study investigated the artifactual changes in the haematological values of Clarias gariepinus blood stored at room (32oC) and refrigerator (4oC) temperatures. Blood samples were collected from 12 apparently healthy fish weighing between 0.8 and 1kg. Samples were divided into two parts immediately after collection ...

  15. Tumor blood flow and systemic shunting in patients receiving intraarterial chemotherapy for head and neck cancer

    International Nuclear Information System (INIS)

    Wheeler, R.H.; Ziessman, H.A.; Medvec, B.R.; Juni, J.E.; Thrall, J.H.; Keyes, J.W.; Pitt, S.R.; Baker, S.R.

    1986-01-01

    Radionuclide techniques have been used to estimate the systemic shunt and to quantitate blood flow to the tumor and a reference normal tissue in nine patients undergoing intraarterial chemotherapy for head and neck cancer. The systemic shunt was calculated as the percentage of pulmonary trapping of intraarterially injected /sup 99m/Tc-labeled macroaggregated albumin. The mean systemic shunt in the 12 separate arteries studied was 23 +/- 13% (SE) (range 8-43%). Quantitative blood flow was determined from the slope of the washout curve of intraarterially injected 133 Xe. The mean tumor blood flow was 13.6 +/- 6.7 ml/100 g/min, while the mean blood flow to the scalp was 4.2 +/- 2.1 ml/100 g/min providing a mean tumor/normal tissue ratio of 3.9 +/- 2.7. An estimate of blood flow distribution was obtained by calculating the ratio of counts/pixel in the tumor mass versus the remainder of the head as determined by single photon emission computed tomography following an intraarterial injection of /sup 99m/Tc-labeled macroaggregated albumin. The mean ratio of tumor to normal tissue perfusion by this technique was 5.6 +/- 3.7. These techniques have allowed noninvasive determination of the blood flow parameters associated with intraarterial chemotherapy. At least part of the therapeutic advantage of regional chemotherapy in patients with head and neck cancer is due to a tumor/normal tissue blood flow ratio that favors drug delivery to the tumor contained within the infused volume

  16. Determine The Factors Affecting The Blood Donors Of Selecting Blood Donor Program Me In Western Province Sri Lanka

    Directory of Open Access Journals (Sweden)

    Perera D. A. K.

    2015-08-01

    Full Text Available Abstract Blood and blood component transfusion is one of the major therapeutic practices throughout the world. National Blood Transfusion Service NBTS in Sri Lanka requires approximately 300000 blood units annually. After initiating mobile donor programme there have been two types of blood donation programs in Sri Lanka since 1980. Since second half of first decade of 21st century Sri Lanka shifted to 100 non-replacement blood transfusion policy. That means whole blood and blood component requirement of NBTS has to be collected through mobile blood donor program and voluntary In-house blood donor program. Therefore the objective of this study was to determine the factors affecting the blood donors of selecting blood donor program in Western province Sri Lanka. Methodology This was a cross sectional descriptive study. The study composed of two components. .First the factors that cause the blood donor to select a blood donor programme second the facility survey of blood banks In-house donation. An interviewer administered questionnaire was used to collect data from a sample of 410 Mobile blood donors. Facility survey was done using a checklist. The dependant variables were the attendance of the blood donors to Mobile blood donation and In-house blood donation. Independent variables included were the factors related to socio demography service quality accessibility availability and intrinsic extrinsic motivation. The analytical statistics applied for testing the association of factors with the blood donor programme was chi-square test. The study has shown some important findings. There was significant association between income level and donating blood. Only 3.3 of In-house blood donor population was female. Majority of In-house population belonged to 30-41 age group. A statistically significant association exists between age and repeat blood donation. The female blood donors tendency of becoming repeat donors was very low. Distance problem and non

  17. Alpha-Amylase Activity in Blood Increases after Pharmacological, But Not Psychological, Activation of the Adrenergic System.

    Directory of Open Access Journals (Sweden)

    Urs M Nater

    Full Text Available Alpha-amylase in both blood and saliva has been used as a diagnostic parameter. While studies examining alpha-amylase activity in saliva have shown that it is sensitive to physiological and psychological challenge of the adrenergic system, no challenge studies have attempted to elucidate the role of the adrenergic system in alpha-amylase activity in blood. We set out to examine the impact of psychological and pharmacological challenge on alpha-amylase in blood in two separate studies.In study 1, healthy subjects were examined in a placebo-controlled, double-blind paradigm using yohimbine, an alpha2-adrenergic antagonist. In study 2, subjects were examined in a standardized rest-controlled psychosocial stress protocol. Alpha-amylase activity in blood was repeatedly measured in both studies.Results of study 1 showed that alpha-amylase in blood is subject to stronger increases after injection of yohimbine compared to placebo. In study 2, results showed that there was no significant effect of psychological stress compared to rest.Alpha-amylase in blood increases after pharmacological activation of the adrenergic pathways suggesting that sympathetic receptors are responsible for these changes. Psychological stress, however, does not seem to have an impact on alpha-amylase in blood. Our findings provide insight into the mechanisms underlying activity changes in alpha-amylase in blood in healthy individuals.

  18. Optimization of sugar and blood feeding regimen in Anopheles gambiae mass production system

    International Nuclear Information System (INIS)

    Sedofia, B. K

    2013-07-01

    The sterile insect technique (SIT) is being developed for the control of malaria transmitting mosquitoes. Critical to the success of applying the SIT is the establishment of standardized mass production systems for the target species. As part of efforts to develop standardised mass production systems for malaria vectors, this project sought to optimize adult blood and sugar feeding in a mass production system. Different sugar types (glucose, sucrose and honey) were evaluated at 6% and 10% concentrations in water to determine the best sugar diet and concentration for feeding adult An. gambiae. Different blood feeding methods, restrained Guinea pig, anaesthetised Guinea pig and human arm feeding were evaluated. Adult survival, female insemination and egg production were used as criteria to determine optimum sugar and blood feeding. The effect of anaesthetics on blood feeding response and egg production of female An. gambiae was determined by comparing feeding response and egg production of females fed with anaesthetised Guinea pigs as against physically restrained Guinea pigs (Control). The specific effect of different anaesthetic agents on blood feeding response and egg production of female mosquitoes were was also determined by comparing the feeding response and egg production of females fed with either Ketamine/Xylazine anaesthetised Guinea pigs or Ketamine/Diazepam anaesthetised Guinea pigs. Effects due to sugar types and concentrations on percentage survival of male and female mosquitoes were observed to be significant at (p 0.05). However, human ann feeding (HAP) method and Ketamine/Xylazine (KX) anaesthetics fed for 25 minutes recorded higher percentage feeding (76.0% and 68.0% respectively) and egg production of 19.0% and 20.8% respectively. Anaesthetised Guinea pig feeding (AGF) of adults for 15 minutes followed closely with 60.0% and 15.1% blood feeding and egg production respectively whilst restrained Guinea pig feeding (RGF) method and Ketamine

  19. Multidisciplinary team review of best practices for collection and handling of blood cultures to determine effective interventions for increasing the yield of true-positive bacteremias, reducing contamination, and eliminating false-positive central line-associated bloodstream infections.

    Science.gov (United States)

    Garcia, Robert A; Spitzer, Eric D; Beaudry, Josephine; Beck, Cindy; Diblasi, Regina; Gilleeny-Blabac, Michelle; Haugaard, Carol; Heuschneider, Stacy; Kranz, Barbara P; McLean, Karen; Morales, Katherine L; Owens, Susan; Paciella, Mary E; Torregrosa, Edwin

    2015-11-01

    A literature search was conducted using keywords for articles published in English from January 1990 to March 2015. Using criteria related to blood culture collection and handling, the search yielded 101 articles. References used also included Microbiology Laboratory standards, guidelines, and textbook information. The literature identified diverse and complex issues surrounding blood culture practices, including the impact of false-positive results, laboratory definition of contamination, effect on central line-associated bloodstream infection (CLABSI) reporting, indications for collecting blood cultures, drawing from venipuncture sites versus intravascular catheters, selection of antiseptics, use of needleless connectors, inoculation of blood culture bottles, and optimizing program management in emergency departments, education, and implementation of bundled practice initiatives. Hospitals should optimize best practice in the collection, handling, and management of blood culture specimens, an often overlooked but essential component in providing optimal care of patients in all settings and populations, reducing financial burdens, and increasing the accuracy of reportable CLABSI. Although universal concepts exist in blood culture practices, some issues require further research to determine benefit. Institutions undertaking a review of their blood culture programs are encouraged to use a checklist that addresses elements that encompass the research contained in this review. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Microbial contamination of the Tzu-Chi Cord Blood Bank from 2005 to 2006.

    Science.gov (United States)

    Chen, Shu-Huey; Zheng, Ya-Jun; Yang, Shang-Hsien; Yang, Kuo-Liang; Shyr, Ming-Hwang; Ho, Yu-Huai

    2008-01-01

    In total, 4502 units of cord blood (CB) were collected during a 2-year period from 2005 to 2006 by the Buddhist Tzu-Chi Stem Cells Center. The aim of this study was to analyze the incidence of microbial contamination and type of organism present in the cord blood. The clinical impact of microbial contamination on hematopoietic progenitor cell (HPC) grafts used for HPC transplantation is also discussed. First and second specimens were obtained for microbial assessment. These were collected in laboratory after cord blood collection and after cord blood unit manipulation, respectively. The samples were cultured and the results reviewed. The overall incidence of microbiological contamination was 1.8% (82/4502). Three CB units were contaminated with two different organisms. Infectious organisms comprised 9.4% (8/85) of total isolated microbes. These infectious microorganisms were beta-Streptococci group B, Candida tropicalis and Staphylococcus aureus which were isolated in 6, 1 and 1 of CB units respectively. Escherichia coli, Bacteroides fragilis, Lactobacillus spp., Enterococcus, beta-Streptococcus Group B, Bacteroides valgatus, Corynebacterium spp., Klebsiella pneumonia and Peptococcus spp. were the most frequently encountered microorganisms. A higher contamination rate of the CB units was noted after vaginal delivery (2.16%) compared to caesarian section (0.85%) (p bank, we use a closed system but an in utero method. Similar to other studies, most of microorganisms reported here as contaminants are non-pathogenic.

  1. Current concepts in blood glucose monitoring

    OpenAIRE

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on t...

  2. The great East Japan earthquake of March 11, 2011, from the vantage point of blood banking and transfusion medicine.

    Science.gov (United States)

    Nollet, Kenneth E; Ohto, Hitoshi; Yasuda, Hiroyasu; Hasegawa, Arifumi

    2013-01-01

    The Great East Japan Earthquake of March 11, 2011, and subsequent tsunami took nearly 20 000 lives in Tohoku, the northeastern part of Japan's main island. Most victims were either carried away by the tsunami or drowned. The ability to collect blood was disrupted on the Pacific coast of Tohoku. Inland areas were less affected, but allogeneic blood collected in Tohoku is tested at the Miyagi Red Cross Blood Center (Miyagi Center) in the coastal city of Sendai. Miyagi Center was damaged and could not test for 2 months. The aims of this study are as follows: (1) to assess transfusion practice at 8 disaster response hospitals in Tohoku's Fukushima Prefecture, for equal intervals before and after March 11, 2011; (2) to report activities related to blood collection and distribution in response to the disaster; and (3) to describe the Great East Japan Earthquake in the context of other disasters. Data were collected through a survey of transfusion services at 8 major disaster response hospitals, communication at transfusion conferences, and literature review. Transfused patients and units transfused were about 70% and 60% of normal in the surveyed hospitals because this was a disaster of mass casualty rather than mass injury, and patients requiring chronic care were evacuated out. A nationally coordinated effort allowed excess blood collected outside Tohoku to be transported in, despite infrastructure damage. Japan's national system of blood collection and distribution responded effectively to local needs after the Great East Japan Earthquake. Disasters such as Japan's 3.11 should guide discourse about emergency preparedness and centralization of services. Copyright © 2013. Published by Elsevier Inc.

  3. Increased occupational coal dust toxicity in blood of central heating system workers.

    Science.gov (United States)

    Tuluce, Yasin; Ozkol, Halil; Koyuncu, Ismail; Ine, Hatice

    2011-02-01

    Coal dust causes lung diseases in occupational exposure. Reactive oxygen species have been implicated in the pathogenesis of its toxicity. In this study, serum enzymes, lipid profile and other biochemical values with oxidant/antioxidant status in whole blood and serum of central heating system workers (CHSW; the persons responsible for heating the apartment with coal) were determined to reflect the cell injury. Blood samples were obtained from CHSW (n = 25) and healthy individuals (n = 25). All values were measured in whole blood and serum. ANOVA was used for the estimation of statistical data. In the group of CHSW, creatinine, ferritin, alanin aminotransferase, aspartate aminotransferase, creatine phosphokinase, gamma glutamyl transferase, lactate dehydrogenase and glutathione reductase activities as well as triglyceride, very low density lipoprotein, protein carbonyl and malondialdehide were significantly higher, while transferrin, high density lipoprotein and catalase (CAT) activities were lower than the group of healthy individuals. This result is consistent with hypothesis that respirable coal dust generates lipid and protein oxidation and induces leakage of serum enzymes by cell damage. It also leads to imbalance in antioxidant defense system, lipid profile and other biochemical parameters.

  4. The meanings of consent to the donation of cord blood stem cells: perspectives from an interview-based study of a public cord blood bank in England

    OpenAIRE

    Busby, Helen

    2010-01-01

    This paper explores the perspectives of women who have agreed that their umbilical cord blood may be collected for a public ‘cord blood bank’, for use in transplant medicine or research. Drawing on interview data from 27 mothers who agreed to the collection and use of their umbilical cord blood, these choices and the informed consent process are explored. It is shown that the needs of sick children requiring transplants are prominent in narrative accounts of cord blood banking, together with ...

  5. Mouse preantral follicle growth in 3D co-culture system using human menstrual blood mesenchymal stem cell.

    Science.gov (United States)

    Rajabi, Zahra; Yazdekhasti, Hossein; Noori Mugahi, Seyed Mohammad Hossein; Abbasi, Mehdi; Kazemnejad, Somaieh; Shirazi, Abolfazl; Majidi, Masoumeh; Zarnani, Amir-Hassan

    2018-03-01

    Follicle culture provides a condition which can help investigators to evaluate various aspects of ovarian follicle growth and development and impact of different components and supplementations as well as presumably application of follicle culture approach in fertility preservation procedures. Mesenchymal Stem Cells (MSCs), particularly those isolated from menstrual blood has the potential to be used as a tool for improvement of fertility. In the current study, a 3D co-culture system with mice preantral follicles and human Menstrual Blood Mesenchymal Stem Cells (MenSCs) using either collagen or alginate beads was designed to investigate whether this system allows better preantral follicles growth and development. Results showed that MenSCs increase the indices of follicular growth including survival rate, diameter, and antrum formation as well as the rate of in vitro maturation (IVM) in both collagen and alginates beads. Although statistically not significant, alginate was found to be superior in terms of supporting survival rate and antrum formation. Hormone assay demonstrated that the amount of secreted 17 β-estradiol and progesterone in both 3D systems increased dramatically after 12 days, with the highest levels in system employing MenSCs. Data also demonstrated that relative expression of studied genes increased for Bmp15 and Gdf9 and decreased for Mater when follicles were cultured in the presence of MenSCs. Collectively, results of the present study showed that MenSCs could improve indices of follicular growth and maturation in vitro. Further studies are needed before a clinical application of MenSCs-induced IVM is considered. Copyright © 2018 Society for Biology of Reproduction & the Institute of Animal Reproduction and Food Research of Polish Academy of Sciences in Olsztyn. All rights reserved.

  6. An experimental system for the study of ultrasound exposure of isolated blood vessels

    NARCIS (Netherlands)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and

  7. Acute Blood Loss During Burn and Soft Tissue Excisions: An Observational Study of Blood Product Resuscitation Practices and Focused Review

    Science.gov (United States)

    2015-06-24

    prospective observational study. Number, component type , volume, and age of the blood products transfused were recorded during burn excision/grafting or soft...tissue debridement . Component bags (packed red blood cells, fresh frozen plasma, platelets, and cryoprecipitate) were collected, and the remaining...collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 24 JUN 2015 2. REPORT TYPE N/A 3. DATES

  8. A new electrostatic on-line collection-system

    International Nuclear Information System (INIS)

    Dufour, J.P.; Del Moral, R.; Fleury, A.; Hubert, F.; Llabador, Y.; Mauhourat, M.B.; Bimbot, R.; Gardes, D.; Rivet, M.F.

    1981-01-01

    The working conditions of a new on-line electrostatic collection system are presented. The main characteristics are high efficiency (reaching 20%) and short delay time (down to the millisecond). The salient features of specific devices for measurements of absolute cross sections, recoil range distributions and angular distributions are given. (orig.)

  9. Blood Transfusion (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Transfusions KidsHealth / For Parents / Blood Transfusions What's in this ... and help put your child at ease. About Blood Transfusions Blood is like the body's transportation system. As ...

  10. 76 FR 8349 - Proposed Collection; Comment Request

    Science.gov (United States)

    2011-02-14

    ... System (DBMS) and Blood Transfusion Management System (BTMS) with capabilities to manage blood donors... a comprehensive enterprise wide Blood Donor Management System (DBMS) and Blood Transfusion...

  11. Unfolding epidemiological stories: how the WHO made frozen blood into a flexible resource for the future.

    Science.gov (United States)

    Radin, Joanna

    2014-09-01

    In the decades after World War II, the World Health Organization (WHO) played an important role in managing the process of stabilizing collections of variable blood samples as a fundamentally unstable, protean, and unfolding biomedical resource. In this system, known and as yet unknown constituents of blood were positioned as relevant to the work of multiple constituencies including human population geneticists, physical anthropologists, and immunologists. To facilitate serving these and other constituencies, it was crucial to standardize practices of collecting and preserving samples of blood from globally distributed human populations. The WHO achieved this by linking its administrative infrastructure-comprised of expert advisory groups and technical reports-to key laboratories, which served as sites for demonstrating and also for disseminating standards for working with variable blood samples. The practices that were articulated in making blood samples into a flexible resource contributes to emerging histories of global health that highlight the centrality of new institutions, like the WHO, new forms of expertise, like population genetics and serological epidemiology, and new kinds of research materials, like frozen blood. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. 78 FR 79455 - Information Collection; System for Award Management Registration Requirements for Prime Grant...

    Science.gov (United States)

    2013-12-30

    ...] Information Collection; System for Award Management Registration Requirements for Prime Grant Recipients.... ADDRESSES: Submit comments identified by Information Collection 3090- 0290, System for Award Management... ``Information Collection 3090-0290, System for Award Management Registration Requirements for Prime Grant...

  13. Effect of humic-plant feed preparations on biochemical blood parameters of laying hens in deep litter housing system.

    Science.gov (United States)

    Bubel, F; Dobrzański, Z; Gaweł, A; Pogoda-Sewerniak, K; Grela, E R

    2015-01-01

    An influence of various humic-plant feed additives based on some herbs (nettle, chamomile, yarrow, perforatum), lucerne and humic materials on biochemical indices of Lohmann Brown (LB) layers blood plasma was estimated. Hens were housed in deep litter system, 20 birds in a group. Four groups were formed: control (C - standard feeding), and experimental, supplemented with prepara- tions: E-1 herbal-humic, E-2 humic-herbal and E-3--humic-lucerne. Hens were placed in the pens on the 16th week of life, addition of preparations with standard food mixture started at the 22nd wk and lasted until 66th wk of life. Blood for analyses was collected four times in the following periods: 27, 37, 54 and 65th wk of life. The applied humic-plant preparations to a limited degree affected the values of examined biochemical parameters in serum: total protein (TP), albumins (Albs), glucose (Glu), urea, triacylglycerols (TAG), total cholesterol (TCh), alanine aminotransferase (ALT), aspartate aminot- ransferase (AST) and alkaline phosphatase (ALP). It is difficult to determine based on these study, which preparation is one the most active biologically, however is seems that humic-lucerne prepara- tion affected the examined blood parameters to the highest degree. The reference values ranges in hens blood serum LB hens were proposed for: TP (43-65 g/l), Albs (15-22 g/l), urea (0.5-1.2 mmol/l), Glu 10-15 mmol/l), TCh (2.2-4.5 mmol/l), TAG (10-24 mmol/l), AST (4-12 U/l), ALT (150-280 mmol/l) and ALP (190-350 U/l).

  14. Assessing ABO/Rh Blood Group Frequency and Association with Asymptomatic Malaria among Blood Donors Attending Arba Minch Blood Bank, South Ethiopia

    Directory of Open Access Journals (Sweden)

    Getaneh Alemu

    2016-01-01

    Full Text Available Background. Determination of the various ABO/Rh blood group distributions and their association with malaria infection has paramount importance in the context of transfusion medicine and malaria control. Methods. Facility based cross-sectional study was conducted from February to June, 2015, to assess ABO/Rh blood groups distribution and their association with asymptomatic malaria. A structured questionnaire was used to collect data. Blood grouping was done using monoclonal antibodies. Thin and thick blood films were examined for Plasmodium parasites. Data were analyzed using SPSS version 20.0. Results. A total of 416 blood donors participated with median age of 22±0.29 (median ± standard error of the mean. Distribution of ABO phenotypes, in decreasing order, was O (175, 42.1%, A (136, 32.7%, B (87, 20.9%, and AB (18, 4.3%. Most of them were Rh+ (386, 92.8%. The overall malaria prevalence was 4.1% (17/416. ABO blood group is significantly associated with malaria infection (P=0.022. High rate of parasitemia was seen in blood group O donors (6.899, P=0.003 compared to those with other ABO blood groups. Conclusion. Blood groups O and AB phenotypes are the most and the least ABO blood groups, respectively. There is significant association between ABO blood group and asymptomatic malaria parasitemia.

  15. Assessment of a continuous blood gas monitoring system in animals during circulatory stress

    Directory of Open Access Journals (Sweden)

    Renzulli Attilio

    2011-01-01

    Full Text Available Abstract Background The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min, vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h, hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia, and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg.Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed. Results Bias and precision for pO2 were - 0.06 kPa and 0.22 kPa, respectively (r2 = 0.96; pCO2 - 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r2 = 0.96. The analysis showed very good agreement for SO2 (bias 0.04,precision 0.33, r2 = 0.95, Base excess (bias 0.04,precision 0.28, r2 = 0.98, HCO3 (bias 0.05,precision 0.62, r2 = 0.92,hemoglobin (bias 0.02,precision 0.23, r2 = 0.96 and K+ (bias 0.02, precision 0.27, r2 = 0.93. The sensor was reliable throughout the experiment during hemodynamic variations. Conclusions Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.

  16. Proposed Application of Fast Fourier Transform in Near Infra Red Based Non Invasive Blood Glucose Monitoring System

    Science.gov (United States)

    Jenie, R. P.; Iskandar, J.; Kurniawan, A.; Rustami, E.; Syafutra, H.; Nurdin, N. M.; Handoyo, T.; Prabowo, J.; Febryarto, R.; Rahayu, M. S. K.; Damayanthi, E.; Rimbawan; Sukandar, D.; Suryana, Y.; Irzaman; Alatas, H.

    2017-03-01

    Worldwide emergence of glycaemic status related health disorders, such as diabetes and metabolic syndrome, is growing in alarming rate. The objective was to propose new methods for non invasive blood glucose level measurement system, based on implementation of Fast Fourier Transform methods. This was an initial-lab-scale-research. Data on non invasive blood glucose measurement are referred from Scopus, Medline, and Google Scholar, from 2011 until 2016, and was used as design references, combined with in house verification. System was developed in modular fashion, based on aforementioned compiled references. Several preliminary tests to understand relationship between LED and photo-diode responses have been done. Several references were used as non invasive blood glucose measurement tools design basis. Solution is developed in modular fashion. we have proven different sensor responses to water and glucose. Human test for non invasive blood glucose level measurement system is needed.

  17. Tainted blood

    DEFF Research Database (Denmark)

    Deleuran, Ida; Sheikh, Zainab Afshan; Hoeyer, Klaus

    2015-01-01

    The existing literature on donor screening in transfusion medicine tends to distinguish between social concerns about discrimination and medical concerns about safety. In this article, we argue that the bifurcation into social and medical concerns is problematic. We build our case on a qualitative...... study of the historical rise and current workings of safety practices in the Danish blood system. Here, we identify a strong focus on contamination in order to avoid 'tainted blood', at the expense of working with risks that could be avoided through enhanced blood monitoring practices. Of further...... significance to this focus are the social dynamics found at the heart of safety practices aimed at avoiding contamination. We argue that such dynamics need more attention, in order to achieve good health outcomes in transfusion medicine. Thus, we conclude that, to ensure continuously safe blood systems, we...

  18. Interactive handling of regional cerebral blood flow data using a macrolanguage

    International Nuclear Information System (INIS)

    Sveinsdottir, E.; Schomacker, T.; Lassen, N.A.

    1976-01-01

    A general image handling software system has been developed for on-line collection, processing and display of gamma camera images (IMAGE system). The most distinguishable feature of the system is the ability for the user to interactively specify sequences, called macros, of basic functions to be performed. Information about a specified sequence is retained in the system, thus enabling new sequences or macros to be defined using already specified sequences. Facilities for parameter setting and parameter transfer between functions, as well as facilities for repetition of a function, are included. Finally, functions, be it basic or macro, can be specified to be iteratively activated using a physiological trigger signal as f.ex. the ECG. In addition, a special program system was developed for handling the dynamic data, from Xenon-133 studies of regional cerebral blood flow (CBF system). Parametric or functional images derived from the CBF system and depicting estimates of regional cerebral blood flow, relative weights of grey matter or other parameters can after computation be handled in the IMAGE system

  19. A brief history of human blood groups.

    Science.gov (United States)

    Farhud, Dariush D; Zarif Yeganeh, Marjan

    2013-01-01

    The evolution of human blood groups, without doubt, has a history as old as man himself. There are at least three hypotheses about the emergence and mutation of human blood groups. Global distribution pattern of blood groups depends on various environmental factors, such as disease, climate, altitude, humidity etc. In this survey, the collection of main blood groups ABO and Rh, along with some minor groups, are presented. Several investigations of blood groups from Iran, particularly a large sampling on 291857 individuals from Iran, including the main blood groups ABO and Rh, as well as minor blood groups such as Duffy, Lutheran, Kell, KP, Kidd, and Xg, have been reviewed.

  20. Transaction Costs in Collective Waste Recovery Systems in the EU

    OpenAIRE

    Nozharov, Shteryo

    2018-01-01

    The study aims to identify the institutional flaws of the current EU waste management model by analysing the economic model of extended producer responsibility and collective waste management systems and to create a model for measuring the transaction costs borne by waste recovery organizations. The model was approbated by analysing the Bulgarian collective waste management systems that have been complying with the EU legislation for the last 10 years. The analysis focuses on waste oils becau...

  1. Interpretation of Blood Microbiology Results - Function of the Clinical Microbiologist.

    Science.gov (United States)

    Kristóf, Katalin; Pongrácz, Júlia

    2016-04-01

    The proper use and interpretation of blood microbiology results may be one of the most challenging and one of the most important functions of clinical microbiology laboratories. Effective implementation of this function requires careful consideration of specimen collection and processing, pathogen detection techniques, and prompt and precise reporting of identification and susceptibility results. The responsibility of the treating physician is proper formulation of the analytical request and to provide the laboratory with complete and precise patient information, which are inevitable prerequisites of a proper testing and interpretation. The clinical microbiologist can offer advice concerning the differential diagnosis, sampling techniques and detection methods to facilitate diagnosis. Rapid detection methods are essential, since the sooner a pathogen is detected, the better chance the patient has of getting cured. Besides the gold-standard blood culture technique, microbiologic methods that decrease the time in obtaining a relevant result are more and more utilized today. In the case of certain pathogens, the pathogen can be identified directly from the blood culture bottle after propagation with serological or automated/semi-automated systems or molecular methods or with MALDI-TOF MS (matrix-assisted laser desorption-ionization time of flight mass spectrometry). Molecular biology methods are also suitable for the rapid detection and identification of pathogens from aseptically collected blood samples. Another important duty of the microbiology laboratory is to notify the treating physician immediately about all relevant information if a positive sample is detected. The clinical microbiologist may provide important guidance regarding the clinical significance of blood isolates, since one-third to one-half of blood culture isolates are contaminants or isolates of unknown clinical significance. To fully exploit the benefits of blood culture and other (non- culture

  2. Implementing asyncronous collective operations in a multi-node processing system

    Science.gov (United States)

    Chen, Dong; Eisley, Noel A.; Heidelberger, Philip; Kumar, Sameer; Salapura, Valentina; Steinmacher-Burow, Burkhard

    2014-07-08

    A method, system, and computer program product are disclosed for implementing an asynchronous collective operation in a multi-node data processing system. In one embodiment, the method comprises sending data to a plurality of nodes in the data processing system, broadcasting a remote get to the plurality of nodes, and using this remote get to implement asynchronous collective operations on the data by the plurality of nodes. In one embodiment, each of the nodes performs only one task in the asynchronous operations, and each nodes sets up a base address table with an entry for a base address of a memory buffer associated with said each node. In another embodiment, each of the nodes performs a plurality of tasks in said collective operations, and each task of each node sets up a base address table with an entry for a base address of a memory buffer associated with the task.

  3. Emergency medical technician-performed point-of-care blood analysis using the capillary blood obtained from skin puncture.

    Science.gov (United States)

    Kim, Changsun; Kim, Hansol

    2017-12-09

    Comparing a point-of-care (POC) test using the capillary blood obtained from skin puncture with conventional laboratory tests. In this study, which was conducted at the emergency department of a tertiary care hospital in April-July 2017, 232 patients were enrolled, and three types of blood samples (capillary blood from skin puncture, arterial and venous blood from blood vessel puncture) were simultaneously collected. Each blood sample was analyzed using a POC analyzer (epoc® system, USA), an arterial blood gas analyzer (pHOx®Ultra, Nova biomedical, USA) and venous blood analyzers (AU5800, DxH2401, Beckman Coulter, USA). Twelve parameters were compared between the epoc and reference analyzers, with an equivalence test, Bland-Altman plot analysis and linear regression employed to show the agreement or correlation between the two methods. The pH, HCO 3 , Ca 2+ , Na + , K + , Cl - , glucose, Hb and Hct measured by the epoc were equivalent to the reference values (95% confidence interval of mean difference within the range of the agreement target) with clinically inconsequential mean differences and narrow limits of agreement. All of them, except pH, had clinically acceptable agreements between the two methods (results within target value ≥80%). Of the remaining three parameters (pCO 2, pO 2 and lactate), the epoc pCO 2 and lactate values were highly correlated with the reference device values, whereas pO 2 was not. (pCO 2 : R 2 =0.824, y=-1.411+0.877·x; lactate: R 2 =0.902, y=-0.544+0.966·x; pO 2 : R 2 =0.037, y=61.6+0.431·x). Most parameters, except only pO 2 , measured by the epoc were equivalent to or correlated with those from the reference method. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Some central nervous system and blood pressure lowering effects of ...

    African Journals Online (AJOL)

    The methanol extract of the leaves of Spondias mombin (SP) was evaluated for some central nervous system and blood pressure lowering effect in albino wistar rats and mice. The extract was administered to pre-weighed mice (20-35 g), divided into five groups of five mice each at the doses of 50, 100 and 200 mg/kg for the ...

  5. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... Abstracts Blood Advances A peer-reviewed, online only, open access ... to help stay current with the latest advances in the field Hematology 2017 A collection of articles from the ...

  6. Clinical, haematological and biochemical responses of sheep undergoing autologous blood transfusion

    Directory of Open Access Journals (Sweden)

    Sousa Rejane

    2012-05-01

    Full Text Available Abstract Background This study aimed to evaluate the clinical, haematological and biochemical responses to autologous blood transfusion and the feasibility of this practice in sheep. Thus, we used eight male, 8 months old sheep, weighing on average 30 kg, from which 15 mL/kg of whole blood was collected and stored in CPDA-1 bags. Blood samples were refrigerated for 8 days and subsequently re-infused. The clinical, haematological and biochemical parameters were evaluated before blood collection and reinfusion, after 10 minutes of collection and reinfusion, after 3, 6, 12, 24, 48, 96 and 192 hours after collection and reinfusion. Results With respect to clinical parameters, we observed a decrease in heart rate after 24, 48 and 196 hours from reinfusion compared to basal values (p p p p  Conclusion Autologous transfusion in sheep slightly altered the physiological, biochemical and haematological responses of sheep, indicating that the technique proposed is safe and can be applied in the clinical practice of this species. The 8 d period was not sufficient for complete recovery of the haematological parameters after blood collection.

  7. Noninvasive biosensor and wireless interrogating system for glucose in blood

    Science.gov (United States)

    Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.

    2003-07-01

    Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.

  8. Design and experimental investigation of a stretched parabolic linear Fresnel reflector collecting system

    International Nuclear Information System (INIS)

    Zhu, Yanqing; Shi, Jifu; Li, Yujian; Wang, Leilei; Huang, Qizhang; Xu, Gang

    2016-01-01

    Highlights: • A parabolic primary mirror field is designed to reduce the gap between adjacent mirrors. • The movable receiver can reduce the end losses. • The thermal efficiency of 66% is achieved at Guangzhou in winter. - Abstract: This paper proposes a stretched parabolic linear Fresnel reflector (SPLFR) collecting system. The primary optical mirror field of the SPLFR collecting system and the second-stage concentrator of compound parabolic collector are designed. The mirrors located at the parabolic line are close to each other, which effectively reduce the gap between the adjacent mirrors. The end losses of the receiver are very important, especially in a small-scale collecting system. A movable receiver is introduced for the reduction of the end losses. Moreover, a stretched structure of SPLFR is designed for wind resistance. Finally, the thermal performance of the SPLFR collecting system with fixed and movable receiver located in Guangzhou is tested. The maximum thermal efficiency obtained by this collecting system with movable receiver is 66% which avoid the end losses effectively, and the solar collector thermal loss coefficient is 1.32 W/m"2 °C. The results show that the SPLFR collecting system has excellent thermal performance and a promising application future. Meanwhile, this system will provide a valuable reference for concentrating solar power technology.

  9. Blood banking services in India.

    Science.gov (United States)

    Sardana, V N

    1996-01-01

    India's health care sector has made impressive strides toward providing health for all by the year 2000. That progress, however, has not been supported by a modern transfusion services network which continues to improve itself. In India, blood collection, storage, and delivery occur mainly in blood banks attached to hospitals, most of which are under central and state government controls. A significant portion of blood banking activity is also done by voluntary agencies and private sector blood banks. A study found the blood transfusion services infrastructure to be highly decentralized and lacking of many critical resources; an overall shortage of blood, especially from volunteer donors; limited and erratic testing facilities; an extremely limited blood component production/availability/use; and a shortage of health care professionals in the field of transfusion services. Infrastructural modernization and the technical upgrading of skills in the blood banks would, however, provide India with a dynamic transfusion services network. The safety of blood transfusion, the national blood safety program, HIV testing facilities, modernization of blood banks, the rational use of blood, program management, manpower development, the legal framework, voluntary blood donation, and a 1996 Supreme Court judgement on the need to focus greater attention upon the blood program are discussed.

  10. Portable data collection terminal in the automated power consumption measurement system

    Science.gov (United States)

    Vologdin, S. V.; Shushkov, I. D.; Bysygin, E. K.

    2018-01-01

    Aim of efficiency increasing, automation process of electric energy data collection and processing is very important at present time. High cost of classic electric energy billing systems prevent from its mass application. Udmurtenergo Branch of IDGC of Center and Volga Region developed electronic automated system called “Mobile Energy Billing” based on data collection terminals. System joins electronic components based on service-oriented architecture, WCF services. At present time all parts of Udmurtenergo Branch electric network are connected to “Mobile Energy Billing” project. System capabilities are expanded due to flexible architecture.

  11. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cord blood processing system and storage container. 864.9900 Section 864.9900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That...

  12. Peptide-Mediated Liposomal Drug Delivery System Targeting Tumor Blood Vessels in Anticancer Therapy

    Directory of Open Access Journals (Sweden)

    Han-Chung Wu

    2010-01-01

    Full Text Available Solid tumors are known to recruit new blood vessels to support their growth. Therefore, unique molecules expressed on tumor endothelial cells can function as targets for the antiangiogenic therapy of cancer. Current efforts are focusing on developing therapeutic agents capable of specifically targeting cancer cells and tumor-associated microenvironments including tumor blood vessels. These therapies hold the promise of high efficacy and low toxicity. One recognized strategy for improving the therapeutic effectiveness of conventional chemotherapeutics is to encapsulate anticancer drugs into targeting liposomes that bind to the cell surface receptors expressed on tumor-associated endothelial cells. These anti-angiogenic drug delivery systems could be used to target both tumor blood vessels as well as the tumor cells, themselves. This article reviews the mechanisms and advantages of various present and potential methods using peptide-conjugated liposomes to specifically destroy tumor blood vessels in anticancer therapy.

  13. Increasing blood flow to exercising muscle attenuates systemic cardiovascular responses during dynamic exercise in humans.

    Science.gov (United States)

    Ichinose, Masashi; Ichinose-Kuwahara, Tomoko; Kondo, Narihiko; Nishiyasu, Takeshi

    2015-11-15

    Reducing blood flow to working muscles during dynamic exercise causes metabolites to accumulate within the active muscles and evokes systemic pressor responses. Whether a similar cardiovascular response is elicited with normal blood flow to exercising muscles during dynamic exercise remains unknown, however. To address that issue, we tested whether cardiovascular responses are affected by increases in blood flow to active muscles. Thirteen healthy subjects performed dynamic plantarflexion exercise for 12 min at 20%, 40%, and 60% of peak workload (EX20, EX40, and EX60) with their lower thigh enclosed in a negative pressure box. Under control conditions, the box pressure was the same as the ambient air pressure. Under negative pressure conditions, beginning 3 min after the start of the exercise, the box pressure was decreased by 20, 45, and then 70 mmHg in stepwise fashion with 3-min step durations. During EX20, the negative pressure had no effect on blood flow or the cardiovascular responses measured. However, application of negative pressure increased blood flow to the exercising leg during EX40 and EX60. This increase in blood flow had no significant effect on systemic cardiovascular responses during EX40, but it markedly attenuated the pressor responses otherwise seen during EX60. These results demonstrate that during mild exercise, normal blood flow to exercising muscle is not a factor eliciting cardiovascular responses, whereas it elicits an important pressor effect during moderate exercise. This suggests blood flow to exercising muscle is a major determinant of cardiovascular responses during dynamic exercise at higher than moderate intensity. Copyright © 2015 the American Physiological Society.

  14. "The Tramp", a blood donation propagandist?

    Science.gov (United States)

    Lefrère, J-J; Garraud, O

    2016-02-01

    The French pioneer for blood transfusion, who eventually organized the very early blood transfusion centers worldwide, went to imagine a scenario written in purpose for Charlie Chaplin, the unique character of "The Tramp" ("Charlot" in French). The movie Star was offered to feature a blood donation propagandist, and no longer the perpetual, well-known, "loser". This anecdote, besides being amusing, tells a lot on how Arnault Tzank encompassed all the difficulties in collecting blood enough to meet the demand, at all times; his proposal turns out to be extremely modern and questions nowadays marketing for blood donation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Development and Implementation of Production Area of Agricultural Product Data Collection System Based on Embedded System

    Science.gov (United States)

    Xi, Lei; Guo, Wei; Che, Yinchao; Zhang, Hao; Wang, Qiang; Ma, Xinming

    To solve problems in detecting the origin of agricultural products, this paper brings about an embedded data-based terminal, applies middleware thinking, and provides reusable long-range two-way data exchange module between business equipment and data acquisition systems. The system is constructed by data collection node and data center nodes. Data collection nodes taking embedded data terminal NetBoxII as the core, consisting of data acquisition interface layer, controlling information layer and data exchange layer, completing the data reading of different front-end acquisition equipments, and packing the data TCP to realize the data exchange between data center nodes according to the physical link (GPRS / CDMA / Ethernet). Data center node consists of the data exchange layer, the data persistence layer, and the business interface layer, which make the data collecting durable, and provide standardized data for business systems based on mapping relationship of collected data and business data. Relying on public communications networks, application of the system could establish the road of flow of information between the scene of origin certification and management center, and could realize the real-time collection, storage and processing between data of origin certification scene and databases of certification organization, and could achieve needs of long-range detection of agricultural origin.

  16. Multidrug resistant Salmonellae isolated from blood culture samples ...

    African Journals Online (AJOL)

    This study investigates the prevalence of R-plasmids in Salmonella sp. isolated from blood samples of suspected typhoid patients in Warri, Nigeria. A total of 136 blood samples were collected between May and December,2009 and screened for the presence of Salmonellae using standard blood culture techniques of which ...

  17. Feature test report for the Small Debris Collection and Packaging System

    International Nuclear Information System (INIS)

    Brisbin, S.A.

    1995-01-01

    The Spent Nuclear Fuel Equipment Engineering group performed feature testing of the Small Debris Collection and Packaging System (SDCPS) in the 305 Cold Test Facility from January 30, 1995, to February 1, 1995. Feature testing of the Small Debris Collection and Packaging System (SDCPS) was performed for the following reasons: To assess the feasibility of using ''drop-out'' vessels to collect small debris (<2.5 cm) in MK-II fuel canisters while transferring sludge to the Weasel Pit. To evaluate system performance under conditions similar to those in the K-Basins (e.g. submerged under 4.9 meters of water and operated with long handled tools) while using a surrogate sludge mixed with debris. To determine if canister weight could be used to predict the volume of sludge and/or debris contained within the canisters during system operation

  18. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system

    Directory of Open Access Journals (Sweden)

    N S Ozen

    2011-01-01

    Full Text Available Purpose: Differentiation of Staphylococcus aureus (S. aureus from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT, slide agglutination test (Dry Spot Staphytect Plus, conventional polymerase chain reaction (PCR and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. Materials and Methods: A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. Results: The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Conclusion: Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  19. Evaluation of the Secretor Status of ABO Blood Group Antigens in Saliva among Southern Rajasthan Population Using Absorption Inhibition Method.

    Science.gov (United States)

    Metgud, Rashmi; Khajuria, Nidhi; Mamta; Ramesh, Gayathri

    2016-02-01

    The ABO blood group system was the significant element for forensic serological examination of blood and body fluids in the past before the wide adaptation of DNA typing. A significant proportion of individuals (80%) are secretors, meaning that antigens present in the blood are also found in other body fluids such as saliva. Absorption inhibition is one such method that works by reducing strength of an antiserum based on type and amount of antigen present in the stains. To check the efficacy of identifying the blood group antigens in saliva and to know the secretor status using absorption inhibition method among southern Rajasthan population. Blood and saliva samples were collected from 80 individuals comprising 20 individuals in each blood group. The absorption inhibition method was used to determine the blood group antigens in the saliva and then the results were correlated with the blood group of the collected blood sample. The compiled data was statistically analysed using chi-square test. Blood groups A & O revealed 100% secretor status for both males and females. While blood groups B and AB revealed 95% secretor status. Secretor status evaluation of the ABO blood group antigen in saliva using absorption inhibition method can be a useful tool in forensic examination.

  20. A passive collection system for whole size fractions in river suspended solids

    International Nuclear Information System (INIS)

    Takeshi Matsunaga; Takahiro Nakanishi; Mariko Atarashi-Andoh; Erina Takeuchi; Katsunori Tsuduki; Syusaku Nishimura; Jun Koarashi; Shigeyoshi Otosaka; Tsutomu Sato; Seiya Nagao

    2015-01-01

    In order to solve difficulties in collection of river suspended solids (SS) such as frequent observations during stochastic rainfall events, a simple passive collection system of SS has been developed. It is composed of sequentially connected two large-scale filter vessels. A portion of river water flows down into the filter vessels utilizing a natural drop of streambed. The system enable us to carry out long-term, unmanned SS collection. It is also compatible with dissolved component collection. Its performance was validated in a forested catchment by applying to radiocesium and stable carbon transport. (author)

  1. A SYSTEM AND A DEVICE FOR ISOLATING CIRCULATING TUMOR CELLS FROM THE PERIPHERAL BLOOD IN VIVO

    Directory of Open Access Journals (Sweden)

    Michal Mego

    2015-08-01

    Full Text Available Circulating tumor cells (CTC play a crucial role in disseminating tumors and in the metastatic cascade. CTCs are found only in small numbers, and the limited amount of isolated CTCs makes it impossible to characterize them closely. This paper presents a proposal for a new system for isolating CTCs from the peripheral blood in vivo. The system enables CTCs to be isolated from the whole blood volume for further research and applications. The proposed system consists of magnetic nanoparticles covered by monoclonal antibodies against a common epithelial antigen, large supermagnets, which are used to control the position of the nanoparticles within the human body, and a special wire made of a magnetic core wrapped in a non-magnetic shell. The system could be used not only for isolating CTCs, but also for in vivo isolation of other rare cells from the peripheral blood, including hematopoietic and/or mesenchymal stem cells, with applications in regenerative medicine and/or in stem cell transplantation.

  2. [The francophone Africa blood transfusion research network: a five-year report].

    Science.gov (United States)

    Tagny, Claude Tayou; Murphy, Edward L; Lefrère, Jean-Jacques

    2014-03-01

    There has been little blood safety research in sub-Saharan Africa, often consisting of local efforts whose findings had limited impact The "Francophone Africa Transfusion Research Network" was created in May 2007 with the objective of developing common evidence-based blood safety policies that may be adapted to each country's situation. The Group's activities to date have focused mainly on obtaining epidemiological and laboratory data on blood transfusion and on suggesting blood safety strategies, particularly in the field of TTIs. To carry out such research activities, the group works closely with the National Blood Transfusion Services (NBTS), the Regional Blood Transfusion Services (RBTS), the hospital blood banks (HBB) and collection stations. For the first 5years, four research priorities were identified: (i) descriptive studies of the characteristics of francophone African blood donors and blood centers; (ii) estimation of the residual risk of transfusion-transmitted major viral infections; (iii) an analysis of blood donor deferral strategies; and (iv) a description of TTI screening strategies and an external quality assurance system (EQAS) project. During this period, seven projects have been implemented at the national level and published and five multicenter studies were conducted and published. The present review reports the main observations and recommendations from those studies that could improve blood safety statute in Africa. Copyright © 2013. Published by Elsevier SAS.

  3. Complete blood count reference values of cord blood in Taiwan and the influence of gender and delivery route on them.

    Science.gov (United States)

    Chang, Yu-Hsun; Yang, Shang-Hsien; Wang, Tso-Fu; Lin, Teng-Yi; Yang, Kuo-Liang; Chen, Shu-Huey

    2011-06-01

    Cord blood banking has become more popular in recent years. Checking cord blood complete blood count (CBC) and white blood cell (WBC) differential counts (DCs) is essential before cryopreserving the cord blood units. Therefore, establishing the normal reference values of cord blood CBC and WBC DC is important in clinical practice and research. To obtain a large-scale population-based normal CBC and WBC DC reference values of healthy neonates' cord blood from a public cord blood bank and to investigate the influence of the gender and delivery route. From September 2001 to November 2006, the cord blood of healthy Taiwanese neonates with gestational age 36 weeks and more were collected by Tzu Chi Cord Blood Bank with written informed consents. All cord blood samples were analyzed by Sysmex XE2100 automated hematology analyzer (Sysmex Corporation, Kobe, Japan) to obtain the CBC. The WBC DC was calculated by manual method. We used Student's t test and Mann-Whitney U test for investigating the influences of gender and delivery route on the CBC and WBC DC reference values. The results were presented by mean±standard deviation or 2.5-97.5th percentiles. In the study period, totally 5602 cord blood samples were collected eligibly for analysis. The cord blood CBC and WBC DC normal reference values were calculated. The female neonates had significantly higher mean corpuscular volume, platelet count, and WBC count, but lower red blood cell (RBC) count, hemoglobin (Hb), hematocrit, and mean corpuscular Hb concentration values (pTaiwan. Gender and delivery routes were important confounding factors that influenced the cord blood CBC and WBC DC values. Copyright © 2011. Published by Elsevier B.V.

  4. Analysis of the research sample collections of Uppsala biobank.

    Science.gov (United States)

    Engelmark, Malin T; Beskow, Anna H

    2014-10-01

    Uppsala Biobank is the joint and only biobank organization of the two principals, Uppsala University and Uppsala University Hospital. Biobanks are required to have updated registries on sample collection composition and management in order to fulfill legal regulations. We report here the results from the first comprehensive and overall analysis of the 131 research sample collections organized in the biobank. The results show that the median of the number of samples in the collections was 700 and that the number of samples varied from less than 500 to over one million. Blood samples, such as whole blood, serum, and plasma, were included in the vast majority, 84.0%, of the research sample collections. Also, as much as 95.5% of the newly collected samples within healthcare included blood samples, which further supports the concept that blood samples have fundamental importance for medical research. Tissue samples were also commonly used and occurred in 39.7% of the research sample collections, often combined with other types of samples. In total, 96.9% of the 131 sample collections included samples collected for healthcare, showing the importance of healthcare as a research infrastructure. Of the collections that had accessed existing samples from healthcare, as much as 96.3% included tissue samples from the Department of Pathology, which shows the importance of pathology samples as a resource for medical research. Analysis of different research areas shows that the most common of known public health diseases are covered. Collections that had generated the most publications, up to over 300, contained a large number of samples collected systematically and repeatedly over many years. More knowledge about existing biobank materials, together with public registries on sample collections, will support research collaborations, improve transparency, and bring us closer to the goals of biobanks, which is to save and prolong human lives and improve health and quality of life.

  5. Smartphone-based assessment of blood alteration severity

    Science.gov (United States)

    Li, Xianglin; Xue, Jiaxin; Li, Wei; Li, Ting

    2018-02-01

    Blood quality and safety management is a critical issue for cold chain transportation of blood or blood-based biological reagent. The conventional methods of blood alteration severity assessment mainly rely on kit test or blood-gas analysis required opening the blood package to get samples, which cause possible blood pollution and are complicate, timeconsuming, and expensive. Here we proposed to develop a portable, real-time, safety, easy-operated and low cost method aimed at assessing blood alteration severity. Color images of the blood in transparent blood bags were collected with a smartphone and the alteration severity of the blood was assessed by the smartphone app offered analysis of RGB color values of the blood. The algorithm is based on a large number sample of RGB values of blood at different alteration degree. The blood quality results evaluated by the smartphone are in accordance with the actual data. This study indicates the potential of smart phone in real time, convenient, and reliable blood quality assessment.

  6. Applications of blood group genotyping

    Directory of Open Access Journals (Sweden)

    Mariza A. Mota

    2006-03-01

    Full Text Available Introduction: The determination of blood group polymorphism atthe genomic level facilitates the resolution of clinical problemsthat cannot be addressed by hemagglutination. They are useful to(a determine antigen types for which currently available antibodiesare weakly reactive; (b type patients who have been recentlytransfused; (c identify fetuses at risk for hemolytic disease of thenewborn; and (d to increase the reliability of repositories of antigennegative RBCs for transfusion. Objectives: This review assessedthe current applications of blood group genotyping in transfusionmedicine and hemolytic disease of the newborn. Search strategy:Blood group genotyping studies and reviews were searched ingeneral database (MEDLINE and references were reviewed.Selection criteria: All published data and reviews were eligible forinclusion provided they reported results for molecular basis ofblood group antigens, DNA analysis for blood group polymorphisms,determination of fetal group status and applications of blood groupgenotyping in blood transfusion. Data collection: All data werecollected based on studies and reviews of blood grouppolymorphisms and their clinical applications.

  7. [Sampling, storage and transport of biological materials collected from living and deceased subjects for determination of concentration levels of ethyl alcohol and similarly acting substances. A proposal of updating the blood and urine sampling protocol].

    Science.gov (United States)

    Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew

    2007-01-01

    The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.

  8. Gingival crevicular blood for screening of blood glucose level in patients with & without diabetes: a chair-side test.

    Science.gov (United States)

    Bhavsar, M V; Brahmbhatt, N A; Sahayata, V; Bhavsar, N V

    2016-05-01

    Diabetes is a pandemic disease with increasing prevalence and serious complications. Periodontitis being one of its presentation and is its sixth recognized complication. This study compares blood glucose levels in gingival crevicular blood of patients with and without diabetes elicited during routine periodontal probing and venous blood sample. Seventy patients with moderate gingivitis and periodontitis positive for bleeding on probing were chosen. All the subjects were divided in two groups, group I consisted of 35 diabetic and group II of 35 non-diabetic subjects. Blood from the gingiva of the most inflamed site was collected with the test strip of a glucose self-monitoring device, and the blood glucose levels were measured. At the same time, intravenous blood was collected for measurement in a laboratory glucose analyzer. Gingival index and probing pocket depth were evaluated for each subject at same time. The mean GCB levels and VB derived from all samples were 156.07 ± 49.23 mg dl(-1) and 156 ± 49.89 mg dl(-1) , respectively, for diabetic group and 90.80 ± 11.07 and 93.41 ± 9.30 for non-diabetic group. In both the groups, the difference between GCB and VB glucose levels was non-significant (P > 0.005). Highly significant correlation between GCB and VB (r = 0.972 for diabetic and r = 0.721 for non-diabetic) in both the groups was found. The data from this study show that GCB collected during diagnostic periodontal examination can be an excellent source for estimation of blood sugar or glucometric analysis. This technique is also suitable for routine screening of diabetic and early diagnosis of unknown diabetic cases. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Benzophenone-type UV filters in urine and blood from children, adults, and pregnant women in China: Partitioning between blood and urine as well as maternal and fetal cord blood

    International Nuclear Information System (INIS)

    Zhang, Tao; Sun, Hongwen; Qin, Xiaolei; Wu, Qian; Zhang, Yanfeng; Ma, Jing; Kannan, Kurunthachalam

    2013-01-01

    Limited information exists on the exposure of benzophenone (BP)-type UV filters (i.e., sunscreen compounds) in children, adults, and pregnant women in China. In this study, we determined the concentrations of five BP derivatives, BP-1, BP-2, BP-3, BP-8, and 4OH-BP in urine (n = 101) as well as paired specimens of blood and urine (n = 24 pairs) collected from adults; in matched maternal and fetal cord blood (n = 20 pairs) collected from pregnant women; and in blood collected from children (n = 10). 4OH-BP, BP-1, and BP-3 were found in 61%, 57%, and 25%, respectively, of the urine samples analyzed. 4OH-BP was found in all blood samples; BP-3 was found more frequently in the blood of adults (83%), followed, in decreasing order, by pregnant women (35%) and children (30%). Among all adults, urinary BP-3 concentrations were significantly (p < 0.001) positively correlated with urinary BP-1 concentrations. Nevertheless, no significant correlations were found between urinary concentrations of BP-3 (or BP-1) and 4OH-BP. Our results suggest that human exposure to BP-3 and BP-1 is related, whereas 4OH-BP originates from a discrete source. Females had higher urinary concentrations of BP-3, BP-1 and 4OH-BP than males. The distribution profiles of BP-1 and its parent compound (i.e., BP-3) in urine decreased with increasing age of donors (p < 0.05). The ratio of concentrations of BP-3 between blood and urine was 0.21 in adults, which was significantly lower than that for 4OH-BP (0.36). The concentration ratio of BPs between cord blood and maternal blood was higher for 4OH-BP (0.61) than that for BP-3 (0.48), which suggested greater trans-placental transfer potential of 4OH-BP. This is the first study to document the occurrence of BPs in paired urine and blood, and in matched maternal and fetal cord blood. Highlights: • Benzophenone (BP) concentrations are determined in paired blood and urine for the first time. • BP-3 and 4OH-BP partition preferentially into urine. • Cord to

  10. Benzophenone-type UV filters in urine and blood from children, adults, and pregnant women in China: Partitioning between blood and urine as well as maternal and fetal cord blood

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Tao; Sun, Hongwen; Qin, Xiaolei [College of Environmental Sciences and Engineering, Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Nankai University, Tianjin 300071 (China); Wu, Qian [Wadsworth Center, New York State Department of Health, Albany, NY 12201 (United States); Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Albany, NY 12201 (United States); Zhang, Yanfeng [College of Environmental Sciences and Engineering, Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, Nankai University, Tianjin 300071 (China); Ma, Jing [Applied Radiation Institute, School of Environmental and Chemical Engineering, Shanghai University, 99 Shangda Road, P.O. Box 144, Shanghai 200444 (China); Kannan, Kurunthachalam, E-mail: kkannan@wadsworth.org [Wadsworth Center, New York State Department of Health, Albany, NY 12201 (United States); Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Albany, NY 12201 (United States); International Joint Research Center for Persistent Toxic Substances, State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150090 (China)

    2013-09-01

    Limited information exists on the exposure of benzophenone (BP)-type UV filters (i.e., sunscreen compounds) in children, adults, and pregnant women in China. In this study, we determined the concentrations of five BP derivatives, BP-1, BP-2, BP-3, BP-8, and 4OH-BP in urine (n = 101) as well as paired specimens of blood and urine (n = 24 pairs) collected from adults; in matched maternal and fetal cord blood (n = 20 pairs) collected from pregnant women; and in blood collected from children (n = 10). 4OH-BP, BP-1, and BP-3 were found in 61%, 57%, and 25%, respectively, of the urine samples analyzed. 4OH-BP was found in all blood samples; BP-3 was found more frequently in the blood of adults (83%), followed, in decreasing order, by pregnant women (35%) and children (30%). Among all adults, urinary BP-3 concentrations were significantly (p < 0.001) positively correlated with urinary BP-1 concentrations. Nevertheless, no significant correlations were found between urinary concentrations of BP-3 (or BP-1) and 4OH-BP. Our results suggest that human exposure to BP-3 and BP-1 is related, whereas 4OH-BP originates from a discrete source. Females had higher urinary concentrations of BP-3, BP-1 and 4OH-BP than males. The distribution profiles of BP-1 and its parent compound (i.e., BP-3) in urine decreased with increasing age of donors (p < 0.05). The ratio of concentrations of BP-3 between blood and urine was 0.21 in adults, which was significantly lower than that for 4OH-BP (0.36). The concentration ratio of BPs between cord blood and maternal blood was higher for 4OH-BP (0.61) than that for BP-3 (0.48), which suggested greater trans-placental transfer potential of 4OH-BP. This is the first study to document the occurrence of BPs in paired urine and blood, and in matched maternal and fetal cord blood. Highlights: • Benzophenone (BP) concentrations are determined in paired blood and urine for the first time. • BP-3 and 4OH-BP partition preferentially into urine. • Cord to

  11. The LANSCE (Los Alamos Neutron Scattering Center) target data collection system

    International Nuclear Information System (INIS)

    Kernodle, A.K.

    1989-01-01

    The Los Alamos Neutron Scattering Center (LANSCE) Target Data Collection System is the result of an effort to provide a base of information from which to draw conclusions on the performance and operational condition of the overall LANSCE target system. During the conceptualization of the system, several goals were defined. A survey was made of both custom-made and off-the-shelf hardware and software that were capable of meeting these goals. The first stage of the system was successfully implemented for the LANSCE run cycle 52. From the operational experience gained thus far, it appears that the LANSCE Target Data Collection System will meet all of the previously defined requirements

  12. Management of blood donors and blood donations from individuals found to have a positive direct antiglobulin test.

    Science.gov (United States)

    Hannon, Judith L

    2012-04-01

    The medical literature is replete with articles addressing the diagnosis and management of patients with a positive direct antiglobulin test (DAT). However, there is scant information addressing the management of blood donors and blood donations found to have a positive DAT. Practices vary considerably between countries and blood suppliers within countries, and there is no standardized approach to the management of these blood donors or the blood products prepared from their donations. Recent evidence from Israel suggests that the finding of a positive DAT in a blood donor may not be as benign as previously thought. Therefore, it may be prudent for blood collection agencies to periodically reexamine their approach to the management of blood donors with a positive DAT and their donations. This article reviews the available literature and explores options for the management of DAT-positive blood donors and their blood donations. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Application of mobile blood purification system in the treatment of acute renal failure dog model in the field environment

    Directory of Open Access Journals (Sweden)

    Zhi-min ZHANG

    2014-01-01

    Full Text Available Objective To evaluate the stability, safety and efficacy of mobile blood purification system in the treatment of acute renal failure dog model in the field environment. Methods The acute renal failure model was established in 4 dogs by bilateral nephrectomy, which was thereafter treated with the mobile blood purification system. The evaluation of functional index of the mobile blood purification system was performed after a short-time (2 hours and conventional (4 hours dialysis treatment. Results The mobile blood purification system ran stably in the field environment at a blood flow of 150-180ml/min, a dialysate velocity of 2000ml/h, a replacement fluid velocity of 2000ml/h, and ultrafiltration rate of 100-200ml/h. All the functions of alarming system worked well, including static upper limit alarm of ultrafiltration pressure (>100 mmHg, upper limit alarm of ambulatory arterial pressure (>400mmHg, upper limit alarm of ambulatory venous pressure (>400mmHg, bubble alarm of vascular access, bubble alarm during the infusion of solutions, pressure alarm at the substitution pump segment and blood leaking alarm. The vital signs of the 4 dogs with acute renal failure kept stable during the treatment. After the treatment, a remarkable decrease was seen in the levels of serum urea nitrogen, creatinine and serum potassium (P0.05. Conclusions The mobile blood purification system runs normally even in a field environment. It is a flexible and portable device with a great performance in safety and stability in the treatment of acute renal failure. DOI: 10.11855/j.issn.0577-7402.2013.12.15

  14. Bottlenecks of blood processing in Uganda

    NARCIS (Netherlands)

    Kajja, I.; Kyeyune, D.; Bimenya, G. S.; Sibinga, C. T. S.

    2010-01-01

    Aim: To identify where and why delays occur in Uganda blood banks. Background: The timely provision and supply of safe and efficacious blood components to hospitals depends on sound systems in the processing blood banks. Poorly managed systems lead to apparent blood shortages in hospitals and

  15. Establishing and evaluating bar-code technology in blood sampling system: a model based on human centered human-centered design method.

    Science.gov (United States)

    Chou, Shin-Shang; Yan, Hsiu-Fang; Huang, Hsiu-Ya; Tseng, Kuan-Jui; Kuo, Shu-Chen

    2012-01-01

    This study intended to use a human-centered design study method to develop a bar-code technology in blood sampling process. By using the multilevel analysis to gather the information, the bar-code technology has been constructed to identify the patient's identification, simplify the work process, and prevent medical error rates. A Technology Acceptance Model questionnaire was developed to assess the effectiveness of system and the data of patient's identification and sample errors were collected daily. The average scores of 8 items users' perceived ease of use was 25.21(3.72), 9 items users' perceived usefulness was 28.53(5.00), and 14 items task-technology fit was 52.24(7.09), the rate of patient identification error and samples with order cancelled were down to zero, however, new errors were generated after the new system deployed; which were the position of barcode stickers on the sample tubes. Overall, more than half of nurses (62.5%) were willing to use the new system.

  16. Symptoms of Blood Disorders

    Science.gov (United States)

    ... or immune system proteins can cause increased blood viscosity (thickening of the blood). Increased platelets or blood ... by anemia Pica (eating of ice, dirt, or clay) suggests iron deficiency anemia Drugs Mentioned In This ...

  17. Electrical Collection and Transmission Systems for Offshore Wind Power: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Green, J.; Bowen, A.; Fingersh, L.J.; Wan, Y.

    2007-03-01

    The electrical systems needed for offshore wind farms to collect power from wind turbines--and transmit it to shore--will be a significant cost element of these systems. This paper describes the development of a simplified model of the cost and performance of such systems.

  18. The order of draw of blood specimens into additive containing tubes not affect potassium and calcium measurements.

    Science.gov (United States)

    Majid, A; Heaney, D C; Padmanabhan, N; Spooner, R

    1996-12-01

    The effect of order of draw when taking blood into tubes containing additive was investigated in 47 medical inpatients; 12 of these patients acted as a control group. The samples were analysed in the order in which they were withdrawn. The results of potassium and calcium concentrations did not differ significantly between groups. Manufacturers recommend a specific order of draw when taking blood using vacuum based blood collection systems, which are routinely used in many hospitals. The results of this study, however, show that order of draw has no effect on calcium or potassium concentrations.

  19. Plasmodium falciparum malaria associated with ABO blood ...

    African Journals Online (AJOL)

    The present study was carried out to investigate the relationship between blood group types and P. falciparum malaria, as well as malaria preventive measures. The venous blood specimens were collected, processed, Giemsa-stained and examined microscopically. ABO groups were determined by agglutination test using ...

  20. Development of a multicriteria assessment model for ranking biomass feedstock collection and transportation systems.

    Science.gov (United States)

    Kumar, Amit; Sokhansanj, Shahab; Flynn, Peter C

    2006-01-01

    This study details multicriteria assessment methodology that integrates economic, social, environmental, and technical factors in order to rank alternatives for biomass collection and transportation systems. Ranking of biomass collection systems is based on cost of delivered biomass, quality of biomass supplied, emissions during collection, energy input to the chain operations, and maturity of supply system technologies. The assessment methodology is used to evaluate alternatives for collecting 1.8 x 10(6) dry t/yr based on assumptions made on performance of various assemblies of biomass collection systems. A proposed collection option using loafer/ stacker was shown to be the best option followed by ensiling and baling. Ranking of biomass transport systems is based on cost of biomass transport, emissions during transport, traffic congestion, and maturity of different technologies. At a capacity of 4 x 10(6) dry t/yr, rail transport was shown to be the best option, followed by truck transport and pipeline transport, respectively. These rankings depend highly on assumed maturity of technologies and scale of utilization. These may change if technologies such as loafing or ensiling (wet storage) methods are proved to be infeasible for large-scale collection systems.