WorldWideScience

Sample records for black electrical tape

  1. Examination of writings concealed by black pressure sensitive adhesive tape.

    Science.gov (United States)

    Mahajan, Meenakshi; Arya, S P

    2007-09-01

    Examination of concealed writing is often a challenge for forensic document examiners. Although the published literature describes many techniques, these are often only successful when the writing has been concealed by pencil, pen, or by spreading inks of different tint or by smearing of the writing with colored fluids. When black pressure sensitive adhesive (PSA) tape is used, these procedures are ineffective. The present report describes the use of a straight chain hydrocarbon to remove the PSA tape and allow a comparison of the concealed writing with that of a suspect. The use of the solvent had no observable effect on either the writing or the substrate. The procedure is rapid and easy to use and is also effective with other colored PSA tapes.

  2. Degradation characteristics of 2G HTS tapes with respect to an electrical breakdown

    International Nuclear Information System (INIS)

    Kang, Jong O; Lee, On You; Mo, Young Kyu; Kim, Jun Il; Bang, Seung Min; Lee, Hong Seok; Kang, Hyoung Ku; Lee, Jae Hun; Jang, Cheol Yeong

    2015-01-01

    The electrical insulation design for a superconducting coil system is important for developing high voltage superconducting apparatuses. Also, the degraded characteristics of superconducting tapes due to an electrical breakdown should be considered for superconducting coils design. In this study, the degradation characteristics of 2G high temperature superconducting (HTS) tapes were studied with respect to electrical breakdown tests. The degradation tests of 2G HTS tapes were performed with various stabilizer materials. The degradation characteristics of 2G HTS tapes such as critical current(Ic) and index number were observed by performing electrical breakdown tests. It was found that the characteristics such as Ic and index number can be degraded by an electrical breakdown. Moreover, it was concluded that the degradation characteristics of 2G HTS tapes were affected by a stabilizer material and applied breakdown voltage. The cross sectional view of 2G HTS tapes was observed by using a scanning electron microscope (SEM). As results, it is found that the degradation characteristics of 2G HTS tapes are concerned with hardness and electrical resistivity of stabilizer layers

  3. Electrical heating tapes for hot water piping and frost protection; Elektrische Heizbaender fuer Warmwasserleitungen und Frostschutz

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J.

    2003-07-01

    This leaflet issued by the Swiss Federal Office of Energy and professional plumbing and installation associations presents information and recommendations on the use of electrical heating tapes in sanitary installations and rainwater piping. The considerable amount of electrical power needed for the operation of these heating tapes is discussed and methods of reducing consumption by the use efficient controllers are described. It is further mentioned that the correct design and planning of sanitary installations can help reduce the necessity for the use of heating tapes. Cost comparisons are made between heat-tape and circulation-based solutions for different heat sources. Tips are provided on installation details. Frost protection for piping in unheated rooms and for rainwater down-pipes is also discussed.

  4. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    Science.gov (United States)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  5. Electric currents in REBaCuO superconducting tapes

    Czech Academy of Sciences Publication Activity Database

    Jirsa, Miloš; Rameš, Michal; Ďuran, Ivan; Melíšek, T.; Kováč, P.; Viererbl, L.

    2017-01-01

    Roč. 30, č. 4 (2017), 1-8, č. článku 045010. ISSN 0953-2048 EU Projects: European Commission(XE) 633053 - EUROfusion Institutional support: RVO:68378271 ; RVO:61389021 Keywords : superconducting tapes * REBaCuO * critical currents * induction and transport * pinning force density * magnetic relaxation * neutron irradiation Subject RIV: BM - Solid Matter Physics ; Magnetism; BL - Plasma and Gas Discharge Physics (UFP-V) OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.); Fluids and plasma physics (including surface physics) (UFP-V) Impact factor: 2.878, year: 2016

  6. A comparison of acute effects between Kinesio tape and electrical muscle elongation in hamstring extensibility.

    Science.gov (United States)

    Espejo-Antúnez, L; López-Miñarro, P A; Garrido-Ardila, E M; Castillo-Lozano, R; Domínguez-Vera, P; Maya-Martín, J; Albornoz-Cabello, M

    2015-01-01

    To improve hamstring extensibility some methods have been analyzed and compared for determining their acute and chronic effectiveness. To compare the immediate effect of electrical muscle elongation (EME) versus Kinesio tape (KT) in hamstring muscle extensibility. One hundred and twenty adult amateur athletes with hamstring shortness (straight leg raise test angle Kinesio tape are effective techniques in the short-term in amateur athletes with decreased hamstring extensibility. The higher increase of hamstring extensibility, with a better clinical effect was achieved with the application of electrical muscle elongation. However, no significant differences were found when comparing the effectiveness of both techniques.

  7. Industrial production, capacity utilization, and electric power tape. Data file

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The industrial production index is a measure of the physical output of the nation's factories, mines, and electric and gas utilities expressed as a percentage of production in a base period, currently 1987. Capacity indexes, based on the Federal Reserve's industrial production indexes, are estimated for total industry, which covers manufacturing, mining, and utilities industries. Both the capacity and output indexes are expressed as a percentage of 1987 output. Utilization rates are then derived by dividing the capacity index into the associated production indexes.

  8. Study of the electric Held in HTS tape caused by perpendicular AC magnetic field

    International Nuclear Information System (INIS)

    Roiberg, V; Kopansky, F.

    2004-01-01

    Full Text: In a previous work we studied the influence of AC magnetic fields on voltage-currents (V-I) characteristics of high temperature superconducting (HTS) multi filament BSCC0-2223 tapes. It was found that AC magnetic fields perpendicular to the ab plane (the wide surface of the tape) cause a linear decrease of the critical current (IC) with amplitude of the AC magnetic field. The degradation of IC in .AC field was explained by the geometrical model according to which the transport current floe: is confined to the central zone of the tape where .AC field does not penetrate. For deeper understanding of the observed phenomena we carried out a study of the time dependence of the electric field during the cycle of AC field. At the same time we expanded the frequency range to low frequencies down to 1 Hz. The main results of the work are as following. 1. The time modulation of the electric field E in the HTS tape carrying transport DC current has the double frequency relating to AC magnetic field. 2. In field amplitudes less than 70 G the electric field modulation decreases with increasing frequency in opposite to its well-pronounced increase in higher AC field amplitudes. Alcove 70 G, the electric field increases with increasing the frequency of the external magnetic field. The wave forms of the electric field are different in both amplitudes ranges. 3. E-I curves of the tape in low amplitudes are frequency independent and coincide with E-l curves in AC field with intensity equal to the AC field amplitude. 4. In high AC field amplitudes, a strong dependence of the E-I curves on frequency is observed in the frequency range of 1-40 Hz and no dependence is observed in higher frequencies. Our results suggest that a combination of the geometrical model with flux creep concepts is necessary for a better understanding of the electric field behavior in our measurement conditions

  9. Investigation of electrical characteristics of no-insulation coil wound with surface-processed HTS tape

    Science.gov (United States)

    Jeon, Haeryong; Lee, Woo Seung; Kim, Jinsub; Baek, Geonwoo; Jeon, Sangsu; Yoon, Yong Soo; Ko, Tae Kuk

    2017-08-01

    This paper deals with the electrical characteristics of no-insulation coil wound with surface-processed HTS tape. The bypassing current path through turn-to-turn contacts within a coil is formed in the no-insulation coil, and this bypassing current path determines two characteristics: 1) self-protection and 2) charge-discharge delay. The amplitude of bypassing current is determined by contact resistance between the turn-to-turn contacts of the no-insulation coil. The surface roughness of the HTS tape is one of the parameters to change the contact resistance. The HTS tapes were processed to roughen by bead blast and abrasive paper, and the no-insulation coil is fabricated using processed HTS tape. We have studied the charge-discharge delay and self-protecting characteristic of each no-insulation coil by 1) sudden discharge tests and 2) overcurrent tests. The FEM simulations of contact resistance of no-insulation coil were carried out. The contact surface resistance of a case processed by abrasive paper has almost three times larger than that of reference no-insulation coil, and a case processed by bead blast presents almost same contact surface resistance with reference no-insulation coil.

  10. Electrically conducting oxide buffer layers on biaxially textured nickel alloy tapes by reel-to-reel MOCVD process

    International Nuclear Information System (INIS)

    Stadel, O; Samoilenkov, S V; Muydinov, R Yu; Schmidt, J; Keune, H; Wahl, G; Gorbenko, O Yu; Korsakov, I E; Melnikov, O V; Kaul, A R

    2006-01-01

    Reel-to-reel MOCVD process for continuous growth of electrically conducting buffer layers on biaxially textured Ni5W tapes has been developed. The new buffer layer architechture is presented: 200 nm (La, Ba) 2 CuO 4 /40 nm (La, Ba)MnO 3 /Ni5W. Constituting layers with high structural quality have been grown on moving tapes (in plane FWHM ≤ 6 0 and out of plane FWHM ≤ 3 0 )

  11. Electrical and mechanical properties of Bi-2223/Ag/barrier/Ag composite tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Goemoery, F.; Oduleye, O.O.; Alford, N.McN.; Pachla, W.; Diduszko, R.

    2000-01-01

    Bi-2223/Ag/barrier/Ag single-core tapes with various oxide barrier materials (BaZrO 3 , SrCO 3 , ZrO 2 and Al 2 O 3 ) have been prepared by PIT. The I-V curves and ac susceptibility measurements have been performed for tapes with identical heat treatment history. Young's moduli of these tape samples have been evaluated by three-point bending and the structure of barrier powders and BSCCO cores was analysed by SEM and XRD, respectively. It was found that the shape of I-V curves, the current transfer lengths and the mechanical properties of tapes are all affected by the oxide barrier type and the barrier thickness, as well as by its porosity and uniformity. This is because the oxide barrier controls the oxygen diffusion during the tape heat treatment and simultaneously the HTS phase formation kinetics, its purity and content within the superconducting core. On the base of the results obtained for single-core tapes, two kinds of multifilamentary composite were made and tested. (author)

  12. Extreme black hole with an electric dipole moment

    International Nuclear Information System (INIS)

    Horowitz, G.T.; Tada, T.

    1996-01-01

    We construct a new extreme black hole solution in a toroidally compactified heterotic string theory. The black hole saturates the Bogomol close-quote nyi bound, has zero angular momentum, but a nonzero electric dipole moment. It is obtained by starting with a higher-dimensional rotating charged black hole, and compactifying one direction in the plane of rotation. copyright 1996 The American Physical Society

  13. Electrical deicing utilizing carbon fiber tape for asphalt approach and crosswalk phase I - literature review.

    Science.gov (United States)

    2016-06-30

    The purpose of this study is to provide a comprehensive literature review of electrical deicing technology for possible application in asphalt approach and crosswalks. A : thorough review of existing and emerging deicing technology for snow/ice melti...

  14. Electrical conductivity of conductive carbon blacks: influence of surface chemistry and topology

    International Nuclear Information System (INIS)

    Pantea, Dana; Darmstadt, Hans; Kaliaguine, Serge; Roy, Christian

    2003-01-01

    Conductive carbon blacks from different manufacturers were studied in order to obtain some insight into the relation between their electrical conductivity and their surface properties. The surface chemistry was studied by X-ray photoelectron spectroscopy (XPS) and static secondary ion mass spectroscopy (SIMS), whereas the topology of the carbon black surface was investigated using low-pressure nitrogen adsorption. All these techniques yield information on the graphitic character of the surface. In general, the electrical conductivity of the conductive blacks increases with the graphitic character of the surface. For low surface area conductive blacks, the electrical conductivity correlates well with the surface chemistry. In the case of the XPS and SIMS data, this correlation is also valid when other types of carbon blacks such as thermal and furnace blacks are included, confirming the determining influence of the carbon black surface chemistry on the electrical conductivity

  15. Forensic utility of the carbon isotope ratio of PVC tape backings

    Science.gov (United States)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  16. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  17. Thickness effect on electric resistivity on polystyrene and carbon black- based composites

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Lopez, S; Vigueras-Santiago, E [Laboratorio de Investigacion y Desarrollo de Materiales Avanzados (LIDMA) Facultad de Quimica, Paseo Colon Esquina con Paseo Tollocan, s/n, CP 50000, Toluca (Mexico); Mayorga-Rojas, M; Reyes-Contreras, D, E-mail: eviguerass@uaemex.m [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico. Av. Instituto Literario 100 Ote. C. P. 50000, Toluca (Mexico)

    2009-05-01

    Changes on electrical resistivity were experimentally studied for polystyrene and carbon black-based composites respect to the temperature. 22% w/w carbon black composite films at 30{mu}m, 2mm y 1cm thick were submitted to thermal heating-cooling cycles from room temperature to 100 deg. C, slightly up to T{sub g} of the composite. For each cycle changes on electrical resistivity constituent a hysteresis loop that depends on the sample thickness. The changes during the heating stage could be explained as a consequence of the thermal expansion and mobility of the polymer chains at T{sub g}, producing a disconnecting of the electrical contacts among carbon black particles and an important increasing (200%) of the electrical resistivity. For each cycle, the hysteresis loop was observed in thicker samples, whereas for 30 mu m thickness sample the hysteresis loop was lost after four cycles.

  18. Thickness effect on electric resistivity on polystyrene and carbon black- based composites

    International Nuclear Information System (INIS)

    Hernandez-Lopez, S; Vigueras-Santiago, E; Mayorga-Rojas, M; Reyes-Contreras, D

    2009-01-01

    Changes on electrical resistivity were experimentally studied for polystyrene and carbon black-based composites respect to the temperature. 22% w/w carbon black composite films at 30 μm, 2mm y 1cm thick were submitted to thermal heating-cooling cycles from room temperature to 100 deg. C, slightly up to T g of the composite. For each cycle changes on electrical resistivity constituent a hysteresis loop that depends on the sample thickness. The changes during the heating stage could be explained as a consequence of the thermal expansion and mobility of the polymer chains at T g , producing a disconnecting of the electrical contacts among carbon black particles and an important increasing (200%) of the electrical resistivity. For each cycle, the hysteresis loop was observed in thicker samples, whereas for 30 μ m thickness sample the hysteresis loop was lost after four cycles.

  19. Major electric utilities, licensees, and others. Annual report (Form 1), 1990 (field definition of record layout). Data tape documentation

    International Nuclear Information System (INIS)

    1990-01-01

    Data are tabulated from annual reports filed with the Federal Energy Regulatory Commission by 182 major electric utilities. Major electric utilities are defined as those utilities which have had, in the last three consecutive calendar years, sales or transmission services that exceeded one of the following: one million megawatthours of total annual sales, 100 megawatthours of annual sales for resales, 600 megawatthours of gross interchange out, or 500 megawatthours of wheeling for others. Data included: financial and operational balance sheets; income and retained earnings statements; statements of changes in financial position; capital stock and long-term debt; electric operating revenues, customers, and sales by classes of service; electric operation and maintenance expenses; data per type of utility rate base and rates of return on common equity; research, development, and demonstration; and environmental protection facilities and expenses

  20. Electrical heating tapes, their use, energy consumption and energy savings potential; Elektrische Heizbaender. Anwendungen, Energieverbrauch und Sparmoeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J. [Arena, Zuerich (Switzerland); Lingenhel, S. [E Viva, Basel (Switzerland)

    2002-07-01

    Heating cables require about 0.6% of Swiss electricity consumption, approximately as much as all TV-sets. Most important applications are domestic hot water distribution tubing, frost protection (tubing, gutters) and industrial tubing, each requiring about 1/3. For over 10 years, self-regulating technology is standard for heating cables and offers pre-defined maintenance temperatures. To minimize electricity consumption, in most applications additional control devices (timer, temperature-/ power control) are necessary. The study could not give a general answer to whether domestic hot water distribution systems should be heated by heating cables or circulation systems. The best solution depends on the specific building circumstances. Conclusions of the technical and market analysis say that measures in different fields can transfer the saving potentials into practice: architects and designers of sanitary and electrical installations should be informed by articles in specialized magazines: the goal is either to avoid the use of heating cables or to minimize their electricity consumption, training of plumbers and electricians should treat the efficient use of heating cables. An instruction leaflet is to be created. Building owners and operators should be informed by their specialized magazines about problems with heating cables. (author)

  1. Electrically charged matter in rigid rotation around magnetized black hole

    Czech Academy of Sciences Publication Activity Database

    Kovář, J.; Slaný, P.; Cremaschini, C.; Stuchlík, Z.; Karas, Vladimír; Trova, Audrey

    2014-01-01

    Roč. 90, č. 4 (2014), 044029/1-044029/14 ISSN 1550-7998 R&D Projects: GA ČR GB14-37086G Grant - others:GA ČR(CZ) GP14-07753P Institutional support: RVO:67985815 Keywords : black hole s * accretion disks Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.643, year: 2014

  2. New energy storage concept uses tapes

    Science.gov (United States)

    Gruber, A.; Kafesjian, R. R.

    1966-01-01

    Energy storage system uses movable permeable tapes with cathode and electrolyte material that is drawn across an anode to produce electric power. The system features long shelf life, high efficiency, and flexible operation.

  3. Electrical conductivity of short carbon fibers and carbon black-reinforced chloroprene rubber

    International Nuclear Information System (INIS)

    Khoshniat, A. R.; MirAli, M.; Hemmati, M.; Afshar Taromi, F.; Katbab, A.

    2002-01-01

    Elastomers and plastics are intrinsically insulating materials, but by addition of some conductive particles such as conductive carbon black, carbon fibers and metals, they can change to conductive form. Conductivity of these composites are due to formation of the lattices of conductive filler particles in polymer chains. In this report, conductivity of chloroprene rubber filled with carbon black and carbon fibers as a function of temperature and pressure are studied. Electrical conductivity of chloroprene in a function of temperature and pressure are studied. Electrical conductivity of chloroprene in the presence of carbon black with proper mixing conditions increases to the conductivity level of semiconductors and even in the presence of carbon fibers it increases to the level of a conductor material. Meanwhile, the sensitivity of this compound to heat and pressure rises. Thus these composites have found various applications in the manufacture of heat and pressure sensitive sensors

  4. Electrical properties of foamed polypropylene/carbon black composites

    Science.gov (United States)

    Iliev, M.; Kotzev, G.; Vulchev, V.

    2016-02-01

    Polypropylene composites containing carbon black fillers were produced by vibration assisted extrusion process. Solid (unfoamed) composite samples were molded by conventional injection molding method, while structural foams were molded by a low pressure process. The foamed samples were evidenced to have a solid skin-foamed core structure which main parameters were found to depend on the quantity of material injected in the mold. The average bubbles' sizes and their distribution were investigated by scanning electron microscopy. It is established that the conductivity of the foamed samples gradually decreases when reducing the sample density. Nevertheless, the conductivity is found to be lower than the conductivity of the unfoamed samples both being of the same order. The flexural properties of the composites were studied and the results were discussed in the context of the structure parameters of the foamed samples.

  5. Effect of carbon black on electrical and rheological properties of graphite nanoplatelets/poly(ethylene-butyl acrylate composites

    Directory of Open Access Journals (Sweden)

    H. Oxfall

    2015-01-01

    Full Text Available The effect of adding carbon black on the electrical and rheological properties of graphite nanoplatelets/poly(ethylene-butyl acrylate copolymer composites produced via melt or solution mixing was studied. By adding a small amount of low- or high-structured carbon black to the nanocomposite, the electrical percolation threshold decreased and the final conductivity (at higher filler contents increased. The effect on the percolation threshold was significantly stronger in case of the high-structured carbon black where replacing 10 wt% of the total filler content with carbon black instead of graphite nanoplatelets reduced the electrical percolation threshold from 6.9 to 4.6 vol%. Finally, the solution mixing process was found to be more efficient leading to a lower percolation threshold. For the composites containing high-structured carbon black, graphite nanoplatelets and their hybrids there was a quite reasonable correlation between the electrical and rheological percolation thresholds.

  6. Tape dig selv

    DEFF Research Database (Denmark)

    Andersen, Bente Annie Sørine; Neergaard, Christian; Seest, Kristian

    Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives......Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives...

  7. The electrically charged BTZ black hole with self (anti-self) dual Maxwell field

    International Nuclear Information System (INIS)

    Kamata, M.; Koikawa, T.

    1995-04-01

    The Einstein-Maxwell equations with a negative cosmological constant Λ in 2 + 1 spacetime dimensions discussed by Banados, Teitelboim and Zanelli are solved by assuming a self (anti-self) dual equation E r-circumflex = ± B -circumflex , which is imposed on the orthonormal basis components of the electric field E r-circumflex and the magnetic field B -circumflex . This solution describes an electrically charged extra black hole with mass M=8πGQ 2 e , angular momentum J = ±8πGQ 2 e / modul Λ 1/2 and electric charge Q e . Although the coordinate components of the electric field E r and the magnetic field B have singularities on the horizon at r (4πGQ 2 e / modul Λ) 1/2 , the spacetime has the same value of constant negative curvature R = 6Λ as that of Banados et al. (author). 5 refs

  8. Electrically conductive, black thermal control coatings for spacecraft applications. III - Plasma-deposited ceramic matrix

    Science.gov (United States)

    Hribar, V. F.; Bauer, J. L.; O'Donnell, T. P.

    1987-01-01

    Five black, electrically-conductive thermal control coatings have been formulated and tested for application on the Galileo spacecraft. The coatings consist of both organic and inorganic systems applied on titanium, aluminum, and glass/epoxy composite surfaces. The coatings were tested under simulated space environment conditions. Coated specimens were subjected to thermal radiation, convective and combustive heating, and cryogenic conditions over a temperature range between -196 C and 538 C. Mechanical, physical, thermal, electrical, and thermooptical properties are presented for one of these coatings. This paper describes the preparation, characteristics, and spraying of iron titanate on titanium and aluminum, and presents performance results.

  9. Static and rotating electrically charged black holes in three-dimensional Brans-Dicke gravity theories

    OpenAIRE

    Dias, Oscar J. C.; Lemos, Jose' P. S.

    2001-01-01

    We obtain static and rotating electrically charged black holes of a Einstein-Maxwell-Dilaton theory of the Brans-Dicke type in (2+1)-dimensions. The theory is specified by three fields, the dilaton, the graviton and the electromagnetic field, and two parameters, the cosmological constant and the Brans-Dicke parameter. It contains eight different cases, of which one distinguishes as special cases, string theory, general relativity and a theory equivalent to four dimensional general relativity ...

  10. Entropy of an extremal electrically charged thin shell and the extremal black hole

    Directory of Open Access Journals (Sweden)

    José P.S. Lemos

    2015-11-01

    Full Text Available There is a debate as to what is the value of the entropy S of extremal black holes. There are approaches that yield zero entropy S=0, while there are others that yield the Bekenstein–Hawking entropy S=A+/4, in Planck units. There are still other approaches that give that S is proportional to r+ or even that S is a generic well-behaved function of r+. Here r+ is the black hole horizon radius and A+=4πr+2 is its horizon area. Using a spherically symmetric thin matter shell with extremal electric charge, we find the entropy expression for the extremal thin shell spacetime. When the shell's radius approaches its own gravitational radius, and thus turns into an extremal black hole, we encounter that the entropy is S=S(r+, i.e., the entropy of an extremal black hole is a function of r+ alone. We speculate that the range of values for an extremal black hole is 0≤S(r+≤A+/4.

  11. Aligned Carbon Nanotube Tape for Sensor Applications

    Science.gov (United States)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  12. Temperature Coefficients of Electrical Conductivity and Conduction Mechanisms in Butyl Rubber-Carbon Black Composites

    Science.gov (United States)

    Alzamil, M. A.; Alfaramawi, K.; Abboudy, S.; Abulnasr, L.

    2018-02-01

    Electrical properties of butyl rubber filled with General Purpose Furnace (GPF) carbon black were studied. The carbon black concentration ( X) in the compound was X = 40, 60, 70, 80, and 100 parts by weight per hundred parts by weight of rubber (phr). The corresponding volume fractions of GPF carbon black were 0.447 ± 0.022, 0.548 ± 0.027, 0.586 ± 0.029, 0.618 ± 0.031 and 0.669 ± 0.034, respectively. The concentration dependence of conductivity ( σ ) at constant temperature showed that σ follows a percolation theory; σ ∝ ( {X - Xo } )^{γ } , where X o is the concentration at percolation threshold. The exponent γ was found as 6.6 (at room temperature 30°C). This value agrees with other experimental values obtained by many authors for different rubber-carbon black systems. Electron tunneling between the aggregates, which are dispersed in the insulator rubber, was mainly the conduction process proposed at constant temperature in the butyl-GPF carbon black composites. Temperature dependence of conductivity was investigated in the temperature range from 30°C up to 120°C. All samples exhibit negative temperature coefficients of conductivity (NTCC). The values obtained are - 0.130°C-1, - 0.019°C-1, - 0.0082°C-1, - 0.0094°C-1, and - 0.072°C-1 for carbon black concentrations of 40 phr, 60 phr, 70 phr, 80 phr, and 100 phr, respectively. The samples of concentrations 40 phr and 60 phr have also positive temperature coefficients of conductivity (PTCC) of values + 0.031 and + 0.013, respectively. Electrical conduction at different temperatures showed various mechanisms depending on the carbon black concentration and/or the interval of temperature. The hopping conduction mechanism was noticed at the lower temperature region while carrier thermal activation mechanisms were recorded at the higher temperature range.

  13. Physico-mechanical and electrical properties of conductive carbon black reinforced chlorosulfonated polyethylene vulcanizates

    Directory of Open Access Journals (Sweden)

    2008-12-01

    Full Text Available The present work deals with the effect of conductive carbon black (Ensaco 350G on the physico-mechanical and electrical properties of chlorosulfonated polyethylene (CSM rubber vulcanizates. The physico-mechanical properties like tensile strength, tear strength, elongation at break, compression set, hardness and abrasion resistance have been studied before and after heat ageing. Up to 30 parts per hundred rubber (phr filler loading both tensile and tear strength increases beyond which it shows a decreasing trend whereas modulus gradually increases with the filler loading. Incorporation of carbon black increases the hysteresis loss of filled vulcanizates compared to gum vulcanizates. Unlike gum vulcanizate, in filled vulcanizates the rate of relaxation shows increasing trend. The bound rubber content is found to increase with increase in filler loading. Dielectric relaxation spectra were used to study the relaxation behavior as a function of frequency (100 to 106 Hz at room temperature. Variation in real and imaginary parts of electric modulus has been explained on the basis of interfacial polarization of fillers in the polymer medium. The percolation limit of the conductive black as studied by ac conductivity measurements has also been reported.

  14. Magnetization studies of Bi-2223 tapes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, K.H.; Andrikidis, C. [CSIRO, Sydney, NSW (Australia). Division of Applied Physics; Liu, H.K.; Dou, S.X. [University of Wollongong, NSW (Australia). Centre for Superconducting and Electronic Materials

    1996-12-31

    Full text: Superconducting Bi-2223 silver sheathed tapes show a critical current density large enough for power transmission line applications where the magnetic fields involved are small. Unfortunately, the performance of these tapes at 77 K in large fields is quite poor and a better understanding of magnetization data might help to elucidate the reasons for the limitation of the tape`s current carrying capacity. We have investigated by means of magnetic moment measurements on monofilamentary Bi-2223 tapes, using a Quantum Design SQUID magnetometer, the correlation between intergranular critical current density J{sub c}{sup J} which is flowing over the entire tape, and the intragranular critical current density J{sub c}{sup G} which is flowing inside grains. The experimental data reveal that J{sub c}{sup G} depends strongly on the magnetic history of grains and the value of J{sub c}{sup G}. The anomalous peak seen in magnetization loops of tapes correlates well with the peak seen in the critical current density measured electrically in a decreasing magnetic field. The position of the anomalous peak does not shift further to higher fields when the applied field exceeds the field of full grain penetration. By separating the silver cladding from the superconductor we found that, opposite to common believe, the current does not flow mainly near the superconductor-silver interface but is more homogeneously distributed throughout the filament

  15. Formula tape or not

    International Nuclear Information System (INIS)

    Davidson, E.R.; Yoshimine, M.; Dierksen, G.H.F.

    1978-01-01

    Some notes are given on computer calculations of the configuration interaction with the use or nonuse of a formula tape. The cases of the direct, indirect, and general configuration interactions are considered, and the advantages and disadvantages of the formula tape are pointed out, the formula tape being needed for either potential surface calculations or a very long integral list. The Munich molecular program system is described. 3 references

  16. Structural, mechanical and electrical characterization of epoxy-amine/carbon black nanonocomposites

    Directory of Open Access Journals (Sweden)

    2008-05-01

    Full Text Available This work presents an insight into the effect of preparation procedure and the filler content on both electrical and mechanical properties of a nanocomposite system. For the preparation of the nanocomposites diglycidyl ether of bisphenol A (DGEBA was used with triethylenetetramine (TETA as a curing agent. As fillers carbon black (CB nanoparticles with size from 25 to 75 nm were used. The characterization was done using Dynamic Mechanical Analysis (DMA, Dielectric Relaxation Spectroscopy (DRS, Differential Scanning Calorimetry (DSC, Wide Angle X-ray Diffraction (WAXD and electrical conductivity measurements. The dependence of the dynamic mechanical and dielectric parameters (E′, E″, tanδ, ε', ε″, σ and Tg is associated with the filler content and is controlled by the employed curing conditions. An increase in electrical conductivity, which is observed at about 1% w/w of carbon black, indicates the creation of conducting paths and is associated with the Maxwell Wagner Sillars (MWS relaxation, probably due to the formation of aggregated microstructures in the bulk composite..

  17. The electrical properties of epoxy resin composites filled with Cnts and carbon black.

    Science.gov (United States)

    Bellucci, S; Coderoni, L; Micciulla, F; Rinaldi, G; Sacco, I

    2011-10-01

    This work introduces an experimental activity related to the realization of an epossidic nanostructured material that develops the function of covering for electronic circuits in aeronautical field. This covering meets the demand of protection of these circuits from possible troubles of electromagnetic nature. In order to realize this covering we used an epoxy resin as matrix (Epon 828) loaded with conductive nanofillers or carbon nanotubes (Cnts). To check the efficiency of the coating we have considered the carbon black, filler widely used as a conductive covering for screenings. We have considered different percentages of the different fillers, precisely 0.1%, 0.25% and 0.5% wt (% valued in comparison to the weight of the resin). From every mixture 12 samples have been obtained (the size of every sample is 10 mm x 10 mm x 10 mm). Every sample has been subjected to electrical measurements, that have concerned the measurement of current intensity and resistance (so as to allow the evaluation of the enhancement of the conductivity), through the application of different values of voltage. The results have demonstrated that the epoxy matrix loaded with Cnts yields higher values of electrical conductivity than the same matrix loaded with carbon black.

  18. Intrinsic and extrinsic electrical and thermal transport of bulk black phosphorus

    Science.gov (United States)

    Hu, Sile; Xiang, Junsen; Lv, Meng; Zhang, Jiahao; Zhao, Hengcan; Li, Chunhong; Chen, Genfu; Wang, Wenhong; Sun, Peijie

    2018-01-01

    We report a comprehensive investigation of the electrical, thermal, and thermoelectric transport properties of bulk single-crystalline black phosphorus in wide temperature (2-300 K) and field (0-9 T) ranges. Electrical transport below T ≈ 250 K is found to be dominated by extrinsic hole-type charge carriers with large mobility exceeding 104 cm2/V s at low temperatures. While thermal transport measurements reveal an enhanced in-plane thermal conductivity maximum κ = 180 W/m K at T ≈ 25 K, it appears still to be largely constrained by extrinsic phonon scattering processes, e.g., the electron-phonon process, in addition to intrinsic umklapp scattering. The thermoelectric power and Nernst effect seem to be strongly influenced by ambipolar transport of charge carriers with opposite signs in at least the high-temperature region above 200 K, which diminishes the thermoelectric power factor of this material. Our results provide a timely update to the transport properties of bulk black phosphorus for future fundamental and applied research.

  19. Electrical and Tensile Properties of Carbon Black Reinforced Polyvinyl Chloride Conductive Composites

    Directory of Open Access Journals (Sweden)

    Iftekharul Islam

    2018-02-01

    Full Text Available Conductive polymer composites are becoming more important and useful in many electrical applications. This paper reports on the carbon black (CB reinforced polyvinyl chloride (PVC conductive composites. Conductive filler CB was reinforced with thermoplastic PVC by compression molding technique to make conductive composites. The particle size of CB was measured, as it affects the electrical conductivity of the composites. Different types of CB-PVC compression-molded composites were prepared, using CB contents from 5 to 30 wt %. The electrical and tensile properties of these composites were studied and compared. Improved electrical properties were obtained for all CB-PVC conductive polymer composites compared to virgin PVC composite. However, the tensile properties of the CB-PVC composites increased up to 15 wt % CB loading, and then decreased, and elongation at break decreased with increasing CB loading. The structure of the CB, PVC and CB-PVC composites were studied by attenuated total reflection-Fourier transform infrared (ATR-FTIR spectroscopic analysis. ATR-FTIR spectra provide evidence of the formation of CB-PVC composites. The microstructural analyses showed a good dispersion of CB in PVC matrix.

  20. Experiments on Tape

    Science.gov (United States)

    Whitfield, Eddie

    1976-01-01

    The use of science experiments on tape are shown to provide for individual differences from the gifted child to the handicapped in developing skills in the languare art area, developing significant concepts, and making learning come alive. (EB)

  1. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  2. Electrically charged black hole on AdS3 : Scale invariance and the Smarr formula

    Science.gov (United States)

    Erices, Cristián; Fuentealba, Oscar; Riquelme, Miguel

    2018-01-01

    The Einstein-Maxwell theory with negative cosmological constant in three spacetime dimensions is considered. It is shown that the Smarr relation for the electrically charged Bañados-Teitelboim-Zanelli (BTZ) black hole emerges from two different approaches based on the scaling symmetry of the asymptotic behavior of the fields at infinity. In the first approach, we prove that the conservation law associated to the scale invariance of the action for a class of stationary and circularly symmetric configurations, allows to obtain the Smarr formula as long as a special set of holographic boundary conditions is satisfied. This particular set is singled out making the integrability conditions for the energy compatible with the scale invariance of the reduced action. In the second approach, it is explicitly shown that the Smarr formula is recovered through the Euler theorem for homogeneous functions, provided the same set of holographic boundary conditions is fulfilled.

  3. Tape recorder failure investigation

    Science.gov (United States)

    Higgins, M. D.; Loewenthal, S. H.; Carnahan, C. C.; Snyder, G. L.

    1996-01-01

    Two end-item tape recorders lost 4:1 mode data recording mode capability at less than half of their 1 6,000-cycle, 4-year operating life. Subsequent life tests on two spare recorders also experienced 4:1 mode data loss at 8,000 and 11,700 cycles. Tear down inspection after completion of the life tests showed that the tape had worn through the alfesil record and reproduce heads. An investigation was initiated to understand the cause of excessive tape head wear and the reasons why the 4:1 mode data rate, low-speed mode is more damaging than the 1:1 mode data rate, high-speed recording mode. The objective was to establish how operating conditions (tape speed, humidity, temperature, stop/start cycles) affects head life with the goal of extending head life on the remaining in-service tape recorders. Another interest was to explain why an earlier vendor life test showed capability beyond 16,000 cycles.

  4. Electrical and mechanical investigations on polyvinyl chloride filled with haf black

    International Nuclear Information System (INIS)

    El- Nashar, D.E.; Eid, M.A.M.; Abou Aiad, T.H.; Abd-El-Messieh, S.L.

    2005-01-01

    Polyvinyl chloride (PVC) was chosen to be loaded with various amount of high abrasion furnace black (HAF). The mechanical as well as electrical properties of the prepared composites were investigated. The Dielectric properties of these composites were investigated in the frequency range 10 2 - 10 5 Hz at temperature range from 30 to 120 degree C . In addition to the conductivity term, the experimental data of the dielectric losses ε were analyzed using a computer program based on both Havriliak-Nagami and Frohlich equations into two relaxation processes. The first relaxation process in the lower frequency range could be attributed to Maxwell Wagner effect. The second relaxation could be attributed to the combination of the large scale mobilization of the chains i.e. the glass rubber relaxation process in addition to a contribution of the motion of the large aggregates caused by the movement of the main chain, which are expected to be formed by the addition of different ingredients to PVC such as plasticizer. The percolation threshold concentration, which is the concentration after which the conductivity increases many orders of magnitude with very little increase in the filler amount for PVC/HAF composites depends upon the measuring temperature, whether it is below or above the glass transition of the polymer matrix. Stress strain plot, hardness, and other mechanical properties such as stress at yield, stress at rupture, strain at yield, strain at rupture and Young's Modulus were investigated at room temperature. This investigation led to the conclusion that all the mechanical properties are improved by increasing HAF content and reaches its optimum values at about 30 p hr HAF loading. On the other hand. The addition of HAF black by concentration up to 40 p hr increase the electrical conductivity to be in the order of 10 -10 Sm -1 at 30 degree C and 10 -9 Sm -1 at 120 degree C which highly recommend such composites to be used in anti static applications as the

  5. Recording electrophysiological data on video tape: a superior and less costly alternative to conventional tape recorders.

    Science.gov (United States)

    Chiang, R G; Knobloch, C A; Singleton, D M; Steel, C G; Davey, K G

    1985-10-01

    Electrical potentials recorded extracellularly from the sinus gland of the isopod, Oniscus asellus, were stored on video tape with the aid of a digital-audio (DA) processor and a video cassette recorder (VCR). The DA processor transforms the analog signal to digital pulses of equal amplitude and converts these pulses into a television signal for recording on video tape. In playback, the DA processor reconverts the pulses to an analog signal with negligible distortion. When viewed on the oscilloscope screen, electrical potentials reproduced by this method were indistinguishable from electrical potentials recorded 'live' from the sinus gland. However, electrical potentials recorded from the same sinus gland and reproduced by a conventional FM tape recorder were easily differentiated from the 'live' recording. The special effects inherent in the VCR (e.g. stop action, frame advance) also permitted detailed analysis of spontaneously occurring electrical potentials. Special effects were not possible with the FM tape recorder. The price, ease of operation and ability to produce extremely high quality recordings, makes the DA processor and VCR an exceptional system for storing electrophysiological data.

  6. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  7. Magnetic Tape Recording

    Science.gov (United States)

    Athey, Skipwith W.

    1966-01-01

    NASA's contribution to tape recorder technology may appear to lie in such glamorous devices as the tape recorders of the Tiros and Nimbus satellites which receive signals carrying weather information during an orbit around the earth and then transmit those signals back to the ground when the satellite is in view of ground stations. These quite important recording devices are, however, only useful as members of a complex hierarchy of devices all of which participate in the ultimate process of obtaining information from NASA's efforts. Their existence and utility is based on the existence of many more prosaic recording devices which have been involved in the development of such spectacular units.

  8. Recording-tape position sensor

    Science.gov (United States)

    Schoppet, G. C.

    1977-01-01

    Device uses tachometer pulses from capstan and reset pulse from one reel to sense count of tach pulses per revolution of reel. Number of pulses is direct measurement of tape stack radius and is independent of tape speed or direction.

  9. Measurement of black carbon emissions from in-use diesel-electric passenger locomotives in California

    Science.gov (United States)

    Tang, N. W.; Kirchstetter, T.; Martien, P. T.; Apte, J.

    2015-12-01

    Black carbon (BC) emission factors were measured for a California commuter rail line fleet of diesel-electric passenger locomotives (Caltrain). The emission factors are based on BC and carbon dioxide (CO2) concentrations in the exhaust plumes of passing locomotives, which were measured from pedestrian overpasses using portable analyzers. Each of the 29 locomotives in the fleet was sampled on 4-20 separate occasions at different locations to characterize different driving modes. The average emission factor expressed as g BC emitted per kg diesel consumed was 0.87 ± 0.66 g kg-1 (±1 standard deviation, n = 362 samples). BC emission factors tended to be higher for accelerating locomotives traveling at higher speeds with engines in higher notch settings. Higher fuel-based BC emission factors (g kg-1) were measured for locomotives equipped with separate "head-end" power generators (SEP-HEPs), which power the passenger cars, while higher time-based emission factors (g h-1) were measured for locomotives without SEP-HEPs, whose engines are continuously operated at high speeds to provide both head-end and propulsion power. PM10 emission factors, estimated assuming a BC/PM10 emission ratio of 0.6 and a typical power output-to-fuel consumption ratio, were generally in line with the Environmental Protection Agency's locomotive exhaust emission standards. Per passenger mile, diesel-electric locomotives in this study emit only 20% of the CO2 emitted by typical gasoline-powered light-duty vehicles (i.e., cars). However, the reduction in carbon footprint (expressed in terms of CO2 equivalents) due to CO2 emissions avoidance from a passenger commuting by train rather than car is appreciably offset by the locomotive's higher BC emissions.

  10. Electric field modulation of electronic structures in InSe and black phosphorus heterostructure

    Science.gov (United States)

    Ding, Yi-min; Shi, Jun-jie; Zhang, Min; Xia, Congxin; Wu, Meng; Wang, Hui; Cen, Yu-lang; Pan, Shu-hang

    2018-01-01

    The electronic structures of InSe and black phosphorus (BP) heterostructure modulated by an external electric field (E⊥) have been investigated based on first-principles calculations. We find that InSe/BP has type II band offset with a direct band gap of 0.39 eV, and the electrons (holes) are spatially located in InSe (BP) layer. Meanwhile, the band structures of InSe/BP can be effectively modulated by E⊥. The band gap shows linear variation with E⊥ and its maximum of 0.69 eV is observed when E⊥ is 0.4 V / Å. The InSe/BP experiences a transition from semiconductor to metal with E⊥ of -0.6 and 0.8 V / Å. The band offsets are also modulated by E⊥, resulting in different spatial distribution of electron-hole pairs. Most importantly, the high carrier mobility can be preserved well under E⊥. Our results show that the novel InSe/BP heterostructure has great potential application in electronic and optoelectronic devices.

  11. Rheological and electrical properties of hybrid nanocomposites of epoxy resins filled with graphite nanoplatelets and carbon black.

    Science.gov (United States)

    Truong, Quang-Trung; Lee, Seon-Suk; Lee, Dai-Soo

    2011-02-01

    Graphite nanoplatelets (GNP) were prepared by microwave irradiation of natural graphites intercalated with ferric chloride in nitromethane (GIC). Intercalated structure of GIC was confirmed by X-ray diffraction patterns. SEM images of GIC after microwave irradiation showed the exfoliation of GIC, the formation of GNPs. Hybrid nanocomposites of bisphenol-A type epoxy resins filled with GNP and a conductive carbon black (CB) were prepared and rheological and electrical properties of the nanocomposites were investigated. Viscosity and electrical surface resistivity of the nanocomposites showed minima at certain mixtures of GNP and CB in the epoxy resins.

  12. Processing and characterization of a carbon black-filled electrically conductive Nylon-12 nanocomposite produced by selective laser sintering

    International Nuclear Information System (INIS)

    Athreya, Siddharth Ram; Kalaitzidou, Kyriaki; Das, Suman

    2010-01-01

    Selective laser sintering (SLS), a layered manufacturing technique was explored to process an electrically conductive polymer nanocomposite made of Nylon-12 reinforced with 4 wt% of carbon black. SLS process parameters were optimized in order to maximize the flexural modulus. The porosity and morphology were studied using optical microscopy and scanning electron microscopy (SEM). The crystalline state was characterized using differential scanning calorimetry (DSC) and X-ray diffraction (XRD). The electrical conductivity was determined using the four probe technique. Results indicate that carbon black-filled Nylon-12 nanocomposites can be successfully made by SLS. Maximum flexural modulus values of 1750 MPa and 1450 MPa were achieved for the neat polymer and the nanocomposite, respectively. A reduction in the flexural modulus of the nanocomposite is likely due to the formation of a segregated structure in the nanocomposite and a weak polymer-filler interface. The optimized neat polymer and the nanocomposites had average densities of around 97% and 96% relative to full density, respectively. The electrical conductivity of the nanocomposite was approximately 1 x 10 -4 S/cm, which is five orders of magnitude higher than that of the neat polymer processed by SLS, and indicates that the onset of percolation behavior occurs below the 4 wt% loading of carbon black.

  13. Phase structures of the black Dp-D(p+4)-brane system in various ensembles II: electrical and thermodynamic stability

    International Nuclear Information System (INIS)

    Xiao, Zhiguang; Zhou, Da

    2015-01-01

    By incorporating the electrical stability condition into the discussion, we continue the study on the thermodynamic phase structures of the Dp-D(p+4) black brane in GG, GC, CG, CC ensembles defined in our previous paper http://dx.doi.org/10.1007/JHEP07(2015)134. We find that including the electrical stability conditions in addition to the thermal stability conditions does not modify the phase structure of the GG ensemble but puts more constraints on the parameter space where black branes can stably exist in GC, CG, CC ensembles. In particular, the van der Waals-like phase structure which was supposed to be present in these ensembles when only thermal stability condition is considered would no longer be visible, since the phase of the small black brane is unstable under electrical fluctuations. However, the symmetry of the phase structure by interchanging the two kinds of brane charges and potentials is still preserved, which is argued to be the result of T-duality.

  14. Tamper tape seals

    International Nuclear Information System (INIS)

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R ampersand D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique open-quotes fingerprintclose quotes characteristics that can be accessed as desired

  15. Shoulder Taping and Neuromuscular Control.

    Science.gov (United States)

    Snodgrass, Suzanne J; Farrell, Scott F; Tsao, Henry; Osmotherly, Peter G; Rivett, Darren A; Chipchase, Lucy S; Schabrun, Siobhan M

    2018-03-23

      Scapular taping can offer clinical benefit to some patients with shoulder pain; however, the underlying mechanisms are unclear. Understanding these mechanisms may guide the development of treatment strategies for managing neuromusculoskeletal shoulder conditions.   To examine the mechanisms underpinning the benefits of scapular taping.   Descriptive laboratory study.   University laboratory.   A total of 15 individuals (8 men, 7 women; age = 31.0 ± 12.4 years, height = 170.9 ± 7.6 cm, mass = 73.8 ± 14.4 kg) with no history of shoulder pain.   Scapular taping.   Surface electromyography (EMG) was used to assess the (1) magnitude and onset of contraction of the upper trapezius (UT), lower trapezius (LT), and serratus anterior relative to the contraction of the middle deltoid during active shoulder flexion and abduction and (2) corticomotor excitability (amplitude of motor-evoked potentials from transcranial magnetic stimulation) of these muscles at rest and during isometric abduction. Active shoulder-flexion and shoulder-abduction range of motion were also evaluated. All outcomes were measured before taping, immediately after taping, 24 hours after taping with the original tape on, and 24 hours after taping with the tape removed.   Onset of contractions occurred earlier immediately after taping than before taping during abduction for the UT (34.18 ± 118.91 milliseconds and 93.95 ± 106.33 milliseconds, respectively, after middle deltoid contraction; P = .02) and during flexion for the LT (110.02 ± 109.83 milliseconds and 5.94 ± 92.35 milliseconds, respectively, before middle deltoid contraction; P = .06). These changes were not maintained 24 hours after taping. Mean motor-evoked potential onset of the middle deltoid was earlier at 24 hours after taping (tape on = 7.20 ± 4.33 milliseconds) than before taping (8.71 ± 5.24 milliseconds, P = .008). We observed no differences in peak root mean square EMG activity or corticomotor excitability of

  16. Magnetic Tape Recording for the Eighties

    Science.gov (United States)

    Kalil, Ford (Editor)

    1982-01-01

    The practical and theoretical aspects of state-of-the-art magnetic tape recording technology are reviewed. Topics covered include the following: (1) analog and digital magnetic tape recording, (2) tape and head wear, (3) wear testing, (4) magnetic tape certification, (5) care, handling, and management of magnetic tape, (6) cleaning, packing, and winding of magnetic tape, (7) tape reels, bands, and packaging, (8) coding techniques for high-density digital recording, and (9) tradeoffs of coding techniques.

  17. Analysis of pressure sensitive adhesive tape: I. Evaluation of infrared ATR accessory advances

    Science.gov (United States)

    Merrill; Bartick

    2000-01-01

    Attenuated total reflection (ATR), also known as internal reflection spectroscopy (IRS), is a forensically accepted method for infrared (IR) analysis of pressure sensitive adhesive tapes. Advancements of ATR accessories in the last decade have provided the forensic examiner several ATR methods to choose from. These accessories offer a variety of ATR crystal choices with a variety of prices and capabilities. Four different types of pressure sensitive adhesive tapes including duct tape, electrical tape, packaging tape and office tape have been used to compare six different ATR methods. Each of the methods tested offers both benefits and limitaltions which must be considered for the type of sample to be analyze. The intent of this paper is to assist the reader in better understanding ATR techniques, the many differences among currently available ATR accessories and how the method is applied to the analysis of pressure sensitive adhesive tape.

  18. Electrical transport properties of black phosphorus based field-effect transistor with Au/Co/MgO tunneling contacts

    Science.gov (United States)

    Liang, Shiheng; Yang, Huaiwen; Djeffal, Abdelhak; Tao, Bingshan; Mc-Murtry, Stefan; Mangin, Stéphane; Lu, Yuan

    2017-10-01

    Black phosphorus (BP) has recently emerged as a promising two-dimensional direct bandgap semiconducting material. Here, we report the fabrication and the electrical transport measurements of the black phosphorus based field-effect transistor with the Au/Co/MgO as drain and source tunneling contacts. By modulating the back-gate voltage, the multilayer black phosphorus channel exhibits ambipolar characteristics (both n-type and p-type) and the conduction behavior can be switched from hole dominated to electron dominated transport region. In the hole dominated region, we have measured a minimum of Schottky barrier height of 37 meV for Au/Co/MgO contact on BP. Moreover, the transistor ON/OFF (Ion/Ioff) ratio is obtained as large as 107 at 20 K and 105 at 300 K. A systematic study of the temperature and the back-gate voltage dependent conduction properties has been performed to understand the modulation of band structure and the ambipolar behavior. The demonstration of high ON/OFF ratio and low Schottky barrier height by using Au/Co/MgO tunneling contacts reveals a promising potential for spintronics applications with multilayer black phosphorus field-effect transistor.

  19. Teaching with MARC Tapes

    Directory of Open Access Journals (Sweden)

    Pauline Atherton

    1970-03-01

    Full Text Available A computer based laboratory for library science students to use in class assignments and for independent projects has been developed and used for one year at Syracuse University. MARC Pilot Project tapes formed the data base. Different computer programs and various samples of the MARC file (48,POO records, approx. were used for search and retrieval operations. Data bases, programs, and seven different class assignments are described and evaluated for their impact on library education in gen- eral and individual students and faculty in particular.

  20. A terabyte linear tape recorder

    Science.gov (United States)

    Webber, John C.

    1994-01-01

    A plan has been formulated and selected for a NASA Phase 2 SBIR award for using the VLBA tape recorder for recording general data. The VLBA tape recorder is a high-speed, high-density linear tape recorder developed for Very Long Baseline Interferometry (VLBI) which is presently capable of recording at rates up to 2 Gbit/sec and holding up to 1 Terabyte of data on one tape, using a special interface and not employing error correction. A general-purpose interface and error correction will be added so that the recorder can be used in other high-speed, high-capacity applications.

  1. Study of the instability of black slags from electric arc furnace steel industry

    Directory of Open Access Journals (Sweden)

    Frías, M.

    2002-09-01

    Full Text Available In Spain, the steel manufacture produces important quantities of by-products, representing between 15 and 20 % of total steel production. Most by-products are deposited on open air spaces causing serious economical and environmental problems, internationally, different recycling wais are studied, being the main alternative for these by-products as recycled aggregate. The possibility of recycling these by-products in construction sector depends on its possible volume instability because of the presence of some undesirable compounds. In current paper, two different black slags from electric arc furnace steel industry were chemically characterized, paying attention to some well-known compounds by theirs expansion effects, such as: free CaO, free MgO, chlorides and sulphates. The analytical results carried out in the current research detected the presence of insignificant or null amounts of harmful compounds. Therefore, they should not have any negative incidence on phenomena of volume instability.

    En España la fabricación de acero produce grandes cantidades de residuos industriales, las cuales representan entre el 15-20 % de la producción total de acero, en su mayor parte se depositan en vertederos, causando serios problemas económicos y medioambientales a todos los sectores implicados. A nivel internacional, se están estudiando diferentes vías de reutilización, siendo su uso principal como árido de reciclado. La posibilidad de reutilizar estos subproductos industriales en el sector de la construcción se basa en su posible inestabilidad volumétrica, debido a la presencia de ciertos compuestos no deseados. En este trabajo se caracterizan químicamente 2 escorias negras de horno de arco eléctrico con diferente procedencia y se cuantifican algunos de los principales compuestos conocidos por sus efectos expansivos, como: cal libre, magnesia libre, cloruros y sulfatos. Los resultados analíticos de estas dos escorias negras muestran

  2. Tension-Free Vaginal Tape versus Transobturator Tape for ...

    African Journals Online (AJOL)

    Objectives: The transobturator tape (TOT) is based on a similar principle as the tension-free vaginal tape (TVT), but introduced through the obturator foramen. The aim of this study was to compare these slings as surgical procedures for the treatment of stress urinary incontinence (SUI) in women. Patients and Methods: This ...

  3. Aging of magnetic recording tape

    Science.gov (United States)

    Cuddihy, E. F.

    1980-01-01

    The paper deals with a study investigating the nature and rates of the hydrolic aging of a wide-band instrumentation magnetic recording tape which employs oxide and backcoat binders made of a polyester urethane elastomer. It was found that the primary mechanism of tape aging and degradation resulted from hydrolysis of its polyester urethane binder.

  4. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  5. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  6. Centrally managed tapes at DESY

    International Nuclear Information System (INIS)

    Hell, O.

    1994-01-01

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years

  7. Simultaneous obtention of multicomponent ferroalloy and slag from black sands for the development of electrical arc welding consumables

    International Nuclear Information System (INIS)

    Cruz-Crespo, A.; Gomez-Rodriguez, L.; Garcia-Sanchez, L. L.; Quintana-Puchol, R.; Cerpa-Naranjo, A.; Cores-Sanchez, A.

    2004-01-01

    In this paper, chemical and mineralogical characterizations of the black sands of the Mejias placer of Sagua de Tanamo (the most important beach littoral placer of the northwest of oriental Cuba) are exposed. Starting from these characterizations a calculation strategy is developed for the making of the metallurgical load that allows to obtain simultaneously, when processed by carbothermic reduction in an electrical arc furnace, a multicomponent ferroalloy and a useful slag for the making of electric arch welding consumables. The powder of the obtained slag is agglomerated with liquid glass. The resulting pellets, due to their behavior on the submerged arc welding (SAW) present technological and metallurgical properties that correspond with the requirements of an agglomerated flux matrix. The chemical composition of the multicomponent ferroalloy is constituted by metallic elements of high metallurgical and alloyed values (V, Cr, Mo, Ti, Nb). It is appropriate for the formulation of consumables for manual welding (SMAW) and SAW, as well. (Author) 15 refs

  8. Adhesive tape exfoliation

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2015-01-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful....... In particular on the nature of the surprisingly small number of repetitive steps that are needed in order to obtain a single-layer slab. Two frameworks for exfoliation are investigated: parallel exfoliation involving repetitive simultaneous cleaving, the other, serial exfoliation, which involves the repetitive...... cleaving of a single chunk of graphite. For both cases, parallel and serial exfoliation, it is investigated how many generations of cleavages are needed. An approximate model with the probability distribution expressed as a simple closed form is presented and compared with the simulations....

  9. Perceived Benefits of Kinesio Tape® Compared to Non-Kinesiology Tape and No Tape in Healthy Collegiate Athletes

    Directory of Open Access Journals (Sweden)

    Gregory Chown

    2016-10-01

    Full Text Available Background: Sports participation is considered a meaningful occupation for people of all ages. Multiple disciplines use Kinesio Tape® during treatment (Kinesio Taping® Association International, 2013e for sportsrelated injuries. While the use of Kinesio Tape® is becoming increasingly popular in sports, there is a lack of evidence supporting its effectiveness. The purpose of this study was to address the following question: Is there a perceived sports performance benefit of using Kinesio Tape® compared to non-kinesiology tape or no tape in healthy collegiate athletes? Method: This quantitative pilot study used a convenience sampling method. The participants included eighteen healthy men’s and women’s lacrosse players from a division III university. A crossover design was used and consisted of three trials: Kinesio Tape®, non-kinesiology tape, and no tape. Perceived sports performance was measured using an 8-item, study-specific questionnaire. Results: The results indicated that there were no significant differences between the Kinesio Tape® and no tape trials. There were statistically significant differences found between the non-kinesiology tape and no tape trials. Conclusion: While non-kinesiology tape was the only tape that yielded significant differences, the participants perceived their sports performance to be better when wearing either non-kinesiology tape or KT than when wearing no tape, indicating a possible placebo effect.

  10. Effect of polyamide 6 on the morphology and electrical conductivity of carbon black-filled polypropylene composites

    Science.gov (United States)

    Zhang, Xuewei; Liu, Jiang; Wang, Yi; Wu, Wei

    2017-12-01

    Carbon black (CB)-filled polypropylene (PP) with surface resistivity between 106 and 109 Ω sq-1 is the ideal antistatic plastic material in the electronics and electric industry. However, a large amount of CB may have an adverse effect on the mechanical properties and processing performance of the material, thus an improved ternary system is developed. Blends of CB-filled PP and polyamide 6 (PA6) have been prepared by melt blending in order to obtain electrically conductive polymer composites with a low electrical percolation threshold based on the concept of double percolation. The morphological developments of these composites were studied by scanning electron microscopy. The results showed that CB particles were selectively dispersed in PA6 phases due to the good interaction and interfacial adhesion between CB and PA6. At the same CB loadings, the surface resistivity of PP/PA6/CB composite was smaller than that of PP/CB composite system, which indicated the better conductivity in the former composite. The increasing amount of PA6 in the composites changed the morphology from a typical sea-island morphology to a co-continuous morphology. What is more, with 8 wt% of CB and PP/PA6 phase ratio of 70/30 in which the PP and PA6 phases formed a co-continuous structure, the electrical conductivity of the composite peaked at 2.01 × 105 Ω sq-1.

  11. A Numerical Study on Electrical Percolation of Polymer-Matrix Composites with Hybrid Fillers of Carbon Nanotubes and Carbon Black

    Directory of Open Access Journals (Sweden)

    Yuli Chen

    2014-01-01

    Full Text Available The electrical percolation of polymer-matrix composites (PMCs containing hybrid fillers of carbon nanotubes (CNTs and carbon black (CB is estimated by studying the connection possibility of the fillers using Monte Carlo simulation. The 3D simulation model of CB-CNT hybrid filler is established, in which CNTs are modeled by slender capped cylinders and CB groups are modeled by hypothetical spheres with interspaces because CB particles are always agglomerated. The observation on the effects of CB and CNT volume fractions and dimensions on the electrical percolation threshold of hybrid filled composites is then carried out. It is found that the composite electrical percolation threshold can be reduced by increasing CNT aspect ratio, as well as increasing the diameter ratio of CB groups to CNTs. And adding CB into CNT composites can decrease the CNT volume needed to convert the composite conductivity, especially when the CNT volume fraction is close to the threshold of PMCs with only CNT filler. Different from previous linear assumption, the nonlinear relation between CB and CNT volume fractions at composite percolation threshold is revealed, which is consistent with the synergistic effect observed in experiments. Based on the nonlinear relation, the estimating equation for the electrical percolation threshold of the PMCs containing CB-CNT hybrid fillers is established.

  12. Magnetic Neutral Points and Electric Lines of Force in Strong Gravity of a Rotating Black Hole

    Czech Academy of Sciences Publication Activity Database

    Karas, Vladimír; Kopáček, Ondřej; Kunneriath, Devaky

    2013-01-01

    Roč. 3, 3A (2013), s. 18-24 ISSN 2161-4717 R&D Projects: GA ČR(CZ) GC13-00070J Institutional support: RVO:67985815 Keywords : galaxies * nuclei * black hole physics Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics

  13. Role of electric charge in shaping equilibrium configurations of fluid tori encircling black holes

    Czech Academy of Sciences Publication Activity Database

    Kovář, J.; Slaný, P.; Stuchlík, Z.; Karas, Vladimír; Cremaschini, C.; Miller, J. C.

    2011-01-01

    Roč. 84, č. 8 (2011), 084002/1-084002/14 ISSN 1550-7998 R&D Projects: GA MŠk(CZ) LC06014; GA ČR GA205/07/0052 Institutional research plan: CEZ:AV0Z10030501 Keywords : black holes Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 4.558, year: 2011

  14. A Kinetics Study on Electrical Resistivity Transition of In Situ Polymer Aging Sensors Based on Carbon-Black-Filled Epoxy Conductive Polymeric Composites (CPCs)

    Science.gov (United States)

    Liang, Qizhen; Nyugen, Mark T.; Moon, Kyoung-Sik; Watkins, Ken; Morato, Lilian T.; Wong, Ching Ping

    2013-06-01

    Sensors based on carbon-black-filled bisphenol A-type epoxy conductive polymeric composites (CPCs) have been prepared and applied to monitor thermal oxidation aging of polymeric materials. Thermogravimetric analysis (TGA) is applied to characterize weight loss of epoxy resin in the aging process. By using a mathematical model based on the Boltzmann equation, a relationship between the electrical resistivity of the sensors based on epoxy/carbon black composites and aging time is established, making it possible to monitor and estimate the aging status of polymeric components in situ based on a fast and convenient electrical resistance measurement.

  15. String and Sticky Tape Experiments.

    Science.gov (United States)

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  16. Tape Storage and CRC Protection

    CERN Document Server

    Ha, Karel

    2014-01-01

    Over 100 Petabytes of data is stored on several kind of physical support, namely disks and tapes. Data on any physical support or traveling on a data link (network, fibre channel...) can be subject to silent data corruption. A possible improvement is introducing end-to-end data integrity from the filesystem down to the tape layer. For the tape back-end it can be done by using Logical Block Protection, which computes and compares CRC checksum of every single block of data. During my work, I improved on-the-fly CRC calculation for the tape storage system, which was achieved by introducing a multithreaded implementation - a technique applicable to arbitrary CRC algorithm. Finally, I per...

  17. Frequency dependence of electrical properties of polyvinylidene fluoride/graphite electrode waste/natural carbon black composite

    Science.gov (United States)

    Insiyanda, D. R.; Indayaningsih, N.; Prihandoko, B.; Subhan, A.; Khaerudini, D. S.; Widodo, H.; Destyorini, F.; Chaer, A.

    2018-03-01

    Polyvinylidene fluoride (PVdF) is a semi-crystalline thermoplastic material with remarkably high piezoelectric coefficient and an attractive polymer matrix for micro-composite with superior mechanical and electrical properties. The conductive filler is obtained from Graphite Electrode Waste (GEW) and Natural Carbon Black (NCB). The variation of composite content (%) of PVdF/NCB/GEW were 100/0/0, 95/5/0, 95/0/5, 95/2.5/2.5. This experiment employed dry dispersion method for material mixing. The materials were then moulded using hot press machine with compression parameters of P = 5.5 MPa, T = 150 °C, t = 60 minutes, A = 5×5×(0.2 - 0.4) cm3. The electrical conductivity properties of pure PVdF, as well as PVdF/GEW, PVdF/NCB, and PVdF/NCB/GEW composites were investigated in a frequency range of 100 to 100000 Hz. The PVdF/GEW sample obtained the highest electrical conductivity. It is concluded that GEW and NCB can be incorporated into PVdF as a conductive filler to increase the conductivity of conductive material composite without solvent.

  18. El Digital Audio Tape Recorder. Contra autores y creadores

    Directory of Open Access Journals (Sweden)

    Jun Ono

    2015-01-01

    Full Text Available La llamada "DAT" (abreviatura por "digital audio tape recorder" / grabadora digital de audio ha recibido cobertura durante mucho tiempo en los medios masivos de Japón y otros países, como un producto acústico electrónico nuevo y controversial de la industria japonesa de artefactos electrónicos. ¿Qué ha pasado con el objeto de esta controversia?

  19. Continuous tape-recording of ambulatory blood pressure. Technical considerations.

    Science.gov (United States)

    Millar-Craig, M W; Mann, S; Cashman, P M; Raftery, E B

    1981-01-01

    A technique of recording continuous intra-arterial blood pressure in fully ambulatory subjects, on to magnetic tape is described. This method makes use of a specially developed transducer-perfusion unit, which incorporates a strain-gauge pressure transducer and a perfusion system using an electrical "delta" pump. The signal is recorded on cassette tape using a miniature physiological recorder. This recording method has been fully evaluated in the laboratory and has been used clinically on 550 occasions with satisfactory results. Technical limitations and clinical experience of this recording technique are discussed.

  20. Optimization of degradation of Reactive Black 5 (RB5) and electricity generation in solar photocatalytic fuel cell system.

    Science.gov (United States)

    Khalik, Wan Fadhilah; Ho, Li-Ngee; Ong, Soon-An; Voon, Chun-Hong; Wong, Yee-Shian; Yusoff, NikAthirah; Lee, Sin-Li; Yusuf, Sara Yasina

    2017-10-01

    The photocatalytic fuel cell (PFC) system was developed in order to study the effect of several operating parameters in degradation of Reactive Black 5 (RB5) and its electricity generation. Light irradiation, initial dye concentration, aeration, pH and cathode electrode are the operating parameters that might give contribution in the efficiency of PFC system. The degradation of RB5 depends on the presence of light irradiation and solar light gives better performance to degrade the azo dye. The azo dye with low initial concentration decolorizes faster compared to higher initial concentration and presence of aeration in PFC system would enhance its performance. Reactive Black 5 rapidly decreased at higher pH due to the higher amount of OH generated at higher pH and Pt-loaded carbon (Pt/C) was more suitable to be used as cathode in PFC system compared to Cu foil and Fe foil. The rapid decolorization of RB5 would increase their voltage output and in addition, it would also increase their V oc , J sc and P max . The breakage of azo bond and aromatic rings was confirmed through UV-Vis spectrum and COD analysis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Comparison of recording properties of ME tape and thin MP tape with respect to overwrite behavior

    OpenAIRE

    Lalbahadoersing, S.; Groenland, J.P.J.; Luitjens, S.B.; Lodder, J.C.

    1997-01-01

    Differences between the recording characteristics of thin MP and ME tape are studied. The effect of the thickness reduction of MP tape is also investigated. When thin MP tape (with thickness 140 nm) is compared with ME tape (with thickness 150 nm), we observe a better signal and overwrite response for the ME tape. Through simulations the influence of an easy axis out-of-plane and a different reversal mechanism in ME tape is related to overwrite behavior.

  2. Electricity pylons may be potential foci for the invasion of black cherry Prunus serotina in intensive farmland

    Science.gov (United States)

    Kurek, Przemysław; Sparks, Tim H.; Tryjanowski, Piotr

    2015-01-01

    Electricity pylons are used by birds for nesting platforms, song posts, roosting, perching and therefore as defecation sites. Consequently we predict that pylons may facilitate the dispersal of endozoochorous plants, such as black cherry Prunus serotina, an invasive species in Europe producing fruits that are often eaten by birds. To test the influence of electricity pylons on the abundance of P. serotina in farmland in western Poland we surveyed 124 areas under pylons and 124 paired control plots within fields under power lines. P. serotina occurred under 81.5% of the investigated pylons but only in 2.4% of the control plots. The vast majority of P. serotina plants occurred under pylons (99.9% of 5820 individuals) of which only 0.7% (42 individuals), found under 12 pylons, were fruiting. The few plants in control plots were all seedlings. The density of plants was related to landscape variables; the occurrence of P. serotina was higher when pylons were situated within arable crops, had a lower level of herb cover and were closer to human settlements. These results suggest that one approach to protect semi natural or even anthropogenic landscapes from exotic and invasive species is by encouraging permanent land use involving some form of annual disturbance, such as hay cutting or ploughing.

  3. Tuning the electrical and optical anisotropy of a monolayer black phosphorus magnetic superlattice

    Science.gov (United States)

    Li, X. J.; Yu, J. H.; Luo, K.; Wu, Z. H.; Yang, W.

    2018-04-01

    We investigate theoretically the effects of modulated periodic perpendicular magnetic fields on the electronic states and optical absorption spectrum in monolayer black phosphorus (phosphorene). We demonstrate that different phosphorene magnetic superlattice (PMS) orientations can give rise to distinct energy spectra, i.e. tuning the intrinsic electronic anisotropy. Rashba spin-orbit coupling (RSOC) develops a spin-splitting energy dispersion in this phosphorene magnetic superlattice. Anisotropic momentum-dependent carrier distributions along/perpendicular to the magnetic strips are demonstrated. The manipulations of these exotic electronic properties by tuning superlattice geometry, magnetic field and the RSOC term are addressed systematically. Accordingly, we find bright-to-dark transitions in the ground-state electron-hole pair transition rate spectrum and the PMS orientation-dependent anisotropic optical absorption spectrum. This feature offers us a practical way of modulating the electronic anisotropy in phosphorene by magnetic superlattice configurations and detecting this modulation capability by using an optical technique.

  4. Beyond black lung: scientific evidence of health effects from coal use in electricity generation.

    Science.gov (United States)

    Buchanan, Susan; Burt, Erica; Orris, Peter

    2014-08-01

    While access to electricity affects health positively, combustion of coal in power plants causes well-documented adverse health effects. We review respiratory, cardiovascular, reproductive, and neurologic health outcomes associated with exposure to coal-fired power plant emissions. We also discuss population-level health effects of coal combustion and its role in climate change. Our review of scientific studies suggests that those we present here can be used to inform energy policy.

  5. California Black Rail - Central Delta [ds17

    Data.gov (United States)

    California Department of Resources — Results of taped-call black rail surveys of in-stream habitat within certain waterways in the central Sacramento / San Joaquin Delta during 1992 and 1993. TIME...

  6. Tape edge study in a linear tape drive with single-flanged guides

    Energy Technology Data Exchange (ETDEWEB)

    Goldade, A.V.; Bhushan, Bharat E-mail: bhushan.2@osu.edu

    2004-05-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge.

  7. Tape edge study in a linear tape drive with single-flanged guides

    International Nuclear Information System (INIS)

    Goldade, A.V.; Bhushan, Bharat

    2004-01-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge

  8. Superconducting flat tape cable magnet

    Science.gov (United States)

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  9. Smarr formula for black holes endowed with both electric and magnetic charges

    Science.gov (United States)

    Manko, V. S.; García-Compeán, H.

    2018-03-01

    The present paper clarifies how to consistently take into account the contribution of magnetic charges in the generalized Smarr mass formula by using properly Tomimatsu’s representation of Komar integrals. It is shown in particular that in all three examples of dyonic solutions considered by us, the sum of the two electromagnetic terms in Smarr’s formula can be cast into the form \\bar{{\\mathcal Q}}Φ^H_ext , where {{\\mathcal Q}} is the complex charge and Φ^H_ext the complex extension of the electric potential.

  10. Sharpen Your Skills: Tape Recording.

    Science.gov (United States)

    Perry, Helen

    1983-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives guidelines for transcribing special formats such as typing books. The second article tells how to give verbal instructions for diagraming sentences and other…

  11. Comparison of recording properties of ME tape and thin MP tape with respect to overwrite behavior

    NARCIS (Netherlands)

    Lalbahadoersing, S.; Groenland, J.P.J.; Luitjens, S.B.; Lodder, J.C.

    1997-01-01

    Differences between the recording characteristics of thin MP and ME tape are studied. The effect of the thickness reduction of MP tape is also investigated. When thin MP tape (with thickness 140 nm) is compared with ME tape (with thickness 150 nm), we observe a better signal and overwrite response

  12. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15?h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ank...

  13. The influence of pulsed electric fields and microwave pretreatments on some selected physicochemical properties of oil extracted from black cumin seed.

    Science.gov (United States)

    Bakhshabadi, Hamid; Mirzaei, HabibOllah; Ghodsvali, Alireza; Jafari, Seid Mahdi; Ziaiifar, Aman Mohammad

    2018-01-01

    Application of novel technologies such as microwave and pulsed electric fields (PEF) might increase the speed and efficiency of oil extraction. In the present research, PEF (3.25 kV/cm electric field intensity and 30 pulse number) and microwave (540 W for 180 s) pretreatments were used to study the process of oil extraction from black cumin ( Nigella sativa ) seeds. After applying the selected pretreatments, the oil of seeds was extracted with the use of a screw press and the extraction efficiency, refractive index, oil density, color index, oxidative stability, and chemical components of oil and protein of meal were evaluated. The achieved results expressed that PEF and microwave pretreatments increased the oil extraction efficiency and its oxidative stability. Different pretreatments didn't have any significant influence on the refractive index of black cumin seed oil ( p >.05). When microwave and PEF were used, the oil density showed an enhancement as the following: 1.51% and 0.96%, respectively in comparison with the samples with no pretreatments. Evaluation of the extracted oils, using GC/MS analysis indicated that thymoquinone was the dominant phenolic component in the black cumin oil. Finally, the SEM analysis revealed that microwave and PEF can be useful in the extraction of oil from black cumin seeds since these treatments damaged cell walls and facilitated the oil extraction process.

  14. Analisis Perilaku Konsumen Proll Tape di Jember

    OpenAIRE

    Kusmiati, Ati; Widjayanti, Lenny; Risaldi, Feri

    2009-01-01

    Proll tape is a agroindustrial product which used agriculture product as a basic material. It is a diversification product from tape and mixed with some flavour. It can be found in the gift store. Proll tape marketing strategic will influence consumer behaviour in the decision buying. Consumer buy proll tape as a gift as beside on their own consumption. Consumer considers proll tape has a good quality so that it can fill consumer needed. Purpose of the research to find out the influence facto...

  15. Effect of tape recording on perturbation measures.

    Science.gov (United States)

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  16. The Effect of Kinesio Taping on Anterior Knee Pain Consistent With Patellofemoral Pain Syndrome: A Critically Appraised Topic.

    Science.gov (United States)

    Campbell, Samantha A; Valier, Alison R

    2016-08-01

    Patellofemoral pain syndrome (PFPS) occurs in 25% of adolescents and adults and is the leading cause of knee pain in runners. Pain is commonly felt when ascending or descending stairs, deep squatting, kneeling, or running. There is no consensus on the etiology of this condition, but insufficient hip strength, malalignment of the lower extremity, hyperpronation of the foot, and patellar incongruence have been suggested. Common treatments of PFPS include strengthening of quadriceps and hip muscles, McConnell taping, electrical stimulation, and foot orthotics, but effectiveness of these treatments is inconclusive. Kinesio Taping is an alternative taping technique for musculoskeletal injuries including PFPS. Although research suggests that Kinesio Taping decreases pain and improves range of motion for some musculoskeletal injuries, its effectiveness in decreasing pain in patients with PFPS in unknown. Furthermore, Kinesio Taping has not been compared with other taping techniques including McConnell taping. Focused Clinical Question: For patients with anterior knee pain consistent with PFPS, does treatment with Kinesio Taping decrease pain more than McConnell taping or no tape at all?

  17. The neutron beam users tape management system

    International Nuclear Information System (INIS)

    Lyall, B.; Johnson, M.W.

    1977-02-01

    Systems are described for dealing with data collected at the High Flux Reactor, Institut Laue-Langevin, Grenoble and brought on magnetic tape to the Neutron Beam Research Unit at the Rutherford Laboratory. The first system, named GNAT, was designed to archive the incoming 800 bpi tapes onto 6250 bpi tapes (to enable them to return to the ILL). The archiving program, besides choosing the archive tapes, keeping a record of the data sets archived, and writing the archive tape, should be able to cope with incoming tapes whose formats are somewhat different from the standard IBM format. The second system, named FONT, was designed to maintain a record of all the tapes in the NBRU's possession, their whereabouts and what data, if any, are on them. (U.K.)

  18. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  19. Pinning Mechanisms in YBCO Tapes

    CERN Document Server

    Spera, Marcello; Ballarino, Amalia

    2015-01-01

    In this thesis work, a study on flux pinning mechanisms of commercial YBCO tapes is presented. This study has been performed via critical current characterization using transport (via direct I-V curves) and magnetization (via a Vibrating Sample Magnetometer) measurements. The latter ones turned out to be better concerning the comprehension of the pinning landscape of the provided samples, as a wider range of magnetic fields and temperatures is available for those measurements in the setup I used. The comparison of the experimental data with existing theoretical models allowed me to draw a picture of the pinning mechanisms underlying in each sample, and they turned out to be quite different one another. Moreover, for high-performance research tapes, another interesting feature has been found: the counterplay between the self-field critical current and the in-field one. Very well engineered artificial pinning structures limit the self-field critical current density due to the hi...

  20. Multilingual health education tapes project.

    Science.gov (United States)

    Vryheid, R

    1992-01-01

    The success of Thailand's 1985 malaria education cassette tapes project motivated the Highland Development Program to produce tapes in 6 tribal languages on family planning, maternal and child health, nutrition, and disease prevention. Staff produced tapes using a drama or radio magazine format as a series of short features with music and sound effects. Scriptwriters consulted villagers, broadcasting professionals, research workers, and health officials to tailor messages to the various hill tribes. They tried to avoid conflict between traditional and modern concepts and to minimize distrust of government services. The scriptwriters used basically short, grammatically simple sentences, and colloquial Thai to simplify translation. The staff tried to recruit literate, adult, native speakers of the target languages with some experience in health education in their own languages. Obstacles encountered with translation included some languages used an uncommon alphabet or translators did not know their own alphabet. The program backtranslated the scripts to assure the accuracy of the messages and the appropriateness of the words used. Backtranslation revealed deficiencies in the translated messages. Altering the meaning of technical terms tended to be simple mistakes, words with multiple meanings, and exaggeration of problems and/or solutions. Translators also sometimes failed to adapt cultural ideas to those of their tribes. For example, some persons translated all possible misconceptions about a disease yet the tribes did not have all the misconceptions. As of early 1992, recording, pretesting, distribution, and follow up had not yet taken place. The staff should meet with a recording studio to coordinate production including technicians and translators identifying means to communicate. Staff should be aware of signs of poor translation which they may have missed earlier and surfaces during recording. Pretesting should occur among literate and illiterate members of

  1. Scan rate converter for tape recording and playback of TV pictures

    Science.gov (United States)

    Holt, N. I.

    1968-01-01

    Magnetic tape recording and playback equipment converts television pictures, both black and white and color, from one scan rate to another. The equipment indexes color picture frames for retrieval electronically and can be used as a document storage and retrieval medium that is compatible with hard-copy printout machines.

  2. Hygroscopic properties of magnetic recording tape

    Science.gov (United States)

    Cuddihy, E. F.

    1976-01-01

    Relative humidity has been recognized as an important environmental factor in many head-tape interface phenomena such as headwear, friction, staining, and tape shed. Accordingly, the relative humidity is usually specified in many applications of tape use, especially when tape recorders are enclosed in hermetically sealed cases. Normally, the relative humidity is believed regulated by humidification of the fill gas to the specification relative humidity. This study demonstrates that the internal relative humidity in a sealed case is completely controlled by the time-dpendence of the hygroscopic properties of the pack of magnetic recording tape. Differences are found in the hygroscopic properties of the same brand of tape, which apparently result from aging, and which may have an effect on the long-term humidity-regulating behavior in a sealed case, and on the occurrence of head-tape interface phenomena from the long-term use of the tape. Results are presented on the basic hygroscopic properties of magnetic tape, its humidity-regulating behavior in a sealed case, and a theoretical commentary on the relative humidity dependence of head-wear by tape, is included.

  3. Perceived Benefits of Kinesio Tape® Compared to Non-Kinesiology Tape and No Tape in Healthy Collegiate Athletes

    OpenAIRE

    Gregory Chown; Jennifer Innamorato; Marlee McNerney; Jennifer Petrilla; Hillary Prozzillo

    2016-01-01

    Background: Sports participation is considered a meaningful occupation for people of all ages. Multiple disciplines use Kinesio Tape® during treatment (Kinesio Taping® Association International, 2013e) for sportsrelated injuries. While the use of Kinesio Tape® is becoming increasingly popular in sports, there is a lack of evidence supporting its effectiveness. The purpose of this study was to address the following question: Is there a perceived sports performance benefit of using ...

  4. Chemical fingerprinting of adhesive tapes by GCMS detection of petroleum hydrocarbon products.

    Science.gov (United States)

    Aziz, Nurhuda; Greenwood, Paul F; Grice, Kliti; John Watling, R; van Bronswijk, Wilhelm

    2008-09-01

    Pressure-sensitive adhesive tapes often represent key evidence of crimes such as assault, rape or homicide; thus, the development of analytical techniques able to contribute to a detailed characterization of these materials is of forensic importance. The gas chromatography-mass spectrometry (GCMS) analysis of the solvent extractable fractions of a suite of electrical and gaffer adhesive tapes spanning a range of colors and manufacturers identified a number of petroleum-derived hydrocarbons. Molecular and isotopic analyses of hydrocarbon constituents of complex materials have found wide analytical utility including the forensic investigation of oil spills and arson. Here, we investigate the utility of these techniques for characterizing the hydrocarbon composition of pressure-sensitive adhesive tapes for forensic correlation purposes. Subtle distinction of tape samples was evident in the GCMS distribution of several hydrocarbon groups including alkyl-naphthalenes, hopane and sterane biomarkers. Linear discriminant analysis of the abundances of these products provided high level differentiation of tape manufacturer. The distinction of different adhesive tape samples was further extended by measurement of their stable carbon isotopic values. The molecular and isotopic differences of the petroleum content of tapes are consistent with the use of different petroleum materials used in the manufacturing process and demonstrate the benefits of the combined use of complementary oil hydrocarbon characterization approaches. This study reveals the forensic potential of using established petroleum characterization methods for characterizing materials with a petroleum-derived hydrocarbon element.

  5. Electricity

    Indian Academy of Sciences (India)

    AC power generation, its transmission and distribution. The well known observations made by Oersted that an electric current produces a magnetic field led a number of researchers to investigate whether the converse was true i.e. whether electric current can be produced from a magnetic field. Michael Faraday of England ...

  6. Evaluation of a strengthening and insulation system for high temperature BSCCO-2223 superconducting tape

    Energy Technology Data Exchange (ETDEWEB)

    King, C.; Mantone, A. [GE Medical Systems, Florence, SC (United States); Herd, K.; Laskaris, T. [GE Corp. Research and Development Center, Schenectady, NY (United States)

    1995-12-31

    Recent advances in BSCCO-2223 superconducting tape quality and length have led to demonstration programs for coil performance. The conductors in these coils need to be insulated without damage to the superconducting properties. A paper insulation process developed at the General Electric Company (GE) for low temperature superconducting Nb{sub 3}Sn tape has been modified to provide the same insulation system to high temperature (HTS) superconducting tapes, such as BSCCO-2223. In this paper, we report on the insulation process and its effect on the tape performance. Several long lengths of conductor have been tested, unwound, insulated and retested to examine any degradation issues. Additionally, it is known that HTS materials are inherently weak in relation to the winding and handling stresses in a manufacturing environment. A system to provide mechanical stabilization to Nb{sub 3}Sn tape through a lamination process has been successfully applied to high temperature superconductors as a method to build a strong, windable composite. The system is described and mechanical and electrical properties of the strengthened tapes are discussed.

  7. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  8. Developments in research on tape media

    NARCIS (Netherlands)

    Groenland, J.P.J.; Lodder, J.C.

    2001-01-01

    Magnetic tape storage is shown to be a relatively inexpensive technology for backup, archival and distribution of digital data. Metal evaporated (ME) tape provides a remarkable good recording performance being expressed in its favorable frequency spectrum and overwrite behaviour. However, recording

  9. Weld Strength Assessment for Tape Placement

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Akkerman, Remko; Wijskamp, Sebastiaan; Kok, J.S.M.

    2010-01-01

    A mandrel peel set-up is developed to assess the peel fracture toughness of fibre reinforced thermoplastic tapes welded on a woven laminate using a laser-assisted tape placement robot. A comprehensive experimental programme was designed to investigate the influence of nip point temperature and

  10. Data analysis of event tape and connection

    International Nuclear Information System (INIS)

    Gong Huili

    1995-01-01

    The data analysis on the VAX-11/780 computer is briefly described, the data is from the recorded event tape of JUHU data acquisition system on the PDP-11/44 computer. The connection of the recorded event tapes of the XSYS data acquisition system on VAX computer is also introduced

  11. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  12. High Voltage Breakdown, Partial Discharge and Aging in Lapped Tape Insulated Cold Dielectric Model Cables

    Science.gov (United States)

    Sauers, I.; James, D. R.; Pace, M. O.; Ellis, A. R.; Muller, A. C.

    2004-06-01

    High temperature superconducting (HTS) power cables generally follow either of two generic designs, cold dielectric and warm dielectric. In the cold dielectric design, lapped tape insulation and liquid nitrogen are used in combination to provide the electrical insulation between the conductor and the ground shield of an HTS cable. Lapped tape insulated model cables have been tested at high voltage, including AC breakdown, negative impulse breakdown, partial discharge, and long term aging under AC stress. Tapes tested include Cryoflex™ (a proprietary tape developed by Southwire) and PPLP® (a commercial semi synthetic tape). Two high voltage cryostats have been built for short and long term aging studies that permit testing of model cables under the combined conditions of high electric stress, cryogenic temperature and elevated pressures up to 15 bar. For the aging studies, a log-log plot of electric stress versus time-to-breakdown has yielded an estimate of cable lifetime. Since aging at cryogenic temperatures is not expected to have a thermal cause, dielectric wear in HTS cables reduces to partial discharge as the primary aging mechanism. Phase and amplitude resolved partial discharge data of model cables in liquid nitrogen will be presented.

  13. The Galileo Tape Recorder Rewind Operation Anomaly

    Science.gov (United States)

    Johnson, Michael R.; Levanas, Greg C.

    1997-01-01

    On October 11, 1995, the Galileo spacecraft executed a sequence to record three approach images of Jupiter on the spacecraft's tape recorder, rewind the tape, and play back the images at the appropriate data rate consistent with the downlink performance. The recording of the images was performed and the spacecraft computer commanded the tape recorder to rewind the tape to the beginning of the first image. The rewind command was started at the proper time but the tape never got to the beginning of the image data. The analyses and tests that followed allowed a conclusive determination of the failure mechanism and indicated a strategy that could be used to prevent the untimely demise of the mission.

  14. Engineering a bacterial tape recorder.

    Science.gov (United States)

    Prokup, Alexander; Deiters, Alexander

    2015-05-04

    A method has been developed to produce and integrate single-stranded DNA into genomic locations in bacteria in response to exogenous signals. The system functions similarly to a cellular tape recorder by writing information into DNA and reading it at a later time. Much like other cellular memory platforms, its operation is based on DNA recombinase function. However, the scalability and recording capacity have been improved over previous designs. In addition, memory storage was reversible and could be recorded in response to analogue inputs, such as light exposure. This modular memory writing system is an important addition to the genomic editing toolbox available for synthetic biology. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Interactions at the head-tape interface of a linear tape system

    International Nuclear Information System (INIS)

    Wild, M.A.

    2001-08-01

    Many of the recent improvements in the capacity of data cartridge systems have been achieved through the use of narrower tracks, higher linear densities and continuous servo tracking with multi-channel heads. These changes have produced new tribological problems at the head/tape interface. It is crucial that the tribology of such systems is understood and this will continue since increasing storage capacities and faster transfer rates are constantly being sought. Chemical changes in the surface of single and dual layer MP tape have been correlated to signal performance. An accelerated tape tester, consisting of a custom made cycler ( l oop tester ) , was used to ascertain if results could be produced that were representative of a real tape drive system. A second set of experiments used a modified tape drive (Georgens cycler), which allowed the effects of the tape transport system on the tape surface to be studied. To isolate any effects on the tape surface due to the head/tape interface, read/write heads were not fitted to the cycler. Two further sets of experiments were conducted which included a head in the tape path. This allowed the effects of the head/tape interface on the physical and chemical properties of the head and tape surfaces to be investigated. It was during the final set of experiments that the effect on the head/tape interface, of an energised MR element, was investigated. The effect of operating each cycler at extreme relative humidity and temperature was investigated through the use of an environmental chamber. Extensive use was made of surface specific analytical techniques such as XPS, AFM, AES and SEM to study the physical and chemical changes that occur at the head/tape interface. Results showed that cycling improved the signal performance of all the tapes tested. The data cartridge drive belt had an effect on the chemical properties of the tape surface on which it was in contact. Also binder degradation occurred for each tape and appeared to

  16. Electromechanical characterization of superconducting wires and tapes at 77 K

    CERN Document Server

    Bjoerstad, Roger

    The strain dependency of the critical current in state-of-the-art cuprate high-temperature superconductors (HTS) has been characterized. A universal test machine (UTM) combined with a critical current measurement system has been used to characterize the mechanical and the superconducting properties of conductors immersed in an open liquid nitrogen dewar. A set-up has been developed in order to perform simultaneous measurements of the superconductor lattice parameter changes, critical current, as well as the stress and strain at 77 K in self-field in a high energy synchrotron beamline. The HTS tapes and wires studied were based on YBCO, Bi-2223 and Bi-2212. The YBCO tapes were produced by SuperPower and American Superconductors (AMSC). Two types of Bi-2223 tapes, HT and G, were produced by Sumitomo Electric Industries (SEI). The Bi-2212 wires were produced by Oxford Superconducting Technology (OST) using Nexans granulate precursor, before undergoing a specialized over pressure (OP) processing and heat treatmen...

  17. White House Tapes of the Nixon Administration, 1971 to 1973

    Data.gov (United States)

    National Archives and Records Administration — This dataset provides information about the Nixon Administration's White House Tapes. The White House Tapes contain sound recordings of President Richard Nixon's...

  18. Electricity

    Indian Academy of Sciences (India)

    which removes the heat produced In the core and the colis. I represents an Isolator which is a kind of. 'switch' used to isolate the station from the grid. Note the huge Insulators (marked I) that are used. The steel structures marked S support the conductors through insulators (courtesy: Kirloskar Electric Company, Bangalore).

  19. AC Losses in Bi2Sr2Ca2Cu3O10+x Tapes and a 3.15-m-Long Single-Phase Cable

    DEFF Research Database (Denmark)

    Juul, Jeppe; Mølgaard, Ebsen T.; Jensen, Jens

    2011-01-01

    The alternating-current losses in superconducting multifilament BiSCCO-2223 tapes and a 3.15-m single-phase test cable were measured at 77 K using an electrical transport method. The cable had an inner diameter of 42 mm; it was composed of a single layer of 31 multifilament tapes and had a critic...

  20. Stray field interaction of stacked amorphous tapes

    International Nuclear Information System (INIS)

    Guenther, Wulf; Flohrer, Sybille

    2008-01-01

    In this study, magnetic cores made of amorphous rectangular tape layers are investigated. The quality factor Q of the tape material decreases rapidly, however, when stacking at least two tape layers. The hysteresis loop becomes non-linear, and the coercivity increases. These effects are principally independent of the frequency and occur whether tape layers are insulated or not. The Kerr-microscopy was used to monitor local hysteresis loops by varying the distance of two tape layers. The magnetization direction of each magnetic domain is influenced by the anisotropy axis, the external magnetic field and the stray field of magnetic domains of the neighboring tape layers. We found that crossed easy axes (as the extreme case for inclined axes) of congruent domains retain the remagnetization and induce a plateau of the local loop. Summarizing local loops leads to the observed increase of coercivity and non-linearity of the inductively measured loop. A high Q-factor can be preserved if the easy axes of stacked tape layers are identical within the interaction range in the order of mm

  1. Use of tape-recorded food records in assessing children's dietary intake.

    Science.gov (United States)

    Lindquist, C H; Cummings, T; Goran, M I

    2000-01-01

    Dietary assessment among children is particularly problematic when techniques are dependent on memory skills or advanced cognitive development. The current study explored the use of self-report by tape recorders to document children's dietary intake immediately upon consumption, and compared this method with the traditional, interviewer-guided recall technique. In addition, the influence of body fatness and sociodemographic characteristics on the accuracy of recall and tape-recorded food records was determined. The sample included 30 black and white children aged 6.5 to 11.6 years (x = 9.5). Energy intake (EI), measured by six 24-hour food records (three for each method), was compared with total energy expenditure calculated by the doubly labeled water technique. Paired t tests, correlation analyses, and multiple regression analyses were performed. The analyses revealed poor validity of the tape recorder method (x misreporting score = -1.13+/-2.62 MJ/day, r for total energy expenditure and EI = -0.06, p = 0.74). Estimates of EI differed significantly between the tape recorder and recall methods (ptape recorder method. The results suggest that the use of the tape recorder for estimating EI does not result in accurate assessments among children, although this technique may be useful for specific subgroups (i.e., younger and leaner children).

  2. Measuring transport current loss of BSCCO/Ag tapes exposed to external AC magnetic field

    NARCIS (Netherlands)

    Rabbers, J.J.; ten Haken, Bernard; ten Kate, Herman H.J.

    1998-01-01

    BSCCO/Ag tape superconductors are developed for electrical power applications at liquid nitrogen temperatures. In these applications, e.g., superconducting transformers and power cables, an AC transport current and an AC magnetic field are present at the same time. A set-up to measure the influence

  3. Tape Cassette Bacteria Detection System

    Science.gov (United States)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  4. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    OpenAIRE

    Biju Chetri; U.T. Ifthikar Ali; Madhusmita Koch; Abhijit Dutta

    2016-01-01

    Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected...

  5. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... pubic hair line. A special man-made (synthetic mesh) tape is passed through the cut inside the ... West Bloomfield, MI. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Medical ...

  6. Light-Curing Adhesive Repair Tapes

    Science.gov (United States)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  7. Structural modeling of HTS tapes and cables

    Science.gov (United States)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2016-12-01

    Structural finite element analysis (FEA) has been used as an insightful tool to investigate the electromechanical behavior of HTS REBCO tapes and twisted stacked-tape cables under tension, torsion, bending and combined loads. A novel technique was developed for modeling the layered composite structure of the 2G tapes with structural solid-shell elements in ANSYS®. The FEA models produced detailed strain information for the REBCO superconducting layer which was then paired with an analytical model to predict the critical current performance of the 2G HTS tapes under various loads. Two commercially available HTS tapes (SuperPower and SuNAM) under tension, torsion and combined tension-torsion were first analyzed with FEA and compared with available experimental results at 77 K. A sharp critical current degradation was experienced at the yield strength of the tapes under tension and below a 100 mm twist-pitch under torsion. Combined tension-torsion loads had a more gradual degradation of critical current for twist-pitches of 115 mm or shorter but had a negligible difference compared to pure tension for longer twist-pitches. Using the structural solid-shell technique for modeling 2G tapes in ANSYS®, an FEA methodology for simulating full scale three-dimensional HTS stacked-tape cables under pure bending was created. A model of a Twisted-Stacked Tape Cable (TSTC), a configuration first proposed at MIT, was initially developed and then adapted to the slotted-core HTS Cable-In-Conduit Conductor produced by the ENEA laboratory in Italy. The numerical axial strain of the HTS REBCO tapes within the cables as calculated by FEA were found to agree with an analytical model for two cases: perfect-slip (frictionless) and no-slip (bonded). The ENEA CICC model was also compared with recent experimental critical current data at 77 K and was found to match best using a low friction coefficient of 0.02 indicating that the tapes within the cable freely slide with respect to each other

  8. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the S...

  9. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    Directory of Open Access Journals (Sweden)

    Biju Chetri

    2016-04-01

    Full Text Available Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected. The subjects were randomly divided into two groups i.e. Group A and Group B. Group A received taping, iontophoresis with plantar fascia stretching. Group B received taping and plantar fascia stretching. A total of 6 treatment sessions were given on alternate days over a period of two weeks for both the groups. Results: VAS and FFI scores across baseline and post intervention showed a significant improvement statistically in their mean scores between Groups A and B (P<0.05. Between group comparison of VAS and FFI scores, it showed that subject treated with Iontophoresis in combination with taping and plantar fascia stretch (Group A had significant improvement in VAS and functional ability when compared to subjects treated with taping and plantar fascia stretching alone (Group B. Conclusion: Iontophoresis along with Taping and plantar fascia stretching gave an additional benefit when compared with Taping and plantar fascia stretching alone in reducing pain and improving function in plantar fasciitis.

  10. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Chihaya, E-mail: chihaya.kurihara@jp.fujikura.com [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka [Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I{sub c} measurement, we found that our new multi-filamentary tape could provide almost equal I{sub c} compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  11. Black hole levitron

    International Nuclear Information System (INIS)

    Arsiwalla, Xerxes D.; Verlinde, Erik P.

    2010-01-01

    We study the problem of spatially stabilizing four dimensional extremal black holes in background electric/magnetic fields. Whilst looking for stationary stable solutions describing black holes placed in external fields we find that taking a continuum limit of Denef et al.'s multicenter supersymmetric black hole solutions provides a supergravity description of such backgrounds within which a black hole can be trapped within a confined volume. This construction is realized by solving for a levitating black hole over a magnetic dipole base. We comment on how such a construction is akin to a mechanical levitron.

  12. Studies on the frictional behavior of magnetic recording tapes

    Science.gov (United States)

    Kalfayan, S. H.; Silver, R. H.; Hoffman, J. K.

    1972-01-01

    Methods were developed for measuring frictional forces acting on a magnetic tape in motion or at rest, as well as the extent of stick slip. The effects of factors such as temperature, humidity, kind of gaseous atmosphere, and tape speed on the frictional interaction between various tapes and heads were investigated. Results were instrumental in the selection of a tape for the Mariner Mars 1971 spacecraft. Studies are reported on the stick slip behavior of tapes and the performance of a metallic tape, compared with the usual plastic tapes.

  13. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  14. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  15. Near-horizon Structure of Escape Zones of Electrically Charged Particles around Weakly Magnetized Rotating Black Hole

    Science.gov (United States)

    Kopáček, Ondřej; Karas, Vladimír

    2018-01-01

    An interplay of magnetic fields and gravitation drives accretion and outflows near black holes. However, a specific mechanism is still a matter of debate; it is very likely that different processes dominate under various conditions. In particular, for the acceleration of particles and their collimation in jets, an ordered component of the magnetic field seems to be essential. Here we discuss the role of large-scale magnetic fields in transporting the charged particles and dust grains from the bound orbits in the equatorial plane of a rotating (Kerr) black hole and the resulting acceleration along trajectories escaping the system in a direction parallel to the symmetry axis (perpendicular to the accretion disk). We consider a specific scenario of destabilization of circular geodesics of initially neutral matter by charging (e.g., due to photoionization). Some particles may be set on escaping trajectories and attain relativistic velocity. The case of charged particles differs from charged dust grains by their charge-to-mass ratio, but the acceleration mechanism operates in a similar manner. It appears that the chaotic dynamics controls the outflow and supports the formation of near-horizon escape zones. We employ the technique of recurrence plots to characterize the onset of chaos in the outflowing medium. We investigate the system numerically and construct the basin-boundary plots, which show the location and the extent of the escape zones. The effects of black hole spin and magnetic field strength on the formation and location of escape zones are discussed, and the maximal escape velocity is computed.

  16. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    Science.gov (United States)

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  17. Phase structure, rheology and electrical conductivity of co-continuous polystyrene/polymethylmethacrylate blends filled with carbon black

    Czech Academy of Sciences Publication Activity Database

    Scherzer, S. L.; Pavlova, Ewa; Esper, J. D.; Starý, Z.

    2015-01-01

    Roč. 119, 23 November (2015), s. 138-147 ISSN 0266-3538 R&D Projects: GA TA ČR(CZ) TE01020118 Institutional support: RVO:61389013 Keywords : polymer-matrix composites * electrical properties * rheology Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.897, year: 2015

  18. Optically activated magnetic recording tape

    Science.gov (United States)

    Marks, A. M.; Shulman, A. R.

    1970-01-01

    Optically activated data storage medium visually and electromagnetically reproduces a recorded signal. In an electric field, particles in heat-fluidized thermoplastic layer form a visible image of the recorded signal. Refluidizing the thermoplastic layer erases the signals. Very high data packing densities are achieved.

  19. Black hole levitron

    NARCIS (Netherlands)

    Arsiwalla, X.D.; Verlinde, E.P.

    2010-01-01

    We study the problem of spatially stabilizing four dimensional extremal black holes in background electric/magnetic fields. Whilst looking for stationary stable solutions describing black holes placed in external fields we find that taking a continuum limit of Denef et al.’s multicenter

  20. Kinesio Taping technique and Kinesio Tex

    Directory of Open Access Journals (Sweden)

    Dan Brăteanu

    2009-12-01

    Full Text Available Kinesio Taping is a method of application of a special tape, adhesive and elastic, which imitates the qualities of the skin.Taping tape is named Kinesio Tex, is made of cotton with acrylic adhesive and it applies directly on skin, on affected musclelength and/or around some joints depending on affection, having the quality of not modifing the biomechanical movement andto facilitate the blood and limphatic circulation of the respective area. It is easy supported on skin/by skin, reduces the painand swelling, lets the skin to breathe, can be worn 3 to 5 days continuously, and a roll can be used for 6 to 10 applications.The method can be used for the majority of affections of the locomotion system and not only; can be used by anyone at anyage. Development of the technique started at the Olympic Games in Seul, 1988, beeing used by athlets. At this moment thetape is recomended and used frequently by the doctors and athlets from Japan, USA, Europe, South America, Australia andother asian countries. Kinesio Taping technique should be applied under the advice of a practician, the efficient results aregoing to be obtained only by corectly appliance in different situations.

  1. Ubiquitous Graphene Electronics on Scotch Tape

    Science.gov (United States)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  2. Black to Black

    DEFF Research Database (Denmark)

    Langkjær, Michael Alexander

    2012-01-01

    Pop musicians performing in black stage costume take advantage of cultural traditions relating to matters black. Stylistically, black is a paradoxical color: although a symbol of melancholy, pessimism, and renunciation, black also expresses minimalist modernity and signifies exclusivity (as is hi...... suggested that appreciation of the highly personal motives of both Siouxsie Sioux and Janelle Monáe in wearing black may be achieved via analogies with the minimalist sublime of American artists Frank Stella’s and Ad Reinhardt’s black canvasses.......Pop musicians performing in black stage costume take advantage of cultural traditions relating to matters black. Stylistically, black is a paradoxical color: although a symbol of melancholy, pessimism, and renunciation, black also expresses minimalist modernity and signifies exclusivity (as...... is hinted by Rudyard Kipling’s illustration of ‘The [Black] Cat That Walked by Himself’ in his classic children’s tale). It was well understood by uniformed Anarchists, Fascists and the SS that there is an assertive presence connected with the black-clad figure. The paradox of black’s abstract elegance...

  3. Microforming process for embossing of LTCC tapes

    Science.gov (United States)

    Bartsch, H.; Albrecht, A.; Hoffmann, M.; Müller, J.

    2012-01-01

    Embossing of low-temperature cofired ceramics (LTCC) enables the fine patterning of these multilayer materials in the green state and thus allows the fabrication of smart ceramic microsystems even for moderate quantities or prototypes. To understand the embossing process, mechanical properties such as the viscoelastic modulus, yield strain and densification are investigated for commercially available LTCC tapes. The forming and shrinkage behaviour are compared for large cavities as well as for fine patterns. The results are discussed and a comprehensive explanation of the forming mechanism is worked out. Relevant material properties are identified and the microforming of different tapes is explained under consideration of their mechanical properties. This paper therefore gives an essential guide to understanding the main forming influences and failures for LTCC tapes.

  4. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  5. CLEARANCE OF ARCHIVE TAPE VAULT (BUILDING 186)

    CERN Multimedia

    EP Division

    1999-01-01

    The archive tape vault is being cleared to make way for the LHC experiments silicon facility.Experiments were contacted in February to arrange for the extended storage or destruction of archived volumes. Any who have not yet done so are asked to contactR. Minchin/IT immediately.This is also an opportunity to clear unused tapes or cartridges from around the site and have them destroyed ecologically. Please contact ep.smi.helpdesk@cern.ch to arrange for collection.A.E. Ball/EP-SMI

  6. Localized leak detection using moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    In the United States the concept of localized leak detection has become an accepted monitoring method for existing conditions such as intergranular stress corrosion cracking and for conditions which may be present in pipes which are inaccessible to currently used monitoring systems. Among the options which exist for augmented localized leak detection systems are moisture sensitive tape and acoustic emission. Choice of system depends upon the number of locations to be monitored, the environment, total installed cost and operating cost. The Techmark multiplex moisture sensitive tape system is described. (U.K.)

  7. The NT digital micro tape recorder

    Science.gov (United States)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    1993-01-01

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  8. Relationship between trapezius muscle activity and typing speed: taping effect.

    Science.gov (United States)

    Huang, Tsun-Shun; Cheng, Wei-Cheng; Lin, Jiu-Jenq

    2012-01-01

    Clinically, over-activation of upper trapezius (UT) muscular activity is a common cause of symptoms in computer users. The purpose of this study was to investigate the correlation between trapezius muscular activity and typing speed with and without taping. Twelve participants performed a typing task for 15 min with and without taping on the UT muscle. Electromyography (EMG) of the muscular activity of UT and lower trapezius (LT) was recorded. With or without taping, there was a significantly positive correlation (r = 0.40, p = 0.04) between typing speed and UT/LT. Additionally, UT and UT/LT ratios were lower with taping than without taping (difference = 5.2% and 26.9%). The LT ratio was higher with taping than without taping (difference = 5.8%). Taping can alter the muscular activity of the trapezius during typing and may have the potential to be applied in computer users to prevent over-activation of UT muscular activity. Practitioner Summary: The effect of taping was tested on typing speed and trapezius muscular activity. With or without taping, typing speed was correlated with trapezius activity. The muscle activity of the trapezius, however, was lower with taping than without taping. Thus, taping has the potential to prevent over-activation of UT muscular activity during typing.

  9. Carbon black as an alternative cathode material for electrical energy recovery and transfer in a microbial battery.

    Science.gov (United States)

    Zhang, Xueqin; Guo, Kun; Shen, Dongsheng; Feng, Huajun; Wang, Meizhen; Zhou, Yuyang; Jia, Yufeng; Liang, Yuxiang; Zhou, Mengjiao

    2017-08-01

    Rather than the conventional concept of viewing conductive carbon black (CB) to be chemically inert in microbial electrochemical cells (MECs), here we confirmed the redox activity of CB for its feasibility as an electron sink in the microbial battery (MB). Acting as the cathode of a MB, the solid-state CB electrode showed the highest electron capacity equivalent of 18.58 ± 0.46 C/g for the unsintered one and the lowest capacity of 2.29 ± 0.48 C/g for the one sintered under 100% N 2 atmosphere. The capacity vibrations of CBs were strongly in coincidence with the abundances of C=O moiety caused by different pretreatments and it implied one plausible mechanism based on CB's surface functionality for its electron capturing. Once subjected to electron saturation, CB could be completely regenerated by different strategies in terms of electrochemical discharging or donating electrons to biologically-catalyzed nitrate reduction. Surface characterization also revealed that CB's regeneration fully depended on the reversible shift of C=O moiety, further confirming the functionality-based mechanism for CB's feasibility as the role of MB's cathode. Moreover, resilience tests demonstrated that CB cathode was robust for the multi-cycles charging-discharging operations. These results imply that CB is a promising alternative material for the solid-state cathode in MBs.

  10. Thermally Conductive Tape Based on Carbon Nanotube Arrays

    Science.gov (United States)

    Kashani, Ali

    2011-01-01

    To increase contact conductance between two mating surfaces, a conductive tape has been developed by growing dense arrays of carbon nanotubes (CNTs, graphite layers folded into cylinders) on both sides of a thermally conductive metallic foil. When the two mating surfaces are brought into contact with the conductive tape in between, the CNT arrays will adhere to the mating surface. The van der Waals force between the contacting tubes and the mating surface provides adhesion between the two mating surfaces. Even though the thermal contact conductance of a single tube-to-tube contact is small, the tremendous amount of CNTs on the surface leads to a very large overall contact conductance. Interface contact thermal resistance rises from the microroughness and the macroscopic non-planar quality of mating surfaces. When two surfaces come into contact with each other, the actual contact area may be much less than the total area of the surfaces. The real area of contact depends on the load, the surface roughness, and the elastic and inelastic properties of the surface. This issue is even more important at cryogenic temperatures, where materials become hard and brittle and vacuum is used, which prevents any gas conduction through the interstitial region. A typical approach to increase thermal contact conductance is to use thermally conducting epoxies or greases, which are not always compatible with vacuum conditions. In addition, the thermal conductivities of these compounds are often relatively low. The CNTs used in this approach can be metallic or semiconducting, depending on the folding angle and diameter. The electrical resistivity of multiwalled carbon nanotubes (MWCNTs) has been reported. MWCNTs can pass a current density and remain stable at high temperatures in air. The thermal conductivity of a MWCNT at room temperature is measured to be approximately 3,000 W/m-K, which is much larger than that of diamond. At room temperature, the thermal conductance of a 0.3 sq cm

  11. PCM magnetic tape system efficiently records and reproduces data

    Science.gov (United States)

    Cole, P. T.

    1965-01-01

    Split-phase PCM technique consists of data and clock signal recording and reproduction systems. This PCM magnetic tape system achieves a high packing density on the tape and provides a symmetrical reproduction of the recorded signal.

  12. Tape Recorded American History: Effects on Reading and Listening

    Science.gov (United States)

    Hasselrils, Peter

    1968-01-01

    Measures the effects of tape recordings alone, tape recordings and printed texts, and printed texts alone on the comprehension, oral reading, and vocabulary abilities of eighth-grade students and reports no significant differences with any method. Bibliography. (MD)

  13. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  14. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  15. Teaching with tape-recorded psychoanalysis.

    Science.gov (United States)

    Firestein, S K

    2001-07-01

    The pedagogic advantages of the study of psychoanalytic process with the help of tape-recorded psychoanalytic sessions is described, with some reference to others' experiences with recording drawn from the literature. Illustration is provided through reference to the reactions of fourth- and fifth-year psychoanalytic candidates to such samplings of one patient's recorded analysis.

  16. Melt processing of Yb-123 tapes

    International Nuclear Information System (INIS)

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-01-01

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J c increased with decrease in pO 2 . The highest I c obtained was 52 A at 4.2 K

  17. Carbon Nanotube-Based Synthetic Gecko Tapes

    Science.gov (United States)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  18. Effect of kinesio-taping on ankle joint stability

    Directory of Open Access Journals (Sweden)

    Mervat A. Mohamed

    2016-05-01

    Full Text Available Ankle Instability is characterized by recurrent giving way and often develops after repeated lateral ankle sprains. Kinesiotape is more elastic than traditional athletic tape and is becoming increasingly popular. It is reported to decrease pain, improve muscle function, circulation and proprioception, however, research examining the effects of Kinesiotape in ankle instability is limited. The objective of this study was to determine if applying Kinesiotape to unstable ankle may improve performance in the Star Excursion Balance Test (SEBT, which has been shown to be a sensitive and reliable measure for quantifying dynamic balance. Thirty subjects with first degree ankle sprain were participated in this study. SEBT was used to test the subject dynamic balance under three conditions; without taping, with white athletic tape and with kinesiotape. One way repeated measure ANOVA using Greenhouse-Geisser corrections were conducted to evaluate differences in SEBT for the three conditions. Pairwise comparison of the outcome measures in the three occasions (without taping, with athletic taping, and with kinesio taping revealed statistically significant differences of all outcomes between occasion 1 (without taping and occasion 2 (with athletic taping favoring the athletic taping (p < 0.05. Also, a statistically significant difference between occasion 1 (without taping and occasion 3 (with kinesio taping were found (p < 0.05 favoring kinesio taping. Moreover, pairwise comparison of the ankle stability outcomes using athletic taping versus kinesio taping indicated a statistically significant difference (p < 0.05 in favor of kinesio taping measures. Conclusion: kinesiotape has superior effect than athletic tape in patients with first degree ankle sprain and can be used safely for improving ankle joint stability.

  19. Books on Tape: Speaking Softly and Carrying a Big Backlist.

    Science.gov (United States)

    Annichiarico, Mark

    1994-01-01

    Describes Books on Tape, an unabridged audiobook publisher, and its appeal to the library market. Discussion covers reading styles used on the tapes, the lack of celebrity readers, the story of the company's founding and development, its use of computerized customer tracking and networking, the availability of replacement tapes, and cassette cover…

  20. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Science.gov (United States)

    2010-04-01

    ... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record and... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  1. AC susceptibility as a characterization tool for coated conductor tapes

    Science.gov (United States)

    Gömöry, F.; Vojenčiak, M.; Solovyov, M.; Frolek, L.; Šouc, J.; Seiler, E.; Bauer, M.; Falter, M.

    2017-11-01

    The measurement and analysis of magnetic AC susceptibility is a useful tool in the study of superconductor (SC) materials. Exposure of a sample to a magnetic field changing in time generates loops of electrical currents that are detectable in a contactless way with the help of a suitable pick-up system. In this paper the applicability of this technique in the characterization and quality control of coated conductor (CC) tapes is evaluated. First we recollect the essential results of the analytical theory derived for thin SC strips and their extrapolation to strips with finite thickness. From the analytical expressions one can see how the properties of CC tape that are important for application in electric power devices, namely its critical current and AC loss, can be deduced from AC susceptibility data in straightforward way. The main focus of our study is to investigate the influence that various cases of non-uniformities in SC layer exhibit on the magnetic properties examined in an AC regime. Numerical computations were used to explore the consequences of lateral variation in the critical current density. Predictions derived for some model cases were compared with experimental findings. A dedicated experiment was also carried out to demonstrate that a transverse scratch that would be detrimental for DC transport could sneak unobserved through the AC magnetic experiment on a long sample. Our study shows that the analysis of both parts of the complex magnetic susceptibility in place of a mere AC loss determination in a common AC magnetization experiment is worth the additional effort.

  2. Obituary: Gerald Frederick Tape, 1915-2005

    Science.gov (United States)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  3. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  4. Effects of kinesio taping on anaerobic power and capacity results.

    Science.gov (United States)

    Harmanci, Halit; Kalkavan, Arslan; Karavelioglu, Mihri B; Yuksel, Oğuzhan; Şentürk, Aydin; Gülaç, Meryem; Altinok, Betül

    2016-06-01

    Kinesio taping is a therapeutic method used by physiotherapists during musculoskeletal and neuromuscular disorders. Efficacy of the kinesio taping implementation on sport performance is inconsistent. The purpose of this study was to determine the effects of kinesio taping on 30 second-repeated jump power, wingate anaerobic power and wingate anaerobic capacity results. Thirty one healthy male athletes volunteered to participate in this study. The subjects were randomly assigned to one of two groups: a kinesio taping group (16 subjects; X age: 21.87±2.02 years) and a without kinesio taping group (15 subjects; X age: 21.66±1.67 years). The Kinesio taping group was taped with a Y-shaped kinesio tape at the quadriceps muscles according to the Kenzo Kase's Kinesio taping manual. A dependent t-test was used to compare the anaerobic power and capacity measurements before and after the kinesio taping application. No significant differences were found for absolute wingate anaerobic power, relative wingate anaerobic power, absolute wingate anaerobic capacity, relative wingate anaerobic capacity and 30 second-repeated jump power outputs after the kinesio taping application (P>0.05).

  5. Optimizing ankle performance when taped: Effects of kinesiology and athletic taping on proprioception in full weight-bearing stance.

    Science.gov (United States)

    Long, Zhi; Wang, Renwei; Han, Jia; Waddington, Gordon; Adams, Roger; Anson, Judith

    2017-03-01

    To explore the effects of kinesiology taping (KT) and athletic taping (AT) on ankle proprioception when tested in functional, full weight-bearing stance. Cross-sectional study. Twenty-four healthy university students participated. Proprioception was measured using the Active Movement Extent Discrimination Apparatus (AMEDA). The three testing conditions: no-taping, KT, AT, and foot tested were randomly assigned. Perceived comfort, support and proprioceptive performance under two taping conditions were recorded. Proprioceptive discrimination scores with 95% CIs for no-taping, KT and AT were 0.81 (0.79-0.84), 0.81 (0.79-0.83), and 0.79 (0.77-0.81). Repeated measures ANOVA showed neither any significant difference associated with taping compared with no-taping (p=0.30), nor any difference between KT and AT (p=0.19). The group was then divided, according to their no-taping scores, into two sub-groups: with scores below the no-taping mean (n=13), and above the mean (n=11). ANOVA revealed a significant interaction (p=0.008) indicating that above-average no-taping performers proprioception scores were worse when taped, whereas below-average performers improved. For both KT and AT, only ratings of perceived comfort when taped were significantly associated with actual proprioceptive performance (both r>0.44, p≤0.03). Other perception ratings (support and performance) were significantly inter-correlated (both r>0.42, p0.31). Taping of the foot and ankle may amplify sensory input in a way that enhances proprioception of poor performers but produces an input overload that impairs proprioception in those who originally performed well when no-taping. Screening of ankle proprioception may identify those who would benefit most from taping. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Development of thermoplastic-photoconductor tape for optical recording.

    Science.gov (United States)

    Lee, T C; Marzwell, N I; Schmit, F M; Tufte, O N

    1978-09-01

    We report in this paper the continuous coating of the thermoplastic-photoconductor medium on a transparent polyester tape base for holographic optical data recording. The tape performance is evaluated in a moving transport at speeds up to 15 ips (38.1 cm/sec). Uniform diffraction efficiencies for both 2-D and 1-D holograms have been demonstrated. Furthermore, we have recorded complex 1-D holograms on the moving tape with high quality readout, and we have also made complex spatial filters on the tape which produce good correlation results in a coherent optical data processor. Numerous material factors affecting the performance of the tape in a moving tape system have been defined and investigated. Factors such as coating uniformity, electrode reflectivity, photoconductor reciprocity, the pressure endurance of the surface relief, and the tape noise are singled out for discussion in this paper.

  7. Transport current loss of BSCCO/Ag tape in different orientations of the external alteranting magnetic field

    NARCIS (Netherlands)

    Rabbers, J.J.; ten Haken, Bernard; ten Kate, Herman H.J.

    1999-01-01

    BSCCO/Ag tapes are being developed for electrical power applications at liquid nitrogen temperatures. In these applications, conductors are exposed to an alternating magnetic field and fed simultaneously with an alternating transport current. In this contribution the influence of an external

  8. Investigation and comparison of AC losses on stabilizer-free and copper stabilizer HTS tapes

    Science.gov (United States)

    Shen, Boyang; Li, Jing; Geng, Jianzhao; Fu, Lin; Zhang, Xiuchang; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Coombs, T. A.

    2017-10-01

    This paper presents the measurement and simulation of Alternating Current (AC) losses on the Stabilizer-free and Copper Stabilizer High Temperature Superconducting (HTS) Tapes: SuperPower SF12100 and SCS12050. The AC loss measurement utilised electrical method to obtain overall losses with AC transport currents. The 2D H-formulation by COMSOL Multiphysics has been used to simulate the real geometry and multi-layer HTS tapes. Ferromagnetic AC losses of substrate have been assumed to be ignored as the substrates of SF12100 and SCS12050 are non-magnetic. Hysteresis AC losses in the superconducting layer, and eddy-current AC losses in copper stabilizer, silver overlayer and substrate were concerned in this investigation. The measured AC losses were compared to the AC losses from simulation, with 3 cases of different AC frequency 10, 100, and 1000 Hz. The eddy-current AC losses of copper stabilizer at frequency 1000 Hz were determined from both experiment and simulation. The estimation of AC losses with frequency at 10,000 Hz was also carried out using simulation method. Finally, the frequency dependence of AC losses from Stabilizer-free Tape and Copper Stabilizer Tape were compared and analysed.

  9. The four silo STK Powderhorn Tape Library

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    A view of the four silo Storage Tek (STK) Powderhorn Tape Library and its control area. Each silo can contain up to 6000 storage slots with cartridges of 10, 20, 25 or 50 GB capacity, reaching a data transfer rate of up to 12 Mbytes/sec. This will form part of the Grid system that will process the huge amounts of data produced at the LHC.

  10. Use of video taping during simulator training

    International Nuclear Information System (INIS)

    Helton, M.; Young, P.

    1987-01-01

    The use of a video camera for training is not a new idea and is used throughout the country for training in such areas as computers, car repair, music and even in such non-technical areas as fishing. Reviewing a taped simulator training session will aid the student in his job performance regardless of the position he holds in his organization. If the student is to be examined on simulator performance, video will aid in this training in many different ways

  11. Pressure Roller For Tape-Lift Tests

    Science.gov (United States)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  12. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p < 0.05) and after detaching the tape (p < 0.01) compared to the first measurement. Our results indicate that the perception of the area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Enhancing the low-level tape layer of CERN Tape Archive software

    CERN Document Server

    AUTHOR|(CDS)2160814; Ruse, Laura Cristina; Vasilescu, Laura

    CERN manages the largest scientific data archive in the HEP domain. The archive currently holds over 180 Petabytes, with forecasts of up to 100PB of new data added per year. Considering this numbers, the most cost-effective solution for storage in terms of capacity and maintenance is represented by magnetic tapes. The drawback of this solution is the access time which can raise to several minutes for a series of files. In an environment where very large volumes of physics data are being traded from tape to disk and vice versa, this issue becomes a serious performance bottleneck. This thesis introduces two low-level tape access optimizations: first, adding support for the Recommended Access Order (RAO), a mechanism offered by the tape hardware infrastructure to compute the file order corresponding to the minimum access time. We will present our solution for including RAO in the file retrieval operations in CERN tape archive software in order to benefit from the reduced reading time. The second optimization ...

  14. Insulating and sheathing materials of electric and optical cables: common test methods part 4-1: methods specific to polyethylene and polypropylene compounds – resistance to environmental stress cracking – measurement of the melt flow index – carbon black and/or mineral filler content measurement in polyethylene by direct combustion – measurement of carbon black content by thermogravimetric analysis (TGA) – assessment of carbon black dispersion in polyethylene using a microscope

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2004-01-01

    Specifies the test methods to be used for testing polymeric insulating and sheathing materials of electric cables for power distribution and telecommunications including cables used on ships. Gives the methods for measurements of the resistance to environmental stress cracking, for wrapping test after thermal ageing in air, for measurement of melt flow index and for measurement of carbon black and/or mineral filler content, which apply to PE and PP coumpounds, including cellular compounds and foam skin for insulation.

  15. Transobturator tapes are preferable over transvaginal tapes for the management of female stress urinary incontinence: Against

    Directory of Open Access Journals (Sweden)

    Arun Chawla

    2009-01-01

    Full Text Available Midurethral placement of tension-free vaginal tapes with a transvaginal route for stress urinary incontinence achieves higher and better long-term success rates than the transobturator route. Bladder perforations are reported more in transvaginal tape (TVT but incidences of vaginal erosions, extrusion, and groin pain are exceedingly more in TOT groups. There is no clear evidence that transobturator tape (TOT is associated with less post-operative voiding problems than TVT. Major complications such as bowel injuries and significant vascular injuries with TVT are rare. TVT has been found to be superior to TOT and preferable in technically demanding conditions such as prior anti-incontinence operation failures, obese women, and very elevated and scarred lateral cul-de sac. TVT is always preferred in severe grades of stress urinary incontinence and with patients of intrinsic sphincter deficiency (ISD with little or no urethral mobility.

  16. Severe Groin Pain Following Transobturator Tape Procedure Necessitating Partial Removal of the Tape

    Directory of Open Access Journals (Sweden)

    Gökçe Anık İlhan

    2016-01-01

    Full Text Available Groin pain after transobturator tape (TOT procedure can occur; however, severe groin pain and difficulty in ambulating requring exploration of the obturator compartment and surgical excision of the tape is uncommon. We present a case with severe groin pain after uncomplicated TOT in which the patient could not stand the pain despite conservative treatment. Unlike most cases presented in the literature, the pain could only be releived by partial removal of the tape. Although TOT is an effective and safe procedure in the treatment of stress urinary incontinance, obturator nerve entrapment may rarely occur and mesh dissection and excision may be the only choice to releive the pain in these patients with untolerable severe symptoms.

  17. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    Science.gov (United States)

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  18. Black holes

    International Nuclear Information System (INIS)

    Feast, M.W.

    1981-01-01

    This article deals with two questions, namely whether it is possible for black holes to exist, and if the answer is yes, whether we have found any yet. In deciding whether black holes can exist or not the central role in the shaping of our universe played by the forse of gravity is discussed, and in deciding whether we are likely to find black holes in the universe the author looks at the way stars evolve, as well as white dwarfs and neutron stars. He also discusses the problem how to detect a black hole, possible black holes, a southern black hole, massive black holes, as well as why black holes are studied

  19. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wen-Dien Chang

    2015-01-01

    Full Text Available Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS. Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life.

  20. Texture of YBCO/Ag PIT-tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Kulmala, T.; Raittila, J.

    2004-01-01

    with X-ray diffraction. A clear correlation between 1, and c-axis texture is found and even some evidence of ab-texturing in the very best tapes. Less texture is found when the middle of the filament is exposed by cutting the tape. This suggests that multifilament tapes with smaller filament cross......YBCO/Ag tapes prepared using nanosized YBCO powder are currently the best powder-in-tube YBCO tapes with their I-c = 5.02 A and J(c) = 3300 A/cm(2) in self-field and at 77 K. The texture of these tapes was studied by removing the silver with mercury and then measuring the texture of the surface...

  1. Cognitive screening using a tape recorder: a pilot study.

    Science.gov (United States)

    Schofield, Peter W; Lee, Stephen J; Davies, Graeme C

    2003-03-01

    To determine whether a tape recorder can be used to administer cognitive tests efficiently and yield valid results. Convenience sample. Administration of cognitive test materials by tape recorder and conventional technique. Outpatient clinic. Subjects from memory disorder clinic, hostel accommodation, and community. Responses to Hopkins Verbal Learning Test-revised, verbal fluency items from the controlled oral word association test, 10-item naming task, a construction task, and speed writing task. Performances on the tape- and clinician-administered battery of tests were highly correlated. Memory impairment was accurately detected using the tape battery. Data from 30 minutes of testing via tape were obtained at the cost to the clinician of 2 to 3 minutes of scoring time. Tape-administration of cognitive test material warrants further study as an efficient means of cognitive screening.

  2. Applicability of DNA analysis on adhesive tape in forensic casework.

    Science.gov (United States)

    Zech, Wolf-Dieter; Malik, Naseem; Thali, Michael

    2012-07-01

    Adhesive tape is commonly used in crimes and is often the subject of forensic evaluation. DNA analysis of adhesive tape can provide DNA profiles of suspects. The object of this study was to evaluate the applicability of DNA analysis on adhesive tape samples in forensic casework. We retrospectively reviewed all cases involving adhesive tape or similar items received by our institute for DNA analysis during the past 11 years. From 100 forensic cases reviewed, 150 adhesive tape samples were examined. A total of 98 DNA profiles were obtained from these samples. Sixty-two of the profiles provided feasible case-relevant information. In conclusion, DNA profiling of adhesive tape samples can be useful in a variety of forensic cases. © 2012 American Academy of Forensic Sciences.

  3. Identification of pressure-sensitive adhesive polypropylene tape.

    Science.gov (United States)

    Sakayanagi, Masataka; Konda, Yaeko; Watanabe, Kunio; Harigaya, Yoshihiro

    2003-01-01

    Identification of colorless, transparent, pressure-sensitive adhesive polypropylene tape (PP tape) was performed using infrared absorption spectrometry (IR) and pyrolysis gas chromatography mass spectrometry (Py-GC/MS) to determine the pressure-sensitive adhesive. Twenty different products of colorless, transparent PP tapes were examined in this study, and the results of analysis of IR spectra and Py-GC/MS were classified into twelve groups. In addition, the tapes were classified into 14 groups on the basis of IR measurement of release agent present in the backside. The results indicate that colorless, transparent PP tapes can be distinguished in terms of manufacturer, thereby demonstrating that this method of identifying colorless, transparent PP tape is effective. Moreover, the method was applied to the analysis of an actual forensic sample.

  4. Influence of gamma ray irradiation on thermal conductivity of bismaleimide-triazine-based insulation tape at cryogenic temperature

    Science.gov (United States)

    Yang, Y.; Yoshida, M.; Idesaki, A.; Ogitsu, T.

    2018-01-01

    Recent accelerator-based experiments for particle physics require the superconducting magnets that can be operated under high radiation environment. An electrical insulation tape, which is composed of polyimide film and a boron free glass fabric pre-impregnated with epoxy resin blended with bismaleimide-triazine resin, is developed to enhance the radiation tolerance for superconducting magnets. Since the thermal conductivity of insulation tape is one of key parameters that affects the coil temperature during the operation, the influence of gamma-ray irradiation on the thermal conductivity of the insulation tape is investigated with a maximum dose of 5 MGy. The thermal conductivity is measured at cryogenic temperature from 5 K to 20 K cooled by a Gifford-McMahon cryocooler. By comparing the thermal conductivity before and after the gamma ray irradiation, no significant degradation on the thermal conductivity has been observed.

  5. GSFC specification electronic data processing magnetic recording tape

    Science.gov (United States)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  6. Kinetics of the humid aging of magnetic recording tape

    Science.gov (United States)

    Bertram, H. N.; Cuddihy, E. F.

    1982-01-01

    The kinetics of the hydrolysis of polyester urethane binders of magnetic recording tape is described. Kinetic data were generated from measurements of acetone-extractable hydrolyzed binder products versus time for various humidity-temperature environments. These data can be described by a linear, single product, reversible rate equation. This equation, coupled with measurements on the effect of hydrolysis on recorded tape performance, is used to predict proper environmental storage conditions for magnetic tape.

  7. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  8. Characterization of Tape Adhesion to Chemical Agent Resistant Coatings

    Science.gov (United States)

    2015-01-01

    Performance criterion for tape adhesion has been set by the CARC Commodity Manager at 80 inch ounce-force using IAW ASTM D 3330, Peel Adhesion of Pressure ...D3330M-04(2010). “Standard Test Method for Peel Adhesion of Pressure -Sensitive Tape ”. Aunnu. Book ASTM Stand. 2010. 14 Wave Matrix. Computer...ARL-RP-0517 ● JAN 2015 US Army Research Laboratory Characterization of Tape Adhesion to Chemical Agent Resistant Coatings by

  9. Information retrieval system based on INIS tapes

    International Nuclear Information System (INIS)

    Pultorak, G.

    1976-01-01

    An information retrieval system based on the INIS computer tapes is described. It includes the three main elements of a computerized information system: a data base on a machine -readable medium, a collection of queries which represent the information needs from the data - base, and a set of programs by which the actual retrieval is done, according to the user's queries. The system is built for the center's computer, a CDC 3600, and its special features characterize, to a certain degree, the structure of the programs. (author)

  10. StorageTek T10000 Tape Cartridge

    CERN Multimedia

    1985-01-01

    Oracle StorageTek T10000T2 cartridge has total capacity of 5 TB. It is actually manufactured by Fuji Film, uses Barium Ferrite (BaFe) particles technology data store, but is also equipped with RFID chip. There is over 1 km of tape inside of the cartridge with 3584 data tracks and it supports over 25000 load/unload cycles. The archival life is estimated to be around 30 years and uncorrected bit error rate is 10-19. CERN however usually migrates data to newer technologies roughly every 5 years in order to keep the footprint under control.

  11. Lessons learned in high frequency data transmission design: ATLAS strips bus tape

    Science.gov (United States)

    Dopke, J.; Fadeyev, V.; Grillo, A. A.; Lin, B.; Martinez-Mckinney, F.; Nielsen, J.; Phillips, P.; Sawyer, C.; Sullivan, S.; Volk, J.; Wastie, R.; Weidberg, T.

    2017-01-01

    Requirements of HEP experiments lead to highly integrated systems with many electrical, mechanical and thermal constraints. A complex performance optimisation is therefore required. High-speed data transmission lines are designed using copper-polyimide flexible bus tapes rather than cable harnesses to minimise radiation length. Methods to improve the signal integrity of point-to-point links and multi-drop configurations in an ultra-low-mass system are described. FEA calculations are an essential guide to the optimisation of a tape design which supports data rates of 640 Mbps for point-to-point links over a length of up to 1.4 m, as well as 160 Mbps for multi-drop configuration. The designs were validated using laboratory measurements of S-parameters and direct bit error ratio tests.

  12. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  13. Tape-cast sensors and method of making

    Science.gov (United States)

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  14. Bi-2212/Ag tapes and laminates: effects of bending

    International Nuclear Information System (INIS)

    Ilyushechkin, A.Y.; Yamashita, T.; Williams, B.; Mackinnon, I.D.R.

    1999-01-01

    Superconducting Bi-2212 tapes and laminates are fabricated by a combination of dip-coating and partial melt processing. The heat treated tapes have critical current densities (J c ) up to 11 kA cm -2 . We investigate the degradation of critical current (I c ) during bending experiments for both single tapes and tapes with laminate structure. Although degradation of I c is observed in both forms, the characteristics of the degradation differ. It is determined that laminated tapes perform better than single tapes when critical current is measured against bending radius, and laminated tapes tolerate a higher strain for a given reduction in critical current. It is found that increasing the number of Bi-2212 layers increases the total I c of the laminated tape, but degradation of critical current is more pronounced during bending because of the increased total thickness of the laminate structure. It is also found that addition of silver to the Bi-2212 layers reduces critical current degradation during bending for both tapes and laminates. (author)

  15. Black Alcoholism.

    Science.gov (United States)

    Watts, Thomas D.; Wright, Roosevelt

    1988-01-01

    Examines some aspects of the problem of alcoholism among Blacks, asserting that Black alcoholism can best be considered in an ecological, environmental, sociocultural, and public health context. Notes need for further research on alcoholism among Blacks and for action to reduce the problem of Black alcoholism. (NB)

  16. Black Culture

    Science.gov (United States)

    Brown, Angela Khristin

    2013-01-01

    The migration of blacks in North America through slavery became united. The population of blacks passed down a tradition of artist through art to native born citizens. The art tradition involved telling stories to each generation in black families. The black culture elevated by tradition created hope to determine their personal freedom to escape…

  17. Perspectives for the electricity surplus generation at the paper and cellulose segment through the gasification of black liquor; Perspectivas para a geracao de excedentes de eletricidade no segmento de papel e celulose atraves da gaseificacao de lixivia

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez, Silvia Maria Stortini Gonzalez [Universidade Presbiteriana Mackenzie, Sao Paulo, SP (Brazil). Escola de Engenharia]. E-mail: velazquez@mackenzie.com.br; Coelho, Suani Teixeira [CENBIO - Centro Nacional de Referencia em Biomassa, Sao Paulo, Sp (Brazil)]. E-mail: suani@iee.usp.br

    2006-07-01

    The pulp/paper segment is enclosed enters the most energointensive of the industrial sector. Its industries generate great part of the energy that consume from by-products of the process, but still are not self-sufficient. On the other hand, the difficulties of the industrial sector to the availability energy guarantee are well known, due to lack of trustworthiness of the electricity transmission and distribution. In this context, the increase of the self generation of electricity in the segment's plants certainly would go to collaborate for bigger flexibility in the Brazilian energy matrix, not only for the option of Demand Side Management, but even for the possibility of electricity excesses generation, as it is considered in this study. Thus, this work presents an economic and technique analysis of the energy cogeneration and the generation of electricity excesses in the pulp and paper segment and cellulose using more efficient technologies (although in development), as the black liquor gasification. The perspectives for the use of black liquor gasification systems and coupling of this unit to a gas turbine (BLGCC) are studied, with exploitation of the exhaustion gases in cogeneration systems. One is about technology in development phase in the industrialized countries and that it allows high conversion efficiency. They are, also, calculated the excesses generation costs, by means of the thermo economy, on the basis of the exergy concept, the most adjusted methodology to analyze cogeneration processes. Despite the biggest efficiency, the exceeding electricity, in some of the studied configurations, presented generation costs that do not reveal competitive with the sale's price of electricity, defined for the PROINFA, leaving evident the necessity of other mechanisms that make possible the implementation of new technologies, as the incorporation of the external factors and the carbon credits discouragement of the generation costs. In the pulp and paper

  18. Black holes with halos

    Science.gov (United States)

    Monten, Ruben; Toldo, Chiara

    2018-02-01

    We present new AdS4 black hole solutions in N =2 gauged supergravity coupled to vector and hypermultiplets. We focus on a particular consistent truncation of M-theory on the homogeneous Sasaki–Einstein seven-manifold M 111, characterized by the presence of one Betti vector multiplet. We numerically construct static and spherically symmetric black holes with electric and magnetic charges, corresponding to M2 and M5 branes wrapping non-contractible cycles of the internal manifold. The novel feature characterizing these nonzero temperature configurations is the presence of a massive vector field halo. Moreover, we verify the first law of black hole mechanics and we study the thermodynamics in the canonical ensemble. We analyze the behavior of the massive vector field condensate across the small-large black hole phase transition and we interpret the process in the dual field theory.

  19. Some Uses of Tape Recordings in the Classroom.

    Science.gov (United States)

    Sell, David

    1970-01-01

    The main premise of this article is that tape recordings can be a very useful tool to the classroom language teacher. The author points out that the tapes are ideal for the habituation type of learning (dialogs, memorization, repetition, etc.,) which is preliminary to the communication stage of language learning. He is mainly concerned with five…

  20. Surreptitious Taping: The Arguments for and the Ethics against.

    Science.gov (United States)

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide…

  1. Increasing the efficiency of tape-based storage backends

    International Nuclear Information System (INIS)

    Bessone, Nicola; Cancio, German; Murray, Steve; Taurelli, Giulia

    2010-01-01

    HSM systems such as the CERN's Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for increasing the performance of repacking data from old to newer generation tape media with substantially reduced hardware costs. In this paper, we will describe the improvements for migration policies and priorities, as well as the proposed tape format and the changes which will be applied to the architecture of the CASTOR mass storage system.

  2. Critical current of various REBCO tapes under uniaxial strain

    NARCIS (Netherlands)

    Zhou, Chao; Yagotyntsev, Kostyantyn; Gao, Peng; Haugan, T.J.; van der Laan, D.C.; Nijhuis, Arend

    2016-01-01

    For high-current REBCO superconductors in high magnet fields with currents on the order of 50 kA, single coated conductors must be assembled in a cable. Under operating conditions, such cables are subjected to combined torsion, axial, and transverse loads in the tapes and tape joints. As such, the

  3. The Uses of Video Tape in Training and Development.

    Science.gov (United States)

    Stroh, Thomas Frederick

    Video tape recording systems are used in a variety of ways in training programs for commerce and industry. A questionnaire, which drew responses from about 200 companies, identified the advantages as well as the problems of video tape usage. Many of its uses in training of industrial and sales personnel involve role playing, which in itself…

  4. StorageTek RedWood SD-3 tape drive

    CERN Multimedia

    1995-01-01

    A helical scan recording drive, with a high-speed rotating head sweeping across the tape every few micrometers. Based on a professional video recording system, modified to be suitable for digital data recording. These are commonly used with large computer systems, typically in conjunction with a robotic tape library.

  5. Time complexity of tape reduction for reversible Turing machines

    DEFF Research Database (Denmark)

    Axelsen, Holger Bock

    2012-01-01

    in reversible computing theory are about multitape machines with two or more tapes, but it is non-obvious what these results imply for reversible complexity theory. Here, we study how the time complexity of multitape RTMs behaves under reductions to one and two tapes. For deterministic Turing machines...

  6. Edge effects and submicron tracks in magnetic tape recording

    NARCIS (Netherlands)

    Hozoi, A.; Hozoi, Adrian

    Edge Effects and Submicron Tracks in Magnetic Tape Recording As track widths in magnetic tape recording are approaching few micrometers, increasingly better control of the track edges is required. This thesis is concerned with the investigation of the recording process in narrow tracks down to the

  7. Tape Stripping Technique for Stratum Corneum Protein Analysis

    DEFF Research Database (Denmark)

    Clausen, Maja-Lisa; Slotved, H.-C.; Krogfelt, Karen Angeliki

    2016-01-01

    The aim of this study was to investigate the amount of protein in stratum corneum in atopic dermatitis (AD) patients and healthy controls, using tape stripping technique. Furthermore, to compare two different methods for protein assessment. Tape stripping was performed in AD patients and healthy ...

  8. Tools for applying lead tape to flat conductor cabling for chemical stripping

    Science.gov (United States)

    Angele, W.

    1969-01-01

    Two tools facilitate chemical stripping of insulation on flat conductor cabling. A tape pressing tool and a taping fixture apply adhesive lead tape with the proper amount of pressure to protect the remaining insulation from the chemical stripping solution.

  9. The Effects of Spiral Taping Treatment on Low Back Pain

    Directory of Open Access Journals (Sweden)

    Hwang Jae-Ok

    2006-02-01

    Full Text Available Objective : The purpose of this study is to estimate the effects of spiral taping treatment on low back pain. Methods : 420 low back pain patients were treated with spiral taping or spiral taping plus herbal medicine, and no other treatments such as acupuncture, herbal acupuncture, and chiropractic therapy were added. We evaluated the improvement by physical examination and pain. Results : 364 patients felt no pain or inconvenience of daily life and 43 patients showed improvement of pain or symptom after 1 month of treatment. 13 patients showed same pain with before treatment. Conclusions : These results suggest spiral taping treatments contribute to the improvement of low back pain. Further study is needed for the confirmation of this effect of spiral taping treatments on low back pain.

  10. Two devices for atmospheric electric field measurement

    International Nuclear Information System (INIS)

    Colombet, Andre; Hubert, Pierre.

    1977-02-01

    Two instruments installed at St Privat d'Allier for electric field measurement in connection with the rocket triggered lighting experiment program are described. The first one is a radioactive probe electrometer used as a warning device. The second is a field mill used for tape recording of electric field variation during the triggering events. Typical examples of such records are given [fr

  11. Self-supported carbon electrodes obtained by tape casting

    Directory of Open Access Journals (Sweden)

    Rubio-Marcos, F.

    2006-06-01

    Full Text Available This paper describes the preparation and electrochemical response of self-supported carbon electrodes prepared by tape casting. The dc electrical conductivity, σ, of the electrodes was determined by four-wire resistance measurements and a relation between the graphite/organic additives ratio and the electrical conductivity was established. The application of these self-supported carbon electrodes as working electrodes in analytical techniques was also evaluated using norepinephrine as electroactive substance in cyclic voltammetry and chronoamperometry. The results were compared with the traditional electrodes, carbon paste electrodes (CPEs, showing that the new self-supported carbon electrodes had both lower background noise and higher analytical response.

    Este artículo describe la preparación y respuesta electroquímica de electrodos de carbono autosoportados preparados mediante colado en cinta. La conductividad eléctrica en corriente continua de este nuevo tipo de electrodos de carbono se ha determinado usando el método de cuatro puntas y se ha establecido una relación ente la relación grafito/aditivos orgánicos y la conductividad eléctrica. La aplicación de estos electrodos autosoportados como electrodos de trabajo en diversas técnicas electroanalíticas también se ha evaluado, empleando norepinefrina como analito en voltametría cíclica y en cronoamperometría. Los resultados se compararon con los obtenidos empleando los electrodos de pasta de carbono tradicionales como electrodos de trabajo, viéndose que la señal de los nuevos electrodos autosoportados poseía menor ruido de fondo y mayor respuesta analítica.

  12. HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

    International Nuclear Information System (INIS)

    Kang, Myung Hun; Ku, Myung Hwan; Cha, Guee Soo; Lim, Hyoung Woo

    2015-01-01

    The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively

  13. Effects of kinesio tape compared with nonelastic sports tape and the untaped ankle during a sudden inversion perturbation in male athletes.

    Science.gov (United States)

    Briem, Kristin; Eythörsdöttir, Hrefna; Magnúsdóttir, Ragnheidur G; Pálmarsson, Rúnar; Rúnarsdöttir, Tinna; Sveinsson, Thorarinn

    2011-05-01

    Controlled laboratory study. To examine the effect of 2 adhesive tape conditions compared to a no-tape condition on muscle activity of the fibularis longus during a sudden inversion perturbation in male athletes (soccer, team handball, basketball). Ankle sprains are common in sports, and the fibularis muscles play a role in providing functional stability of the ankle. Prophylactic ankle taping with nonelastic sports tape has been used to restrict ankle inversion. Kinesio Tape, an elastic sports tape, has not been studied for that purpose. Fifty-one male premier-league athletes were tested for functional stability of both ankles with the Star Excursion Balance Test. Based on the results, those with the 15 highest and those with the 15 lowest stability scores were selected for further testing. Muscle activity of the fibularis longus was recorded with surface electromyography during a sudden inversion perturbation. Each participant was tested under 3 conditions: ankle taped with nonelastic white sports tape, ankle taped with Kinesio Tape, and no ankle taping. Differences in mean muscle activity were evaluated with a 3-way mixed-model analysis of variance (ANOVA) for the 3 conditions, across four 500-millisecond time frames, and between the 2 groups of stable versus unstable participants. Differences in peak muscle activity and in the time to peak muscle activity were evaluated with a 2-way mixed-model ANOVA. Significantly greater mean muscle activity was found when ankles were taped with nonelastic tape compared to no tape, while Kinesio Tape had no significant effect on mean or maximum muscle activity compared to the no-tape condition. Neither stability level nor taping condition had a significant effect on the amount of time from perturbation to maximum activity of the fibularis longus muscle. Nonelastic sports tape may enhance dynamic muscle support of the ankle. The efficacy of Kinesio Tape in preventing ankle sprains via the same mechanism is unlikely, as it had

  14. Simulation and analysis of tape spring for deployed space structures

    Science.gov (United States)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  15. The application of high density tape recording to image processing

    Science.gov (United States)

    Heffner, P.

    1976-01-01

    The Image Processing Facility at Goddard Space Flight Center has the requirement to move volumes of digital data (100 billion data bits per day) that exceed the capacity of conventional computer tape. This paper presents the requirements for a high-density digital tape recorder compatible with conventional computer systems. The steps leading to the formulation of these requirements are described. The use and interaction of the recorder with the various elements in the facility are treated. The formulation of the requirements resulted in the selection of a tape transport modified for digital serial-in, serial-out operation. This selection followed a competitive procurement action.

  16. An automated magnetic tape vault at CERN computer center

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    The rapidly changing data processing landscape the underlying long-term storage technology remains the tried and tested magnetic tape. This robust and mature technology is used to store the complete LHC data set, from which a fraction of the data is copied to overlying disk caches for fast and widespread access. The handling of the magnetic tape cartridges is now fully automated, as they are racked in vaults where they are moved between the storage shelves and the tape drives by robotic arms.

  17. Experimental Tape Casting of Adjacently Graded Materials for Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina

    Functional graded materials are extensively applied in many innovative technologies, e.g. solid oxide fuel cells, solar cells, membranes, piezoactuators, capacitors, and thermoelectric systems. The synergy of advantageous combinations of composites with different composition and/or microstructure...... encompass modification of the entire tape caster into a multi chamber unit, establishment of the optimal operating parameters such as casting gap, speed, and slurry level in the tape caster reservoir, and elucidation of the impact of chamber partition design on the quality of the final tape. The second...

  18. Preparing superconducting nanopowder based YBCO/Ag tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Raittila, J.; Grivel, J.C.

    2002-01-01

    YBCO nanopowder consisting of 1-3 nm thick and 40 nm wide particles has been used to make silver clad superconducting tapes. After annealing in nitrogen at 945 degreesC for 10 h a critical current of 5.02 A (3300 A/cm(2)) was attained, Annealing in mixed atmosphere of oxygen and nitrogen was also...... carried out and this procedure produced tapes with a critical current of 2.83 A (2200 A/cm(2)). These tapes show very good characteristics in magnetic fields. (C) 2002 Elsevier Science B.V. All rights reserved....

  19. Analysis of quench development in a cryocooler cooled Bi-2223 pancake coil based on the anisotropic transport E-J characteristics in a short tape sample

    NARCIS (Netherlands)

    Kiss, T.; Noda, S.; Nishimura, S.; Ohya, K.; Utsunomiya, D.; Ilyin, Y.; Okamoto, H.

    2001-01-01

    By calculating the magnetic field distribution in a stacked pancake coil with use of finite element method and by taking into account the transport properties obtained in a short tape sample, we predict the electric field vs. current density, E–J, characteristics depending on the position inside the

  20. Shuttle-Data-Tape XML Translator

    Science.gov (United States)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  1. 13 point video tape quality guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

  2. How to make sticky tapes stickier

    Science.gov (United States)

    Ponson, Laurent; Xia, Shuman; Ravichandran, Guruswami; Bhattacharya, Kaushik; California Institute of Technology Team

    2011-03-01

    Thin film adhesives have become increasingly important in various applications such as packaging and coating, and we benefit daily of their adhesion properties by using various kinds of tapes. Despite the apparent simplicity of these systems, a certain number of questions remain open. In particular, important efforts have been deployed recently to understand the effect of the complex tridimensional and highly heterogeneous structure at the interface of some adhesives, such as the one encountered in nature like the geckos toes. Although inspired by these natural adhesives, we studied a much simpler system, and however largely unexplored: a thin film with spatially varying adhesion energy and elastic properties. We will show how these heterogeneities introduced at the microscale can generate quite unexpected macroscopic behaviors, and that one can this way design stronger adhesives with new properties. Beyond their practical interests, these systems involve long range elastic interactions and heterogeneities resulting in a rich and complex physics that will be illustrated through experimental examples and their theoretical interpretation.

  3. Attachable and flexible aluminum oxide resistive non-volatile memory arrays fabricated on tape as the substrate.

    Science.gov (United States)

    Lee, Woocheol; Jang, Jingon; Song, Younggul; Cho, Kyungjune; Yoo, Daekyoung; Kim, Youngrok; Chung, Seungjun; Lee, Takhee

    2017-03-01

    We fabricated 8 × 8 arrays of non-volatile resistive memory devices on commercially available Scotch ® Magic ™ tape as a flexible substrate. The memory devices consist of double active layers of Al 2 O 3 with a structure of Au/Al 2 O 3 /Au/Al 2 O 3 /Al (50 nm/20 nm/20 nm/20 nm/50 nm) on attachable tape substrates. Because the memory devices were fabricated using only dry and low temperature processes, the tape substrate did not suffer from any physical or chemical damage during the fabrication. The fabricated memory devices were turned to the low resistance state at ∼3.5 V and turned to the high resistance state at ∼10 V with a negative differential resistance region after ∼5 V, showing typical unipolar non-volatile resistive memory behavior. The memory devices on the tape substrates exhibited reasonable electrical performances including a high ON/OFF ratio of 10 4 , endurance over 200 cycles of reading/writing processes, and retention times of over 10 4 s in both the flat and bent configurations.

  4. Optimization of precursor powders for manufacturing Bi-2223/Ag tapes

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, C H [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang (China); Yoo, J M [Materials Engineering Department, Korea Institute of Machinery and Materials, 66 Sangnam-Dong, Changwon (Korea, Republic of); Ko, J W [Materials Engineering Department, Korea Institute of Machinery and Materials, 66 Sangnam-Dong, Changwon (Korea, Republic of); Chung, H S [Department of Molecular Science and Technology, Ajou University (Korea, Republic of); Qiao, G W [Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang (China)

    2003-01-01

    The phase assemblage and particle sizes of precursor powders have been optimized in a sequence for fabricating Ag/BSCCO-2223 composite tapes. Firstly, an optimal calcination temperature was determined based on the experimental results. Then, the precursors calcined at the optimal temperature were ball-milled for different dwell times to obtain varied particle sizes. The effects of both the phase assemblages and particle sizes of the precursor powder on the phase formation, microstructure and transport J{sub c} of Bi-2223/Ag tapes have been investigated. The results show that the precursor phase assemblage has a large impact on the reaction routes, microstructure, and J{sub c} property. Meanwhile, a fine powder is beneficial for the grain growth, alignment, and J{sub c} enhancement in fully reacted tapes. The best J{sub c} was achieved in the tape made from the powder after optimizing the phase assemblage and particle size.

  5. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  6. Taping reduces pain and disability in patients with knee osteoarthritis.

    NARCIS (Netherlands)

    Ende, E. van den

    2004-01-01

    Question: Is taping of the knee effective in improving pain and disability in patients with osteoarthritis of the knee? Design Randomised controlled trial. Setting University and private practices in Melbourne, Australia. Patients: Volunteers who responded to advertisements in local newspapers.

  7. Scotch-Tape Mirror for Hard X-rays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The project is to build a grazing incidence mirror for hard X-rays (E>20 keV) using a “scotch-tape” design, in which a thin plastic tape with a...

  8. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  9. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  10. Progress Toward Demonstrating a High Performance Optical Tape Recording Technology

    Science.gov (United States)

    Oakley, W. S.

    1996-01-01

    This paper discusses the technology developments achieved during the first year of a program to develop a high performance digital optical tape recording device using a solid state, diode pumped, frequency doubled green laser source. The goal is to demonstrate, within two years, useful read/write data transfer rates to at least 100 megabytes per second and a user capacity of up to one terabyte per cartridge implemented in a system using a '3480' style mono-reel tape cartridge.

  11. Storage, Preservation, and Recovery of Magnetic Recording Tape

    Science.gov (United States)

    Cuddihy, Edward F.

    1994-01-01

    During the 1970's, a commercial magnetic recording tape fabricated with magnetic oxide particles, and with oxide and backcoat binders made from polyester urethane was being used for spacecraft tape recorders, and which would periodically manifest operational problems such as layer-to-layer adhesion, stick-slip, and shedding of sticky organic materials. These problems were generally associated with periods of high humidity. An experimental study identified that these problems resulted from hydrolysis of the polyester urethane binders.

  12. Coiffured black rings

    Science.gov (United States)

    Bena, Iosif; Ross, Simon F.; Warner, Nicholas P.

    2014-08-01

    We describe a new type of hair on supersymmetric black string and black ring solutions, which produces the largest known violation of black hole uniqueness, parameterized by an arbitrary function and hence an infinite number of continuous parameters. The new solutions can have non-trivial density profiles for the electric fields along the horizon, and yet have a geometry that is regular, although generically not infinitely differentiable, at the horizon. Both neutral and charged probes can cross the horizon without experiencing divergent forces. We also find restricted examples, parameterized by a few arbitrary continuous parameters, where the charge densities fluctuate but the metric does not and hence is completely differentiable. Our new class of solutions owes its existence to a mechanism reminiscent of the Q-ball: in the simplest examples the metric has more symmetry than the matter that supports it.

  13. Flow structure and heat transfer in a square duct fitted with dual/quadruple twisted-tapes: Influence of tape configuration

    International Nuclear Information System (INIS)

    Eiamsa-ard, S.; Changcharoen, W.

    2015-01-01

    Numerical predictions reported of thermohydraulic characteristics of square ducts equipped with dual and quadruple twisted tapes (DTs and QTs) with different configurations. The studied cases include (1) dual co-tapes (Co-DTs), (2) dual counter-tapes (C-DTs), (3) diagonal dual counter-tapes (C-DDTs), (4) diagonal dual co-tapes (Co-DDTs), (5) quadruple co-tapes (Co-QTs), (6) quadruple counter tapes (CC-QTs) and (7) quadruple counter-tapes (PC-QTs). The results of these cases are compared with those of a smooth duct (a duct without tape insert) and also the one with a single tape (ST). The prediction involves using the RNG k-ε turbulent model under constant wall heat flux condition in the turbulent flow regime for the Reynolds number ranging from 6000 to 14000. The prediction indicates that thermohydraulic characteristics in ducts with twisted tape are strongly dependent on number and configuration of tapes. However, the influence of tape number is more significant than that of tape configuration. Heat transfer and friction increase as tape number increases. QTs offer superior heat transfer to DTs but their thermal performance factors are lower. For the tape inserts determined, DTs with diagonal configuration (Co-DDTs and C-DDTs) is the best design as the tapes offer the best thermal performance. The highest thermal performance factors given by Co-DTs, Co-DDTs, C-DTs, C-DDTs, Co-QTs, PC-QTs and CC-QTs, are around 1.21, 1.35, 1.25, 1.38, 1.08, 1.18, and 1.22, respectively

  14. Kinesio Taping effects on knee extension force among soccer players

    Directory of Open Access Journals (Sweden)

    Maysa V. G. B. Serra

    2015-04-01

    Full Text Available Background : Kinesio Taping (KT is widely used, however the effects of KT on muscle activation and force are contradictory. Objective : To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results : There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666 or among testing sessions (pre, post, and 24h after (F=0.528, p=0.868, and there was no statistical significance (F=0.271, p=0.986 for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension.

  15. The effect of Kinesio Taping on handgrip strength.

    Science.gov (United States)

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C

    2015-03-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18-30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values.

  16. Increasing the efficiency of tape-based storage backends

    CERN Document Server

    Bessone, N; Murray, S; Taurelli, G; CERN. Geneva. IT Department

    2010-01-01

    HSM systems such as the CERN’s Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for incre...

  17. Magnetization loss for stacks of ReBCO tapes

    Science.gov (United States)

    Bykovsky, N.; De Marzi, G.; Uglietti, D.; Bruzzone, P.; Muzzi, L.

    2017-02-01

    The AC loss measurements of the high temperature superconductor (HTS) cable prototype in the EDIPO test facility motivated detailed investigations of the loss contributions from the tape, strand and cable stages of the HTS fusion conductor design proposed at the Swiss Plasma Center. As an initial step of the task, magnetization tests of soldered stacks of HTS tapes were carried out at temperatures of 5 and 77 {{K}} and magnetic fields up to 12 {{T}} using the vibrating sample magnetometer technique. The influence on the magnetization loss of the number of tapes, width of the tape, field’s orientation and tape’s manufacturer is studied experimentally performing both the major and minor magnetization loops with different ramp rates of the applied magnetic field. In order to validate the test results, a numerical model is developed and presented in this work. From the numerical model we also deduced an analytical approach for the magnetization loss in the stacks of tapes with arbitrary number of tapes in the critical state model. Comparison between the measured and estimated magnetization loss of the cable prototypes is reported as well.

  18. Forensic isotope ratio mass spectrometry of packaging tapes.

    Science.gov (United States)

    Carter, James F; Grundy, Polly L; Hill, Jenny C; Ronan, Neil C; Titterton, Emma L; Sleeman, Richard

    2004-12-01

    Pressure sensitive adhesive tape (brown parcel tape) is employed in a great many criminal activities such as the restraint of individuals during robbery and offences against the person, the enclosure of explosive devices and the packaging and concealment of controlled drugs. Packaging materials are ubiquitous in modern society and are produced in such vast quantities that it is increasingly difficult to distinguish between different products or to link materials to a common source. This study demonstrates the potential of stable isotope ratio mass spectrometry to characterise parcel tapes based on a number of properties. The carbon isotopic signature, derived from the substrate polymer, associated additives and adhesive is highly characteristic of a particular tape and allows samples from different sources to be readily distinguished. Further discrimination may be achieved by the incorporation of deuterium and oxygen isotopic data and by analysis of the isolated backing polymer. Recovery of intact tape from simulated forensic samples proved straightforward and the isotopic signature of the tape did not appear to be affected by adverse storage conditions.

  19. Design and Implementation of Automatic Control System for Rice Seed Tape Winding Units

    OpenAIRE

    Cui, Hongguang; Ren, Wentao; Zhang, Benhua; Yang, Yi; Dai, Lili; Xiang, Quanli

    2010-01-01

    International audience; In order to adapt to the requirements of the development for precision agriculture technology, making the rice seed tape planting technology has been widely used. The paper-making improved the design on the rice seed tape twisting machine especially the seed tape winding units. It proposed seed tape winding automatic control system based on STC90C514AD to realize the rotating speed adjustment of the seed tape disk, used an angular displacement sensor real-time detectin...

  20. Black Culture

    Directory of Open Access Journals (Sweden)

    Angela Khristin Brown

    2013-07-01

    Full Text Available The migration of blacks in North America through slavery became united.  The population of blacks past downs a tradition of artist through art to native born citizens. The art tradition involved telling stories to each generation in black families. The black culture elevated by tradition created hope to determine their personal freedom to escape from poverty of enslavement and to establish a way of life through tradition. A way of personal freedoms was through getting a good education that lead to a better foundation and a better way of life.

  1. Recovery of DNA from latent fingerprint tape lifts archived against matte acetate.

    Science.gov (United States)

    Steadman, Shelly A; Hoofer, Steven R; Geering, Sarah C; King, Stephanie; Bennett, Marc A

    2015-05-01

    This study was driven by court order to examine methods to remove, extract, and STR-type potential DNA entrapped between latent fingerprint lifting tape and matte acetate that was collected from a 1977 crime scene. Results indicate that recovery of appreciable quantities of DNA is more challenging once adhesive is attached to matte acetate cards and even more difficult when fixed following black powder enhancement. STR amplification of extracts from entrapped fingermarks collected following the dusting/lifting procedure did not produce robust profiles, and extraneous peaks not expressed by print donors were detected for some samples. A hearing was set to argue whether there was DNA remaining to be tested, and if so, whether that DNA could be exculpatory in this postconviction matter. The studies herein provided the basis for the court's decision to not require the testing. © 2015 American Academy of Forensic Sciences.

  2. Radiographic Outcomes of Postoperative Taping Following Hallux Valgus Correction.

    Science.gov (United States)

    Ponzio, Danielle Y; Pedowitz, David I; Verma, Kushagra; Maltenfort, Mitchell G; Winters, Brian S; Raikin, Steven M

    2015-07-01

    Traditionally, hallux valgus operative correction has been accompanied by serial spica taping of the great toe during the postoperative period. We retrospectively reviewed 187 adult patients who underwent proximal first metatarsal osteotomy with a modified McBride procedure in 2008-2009 (n = 83) and 2011-2012 (n = 104). Postoperatively, to maintain the corrected position of the hallux, patients from 2008 through 2009 underwent weekly spica taping, while patients from 2011 through 2012 utilized a toe separator. The hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured using anteroposterior weight-bearing preoperative, 2-week postoperative non-weight-bearing, and 3-month weight-bearing final follow-up radiographs. A mixed-effects linear regression model identified differences between the treatment groups over time, and a t test compared actual radiographic differences at final follow-up. The mixed-effects model revealed no significant difference in the HVA over time when comparing patients taped to those not taped at the preoperative (33 ± 6 vs 33 ± 6), 2-week postoperative (10 ± 7 vs 9 ± 6), and 3-month follow-up (14 ± 6 vs 11 ± 7) visits (P = .08). At final follow-up, the HVA was lower for the group that was not taped, but the difference (2.5 degrees) was below the minimal clinically important difference (MCID) (P = .015, 95% CI 0.5-4.5). For IMA, there was improved maintenance of correction over time in the patients that were not taped compared to those taped at the preoperative (15 ± 3 vs 15 ± 3), 2-week postoperative (2 ± 2 vs 3 ± 3), and 3-month follow-up (5 ± 4 vs 7 ± 4) visits (P = .002). At final follow-up, the IMA was lower for the group that was not taped, but the difference (1.7 degrees) was below the MCID (P = .004, 95% CI 0.7-2.9). We report no radiographic benefit of postoperative taping after hallux valgus correction. The present study challenges the previous dogma of postoperative spica taping as the protocol is cost and

  3. Dyonic black hole in heterotic string theory

    International Nuclear Information System (INIS)

    Jatkar, D.P.; Mukherji, S.

    1997-01-01

    We study some features of the dyonic black hole solution in heterotic string theory on a six-torus. This solution has 58 parameters. Of these, 28 parameters denote the electric charge of the black hole, another 28 correspond to the magnetic charge, and the other two parameters are the mass and the angular momentum of the black hole. We discuss the extremal limit and show that in various limits it reduces to the known black hole solutions. The solutions saturating the Bogomolnyi bound are identified. An explicit solution is presented for the non-rotating dyonic black hole. (orig.)

  4. Kinesio Tape and Shoulder-Joint Position Sense.

    Science.gov (United States)

    Aarseth, Lindsay M; Suprak, David N; Chalmers, Gordon R; Lyon, Lonnie; Dahlquist, Dylan T

    2015-08-01

    Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Cross-sectional study. University laboratory. A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω(2) = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω(2) = .002), position (ω(2) = .072), and tape by position (ω(2) = .027). At 90° of elevation, shoulder JPS was impaired by the application of KT.

  5. Accelerated aging studies and environmental stability of prototype tamper tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Wright, C.W. [Pacific Northwest Lab., Richland, WA (United States); Bunk, A.R. [Battelle Columbus Lab., OH (United States)] [and others

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  6. Black Cohosh

    Science.gov (United States)

    ... who have had hormone-sensitive conditions such as breast cancer or for pregnant women or nursing mothers. Black cohosh should not be confused with blue cohosh (Caulophyllum thalictroides) , which has different effects and may not be safe. Black cohosh has ...

  7. Development and manufacturing of tape casted, anode-supported solid oxide fuel cells; Entwicklung und Herstellung von foliengegossenen, anodengestuetzten Festoxidbrennstoffzellen

    Energy Technology Data Exchange (ETDEWEB)

    Schafbauer, Wolfgang

    2010-07-01

    Solid oxide fuel cells offer high potential in transforming the chemical energy of hydrogen or natural gas into electrical energy. Due to the high efficiency of fuel cells, lots of effort has been made in the improvement of net efficiency and in materials development during the last years. Recently, the introduction of high performance, low-cost production technologies become more and more important. At the Institute of Energy Research IEF-1 of Forschungszentrum Julich, standard SOFCs were processed by time and work consuming methods. On the way to market entrance, product costs have to be reduced drastically. The aim of this thesis is the introduction of a high efficient low-cost processing route for the SOFC manufacturing. Therefore, the well-known and well established shaping technology tape casting was used for generating the anode substrates. As the first goal of this approach, two different tape casting slurries were developed in order to get substrates in the thickness range from 300 to 500 {mu}m after sintering. After shaping of the substrates, sinter regimes for the different necessary coatings were adapted to the novel substrate types in order to obtain cells with high performance and strength. Therefore, the different coating technologies like screen printing and vacuum slip casting were used for cell manufacturing. The optimization of the different coating steps during cell manufacturing led to high performance SOFCs with a 10% higher power output compared to the Julich state-of-the-art SOFC. Additional experiments verified the workability of the novel tape cast substrates for the manufacturing of near-net-shape SOFC. Finally, the novel cell types based on tape cast substrates were assembled to stacks with up to ten repeating units. Stack tests showed identical performance and degradation compared to stacks containing state-of-the-art SOFCs. Thus, the complete lifetime circle of a SOFC starting from powder preparation to stack assembly has been

  8. Mechanical properties and bending strain effect on Cu-Ni sheathed MgB2 superconducting tape

    International Nuclear Information System (INIS)

    Fu, Minyi; Chen, Jiangxing; Jiao, Zhengkuan; Kumakura, H.; Togano, K.; Ding, Liren; Zhang, Yong; Chen, Zhiyou; Han, Hanmin; Chen, Jinglin

    2004-01-01

    The Young's modulus (E) of Cu-Ni sheathed MgB 2 monofilament tape was measured using electric method. It is about 8.05 x 10 10 Pa, the same order of Cu and its alloys. We found that the lower E value of the MgB 2 component seemed to relate to the lower filament density. The benefits of pre-compression in filaments were discussed in terms of improving stress distribution in the wires and tapes during winding and operation of superconducting magnets. The magnetic field dependence of J c was investigated on the sample subjected to various strain levels through bending with different radii at 4.2 K

  9. Efficient Access to Massive Amounts of Tape-Resident Data

    Science.gov (United States)

    Yu, David; Lauret, Jérôme

    2017-10-01

    Randomly restoring files from tapes degrades the read performance primarily due to frequent tape mounts. The high latency and time-consuming tape mount and dismount is a major issue when accessing massive amounts of data from tape storage. BNL’s mass storage system currently holds more than 80 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on code from Oak Ridge National Lab, developed in the early 2000s. After some major modifications and enhancements, ERADAT now provides advanced HPSS resource management, priority queuing, resource sharing, web-browser visibility of real-time staging activities and advanced real-time statistics and graphs. ERADAT is also integrated with ACSLS and HPSS for near real-time mount statistics and resource control in HPSS. ERADAT is also the interface between HPSS and other applications such as the locally developed Data Carousel, providing fair resource-sharing policies and related capabilities. ERADAT has demonstrated great performance at BNL.

  10. The ultratough peeling of elastic tapes from viscoelastic substrates

    Science.gov (United States)

    Afferrante, L.; Carbone, G.

    2016-11-01

    The peeling of an elastic thin tape from a flat smooth viscoelastic substrate is investigated. Based on a Green function approach and on the translational invariance, a closed form analytical solution is proposed, which takes into account the viscoelastic dissipation in the substrate material. We find that peeling is prevented from taking place, only when the external force is smaller than the one predicted by Kendall's formula for elastic tapes on rigid substrates. However, we also find that, regardless of the value of the applied force, steady state detachment may occur when the elastic tape is sufficiently stiff. In this case, the constant peeling velocity can be modulated by properly defining the geometrical parameters and the material properties of tape and viscoelastic foundation. On the other hand, for relatively high peeling angles or compliant tapes a threshold value of the peeling force is found, above which the steady-state equilibrium is no longer possible and unstable detachment occurs. The present study contributes to shed light on the behavior of pressure sensitive adhesives in contact with viscoelastic substrates like the human skin. At the same time, it can be considered a first step towards a better understanding of the effect of viscoelastic dissipation on the fracture behavior of solids.

  11. Comparison of Tension-free Vaginal Tape Versus Transobturator Tape in Women with Stress Urinary Incontinence

    Directory of Open Access Journals (Sweden)

    Zinat Ghanbari

    2007-06-01

    Full Text Available Objective: This study compared the Tension-free vaginal tape (TVT and Transobturator tape (TOT procedures for surgical treatment of stress urinary incontinence in women.Materials and methods: This prospective non randomized clinical trial was conducted in Vali-e-asr hospital from March 2001 to March 2005. A total of 71 patients with clinical and urodynamic diagnosis of Stress urinary incontinence (SUI were enrolled in the study. Patients were divided into two groups and underwent TVT or TOT procedures. Mean operation time, cure rate, post operative urinary retention, bleeding and infection were compared between two groups. SPSS software was used for statistical analysis. Chi square and fisher exact test calculated the effects of the nominal variables. Mean difference of quantitative variables were compared by student's T- test. P ≤0.05 was considered statistically significant. Results: There was no significant difference in mean time of operation and peri-operative complications among groups. Urinary retention was 13.8% (n=5 in the TVT group versus 2.8% (n=1 in TOT group (NS. The rates of cure (91.6% vs 91.4%, improvement (5.6% vs 8.6% and failure (2.8% vs 0 were similar for the TVT and TOT groups. The rate of hemorrhagic complications was 5.5% in TVT and 2.8% in TOT group (NS.Conclusion: TOT appears to be equally efficient to TVT for surgical treatment of stress urinary incontinence after 30 months follow-up.

  12. Kretschmann Scalar for a Kerr-Newman Black Hole

    OpenAIRE

    Henry, Richard C.

    1999-01-01

    I have derived the Kretschmann scalar for a general black hole of mass m, angular momentum per unit mass a, and electric charge Q. The Kretschmann scalar gives the amount of curvature of spacetime, as a function of position near (and within) a black hole. This allows one to display the "appearance" of the black hole itself, whether the black hole is merely of stellar mass, or is a supermassive black hole at the center of an active galaxy. Schwarzschild black holes, rotating black holes, elect...

  13. Preparation of MgB2 superconducting tapes using electrophoresis

    Science.gov (United States)

    Xu, J. D.; Wang, S. F.; Zhou, Y. B.; Zhou, Y. L.; Chen, Z. H.; Cui, D. F.; Lu, H. B.; He, M.; Dai, S. Y.; Yang, G. Z.

    2002-08-01

    Superconducting MgB2/Ta tapes with a critical temperature of 34 K have been prepared successfully by ex situ annealing of electrophoresis-grown boron in the presence of Mg vapour at 920 °C. Scanning electron microscopy was used to examine the surface morphology of the MgB2/Ta tapes, and well-formed MgB2 crystals with sizes up to 2 μm were observed. The x-ray diffraction patterns showed randomly orientated growth of MgB2 phase in the tapes. Estimates using hysteresis loops and the Bean model give a value of 6.8 × 105 A cm-2 for the critical current density.

  14. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2010-10-15

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  15. Experimental Investigations of Woven Textile Tape as Strain Sensor

    Science.gov (United States)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  16. Folding, stowage, and deployment of viscoelastic tape springs

    DEFF Research Database (Denmark)

    Kwok, Kawai; Pellegrino, Sergio

    2013-01-01

    This paper presents an experimental and numerical study of the folding, stowage, and deployment behavior of viscoelastic tape springs. Experiments show that during folding the relationship between load and displacement is nonlinear and varies with rate and temperature. In particular, the limit...... and propagation loads increase with the folding rate but decrease with temperature. During stowage, relaxation behavior leads to a reduction in internal forces that significantly impacts the subsequent deployment dynamics. The deployment behavior starts with a short, dynamic transient that is followed by a steady...... deployment and ends with a slow creep recovery. Unlike elastic tape springs, localized folds in viscoelastic tape springs do not move during deployment. Finite-element simulations based on a linear viscoelastic constitutive model with an experimentally determined relaxation modulus are shown to accurately...

  17. Mirror-Touch and Ticker Tape Perceptions in Synesthesia

    Directory of Open Access Journals (Sweden)

    Charlotte Anne Chun

    2013-11-01

    Full Text Available A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia’s connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person’s arm being stroked can evoke physical touch sensation on one’s own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker’s mouth. To explore synesthesia’s associations with these phenomena, a diverse group (n=3,743 was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1,017 eligible respondents, synesthetes (across all subtypes reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However effect size was small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2 to 4% and sequence-space synesthesia (9 to 14%. Within synesthesia, grapheme-personification, also called ordinal-linguistic personification was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect

  18. Slowly balding black holes

    International Nuclear Information System (INIS)

    Lyutikov, Maxim; McKinney, Jonathan C.

    2011-01-01

    The 'no-hair' theorem, a key result in general relativity, states that an isolated black hole is defined by only three parameters: mass, angular momentum, and electric charge; this asymptotic state is reached on a light-crossing time scale. We find that the no-hair theorem is not formally applicable for black holes formed from the collapse of a rotating neutron star. Rotating neutron stars can self-produce particles via vacuum breakdown forming a highly conducting plasma magnetosphere such that magnetic field lines are effectively ''frozen in'' the star both before and during collapse. In the limit of no resistivity, this introduces a topological constraint which prohibits the magnetic field from sliding off the newly-formed event horizon. As a result, during collapse of a neutron star into a black hole, the latter conserves the number of magnetic flux tubes N B =eΦ ∞ /(πc(ℎ/2π)), where Φ ∞ ≅2π 2 B NS R NS 3 /(P NS c) is the initial magnetic flux through the hemispheres of the progenitor and out to infinity. We test this theoretical result via 3-dimensional general relativistic plasma simulations of rotating black holes that start with a neutron star dipole magnetic field with no currents initially present outside the event horizon. The black hole's magnetosphere subsequently relaxes to the split-monopole magnetic field geometry with self-generated currents outside the event horizon. The dissipation of the resulting equatorial current sheet leads to a slow loss of the anchored flux tubes, a process that balds the black hole on long resistive time scales rather than the short light-crossing time scales expected from the vacuum no-hair theorem.

  19. The effect of Kinesio Taping on handgrip strength

    OpenAIRE

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Prot?ssio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C.

    2015-01-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18?30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of ta...

  20. The new CERN tape software - getting ready for total performance

    CERN Document Server

    Cano, E; Kruse, D F; Kotlyar, V; Côme, D

    2015-01-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  1. Numerical Modeling of Fluid Flow in the Tape Casting Process

    DEFF Research Database (Denmark)

    Jabbari, Masoud; Hattel, Jesper Henri

    2011-01-01

    The flow behavior of the fluid in the tape casting process is analyzed. A simple geometry is assumed for running the numerical calculations in ANSYS Fluent and the main parameters are expressed in non-dimensional form. The effect of different values for substrate velocity and pressure force...... of the substrate velocity is evaluated. The results of the modeling show that a relatively uniform tape thickness can be achieved. Moreover, the results are compared with selected experimental and analytical data from literature and good agreement is found....

  2. Micromechanics Models for Viscoelastic Plain-Weave Composite Tape Springs

    DEFF Research Database (Denmark)

    Kwok, Kawai; Pellegrino, Sergio

    2017-01-01

    The viscoelastic behavior of polymer composites decreases the deployment force and the postdeployment shape accuracy of composite deployable space structures. This paper presents a viscoelastic model for single-ply cylindrical shells (tape springs) that are deployed after being held folded...... homogenization leads to the lamina relaxation ABD matrix. The accuracy of the proposed model is verified against the experimentally measured time-dependent compliance of single lamina in either pure tension or pure bending. Finite element simulations of single-ply tape springs based on the proposed model...

  3. Black Tea

    Science.gov (United States)

    ... leaves of the same plant, has some different properties. Black tea is used for improving mental alertness ... that slow blood clotting include aspirin, clopidogrel (Plavix), diclofenac (Voltaren, Cataflam, others), ibuprofen (Advil, Motrin, others), naproxen ( ...

  4. A Self-Instructional System in Electricity.

    Science.gov (United States)

    Greene, Mark M.; And Others

    A self-instructional system is presented designed to teach high school students fundamental concepts of electricity and how they are applied in daily life. In six lessons, the student attends to a self-paced slide and tape presentation and makes written responses in the workbooks. A supplementary application problem, requiring the assembly of some…

  5. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    International Nuclear Information System (INIS)

    Gorospe, Alking; Nisay, Arman; Shin, Hyung-Seop

    2014-01-01

    Highlights: • I c degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I c degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I c degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes

  6. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    Science.gov (United States)

    Tallouli, M.; Shyshkin, O.; Yamaguchi, S.

    2017-07-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  7. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    International Nuclear Information System (INIS)

    Tallouli, M; Yamaguchi, S.; Shyshkin, O.

    2017-01-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  8. A carbon nanotube tape for serial-section electron microscopy of brain ultrastructure.

    Science.gov (United States)

    Kubota, Yoshiyuki; Sohn, Jaerin; Hatada, Sayuri; Schurr, Meike; Straehle, Jakob; Gour, Anjali; Neujahr, Ralph; Miki, Takafumi; Mikula, Shawn; Kawaguchi, Yasuo

    2018-01-30

    Automated tape-collecting ultramicrotomy in conjunction with scanning electron microscopy (SEM) is a powerful approach for volume electron microscopy and three-dimensional neuronal circuit analysis. Current tapes are limited by section wrinkle formation, surface scratches and sample charging during imaging. Here we show that a plasma-hydrophilized carbon nanotube (CNT)-coated polyethylene terephthalate (PET) tape effectively resolves these issues and produces SEM images of comparable quality to those from transmission electron microscopy. CNT tape can withstand multiple rounds of imaging, offer low surface resistance across the entire tape length and generate no wrinkles during the collection of ultrathin sections. When combined with an enhanced en bloc staining protocol, CNT tape-processed brain sections reveal detailed synaptic ultrastructure. In addition, CNT tape is compatible with post-embedding immunostaining for light and electron microscopy. We conclude that CNT tape can enable high-resolution volume electron microscopy for brain ultrastructure analysis.

  9. Taping patients with clinical signs of subacromial impingement syndrome: the design of a randomized controlled trial

    NARCIS (Netherlands)

    Kalter, J.; Apeldoorn, A.T.; Ostelo, R.W.J.G.; Henschke, N.; Knol, D.L.; van Tulder, M.W.

    2011-01-01

    Background: Shoulder problems are a common complaint of the musculoskeletal system. Physical therapists treat these patients with different modalities such as exercise, massage, and shoulder taping. Although different techniques have been described, the effectiveness of taping has not yet been

  10. A study of the frictional and stick-slip behavior of magnetic recording tapes

    Science.gov (United States)

    Kalfayan, S. H.; Silver, R. H.; Hoffman, J. K.

    1972-01-01

    Methods were developed to determine the coefficient of friction and the extent of stick-slip of magnetic recording tapes. After a preliminary phase during which experimental procedures were established and screening of candidate tapes was carried out, the frictional and stick-slip behavior of four selected tapes, using four different kinds of magnetic heads, was studied at various temperatures, under dry and humid conditions, and in various gaseous atmospheres, such as argon, helium, nitrogen and air. The effects of tape speed and outgassing on the drag properties of the tapes were also studied. A rank was assigned to each tape and magnetic head as a result of these tests. This study helped in the selection of a magnetic tape in a flight project, and will be useful in the consideration of tapes and magnetic heads for future spacecraft applications.

  11. Asymmetric black dyonic holes

    Directory of Open Access Journals (Sweden)

    I. Cabrera-Munguia

    2015-04-01

    Full Text Available A 6-parametric asymptotically flat exact solution, describing a two-body system of asymmetric black dyons, is studied. The system consists of two unequal counterrotating Kerr–Newman black holes, endowed with electric and magnetic charges which are equal but opposite in sign, separated by a massless strut. The Smarr formula is generalized in order to take into account their contribution to the mass. The expressions for the horizon half-length parameters σ1 and σ2, as functions of the Komar parameters and of the coordinate distance, are displayed, and the thermodynamic properties of the two-body system are studied. Furthermore, the seven physical parameters satisfy a simple algebraic relation which can be understood as a dynamical scenario, in which the physical properties of one body are affected by the ones of the other body.

  12. Transobturator Tape (TOT) for treatment of female stress incontinence

    African Journals Online (AJOL)

    Objective: Evaluation of the transobturator tape (TOT), the newest tension-free technique for the treatment of female stress urinary incontinence (SUI) and its early results with 6 months follow up. Patients and Methods: This study was conducted at King Saud Hospital, Saudi Arabia, between September 2002 and March 2004 ...

  13. Possibilities of Kinesio Taping to Prevent Injuries of Professional Dancers.

    Science.gov (United States)

    Berezutsky, Vladimir

    2018-01-26

    The literature review comprises information about application of kinesio taping in prevention of professional dancers' injuries. The relevance of the study is determined by frequent dance related and overuse injuries and lack of organized information about this issue. The purpose of the study is to assess the impact of kinesio taping on the musculoskeletal system of dancers basing on the scientific research data of the years 2015-2017. The analysis revealed that kinesio taping can effectively reduce muscle spasms, rebuild muscle strength of the injured extremity, improve static and dynamic balance and ease the pain, due to its ability to improve the proprioception of the joints and regulate muscle tone. These effects reduce muscle imbalance and joint instability, thus increasing treatment efficacy and shortening the physical loads limitation. Kinesio taping significantly reduces the risk of overuse syndromes and dance related injuries during dance trainings and strenuous exercises of people with chronic musculoskeletal diseases. Therefore, the mentioned method has proven its broad utility in primary and secondary prevention of dance-related injuries.

  14. Cutting red tape: national strategies for administrative simplification

    National Research Council Canada - National Science Library

    Cerri, Fabienne; Hepburn, Glen; Barazzoni, Fiorenza

    2006-01-01

    ... when the topic was new, and had a strong focus on the tools used to simplify administrative regulations. Expectations are greater today, and ad hoc simplification initiatives have in many cases been replaced by comprehensive government programmes to reduce red tape. Some instruments, such as one-stop shops, which were new then, have become widely adop...

  15. THE EFFECTS OF KINESIO TAPING ON PROPRIOCEPTION AT THE ANKLE

    Directory of Open Access Journals (Sweden)

    Mark DeBeliso

    2004-03-01

    Full Text Available An experiment was designed to determine if KinesioTM taping the anterior and lateral portion of the ankle would enhance ankle proprioception compared to the untaped ankle. 30 subjects, 15 men, 15 women, ages 18-30 participated in this study. Exclusion criteria: Ankle injury < 6 months prior to testing, significant ligament laxity as determined through clinical evaluation by an ATC, or any severe foot abnormality. Experiment utilized a single group, pretest and posttest. Plantar flexion and inversion with 20° of plantar flexion reproduction of joint position sense (RJPS was determined using an ankle RJPS apparatus. Subjects were barefooted, blindfolded, and equipped with headphones playing white noise to eliminate auditory cues. Subjects had five trials in both plantar flexion and inversion with 20° plantar flexion before and after application of the KinesioTM tape to the anterior/lateral portion of the ankle. Constant error and absolute error were determined from the difference between the target angle and the trial angle produced by the subject. The treatment group (KinesioTM taped subjects showed no change in constant and absolute error for ankle RJPS in plantar flexion and 20º of plantar flexion with inversion when compared to the untaped results using the same motions. The application of KinesioTM tape does not appear to enhance proprioception (in terms of RJPS in healthy individuals as determined by our measures of RJPS at the ankle in the motions of plantar flexion and 20º of plantar flexion with inversion.

  16. Facilitatory and inhibitory effects of Kinesio tape: Fact or fad?

    Science.gov (United States)

    Cai, C; Au, I P H; An, W; Cheung, R T H

    2016-02-01

    Kinesio tape (KT) is a commonly used intervention in sports. It claims to be able to alter the muscle activity, in terms of both facilitation and inhibition, by certain application methods. This study compared the neuromuscular activity of the wrist extensor muscles and maximal grip strength with facilitatory, inhibitory KT, and tapeless condition in healthy adults who were ignorant about KT. Potential placebo effects were eliminated by deception. Randomized deceptive trial. 33 participants performed maximal grip assessment in a randomly assigned order of three taping conditions: true facilitatory KT, inhibitory KT, and no tape. The participants were blindfolded during the evaluation. Under the pretense of applying a series of adhesive muscle sensors, KT was applied to their wrist extensor muscles of the dominant forearm in the first two conditions. Within-subject comparisons of normalized root mean square of the wrist extensors electromyographic activity and maximal grip strength were conducted across three taping conditions. 31 out of 33 enlisted participants were confirmed to be ignorant about KT. No significant differences were found in the maximum grip strength (p=0.394), electromyographic activity (p=0.276), and self-perceived performance (p=0.825) between facilitatory KT, inhibitory KT, and tapeless conditions. Neither facilitatory nor inhibitory effects were observed between different application techniques of KT in healthy participants. Clinically, alternative method should be used for muscle activity modulation. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Cervical ectopic pregnancy: Mersilene tape in surgical management

    African Journals Online (AJOL)

    2 Division of Obstetrics and Gynaecology, Mediclinic Hospital, Nelspruit, Mpumalanga, South Africa. Corresponding author: A A ... case of cerv ical ectopic pregnancy that was managed using cervical cerclage with Mersilene tape as an interven tion to reduce intraoperative haemorrhage during evacuation. Case report.

  18. Numerical modeling of laser assisted tape winding process

    NARCIS (Netherlands)

    Zaami, Amin; Baran, Ismet; Akkerman, Remko

    2017-01-01

    Laser assisted tape winding (LATW) has become more and more popular way of producing new thermoplastic products such as ultra-deep sea water riser, gas tanks, structural parts for aerospace applications. Predicting the temperature in LATW has been a source of great interest since the temperature at

  19. Carbon tape microsampling for non-destructive analyses of artefacts

    Czech Academy of Sciences Publication Activity Database

    Bartůněk, V.; Varadzin, Ladislav; Zavřel, Jan

    -, - (2017) ISSN 1866-9557 R&D Projects: GA ČR(CZ) GAP405/10/2334 Institutional support: RVO:67985912 Keywords : microsampling * SEM-EDS * conducting SEM carbon tape * non-ferrous metallurgy * moulds * Early Middle Ages Subject RIV: AC - Archeology, Anthropology, Ethnology OBOR OECD: Archaeology Impact factor: 1.844, year: 2016

  20. Cervical ectopic pregnancy: Mersilene tape in surgical management ...

    African Journals Online (AJOL)

    In view of the rarity of cervical ectopic gestation and the potentially high morbidity that may be associated with its presentation and management, we report management of a case of cervical ectopic pregnancy using cervical cerclage with Mersilene tape as an intervention to reduce intraoperative haemorrhage during ...

  1. Modeling and Velocity Tracking Control for Tape Drive System ...

    African Journals Online (AJOL)

    The objectives of this paper are to formulate mathematical model for the tape drive system (TDS) by designing velocity tracking controller using physical laws. A Matlab function script and Simulink model were developed in Matlab and Simulink environment. The result of the study revealed that 7.07, 8 and 10 of koln values ...

  2. Modeling and Velocity Tracking Control for Tape Drive System ...

    African Journals Online (AJOL)

    ADOWIE PERE

    2018-03-23

    Mar 23, 2018 ... ABSTRACT: The objectives of this paper are to formulate mathematical model for the tape drive system (TDS) by designing velocity tracking controller using physical laws. A Matlab function script and Simulink model were developed in Matlab and Simulink environment. The result of the study revealed that ...

  3. Standard Practice for Sampling for Particulate Contamination by Tape Lift

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques. 1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing. 1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice. 1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested or for which the susceptibility to damage is unknown is not recommended. In general, metal...

  4. Mechanisms of x-ray emission from peeling adhesive tape

    Science.gov (United States)

    Constable, E.; Horvat, J.; Lewis, R. A.

    2010-09-01

    It has previously been reported that x-rays are emitted when adhesive tape is peeled in a vacuum but no account of the dependence of the x-ray emission on the pressure of the environment has been given to date. In this paper we present detailed experimental data on the number and angular distribution of x-ray photons as a function of pressure. We find that x-rays are emitted for pressures between p0=10-3 and p1=10-2 mBar, with ˜106 counts/(cm2 s) recorded by a 256×256 pixel2 silicon array sensor placed 35 mm from the tape. The main role of the tape is found to be the build-up of an acceleration potential sufficient to produce x-rays by bremsstrahlung of free electrons in a low-pressure gas. The source of the free electrons is the gas. Our model shows that the production rate of uncompensated tape charge and absorption of positive ions from the gas define p1. The angular distribution of the radiation shows a pressure-independent 20° wide peak in the direction perpendicular to electron motion. Ordinary bremsstrahlung cannot describe this peak.

  5. Comparison of scale weights to tape estimates and their ...

    African Journals Online (AJOL)

    Comparison of scale weights to tape estimates and their relationships with condition scores in Bunaji Cattle. RI Mani, AR Abdullahi, R Von Kaufmann. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE ...

  6. Fabrication of laminated Bi-2212/Ag multifilamentary tape

    Science.gov (United States)

    Yuan, D.-W.; Majer, W. J.; Francavilla, T. L.

    2000-03-01

    The powder-in-tube (PIT) process has been successfully used to make long lengths of Ag-sheathed oxide superconductors. A modified PIT approach is proposed to fabricate conductors with laminated Bi-2212 configurations. Ag/Bi-2212 tapes consisting of seven laminae were produced with various thicknesses ranging from 0.38 to 0.25 mm. The use of a turkshead was found to be beneficial, yielding tapes with good dimensional integrity and consistency. Critical current density (Jc ) values greater than 105 A cm-2 (0.01 T and Bicons/Journals/Common/perp" ALT="perp" ALIGN="TOP"/> tape surface) have been attained for tapes of different thicknesses. Nonetheless, Jc was found to be related to the average thickness of individual Bi-2212 lamina. It is believed that excessive cold working accounts for the decrease in Jc with decreasing size below a threshold value. The enhancement of Jc is attributed to the high Bi-2212 grain alignment along the Ag-oxide interfaces and uniform dimensions within the laminate conductors.

  7. Scotch-Tape Mirror for Hard X-rays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Scotch-Tape Mirror for Hard X-rays project is to test the possibility of building a grazing incidence mirror for hard X-rays (E>20 keV) using a “scotch-tape”...

  8. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    Augmentation of convective heat transfer in internal flows with tape inserts in tubes is a well-acclaimed technique employed ...... Her research interests include IC Engines, Combustion modeling, Alternate fuels, Heat transfer, Refrigeration and Air-conditioning. She has published more than 8 papers in International journals.

  9. Heat conduction and thermal stabilization in YBCO tape

    Indian Academy of Sciences (India)

    †Shibli National College, Azamgarh 276 131, India. MS received 20 April 2011; ... profile along the length of HTS tape under a given energy (joule heating) such that propagation of the hot spot devel- oped locally can be prevented ... diction is best described by carrying out a thermal conduc- tion of the initial quench zone ...

  10. Researchers wrangle petabytes of data storage with NAS, tape

    CERN Multimedia

    Pariseau, Beth

    2007-01-01

    "Much is made in the enterprise data storage industry about the performance of disk systems over tape drives, but the managers of one data center that has eached the far limits of capacity say otherwise. Budget and performance demands forced them to build access protocols and data management tools for disk systems from scratch."

  11. Errors in measurement of current distribution in a superconducting tape

    Science.gov (United States)

    Usak, Pavol

    2011-04-01

    The paper reports on the role of the typical mapping errors in measurement of the lateral sheet current distribution Iy(x) in a superconducting tape. The sheet current is calculated indirectly, from the mapped data of the self magnetic field of the superconducting layer. The field is generated by transport or induced current in a tape. In model calculations examples of the influence of the different types of errors on false shaping of the lateral sheet current profile are given. The field mapping is made outside and over the tape. The lateral profile Bz(x, z) of the magnetic field component, perpendicular to the superconducting layer, is input to the Biot-Savart inverse procedure. In the experiment we have used superconducting tape as a sample and an InSb Hall probe with active surface 20 × 20 µm2 as a magnetic field sensor. We demonstrate the details, together with obstacles and errors encountered in measurement and subsequent evaluation. The demonstrations serve for the reader to be aware of limits in interpretation of the measured data and to overcome the natural barrier in understanding, insight and use of this fruitful method.

  12. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Science.gov (United States)

    2010-02-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. AA1921-167 (Third Review)] Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade Commission. ACTION: Revised schedule for the subject review. DATES: Effective Date: February 16, 2010. FOR FURTHER INFORMATION CONTACT: Edward...

  13. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    Enhancement of heat transfer using varying width twisted tape inserts. ... International Journal of Engineering, Science and Technology ... The present work shows the results obtained from experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted ...

  14. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  15. Effect of kinesio taping on explosive muscle power of gluteus ...

    African Journals Online (AJOL)

    Objective. To determine the short-term effect of kinesio tape on the explosive gluteus maximus power of male athletes, comparing a recommended application pattern with a placebo. Methods. Sixty healthy university male athletes participated in this double-blinded randomised controlled trial. Those athletes with ...

  16. Playback Station #2 for Cal Net and 5-day-recorder tapes

    Science.gov (United States)

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  17. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    OpenAIRE

    Brendon A. Parsons; Olivia Lin Smith; Myeong Chae; Veljko Dragojlovic

    2015-01-01

    Summary In a PTFE tape phase-vanishing reaction (PV-PTFE), a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better...

  18. The Relationship between Phonological Features in Oral Reading and Reading Comprehension of Black West Indians.

    Science.gov (United States)

    Sundre, Donna; Karlin, Andrea

    A study investigated the relationship between phonological features in the oral reading of black West Indians and their reading comprehension. Subjects were 54 college students at the College of the Virgin Islands, St. Thomas. Each subject was recorded reading two passages and completed two cloze tests. The tapes then were analyzed for nine…

  19. Particle creation by charged black holes.

    Science.gov (United States)

    Khriplovich, I. B.

    1999-10-01

    A simple derivation is given for the leading term (n = 1) in the Schwinger formula for the pair creation by a constant electric field. The same approach is applied then to the charged particle production by a charged black hole. In this case, as distinct from that of a constant electric field, the probability of the charged particle production depends essentially on the particle energy. The production rate by black holes is found in the nonrelativistic and ultrarelativistic limits. The range of values for the mass and charge of a black hole is indicated where the discussed mechanism of radiation dominates the Hawking one.

  20. Lessons Learned in High Frequency Data Transmission Design: ATLAS Strips Bus Tape

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00213647; The ATLAS collaboration; Fadeyev, Vitaliy; Grillo, Alexander; Martinez-McKinney, George Forest; Phillips, Peter William; Sawyer, Craig; Sullivan, Stephanie W; Wastie, Roy; Weidberg, Anthony; Nielsen, Jason

    2016-01-01

    Requirements of HEP experiments lead to highly integrated systems with many electrical, mechanical and thermal constraints. A complex performance optimisation is therefore required. High speed data transmission lines are designed using copper-polyimide flexible bus tapes rather than cable harnesses to minimize radiation length. Methods to improve the signal integrity of point-to-point links and multi-drop configurations in an ultra-low-mass system are described. FEA calculations are an essential guide to the optimisation which allow data rates of 640 Mbps for point-to-point links over a length of up to 1.4m, as well as 160 Mbps for multi-drop configuration. The designs were validated using laboratory measurements of S-parameters and direct BER tests.

  1. Ultrasound assessment of tension-free vaginal tape (TVT).

    Science.gov (United States)

    Flock, F; Kohorst, F; Kreienberg, R; Reich, A

    2011-01-01

    To date, no standardization for the visualization of tension-free vaginal tape (TVT) has been established in clinical practice. The aim of this prospective observational study was to evaluate the shape and position of the tape using ultrasound and to compare this data with clinical postoperative results. In a three-year period, 296 patients with clinically and urodynamically proven stress urinary incontinence (SUI) were treated with TVT and received follow-up in our department. An additional 12 patients, who were initially treated in other hospitals and had postoperative problems, were included in this study. Depending on the outcome after 3 months, the patients were divided into groups with and without specific disorders. The TVT was evaluated by introital ultrasound. The position of the tape was established by its location in relation to the urethral length and the distance to the hypoechoic center of the urethra (HCU). A suitable TVT position was determined in patients without any postoperative disorders. The mean value for the TVT position at rest in relation to the urethral length was 61 %. The distance to the HCU was 4.6 ± 1.5 mm. In patients with persistent SUI, the tape was more often located under the inner (3 % vs. 0 %) or outer quarter (29 % vs. 13 %, p = 0.004). In patients with residual volume, the distance to the urethra was significantly lower (2.7 vs. 4.6, p TVT may be regularly investigated using ultrasound. In combination with the clinical outcome, it represents an important method of evaluating the tape and assists in the planning of a future therapeutic course of action in cases of postoperative problems. © Georg Thieme Verlag KG Stuttgart · New York.

  2. High-throughput DNA extraction of forensic adhesive tapes.

    Science.gov (United States)

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. Copyright © 2016 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  3. Temporary ectropion therapy by adhesive taping: a case study

    Directory of Open Access Journals (Sweden)

    Habermann Anke

    2008-07-01

    Full Text Available Abstract Introduction Various surgical procedures are available to correct paralytic ectropion, which are applied in irreversible facial paresis. Problems occur when facial paresis has an unclear prognosis, since surgery of the lower eyelid is usually irreversible. We propose a simple method to correct temporary ectropion in facial palsy by applying an adhesive strip. Patients and methods Ten patients with peripheral facial paresis and paralytic ectropion were treated with an adhesive strip to correct paralytic ectropion. We used "Steri-Strips" (45 × 6.0 mm, which were taped on the carefully cleaned skin of the lower eyelid and of the adjacent zygomatic region until the prognosis of the paresis was clarified. In addition to the examiner's evaluation of the lower lacrimal point in the lacrimal lake, subjective improvement of the symptoms was assessed using a visual analogue scale (VAS, 1–10. Results 9 patients reported a clear improvement of the symptoms after adhesive taping. There was a clear regression of tearing (VAS (median = 8; 1 = no improvement, 10 = very good improvement, the cosmetic impairment of the adhesive tape was low (VAS (median = 2.5; 1 = no impairment, 10 = severe impairment and most of the patients found the use of the adhesive strip helpful. There was slight reddening of the skin in one case and well tolerated by the facial skin in the other cases. Conclusion The cause and location of facial nerve damage are decisive for the type of surgical therapy. In potentially reversible facial paresis, procedures should be used that are easily performed and above all reversible without complications. Until a reliable prognosis of the paresis can be made, adhesive taping is suited for the temporary treatment of paralytic ectropion. Adhesive taping is simple and can be performed by the patient.

  4. OBSERVATION AND DEMONSTRATION IN TEACHER EDUCATION BY CLOSED CIRCUIT TELEVISION AND VIDEO TAPE RECORDINGS.

    Science.gov (United States)

    SANDEFUR, J.T.; AND OTHERS

    THIS PROJECT WAS DESIGNED TO (1) ASSESS THE FEASIBILITY OF A COOPERATIVE EFFORT IN THE USE OF VIDEO TAPE RECORDINGS BETWEEN A STATE INSTITUTION AND PRIVATE LIBERAL ARTS COLLEGES, (2) TO EVALUATE VIDEO TAPE RECORDINGS AS A TOOL IN TEACHER EDUCATION, AND (3) TO EVALUATE INTERACTION ANALYSIS AS AN OBSERVATIONAL TOOL IN VIEWING VIDEO TAPE RECORDINGS…

  5. The effectiveness of kinesio taping for athletes with medial elbow epicondylar tendinopathy.

    Science.gov (United States)

    Chang, H-Y; Cheng, S-C; Lin, C-C; Chou, K-Y; Gan, S-M; Wang, C-H

    2013-11-01

    Kinesio taping has also been used for athletes with Medial Elbow Epicondylar Tendinopathy (MET) as an additional treatment method. The purpose of this study was to determine the clinical effectiveness of Kinesio tape on maximal grip strength and absolute and related force sense in athletes with MET when applied to the medial forearm. 27 male athletes who voluntarily participated in this study were divided into a healthy group (n=17) and a MET group (n=10). All subjects were assessed for the maximal grip strength and grip force sense (absolute and related force sense) under 3 taping conditions: 1) without taping; 2) with placebo Kinesio taping; and 3) with Kinesio taping. No significant interaction was found between groups and taping condition in maximal grip force and related force sense error, except for absolute force sense error (p=0.04). Both groups with absolute force sense measurements had significantly decreased errors in the placebo Kinesio taping and Kinesio taping conditions. Both taping may enhance discrimination of magnitude of grip force control (absolute force sense) in both groups when applied to the forearm. However, Kinesio taping did not change maximal grip strength in either group. The effects of Kinesio taping on other muscle functions remain to be studied. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Effect of two different kinesio taping techniques on knee kinematics and kinetics in young females.

    Science.gov (United States)

    Guner, Senem; Alsancak, Serap; Koz, Mitat

    2015-10-01

    [Purpose] The application of kinesio taping may improve strength and performance, inhibit and facilitate motor activity, and increase range of motion. The aim of this study was to compare the effects of kinesio taping facilitation and inhibition applications on spatiotemporal knee kinematics and kinetics during walking activity in healthy subjects. [Subjects and Methods] A three-dimensional quantitative gait evaluation was performed without tape and with, facilitation and inhibition kinesio taping application on the knee. Sixteen healthy female college students (age, 19.7 ± 0.4 years; height, 1.64 ± 3.4 cm; body mass, 51.5 ± 4.8 kg) participated in the study. [Results] Spatiotemporal parameters (cadence, walking speed, stride length) were significantly different among the trials. Knee joint sagittal plane range of motion was not different with either kinesio taping application. Knee external flexion moment during the early stance phase decreased significantly with facilitation kinesio taping and increased with the inhibition kinesio taping. Knee external extension moment during the mid-stance phase increased with facilitation kinesio taping. Knee power parameters, eccentric activity in the rectus femoris during the pre-swing phase was significantly increased with inhibition kinesio taping application, while eccentric activity of the hamstrings during the terminal swing of gait was decreased. [Conclusion] These findings showed that facilitation kinesio taping application affected the terminal stance phase and that inhibition kinesio taping influenced the terminal swing phase compared with the no tape condition.

  7. BEYOND THE RULES : THE EFFECT OF OUTCOME FAVOURABILITY ON RED TAPE PERCEPTIONS

    NARCIS (Netherlands)

    Kaufmann, Wesley; Feeney, Mary K.

    The underlying reasoning of much red tape research is that the level of rule burden, in terms of resources expended at implementing and complying with specific rules, is the main driver of red tape perceptions. In this study we challenge this claim and argue that stakeholder red tape perceptions are

  8. AC loss analysis of a HTS coil with parallel superconducting tapes of unbalanced current distribution

    International Nuclear Information System (INIS)

    Lee, S.; Byun, S.; Kim, W.; Choi, K.; Lee, H.

    2007-01-01

    Considering the current capacities of the HTS tapes recently being developed, it is inevitable to use these HTS tapes in parallel in order to apply them to power transformers. But non-uniform distributions of current and large AC losses are major problems in a HTS coil with parallel superconducting tapes. Many parallel HTS tapes have been fabricated and tested so far. The results showed that we had to transpose each tape in order to reduce AC losses and have uniform distributions of current. But the measurement of the current distribution process has been quite difficult not only in the case of the parallel HTS tapes but also in the case of the coil with parallel HTS tapes. In our study, we investigated the effect of current distribution on the AC losses in parallel HTS tapes and coils with parallel superconducting tapes. The current distribution in parallel HTS tapes could be measured with small Hall sensors, the dependence of AC losses and critical current on the current distribution was analyzed. We fabricated a parallel HTS tape and HTS coil with the transposed parallel HTS tapes for an application of a power transformer. The performance of non-uniform current distribution in the parallel HTS wires is worse than that of a uniform one

  9. Visualization of Wave Propagation and Fine Structure in Frictional Motion of Unconstrained Soft Microstructured Tapes

    DEFF Research Database (Denmark)

    Heepe, Lars; Filippov, Alexander E.; Kovalev, Alexander E.

    2017-01-01

    We performed friction experiments of soft microstructured tapes, which adhere to a smooth and rigid substrate without further constraint. One side of the tapes was pulled parallel to the substrate allowing the tapes to be stretched, thus changing the frictional dynamics. This essentially differs ...

  10. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  11. The effect of Kinesio® taping on pain, functionality, mobility and endurance in the treatment of chronic low back pain: A randomized controlled study.

    Science.gov (United States)

    Köroğlu, Fahri; Çolak, Tuğba Kuru; Polat, M Gülden

    2017-09-22

    Low back pain is one of the most important causes of morbidity. This study was designed to evaluate the effect of Kinesio® taping on pain, functionality, mobility and endurance in chronic low back pain treatment. Patients with chronic low back pain were randomly divided into three groups. Therapeutic ultrasound, hot packs, and transcutaneous electrical nerve stimulation were applied to each group for ten sessions during two weeks, and therapeutic exercises were applied in the clinic under physiotherapist supervision starting from the sixth session. Kinesio® tape was applied to the patients in the first group after each treatment session, and placebo tape was applied to the patients in the second group. No taping was applied to the third group, which constituted the control group. All the patients were evaluated pre and post-treatment in respect of pain, functional status (Oswestry scale), flexibility and endurance. The study included 60 patients (32 females). When the initial demographic and clinical characteristics of the groups were evaluated, all assessment results, except the Oswestry scores, were similar (p= 0.000). When the average changes in the clinical evaluations were evaluated after the treatment, a statistically significant improvement demonstrating the superiority of the taping group was observed in pain, functionality, flexibility and endurance values (p= 0.000, 0.000, 0.000, 0.000). Kinesio® taping in chronic low back pain is an easy and effective method which increases the effectiveness of the treatment significantly in a short period when applied in addition to exercise and electrotherapy methods.

  12. Surface effects in black hole physics

    International Nuclear Information System (INIS)

    Damour, T.

    1982-01-01

    This contribution reviews briefly the various analogies which have been drawn between black holes and ordinary physical objects. It is shown how, by concentrating on the properties of the surface of a black hole, it is possible to set up a sequence of tight analogies allowing one to conclude that a black hole is, qualitatively and quantitatively, similar to a fluid bubble possessing a negative surface tension and endowed with finite values of the electrical conductivity and of the shear and bulk viscosities. These analogies are valid simultaneously at the levels of electromagnetic, mechanical and thermodynamical laws. Explicit applications of this framework are worked out (eddy currents, tidal drag). The thermostatic equilibrium of a black hole electrically interacting with its surroundings is discussed, as well as the validity of a minimum entropy production principle in black hole physics. (Auth.)

  13. Immediate Effects of Ankle Balance Taping with Kinesiology Tape for Amateur Soccer Players with Lateral Ankle Sprain: A Randomized Cross-Over Design.

    Science.gov (United States)

    Kim, Myoung Kwon; Shin, Young Jun

    2017-11-21

    BACKGROUND The objective of this study was to investigate the immediate effect on gait function when ankle balance taping is applied to amateur soccer players with lateral ankle sprain. MATERIAL AND METHODS A cross-over randomized design was used. Twenty-two soccer players with an ankle sprain underwent 3 interventions in a random order. Subjects were randomly assigned to ankle balance taping, placebo taping, and no taping groups. The assessment was performed using the GAITRite portable walkway system, which records the location and timing of each footfall during ambulation. RESULTS Significant differences were found in the velocity, step length, stride length, and H-H base support among the 3 different taping methods (pamateur soccer players with lateral ankle sprain. Therefore, ankle balance taping is a useful alternative to prevent and treat ankle sprain of soccer players.

  14. Argonne Tape Production Facility systems descriptions. [For generating properly formatted magnetic tapes for Argonne Braille Machine; TAP22, TAP24, TAP25

    Energy Technology Data Exchange (ETDEWEB)

    Foster, R.; Lidinsky, W.

    1977-06-01

    This memorandum describes the operation of the Tape Production Facility. After a brief overview, first the system hardware and then the system software are described. The software consists of two parts: the systems software for the Tape Production Facility and microcode that executes on a SMS Microcontroller. The Microcontroller and some interface hardware implement a dual incremental digital tape transport controller. Logic diagrams and listings for all software are also given. 8 figures.

  15. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people.

    Science.gov (United States)

    Huang, Chen-Yu; Hsieh, Tsung-Hsun; Lu, Szu-Ching; Su, Fong-Chin

    2011-08-11

    Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively) were recruited. All participants performed vertical jump tests prior to (without taping) and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape.

  16. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people

    Directory of Open Access Journals (Sweden)

    Lu Szu-Ching

    2011-08-01

    Full Text Available Abstract Background Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Methods Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively were recruited. All participants performed vertical jump tests prior to (without taping and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. Results The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Conclusions Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape.

  17. Conductivity bound from dirty black holes

    Energy Technology Data Exchange (ETDEWEB)

    Bitaghsir Fadafan, Kazem, E-mail: bitaghsir@shahroodut.ac.ir

    2016-11-10

    We propose a lower bound of the dc electrical conductivity in strongly disordered, strongly interacting quantum field theories using holography. We study linear response of black holes with broken translational symmetry in Einstein–Maxwell-dilaton theories of gravity. Using the generalized Stokes equations at the horizon, we derive the lower bound of the electrical conductivity for the dual two dimensional disordered field theory.

  18. On the properties evolution of engineered surfaces of thin reinforced thermoplastic tapes during consolidation

    Science.gov (United States)

    Leon, Angel; Perez, Marta; Barasinski, Anais; Abisset-Chavanne, Emmanuelle; Chinesta, Francisco

    2017-12-01

    Advanced thermoplastic composite materials look to add functional properties to the mechanical ones, the latter usually ensured by the continuous fibers involved in the composite preforms. For that purpose the use of reinforced thermoplastic resins are being considered. These resins usually integrate manometric particles, with a variety of shapes (rods, spheres, discs, ...) with enhanced functional properties, ensuring for example the increase of thermal or electrical conductivities. However, even when considering adequate particles distribution and orientation in the preforms, forming processes induced properties cannot be ignored and they are particuarly critical at the ply interfaces level, where the degree of intimate contact must be maximized while ensuring equivalent functional properties to the ones existing in the bulk. One possibility for maximizing the intimate contact and at the same time controlling the induced functional anisotropy consists of designing engineered surfaces consolidated by the combined action of temperature and pressure. The combined effect results in a microscopic flow that induces at its turn the evolution of the position and orientation of the particles, and consequently the evolution of the associated properties, e.g. thermal and electrical conductivities. In the present work we address a simplified modeling framework of the functional properties evolution during the consolidation of unidirectional tapes. It combines the squeeze flow modeling, the flow induced microstructural anisotropy and its impact on the thermal and electrical conductivities.

  19. Black Willow

    Science.gov (United States)

    R. M. Krinard

    1980-01-01

    Black willow and other species of Salix together comprise a majority of the stocking. Cottonwood is the chief associate, particularly in the early stages, but green ash, sycamore, pecan, persimmon, waterlocust, American elm, baldcypress, red maple, sugarberry, box-elder, and in some areas, silver maple are invaders preceding the next successional stage.

  20. Counseling Blacks

    Science.gov (United States)

    Vontress, Clemmont E.

    1970-01-01

    Blacks have developed unique environmental perceptions, values, and attitudes, making it difficult for counselors to establish and maintain positive rapport. This article examines attitudinal ingredients posited by Carl Rogers for relevance to this problem, and suggests in-service training to help counselors and other professionals relate…

  1. Black Psyllium

    Science.gov (United States)

    ... by mouth for up to 6 weeks reduces blood sugar in people with type 2 diabetes. Cancer. Diarrhea. Irritable bowel syndrome (IBS). Other conditions. ... with the dose. Diabetes: Black psyllium can lower blood sugar levels ... with type 2 diabetes by slowing down absorption of carbohydrates. Monitor blood ...

  2. Kinesio taping of the deltoid does not reduce fatigue induced deficits in shoulder joint position sense.

    Science.gov (United States)

    Zanca, Gisele G; Mattiello, Stela M; Karduna, Andrew R

    2015-11-01

    Muscle fatigue is known to decrease shoulder proprioceptive acuity, potentially contributing to injuries. It has been suggested that Kinesio taping can improve proprioception. Therefore, the aim of this study was to investigate the effects of Kinesio taping on shoulder joint position sense after muscle fatigue. Twenty-four healthy subjects were evaluated in a randomized, crossover, single-blind study design. Shoulder joint position sense was assessed during active repositioning tests at the target angles of 50°, 70° and 90° of arm elevation in scapular plane, in three sessions: control (no taping), Kinesio taping (Kinesio taping applied over the deltoid muscle with tension) and sham (Kinesio taping applied over deltoid without tension). Joint position sense was assessed three times: before taping; following taping application or rest, in the control session; and following a fatigue protocol. The constant error (repositioned angle-target angle) was considered for statistical analysis, using a 3-way repeated-measure ANOVA (within subject factors: taping, time and target angle). There was no interaction or main effect involving taping. An interaction between time and angle was found and the simple effect showed that the constant error increased following fatigue at 70° and 90°, but not at 50°. The results of this study does not support the use of Kinesio taping applied over the deltoid muscle for compensating or preventing shoulder joint position sense deficits caused by muscle fatigue of shoulder abductors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Black hole astrophysics

    International Nuclear Information System (INIS)

    Blandford, R.D.; Thorne, K.S.

    1979-01-01

    Following an introductory section, the subject is discussed under the headings: on the character of research in black hole astrophysics; isolated holes produced by collapse of normal stars; black holes in binary systems; black holes in globular clusters; black holes in quasars and active galactic nuclei; primordial black holes; concluding remarks on the present state of research in black hole astrophysics. (U.K.)

  4. Quantum black holes

    CERN Document Server

    Calmet, Xavier; Winstanley, Elizabeth

    2014-01-01

    Written by foremost experts, this short book gives a clear description of the physics of quantum black holes. The reader will learn about quantum black holes in four and higher dimensions, primordial black holes, the production of black holes in high energy particle collisions, Hawking radiation, black holes in models of low scale quantum gravity and quantum gravitational aspects of black holes.

  5. Technical and economical evaluation of tape drip and drip line irrigation systems in a strawberry greenhouse

    Directory of Open Access Journals (Sweden)

    Soghra HOSSEINIAN

    2016-04-01

    Full Text Available This study was done in a strawberry greenhouse to examine the technical and the economical evaluation of two drip irrigation systems including the tape and the drip line in the northern part of Iran. The result showed that all of the technical indices with tape were higher than drip line, and due to statistical analysis reveal a significant difference (P < 0.05. Yield and water productivity (WP with tape were higher than drip line (P < 0.05. Benefit per drop (BPD and net benefit per drop (NBPD with tape were higher than drip line. Net present value, internal rate of capital return and benefit to cost ratio in drip line were higher than tape. In general, regarding technical evaluation tape was better than drip line, besides according to the economical evaluation the drip ­lines were better than tape.

  6. Effects of proprioceptive sense-based Kinesio taping on walking imbalance.

    Science.gov (United States)

    Park, Young-Han; Lee, Jung-Ho

    2016-11-01

    [Purpose] The aim of this study was to determine how application of Kinesio tape to the upper and lower limbs affects walking through stimulation of the proprioceptive sense. [Subjects and Methods] Twelve patients diagnosed with hemiplegia due to stroke were selected as the subjects of the study. To ascertain the effects of Kinesio taping on walking, all subjects performed a straight line walking test three times while barefoot. In terms of the actual taping application, elastic Kinesio tape was used on the hemiplegic side in all subjects. [Results] The results of testing showed a significant difference in the values between before and after taping. In terms of left and right deviation according to the site of the taping application, there were statistically significant differences among the groups. [Conclusion] In conclusion, application of Kinesio taping for central nerve injury was confirmed to be effective in reducing walking deviation.

  7. The effects of trunk kinesio taping on balance ability and gait function in stroke patients.

    Science.gov (United States)

    Lee, Yang Jin; Kim, Ji Young; Kim, Seong Yoel; Kim, Kyung Hoon

    2016-08-01

    [Purpose] Kinesio taping is a therapeutic method used in the treatment of various musculoskeletal and neuromuscular deficits, but there is limited evidence of the effects of trunk kinesio taping in neurologic patients. Therefore, this study aimed to determine the effects of trunk kinesio taping on balance ability and gait function in persons after a stroke. [Subjects and Methods] Twenty-five post-stroke patients were included in this study. Kinesio tape was applied to four trunk muscles. Before and after the taping, in all subjects, the balance ability was measured using the Wii Balance Board, and gait function was assessed using the GAITRite system. [Results] The difference in gait function before and after trunk taping was not statistically significant. However, a variability of balance ability showed statistically significant differences. [Conclusion] These results suggest that taping may be a helpful method during rehabilitation programs for stroke patients. Its application to the trunk muscles is especially useful for improving balance ability.

  8. Simulation of magnetization and levitation characteristics of HTS tape stacks

    Science.gov (United States)

    Anischenko, I. V.; Pokrovskii, S. V.; Mineev, N. A.

    2017-12-01

    In this work it is presented a computational model of a magnetic levitation system based on stacks of high-temperature second generation superconducting tapes (HTS) GdBa2Cu3O7-x. Calculated magnetic field and the current distributions in the system for different stacks geometries in the zero-field cooling mode are also presented. The magnetization curves of the stacks in the external field of a permanent NdFeB magnet and the levitation force dependence on the gap between the magnet and the HTS tapes stack were obtained. A model of the magnetic system, oriented to levitation application, is given. Results of modeling were compared with the experimental data.

  9. Kinesthetic taping improves walking function in patients with stroke

    DEFF Research Database (Denmark)

    Boeskov, Birgitte; Carver, Line Tornehøj; von Essen-Leise, Anders

    2014-01-01

    BACKGROUND: Stroke is an important cause of severe disability and impaired motor function. Treatment modalities that improve motor function in patients with stroke are needed. The objective of this study was to investigate the effect of kinesthetic taping of the anterior thigh and knee on maximal...... walking speed and clinical indices of spasticity in patients with stroke. METHODS: Thirty-two patients (9 women) receiving rehabilitation after stroke (average, 50 days since stroke) who had impaired walking ability were recruited. Primary outcome was maximal walking speed measured by the 10-meter walk...... test. Secondary outcomes were number of steps taken during the test and clinical signs of spasticity measured by the Tardieu Scale. Tests were conducted before and immediately after application of kinesthetic tape to the anterior thigh and knee of the paretic lower limb. RESULTS: After application...

  10. Kinesiology taping as an adjunct for pain management in cancer?

    Science.gov (United States)

    Banerjee, Gourav; Rebanks, Jonathan; Briggs, Michelle; Johnson, Mark I

    2016-07-14

    We present the case of a 46-year-old woman who developed severe pain described as 'tearing' and 'searing' in the left side of the mid-trapezius region near the thoracic 8 vertebra (T8). The patient had undergone surgery for T8 fracture which had resulted from metastasis (secondary breast cancer). A community nurse referred the patient for physiotherapy assessment and treatment for her musculoskeletal pain and related symptoms that had affected her mobility and functional activities. The patient was treated with soft tissue therapy with the addition of kinesiology taping on follow-up visits. Kinesiology tape was applied over her left side trapezius region and left shoulder. The patient reported significant reductions in pain severity and felt greater control and stability over her left shoulder region, which resulted in better function and overall quality of life measures. She did not report any adverse effects. 2016 BMJ Publishing Group Ltd.

  11. Conventional Tape versus Kinesiotape for Hallux Valgus Correction

    Directory of Open Access Journals (Sweden)

    Nadia Lotfy Radwan

    2017-01-01

    Full Text Available This study was commenced to compare the effect of Kinesiotape (KT versus conventional tape (CT on HVA and IMA as well as the intensity of pain from HV deformity. Methodology: Female patients with age 45 to 60 years and diagnosed with mild to moderate HV were included in the study. The foot pain intensity was assessed by visual analogue scale (VAS before applying tape and after completion of the study. Results: The outcome measures of pain intensity showed a non-significant difference between both groups before intervention (p>0.05. Within both KT and CT groups, the pre-and post-treatment scores were significantly different (p˂0.05. In the comparison of the post treatment scores, there was a significant difference (p˂0.05 between both groups favouring the KT group..

  12. Kinesio taping effect on biceps brachii muscle strength

    OpenAIRE

    Králová Dagmar; Novotný Jan; Řezaninová Jana

    2013-01-01

    This work aimed at presenting the idea of inventor Dr. Kenzo Kase that kinesio tape application with proximal base leads to muscle contraction facilitation and application with distal base leads to muscle contraction inhibition. Twenty male volleyball players with the dominant shoulder girdle muscle imbalance between the ages of 25 and 30 participated in this study. There were compared two techniques which were placed on biceps brachii muscle in shoulder and elbow joint extension. Isokinetic ...

  13. "The Political Business Cycle: New Evidence from the Nixon Tapes"

    OpenAIRE

    Burton A. Abrams; James L. Butkiewicz

    2011-01-01

    Drawing from the personal tape recordings made during the presidency of Richard Nixon, we uncover and report in this paper new evidence that Nixon manipulated Arthur Burns and the Federal Reserve Bank into creating a political business cycle that helped secure Nixon’s reelection victory in 1972. Nixon understood the risks that his desired monetary policy imposed, but chose to trade longer-term economic costs to the economy for his own short-term political benefit.

  14. NdFeB thick films prepared by tape casting

    International Nuclear Information System (INIS)

    Pawlowski, B.; Schwarzer, S.; Rahmig, A.; Toepfer, J.

    2003-01-01

    NdFeB films of thickness between 100 and 800 μm were prepared by tape casting of a slurry containing 84-95 wt% of commercial NdFeB powder (MQP-B, -Q and -S). After curing the flexible green tapes at 120 deg. C non-porous magnetic films are obtained. The remanence of the films is in the range of 350-450 mT and the coercivity is between 300 and 800 kA/m depending on the type of MQP powder used. The magnetic properties of the films are discussed in relation to film composition and type of magnetic material. For MEMS applications the thick films are magnetized with a multi-pole stripe pattern with 1 mm pole pitch. The induction at the surface of the films was measured with a Hall probe and compared to theoretical calculations. The results indicate that the films are completely magnetized regardless of the film thickness. Tape-casted NdFeB thick films are promising candidates for applications in micro-systems or actuators. Miniaturization of the magnet components is one of the key issues in the development of electromagnetic micro-systems, thus creating a need for replacement of small sintered magnets by magnetic thick film components. Other applications include encoders

  15. Jitter analysis utilizing a high speed FM tape recorder.

    Science.gov (United States)

    Nazliel, B; Kuruoğlu, R

    2000-09-01

    Jitter analysis in single fiber EMG (SFEMG) is usually done on-line during recording. However, this technique frequently prolongs the study and makes re-analysis impossible. We attempted to measure jitter with a high speed FM tape recorder and compare the results with the previously published values. SFEMG data, acquired with voluntary activation on extensor digitorum communis muscle of 25 healthy relatives of children with myasthenia gravis were retrospectively analyzed. Fiber density (FD) was estimated on-line. Five to 18 single fiber action potential (SFAP) pairs were studied in each subject. The wow of the tape recorder was 6 microseconds. Mean (SD) (upper 95th percentile) FD, individual jitter, highest jitter, mean jitter and interspike interval were 1.60 (0.18) (1.90), 25.30 (11.20) (57.00) microseconds, 31.24 (6.87) (47.00) microseconds, 25.08 (5.04) (43.00) microseconds, and 0.67 (0.11) (0.91) ms respectively. Mean jitter in the pooled SFAP pairs and mean MCD were found to be lower than the published values of the Ad Hoc Committee of the AAEM Special Interest Group on Single Fiber EMG. A high speed FM tape recorder can be reliably used for the off-line analysis of jitter.

  16. Low back pain during pregnancy and Kinesio tape application.

    Science.gov (United States)

    Reyhan, Aycan Çakmak; Dereli, Elif Elçin; Çolak, Tuğba Kuru

    2017-01-01

    Low back pain is a common problem during pregnancy. Although the pain usually occurs in the third trimester, it might be seen in the first trimester, too. There are various types of applications for the treatment of low back pain during pregnancy. However, there is a lack of evidence for the effectiveness of each method. If there is not an obvious deficit, bed rest, exercise, conventional physiotherapy, using protective principles for the lumbar area are recommended, since the main and the only complaint is low back pain. It is aimed in the current review to investigate the use of Kinesio tape in the low back pain seen during pregnancy and to review the literature related to this subject. There are only a few studies investigating the effect of Kinesio tape during pregnancy in the literature and they mostly did not aim to study the low back pain, further evidence and studies are needed to investigate the use of Kinesio tape for the low back pain seen during pregnancy as there is not evidence strong enough. Kinesiotape application aims to increase circulation and mobility, and regarding these gains decreased pain and increased performance are expected.

  17. Simulation of YBCO Tape and Coils in HTS Maglev System

    Directory of Open Access Journals (Sweden)

    Song Mengxiao

    2017-01-01

    Full Text Available In the process of running high temperature superconducting maglev train, the AC(Alternating Current loss of superconducting coil is directly related to its safe operation and operating cost. In this paper, the simulation model was built based on the finite element software COMSOL Multiphysics, and mainly simulated and calculated the AC losses of YBCO(Yttrium Barium Copper Oxide tape and coils. In this model, as the solving object, the singular and infinite long YBCO tape and coils model was solved with H-formulation and the nonlinear characteristic (E-J constitutive law and anisotrophy (B-J characteristic were taken into consideration as the theoretical foundation. Then on the basis of the model under maglev suspension system, AC losses under different amplitude and frequence AC currents were calculated. The results shows that under different frequencies and dynamic components, the local maximum AC loss of YBCO tape and coils occurs when the steady-state DC(Direct Current current is 30A. Then comparing with old maglev suspension system, the new system can greatly reduce the energy consumption and the material cost.

  18. Malignant mesothelioma due to asbestos exposure in dental tape.

    Science.gov (United States)

    Markowitz, Steven B; Moline, Jacqueline M

    2017-05-01

    Although most cases of malignant mesothelioma of the pleura are caused by one or more readily recognized sources of exposure to asbestos, cases of the disease with more occult exposure occur, especially since asbestos has been used in over 3,000 products. Dental lining tape contained asbestos from the 1930s until at least the 1970s and was used in the lost wax method of casting crowns, bridges, and other metal dental prosthetic devices. We report six cases of pathology-verified malignant mesothelioma, mostly among dentists, following exposure to airborne dust from asbestos dental tape, which resulted in asbestos tort litigation. According to evidence available at present, chrysotile asbestos was the type of asbestos used in dental tape in the past in the United States, and the described cases followed relatively brief and intermittent exposure to this type of asbestos. These cases underscore the need for comprehensive exposure histories to determine exposure scenarios. Am. J. Ind. Med. 60:437-442, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. 77 FR 13263 - Foreign-Trade Zone 109 - Watertown, NY; Amendment to Application; North American Tapes, LLC...

    Science.gov (United States)

    2012-03-06

    ... used to produce pressure-sensitive adhesive athletic tape with textile fabric backing material for the... American Tapes, LLC (Textile Athletic Tape), Watertown, NY A request has been submitted to the Foreign... of FTZ 109, to amend its application requesting authority on behalf of North American Tapes (NAT), to...

  20. Attaining 2D Black Phosphorus and Investigations into Floating-Electrode Dielectric Barrier Discharge Treatment of Solutions

    Science.gov (United States)

    Smith, Joshua Benjamin

    Since the discovery and isolation of the 2D carbon allotrope, graphene, research into additional 2D materials has significantly expanded. Electrical components continue to decrease in size so there is an ever-growing need for smaller circuitry to keep up with the demand. Research with graphene and additional 2D layered materials, such as transition metal dichalcogenides, brought about a realization of many unique properties that have never been previously explored for applications in electronics, photonics, and optoelectronics. Phosphorene, a novel 2D material isolated from bulk black phosphorus, is an intrinsic p-type material with a variable band gap for a variety of applications. However, these applications are limited by the inability to isolate films of phosphorene. This work investigates some of the previously found techniques for use with graphene isolation and their adaptations to phosphorene. Isolation of phosphorene from black phosphorus was investigated by exfoliation from bulk, chemical vapor deposition, and thin film conversion. Mechanical exfoliation with a tape method, drawing method, and tape/drawing method were used to isolate few-layer black phosphorus samples from bulk material. These methods were also briefly compared to liquid exfoliation of black phosphorus. A chemical vapor deposition approach led to the discovery of a novel method for growth of amorphous red phosphorus thin films from bulk red phosphorus/black phosphorus. An in situ chemical vapor deposition type approach was developed using these thin films for growth of a variety of 2D phosphorus allotropes. Successful conversion has provided fibrous phosphorus wires and hexagons, along with violet phosphorus and eventually black phosphorus. This approach demonstrates progress towards direct growth of 2D black phosphorus onto substrates with average areas >3 microm2 and thicknesses representing samples around 4 layers. Thicker samples were also observed with average areas >100 microm2. X

  1. Tape measuring system using linear encoder and digital camera

    Science.gov (United States)

    Eom, Tae Bong; Jeong, Don Young; Kim, Myung Soon; Kim, Jae Wan; Kim, Jong Ahn

    2013-04-01

    We have designed and constructed the calibration system of line standards such as tape and rule for the secondary calibration laboratories. The system consists of the main body with linear stage and linear encoder, the optical microscope with digital camera, and the computer. The base of the system is a aluminum profile with 2.9 m length, 0.09 m height and 0.18 m width. The linear stage and the linear encoder are fixed on the aluminum profile. The micro-stage driven by micrometer is fixed on the carriage of the long linear stage, and the optical microscope with digital camera and the tablet PC are on the this stage. The linear encoder counts the moving distance of the linear stage with resolution of 1 μm and its counting value is transferred to the tablet PC. The image of the scale mark of the tape is captured by the CCD camera of optical microscope and transferred to the PC through USB interface. The computer automatically determines the center of the scale mark by image processing technique and at the same time reads the moving distance of the linear stage. As a result, the computer can calculate the interval between the scale marks of the tape. In order to achieve the high accuracy, the linear encoder should be calibrated using the laser interferometer or the rigid steel rule. This calibration data of the linear encoder is stored at the computer and the computer corrects the reading value of the linear encoder. In order to determine the center of the scale mark, we use three different algorithms. First, the image profile over specified threshold level is fitted in even order polynomial and the axis of the polynomial is used as the center of the line. Second, the left side and right side areas at the center of the image profile are calculated so that two areas are same. Third, the left and right edges of the image profile are determined at every intensity level of the image and the center of the graduation is calculated as an average of the centers of the left

  2. Do stringy corrections stabilize colored black holes?

    International Nuclear Information System (INIS)

    Kanti, P.; Winstanley, E.

    2000-01-01

    We consider hairy black hole solutions of Einstein-Yang-Mills-dilaton theory, coupled to a Gauss-Bonnet curvature term, and we study their stability under small, spacetime-dependent perturbations. We demonstrate that stringy corrections do not remove the sphaleronic instabilities of colored black holes with the number of unstable modes being equal to the number of nodes of the background gauge function. In the gravitational sector and in the limit of an infinitely large horizon, colored black holes are also found to be unstable. Similar behavior is exhibited by magnetically charged black holes while the bulk of neutral black holes are proved to be stable under small, gauge-dependent perturbations. Finally, electrically charged black holes are found to be characterized only by the existence of a gravitational sector of perturbations. As in the case of neutral black holes, we demonstrate that for the bulk of electrically charged black holes no unstable modes arise in this sector. (c) 2000 The American Physical Society

  3. Study of tape casting of Yttria stabilized zirconia for apply in solid oxide fuel cell

    International Nuclear Information System (INIS)

    Santana, Leonardo de Paulo

    2008-01-01

    The hydrogen economy has been risen as new option for supply the growing global demand for energy. A fuel cell is an electrochemical device able to use hydrogen as a energy source. Carbon dioxide (CO 2 ) emission is very low so it is ecologically friendly, once energy is produced by a reaction of hydrogen and oxygen. The production of energy from hydrogen fuelled devices can be done even in small unities and in a distributed way. It can bring energy for isolated communities, where traditional energy distribution systems can not be reached. A fuel cell is composed essentially of 3 components: anode, cathode and the electrolyte. In present days, there are many materials proposed for use as electrolyte in fuel cells. Among then, Yttria stabilized zirconia (YSZ) is the most studied and effectively used in solid oxide fuel cell. Tape casting technology is a cheap, simple and efficient way to cast ceramics slurries in laminates thick enough to be used as components for fuel cells. Considering theses aspects, in this work, ceramic thin film forming was studied using tape casting technology with raw materials prepared from Brazilian zircon ores. It is described in literature that ceramic slurries are generally made from powders with low surface area (often between 0,5 to 10m 2 /g), and the powders used in this study had larger surface area (often between 40 to 80m 2 /g). The use of zeta potential is indicated to study the stability of a suspension of ceramic powders. However, for suspensions with large concentration of solid, it is also necessary to determine the flow curve, because in these conditions, the double electric layer formed during the stabilization of suspensions can be compressed. In the rheological properties study, calcined ceramic powders were classified using a set of ABNT series screens and separated and retained by the de mesh 60 screen. Flow curve of suspension was determined in aqueous suspensions of these powders. For tape casting processing, a binder

  4. Black holes

    International Nuclear Information System (INIS)

    Carter, B.

    1980-01-01

    In years 1920 as a result of quantum mechanics principles governing the structure of ordinary matter, a sudden importance for a problem raised a long time ago by Laplace: what happens when a massive body becomes so dense that even light cannot escape from its gravitational field. It is difficult to conceive how could be avoided in the actual universe the accumulation of important masses of cold matter having been submitted to gravitational breaking down followed by the formation of what is called to day a black hole [fr

  5. Recording and wear characteristics of 4 and 8 mm helical scan tapes

    Science.gov (United States)

    Peter, Klaus J.; Speliotis, Dennis E.

    1993-01-01

    Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

  6. AC loss in stacks of Bi-2223/Ag tapes modified with ferromagnetic covers at the edges

    Energy Technology Data Exchange (ETDEWEB)

    Safran, S; Goemoery, F [Institute of Electrical Engineering, Slovak Academy of Sciences, Dubravska cesta 9, 842 39 Bratislava (Slovakia); Gencer, Ali [Physics Department, Faculty of Sciences, Ankara University, Tandogan, 06100 Ankara (Turkey)

    2010-10-15

    We investigated the magnetization loss of stacked Bi-2223/Ag tapes with a ferromagnetic cover on the edges. Such modification has been found recently to reduce the AC loss of a single tape; however, the behavior in a coil winding could be different. With experiments and numerical calculations we show that a ferromagnetic cover on the edges of a superconducting tape could reduce its magnetization loss also when the tapes are arranged in a stack. The effect is weaker for larger numbers of tapes but nevertheless remained significant in a stack of four tapes, which was the maximum number studied here. The effects observed experimentally are nicely explained by the results of numerical calculations.

  7. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Zhao, Yong [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Superconductivity Research Group, School of Materials Science and Engineering, University of New South Wale, Sydney 2052, NSW (Australia)

    2015-12-15

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  8. Duality invariance of black hole creation rates

    International Nuclear Information System (INIS)

    Brown, J.D.

    1997-01-01

    Pair creation of electrically charged black holes and its dual process, pair creation of magnetically charged black holes, are considered. It is shown that the creation rates are equal provided the boundary conditions for the two processes are dual to one another. This conclusion follows from a careful analysis of boundary terms and boundary conditions for the Maxwell action. copyright 1997 The American Physical Society

  9. Black holes: the membrane paradigm

    International Nuclear Information System (INIS)

    Thorne, K.S.; Price, R.H.; Macdonald, D.A.

    1986-01-01

    The physics of black holes is explored in terms of a membrane paradigm which treats the event horizon as a two-dimensional membrane embedded in three-dimensional space. A 3+1 formalism is used to split Schwarzschild space-time and the laws of physics outside a nonrotating hole, which permits treatment of the atmosphere in terms of the physical properties of thin slices. The model is applied to perturbed slowly or rapidly rotating and nonrotating holes, and to quantify the electric and magnetic fields and eddy currents passing through a membrane surface which represents a stretched horizon. Features of tidal gravitational fields in the vicinity of the horizon, quasars and active galalctic nuclei, the alignment of jets perpendicular to accretion disks, and the effects of black holes at the center of ellipsoidal star clusters are investigated. Attention is also given to a black hole in a binary system and the interactions of black holes with matter that is either near or very far from the event horizon. Finally, a statistical mechanics treatment is used to derive a second law of thermodynamics for a perfectly thermal atmosphere of a black hole

  10. The air gap between tape and drum in a video recorder

    OpenAIRE

    Moes, H.

    1991-01-01

    Lubrication with ambient air is not quite generally applied. The best known application is the "oil bearing" in tape recording systems for audio, video and computer applications; where the gap height that is needed for effective lubrication may quite easily be attained. This air gap reduces tape friction and wear of tape and recording head substantially. On the other hand, though, the air gap for effective magnetic recording is very small. These conflicting demands on the lubrication conditio...

  11. STU black holes and string triality

    International Nuclear Information System (INIS)

    Behrndt, K.; Kallosh, R.; Rahmfeld, J.; Shmakova, M.; Wong, W.K.

    1996-01-01

    We find double-extreme black holes associated with the special geometry of the Calabi-Yau moduli space with the prepotential F=STU. The area formula is STU-moduli independent and has [SL(2,Z)] 3 symmetry in space of charges. The dual version of this theory without a prepotential treats the dilaton S asymmetric vs T,U moduli. We display the dual relation between new (STU) black holes and stringy (S|TU) black holes using a particular Sp(8,Z) transformation. The area formula of one theory equals that of the dual theory when expressed in terms of dual charges. We analyze the relation between (STU) black holes to string triality of black holes: (S|TU), (T|US), (U|ST) solutions. In the democratic STU-symmetric version we find that all three S, T, and U duality symmetries are nonperturbative and mix electric and magnetic charges. copyright 1996 The American Physical Society

  12. Plasma horizons of a charged black hole

    International Nuclear Information System (INIS)

    Hanni, R.S.

    1977-01-01

    The most promising way of detecting black holes seems to be through electromagnetic radiation emitted by nearby charged particles. The nature of this radiation depends strongly on the local electromagnetic field, which varies with the charge of the black hole. It has often been purported that a black hole with significant charge will not be observed, because, the dominance of the Coulomb interaction forces its neutralization through selective accretion. This paper shows that it is possible to balance the electric attraction of particles whose charge is opposite that of the black hole with magnetic forces and (assuming an axisymmetric, stationary solution) covariantly define the regions in which this is possible. A Kerr-Newman hole in an asymptotically uniform magnetic field and a current ring centered about a Reissner-Nordstroem hole are used as examples, because of their relevance to processes through which black holes may be observed. (Auth.)

  13. STU Black Holes and String Triality

    Energy Technology Data Exchange (ETDEWEB)

    Shmakova, Marina

    2003-05-23

    We found double-extreme black holes associated with the special geometry of the Calabi-Yau moduli space with the prepotential F = STU. The area formula is STU-moduli independent and has [SL(2, Z)]{sup 3} symmetry in space of charges. The dual version of this theory without prepotential treats the dilaton S asymmetric versus T,U-moduli. We display the dual relation between new (STU) black holes and stringy (S|TU) black holes using particular Sp(8,Z) transformation. The area formula of one theory equals the area formula of the dual theory when expressed in terms of dual charges. We analyze the relation between (STU) black holes to string triality of black holes: (S|TU), (T|US), (U|ST) solutions. In democratic STU-symmetric version we find that all three S and T and U duality symmetries are non-perturbative and mix electric and magnetic charges.

  14. Electricity: From Tabletop to Power Plant

    Science.gov (United States)

    Moran, Timothy

    2009-01-01

    While electricity is central to our daily lives, it remains "black box" technology to most students. They know that electricity is produced somewhere and that it costs money, but they do not have personal experience with the operation and scale of the machines that provide it. Fortunately, electricity generation can be added to the more basic…

  15. Towards the theory of mini black holes with subplanckian mass

    International Nuclear Information System (INIS)

    Zeldovich, Y.B.

    1984-01-01

    This chapter phenomenologically examines the question of the decay (evaporation) and formation of mini black holes. Neutral black holes are considered, having neither electrical charge, nor color and weak charge, so that no long range vector field is present beyond gravitational radius. Topics considered include thermodynamic equilibrium and the formation of light black holes, the formation and decay of light black holes in the big bang, and the difficulties of the theory. It is emphasized that the existence of mini black holes has not yet been proven

  16. Quantum black holes: the event horizon as a fuzzy sphere

    International Nuclear Information System (INIS)

    Dolan, Brian P.

    2005-01-01

    Modeling the event horizon of a black hole by a fuzzy sphere leads us to modify some suggestions in the literature concerning black hole mass spectra. We derive a formula for the mass spectrum of quantum black holes in terms of four integers which define the area, angular momentum, electric and magnetic charge of the black hole. Although the event horizon becomes a commutative sphere in the classical limit a vestige of the quantum theory still persists in that the event horizon stereographically projects onto the non-commutative plane. We also suggest how the classical bounds on extremal black holes might be modified in the quantum theory. (author)

  17. The Thermodynamic Efficiency in Static and Dynamic Black Holes

    Science.gov (United States)

    Jafarzade, Kh.; Sadeghi, J.

    2017-11-01

    We note that, in extended phase space the cosmological constant is a thermodynamic variable. In this paper, this cosmological constant lead us to consider a black hole as a heat engine. So, here we take advantage from holographic heat engine and study two kind of different black holes. We first investigate a static black hole (Dyonic BH) and consider the necessary condition to have high efficiency. Also we continue our investigation for dynamic black hole (rotating charged black hole) and study the effect of rotating parameter on the thermodynamic efficiency of holographic heat engine. We show that the rotating parameter has a more effective role than electric charge in thermodynamic efficiency.

  18. Patient goals after tension free vaginal tape operation

    DEFF Research Database (Denmark)

    Glavind, Karin; Bjørk, Jonna; Kousgaard, Sabrina Just

    INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology...... negative emotional reactions during intercourse, less coital incontinence, and less fear of being incontinent during intercourse after the TVT operation. CONCLUSION: This study shows that a woman's sex life does not deteriorate after a TVT operation, that their sexual function improves somewhat...

  19. A comparison of rotary- and stationary-head tape recorders

    Science.gov (United States)

    Watkinson, John R.

    1994-01-01

    Digital recording may take advantage of many types of media, but usually a preferred type of drive or transport emerges for each. In magnetic tape recording, two approaches have emerged in which essentially the same medium is tracked in two radically different ways. This paper compares the characteristics of Rotary- and Stationary-Head transports in an attempt to establish which approach might be considered for a given application. The conclusion is that in many cases there is no obvious choice based on recording physics and that often the choice will be made on the experimental knowledge of the designer.

  20. Exploring the effects of tape-recording on personality assessment.

    Science.gov (United States)

    Lichton, A I; Waehler, C A

    1999-06-01

    This study examined the possible influence of audio and video recording of personality assessment measures on anxiety. Undergraduate students in psychology were randomly assigned to Audiotape, Videotape, or Control conditions and given the State-Trait Anxiety Inventory and Rorschach Inkblot Method. A one-way multivariate analysis of variance indicated no significant differences among these conditions on the Spielberger, et al. State-Trait Anxiety Inventory, A-State scale, and five Rorschach measures of situational anxiety. Tape-recording itself did not seem to affect the anxiety indices of these frequently used personality assessments.

  1. Magnetization reversal in an obliquely oriented metal evaporated tape

    International Nuclear Information System (INIS)

    Srinath, S.; Vavassori, P.; Rekveldt, M.Th.; Cook, R.E.; Felcher, G.P.

    2004-01-01

    Magnetization reversal in obliquely oriented metal evaporated videotapes as a function of the tape depth was studied by vector magneto-optic Kerr effect and polarized neutron reflectivity. The magnetization vector was found to rotate coherently out-of-plane by an angle α during the magnetization reversal for a substantial part of the hysteresis cycle. However α differs between the surface-facing and the substrate-facing sides of the film, with the more oxidized surface layer following closely the applied field. Close to M∼0 the film breaks down magnetically into a collage of small domains, reflecting the crystalline microstructure of the material

  2. Occupational exposure to asbestos in the drywall taping process.

    Science.gov (United States)

    Verma, D K; Middleton, C G

    1980-04-01

    Studies of airborne asbestos fiber concentrations associated with various operations of the drywall taping process have been undertaken in the province of Alberta, Canada. The results show that mixing, sanding and sweeping created high levels of airborne asbestos dust. The measured concentrations were frequently in excess of occupational health standards. Sanding in particular was assessed the most hazardous operation. The results are discussed in light of present and proposed Occupational Health Standards, and in terms of its implications for other workers, household contacts, and consumer's risk. Measures to reduce and control the health hazards associated with the process are described.

  3. The statistical evaluation of duct tape end match as physical evidence

    Science.gov (United States)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  4. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    Science.gov (United States)

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  5. Reflective tape applied to bicycle frame and conspicuity enhancement at night

    DEFF Research Database (Denmark)

    Costa, Marco; Bonetti, Leonardo; Belelli, M.

    2016-01-01

    Objective: Four studies were conducted to assess bicyclist conspicuity enhancement at night by the application of reflective tape (ECE/ONU 104) to the bicycle rear frame and to pedal cranks. Background: Previous studies have tested the benefits of reflective markings applied to bicyclist clothing......, detection distance using the reflective markings was 146.47 m. Reflective tape applied to pedal cracks resulted in a detection distance of 168.60 m. Conclusion: Reflective tape applied to the rear bicycle frame can considerably increase bicyclist conspicuity and safety at night. Application: Reflective tape...... is highly recommended to complement anterior and rear lights in bicycle riding at night....

  6. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes

    Science.gov (United States)

    Krämer, D.; Lützenkirchen-Hecht, D.; Lühmann, B.; Keite-Telgenbüscher, K.; Frahm, R.

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  7. Bending strain study of Bi-2223/Ag tapes using Hall sensor magnetometry

    International Nuclear Information System (INIS)

    Lahtinen, M.; Paasi, J.; Sarkaniemi, J.; Han, Z.; Freltoft, T.

    1996-01-01

    The influence of room temperature bending on critical current (I c ) of Bi-2223/Ag tapes is studied by Hall sensor magnetometry, four-point method and scanning electron microscopy. Hall sensor magnetometry allows one to assess tape homogeneity and the amount of mechanical damage caused by bending. The microstructure of the Bi-2223 ceramic is found to strongly affect the tape behavior under bending strain. In a tape with moderate I c = 6.1 A at 77 K and a porous ceramic core, crack propagation took place normal to the Ag-ceramic interface, whereas in tapes with dense core, I c above 10 A at 77 K, cracks propagated in the tape plane. In monofilamentary tapes core homogeneity correlated with good bending strain performance. In multifilamentary tapes crack propagation between filaments was prohibited by the Ag matrix, thus leading to enhanced strain tolerance. In the high I c tapes studied, bending to 25 mm radius resulted in 1%--2% I c degradation

  8. Influence of powder pre-annealing on the phase formation and critical current of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Chen, X.P.; Grivel, Jean-Claude; Li, M.Y.

    2004-01-01

    the precursor with Ca2PbO4 phase (tape T1) had lower transformation rate of 2223 phase than tapes fabricated using the precursor with 3321 phase (tape T2). SEM results show that a large fraction of secondary phases with big particle size was formed in the tape T1 during the subsequent sintering, which might....... The effects of different precursors were investigated by XRD, SEM/EDS and critical current measurements. It has been found that both the microstructure and phase formation depended strongly on the different lead-rich phases, which determined the reactivity of the precursor. Tapes fabricated using...... degrade the critical current of the tapes. On the contrary, a small amount of secondary phases with small particle size was formed in the tape T2. Consequently, the critical current of tape T1 was lower than that of tape T2. (C) 2004 Elsevier B.V. All rights reserved....

  9. Making Blackness, Making Policy

    OpenAIRE

    Geller, Peter

    2012-01-01

    Too often the acknowledgment that race is a social construction ignores exactly how this construction occurs. By illuminating the way in which the category of blackness and black individuals are made, we can better see how race matters in America. Antidiscrimination policy, social science research, and the state's support of its citizens can all be improved by an accurate and concrete definition of blackness. Making Blackness, Making Policy argues that blackness and black people are literally...

  10. Black hole critical phenomena without black holes

    Indian Academy of Sciences (India)

    Black holes; numerical relativity; nonlinear sigma. Abstract. Studying the threshold of black hole formation via numerical evolution has led to the discovery of fascinating nonlinear phenomena. ... Theoretical and Computational Studies Group, Southampton College, Long Island University, Southampton, NY 11968, USA ...

  11. AC loss characteristics of Bi-2223 HTS tapes under bending

    International Nuclear Information System (INIS)

    Kim, Hae-Joon; Kim, J.H.; Cho, J.W.; Sim, K.D.; Kim, S.; Oh, S.S.; Kwag, D.S.; Kim, H.J.; Bae, J.H.; Seong, K.C.

    2006-01-01

    Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motors and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. AC loss is also important consideration for many large-scale superconducting devices. In the fabrication of the devices, the critical current (I c ) of the high temperature superconductor degrades due to many reasons including the tension applied by bending and thermal contraction. These mechanical loads reduce the I c of superconducting wire and the I c degradation affects the AC loss of the wire. The I c degradation and AC loss of Bi-2223 HTS tape were measured under tension and bending conditions at 77 K and self-field. Moreover, the frequency characteristics of AC loss was measured at the 30-480 Hz. As a result, self-field penetrates the deeper into the conductor at the lower frequency, which means higher self-field losses per cycle

  12. STS-108 Mission Highlights Resource Tape. Part 2 of 3

    Science.gov (United States)

    2002-01-01

    This video is a continuation of 'STS-108 Mission Highlights Resource Tape: Part 1 of 3' (Internal ID 2002049331). Flight day four footage continues with a video tour of the International Space Station (ISS). During flight day five, an exterior view of the Multipurpose Logistics Module (MPLM) is seen, followed by the crew unloading the supplies and equipment from the MPLM. Commander Dominic Gorie and Mission Specialist Linda Godwin are seen making preparations for the Extravehicular Activity (EVA) scheduled for the following day. Footage of an exterior view of the ISS is also shown. Flight day six footage includes Godwin and Mission Specialist Daniel Tani suiting up for their EVA and the installation of thermal blankets around the solar array wings of the ISS. Expedition 3 Commander Frank Culbertson is seen working in the ISS laboratory during flight day seven. Views are shown of Saudi Arabia and the Red Sea, the western coast of Australia, Cuba and Florida, and Switzerland and Northern Italy. During flight day eight, the crew is seen stowing objects in the MPLM for return to earth. The video concludes with footage of the treadmill used by the astronauts for physical exercise. Flight days nine through twelve are included in 'STS-108 Mission Highlights Resource Tape: Part 3 of 3' (Internal ID 2002049329).

  13. Self-field AC losses in Bi-2223 superconducting tapes

    International Nuclear Information System (INIS)

    Mueller, K. H.; Leslie, K.E.

    1996-01-01

    Full text: The self-field AC loss in Bi-2223 silver sheathed tapes for AC currents of up to 100 A was measured at 77 K and frequencies of 60 Hz and 600 Hz using a lock-in amplifier. The frequency dependence indicated a purely hysteretic loss which can be well described in terms of the critical state model for a flat superconducting strip. The only parameter needed to predict the self-field AC loss is the critical current of the critical state. Because the loss voltage is extremely small compared with the inductive voltage, a very high accuracy of the lock-in amplifier phase setting is required. Unlike in loss measurements on cylindrical superconducting samples, in the case of the tape the measuring circuit leads have to be brought out from the surface forming a loop where the changing magnetic field induces an additional voltage. Only if the loop formed by the leads at the voltage tabs is large enough will the apparent power dissipation approach the real AC loss associated with the length of the sample probed

  14. Evolving Requirements for Magnetic Tape Data Storage Systems

    Science.gov (United States)

    Gniewek, John J.

    1996-01-01

    Magnetic tape data storage systems have evolved in an environment where the major applications have been back-up/restore, disaster recovery, and long term archive. Coincident with the rapidly improving price-performance of disk storage systems, the prime requirements for tape storage systems have remained: (1) low cost per MB, (2) a data rate balanced to the remaining system components. Little emphasis was given to configuring the technology components to optimize retrieval of the stored data. Emerging new applications such as network attached high speed memory (HSM), and digital libraries, place additional emphasis and requirements on the retrieval of the stored data. It is therefore desirable to consider the system to be defined both by STorage And Retrieval System (STARS) requirements. It is possible to provide comparative performance analysis of different STARS by incorporating parameters related to (1) device characteristics, and (2) application characteristics in combination with queuing theory analysis. Results of these analyses are presented here in the form of response time as a function of system configuration for two different types of devices and for a variety of applications.

  15. Critical currents in uranium-doped BiSCCO-tapes

    CERN Document Server

    Toenies, S

    2000-01-01

    region, H subleft brace gb-p right brace depends on the direction of the applied field, the temperature and also the fluence. The position of this transition field was investigated. Large enhancements of the critical current densities were achieved with this irradiation method. Due to the strong activation of the silver-sheath of the samples, the applications of these tapes may be limited. But we could determine the limiting mechanisms of the critical current density in BiSCCO-tapes for the first time. regions in the (H,T)-plane, where J sub c is limited by pinning. Irradiation improves only the pinning in the grains but not the intergranular currents. Regions, where no enhancement is found, are limited by the intergranular currents. The inter- and intragranular currents were determined quantitatively from SQUID measurements of the remanent magnetic moment. Also the grain sizes were determined by this method. The influence of the irradiation on the structure of the samples depended on the uranium content: in ...

  16. The processing of a practical oxide superconductor wire or tape

    International Nuclear Information System (INIS)

    Blaugher, R.D.

    1991-01-01

    There has been substantial progress in recent months in the realization of attractive current density in bulk oxide superconductors. Silver sheathed Bi oxide wire or tape has been produced in a number of laboratories with impressive current density exceeding 10 4 A/cm 2 at 4.2 K in magnetic fields as high as 30 T. This result easily eclipses the performance of conventional 4.2K conductors such as Nb-Ti and Nb 3 Sn, which presents a promise for using oxide conductors for high field magnets. At 77 K similar success have been achieved for Y-Ba-Cu-O bulk materials following various melt processing procedures with the observation of current density near 10 4 A/cm 2 at useful magnetic fields of 1-4 T. There is some question as to whether any of these materials can be formed in long lengths with sufficient mechanical strength and stability to allow operation at high fields in magnet applications. This paper reviews the current progress in producing oxide superconductor wire or tape and a prognosis as to when a practical oxide conductor is realized

  17. Eccentric Exercise, Kinesiology Tape, and Balance in Healthy Men.

    Science.gov (United States)

    Hosp, Simona; Folie, Ramona; Csapo, Robert; Hasler, Michael; Nachbauer, Werner

    2017-07-01

      Deficits in balance have been identified as a possible risk factor for knee injuries in athletes. Despite a lack of evidence for its effectiveness, kinesiology tape (KT) is widely used to prevent knee injuries.   To investigate the influence of KT at the knee joint on balance ability in healthy men after eccentric exercise.   Crossover study.   University laboratory.   Twelve young men with no history of lower limb injury volunteered for the study (age = 23.3 ± 2.6 years). All participants were students enrolled in a sports science program.   Participants performed the balance test with and without KT at the knee joint on 2 separate days.   The ability to maintain balance was assessed during a single-legged-stance test using a computerized balance-stability test system. The test was performed before and after 30 minutes of downhill walking on a treadmill.   Eccentric exercise resulted in a deterioration of balance ability, which was attenuated by the use of KT. Further analyses revealed that the effectiveness of KT depended on the participant's balance status, with the preventive effect being greater in participants presenting with poorer baseline balance ability.   Applied to the knee joint, KT counteracted the exercise-related deterioration of balance ability observed when no tape was used. Participants presenting with below-average balance ability received more benefit from KT. By preventing exercise-related impairment of balance ability, KT might help to reduce the risk of sport-associated knee injuries.

  18. Classification of OPP adhesive tapes according to pyrogram of adhesives.

    Science.gov (United States)

    Kumooka, Y

    2011-03-20

    Pressure sensitive adhesives (PSAs) of colorless and transparent oriented polypropylene (OPP) adhesive tapes were analyzed by pyrolysis/gas chromatography/mass spectrometry (Py/GC/MS). The PSAs were acrylic and rubber-based PSAs and the tapes were classified according to total ion current (TIC) chromatograms of the PSAs. The main pyrolyzates of the acrylic PSAs were decomposition products of monomers, monomers, dimmers and trimers. Those of the rubber-based PSAs were the monomers of elastomers, and subtle peaks observed were the pyrolyzates of tackifiers and volatile additives in the TIC chromatograms. Small differences were observed among the classifications of the acrylic PSAs by Py/GC/MS, attenuated total reflection Fourier transform infrared (ATR FT-IR) and Matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS). The classification of the rubber-based PSAs by Py/GC/MS and that by ATR FT-IR were the same, and a slight difference was observed between those by Py/GC/MS and MALDI MS. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  19. Black Urine

    Directory of Open Access Journals (Sweden)

    Rahim Vakili

    2016-06-01

    Full Text Available A 2-year-old boy was born at term of healthy, non-consanguineous Iranian parents. His mother attended in the clinic with the history of sometimes discoloration of diapers after passing urine. She noticed that first at the age of one month with intensified in recent months. His Physical examination and growth parameters were normal. His mother denied taking any medication (sorbitol, nitrofurantoin, metronidazole, methocarbamol, sena and methyldopa (5. Qualitative urine examination showed dark black discoloration. By this history, alkaptonuria was the most clinical suspicious. A 24-hour-urine sample was collected and sent for quantitative measurements. The urine sample was highly positive for homogentisic acid and negative for porphyrin metabolites.

  20. Influence of kinesiologic tape on postoperative swelling, pain and trismus after zygomatico-orbital fractures.

    Science.gov (United States)

    Ristow, Oliver; Pautke, Christoph; Victoria Kehl; Koerdt, Steffen; Schwärzler, Katharina; Hahnefeld, Lilian; Hohlweg-Majert, Bettina

    2014-07-01

    Surgical treatment of zygomatico-orbital (ZO) fractures is a common procedure in maxillofacial surgery. Often accompanied by pain, trismus and swelling, postoperative morbidity is a major disadvantage, affecting patients' quality of life. The appliance of kinesiologic tape (KT) improves the blood and lymph flow, removing congestions of lymphatic fluid and haemorrhages. The aim of this study was to find out if the application of kinesiologic tape prevents or improves swelling, pain and trismus after zygomatico-orbital fracture surgery, improving patients' postoperative quality of life. A total of 30 patients were assigned for treatment of zygomatico-orbital fractures and were randomly divided into treatment either with or without kinesiologic tape. Tape was applied directly after surgery and maintained for at least 5 days postoperatively. Facial swelling was quantified using a five-line measurement at six specific time points. Pain and degree of mouth opening was measured. Patient's subjective feeling and satisfaction was queried. The results of this study show that application of kinesiologic tape after zygomatico-orbital surgery significantly reduced the incidence of swelling with an earlier swelling maximum, and decreased the maximum turgidity for more than 60% during the first 2 days after surgery. Although, kinesiologic tape has no significant influence on pain control and trismus, mouth opening increased earlier after operation in the kinesiologic tape group compared to the no-kinesiologic tape group. Furthermore, patients with kinesiologic tape felt significantly lower morbidity than those without kinesiologic tape. Therefore kinesiologic tape is a promising, simple, less traumatic, economical approach, which is free from adverse reaction and improves patients' quality of life. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-03-01

    Full Text Available Questions: Is Kinesio Taping more effective than a sham taping/placebo, no treatment or other interventions in people with musculoskeletal conditions? Is the addition of Kinesio Taping to other interventions more effective than other interventions alone in people with musculoskeletal conditions? Design: Systematic review of randomised trials. Participants: People with musculoskeletal conditions. Intervention: Kinesio Taping was compared with sham taping/placebo, no treatment, exercises, manual therapy and conventional physiotherapy. Outcome measures: Pain intensity, disability, quality of life, return to work, and global impression of recovery. Results: Twelve randomised trials involving 495 participants were included in the review. The effectiveness of the Kinesio Taping was tested in participants with: shoulder pain in two trials; knee pain in three trials; chronic low back pain in two trials; neck pain in three trials; plantar fasciitis in one trial; and multiple musculoskeletal conditions in one trial. The methodological quality of eligible trials was moderate, with a mean of 6.1 points on the 10-point PEDro Scale score. Overall, Kinesio Taping was no better than sham taping/placebo and active comparison groups. In all comparisons where Kinesio Taping was better than an active or a sham control group, the effect sizes were small and probably not clinically significant or the trials were of low quality. Conclusion: This review provides the most updated evidence on the effectiveness of the Kinesio Taping for musculoskeletal conditions. The current evidence does not support the use of this intervention in these clinical populations. PROSPERO registration: CRD42012003436. [Parreira PdCS, Costa LdCM, Hespanhol Junior LC, Lopes AD, Costa LOP (2014 Current evidence does not support the use of Kinesio Taping in clinical practice: a systematic review. Journal of Physiotherapy 60: 31–39

  2. Effects of 3 Different Elastic Therapeutic Taping Methods on the Subacromial Joint Space.

    Science.gov (United States)

    Lyman, Katie J; Gange, Kara N; Hanson, Thomas A; Mellinger, Christopher D

    2017-09-01

    The purpose of this study was to examine the effects of 3 different elastic therapeutic taping methods on the subacromial joint space in healthy adults. Pre-/post-test laboratory study method was used in this study. Forty-eight healthy adults with no prior history of shoulder injury or surgery and no history of dominant shoulder pain in the past 6 months were enrolled in the study. Participants were placed into 3 groups (8 males and 8 females per group) on the basis of a consecutively assigned allocation design. A baseline measurement of the acromiohumeral distance (AHD) was taken by using diagnostic ultrasonography for every participant. On the basis of group assignment, participants were then taped according to the Kinesio Tape (Kinesio Tex Classic Tape) guidelines in one of 3 conditions: (1) taping of the supraspinatus from insertion to origin; (2) taping of the anterior and posterior deltoids from insertion to origin; and (3) a combination of both techniques. After a 5-minute wait period, the AHD was remeasured with the tape intervention in place, with each participant serving as his or her own control. Data analysis showed a statistically significant increase in AHD when using the taping technique over the anterior and posterior deltoids (Condition 2). The subacromial space increased in both males and females when the supraspinatus was taped from insertion to origin (Condition 1), but not at a statistically significant level. Condition 3, in which both taping techniques were used simultaneously, did not show an increase at a statistically significant level. The application of the Kinesio Tape from insertion to muscle origin of the supraspinatus or the anterior and posterior deltoid increased the subacromial joint space. Copyright © 2017. Published by Elsevier Inc.

  3. Soldering of Bi-2223/Ag high temperature superconducting tapes with Sn-Pb-Bi-Ag alloy paste

    Energy Technology Data Exchange (ETDEWEB)

    Guo Wei, E-mail: gwei@tsinghua.edu.c [Department of Mechanical Engineering, Key Laboratory for Advanced Manufacturing by Materials Processing Technology, Tsinghua University, Ministry of Education of PR China, Beijing 100084 (China); School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing 100191 (China); Zou Guisheng; Wu Aiping; Bai Hailin; Ren Jialie [Department of Mechanical Engineering, Key Laboratory for Advanced Manufacturing by Materials Processing Technology, Tsinghua University, Ministry of Education of PR China, Beijing 100084 (China)

    2010-01-15

    Soldered joints of Bi-2223/Ag-sheathed high temperature superconducting multifilamentary tapes were fabricated using 63 wt.%Sn-34 wt.%Pb-1 wt.%Bi-2 wt.%Ag paste. The soldered joints were observed by scanning electron microscope (SEM) and X-ray diffraction (XRD). Moreover, the electrical properties of joints were evaluated by current-voltage curves, and the tensile strengths of the joints were also tested. The results show that the soldered joint consists of Ag sheath - Ag{sub 3}Sn compound layer - PbSn{sub 2} and Ag{sub 3}Sn solder layer - Ag{sub 3}Sn compound layer - Ag sheath. The joints are obeyed with Ohms Law and the magnitude of the joint resistance, which deceases with the increase of the overlap length, can reach the order of 10{sup -8} OMEGA. The tensile strength of the joints with a brittle fracture mode is a little lower than that of the original tapes.

  4. Quench behavior of a no-insulation coil wound with stainless steel cladding REBCO tape at 4.2 K

    Science.gov (United States)

    Kim, Kwanglok; Kim, Kwangmin; Bhattarai, Kabindra R.; Radcliff, Kyle; Jang, Jae Young; Hwang, Young Jin; Lee, SangGap; Yoon, Sangwon; Hahn, Seungyong

    2017-07-01

    A single pancake no-insulation (NI) coil was wound in a hermetic way with REBCO tape having a thin (1-2 μm) cladding layer of stainless steel. With an electric heater embedded at the innermost turn of the coil, heater-induced quench tests were performed under a background field of 15 T in a bath of liquid helium at 4.2 K. Despite the large average contact surface resistance of 1.63 {{m}}{{Ω }} cm2 , > 20 times larger than those of pure NI coils, ‘thermal recovery’ was observed at a coil current density (J e ) below 700 A mm-2 mainly due to the local current sharing. The coil experienced nine consecutive ‘thermal runaway’ quenches at J e of 700-820 A mm-2 (power supply limit), yet no discernible coil degradation or damage was observed. The results demonstrated that the stainless steel cladding REBCO tape may be effective at reducing the charging delay of high field NI REBCO magnets without sacrificing the self-protecting feature.

  5. The effect of rigid taping with tension on mechanical displacement of the skin and change in pain perception.

    Science.gov (United States)

    Chen, Shu-Mei; Lo, Sing Kai; Cook, Jill

    2018-04-01

    To investigate the effect of rigid taping that induces mechanical displacement of the skin on pain perception. Single group experiment design with repeated measures. Twenty-three active healthy volunteers (12 men and 11 women) participated in the study. All participants received three different taping procedures: no tape, taping with tension, and taping without tension. The order of three taping conditions was randomised. Skin displacement was measured during taping with tension. A pressure algometer was used to measure the level of pain perception once before taping, and again after each taping condition, in one testing session. The participants were blind to the values of their pressure pain threshold (PPT) during the experimental period. The mean±SD skin displacement in the condition of taping with tension was 2.58±0.49cm. There were significant differences in PPT between taping with tension and taping without tension (mean difference (mean diff)±standard error (SE) 36.43±4.22kPa, p=0.000) and no tape (mean diff±SE 44.31±3.13kPa, p=0.000). No significant difference in PPT between no tape and taping without tension was found (mean diff±SE 7.88±2.83kPa, p=0.067). Taping with tension increases the threshold of pressure pain perception. Therefore, stretch and compression caused by rigid taping with tension could disturb the nociceptive signal transmission and alter pain perception. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Kinesio Taping Improves Perceptions of Pain and Function of Patients with Knee Osteoarthritis. A Randomized, Controlled Trial.

    Science.gov (United States)

    Rahlf, Anna Lina; Braumann, Klaus-Michael; Zech, Astrid

    2018-02-21

    Although increasingly used for therapeutic treatment only limited evidence exists regarding the effects of kinesio taping on patients with knee osteoarthritis. To determine the effects of kinesio taping on pain, function, gait and neuromuscular control concerning patients with knee osteoarthritis (OA). Randomized sham-controlled trial. University laboratory. 141 Patients (65.1±7.0 years) with a clinical and radiographic diagnosis of knee osteoarthritis. Kinesio tape, sham tape or no tape for 3 consecutive days. Self-reported pain, stiffness and function were measured by the Western Ontario and McMaster Universities Arthritis Index (WOMAC). Further tests included the Balance Error Scoring System (BESS-Test), 10-m Walk Test (10MWT), the maximum voluntary isometric contraction force (MVIC) of the quadriceps femoris and knee active range of motion (active ROM). At baseline, there were no differences in all outcomes between groups except for knee flexion. Significant effects were found for WOMAC pain (tape vs. sham p=0.053; tape vs. control p=0.047), stiffness (tape vs. sham p=0.012; tape vs. control p≤0.001) and physical function (tape vs. sham p=0.034; tape vs. control p=0.004). No interactions were found for balance, muscle strength, walking speed or active ROM. Wearing kinesio tape for three consecutive days had beneficial effects regarding self-reported clinical outcomes of pain, joint stiffness and function. This emphasizes that kinesio taping might be an adequate conservative treatment for the symptoms of knee osteoarthritis.

  7. Electrically Conductive Anodized Aluminum Surfaces

    Science.gov (United States)

    Nguyen, Trung Hung

    2006-01-01

    Anodized aluminum components can be treated to make them sufficiently electrically conductive to suppress discharges of static electricity. The treatment was conceived as a means of preventing static electric discharges on exterior satin-anodized aluminum (SAA) surfaces of spacecraft without adversely affecting the thermal-control/optical properties of the SAA and without need to apply electrically conductive paints, which eventually peel off in the harsh environment of outer space. The treatment can also be used to impart electrical conductivity to anodized housings of computers, medical electronic instruments, telephoneexchange equipment, and other terrestrial electronic equipment vulnerable to electrostatic discharge. The electrical resistivity of a typical anodized aluminum surface layer lies between 10(exp 11) and 10(exp 13) Omega-cm. To suppress electrostatic discharge, it is necessary to reduce the electrical resistivity significantly - preferably to surface becomes covered and the pores in the surface filled with a transparent, electrically conductive metal oxide nanocomposite. Filling the pores with the nanocomposite reduces the transverse electrical resistivity and, in the original intended outer-space application, the exterior covering portion of the nanocomposite would afford the requisite electrical contact with the outer-space plasma. The electrical resistivity of the nanocomposite can be tailored to a value between 10(exp 7) and 10(exp 12) Omega-cm. Unlike electrically conductive paint, the nanocomposite becomes an integral part of the anodized aluminum substrate, without need for adhesive bonding material and without risk of subsequent peeling. The electrodeposition process is compatible with commercial anodizing production lines. At present, the electronics industry uses expensive, exotic, electrostaticdischarge- suppressing finishes: examples include silver impregnated anodized, black electroless nickel, black chrome, and black copper. In

  8. Preparation of magnetic tapes for the transfer of information to/from other computer systems

    International Nuclear Information System (INIS)

    Clark, K.D.; Peterson, M.A.

    1982-06-01

    This report documents the method by which a magnetic tape may be written on the CRNL CYBER 170 Model 175/6600 computer system in order to transfer information (source programs and/or coded data) to other computer systems. It will also enable a user to provide the specifications for an incoming magnetic tape which is to be written on another computer system

  9. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    International Nuclear Information System (INIS)

    Takayasu, Makoto; Chiesa, Luisa

    2015-01-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour. (paper)

  10. Numerical and Experimental Investigation of the Electromechanical Behavior of REBCO Tapes

    Science.gov (United States)

    Allen, N. C.; Chiesa, L.; Takayasu, M.

    2015-12-01

    To fully characterize the electromechanical behavior of a Twisted Stacked-Tape Cable (TSTC) it is important to understand the performance of the individual REBCO tapes under various loading conditions. Numerical modeling and experimentation have been used to investigate the electromechanical characteristics of two commercially available REBCO tapes (SuperPower and SuNAM). Tension and combined tension-torsion experiments on single tapes have been continued, from prior preliminary studies, to characterize their critical current behavior and mechanical strength. Additionally, structural finite element analysis was performed on single tapes under tension and combined tension-torsion to investigate the strain dependence of the critical current. The numerical results were compared to the experimental findings for validation. The SuNAM experimental data matched the numerical model very well while the SuperPower tape experienced degradation at lower stress and strain than predicted in the model. The Superpower tape also displayed greater variability in critical current between different samples as compared with the SuNAM tape.

  11. Analytical investigation in bending characteristic of twisted stacked-tape cable conductor

    Science.gov (United States)

    Takayasu, Makoto; Chiesa, Luisa

    2015-12-01

    An analytical model to evaluate bending strains of a twisted stack-tape cable (TSTC) conductor has been developed. Through a comparison with experimental results obtained for a soldered 32-tape YBCO TSTC conductor, it has been found that a Perfect-Slip Model (PSM) taking into account the slipping between tapes in a stacked-tape cable during bending gives much better estimation of the bending performance compared to a No-Slip Model (NSM). In the PSM case the tapes can slip so that the internal longitudinal axial strain can be released. The longitudinal strains of compression and tension regions along the tape are balanced in one twist-pitch and cancel out evenly in a long cable. Therefore, in a cable the strains due to bending can be minimized. This is an important advantage of a TSTC conductor. The effect of the cable diameter size on the bending strain is also expected to be minor, and all tapes composing a TSTC conductor have the same strain response under bending, therefore the cable critical current can be characterized from a single tape behaviour.

  12. Effects of kinesio taping and hot packs on premenstrual syndrome in females.

    Science.gov (United States)

    Choi, Jung-Hyun

    2017-09-01

    [Purpose] This study aimed to evaluate the effects of taping and hot packs on premenstrual syndrome, in an attempt to generate basic data for physical therapy intervention for premenstrual syndrome. [Subjects and Methods] Thirty-two females in their 20s with premenstrual syndrome were randomly assigned to a taping group (n=10), hot pack group (n=11), and taping with hot pack group (n=11). Premenstrual syndrome was assessed using the Menstrual Distress Questionnaire in each participant prior to intervention and was re-assessed after applying kinesio taping and/or hot pack from 10 days before the estimated date of menstruation until the first day of menstruation. [Results] Data revealed that the taping and taping with hot pack groups showed significantly reduced premenstrual syndrome following intervention. In terms of the differences in the Menstrual Distress Questionnaire total score among the groups, the taping with hot pack and hot pack groups showed a significant difference. [Conclusion] These findings indicate that kinesio taping is an easy, non-drug intervention for female college students with premenstrual syndrome.

  13. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of the...

  14. Red Tape: developing and validating a new job-centered measure

    NARCIS (Netherlands)

    van Loon, Nina; Leisink, P.L.M.; Knies, E.; Brewer, Gene

    2016-01-01

    Red tape studies typically focus on burdensome rules that have negative effects on organizations, as perceived by managers. The one-item general red tape scale is representative of this approach. However, scholars have called for improved measures that address the scale's shortcomings. This article

  15. Microstructure, texture and critical current of Ag-sheathed 2223 multifilament tapes

    DEFF Research Database (Denmark)

    Liu, Y.L.; Wang, W.G.; Poulsen, H.F.

    1999-01-01

    An Ag-sheathed 2223 multifilament tape was produced by the powder-in-tube method. The various parts of the tape were heat treated at different temperatures under reduced oxygen partial pressure. The microstructure and the texture were characterized by synchrotron x-ray diffraction and SEM...

  16. Obliquely sputtered Co/Cr thin film tape for bidirectional recording

    NARCIS (Netherlands)

    Nguyen, L.T.; Lisfi, A.; Lodder, J.C.

    2003-01-01

    We report the growth and properties of a thin film tape, which can be equivalently recorded in both directions. The experimental tape consists of a 20 nm thick Co layer grown on top of a Cr underlayer 120 nm. The two layers were consecutively sputtered at incident angle of 70° at room temperature

  17. The air gap between tape and drum in a video recorder

    NARCIS (Netherlands)

    Moes, H.

    1991-01-01

    Lubrication with ambient air is not quite generally applied. The best known application is the "oil bearing" in tape recording systems for audio, video and computer applications; where the gap height that is needed for effective lubrication may quite easily be attained. This air gap reduces tape

  18. Magnetisation loss of BSCCO/Ag tape in uni-directional and rotating magnetic field

    NARCIS (Netherlands)

    Rabbers, J.J.; van der Meer, O.; Klein Zeggelink, W.F.A.; ten Haken, Bernard; Chevtchenko, O.A.; ten Kate, Herman H.J.

    1999-01-01

    BSCCO/Ag tape superconductors are used in applications like power cables, transformers and motors/generators. In these applications, the superconductor is exposed to an alternating magnetic field that can have different orientations with respect to the tape. In applications like three-phase power

  19. 78 FR 58362 - Consolidated Tape Association; Notice of Filing of the Eighteenth Substantive Amendment to the...

    Science.gov (United States)

    2013-09-23

    ... transactions that are not to be reported for inclusion on the consolidated tape. The Commission is publishing..., Inc., EDGA Exchange, Inc. (``EDGA''), EDGX Exchange, Inc. (``EDGX''), Financial Industry Regulatory... list of transactions that ``are not to be reported for inclusion on the consolidated tape.'' That list...

  20. The clinical efficacy of kinesio tape for shoulder pain: a randomized, double-blinded, clinical trial.

    Science.gov (United States)

    Thelen, Mark D; Dauber, James A; Stoneman, Paul D

    2008-07-01

    Prospective, randomized, double-blinded, clinical trial using a repeated-measures design. To determine the short-term clinical efficacy of Kinesio Tape (KT) when applied to college students with shoulder pain, as compared to a sham tape application. Tape is commonly used as an adjunct for treatment and prevention of musculoskeletal injuries. A majority of tape applications that are reported in the literature involve nonstretch tape. The KT method has gained significant popularity in recent years, but there is a paucity of evidence on its use. Forty-two subjects clinically diagnosed with rotator cuff tendonitis/impingement were randomly assigned to 1 of 2 groups: therapeutic KT group or sham KT group. Subjects wore the tape for 2 consecutive 3-day intervals. Self-reported pain and disability and pain-free active ranges of motion (ROM) were measured at multiple intervals to assess for differences between groups. The therapeutic KT group showed immediate improvement in pain-free shoulder abduction (mean +/- SD increase, 16.9 degrees +/- 23.2 degrees ; P = .005) after tape application. No other differences between groups regarding ROM, pain, or disability scores at any time interval were found. KT may be of some assistance to clinicians in improving pain-free active ROM immediately after tape application for patients with shoulder pain. Utilization of KT for decreasing pain intensity or disability for young patients with suspected shoulder tendonitis/impingement is not supported. Therapy, level 1b-.

  1. Is application of Kinesio tape to treat hyperlordosis more effective on abdominal muscles or hamstrings?

    Directory of Open Access Journals (Sweden)

    Sara Abolahrari Shirazi

    2018-01-01

    Full Text Available Background: Hyperlordosis is defined as an abnormal increase in the lumbar arch of >40°. This study compared two taping techniques include abdominal muscles and hamstrings taping for the treatment of lumbar hyperlordosis. Materials and Methods: The randomized clinical trial was performed in Shiraz, Iran, during June and September 2014. Thirty women aged 20–45 years old with at least 40° lumbar lordosis participated. The women were randomized into two groups (n = 15. Abdominal muscles taping was performed for the first group, whereas the other group underwent hamstrings taping with 30% tension. Lumbar lordosis was measured before, immediately after, and 24 h after taping. The two-way repeated measures analysis of variance was used to compare the two groups for lumbar lordosis angle. Results: No significant differences were detected between the lumbar lordosis angles before and immediately after taping in the two groups (P > 0.05. However, a significant reduction was observed in lordosis angle in the abdominal group and the hamstring group 24 h after taping relative to before intervention (P < 0.01. Conclusion: Taping of the abdominal and hamstring muscles was not effective immediately, whereas it decreased lordosis after 24 h.

  2. Comparison of the mechanical properties of therapeutic elastic tapes used in sports and clinical practice

    NARCIS (Netherlands)

    Matheus, Joao Paulo Chieregato; Zille, Rafael Ribeiro; Gomide Matheus, Liana Barbaresco; Lemos, Thiago Vilela; Carregaro, Rodrigo Luiz; Shimano, Antônio Carlos

    2016-01-01

    Study design Cross-sectional laboratory study. Objective The aim of the present study was to evaluate and compare the mechanical properties of different therapeutic elastic tapes used in sports and clinical practice. Background Therapeutic tapes have been used since around the 1800s. They are

  3. Comparison of the mechanical properties of therapeutic elastic tapes used in sports and clinical practice

    NARCIS (Netherlands)

    Matheus, Joao Paulo Chieregato; Zille, Rafael Ribeiro; Gomide Matheus, Liana Barbaresco; Lemos, Thiago Vilela; Carregaro, Rodrigo Luiz; Shimano, Antônio Carlos

    2017-01-01

    Study design Cross-sectional laboratory study. Objective The aim of the present study was to evaluate and compare the mechanical properties of different therapeutic elastic tapes used in sports and clinical practice. Background Therapeutic tapes have been used since around the 1800s. They are

  4. Is application of Kinesio tape to treat hyperlordosis more effective on abdominal muscles or hamstrings?

    Science.gov (United States)

    Shirazi, Sara Abolahrari; Haghighi, Farzaneh Moslemi; Alavi, Seyedeh Mahshid; Nezhad, Fahimeh Freiydoon; Emami, Farahnaz

    2018-01-01

    Hyperlordosis is defined as an abnormal increase in the lumbar arch of >40°. This study compared two taping techniques include abdominal muscles and hamstrings taping for the treatment of lumbar hyperlordosis. The randomized clinical trial was performed in Shiraz, Iran, during June and September 2014. Thirty women aged 20-45 years old with at least 40° lumbar lordosis participated. The women were randomized into two groups ( n = 15). Abdominal muscles taping was performed for the first group, whereas the other group underwent hamstrings taping with 30% tension. Lumbar lordosis was measured before, immediately after, and 24 h after taping. The two-way repeated measures analysis of variance was used to compare the two groups for lumbar lordosis angle. No significant differences were detected between the lumbar lordosis angles before and immediately after taping in the two groups ( P > 0.05). However, a significant reduction was observed in lordosis angle in the abdominal group and the hamstring group 24 h after taping relative to before intervention ( P < 0.01). Taping of the abdominal and hamstring muscles was not effective immediately, whereas it decreased lordosis after 24 h.

  5. The Effect of Ankle Kinesio Tape on Ankle Muscle Activity During a Drop Landing.

    Science.gov (United States)

    Fayson, Shirleeah D; Needle, Alan R; Kaminski, Thomas W

    2015-11-01

    The use of Kinesio Tape among health care professional has grown recently in efforts to efficiently prevent and treat joint injuries. However, limited evidence exists regarding the efficacy of this technique in enhancing joint stability and neuromuscular control. To determine how Kinesio Tape application to the ankle joint alters forces and muscle activity during a drop-jump maneuver. Single-group pretest- posttest. University laboratory. 22 healthy adults with no previous history of ankle injury. Participants were instrumented with electromyography on the lower-leg muscles as they jumped from a 35-cm platform onto force plates. Test trials were performed without tape (BL), immediately after application of Kinesio Tape to the ankle (KT-I), and after 24 h of continued use (KT-24). Peak ground-reaction forces (GRFs) and time to peak GRF were compared across taping conditions, and the timing and amplitude of muscle activity from the tibialis anterior, peroneus longus, and lateral gastrocnemius were compared across taping conditions. No significant differences in amplitude or timing of GRFs were observed (P > .05). However, muscle activity was observed to decrease from BL to KT-I in the tibialis anterior (P = .027) and from BL to KT-24 in the PL (P = .022). The data suggest that Kinesio Tape decreases muscle activity in the ankle during a drop-jump maneuver, although no changes in GRFs were observed. This is contrary to the proposed mechanisms of Kinesio Tape. Further research might investigate how this affects participants with a history of injury.

  6. Comparison of lifts versus tape measure in determining leg length discrepancy.

    Science.gov (United States)

    Badii, Maziar; Wade, A Nicole; Collins, David R; Nicolaou, Savvakis; Kobza, B Jacek; Kopec, Jacek A

    2014-08-01

    To evaluate the validity (accuracy) and reliability of 2 commonly used clinical methods, 1 indirect (lifts) and 1 direct (tape measure), for assessment of leg length discrepancy (LLD) in comparison to radiograph. Twenty subjects suspected of having LLD participated in this study. Two clinical methods, 1 direct using a tape measure and 1 indirect using lifts, were standardized and carried out by 4 examiners. Difference in height of the femoral heads on standing pelvic radiograph was measured and served as the gold standard. The intraclass correlation coefficient assessing interobserver reliability was 0.737 for lifts and 0.477 for tape measure. The remainder of the analysis is based on the average of the measurements by the 4 examiners. Pearson correlation coefficients were 0.93 for the lifts and 0.75 for the tape measure method. Paired sample t tests showed difference in means of 2 mm (p = 0.051) for lifts and -5 mm (p = 0.007) for tape measure compared with radiograph. Sensitivity and specificity were 55% and 89% for lifts and 45% and 56% for tape measure, respectively, using > 5 mm as the definition for LLD. The wrong leg was identified as being shorter in 1 out of 20 subjects using lifts versus 7 out of 20 using tape measure. The indirect standing method of LLD measurement using lifts had superior validity, interobserver reliability, and specificity in comparison with radiograph over the direct supine method using tape measure. Both clinical methods underestimated LLD compared with radiograph.

  7. Final report: High current capacity high temperature superconducting film based tape for high field magnets

    International Nuclear Information System (INIS)

    Ying Xin

    2000-01-01

    The primary goal of the program was to establish the process parameters for the continuous deposition of high quality, superconducting YBCO films on one meter lengths of buffered RABiTS tape using MOCVD and to characterize the potential utility of the resulting tapes in high field magnet applications

  8. The effect of Kinesio Tape on the sitting posture of learners with ...

    African Journals Online (AJOL)

    The effect of Kinesio Tape on the sitting posture of learners with cerebral palsy. ... posture of learners with cerebral palsy. A. Human, M. D. Tshabalala, M.M. Milton, E. Becker, P.A. Lourens, M.E. Cochrane ... Post-test photographs were taken to determine the immediate effects of Kinesio Tape on sitting postures. Data were ...

  9. Dispersion and rheological studies of Y–PSZ tape casting slurry

    Indian Academy of Sciences (India)

    Optimized tape casting slurry was prepared using PEG 600 and BBP as plasticizers and PVB as the binder. Cyclohexanone was used as the homogenizer. The optimized slurry composition with 58% solid loading exhibited shear-thinning pseudoplastic rheological behaviour. Y–PSZ tapes of ∼ 50 m thickness free from ...

  10. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    Directory of Open Access Journals (Sweden)

    Brendon A. Parsons

    2015-06-01

    Full Text Available In a PTFE tape phase-vanishing reaction (PV-PTFE, a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better describe the process of solvent transport in PV-PTFE bromination reactions. Though PTFE tape has been reported as impermeable to some compounds, such as dimethyl phthalate, solvent adsorption to the tape altered its permeability and allowed diffusion through channels of solvent within the PTFE tape. In this case, the solvent-filled pores of the PTFE tape are chemically more akin to the adsorbed solvent rather than to the PTFE fluorous structure. The solvent uptake effect, which was frequently observed in the course of PV-PTFE reactions, can be related to the surface tension of the solvent and the polarity of the solvent relative to the reagent. The lack of pores in bulk PTFE prevents solvents from altering its permeability and, therefore, bulk PTFE is impermeable to most solvents and reagents. However, bromine, which is soluble in liquid fluorous media, diffused through the bulk PTFE. A better understanding of the PTFE phase barrier will make it possible to further optimize the PV-PTFE reaction design.

  11. Two-dimensional and transient thermal model of the continuous tape laying process

    NARCIS (Netherlands)

    Skandali, M.; Jansen, K.M.B.; Koussios, S.; Sinke, J.; Benedictus, R.

    2015-01-01

    The purpose of this study is to simulate the two-dimensional, transient and continuous heat transfer during the thermoset Automated Tape Laying (ATL) process. The heat transfer analysis is coupled with a cure kinetics model of the thermoset prepreg tapes used for the process. Unlike most studies,

  12. Study on Fabrication of Ni-5 at.%W Tapes for Coated Conductors from Cylinder Ingots

    DEFF Research Database (Denmark)

    Ma, L.; Suo, H. L.; Yue, Zhao

    2015-01-01

    Ni-5 at.%W (Ni5W) tapes with a strong cube texture were fabricated using the RABiTS technique and by starting from cylindrical shaped ingots. In contrast to a conventional cuboid-shaped ingot, a cylinder shaped ingot has no anisotropy along the axial direction and the resulting tape will therefore...

  13. Synergistic reinforcement of highly oriented poly(propylene) tapes by sepiolite nanoclay

    NARCIS (Netherlands)

    Bilotti, E.; Deng, H.; Zhang, R.; Lu, D.; Bras, W.; Fischer, H.R.; Peijs, T.

    2010-01-01

    This paper reports the properties of highly oriented nanocomposite tapes based on isotactic PP and needle-like sepiolite nanoclay, obtained by a solid state drawing process. The intrinsic 1D character of sepiolite allows its exploitation in 1D objects, such as oriented polymer fibres and tapes,

  14. On crystallisation and fracture toughness of poly(phenylene sulphide) under tape placement conditions

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Vanden Poel, G.; Warnet, Laurent; Akkerman, Remko

    2013-01-01

    Fibre reinforced thermoplastic tapes are subjected to high heating and cooling rates during the tape placement process. Such high cooling rates can significantly inhibit the crystallisation of the thermoplastic polymer and thereby affect its mechanical properties, such as strength or toughness. In

  15. An Analysis of Certain Elements of an Audio-Tape Approach to Instruction.

    Science.gov (United States)

    Bell, Ronald Ernest

    This study was designed to determine the association between selected variables and an audio-tape approach to instruction. Fifty sophomore students enrolled in a physical anthropology course at Shoreline Community College (Washington) participated in an experimental instructional program that consisted of thirty-two audio-tapes and three optional…

  16. International round robin test for mechanical properties of REBCO superconductive tapes at room temperature

    NARCIS (Netherlands)

    Osamura, K.; Shin, H.S.; Weiss, K.; Nyilas, A.; Nijhuis, Arend; Yamamoto, K.; Machiya, S.; Nishijima, G.

    2014-01-01

    An international round robin test was promoted to establish a test method for room temperature mechanical properties of commercial REBCO superconductive tapes. Seven laboratories practiced a tensile test under the direction of guideline REBCO13 for four different kinds of REBCO tape. From the stress

  17. Black Silicon Solar Cells with Black Ribbons

    DEFF Research Database (Denmark)

    Davidsen, Rasmus Schmidt; Tang, Peter Torben; Mizushima, Io

    2016-01-01

    We present the combination of mask-less reactive ion etch (RIE) texturing and blackened interconnecting ribbons as a method for obtaining all-black solar panels, while using conventional, front-contacted solar cells. Black silicon made by mask-less reactive ion etching has total, average...... reflectance below 0.5% across a 156x156 mm2 silicon (Si) wafer. Black interconnecting ribbons were realized by oxidizing copper resulting in reflectance below 3% in the visible wavelength range. Screen-printed Si solar cells were realized on 156x156 mm2 black Si substrates with resulting efficiencies...... in the range 15.7-16.3%. The KOH-textured reference cell had an efficiency of 17.9%. The combination of black Si and black interconnecting ribbons may result in aesthetic, all-black panels based on conventional, front-contacted silicon solar cells....

  18. Black Silicon Solar Cells with Black Ribbons

    DEFF Research Database (Denmark)

    Davidsen, Rasmus Schmidt; Tang, Peter Torben; Mizushima, Io

    2016-01-01

    We present the combination of mask-less reactive ion etch (RIE) texturing and blackened interconnecting ribbons as a method for obtaining all-black solar panels, while using conventional, front-contacted solar cells. Black silicon made by mask-less reactive ion etching has total, average...... in the range 15.7-16.3%. The KOH-textured reference cell had an efficiency of 17.9%. The combination of black Si and black interconnecting ribbons may result in aesthetic, all-black panels based on conventional, front-contacted silicon solar cells....... reflectance below 0.5% across a 156x156 mm2 silicon (Si) wafer. Black interconnecting ribbons were realized by oxidizing copper resulting in reflectance below 3% in the visible wavelength range. Screen-printed Si solar cells were realized on 156x156 mm2 black Si substrates with resulting efficiencies...

  19. Hawking Temperature of an Arbitrarily Accelerating Black Hole Wei ...

    Indian Academy of Sciences (India)

    Hawking temperature of an arbitrarily accelerating black hole with electric and magnetic charges are obtained based on the. Klein–Gordon equation with a correct-dimension new tortoise coordinate transformation. Key words. Hawking temperature: black hole: correct-dimension new tortoise coordinate transformation. 1.

  20. Supersymmetric black holes in N = 2 supergravity theory

    International Nuclear Information System (INIS)

    Aichelburg, P.C.

    1982-01-01

    We present an exact, asymptotically flat, stationary solution of the field equations of O(2) extended supergravity theory. This solution has a mass, central electric charge as well as a supercharge and constitutes the first exact, supersymmetric generalization of the black hole geometries. The solution generalizes the extreme Reissner-Nordstroem black holes. (Author)

  1. Thermodynamic Properties and Thermodynamic Geometries of Black p-Branes

    International Nuclear Information System (INIS)

    Yi-Huan Wei; Xiao Cui; Jia-Xin Zhao

    2016-01-01

    The heat capacity and the electric capacitance of the black p-branes (BPB) are generally defined, then they are calculated for some special processes. It is found that the Ruppeiner thermodynamic geometry of BPB is flat. Finally, we give some discussions for the flatness of the Ruppeiner thermodynamic geometry of BPB and some black holes. (paper)

  2. Black holes. Chapter 6

    International Nuclear Information System (INIS)

    Penrose, R.

    1980-01-01

    Conditions for the formation of a black hole are considered, and the properties of black holes. The possibility of Cygnus X-1 as a black hole is discussed. Einstein's theory of general relativity in relation to the formation of black holes is discussed. (U.K.)

  3. Black Eye: First Aid

    Science.gov (United States)

    First aid Black eye Black eye: First aid By Mayo Clinic Staff A black eye is caused by bleeding under the skin around the eye. Most injuries that cause a ... 13, 2018 Original article: http://www.mayoclinic.org/first-aid/first-aid-black-eye/basics/ART-20056675 . Mayo ...

  4. Effects of low-dye taping on plantar pressure pre and post exercise: an exploratory study.

    LENUS (Irish Health Repository)

    Nolan, Damien

    2009-01-01

    BACKGROUND: Low-Dye taping is used for excessive pronation at the subtalar joint of the foot. Previous research has focused on the tape\\'s immediate effect on plantar pressure. Its effectiveness following exercise has not been investigated. Peak plantar pressure distribution provides an indirect representation of subtalar joint kinematics. The objectives of the study were 1) To determine the effects of Low-Dye taping on peak plantar pressure immediately post-application. 2) To determine whether any initial effects are maintained following exercise. METHODS: 12 asymptomatic subjects participated; each being screened for excessive pronation (navicular drop > 10 mm). Plantar pressure data was recorded, using the F-scan, at four intervals during the testing session: un-taped, baseline-taped, post-exercise session 1, and post-exercise session 2. Each exercise session consisted of a 10-minute walk at a normal pace. The foot was divided into 6 regions during data analysis. Repeated-measures analysis of variance (ANOVA) was used to assess regional pressure variations across the four testing conditions. RESULTS: Reduced lateral forefoot peak plantar pressure was the only significant difference immediately post tape application (p = 0.039). This effect was lost after 10 minutes of exercise (p = 0.036). Each exercise session resulted in significantly higher medial forefoot peak pressure compared to un-taped; (p = 0.015) and (p = 0.014) respectively, and baseline-taped; (p = 0.036) and (p = 0.015) respectively. Medial and lateral rearfoot values had also increased after the second session (p = 0.004), following their non-significant reduction at baseline-taped. A trend towards a medial-to-lateral shift in pressure present in the midfoot immediately following tape application was still present after 20 minutes of exercise. CONCLUSION: Low-Dye tape\\'s initial effect of reduced lateral forefoot peak plantar pressure was lost after a 10-minute walk. However, the tape continued

  5. POSTOPERATIVE URINARY RETENTION AND EARLY REPOSITION OF TENSION-FREE VAGINAL TAPE

    Directory of Open Access Journals (Sweden)

    Marijan Lužnik

    2003-12-01

    Full Text Available Background. The purpose of this article is to show a possible method of treatment of postoperative urinary retention after an initial tension-free vaginal tape.Methods. From December 1999 to May 2003 we performed one hundred TVT procedures at our department, among them five women had postoperative urinary retention evaluated with catheterization. Revision and reposition of tension-free vaginal tape were performed if retention of urine was over 100 ml.Results. Urinary retention after an initial tension-free vaginal tape was successfully treated by early reposition of tension-free vaginal tape. This resulted in immediate residualfree voiding and continence, which remained unchanged at 6 week and 3 month follow-up.Conclusions. Postoperative urinary retention may be treated by reposition instead of dissection or elongation of the tension-free vaginal tape.

  6. Effects of kinesio tape to reduce hand edema in acute stroke.

    Science.gov (United States)

    Bell, Alison; Muller, Melissa

    2013-01-01

    The purpose of the study was to evaluate the effi cacy of Kinesio Tape (Kinesio USA, Albequerque, NM) for reducing hand edema in individuals with hemiplegia post stroke. Seventeen individuals who experienced acute stroke were screened for visual signs of edema and were randomly assigned to experimental and control groups. The experimental group received Kinesio Tape that was applied to hand and forearm for 6 days in combination with standard therapy; the control group received standard therapy. Blinded raters assessed edema reduction via circumferential measurements. Application of Kinesio Tape did not result in statistically signifi cant reduction in edema. Large and medium effect sizes were seen for edema reduction at the metacarpophalangeal and wrist joints, respectively, with Kinesio Tape. Further research is warranted to investigate the utility of Kinesio Tape in edema reduction.

  7. Effects of taping and proprioceptive neuromuscular facilitation for stance phase duration of stroke patients.

    Science.gov (United States)

    Sung, Youn-Bum; Lee, Jun-Cheol; Kim, Kyoung

    2017-11-01

    [Purpose] The purpose of this study was to investigate the effects of taping and proprioceptive neuromuscular facilitation in stroke patients. [Subjects and Methods] Thirty patients who were diagnosed with hemiparalysis due to stroke were selected as subjects of study. Experiment group 1 patients had Kinesio taping applied before applying the PNF, while experiment group 2 patients had McConell taping applied before applying the PNF. The control group had only the PNF applied. The dartfish program was used to evaluate the stance phase of stroke patients. [Results] Experiment group 1 and experiment group 2 showed a significantly longer stance phase duration of the affected side than the control group in week 6. [Conclusion] Application of Kinesio taping has a more positive effect on the stance phase duration than McConell taping in the patients with stroke.

  8. Search for black holes

    International Nuclear Information System (INIS)

    Cherepashchuk, Anatolii M

    2003-01-01

    Methods and results of searching for stellar mass black holes in binary systems and for supermassive black holes in galactic nuclei of different types are described. As of now (June 2002), a total of 100 black hole candidates are known. All the necessary conditions Einstein's General Relativity imposes on the observational properties of black holes are satisfied for candidate objects available, thus further assuring the existence of black holes in the Universe. Prospects for obtaining sufficient criteria for reliably distinguishing candidate black holes from real black holes are discussed. (reviews of topical problems)

  9. Evolution of Archival Storage (from Tape to Memory)

    Science.gov (United States)

    Ramapriyan, Hampapuram K.

    2015-01-01

    Over the last three decades, there has been a significant evolution in storage technologies supporting archival of remote sensing data. This section provides a brief survey of how these technologies have evolved. Three main technologies are considered - tape, hard disk and solid state disk. Their historical evolution is traced, summarizing how reductions in cost have helped being able to store larger volumes of data on faster media. The cost per GB of media is only one of the considerations in determining the best approach to archival storage. Active archives generally require faster response to user requests for data than permanent archives. The archive costs have to consider facilities and other capital costs, operations costs, software licenses, utilities costs, etc. For meeting requirements in any organization, typically a mix of technologies is needed.

  10. Generation of ultra-sound during tape peeling

    KAUST Repository

    Marston, Jeremy O.

    2014-03-21

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure "fracture" bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions.

  11. Fabrication of high Tc superconducting tape by solid reaction method

    International Nuclear Information System (INIS)

    Mukai, H.; Shibuta, N.; Hikata, T.; Sato, K.; Nagata, M.; Hitotsuyanagi, H.

    1988-01-01

    Ag sheathed high T c superconducting tapes (wires) of YBA 2 Cu 3 O y and Bi 1.6 Pb 0.4 Sr 2 Ca 2 Cu 3 O y were fabricated by the powder-in-tube method. Improvements of the powder core density and the crystal orientation were achieved by the pressing and rolling. The critical current density Jc of 4,140 A./cm 2 in Y-systems and of 6,930 A/cm 2 in Bi-systems were obtained at 77.3 K in a zero magnetic field. Using these samples, the authors clarify that magnetic dependence of the Jc was largely improved by increasing the Jc at a zero magnetic field. The critical current Jc was uniform within 3% of distribution in a 15 m long wires. A coil made of the rolled wires could generate 64 gauss of the maximum magnetic fields

  12. Adhesive tape exfoliation: Why it works for graphene

    Science.gov (United States)

    Bohr, Jakob

    2015-03-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful. In particular on the nature of the surprisingly small number of repetitive steps that are needed in order to obtain a single-layer slab. Two frameworks for exfoliation are investigated: parallel exfoliation involving repetitive simultaneous cleaving, the other, serial exfoliation, which involves the repetitive cleaving of a single chunk of graphite. For both cases, parallel and serial exfoliation, it is investigated how many generations of cleavages are needed. An approximate model with the probability distribution expressed as a simple closed form is presented and compared with the simulations.

  13. Continuous welding of unidirectional fiber reinforced thermoplastic tape material

    Science.gov (United States)

    Schledjewski, Ralf

    2017-10-01

    Continuous welding techniques like thermoplastic tape placement with in situ consolidation offer several advantages over traditional manufacturing processes like autoclave consolidation, thermoforming, etc. However, still there is a need to solve several important processing issues before it becomes a viable economic process. Intensive process analysis and optimization has been carried out in the past through experimental investigation, model definition and simulation development. Today process simulation is capable to predict resulting consolidation quality. Effects of material imperfections or process parameter variations are well known. But using this knowledge to control the process based on online process monitoring and according adaption of the process parameters is still challenging. Solving inverse problems and using methods for automated code generation allowing fast implementation of algorithms on targets are required. The paper explains the placement technique in general. Process-material-property-relationships and typical material imperfections are described. Furthermore, online monitoring techniques and how to use them for a model based process control system are presented.

  14. Study on alkyd-based electrically conductive coatings

    Energy Technology Data Exchange (ETDEWEB)

    Du Zhiming; Cong Xiaomin; Wang Peng [State Key Lab. of the Prevention and Control of Explosion Disasters, Beijing Inst. of Tech., Beijing, BJ (China)

    2005-07-01

    Carbonaceous fillers have been widely applied in electrically conductive coatings due to their cheaper, steady electrically conductive capability and other excellent performances. Electrically conductive coatings were synthesized by using graphite and carbon black as fillers in the alkyd resin matrices. Influences of various fillers on electrical conductivity of coatings have been investigated in detail. (orig.)

  15. Violent flickering in Black Holes

    Science.gov (United States)

    2008-10-01

    intense energy flows of electrically charged matter in its vicinity. The environment of a black hole is constantly being reshaped by a riotous mêlée of strong and competing forces such as gravity, magnetism and explosive pressure. As a result, light emitted by the hot flows of matter varies in brightness in a muddled and haphazard way. "But the pattern found in this new study possesses a stable structure that stands out amidst an otherwise chaotic variability, and so, it can yield vital clues about the dominant underlying physical processes in action," says team member Andy Fabian. The visible-light emission from the neighbourhoods of black holes was widely thought to be a secondary effect, with a primary X-ray outburst illuminating the surrounding gas that subsequently shone in the visible range. But if this were so, any visible-light variations would lag behind the X-ray variability, and would be much slower to peak and fade away. "The rapid visible-light flickering now discovered immediately rules out this scenario for both systems studied," asserts Gandhi. "Instead the variations in the X-ray and visible light output must have some common origin, and one very close to the black hole itself." Strong magnetic fields represent the best candidate for the dominant physical process. Acting as a reservoir, they can soak up the energy released close to the black hole, storing it until it can be discharged either as hot (multi-million degree) X-ray emitting plasma, or as streams of charged particles travelling at close to the speed of light. The division of energy into these two components can result in the characteristic pattern of X-ray and visible-light variability.

  16. The effect of kinesio tape on the area of knee on locomotor activity in patients after stroke

    OpenAIRE

    Trčálková, Pavla

    2013-01-01

    Title: The effect of kinesio tape on the area of knee on locomotor activity in patients after stroke Abstract: This bachelor thesis is focused on evaluating the effect of kinesio tape on locomotor activity in patients after stroke. The purpose of this thesis is to compare quality of stereotype of the gait of this patients before and after application of kinesio tape on the area of the knee joint. The theoretical part includes detailed information on kinesio tape, its characteristics, its effe...

  17. LANDSAT-D data format control book. Volume 6, appendix G: GSFC HDT-AM inventory tape (GHIT-AM)

    Science.gov (United States)

    1981-01-01

    The data format specifications of the Goddard HDT inventory tapes (GHITS), which accompany shipments of archival digital multispectral scanner image data (HDT-AM tapes), are defined. The GHIT is a nine-track, 1600-BPI tape which conforms to the ANSI standard and serves as an inventory and description of the image data included in the shipment. The archival MSS tapes (HDT-AMs) contain radiometrically corrected but geometrically uncorrected image data plus certain ancillary data necessary to perform the geometric corrections.

  18. Initial data for N black holes

    International Nuclear Information System (INIS)

    York, J.W. Jr.

    1984-01-01

    In the present work I focus attention on the construction of suitably general initial data, with particular attention to some new results that enable consideration of black holes that can possess spin (and electric charge) as well as orbital motion. (orig.)

  19. Color to black-and-white converter

    Science.gov (United States)

    Perry, W. E.

    1977-01-01

    Lanthanum-modified lead zirconate titanate ceramic plate, when sandwiched between pair of conventional light polarizers, forms electrically controlled coverter for television camera. Assembly can be used with camera at remote site to enable camera to transmit color or black and white signal on command.

  20. Energy and phosphorus recovery from black water

    NARCIS (Netherlands)

    Graaff, de M.S.; Temmink, B.G.; Zeeman, G.; Buisman, C.J.N.

    2011-01-01

    Source-separated black water (BW) (toilet water) containing 38% of the organic material and 68% of the phosphorus in the total household waste (water) stream including kitchen waste, is a potential source for energy and phosphorus recovery. The energy recovered, in the form of electricity and heat,

  1. Anisotropy of the critical current in MgB2 tapes made of high energy milled precursor powder

    DEFF Research Database (Denmark)

    Hässler, W.; Kovac, P.; Eisterer, M.

    2010-01-01

    For applications of MgB2 wires or tapes, high critical currents in high magnetic fields are essential. By using tapes in superconducting coils the anisotropic behaviour of the critical current, i.e. the dependence on the direction of the external field in relation to the tape surface, has to be t...

  2. Pediatric Tape: Accuracy and Medication Delivery in the National Park Service

    Directory of Open Access Journals (Sweden)

    Danielle D. Campagne

    2015-10-01

    Full Text Available Introduction: The objective is to evaluate the accuracy of medication dosing and the time to medication administration in the prehospital setting using a novel length-based pediatric emergency resuscitation tape. Methods: This study was a two-period, two-treatment crossover trial using simulated pediatric patients in the prehospital setting. Each participant was presented with two emergent scenarios; participants were randomized to which case they encountered first, and to which case used the National Park Service (NPS emergency medical services (EMS length-based pediatric emergency resuscitation tape. In the control (without tape case, providers used standard methods to determine medication dosing (e.g. asking parents to estimate the patient’s weight; in the intervention (with tape case, they used the NPS EMS length-based pediatric emergency resuscitation tape. Each scenario required dosing two medications (Case 1 [febrile seizure] required midazolam and acetaminophen; Case 2 [anaphylactic reaction] required epinephrine and diphenhydramine. Twenty NPS EMS providers, trained at the Parkmedic/Advanced Emergency Medical Technician level, served as study participants. Results: The only medication errors that occurred were in the control (no tape group (without tape: 5 vs. with tape: 0, p=0.024. Time to determination of medication dose was significantly shorter in the intervention (with tape group than the control (without tape group, for three of the four medications used. In case 1, time to both midazolam and acetaminophen was significantly faster in the intervention (with tape group (midazolam: 8.3 vs. 28.9 seconds, p=0.005; acetaminophen: 28.6 seconds vs. 50.6 seconds, p=0.036. In case 2, time to epinephrine did not differ (23.3 seconds vs. 22.9 seconds, p=0.96, while time to diphenhydramine was significantly shorter in the intervention (with tape group (13 seconds vs. 37.5 seconds, p<0.05. Conclusion: Use of a length-based pediatric emergency

  3. Kinesio taping to generate skin convolutions is not better than sham taping for people with chronic non-specific low back pain: a randomised trial.

    Science.gov (United States)

    Parreira, Patrícia do Carmo Silva; Costa, Lucíola da Cunha Menezes; Takahashi, Ricardo; Hespanhol Junior, Luiz Carlos; Luz Junior, Maurício Antônio da; Silva, Tatiane Mota da; Costa, Leonardo Oliveira Pena

    2014-06-01

    For people with chronic low back pain, does Kinesio Taping, applied according to the treatment manual to create skin convolutions, reduce pain and disability more than a simple application without convolutions? Randomised trial with concealed allocation, intention-to-treat analysis and blinded assessment of some outcomes. 148 participants with chronic non-specific low back pain. Experimental group participants received eight sessions (over four weeks) of Kinesio Taping applied according to the Kinesio Taping Method treatment manual (ie, 10 to 15% tension applied in flexion to create skin convolutions in neutral). Control group participants received eight sessions (over four weeks) of Kinesio Taping with no tension, creating no convolutions. The primary outcome measures were pain intensity and disability after the four-week intervention. Secondary outcomes were pain intensity and disability 12 weeks after randomisation, and global perceived effect at both four and 12 weeks after randomisation. Applying Kinesio Tape to create convolutions in the skin did not significantly change its effect on pain (MD-0.4 points, 95% CI-1.3 to 0.4) or disability (MD-0.3 points, 95% CI-1.9 to 1.3) at four weeks. There was a small difference in favour of the experimental group for the secondary outcome of global perceived effect (MD 1.4 points, 95% CI 0.3 to 2.5) at four weeks. No significant between-group differences were observed for the other secondary outcomes. Kinesio Taping applied with stretch to generate convolutions in the skin was no more effective than simple application of the tape without tension for the outcomes measured. These results challenge the proposed mechanism of action of this therapy. Brazilian Registry of Clinical Trials, RBR-7ggfkv. Copyright © 2014 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  4. Interior structure of rotating black holes. III. Charged black holes

    International Nuclear Information System (INIS)

    Hamilton, Andrew J. S.

    2011-01-01

    This paper extends to the case of charged rotating black holes the conformally stationary, axisymmetric, conformally separable solutions presented for uncharged rotating black holes in a companion paper. In the present paper, the collisionless fluid accreted by the black hole may be charged. The charge of the black hole is determined self-consistently by the charge accretion rate. As in the uncharged case, hyper-relativistic counterstreaming between ingoing and outgoing streams drives inflation at (just above) the inner horizon, followed by collapse. If both ingoing and outgoing streams are charged, then conformal separability holds during early inflation, but fails as inflation develops. If conformal separability is imposed throughout inflation and collapse, then only one of the ingoing and outgoing streams can be charged: the other must be neutral. Conformal separability prescribes a hierarchy of boundary conditions on the ingoing and outgoing streams incident on the inner horizon. The dominant radial boundary conditions require that the incident ingoing and outgoing number densities be uniform with latitude, but the charge per particle must vary with latitude such that the incident charge densities vary in proportion to the radial electric field. The subdominant angular boundary conditions require specific forms of the incident number- and charge-weighted angular motions. If the streams fall freely from outside the horizon, then the prescribed angular conditions can be achieved by the charged stream, but not by the neutral stream. Thus, as in the case of an uncharged black hole, the neutral stream must be considered to be delivered ad hoc to just above the inner horizon.

  5. Brane world black rings

    International Nuclear Information System (INIS)

    Sahay, Anurag; Sengupta, Gautam

    2007-01-01

    Five dimensional neutral rotating black rings are described from a Randall-Sundrum brane world perspective in the bulk black string framework. To this end we consider a rotating black string extension of a five dimensional black ring into the bulk of a six dimensional Randall-Sundrum brane world with a single four brane. The bulk solution intercepts the four brane in a five dimensional black ring with the usual curvature singularity on the brane. The bulk geodesics restricted to the plane of rotation of the black ring are constructed and their projections on the four brane match with the usual black ring geodesics restricted to the same plane. The asymptotic nature of the bulk geodesics are elucidated with reference to a bulk singularity at the AdS horizon. We further discuss the description of a brane world black ring as a limit of a boosted bulk black 2 brane with periodic identification

  6. Quantitative electron microscopy and spectroscopy of MgB2 wires and tapes

    International Nuclear Information System (INIS)

    Birajdar, B; Peranio, N; Eibl, O

    2008-01-01

    In MgB 2 the correlation of microstructure with superconducting properties, in particular the critical current density, requires powerful analytical tools. Critical current densities and electrical resistivities of different MgB 2 superconductors differ by orders of magnitudes and the current limiting mechanisms have not been fully understood. Granularity of MgB 2 is one significant reason for reduced critical current densities and is introduced intrinsically by the anisotropy of B c2 but also extrinsically by the microstructure of the material. B c2 enhancement by doping is another important challenge for chemical analysis and, at present, doping levels are not well controlled on the sub-μm scale. In this paper the quantitative electron microscopy and spectroscopy methods essential for the microstructural analysis of MgB 2 are described. By quantitative electron microscopy and spectroscopy we mean a combined SEM and TEM analysis that covers various length scales from μm to nm. Contamination-free sample preparation, chemical mapping including B, and advanced chemical quantification using x-ray microanalysis were essential elements of the applied methodology. The methodology was applied to in situ and ex situ MgB 2 wires and tapes with and without SiC additives. Quantitative B analysis by EDX spectroscopy was applied quantitatively in the SEM and TEM, which is a major achievement. Although MgB 2 is a binary system, the thermodynamics of phase formation is complex, and the complexity is dramatically increased if additives like SiC are used. The small, sub-μm grain sizes of the matrix and secondary phases require TEM methods. However, granularity on the μm scale was also identified and underlines the importance of the combined SEM and TEM studies. Significant differences in the microstructure were observed for in situ and ex situ samples. This holds particularly if SiC was added and yielded Mg 2 Si for in situ samples annealed at 600-650 deg. C and Mg-Si-O phases

  7. Research and development efforts relative to superconducting materials. Final report. [Nb/sub 3/Sn tapes

    Energy Technology Data Exchange (ETDEWEB)

    Adam, E; Beishcher, P; Marancik, W; Lucariello, R; Young, M

    1976-04-01

    Three processes for the production of low-loss superconducting tapes of Nb/sub 3/Sn were investigated. They are the rolled-bronze process, the electron beam (EB) bronze deposition process, and the high-rate sputtering process. Shortly after the start of the investigation, effort on the last two processes was suspended because the process-development time that would be needed to arrive at a suitable transmission-line tape appeared most likely to be the shortest with the rolled-bronze process. Long lengths of Nb/sub 3/Sn tapes were prepared by the rolled-bronze process from extruded and rolled bronze-clad niobium billets. Tapes were stabilized by removing the bronze layer after reaction and then coating the exposed Nb/sub 3/Sn with high-purity copper by EB evaporation. Several meters of high quality Nb/sub 3/Sn tapes were produced by the rolled-bronze process. Even when the tapes were stabilized with copper, the losses were as low as 1.8 ..mu..W/cm/sup 2/ at 4.2 K and a surface current density of 500 rms A/cm. Despite early curtailment of the effort on the EB bronze-deposition process, short samples of Nb/sub 3/Sn tapes were produced.

  8. Chemistry of cometary meteoroids from video-tape records of meteor spectra

    Science.gov (United States)

    Millman, P. M.

    1982-01-01

    The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

  9. [Artificial bradycardias due to tape-running problems of old long-term ECG records].

    Science.gov (United States)

    Grimm, W; Schmidt, C; Hoffmann, J; Menz, V; Maisch, B

    1998-11-01

    Artificial bradycardias due to tape-running alterations of old long-term ECG recorders were observed with increasing frequency in the last 2 years at our hospital. To document the extent of this problem, 115 consecutive 24-hour long-term ECG recordings of 10 still used tape recorders with an age of 12 +/- 4 years were examined. Analysis of the tapes with a new analysis system revealed artificial bradycardias with rates of 10 to 40/min in 22 of 115 long-term ECG recordings (19%). These artificial bradycardias were observed in 4 out of 10 examined tape recorders (40%). Three of 4 concerned recorders were 14 years old at the time of examination, and one recorder was only 5 years old. Artificial bradycardias were caused by extensive alterations of tape-running speed in all cases. Diagnostic proof of artificial bradycardias due to tape running alterations on long-term ECG are simultaneous with prolonged RR-intervals occurring increases in all ECG times including P-width. PQ-time, QRS-width and QT-duration with otherwise unchanged ECG morphology. To avoid prolonged hospital stays or therapeutic mistakes like unnecessary pacemaker implantation, especially older long-term ECG-tape recorders should be checked regularly and, if necessary, be replaced by new devices.

  10. Pilot study: investigating the effects of Kinesio Taping in an acute pediatric rehabilitation setting.

    Science.gov (United States)

    Yasukawa, Audrey; Patel, Payal; Sisung, Charles

    2006-01-01

    The purpose of this pilot study is to describe the use of the Kinesio Taping method for the upper extremity in enhancing functional motor skills in children admitted into an acute rehabilitation program. Fifteen children (10 females and 5 males; 4 to 16 years of age), who were receiving rehabilitation services at the Rehabilitation Institute of Chicago participated in this study. For 13 of the inpatients, this was the initial rehabilitation following an acquired disability, which included encephalitis, brain tumor, cerebral vascular accident, traumatic brain injury, and spinal cord injury. The Melbourne Assessment of Unilateral Upper Limb Function (Melbourne Assessment) was used to measure upper-limb functional change prior to use of Kinesio Tape, immediately after application of the tape, and 3 days after wearing tape. Children's upper-limb function was compared over the three assessments using analysis of variance. The improvement from pre- to posttaping was statistically significant, F(1, 14) = 18.9; p < .02. These results suggest that Kinesio Tape may be associated with improvement in upper-extremity control and function in the acute pediatric rehabilitation setting. The use of Kinesio Tape as an adjunct to treatment may assist with the goal-focused occupational therapy treatment during the child's inpatient stay. Further study is recommended to test the effectiveness of this method and to determine the lasting effects on motor skills and functional performance once the tape is removed.

  11. Insects did it first: a micropatterned adhesive tape for robotic applications.

    Science.gov (United States)

    Gorb, Stanislav N; Sinha, Mitali; Peressadko, Andrei; Daltorio, Kathryn A; Quinn, Roger D

    2007-12-01

    Based on the structural and experimental studies of more than 300 insect species from different lineages, we have developed and characterized a bioinspired polymer material with the ability of multiple glue-free bonding and debonding. The material surface is covered with a pattern of microstructures, which resembles the geometry of tenent hairs previously described from the feet of flies, beetles, earwigs and other insects. The tape with such a microstructure pattern demonstrates at least two times higher pull-off force per unit apparent contact area compared to the flat polymer. Additionally, the tape is less sensitive to contamination by dust particles than a commercially available pressure-sensitive adhesive tape. Even if the 'insect tape' is contaminated, it can be washed with a soap solution in water, in order to completely recover its adhesive properties. We have successfully applied the tape to the 120 g wall-climbing robot Mini-Whegs. Furthermore, the tape can be used for multiple adhering of objects to glass surfaces or as a protective tape for sensitive glass surfaces of optical quality. Another area of potential applications is gripping and manipulation of objects with smooth surfaces.

  12. Reflective Tape Applied to Bicycle Frame and Conspicuity Enhancement at Night.

    Science.gov (United States)

    Costa, Marco; Bonetti, Leonardo; Bellelli, Manuela; Lantieri, Claudio; Vignali, Valeria; Simone, Andrea

    2017-05-01

    Four studies were conducted to assess bicyclist conspicuity enhancement at night by the application of reflective tape (ECE/ONU 104) to the bicycle rear frame and to pedal cranks. Previous studies have tested the benefits of reflective markings applied to bicyclist clothing. Reflective jackets however need to be available and worn while reflective markings enhance conspicuity without any active behavior by the bicyclist. In the first study, reflective tape was applied to the rear frame. Detection distance was compared in four conditions: control, rear red reflector, high visibility jacket, and reflective tape. In the second study, the same conditions were studied with night street lighting on and off. In the third study, detection and recognition distances were evaluated in rainy conditions. In the fourth study, visibility was assessed with the reflective tape applied to pedal cranks. In the first study, the application of reflective markings resulted in a detection distance of 168.28 m. In the second study, the detection distance with reflective markings was 229.74 m with public street light on and 256.41 m with public street light off. In rainy conditions, detection distance using the reflective markings was 146.47 m. Reflective tape applied to pedal cracks resulted in a detection distance of 168.60 m. Reflective tape applied to the rear bicycle frame can considerably increase bicyclist conspicuity and safety at night. Reflective tape is highly recommended to complement anterior and rear lights in bicycle riding at night.

  13. Does taping in addition to physiotherapy improve the outcomes in subacromial impingement syndrome? A systematic review.

    Science.gov (United States)

    Saracoglu, Ismail; Emuk, Yusuf; Taspinar, Ferruh

    2018-04-01

    Taping is used with or without other interventions for many purposes, especially to manage pain and improve functional activity in patients with shoulder pain. The aim of this review was to determine whether any taping technique in addition to physiotherapy care is more effective than physiotherapy care alone in patients with shoulder impingement syndrome. A systematic search of Cochrane Database of Systematic Review, MEDLINE (EBSCO), Physiotherapy Evidence Database (PEDro), CINAHL (EBSCO), PUBMED, AMED, EMBASE (OVID), The Kinesio Kinesio® Taping Method, Kinesio® Tex Tape UK and International websites ( www.kinesiotaping.co.uk ; www.kinesiotaping.com ) was conducted to June 2015. The outcome measures were pain, disability, range of motion and muscle strength. As data were not suitable for meta-analysis, narrative synthesis were applied. Three randomized controlled trials and one controlled trial (135 patients) were included. The results were conflicting and weak on the effectiveness of taping as an adjunct therapy for improvement of pain, disability, range of motion and muscle strength. Clinical taping in addition to physiotherapy interventions (e.g. exercise, electrotherapy, and manual therapy) might be an optional modality for managing patients with shoulder impingement syndrome, especially for the initial stage of the treatment; however, we need further robust, placebo controlled and consistent studies to prove whether it is more effective than physiotherapy interventions without taping.

  14. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    Science.gov (United States)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  15. Characterizing acrylic pressure-sensitive adhesive tapes favoring diverse biomedical applications

    Science.gov (United States)

    Alhijji, Saleh Mohammed S.

    Strong, self-adhesive acrylic polymer-based tapes have been identified as FDA-approved medical device construction components that might also serve in diverse biological locations as artificial muscles, ligaments, or compressive support discs. After assuring that the tapes themselves were not cytotoxic, they were evaluated as possible low-tension muscle substitutes for eyelids, jaws, and other modest body re-closing needs, and well as for higher-tension applications as artificial ligaments. Self-adhesion of the tapes to representative biomaterials, before and after radio-frequency glow discharge treatment for surface energy modification, illustrated the conditions for maximum attachment strength to nonphysiologic substances. Attachment to bony host parts was challenging but apparently met by the application of acrylic-composite-to-dentin bonding systems that has shown good long-term experience in the mouth. Above all, the compression-relaxation properties of the tape materials were superior and their uses in potential Nucleus Pulposus applications for spinal disc repair were most completely explored. Tests included tape-disc performance longevity, both dry and wet, for over 5000 load-relaxation cycles, with no apparent changes in results for the most dense of the tapes evaluated. Direct abrasion was avoided by insertion of rigid polymeric layers. It is recommended that the compressive loading properties of acrylic tapes be further evaluated for spine repair applications.

  16. Effects of kinesio taping to the quadriceps femoris muscles on functions of elderly women

    Science.gov (United States)

    Kim, Eun Ja; Lee, Kyoung Bo

    2017-01-01

    [Purpose] The purpose of this study is to investigate effects of kinesio taping to the quadriceps femoris on functions of elderly women. [Subjects and Methods] The subjects of this study were 22 elderly women with osteoarthritis, who were divided into two groups of a general exercise group 12 elderly and a kinesiology taping group 12 elderly. Two groups underwent a 30-min exercise for strengthening the lower limb muscles three times per week for four weeks. After the exercise, the kinesiology taping group was treated by the kinesio taping. Kinesio tapes were attached to the quadriceps femoris, three times per week for four weeks. The Korean Western Ontario and McMaster Universities Osteoarthritis Index, sit to standing, and Time up & Go test were used for assessment before and after the intervention. [Results] As a result, the kinesiology taping group showed significant differences in the Korean Western Ontario and McMaster Universities Osteoarthritis Index, sit to standing, and Time up & Go test between pre- and post-intervention, while the general exercise group showed no significant differences in pre- and post-intervention. There was a significant difference in between-group comparison. [Conclusion] The kinesio taping for the quadriceps femoris was effective on improving functions of elderly women with osteoarthritis. PMID:28744048

  17. Ankle taping can reduce external ankle joint moments during drop landings on a tilted surface.

    Science.gov (United States)

    Sato, Nahoko; Nunome, Hiroyuki; Hopper, Luke S; Ikegami, Yasuo

    2017-09-20

    Ankle taping is commonly used to prevent ankle sprains. However, kinematic assessments investigating the biomechanical effects of ankle taping have provided inconclusive results. This study aimed to determine the effect of ankle taping on the external ankle joint moments during a drop landing on a tilted surface at 25°. Twenty-five participants performed landings on a tilted force platform that caused ankle inversion with and without ankle taping. Landing kinematics were captured using a motion capture system. External ankle inversion moment, the angular impulse due to the medio-lateral and vertical components of ground reaction force (GRF) and their moment arm lengths about the ankle joint were analysed. The foot plantar inclination relative to the ground was assessed. In the taping condition, the foot plantar inclination and ankle inversion angular impulse were reduced significantly compared to that of the control. The only component of the external inversion moment to change significantly in the taped condition was a shortened medio-lateral GRF moment arm length. It can be assumed that the ankle taping altered the foot plantar inclination relative to the ground, thereby shortening the moment arm of medio-lateral GRF that resulted in the reduced ankle inversion angular impulse.

  18. Influence of TVT properties on outcomes of midurethral sling procedures: high-stiffness versus low-stiffness tape.

    Science.gov (United States)

    Prien-Larsen, Jens Christian; Prien-Larsen, Thomas; Cieslak, Lars; Dessau, Ram B

    2016-07-01

    Although there is clear consensus on the use of monofilament polypropylene tapes for treating stress urinary incontinence (SUI), tapes differ in weight, stiffness, and elasticity. In this study, we compared outcomes of two tape types: high-stiffness Intramesh SOFT L.I.F.T versus low-stiffness Intramesh L.I.F.T. tape. Our null hypothesis was that in terms of performance, SOFT tape equaled L.I.F.T. tape. Six hundred and sixty women underwent prospective transvaginal tape (TVT) surgery for SUI: 210 had the SOFT tape placed and 450 the L.I.F.T. tape. Follow-ups were scheduled at 3 and 12 months. Objective cure at 3-months' follow-up was 87 % in the SOFT group vs 94 % in the L.I.F.T. group (p = 0.003) and at 12 months 86 vs 96 % (p = 0.0004), respectively. Subjective outcomes were equal. For SOFT tape, the objective failure rate at 3 months was especially pronounced in women older than 70 years: 31 vs 10 % (p = 0.008), and subjective failure was 24 vs 7 % (p = 0.01). At 12 months, objective failure for the SOFT tape was significantly higher in both age groups compared with L.I.F.T. [odds ratio (OR) 2.17]. Multivariate analysis showed that body mass index (BMI) ≥30 (OR 2.41), mixed incontinence (MUI) (OR 2.24), use of SOFT tape (OR 2.17), and age ≥ 70 years are significant independent risk factors for surgical failure. Outcomes with SOFT tape are significantly inferior than with L.I.F.T. tape, especially among elderly women. Therefore, the two variants of monofilament polypropylene tape are not interchangeable.

  19. Inefficacy of Kinesio-Taping(®) on early postoperative pain after ACL reconstruction: Prospective comparative study.

    Science.gov (United States)

    Laborie, M; Klouche, S; Herman, S; Gerometta, A; Lefevre, N; Bohu, Y

    2015-12-01

    Kinesio-Taping(®) (K-Tape) is used in sports traumatology with the aim of reducing pain and improving blood and lymph circulation. The main objective of the present study was to assess the efficacy of K-Tape on early postoperative pain after anterior cruciate ligament (ACL) reconstruction. The study hypothesis was that K-Tape significantly decreases pain. A prospective non-randomized comparative study was conducted in 2013-2014 and included all patients who underwent primary ACL reconstruction by hamstring graft. Analgesia was standardized. Two groups, "K-Tape" and "controls", were formed according to the days on which the study physiotherapist was present. The K-Tape compression/decompression assembly was applied immediately postoperatively and maintained for 3days. Patients filled out online questionnaires. The main assessment criterion was mean postoperative pain (D0-D3) on a 0-to-10 scale. Secondary criteria were analgesia intake on the three WHO levels, awakening during the night of D0 due to pain, signs of postoperative discomfort, and patient satisfaction. Sixty patients (30 per group) were included, 57 of whom could be assessed: 28 K-Tape, 29 controls; 44 male, 13 female; mean age, 30.9±8.9 years. At inclusion, the two groups were comparable. There was no significant difference in mean (D0-D3) knee pain intensity: 3.8±2.2 for K-Tape, and 3.9±2 for controls (P=0.93). Analysis of variance (ANOVA) found no significant intergroup difference in evolution of pain (P=0.34). There were no other significant differences on the other assessment criteria. K-Tape showed no efficacy on early postoperative pain following ACL reconstruction. III; prospective non-randomized comparative study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Kinesio Taping to generate skin convolutions is not better than sham taping for people with chronic non-specific low back pain: a randomised trial

    Directory of Open Access Journals (Sweden)

    Patrícia do Carmo Silva Parreira

    2014-06-01

    Full Text Available Question: For people with chronic low back pain, does Kinesio Taping, applied according to the treatment manual to create skin convolutions, reduce pain and disability more than a simple application without convolutions? Design: Randomised trial with concealed allocation, intention-to-treat analysis and blinded assessment of some outcomes. Participants: 148 participants with chronic non-specific low back pain. Intervention: Experimental group participants received eight sessions (over four weeks of Kinesio Taping applied according to the Kinesio Taping Method treatment manual (ie, 10 to 15% tension applied in flexion to create skin convolutions in neutral. Control group participants received eight sessions (over four weeks of Kinesio Taping with no tension, creating no convolutions. Outcome measures: The primary outcome measures were pain intensity and disability after the four-week intervention. Secondary outcomes were pain intensity and disability 12 weeks after randomisation, and global perceived effect at both four and 12 weeks after randomisation. Results: Applying Kinesio Tape to create convolutions in the skin did not significantly change its effect on pain (MD–0.4 points, 95% CI–1.3 to 0.4 or disability (MD–0.3 points, 95% CI–1.9 to 1.3 at four weeks. There was a small difference in favour of the experimental group for the secondary outcome of global perceived effect (MD 1.4 points, 95% CI 0.3 to 2.5 at four weeks. No significant between-group differences were observed for the other secondary outcomes. Conclusion: Kinesio Taping applied with stretch to generate convolutions in the skin was no more effective than simple application of the tape without tension for the outcomes measured. These results challenge the proposed mechanism of action of this therapy. Trial registration: Brazilian Registry of Clinical Trials, RBR-7ggfkv. [Parreira PCS, Costa LCM, Takahashi R, Hespanhol Junior LC, da Luz Junior MA, da Silva TM, Costa LOP

  1. AC Application of HTS Conductors in Highly Dynamic Electric Motors

    International Nuclear Information System (INIS)

    Oswald, B; Best, K-J; Setzer, M; Duffner, E; Soell, M; Gawalek, W; Kovalev, L K

    2006-01-01

    Based on recent investigations we design highly dynamic electric motors up to 400 kW and linear motors up to 120 kN linear force using HTS bulk material and HTS tapes. The introduction of HTS tapes into AC applications in electric motors needs fundamental studies on double pancake coils under transversal magnetic fields. First theoretical and experimental results on AC field distributions in double-pancake-coils and corresponding AC losses will be presented. Based on these results the simulation of the motor performance confirms extremely high power density and efficiency of both types of electric motors. Improved characteristics of rare earth permanent magnets used in our motors at low temperatures give an additional technological benefit

  2. Ultrafiltration performance of tubular membrane modules fitted with turbulent promoter. Twisted tape and static mixer; Ranryu sokushintai wo sobishita kangata gengai roka tokusei. Twist tape to static mixer

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, T.; Kobayashi, H.; Ishikawa, T.; Kamiya, T. [Kogakuin University, Tokyo (Japan); Niitsu, T.; Inoue, H. [Soka University, Tokyo (Japan)

    1996-01-20

    The permeate flux of a membrane module fitted with a twisted tape or static mixer was 4-7.7 times higher than that of a membrane module without any turbulent promoter. Use of a twisted tape or static mixer shortened separation time. The energy consumption per unit mass of permeate due to pressure drop in the membrane module with twisted tape or static mixer was 2-3 times higher than that in the membrane module without turbulent promoter. The permeate flux solved by introducing the value of mass transfer coefficient into the osmotic pressure model coincided well with experimental results, where the mass transfer coefficient was obtained by simulating experimental formula of heat transfer in a pipe fitted with a twisted tape or static mixer into a mass transfer correlation by the heat transfer-mass transfer analogy. The mass transfer coefficient in a membrane module with twisted tape or static mixer increased to about 4 to 8 times that of a membrane module without turbulent promoter. 7 refs., 10 figs.

  3. Formulation and screen printing of water based conductive flake silver pastes onto green ceramic tapes for electronic applications

    International Nuclear Information System (INIS)

    Faddoul, Rita; Reverdy-Bruas, Nadège; Blayo, Anne

    2012-01-01

    Highlights: ► Formulation of water-based pastes. ► Viscosity, yield stress, elastic and viscous modulus determination. ► Screen printing onto green ceramic tapes. ► Rheology effect on line dimensions and electrical properties. ► Resistivity ∼18–33 nΩ m. Minimum width ∼60 μm after sintering. - Abstract: Environmentally friendly, water-based silver pastes, adapted for screen printing, were formulated with different silver contents (67–75%). These pastes allowed screen printing onto low temperature co-fired ceramic (LTCC) of narrow conductive tracks with a 60 μm line width and a 3 × 10 −8 Ω m electrical resistivity. Inks were formulated with a mixture of spherical and flake shape silver particles with 2–4 μm mean diameter. Rheological behaviour of pastes was studied in order to determine its effect on printed lines properties. Prepared inks were then screen printed and sintered under normal atmosphere at 875 °C. As expected, electrical properties depended on silver content. Resistivity values varying from 1.6 × 10 −8 to 3.3 × 10 −8 Ω m were calculated over 36.3 cm line length. These values are very close to bulk silver resistivity (1.6 × 10 −8 Ω m). Compared to previous research and commercial pastes, the newly formulated pastes reached equivalent or even better conductivities with lower silver content (70% by weight).

  4. Functionally Graded Ceramics Fabricated with Side-by-Side Tape Casting for Use in Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina; Bahl, Christian; Andersen, Kjeld Bøhm

    2015-01-01

    Functionally graded ceramic tapes have been fabricated by a side-by-side tape casting technique. This study shows the possibility and describes the main principles of adjacent coflow of slurries resulting in formation of thin plates of graded ceramic material. Results showed that the small...... variations of solvent and binder system concentrations have a substantial effect on slurry viscosity. Varying these parameters showed that side-by-side tape casting with a well-defined interface area is possible for slurries with viscosities above 3500 mPa s at a casting shear rate of 3.3 s -1...

  5. Automatic storing of single gamma spectra on magnetic tape. Programs LONGO, DIRE

    International Nuclear Information System (INIS)

    Los Arcos Merino, J. M.

    1978-01-01

    The program LONGO provides the block size and the block number in a binary file on magnetic tape. It has been applied to analyse the structure of the nine-track magnetic tapes storing single or coincidence gamma spectra files, recorded in octet form by a MULTI-8 minicomputer in the Nuclear Spectrometry Laboratory of J.E.N. Then the program DIRE has been written to transform the single gamma spectra into a new FASTRAND disk file, storing the information in-36 bit words. A copy of this file is obtained on magnetic tape and the single gamma spectra are then available by standard FORTRAN V reading sentences. (Author) 3 refs

  6. Microstructural dynamics of Bi-2223/Ag tapes annealed in 8% O2

    DEFF Research Database (Denmark)

    Andersen, L.G.; Poulsen, H.F.; Abrahamsen, A.B.

    2002-01-01

    The microstructural dynamics of Bi-2223 tapes are investigated in situ during annealing in 8% O-2 by means of 100 keV x-ray diffraction. A green mono- and a green multi-filamentary tape are annealed at 829.5 degreesC. During ramp-up (Ca,Sr)(2)PbO4 decomposes above 750 degreesC, resulting...... degreesC on quenched tapes shows a reaction over 3 weeks, whereby randomly oriented 3222 grains are formed and Bi-2223 is depleted of Pb. Simultaneously, the critical current decreases by a factor of 2....

  7. Ceramic tape casting: A review of current methods and trends with emphasis on rheological behaviour and flow analysis

    DEFF Research Database (Denmark)

    Jabbaribehnam, Mirmasoud; Bulatova, Regina; Tok, A. I Y

    2016-01-01

    Tape casting has been used to produce thin layers of ceramics that can be used as single layers or can be stacked and laminated into multilayered structures. Today, tape casting is the basic fabrication process that provides multilayered capacitors and multilayered ceramic packages. In tape casting...... fluid flow analysis of tape casting. In the present paper a review of the development of the tape casting process with particular focus on the rheological classifications as well as modelling the material flow is hence presented and in this context the current status is examined and future potential...

  8. Tack Measurements of Prepreg Tape at Variable Temperature and Humidity

    Science.gov (United States)

    Wohl, Christopher; Palmieri, Frank L.; Forghani, Alireza; Hickmott, Curtis; Bedayat, Houman; Coxon, Brian; Poursartip, Anoush; Grimsley, Brian

    2017-01-01

    NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly

  9. Black hole hair removal

    International Nuclear Information System (INIS)

    Banerjee, Nabamita; Mandal, Ipsita; Sen, Ashoke

    2009-01-01

    Macroscopic entropy of an extremal black hole is expected to be determined completely by its near horizon geometry. Thus two black holes with identical near horizon geometries should have identical macroscopic entropy, and the expected equality between macroscopic and microscopic entropies will then imply that they have identical degeneracies of microstates. An apparent counterexample is provided by the 4D-5D lift relating BMPV black hole to a four dimensional black hole. The two black holes have identical near horizon geometries but different microscopic spectrum. We suggest that this discrepancy can be accounted for by black hole hair - degrees of freedom living outside the horizon and contributing to the degeneracies. We identify these degrees of freedom for both the four and the five dimensional black holes and show that after their contributions are removed from the microscopic degeneracies of the respective systems, the result for the four and five dimensional black holes match exactly.

  10. The Black Studies Boondoggle

    Science.gov (United States)

    Long, Richard A.

    1970-01-01

    Indicates tendencies dangerous to the basic purpose of Black Studies, and identifies four external challeges--imperialism, paternalism, nihilism, and materialism. An internal challenge is considered to be the use of European and Establishment constructs to analyze black reality. (DM)

  11. Black-Body Radiation

    Indian Academy of Sciences (India)

    Keywords. Black-body radiation; thermal radiation; heat; electromagnetic radiation; Stefan's Law; Stefan–Boltzmann Law; Wien's Law; Rayleigh–Jeans Law; black-body spectrum; ultraviolet catastrophe; zero point energy; photon.

  12. A Model For The Absorption Of Thermal Radiation By Gold-Black

    OpenAIRE

    Quinlan, Brendan Robert

    2015-01-01

    The work presented here addresses an important topic in thermal radiation detection when gold-black is used as an absorber. Sought is a model to simulate the absorption of thermal radiation by gold-black. Fractal geometry is created to simulate the topology of gold-black. Then electrical circuits based on the topology are identified that capture the physics of the interaction between the gold-black material and incident electro-magnetic radiation. Parameters of the model are then adj...

  13. Classification of double-sided tapes used for X-ray fluorescence analysis of small samples according to composition

    International Nuclear Information System (INIS)

    Minami, Hideaki; Kadono, Jun'ichirou

    2017-01-01

    The composition of double-sided tapes available for X-ray fluorescence analysis was investigated and the double-sided tapes were classified into the detected composition. As a result, Na, Mg, Al, Si, P, S, Cl, K, Ca, Fe, Ti, Ag and Sr were detected from double-sided tapes; they could be classified into 4 types: 1) Si, S, Ca; 2) Na, Si, P, S, K; 3) Si, P, S and 4) Al, Ca. Double-sided tape made of polyester and polypropylene had fewer elemental component detected than that made of paper and non-woven fabric. Si derived from the release agent was detected with most double-sided tapes. Standard materials were measured with paper double-sided tape, which were affected by coexisting elements. On the other hand, when measuring a standard material with polypropylene double-sided tape, no influence of coexisting elements was observed. (author)

  14. Magnetic force microscopy image of Co-Cr-Ta layer in perpendicular magnetic tape at high linear recording density

    Science.gov (United States)

    Ishikawa, K.; Taguchi, R.; Miyashita, E.; Numazawa, J.; Ohshima, H.

    1997-04-01

    In this study, magnetic force microscopy (MFM) was used to investigate the recording capability of a perpendicular magnetic tape at a higher linear recording density. Perpendicular magnetic tapes with polyimide base sheets 10 μm thick were fabricated by a facing-target sputtering system [H. Yoshimoto, K. Kuga, Y. Yoneda, and J. Numazawa, J. Magn. Magn. Mater. 148, 357 (1995)]. A Co-Cr-Ta (200 nm) monolayered tape with a base sheet of excellent surface roughness was fabricated. A complete recorded bit pattern of 250 kfci was observed as a MFM image on the tape. A recorded bit pattern of 300 kfci was also observed. A Co-Cr-Ta/Ni-Fe (150/50 nm) multilayered tape was also fabricated. The remnant magnetization state on this tape at 50 kfci was improved by the presence of an underlayer (Ni-Fe) only 50 nm thick. The MFM image at 250 kfci was the same as with a monolayered tape.

  15. The immediate effects of proprioceptive neuromuscular facilitation with taping on gait parameters in patients with chronic stroke.

    Science.gov (United States)

    Park, Shin-Jun

    2017-11-01

    [Purpose] The purpose of the present study was to examine the immediate effects of simultaneous application of proprioceptive neuromuscular facilitation (PNF) and elastic taping (T), and the removal of the elastic tape, on the gait parameters of stroke patients. [Subjects and Methods] Twenty stroke patients were divided into a proprioceptive neuromuscular facilitation group (PNFG, n=7), a taping group (TG, n=6), and a proprioceptive neuromuscular facilitation with taping group (PNFTG, n=7). Relevant interventions were applied for 30 minutes, the tape was removed, and gait parameters were evaluated. [Results] Only the intervention of the PNFTG yielded significant differences in patient cadence, speed, and stride length. [Conclusion] The simultaneous application of PNF and taping for 30 minutes has carryover effects that can improve stroke patients' gait ability, even after the removal of the tape.

  16. Dynamics of black holes

    OpenAIRE

    Hayward, Sean A.

    2008-01-01

    This is a review of current theory of black-hole dynamics, concentrating on the framework in terms of trapping horizons. Summaries are given of the history, the classical theory of black holes, the defining ideas of dynamical black holes, the basic laws, conservation laws for energy and angular momentum, other physical quantities and the limit of local equilibrium. Some new material concerns how processes such as black-hole evaporation and coalescence might be described by a single trapping h...

  17. Black holes are hot

    International Nuclear Information System (INIS)

    Gibbons, G.

    1976-01-01

    Recent work, which has been investigating the use of the concept of entropy with respect to gravitating systems, black holes and the universe as a whole, is discussed. The resulting theory of black holes assigns a finite temperature to them -about 10 -7 K for ordinary black holes of stellar mass -which is in complete agreement with thermodynamical concepts. It is also shown that black holes must continuously emit particles just like ordinary bodies which have a certain temperature. (U.K.)

  18. Transobturator tape for female stress incontinence: A day surgery case

    Directory of Open Access Journals (Sweden)

    Al Taweel Waleed

    2009-01-01

    Full Text Available Aim: To evaluate the effectiveness of transobturator vaginal tape (TOT in the treatment of female stress urinary incontinence (SUI and to analyze functional results and quality of life after12 months follow up. Materials and Methods : All women with SUI who underwent TOT procedure from outside to inside under general or regional anesthesia from December 2004 to January 2007 were included in the study. All must have had a minimal follow up of one year. The patients were prospectively evaluated with history including pads use/day, physical examination - pelvic examination, urinalysis, urogenital distress inventory (UDI-6, and analog global satisfaction scale - and urodynamic studies - filling cystometry, pressure-flow studies, and Valsalva leak point pressure. Results: Sixty two consecutive patients who fulfilled the inclusion criteria underwent TOT procedure by one surgeon. The mean age was 52 ± 9 years (range, 34-70 years and minimal follow up was one year (12-24 months. The mean operative time was 17 ± 4 minutes (15-31 with average amount of bleeding 62 ± 22 cc. We found objectively 89% cure or improvement rate after one year. Conclusion: The out-in transobturator approach is a very effective treatment of SUI with low morbidity and high success rate. However, longer follow up in larger populations should assess the long-term reliability of this attractive procedure.

  19. Tape-wound toroidal (TF) magnet for ZEPHYR (Intermediate Report)

    International Nuclear Information System (INIS)

    Brossmann, U.; Gruber, J.E.; Haubenberger, W.D.; Jandl, O.; Soell, M.; Streibl, B.

    1979-11-01

    The report comprises three sections. Section A presents the essential features of the present design of a tape-wound magnet with respect to the magnetic, thermal and radiological loads resulting from the physical assumptions for the ZEPHYR experiment. The conceptual requirements for the liquid-nitrogen cooling of the magnet are given and concepts under discussion are presented. To allow a first pronouncement on the mechanical load capacity of critical magnet components, the results available from calculations and experiments relating to the conductor and insulation materials are interpreted. As investigation of the material properties must play an important role in consolidating the magnet concept, special sections of the report are devoted to this subject. Section B deals theoretically with the conductor material problem, reviews the available experimental results, both with respect to material properties and technical production, and takes a look ahead at future activities. The insulation material is treated on similar lines in Section C. (orig.) 891 HT/orig. 892 HIS

  20. Texture formation features of Bi(Pb)2223-Ag tapes

    International Nuclear Information System (INIS)

    Aksenova, T.D.; Bratukhin, P.V.; Shavkin, S.V.; Antipova, E.V.

    1993-01-01

    The powder-in-tube technique has proven to be the most successful method of fabrication long lengths of conductor utilizing ceramic high temperature superconductors. There have been numerous successful demonstrations that silver-clad Bi-Sr-Ca-Cu-O superconducting composites are able to overcome weak-link effects and carry high currents through formation of crystallographic texture. The thermomechanical process that has produced the best 2212-based conductors is fundamentally different from that used to produce the best (Pb)2223-based conductors. The 2212-based conductors with high J c have been produced with a partial-melt heat treatment while high-J c (Pb)2223-based conductors have been formed with repetitive deformation and annealing. For Bi2212-Ag composites we have proposed a new model of texture formation during partial melt process. The model is based on anisotropic Bi2212 crystalline growth from melt in quasi-two-dimensional volume and explains a wide set of experimental data. In this paper some features of texture formation in Bi(Pb)2223-Ag tapes are discussed. (orig.)

  1. Superconducting fault current limiter using high-resistive YBCO tapes

    International Nuclear Information System (INIS)

    Yazawa, T.; Koyanagi, K.; Takahashi, M.; Ono, M.; Toba, K.; Takigami, H.; Urata, M.; Iijima, Y.; Saito, T.; Ameniya, N.; Shiohara, Y.

    2008-01-01

    One of the programs in the Ministry of Economy and Trade and Industry (METI) project regarding R and D on YBCO conductor is to evaluate the applicability of the developed conductor toward several applications. This paper focuses on a fault current limiter (FCL) as one of the expected power applications. YBCO tape conductors with ion beam assisted deposition (IBAD) substrate are used in this work. In order to obtain high resistance of the conductor, which is preferable to an FCL, the thickness of the protecting layer made of silver was decreased as possible. Then high-resistive metal stabilizing layer is attached on the silver layer to improve stability. Obtaining the relevant current limiting performance on short sample experiments, model coils were developed to aim the 6.6 kV-class FCL. Short circuit experiments were implemented with a short circuit generator. The coil successfully restricted the short circuit current over 17 kA to about 700 A by the applied voltage of 3.8 kV, which is nominal phase-to-ground voltage. The experimental results show good agreement with computer analyses and show promising toward the application

  2. Cracking of Beams Strengthened with Externally Bonded SRP Tapes

    Science.gov (United States)

    Krzywoń, Rafał

    2017-10-01

    Paper discusses strengthening efficiency of relatively new kind of SRP composite based on high strength steel wires. They are made of ultra-high strength steel primarily used in cords of car tires. Through advanced treatment, the mechanical properties of SRP steel are similar to other high carbon cold drawn steels used in construction industry. Strength significantly exceed 2000 MPa, there is no perfect plasticity at yield stress level. Almost linear stress-strain relationship makes SRP steel mechanical properties similar to carbon fibers. Also flexibility and weight ratio of the composite overlay is slightly worse than CFRP strip. Despite these advantages SRP is not as popular as other composites reinforced with fibers of high strength. This is due to the small number of studies of SRP behavior and applicability. Paper shows selected results of the laboratory test of beams strengthened with use of SRP and CFRP externally bonded overlays. Attention has been focused primarily on the phenomenon of cracking. Comparison include the cracking moment, crack width and spacing, coverage of crack zone. Despite the somewhat lower rigidity of SRP tapes, they have a much better adhesion to concrete, so that the crack width is comparable in almost the whole load range. The paper also includes an assessment of the common methods of checking the condition of cracking in relation to the tested SRP strengthening. The paper presents actual calculation procedures to determine the crack spacing and crack width. The discussed formulas are verified with results of provided laboratory tests.

  3. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A.; Lstiburek, J.

    2014-09-01

    This guide provides information and recommendations to the following groups: insulation contractors; general contractors; builders; home remodelers; mechanical contractors; and homeowners, as a guide to the work that needs to be done. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues. And durability issues are more important than saving energy. Not all techniques can apply to all houses. Special conditions will require special action. Some builders or homeowners will wish to do more than the important but basic retrofit strategies outlined by this guide. The following are best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant items were discussed with the group which are required to make taped insulating sheathing a simple, long term, and durable drainage plane: 1. Horizontal joints should be limited or eliminated wherever possible; 2. Where a horizontal joint exists use superior materials; 3. Frequent installation inspection and regular trade training are required to maintain proper installation. Section 5 of this measure guideline contains the detailed construction procedure for the three recommended methods to effectively seal the joints in exterior insulating sheathing to create a simple, long term, and durable drainage plane.

  4. Tape Mbo´e: A First Experimental Assessment

    Directory of Open Access Journals (Sweden)

    Ilse Grau

    2015-04-01

    Full Text Available The development of software not only needs to consider the construction process, but also other aspects such as cost, human resources and communication among stakeholders. The lack of simplicity into this context becomes explicit when some restrictions, such as service oriented architecture, must be considered as the basic style to build sustainable applications into environments were practitioners are not aware of this software technology. In addition to this, most of the available software processes are not directly applicable nor are they reusable, so learning times becomes risk for the development of the project. Therefore, Tape Mbo´e (TME has been proposed to support the building of such applications, into development environments like developing countries where we can have economic constraints and scarcity of proficient practitioners. The first application of TME has been to develop a service-based application whose goal is to provide the interoperability among legacy systems of different public agencies in Paraguay. Initial results of this experience indicated the feasibility and simplicity of TME when applied in this field. The evaluation process, its results and conclusions are described in this paper.

  5. Electrical Injuries

    Science.gov (United States)

    ... how quickly you get treatment. Causes of electrical injuries include Lightning strikes Faulty electrical appliances Work-related exposures Contact with household wiring or power lines Accidents in small children, when they bite or suck on electrical cords, ...

  6. Acute barrier disruption by adhesive tapes is influenced by pressure, time and anatomical location: integrity and cohesion assessed by sequential tape stripping. A randomized, controlled study.

    Science.gov (United States)

    Breternitz, M; Flach, M; Prässler, J; Elsner, P; Fluhr, J W

    2007-02-01

    Tape stripping is an established procedure in stratum corneum (SC) physiology research. Adhesive films are pressed to the surface of the skin and then removed. The superficial layers of the SC adhere to the film and are accessible for further investigations. Although this method is widely used, only scant information about standardization is known. Various protocols are used but are difficult to compare. The aim of the present study was to investigate the effects of the type of tape, pressure, time, anatomical site and type of applied pressure. Twelve healthy volunteers (age range 20-31 years) were entered in a randomized, controlled study with sequential tape stripping at the volar forearm, upper arm, cheek and back. Different methods (roller, stamp, thumb, stretched skin), total duration of applied pressure (2 s, 10 s), degrees of pressure (2 N stamp, 7 N stamp) and different tapes (D-Squame, Corneofix, Blenderm) were investigated and the impact on barrier function assessed by transepidermal water loss measurements. Furthermore, measurements of SC hydration, skin colour and skin surface pH were performed. Spectroscopic measurements and a Bradford protein assay to determine the mass of removed SC were carried out in parallel. The degree of barrier disruption, irritation and SC cohesion is influenced by the character of adhesive tapes, total duration of applied pressure (2 s, 10 s; 2 N, 7 N), the kind of method for pressure application (roller, stamp, thumb, stretched skin), anatomical site and condition before stripping (occlusion vs. nonocclusion). The spectroscopic assessment and Bradford protein assay determination showed a significant correlation (P tape strips on the volar forearm and then discarding the first and second strips. This approach allows the performance of a standardized study with a reasonable amount of resources.

  7. Monopole black hole skyrmions

    OpenAIRE

    Moss, I.G.; Shiiki, N.; Winstanley, E.

    2000-01-01

    Charged black hole solutions with pion hair are discussed. These can be\\ud used to study monopole black hole catalysis of proton decay.\\ud There also exist\\ud multi-black hole skyrmion solutions with BPS monopole behaviour.

  8. Alcoholism and Blacks.

    Science.gov (United States)

    Mosley, Bertha; And Others

    1988-01-01

    Notes that in America, knowledge base concerning alcoholism is concentrated on drinking patterns of Whites, and that Black Americans often differ in their drinking behavior, resulting in a need to clarify issues regarding alcoholism and Blacks. Provides theoretical information useful in better discerning drinking behavior of Blacks. (Author/NB)

  9. What is black hole?

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. What is black hole? Possible end phase of a star: A star is a massive, luminous ball of plasma having continuous nuclear burning. Star exhausts nuclear fuel →. White Dwarf, Neutron Star, Black Hole. Black hole's gravitational field is so powerful that even ...

  10. Genocide and Black Ecology

    Science.gov (United States)

    Sinnette, Calvin H.

    1972-01-01

    Contends that the survival of black people is in serious jeopardy as is evidenced in contemporary discussions on the worldwide plight of black people, and that an exhaustive study of the problem in its many dimensions is seriously lacking; the moral and ethical issues of genocide require examination from a black perspective. (JW)

  11. Smart Tape For Structural Health Monitoring of Rocket Engines, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Acellent Technologies, Inc. proposes to develop a SMART TAPE system that can be used to perform rapid non-destructive evaluation in real time and provide long-term...

  12. Performance Assessment in a Heat Exchanger Tube with Opposite/Parallel Wing Twisted Tapes

    Directory of Open Access Journals (Sweden)

    S. Eiamsa-ard

    2015-02-01

    Full Text Available The thermohydraulic performance in a tube containing a modified twisted tape with alternate-axes and wing arrangements is reported. This work aims to investigate the effects of wing arrangements (opposite (O and parallel (P wings at different wing shapes (triangle (Tri, rectangular (Rec, and trapezoidal (Tra wings and on the thermohydraulic performance characteristics. The obtained results show that wing twisted tapes with all wing shape arrangements (O-Tri/O-Rec/O-Tra/P-Tri/P-Rec/P-Tra give superior thermohydraulic performance and heat transfer rate to the typical twisted tape. In addition, the tapes with opposite wing arrangement of O-Tra, O-Rec, and O-Tri give superior thermohydraulic performances to those with parallel wing arrangement of P-Tra, P-Rec, and P-Tri around 2.7%, 3.5%, and 3.2%, respectively.

  13. Effects of Tape-Recording & Supervisory Evaluation on Counselor Trainee Anxiety Levels.

    Science.gov (United States)

    Bowman, James T.; Roberts, Gayle T.

    1979-01-01

    Counselors, enrolled in supervised counseling practica, participated in a study to assess subjective and physiological anxiety responses to counseling under different stimulus conditions. Tape-recording and supervisory evaluation did not increase the anxiety levels of participants. (Author)

  14. The Use of the Portable Television Tape Recorder in Science Education

    Science.gov (United States)

    Sund, Robert B.

    1969-01-01

    Reviews the many uses of video tape recordings in science education such as (1) teacher improvement, (2) training prospective science teachers, (3) educational research, (4) testing, (5) supervision of student teachers, and (6) teacher placement. (LC)

  15. Fabrication of high edge-definition steel-tape gratings for optical encoders

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  16. The effect of kinesio taping in forward bending of the lumbar spine.

    Science.gov (United States)

    Lemos, Thiago Vilela; Albino, Anna Carolina Gonçalves; Matheus, Joao Paulo C; Barbosa, Aurélio de Melo

    2014-09-01

    [Purpose] The aim of this study was to evaluate the influence of a lumbar fascia Kinesio Taping(®) technique forward bending range of motion. [Subjects and Methods] This was a longitudinal study with a randomized clinical trial composed of 39 subjects divided into three groups (control, Kinesio Without Tension-KWT, and Kinesio Fascia Correction-KFC). The subjects were assessed by Schober and fingertip-to-floor tests and left the tape in place for 48 hours before being reassessed 24 hours, 48 hours and 30 days after its removal. [Results] In all three experimental groups no significant differences were observed with the Schober test, but it was possible to observe an increase in lumbar flexion after 30 days. With the fingertip-to-floor distance assessment, the KFC and KWT groups showed significantly improved flexibility 24 hours and 48 hours after tape removal. [Conclusion] The Kinesio Taping(®) influenced fascia mobility, allowing for slight improvement of lumbar flexibility.

  17. SMART Tape For Structural Health Monitoring of Rocket Engines, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Acellent Technologies, Inc. proposes to develop a SMART Tape system that can be used to perform rapid non-destructive evaluation in real time and provide long-term...

  18. Archive of Census Related Products (ACRP): 1990 Summary Tape File (STF1B)

    Data.gov (United States)

    National Aeronautics and Space Administration — The 1990 Summary Tape File (STF1B) portion of the Archive of Census Related Products (ACRP) contains population and housing data, along with additional demographic...

  19. Application of tape unit in data acquisition system and its maintenance and trouble shoot

    International Nuclear Information System (INIS)

    Xing Jianping; Qian Xicheng

    1995-01-01

    Application of magnetic tape unit in data acquisition system of DEC computer imported from German and its maintenance as well as trouble shoot is described. The system is used for nuclear data acquisition and processing

  20. Are marketed topical metronidazole creams bioequivalent? Evaluation by in vivo microdialysis sampling and tape stripping methodology

    DEFF Research Database (Denmark)

    Garcia Ortiz, Patricia Elodia; Hansen, S H; Shah, Surendra P.

    2011-01-01

    To evaluate the bioequivalence of 3 marketed topical metronidazole formulations by simultaneous dermal microdialysis and stratum corneum sampling by the tape stripping methodology, and to compare the techniques as tools for the determination of bioequivalence....