Directory of Open Access Journals (Sweden)
Yang Qiang
2014-01-01
Full Text Available This study was aimed to develop an ECM-derived biphasic scaffold and to investigate its regeneration potential loaded with BM-MSCs in repair of large, high-load-bearing osteochondral defects of the canine femoral head. The scaffolds were fabricated using cartilage and bone ECM as a cartilage and bone layer, respectively. Osteochondral constructs were fabricated using induced BM-MSCs and the scaffold. Osteochondral defects (11 mm diameter × 10 mm depth were created on femoral heads of canine and treated with the constructs. The repaired tissue was evaluated for gross morphology, radiography, histological, biomechanics at 3 and 6 months after implantation. Radiography revealed that femoral heads slightly collapsed at 3 months and severely collapsed at 6 months. Histology revealed that some defects in femoral heads were repaired, but with fibrous tissue or fibrocartilage, and femoral heads with different degrees of collapse. The bone volume fraction was lower for subchondral bone than normal femoral bone at 3 and 6 months. Rigidity was lower in repaired subchondral bone than normal femoral bone at 6 months. The ECM-derived, biphasic scaffold combined with induced BM-MSCs did not successfully repair large, high-load-bearing osteochondral defects of the canine femoral head. However, the experience can help improve the technique of scaffold fabrication and vascularization.
Kon, Elizaveta; Robinson, Dror; Verdonk, Peter; Drobnic, Matej; Patrascu, Jenel Mariano; Dulic, Oliver; Gavrilovic, Gordon; Filardo, Giuseppe
2016-12-01
Chondral and osteochondral lesions represent a debilitating disease. Untreated lesions remain a risk factor for more extensive joint damage. The objective of this clinical study is to evaluate safety and early results of an aragonite-based scaffold used for osteochondral unit repair, by analysing both clinical outcome and MRI results, as well as the benefits of the procedure optimization through novel tapered shaped implants. A crystalline aragonite bi-phasic scaffold was implanted in patients affected by focal chondral-osteochondral knee lesions of the condyle and trochlea. Twenty-one patients (17 men, 4 women with a mean age of 31.0 ± 8.6 years) without severe OA received tapered shaped implants for the treatment of 2.5 ±1.7 cm 2 sized defects. The control group consisted of 76 patients selected according to the same criteria from a database of patients who previously underwent implantation of cylindrical-shaped implants. The clinical outcome of all patients was evaluated with the IKDC subjective score, the Lysholm score, and all 5 KOOS subscales administered preoperatively and at 6 and 12 months after surgery, while MRI evaluation was performed at the 12 month follow-up. A statistically significant improvement in all clinical scores was documented both in the tapered implants and the cylindrical group. No difference could be detected in the comparison between the improvement obtained with the two implant types, neither in the clinical nor in imaging evaluations. A difference could be detected instead in terms of revision rate, which was lower in the tapered implant group with no implant removal - 0% vs 8/76-10.5% failures in the cylindrical implants. This study highlighted both safety and potential of a novel aragonite-based scaffold for the treatment of chondral and osteochondral lesions in humans. A tapered shape relative to the cylindrical shaped implant design, improved the scaffold's safety profile. Tapered scaffolds maintain the clinical improvement
Simple geometry tribological study of osteochondral graft implantation in the knee.
Bowland, Philippa; Ingham, Eileen; Fisher, John; Jennings, Louise M
2018-03-01
Robust preclinical test methods involving tribological simulations are required to investigate and understand the tribological function of osteochondral repair interventions in natural knee tissues. The aim of this study was to investigate the effects of osteochondral allograft implantation on the local tribology (friction, surface damage, wear and deformation) of the tissues in the natural knee joint using a simple geometry, reciprocating pin-on-plate friction simulator. In addition, the study aimed to assess the ability of osteochondral grafts to restore a low surface damage, deformation and wear articulation when compared to the native state. A method was developed to characterise and quantify surface damage wear and deformation of the opposing cartilage-bone pin surface using a non-contacting optical profiler (Alicona Infinite Focus). Porcine 12 mm diameter cartilage-bone pins were reciprocated against bovine cartilage-bone plates that had 6 mm diameter osteochondral allografts, cartilage defects or stainless steel pins (positive controls) inserted centrally. Increased levels of surface damage with changes in geometry were not associated with significant increases in the coefficient of dynamic friction. Significant damage to the opposing cartilage surface was observed in the positive control groups. Cartilage damage, deformation and wear (as measured by change in geometry) in the xenograft (2.4 mm 3 ) and cartilage defect (0.99 mm 3 ) groups were low and not significantly different (p > 0.05) compared to the negative control in either group. The study demonstrated the potential of osteochondral grafts to restore the congruent articular surface and biphasic tribology of the natural joint. An optical method has been developed to characterise cartilage wear, damage and deformation that can be applied to the tribological assessment of osteochondral grafts in a whole natural knee joint simulation model.
Babur, Betul Kul; Futrega, Kathryn; Lott, William B; Klein, Travis Jacob; Cooper-White, Justin; Doran, Michael Robert
2015-09-01
Engineered biphasic osteochondral tissues may have utility in cartilage defect repair. As bone-marrow-derived mesenchymal stem/stromal cells (MSC) have the capacity to make both bone-like and cartilage-like tissues, they are an ideal cell population for use in the manufacture of osteochondral tissues. Effective differentiation of MSC to bone-like and cartilage-like tissues requires two unique medium formulations and this presents a challenge both in achieving initial MSC differentiation and in maintaining tissue stability when the unified osteochondral tissue is subsequently cultured in a single medium formulation. In this proof-of-principle study, we used an in-house fabricated microwell platform to manufacture thousands of micropellets formed from 166 MSC each. We then characterized the development of bone-like and cartilage-like tissue formation in the micropellets maintained for 8-14 days in sequential combinations of osteogenic or chondrogenic induction medium. When bone-like or cartilage-like micropellets were induced for only 8 days, they displayed significant phenotypic changes when the osteogenic or chondrogenic induction medium, respectively, was swapped. Based on these data, we developed an extended 14-day protocol for the pre-culture of bone-like and cartilage-like micropellets in their respective induction medium. Unified osteochondral tissues were formed by layering 12,000 osteogenic micropellets and 12,000 chondrogenic micropellets into a biphasic structure and then further culture in chondrogenic induction medium. The assembled tissue was cultured for a further 8 days and characterized via histology. The micropellets had amalgamated into a continuous structure with distinctive bone-like and cartilage-like regions. This proof-of-concept study demonstrates the feasibility of micropellet assembly for the formation of osteochondral-like tissues for possible use in osteochondral defect repair.
Verhaegen, J; Clockaerts, S; Van Osch, G J V M; Somville, J; Verdonk, P; Mertens, P
2015-01-01
Treatment of osteochondral defects remains a challenge in orthopedic surgery. The TruFit plug has been investigated as a potential treatment method for osteochondral defects. This is a biphasic scaffold designed to stimulate cartilage and subchondral bone formation. The aim of this study is to investigate clinical, radiological, and histological efficacy of the TruFit plug in restoring osteochondral defects in the joint. We performed a systematic search in five databases for clinical trials in which patients were treated with a TruFit plug for osteochondral defects. Studies had to report clinical, radiological, or histological outcome data. Quality of the included studies was assessed. Five studies describe clinical results, all indicating improvement at follow-up of 12 months compared to preoperative status. However, two studies reporting longer follow-up show deterioration of early improvement. Radiological evaluation indicates favorable MRI findings regarding filling of the defect and incorporation with adjacent cartilage at 24 months follow-up, but conflicting evidence exists on the properties of the newly formed overlying cartilage surface. None of the included studies showed evidence for bone ingrowth. The few histological data available confirmed these results. There are no data available that support superiority or equality of TruFit compared to conservative treatment or mosaicplasty/microfracture. Further investigation is needed to improve synthetic biphasic implants as therapy for osteochondral lesions. Randomized controlled clinical trials comparing TruFit plugs with an established treatment method are needed before further clinical use can be supported.
Clockaerts, S.; Van Osch, G.J.V.M.; Somville, J.; Verdonk, P.; Mertens, P.
2015-01-01
Objective: Treatment of osteochondral defects remains a challenge in orthopedic surgery. The TruFit plug has been investigated as a potential treatment method for osteochondral defects. This is a biphasic scaffold designed to stimulate cartilage and subchondral bone formation. The aim of this study is to investigate clinical, radiological, and histological efficacy of the TruFit plug in restoring osteochondral defects in the joint. Design: We performed a systematic search in five databases for clinical trials in which patients were treated with a TruFit plug for osteochondral defects. Studies had to report clinical, radiological, or histological outcome data. Quality of the included studies was assessed. Results: Five studies describe clinical results, all indicating improvement at follow-up of 12 months compared to preoperative status. However, two studies reporting longer follow-up show deterioration of early improvement. Radiological evaluation indicates favorable MRI findings regarding filling of the defect and incorporation with adjacent cartilage at 24 months follow-up, but conflicting evidence exists on the properties of the newly formed overlying cartilage surface. None of the included studies showed evidence for bone ingrowth. The few histological data available confirmed these results. Conclusion: There are no data available that support superiority or equality of TruFit compared to conservative treatment or mosaicplasty/microfracture. Further investigation is needed to improve synthetic biphasic implants as therapy for osteochondral lesions. Randomized controlled clinical trials comparing TruFit plugs with an established treatment method are needed before further clinical use can be supported. PMID:26069706
Strategies for osteochondral repair: Focus on scaffolds
Directory of Open Access Journals (Sweden)
Seog-Jin Seo
2014-07-01
Full Text Available Interest in osteochondral repair has been increasing with the growing number of sports-related injuries, accident traumas, and congenital diseases and disorders. Although therapeutic interventions are entering an advanced stage, current surgical procedures are still in their infancy. Unlike other tissues, the osteochondral zone shows a high level of gradient and interfacial tissue organization between bone and cartilage, and thus has unique characteristics related to the ability to resist mechanical compression and restoration. Among the possible therapies, tissue engineering of osteochondral tissues has shown considerable promise where multiple approaches of utilizing cells, scaffolds, and signaling molecules have been pursued. This review focuses particularly on the importance of scaffold design and its role in the success of osteochondral tissue engineering. Biphasic and gradient composition with proper pore configurations are the basic design consideration for scaffolds. Surface modification is an essential technique to improve the scaffold function associated with cell regulation or delivery of signaling molecules. The use of functional scaffolds with a controllable delivery strategy of multiple signaling molecules is also considered a promising therapeutic approach. In this review, we updated the recent advances in scaffolding approaches for osteochondral tissue engineering.
Barbeck, Mike; Serra, Tiziano; Booms, Patrick; Stojanovic, Sanja; Najman, Stevo; Engel, Elisabeth; Sader, Robert; Kirkpatrick, Charles James; Navarro, Melba; Ghanaati, Shahram
2017-12-01
The aim of the present study was the in vitro and in vivo analysis of a bi-layered 3D-printed scaffold combining a PLA layer and a biphasic PLA/bioglass G5 layer for regeneration of osteochondral defects in vivo Focus of the in vitro analysis was on the (molecular) weight loss and the morphological and mechanical variations after immersion in SBF. The in vivo study focused on analysis of the tissue reactions and differences in the implant bed vascularization using an established subcutaneous implantation model in CD-1 mice and established histological and histomorphometrical methods. Both scaffold parts kept their structural integrity, while changes in morphology were observed, especially for the PLA/G5 scaffold. Mechanical properties decreased with progressive degradation, while the PLA/G5 scaffolds presented higher compressive modulus than PLA scaffolds. The tissue reaction to PLA included low numbers of BMGCs and minimal vascularization of its implant beds, while the addition of G5 lead to higher numbers of BMGCs and a higher implant bed vascularization. Analysis revealed that the use of a bi-layered scaffold shows the ability to observe distinct in vivo response despite the physical proximity of PLA and PLA/G5 layers. Altogether, the results showed that the addition of G5 enables to reduce scaffold weight loss and to increase mechanical strength. Furthermore, the addition of G5 lead to a higher vascularization of the implant bed required as basis for bone tissue regeneration mediated by higher numbers of BMGCs, while within the PLA parts a significantly lower vascularization was found optimally for chondral regeneration. Thus, this data show that the analyzed bi-layered scaffold may serve as an ideal basis for the regeneration of osteochondral tissue defects. Additionally, the results show that it might be able to reduce the number of experimental animals required as it may be possible to analyze the tissue response to more than one implant in one
In vivo outcomes of tissue-engineered osteochondral grafts.
Bal, B Sonny; Rahaman, Mohamed N; Jayabalan, Prakash; Kuroki, Keiichi; Cockrell, Mary K; Yao, Jian Q; Cook, James L
2010-04-01
Tissue-engineered osteochondral grafts have been synthesized from a variety of materials, with some success at repairing chondral defects in animal models. We hypothesized that in tissue-engineered osteochondral grafts synthesized by bonding mesenchymal stem cell-loaded hydrogels to a porous material, the choice of the porous scaffold would affect graft healing to host bone, and the quality of cell restoration at the hyaline cartilage surface. Bone marrow-derived allogeneic mesenchymal stem cells were suspended in hydrogels that were attached to cylinders of porous tantalum metal, allograft bone, or a bioactive glass. The tissue-engineered osteochondral grafts, thus created were implanted into experimental defects in rabbit knees. Subchondral bone restoration, defect fill, bone ingrowth-implant integration, and articular tissue quality were compared between the three subchondral materials at 6 and 12 weeks. Bioactive glass and porous tantalum were superior to bone allograft in integrating to adjacent host bone, regenerating hyaline-like tissue at the graft surface, and expressing type II collagen in the articular cartilage.
Current strategies in multiphasic scaffold design for osteochondral tissue engineering: A review.
Yousefi, Azizeh-Mitra; Hoque, Md Enamul; Prasad, Rangabhatala G S V; Uth, Nicholas
2015-07-01
The repair of osteochondral defects requires a tissue engineering approach that aims at mimicking the physiological properties and structure of two different tissues (cartilage and bone) using specifically designed scaffold-cell constructs. Biphasic and triphasic approaches utilize two or three different architectures, materials, or composites to produce a multilayered construct. This article gives an overview of some of the current strategies in multiphasic/gradient-based scaffold architectures and compositions for tissue engineering of osteochondral defects. In addition, the application of finite element analysis (FEA) in scaffold design and simulation of in vitro and in vivo cell growth outcomes has been briefly covered. FEA-based approaches can potentially be coupled with computer-assisted fabrication systems for controlled deposition and additive manufacturing of the simulated patterns. Finally, a summary of the existing challenges associated with the repair of osteochondral defects as well as some recommendations for future directions have been brought up in the concluding section of this article. © 2014 Wiley Periodicals, Inc.
A New Biphasic Dicalcium Silicate Bone Cement Implant
Directory of Open Access Journals (Sweden)
Fausto Zuleta
2017-07-01
Full Text Available This study aimed to investigate the processing parameters and biocompatibility of a novel biphasic dicalcium silicate (C2S cement. Biphasic α´L + β-C2Sss was synthesized by solid-state processing, and was used as a raw material to prepare the cement. In vitro bioactivity and biocompatibility studies were assessed by soaking the cement samples in simulated body fluid (SBF and human adipose stem cell cultures. Two critical-sized defects of 6 mm Ø were created in 15 NZ tibias. A porous cement made of the high temperature forms of C2S, with a low phosphorous substitution level, was produced. An apatite-like layer covered the cement’s surface after soaking in SBF. The cell attachment test showed that α´L + β-C2Sss supported cells sticking and spreading after 24 h of culture. The cement paste (55.86 ± 0.23 obtained higher bone-to-implant contact (BIC percentage values (better quality, closer contact in the histomorphometric analysis, and defect closure was significant compared to the control group (plastic. The residual material volume of the porous cement was 35.42 ± 2.08% of the initial value. The highest BIC and bone formation percentages were obtained on day 60. These results suggest that the cement paste is advantageous for initial bone regeneration.
The use of PLDLA/PCL-T scaffold to repair osteochondral defects in vivo
Directory of Open Access Journals (Sweden)
Andrea Rodrigues Esposito
2012-01-01
Full Text Available The physiological repair of osteochondral lesions requires the development of a scaffold that is compatible with the structure of the damaged tissue, cartilage and bone. The aim of this study was to evaluate the biological performance of a PLDLA/PCL-T (90/10 scaffold for repairing osteochondral defects in rabbits. Polymeric scaffolds containing saccharose (75% w/v were obtained by solvent casting and then implanted in the medial knee condyles of 12 New Zealand rabbits after osteochondral damage with a trephine metallic drill (diameter: 3.3 mm in both medial femoral condyles. Each rabbit received the same treatment, i.e., the polymeric scaffold was implanted on the right side while no material was implanted on the left side (control. Four and 12 weeks later histological examination revealed bone neoformation in the implant group, with the presence of hyaline cartilage and mesenchymal tissue. In contrast, the control group showed bone neoformation with necrosis, exacerbated superficial fibrosis, inflammation and cracks in the neoformed tissue. These findings indicate that the PLDLA/PCL-T scaffold was biocompatible and protected the condyles by stabilizing the lesion and allowing subchondral bone tissue and hyaline cartilage formation.
Lee, Whitaik David; Gawri, Rahul; Pilliar, Robert M; Stanford, William L; Kandel, Rita A
2017-10-15
Integration of in vitro-formed cartilage on a suitable substrate to form tissue-engineered implants for osteochondral defect repair is a considerable challenge. In healthy cartilage, a zone of calcified cartilage (ZCC) acts as an intermediary for mechanical force transfer from soft to hard tissue, as well as an effective interlocking structure to better resist interfacial shear forces. We have developed biphasic constructs that consist of scaffold-free cartilage tissue grown in vitro on, and interdigitated with, porous calcium polyphosphate (CPP) substrates. However, as CPP degrades, it releases inorganic polyphosphates (polyP) that can inhibit local mineralization, thereby preventing the formation of a ZCC at the interface. Thus, we hypothesize that coating CPP substrate with a layer of hydroxyapatite (HA) might prevent or limit this polyP release. To investigate this we tested both inorganic or organic sol-gel processing methods, asa barrier coating on CPP substrate to inhibit polyP release. Both types of coating supported the formation of ZCC in direct contact with the substrate, however the ZCC appeared more continuous in the tissue formed on the organic HA sol gel coated CPP. Tissues formed on coated substrates accumulated comparable quantities of extracellular matrix and mineral, but tissues formed on organic sol-gel (OSG)-coated substrates accumulated less polyP than tissues formed on inorganic sol-gel (ISG)-coated substrates. Constructs formed with OSG-coated CPP substrates had greater interfacial shear strength than those formed with ISG-coated and non-coated substrates. These results suggest that the OSG coating method can modify the location and distribution of ZCC and can be used to improve the mechanical integrity of tissue-engineered constructs formed on porous CPP substrates. Articular cartilage interfaces with bone through a zone of calcified cartilage. This study describes a method to generate an "osteochondral-like" implant that mimics this
Effects of osteochondral defect size on cartilage regeneration using a double-network hydrogel.
Higa, Kotaro; Kitamura, Nobuto; Goto, Keiko; Kurokawa, Takayuki; Gong, Jian Ping; Kanaya, Fuminori; Yasuda, Kazunori
2017-05-22
There has been increased interest in one-step cell-free procedures to avoid the problems related to cell manipulation and its inherent disadvantages. We have studied the chondrogenic induction ability of a PAMPS/PDMAAm double-network (DN) gel and found it to induce chondrogenesis in animal osteochondral defect models. The purpose of this study was to investigate whether the healing process and the degree of cartilage regeneration induced by the cell-free method using DN gel are influenced by the size of osteochondral defects. A total of 63 mature female Japanese white rabbits were used in this study, randomly divided into 3 groups of 21 rabbits each. A 2.5-mm diameter osteochondral defect was created in the femoral trochlea of the patellofemoral joint of bilateral knees in Group I, a 4.3-mm osteochondral defect in Group II, and a 5.8-mm osteochondral defect in Group III. In the right knee of each animal, a DN gel plug was implanted so that a vacant space of 2-mm depth was left above the plug. In the left knee, we did not conduct any treatment to obtain control data. Animals were sacrificed at 2, 4, and 12 weeks after surgery, and gross and histological evaluations were made. The present study demonstrated that all sizes of the DN gel implanted defects as well as the 2.5mm untreated defects showed cartilage regeneration at 4 and 12 weeks. The 4.3-mm and 5.8-mm untreated defects did not show cartilage regeneration during the 12-week period. The quantitative score reported by O'Driscoll et al. was significantly higher in the 4.3-mm and 5.8-mm DN gel-implanted defects than the untreated defects at 4 and 12 weeks (p regeneration in defects between 2.5 and 5.8 mm, offering a promising device to establish a cell-free cartilage regeneration therapy and applicable to various sizes of osteochondral defects.
Magnetic resonance imaging of hyaline cartilage regeneration in neocartilage graft implantation.
Tan, C F; Ng, K K; Ng, S H; Cheung, Y C
2003-12-01
The purpose of this study was to investigate the regenerative potential of hyaline cartilage in a neocartilage graft implant with the aid of MR cartilage imaging using a rabbit model. Surgical osteochondral defects were created in the femoral condyles of 30 mature New Zealand rabbits. The findings of neocartilage in autologous cartilage grafts packed into osteochondral defects were compared with control group of no implant to the osteochondral defect. The outcome of the implantations was correlated with histologic and MR cartilage imaging findings over a 3-month interval. Neocartilage grafts packed into osteochondral defects showed regeneration of hyaline cartilage at the outer layer of the implant using MR cartilage imaging. Fibrosis of fibrocartilage developed at the outer layer of the autologous cartilage graft together with an inflammatory reaction within the osteochondral defect. This animal study provides evidence of the regenerative ability of hyaline cartilage in neocartilage transplants to repair articular cartilage.
Porous titanium bases for osteochondral tissue engineering
Nover, Adam B.; Lee, Stephanie L.; Georgescu, Maria S.; Howard, Daniel R.; Saunders, Reuben A.; Yu, William T.; Klein, Robert W.; Napolitano, Anthony P.; Ateshian, Gerard A.
2015-01-01
Tissue engineering of osteochondral grafts may offer a cell-based alternative to native allografts, which are in short supply. Previous studies promote the fabrication of grafts consisting of a viable cell-seeded hydrogel integrated atop a porous, bone-like metal. Advantages of the manufacturing process have led to the evaluation of porous titanium as the bone-like base material. Here, porous titanium was shown to support the growth of cartilage to produce native levels of Young’s modulus, using a clinically relevant cell source. Mechanical and biochemical properties were similar or higher for the osteochondral constructs compared to chondral-only controls. Further investigation into the mechanical influence of the base on the composite material suggests that underlying pores may decrease interstitial fluid pressurization and applied strains, which may be overcome by alterations to the base structure. Future studies aim to optimize titanium-based tissue engineered osteochondral constructs to best match the structural architecture and strength of native grafts. Statement of Significance The studies described in this manuscript follow up on previous studies from our lab pertaining to the fabrication of osteochondral grafts that consist of a bone-like porous metal and a chondrocyte-seeded hydrogel. Here, tissue engineered osteochondral grafts were cultured to native stiffness using adult chondrocytes, a clinically relevant cell source, and a porous titanium base, a material currently used in clinical implants. This porous titanium is manufactured via selective laser melting, offering the advantages of precise control over shape, pore size, and orientation. Additionally, this manuscript describes the mechanical influence of the porous base, which may have applicability to porous bases derived from other materials. PMID:26320541
Torrie, Arissa M; Kesler, William W; Elkin, Joshua; Gallo, Robert A
2015-12-01
Over the past decade, osteochondral allograft transplantation has soared in popularity. Advances in storage techniques have demonstrated improved chondrocyte viability at longer intervals and allowed for potential of increased graft availability. Recent studies have stratified outcomes according to location and etiology of the chondral or osteochondral defect. Unipolar lesions generally have favorable outcomes with promising 10-year survival rates. Though those undergoing osteochondral allograft transplantation often require reoperation, patient satisfaction remains high.
Radiologic findings of osteochondritis dissecans
Energy Technology Data Exchange (ETDEWEB)
Kim, Jae Seung; Choi, Choong Gon; Kang, Heung Sik; Lee, Seon Kyu; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)
1993-05-15
To evaluate the radiographic characteristics of osteochondritis dissecans (OCD) and useful parameter for predicting mechanical stability, we retrospectively analysed 26 plain radiographic examinations and seven MR imagings in 28 cases of OCD in 24 patients. Typical radiologic findings were osteochondral defect with sclerotic rim of variable thickness and osteochondral fragment. Sites of osteochondral defect were medial (35.9%) or lateral (32%) femoral chondyle and medial (7.1%) or lateral (25%) side of talar dome. Sclerotic rim was seen in 24 cases (85%) and osteochondral fragments including nine loose bodies were seen in 21 cases (75%). The size of osteochondral defect with unstable fragment (average 2.05 cm) and loose body (2.04 cm) in the knee joint were similar to, but statistically larger than that with stable fragment (1.35 cm). All osteochondral defects were well visualized on MR images. Abnormalities of articular cartilage and effusion in the interface between the parent bone and fragment were seen in five cases of which there were confirmed three unstable cases arthroscopically. We concluded that size of defect may be a good parameter for predicting mechanical stability and MRI may be useful in the diagnosis of OCD and determining the methods of treatment.
Microsphere-based gradient implants for osteochondral regeneration: a long-term study in sheep
Mohan, Neethu; Gupta, Vineet; Sridharan, Banu Priya; Mellott, Adam J; Easley, Jeremiah T; Palmer, Ross H; Galbraith, Richard A; Key, Vincent H; Berkland, Cory J; Detamore, Michael S
2015-01-01
Background: The microfracture technique for cartilage repair has limited ability to regenerate hyaline cartilage. Aim: The current study made a direct comparison between microfracture and an osteochondral approach with microsphere-based gradient plugs. Materials & methods: The PLGA-based scaffolds had opposing gradients of chondroitin sulfate and β-tricalcium phosphate. A 1-year repair study in sheep was conducted. Results: The repair tissues in the microfracture were mostly fibrous and had scattered fissures with degenerative changes. Cartilage regenerated with the gradient plugs had equal or superior mechanical properties; had lacunated cells and stable matrix as in hyaline cartilage. Conclusion: This first report of gradient scaffolds in a long-term, large animal, osteochondral defect demonstrated potential for equal or better cartilage repair than microfracture. PMID:26418471
Gradient nano-engineered in situ forming composite hydrogel for osteochondral regeneration.
Radhakrishnan, Janani; Manigandan, Amrutha; Chinnaswamy, Prabu; Subramanian, Anuradha; Sethuraman, Swaminathan
2018-04-01
Fabrication of anisotropic osteochondral-mimetic scaffold with mineralized subchondral zone and gradient interface remains challenging. We have developed an injectable semi-interpenetrating network hydrogel construct with chondroitin sulfate nanoparticles (ChS-NPs) and nanohydroxyapatite (nHA) (∼30-90 nm) in chondral and subchondral hydrogel zones respectively. Mineralized subchondral hydrogel exhibited significantly higher osteoblast proliferation and alkaline phosphatase activity (p gradient interface of nHA and ChS-NPs. Microcomputed tomography (μCT) demonstrated nHA gradation while rheology showed predominant elastic modulus (∼930 Pa) at the interface. Co-culture of osteoblasts and chondrocytes in gradient hydrogels showed layer-specific retention of cells and cell-cell interaction at the interface. In vivo osteochondral regeneration by biphasic (nHA or ChS) and gradient (nHA + ChS) hydrogels was compared with control using rabbit osteochondral defect after 3 and 8 weeks. Complete closure of defect was observed in gradient (8 weeks) while defect remained in other groups. Histology demonstrated collagen and glycosaminoglycan deposition in neo-matrix and presence of hyaline cartilage-characteristic matrix, chondrocytes and osteoblasts. μCT showed mineralized neo-tissue formation, which was confined within the defect with higher bone mineral density in gradient (chondral: 0.42 ± 0.07 g/cc, osteal: 0.64 ± 0.08 g/cc) group. Further, biomechanical push-out studies showed significantly higher load for gradient group (378 ± 56 N) compared to others. Thus, the developed nano-engineered gradient hydrogel enhanced hyaline cartilage regeneration with subchondral bone formation and lateral host-tissue integration. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fukui, Takaaki; Kitamura, Nobuto; Kurokawa, Takayuki; Yokota, Masashi; Kondo, Eiji; Gong, Jian Ping; Yasuda, Kazunori
2014-04-01
Implantation of PAMPS/PDMAAm double-network (DN) gel can induce hyaline cartilage regeneration in the osteochondral defect. However, it is a problem that the volume of the regenerated cartilage tissue is gradually reduced at 12 weeks. This study investigated whether intra-articular administration of hyaluronic acid (HA) increases the volume of the cartilage regenerated with the DN gel at 12 weeks. A total of 48 rabbits were used in this study. A cylindrical osteochondral defect created in the bilateral femoral trochlea was treated with DN gel (Group DN) or left without any implantation (Group C). In both Groups, we injected 1.0 mL of HA in the left knee, and 1.0 mL of saline solution in the right knee. Quantitative histological evaluations were performed at 2, 4, and 12 weeks, and PCR analysis was performed at 2 and 4 weeks after surgery. In Group DN, the proteoglycan-rich area was significantly greater in the HA-injected knees than in the saline-injected knees at 12 weeks (P = 0.0247), and expression of type 2 collagen, aggrecan, and Sox9 mRNAs was significantly greater in the HA-injected knees than in the saline-injected knees at 2 weeks (P = 0.0475, P = 0.0257, P = 0.0222, respectively). The intra-articular administration of HA significantly enhanced these gene expression at 2 weeks and significantly increased the volume of the hyaline cartilage regenerated by implantation of a DN gel at 12 weeks. This information is important to develop an additional method to increase the volume of the hyaline cartilage tissue in a potential cartilage regeneration strategy using the DN gel.
History of osteochondral allograft transplantation.
Nikolaou, V S; Giannoudis, P V
2017-07-01
Osteochondral defects or injuries represent the most challenging entities to treat, especially when occur to young and active patients. For centuries, it has been recognized that such defects are almost impossible to treat. However, surgeons have never stopped the effort to develop reliable methods to restore articular cartilage and salvage the endangered joint function. Osteochondral allograft transplantation in human was first introduced by Eric Lexer in 1908. Since that era, several pioneers have been worked in the field of osteochondral allotransplantation, presenting and developing the basic research, the methodology and the surgical techniques. Herein we present in brief, the history and the early clinical results of osteochondral allograft transplantation in human. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kon, Elizaveta; Filardo, Giuseppe; Brittberg, Mats; Busacca, Maurizio; Condello, Vincenzo; Engebretsen, Lars; Marlovits, Stefan; Niemeyer, Philipp; Platzer, Patrik; Posthumus, Michael; Verdonk, Peter; Verdonk, Renè; Victor, Jan; van der Merwe, Willem; Widuchowski, Wojciech; Zorzi, Claudio; Marcacci, Maurilio
2017-09-14
study highlighted the safety and potential of a biomimetic implant. While no statistically significant differences were found compared to BMS for chondral lesions, this procedure can be considered a suitable option for the treatment of osteochondral lesions. I.
Yokota, Masashi; Yasuda, Kazunori; Kitamura, Nobuto; Arakaki, Kazunobu; Onodera, Shin; Kurokawa, Takayuki; Gong, Jian-Ping
2011-02-22
Functional repair of articular osteochondral defects remains a major challenge not only in the field of knee surgery but also in tissue regeneration medicine. The purpose is to clarify whether the spontaneous hyaline cartilage regeneration can be induced in a large osteochondral defect created in the femoral condyle by means of implanting a novel double-network (DN) gel at the bottom of the defect. Twenty-five mature rabbits were used in this study. In the bilateral knees of each animal, we created an osteochondral defect having a diameter of 2.4-mm in the medial condyle. Then, in 21 rabbits, we implanted a DN gel plug into a right knee defect so that a vacant space of 1.5-mm depth (in Group I), 2.5-mm depth (in Group II), or 3.5-mm depth (in Group III) was left. In the left knee, we did not apply any treatment to the defect to obtain the control data. All the rabbits were sacrificed at 4 weeks, and the gross and histological evaluations were performed. The remaining 4 rabbits underwent the same treatment as used in Group II, and real-time PCR analysis was performed at 4 weeks. The defect in Group II was filled with a sufficient volume of the hyaline cartilage tissue rich in proteoglycan and type-2 collagen. The Wayne's gross appearance and histology scores showed that Group II was significantly greater than Group I, III, and Control (p hyaline cartilage regeneration can be induced in vivo in an osteochondral defect created in the femoral condyle by means of implanting the DN gel plug at the bottom of the defect so that an approximately 2-mm deep vacant space was intentionally left in the defect. This fact has prompted us to propose an innovative strategy without cell culture to repair osteochondral lesions in the femoral condyle.
Directory of Open Access Journals (Sweden)
Giorgio Lombardo
2015-01-01
Full Text Available Peri-implantitis is characterized by inflammation and crestal bone loss in the tissues surrounding implants. Contamination by deleterious bacteria in the peri-implant microenvironment is believed to be a major factor in the etiology of peri-implantitis. Prior to any therapeutic regenerative treatment, adequate decontamination of the peri-implant microenvironment must occur. Herein we present a novel approach to the treatment of peri-implantitis that incorporates the use of a topical desiccant (HYBENX, along with air powder abrasives as a means of decontamination, followed by the application of biphasic calcium sulfate combined with inorganic bovine bone material to augment the intrabony defect. We highlight the case of a 62-year-old man presenting peri-implantitis at two neighboring implants in positions 12 and 13, who underwent access flap surgery, followed by our procedure. After an uneventful 2-year healing period, both implants showed an absence of bleeding on probing, near complete regeneration of the missing bone, probing pocket depth reduction, and clinical attachment gain. While we observed a slight mucosal recession, there was no reduction in keratinized tissue. Based on the results described within, we conclude that the use of HYBENX and air powder abrasives, followed by bone defect grafting, represents a viable option in the treatment of peri-implantitis.
Holland, T.A.; Bodde, E.W.H.; Baggett, L.S.; Tabata, Y.; Mikos, A.G.; Jansen, J.A.
2005-01-01
In this study, hydrogel scaffolds, based on the polymer oligo(poly(ethylene glycol) fumarate) (OPF), were implanted into osteochondral defects in the rabbit model. Scaffolds consisted of two layers-a bottom, bone forming layer and a top, cartilage forming layer. Three scaffold formulations were
Matsuda, Hidetoshi; Kitamura, Nobuto; Kurokawa, Takayuki; Arakaki, Kazunobu; Gong, Jian Ping; Kanaya, Fuminori; Yasuda, Kazunori
2013-01-31
A double-network (DN) gel, which is composed of poly(2-acrylamido-2-methylpropanesulfonic acid) and poly(N,N'-dimethyl acrylamide), can induce hyaline cartilage regeneration in vivo in a large osteochondral defect. The purpose of this study was to clarify the influence of the thickness of the implanted DN gel on the induction ability of hyaline cartilage regeneration. Thirty-eight mature rabbits were used in this study. We created an osteochondral defect having a diameter of 4.3-mm in the patellofemoral joint. The knees were randomly divided into 4 groups (Group I: 0.5-mm thick gel, Group II: 1.0-mm thick gel, Group III: 5.0-mm thick gel, and Group IV: untreated control). Animals in each group were further divided into 3 sub-groups depending on the gel implant position (2.0-, 3.0-, or 4.0-mm depth from the articular surface) in the defect. The regenerated tissues were evaluated with the Wayne's gross and histological grading scales and real time PCR analysis of the cartilage marker genes at 4 weeks. According to the total Wayne's score, when the depth of the final vacant space was set at 2.0 mm, the scores in Groups I, II, and III were significantly greater than that Group IV (phyaline cartilage regeneration as the 5.0-mm thick DN gel plug. However, the induction ability of the 0.5-mm thick sheet was significantly lower when compared with the 1.0-mm thick gel sheet. The 1.0-mm DN gel sheet is a promising device to establish a cell-free cartilage regeneration strategy that minimizes bone loss from the gel implantation.
Madry, Henning; Kaul, Gunter; Zurakowski, David; Vunjak-Novakovic, Gordana; Cucchiarini, Magali
2015-01-01
Tissue engineering combined with gene therapy is a promising approach for promoting articular cartilage repair. Here, we tested the hypothesis that engineered cartilage with chondrocytes over expressing a human insulin-like growth factor I (IGF-I) gene can enhance the repair of osteochondral defects, in a manner dependent on the duration of cultivation. Genetically modified chondrocytes were cultured on biodegradable polyglycolic acid scaffolds in dynamic flow rotating bioreactors for either 10 or 28 d. The resulting cartilaginous constructs were implanted into osteochondral defects in rabbit knee joints. After 28 weeks of in vivo implantation, immunoreactivity to ß-gal was detectable in the repair tissue of defects that received lacZ constructs. Engineered cartilaginous constructs based on IGF-I-over expressing chondrocytes markedly improved osteochondral repair compared with control (lacZ) constructs. Moreover, IGF-I constructs cultivated for 28 d in vitro significantly promoted osteochondral repair vis-à-vis similar constructs cultivated for 10 d, leading to significantly decreased osteoarthritic changes in the cartilage adjacent to the defects. Hence, the combination of spatially defined overexpression of human IGF-I within a tissue-engineered construct and prolonged bioreactor cultivation resulted in most enhanced articular cartilage repair and reduction of osteoarthritic changes in the cartilage adjacent to the defect. Such genetically enhanced tissue engineering provides a versatile tool to evaluate potential therapeutic genes in vivo and to improve our comprehension of the development of the repair tissue within articular cartilage defects. Insights gained with additional exploration using this model may lead to more effective treatment options for acute cartilage defects. PMID:23588785
Directory of Open Access Journals (Sweden)
H Madry
2013-04-01
Full Text Available Tissue engineering combined with gene therapy is a promising approach for promoting articular cartilage repair. Here, we tested the hypothesis that engineered cartilage with chondrocytes overexpressing a human insulin-like growth factor I (IGF-I gene can enhance the repair of osteochondral defects, in a manner dependent on the duration of cultivation. Genetically modified chondrocytes were cultured on biodegradable polyglycolic acid scaffolds in dynamic flow rotating bioreactors for either 10 or 28 d. The resulting cartilaginous constructs were implanted into osteochondral defects in rabbit knee joints. After 28 weeks of in vivo implantation, immunoreactivity to ß-gal was detectable in the repair tissue of defects that received lacZ constructs. Engineered cartilaginous constructs based on IGF-I-overexpressing chondrocytes markedly improved osteochondral repair compared with control (lacZ constructs. Moreover, IGF-I constructs cultivated for 28 d in vitro significantly promoted osteochondral repair vis-à-vis similar constructs cultivated for 10 d, leading to significantly decreased osteoarthritic changes in the cartilage adjacent to the defects. Hence, the combination of spatially defined overexpression of human IGF-I within a tissue-engineered construct and prolonged bioreactor cultivation resulted in most enhanced articular cartilage repair and reduction of osteoarthritic changes in the cartilage adjacent to the defect. Such genetically enhanced tissue engineering provides a versatile tool to evaluate potential therapeutic genes in vivo and to improve our comprehension of the development of the repair tissue within articular cartilage defects. Insights gained with additional exploration using this model may lead to more effective treatment options for acute cartilage defects.
Energy Technology Data Exchange (ETDEWEB)
Sartori, M. [Laboratory of Biocompatibility, Technological Innovations and Advanced Therapies, Rizzoli Orthopedic Institute, Bologna (Italy); Pagani, S., E-mail: stefania.pagani@ior.it [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Bologna (Italy); Ferrari, A. [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Bologna (Italy); Department of Medical and Surgical Sciences (DIMEC), University of Bologna, Bologna (Italy); Costa, V.; Carina, V. [Innovative Technology Platform for Tissue Engineering, Theranostic and Oncology, Rizzoli Orthopedic Institute, Palermo (Italy); Figallo, E. [Fin-Ceramica Faenza SpA, Faenza, Ravenna (Italy); Maltarello, M.C. [Laboratory of Musculoskeletal Cell Biology, Rizzoli Orthopedic Institute, Bologna (Italy); Martini, L.; Fini, M. [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Bologna (Italy); Giavaresi, G. [Innovative Technology Platform for Tissue Engineering, Theranostic and Oncology, Rizzoli Orthopedic Institute, Palermo (Italy)
2017-01-01
Current treatments for acute or degenerative chondral and osteochondral lesions are in need of improvement, as these types of injuries lead to disability and worsen the quality of life in a high percentage of patients. The aim of this study was to develop a new bi-layered scaffold for osteochondral tissue regeneration through a “biomimetic” and “bioinspired” approach. For chondral regeneration, the scaffold was realized with an organic compound (type I collagen), while for the regeneration of the subchondral layer, bioactive magnesium-doped hydroxyapatite (Mg/HA) crystals were co-precipitated with the organic component of the scaffold. The entire scaffold structure was stabilized with a cross-linking agent, highly reactive bis-epoxyde (1,4-butanediol diglycidyl ether – BDDGE 1 wt%). The developed scaffold was then characterized for its physico-chemical characteristics. Its structure and adhesion strength between the integrated layers were investigated. At the same time, in vitro cell culture studies were carried out to examine the ability of chondral and bone scaffold layers to separately support adhesion, proliferation and differentiation of human mesenchymal stem cells (hMSCs) into chondrocytes and osteoblasts, respectively. Moreover, an in vivo study with nude mice, transplanted with osteochondral scaffolds plain or engineered with undifferentiated hMSCs, was also set up with 4 and 8-week time points. The results showed that chondral and bone scaffold layers represented biocompatible scaffolds able to sustain hMSCs attachment and proliferation. Moreover, the association of scaffold stimuli and differentiation medium, induced hMSCs chondrogenic and osteogenic differentiation and deposition of extracellular matrix (ECM). The ectopic implantation of the engineered osteochondral scaffolds indicated that hMSCs were able to colonize the osteochondral scaffold in depth. The scaffold appeared permissive to tissue growth and penetration, ensuring the diffusion
A Hydrogel Model Incorporating 3D-Plotted Hydroxyapatite for Osteochondral Tissue Engineering
Directory of Open Access Journals (Sweden)
Michal Bartnikowski
2016-04-01
Full Text Available The concept of biphasic or multi-layered compound scaffolds has been explored within numerous studies in the context of cartilage and osteochondral regeneration. To date, no system has been identified that stands out in terms of superior chondrogenesis, osteogenesis or the formation of a zone of calcified cartilage (ZCC. Herein we present a 3D plotted scaffold, comprising an alginate and hydroxyapatite paste, cast within a photocrosslinkable hydrogel made of gelatin methacrylamide (GelMA, or GelMA with hyaluronic acid methacrylate (HAMA. We hypothesized that this combination of 3D plotting and hydrogel crosslinking would form a high fidelity, cell supporting structure that would allow localization of hydroxyapatite to the deepest regions of the structure whilst taking advantage of hydrogel photocrosslinking. We assessed this preliminary design in terms of chondrogenesis in culture with human articular chondrocytes, and verified whether the inclusion of hydroxyapatite in the form presented had any influence on the formation of the ZCC. Whilst the inclusion of HAMA resulted in a better chondrogenic outcome, the effect of HAP was limited. We overall demonstrated that formation of such compound structures is possible, providing a foundation for future work. The development of cohesive biphasic systems is highly relevant for current and future cartilage tissue engineering.
Directory of Open Access Journals (Sweden)
Mike Barbeck
2017-12-01
Altogether, the results showed that the addition of G5 enables to reduce scaffold weight loss and to increase mechanical strength. Furthermore, the addition of G5 lead to a higher vascularization of the implant bed required as basis for bone tissue regeneration mediated by higher numbers of BMGCs, while within the PLA parts a significantly lower vascularization was found optimally for chondral regeneration. Thus, this data show that the analyzed bi-layered scaffold may serve as an ideal basis for the regeneration of osteochondral tissue defects. Additionally, the results show that it might be able to reduce the number of experimental animals required as it may be possible to analyze the tissue response to more than one implant in one experimental animal.
Directory of Open Access Journals (Sweden)
Matsuda Hidetoshi
2013-01-01
Full Text Available Abstract Background A double-network (DN gel, which is composed of poly(2-acrylamido-2-methylpropanesulfonic acid and poly(N,N’-dimethyl acrylamide, can induce hyaline cartilage regeneration in vivo in a large osteochondral defect. The purpose of this study was to clarify the influence of the thickness of the implanted DN gel on the induction ability of hyaline cartilage regeneration. Methods Thirty-eight mature rabbits were used in this study. We created an osteochondral defect having a diameter of 4.3-mm in the patellofemoral joint. The knees were randomly divided into 4 groups (Group I: 0.5-mm thick gel, Group II: 1.0-mm thick gel, Group III: 5.0-mm thick gel, and Group IV: untreated control. Animals in each group were further divided into 3 sub-groups depending on the gel implant position (2.0-, 3.0-, or 4.0-mm depth from the articular surface in the defect. The regenerated tissues were evaluated with the Wayne’s gross and histological grading scales and real time PCR analysis of the cartilage marker genes at 4 weeks. Results According to the total Wayne’s score, when the depth of the final vacant space was set at 2.0 mm, the scores in Groups I, II, and III were significantly greater than that Group IV (p Conclusions The 1.0-mm thick DN gel sheet had the same ability to induce hyaline cartilage regeneration as the 5.0-mm thick DN gel plug. However, the induction ability of the 0.5-mm thick sheet was significantly lower when compared with the 1.0-mm thick gel sheet. The 1.0-mm DN gel sheet is a promising device to establish a cell-free cartilage regeneration strategy that minimizes bone loss from the gel implantation.
... can then break loose, causing pain and possibly hinder joint motion. Osteochondritis dissecans occurs most often in ... Adolescents participating in organized sports might benefit from education on the risks to their joints associated with ...
Hyaline cartilage degenerates after autologous osteochondral transplantation.
Tibesku, C O; Szuwart, T; Kleffner, T O; Schlegel, P M; Jahn, U R; Van Aken, H; Fuchs, S
2004-11-01
Autologous osteochondral grafting is a well-established clinical procedure to treat focal cartilage defects in patients, although basic research on this topic remains sparse. The aim of the current study was to evaluate (1) histological changes of transplanted hyaline cartilage of osteochondral grafts and (2) the tissue that connects the transplanted cartilage with the adjacent cartilage in a sheep model. Both knee joints of four sheep were opened surgically and osteochondral grafts were harvested and simultaneously transplanted to the contralateral femoral condyle. The animals were sacrificed after three months and the received knee joints were evaluated histologically. Histological evaluation showed a complete ingrowth of the osseous part of the osteochondral grafts. A healing or ingrowth at the level of the cartilage could not be observed. Histological evaluation of the transplanted grafts according to Mankin revealed significantly more and more severe signs of degeneration than the adjacent cartilage, such as cloning of chondrocytes and irregularities of the articular surface. We found no connecting tissue between the transplanted and the adjacent cartilage and histological signs of degeneration of the transplanted hyaline cartilage. In the light of these findings, long-term results of autologous osteochondral grafts in human beings have to be followed critically.
Treatment of osteochondral defects of the talus
van Bergen, C. J. A.; de Leeuw, P. A. J.; van Dijk, C. N.
2008-01-01
This review article provides a current concepts overview of osteochondral defects of the talus, with special emphasis on treatment options, their indications and future developments. Osteochondral defects of the talar dome are mostly caused by a traumatic event. They may lead to deep ankle pain on
Visser, J.
2015-01-01
Implants were biofabricated for the repair of chondral and osteochondral articular joint defects. The implants were based on gelatin methacrylamide (GelMA) hydrogels combined with printed fibers from polycaprolactone (PCL) for mechanical reinforcement. In Part I of the thesis, biological
Directory of Open Access Journals (Sweden)
Yang Pei
2014-01-01
Full Text Available To investigate the reparative efficacy of tissue-engineered osteochondral (TEO graft for repairing the osteochondral defect in goat, we designed a double-chamber stirring bioreactor to construct the bone and cartilage composites simultaneously in one β-TCP scaffold and observed the reparative effect in vivo. The osteochondral defects were created in goats and all the animals were divided into 3 groups randomly. In groups A, the defect was treated with the TEO which was cultured with mechanical stimulation of stir; in group B, the defect was treated with TEO which was cultured without mechanical stimulation of stir; in groups C, the defect was treated without TEO. At 12 weeks and 24 weeks after operation, the reparative effects in different groups were assessed and compared. The results indicated that the reparative effect of the TEO cultured in the bioreactor was better than the control group, and mechanical stimulation of stir could further improve the reparative effect. We provided a feasible and effective method to construct the TEO for treatment of osteochondral defect using autologous BMSCs and the double-chamber bioreactor.
Customized Fabrication of Osteochondral Tissue for Articular Joint Surface Repair
2016-09-01
AWARD NUMBER: W81XWH-14-1-0217 TITLE: Customized Fabrication of Osteochondral Tissue for Articular Joint Surface Repair PRINCIPAL INVESTIGATOR...4. TITLE AND SUBTITLE Customized Fabrication of Osteochondral Tissue for Articular Joint Surface Repair 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH...applicability of these novel osteochondral tissues for articular cartilage repair in rabbit model, using medical imaging-guided PSL. Such an approach may
Osteochondral injuries of the foot and ankle.
Frost, Andrew; Roach, Richard
2009-06-01
Osteochondral injuries commonly affect the ankle joint and involve the dome of the talus. This article describes the etiology and pathogenesis of these injuries. Their clinical presentation is described and advice is given on how to diagnose and investigate suspected osteochondral injuries. The various treatment options currently available are briefly reviewed. There is some attempt made to give consensus on optimal treatment of this condition at the present time.
Neglected, semimembranosus osteochondral avulsion fracture of the posteromedial tibial plateau
Directory of Open Access Journals (Sweden)
Rakesh John
2018-06-01
Full Text Available Semimembranosus avulsion fracture is infrequently reported and is easy to miss on plain radiographs; the mechanism of injury is highly controversial. Initial reports linked it to anterior cruciate ligament and medial meniscal tears. We report an osteochondral semimembranosus avulsion fracture of the posteromedial tibial plateau with associated posterior cruciate ligament rupture. Also described is a novel surgical fixation technique for such osteochondral fractures where the surgical exposure is limited due to the obliquity of the fracture line resulting in a greater involvement of the articular cartilage than the small bony component. The fixation technique described may be used for osteochondral fractures where the application of a conventional compression screw may not be feasible. Keywords: Osteochondral fracture, Semimembranosus avulsion fracture, Posteromedial tibial plateau, Neglected, Nonunion
Osteochondral lesion of the bilateral femoral heads in a young athletic patient
Energy Technology Data Exchange (ETDEWEB)
Lee, Jung Eun; Ryu, Kyung Nam; Park, Ji Seon; Cho, Yoon Je [Kyung Hee University Hospital, Seoul (Korea, Republic of); Yoon, So Hee; Park, So Young; Jin, Wook [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Seoul (Korea, Republic of); Lee, Kyung Ryeol [Dept. of Radiology, Jeju National University Hospital, Jeju (Korea, Republic of)
2014-12-15
Osteochondral lesions of the femoral head are uncommon and few studies have reported their imaging findings. Since joints are at risk of early degeneration after osteochondral damage, timely recognition is important. Osteochondral lesions of femoral head may often be necessary to differentiate from avascular necrosis. Here, we report a case of osteochondral lesions on bilateral femoral heads. This lesion manifested as subchondral cysts in initial radiographs, which led to further evaluation by computed tomography arthrography and magnetic resonance imaging, which revealed overlying cartilage defects.
Bone compaction enhances fixation of weightbearing titanium implants
DEFF Research Database (Denmark)
Kold, Søren; Rahbek, Ole; Vestermark, Marianne
2005-01-01
are weightbearing, the effects of compaction on weightbearing implants were examined. The hypothesis was that compaction would increase implant fixation compared with conventional drilling. Porous-coated titanium implants were inserted bilaterally into the weightbearing portion of the femoral condyles of dogs....... In each dog, one knee had the implant cavity prepared with drilling, and the other knee was prepared with compaction. Eight dogs were euthanized after 2 weeks, and eight dogs were euthanized after 4 weeks. Femoral condyles from an additional eight dogs represented Time 0. Compacted specimens had higher...... bone-implant contact and periimplant bone density at 0 and 2 weeks, but not at 4 weeks. A biphasic response of compaction was found with a pushout test, as compaction increased ultimate shear strength and energy absorption at 0 and 4 weeks, but not at 2 weeks. This biphasic response indicates...
Directory of Open Access Journals (Sweden)
Kazem Marzban
2017-02-01
Full Text Available Objective(s: CaO–MgO–SiO2 system bioceramics possess good characteristics for hard tissue engineering applications. The aim of the study was to synthesize the nano powder by using a sol-gel method and evaluate of bioactivity in the cells culture. Methods: To characterize of powder X-ray diffraction (XRD, transmission electron microscopy (TEM and to evaluate the bioactivity sample cell seeding and methylthiazol tetrazolium (MTT assay were performed. Results: X-ray diffraction (XRD analysis showed that the biphasic powder was obtained at 1300°C for 2 h by using a sol-gel method. Transmission electron microscopy (TEM image showed that powder particle size was about 45 nm. Besides, cell culture results indicated that the percentage of viability values was increased by the extension of period. Conclusions: found that the sample is cytocompatible and has cell proliferation potential in culture medium. The present study demonstrates that, the biphasic CaO–MgO–SiO2 system can be used to achieve novel bioactive materials for bone implant application.
High-resolution MR imaging of talar osteochondral lesions with new classification
Energy Technology Data Exchange (ETDEWEB)
Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Shatin, NT (China); Wong, Margaret Wan Nar [Prince of Wales Hospital, Chinese University of Hong Kong, Department of Orthopaedics and Traumatology, Shatin (China)
2012-04-15
Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)
High-resolution MR imaging of talar osteochondral lesions with new classification
International Nuclear Information System (INIS)
Griffith, James Francis; Lau, Domily Ting Yi; Yeung, David Ka Wai; Wong, Margaret Wan Nar
2012-01-01
Retrospective review of high-resolution MR imaging features of talar dome osteochondral lesions and development of new classification system based on these features. Over the past 7 years, 70 osteochondral lesions of the talar dome from 70 patients (49 males, 21 females, mean age 42 years, range 15-62 years) underwent high-resolution MR imaging with a microscopy coil at 1.5 T. Sixty-one (87%) of 70 lesions were located on the medial central aspect and ten (13%) lesions were located on the lateral central aspect of the talar dome. Features evaluated included cartilage fracture, osteochondral junction separation, subchondral bone collapse, bone:bone separation, and marrow change. Based on these findings, a new five-part grading system was developed. Signal-to-noise characteristics of microscopy coil imaging at 1.5 T were compared to dedicated ankle coil imaging at 3 T. Microscopy coil imaging at 1.5 T yielded 20% better signal-to-noise characteristics than ankle coil imaging at 3 T. High-resolution MR revealed that osteochondral junction separation, due to focal collapse of the subchondral bone, was a common feature, being present in 28 (45%) of 61 medial central osteochondral lesions. Reparative cartilage hypertrophy and bone:bone separation in the absence of cartilage fracture were also common findings. Complete osteochondral separation was uncommon. A new five-part grading system incorporating features revealed by high-resolution MR imaging was developed. High-resolution MRI reveals clinically pertinent features of talar osteochondral lesions, which should help comprehension of symptomatology and enhance clinical decision-making. These features were incorporated in a new MR-based grading system. Whenever possible, symptomatic talar osteochondral lesions should be assessed by high-resolution MR imaging. (orig.)
Cell-laden hydrogels for osteochondral and cartilage tissue engineering.
Yang, Jingzhou; Zhang, Yu Shrike; Yue, Kan; Khademhosseini, Ali
2017-07-15
Despite tremendous advances in the field of regenerative medicine, it still remains challenging to repair the osteochondral interface and full-thickness articular cartilage defects. This inefficiency largely originates from the lack of appropriate tissue-engineered artificial matrices that can replace the damaged regions and promote tissue regeneration. Hydrogels are emerging as a promising class of biomaterials for both soft and hard tissue regeneration. Many critical properties of hydrogels, such as mechanical stiffness, elasticity, water content, bioactivity, and degradation, can be rationally designed and conveniently tuned by proper selection of the material and chemistry. Particularly, advances in the development of cell-laden hydrogels have opened up new possibilities for cell therapy. In this article, we describe the problems encountered in this field and review recent progress in designing cell-hydrogel hybrid constructs for promoting the reestablishment of osteochondral/cartilage tissues. Our focus centers on the effects of hydrogel type, cell type, and growth factor delivery on achieving efficient chondrogenesis and osteogenesis. We give our perspective on developing next-generation matrices with improved physical and biological properties for osteochondral/cartilage tissue engineering. We also highlight recent advances in biomanufacturing technologies (e.g. molding, bioprinting, and assembly) for fabrication of hydrogel-based osteochondral and cartilage constructs with complex compositions and microarchitectures to mimic their native counterparts. Despite tremendous advances in the field of regenerative medicine, it still remains challenging to repair the osteochondral interface and full-thickness articular cartilage defects. This inefficiency largely originates from the lack of appropriate tissue-engineered biomaterials that replace the damaged regions and promote tissue regeneration. Cell-laden hydrogel systems have emerged as a promising tissue
Calder, James D F; Ballal, Moez S; Deol, Rupinderbir S; Pearce, Christopher J; Hamilton, Paul; Lutz, Michael
2015-09-01
Osteochondral Autologous Transplant (OATs) as a treatment option for Osteochondral lesions (OCLs) of the talar dome frequently uses the distal femur as the donor site which is associated with donor site morbidity in up to 50%. Some studies have described the presence of hyaline cartilage in the posterior superior calcaneal tuberosity. The aim of this study was to evaluate the posterior superior calcaneal tuberosity to determine if it can be a suitable donor site for OATs of the talus In this cadaveric study, we histologically evaluated 12 osteochondral plugs taken from the posterior superior calcaneal tuberosity and compared them to 12 osteochondral plugs taken from the talar dome. In the talar dome group, all samples had evidence of hyaline cartilage with varying degrees of GAG staining. The average hyaline cartilage thickness in the samples was 1.33 mm. There was no evidence of fibrocartilage, fibrous tissue or fatty tissue in this group. In contrast, the Calcaneal tuberosity samples had no evidence of hyaline cartilage. Fibrocartilage was noted in 3 samples only. We believe that the structural differences between the talus and calcanium grafts render the posterior superior clancaneal tuberosity an unsuitable donor site for OATs in the treatment of OCL of the talus. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Li, Xiang; Li, Yubao; Zuo, Yi; Qu, Dan; Liu, Yiming; Chen, Tao; Jiang, Nan; Li, Hui; Li, Jihua
2015-10-01
A novel bi-layered osteochondral scaffold, including of PVA/Gel/V layer for the cartilage and n-HA/PA6 layer for the subchondral bone, has been proposed to evaluate the potential of the engineered of osteochondral grafts in repairing articular osteochondral defects in rabbits. The two different layers of the scaffolds were seeded with allogenic bone marrow-derived stem cells (BMSCs), which were chondrogenically and osteogenically induced respectively. The critical-size osteochondral defects were created in the knees of adult rabbits. The defects were treated with cell-bi-layered constructs (Group A), bi-layered constructs (Group B) and untreated group C as control group. The adhesion, proliferation and differentiation of BMSCs were demonstrated by immunohistochemical staining and scanning electron microscopy (SEM) in vitro. Cell survival was tracked via fluorescent labeling in vivo. Overall, the porous PVA/Gel/V-n-HA/PA6 scaffold was compatible and had no negative effects on the BMSCs in vitro culture. The cell-bi-layered scaffolds showed superior repair results as compared to the control group using gross examination and histological assessment. With BMSCs implantation, the two different layers of the composite biomimetic scaffolds provided a suitable environment for cells to form respective tissue. Simultaneously, the RT-PCR results confirmed the expression of specific extracellular matrix (ECM) markers for cartilaginous or osteoid tissue. This investigation showed that the porous PVA/Gel/V-n-HA/PA6 scaffold is a potential matrix for treatment of osteochondral defects, and the method of using chondrogenically and osteogenically differentiated BMSCs as seed cells on each layer might be a promising strategy in repair of articular osteochondral defect due to enhanced chondrogenesis and osteogenesis. © 2015 Wiley Periodicals, Inc.
Directory of Open Access Journals (Sweden)
F. Tessarolo
2011-01-01
Full Text Available Matrix-induced sutologous chondrocytes implantation (MACI is a promising technique for the treatment of articular cartilage lesions, but long time outcome have to be established. We developed and optimized specific techniques of histochemical staining to characterize healthy and pathologic osteochondral tissue. Seven different staining protocols were applied to assess tissue architecture, cells morphology, proteoglycan content, and collagen fibers distribution. Potentialities of histochemical staining and histomorphology of biopsies from second look arthroscopy will be presented.
Osteochondral lesions of the humeral trochlea in the young athlete
Energy Technology Data Exchange (ETDEWEB)
Marshall, Kelley W. [Pediatric Radiology of America, Roanoke, VA (United States); Children' s Healthcare of Atlanta at Scottish Rite, Atlanta, GA (United States); Children' s Diagnostic Imaging of Atlanta, P.C., Marietta, GA (United States); Marshall, David L.; Busch, Michael T. [Children' s Orthopaedics of Atlanta, P.C., Atlanta, GA (United States); Children' s Healthcare of Atlanta at Scottish Rite, Atlanta, GA (United States); Williams, Joseph P. [Children' s Healthcare of Atlanta at Scottish Rite, Atlanta, GA (United States); Children' s Diagnostic Imaging of Atlanta, P.C., Marietta, GA (United States)
2009-05-15
The purpose of this study was to characterize the variety of osteochondral abnormalities of the humeral trochlea in the pediatric athlete. Patients with trochlear abnormalities were identified through keyword search of radiology dictations from 1999 to 2007. The patient's medical record, imaging studies, and surgical reports were reviewed. The osteochondral lesions were categorized based on the imaging appearance. Surgical results were reviewed in conjunction with the imaging findings. Eighteen patients were identified. Trochlear lesions were stratified into two imaging groups: Osteochondral injury/osteochondritis dissecans (OCD) vs. avascular necrosis (AVN). The osteochondral injury group was stratified into medial and lateral trochlear abnormalities. The medial lesions (n=3) were small (<6 mm) and were located on the posterior articular surface of the medial trochlea. The lateral lesions (n=10) were larger (10-14 mm), circumscribed, and were located on the posterior inferior aspect of the lateral trochlea. Trochlear AVN (n=5) affected development of the lateral trochlea (type A) or both the medial and lateral aspects of the trochlea (type B). AVN occurred exclusively in athletes with history of remote distal humeral fracture. Seven of the 18 patients underwent elbow arthroscopy. Surgical findings and treatment regimens are summarized. Trochlear lesions should be considered in throwing athletes presenting with medial elbow pain and flexion contracture/extension block. Medial trochlear osteochondral injuries may result from posteromedial olecranon abutment. Lateral OCD lesions occur in a characteristic vascular watershed zone resulting from the unique blood supply of the trochlea. Trochlear AVN may be unmasked years following treated distal humeral fracture when the athletic demands upon the adolescent elbow increase, revealing the altered growth and biomechanics. (orig.)
Osteochondral lesions of the humeral trochlea in the young athlete
International Nuclear Information System (INIS)
Marshall, Kelley W.; Marshall, David L.; Busch, Michael T.; Williams, Joseph P.
2009-01-01
The purpose of this study was to characterize the variety of osteochondral abnormalities of the humeral trochlea in the pediatric athlete. Patients with trochlear abnormalities were identified through keyword search of radiology dictations from 1999 to 2007. The patient's medical record, imaging studies, and surgical reports were reviewed. The osteochondral lesions were categorized based on the imaging appearance. Surgical results were reviewed in conjunction with the imaging findings. Eighteen patients were identified. Trochlear lesions were stratified into two imaging groups: Osteochondral injury/osteochondritis dissecans (OCD) vs. avascular necrosis (AVN). The osteochondral injury group was stratified into medial and lateral trochlear abnormalities. The medial lesions (n=3) were small (<6 mm) and were located on the posterior articular surface of the medial trochlea. The lateral lesions (n=10) were larger (10-14 mm), circumscribed, and were located on the posterior inferior aspect of the lateral trochlea. Trochlear AVN (n=5) affected development of the lateral trochlea (type A) or both the medial and lateral aspects of the trochlea (type B). AVN occurred exclusively in athletes with history of remote distal humeral fracture. Seven of the 18 patients underwent elbow arthroscopy. Surgical findings and treatment regimens are summarized. Trochlear lesions should be considered in throwing athletes presenting with medial elbow pain and flexion contracture/extension block. Medial trochlear osteochondral injuries may result from posteromedial olecranon abutment. Lateral OCD lesions occur in a characteristic vascular watershed zone resulting from the unique blood supply of the trochlea. Trochlear AVN may be unmasked years following treated distal humeral fracture when the athletic demands upon the adolescent elbow increase, revealing the altered growth and biomechanics. (orig.)
Marchand, Catherine; Chen, Gaoping; Tran-Khanh, Nicolas; Sun, Jun; Chen, Hongmei; Buschmann, Michael D; Hoemann, Caroline D
2012-03-01
controls, chitosan implants solidified with thrombin elicited a more hyaline and structurally integrated osteochondral unit, features needed for long-term durability.
Aurich, M; Albrecht, D; Angele, P; Becher, C; Fickert, S; Fritz, J; Müller, P E; Niemeyer, P; Pietschmann, M; Spahn, G; Walther, M
2017-02-01
(MACT) are recommended. Transplantation of so-called (osteochondral) mega grafts, such as autologous bone grafts or allografts, are used for very large osteochondral defects that cannot be reconstructed otherwise. Implantation of the so-called "small metal implants" - such as HemiCAP Talus® - is reserved for selected cases after failed primary reconstruction. Corrective osteotomies are indicated in accompanying axial malalignments. Conclusions: There are several different treatment strategies for OCLs, but clinical studies are rare and evidence is limited. Therefore, interventional studies, e.g. randomised controlled trials (RCTs), but also observational studies, e.g. based on data of the Cartilage Registry of the German Society of Orthopaedics and Traumatology (www.knorpelregister-dgou.de), are needed and are recommended by the authors. Georg Thieme Verlag KG Stuttgart · New York.
Bugbee, William D.; Pallante-Kichura, Andrea L.; Görtz, Simon; Amiel, David; Sah, Robert
2016-01-01
The treatment of articular cartilage injury and disease has become an increasingly relevant part of orthopaedic care. Articular cartilage transplantation, in the form of osteochondral allografting, is one of the most established techniques for restoration of articular cartilage. Our research efforts over the last two decades have supported the transformation of this procedure from experimental “niche” status to a cornerstone of orthopaedic practice. In this Kappa Delta paper, we describe our translational and clinical science contributions to this transformation: (1) to enhance the ability of tissue banks to process and deliver viable tissue to surgeons and patients, (2) to improve the biological understanding of in vivo cartilage and bone remodeling following osteochondral allograft (OCA) transplantation in an animal model system, (3) to define effective surgical techniques and pitfalls, and (4) to identify and clarify clinical indications and outcomes. The combination of coordinated basic and clinical studies is part of our continuing comprehensive academic OCA transplant program. Taken together, the results have led to the current standards for OCA processing and storage prior to implantation and also novel observations and mechanisms of the biological and clinical behavior of OCA transplants in vivo. Thus, OCA transplantation is now a successful and increasingly available treatment for patients with disabling osteoarticular cartilage pathology. PMID:26234194
Osteochondritis (osteochondrosis) dissecans: A review and new MRI classification
International Nuclear Information System (INIS)
Bohndorf, K.
1998-01-01
Osteochondritis (osteochondrosis) dissecans (OCD) is a common condition in children, adolescents, and young adults. Describing OCD together with osteochondral fractures and epiphyseal ossification disturbances and considering these three conditions as one entity has caused much confusion. Age distribution and localization combined with the radiologic and surgical presentation distinguishes these conditions. Osteochondritis dissecans represents an osseous lesion with secondary involvement of the overlying cartilage. Beginning as avascular osteonecrosis, OCD forms a transitional zone that harbors the potential of restoration with complete healing or progression to an osseous defect. Mechanical and traumatic factors are etiologically dominant in OCD, but a predisposition seems to be a contributing factor in some patients. Osteochondritis dissecans is generally diagnosed by conventional radiology. Its therapy is determined by the stage of the lesion and MRI will become the method of choice for staging. Intact cartilage, contrast enhancement of the lesion, and absent ''cystic'' defects are findings of MRI stage I and justify conservative therapy, obviating arthroscopy. Cartilage defect with or without incomplete separation of the fragment, fluid around an undetached fragment, and a dislodged fragment are MRI findings observed in stage II and require arthroscopy with possible intervention. Thus, MRI can noninvasively separate non-surgical from possibly surgical lesions and should replace diagnostic arthroscopy. (orig.)
Directory of Open Access Journals (Sweden)
Carlos Eduardo Sanches Vaz
2008-01-01
Full Text Available O tratamento da osteocondrite dissecante do joelho com lesão tipo cratera associada a corpo livre intra-articular pode ser realizado pela fixação do fragmento osteocondral no seu local de origem. No entanto, existem controvérsias quanto à indicação e eficácia deste procedimento, principalmente quando o corpo livre está solto por tempo prolongado, já que existem relatos na literatura demonstrando deterioração do revestimento condral do mesmo diretamente relacionado com o intervalo decorrente de sua soltura. Relatamos um caso em que, apesar do fragmento osteocondral estar livre na articulação por aproximadamente cinco semanas, a sua fixação não trouxe complicações e resultou em cicatrização completa da lesão. Nós concluímos que, principalmente nos casos onde a lesão osteocondral no côndilo femoral envolve a superfície de carga, quando então o descarte do fragmento geralmente resultaria em mau prognóstico, as possíveis complicações da fixação tardia são compensadas pelos benefícios obtidos pela redução do fragmento osteocondral no local de origem, resultando na recuperação da congruência articular e possivelmente evitando um processo degenerativo articular precoce.The treatment of dissecting knee osteochondritis with crater-like lesion associated to intra-articular loose body can be provided by fixating the osteochondral fragment on its original site. However, there is some concern about the efficacy of this approach, since some reports have shown that the cartilage layer in osteochondral loose bodies that have been detached for a long time becomes deteriorated. We report a case where while the osteochondral loose body was detached for as long as five weeks, the fixation to the osteochondral defect was uneventful and resulted in a completely healed lesion. We concluded that, especially in cases in which the lesion involves a weight-bearing area of the knee with a detached osteochondral fragment, when the
Directory of Open Access Journals (Sweden)
K.A. Prosolov
2017-09-01
Full Text Available Bioactive calcium phosphate coatings were deposited by radio-frequency magnetron sputtering from biphasic targets of hydroxyapatite and tricalcium phosphate, sintered at different mass % ratios. According to Raman scattering and X-ray diffraction data, the deposited hydroxyapatite coatings have a disordered structure. High-temperature treatment of the coatings in air leads to a transformation of the quasi-amorphous structure into a crystalline one. A correlation has been observed between the increase in the Ca content in the coatings and a subsequent decrease in Ca in the biphasic targets after a series of deposition processes. It was proposed that the addition of tricalcium phosphate to the targets would led to a finer coating's surface topography with the average size of 78 nm for the structural elements.
Repair of articular osteochondral defects of the knee joint using a composite lamellar scaffold.
Lv, Y M; Yu, Q S
2015-04-01
The major problem with repair of an articular cartilage injury is the extensive difference in the structure and function of regenerated, compared with normal cartilage. Our work investigates the feasibility of repairing articular osteochondral defects in the canine knee joint using a composite lamellar scaffold of nano-ß-tricalcium phosphate (ß-TCP)/collagen (col) I and II with bone marrow stromal stem cells (BMSCs) and assesses its biological compatibility. The bone-cartilage scaffold was prepared as a laminated composite, using hydroxyapatite nanoparticles (nano-HAP)/collagen I/copolymer of polylactic acid-hydroxyacetic acid as the bony scaffold, and sodium hyaluronate/poly(lactic-co-glycolic acid) as the cartilaginous scaffold. Ten-to 12-month-old hybrid canines were randomly divided into an experimental group and a control group. BMSCs were obtained from the iliac crest of each animal, and only those of the third generation were used in experiments. An articular osteochondral defect was created in the right knee of dogs in both groups. Those in the experimental group were treated by implanting the composites consisting of the lamellar scaffold of ß-TCP/col I/col II/BMSCs. Those in the control group were left untreated. After 12 weeks of implantation, defects in the experimental group were filled with white semi-translucent tissue, protruding slightly over the peripheral cartilage surface. After 24 weeks, the defect space in the experimental group was filled with new cartilage tissues, finely integrated into surrounding normal cartilage. The lamellar scaffold of ß-TCP/col I/col II was gradually degraded and absorbed, while new cartilage tissue formed. In the control group, the defects were not repaired. This method can be used as a suitable scaffold material for the tissue-engineered repair of articular cartilage defects. Cite this article: Bone Joint Res 2015;4:56-64. ©2015 The British Editorial Society of Bone & Joint Surgery.
Osteochondritis dissecans of the talus treated with the mosaicplasty technique: a case report.
Kodama, Narihito; Honjo, Masasi; Maki, Junichi; Hukuda, Sinsuke
2004-01-01
The authors present the use of osteochondral autografting with mosaicplasty technique performed on a 20-year-old man for a large osteochondral talar dome lesion. The patient had sustained a right ankle sprain many times while playing rugby football. The lesion measured 15 mm in diameter and encompassed more than one-third of the articular surface. After exposing the talus to a medial malleolar osteotomy, 3 osteochondral grafts taken from the medial femoral condyle of the ipsilateral knee were press-fit into the lesion. One year postoperatively, the patient has returned to playing rugby football. Radiographically, there was incorporation of the grafts. The authors believe that the mosaicplasty technique presents a promising new option in the treatment of osteochondritis dissecans of the talus.
Importance of Donor Chondrocyte Viability for Osteochondral Allografts.
Cook, James L; Stannard, James P; Stoker, Aaron M; Bozynski, Chantelle C; Kuroki, Keiichi; Cook, Cristi R; Pfeiffer, Ferris M
2016-05-01
Osteochondral allograft (OCA) transplantation provides a biological treatment option for functional restoration of large articular cartilage defects in multiple joints. While successful outcomes after OCA transplantation have been linked to viable donor chondrocytes, the importance of donor cell viability has not been comprehensively validated. To use a canine model to determine the importance of donor chondrocyte viability at the time of implantation with respect to functional success of femoral condylar OCAs based on radiographic, gross, cell viability, histologic, biochemical, and biomechanical outcome measures. Controlled laboratory study. After approval was obtained from the institutional animal care and use committee, adult female dogs (N = 16) were implanted with 8-mm cylindrical OCAs from male dogs in the lateral and medial femoral condyles of 1 knee. OCAs were preserved for 28 or 60 days after procurement, and chondrocyte viability was quantified before implantation. Two different storage media, temperatures, and time points were used to obtain a spectrum of percentage chondrocyte viability at the time of implantation. A successful outcome was defined as an OCA that was associated with graft integration, maintenance of hyaline cartilage, lack of associated cartilage disorder, and lack of fibrillation, fissuring, or fibrous tissue infiltration of the allograft based on subjective radiographic, gross, and histologic assessments at 6 months after implantation. Chondrocyte viability ranged from 23% to 99% at the time of implantation. All successful grafts had >70% chondrocyte viability at the time of implantation, and no graft with chondrocyte viability <70% was associated with a successful outcome. Live-dead stained sections and histologic findings with respect to cell morphological features suggested that successful grafts were consistently composed of viable chondrocytes in lacunae, while grafts that were not successful were composed of nonviable
Hollenstein, Jérôme; Terrier, Alexandre; Cory, Esther; Chen, Albert C.; Sah, Robert L.; Pioletti, Dominique P.
2016-01-01
The objective of this study was to test the hypothesis that mechanical properties of artificial osteochondral constructs can be improved by a tissue-engineered zone of calcification (teZCC) at the bone–hydrogel interface. Experimental push-off tests were performed on osteochondral constructs with or without a teZCC. In parallel, a numerical model of the osteochondral defect treatment was developed and validated against experimental results. Experimental results showed that the shear strength at the bone–hydrogel interface increased by 100% with the teZCC. Numerical predictions of the osteochondral defect treatment showed that the shear stress at the bone–hydrogel interface was reduced with the teZCC. We conclude that a teZCC in osteochondral constructs can provide two improvements. First, it increases the strength of the bone–hydrogel interface and second, it reduces the stress at this interface. PMID:23706035
Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.
Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O
2009-04-01
Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest
Castro, Nathan J.; O'Brien, Joseph; Zhang, Lijie Grace
2015-08-01
The osteochondral interface of an arthritic joint is notoriously difficult to regenerate due to its extremely poor regenerative capacity and complex stratified architecture. Native osteochondral tissue extracellular matrix is composed of numerous nanoscale organic and inorganic constituents. Although various tissue engineering strategies exist in addressing osteochondral defects, limitations persist with regards to tissue scaffolding which exhibit biomimetic cues at the nano to micro scale. In an effort to address this, the current work focused on 3D printing biomimetic nanocomposite scaffolds for improved osteochondral tissue regeneration. For this purpose, two biologically-inspired nanomaterials have been synthesized consisting of (1) osteoconductive nanocrystalline hydroxyapatite (nHA) (primary inorganic component of bone) and (2) core-shell poly(lactic-co-glycolic) acid (PLGA) nanospheres encapsulated with chondrogenic transforming growth-factor β1 (TGF-β1) for sustained delivery. Then, a novel table-top stereolithography 3D printer and the nano-ink (i.e., nHA + nanosphere + hydrogel) were employed to fabricate a porous and highly interconnected osteochondral scaffold with hierarchical nano-to-micro structure and spatiotemporal bioactive factor gradients. Our results showed that human bone marrow-derived mesenchymal stem cell adhesion, proliferation, and osteochondral differentiation were greatly improved in the biomimetic graded 3D printed osteochondral construct in vitro. The current work served to illustrate the efficacy of the nano-ink and current 3D printing technology for efficient fabrication of a novel nanocomposite hydrogel scaffold. In addition, tissue-specific growth factors illustrated a synergistic effect leading to increased cell adhesion and directed stem cell differentiation.
DEFF Research Database (Denmark)
Schmal, Hagen; Kowal, Justyna M; Kassem, Moustapha
2018-01-01
Known problems of the autologous chondrocyte implantation motivate the search for cellular alternatives. The aim of the study was to test the potential of synovium-derived stem cells (SMSC) to regenerate cartilage using a matrix-associated implantation. In an osteochondral defect model of the med......Known problems of the autologous chondrocyte implantation motivate the search for cellular alternatives. The aim of the study was to test the potential of synovium-derived stem cells (SMSC) to regenerate cartilage using a matrix-associated implantation. In an osteochondral defect model...... of the medial femoral condyle in a rabbit, a collagen membrane was seeded with either culture-expanded allogenic chondrocytes or SMSC and then transplanted into the lesion. A tailored piece synovium served as a control. Rabbit SMSC formed typical cartilage in vitro. Macroscopic evaluation of defect healing...... and the thickness of the regenerated tissue did not reveal a significant difference between the intervention groups. However, instantaneous and shear modulus, reflecting the biomechanical strength of the repair tissue, was superior in the implantation group using allogenic chondrocytes (p
Editorial Commentary: The Acellular Osteochondral Allograft, the Emperor Has New Clothes.
Mandelbaum, Bert R; Chahla, Jorge
2017-12-01
For larger lesions (>2.5-cm 2 ), clinical evidence and practice have shown that fresh osteochondral allograft have good durability, with 88% return to sport and greater than 75% 10-year survival rates for treatment of large femoral condyle lesions. That said, the use of fresh osteochondral allografts in clinical practice is limited by the availability of acceptable donor tissues for eligible patients in a timely fashion. Significant diminution of chondrocyte viability and density occurs during the preservation and storage period. All osteochondral allografts are not equal in performance and outcome. Chondrocyte density and viability are critical for successful transplantation and outcome in the short and long term. This commentary highlights the high failure rates of tissue when it is acellular. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Osteochondral defect repair using a polyvinyl alcohol-polyacrylic acid (PVA-PAAc) hydrogel.
Bichara, David A; Bodugoz-Sentruk, Hatice; Ling, Doris; Malchau, Erik; Bragdon, Charles R; Muratoglu, Orhun K
2014-08-01
Poly(vinyl alcohol) (PVA) hydrogels can be candidates for articular cartilage repair due to their high water content. We synthesized a PVA-poly(acrylic acid) (PAAc) hydrogel formulation and determined its ability to function as a treatment option for condylar osteochondral (OC) defects in a New Zealand white rabbit (NZWR) model for 12 weeks and 24 weeks. In addition to hydrogel OC implants, tensile bar-shaped hydrogels were also implanted subcutaneously to evaluate changes in mechanical properties as a function of in vivo duration. There were no statistically significant differences (p > 0.05) in the water content measured in the OC hydrogel implant that was harvested after 12 weeks and 24 weeks, and non-implanted controls. There were no statistically significant differences (p > 0.05) in the break stress, strain at break or modulus of the tensile bars either between groups. Histological analysis of the OC defect, synovial capsule and fibrous tissue around the tensile bars determined hydrogel biocompatibility. Twelve-week hydrogels were found to be in situ flush with the articular cartilage; meniscal tissue demonstrated an intact surface. Twenty-four week hydrogels protruded from the defect site due to lack of integration with subchondral tissue, causing fibrillation to the meniscal surface. Condylar micro-CT scans ruled out osteolysis and bone cysts of the subchondral bone, and no PVA-PAAc hydrogel contents were found in the synovial fluid. The PVA-PAAc hydrogel was determined to be fully biocompatible, maintained its properties over time, and performed well at the 12 week time point. Physical fixation of the PVA-PAAc hydrogel to the subchondral bone is required to ensure long-term performance of hydrogel plugs for OC defect repair.
Tri-layered composite plug for the repair of osteochondral defects: in vivo study in sheep
Directory of Open Access Journals (Sweden)
Altug Yucekul
2017-04-01
Full Text Available Cartilage defects are a source of pain, immobility, and reduced quality of life for patients who have acquired these defects through injury, wear, or disease. The avascular nature of cartilage tissue adds to the complexity of cartilage tissue repair or regeneration efforts. The known limitations of using autografts, allografts, or xenografts further add to this complexity. Autologous chondrocyte implantation or matrix-assisted chondrocyte implantation techniques attempt to introduce cultured cartilage cells to defect areas in the patient, but clinical success with these are impeded by the avascularity of cartilage tissue. Biodegradable, synthetic scaffolds capable of supporting local cells and overcoming the issue of poor vascularization would bypass the issues of current cartilage treatment options. In this study, we propose a biodegradable, tri-layered (poly(glycolic acid mesh/poly(l-lactic acid-colorant tidemark layer/collagen Type I and ceramic microparticle-coated poly(l-lactic acid-poly(ϵ-caprolactone monolith osteochondral plug indicated for the repair of cartilage defects. The porous plug allows the continual transport of bone marrow constituents from the subchondral layer to the cartilage defect site for a more effective repair of the area. Assessment of the in vivo performance of the implant was conducted in an ovine model (n = 13. In addition to a control group (no implant, one group received the implant alone (Group A, while another group was supplemented with hyaluronic acid (0.8 mL at 10 mg/mL solution; Group B. Analyses performed on specimens from the in vivo study revealed that the implant achieves cartilage formation within 6 months. No adverse tissue reactions or other complications were reported. Our findings indicate that the porous biocompatible implant seems to be a promising treatment option for the cartilage repair.
Slaus, Mario; Cicvara-Pećina, Tatjana; Lucijanić, Ivica; Pećina, Marko; Stilinović, Davor
2010-06-01
Although osteochondritis dissecans of the knee has been known for a long time, we still do not fully understand why it develops. This prompted us to present and describe an example of osteochondritis dissecans identified in the Osteological Collection of the Croatian Academy of Sciences and Arts. The case of osteochondritis dissecans described in this report was recovered from the Gluvine kuće cemetery in the Dalmatian hinterland, approximately 28 km north-east of Split. A total of 77 graves were excavated and the individual exhibiting osteochondritis dissecans was recovered from grave number 16 that belongs to the younger phase of the cemetery that lasted during the second half of the 9th century A.D. Osteochondritis dissecans was noted in a subadult individual. The pathological changes consistent with osteochondritis dissecans are present on both medial femoral condyles. The lesion on the right femoral condyle is an oval crater-like defect with well defined margins and a porous floor of rough trabecular bone. The lesion on the left femoral condyle is basically, with two small provisions, identical to the one on the right side. The first is that it is slightly smaller, while the second is that unlike its antimere, it has a well preserved bone fragment that fits perfectly into the ostechondritic pit. Radiographic analyses of the femoral condyles support a diagnosis of osteochondritis dissecans and show a well-demarcated radiolucent defect in the articular surfaces of both joints surrounded by a thin sclerotic repair zone. According to the classification systems this degree of change corresponds to stage 3 or grade 3 osteochondritis dissecans--a detached but non-displaced fragment. Returning, for a second, to the opinion that prompted us to present this case, it is clear that during the last 1100 years there have been no significant morphological or radiological changes in the characteristics of osteochondritis dissecans.
Tang, Chris Yuk Kwan; Fung, Boris; Poon, T L; Fok, Margaret
2014-01-01
Even with the invention of locking plates, intra-articular fractures of distal radius with extreme comminution remain a challenge for orthopaedic surgeons. Osteochondral graft is a potential choice to reconstruct the articular defect. We report a patient who had a fracture of distal radius with costo-osteochondral graft for articular reconstruction which has not yet been described in the English literature. At nine-year follow-up, he was pain free and had full range of movement of the wrist. The authors suggest that costo-osteochondral graft could be an option with satisfactory result.
Sermer, Corey; Kandel, Rita; Anderson, Jesse; Hurtig, Mark; Theodoropoulos, John
2018-02-01
Current therapies for cartilage repair can be limited by an inability of the repair tissue to integrate with host tissue. Thus, there is interest in developing approaches to enhance integration. We have previously shown that platelet-rich plasma (PRP) improves cartilage tissue formation. This raised the question as to whether PRP could promote cartilage integration. Chondrocytes were isolated from cartilage harvested from bovine joints, seeded on a porous bone substitute and grown in vitro to form an osteochondral-like implant. After 7 days, the biphasic construct was soaked in PRP for 30 min before implantation into the core of a donut-shaped biphasic explant of native cartilage and bone. Controls were not soaked in PRP. The implant-explant construct was cultured for 2-4 weeks. PRP-soaked bioengineered implants integrated with host tissue in 73% of samples, whereas controls only integrated in 19% of samples. The integration strength, as determined by a push-out test, was significantly increased in the PRP-soaked implant group (219 ± 35.4 kPa) compared with controls (72.0 ± 28.5 kPa). This correlated with an increase in glycosaminoglycan and collagen accumulation in the region of integration in the PRP-treated implant group, compared with untreated controls. Immunohistochemical studies revealed that the integration zone contained collagen type II and aggrecan. The cells at the zone of integration in the PRP-soaked group had a 3.5-fold increase in matrix metalloproteinase-13 gene expression compared with controls. These results suggest that PRP-soaked bioengineered cartilage implants may be a better approach for cartilage repair due to enhanced integration. Copyright © 2017 John Wiley & Sons, Ltd.
Endo, J; Watanabe, A; Sasho, T; Yamaguchi, S; Saito, M; Akagi, R; Muramatsu, Y; Mukoyama, S; Katsuragi, J; Akatsu, Y; Fukawa, T; Okubo, T; Osone, F; Takahashi, K
2015-02-01
To investigate the effectiveness of quantitative Magnetic resonance imaging (MRI) for evaluating the quality of cartilage repair over time following allograft chondrocyte implantation using a three-dimensional scaffold for osteochondral lesions. Thirty knees from 15 rabbits were analyzed. An osteochondral defect (diameter, 4 mm; depth, 1 mm) was created on the patellar groove of the femur in both legs. The defects were filled with a chondrocyte-seeded scaffold in the right knee and an empty scaffold in the left knee. Five rabbits each were euthanized at 4, 8, and 12 weeks and their knees were examined via macroscopic inspection, histological and biochemical analysis, and quantitative MRI (T2 mapping and dGEMRIC) to assess the state of tissue repair following allograft chondrocyte implantation with a three-dimensional scaffold for osteochondral lesions. Comparatively good regenerative cartilage was observed both macroscopically and histologically. In both chondrocyte-seeded and control knees, the T2 values of repair tissues were highest at 4 weeks and showed a tendency to decrease with time. ΔR1 values of dGEMRIC also tended to decrease with time in both groups, and the mean ΔR1 was significantly lower in the CS-scaffold group than in the control group at all time points. ΔR1 = 1/r (R1post - R1pre), where r is the relaxivity of Gd-DTPA(2-), R1 = 1/T1 (longitudinal relaxation time). T2 mapping and dGEMRIC were both effective for evaluating tissue repair after allograft chondrocyte implantation. ΔR1 values of dGEMRIC represented good correlation with histologically and biochemically even at early stages after the implantation. Copyright © 2014 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Osteochondritis Dissecans of the Glenoid in a Major League Baseball Prospect: A Case Report.
Grau, Luis Carlos; Jose, Jean; Sama, Andrew Joseph; Baraga, Michael Gerald
2016-01-01
A 16-year-old Major League Baseball prospect presented with persistent shoulder pain associated with throwing. Magnetic resonance imaging (MRI) demonstrated a large osteochondritis dissecans lesion in the posterosuperior aspect of the glenoid. The patient was restricted from throwing and underwent therapy to improve range of motion and throwing mechanics. Eight months after initiating nonoperative treatment, an MRI arthrogram demonstrated a healed lesion. At follow-up 2 years after treatment, full relief of symptoms had persisted. Osteochondritis dissecans lesions of the glenoid are extremely rare, but have the potential to heal in overhead-throwing athletes. To our knowledge, this is the only case reported in the literature that demonstrates a healed osteochondritis dissecans lesion of the glenoid following nonoperative treatment.
Sullivan, Martin; Fraser, Ethan J; Linklater, James; Harris, Craig; Morgan, Kieran
2017-06-01
Talar osteochondral lesions represent challenging clinical entities, particularly in high-demand athletes. Surgical treatment of large lesions often requires a 2-step procedure, or the use of osteotomy in the case of autologous osteochondral transfer, which can delay return to sport. A professional rugby league player underwent surgery for a complex injury to the ankle. A talar osteochondral lesion with a maximal diameter of 15 mm was treated in an arthroscopic fashion using the cartilage taken from the completely displaced osteochondral fragment. Cartilage was cut into chips and combined with bone graft product containing platelet-derived growth factor and a porous collagen scaffold. Autologous cartilage was then reimplanted arthroscopically. The patient was allowed full ankle motion from 2 weeks postoperatively, and weightbearing was commenced at 6 weeks. Follow-up imaging and functional outcomes, including return to sport, were assessed at regular intervals. The patient was able to return to professional rugby league by 23 weeks postoperatively. Magnetic resonance imaging at 16 months postoperatively showed restoration of the subchondral plate and osseous infill. At final follow-up, the patient remained pain free and was playing at preinjury level. This report describes good outcomes using a novel, 1-step cartilage repair technique to treat a large talar osteochondral lesion in a professional athlete. Level V: Expert opinion.
Optimising femoral-head osteochondral allograft transplantation in a preclinical model
Directory of Open Access Journals (Sweden)
Brett D. Crist
2016-04-01
Conclusion: These data provide initial translational and clinical evidence for large osteochondral allografts as a potential option for functional resurfacing of full-thickness cartilage defects of the femoral head.
Chondroblastoma of the Knee Treated with Resection and Osteochondral Allograft Reconstruction
Directory of Open Access Journals (Sweden)
Judd Fitzgerald
2014-01-01
Full Text Available Case. This case report describes the operative management of 16-year-old male with a symptomatic chondroblastoma of the distal femur with breach of the chondral surface. Following appropriate imaging and core needle biopsy, the diagnosis was confirmed histologically. The patient then underwent intralesional curettage and osteochondral allograft reconstruction of the defect. At one-year follow-up the patient was pain-free and has obtained excellent range of motion. There is radiographic evidence of allograft incorporation and no evidence of local recurrence. Conclusion. Osteochondral allograft reconstruction is an effective option following marginal resection and curettage of chondroblastoma involving the chondral surface of the distal femur.
Natural Origin Materials for Osteochondral Tissue Engineering.
Bonani, Walter; Singhatanadgige, Weerasak; Pornanong, Aramwit; Motta, Antonella
2018-01-01
Materials selection is a critical aspect for the production of scaffolds for osteochondral tissue engineering. Synthetic materials are the result of man-made operations and have been investigated for a variety of tissue engineering applications. Instead, the products of physiological processes and the metabolic activity of living organisms are identified as natural materials. Over the recent decades, a number of natural materials, namely, biopolymers and bioceramics, have been proposed as the main constituent of osteochondral scaffolds, but also as cell carriers and signaling molecules. Overall, natural materials have been investigated both in the bone and in the cartilage compartment, sometimes alone, but often in combination with other biopolymers or synthetic materials. Biopolymers and bioceramics possess unique advantages over their synthetic counterparts due similarity with natural extracellular matrix, the presence of cell recognition sites and tunable chemistry. However, the characteristics of natural origin materials can vary considerably depending on the specific source and extraction process. A deeper understanding of the relationship between material variability and biological activity and the definition of standardized manufacturing procedures will be crucial for the future of natural materials in tissue engineering.
The "LIFT" lesion: lateral inverted osteochondral fracture of the talus.
Dunlap, Bradley J; Ferkel, Richard D; Applegate, Gregory R
2013-11-01
The purpose of this study was to assess a series of lateral inverted osteochondral fractures of the talus. Over a 17-year period, 10 patients with an acute lateral inverted osteochondral fracture of the talus after an inversion injury to the ankle were identified. Diagnosis was made by physical examination, radiographs, magnetic resonance imaging, and/or computed tomography scan. Arthroscopy was initially performed on all patients. All patients had an inverted osteochondral fragment. In 8 of 10 patients the fragment was reattached in an open manner in conjunction with lateral ligament reefing. The fragment was excised in 2 patients. The mean age of the patients was 17.2 years. They were evaluated with the Single Assessment Numeric Evaluation, American Orthopaedic Foot and Ankle Society Ankle-Hindfoot Scale, modified Weber score, Berndt and Harty score, and Short Form 36 version 2 score. Physical and radiographic examination was also performed. The mean time to follow-up was 112.3 months (9.3 years). The mean American Orthopaedic Foot and Ankle Society score improved from 18.9 preoperatively to 86.9 postoperatively (P ≤ .0001). The mean Single Assessment Numeric Evaluation and modified Weber scores were 81.6 and 81.5, respectively. On the Berndt and Harty scale, 6 patients had a good to excellent rating; 3, fair; and 1, poor. The mean Short Form 36 version 2 scores corresponded to national averages for healthy populations. Mean loss of motion for dorsiflexion and plantarflexion was 6.8° and 3.0°, respectively, when compared with the contralateral side. All patients showed some osteophyte formation on follow-up radiographs. An inverted osteochondral fracture of the lateral talus (lateral, inverted, fracture, talus [LIFT lesion]) can occur after a twisting injury to the ankle. Clinical suspicion should be high, especially in the younger athlete. This injury can be successfully managed with a combined arthroscopic and open approach. Level IV, therapeutic case
Yao, Hang; Kang, Junpei; Li, Weichang; Liu, Jian; Xie, Renjian; Wang, Yingjun; Liu, Sa; Wang, Dong-An; Ren, Li
2017-12-07
Cartilage repairing grafts have been widely studied, and osteochondral replacement hydrogels have proven to be an excellent method in research and clinical fields. However, it has been difficult to simultaneously solve three main issues in osteochondral replacement preparation: surface lubrication, overall mechanical support and good simulations of cell regeneration. A novel integrated bilayered hydrogel osteochondral replacement was constructed by blending polyvinyl alcohol (PVA) and β-tricalcium phosphate (β-TCP) in this study. Separated nano-ball milling with ultrasound dispersion prepared β-TCP demonstrated suitable properties of tiny particle size, high purity and ideal distribution, improving the mechanical properties of the novel integrated hydrogel, and providing a cartilage-like lubrication effect and high biocompatibility, including cytocompatibility and osteogenesis. The reinforcement of β-TCP and integrated molding technology enabled the hydrogel to demonstrate excellent component compatibility and good bonding between the two layers, which promoted the strengthening of the compression modulus and tensile modulus up to three times by mechanical testing. The surface lubrication properties of the novel osteochondral hydrogel were similar to the natural cartilage by friction coefficient characterization. The two layers of the novel integrated graft provided a considerable bio-function by co-culturing with chondrocytes and synovium mesenchymal stem cells: chondrocytes promoted adherence achieved by the upper density layer and better osteogenesis performance of the porous lower layer. The design of the bilayered β-TCP/PVA osteochondral hydrogel is promising for use in articular cartilage repair.
Osteochondral tissue engineering: scaffolds, stem cells and applications
Nooeaid, Patcharakamon; Salih, Vehid; Beier, Justus P; Boccaccini, Aldo R
2012-01-01
Osteochondral tissue engineering has shown an increasing development to provide suitable strategies for the regeneration of damaged cartilage and underlying subchondral bone tissue. For reasons of the limitation in the capacity of articular cartilage to self-repair, it is essential to develop approaches based on suitable scaffolds made of appropriate engineered biomaterials. The combination of biodegradable polymers and bioactive ceramics in a variety of composite structures is promising in this area, whereby the fabrication methods, associated cells and signalling factors determine the success of the strategies. The objective of this review is to present and discuss approaches being proposed in osteochondral tissue engineering, which are focused on the application of various materials forming bilayered composite scaffolds, including polymers and ceramics, discussing the variety of scaffold designs and fabrication methods being developed. Additionally, cell sources and biological protein incorporation methods are discussed, addressing their interaction with scaffolds and highlighting the potential for creating a new generation of bilayered composite scaffolds that can mimic the native interfacial tissue properties, and are able to adapt to the biological environment. PMID:22452848
Dhollander, Aad; Verdonk, Peter; Almqvist, Karl Fredrik; Verdonk, Rene; Victor, Jan
2015-12-01
Conflicting clinical outcomes have been reported recently with the use of an osteochondral scaffold plugs for cartilage repair in the knee. In this study, twenty patients were consecutively treated for their cartilage lesions with the synthetic plug technique. These patients were prospectively clinically evaluated with a mean follow-up of 34.15 months. Magnetic resonance imaging (MRI) was used for morphologic analysis of the cartilage repair. The patients included in this study showed a significant gradual clinical improvement after the osteochondral scaffold plug. However, this clinical improvement was not confirmed by the MRI findings of this cohort study. Subchondral bone changes were seen in all patients on MRI and deficient filling of the defect was noticed in in 30.7% of the cases at 24 months of follow-up. There was no evidence found to support osteoconductive bone ingrowth. Therefore, the use of this type of osteochondral scaffold plug in osteochondral repair is questionable. Level of evidence: IV.
Park, Ju Young; Choi, Jong-Cheol; Shim, Jin-Hyung; Lee, Jung-Seob; Park, Hyoungjun; Kim, Sung Won; Doh, Junsang; Cho, Dong-Woo
2014-09-01
Bioprinting is a promising technique for engineering composite tissues, such as osteochondral tissues. In this study, as a first step toward bioprinting-based osteochondral tissue regeneration, we systematically examined the behavior of chondrocytes and osteoblasts to hyaluronic acid (HA) and type I collagen (Col-1) hydrogels. First, we demonstrated that cells on hydrogels that were comprised of major native tissue extracellular matrix (ECM) components (i.e. chondrocytes on HA hydrogels and osteoblasts on Col-1 hydrogels) exhibited better proliferation and cell function than cells on non-native ECM hydrogels (i.e., chondrocytes on Col-1 hydrogels and osteoblasts on HA hydrogels). In addition, cells located near their native ECM hydrogels migrated towards them. Finally, we bioprinted three-dimensional (3D) osteochondral tissue-mimetic structures composed of two compartments, osteoblast-encapsulated Col-1 hydrogels and chondrocyte-encapsulated HA hydrogels, and found viability and functions of each cell type were well maintained within the 3D structures up to 14 days in vitro. These results suggest that with proper choice of hydrogel materials, bioprinting-based approaches can be successfully applied for osteochondral tissue regeneration.
de Lange, G.L.; Overman, J.R.; Farre-Guasch, E.; Korstjens, C.M.; Hartman, B.; Langenbach, G.E.J.; van Duin, M.A.; Klein-Nulend, J.
2014-01-01
Objective The gain of mineralized bone was compared between deproteinized bovine bone allograft (DBA) and biphasic calcium phosphate (BCP) for dental implant placement. Study Design Five patients with atrophic maxillae underwent bilateral sinus elevation with DBA (Bio-Oss) and BCP (Straumann
3D printing of novel osteochondral scaffolds with graded microstructure
Nowicki, Margaret A.; Castro, Nathan J.; Plesniak, Michael W.; Zhang, Lijie Grace
2016-10-01
Osteochondral tissue has a complex graded structure where biological, physiological, and mechanical properties vary significantly over the full thickness spanning from the subchondral bone region beneath the joint surface to the hyaline cartilage region at the joint surface. This presents a significant challenge for tissue-engineered structures addressing osteochondral defects. Fused deposition modeling (FDM) 3D bioprinters present a unique solution to this problem. The objective of this study is to use FDM-based 3D bioprinting and nanocrystalline hydroxyapatite for improved bone marrow human mesenchymal stem cell (hMSC) adhesion, growth, and osteochondral differentiation. FDM printing parameters can be tuned through computer aided design and computer numerical control software to manipulate scaffold geometries in ways that are beneficial to mechanical performance without hindering cellular behavior. Additionally, the ability to fine-tune 3D printed scaffolds increases further through our investment casting procedure which facilitates the inclusion of nanoparticles with biochemical factors to further elicit desired hMSC differentiation. For this study, FDM was used to print investment-casting molds innovatively designed with varied pore distribution over the full thickness of the scaffold. The mechanical and biological impacts of the varied pore distributions were compared and evaluated to determine the benefits of this physical manipulation. The results indicate that both mechanical properties and cell performance improve in the graded pore structures when compared to homogeneously distributed porous and non-porous structures. Differentiation results indicated successful osteogenic and chondrogenic manipulation in engineered scaffolds.
Anatomic feature of deltoid ligament attachment in posteromedial osteochondral lesion of talar dome.
Nakasa, Tomoyuki; Sawa, Mikiya; Ikuta, Yasunari; Yoshikawa, Masahiro; Tsuyuguchi, Yusuke; Adachi, Nobuo
2018-03-01
Osteochondral lesions of the talus (OLT) are recognized as being commonly associated with trauma. However, the etiology of OLT remains unclear. In the case of a posteromedial lesion of OLT (medial OLT), the deep layer of the deltoid ligament is located close to the medial OLT, and this relationship between a medial lesion and deltoid ligament could be a risk factor for medial OLT. The purpose of this study is to investigate the unique anatomic feature of the deep deltoid attachment to the talus in patients with medial OLT compared with patients with non-medial OLT. Forty ankles with medial OLT and 40 ankles without medial OLT were retrospectively reviewed in this study. On the coronal images of MRI, the attachment of deltoid ligament was measured. The continuity of the osteochondral fragment and its bed was evaluated on MRI and arthroscopic findings. Coronal MRI images showed that the attachment of the deep deltoid ligament to the medial OLT was broader and located more proximally than in non-medial OLT. The continuity of fibers from the insertion site of deltoid ligament to the talus to the osteochondral fragment was observed (76.7%). In the arthroscopic findings, the osteochondral fragment was obviously connected to the talus at the medial site in 85.2% of feet. The location of the deep deltoid ligament attachment to the medial OLT was more proximal and there was the possibility of these anatomic feature might contribute to the pathogenesis of medial OLT. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Mediated water electrolysis in biphasic systems.
Scanlon, Micheál D; Peljo, Pekka; Rivier, Lucie; Vrubel, Heron; Girault, Hubert H
2017-08-30
The concept of efficient electrolysis by linking photoelectrochemical biphasic H 2 evolution and water oxidation processes in the cathodic and anodic compartments of an H-cell, respectively, is introduced. Overpotentials at the cathode and anode are minimised by incorporating light-driven elements into both biphasic reactions. The concepts viability is demonstrated by electrochemical H 2 production from water splitting utilising a polarised water-organic interface in the cathodic compartment of a prototype H-cell. At the cathode the reduction of decamethylferrocenium cations ([Cp 2 *Fe (III) ] + ) to neutral decamethylferrocene (Cp 2 *Fe (II) ) in 1,2-dichloroethane (DCE) solvent takes place at the solid electrode/oil interface. This electron transfer process induces the ion transfer of a proton across the immiscible water/oil interface to maintain electroneutrality in the oil phase. The oil-solubilised proton immediately reacts with Cp 2 *Fe (II) to form the corresponding hydride species, [Cp 2 *Fe (IV) (H)] + . Subsequently, [Cp 2 *Fe (IV) (H)] + spontaneously undergoes a chemical reaction in the oil phase to evolve hydrogen gas (H 2 ) and regenerate [Cp 2 *Fe (III) ] + , whereupon this catalytic Electrochemical, Chemical, Chemical (ECC') cycle is repeated. During biphasic electrolysis, the stability and recyclability of the [Cp 2 *Fe (III) ] + /Cp 2 *Fe (II) redox couple were confirmed by chronoamperometric measurements and, furthermore, the steady-state concentration of [Cp 2 *Fe (III) ] + monitored in situ by UV/vis spectroscopy. Post-biphasic electrolysis, the presence of H 2 in the headspace of the cathodic compartment was established by sampling with gas chromatography. The rate of the biphasic hydrogen evolution reaction (HER) was enhanced by redox electrocatalysis in the presence of floating catalytic molybdenum carbide (Mo 2 C) microparticles at the immiscible water/oil interface. The use of a superhydrophobic organic electrolyte salt was critical to
Oliveira, Isabel; Carvalho, Ana L; Radhouani, Hajer; Gonçalves, Cristiana; Oliveira, J Miguel; Reis, Rui L
2018-01-01
The osteochondral defect (OD) comprises the articular cartilage and its subchondral bone. The treatment of these lesions remains as one of the most problematic clinical issues, since these defects include different tissues, requiring distinct healing approaches. Among the growing applications of regenerative medicine, clinical articular cartilage repair has been used for two decades, and it is an effective example of translational medicine; one of the most used cell-based repair strategies includes implantation of autologous cells in degradable scaffolds such as alginate, agarose, collagen, chitosan, chondroitin sulfate, cellulose, silk fibroin, hyaluronic acid, and gelatin, among others. Concerning the repair of osteochondral defects, tissue engineering and regenerative medicine started to design single- or bi-phased scaffold constructs, often containing hydroxyapatite-collagen composites, usually used as a bone substitute. Biomolecules such as natural and synthetic have been explored to recreate the cartilage-bone interface through multilayered biomimetic scaffolds. In this chapter, a succinct description about the most relevant natural and synthetic biomolecules used on cartilage and bone repair, describing the procedures to obtain these biomolecules, their chemical structure, common modifications to improve its characteristics, and also their application in the biomedical fields, is given.
International Nuclear Information System (INIS)
Mohr, A.; Bergmann, I.; Muhle, C.; Heller, M.; Heiss, C.; Schrader, C.; Roemer, F.W.; Lynch, J.A.; Genant, H.K.
2003-01-01
Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic information is not necessary, an alternative to light microscopy for the investigation of osteochondritis dissecans. Osteochondritis dissecans micro-CT histology comparative investigation
International Nuclear Information System (INIS)
Park, Ju Young; Choi, Jong-Cheol; Lee, Jung-Seob; Park, Hyoungjun; Doh, Junsang; Cho, Dong-Woo; Shim, Jin-Hyung; Kim, Sung Won
2014-01-01
Bioprinting is a promising technique for engineering composite tissues, such as osteochondral tissues. In this study, as a first step toward bioprinting-based osteochondral tissue regeneration, we systematically examined the behavior of chondrocytes and osteoblasts to hyaluronic acid (HA) and type I collagen (Col-1) hydrogels. First, we demonstrated that cells on hydrogels that were comprised of major native tissue extracellular matrix (ECM) components (i.e. chondrocytes on HA hydrogels and osteoblasts on Col-1 hydrogels) exhibited better proliferation and cell function than cells on non-native ECM hydrogels (i.e., chondrocytes on Col-1 hydrogels and osteoblasts on HA hydrogels). In addition, cells located near their native ECM hydrogels migrated towards them. Finally, we bioprinted three-dimensional (3D) osteochondral tissue-mimetic structures composed of two compartments, osteoblast-encapsulated Col-1 hydrogels and chondrocyte-encapsulated HA hydrogels, and found viability and functions of each cell type were well maintained within the 3D structures up to 14 days in vitro. These results suggest that with proper choice of hydrogel materials, bioprinting-based approaches can be successfully applied for osteochondral tissue regeneration. (paper)
Clearfield, Drew; Nguyen, Andrew; Wei, Mei
2018-04-01
The zonal organization of osteochondral tissue underlies its long term function. Despite this, tissue engineering strategies targeted for osteochondral repair commonly rely on the use of isotropic biomaterials for tissue reconstruction. There exists a need for a new class of highly biomimetic, anisotropic scaffolds that may allow for the engineering of new tissue with zonal properties. To address this need, we report the facile production of monolithic multidirectional collagen-based scaffolds that recapitulate the zonal structure and composition of osteochondral tissue. First, superficial and osseous zone-mimicking scaffolds were fabricated by unidirectional freeze casting collagen-hyaluronic acid and collagen-hydroxyapatite-containing suspensions, respectively. Following their production, a lyophilization bonding process was used to conjoin these scaffolds with a distinct collagen-hyaluronic acid suspension mimicking the composition of the transition zone. Resulting matrices contained a thin, highly aligned superficial zone that interfaced with a cellular transition zone and vertically oriented calcified cartilage and osseous zones. Confocal microscopy confirmed a zone-specific localization of hyaluronic acid, reflecting the depth-dependent increase of glycosaminoglycans in the native tissue. Poorly crystalline, carbonated hydroxyapatite was localized to the calcified cartilage and osseous zones and bordered the transition zone. Compressive testing of hydrated scaffold zones confirmed an increase of stiffness with scaffold depth, where compressive moduli of chondral and osseous zones fell within or near ranges conducive for chondrogenesis or osteogenesis of mesenchymal stem cells. With the combination of these biomimetic architectural and compositional cues, these multidirectional scaffolds hold great promise for the engineering of zonal osteochondral tissue. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 948-958, 2018. © 2017 Wiley Periodicals
Directory of Open Access Journals (Sweden)
Luiz Augusto de Souza
2011-12-01
Full Text Available In this study, serum alkaline phosphatase activity was measured in response to the repair of osteochondral defects in twenty-four New Zealand rabbits. The animals were divided into three groups: a control (GC, those treated with bone marrow mononuclear cells (GCM and those that received mononuclear cells with autologous bone morphogenetic protein (BMP + GCM. After exposing the trochlear groove of the left stifle joint, a wedge-shaped segment was removed. Later, the defect was filled with an osteochondral autograft preserved in 98% glycerin. For the GC group, only the bone graft was performed. For the GCM, in addition to the graft, 2x106 seed mononuclear cells were implanted. For the GCM + BMP, the same number of cells, associated with 1μg of bone morphogenetic protein, were intraarticularly administered. The osteoblastic response was measured by analyzing the serum alkaline phosphatase on day 0 (preoperative 3, 15, 30, and 45 after surgery, and by radiographic examinations. Analysis of variance in randomized blocks, factorial and Tukey’s test (p = 0.05 were made. The overall mean GCM was superior to the other groups and the highest rates were among the 15th and 45th days postoperatively. The discrepancy in values between individuals of the same group casts doubts on the veracity of the test.
Directory of Open Access Journals (Sweden)
Baoshan Xu
Full Text Available Tissue engineering has provided an alternative therapeutic possibility for degenerative disc diseases. However, we lack an ideal scaffold for IVD tissue engineering. The goal of this study is to fabricate a novel biomimetic biphasic scaffold for IVD tissue engineering and evaluate the feasibility of developing tissue-engineered IVD in vitro and in vivo. In present study we developed a novel integrated biphasic IVD scaffold using a simple freeze-drying and cross-linking technique of pig bone matrix gelatin (BMG for the outer annulus fibrosus (AF phase and pig acellular cartilage ECM (ACECM for the inner nucleus pulposus (NP phase. Histology and SEM results indicated no residual cells remaining in the scaffold that featured an interconnected porous microstructure (pore size of AF and NP phase 401.4 ± 13.1 μm and 231.6 ± 57.2 μm, respectively. PKH26-labeled AF and NP cells were seeded into the scaffold and cultured in vitro. SEM confirmed that seeded cells could anchor onto the scaffold. Live/dead staining showed that live cells (green fluorescence were distributed in the scaffold, with no dead cells (red fluorescence being found. The cell-scaffold constructs were implanted subcutaneously into nude mice and cultured for 6 weeks in vivo. IVD-like tissue formed in nude mice as confirmed by histology. Cells in hybrid constructs originated from PKH26-labeled cells, as confirmed by in vivo fluorescence imaging system. In conclusion, the study demonstrates the feasibility of developing a tissue-engineered IVD in vivo with a BMG- and ACECM-derived integrated AF-NP biphasic scaffold. As well, PKH26 fluorescent labeling with in vivo fluorescent imaging can be used to track cells and analyse cell--scaffold constructs in vivo.
Bahmer, Andreas; Baumann, Uwe
2016-10-01
Triphasic pulse stimulation prevents from facial nerve stimulation (FNS) because of a different electromyographic input-output function compared with biphasic pulse stimulation. FNS is sometimes observed in cochlear implant users as an unwanted side effect of electrical stimulation of the auditory nerve. The common stimulation applied in current cochlear implant consists of biphasic pulse patterns. Two common clinical remedies to prevent unpleasant FNS caused by activation of certain electrodes are to expand their pulse phase duration or simply deactivate them. Unfortunately, in some patients these methods do not provide sufficient FNS prevention. In these patients triphasic pulse can prevent from FNS. The underlying mechanism is yet unclear. Electromyographic (EMG) recordings of muscles innervated by the facial nerve (musculi orbicularis ori and oculi) were applied to quantitatively assess the effects on FNS. Triphasic and biphasic fitting maps were compared in four subjects with severe FNS. Based on the recordings, a model is presented which intends to explain the beneficial effects of triphasic pulse application. Triphasic stimulation provided by fitting of an OPUS 2 speech processor device. For three patients, EMG was successfully recorded depending on stimulation level up to uncomfortable and intolerable FNS stimulation as upper boarder. The obtained EMG recordings demonstrated high individual variability. However, a difference between the input-output function for biphasic and triphasic pulse stimulation was visually observable. Compared with standard biphasic stimulation, triphasic pulses require higher stimulation levels to elicit an equal amount of FNS, as reflected by EMG amplitudes. In addition, we assume a steeper slope of the input-output function for biphasic pulse stimulation compared with triphasic pulse stimulation. Triphasic pulse stimulation prevents from FNS because of a smaller gradient of EMG input-output function compared with biphasic pulse
Biphasic calcium phosphate–casein bone graft fortified with Cassia
Indian Academy of Sciences (India)
Biphasic calcium phosphate; bone graft; Cassia occidentalis; simulated body fluid; SaOS-2 cell line. ... The study investigates the efficacy of CO extract incorporated biphasic calcium phosphate as an osteoinductive material. ... Current Issue
Review of biphasic insulin aspart in the treatment of type 1 and 2 diabetes
Directory of Open Access Journals (Sweden)
Nazia Raja-Khan
2008-01-01
Full Text Available Nazia Raja-Khan, Sarah S Warehime, Robert A GabbayDivision of Endocrinology, Diabetes, and Metabolism, Penn State Institute for Diabetes and Obesity, Pennsylvania State University College of Medicine, Hershey, Pennsylvania, USABackground: Insulin is an effective treatment for achieving glycemic control and preventing complications in patients with diabetes. In order to make insulin therapy more acceptable to patients, newer formulations of insulin have been developed, such as biphasic insulins. Biphasic insulins conveniently provide both prandial and basal insulin in a single injection. One of the most well-studied biphasic insulins is biphasic insulin aspart 70/30.Objective: Our goal was to review the current literature on the safety and efficacy of biphasic insulin aspart in type 1 and type 2 diabetes.Methods: A MEDLINE search was conducted using the terms “biphasic insulin aspart” to identify clinical studies and reviews.Results: Biphasic insulin aspart more effectively reduces post-prandial glucose compared to other biphasic insulins and basal insulins. Compared to biphasic insulin aspart, fasting glucose levels are lower with NPH, similar with glargine, and similar or lower with biphasic human insulin. Treat-to-target trials have shown that a goal HbA1c below 6.5 or 7% can be achieved with biphasic insulin aspart. The risk of hypoglycemia is similar to or less than that seen with other biphasic insulins or NPH insulin.Conclusion: Biphasic insulin aspart 70/30 is a safe and effective treatment option for patients with diabetes.Keywords: biphasic insulin aspart, insulin, diabetes
Di Luca, Andrea; Klein Gunnewiek, Michel; Vancso, Julius; van Blitterswijk, Clemens; Benetti, Edmondo Maria; Moroni, Lorenzo
2017-01-01
Engineering the osteochondral tissue presents some challenges mainly relying in its function of transition from the subchondral bone to articular cartilage and the gradual variation in several biological, mechanical, and structural features. A possible solution for osteochondral regeneration might
Ko, Ji-Yun; Kim, Kyung-Il; Park, Siyeon; Im, Gun-Il
2014-04-01
The purpose of this study was to investigate the chondrogenic features of human induced pluripotent stem cells (hiPSCs) and examine the differences in the chondrogenesis between hiPSCs and human bone marrow-derived MSCs (hBMMSCs). Embryoid bodies (EBs) were formed from undifferentiated hiPSCs. After EBs were dissociated into single cells, chondrogenic culture was performed in pellets and alginate hydrogel. Chondro-induced hiPSCs were implanted in osteochondral defects created on the patellar groove of immunosuppressed rats and evaluated after 12 weeks. The ESC markers NANOG, SSEA4 and OCT3/4 disappeared while the mesodermal marker BMP-4 appeared in chondro-induced hiPSCs. After 21 days of culture, greater glycosaminoglycan contents and better chondrocytic features including lacuna and abundant matrix formation were observed from chondro-induced hiPSCs compared to chondro-induced hBMMSCs. The expression of chondrogenic markers including SOX-9, type II collagen, and aggrecan in chondro-induced hiPSCs was comparable to or greater than chondro-induced hBMMSCs. A remarkably low level of hypertrophic and osteogenic markers including type X collagen, type I collagen and Runx-2 was noted in chondro-induced hiPSCs compared to chondro-induced hBMMSCs. hiPSCs had significantly greater methylation of several CpG sites in COL10A1 promoter than hBMMSCs in either undifferentiated or chondro-induced state, suggesting an epigenetic cause of the difference in hypertrophy. The defects implanted with chondro-induced hiPSCs showed a significantly better quality of cartilage repair than the control defects, and the majority of cells in the regenerated cartilage consisted of implanted hiPSCs. Copyright © 2014 Elsevier Ltd. All rights reserved.
Progress on the biphase turbine at Cerro Prieto
Energy Technology Data Exchange (ETDEWEB)
Cerini, D.; Hays, L.; Studhalter, W. [Douglas Energy Company, Placentia, CA (United States)
1997-12-31
The status of a Biphase turbine power plant being installed at the Cerro Prieto geothermal field is presented. The major modules for the power plant are completed except for a back pressure steam turbine. The power plant will be started in April 1997 with the Biphase turbine alone followed by the addition of the steam turbine module two months later. The current power plant performance level is 2780 kWe due to a decline in the well. An increase in power output to 4060 kWe by adding the flow from another well is planned. The addition of five Biphase power plants with a total power output of 21.2 megawatts is described.
International Nuclear Information System (INIS)
Schibany, N.; Ba-Ssalamah, A.; Marlovits, S.; Mlynarik, V.; Noebauer-Huhmann, I.M.; Striessnig, G.; Shodjai-Baghini, M.; Heinze, G.; Trattnig, S.
2005-01-01
Objective: To evaluate high field magnetic resonance (MR) imaging for imaging of osteochondral defects. Materials and methods: Nine osteochondral defects were simulated in three cadaveric talus specimens using a diamond drill. All specimens were examined on a 1.0 T MR unit and a 3.0 T MR unit. A T2-weighted turbo spin-echo (TSE) sequence with a 2 mm slice thickness and a 256 x 256 matrix size was used on both scanners. The visibility of the osteochondral separation and the presence of susceptibility artifacts at the drilling bores were scored on all images. Results: Compared to the 1.0 T MR unit, the protocol on the 3.0 T MR unit allowed a better delineation of the disruption of the articular cartilage and a better demarcation of the subchondral defect. Differences regarding the visualization of the subchondral defect were found to be statistically significant (P 0.05). The average SNR was higher using 3.0 T MRI (SNR = 12), compared to 1.0 T MRI (SNR = 7). Conclusion: High field MRI enables the acquisition of images with sufficient resolution and higher SNR and has therefore the potential to improve the staging of osteochondral defects
Lane, John; Healey, Robert; Amiel, David
2009-12-01
To better understand the changes in the cartilage coefficient of friction (COF) after an osteochondral repair, an assessment of dynamic loads has been developed using a goat knee model. The application of hyaluronan (HA) was also assessed for its lubricative properties and the resulting COF of the knee after osteochondral repair. A total of 18 caprine knees were dissected and mounted into an Instron load frame (Instron, Norwood, MA) for testing. The COF was measured in 10 knees relative to the normal, unaltered joint and then calibrated to account for friction of the system. These experimental knees were tested in 5 modes: normal; empty 4.5-mm defect; and osteochondral repairs that were elevated, flush, or depressed relative to the cartilage surface. Saline solution lavage kept the knees moist during testing. The effect of HA was evaluated after mechanical testing. Eight knees were used to study the effect of lavage on the joints because of the significant increase in the COF that it produced. Whereas all modes increased the COF from normal levels, the most significant changes occurred when there was proud placement. Increases of 4 times the normal friction levels were measured. Increases in the COF were also associated with saline solution lavage (0.006 to 0.046). There was a significant reduction in friction after HA injection, which reduced the COF to near-normal levels. There is a significant increase in the COF associated with saline solution lavage and an osteochondral plug being left proud, which can be temporarily reduced with a lubricative material such as HA. Dramatic increases in the COF can potentially damage chondrocytes when the patient begins articulating the joint after surgery. Such injuries may affect the ability of the cartilage to heal fully. Reducing the elevated COF with lubricating materials, such as HA, is recommended based on the results of this study.
Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M
1992-03-01
We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.
Costo-osteochondral graft for post-traumatic osteonecrosis of the radial head in an adolescent boy.
Iwai, S; Sato, K; Nakamura, T; Okazaki, M; Itoh, Y; Toyama, Y; Ikegami, H
2011-01-01
We present a case of post-traumatic osteonecrosis of the radial head in a 13-year-old boy which was treated with costo-osteochondral grafts. A satisfactory outcome was seen at a follow-up of two years and ten months. Although costo-osteochondral grafting has been used in the treatment of defects in articular cartilage, especially in the hand and the elbow, the extension of the technique to manage post-traumatic osteonecrosis of the radial head in a child has not previously been reported in the English language literature. Complete relief of pain was obtained and an improvement in the range of movement was observed. The long-term results remain uncertain.
Jayabalan, Prakash; Tan, Andrea R; Rahaman, Mohammed N; Bal, B Sonny; Hung, Clark T; Cook, James L
2011-10-01
Replacement of diseased areas of the joint with tissue-engineered osteochondral grafts has shown potential in the treatment of osteoarthritis. Bioactive glasses are candidates for the osseous analog of these grafts. (1) Does Bioactive Glass 13-93 (BG 13-93) as a subchondral substrate improve collagen and glycosaminoglycan production in a tissue-engineered cartilage layer? (2) Does BG 13-93 as a culture medium supplement increase the collagen and glycosaminoglycan production and improve the mechanical properties in a tissue-engineered cartilage layer? In Study 1, bioactive glass samples (n = 4) were attached to a chondrocyte-seeded agarose layer to form an osteochondral construct, cultured for 6 weeks, and compared to controls. In Study 2, bioactive glass samples (n = 5) were cocultured with cell-seeded agarose for 6 weeks. The cell-seeded agarose layer was exposed to BG 13-93 either continuously or for the first or last 2 weeks in culture or had no exposure. Osteochondral constructs with a BG 13-93 base had improved glycosaminoglycan deposition but less collagen II content. Agarose scaffolds that had a temporal exposure to BG 13-93 within the culture medium had improved mechanical and biochemical properties compared to continuous or no exposure. When used as a subchondral substrate, BG 13-93 did not improve biochemical properties compared to controls. However, as a culture medium supplement, BG 13-93 improved the biochemical and mechanical properties of a tissue-engineered cartilage layer. BG 13-93 may not be suitable in osteochondral constructs but could have potential as a medium supplement for neocartilage formation.
Generic Model-Based Tailor-Made Design and Analysis of Biphasic Reaction Systems
DEFF Research Database (Denmark)
Anantpinijwatna, Amata
systems have a broad range of application, such as the manufacture of petroleum based chemicals, pharmaceuticals, and agro-bio products. Major considerations in the design and analysis of biphasic reaction systems are physical and chemical equilibria, kinetic mechanisms, and reaction rates. The primary...... contribution of this thesis is the development of a systematic modelling framework for the biphasic reaction system. The developed framework consists of three modules describing phase equilibria, reactions and mass transfer, and material balances of such processes. Correlative and predictive thermodynamic......Biphasic reaction systems are composed of immiscible aqueous and organic liquid phases where reactants, products, and catalysts are partitioned. These biphasic conditions point to novel synthesis paths, higher yields, and faster reactions, as well as facilitate product separation. The biphasic...
Cotter, Eric J; Waterman, Brian R; Kelly, Mick P; Wang, Kevin C; Frank, Rachel M; Cole, Brian J
2017-08-01
Symptomatic patellofemoral chondral lesions are a challenging clinical entity, as these defects may result from persistent lateral patellar maltracking or repetitive microtrauma. Anteromedializing tibial tubercle osteotomy has been shown to be an effective strategy for primary and adjunctive treatment of focal or diffuse patellofemoral disease to improve the biomechanical loading environment. Similarly, osteochondral allograft transplantation has proven efficacy in physiologically young, high-demand patients with condylar or patellofemoral lesions, particularly without early arthritic progression. The authors present the surgical management of a young athlete with symptomatic tricompartmental focal chondral defects with fresh osteochondral allograft transplantation and anteromedializing tibial tubercle osteotomy.
Treatment of osteochondral lesions in the knee using a cell-free scaffold.
Verdonk, P; Dhollander, A; Almqvist, K F; Verdonk, R; Victor, J
2015-03-01
The treatment of osteochondral lesions is of great interest to orthopaedic surgeons because most lesions do not heal spontaneously. We present the short-term clinical outcome and MRI findings of a cell-free scaffold used for the treatment of these lesions in the knee. A total of 38 patients were prospectively evaluated clinically for two years following treatment with an osteochondral nanostructured biomimetic scaffold. There were 23 men and 15 women; the mean age of the patients was 30.5 years (15 to 64). Clinical outcome was assessed using the Knee Injury and Osteoarthritis Outcome Score (KOOS), the Tegner activity scale and a Visual Analgue scale for pain. MRI data were analysed based on the Magnetic Resonance Observation of Cartilage Repair Tissue (MOCART) scoring system at three, 12 and 24 months post-operatively. There was a continuous significant clinical improvement after surgery. In two patients, the scaffold treatment failed (5.3%) There was a statistically significant improvement in the MOCART precentage scores. The repair tissue filled most of the defect sufficiently. We found subchondral laminar changes in all patients. Intralesional osteophytes were found in two patients (5.3%). We conclude that this one-step scaffold-based technique can be used for osteochondral repair. The surgical technique is straightforward, and the clinical results are promising. The MRI aspects of the repair tissue continue to evolve during the first two years after surgery. However, the subchondral laminar and bone changes are a concern. ©2015 The British Editorial Society of Bone & Joint Surgery.
Equivalence between short-time biphasic and incompressible elastic material responses.
Ateshian, Gerard A; Ellis, Benjamin J; Weiss, Jeffrey A
2007-06-01
Porous-permeable tissues have often been modeled using porous media theories such as the biphasic theory. This study examines the equivalence of the short-time biphasic and incompressible elastic responses for arbitrary deformations and constitutive relations from first principles. This equivalence is illustrated in problems of unconfined compression of a disk, and of articular contact under finite deformation, using two different constitutive relations for the solid matrix of cartilage, one of which accounts for the large disparity observed between the tensile and compressive moduli in this tissue. Demonstrating this equivalence under general conditions provides a rationale for using available finite element codes for incompressible elastic materials as a practical substitute for biphasic analyses, so long as only the short-time biphasic response is sought. In practice, an incompressible elastic analysis is representative of a biphasic analysis over the short-term response deltatelasticity tensor, and K is the hydraulic permeability tensor of the solid matrix. Certain notes of caution are provided with regard to implementation issues, particularly when finite element formulations of incompressible elasticity employ an uncoupled strain energy function consisting of additive deviatoric and volumetric components.
Shen, Na; Liang, Qiong; Liu, Yuehong; Lai, Bin; Li, Wen; Wang, Zhengmin; Li, Shufeng
2016-06-15
Intracochlear application of exogenous or transgenic neurotrophins, such as neurotrophin-3 (NT-3) and brain derived neurotrophic factor (BDNF), could promote the resprouting of spiral ganglion neuron (SGN) neurites in deafened animals. These resprouting neurites might reduce the gap between cochlear implant electrodes and their targeting SGNs, allowing for an improvement of spatial resolution of electrical stimulation. This study is to investigate the impact of electrical stimulation employed in CI on the extension of resprouting SGN neurites. We established an in vitro model including the devices delivering charge-balanced biphasic electrical stimulation, and spiral ganglion (SG) dissociated culture treated with BDNF and NT-3. After electrical stimulation with varying durations and intensities, we quantified neurite lengths and Schwann cell densities in SG cultures. Stimulations that were greater than 50μA or longer than 8h significantly decreased SG neurite length. Schwann cell density under 100μA electrical stimulation for 48h was significantly lower compared to that in non-stimulated group. These electrical stimulation-induced decreases of neurite extension and Schwann cell density were attenuated by various types of voltage-dependent calcium channel (VDCC) blockers, or completely prevented by their combination, cadmium or calcium-free medium. Our study suggested that charge-balanced biphasic electrical stimulation inhibited the extension of resprouting SGN neurites and decreased Schwann cell density in vitro. Calcium influx through multiple types of VDCCs was involved in the electrical stimulation-induced inhibition. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Lu, Steven; Lam, Johnny; Trachtenberg, Jordan E; Lee, Esther J; Seyednejad, Hajar; van den Beucken, Jeroen J J P; Tabata, Yasuhiko; Kasper, F Kurtis; Scott, David W; Wong, Mark E; Jansen, John A; Mikos, Antonios G
2015-12-01
The present work investigated correlations between cartilage and subchondral bone repair, facilitated by a growth factor-delivering scaffold, in a rabbit osteochondral defect model. Histological scoring indices and microcomputed tomography morphological parameters were used to evaluate cartilage and bone repair, respectively, at 6 and 12 weeks. Correlation analysis revealed significant associations between specific cartilage indices and subchondral bone parameters that varied with location in the defect (cortical vs. trabecular region), time point (6 vs. 12 weeks), and experimental group (insulin-like growth factor-1 only, bone morphogenetic protein-2 only, or both growth factors). In particular, significant correlations consistently existed between cartilage surface regularity and bone quantity parameters. Overall, correlation analysis between cartilage and bone repair provided a fuller understanding of osteochondral repair and can help drive informed studies for future osteochondral regeneration strategies.
Huang, Jian; Walcott, Gregory P; Ruse, Richard B; Bohanan, Scott J; Killingsworth, Cheryl R; Ideker, Raymond E
2012-09-11
We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.
Energy Technology Data Exchange (ETDEWEB)
Zhang Lingli; Fan Hongsong; Zhang Xingdong [National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, Sichuan 610064 (China); Hanagata, Nobutaka; Ikoma, Toshiyuki [Biomaterials Center, National Institute for Materials Science, Tsukuba, Ibaraki 305-0047 (Japan); Maeda, Megumi; Minowa, Takashi, E-mail: HANAGATA.Nobutaka@nims.go.j [Nanotechnology Innovation Center, National Institute for Materials Science, Tsukuba, Ibaraki 305-0047 (Japan)
2009-04-15
Because calcium phosphate (Ca-P) ceramics have been used as bone substitutes, it is necessary to investigate what effects the ceramics have on osteoblast maturation. We prepared three types of Ca-P ceramics with different Ca-P ratios, i.e. hydroxyapatite (HA), beta-tricalcium phosphate ({beta}-TCP), and biphasic calcium phosphate (BCP) ceramics with dense-smooth and porous structures. Comprehensive gene expression microarray analysis of mouse osteoblast-like cells cultured on these ceramics revealed that porous Ca-P ceramics considerably affected the gene expression profiles, having a higher potential for osteoblast maturation. In the in vivo study that followed, porous Ca-P ceramics were implanted into rat skeletal muscle. Sixteen weeks after the implantation, more alkaline-phosphatase-positive cells were observed in the pores of hydroxyapatite and BCP, and the expression of the osteocalcin gene (an osteoblast-specific marker) in tissue grown in pores was also higher in hydroxyapatite and BCP than in {beta}-TCP. In the pores of any Ca-P ceramics, 16 weeks after the implantation, we detected the expressions of marker genes of the early differentiation stage of chondrocytes and the complete differentiation stage of adipocytes, which originate from mesenchymal stem cells, as well as osteoblasts. These marker gene expressions were not observed in the muscle tissue surrounding the implanted Ca-P ceramics. These observations indicate that porous hydroxyapatite and BCP had a greater potential for promoting the differentiation of mesenchymal stem cells into osteoblasts than {beta}-TCP.
Wada, Susumu; Kitamura, Nobuto; Nonoyama, Takayuki; Kiyama, Ryuji; Kurokawa, Takayuki; Gong, Jian Ping; Yasuda, Kazunori
2016-10-15
We have developed a novel hydroxyapatite (HAp)-coated double-network (DN) hydrogel (HAp/DN gel). The purpose of this study was to determine details of the cell and tissue responses around the implanted HAp/DN gel and to determine how quickly and strongly the HAp/DN gel bonds to the bone in a rabbit osteochondral defect model. Immature osteoid tissue was formed in the space between the HAp/DN gel and the bone at 2weeks, and the osteoid tissue was mineralized at 4weeks. The push-out load of the HAp/DN gel averaged 37.54N and 42.15N at 4 and 12weeks, respectively, while the push-out load of the DN gel averaged less than 5N. The bonding area of the HAp/DN gel to the bone was above 80% by 4weeks, and above 90% at 12weeks. This study demonstrated that the HAp/DN gel enhanced osseointegration at an early stage after implantation. The presence of nanoscale structures in addition to osseointegration of HAp promoted osteoblast adhesion onto the surface of the HAp/DN gel. The HAp/DN gel has the potential to improve the implant-tissue interface in next-generation orthopaedic implants such as artificial cartilage. Recent studies have reported the development of various hydrogels that are sufficiently tough for application as soft supporting tissues. However, fixation of hydrogels on bone surfaces with appropriate strength is a great challenge. We have developed a novel, tough hydrogel hybridizing hydroxyapatite (HAp/DN gel), which is directly bondable to the bone. The present study demonstrated that the HAp/DN gel enhanced osseointegration in the early stage after implantation. The presence of nanoscale structures in addition to the osseointegration ability of hydroxyapatite promoted osteoblast adhesion onto the surface of the HAp/DN gel. The HAp/DN gel has the potential to improve the implant-tissue interface in next-generation orthopaedic implants such as artificial cartilage. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
A fully implantable rodent neural stimulator
Perry, D. W. J.; Grayden, D. B.; Shepherd, R. K.; Fallon, J. B.
2012-02-01
The ability to electrically stimulate neural and other excitable tissues in behaving experimental animals is invaluable for both the development of neural prostheses and basic neurological research. We developed a fully implantable neural stimulator that is able to deliver two channels of intra-cochlear electrical stimulation in the rat. It is powered via a novel omni-directional inductive link and includes an on-board microcontroller with integrated radio link, programmable current sources and switching circuitry to generate charge-balanced biphasic stimulation. We tested the implant in vivo and were able to elicit both neural and behavioural responses. The implants continued to function for up to five months in vivo. While targeted to cochlear stimulation, with appropriate electrode arrays the stimulator is well suited to stimulating other neurons within the peripheral or central nervous systems. Moreover, it includes significant on-board data acquisition and processing capabilities, which could potentially make it a useful platform for telemetry applications, where there is a need to chronically monitor physiological variables in unrestrained animals.
Pseudointercondylar notch sign: manifestation of osteochondritis dissecans of the trochlea
International Nuclear Information System (INIS)
Pruthi, Sumit; Parnell, Shawn E.; Thapa, Mahesh M.
2009-01-01
Osteochondritis dissecans (OCD) is an idiopathic condition affecting the articular epiphysis. Initially described in the knee, this entity affects several other parts of the body such as the talar dome, tarsal navicular, and femoral capital epiphysis. OCD of the elbow primarily involves the capitellum. OCD involving the trochlea has rarely been reported. We describe an unusual and interesting case of OCD affecting the trochlea, mimicking a pseudointercondylar notch. (orig.)
Role of computed tomography in evaluation of osteochondritis dissecans of the elbow joint
International Nuclear Information System (INIS)
Park, Byung Lyul; Kim, Jeong Eun; Jee, Keum Nahn; Park, Yang Hee
1995-01-01
To evaluate the role of CT in early detection, location, and extent of osteochondritis dissecans (OCD) of the elbow joint. We reviewed surgically proved 27 cases of 22 patients with osteochondritis dissecans in elbow joint retrospectively. We compared simple x-ray (elbow AP and lateral) with CT on the basis of staging of OCD of talus by simple x-ray. The frequency of location was as follows: fourteen cases of capitellum, 5 cases of olecranon tip, 5 cases of medial epicondyle, 2 cases of trochlea, and 1 case of olecranon base. Among the 4 cases of normal finding on simple x-ray, CT showed 1 case each of stage I, II, III and IV OCD and among the 8 cases of stage I on simple x-ray, CT showed 2 cases of stage I, 1 case of stage II, and 5 cases of stage III. Among the 3 cases of stage II on simple x-ray, CT showed 1 case of stage II and 2 cases of stage III. Among the 5 cases of stage III on simple x-ray, CT showed 1 case of stage II, 2 cases of stage III, and 2 cases of stage IV, but it was difficult to detect the presence or absence of attachment between the articular cartilage of mother bone and osteochondral fragment CT was more accurate than simple x-ray in detection of loose body. CT might be an useful imaging modality in early diagnosis of OCD and evaluation of its anatomic location and extent in elbow joint
Gold implant therapy of locomotory disorders in dogs - Case studies
Directory of Open Access Journals (Sweden)
Emilia Abrudean
2016-06-01
Full Text Available The case study was conducted between October and January 2015, on 7 dogs of different breeds and ages, which at clinical examination showed varying degrees of lameness. The dogs behavior and state of consciousness, their attitude in standing, decubitus and at walk and the presence of involuntary movements was assessed through inspection. Palpation was used to feel muscular tonus, local temperature and sensibility. Postural reactions were highlighted by carrying out forced positions of each limb, thus highlighting the proprioceptive sensitivity. By testing the spinal reflexes the reactions of the forelimbs and hind limbs were evaluated, seeking the state of normality, or the absence, diminution or exacerbation of these reflexes. Also, diagnostic imaging was performed consisting of simple radiographs, were performed for the cases that entered the clinic. In the case of digital X-rays, X-rays are passing through the subject being examined are filtered, then touch a plate of sensors able to convert signals generated into digital information with an image appear on the computer screen. Interpretation of results was done by assessing the degree of dysplasia, and the Norberg-Olson angle and stage. This study used digital radiography as imaging technique; the device was Rx-M EVO Fujifilm. On the basis of diagnostic imaging and computerized image, diagnosis was established for each case. The treatment protocol with gold implant was the same for all seven cases; the adopted procedure was the "Wiener" procedure, described by Kasper and Zohmann. The procedure began with establishing a set of points associated with the treatment of hip dysplasia, spondylosis, arthritis, and osteochondritis. For the therapeutic protocol to be performed correctly took the dogs were sedated. This was done with medetomidine hydrochloride (Dorbene vet, Pfizer, concentration 1 mg⁄ml, administered in a 0,1mg⁄kg body weight dose. The results were visible after a month from the
Generation of useful energy from process fluids using the biphase turbine
Helgeson, N. L.
1981-01-01
The six largest energy consuming industries in the United States were surveyed to determine the energy savings that could result from applying the Biphase turbine to industrial process streams. A national potential energy savings of 58 million barrels of oil per year (technical market) was identified. This energy is recoverable from flashing gas liquid process streams and is separate and distinct from exhaust gas waste heat recovery. The industries surveyed in this program were the petroleum chemical, primary metals, paper and pulp, stone-clay-glass, and food. It was required to determine the applicability of the Biphase turbine to flashing operations connected with process streams, to determine the energy changes associated with these flashes if carried out in a Biphase turbine, and to determine the suitability (technical and economical feasibility) of applying the Biphase turbine to these processes.
Wall, Corey R; Cook, Cristi R; Cook, James L
2015-01-01
Radiography, magnetic resonance imaging (MRI), and ultrasonography are commonly used for diagnosis of shoulder osteochondrosis and osteochondritis dissecans (OC/OCD) in dogs, however there is a lack of published information on the relative diagnostic sensitivities of these modalities. The purpose of this prospective study was to compare diagnostic sensitivities of these modalities for detecting shoulder OC/OCD in a group of dogs, using arthroscopy as the reference standard. Inclusion criteria were history and clinical findings consistent with osteochondrosis and/or osteochondritis dissecans involving at least one shoulder. With informed client consent, both shoulders for all included dogs were examined using standardized radiography, ultrasonography, MRI, and arthroscopy protocols. One of three veterinary surgeons recorded clinical and arthroscopic findings without knowledge of diagnostic imaging findings. One of two veterinary radiologists recorded diagnostic imaging findings without knowledge of clinical and arthroscopic findings. Eighteen client-owned dogs (n = 36 shoulders) met inclusion criteria. Diagnostic sensitivity, specificity, and accuracy (correct classification rate) values for detecting presence or absence of shoulder osteochondrosis/osteochondritis dissecans were as follows: radiography (88.5%, 90%, 88.9%), ultrasonography (92%, 60%, 82.6%), and MRI (96%, 88.9%, 94.4%). Odds of a correct diagnosis for MRI were 3.2 times more than ultrasonography and two times more than radiography. For MRI detection of lesions, the sagittal T2 or PD-FAT SAT sequences were considered to be most helpful. For radiographic detection of lesions, the additional supinated-mediolateral and pronated-mediolateral projections were considered to be most helpful. Findings from the current study support more evidence-based diagnostic imaging recommendations for dogs with clinically suspected shoulder osteochondrosis or osteochondritis dissecans. © 2014 American College of
Directory of Open Access Journals (Sweden)
Giavaresi Gianluca
2010-09-01
Full Text Available Abstract Background Current research aims to develop innovative approaches to improve chondral and osteochondral regeneration. The objective of this study was to investigate the regenerative potential of platelet-rich plasma (PRP to enhance the repair process of a collagen-hydroxyapatite scaffold in osteochondral defects in a sheep model. Methods PRP was added to a new, multi-layer gradient, nanocomposite scaffold that was obtained by nucleating collagen fibrils with hydroxyapatite nanoparticles. Twenty-four osteochondral lesions were created in sheep femoral condyles. The animals were randomised to three treatment groups: scaffold, scaffold loaded with autologous PRP, and empty defect (control. The animals were sacrificed and evaluated six months after surgery. Results Gross evaluation and histology of the specimens showed good integration of the chondral surface in both treatment groups. Significantly better bone regeneration and cartilage surface reconstruction were observed in the group treated with the scaffold alone. Incomplete bone regeneration and irregular cartilage surface integration were observed in the group treated with the scaffold where PRP was added. In the control group, no bone and cartilage defect healing occurred; defects were filled with fibrous tissue. Quantitative macroscopic and histological score evaluations confirmed the qualitative trends observed. Conclusions The hydroxyapatite-collagen scaffold enhanced osteochondral lesion repair, but the combination with platelet growth factors did not have an additive effect; on the contrary, PRP administration had a negative effect on the results obtained by disturbing the regenerative process. In the scaffold + PRP group, highly amorphous cartilaginous repair tissue and poorly spatially organised underlying bone tissue were found.
Lin, Yang; Lewallen, Eric A.; Camilleri, Emily T.; Bonin, Carolina A.; Jones, Dakota L.; Dudakovic, Amel; Galeano-Garces, Catalina; Wang, Wei; Karperien, Marcel J.; Larson, Annalise N.; Dahm, Diane L.; Stuart, Michael J.; Levy, Bruce A.; Smith, Jay; Ryssman, Daniel B.; Westendorf, Jennifer J.; Im, Hee-Jeong; van Wijnen, Andre J.; Riester, Scott M.; Krych, Aaron J.
2016-01-01
Preservation of osteochondral allografts used for transplantation is critical to ensure favorable outcomes for patients after surgical treatment of cartilage defects. To study the biological effects of protocols currently used for cartilage storage, we investigated differences in gene expression
Contemporary guided bone regeneration therapy for unaesthetic anterior peri-implantitis case
Directory of Open Access Journals (Sweden)
Benso Sulijaya
2016-12-01
Full Text Available Background: Dental implant is one of an alternative solutions reconstruction therapy for missing teeth. Complication of dental implant could occurs and leading to implant failure. In order to restore the complication, surgical treatment with guided bone regeneration (GBR is indicated. The potential use of bone substitutes is widely known to be able to regenerate the bone surrounding the implant and maintain bone volume. Purpose: The study aimed to demonstrate the effectiveness of implant-bone fully coverage by using sandwich technique of biphasic calcium phosphate (BCP and demineralized freeze-dried bone allografts (DFDBA bone substitutes combined with collagen resorbable membrane. Case: A 24-year-old male came with diagnosis of peri-implantitis on implant #11. Clinical finding indicated that implant thread was exposed on the labial aspect. Case management: After initial therapy including oral hygiene improvement performed, an operator did a contemporary GBR to correct the defect. Bone graft materials used were 40% β-tri calcium phosphate (β-TCP-60% hydroxyapatite (HA on the outer layer and DFDBA on the inner layer of the defect. Resorbable collagen membrane was used to cover the graft. Conclusion: GBR with sandwich technique could serve as one of the treatment choices for correcting an exposed anterior implant that would enhance the successful aesthetic outcome.
Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint
International Nuclear Information System (INIS)
Becce, Fabio; Mouhsine, Elyazid; Mosimann, Pascal John; Anaye, Anass; Letovanec, Igor; Theumann, Nicolas
2012-01-01
Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography—guided retrograde drilling and debridement.
Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint
Energy Technology Data Exchange (ETDEWEB)
Becce, Fabio, E-mail: fabio.becce@chuv.ch [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (Switzerland); Mouhsine, Elyazid [Clinique Hirslanden Bois-Cerf, Department of Orthopaedic Surgery (Switzerland); Mosimann, Pascal John; Anaye, Anass [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (Switzerland); Letovanec, Igor [University Institute of Pathology, Centre Hospitalier Universitaire Vaudois (Switzerland); Theumann, Nicolas [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (Switzerland)
2012-08-15
Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography-guided retrograde drilling and debridement.
Analysis of a biphase-based servo format for hard-disk drives
Makinwa, K.A.A.; Bergmans, J.W.M.; Voorman, J.O.
2000-01-01
Biphase modulation in an embedded-servo format for hard-disk drives is investigated. It is shown that for biphase, at the low linear densities typical of servo information, near-maximum-likelihood performance can be attained by a simple bit detector consisting of a full-response linear equalizer and
Alpha alumina synthesis by laser treatment of bi-phasic nanowires
Energy Technology Data Exchange (ETDEWEB)
Aktas, Cenk, E-mail: cenk.aktas@inm-gmbh.de [Leibniz Institute for New Materials, D2 2 Campus, 66123 Saarbrücken (Germany); Lee, Juseok; Míro, Marina Martinez [Leibniz Institute for New Materials, D2 2 Campus, 66123 Saarbrücken (Germany); Barnoush, Afrooz [Norwegian University of Science and Technology, Trondheim (Norway); Saarland University, D2 2 Campus, 66123 Saarbrücken (Germany); Veith, Michael [Leibniz Institute for New Materials, D2 2 Campus, 66123 Saarbrücken (Germany)
2013-08-01
Al/Al{sub 2}O{sub 3} bi-phasic nanowires (Al-core/Al{sub 2}O{sub 3} shell) are prepared by chemical vapor deposition (CVD) using single source precursor (SSP) approach. Such bi-phasic nanostructures were heat-treated using an argon laser operating at visible wavelengths. Al core seems to act as an active binder, which might decrease the inhomogeneous heating and thermal gradients. Nanoindentation method is used to estimate the hardness of the laser treated surfaces. Hardness values and pop-in behaviour in loading-curve indicate a formation of α-Al{sub 2}O{sub 3} with very low defect density. It is believed that Al/Al{sub 2}O{sub 3} bi-phasic layers exhibit a dynamic change by transforming into alumina after the laser irradiation and this leads to alteration of the optical absorption especially in the visible wavelength region. Following the full transformation to alumina, the surface reflects back the laser light which hinders inhomogeneous and excessive heating. In this context, laser treatment of Al/Al{sub 2}O{sub 3} bi-phasic nanowires provides a controlled sintering process which can open up various applications in different fields.
Effect of load on the repair of osteochondral defects using a porous polymer scaffold
Hannink, G.J.; de Mulder, E.L.; Tienen, T.G. van; Buma, P.
2012-01-01
The aim of the present study was to evaluate if a porous polymer scaffold, currently used for partial meniscal replacement in clinical practice, could initiate regeneration and repair of osteochondral defects, and if regeneration and repair were related to mechanical stimulation. Two equally sized
Steinmetz, Neven J; Aisenbrey, Elizabeth A; Westbrook, Kristofer K; Qi, H Jerry; Bryant, Stephanie J
2015-07-01
A bioinspired multi-layer hydrogel was developed for the encapsulation of human mesenchymal stem cells (hMSCs) as a platform for osteochondral tissue engineering. The spatial presentation of biochemical cues, via incorporation of extracellular matrix analogs, and mechanical cues, via both hydrogel crosslink density and externally applied mechanical loads, were characterized in each layer. A simple sequential photopolymerization method was employed to form stable poly(ethylene glycol)-based hydrogels with a soft cartilage-like layer of chondroitin sulfate and low RGD concentrations, a stiff bone-like layer with high RGD concentrations, and an intermediate interfacial layer. Under a compressive load, the variation in hydrogel stiffness within each layer produced high strains in the soft cartilage-like layer, low strains in the stiff bone-like layer, and moderate strains in the interfacial layer. When hMSC-laden hydrogels were cultured statically in osteochondral differentiation media, the local biochemical and matrix stiffness cues were not sufficient to spatially guide hMSC differentiation after 21 days. However dynamic mechanical stimulation led to differentially high expression of collagens with collagen II in the cartilage-like layer, collagen X in the interfacial layer and collagen I in the bone-like layer and mineral deposits localized to the bone layer. Overall, these findings point to external mechanical stimulation as a potent regulator of hMSC differentiation toward osteochondral cellular phenotypes. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Directory of Open Access Journals (Sweden)
L.S. Iamaguti
2013-02-01
Full Text Available Padronizou-se a metodologia para cultura de condrócitos em cães e avaliou-se seu implante em lesões osteocondrais, utilizando-se a membrana biossintética de celulose (MBC como revestimento. Dez cães, adultos e clinicamente sadios, foram submetidos à artrotomia das articulações fêmoro-tíbio-patelares. Defeitos de 4mm de diâmetro e profundidade foram induzidos no sulco troclear de ambos os membros. MBC foi aplicada na base e na superfície das lesões. Os defeitos do membro direito foram preenchidos com condrócitos homólogos cultivados formando o grupo-tratado (GT; os do membro esquerdo, sem implante celular, foram designados grupo-controle (GC. A evolução pós-operatória foi analisada com especial interesse nos processos de reparação da lesão, por meio de histomorfometria e imuno-histoquímica para colágeno tipo II e sulfato de condroitina. A cultura de condrócitos homólogos apresentou alta densidade e taxa de viabilidade. Observou-se integridade do tecido neoformado com a cartilagem adjacente na avaliação histológica, em ambos os grupos. Na imuno-histoquímica, verificou-se predomínio de colágeno tipo II no GT. Morfometricamente, não houve diferença significativa entre o tecido fibroso e o fibrocartilaginoso entre os grupos. A cultura de condrócitos homólogos de cães foi exequível. O tecido neoformado apresentou qualidade discretamente superior associado ao implante homólogo de condrócitos, contudo não promoveu reparação por cartilagem hialina.The aim of the study is to standardize the methodology to achieve canine chondrocytes culture, and evaluate its implant on osteochondral defects made in the femoral trochlear sulcus of dogs, using the cellulose biosynthetic membrane (CBM as coating. Ten healthy adult dogs without locomotor disorders were used. All animals were submitted to arthrotomy of stifle joints and defects of four millimeters in diameter x four millimeters deep were done in the femoral trochlear
Chondrocyte survival in osteochondral transplant cylinders depends on the harvesting technique.
Hafke, Benedikt; Petri, Maximilian; Suero, Eduardo; Neunaber, Claudia; Kwisda, Sebastian; Krettek, Christian; Jagodzinski, Michael; Omar, Mohamed
2016-07-01
In autologous osteochondral transplantation, the edges of the harvested plug are particularly susceptible to mechanical or thermal damage to the chondrocytes. We hypothesised that the applied harvesting device has an impact on chondrocyte vitality. Both knees of five blackhead sheep (ten knees) underwent open osteochondral plug harvesting with three different circular harvesting devices (osteoarticular transfer system harvester [OATS; diameter 8 mm; Arthrex, Munich, Germany], diamond cutter [DC; diameter 8.35 mm; Karl Storz, Tuttlingen, Germany] and hollow reamer with cutting crown [HRCC; diameter 7 mm; Dannoritzer, Tuttlingen, Germany]) from distinctly assigned anatomical sites of the knee joint. The rotary cutters (DC and HRCC) were either used with (+) or without cooling (-). Surgical cuts of the cartilage with a scalpel blade were chosen as control method. After cryotomy cutting, chondrocyte vitality was assessed using fluorescence microscopy and a Live/Dead assay. There were distinct patterns of chondrocyte vitality, with reproducible accumulations of dead chondrocytes along the harvesting edge. No statistical difference in chondrocyte survivorship was seen between the OATS technique and the control method, or between the HRCC+ technique and the control method (P > 0.05). The DC+, HRCC- and DC- techniques yielded significantly lower chondrocyte survival rates compared with the control method (P vitality.
Metal separations using aqueous biphasic partitioning systems
International Nuclear Information System (INIS)
Chaiko, D.J.; Zaslavsky, B.; Rollins, A.N.; Vojta, Y.; Gartelmann, J.; Mego, W.
1996-01-01
Aqueous biphasic extraction (ABE) processes offer the potential for low-cost, highly selective separations. This countercurrent extraction technique involves selective partitioning of either dissolved solutes or ultrafine particulates between two immiscible aqueous phases. The extraction systems that the authors have studied are generated by combining an aqueous salt solution with an aqueous polymer solution. They have examined a wide range of applications for ABE, including the treatment of solid and liquid nuclear wastes, decontamination of soils, and processing of mineral ores. They have also conducted fundamental studies of solution microstructure using small angle neutron scattering (SANS). In this report they review the physicochemical fundamentals of aqueous biphase formation and discuss the development and scaleup of ABE processes for environmental remediation
Evaluation of the finite element software ABAQUS for biomechanical modelling of biphasic tissues.
Wu, J Z; Herzog, W; Epstein, M
1998-02-01
The biphasic cartilage model proposed by Mow et al. (1980) has proven successful to capture the essential mechanical features of articular cartilage. In order to analyse the joint contact mechanics in real, anatomical joints, the cartilage model needs to be implemented into a suitable finite element code to approximate the irregular surface geometries of such joints. However, systematic and extensive evaluation of the capacity of commercial software for modelling the contact mechanics with biphasic cartilage layers has not been made. This research was aimed at evaluating the commercial finite element software ABAQUS for analysing biphasic soft tissues. The solutions obtained using ABAQUS were compared with those obtained using other finite element models and analytical solutions for three numerical tests: an unconfined indentation test, a test with the contact of a spherical cartilage surface with a rigid plate, and an axi-symmetric joint contact test. It was concluded that the biphasic cartilage model can be implemented into the commercial finite element software ABAQUS to analyse practical joint contact problems with biphasic articular cartilage layers.
Chang, Nai-Jen; Lin, Chih-Chan; Shie, Ming-You; Yeh, Ming-Long; Li, Chien-Feng; Liang, Peir-In; Lee, Kuan-Wei; Shen, Pei-Hsun; Chu, Chih-Jou
2015-12-01
The regeneration of hyaline cartilage remains clinically challenging. Here, we evaluated the therapeutic effects of using cell-free porous poly(lactic-co-glycolic acid) (PLGA) graft implants (PGIs) along with early loading exercise to repair a full-thickness osteochondral defect. Rabbits were randomly allocated to a treadmill exercise (TRE) group or a sedentary (SED) group and were prepared as either a PGI model or an empty defect (ED) model. TRE was performed as a short-term loading exercise; SED was physical inactivity in a free cage. The knees were evaluated at 6 and 12 weeks after surgery. At the end of testing, none of the knees developed synovitis, formed osteophytes, or became infected. Macroscopically, the PGI-TRE group regenerated a smooth articular surface, with transparent new hyaline-like tissue soundly integrated with the neighboring cartilage, but the other groups remained distinct at the margins with fibrous or opaque tissues. In a micro-CT analysis, the synthesized bone volume/tissue volume (BV/TV) was significantly higher in the PGI-TRE group, which also had integrating architecture in the regeneration site. The thickness of the trabecular (subchondral) bone was improved in all groups from 6 to 12 weeks. Histologically, remarkable differences in the cartilage regeneration were visible. At week 6, compared with SED groups, the TRE groups manifested modest inflammatory cells with pro-inflammatory cytokines (i.e., TNF-α and IL-6), improved collagen alignment and higher glycosaminoglycan (GAG) content, particularly in the PGI-TRE group. At week 12, the PGI-TRE group had the best regeneration outcomes, showing the formation of hyaline-like cartilage, the development of columnar rounded chondrocytes that expressed enriched levels of collagen type II and GAG, and functionalized trabecular bone with osteocytes. In summary, the combination of implanting cell-free PLGA and performing an early loading exercise can significantly promote the full
Shimizu, Manabu; Matsumoto, Taro; Kikuta, Shinsuke; Ohtaki, Munenori; Kano, Koichiro; Taniguchi, Hiroaki; Saito, Shu; Nagaoka, Masahiro; Tokuhashi, Yasuaki
2018-03-20
Mature adipocyte-derived dedifferentiated fat (DFAT) cells possesses the ability to proliferate effectively and the potential to differentiate into multiple linages of mesenchymal tissue; similar to adipose-derived stem cells (ASCs). The purpose of this study is to examine the effects of DFAT cell transplantation on cartilage repair in a rat model of osteochondral defects. Full-thickness osteochondral defects were created in the knees of Sprague-Dawley rats bilaterally. Cartilage-like micromass pellets were prepared from green fluorescent protein (GFP)-labeled rat DFAT cells and subsequently transplanted into the affected right knee of these rats. Defects in the left knee were used as a control. Macroscopic and microscopic changes of treated and control defects were evaluated up to 12 weeks post-treatment with DFAT cells. To observe the transplanted cells, sectioned femurs were immunostained for GFP and type II collagen. DFAT cells formed micromass pellets expressing characteristics of immature cartilage in vitro. In the DFAT cell-transplanted limbs, the defects were completely filled with white micromass pellets as early as 2 weeks post-treatment. These limbs became smooth at 4 weeks. Conversely, the defects in the control limbs were still not repaired by 4 weeks. Macroscopic ICRS scores at 2 and 4 weeks were significantly higher in the DFAT cells-transplanted limbs compared to those of the control limbs. The modified O'Driscol histological scores for the DFAT cell-transplanted limbs were significantly higher than those of the control limbs at corresponding time points. GFP-positive DAFT cells were detected in the transplanted area at 2 weeks but hardly visible at 12 weeks post-operation. Transplantation of DFAT cell-derived micromass pellets contribute to cartilage repair in a rat osteochondral defect model. DFAT cell transplantation may be a viable therapeutic strategy for the repair of osteochondral injuries. Copyright © 2018 The Authors. Published by
Nosewicz, Tomasz L.; Beerekamp, M. Suzan H.; de Muinck Keizer, Robert-Jan O.; Schepers, Tim; Maas, Mario; Niek van Dijk, C.; Goslings, J. Carel
2016-01-01
Osteochondral lesions (OCLs) associated with ankle fracture correlate with unfavorable outcome. The goals of this study were to detect OCLs following ankle fracture, to associate fracture type to OCLs and to investigate whether OCLs affect clinical outcome. 100 ankle fractures requiring operative
Briggs, Dustin T; Sadr, Kamran N; Pulido, Pamela A; Bugbee, William D
2015-10-01
To assess the outcome of osteochondral allograft (OCA) transplantation as the primary treatment for cartilage injury in patients with no previous surgical treatment. Case series. Patients were identified in our outcomes database. Patients undergoing primary OCA transplantation with no prior surgical treatment and a minimum of 2 years follow-up were selected. Pain and function were evaluated preoperatively and postoperatively. Patient satisfaction was assessed. Reoperations following OCA transplantation were captured. Failure was defined as revision OCA or conversion to arthroplasty. Fifty-five patients (61 knees) were included in the analysis. The study consisted of 30 males and 25 females (mean age = 32.9 years; range = 15.7-67.8 years). The most common diagnoses for the OCA transplantation were osteochondritis dissecans (44.3%) and avascular necrosis (31.1%). Pain and function improved preoperatively to postoperatively on all outcome scales (P OCA survivorship was 89.5% at 5 years and 74.7% at 10 years. At latest follow-up (mean = 7.6 years; range = 1.9-22.6 years), OCA remained in situ in 50 knees (82%). Eighteen knees (29.5%) had further surgery; 11 OCA failures and 7 other surgical procedure(s). Of the failed knees (mean time to failure = 3.5 years; range = 0.5-13.7 years), 8 were converted to arthroplasty, 2 had OCA revisions, and 1 had a patellectomy. OCA transplantation is an acceptable primary treatment method for some chondral and osteochondral defects of the knee. Failure of previous treatment(s) is not a prerequisite for OCA transplantation.
Energy Technology Data Exchange (ETDEWEB)
Versteylen, R.J.; Zwemmer, A.; Lorie, C.A.M.; Schuur, K.H.
1988-09-01
Two families are described which appear to contain examples of multiple epiphyseal dysplasia. In both families a striking incidence of severe osteochondritis of the knees was encountered. It is suggested that this was caused by the fragmented and maldeveloped epiphyses characteristic of epiphyseal dysplasia.
Lu, S.; Lam, J.; Trachtenberg, J.E.; Lee, E.J.; Seyednejad, H.; van den Beucken, J.J.; Tabata, Y.; Wong, M.E.; Jansen, J.A.; Mikos, A.G.; Kasper, F.K.
2014-01-01
The present work investigated the use of biodegradable hydrogel composite scaffolds, based on the macromer oligo(poly(ethylene glycol) fumarate) (OPF), to deliver growth factors for the repair of osteochondral tissue in a rabbit model. In particular, bilayered OPF composites were used to mimic the
Cognault, J; Seurat, O; Chaussard, C; Ionescu, S; Saragaglia, D
2015-05-01
Autogenous osteochondral mosaicplasty is the most common cartilage restoration technique in standard clinical practice. The purpose of this study was to evaluate the return to sports 9 years after mosaicplasty of the femoral condyles. The long-term results of an osteochondral autograft show that patients can regain their pre-injury activity level. This study is based on a series of 25 patients with a mean age of 28.9 years (range, 16-44 years) who had stage 3 or 4 chondral lesions of the femoral condyles (according to the ICRS or ICRS-OCD scores). The origin of the lesion was osteochondritis dissecans (13 knees), osteochondral fracture sequelae (ten knees), or aseptic osteonecrosis (two knees). The average size of the lesion was 2.11 ± 0.9 cm(2). Ten patients (40%) had an associated procedure during the osteochondral autograft. The patients were assessed clinically (IKDC and Lysholm-Tegner scores) and radiographically by a reviewer independent of the team of operators. All patients were re-examined at a mean follow-up of 9 years (range, 6-15 years), with 84% satisfied or very satisfied with the procedure. The average IKDC was 74.5 ± 18.5 points. The average Lysholm score was 87.3 ± 11.6 points. The average Tegner score ranged from 6.35 ± 1.53 points prior to surgery to 5.60 ± 1.64 points after surgery (P = 0.001). The average loss was 0.64 points for patients whose presurgery Tegner score was greater than or equal to 7 (P = 0.019) and 0.3 points if lower than 7. The radiologic evaluation of 21 patients showed complete osteointegration of the grafts in 90% of cases. The results of the femoral condyle mosaic autografts are satisfactory, a mean of 9 years after surgery. The most active patients lowered their activity level while the more sedentary did not have to adapt their lifestyle. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Osteochondritis dissecans (OCD), an endoplasmic reticulum storage disease?
DEFF Research Database (Denmark)
Skagen, Peter Storgaard; Horn, T; Kruse, H A
2011-01-01
Osteochondritis dissecans (OCD) fragments, cartilage and blood from four patients were used for morphological and molecular analysis. Controls included articular cartilage and blood samples from healthy individuals. Light microscopy and transmission electron microscopy (TEM) showed abnormalities...... in chondrocytes and extracellular matrix of cartilage from OCD patients. Abnormal type II collagen heterofibrils in "bundles" and chondrocytes with abnormal accumulation of matrix proteins in distended rough endoplasmic reticulum were typical findings. Further, Von Kossa staining and TEM showed empty lacunae...... polymorphism was found within the COL2A1 gene for one patient. We suggest that OCD lesions are caused by an alteration in chondrocyte matrix synthesis causing an endoplasmic reticulum storage disease phenotype, which disturbs or abrupts endochondral ossification....
A re-examination of the biphasic theory of skeletal muscle growth.
Levine, A S; Hegarty, P V
1977-01-01
Because of the importance of fibre diameter measurements it was decided to re-evaluate the biphasic theory of skeletal muscle growth and development. This theory proposes an initial memophasic distribution of muscle fibres which changes to a biphasic distribution during development. The theory is based on observations made on certain muscles in mice, where two distinct populations of fibre diameters (20 and 40 micronm) contribute to the biphasic distribution. In the present investigation corss sections of frozen biceps brachii of mice in rigor mortis were examined. The rigor state was used to avoid complications produced by thaw-rigor contraction. The diameters of the outermost and innermost fibres were found to be significantly different. However, if the outer and inner fibres were combined to form one group, no significant difference between this group and other random groups was found. The distributions of all groups were monophasic. The diameters of isolated fibres from mice and rats also displayed a monophasic distribution. This evidence leads to the conclusion that the biphasic theory of muscle growth is untenable. Some of the variables which may occur in fibre size and shape are discussed. Images Fig. 1 PMID:858691
Three dimensional biphasic calcium phosphate nanocomposites for load bearing bioactive bone grafts
Energy Technology Data Exchange (ETDEWEB)
Garai, Subhadra, E-mail: subha@nmlindia.org; Sinha, Arvind
2016-02-01
Mimicking matrix mediated bio-mineralization process, three dimensional blocks of biphasic calcium phosphate (BCP, hydroxyapatite (HA) and β-tricalcium phosphate (TCP)) nanocomposites, having three different stoichiometries have been synthesized for possible application as load bearing synthetic bone graft or scaffolds. Biphasic blocks with three weight ratios of 20:80, 25:75 and 30:70 of HA and TCP respectively have been synthesized. Detailed structural and chemical characterization of the samples revealed a strong dependence of porosity and mechanical properties on the stoichiometry of biphasic blocks. Effect of physiological medium on the microstructure and mechanical properties of the three different blocks has also been studied. Bioactivity of the BCP block, exhibiting highest compressive strength in air as well as in physiological medium, has been evaluated through adhesion, proliferation and differentiation of mesenchymal stem cells using different markers. - Highlights: • Developed a process for the synthesis of load bearing 3d- biphasic nanocomposites. • Synthesized nanocomposites exhibited in vitro osteoconductivity and osteoinductivity for bone marrow mesenchymal cells. • Developed process is a matrix mediated biomimetic one.
Additive manufacturing for in situ repair of osteochondral defects
International Nuclear Information System (INIS)
Cohen, Daniel L; Lipton, Jeffrey I; Bonassar, Lawrence J; Lipson, Hod
2010-01-01
Tissue engineering holds great promise for injury repair and replacement of defective body parts. While a number of techniques exist for creating living biological constructs in vitro, none have been demonstrated for in situ repair. Using novel geometric feedback-based approaches and through development of appropriate printing-material combinations, we demonstrate the in situ repair of both chondral and osteochondral defects that mimic naturally occurring pathologies. A calf femur was mounted in a custom jig and held within a robocasting-based additive manufacturing (AM) system. Two defects were induced: one a cartilage-only representation of a grade IV chondral lesion and the other a two-material bone and cartilage fracture of the femoral condyle. Alginate hydrogel was used for the repair of cartilage; a novel formulation of demineralized bone matrix was used for bone repair. Repair prints for both defects had mean surface errors less than 0.1 mm. For the chondral defect, 42.8 ± 2.6% of the surface points had errors that were within a clinically acceptable error range; however, with 1 mm path planning shift, an estimated ∼75% of surface points could likely fall within the benchmark envelope. For the osteochondral defect, 83.6 ± 2.7% of surface points had errors that were within clinically acceptable limits. In addition to implications for minimally invasive AM-based clinical treatments, these proof-of-concept prints are some of the only in situ demonstrations to-date, wherein the substrate geometry was unknown a priori. The work presented herein demonstrates in situ AM, suggests potential biomedical applications and also explores in situ-specific issues, including geometric feedback, material selection and novel path planning techniques.
Arakaki, Kazunobu; Kitamura, Nobuto; Kurokawa, Takayuki; Onodera, Shin; Kanaya, Fuminori; Gong, Jian-Ping; Yasuda, Kazunori
2011-02-01
We have recently discovered that spontaneous hyaline cartilage regeneration can be induced in an osteochondral defect in the rabbit, when we implant a novel double-network (DN) gel plug at the bottom of the defect. To clarify whether joint immobilization inhibits the spontaneous hyaline cartilage regeneration, we conducted this study with 20 rabbits. At 4 or 12 weeks after surgery, the defect in the mobile knees was filled with a sufficient volume of the hyaline cartilage tissue rich in proteoglycan and type-2 collagen, while no cartilage tissues were observed in the defect in the immobilized knees. Type-2 collagen, Aggrecan, and SOX9 mRNAs were expressed only in the mobile knees at each period. This study demonstrated that joint immobilization significantly inhibits the spontaneous hyaline cartilage regeneration induced by the DN gel implantation. This fact suggested that the mechanical environment is one of the significant factors to induce this phenomenon.
Kadarmideen, H.N.; Janss, L.L.G.
2005-01-01
Bayesian segregation analyses were used to investigate the mode of inheritance of osteochondral lesions (osteochondrosis, OC) in pigs. Data consisted of 1163 animals with OC and their pedigrees included 2891 animals. Mixed-inheritance threshold models (MITM) and several variants of MITM, in
Pareek, A.; Sanders, T. L.; Wu, I. T.; Larson, D. R.; Saris, D. B.F.; Krych, A.J.
2017-01-01
Objective: To (1) define population-based incidence of knee Osteochondritis dissecans (OCD) lesions using the population of Olmsted County, (2) examine trends over time, and (3) evaluate rate of surgical management over time. Method: Study population included 302 individuals who were diagnosed with
Preparation and Characterization of Apatitic Biphasic Calcium Phosphate
International Nuclear Information System (INIS)
Thin Thin Nwe; Kyaw Naing; Khin Mar Tun; Nyunt Wynn
2005-09-01
The apatitic biphasic calcium phosphate (ABcp) consisting of hydroxyapatite (HA) and -tricalcium phosphate ( -Tcp) has been prepared by precipitation technique using slaked lime and orthophosphoric acid. The X-ray diffraction analysis of the product I (hydroxyapatite) revealed that ABcp was partially crystalline state. However, on heating at 800 C for 8 hrs, XRD pattern indicated a perfectly crystalline form of ABcp. This observation was supported by FT-IR measurement. The change in morphology regarding in the functional nature was infered by the shift in the FT-IR frequency. The optimization of the apatitic biphasic calcium phosphate was done by the variation of disodium hydrogen phosphate concentration, setting time, hardening time as well as compressive strength. The perpared cement may be used as an artificial substitution bone
The standard biphasic-contrast examination of the stomach and duodenum
International Nuclear Information System (INIS)
Op den Orth, J.O.
1979-01-01
A standard examination has been developed, called biphasic, because it combines the advantages of positive-contrast and double-contrast techniques. The theoretical background and technique of this examination are described and the basic interpretation of double-contrast studies stated. General remarks on the results and on the complementary role of radiological examination and endoscopy are included. A quantitative study of standard biphasic-contrast examinations in patients over a period of 3 years is presented. Finally a radiological atlas of common lesions of the stomach and duodenum is given. (C.F.)
Biphasic decay of the Ca transient results from increased sarcoplasmic reticulum Ca leak
Sankaranarayanan, Rajiv; Li, Yatong; Greensmith, David J.; Eisner, David A.
2016-01-01
Key points Ca leak from the sarcoplasmic reticulum through the ryanodine receptor (RyR) reduces the amplitude of the Ca transient and slows its rate of decay.In the presence of β‐adrenergic stimulation, RyR‐mediated Ca leak produces a biphasic decay of the Ca transient with a fast early phase and a slow late phase.Two forms of Ca leak have been studied, Ca‐sensitising (induced by caffeine) and non‐sensitising (induced by ryanodine) and both induce biphasic decay of the Ca transient.Only Ca‐sensitising leak can be reversed by traditional RyR inhibitors such as tetracaine.Ca leak can also induce Ca waves. At low levels of leak, waves occur. As leak is increased, first biphasic decay and then slowed monophasic decay is seen. The level of leak has major effects on the shape of the Ca transient. Abstract In heart failure, a reduction in Ca transient amplitude and contractile dysfunction can by caused by Ca leak through the sarcoplasmic reticulum (SR) Ca channel (ryanodine receptor, RyR) and/or decreased activity of the SR Ca ATPase (SERCA). We have characterised the effects of two forms of Ca leak (Ca‐sensitising and non‐sensitising) on calcium cycling and compared with those of SERCA inhibition. We measured [Ca2+]i with fluo‐3 in voltage‐clamped rat ventricular myocytes. Increasing SR leak with either caffeine (to sensitise the RyR to Ca activation) or ryanodine (non‐sensitising) had similar effects to SERCA inhibition: decreased systolic [Ca2+]i, increased diastolic [Ca2+]i and slowed decay. However, in the presence of isoproterenol, leak produced a biphasic decay of the Ca transient in the majority of cells while SERCA inhibition produced monophasic decay. Tetracaine reversed the effects of caffeine but not of ryanodine. When caffeine (1 mmol l−1) was added to a cell which displayed Ca waves, the wave frequency initially increased before waves disappeared and biphasic decay developed. Eventually (at higher caffeine concentrations), the
Energy Technology Data Exchange (ETDEWEB)
He, Fupo, E-mail: fphebm@126.com [School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou 510006 (China); Ren, Weiwei [School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou 510006 (China); Tian, Xiumei [Department of Biomedical Engineering, School of Basic Sciences, Guangzhou Medical University, Guangzhou 510182 (China); Liu, Wei; Wu, Shanghua [School of Electromechanical Engineering, Guangdong University of Technology, Guangzhou 510006 (China); Chen, Xiaoming, E-mail: xmchenw@126.com [Department of Biomedical Engineering, School of Basic Sciences, Guangzhou Medical University, Guangzhou 510182 (China)
2016-07-01
In a previous study, robust calcium carbonate composite ceramics (CC/PG) were prepared by using phosphate-based glass (PG) as an additive, which showed good cell response. In the present study the in vivo response of porous CC/PG was compared to that of porous biphasic calcium phosphate ceramics (BCP), using a rabbit femoral critical-size grafting model. The materials degradation and bone formation processes were evaluated by general observation, X-ray radiography, micro-computed tomography, and histological examination. The results demonstrated excellent biocompatibility and osteoconductivity, and progressive degradation of CC/PG and BCP. Although the in vitro degradation rate of CC/PG was distinctly faster than that of BCP, at 4 week post-implantation, the bone generation and material degradation of CC/PG were less than those of BCP. Nevertheless, at postoperative week 8, the increment of bone formation and material degradation of CC/PG was pronouncedly larger than that of BCP. These results show that CC/PG is a potential resorbable bone graft aside from the traditional synthetic ones. - Highlights: • A calcium carbonate composite ceramic (CC/PG) was acquired. • The in vivo response of CC/PG and biphasic calcium phosphate (BCP) was compared. • CC/PG showed faster in vitro degradation rate compared to BCP. • CC/PG showed less in vivo degradation and bone formation than BCP at week 4. • CC/PG had larger increment of degradation and bone formation than BCP at week 8.
International Nuclear Information System (INIS)
He, Fupo; Ren, Weiwei; Tian, Xiumei; Liu, Wei; Wu, Shanghua; Chen, Xiaoming
2016-01-01
In a previous study, robust calcium carbonate composite ceramics (CC/PG) were prepared by using phosphate-based glass (PG) as an additive, which showed good cell response. In the present study the in vivo response of porous CC/PG was compared to that of porous biphasic calcium phosphate ceramics (BCP), using a rabbit femoral critical-size grafting model. The materials degradation and bone formation processes were evaluated by general observation, X-ray radiography, micro-computed tomography, and histological examination. The results demonstrated excellent biocompatibility and osteoconductivity, and progressive degradation of CC/PG and BCP. Although the in vitro degradation rate of CC/PG was distinctly faster than that of BCP, at 4 week post-implantation, the bone generation and material degradation of CC/PG were less than those of BCP. Nevertheless, at postoperative week 8, the increment of bone formation and material degradation of CC/PG was pronouncedly larger than that of BCP. These results show that CC/PG is a potential resorbable bone graft aside from the traditional synthetic ones. - Highlights: • A calcium carbonate composite ceramic (CC/PG) was acquired. • The in vivo response of CC/PG and biphasic calcium phosphate (BCP) was compared. • CC/PG showed faster in vitro degradation rate compared to BCP. • CC/PG showed less in vivo degradation and bone formation than BCP at week 4. • CC/PG had larger increment of degradation and bone formation than BCP at week 8.
van Eekeren, Inge C. M.; Reilingh, Mikel L.; van Dijk, C. Niek
2012-01-01
An osteochondral defect (OD) is a lesion involving the articular cartilage and the underlying subchondral bone. ODs of the talus can severely impact on the quality of life of patients, who are usually young and athletic. The primary treatment for ODs that are too small for fixation, consists of
[Arthroscopic treatment of chondral lesions of the ankle joint. Evidence-based therapy].
Thomas, M; Jordan, M; Hamborg-Petersen, E
2016-02-01
Ankle sprains are the most relevant injuries of the lower extremities and can lead to damage to ligaments and osteochondral lesions. Up to 50 % of patients with a sprained ankle later develop a lesion of the cartilage in the ankle joint or an osteochondral lesion of the talus. This can lead to osteoarthritis of the injured ankle joint. Spontaneous healing is possible in all age groups in cases of a bone bruise in the subchondral bone but in isolated chondral injuries is only useful in pediatric patients. In many cases chondral and osteochondral injuries lead to increasing demarcation of the affected area and can result in progressive degeneration of the joint if not recognized in time. There also exist a certain number of osteochondral changes of the articular surface of the talus without any history of relevant trauma, which are collectively grouped under the term osteochondrosis dissecans. Perfusion disorders are discussed as one of many possible causes of these alterations. Nowadays, chondral and osteochondral defects can be treated earlier due to detection using very sensitive magnetic resonance imaging (MRI) and computed tomography (CT) techniques. The use of conservative treatment only has a chance of healing in pediatric patients. Conservative measures for adults should only be considered as adjuvant treatment to surgery.Based on a comprehensive analysis of the current literature, this article gives an overview and critical analysis of the current concepts for treatment of chondral and osteochondral injuries and lesions of the talus. With arthroscopic therapy curettage and microfracture of talar lesions are the predominant approaches or retrograde drilling of the defect is another option when the chondral coating is retained. Implantation of autologous chondral cells or homologous juvenile cartilage tissue is also possible with arthroscopic techniques. Osteochondral fractures (flake fracture) are usually performed as a mini-open procedure supported by
Directory of Open Access Journals (Sweden)
P Orth
2013-06-01
Full Text Available Alterations of the subchondral bone are pathological features associated with spontaneous osteochondral repair following an acute injury and with articular cartilage repair procedures. The aim of this review is to discuss their incidence, extent and relevance, focusing on recent knowledge gained from both translational models and clinical studies of articular cartilage repair. Efforts to unravel the complexity of subchondral bone alterations have identified (1 the upward migration of the subchondral bone plate, (2 the formation of intralesional osteophytes, (3 the appearance of subchondral bone cysts, and (4 the impairment of the osseous microarchitecture as potential problems. Their incidence and extent varies among the different small and large animal models of cartilage repair, operative principles, and over time. When placed in the context of recent clinical investigations, these deteriorations of the subchondral bone likely are an additional, previously underestimated, factor that influences the long-term outcome of cartilage repair strategies. Understanding the role of the subchondral bone in both experimental and clinical articular cartilage repair thus holds great promise of being translated into further improved cell- or biomaterial-based techniques to preserve and restore the entire osteochondral unit.
Energy Technology Data Exchange (ETDEWEB)
Bohndorf, K. [Department of Radiology, Zentralklinikum Augsburg (Germany)
1999-10-01
Fractures involving the articulating surfaces of bone are a common cause of chronic disability after joint injury. Acute fractures of the articular surface typically run parallel to the surface and are confined to the cartilage and/or the immediate subchondral cancellous bone. They should be distinguished from vertical or oblique bone fractures with intra-articular extension. This article reviews the mechanism of acute articular surface injuries, as well as their incidence, clinical presentation, radiologic appearance and treatment. A classification is presented based on direct inspection (arthroscopy) and imaging (especially MRI), emphasizing the distinction between lesions with intact (subchondral impaction and subchondral bone bruises) and disrupted (chondral, osteochondral lesions) cartilage. Hyaline cartilage, subchondral bone plate and subchondral cancellous bone are to be considered an anatomic unit. Subchondral articular surface lesions, osteochondral fractures and solely chondral fractures are different manifestations of impaction injuries that affect the articulating surface. Of the noninvasive imaging modalities, conventional radiography and MRI provide the most relevant information. The appropriate use of short tau inversion recovery, T1-weighted and T2-weighted (turbo) spin-echo as well as gradient-echo sequences, enables MRI to classify the various acute articular surface lesions with great accuracy and provides therapeutic guidance. (orig.)
International Nuclear Information System (INIS)
Bohndorf, K.
1999-01-01
Fractures involving the articulating surfaces of bone are a common cause of chronic disability after joint injury. Acute fractures of the articular surface typically run parallel to the surface and are confined to the cartilage and/or the immediate subchondral cancellous bone. They should be distinguished from vertical or oblique bone fractures with intra-articular extension. This article reviews the mechanism of acute articular surface injuries, as well as their incidence, clinical presentation, radiologic appearance and treatment. A classification is presented based on direct inspection (arthroscopy) and imaging (especially MRI), emphasizing the distinction between lesions with intact (subchondral impaction and subchondral bone bruises) and disrupted (chondral, osteochondral lesions) cartilage. Hyaline cartilage, subchondral bone plate and subchondral cancellous bone are to be considered an anatomic unit. Subchondral articular surface lesions, osteochondral fractures and solely chondral fractures are different manifestations of impaction injuries that affect the articulating surface. Of the noninvasive imaging modalities, conventional radiography and MRI provide the most relevant information. The appropriate use of short tau inversion recovery, T1-weighted and T2-weighted (turbo) spin-echo as well as gradient-echo sequences, enables MRI to classify the various acute articular surface lesions with great accuracy and provides therapeutic guidance. (orig.)
Directory of Open Access Journals (Sweden)
Uğur Gönç
2016-10-01
Conclusion: In osteochondral massive allograft transplantations, the immune reaction of the host could be precluded with radiotherapy, and the side-effects can be prevented by low-dose fractionated regimen. The total dose of fractionated radiotherapy for an immune suppression should be adjusted not to damage the cartilage tissue, but to avoid articular degeneration in the long term.
Lippi, Donatella; Matucci-Cerinic, Marco; Villari, Natale; Fornaciari, Gino; Mascalchi, Mario
2010-03-01
We report a case of osteochondritis dissecans in the patella of Francesco de' Medici, Prince of Capistrano, who lived from 1594 to 1614. He was known to play Florentine kick ball, a precursor of Rugby and American football, and speculate that trauma from this activity may have led to the lesion. Copyright 2009 Elsevier B.V. All rights reserved.
International Nuclear Information System (INIS)
Marti-Bonmati, L.; Arana, E.; Tobarra, E.; Sierra, C.
2006-01-01
Purpose: To analyze the influence of different biphasic and monophasic injection rate protocols in abdominal computed tomography (CT). Material and Methods: A randomized, consecutive, parallel group study was designed and conducted in 60 patients studied with the same CT helical protocol. Patients were randomly distributed into three groups: (A) monophasic (120 ml at 2.5 ml/s); (B) low-high biphasic (120 ml, first 60 ml at a rate of 2 ml/s, the other 60 ml at 2.5 ml/s); and (C) high-low biphasic (120 ml, first 60 ml at a rate of 2.5 ml/s, the other 60 ml at 2 ml/s). All patients were injected with 300 mg I/ml non-ionic contrast media at a fixed delay time of 55 s. Contrast enhancement efficacy was evaluated by attenuation coefficient measurements. Results: Although non-significant, monophasic protocol enhancements were higher than biphasic protocol enhancements in all measurements except aortic bifurcation (p = 0.003). At this level, biphasic protocols obtained an increased mean enhancement from 7.6% to 2.5% compared to monophasic protocols. Conclusion: Monophasic contrast agent injection in helical CT of the upper abdomen produces a higher enhancement of parenchymal and venous structures. No significant difference was observed between low-high and high-low biphasic protocols
Autologous osteochondral mosaicplasty or TruFit plugs for cartilage repair.
Hindle, Paul; Hendry, Jane L; Keating, John F; Biant, Leela C
2014-06-01
Autologous osteochondral mosaicplasty and TruFit Bone graft substitute plugs are methods used to repair symptomatic articular cartilage defects in the adult knee. There have been no comparative studies of the two techniques. This retrospective study assessed functional outcome of patients using the EQ-5D, Knee Injury and Osteoarthritis Outcome Score (KOOS) and Modified Cincinnati scores at follow-up of 1-5 years. There were 66 patients in the study (35 TruFit and 31 Mosaicplasty): 44 males and 22 females with a mean age of 37.3 years (SD 12.6). The mean BMI was 26.8. Thirty-six articular cartilage lesions were due to trauma, twenty-six due to osteochondritis dissecans and three due to non-specific degenerative change or unknown. There was no difference between the two groups age (n.s.), sex (n.s.), BMI (n.s.), defect location (n.s.) or aetiology (n.s.). The median follow-up was 22 months for the TruFit cohort and 30 months for the mosaicplasty group. There was no significant difference in the requirement for re-operation (n.s). Patients undergoing autologous mosaicplasty had a higher rate of returning to sport (p = 0.006), lower EQ-5D pain scores (p = 0.048) and higher KOOS activities of daily living (p = 0.029) scores. Sub-group analysis showed no difference related to the number of cases the surgeon performed. Patients requiring re-operation had lower outcome scores regardless of their initial procedure. This study demonstrated significantly better outcomes using two validated outcome scores (KOOS, EQ-5D), and an ability to return to sport in those undergoing autologous mosaicplasty compared to those receiving TruFit plugs. IV.
Yang, Hanbae; McCoy, Edward L; Grewal, Parwinder S; Dick, Warren A
2010-08-01
Rain gardens are bioretention systems that have the potential to reduce peak runoff flow and improve water quality in a natural and aesthetically pleasing manner. We compared hydraulic performance and removal efficiencies of nutrients and atrazine in a monophasic rain garden design versus a biphasic design at a column-scale using simulated runoff. The biphasic rain garden was designed to increase retention time and removal efficiency of runoff pollutants by creating a sequence of water saturated to unsaturated conditions. We also evaluated the effect of C substrate availability on pollutant removal efficiency in the biphasic rain garden. Five simulated runoff events with various concentrations of runoff pollutants (i.e. nitrate, phosphate, and atrazine) were applied to the monophasic and biphasic rain gardens once every 5d. Hydraulic performance was consistent over the five simulated runoff events. Peak flow was reduced by approximately 56% for the monophasic design and 80% for the biphasic design. Both rain garden systems showed excellent removal efficiency of phosphate (89-100%) and atrazine (84-100%). However, significantly (prain garden (29-39%). Addition of C substrate in the form of glucose increased removal efficiency of nitrate significantly (prain gardens. (c) 2010 Elsevier Ltd. All rights reserved.
van Bergen, C.J.A.; Blankevoort, L.; de Haan, R.J.; Sierevelt, I.N.; Meuffels, D.E.; d'Hooghe, P.R.N.; Krips, R.; van Damme, G.; van Dijk, C.N.
2009-01-01
ABSTRACT: BACKGROUND: Osteochondral talar defects usually affect athletic patients. The primary surgical treatment consists of arthroscopic debridement and microfracturing. Although this is mostly successful, early sport resumption is difficult to achieve, and it can take up to one year to obtain
C.J.A. van Bergen (Christiaan); L. Blankevoort (Leendert); R.J. de Haan (Rob); I.N. Sierevelt (Inger); D.E. Meuffels (Duncan); P.R.N. D'Hooghe (Pieter); R. Krips (Rover); G. van Damme (Geert); C.N. van Dijk (Niek)
2009-01-01
textabstractBackground. Osteochondral talar defects usually affect athletic patients. The primary surgical treatment consists of arthroscopic debridement and microfracturing. Although this is mostly successful, early sport resumption is difficult to achieve, and it can take up to one year to obtain
Son, Jun-Sik; Kim, Su-Gwan; Oh, Ji-Su; Appleford, Mark; Oh, Sunho; Ong, Joo L; Lee, Kyu-Bok
2011-12-15
This study presents a novel design of a ceramic/polymer biphasic combination scaffold that mimics natural bone structures and is used as a bone graft substitute. To mimic the natural bone structures, the outside cortical-like shells were composed of porous hydroxyapatite (HA) with a hollow interior using a polymeric template-coating technique; the inner trabecular-like core consisted of porous poly(D,L-lactic acid) (PLA) that was loaded with dexamethasone (DEX) and was directly produced using a particle leaching/gas forming technique to create the inner diameter of the HA scaffold. It was observed that the HA and PLA parts of the fabricated HA/PLA biphasic scaffold contained open and interconnected pore structures, and the boundary between both parts was tightly connected without any gaps. It was found that the structure of the combination scaffold was analogous to that of natural bone based on micro-computed tomography analysis. Additionally, the dense, uniform apatite layer was formed on the surface of the HA/PLA biphasic scaffold through a biomimetic process, and DEX was successfully released from the PLA of the biphasic scaffold over a 1-month period. This release caused human embryonic palatal mesenchyme cells to proliferate, differentiate, produce ECM, and form tissue in vitro. Therefore, it was concluded that this functionally graded scaffold is similar to natural bone and represents a potential bone-substitute material. Copyright © 2011 Wiley Periodicals, Inc.
Biphasic Malignant Pleural Mesothelioma Masquerading as a Primary Skeletal Tumor
Directory of Open Access Journals (Sweden)
James Benjamin Gleason
2016-01-01
Full Text Available Biphasic malignant pleural mesothelioma is a rare malignant tumor, usually presenting as a pleural-based mass in a patient with history of chronic asbestos exposure. We herein report a case of a 41-year-old man who presented with chest pain and had a chest computed tomography (CT scan suggestive of a primary skeletal tumor originating from the ribs (chondrosarcoma or osteosarcoma, with no history of asbestos exposure. CT-guided core needle biopsies were diagnosed as malignant sarcomatoid mesothelioma. Surgical resection and chest wall reconstruction were performed, confirming the diagnosis and revealing a secondary histologic component (epithelioid, supporting the diagnosis of biphasic malignant mesothelioma.
Meniscal root entrapment of an osteochondritis dissecans loose body.
Jones, Christopher R; McMonagle, Joseph S; Garrett, William E
2014-09-01
Loose bodies are relatively common in the knee. On radiographs they can often be seen in the medial and lateral gutters, intercondylar notch, and the posterior compartment. At times an apparent loose body is not free to move in the knee because it has been covered by synovium and is no longer mobile. It is uncommon for an osteochondral loose body to become incorporated into meniscal tissue. We report a case of an apparent loose body becoming incorporated into the posterior horn and root of the medial meniscus. We are not aware that this condition has been previously reported. Because removing the entire loose body would have destabilized the posterior root of the medial meniscus, it is important to be aware of this potential occurrence.
Directory of Open Access Journals (Sweden)
José Leão Ribeiro
2004-03-01
Full Text Available Este estudo teve como finalidade avaliar macroscopicamente e histológicamente defeitos osteocondrais já cicatrizados, também conhecidos como reparos. Foram utilizados seis coelhos machos, adultos, albinos da raça Nova Zelândia. Defeitos cilíndricos osteocondrais de 3.2 mm de diâmetro por 4.0 mm de profundidade foram criados cirurgicamente em ambos côndilos femorais mediais. O cilindro osteocondral retirado do joelho esquerdo (defeito não tratado foi implantado no joelho direito (joelho tratado. Comparou-se macroscopicamente e histológicamente ambos tipos de defeitos após doze semanas de evolução. A avaliação macroscópica de todos os defeitos mostrou evolução para reparos denominados biologicamente aceitáveis. O termo "biologicamente aceitável" foi utilizado para definir reparos, que à observação macroscópica, se apresentaram como tecido neo-formado semelhante à fibrocartilagem, brilhante, liso, firme, em continuidade com a cartilagem adjacente. Como todos os defeitos, tratados e não tratados, eram macroscopicamente semelhantes, realizou-se um estudo histológico comparativo para averiguar qual tipo de tecido de reparação se formava em ambos defeitos. Pela análise histológica dos reparos biologicamente aceitáveis, concluiu-se que houve formação de tecido cartilaginoso hialino nos defeitos tratados com enxerto autólogo e de tecido fibrocartilaginoso nos defeitos não tratados.The aim of this study was to evaluate macroscopically and histologically healed osteochondral defects, also known as repairs. Six adult, male, New Zealander White rabbits were used. Cylindrical osteochondral defects of 3.2 mm in diameter by 4.0 mm in depth were artificially created in the load-bearing surfaces of both medial femoral condyles. The osteochondral graft collected from the left knee (untreated defect was implanted in the right knee (treated defect. Both defects were compared macroscopically ad histologically after twelve weeks
Energy Technology Data Exchange (ETDEWEB)
Hays, Lance G. [Douglas Energy Company, Placentia, CA (United States)
2000-09-01
A full scale, wellhead Biphase turbine was manufactured and installed with the balance of plant at Well 103 of the Cerro Prieto geothermal resource in Baja, California. The Biphase turbine was first synchronized with the electrical grid of Comision Federal de Electricidad on August 20, 1997. The Biphase power plant was operated from that time until May 23, 2000, a period of 2 years and 9 months. A total of 77,549 kWh were delivered to the grid. The power plant was subsequently placed in a standby condition pending replacement of the rotor with a newly designed, higher power rotor and replacement of the bearings and seals. The maximum measured power output of the Biphase turbine, 808 kWe at 640 psig wellhead pressure, agreed closely with the predicted output, 840 kWe. When combined with the backpressure steam turbine the total output power from that flow would be increased by 40% above the power derived only from the flow by the present flash steam plant. The design relations used to predict performance and design the turbine were verified by these tests. The performance and durability of the Biphase turbine support the conclusion of the Economics and Application Report previously published, (Appendix A). The newly designed rotor (the Dual Pressure Rotor) was analyzed for the above power condition. The Dual Pressure Rotor would increase the power output to 2064 kWe by incorporating two pressure letdown stages in the Biphase rotor, eliminating the requirement for a backpressure steam turbine. The power plant availability was low due to deposition of solids from the well on the Biphase rotor and balance of plant problems. A great deal of plant down time resulted from the requirement to develop methods to handle the solids and from testing the apparatus in the Biphase turbine. Finally an online, washing method using the high pressure two-phase flow was developed which completely eliminated the solids problem. The availability of the Biphase turbine itself was 100
Directory of Open Access Journals (Sweden)
Michiel W. Pot
2016-09-01
Full Text Available Microfracture surgery may be applied to treat cartilage defects. During the procedure the subchondral bone is penetrated, allowing bone marrow-derived mesenchymal stem cells to migrate towards the defect site and form new cartilage tissue. Microfracture surgery generally results in the formation of mechanically inferior fibrocartilage. As a result, this technique offers only temporary clinical improvement. Tissue engineering and regenerative medicine may improve the outcome of microfracture surgery. Filling the subchondral defect with a biomaterial may provide a template for the formation of new hyaline cartilage tissue. In this study, a systematic review and meta-analysis were performed to assess the current evidence for the efficacy of cartilage regeneration in preclinical models using acellular biomaterials implanted after marrow stimulating techniques (microfracturing and subchondral drilling compared to the natural healing response of defects. The review aims to provide new insights into the most effective biomaterials, to provide an overview of currently existing knowledge, and to identify potential lacunae in current studies to direct future research. A comprehensive search was systematically performed in PubMed and EMBASE (via OvidSP using search terms related to tissue engineering, cartilage and animals. Primary studies in which acellular biomaterials were implanted in osteochondral defects in the knee or ankle joint in healthy animals were included and study characteristics tabulated (283 studies out of 6,688 studies found. For studies comparing non-treated empty defects to defects containing implanted biomaterials and using semi-quantitative histology as outcome measure, the risk of bias (135 studies was assessed and outcome data were collected for meta-analysis (151 studies. Random-effects meta-analyses were performed, using cartilage regeneration as outcome measure on an absolute 0–100% scale. Implantation of acellular
Pot, Michiel W; Gonzales, Veronica K; Buma, Pieter; IntHout, Joanna; van Kuppevelt, Toin H; de Vries, Rob B M; Daamen, Willeke F
2016-01-01
Microfracture surgery may be applied to treat cartilage defects. During the procedure the subchondral bone is penetrated, allowing bone marrow-derived mesenchymal stem cells to migrate towards the defect site and form new cartilage tissue. Microfracture surgery generally results in the formation of mechanically inferior fibrocartilage. As a result, this technique offers only temporary clinical improvement. Tissue engineering and regenerative medicine may improve the outcome of microfracture surgery. Filling the subchondral defect with a biomaterial may provide a template for the formation of new hyaline cartilage tissue. In this study, a systematic review and meta-analysis were performed to assess the current evidence for the efficacy of cartilage regeneration in preclinical models using acellular biomaterials implanted after marrow stimulating techniques (microfracturing and subchondral drilling) compared to the natural healing response of defects. The review aims to provide new insights into the most effective biomaterials, to provide an overview of currently existing knowledge, and to identify potential lacunae in current studies to direct future research. A comprehensive search was systematically performed in PubMed and EMBASE (via OvidSP) using search terms related to tissue engineering, cartilage and animals. Primary studies in which acellular biomaterials were implanted in osteochondral defects in the knee or ankle joint in healthy animals were included and study characteristics tabulated (283 studies out of 6,688 studies found). For studies comparing non-treated empty defects to defects containing implanted biomaterials and using semi-quantitative histology as outcome measure, the risk of bias (135 studies) was assessed and outcome data were collected for meta-analysis (151 studies). Random-effects meta-analyses were performed, using cartilage regeneration as outcome measure on an absolute 0-100% scale. Implantation of acellular biomaterials significantly
Directory of Open Access Journals (Sweden)
Ana M. Cortizo
2016-01-01
Full Text Available Bone and cartilage regeneration can be improved by designing a functionalized biomaterial that includes bioactive drugs in a biocompatible and biodegradable scaffold. Based on our previous studies, we designed a vanadium-loaded collagen scaffold for osteochondral tissue engineering. Collagen-vanadium loaded scaffolds were characterized by SEM, FTIR, and permeability studies. Rat bone marrow progenitor cells were plated on collagen or vanadium-loaded membranes to evaluate differences in cell attachment, growth and osteogenic or chondrocytic differentiation. The potential cytotoxicity of the scaffolds was assessed by the MTT assay and by evaluation of morphological changes in cultured RAW 264.7 macrophages. Our results show that loading of VOAsc did not alter the grooved ordered structure of the collagen membrane although it increased membrane permeability, suggesting a more open structure. The VOAsc was released to the media, suggesting diffusion-controlled drug release. Vanadium-loaded membranes proved to be a better substratum than C0 for all evaluated aspects of BMPC biocompatibility (adhesion, growth, and osteoblastic and chondrocytic differentiation. In addition, there was no detectable effect of collagen or vanadium-loaded scaffolds on macrophage viability or cytotoxicity. Based on these findings, we have developed a new ordered collagen scaffold loaded with VOAsc that shows potential for osteochondral tissue engineering.
A new solution in cartilage repair surgery of joint lesions
Directory of Open Access Journals (Sweden)
Patrascu JM¹,
2016-12-01
Full Text Available OBJECTIVES AND BACKGROUND The purpose of this study is to provide a simple, cost-effective, reproducible technology that is able to regenerate durable hyaline cartilage. Traumas and sports along with different diseases such as obesity or gradual degeneration over time of the joint surface determine cartilage defects resulting in pain and dysfunctionality. MATERIALS AND METHODS Since 2011 a number of 183 pacients were treated using Agili-C, out of which 40 pacients were operated in the IInd Clinic of Orthopaedics of the Timișoara Emergency County Hospital. The implant is a biphasic, porous, resorbable tissue regeneration scaffold used in the treatment of osteochondral defects. The surgical procedure is performed through minimal arthrotomy, with a good exposure of the cartilage defect. The implant is inserted so that the articular surface of the implant is parallel with the surrounding healthy cartilage. When in place, it facilitates vascularization thus allowing tissue formation to commence from the periphery towards the center of the defect. RESULTS Until now, results are promising, showing obvious improvements in pain and function in both degenerative and post-traumatic joint lesions in the knee, ankle and first MP joint. CONCLUSIONS Agili-C is a cell free, single stage, off the shelf implant that will hopefully meet market demands and become a reliable procedure in joint repair surgery in the future. Figure 1: Intra-operative aspect after the implant is in place. REFERENCES 1. Mehdi Kazemzadeh-Narbat et al. Biomaterials.2010. p.31. 2. Scaglione et al. Tissue engineering: Part A. 2009;15:1. FOOTNOTE Agili-C is a product of CartiHeal Company
Biphasic Clinical Course Among Kenyan Children With Cerebral ...
African Journals Online (AJOL)
Background Cerebral malaria is the most severe neurological complication of Falciparum malaria. It is associated with a significant risk of death and neurological sequelae. A biphasic clinical picture is associated with an even greater risk of neurological sequelae. Objective To examine the incidence and clinical ...
Actinide recovery using aqueous biphasic extraction: Initial developmental studies
International Nuclear Information System (INIS)
Chaiko, D.J.; Mensah-Biney, R.; Mertz, C.J.; Rollins, A.N.
1992-08-01
Aqueous biphasic extraction systems are being developed to treat radioactive wastes. The separation technique involves the selective partitioning of either solutes or colloid-size particles between two scible aqueous phases. Wet grinding of plutonium residues to an average particle size of one micron will be used to liberate the plutonium from the bulk of the particle matrix. The goal is to produce a plutonium concentrate that will integrate with existing and developing chemical recovery processes. Ideally, the process would produce a nonTRU waste stream. Coupling physical beneficiation with chemical processing will result in a substantial reduction in the volume of mixed wastes generated from dissolution recovery processes. As part of this program, we will also explore applications of aqueous biphasic extraction that include the separation and recovery of dissolved species such as metal ions and water-soluble organics. The expertise and data generated in this work will form the basis for developing more cost-effective processes for handling waste streams from environmental restoration and waste management activities within the DOE community. This report summarizes the experimental results obtained during the first year of this effort. Experimental efforts were focused on elucidating the surface and solution chemistry variables which govern partitioning behavior of plutonium and silica in aqueous biphasic extraction systems. Additional efforts were directed toward the development of wet grinding methods for producing ultrafine particles with diameters of one micron or less
Actinide recovery using aqueous biphasic extraction: Initial developmental studies
Energy Technology Data Exchange (ETDEWEB)
Chaiko, D.J.; Mensah-Biney, R.; Mertz, C.J.; Rollins, A.N.
1992-08-01
Aqueous biphasic extraction systems are being developed to treat radioactive wastes. The separation technique involves the selective partitioning of either solutes or colloid-size particles between two scible aqueous phases. Wet grinding of plutonium residues to an average particle size of one micron will be used to liberate the plutonium from the bulk of the particle matrix. The goal is to produce a plutonium concentrate that will integrate with existing and developing chemical recovery processes. Ideally, the process would produce a nonTRU waste stream. Coupling physical beneficiation with chemical processing will result in a substantial reduction in the volume of mixed wastes generated from dissolution recovery processes. As part of this program, we will also explore applications of aqueous biphasic extraction that include the separation and recovery of dissolved species such as metal ions and water-soluble organics. The expertise and data generated in this work will form the basis for developing more cost-effective processes for handling waste streams from environmental restoration and waste management activities within the DOE community. This report summarizes the experimental results obtained during the first year of this effort. Experimental efforts were focused on elucidating the surface and solution chemistry variables which govern partitioning behavior of plutonium and silica in aqueous biphasic extraction systems. Additional efforts were directed toward the development of wet grinding methods for producing ultrafine particles with diameters of one micron or less.
Lu, S.; Lam, J.; Trachtenberg, J.E.; Lee, E.J.; Seyednejad, H.; Beucken, J.J.J.P van den; Tabata, Y.; Kasper, F.K.; Scott, D.W.; Wong, M.E.; Jansen, J.A.; Mikos, A.G.
2015-01-01
The present work investigated correlations between cartilage and subchondral bone repair, facilitated by a growth factor-delivering scaffold, in a rabbit osteochondral defect model. Histological scoring indices and microcomputed tomography morphological parameters were used to evaluate cartilage and
Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation
Directory of Open Access Journals (Sweden)
S.A. Arias
2013-12-01
Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.
Deep eutectic solvents as performance additives in biphasic reactions
Lan, Dongming; Wang, Xuping; Zhou, Pengfei; Hollmann, F.; Wang, Yonghua
2017-01-01
Deep eutectic solvents act as surfactants in biphasic (hydrophobic/aqueous) reaction mixtures enabling higher interfacial surface areas at lower mechanical stress as compared to simple emulsions. Exploiting this effect the rate of a chemoenzymatic epoxidation reaction was increased more than
Lam, J.; Lu, S.; Lee, E.J.; Trachtenberg, J.E.; Meretoja, V.V.; Dahlin, R.L.; van den Beucken, J.J.; Tabata, Y.; Wong, M.E.; Jansen, J.A.; Mikos, A.G.; Kasper, F.K.
2014-01-01
OBJECTIVE: To investigate the ability of cell-laden bilayered hydrogels encapsulating chondrogenically and osteogenically (OS) pre-differentiated mesenchymal stem cells (MSCs) to effect osteochondral defect repair in a rabbit model. By varying the period of chondrogenic pre-differentiation from 7
Chen, Ying; Kawazoe, Naoki; Chen, Guoping
2018-02-01
Although bone is regenerative, its regeneration capacity is limited. For bone defects beyond a critical size, further intervention is required. As an attractive strategy, bone tissue engineering (bone TE) has been widely investigated to repair bone defects. However, the rapid and effective bone regeneration of large non-healing defects is still a great challenge. Multifunctional scaffolds having osteoinductivity and osteoconductivity are desirable to fasten functional bone tissue regeneration. In the present study, biomimetic composite scaffolds of collagen and biphasic calcium phosphate nanoparticles (BCP NPs) with a controlled release of dexamethasone (DEX) and the controlled pore structures were prepared for bone TE. DEX was introduced in the BCP NPs during preparation of the BCP NPs and hybridized with collagen scaffolds, which pore structures were controlled by using pre-prepared ice particulates as a porogen material. The composite scaffolds had well controlled and interconnected pore structures, high mechanical strength and a sustained release of DEX. The composite scaffolds showed good biocompatibility and promoted osteogenic differentiation of hMSCs when used for three-dimensional culture of human bone marrow-derived mesenchymal stem cells. Subcutaneous implantation of the composite scaffolds at the dorsa of athymic nude mice demonstrated that they facilitated the ectopic bone tissue regeneration. The results indicated the DEX-loaded BCP NPs/collagen composite scaffolds had high potential for bone TE. Scaffolds play a crucial role for regeneration of large bone defects. Biomimetic scaffolds having the same composition of natural bone and a controlled release of osteoinductive factors are desirable for promotion of bone regeneration. In this study, composite scaffolds of collagen and biphasic CaP nanoparticles (BCP NPs) with a controlled release nature of dexamethasone (DEX) were prepared and their porous structures were controlled by using ice particulates
Schmidt, S; Schulte, A; Schwarz, S; Hofmann, N; Tietz, S; Boergel, M; Sixt, S U
2017-11-01
The biggest obstacle to overcome for routine treatment of various pathologies with fresh osteochondral allograft is the availability of tissue for transplantation. Large fresh osteochondral allografts are usually harvested from organ donors, but in contrast to organs, tissues can be procured after cardiac arrest. Medical staff as well the general public are much less aware of the possibilities and requirements of tissue donation compared to organ donation. This review aims to highlight the current situation of organ and tissue donation in Europe and to raise this much needed awareness. For this research, PubMed database was scanned using the terms "tissue/organ donation", "bone donation/transplantation", "cartilage transplantation/allografts" and "osteochrondral allografts". Relatives of potential donors are often not approached because physicians and nurses do not feel sufficiently prepared for this task and, thus, are reluctant to address this topic. Different options could alleviate the pressure medical staff is feeling. Furthermore, there are different factors influencing consent that can be addressed to increase donation rates. Currently, a lot of potential concerning musculoskeletal tissue grafts remains unused. Most importantly, families should be encouraged to speak about their potenzial will to donate and educational programs should be established to increase trust in organ and tissue donation and the allocation system and to increase knowledge about the importance of transplantation medicine. But joined efforts of different parts of the medical systems and different organizations involved in tissue transplantation should improve the situation for patients waiting for much needed transplants.
de Wild, Michael; Amacher, Fabienne; Bradbury, Christopher R; Molenberg, Aart
2016-04-01
Resorbable bone substitute materials are widely used for bone augmentation after tumor resection, parallel to implant placement, or in critical size bone defects. In this study, the structural dissolution of a biphasic calcium phosphate bone substitute material with a hydroxyapatite (HA)/tricalcium phosphate (β-TCP) ratio of 60/40 was investigated by repeatedly placing porous blocks in EDTA solution at 37 °C. At several time points, the blocks were investigated by SEM, µCT, and gravimetry. It was found that always complete 2-3 µm sized grains were removed from the structure and that the β-TCP is dissolved more rapidly. This selective dissolution of the β-TCP grains was confirmed by XRD measurements. The blocks were eroded from the outside toward the center. The structure remained mechanically stable because the central part showed a delayed degradation and because the slower dissolving HA grains preserved the integrity of the structure. © 2015 Wiley Periodicals, Inc.
Pathak, Amit
2018-04-12
Motile cells sense the stiffness of their extracellular matrix (ECM) through adhesions and respond by modulating the generated forces, which in turn lead to varying mechanosensitive migration phenotypes. Through modeling and experiments, cell migration speed is known to vary with matrix stiffness in a biphasic manner, with optimal motility at an intermediate stiffness. Here, we present a two-dimensional cell model defined by nodes and elements, integrated with subcellular modeling components corresponding to mechanotransductive adhesion formation, force generation, protrusions and node displacement. On 2D matrices, our calculations reproduce the classic biphasic dependence of migration speed on matrix stiffness and predict that cell types with higher force-generating ability do not slow down on very stiff matrices, thus disabling the biphasic response. We also predict that cell types defined by lower number of total receptors require stiffer matrices for optimal motility, which also limits the biphasic response. For a cell type with robust biphasic migration on 2D surface, simulations in channel-like confined environments of varying width and height predict faster migration in more confined matrices. Simulations performed in shallower channels predict that the biphasic mechanosensitive cell migration response is more robust on 2D micro-patterns as compared to the channel-like 3D confinement. Thus, variations in the dimensionality of matrix confinement alters the way migratory cells sense and respond to the matrix stiffness. Our calculations reveal new phenotypes of stiffness- and topography-sensitive cell migration that critically depend on both cell-intrinsic and matrix properties. These predictions may inform our understanding of various mechanosensitive modes of cell motility that could enable tumor invasion through topographically heterogeneous microenvironments. © 2018 IOP Publishing Ltd.
Zhang, Xiudong; Bai, Yuanyuan; Cao, Xuefei; Sun, Runcang
2017-08-01
Herein, an efficient biphasic pretreatment process was developed to improve the production of furfural (FF) and glucose from Eucalyptus. The influence of formic acid and NaCl on FF production from xylose in water and various biphasic systems was investigated. Results showed that the addition of formic acid and NaCl significantly promoted the FF yield, and the biphasic system of MIBK (methyl isobutyl ketone)/water exhibited the best performance for FF production. Then the Eucalyptus was pretreated in the MIBK/water system, and a maximum FF yield of 82.0% was achieved at 180°C for 60min. Surface of the pretreated Eucalyptus became relatively rough and loose, and its crystallinity index increased obviously due to the removal of hemicelluloses and lignin. The pretreated Eucalyptus samples showed much higher enzymatic hydrolysis rates (26.2-70.7%) than the raw Eucalyptus (14.5%). Copyright © 2017 Elsevier Ltd. All rights reserved.
DEFF Research Database (Denmark)
Mrachacz-Kersting, Natalie; Stevenson, Andrew James Thomas
2017-01-01
Paired associative stimulation (PAS) protocols induce plastic changes within the motor cortex. The objectives of this study were to investigate PAS effects targeting the tibialis anterior (TA) muscle using a biphasic transcranial magnetic stimulation (TMS) pulse form and, to determine whether...... a reduced intensity of this pulse would lead to significant changes as has been reported for hand muscles using a monophasic TMS pulse. Three interventions were investigated: (1) suprathreshold PAbi-PAS (n = 11); (2) suprathreshold PAmono-PAS (n = 11) where PAS was applied using a biphasic or monophasic......% for subthreshold PAbi-PAS. PAS using a biphasic pulse form at subthreshold intensities induces similar effects to conventional PAS....
Harada, Yohei; Nakasa, Tomoyuki; Mahmoud, Elhussein Elbadry; Kamei, Goki; Adachi, Nobuo; Deie, Masataka; Ochi, Mitsuo
2015-10-01
The present study investigated intra-articular injection of bone-marrow-derived mesenchymal stem cells (MSCs) combined with articulated joint distraction as treatment for osteochondral defects. Large osteochondral defects were created in the weight-bearing area of the medial femoral condyle in rabbit knees. Four weeks after defect creation, rabbits were divided into six groups: control group, MSC group, distraction group, distraction + MSC group, temporary distraction group, and temporary distraction + MSC group. Groups with MSC received intra-articular injection of MSCs. Groups with distraction underwent articulated distraction arthroplasty. Groups with temporary distraction discontinued the distraction after 4 weeks. The rabbits were euthanized at 4, 8, and 12 weeks after treatment except temporary distraction groups which were euthanized at only 12 weeks. Histological scores in the distraction + MSC group were significantly better than in the control, MSC group or distraction group at 4 and 8 weeks, but showed no further improvement. At 12 weeks, the temporary distraction + MSC group showed the best results, demonstrating hyaline cartilage repair with regeneration of the osteochondral junction. In conclusion, joint distraction with intra-articular injection of MSCs promotes early cartilage repair, and compressive loading of the repair tissue after temporary distraction stimulates articular cartilage regeneration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Osteochondritis dissecans of the knee joint: A diagnosis not to miss
Directory of Open Access Journals (Sweden)
Rahul R Bagul
2014-01-01
Full Text Available Osteochondritis dissecans (OCD is the most common cause of a loose body in the joint space in adolescent patients. Diagnosis requires a high index of suspicion as clinical findings are often subtle. Limited range of motion may be the only notable clinical sign. The diagnosis is made by thorough clinical examination, radiographic examination and magnetic resonance imaging (MRI. Early diagnosis and treatment can change the prognosis of the disease. If not diagnosed early, OCD can lead to the development of osteoarthritis at an early age. Conservative management is the mainstay of treatment for stable lesions. While the majority of patients respond to conservative treatment, those with unstable lesions require arthroscopic management.
Cell–material interactions on biphasic polyurethane matrix
Dicesare, Patrick; Fox, Wade M.; Hill, Michael J.; Krishnan, G. Rajesh; Yang, Shuying; Sarkar, Debanjan
2013-01-01
Cell–matrix interaction is a key regulator for controlling stem cell fate in regenerative tissue engineering. These interactions are induced and controlled by the nanoscale features of extracellular matrix and are mimicked on synthetic matrices to control cell structure and functions. Recent studies have shown that nanostructured matrices can modulate stem cell behavior and exert specific role in tissue regeneration. In this study, we have demonstrated that nanostructured phase morphology of synthetic matrix can control adhesion, proliferation, organization and migration of human mesenchymal stem cells (MSCs). Nanostructured biodegradable polyurethanes (PU) with segmental composition exhibit biphasic morphology at nanoscale dimensions and can control cellular features of MSCs. Biodegradable PU with polyester soft segment and hard segment composed of aliphatic diisocyanates and dipeptide chain extender were designed to examine the effect polyurethane phase morphology. By altering the polyurethane composition, morphological architecture of PU was modulated and its effect was examined on MSC. Results show that MSCs can sense the nanoscale morphology of biphasic polyurethane matrix to exhibit distinct cellular features and, thus, signifies the relevance of matrix phase morphology. The role of nanostructured phases of a synthetic matrix in controlling cell–matrix interaction provides important insights for regulation of cell behavior on synthetic matrix and, therefore, is an important tool for engineering tissue regeneration. PMID:23255285
Fabrication and tritium release property of Li2TiO3-Li4SiO4 biphasic ceramics
Yang, Mao; Ran, Guangming; Wang, Hailiang; Dang, Chen; Huang, Zhangyi; Chen, Xiaojun; Lu, Tiecheng; Xiao, Chengjian
2018-05-01
Li2TiO3-Li4SiO4 biphasic ceramic pebbles have been developed as an advanced tritium breeder due to the potential to combine the advantages of both Li2TiO3 and Li4SiO4. Wet method was developed for the pebble fabrication and Li2TiO3-Li4SiO4 biphasic ceramic pebbles were successfully prepared by wet method using the powders synthesized by hydrothermal method. The tritium release properties of the Li2TiO3-Li4SiO4 biphasic ceramic pebbles were evaluated. The biphasic pebbles exhibited good tritium release property at low temperatures and the tritium release temperature was around 470 °C. Because of the isotope exchange reaction between H2 and tritium, the addition of 0.1%H2 to purge gas He could significantly enhance the tritium gas release and the fraction of molecular form of tritium increased from 28% to 55%. The results indicate that the Li2TiO3-Li4SiO4 biphasic ceramic pebbles fabricated by wet method exhibit good tritium release property and hold promising potential as advanced breeder pebbles.
Biphase sinusoidal oscillator based on negative resistor.
Bayard, Jean
2010-06-01
This paper describes a biphase sinusoidal generator which provides two signals: v(ref)=V(M) sin(omegat) and v(out)=V(M) sin(omegat+DeltaPhi), where DeltaPhi is in the range 0, pi/2 or -pi/2, 0 and is not dependent on the frequency value. It is based on a negative resistor and it requires very few components. SPICE simulations and measurements on an experimental setup confirm the theoretical analysis.
Wouters, Diederick B.; Bos, Rudolf R. M.; van Horn, Jim R.; van Luyn, Marja J. A.
Most of the metallic devices have to be removed, treating osteochondritis dissecans lesions. This animal study describes the biological and mechanical behavior of screws and pins, made of commercially available PGA/PLA and PLA96 and metallic screws and pins, used for fragment fixation. A sham
A New Type of Biphasic Calcium Phosphate Cement as a Gentamicin Carrier for Osteomyelitis
Directory of Open Access Journals (Sweden)
Wen-Yu Su
2013-01-01
Full Text Available Osteomyelitis therapy is a long-term and inconvenient procedure for a patient. Antibiotic-loaded bone cements are both a complementary and alternative treatment option to intravenous antibiotic therapy for the treatment of osteomyelitis. In the current study, the biphasic calcium phosphate cement (CPC, called α-TCP/HAP (α-tricalcium phosphate/hydroxyapatite biphasic cement, was prepared as an antibiotics carrier for osteomyelitis. The developed biphasic cement with a microstructure of α-TCP surrounding the HAP has a fast setting time which will fulfill the clinical demand. The X-ray diffraction and Fourier transform infrared spectrometry analyses showed the final phase to be HAP, the basic bone mineral, after setting for a period of time. Scanning electron microscopy revealed a porous structure with particle sizes of a few micrometers. The addition of gentamicin in α-TCP/HAP would delay the transition of α-TCP but would not change the final-phase HAP. The gentamicin-loaded α-TCP/HAP supplies high doses of the antibiotic during the initial 24 hours when they are soaked in phosphate buffer solution (PBS. Thereafter, a slower drug release is produced, supplying minimum inhibitory concentration until the end of the experiment (30 days. Studies of growth inhibition of Staphylococcus aureus and Pseudomonas aeruginosa in culture indicated that gentamicin released after 30 days from α-TCP/HAP biphasic cement retained antibacterial activity.
Directory of Open Access Journals (Sweden)
Marco Corzani
2017-01-01
Full Text Available Osteocondrithisdissecans (OCD is an acquired disease due to a subcondral bone ischaemia that affects generally the medial femoral condyle as well as above lying cartilage. Though the incidence of OCD is only 6/10,000 in the general population, in the later stages of disease, OCD fragment can break off inside the articular cavity it is the most Frequently reported cause of free endoarticular body The etiology has been hypothesized as being multi-factored due to traumas or microtraumas along with metabolic, endocrine and genetic disorders leading to subchondral ischemia . Description of case A 15-year old male amateur soccer player presented to our department complaining of recurrent episodes of pain at rest in both knees, swelling and articular blockage occurring over the past 3 years. RX and MRIrevealed bilateral lesions on both medial condyles. A ONE-STEP surgical technique was performed that incorporated the drawing of mesenchymal staminal cells (MSCs and their implantation. Conclusion This case report deals with a rare case of bilateral OCD of the knee treated with the latest technique in regenerative medicine. At 6-month follow up there was a complete return of muscular tonality in both knees andthe patient was allowed to return to light physical activity. These results are noteworthyfor the fact they were obtained from a combined surgical approach that when compared toalternative approaches lead to a shorter hospital stay and a reduced hospital burden. Each of the osteochondral lesions was evaluated from imaging results and arthroscopic findings.
Rustom, Laurence E; Boudou, Thomas; Lou, Siyu; Pignot-Paintrand, Isabelle; Nemke, Brett W; Lu, Yan; Markel, Mark D; Picart, Catherine; Wagoner Johnson, Amy J
2016-10-15
The increasing demand for bone repair solutions calls for the development of efficacious bone scaffolds. Biphasic calcium phosphate (BCP) scaffolds with both macropores and micropores (MP) have improved healing compared to those with macropores and no micropores (NMP), but the role of micropores is unclear. Here, we evaluate capillarity induced by micropores as a mechanism that can affect bone growth in vivo. Three groups of cylindrical scaffolds were implanted in pig mandibles for three weeks: MP were implanted either dry (MP-Dry), or after submersion in phosphate buffered saline, which fills pores with fluid and therefore suppresses micropore-induced capillarity (MP-Wet); NMP were implanted dry. The amount and distribution of bone in the scaffolds were quantified using micro-computed tomography. MP-Dry had a more homogeneous bone distribution than MP-Wet, although the average bone volume fraction, BVF‾, was not significantly different for these two groups (0.45±0.03 and 0.37±0.03, respectively). There was no significant difference in the radial bone distribution of NMP and MP-Wet, but the BVF‾, of NMP was significantly lower among the three groups (0.25±0.02). These results suggest that micropore-induced capillarity enhances bone regeneration by improving the homogeneity of bone distribution in BCP scaffolds. The explicit design and use of capillarity in bone scaffolds may lead to more effective treatments of large and complex bone defects. The increasing demand for bone repair calls for more efficacious bone scaffolds and calcium phosphate-based materials are considered suitable for this application. Macropores (>100μm) are necessary for bone ingrowth and vascularization. However, studies have shown that microporosity (micropore-induced capillarity had the potential to enhance bone growth in vivo. This work illustrates the positive effects of capillarity on bone regeneration in vivo; it demonstrates that micropore-induced capillarity significantly
Zicaro, Juan Pablo; Yacuzzi, Carlos; Astoul Bonorino, Juan; Carbo, Lisandro; Costa-Paz, Matias
2017-12-01
This study evaluated the clinical and radiographic outcomes of a series of patients treated with an anatomic inlay resurfacing implant, with a minimum two-year follow-up. Fifteen patients underwent patellofemoral-resurfacing procedures using a HemiCAP Wave Patellofemoral Inlay Resurfacing implant from 2010 to 2013. Clinical outcomes included: Visual Analog Scale (VAS), Lysholm score, Knee Society Score (KSS), and evaluation of Kujala, and Hospital for Special Surgery Patellofemoral score (HSS-PF). The postoperative complications were analyzed. Nineteen knees were evaluated; the average follow-up was 35.2months. Fourteen were women, with an average age of 54years. The pre-operative/postoperative clinical results presented a significant improvement: VAS 8/2.5, Lysholm 31.9/85.8, KSS 39.8/82.5, Kujala 32.1/79.3 and Hospital for Special Surgery Patellofemoral score (HSS-PF) 15.9/90.6. A total of 87% of patients were either satisfied or very satisfied with the overall outcome. There were no radiographic signs of loosening. Seven postoperative complications were recorded: two presented ongoing knee pain, one postoperative stiffness, one patellar bounce due to maltracking, two ilio-tibial band syndrome, and one tibial anterior tuberosity osteotomy nonunion. Two patients underwent a total knee arthroplasty conversion and were considered a failure. None of these complications were implant related. Patellofemoral inlay resurfacing for isolated patellofemoral arthritis was an effective and safe procedure with high levels of patient satisfaction. No mechanical implant failure was seen at a minimum two-year follow-up. This implant design appeared to be an alternative to the traditional patellofemoral prostheses. Concomitant osteochondral lesions, patellofemoral dysplasia or patellar maltracking might be poor prognostic factors for this type of implant. Copyright © 2017 Elsevier B.V. All rights reserved.
Ng, Choong Hey; Yang, Kun-Lin
2016-01-01
Esterification of organic acids and alcohols in aqueous media is very inefficient due to thermodynamic constraints. However, fermentation processes used to produce organic acids and alcohols are often conducted in aqueous media. To produce esters in aqueous media, biphasic alginate beads with immobilized lipase are developed for in situ esterification of butanol and butyric acid. The biphasic beads contain a solid matrix of calcium alginate and hexadecane together with 5 mg/mL of lipase as the biocatalyst. Hexadecane in the biphasic beads serves as an organic phase to facilitate the esterification reaction. Under optimized conditions, the beads are able to catalyze the production of 0.16 mmol of butyl butyrate from 0.5 mmol of butyric acid and 1.5 mmol of butanol. In contrast, when monophasic beads (without hexadecane) are used, only trace amount of butyl butyrate is produced. One main application of biphasic beads is in simultaneous fermentation and esterification (SFE) because the organic phase inside the beads is very stable and does not leach out into the culture medium. SFE is successfully conducted with an esterification yield of 6.32% using biphasic beads containing iso-octane even though the solvent is proven toxic to the butanol-producing Clostridium spp. Copyright © 2015 Elsevier Inc. All rights reserved.
A new kinetic biphasic approach applied to biodiesel process intensification
Energy Technology Data Exchange (ETDEWEB)
Russo, V.; Tesser, R.; Di Serio, M.; Santacesaria, E. [Naples Univ. (Italy). Dept. of Chemistry
2012-07-01
Many different papers have been published on the kinetics of the transesterification of vegetable oil with methanol, in the presence of alkaline catalysts to produce biodiesel. All the proposed approaches are based on the assumption of a pseudo-monophasic system. The consequence of these approaches is that some experimental aspects cannot be described. For the reaction performed in batch conditions, for example, the monophasic approach is not able to reproduce the different plateau obtained by using different amount of catalyst or the induction time observed at low stirring rates. Moreover, it has been observed by operating in continuous reactors that micromixing has a dramatic effect on the reaction rate. At this purpose, we have recently observed that is possible to obtain a complete conversion to biodiesel in less than 10 seconds of reaction time. This observation is confirmed also by other authors using different types of reactors like: static mixers, micro-reactors, oscillatory flow reactors, cavitational reactors, microwave reactors or centrifugal contactors. In this work we will show that a recently proposed biphasic kinetic approach is able to describe all the aspects before mentioned that cannot be described by the monophasic kinetic model. In particular, we will show that the biphasic kinetic model can describe both the induction time observed in the batch reactors, at low stirring rate, and the very high conversions obtainable in a micro-channel reactor. The adopted biphasic kinetic model is based on a reliable reaction mechanism that will be validated by the experimental evidences reported in this work. (orig.)
In vitro study on biomineralization of biphasic calcium phosphate ...
Indian Academy of Sciences (India)
In this study, we report the preparation of a bone graft material, having cylindrical shape, containing biphasic calcium phosphate (BCP), gelatin (G), chitosan (C) and Terminalia chebula (TC) extract. TC extract was used as a crosslinker that gives stability to bone graft when it is placed in SBF. The graft was stable in the SBF ...
Trpkov, Kiril; Athanazio, Daniel; Magi-Galluzzi, Cristina; Yilmaz, Helene; Clouston, David; Agaimy, Abbas; Williamson, Sean R; Brimo, Fadi; Lopez, Jose I; Ulamec, Monika; Rioux-Leclercq, Nathalie; Kassem, Maysoun; Gupta, Nilesh; Hartmann, Arndt; Leroy, Xavier; Bashir, Samir Al; Yilmaz, Asli; Hes, Ondřej
2018-04-01
To further characterise biphasic squamoid renal cell carcinoma (RCC), a recently proposed variant of papillary RCC. We identified 28 tumours from multiple institutions. They typically showed two cell populations-larger cells with eosinophilic cytoplasm and higher-grade nuclei, surrounded by smaller, amphophilic cells with scanty cytoplasm. The dual morphology was variable (median 72.5% of tumour, range 5-100%); emperipolesis was found in all cases. The male/female ratio was 2:1, and the median age was 55 years (range 39-86 years). The median tumour size was 20 mm (range 9-65 mm). Pathological stage pT1a was found in 21 cases, pT1b in three, and pT3a and pT3b in one each (two not available). Multifocality was found in 32%: multifocal biphasic RCC in one case, biphasic + papillary RCC in two cases, biphasic + clear cell RCC in three cases, biphasic + low-grade urothelial carcinoma of the renal pelvis in one case, and biphasic + Birt-Hogg-Dubé syndrome in one case. Positive immunostains included: PAX8, cytokeratin (CK) 7, α-methylacyl-CoA racemase, epithelial membrane antigen, and vimentin. Cyclin D1 was expressed only in the larger cells. The Ki67 index was higher in the larger cells (median 5% versus ≤1%). Negative stains included: carbonic anhydrase 9, CD117, GATA-3, WT1, CK5/6, and CK20; CD10 and 34βE12 were variably expressed. Gains of chromosomes 7 and 17 were found in two evaluated cases. Follow-up was available for 23 patients (median 24 months, range 1-244 months): 19 were alive without disease, one was alive with recurrence, and one had died of disease (two had died of other causes). Biphasic papillary RCC is a rare variant of papillary RCC, and is often multifocal. © 2017 John Wiley & Sons Ltd.
Osteochondritis Dissecans of the Hip
International Nuclear Information System (INIS)
Linden, B.; Jonsson, K.; Redlund-Johnell, I.
2003-01-01
Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended
Osteochondritis Dissecans of the Hip
Energy Technology Data Exchange (ETDEWEB)
Linden, B. [Hoeglands Hospital, Eksjoe (Sweden). Dept. of Orthopedic Surgery; Jonsson, K. [Univ. Hospital, Lund (Sweden). Center for Medical Imaging and Physiology; Redlund-Johnell, I. [Univ. Hospital, Malmoe (Sweden). Dept. of Diagnostic Radiology
2003-03-01
Purpose: To investigate the clinical and radiological characteristics of osteochondritis dissecans (OD) of the hip and the outcome of this condition after treatment. Material and Methods: Twelve male and 3 female patients with OD were retrospectively studied. Six patients had a history of Legg-Calve-Perthes disease (LCPD) and among them 2 also had had a trauma to the hip. A further 5 had had trauma and 1 a developmental dislocation of the hip (DDH). The remaining 3 patients had no history of previous hip disease or trauma. All patients were examined with plain radiography, 7 with MR, 3 with CT and 2 with hip arthrography. Results: All OD lesions were detected at plain radiography, and most of them were located near the fovea. At MR the lesions had low signal intensity at T1-weighted sequences, and 6/7 had edema or fluid collection in or adjacent to the lesion on T2-weighted sequences. The early treatment in 7 patients was surgery, 2 had had conservative treatment and 6 no treatment. At follow-up 12 years after radiological diagnosis, 5 patients had hip arthrosis, 4 of whom were treated with arthroplasty. All but 3 had reduced hip rotation and all but 2 (with arthroplasty) had load pain. Three of the patients with earlier surgery had not developed arthrosis. Conclusions: OD lesions are usually well seen with plain radiography. There is a great risk of developing early arthrosis and it seems that early surgery is connected with arthrosis development. Thus only symptomatic treatment is recommended.
International Nuclear Information System (INIS)
Shim, Jin-Hyung; Lee, Jung-Seob; Cho, Dong-Woo; Kim, Jong Young
2012-01-01
The aim of this study was to build a mechanically enhanced three-dimensional (3D) bioprinted construct containing two different cell types for osteochondral tissue regeneration. Recently, the production of 3D cell-laden structures using various scaffold-free cell printing technologies has opened up new possibilities. However, ideal 3D complex tissues or organs have not yet been printed because gel-state hydrogels have been used as the principal material and are unable to maintain the desired 3D structure due to their poor mechanical strength. In this study, thermoplastic biomaterial polycaprolactone (PCL), which shows relatively high mechanical properties as compared with hydrogel, was used as a framework for enhancing the mechanical stability of the bioprinted construct. Two different alginate solutions were then infused into the previously prepared framework consisting of PCL to create the 3D construct for osteochondral printing. For this work, a multi-head tissue/organ building system (MtoBS), which was particularly designed to dispense thermoplastic biomaterial and hydrogel having completely different rheology properties, was newly developed and used to bioprint osteochondral tissue. It was confirmed that the line width, position and volume control of PCL and alginate solutions were adjustable in the MtoBS. Most importantly, dual cell-laden 3D constructs consisting of osteoblasts and chondrocytes were successfully fabricated. Further, the separately dispensed osteoblasts and chondrocytes not only retained their initial position and viability, but also proliferated up to 7 days after being dispensed. (paper)
Shim, Jin-Hyung; Lee, Jung-Seob; Kim, Jong Young; Cho, Dong-Woo
2012-08-01
The aim of this study was to build a mechanically enhanced three-dimensional (3D) bioprinted construct containing two different cell types for osteochondral tissue regeneration. Recently, the production of 3D cell-laden structures using various scaffold-free cell printing technologies has opened up new possibilities. However, ideal 3D complex tissues or organs have not yet been printed because gel-state hydrogels have been used as the principal material and are unable to maintain the desired 3D structure due to their poor mechanical strength. In this study, thermoplastic biomaterial polycaprolactone (PCL), which shows relatively high mechanical properties as compared with hydrogel, was used as a framework for enhancing the mechanical stability of the bioprinted construct. Two different alginate solutions were then infused into the previously prepared framework consisting of PCL to create the 3D construct for osteochondral printing. For this work, a multi-head tissue/organ building system (MtoBS), which was particularly designed to dispense thermoplastic biomaterial and hydrogel having completely different rheology properties, was newly developed and used to bioprint osteochondral tissue. It was confirmed that the line width, position and volume control of PCL and alginate solutions were adjustable in the MtoBS. Most importantly, dual cell-laden 3D constructs consisting of osteoblasts and chondrocytes were successfully fabricated. Further, the separately dispensed osteoblasts and chondrocytes not only retained their initial position and viability, but also proliferated up to 7 days after being dispensed.
International Nuclear Information System (INIS)
Ghanaati, Shahram; Barbeck, Mike; Hilbig, Ulrike; Rausch, Vera; Unger, Ronald E; Kirkpatrick, Charles James; Detsch, Rainer; Ziegler, Guenter; Deisinger, Ulrike; Sader, Robert
2012-01-01
Bone substitute material properties such as granule size, macroporosity, microporosity and shape have been shown to influence the cellular inflammatory response to a bone substitute material. Keeping these parameters constant, the present study analyzed the in vivo tissue reaction to three bone substitute materials (granules) with different chemical compositions (hydroxyapatite (HA), beta-tricalcium phosphate (TCP) and a mixture of both with a HA/TCP ratio of 60/40 wt%). Using a subcutaneous implantation model in Wistar rats for up to 30 days, tissue reactions, including the induction of multinucleated giant cells and the extent of implantation bed vascularization, were assessed using histological and histomorphometrical analyses. The results showed that the chemical composition of the bone substitute material significantly influenced the cellular response. When compared to HA, TCP attracted significantly greater multinucleated giant cell formations within the implantation bed. Furthermore, the vascularization of the implantation bed of TCP was significantly higher than that of HA implantation beds. The biphasic bone substitute group combined the properties of both groups. Within the first 15 days, high giant cell formation and vascularization rates were observed, which were comparable to the TCP-group. However, after 15 days, the tissue reaction, i.e. the extent of multinucleated giant cell formation and vascularization, was comparable to the HA-group. In conclusion, the combination of both compounds HA and TCP may be a useful combination for generating a scaffold for rapid vascularization and integration during the early time points after implantation and for setting up a relatively slow degradation. Both of these factors are necessary for successful bone tissue regeneration.
Lesion Size Does Not Predict Outcomes in Fresh Osteochondral Allograft Transplantation.
Tírico, Luis E P; McCauley, Julie C; Pulido, Pamela A; Bugbee, William D
2018-03-01
Cartilage repair algorithms use lesion size to choose surgical techniques when selecting a cartilage repair procedure. The association of fresh osteochondral allograft (OCA) size with graft survivorship and subjective patient outcomes is still unknown. To determine if lesion size (absolute or relative) affects outcomes after OCA transplantation. Cohort study; Level of evidence, 3. The study included 156 knees in 143 patients who underwent OCA transplantation from 1998 to 2014 for isolated femoral condyle lesions. The mean age was 29.6 ± 11.4 years, and 62.9% were male. The majority of patients (62.2%) presented for cartilage repair because of osteochondritis dissecans. The mean graft area, used as a surrogate for absolute size of the lesion, was 6.4 cm 2 (range, 2.3-11.5 cm 2 ). The relative size of the lesion was calculated as the tibial width ratio (TWR; ratio of graft area to tibial width) and affected femoral condyle ratio (AFCR; ratio of graft area to affected femoral condyle width) using preoperative radiographs. All patients had a minimum follow-up of 2 years. Further surgical procedures were documented, and graft failure was defined as revision OCA transplantation or conversion to arthroplasty. International Knee Documentation Committee (IKDC) pain, function, and total scores were obtained. Satisfaction with OCA transplantation was assessed. The mean follow-up among patients with grafts remaining in situ was 6.0 years (range, 1.9-16.5 years). The OCA failure rate was 5.8%. Overall survivorship of the graft was 97.2% at 5 years and 93.5% at 10 years. No difference in postoperative outcomes between groups was found in absolute or relative size. Change in IKDC scores (from preoperative to latest follow-up) was greater for knees with large lesions compared to knees with small lesions, among all measurement methods. Overall satisfaction with the results of OCA transplantation was 89.8%. The size of the lesion, either absolute or relative, does not influence
CO2 Absorption by Biphasic Solvents: Comparison with Lower Phase Alone
International Nuclear Information System (INIS)
Xu, Zhicheng; Wang, Shujuan; Qi, Guojie; Liu, Jinzhao; Zhao, Bo; Chen, Changhe
2014-01-01
The mixtures of 2 M 1,4-butanediamine (BDA) and 4 M 2-(diethylamino)-ethanol (DEEA) have been found to be promising biphasic solvents. This work identifies the composition of the lower phase using a DX-120 Ion Chromatograph (IC) and a Metrohm 809 Titrando auto titrator. The cyclic capacities, cyclic loadings and reaction products of the biphasic solvent are compared with those of the aqueous solution with the same amine concentration as the lower phase of the biphasic solvent at the rich loading ((2B4D) L ) using a fast screening facility and a JNM ECA-600 Nuclear Magnetic Resonance spectrometer (NMR). Their absorption rates at different loadings are also investigated using a Wetted Wall Column (WWC). The results show that the cyclic capacity and cyclic loading of (2B4D) L are almost the same as those of 2B4D. The absorption rate of (2B4D) L is higher than 2B4D at all the 3 tested loadings, except for the fresh solutions at CO 2 pressure lower than 10 kPa. NMR results show that the reaction products of (2B4D) L had more BDA bi-carbamate, less BDA and less BDA carbamate than 2B4D. The CO 2 reaction products of (2B4D) L had twice as much carbonate/bicarbonate as with 2B4D and less BDA carbamate. (authors)
Lang, Hayley M; Nixon, Alan J
2015-05-01
To characterize discrete palmar carpal osteochondral fragmentation in horses and to document the effect of osteoarthritis and surgical removal of these fragments on functional outcome. Retrospective case series. 25 horses. Medical records and radiographic views were reviewed to identify horses that had radiographic evidence of palmar carpal fragmentation, which was subsequently treated by arthroscopic removal. Information collected included cause of fracture, initial and long-term clinical and radiographic findings, and functional outcome. Palmar carpal fragmentation of 30 carpal bones was identified in 25 unilaterally affected horses. A known traumatic event was reported to cause the fragmentation in 17 of the 25 (68%) horses. Of the 25 horses, 17 (68%) had fragmentation involving the antebrachiocarpal joint, 7 (28%) had fragmentation involving the middle carpal joint, and 1 (4%) had fragmentation involving the carpometacarpal joint. The proximal aspect of the radial carpal bone was the most commonly affected site (12/30 fragments), followed by the accessory carpal bone (6/30). Of the 25 horses, 19 (76%) were not lame (sound) after surgery and returned to their intended use, 4 (16%) were considered pasture sound, and 2 were euthanized (because of severe postoperative osteoarthritis or long bone fracture during recovery from anesthesia). Eight of the 14 horses with preoperative evidence of osteoarthritis returned to function after surgery. Twelve of 17 horses with antebrachiocarpal joint fragments and 6 of 7 horses with middle carpal joint fragments returned to their previous use. Results indicated that the prognosis for horses after arthroscopic removal of palmar carpal osteochondral fragments is good. Early intervention, before the development of osteoarthritis, is recommended.
Reesink, Heidi L
2017-08-01
Foals are susceptible to many of the same types of fractures as adult horses, often secondary to external sources of trauma. In addition, some types of fractures are specific to foals and occur routinely in horses under 1 year of age. These foal-specific fractures may be due to the unique musculoskeletal properties of the developing animal and may present with distinct clinical signs. Treatment plans and prognoses are tailored specifically to young animals. Common fractures not affecting the long bones in foals are discussed in this article, including osteochondral fragmentation, proximal sesamoid bone fractures/sesamoiditis, and distal phalanx fractures. Copyright © 2017 Elsevier Inc. All rights reserved.
Directory of Open Access Journals (Sweden)
Francesco Guido Mangano
2014-01-01
Full Text Available The aim of this study was to achieve aesthetically pleasing soft tissue contours in a severely compromised tooth in the anterior region of the maxilla. For a right-maxillary central incisor with localized advanced chronic periodontitis a tooth extraction followed by reconstructive procedures and delayed implant placement was proposed and accepted by the patient. Guided bone regeneration (GBR technique was employed, with a biphasic calcium-phosphate (BCP block graft placed in the extraction socket in conjunction with granules of the same material and a resorbable barrier membrane. After 6 months of healing, an implant was installed. The acrylic provisional restoration remained in situ for 3 months and then was substituted with the definitive crown. This ridge reconstruction technique enabled preserving both hard and soft tissues and counteracting vertical and horizontal bone resorption after tooth extraction and allowed for an ideal three-dimensional implant placement. Localized severe alveolar bone resorption of the anterior maxilla associated with chronic periodontal disease can be successfully treated by means of ridge reconstruction with GBR and delayed implant insertion; the placement of an early-loaded, Morse taper connection implant in the grafted site was effective to create an excellent clinical aesthetic result and to maintain it along time.
International Nuclear Information System (INIS)
Hughes, Jacqueline A.; Cook, Jane V.; Warren, Mary E.; Churchill, Mark A.
2003-01-01
Although MRI prognostic features for juvenile osteochondritis dissecans (JOCD) have been determined, the natural history of JOCD on serial MRI has not been fully documented. To document the natural history of JOCD on serial MRI and to correlate this with arthroscopy and clinical outcome over a 5-year follow-up. Twenty-one knees in 19 patients (15 boys, 4 girls; age range 5-15 years) with JOCD underwent MRI and clinical follow-up over 5 years. Lesions were classified as stable or unstable on MRI and compared with clinical and arthroscopic data. On 5-year follow-up, 17 of 19 patients were asymptomatic and 2 of 19 had minimal pain. Fourteen arthroscopies were performed on 11/21 knees. One of twenty-one had fragment fixation. On initial MRI, eight knees had marked fragmentation, high signal at the fragment/bone interface and incomplete defects in the hyaline cartilage (MRI stage III-stable), but no tear. Of these, five had arthroscopy, all confirming intact cartilage. One of twenty-one knees was unstable (MRI stage IVb) with a detached osteochondral fragment, requiring surgery. Despite extensive subchondral bone changes on MRI, all cases with intact cartilage (95%) improved with conservative treatment. Early MRI allows prompt diagnosis and institution of conservative treatment. This results in healing and avoidance of surgery in most patients. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Hughes, Jacqueline A.; Cook, Jane V.; Warren, Mary E. [Radiology Department, Queen Mary' s Hospital for Children, Epsom and St Helier NHS Trust, Carshalton, Surrey SM5 1AA (United Kingdom); Churchill, Mark A. [Orthopaedic Department, Queen Mary' s Hospital for Children, Epsom and St Helier NHS Trust, Carshalton (United Kingdom)
2003-06-01
Although MRI prognostic features for juvenile osteochondritis dissecans (JOCD) have been determined, the natural history of JOCD on serial MRI has not been fully documented. To document the natural history of JOCD on serial MRI and to correlate this with arthroscopy and clinical outcome over a 5-year follow-up. Twenty-one knees in 19 patients (15 boys, 4 girls; age range 5-15 years) with JOCD underwent MRI and clinical follow-up over 5 years. Lesions were classified as stable or unstable on MRI and compared with clinical and arthroscopic data. On 5-year follow-up, 17 of 19 patients were asymptomatic and 2 of 19 had minimal pain. Fourteen arthroscopies were performed on 11/21 knees. One of twenty-one had fragment fixation. On initial MRI, eight knees had marked fragmentation, high signal at the fragment/bone interface and incomplete defects in the hyaline cartilage (MRI stage III-stable), but no tear. Of these, five had arthroscopy, all confirming intact cartilage. One of twenty-one knees was unstable (MRI stage IVb) with a detached osteochondral fragment, requiring surgery. Despite extensive subchondral bone changes on MRI, all cases with intact cartilage (95%) improved with conservative treatment. Early MRI allows prompt diagnosis and institution of conservative treatment. This results in healing and avoidance of surgery in most patients. (orig.)
Czech Academy of Sciences Publication Activity Database
Polanská, M.; Hulejová, H.; Petrtýl, M.; Bastl, Zdeněk; Spirovová, Ilona; Kruliš, Zdeněk; Horák, Zdeněk; Veigl, D.; Šenolt, L.
2010-01-01
Roč. 59, č. 2 (2010), s. 247-253 ISSN 0862-8408 R&D Projects: GA ČR GA106/06/0761 Institutional research plan: CEZ:AV0Z40400503; CEZ:AV0Z40500505 Keywords : osteochondral defects * cycloolefin copolymer * chondrocytes * biocompatibility Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.646, year: 2010
Directory of Open Access Journals (Sweden)
Francesco Guido Mangano
2015-01-01
Full Text Available This report documents the clinical, radiographic, and histologic outcome of a custom-made computer-aided-design/computer-aided-manufactured (CAD/CAM scaffold used for the alveolar ridge augmentation of a severely atrophic anterior mandible. Computed tomographic (CT images of an atrophic anterior mandible were acquired and modified into a 3-dimensional (3D reconstruction model; this was transferred to a CAD program, where a custom-made scaffold was designed. CAM software generated a set of tool-paths for the manufacture of the scaffold on a computer-numerical-control milling machine into the exact shape of the 3D design. A custom-made scaffold was milled from a synthetic micromacroporous biphasic calcium phosphate (BCP block. The scaffold closely matched the shape of the defect: this helped to reduce the time for the surgery and contributed to good healing. One year later, newly formed and well-integrated bone was clinically available, and two implants (AnyRidge, MegaGen, Gyeongbuk, South Korea were placed. The histologic samples retrieved from the implant sites revealed compact mature bone undergoing remodelling, marrow spaces, and newly formed trabecular bone surrounded by residual BCP particles. This study demonstrates that custom-made scaffolds can be fabricated by combining CT scans and CAD/CAM techniques. Further studies on a larger sample of patients are needed to confirm these results.
Tong, Shengqiang
2010-01-01
This work concentrates on a novel chiral separation technology named biphasic recognition applied to resolution of α-cyclohexylmandelic acid enantiomers by high-speed counter-current chromatography (HSCCC). The biphasic chiral recognition HSCCC was performed by adding lipophilic (−)-2-ethylhexyl tartrate in the organic stationary phase and hydrophilic hydroxypropyl-β-cyclodextrin in the aqueous mobile phase, which preferentially recognized the (−)-enantiomer and (+)-enantiomer, respectively. The two-phase solvent system composed of n-hexane-methyl tert-butyl ether-water (9:1:10, v/v/v) with the above chiral selectors was selected according to the partition coefficient and separation factor of the target enantiomers. Various parameters involved in the chiral separation were investigated, namely the types of the chiral selector (CS); the concentration of each chiral selector; pH of the mobile phase; and the separation temperature. The mechanism involved in this biphasic recognition chiral separation by HSCCC was discussed. Langmuirian isotherm was employed to estimate the loading limits for each chiral selector. The overall experimental results show that the HSCCC separation of enantiomer based on biphasic recognition is much more efficient than the traditional monophasic recognition chiral separation, since it utilizes the cooperation of both lipophilic and hydrophilic chiral selectors. PMID:20303497
Directory of Open Access Journals (Sweden)
Hilbe Monika
2005-12-01
Full Text Available Abstract Background Differences in overall performance of osteochondral photooxidized grafts were studied in accordance of their species origin and a new, more rigorous cleansing procedure using alcohol during preparation. Methods Photooxidized mushroom-shaped grafts of bovine, ovine, human and equine origin were implanted in the femoral condyles of 32 sheep (condyles: n = 64. No viable chondrocytes were present at the time of implantation. Grafts were evaluated at 6 months using plastic embedded sections of non-decalcified bone and cartilage specimens. Graft incorporation, the formation of cyst-like lesions at the base of the cartilage junction as well as cartilage morphology was studied qualitatively, semi-quantitatively using a score system and quantitatively by performing histomorphometrical measurements of percentage of bone and fibrous tissue of the original defects. For statistical analysis a factorial analysis of variance (ANOVA- test was applied. Results Differences of graft performance were found according to species origin and cleansing process during graft preparation. According to the score system cartilage surface integrity was best for equine grafts, as well as dislocation or mechanical stability. The equine grafts showed the highest percentage for bone and lowest for fibrous tissue, resp. cystic lesions. The new, more rigorous cleansing process decreased cartilage persistence and overall graft performance. Conclusion Performance of grafts from equine origin was better compared to bovine, ovine and human grafts. The exact reason for this difference was not proven in the current study, but could be related to differences in density of cartilage and subchondral bone between species.
Energy Technology Data Exchange (ETDEWEB)
Arahira, Takaaki; Maruta, Michito, E-mail: maruta@college.fdcnet.ac.jp; Matsuya, Shigeki
2017-05-01
Biphasic calcium phosphate consisting of hydroxyapatite (HA) and β-tricalcium phosphate(β-TCP) is an excellent bone substitute with controllable bioresorbability. Fabrication of biphasic calcium phosphate with self-setting ability is expected to enhance its potential application as bone substitute. In this study, mixtures of α-TCP and β-TCP with various compositions were prepared through α-β phase transition of α-TCP powder at 1000 °C for various periods. These powders were mixed with 0.25 M Na{sub 2}HPO{sub 4} at a P/L ratio of 2, and then hardened at 37 °C at 100% RH for up to 24 h. Material properties of biphasic HA/β-TCP cement with different α-TCP/β-TCP composition were characterized. These cements were also evaluated with respect to cell response in vitro using MC3T3-E1 cell lines. In conclusion, mechanical and biological properties of HA/β-TCP cement could be controlled by changing the heat treatment time of α-TCP powder at 1000 °C. In vitro results indicated that cell proliferation and ALP activity increased with increase β-TCP content. - Highlights: • We could fabricate biphasic HA/β-TCP cements using heat treated α-TCP powder. • It is easy to control the ratio of α-TCP to β-TCP changing the heat treatment time up to 48 h. • Both cell number and ALP activity increased with increase in β-TCP content. • In vitro results showed that β-TCP has superior cell affinity to HA.
Bansal, Shyam S.; Kausar, Hina; Vadhanam, Manicka V.; Ravoori, Srivani; Gupta, Ramesh C.
2012-01-01
Curcumin possess potent anti-inflammatory and anti-proliferative activities but with poor biopharmaceutical attributes. To overcome these limitations, curcumin implants were developed and tissue (plasma, brain and liver) curcumin concentrations were measured in female ACI rats for 3 months. Biological efficacy of tissue levels achieved was analyzed by modulation of hepatic cytochromes. Curcumin implants exhibited diffusion-mediated biphasic release pattern with ~2-fold higher in vivo release as compared to in vitro. Plasma curcumin concentration from implants was ~3.3 ng/ml on day 1 which dropped to ~0.2 ng/ml after 3 months whereas only 0.2–0.3 ng/ml concentration was observed from 4–12 days with diet and was undetected subsequently. Almost 10 fold higher curcumin levels were observed in brain on day 1 from implants compared with diet (30.1±7.3 vs 2.7±0.8 ng/g) and were higher even after 90 days (7.7±3.8 vs 2.2±0.8 ng/g). Although, curcumin levels were similar in liver from both the routes (~25–30 ng/g from day 1–4 and ~10–15 ng/g at 90 days), implants were more efficacious in altering hepatic CYP1A1 levels and CYP3A4 activity at ~28 fold lower doses. Curcumin implants provided much higher plasma and tissue concentrations and are a viable alternative for delivery of curcumin to various organs like brain. PMID:22227368
Jurgens, W.J.F.M.; Kroeze, R.J.; Zandieh-Doulabi, B.; van Dijk, A.; Renders, G.A.P.; Smit, T.H.; van Milligen, F.J.; Ritt, M.J.P.F.
2013-01-01
Regenerative therapies offer attractive alternatives for the treatment of osteochondral defects. Adipose-derived stromal vascular fraction (SVF) cells allow the development of one-step surgical procedures by their abundant availability and high frequency. In this pilot study we evaluated the in vivo
Yuan, XiaoDong; Zhang, Jing; Quan, ChangBin; Tian, Yuan; Li, Hong; Ao, GuoKun
2016-04-01
To determine the feasibility and accuracy of a protocol for calculating whole-organ renal perfusion (renal blood flow [RBF]) and regional perfusion on the basis of biphasic computed tomography (CT), with concurrent dynamic contrast material-enhanced (DCE) CT perfusion serving as the reference standard. This prospective study was approved by the institutional review board, and written informed consent was obtained from all patients. Biphasic CT of the kidneys, including precontrast and arterial phase imaging, was integrated with a first-pass dynamic volume CT protocol and performed and analyzed in 23 patients suspected of having renal artery stenosis. The perfusion value derived from biphasic CT was calculated as CT number enhancement divided by the area under the arterial input function and compared with the DCE CT perfusion data by using the paired t test, correlation analysis, and Bland-Altman plots. Correlation analysis was made between the RBF and the extent of renal artery stenosis. All postprocessing was independently performed by two observers and then averaged as the final result. Mean ± standard deviation biphasic and DCE CT perfusion data for RBF were 425.62 mL/min ± 124.74 and 419.81 mL/min ± 121.13, respectively (P = .53), and for regional perfusion they were 271.15 mL/min per 100 mL ± 82.21 and 266.33 mL/min per 100 mL ± 74.40, respectively (P = .31). Good correlation and agreement were shown between biphasic and DCE CT perfusion for RBF (r = 0.93; ±10% variation from mean perfusion data [P < .001]) and for regional perfusion (r = 0.90; ±13% variation from mean perfusion data [P < .001]). The extent of renal artery stenosis was negatively correlated with RBF with biphasic CT perfusion (r = -0.81, P = .012). Biphasic CT perfusion is clinically feasible and provides perfusion data comparable to DCE CT perfusion data at both global and regional levels in the kidney. Online supplemental material is available for this article.
Predictive feedback can account for biphasic responses in the lateral geniculate nucleus.
Directory of Open Access Journals (Sweden)
Janneke F M Jehee
2009-05-01
Full Text Available Biphasic neural response properties, where the optimal stimulus for driving a neural response changes from one stimulus pattern to the opposite stimulus pattern over short periods of time, have been described in several visual areas, including lateral geniculate nucleus (LGN, primary visual cortex (V1, and middle temporal area (MT. We describe a hierarchical model of predictive coding and simulations that capture these temporal variations in neuronal response properties. We focus on the LGN-V1 circuit and find that after training on natural images the model exhibits the brain's LGN-V1 connectivity structure, in which the structure of V1 receptive fields is linked to the spatial alignment and properties of center-surround cells in the LGN. In addition, the spatio-temporal response profile of LGN model neurons is biphasic in structure, resembling the biphasic response structure of neurons in cat LGN. Moreover, the model displays a specific pattern of influence of feedback, where LGN receptive fields that are aligned over a simple cell receptive field zone of the same polarity decrease their responses while neurons of opposite polarity increase their responses with feedback. This phase-reversed pattern of influence was recently observed in neurophysiology. These results corroborate the idea that predictive feedback is a general coding strategy in the brain.
Kitamura, Nobuto; Yasuda, Kazunori; Ogawa, Munehiro; Arakaki, Kazunobu; Kai, Shuken; Onodera, Shin; Kurokawa, Takayuki; Gong, Jian Ping
2011-06-01
A double-network (DN) gel, which was composed of poly-(2-acrylamido-2-methylpropanesulfonic acid) and poly-(N,N'-dimetyl acrylamide) (PAMPS/PDMAAm), has the potential to induce chondrogenesis both in vitro and in vivo. To establish the efficacy of a therapeutic strategy for an articular cartilage defect using a DN gel. Controlled laboratory study. A 4.3-mm-diameter osteochondral defect was created in rabbit trochlea. A DN gel plug was implanted into the defect of the right knee so that a defect 2 mm in depth remained after surgery. An untreated defect of the left knee provided control data. The osteochondral defects created were examined by histological and immunohistochemical evaluations, surface assessment using confocal laser scanning microscopy, and real-time polymerase chain reaction (PCR) analysis at 4 and 12 weeks. Samples were quantitatively evaluated with 2 scoring systems reported by Wayne et al and O'Driscoll et al. The DN gel-implanted defect was filled with a sufficient volume of the hyaline cartilage tissue rich in proteoglycan and type 2 collagen. Quantitative evaluation using the grading scales revealed a significantly higher score in the DN gel-implanted defects compared with the untreated control at each period (P cartilage at 12 weeks (P = .0106), while there was no statistical difference between the DN gel-implanted and normal knees. This study using the mature rabbit femoral trochlea osteochondral defect model demonstrated that DN gel implantation is an effective treatment to induce cartilage regeneration in vivo without any cultured cells or mammalian-derived scaffolds. This study has prompted us to develop a potential innovative strategy to repair cartilage lesions in the field of joint surgery.
A simulation study of the reaction of human heart to biphasic electrical shocks
Directory of Open Access Journals (Sweden)
Seemann Gunnar
2004-06-01
Full Text Available Abstract Background This article presents a study, which examines the effects of biphasic electrical shocks on human ventricular tissue. The effects of this type of shock are not yet fully understood. Animal experiments showed the superiority of biphasic shocks over monophasic ones in defibrillation. A mathematical computer simulation can increase the knowledge of human heart behavior. Methods The research presented in this article was done with different models representing a three-dimensional wedge of ventricular myocardium. The electrophysiology was described with Priebe-Beuckelmann model. The realistic fiber twist, which is specific to human myocardium was included. Planar electrodes were placed at the ends of the longest side of the virtual cardiac wedge, in a bath medium. They were sources of electrical shocks, which varied in magnitude from 0.1 to 5 V. In a second arrangement ring electrodes were placed directly on myocardium for getting a better view on secondary electrical sources. The electrical reaction of the tissue was generated with a bidomain model. Results The reaction of the tissue to the electrical shock was specific to the initial imposed characteristics. Depolarization appeared in the first 5 ms in different locations. A further study of the cardiac tissue behavior revealed, which features influence the response of the considered muscle. It was shown that the time needed by the tissue to be totally depolarized is much shorter when a biphasic shock is applied. Each simulation ended only after complete repolarization was achieved. This created the possibility of gathering information from all states corresponding to one cycle of the cardiac rhythm. Conclusions The differences between the reaction of the homogeneous tissue and a tissue, which contains cleavage planes, reveals important aspects of superiority of biphasic pulses. ...
Beck, Sascha; Cla?en, Tim; Haversath, Marcel; J?ger, Marcus; Landgraeber, Stefan
2016-01-01
Background Revitalizing the necrotic subchondral bone and preserving the intact cartilage layer by retrograde drilling is the preferred option for treatment of undetached osteochondral lesions of the talus (OLT). We assessed the effectiveness of Endoscopic Core Decompression (ECD) in treatment of OLT. Material/Methods Seven patients with an undetached OLT of the medial talar dome underwent surgical treatment using an arthroscopically-guided transtalar drill meatus for core decompression of th...
Learning new meanings for known words: Biphasic effects of prior knowledge
Fang, Xiaoping; Perfetti, Charles; Stafura, Joseph
2017-01-01
In acquiring word meanings, learners are often confronted by a single word form that is mapped to two or more meanings. For example, long after how to roller-“skate”, one may learn that “skate” is also a kind of fish. Such learning of new meanings for familiar words involves two potentially contrasting processes, relative to new form-new meaning learning: 1) Form-based familiarity may facilitate learning a new meaning, and 2) meaning-based interference may inhibit learning a new meaning. We examined these two processes by having native English speakers learn new, unrelated meanings for familiar (high frequency) and less familiar (low frequency) English words, as well as for unfamiliar (novel or pseudo-) words. Tracking learning with cued-recall tasks at several points during learning revealed a biphasic pattern: higher learning rates and greater learning efficiency for familiar words relative to novel words early in learning and a reversal of this pattern later in learning. Following learning, interference from original meanings for familiar words was detected in a semantic relatedness judgment task. Additionally, lexical access to familiar words with new meanings became faster compared to their exposure controls, but no such effect occurred for less familiar words. Overall, the results suggest a biphasic pattern of facilitating and interfering processes: Familiar word forms facilitate learning earlier, while interference from original meanings becomes more influential later. This biphasic pattern reflects the co-activation of new and old meanings during learning, a process that may play a role in lexicalization of new meanings. PMID:29399593
The X-ray and MRI diagnosis of osteochondritis dissecans in the knee joint
International Nuclear Information System (INIS)
Ge Xihong; Wang Bin; Sun Xihe; Chang Guanghui
2002-01-01
Objective: To investigate the X-ray and MRI manifestations of osteochondritis dissecans (OCD) and to compare the sensitivity of detection among different sequences. Methods: Thirty-six OCD cases (thirty-eight knees) with complete data were selected and analyzed. The sagittal and coronal images were acquired on T 1 WI, T 2 WI, PDWI and FLASH T 2 WI. MRI manifestations were analyzed retrospectively with double blind contrast method. The radiography were obtained on the same day. The sensitivity of detection among different sequences was also compared. Results: (1) The medial femoral condyle was the most commonly affected location in the knee (63.2%). The proportion of classical type, expanded type, and infero-central type was 55.3%, 15.8% and 28.9%, respectively. (2) On radiographs, the lesions typically appeared as a well circumscribed area of sclerotic subchondral bone separated from the remainder of the epiphysis by a radiolucent line. (3) Subchondral bone lesion was displayed as small and crescent-shaped (n = 38) on the sagittal image and as wedge (14) or short bar (24) shape on coronal image. The signal of the lesion was hypointense or isointense on T 1 WI, surrounded by a hypointense or hyperintense (FLASH T 2 WI, T 2 WI) line. The subchondral plate disappeared or became thinner. Interruption or disappearance of the hyaline cartilage could be seen sometimes. (4) The detection rate on T 1 WI was higher than that of PDWI, T 2 WI and FLASH T 2 WI. Conclusion: (1) Osteochondritis dissecans has specific X-ray and MRI manifestations. The abnormality of the hyaline cartilage and the subchondral bone can be displayed by MRI. Thus a proper diagnosis can be made. (2) The detection rate on T 1 WI is higher than that of PDWI, T 2 WI and FLASH T 2 WI
A case of mumps-related acute encephalopathy with biphasic seizures and late reduced diffusion.
Hazama, Kyoko; Shiihara, Takashi; Tsukagoshi, Hiroyuki; Hasegawa, Shunji; Dowa, Yuri; Watanabe, Mio
2017-10-01
Mumps is a common childhood viral disease characterized by fever and swelling of the parotid gland. The prognosis is generally good, although some complications, such as encephalitis (0.1%), exist. Acute encephalopathy with biphasic seizures and late reduced diffusion is the most common type of acute encephalopathy. However, this type of encephalopathy has not been reported in association with mumps infection. A previously healthy 3-year-old Japanese boy had a brief convulsion after fever for 3days, and then had conscious disturbance and parotitis. After several days, he had a second brief convulsion and was admitted. Increased serum amylase levels and presence of anti-mumps immunoglobulin M antibody confirmed mumps parotitis. The patient had another brief seizure later the day of admission. He did not have status or cluster seizures, although the biphasic nature of his seizures, conscious disturbance between the seizures, no pleocytosis in cerebrospinal fluid, and brain magnetic resonance images were consistent with acute encephalopathy with biphasic seizures and late reduced diffusion. In Japan, the mumps vaccine is not administered as a part of routine immunizations. It thus has low coverage (30-40%), and as a result, mumps infections are still common. However, this is the first case of mumps-related acute encephalopathy with biphasic seizures and late reduced diffusion. This case may be representative of only a minority of patients with mumps-associated central nervous system involvement. Nevertheless, this diagnostic possibility may be considered. In order to prevent mumps-related complications, routine mumps vaccination might be warranted. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Chen, Wen-Jing; Lou, Wen-Yong; Zong, Min-Hua
2012-07-01
The asymmetric hydrolysis of styrene oxide to (R)-1-phenyl-1,2-ethanediol using Mung bean epoxide hydrolases was, for the first time, successfully conducted in an ionic liquid (IL)-containing biphasic system. Compared to aqueous monophasic system, IL-based biphasic systems could not only dissolve the substrate, but also effectively inhibit the non-enzymatic hydrolysis, and therefore markedly improve the reaction efficiency. Of all the tested ILs, the best results were observed in the biphasic system containing C(4)MIM·PF(6), which exhibited good biocompatibility with the enzyme and was an excellent solvent for the substrate. In the C(4)MIM·PF(6)/buffer biphasic system, it was found that the optimal volume ratio of IL to buffer, reaction temperature, buffer pH and substrate concentration were 1/6, 35°C, 6.5 and 100 mM, respectively, under which the initial reaction rate, the yield and the product e.e. were 18.4 mM/h, 49.4% and 97.0%. The biocatalytic process was shown to be feasible on a 500-mL preparative scale. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kadarmideen, Haja N; Janss, Luc L G
2005-11-01
Bayesian segregation analyses were used to investigate the mode of inheritance of osteochondral lesions (osteochondrosis, OC) in pigs. Data consisted of 1163 animals with OC and their pedigrees included 2891 animals. Mixed-inheritance threshold models (MITM) and several variants of MITM, in conjunction with Markov chain Monte Carlo methods, were developed for the analysis of these (categorical) data. Results showed major genes with significant and substantially higher variances (range 1.384-37.81), compared to the polygenic variance (sigmau2). Consequently, heritabilities for a mixed inheritance (range 0.65-0.90) were much higher than the heritabilities from the polygenes. Disease allele frequencies range was 0.38-0.88. Additional analyses estimating the transmission probabilities of the major gene showed clear evidence for Mendelian segregation of a major gene affecting osteochondrosis. The variants, MITM with informative prior on sigmau2, showed significant improvement in marginal distributions and accuracy of parameters. MITM with a "reduced polygenic model" for parameterization of polygenic effects avoided convergence problems and poor mixing encountered in an "individual polygenic model." In all cases, "shrinkage estimators" for fixed effects avoided unidentifiability for these parameters. The mixed-inheritance linear model (MILM) was also applied to all OC lesions and compared with the MITM. This is the first study to report evidence of major genes for osteochondral lesions in pigs; these results may also form a basis for underpinning the genetic inheritance of this disease in other animals as well as in humans.
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems.
An, Jiwoo; Trujillo-Rodríguez, María J; Pino, Verónica; Anderson, Jared L
2017-06-02
The development of rapid, convenient, and high throughput sample preparation approaches such as liquid phase microextraction techniques have been continuously developed over the last decade. More recently, significant attention has been given to the replacement of conventional organic solvents used in liquid phase microextraction techniques in order to reduce toxic waste and to improve selectivity and/or extraction efficiency. With these objectives, non-conventional solvents have been explored in liquid phase microextraction and aqueous biphasic systems. The utilized non-conventional solvents include ionic liquids, magnetic ionic liquids, and deep eutectic solvents. They have been widely used as extraction solvents or additives in various liquid phase microextraction modes including dispersive liquid-liquid microextraction, single-drop microextraction, hollow fiber-liquid phase microextraction, as well as in aqueous biphasic systems. This review provides an overview into the use of non-conventional solvents in these microextraction techniques in the past 5 years (2012-2016). Analytical applications of the techniques are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Persistent bone marrow edema after osteochondral autograft transplantation in the knee joint
International Nuclear Information System (INIS)
Nemec, Stefan Franz; Marlovits, Stefan; Trattnig, Siegfried
2009-01-01
Background and objective: The assessment of bone marrow edema-like signal intensity in magnetic resonance imaging (MRI) in patients after osteochondral autograft transplantation (OCT) in the knee joint is a parameter of yet indefinite value. This study determines the prevalence of persistent edema-like signal intensity in OCT patients and evaluates the correlation between edema and morphological imaging findings of the graft and clinical pain symptoms. Materials and methods: In this longitudinal observational study, 10 patients after OCT were followed by MRI prospectively 1 month, 3 months, 6 months, 12 months, and 24 months post-operatively. All MR examinations were performed on a 1.0 T MR unit with the same protocol using a modified scoring system (magnetic resonance observation of cartilage repair tissue-MOCART) for evaluation. Edema-like signal intensity in and beneath the osteochondral graft was assessed in its prevalence and graded using a coronal short tau inversion recovery fast spin echo (STIR-FSE) sequence: grade 1, normal; grade 2, moderate (diameter 2 cm). The finding of edema-like signal intensity was correlated with graded parameters describing the morphology of the repair tissue assessed in a sagittal dual FSE sequence including: (a) surface of repair tissue: grade 1, intact; grade 2, damaged. (b) Cartilage interface: grade 1, complete; grade 2, incomplete. (c) Bone interface: grade 1, complete; grade 2, delamination. The finding of edema-like signal intensity was also correlated with the KOOS pain score assessing knee pain after 12 months. Results: Initially, after 1 month the prevalence of edema-like signal intensity was 70% (7/10 patients) and finally after 24 months 60% (6/10 patients). We found no significant relationship between the prevalence and degree of edema-like signal intensity and parameters describing the morphology of the repair tissue. Also the clinical pain score did not show significant correlation with edema. Conclusion
Czech Academy of Sciences Publication Activity Database
Filová, Eva; Rampichová, Michala; Handl, M.; Lytvynets, Andrej; Halouzka, R.; Usvald, Dušan; Hlučilová, Jana; Procházka, Radek; Dezortová, M.; Rolencová, E.; Košťáková, E.; Trč, T.; Šťastný, E.; Koláčná, Lucie; Hájek, M.; Motlík, Jan; Amler, Evžen
2007-01-01
Roč. 56, Suppl. 1 (2007), S5-S16 ISSN 0862-8408 R&D Projects: GA AV ČR(CZ) 1ET400110403; GA AV ČR IAA500390702; GA MŠk 2B06130; GA ČR(CZ) GA304/05/0327 Grant - others:-(CZ) 1M6798582302 Institutional research plan: CEZ:AV0Z50390512; CEZ:AV0Z50110509; CEZ:AV0Z50450515 Source of funding: V - iné verejné zdroje Keywords : Osteochondral defect * Fibrin * Autologous chondrocytes Subject RIV: BO - Biophysics Impact factor: 1.505, year: 2007
van Alem, Anouk P.; Chapman, Fred W.; Lank, Paula; Hart, Augustinus A. M.; Koster, Rudolph W.
2003-01-01
Background: Evidence suggests that biphasic waveforms are more effective than monophasic waveforms for defibrillation in out-of-hospital cardiac arrest (OHCA), yet their performance has only been compared in un-blinded studies. Methods and results: We compared the success of biphasic truncated
Yoshikawa, Jun
Biphasic nanoparticle mixtures composed of attractive and repulsive colloidal species enable the direct-write assembly of 3D structures with much finer features than those produced by pure colloidal gels. These mixtures rely on the use of comb polymer dispersants to render one particle population stable, while the other population is attractive. In this thesis, we systematically investigate the effects of comb polymer architecture and particle size ratio on the behavior of biphasic nanoparticle inks with the overarching aim of further advancing the direct-write assembly of 3D colloidal structures. We first investigated the effects of both pure polyelectrolytes, poly(acrylic acid) (PAA) and poly(methacrylic acid) (PMAA), and comb polymer dispersants composed of a PMAA backbone with methoxy-poly(ethylene oxide) (mPEO) teeth of varying molecular weights on the stability of barium titanate (BaTiO 3) suspensions. While each dispersant imparts stability to BaTiO 3 nanoparticles at low ionic strength (teeth (MWteeth = 2000) provides stability at higher ionic strengths over a broad range of particle sizes and counterion valencies. These results provide guidelines for tailoring the molecular architecture and functionality of comb polymer dispersants for optimal stabilization of the repulsive particle population within the biphasic inks. Next, particle size effects on the rheological properties of biphasic nanoparticle suspensions are studied. Shear elastic modulus, shear yield stress, and compressive yield stress are measured for mixtures of varying total volume fraction, attractive-to-repulsive volume fraction, and particle size ratio between attractive and repulsive species. Our observations indicate that the repulsive particles hinder the formation of the attractive gel network. The time required for shear elastic modulus to approach a steady-state value increases with the fraction of repulsive species. Furthermore, this behavior becomes more significant with increasing
Energy Technology Data Exchange (ETDEWEB)
Silva, E.F. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Gamino, M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Andrade, A.M.H. de [Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Vázquez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Correa, M.A. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Bohn, F., E-mail: felipebohn@fisica.ufrn.br [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil)
2017-02-01
We investigate the quasi-static magnetic, magnetotransport, and dynamic magnetic properties in ferromagnetic biphase films with distinct non-magnetic metallic spacer layers. We observe that the nature of the non-magnetic metallic spacer material does not have significant influence on the overall biphase magnetic behavior, and, consequently, on the magnetotransport and dynamic magnetic responses. We focus on the magnetoimpedance effect and verify that the films present asymmetric magnetoimpedance effect. Moreover, we explore the possibility of tuning the linear region of the magnetoimpedance curves around zero magnetic field by varying the probe current frequency in order to achieve higher sensitivity values. The invariance of the magnetic behavior and the asymmetric magnetoimpedance effect in ferromagnetic biphase films with distinct non-magnetic metallic spacers place them as promising candidates for probe element and open possibilities to the development of lower-cost high sensitivity linear magnetic field sensor devices.
Reilingh, Mikel L.; van Bergen, Christiaan J. A.; Gerards, Rogier M.; van Eekeren, Inge C.; de Haan, Rob J.; Sierevelt, Inger N.; Kerkhoffs, Gino M. M. J.; Krips, Rover; Meuffels, Duncan E.; van Dijk, C. N.; Blankevoort, Leendert
2016-01-01
Osteochondral defects (OCDs) of the talus usually affect athletic patients. The primary surgical treatment consists of arthroscopic debridement and microfracture. Various possibilities have been suggested to improve the recovery process after debridement and microfracture. A potential solution to
Anti-prelog reduction of prochiral carbonyl compounds by Oenococcus oeni in a biphasic system.
Hu, Jian; Xu, Yan
2006-07-01
An aqueous-organic biphasic system was established and used with whole cells of Oenococcus oeni to reduce 2-octanone to (R)-2-octanol. The conversion reached 99% when the Tris/borate buffer was increased from 50 mM to 300 mM in the aqueous phase. In addition, the conversion increased as the log P value of the organic solvent changed from 0.5 to 6.6. Under optimized conditions, the conversion of (R)-2-octanol reached 99% from 0.5 M 2-octanone with an optical purity of 99% e.e. The biphasic system allows the anti-Prelog reduction of aliphatic and aromatic ketones to furnish (R)-configurated alcohols in high optical purity as well.
Pudendal nerve stimulation and block by a wireless-controlled implantable stimulator in cats.
Yang, Guangning; Wang, Jicheng; Shen, Bing; Roppolo, James R; de Groat, William C; Tai, Changfeng
2014-07-01
The study aims to determine the functionality of a wireless-controlled implantable stimulator designed for stimulation and block of the pudendal nerve. In five cats under α-chloralose anesthesia, the stimulator was implanted underneath the skin on the left side in the lower back along the sacral spine. Two tripolar cuff electrodes were implanted bilaterally on the pudendal nerves in addition to one bipolar cuff electrode that was implanted on the left side central to the tripolar cuff electrode. The stimulator provided high-frequency (5-20 kHz) biphasic stimulation waveforms to the two tripolar electrodes and low-frequency (1-100 Hz) rectangular pulses to the bipolar electrode. Bladder and urethral pressures were measured to determine the effects of pudendal nerve stimulation (PNS) or block. The maximal (70-100 cmH2O) urethral pressure generated by 20-Hz PNS applied via the bipolar electrode was completely eliminated by the pudendal nerve block induced by the high-frequency stimulation (6-15 kHz, 6-10 V) applied via the two tripolar electrodes. In a partially filled bladder, 20-30 Hz PNS (2-8 V, 0.2 ms) but not 5 Hz stimulation applied via the bipolar electrode elicited a large sustained bladder contraction (45.9 ± 13.4 to 52.0 ± 22 cmH2O). During cystometry, the 5 Hz PNS significantly (p < 0.05) increased bladder capacity to 176.5 ± 27.1% of control capacity. The wireless-controlled implantable stimulator successfully generated the required waveforms for stimulation and block of pudendal nerve, which will be useful for restoring bladder functions after spinal cord injury. © 2013 International Neuromodulation Society.
Díaz Lantada, Andrés; Alarcón Iniesta, Hernán; García-Ruíz, Josefa Predestinación
2016-02-01
Articular repair is a relevant and challenging area for the emerging fields of tissue engineering and biofabrication. The need of significant gradients of properties, for the promotion of osteochondral repair, has led to the development of several families of composite biomaterials and scaffolds, using different effective approaches, although a perfect solution has not yet been found. In this study we present the design, modeling, rapid manufacturing and in vitro testing of a composite scaffold aimed at osteochondral repair. The presented composite scaffold stands out for having a functional gradient of density and stiffness in the bony phase, obtained in titanium by means of computer-aided design combined with additive manufacture using selective laser sintering. The chondral phase is obtained by sugar leaching, using a PDMS matrix and sugar as porogen, and is joined to the bony phase during the polymerization of PDMS, therefore avoiding the use of supporting adhesives or additional intermediate layers. The mechanical performance of the construct is biomimetic and the stiffness values of the bony and chondral phases can be tuned to the desired applications, by means of controlled modifications of different parameters. A human mesenchymal stem cell (h-MSC) conditioned medium (CM) is used for improving scaffold response. Cell culture results provide relevant information regarding the viability of the composite scaffolds used. Copyright © 2015 Elsevier B.V. All rights reserved.
Chang, N-J; Lam, C-F; Lin, C-C; Chen, W-L; Li, C-F; Lin, Y-T; Yeh, M-L
2013-10-01
Repairing articular cartilage is clinically challenging. We investigated a simple, effective and clinically feasible cell-based therapeutic approach using a poly(lactide-co-glycolide) (PLGA) scaffold seeded with autologous endothelial progenitor cells (EPC) to repair a full-thickness osteochondral defect in rabbits using a one-step surgery. EPC obtained by purifying a small amount of peripheral blood from rabbits were seeded into a highly porous, biocompatible PLGA scaffold, namely, EPC-PLGA, and implanted into the osteochondral defect in the medial femoral condyle. Twenty two rabbits were randomized into one of three groups: the empty defect group (ED), the PLGA-only group or the EPC-PLGA group. The defect sites were evaluated 4 and 12 weeks after implantation. At the end of testing, only the EPC-PLGA group showed the development of new cartilage tissue with a smooth, transparent and integrated articular surface. Moreover, histological analysis showed obvious differences in cartilage regeneration. At week 4, the EPC-PLGA group showed considerably higher TGF-β2 and TGF-β3 expression, a greater amount of synthesized glycosaminoglycan (GAG) content, and a higher degree of osteochondral angiogenesis in repaired tissues. At week 12, the EPC-PLGA group showed enhanced hyaline cartilage regeneration with a normal columnar chondrocyte arrangement, higher SOX9 expression, and greater GAG and collagen type II (COLII) content. Moreover, the EPC-PLGA group showed organized osteochondral integration, the formation of vessel-rich tubercular bone and significantly higher bone volume per tissue volume and trabecular thickness (Tb.Th). The present EPC-PLGA cell delivery system generates a suitable in situ microenvironment for osteochondral regeneration without the supplement of exogenous growth factors. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Guzmán-Morales, J; Lafantaisie-Favreau, C-H; Chen, G; Hoemann, C D
2014-02-01
Little is known of how to routinely elicit hyaline cartilage repair tissue in middle-aged patients. We tested the hypothesis that in skeletally aged rabbit knees, microdrill holes can be stimulated to remodel the bone plate and induce a more integrated, voluminous and hyaline cartilage repair tissue when treated by subchondral chitosan/blood implants. New Zealand White rabbits (13 or 32 months old, N = 7) received two 1.5 mm diameter, 2 mm depth drill holes in each knee, either left to bleed as surgical controls or press-fit with a 10 kDa (distal hole: 10K) or 40 kDa (proximal hole: 40K) chitosan/blood implant with fluorescent chitosan tracer. Post-operative knee effusion was documented. Repair tissues at day 0 (N = 1) and day 70 post-surgery (N = 6) were analyzed by micro-computed tomography, and by histological scoring and histomorphometry (SafO, Col-2, and Col-1) at day 70. All chitosan implants were completely cleared after 70 days, without increasing transient post-operative knee effusion compared to controls. Proximal control holes had worse osteochondral repair than distal holes. Both implant formulations induced bone remodeling and improved lateral integration of the bone plate at the hole edge. The 40K implant inhibited further bone repair inside 50% of the proximal holes, while the 10K implant specifically induced a "wound bloom" reaction, characterized by decreased bone plate density in a limited zone beyond the initial hole edge, and increased woven bone (WB) plate repair inside the initial hole (P = 0.016), which was accompanied by a more voluminous and hyaline cartilage repair (P holes with a biodegradable subchondral implant that elicits bone plate resorption followed by anabolic WB repair within a 70-day repair period. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Cugat, Ramón; Alentorn-Geli, Eduard; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Cuscó, Xavier; Seijas, Roberto; Barastegui, David; Navarro, Jordi; Laiz, Patricia; García-Balletbó, Montserrat
2017-01-01
Knee cartilage or osteochondral lesions are common and challenging injuries. To date, most symptomatic lesions warrant surgical treatment. We present two cases of patients with knee osteochondral defects treated with a one-step surgical procedure consisting of an autologous-based matrix composed of healthy hyaline cartilage chips, mixed plasma poor-rich in platelets clot, and plasma rich in growth factors (PRGF). Both patients returned to playing soccer at the preinjury activity level and demonstrated excellent defect filling in both magnetic resonance imaging and second-look arthroscopy (in one of them). The use of a clot of autologous plasma poor in platelets with healthy hyaline cartilage chips and intra-articular injection of plasma rich in platelets is an effective, easy, and cheap option to treat knee cartilage injuries in young and athletic patients.
Directory of Open Access Journals (Sweden)
Ramón Cugat
2017-01-01
Full Text Available Knee cartilage or osteochondral lesions are common and challenging injuries. To date, most symptomatic lesions warrant surgical treatment. We present two cases of patients with knee osteochondral defects treated with a one-step surgical procedure consisting of an autologous-based matrix composed of healthy hyaline cartilage chips, mixed plasma poor-rich in platelets clot, and plasma rich in growth factors (PRGF. Both patients returned to playing soccer at the preinjury activity level and demonstrated excellent defect filling in both magnetic resonance imaging and second-look arthroscopy (in one of them. The use of a clot of autologous plasma poor in platelets with healthy hyaline cartilage chips and intra-articular injection of plasma rich in platelets is an effective, easy, and cheap option to treat knee cartilage injuries in young and athletic patients.
Czech Academy of Sciences Publication Activity Database
El Kammouni, R.; Vázquez, M.; Lezama, L.; Kurlyandskaya, G.; Kraus, Luděk
2014-01-01
Roč. 368, Nov (2014), 126-132 ISSN 0304-8853 Institutional support: RVO:68378271 Keywords : magnetic microwire * ferromagnetic resonance * microwave absorption * biphase magnetic system Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.970, year: 2014
Occurrence of amylose-lipid complexes in teff and maize starch biphasic pastes
CSIR Research Space (South Africa)
Wokadala, OC
2012-09-01
Full Text Available The occurrence of amylose–lipid complexes was determined in maize and teff starch biphasic pastes i.e. peak viscosity pastes at short and prolonged pasting times. Maize and teff starches were pasted for 11.5 and 130 min with or without added stearic...
Acute exercise induces biphasic increase in respiratory mRNA in skeletal muscle
International Nuclear Information System (INIS)
Ikeda, Shin-ichi; Kizaki, Takako; Haga, Shukoh; Ohno, Hideki; Takemasa, Tohru
2008-01-01
Peroxisome proliferator-activated receptor γ coactivator-1α (PGC-1α) promotes the expression of oxidative enzymes in skeletal muscle. We hypothesized that activation of the p38 MAPK (mitogen-activated protein kinase) in response to exercise was associated with exercise-induced PGC-1α and respiratory enzymes expression and aimed to demonstrate this under the physiological level. We subjected mice to a single bout of treadmill running and found that the exercise induced a biphasic increase in the expression of respiratory enzymes mRNA. The second phase of the increase was accompanied by an increase in PGC-1α protein, but the other was not. Administration of SB203580 (SB), an inhibitor of p38 MAPK, suppressed the increase in PGC-1α expression and respiratory enzymes mRNA in both phases. These data suggest that p38 MAPK is associated with the exercise-induced expression of PGC-1α and biphasic increase in respiratory enzyme mRNAs in mouse skeletal muscle under physiological conditions
Directory of Open Access Journals (Sweden)
Cezar Teruyuki Kawano
2012-10-01
Full Text Available OBJECTIVE: To evaluate the clinical and functional results of autologous trapezoidal plug single-block grafts fixed with absorbable chondral darts in patients with osteochondral knee lesions of varying sizes. METHODS: Twenty-five patients underwent surgery from February 2000 to June 2008. Seventy-two percent of the patients were male, and the mean age was 29 years. RESULTS: The right side (56% and the medial condyle (92% were most affected. The lesions had an average area of 5.28 cm², and the mean follow-up was 59 months. All of the variables other than instability showed significant improvements (p<0.05, as shown by the increase in the mean Lysholm score from 55 points preoperatively to 92 points (p<0.001 postoperatively. There was no loosening or collapse of the osteochondral graft. All of the patients had patellofemoral crepitation and pain for an average of six months. CONCLUSION: Autologous trapezoidal plug single-block grafts are a therapeutic option for defects of varying sizes and provide good clinical results and low morbidity at the donor site in the medium term.
Directory of Open Access Journals (Sweden)
Subramoniam Sundaram
2014-01-01
Full Text Available One of the main objectives of periodontal therapy is to prolong the lifespan of dentition as there is no ideal substitute for natural dentition even in the era of dental implants. Treatment of teeth with advanced periodontal disease with hopeless prognosis is always extraction. However in this case report, we discuss a novel regenerative strategy using a combination of platelet rich plasma and bi-phasic tri calcium phosphate for a lower central incisor that was considered for extraction. Clinical and radiographic examination during the six-year follow-up postoperatively revealed stable periodontal health in the lower right central incisor. The surgical re-entry done in the sixth year postoperatively revealed good periradicular healing and alloplastic bone graft incorporation within the host bone.
Directory of Open Access Journals (Sweden)
Colin eHorne
2016-02-01
Full Text Available We present a phenomenological model of electrically stimulated auditory nerve fibers (ANFs. The model reproduces the probabilistic and temporal properties of the ANF response to both monophasic and biphasic stimuli, in isolation. The main contribution of the model lies in its ability to reproduce statistics of the ANF response (mean latency, jitter, and firing probability under both monophasic and cathodic-anodic biphasic stimulation, without changing the model’s parameters. The response statistics of the model depend on stimulus level and duration of the stimulating pulse, reproducing trends observed in the ANF. In the case of biphasic stimulation, the model reproduces the effects of pseudomonophasic pulse shapes and also the dependence on the interphase gap (IPG of the stimulus pulse, an effect that is quantitatively reproduced. The model is fitted to ANF data using a procedure that uniquely determines each model parameter. It is thus possible to rapidly parameterize a large population of neurons to reproduce a given set of response statistic distributions.Our work extends the stochastic leaky integrate and fire (SLIF neuron, a well-studied phenomenological model of the electrically stimulated neuron. We extend the SLIF neuron so as to produce a realistic latency distribution by delaying the moment of spiking. During this delay, spiking may be abolished by anodic current. By this means, the probability of the model neuron responding to a stimulus is reduced when a trailing phase of opposite polarity is introduced. By introducing a minimum wait period that must elapse before a spike may be emitted, the model is able to reproduce the differences in the threshold level observed in the ANF for monophasic and biphasic stimuli. Thus, the ANF response to a large variety of pulse shapes are reproduced correctly by this model.
Potter, Kelsey A.; Buck, Amy C.; Self, Wade K.; Capadona, Jeffrey R.
2012-08-01
An estimated 25 million people in the US alone rely on implanted medical devices, ˜2.5 million implanted within the nervous system. Even though many devices perform adequately for years, the host response to medical devices often severely limits tissue integration and long-term performance. This host response is believed to be particularly limiting in the case of intracortical microelectrodes, where it has been shown that glial cell encapsulation and localized neuronal cell loss accompany intracortical microelectrode implantation. Since neuronal ensembles must be within ˜50 µm of the electrode to obtain neuronal spikes and local field potentials, developing a better understanding of the molecular and cellular environment at the device-tissue interface has been the subject of significant research. Unfortunately, immunohistochemical studies of scar maturation in correlation to device function have been inconclusive. Therefore, here we present a detailed quantitative study of the cellular events and the stability of the blood-brain barrier (BBB) following intracortical microelectrode implantation and cortical stab injury in a chronic survival model. We found two distinctly inverse multiphasic profiles for neuronal survival in device-implanted tissue compared to stab-injured animals. For chronically implanted animals, we observed a biphasic paradigm between blood-derived/trauma-induced and CNS-derived inflammatory markers driving neurodegeneration at the interface. In contrast, stab injured animals demonstrated a CNS-mediated neurodegenerative environment. Collectively these data provide valuable insight to the possibility of multiple roles of chronic neuroinflammatory events on BBB disruption and localized neurodegeneration, while also suggesting the importance to consider multiphasic neuroinflammatory kinetics in the design of therapeutic strategies for stabilizing neural interfaces.
Directory of Open Access Journals (Sweden)
Hirokazu Kawasaki
2005-01-01
Conclusions: The present study provides a simple model of allergic biphasic nasal obstruction in BN rats, and also suggests that the PDE4 inhibitor may alleviate nasal obstruction in patients with allergic rhinitis.
Directory of Open Access Journals (Sweden)
Ajay Kumar
2016-01-01
Full Text Available Type 2 diabetes (T2D represents an escalating burden worldwide, particularly in China and India. Compared with Caucasians, Asian people with diabetes have lower body mass index, increased visceral adiposity, and postprandial glucose (PPG/insulin resistance. Since postprandial hyperglycemia contributes significantly to total glycemic burden and is associated with heightened cardiovascular risk, targeting PPG early in T2D is paramount. Premixed insulin regimens are widely used in Asia due to their convenience and effectiveness. Data from randomized controlled trials and observational studies comparing efficacy and safety of biphasic insulin aspart 30 (BIAsp 30 with biphasic insulin lispro mix (LM 25/50 and versus other insulin therapies or oral antidiabetic drugs (OADs in T2D demonstrated that BIAsp 30 and LM 25/50 were associated with similar or greater improvements in glycemic control versus comparator regimens, such as basal–bolus insulin, in insulin-naÏve, and prior insulin users. Studies directly comparing BIAsp 30 and LM 25 provided conflicting glycemic control results. Safety data generally showed increased hypoglycemia and weight gain with premixed insulins versus basal–bolus insulin or OADs. However, large observational trials documented improvements in glycated hemoglobin, PPG, and hypoglycemia with BIAsp 30 in multi-ethnic patient populations. In summary, this literature review demonstrates that premixed insulin regimens are an appropriate and effective treatment choice in T2D.
Biphasic growth of orbital volume in Chinese children.
Wei, Nan; Bi, Hua; Zhang, Bin; Li, Xue; Sun, Fengyuan; Qian, Xuehan
2017-09-01
The aim of this study was to map out the developmental curve of the orbital volume of Chinese children aged 1-15 years. CT scanning was performed on 109 children and the orbital volume, interlateral orbital rim distance (IORD), and extent of exophthalmos were measured on the CT images and plotted against age. The development of the orbit structure followed a biphasic pattern. The first growth phase was before 3 years and the second growth phase was between 7 years and 12 years of age. The growth speed in the first phase was about 3 times that of the second one (first vs second phase: 2.28 cm 3 /year vs 0.67 cm 3 /year for orbital volume, 5.01 mm/year vs 1.57 mm/year for IORD, 1.29 mm/year vs 0.42 mm/year for the exophthalmos). During development, there was no significant difference between the left and right orbits. There was no significant difference between boys and girls before 12 years of age. However, after 12 years of age, boys had significantly larger orbital volumes (22.16±2.28 cm 3 /year vs 18.57±1.16 cm 3 /year, pChinese children, the development of orbital volume follows a biphasic pattern and a sex difference becomes significant after the age of 12 years. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Murray, P R
1991-01-01
Although the detection of fungemia has been improved by the use of vented or biphasic blood culture bottles, the best recovery and earliest detection have been reported in the Isolator lysis-centrifugation system. It was recently demonstrated that improved detection of both bacteria and fungi was accomplished by mechanically agitating blood culture bottles for the first 24 h of incubation. In this study the detection of fungemia by use of the Isolator system was compared with that of an agitated biphasic system. A total of 182 fungi were isolated from blood specimens inoculated into both culture systems. No difference in the overall recovery of fungi or individual species of yeasts was observed between the two systems. However, all seven isolates of Histoplasma capsulatum were recovered in the Isolator system only. The time required to detect fungemia with each of the two systems was also compared. No statistically significant difference was observed. From the data collected during this 18-month study, it can be concluded that the overall recovery and time of detection of yeasts are equivalent in the lysis-centrifugation system and the agitated biphasic blood culture system. The lysis-centrifugation system is still superior for the detection of filamentous fungi such as H. capsulatum. PMID:1993772
Energy Technology Data Exchange (ETDEWEB)
Herber, S.; Pitton, M.B.; Kalden, P.; Thelen, M.; Kreitner, K.F. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Radiologie; Runkel, M. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Unfallchirurgie
2003-02-01
Purpose: To evaluate the spectrum of findings in indirect MR-arthrography following autologous osteochondral transplantation. Patients and Methods: 10 patients with autogenous osteochondral homografts underwent indirect MR-arthrography at three, 6 and 12 months postoperatively. The MR protocol at 1.5T comprised unenhanced imagings with PD- and T{sub 2}-weighted TSE-sequences with and without fat-suppression as well as T{sub 1}-weighted fat-suppressed SE-sequences before and after iv. contrast administration and after active joint exercise. Image analysis was done by two radiologists in conference and comprised the evaluation of signal intensity (SI) and integrity of the osseous plug and the cartilage surface, as well as the presence of joint effusion or bone marrow edema. Results: At three months, all cases demonstrated a significant bone marrow edema at the recipient and donor site that corresponded to a significant enhancement after iv. contrast administration. The interface between the transplant and the normal bone showed an increased SI at three and 6 months in T{sub 2}-weighted images as well as in indirect MR-arthrography. The marrow signal normalized in most cases after 6 to 12 months, indicating vitality and healing of the transplanted osteochondral graft. The SI of the interface decreased in the same period, demonstrating the stability of the homograft at the recipient site. The osteochondral plugs were well-seated in 9/10 cases. Indirect MR-arthrography was superior to unenhanced imaging in the assessment of the cartilage surface. Cartilage coverage was complete in every case. The transplanted hyaline cartilage as well as the original cartilage showed a significant increase of the SI in indirect MR-arthrography, that did not change in follow up studies. There were no pathological alterations of signal and thickness alterations of the transplanted cartilage in follow up investigations. Conclusion: Indirect MR-arthrography is a useful diagnostic tool
Biphasic single-reactor process for dehydration of xylose and hydrogenation of produced furfural
Ordomskiy, V.; Schouten, J.C.; Schaaf, van der J.; Nijhuis, T.A.
2013-01-01
The processes of xylose dehydration and the consecutive furfural hydrogenation have been combined in a single biphasic reactor. The dehydration was studied over Amberlyst-15 and the hydrogenation over a hydrophobic Ru/C catalyst. 1-Butanol, 2-methyltetrahydrofuran and cyclohexane were used as
Multi-scale osteointegration and neovascularization of biphasic calcium phosphate bone scaffolds
Lan, Sheeny K.
Bone grafts are utilized clinically to guide tissue regeneration. Autologous bone and allogeneic bone are the current clinical standards. However, there are significant limitations to their use. To address the need for alternatives to autograft and allograft, researchers have worked to develop synthetic grafts, also referred to as scaffolds. Despite extensive efforts in this area, a gap persists between basic research and clinical application. In particular, solutions for repairing critical size and/or load-bearing defects are lacking. The aim of this thesis work was to address two critical barriers preventing design of successful tissue engineering constructs for bone regeneration within critical size and/or load-bearing defects. Those barriers are insufficient osteointegration and slow neovascularization. In this work, the effects of scaffold microporosity, recombinant human bone morphogenetic protein-2 delivery and endothelial colony forming cell vasculogenesis were evaluated in the context of bone formation in vivo. This was accomplished to better understand the role of these factors in bone regeneration, which may translate to improvements in tissue engineering construct design. Biphasic calcium phosphate (BCP) scaffolds with controlled macro- and microporosity were implanted in porcine mandibular defects. Evaluation of the BCP scaffolds after in vivo implantation showed, for the first time, osteocytes embedded in bone within scaffold micropores (macro and micro length scales, leaving no "dead space" or discontinuities of bone in the defect site. The scaffold forms a living composite upon integration with regenerating bone and this has significant implications with regard to improved scaffold mechanical properties. The presence of osteocytes within scaffold micropores is an indication of scaffold osteoinductivity because a chemotactic factor must be present to induce cell migration into pores on the order of the cell diameter. It is likely that the scaffold
Kim, Jeong-Woo; Shin, Yong Cheol; Lee, Jin-Ju; Bae, Eun-Bin; Jeon, Young-Chan; Jeong, Chang-Mo; Yun, Mi-Jung; Lee, So-Hyoun; Han, Dong-Wook; Huh, Jung-Bo
2017-08-08
This study was conducted to evaluate the effect of biphasic calcium phosphate (BCP) coated with reduced graphene oxide (rGO) as bone graft materials on bone regeneration. The rGO-coated BCP bone graft material was fabricatied by mixing rGO and BCP at various concentrations. The surface charge of rGO-coated BCP was measured to be -14.43 mV, which formed a static electrostatic interaction. Cell viabilities were significantly diminished at higher concentrations of ≥100 μg/mL. The calvarial defects of 48 rats were implanted rGO-coated BCPs at a weight ratio of 2:1000 (rGO2), 4:1000 (rGO4), and 10:1000 (rGO10), repectively. BCP was used as a control group. The micro-CT and histological analysis were performed to evaluate new bone formation at 2 and 8 weeks after surgery. The results showed that the new bone volume (mm³) was significantly higher in the experimental groups than in the control group. Histological analysis showed that new bone areas (%) were significantly higher in the rGO2 and rGO10 than in the control, and significantly higher in rGO4 than in the rGO2 and rGO10. Conclusively, the rGO-coated BCP was found to be effective on osteogenesis and the concentration of the composite was an important factor.
Pascual-Garrido, Cecilia; Daley, Erika; Verma, Nikhil N; Cole, Brian J
2017-02-01
To compare the results of focal metallic resurfacing with biologic procedures in patients more than 35 years of age with isolated, full thickness defects of the femoral condyle. A total of 61 patients met the selection criteria resulting in 30 patients treated with biological procedures, including debridement, microfracture, osteochondral autograft transplantation, osteochondral allograft, and autologous chondrocyte implantation (BIO group), and 32 patients treated with focal metallic resurfacing (CAP group). The BIO and CAP groups were matched according to treatment location, defect grade and size, and age profile. Outcomes included Western Ontario and McMaster Osteoarthritis Index (WOMAC), Short Form-12, and satisfaction. The primary combination endpoint was determined as a 20% improvement (minimum clinically important difference-20) on WOMAC pain and function at 2 years and no additional index lesion-related surgical intervention. Safety and effectiveness were also reported. Thirty patients in the BIO group (mean age of 44.6, range 35-64) had an average follow-up of 2.6 years and 32 patients in the CAP group (mean age 47.9, range 37-68) were followed for 2.0 years. Fifty-three percent in the BIO group and 75% in the CAP group achieved success per the endpoint definition. The mean total WOMAC score improved significantly for both groups (BIO: 57-78; P metal resurfacing procedures for the treatment of isolated focal chondral lesions of the femoral condyle in the knee. Focal metallic resurfacing results in similar clinical outcomes and provides excellent success rates at short-term follow-up. Level III comparative study. Copyright © 2016. Published by Elsevier Inc.
International Nuclear Information System (INIS)
Jans, Lennart B.O.; Ditchfield, Michael; Anna, Gomez; Jaremko, Jacob L.; Verstraete, Koenraad L.
2012-01-01
Purpose: Osteochondritis dissecans (OCD) of the elbow is an uncommon cause of elbow pain in adolescents and occurs at different locations in the elbow joint. Early diagnosis and treatment may prevent surgery. The aim of the study is to describe the MR imaging features of OCD at initial imaging, and to correlate these findings with surgical findings of stability and instability with arthroscopic findings as the reference standard. Methods: Patients were identified through a keyword search of the radiology information system from 2000 to 2009. Twenty-five patients (26 elbows) with OCD of the elbow were identified (age 10.4–18 years, mean age 14 years). MR studies were retrospectively reviewed by two radiologists in consensus to define MR imaging findings and to determine the presence of previously described MR imaging criteria for OCD instability (i.e., high T2 signal rim, surrounding cysts, high T2 signal fracture line, fluid-filled osteochondral defect). Sensitivity of the individual and combined criteria was calculated. Results: OCD occurred in the capitellum in 24 patients (92%), in the trochlea in 2 patients (8%) and radial head in 1 patient (4%). Loose bodies were identified in 11 (42%) patients. Eighteen patients demonstrated MRI findings in keeping with unstable lesions. In all 11 patients who had surgery the surgical findings of instability correlated with the MRI findings. When combined, the MR criteria were 100% sensitive for instability of OCD lesions of the elbow. Conclusion: The vast majority of OCD of the elbow occurs in the capitellum. When used together, the MR criteria for instability were 100% sensitive for evaluation OCD lesions of the elbow.
Energy Technology Data Exchange (ETDEWEB)
Streitparth, F. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany)], E-mail: florian.streitparth@charite.de; Schoettle, P.; Schell, H. [Center for Musculoskeletal Surgery, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Lehmkuhl, L.; Madej, T.; Wieners, G. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Duda, G.N. [Center for Musculoskeletal Surgery, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany); Schroeder, R.J. [Klinik fuer Strahlenheilkunde, Charite, Campus Virchow-Klinikum, Humboldt-University, Berlin (Germany)
2009-04-15
Objective: To analyze the spectrum of findings in indirect MR-arthrography following osteochondral autograft transfer system (OATS) and crushed bone graft using a magnetic resonance imaging (MRI) scoring and grading system in relation to histology as the standard of reference. Materials and methods: Iatrogenic lesions were set at ovine condylar facets (n = 6/group), treated with OATS or crushed bone graft. 1.5 T MRI was performed 6 months after surgery using PD-weighted (w fat saturated (fs) fast spin echo (FSE), T1-w 2D, and 3D fs gradient echo (GE) sequences 30 min. after i.v. Gd-DTPA administration and passive joint exercise. The repair tissue was evaluated by two independent radiologists. The MR findings were compared to histology. Results: In all cases, MRI and histologic grading correlated well and showed significant superior repair in OATS at 6 months (p < 0.05), reproducing the original articular contour and a good subchondral restoration. FsT1-w3DGE proved most appropriate identifying characteristic post-operative findings: the OATS group demonstrated bone marrow edema at the donor site and the graft/host interface showed significant enhancement in indirect MR-arthrography, indicating fibrocartilage. After crushed bone graft, we found an irregular structure and significant contrast uptake, consistent with remnants of bone grafts surrounded by inflammatory tissue. Conclusion: Indirect MR-arthrography is an accurate, non-invasive monitoring tool following OATS and crushed bone graft as the MRI scoring and grading system allows a reliable evaluation of normal and pathological osteochondral repair with a high histologic correlation.
Cadossi, Matteo; Buda, Roberto Emanuele; Ramponi, Laura; Sambri, Andrea; Natali, Simone; Giannini, Sandro
2014-10-01
Osteochondral lesions of the talus (OLT) frequently occur after ankle sprains in young patients participating in sports activities. These injuries may lead to chronic pain, joint swelling, and finally osteoarthritis, therefore, surgical repair is frequently needed. A collagen scaffold seeded with bone marrow-derived cells (BMDCs) harvested from patient's iliac crest and implanted into the OLT through a single arthroscopic procedure has been recently proposed as an effective treatment option. Nevertheless, BMDCs, embedded in an inflammatory environment, tend to differentiate toward a fibroblast phenotype with a consequential loss of mechanical characteristics. Biophysical stimulation with pulsed electromagnetic fields (PEMFs) has been shown to promote anabolic chondrocyte activity, stimulate proteoglycan synthesis, and reduce the release of the most relevant pro-inflammatory cytokines. The aim of this randomized controlled trial was to evaluate the effects of PEMFs on clinical outcome in patients who underwent BMDCs transplantation for OLT. Thirty patients affected by grade III and IV Outerbridge OLT underwent BMDCs transplantation. After surgery, patients were randomly assigned to either experimental group (PEMFs 4 hours per day for 60 days starting within 3 days after operation) or control group. Clinical outcome was evaluated with (American Orthopaedic Foot and Ankle Society) AOFAS score, Visual Analog Scale (VAS), and Short Form-36 (SF-36). Significantly higher AOFAS score was recorded in the experimental group both at 6 or 12 months follow-up. At 60 days and 6 and 12 months follow-up, significant lower pain was observed in the experimental group. No significant difference was found in SF-36 between groups. A superior clinical outcome was found in the experimental group with more than 10 points higher AOFAS score at final follow-up. Biophysical stimulation started soon after surgery aided patient recovery leading to pain control and a better clinical outcome
Hsieh, Yi-Ho; Shen, Bo-Yuan; Wang, Yao-Horng; Lin, Bojain; Lee, Hung-Maan; Hsieh, Ming-Fa
2018-04-09
Articular cartilage is a structure lack of vascular distribution. Once the cartilage is injured or diseased, it is unable to regenerate by itself. Surgical treatments do not effectively heal defects in articular cartilage. Tissue engineering is the most potential solution to this problem. In this study, methoxy poly(ethylene glycol)-block-poly(ε-caprolactone) (mPEG-PCL) and hydroxyapatite at a weight ratio of 2:1 were mixed via fused deposition modeling (FDM) layer by layer to form a solid scaffold. The scaffolds were further infiltrated with glycidyl methacrylate hyaluronic acid loading with 10 ng/mL of Transforming Growth Factor-β1 and photo cross-linked on top of the scaffolds. An in vivo test was performed on the knees of Lanyu miniature pigs for a period of 12 months. The healing process of the osteochondral defects was followed by computer tomography (CT). The defect was fully covered with regenerated tissues in the control pig, while different tissues were grown in the defect of knee of the experimental pig. In the gross anatomy of the cross section, the scaffold remained in the subchondral location, while surface cartilage was regenerated. The cross section of the knees of both the control and experimental pigs were subjected to hematoxylin and eosin staining. The cartilage of the knee in the experimental pig was partially matured, e.g., few chondrocyte cells were enclosed in the lacunae. In the knee of the control pig, the defect was fully grown with fibrocartilage. In another in vivo experiment in a rabbit and a pig, the composite of the TGF-β1-loaded hydrogel and scaffolds was found to regenerate hyaline cartilage. However, scaffolds that remain in the subchondral lesion potentially delay the healing process. Therefore, the structural design of the scaffold should be reconsidered to match the regeneration process of both cartilage and subchondral bone.
Directory of Open Access Journals (Sweden)
Yi-Ho Hsieh
2018-04-01
Full Text Available Articular cartilage is a structure lack of vascular distribution. Once the cartilage is injured or diseased, it is unable to regenerate by itself. Surgical treatments do not effectively heal defects in articular cartilage. Tissue engineering is the most potential solution to this problem. In this study, methoxy poly(ethylene glycol-block-poly(ε-caprolactone (mPEG-PCL and hydroxyapatite at a weight ratio of 2:1 were mixed via fused deposition modeling (FDM layer by layer to form a solid scaffold. The scaffolds were further infiltrated with glycidyl methacrylate hyaluronic acid loading with 10 ng/mL of Transforming Growth Factor-β1 and photo cross-linked on top of the scaffolds. An in vivo test was performed on the knees of Lanyu miniature pigs for a period of 12 months. The healing process of the osteochondral defects was followed by computer tomography (CT. The defect was fully covered with regenerated tissues in the control pig, while different tissues were grown in the defect of knee of the experimental pig. In the gross anatomy of the cross section, the scaffold remained in the subchondral location, while surface cartilage was regenerated. The cross section of the knees of both the control and experimental pigs were subjected to hematoxylin and eosin staining. The cartilage of the knee in the experimental pig was partially matured, e.g., few chondrocyte cells were enclosed in the lacunae. In the knee of the control pig, the defect was fully grown with fibrocartilage. In another in vivo experiment in a rabbit and a pig, the composite of the TGF-β1-loaded hydrogel and scaffolds was found to regenerate hyaline cartilage. However, scaffolds that remain in the subchondral lesion potentially delay the healing process. Therefore, the structural design of the scaffold should be reconsidered to match the regeneration process of both cartilage and subchondral bone.
Directory of Open Access Journals (Sweden)
Charles Oluwaseun ADETUNJI
2017-09-01
Full Text Available Formulation of effective and environmental friendly bioherbicides depends on the type of fermentation medium used for the production of phytotoxic metabolites. The effect of biomass, colony forming unit and the phytotoxic metabolite produced from the biphasic fermentation was carried out, while the phytotoxic metabolite was tested in vivo and in-vitro on Echinochola crus-galli and dicotyledonous Chromolaena odorata. The mutant strain of Lasiodiplodia pseudotheobromae C1136 (Lp90 produced the highest amount of conidia and the largest necrotic area on the two tested weeds when compared to its wild strain in the different biphasic media combinations. The study revealed that the biphasic system containing PDB + rice produced the highest bioherbicidal activities. Therefore, the phytotoxic metabolites from strain C1136 are suggested for large scale production of bioherbicides for the management of weeds in conventional farming to improve yield and enhance food security.
International Nuclear Information System (INIS)
Oufroukhi, Y.; Biyi, A.; Doudouh, A.
2009-01-01
Osteo-chondritis, or Legg-Calve-Perthes disease (L.C.P.), is a necrosis of the proximal femoral epiphysis. This vascular accident entails on the complex phenomenon of growth of the child's hip and can result in deformations or even a strict destruction of the proximal femoral epiphysis. The aim of this article is to show the interest of the bone scintigraphy (B.S.) in precocious diagnosis and follow-up of L.C.P. disease. In this aim, we introduced a clinical case of L.C.P. disease where B.S. allowed a precocious diagnosis and a stringent monitoring. Discussion of case includes a systematic review of literature. (authors)
Species dependent radiotracer study of Cr(VI) and Cr(III) using an aqueous biphasic system
Energy Technology Data Exchange (ETDEWEB)
Roy, K.; Lahiri, S. [Chemical Sciences Div., Saha Inst. of Nuclear Physics, Kolkata (India)
2008-07-01
The speciation study of Cr(III) and Cr(VI) was carried out using a polyethylene glycol (PEG) based aqueous biphasic extraction system (ABS). Neutron activated Cr(III) and Cr(VI) salts were assayed in a HPGe detector before and after employing aqueous biphasic extraction. Different salts of various salting out abilities were taken as the salt rich phase. The best condition for extraction of Cr(VI) and the maximum differential attitude of ABS to Cr(VI) and Cr(III) was observed when 2 M Na{sub 2}SO{sub 4} and PEG 4000 (50% w/w) solutions were used. Cr(III) can also be extracted by the PEG with prior complexation with diphenylthiocarbazone (dithizone). The chromium dithizonate complex is quantitatively extracted by the PEG rich phase. (orig.)
Dennewald, Danielle; Hortsch, Ralf; Weuster-Botz, Dirk
2012-01-01
As clear structure-activity relationships are still rare for ionic liquids, preliminary experiments are necessary for the process development of biphasic whole-cell processes involving these solvents. To reduce the time investment and the material costs, the process development of such biphasic reaction systems would profit from a small-scale high-throughput platform. Exemplarily, the reduction of 2-octanone to (R)-2-octanol by a recombinant Escherichia coli in a biphasic ionic liquid/water system was studied in a miniaturized stirred-tank bioreactor system allowing the parallel operation of up to 48 reactors at the mL-scale. The results were compared to those obtained in a 20-fold larger stirred-tank reactor. The maximum local energy dissipation was evaluated at the larger scale and compared to the data available for the small-scale reactors, to verify if similar mass transfer could be obtained at both scales. Thereafter, the reaction kinetics and final conversions reached in different reactions setups were analysed. The results were in good agreement between both scales for varying ionic liquids and for ionic liquid volume fractions up to 40%. The parallel bioreactor system can thus be used for the process development of the majority of biphasic reaction systems involving ionic liquids, reducing the time and resource investment during the process development of this type of applications. Copyright © 2011. Published by Elsevier B.V.
Aqueous biphasic extraction of uranium and thorium from contaminated soils. Final report
International Nuclear Information System (INIS)
Chaiko, D.J.; Gartelmann, J.; Henriksen, J.L.; Krause, T.R.; Deepak; Vojta, Y.; Thuillet, E.; Mertz, C.J.
1995-07-01
The aqueous biphasic extraction (ABE) process for soil decontamination involves the selective partitioning of solutes and fine particulates between two immiscible aqueous phases. The biphase system is generated by the appropriate combination of a water-soluble polymer (e.g., polyethlene glycol) with an inorganic salt (e.g., sodium carbonate). Selective partitioning results in 99 to 99.5% of the soil being recovered in the cleaned-soil fraction, while only 0.5 to 1% is recovered in the contaminant concentrate. The ABE process is best suited to the recovery of ultrafine, refractory material from the silt and clay fractions of soils. During continuous countercurrent extraction tests with soil samples from the Fernald Environmental Management Project site (Fernald, OH), particulate thorium was extracted and concentrated between 6- and 16-fold, while the uranium concentration was reduced from about 500 mg/kg to about 77 mg/kg. Carbonate leaching alone was able to reduce the uranium concentration only to 146 mg/kg. Preliminary estimates for treatment costs are approximately $160 per ton of dry soil. A detailed flowsheet of the ABE process is provided
Safwat, Engie; Hassan, Mohammad L; Saniour, Sayed; Zaki, Dalia Yehia; Eldeftar, Mervat; Saba, Dalia; Zazou, Mohamed
2018-05-01
Nanofibrillated cellulose, obtained from rice straw agricultural wastes was used as a substrate for the preparation of a new injectable and mineralized hydrogel for bone regeneration. Tetramethyl pyridine oxyl (TEMPO) oxidized nanofibrillated cellulose, was mineralized through the incorporation of a prepared and characterized biphasic calcium phosphate at a fixed ratio of 50 wt%. The TEMPO-oxidized rice straw nanofibrillated cellulose was characterized using transmission electron microscopy, Fourier transform infrared, and carboxylic content determination. The injectability and viscosity of the prepared hydrogel were evaluated using universal testing machine and rheometer testing, respectively. Cytotoxicity and alkaline phosphatase level tests on osteoblast like-cells for in vitro assessment of the biocompatibility were investigated. Results revealed that the isolated rice straw nanofibrillated cellulose is a nanocomposite of the cellulose nanofibers and silica nanoparticles. Rheological properties of the tested materials are suitable for use as injectable material and of nontoxic effect on osteoblast-like cells, as revealed by the positive alkaline phosphate assay. However, nanofibrillated cellulose/ biphasic calcium phosphate hydrogel showed higher cytotoxicity and lower bioactivity test results when compared to that of nanofibrillated cellulose.
Directory of Open Access Journals (Sweden)
Natalie Mrachacz-Kersting
2017-04-01
Full Text Available Paired associative stimulation (PAS protocols induce plastic changes within the motor cortex. The objectives of this study were to investigate PAS effects targeting the tibialis anterior (TA muscle using a biphasic transcranial magnetic stimulation (TMS pulse form and, to determine whether a reduced intensity of this pulse would lead to significant changes as has been reported for hand muscles using a monophasic TMS pulse. Three interventions were investigated: (1 suprathreshold PAbi-PAS (n = 11; (2 suprathreshold PAmono-PAS (n = 11 where PAS was applied using a biphasic or monophasic pulse form at 120% resting motor threshold (RMT; (3 subthreshold PAbi-PAS (n = 10 where PAS was applied as for (1 at 95% active motor threshold (AMT. The peak-to-peak motor evoked potentials (MEPs were quantified prior to, immediately following, and 30 min after the cessation of the intervention. TA MEP size increased significantly for all interventions immediately post (61% for suprathreshold PAbi-PAS, 83% for suprathreshold PAmono-PAS, 55% for subthreshold PAbi-PAS and 30 min after the cessation of the intervention (123% for suprathreshold PAbi-PAS, 105% for suprathreshold PAmono-PAS, 80% for subthreshold PAbi-PAS. PAS using a biphasic pulse form at subthreshold intensities induces similar effects to conventional PAS.
Knee Osteochondral Autologous Transplantation: Long-term MR findings and clinical correlations
International Nuclear Information System (INIS)
Tetta, Cecilia; Busacca, Maurizio; Moio, Antonio; Rinaldi, Raffaella; Delcogliano, Marco; Kon, Elizaveta; Filardo, Giuseppe; Marcacci, Maurilio; Albisinni, Ugo
2010-01-01
We evaluated long-term magnetic resonance imaging (MRI) features of Knee Osteochondral Autologous Transplantation (OAT)-Mosaicplasty and correlated MRI findings and clinical outcome. Twenty-four patients (mean age 29.9 ± 8.7, 70.8% male) undergoing arthroscopic OAT between 1997 and 2000 were prospectively enrolled. The International Cartilage Repair Society (ICRS)/International Knee Documentation Committee (IKDC) scores and Tegner scores were employed for clinical evaluation. The magnetic resonance observation of cartilage repair tissue (MOCART) was utilized for description and assessment of the repair tissue. Median follow up was 113 months (interquartile range [IQR] 106-122). MRI showed good survival of grafted cartilage in 62.5% of patients. The integration of the graft was complete in 75% of cases, while the repaired tissue was intact in 62.5% and had an homogeneous structure in 70.8%. The MOCART score significantly correlated with objective and subjective scores (p = 0.003 and p = 0.002). Contrastingly, overall MOCART showed no correlation with the Tegner score. MRI revealed to be a powerful tool for non-invasive long-term assessment of OAT.
Bierer, Julie Arenberg
2007-03-01
The efficacy of cochlear implants is limited by spatial and temporal interactions among channels. This study explores the spatially restricted tripolar electrode configuration and compares it to bipolar and monopolar stimulation. Measures of threshold and channel interaction were obtained from nine subjects implanted with the Clarion HiFocus-I electrode array. Stimuli were biphasic pulses delivered at 1020 pulses/s. Threshold increased from monopolar to bipolar to tripolar stimulation and was most variable across channels with the tripolar configuration. Channel interaction, quantified by the shift in threshold between single- and two-channel stimulation, occurred for all three configurations but was largest for the monopolar and simultaneous conditions. The threshold shifts with simultaneous tripolar stimulation were slightly smaller than with bipolar and were not as strongly affected by the timing of the two channel stimulation as was monopolar. The subjects' performances on clinical speech tests were correlated with channel-to-channel variability in tripolar threshold, such that greater variability was related to poorer performance. The data suggest that tripolar channels with high thresholds may reveal cochlear regions of low neuron survival or poor electrode placement.
Harb, Afif; von Horn, Alexander; Gocalek, Kornelia; Schäck, Luisa Marilena; Clausen, Jan; Krettek, Christian; Noack, Sandra; Neunaber, Claudia
2017-07-01
Due to the rising interest in Europe to treat large cartilage defects with osteochondrale allografts, research aims to find a suitable solution for long-term storage of osteochondral allografts. This is further encouraged by the fact that legal restrictions currently limit the use of the ingredients from animal or human sources that are being used in other regions of the world (e.g. in the USA). Therefore, the aim of this study was A) to analyze if a Lactated Ringer (LR) based solution is as efficient as a Dulbecco modified Eagle's minimal essential medium (DMEM) in maintaining chondrocyte viability and B) at which storage temperature (4°C vs. 37°C) chondrocyte survival of the osteochondral allograft is optimally sustained. 300 cartilage grafts were collected from knees of ten one year-old Black Head German Sheep. The grafts were stored in four different storage solutions (one of them DMEM-based, the other three based on Lactated Ringer Solution), at two different temperatures (4 and 37°C) for 14 and 56days. At both points in time, chondrocyte survival as well as death rate, Glycosaminoglycan (GAG) content, and Hydroxyproline (HP) concentration were measured and compared between the grafts stored in the different solutions and at the different temperatures. Independent of the storage solutions tested, chondrocyte survival rates were higher when stored at 4°C compared to storage at 37°C both after short-term (14days) and long-term storage (56days). At no point in time did the DMEM-based solution show a superior chondrocyte survival compared to lactated Ringer based solution. GAG and HP content were comparable across all time points, temperatures and solutions. LR based solutions that contain only substances that are approved in Germany may be just as efficient for storing grafts as the USA DMEM-based solution gold standard. Moreover, in the present experiment storage of osteochondral allografts at 4°C was superior to storage at 37°C. Copyright © 2017
Directory of Open Access Journals (Sweden)
Ilan Gur
2015-01-01
Conclusions: The noninvasive, easy-to-operate Biphasic Cuirass Ventilation device was effective in reducing OP-induced mortality and might be advantageous in an organophosphate mass casualty event. This finding should be validated in further investigations.
Ley, C J; Ekman, S; Hansson, K; Björnsdóttir, S; Boyde, A
2014-03-25
Osteochondral lesions in the joints of the distal tarsal region of young Icelandic horses provide a natural model for the early stages of osteoarthritis (OA) in low-motion joints. We describe and characterise mineralised and non-mineralised osteochondral lesions in left distal tarsal region joint specimens from twenty-two 30 ±1 month-old Icelandic horses. Combinations of confocal scanning light microscopy, backscattered electron scanning electron microscopy (including, importantly, iodine staining) and three-dimensional microcomputed tomography were used on specimens obtained with guidance from clinical imaging. Lesion-types were described and classified into groups according to morphological features. Their locations in the hyaline articular cartilage (HAC), articular calcified cartilage (ACC), subchondral bone (SCB) and the joint margin tissues were identified and their frequency in the joints recorded. Associations and correlations between lesion-types were investigated for centrodistal joints only. In centrodistal joints the lesion-types HAC chondrocyte loss, HAC fibrillation, HAC central chondrocyte clusters, ACC arrest and ACC advance had significant associations and strong correlations. These lesion-types had moderate to high frequency in centrodistal joints but low frequencies in tarsometatarsal and talocalcaneal-centroquartal joints. Joint margin lesion-types had no significant associations with other lesion-types in the centrodistal joints but high frequency in both the centrodistal and tarsometatarsal joints. The frequency of SCB lesion-types in all joints was low. Hypermineralised infill phase lesion-types were detected. Our results emphasise close associations between HAC and ACC lesions in equine centrodistal joints and the importance of ACC lesions in the development of OA in low-motion compression-loaded equine joints.
MDCT urography: experience with a bi-phasic excretory phase examination protocol
International Nuclear Information System (INIS)
Meindl, Thomas; Coppenrath, Eva; Degenhart, Christoph; Reiser, Maximilian F.; Mueller-Lisse, Ullrich G.; Mueller-Lisse, Ulrike L.
2007-01-01
The benefit of multidetector computed tomographic urography (MDCTU) for visualising early and late excretory phase (EP) upper urinary tract (UUT) opacification has been studied. UUT opacification was retrospectively evaluated in 45 bi-phasic four-row MDCTU examinations. The UUT was divided into intrarenal collecting system (IRCS), proximal, middle and distal ureter. Two independent readers rated opacification: 1, none; 2, partial; 3, complete. Numbers of segments and percentages of UUTs at each score were calculated for each EP and two EPs combined. Results of a single EP and of combined EPs were compared by Wilcoxon matched-pairs signed-ranks. IRCS and proximal ureter were at least partially opacified in each EP in >95%. The middle ureter was at least partially opacified in the early and late EP in 85% and 93%, respectively. The distal ureter was opacified in 65% (49/75) in the early EP and in 78% (59/75) in the late EP. Combining two EPs, non-opacified distal segments decreased to 9% (7/75). Significant improvement between a single EP and combining two EPs were found for the middle and distal ureter (P < 0.03). Bi-phasic MDCTU substantially improved opacification of the middle and distal ureter. IRCS and proximal ureter are reliably opacified with one EP. (orig.)
Hussein, Zanariah; Lim-Abrahan, Mary Anne; Jain, Anand B; Goh, Su Yen; Soewondo, Pradana
2013-04-01
To evaluate the safety and effectiveness of biphasic insulin aspart 30 (BIAsp 30) in ASEAN type 2 diabetes (T2D) patients switched from biphasic human insulin (BHI) in the non-interventional 24-week A₁chieve study. Indonesian, Malaysian, Filipino and Singaporean patients switched from BHI to BIAsp 30 at their physicians' discretion were included. The incidence of serious adverse drug reactions (SADRs), including major hypoglycaemia was the primary endpoint. Changes in hypoglycaemia, glycated haemoglobin A1c (HbA1c), fasting plasma glucose (FPG), postprandial plasma glucose (PPPG), lipids, body weight and systolic blood pressure were also evaluated. Quality of life (QoL) was measured using the EQ-5D questionnaire. For the 465 patients included (mean ± SD age: 56 ± 10.3 years, diabetes duration: 9.7 ± 7.1 years, baseline HbA1c: 9.4 ± 1.8%), the mean pre-study BHI dose was 0.62 ± 0.28 IU/kg and 63.4% were dosing BHI twice daily (bid). The mean baseline BIAsp 30 dose was 0.65 ± 0.27 U/kg, titrated up to 0.71 ± 0.28 U/kg over 24 weeks, and most patients continued bid dosing. No SADRs or major hypoglycaemic episodes were reported. The proportion of patients reporting overall hypoglycaemia decreased significantly from 10.8% at baseline to 3.4% at Week 24 (p ASEAN subgroup poorly controlled on BHI. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Gagala, J; Tarczynska, M; Gaweda, K; Matuszewski, L
2014-09-01
Osteonecrosis of the femoral head is an entity which occurs mainly in young and active patients aged between 20 and 50. The success of hip joint preserving treatments ranges from 15% to 50% depending on the stage and amount of osteonecrotic lesion. Total hip replacement is indicated in late post-collapse hips but it has unsatisfactory survival because of the wear and osteolysis in young and active patients. Osteochondral allografts have been reported in the treatment of large articular lesions with defects in underlying bone in knee, talus and shoulder. By combining osteoconductive properties of osteochondral allograft with osteogenic abilities of bone marrow-derived mesenchymal cells it has a potential to be an alternative to an autologous graft. The adjunct of hinged joint distraction should minimize stresses in subchondral bone to promote creeping substitution and prevent femoral head collapse. Unlike current treatment modalities, it would provide both structural support and allow bony and articular substitution. Copyright © 2014 Elsevier Ltd. All rights reserved.
de Sena, Amanda Reges; Barros Oliveira, Flávio Manoel; Campos Leite, Tonny Cley; Evaristo da Silva Nascimento, Talita Camila; Moreira, Keila Aparecida; de Assis, Sandra Aparecida
2017-10-21
The aims of the current study are to assess the influence of polyethylene glycol (PEG) concentration, molar mass, pH, and citrate concentrations on aqueous biphasic systems based on 2 4 factorial designs, as well as to check their capacity to purify tannase secreted by Aspergillus tamarii URM 7115. Tannase was produced through submerged fermentation at 26°C for 67 h in Czapeck-Dox modified broth and added with yeast extract and tannic acid. The factorial design was followed to assess the influence of PEG molar mass (M PEG 600; 4,000 and 8,000 g/ mol), and PEG (C PEG 20.0; 22.0 and 24.0% w/w) and citrate concentrations (C CIT 15.0, 17.5, and 20.0%, w/w), as well as of pH (6.0, 7.0, and 8.0) on the response variables; moreover, partition coefficient (K), yield (Y), and purification factor (PF) were analyzed. The most suitable parameters to purify tannase secreted by A. tamarii URM 7115 through a biphasic system were 600 (g/mol) M PEG , 24% (w/w) C PEG , 15% (w/w) C CIT at pH 6.0 and they resulted in 6.33 enzyme partition, 131.25% yield, 19.80 purification factor and 195.08 selectivity. Tannase secreted by A. tamarii URM 7115 purified through aqueous biphasic systems composed of PEG/citrate can be used for industrial purposes, since it presents suitable purification factor and yield.
Investigation of the transport properties of metals in the biphase region
International Nuclear Information System (INIS)
Oreshkin, V. I.; Rousskikh, A. G.; Chaikovsky, S. A.; Oreshkin, E. V.
2010-01-01
Results of experiments on electrical wire explosion are presented and processes of stratum formation and decay are analyzed in this paper. A procedure of calculating the transport coefficients from the rate of stratum damping is described. It is demonstrated that values of the transport coefficients for metals are not an unambiguous function of the material state in the biphase region for characteristic times of ∼10 -7 s but depend on the process prehistory.
A promising tritium breeding material: Nanostructured 2Li2TiO3-Li4SiO4 biphasic ceramic pebbles
Dang, Chen; Yang, Mao; Gong, Yichao; Feng, Lan; Wang, Hailiang; Shi, Yanli; Shi, Qiwu; Qi, Jianqi; Lu, Tiecheng
2018-03-01
As an advanced tritium breeder material for the fusion reactor blanket of the International Thermonuclear Experimental Reactor (ITER), Li2TiO3-Li4SiO4 biphasic ceramic has attracted widely attention due to its merits. In this paper, the uniform precursor powders were prepared by hydrothermal method, and nanostructured 2Li2TiO3-Li4SiO4 biphasic ceramic pebbles were fabricated by an indirect wet method at the first time. In addition, the composition dependence (x/y) of their microstructure characteristics and mechanical properties were investigated. The results indicated that the crush load of biphasic ceramic pebbles was better than that of single phase ceramic pebbles under identical conditions. The 2Li2TiO3-Li4SiO4 ceramic pebbles have good morphology, small grain size (90 nm), satisfactory crush load (37.8 N) and relative density (81.8 %T.D.), which could be a promising breeding material in the future fusion reactor.
Modern cartilage imaging of the ankle; Moderne Knorpelbildgebung des Sprunggelenks
Energy Technology Data Exchange (ETDEWEB)
Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph [University Hospital Heidelberg (Germany). Diagnostic and Interventional Radiology; Jungmann, Pia M. [Technical Univ. Munich (Germany). Radiology; Kuni, Benita [Ortho-Zentrum Karlsruhe (Germany). Orthopedics and Trauma Surgery
2017-10-15
Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and
Modern cartilage imaging of the ankle
International Nuclear Information System (INIS)
Weber, Marc-Andre; Wuennemann, Felix; Rehnitz, Christoph; Jungmann, Pia M.; Kuni, Benita
2017-01-01
Talar osteochondral lesions are an important risk factor for the development of talar osteoarthritis. Furthermore, osteochondral lesions might explain persistent ankle pain. Early diagnosis of accompanying chondral defects is important to establish the optimal therapy strategy and thereby delaying or preventing the onset of osteoarthritis. The purpose of this review is to explain modern cartilage imaging with emphasis of MR imaging as well as the discussion of more sophisticated imaging studies like CT-arthrography or functional MR imaging. Pubmed literature search concerning: osteochondral lesions, cartilage damage, ankle joint, talus, 2 D MR imaging, 3 D MR imaging, cartilage MR imaging, CT-arthrography, cartilage repair, microfracture, OATS, MACT. Dedicated MR imaging protocols to delineate talar cartilage and the appearance of acute and chronic osteochondral lesions were discussed. Recent developments of MR imaging, such as isotropic 3 D imaging that has a higher signal-to noise ratio when compared to 2 D imaging, and specialized imaging methods such as CT-arthrography as well as functional MR imaging were introduced. Several classifications schemes and imaging findings of osteochondral lesions that influence the conservative or surgical therapy strategy were discussed. MRI enables after surgery the non-invasive assessment of the repair tissue and the success of implantation. Key points: Modern MRI allows for highly resolved visualization of the articular cartilage of the ankle joint and of subchondral pathologies. Recent advances in MRI include 3 D isotropic ankle joint imaging, which deliver higher signal-to-noise ratios of the cartilage and less partial volume artifacts when compared with standard 2 D sequences. In case of osteochondral lesions MRI is beneficial for assessing the stability of the osteochondral fragment and for this discontinuity of the cartilage layer is an important factor. CT-arthrography can be used in case of contraindications of MRI and
Directory of Open Access Journals (Sweden)
Haroun Hassan Shaikh
2015-12-01
Full Text Available Osteochondritis dissecans(OCD of the knee is identified with increasing frequency in the adolescent patient. Left untreated, OCD can cause significant impairment and restriction in physical activity and development of osteoarthritis at an early age. The diagnosis of lesions of OCD can be confirmed on plain radiographs. MRI has emerged as the gold standard to evaluate the stability of the lesion and the integrity of the overlying articular cartilage. Treatment of OCD lesions depend on the stability of the lesion. Stable lesions can be treated conservatively by physical activity modification and immobilization. Unstable lesions and stable lesions not responding to conservative measures should be treated surgically. Surgical options range from arthroscopic drilling, either transarticular or extra-articular drilling for stable lesions or salvage procedures such as autologous chondrocyte transplantation (ACT, mosaicplasty to restore joint and cartilage congruency.
Shendkar, Chandrashekhar; Lenka, Prasanna K; Biswas, Abhishek; Kumar, Ratnesh; Mahadevappa, Manjunatha
2015-10-01
Functional electric stimulators that produce near-ideal, charge-balanced biphasic stimulation waveforms with interphase delay are considered safer and more efficacious than conventional stimulators. An indigenously designed, low-cost, portable FES device named InStim is developed. It features a charge-balanced biphasic single channel. The authors present the complete design, mathematical analysis of the circuit and the clinical evaluation of the device. The developed circuit was tested on stroke patients affected by foot drop problems. It was tested both under laboratory conditions and in clinical settings. The key building blocks of this circuit are low dropout regulators, a DC-DC voltage booster and a single high-power current source OP-Amp with current-limiting capabilities. This allows the device to deliver high-voltage, constant current, biphasic pulses without the use of a bulky step-up transformer. The advantages of the proposed design over the currently existing devices include improved safety features (zero DC current, current-limiting mechanism and safe pulses), waveform morphology that causes less muscle fatigue, cost-effectiveness and compact power-efficient circuit design with minimal components. The device is also capable of producing appropriate ankle dorsiflexion in patients having foot drop problems of various Medical Research Council scale grades.
Koster, Rudolph W.; Dorian, Paul; Chapman, Fred W.; Schmitt, Paul W.; O'Grady, Sharon G.; Walker, Robert G.
2004-01-01
Background We compared efficacy of and pain felt after biphasic truncated exponential (BTE) and monophasic damped sine (MDS) shocks in patients undergoing external cardioversion of atrial fibrillation (AF). Methods Patients with AF were randomized to BTE or MDS waveform cardioversion. Successive
International Nuclear Information System (INIS)
He Xiaoqing; Chen Rui; Yang Ping; Li Aiping; Zhou Jianwei; Liu Qizhan
2007-01-01
Biphasic dose-response relationship induced by environmental agents is often characterized with the effect of low-dose stimulation and high-dose inhibition. Some studies showed that arsenite may induce cell proliferation and apoptosis via biphasic dose-response relationship in human cells; however, mechanisms underlying this phenomenon are not well understood. In the present study, we aimed at investigating the relationship between biphasic effect of arsenite on cell proliferation and apoptosis and activation of JNK and ERK1/2 in human embryo lung fibroblast (HELF) cells. Our results demonstrated that cell proliferation may be stimulated at lower concentrations (0.1 and 0.5 μM) arsenite but inhibited at higher concentrations (5 and 10 μM). When cell apoptosis was used as the endpoint, the concentration-response curves were changed to U-shapes. During stimulation phospho-JNK levels were significantly increased at 3, 6, and 12 h after 0.1 or 0.5 μM arsenite exposure. Phospho-ERK1/2 levels were increased with different concentrations (0.1-10 μM) of arsenite at 6, 12, and 24 h. Blocking of JNK pathway with 20 μM SP600125 or ERK1/2 by 100 μM PD98059 significantly inhibited biphasic effect of arsenite in cells. Data in the present study suggest that activation of JNK and ERK1/2 may be involved in biphasic effect of arsenite when measuring cell proliferation and apoptosis in HELF cells. JNK activation seems to play a more critical role than ERK1/2 activation in the biphasic process
Preparation of highly infective Leishmania promastigotes by cultivation on SNB-9 biphasic medium
Czech Academy of Sciences Publication Activity Database
Grekov, Igor; Svobodová, M.; Nohýnková, E.; Lipoldová, Marie
2011-01-01
Roč. 87, č. 3 (2011), s. 273-277 ISSN 0167-7012 R&D Projects: GA MŠk(CZ) LC06009; GA ČR GA310/08/1697 Institutional research plan: CEZ:AV0Z50520514 Keywords : Leishmania * SNB-9 * biphasic culture medium * parasite infectivity Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.086, year: 2011
Chen, Bihua; Yu, Tao; Ristagno, Giuseppe; Quan, Weilun; Li, Yongqin
2014-10-01
Defibrillation current has been shown to be a clinically more relevant dosing unit than energy. However, the effects of average and peak current in determining shock outcome are still undetermined. The aim of this study was to investigate the relationship between average current, peak current and defibrillation success when different biphasic waveforms were employed. Ventricular fibrillation (VF) was electrically induced in 22 domestic male pigs. Animals were then randomized to receive defibrillation using one of two different biphasic waveforms. A grouped up-and-down defibrillation threshold-testing protocol was used to maintain the average success rate of 50% in the neighborhood. In 14 animals (Study A), defibrillations were accomplished with either biphasic truncated exponential (BTE) or rectilinear biphasic waveforms. In eight animals (Study B), shocks were delivered using two BTE waveforms that had identical peak current but different waveform durations. Both average and peak currents were associated with defibrillation success when BTE and rectilinear waveforms were investigated. However, when pathway impedance was less than 90Ω for the BTE waveform, bivariate correlation coefficient was 0.36 (p=0.001) for the average current, but only 0.21 (p=0.06) for the peak current in Study A. In Study B, a high defibrillation success (67.9% vs. 38.8%, pcurrent (14.9±2.1A vs. 13.5±1.7A, pcurrent unchanged. In this porcine model of VF, average current was better than peak current to be an adequate parameter to describe the therapeutic dosage when biphasic defibrillation waveforms were used. The institutional protocol number: P0805. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Mangano, Carlo; Sinjari, Bruna; Shibli, Jamil A; Mangano, Francesco; Hamisch, Sabine; Piattelli, Adriano; Perrotti, Vittoria; Iezzi, Giovanna
2015-06-01
By mixing hydroxyapatite (HA) and tricalcium phosphate (TCP), biphasic calcium phosphate ceramics can be obtained, and by varying their ratio it is possible to tailor the characteristics of the biomaterial. The aim of the present human study was to evaluate the histological and radiographical aspects of bone formation in maxillary sinus augmentation using a 30/70 HA-beta-TCP with a reticular structure. A total of 12 patients, undergoing two-stage sinus augmentation procedure using HA-beta-TCP at a ratio of 30/70, were included in the present study. After a 6-month healing period, during implant insertion, radiographical analysis was performed, and then the bone core biopsies were harvested and processed for histology. At radiographic evaluation, the bone gain was on average 6.85 ± 0.60 mm. HA-beta-TCP 30/70 appeared to be lined by newly formed bone, with no gaps at the interface. The histomorphometric analysis revealed 26 ± 2% of residual grafted biomaterial, 29 ± 3% of newly formed bone, and 45 ± 2% of marrow spaces. The present results indicate histologically the high biocompatibility and osteoconductivity of HA-beta-TCP 30/70, and clinically its successful use for sinus augmentation procedures. © 2013 Wiley Periodicals, Inc.
A comparison of surgical exposures for posterolateral osteochondral lesions of the talar dome.
Mayne, Alistair I W; Lawton, Robert; Reidy, Michael J; Harrold, Fraser; Chami, George
2018-04-01
Perpendicular access to the posterolateral talar dome for the management of osteochondral defects is difficult. We examined exposure available from each of four surgical approaches. Four surgical approaches were performed on 9 Thiel-embalmed cadavers: anterolateral approach with arthrotomy; anterolateral approach with anterior talo-fibular ligament (ATFL) release; anterolateral approach with antero-lateral tibial osteotomy; and anterolateral approach with lateral malleolus osteotomy. The furthest distance posteriorly allowing perpendicular access with a 2mm k-wire was measured. An anterolateral approach with arthrotomy provided a mean exposure of the anterior third of the lateral talar dome. A lateral malleolus osteotomy provided superior exposure (81.5% vs 58.8%) compared to an anterolateral tibial osteotomy. Only the anterior half of the lateral border of the talar dome could be accessed with an anterolateral approach without osteotomy. A fibular osteotomy provided best exposure to the posterolateral aspect of the talar dome. Copyright © 2016 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Directory of Open Access Journals (Sweden)
CJ Ley
2014-03-01
Full Text Available Osteochondral lesions in the joints of the distal tarsal region of young Icelandic horses provide a natural model for the early stages of osteoarthritis (OA in low-motion joints. We describe and characterise mineralised and non-mineralised osteochondral lesions in left distal tarsal region joint specimens from twenty-two 30 ±1 month-old Icelandic horses. Combinations of confocal scanning light microscopy, backscattered electron scanning electron microscopy (including, importantly, iodine staining and three-dimensional microcomputed tomography were used on specimens obtained with guidance from clinical imaging. Lesion-types were described and classified into groups according to morphological features. Their locations in the hyaline articular cartilage (HAC, articular calcified cartilage (ACC, subchondral bone (SCB and the joint margin tissues were identified and their frequency in the joints recorded. Associations and correlations between lesion-types were investigated for centrodistal joints only. In centrodistal joints the lesion-types HAC chondrocyte loss, HAC fibrillation, HAC central chondrocyte clusters, ACC arrest and ACC advance had significant associations and strong correlations. These lesion-types had moderate to high frequency in centrodistal joints but low frequencies in tarsometatarsal and talocalcaneal-centroquartal joints. Joint margin lesion-types had no significant associations with other lesion-types in the centrodistal joints but high frequency in both the centrodistal and tarsometatarsal joints. The frequency of SCB lesion-types in all joints was low. Hypermineralised infill phase lesion-types were detected. Our results emphasise close associations between HAC and ACC lesions in equine centrodistal joints and the importance of ACC lesions in the development of OA in low-motion compression-loaded equine joints.
Effect of nasal continuous and biphasic positive airway pressure on lung volume in preterm infants
Miedema, Martijn; van der Burg, Pauline S.; Beuger, Sabine; de Jongh, Frans H.; Frerichs, Inez; van Kaam, Anton H.
2013-01-01
To monitor regional changes in end-expiratory lung volume (EELV), tidal volumes, and their ventilation distribution during different levels of nasal continuous positive airway pressure (nCPAP) and nasal biphasic positive airway pressure (BiPAP) in stable preterm infants. By using electrical
Font Tellado, Sònia; Bonani, Walter; Balmayor, Elizabeth R; Foehr, Peter; Motta, Antonella; Migliaresi, Claudio; van Griensven, Martijn
2017-08-01
Tissue engineering is an attractive strategy for tendon/ligament-to-bone interface repair. The structure and extracellular matrix composition of the interface are complex and allow for a gradual mechanical stress transfer between tendons/ligaments and bone. Thus, scaffolds mimicking the structural features of the native interface may be able to better support functional tissue regeneration. In this study, we fabricated biphasic silk fibroin scaffolds designed to mimic the gradient in collagen molecule alignment present at the interface. The scaffolds had two different pore alignments: anisotropic at the tendon/ligament side and isotropic at the bone side. Total porosity ranged from 50% to 80% and the majority of pores (80-90%) were ligament, enthesis, and cartilage markers significantly changed depending on pore alignment in each region of the scaffolds. In conclusion, the biphasic scaffolds fabricated in this study show promising features for tendon/ligament-to-bone tissue engineering.
Koenig, Geraldine; Ozcelik, Hayriye; Haesler, Lisa; Cihova, Martina; Ciftci, Sait; Dupret-Bories, Agnes; Debry, Christian; Stelzle, Martin; Lavalle, Philippe; Vrana, Nihal Engin
2016-03-01
Porous titanium implants are widely used in dental, orthopaedic and otorhinolaryngology fields to improve implant integration to host tissue. A possible step further to improve the integration with the host is the incorporation of autologous cells in porous titanium structures via cell-laden hydrogels. Fast gelling hydrogels have advantageous properties for in situ applications such as localisation of specific cells and growth factors at a target area without dispersion. The ability to control the cell types in different regions of an implant is important in applications where the target tissue (i) has structural heterogeneity (multiple cell types with a defined spatial configuration with respect to each other); (ii) has physical property gradients essential for its function (such as in the case of osteochondral tissue transition). Due to their near immediate gelation, such gels can also be used for site-specific modification of porous titanium structures, particularly for implants which would face different tissues at different locations. Herein, we describe a step by step design of a model system: the model cell-laden gel-containing porous titanium implants in the form of titanium microbead/hydrogel (maleimide-dextran or maleimide-PVA based) microhybrids. These systems enable the determination of the effect of titanium presence on gel properties and encapsulated cell behaviour as a miniaturized version of full-scale implants, providing a system compatible with conventional analysis methods. We used a fibroblast/vascular endothelial cell co-cultures as our model system and by utilising single microbeads we have quantified the effect of gel microenvironment (degradability, presence of RGD peptides within gel formulation) on cell behaviour and the effect of the titanium presence on cell behaviour and gel formation. Titanium presence slightly changed gel properties without hindering gel formation or affecting cell viability. Cells showed a preference to move towards
Li, Minyuan Miller; Dinca, Mircea
2013-01-01
Cathodic electrodeposition lends itself to the formation of biphasic metal–organic framework thin films at room temperature from single deposition baths using potential bias as the main user input. Depending on the applied potential, we selectively deposit two different phases as either bulk mixtures or bilayer films.
Obtaining of ceramics biphasic dense and porous
International Nuclear Information System (INIS)
Pallone, E.M.J.A.; Rigo, E.C.S.; Fraga, A.F.
2010-01-01
Among the bioceramic hydroxyapatite (HAP) and beta-tricalcium phosphate (beta-TCP) are materials commonly used in biomedical field. Their combined properties result in a material with absorbable and at the same time with bioactive surface. Called biphasic ceramics such materials respond more quickly when exposed to physiological environment. In this work, powders of HAP/beta-TCP were obtained by chemical precipitation. After obtaining the post-phase was added at a ratio of 0, 15% and 30w% aqueous solutions of corn starch in order to obtain porous bodies. After mixing the resulting solutions were dried, resigned in tablet form and sintered at 1300 deg C. The initial powder was characterized by X-ray diffraction with Rietveld refinement to quantify the phases present. Bodies-of-evidence has been characterized by calculating the bulk density, X-ray diffraction (XRD), scanning electron microscopy and diametral compression. (author)
Energy Technology Data Exchange (ETDEWEB)
Wang, Yujia; Shen, Yueyue; Qiu, Yunfei; Zhang, Ting; Liao, Yang; Zhao, Shilin; Ma, Jun, E-mail: 1044208419@qq.com; Mao, Hui, E-mail: rejoice222@163.com [Sichuan Normal University, College of Chemistry and Materials Science (China)
2016-10-15
Noble metal nanoparticles are promising candidates to replace conventional bulk counterparts owing to their high activity and selectivity. To enable catalyst recovery, noble metal nanoparticles are often supported onto solid matrices to prepare heterogeneous catalyst. Although recycle of noble metal nanoparticles is realized by heterogenization, a loss of activity is usually encountered. In the present investigation, Pt nanoparticles with tunable particle size (1.85–2.80 nm) were facilely prepared by using polyphenols as amphiphilic stabilizers. The as-prepared Pt nanoparticles colloid solution could be used as highly active catalyst in aqueous–organic biphasic catalysis. The phenolic hydroxyls of polyphenols could constrain Pt nanoparticles in aqueous phase, and simultaneously, the aromatic scaffold of polyphenols ensured effective interactions between substrates and Pt nanoparticles. As a consequence, the obtained polyphenols-stabilized Pt nanoparticles exhibited high activity and cycling stability in biphasic hydrogenation of a series of unsaturated compounds. Compared with conventional heterogeneous Pt-C and Pt-Al{sub 2}O{sub 3} catalysts, polyphenols-stabilized Pt nanoparticles showed obvious advantage both in activity and cycling stability.
Directory of Open Access Journals (Sweden)
Dimitris S. Argyropoulos
2013-07-01
Full Text Available 5-Halomethylfurfurals can be considered as platform chemicals of high reactivity making them useful for the preparation of a variety of important compounds. In this study, a one-pot route for the conversion of carbohydrates into 5-chloromethylfurfural (CMF in a simple and efficient (HCl-H3PO4/CHCl3 biphasic system has been investigated. Monosaccharides such as D-fructose, D-glucose and sorbose, disaccharides such as sucrose and cellobiose and polysaccharides such as cellulose were successfully converted into CMF in satisfactory yields under mild conditions. Our data shows that when using D-fructose the optimum yield of CMF was about 47%. This understanding allowed us to extent our work to biomaterials, such as wood powder and wood pulps with yields of CMF obtained being comparable to those seen with some of the enumerated mono and disaccharides. Overall, the proposed (HCl-H3PO4/CHCl3 optimized biphasic system provides a simple, mild, and cost-effective means to prepare CMF from renewable resources.
International Nuclear Information System (INIS)
Wang, Yujia; Shen, Yueyue; Qiu, Yunfei; Zhang, Ting; Liao, Yang; Zhao, Shilin; Ma, Jun; Mao, Hui
2016-01-01
Noble metal nanoparticles are promising candidates to replace conventional bulk counterparts owing to their high activity and selectivity. To enable catalyst recovery, noble metal nanoparticles are often supported onto solid matrices to prepare heterogeneous catalyst. Although recycle of noble metal nanoparticles is realized by heterogenization, a loss of activity is usually encountered. In the present investigation, Pt nanoparticles with tunable particle size (1.85–2.80 nm) were facilely prepared by using polyphenols as amphiphilic stabilizers. The as-prepared Pt nanoparticles colloid solution could be used as highly active catalyst in aqueous–organic biphasic catalysis. The phenolic hydroxyls of polyphenols could constrain Pt nanoparticles in aqueous phase, and simultaneously, the aromatic scaffold of polyphenols ensured effective interactions between substrates and Pt nanoparticles. As a consequence, the obtained polyphenols-stabilized Pt nanoparticles exhibited high activity and cycling stability in biphasic hydrogenation of a series of unsaturated compounds. Compared with conventional heterogeneous Pt-C and Pt-Al 2 O 3 catalysts, polyphenols-stabilized Pt nanoparticles showed obvious advantage both in activity and cycling stability.
Haider, Mansoor A; Guilak, Farshid
2007-06-15
Articular cartilage exhibits viscoelasticity in response to mechanical loading that is well described using biphasic or poroelastic continuum models. To date, boundary element methods (BEMs) have not been employed in modeling biphasic tissue mechanics. A three dimensional direct poroelastic BEM, formulated in the Laplace transform domain, is applied to modeling stress relaxation in cartilage. Macroscopic stress relaxation of a poroelastic cylinder in uni-axial confined compression is simulated and validated against a theoretical solution. Microscopic cell deformation due to poroelastic stress relaxation is also modeled. An extended Laplace inversion method is employed to accurately represent mechanical responses in the time domain.
Hoemann, C D; Sun, J; McKee, M D; Chevrier, A; Rossomacha, E; Rivard, G-E; Hurtig, M; Buschmann, M D
2007-01-01
We have previously shown that microfractured ovine defects are repaired with more hyaline cartilage when the defect is treated with in situ-solidified implants of chitosan-glycerol phosphate (chitosan-GP) mixed with autologous whole blood. The objectives of this study were (1) to characterize chitosan-GP/blood clots in vitro, and (2) to develop a rabbit marrow stimulation model in order to determine the effects of the chitosan-GP/blood implant and of debridement on the formation of incipient cartilage repair tissue. Blood clots were characterized by histology and in vitro clot retraction tests. Bilateral 3.5 x 4 mm trochlear defects debrided into the calcified layer were pierced with four microdrill holes and filled with a chitosan-GP/blood implant or allowed to bleed freely as a control. At 1 day post-surgery, initial defects were characterized by histomorphometry (n=3). After 8 weeks of repair, osteochondral repair tissues between or through the drill holes were evaluated by histology, histomorphometry, collagen type II expression, and stereology (n=16). Chitosan-GP solutions structurally stabilized the blood clots by inhibiting clot retraction. Treatment of drilled defects with chitosan-GP/blood clots led to the formation of a more integrated and hyaline repair tissue above a more porous and vascularized subchondral bone plate compared to drilling alone. Correlation analysis of repair tissue between the drill holes revealed that the absence of calcified cartilage and the presence of a porous subchondral bone plate were predictors of greater repair tissue integration with subchondral bone (Phyaline and integrated repair tissue associated with a porous subchondral bone replete with blood vessels. Concomitant regeneration of a vascularized bone plate during cartilage repair could provide progenitors, anabolic factors and nutrients that aid in the formation of hyaline cartilage.
Berti, L; Vannini, F; Lullini, G; Caravaggi, P; Leardini, A; Giannini, S
2013-09-01
Severe post-traumatic ankle arthritis poses a reconstructive challenge in active patients. Whereas traditional surgical treatments, i.e. arthrodesis and arthroplasty, provide good pain relief, arthrodesis is associated to functional and psychological limitations, and arthroplasty is prone to failure in the active patient. More recently the use of bipolar fresh osteochondral allografts transplantation has been proposed as a promising alternative to the traditional treatments. Preliminary short- and long-term clinical outcomes for this procedure have been reported, but no functional evaluations have been performed to date. The clinical and functional outcomes of a series of 10 patients who underwent allograft transplantation at a mean follow-up of 14 months are reported. Clinical evaluation was performed with the AOFAS score, functional assessment by state-of-the-art gait analysis. The clinical score significantly improved from a median of 54 (range 12-65) pre-op to 76.5 (range 61-86) post-op (p=0.002). No significant changes were observed for the spatial-temporal parameters, but motion at the hip and knee joints during early stance, and the range of motion of the ankle joint in the frontal plane (control: 13.8°±2.9°; pre-op: 10.4°±3.1°, post-op: 12.9°±4.2°; p=0.02) showed significant improvements. EMG signals revealed a good recovery in activation of the biceps femoris. This study showed that osteochondral allograft transplantation improves gait patterns. Although re-evaluation at longer follow-ups is required, this technique may represent the right choice for patients who want to delay the need for more invasive joint reconstruction procedures. Copyright © 2013 Elsevier B.V. All rights reserved.
Roßbach, Björn Peter; Paulus, Alexander Christoph; Niethammer, Thomas Richard; Wegener, Veronika; Gülecyüz, Mehmet Fatih; Jansson, Volkmar; Müller, Peter Ernst; Utzschneider, Sandra
2016-04-01
The aim of this study was to assess the reliability of preoperative MRI for the staging of osteochondritis dissecans (OCD) lesions of the knee and the talus in juvenile patients, using arthroscopy as the gold standard of diagnosis. Sixty-three juvenile patients (range 8-16 years) with an OCD of the knee or the talus underwent arthroscopy after MRI. In 54/9 out of 63 cases, 1.5/3 T MR scanners were used. The OCD stage was classified according the staging criteria of Dipaola et al. Arthroscopic findings were compared with MRI reports in each patient. From the 63 juvenile patients, MRI/arthroscopy revealed a stage I OCD in 4/19 patients, stage II in 31/22 patients, stage III in 22/9 patients and stage IV in 6/6 patients. No osteochondral pathology was evident in arthroscopy in seven out of 63 patients. The overall accuracy of preoperative MRI in staging an OCD lesion of the knee or the talus was 41.3%. In 33 out of 63 patients (52.4%), arthroscopy revealed a lower OCD stage than in the preoperative MRI grading, and in four out of 63 cases (6.4%), the intraoperative arthroscopic grading was worse than in preoperative MRI prior to surgery. The utilization of the 3 T MRI provided a correct diagnosis with 44.4%. Even with today's modern MRI scanners, it is not possible to predict an accurate OCD stage in children. The children's orthopaedist should not solely rely on the MRI when it comes to the decision to further conservative or surgical treatment of a juvenile OCD, but rather should take surgical therapy in consideration within persisting symptoms despite a low OCD stage provided by MRI. III.
A model of auditory nerve responses to electrical stimulation
DEFF Research Database (Denmark)
Joshi, Suyash Narendra; Dau, Torsten; Epp, Bastian
Cochlear implants (CI) stimulate the auditory nerve (AN) with a train of symmetric biphasic current pulses comprising of a cathodic and an anodic phase. The cathodic phase is intended to depolarize the membrane of the neuron and to initiate an action potential (AP) and the anodic phase to neutral......Cochlear implants (CI) stimulate the auditory nerve (AN) with a train of symmetric biphasic current pulses comprising of a cathodic and an anodic phase. The cathodic phase is intended to depolarize the membrane of the neuron and to initiate an action potential (AP) and the anodic phase......-and-fire neuron with two partitions responding individually to anodic and cathodic stimulation. Membrane noise was parameterized based on reported relative spread of AN neurons. Firing efficiency curves and spike-latency distributions were simulated for monophasic and symmetric biphasic stimulation...
Mihatovic, Ilja; Becker, Jürgen; Golubovic, Vladimir; Hegewald, Andrea; Schwarz, Frank
2012-03-01
To assess the influence of two barrier membranes and two bone graft substitutes on staged guided bone regeneration and osseointegration of titanium implants in dogs. Saddle-type defects were prepared in the lower jaws of 6 fox hounds and randomly filled with a natural bone mineral (NBM) and a biphasic calcium phosphate (SBC) and allocated to either an in situ gelling polyethylene glycol (PEG) or a collagen membrane (CM). At 8 weeks, modSLA titanium implants were inserted and left to heal in a submerged position. At 8+2 weeks, respectively, dissected blocks were processed for histomorphometrical analysis (e.g., mineralized tissue [MT], bone-to-implant contact [BIC]). The mean MT values (mm2) and BIC values (%) tended to be higher in the PEG groups (MT: NBM [3.4±1.7]; SBC [4.2±2]/BIC: NBM [67.7±16.9]; SBC [66.9±17.8]) when compared with the corresponding CM groups (MT: NBM [2.5±0.8]; SBC [2.3±1.6]/BIC: NBM [54.1±22.6]; SBC [61±8.7]). These differences, however, did not reach statistical significance. It was concluded that all augmentation procedures investigated supported bone regeneration and staged osseointegration of modSLA titanium implants. © 2011 John Wiley & Sons A/S.
Directory of Open Access Journals (Sweden)
Pal Madhumay
2010-01-01
Full Text Available We report a case of biphasic synovial sarcoma of the mediastinum, a very rare tumor, in a 12-year-old boy with left-sided chest pain of 3 years duration at presentation. Chest X-ray showed left-sided opacity with loss of cardiac silhouette and the mediastinum deviated to the opposite side. Computed tomography (CT of thorax showed left-sided posterior mediastinal mass with left-sided pleural effusion and pleural thickening. CT guided fine needle aspiration cytology (FNAC from the mass reported it as spindle cell variant of adenocarcinoma. Ultrasonography (USG of the whole abdomen revealed no abnormality. The mediastinal tumor was resected by left thoracotomy and histopathological report confirmed it to be a biphasic synovial sarcoma with capsule invasion at places.
Biphasic products of dicalcium phosphate-rich cement with injectability and nondispersibility
International Nuclear Information System (INIS)
Ko, Chia-Ling; Chen, Jian-Chih; Hung, Chun-Cheng; Wang, Jen-Chyan; Tien, Yin-Chun; Chen, Wen-Cheng
2014-01-01
In this study, a calcium phosphate cement was developed using tetracalcium phosphate and surface-modified dicalcium phosphate anhydrous (DCPA). This developed injectable bone graft substitute can be molded to the shape of the bone cavity and set in situ through the piping system that has an adequate mechanical strength, non-dispersibility, and biocompatibility. The materials were based on the modified DCPA compositions of calcium phosphate cement (CPC), where the phase ratio of the surface-modified DCPA is higher than that of the conventional CPC for forming dicalcium phosphate (DCP)-rich cement. The composition and morphology of several calcium phosphate cement specimens during setting were analyzed via X-ray diffractometry and transmission electron microscopy coupled with an energy dispersive spectroscopy system. The compressive strength of DCP-rich CPCs was greater than 30 MPa after 24 h of immersion in vitro. The reaction of the CPCs produced steady final biphasic products of DCPs with apatite. The composites of calcium phosphate cements derived from tetracalcium phosphate mixed with surface-modified DCPA exhibited excellent mechanical properties, injectability, and interlocking forces between particles, and they also featured nondispersive behavior when immersed in a physiological solution. - Highlights: • Bone cement precursor with nanocrystals is characterized. • DCP-rich CPCs with nanocrystals exhibited biphasic product phases. • Nanocrystals in cement significantly affected the interlocking ability. • Nanocrystals in cement exhibited higher strength and anti-dispersion. • DCP-rich CPCs increase the potential of bioresorption after reaction
Short Implants: New Horizon in Implant Dentistry.
Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan
2016-09-01
The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.
Directory of Open Access Journals (Sweden)
Sarah Hackman
2016-01-01
Full Text Available Malignant mesotheliomas are generally classified into epithelioid, sarcomatoid, desmoplastic, and biphasic types with rare reports of a small cell form. These small cell variants display some morphologic overlap with desmoplastic small round cell tumors (DSRCTs which generally occur within the abdominal cavity of young males and are defined by a characteristic t(11;22(p13;q12 translocation. However, there are rare reports of DSRCTs lacking this translocation. We present a 78-year-old man with a pleura-based biphasic neoplasm with features of both epithelioid mesothelioma and a small cell blastema-like neoplasm. The epithelioid portion showed IHC reactivity for pan cytokeratin, CK5/6, D2-40, and calretinin and the small cell portion marked with CD99, pan cytokeratin, WT1, FLI1, S100, CD200, MyoD1, and CD15. Fluorescence in situ hybridization testing for the t(11;22(p13;q12 translocation disclosed loss of the EWSR1 gene in 94% of tumor cell nuclei, but there was no evidence of the classic translocation. Array based-comparative genomic hybridization (a-CGH confirmed the tumor had numerous chromosome copy number losses, including 11p15.5-p11.12 and 22q12.1-q13.33, with loss of the EWSR1 and WT1 gene regions. Herein, we report novel complex CGH findings in a biphasic tumor and review the molecular genetic alterations in both mesothelioma and DSRCTs.
Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu
2016-01-01
Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.
Directory of Open Access Journals (Sweden)
Márcio Nunes Correa
2008-12-01
Full Text Available The aim of this paper was to describe the manifestation of developmental orthopedic diseases, particularly Osteochondritis Dissecans (OCD, in Crioulo foals, considering the clinical sings, radiological study and the animal’s diet. Were evaluated three foals from Crioulo breed presenting volume increase in the knee, fore fetlock and hind fetlock joints. The foals were submitted to radiological examination of the affected joints, showing irregular images in the growing plates region and radiolucent areas in the distal portion of the radius e first phalanx, characterizing the presence of degenerative lesions of the articular cartilage. The bromatological study of the pastures was made demonstrating imbalances in the calcium-phosphorus relation, being this one of the mains factors involved in the development of OCD lesions. The diagnosis was perform based on the clinical e radiological changes, besides the animal’s diet, age group and practiced exercise.
KEY WORDS: Crioulo, DOD, equine, osteochondritis dissecans, orthopedics. Este estudo teve como objetivo descrever a manifestação de distúrbios ortopédicos do desenvolvimento, particularmente a osteocondrite dissecante (OCD, em potros da raça Crioula, levando em consideração os sinais clínicos, estudo radiológico e a dieta dos animais. Avaliaram-se três potros da raça Crioula que apresentaram aumento de volume nas articulações radiocárpicas, metacarpofalangeanas e metatarsofalangeanas. Estes foram submetidos a exame radiológico das regiões afetadas, demonstrando áreas de irregularidade nas placas de crescimento e áreas radioluscentes na porção distal do rádio e primeira falange, caracterizando a presença de lesões degenerativas da cartilagem articular. Desenvolveu-se estudo bromatológico das pastagens, verificando-se desequilíbrios na relação cálcio–fósforo, sendo este um dos principais fatores envolvidos no desenvolvimento de lesões de OCD. O diagn
Ossification variants of the femoral condyles are not associated with osteochondritis dissecans
Energy Technology Data Exchange (ETDEWEB)
Jans, L., E-mail: lennartjans@hotmail.com [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Jaremko, J., E-mail: jjaremko@gmail.com [Department of Radiology, University of Alberta Hospital, 8440-112 Street, Edmonton T6G 2B7, Alberta (Canada); Ditchfield, M., E-mail: Michael.ditchfield@southernhealth.org.au [Department of Radiology, Monash University Clayton Campus, Wellington Road, Clayton 3800, VIC (Australia); De Coninck, T., E-mail: Tinekedeconinck@ugent.be [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Huysse, W., E-mail: Wouter.huysse@ugent.be [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium); Moon, A., E-mail: Anna.moon@rch.org.au [Department of Radiology, Royal Children' s Hospital, Flemington Road, Parkville 3052, VIC (Australia); Verstraete, K., E-mail: Koenraad.verstraete@ugent.be [Department of Radiology and Medical Imaging, Ghent University Hospital, De Pintelaan 185, 9000 Gent (Belgium)
2012-11-15
Purpose: To determine if ossification variants of the femoral condyles involving the subchondral bone plate are associated with osteochondritis dissecans (OCD). Materials and methods: The prevalence of ossification variants of the unaffected femoral condyle in 116 patients (aged 9-14 years) with unicondylar OCD on MRI (magnetic resonance imaging) of the knee was compared to a control group of 579 patients (aged 9-14 years) without OCD. The evolution of the ossification variants in both groups was studied by reviewing follow-up MR imaging side by side with the baseline study. Results: The prevalence of ossification variants in the unaffected condyle in patients with OCD (12.9%) and in the control group of patients without OCD (12.6%) was similar (p = 0.88). Evolution of ossification variants to OCD was not seen on follow-up MRI examinations. All variants had decreased in size or were no longer visible. Conclusion: Ossification variants of the femoral condyle that involve the subchondral bone plate are not associated with OCD. Clinical relevance statement: Ossification variants are not associated with OCD, indicating that routine MRI follow-up in affected children is not mandatory.
Ossification variants of the femoral condyles are not associated with osteochondritis dissecans
International Nuclear Information System (INIS)
Jans, L.; Jaremko, J.; Ditchfield, M.; De Coninck, T.; Huysse, W.; Moon, A.; Verstraete, K.
2012-01-01
Purpose: To determine if ossification variants of the femoral condyles involving the subchondral bone plate are associated with osteochondritis dissecans (OCD). Materials and methods: The prevalence of ossification variants of the unaffected femoral condyle in 116 patients (aged 9–14 years) with unicondylar OCD on MRI (magnetic resonance imaging) of the knee was compared to a control group of 579 patients (aged 9–14 years) without OCD. The evolution of the ossification variants in both groups was studied by reviewing follow-up MR imaging side by side with the baseline study. Results: The prevalence of ossification variants in the unaffected condyle in patients with OCD (12.9%) and in the control group of patients without OCD (12.6%) was similar (p = 0.88). Evolution of ossification variants to OCD was not seen on follow-up MRI examinations. All variants had decreased in size or were no longer visible. Conclusion: Ossification variants of the femoral condyle that involve the subchondral bone plate are not associated with OCD. Clinical relevance statement: Ossification variants are not associated with OCD, indicating that routine MRI follow-up in affected children is not mandatory.
Ryan, Alan J; Lackington, William A; Hibbitts, Alan J; Matheson, Austyn; Alekseeva, Tijna; Stejskalova, Anna; Roche, Phoebe; O'Brien, Fergal J
2017-12-01
Clinically available hollow nerve guidance conduits (NGCs) have had limited success in treating large peripheral nerve injuries. This study aims to develop a biphasic NGC combining a physicochemically optimized collagen outer conduit to bridge the transected nerve, and a neuroconductive hyaluronic acid-based luminal filler to support regeneration. The outer conduit is mechanically optimized by manipulating crosslinking and collagen density, allowing the engineering of a high wall permeability to mitigate the risk of neuroma formation, while also maintaining physiologically relevant stiffness and enzymatic degradation tuned to coincide with regeneration rates. Freeze-drying is used to seamlessly integrate the luminal filler into the conduit, creating a longitudinally aligned pore microarchitecture. The luminal stiffness is modulated to support Schwann cells, with laminin incorporation further enhancing bioactivity by improving cell attachment and metabolic activity. Additionally, this biphasic NGC is shown to support neurogenesis and gliogenesis of neural progenitor cells and axonal outgrowth from dorsal root ganglia. These findings highlight the paradigm that a successful NGC requires the concerted optimization of both a mechanical support phase capable of bridging a nerve defect and a neuroconductive phase with an architecture capable of supporting both Schwann cells and neurons in order to achieve functional regenerative outcome. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Energy Technology Data Exchange (ETDEWEB)
Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)
2016-10-15
We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Seyfoori, A., E-mail: klm.1985@yahoo.com [School of Metallurgy and Materials Engineering, Iran University of Science and Technology, 16846-13114 Tehran (Iran, Islamic Republic of); National Cell Bank, Pasteur Institute of Iran, 13164 Tehran (Iran, Islamic Republic of); Mirdamadi, Sh.; Seyedraoufi, Z.S.; Khavandi, A. [School of Metallurgy and Materials Engineering, Iran University of Science and Technology, 16846-13114 Tehran (Iran, Islamic Republic of); Aliofkhazraei, M. [Department of Materials Engineering, Faculty of Engineering, Tarbiat Modares University, 14115-143 Tehran (Iran, Islamic Republic of)
2013-10-01
The present research reports the synthesis of an innovative nanostructured composite film containing biphasic calcium phosphate (BCP) by the micro arc oxidation (MAO) method on AZ31 magnesium alloy. Nanometric structure of the used hydroxyapatite powder and the coatings were characterized by means of transmission and field-emission scanning electron microscope, respectively. Electrochemical behaviors of the pure MAO and nanocomposite films were also evaluated by electrochemical impedance spectroscopy and potentiodynamic polarization tests in simulated body fluid (SBF) environment. The results showed higher corrosion resistance of nanocomposite film compared to pure MAO coating, which was related to the blocking feature of the nanoparticles from the diffusing of the corrosive medium through the substrate. In addition, by immersing the specimens in simulated body fluid, greater apatite forming ability of the nanocomposite coating was proved. - Highlights: • Synthesis of innovative biphasic calcium phosphate containing nanostructured films via micro arc oxidation. • Nanocomposite film has lower degradation rate than pure MAO film. • Greater apatite forming ability for nanocomposite coating compared with pure MAO film is obtained.
Wang, Zhi-Kun; Shen, Xiao-Jun; Chen, Jun-Jie; Jiang, Ying-Qiu; Hu, Zhi-Yan; Wang, Xing; Liu, Li
2018-06-01
Herein, an efficient DES/MIBK biphasic pretreatment system for preparation of furfural and fermentable glucose from lignocellulose was developed with AlCl 3 as catalysis. The low-cost and renewable DES (Choline chloride-Oxalic acid) served not only as a Brønsted acid catalyst, but also as a pretreatment solvent in present work, and MIBK as an extracting reagent which can increase the yield of furfural in DES phase. The effects of this biphasic pretreatment on the furfural yield and saccharification of the lignocellulose before and after pretreatment were explored using HPLC, HAPEC, FT-IR, XRD and SEM. Under the best pretreatment condition (at 140 °C for 90 min), furfural could be obtained in 70.3% yield and 80.8% of the pretreated lignocellulose was saccharified, which was 8.4 times higher than that of the raw lignocellulose without pretreatment. In a word, this pretreatment system can be considered as a potential technique for efficient valorization of lignocellulose for production of furfural and fermentable glucose. Copyright © 2018. Published by Elsevier B.V.
International Nuclear Information System (INIS)
Seyfoori, A.; Mirdamadi, Sh.; Seyedraoufi, Z.S.; Khavandi, A.; Aliofkhazraei, M.
2013-01-01
The present research reports the synthesis of an innovative nanostructured composite film containing biphasic calcium phosphate (BCP) by the micro arc oxidation (MAO) method on AZ31 magnesium alloy. Nanometric structure of the used hydroxyapatite powder and the coatings were characterized by means of transmission and field-emission scanning electron microscope, respectively. Electrochemical behaviors of the pure MAO and nanocomposite films were also evaluated by electrochemical impedance spectroscopy and potentiodynamic polarization tests in simulated body fluid (SBF) environment. The results showed higher corrosion resistance of nanocomposite film compared to pure MAO coating, which was related to the blocking feature of the nanoparticles from the diffusing of the corrosive medium through the substrate. In addition, by immersing the specimens in simulated body fluid, greater apatite forming ability of the nanocomposite coating was proved. - Highlights: • Synthesis of innovative biphasic calcium phosphate containing nanostructured films via micro arc oxidation. • Nanocomposite film has lower degradation rate than pure MAO film. • Greater apatite forming ability for nanocomposite coating compared with pure MAO film is obtained
Vahabi, Zahra; Amirfattahi, Rasoul; Shayegh, Farzaneh; Ghassemi, Fahimeh
2015-09-01
Considerable efforts have been made in order to predict seizures. Among these methods, the ones that quantify synchronization between brain areas, are the most important methods. However, to date, a practically acceptable result has not been reported. In this paper, we use a synchronization measurement method that is derived according to the ability of bi-spectrum in determining the nonlinear properties of a system. In this method, first, temporal variation of the bi-spectrum of different channels of electro cardiography (ECoG) signals are obtained via an extended wavelet-based time-frequency analysis method; then, to compare different channels, the bi-phase correlation measure is introduced. Since, in this way, the temporal variation of the amount of nonlinear coupling between brain regions, which have not been considered yet, are taken into account, results are more reliable than the conventional phase-synchronization measures. It is shown that, for 21 patients of FSPEEG database, bi-phase correlation can discriminate the pre-ictal and ictal states, with very low false positive rates (FPRs) (average: 0.078/h) and high sensitivity (100%). However, the proposed seizure predictor still cannot significantly overcome the random predictor for all patients.
DEFF Research Database (Denmark)
Raina, Deepak Bushan; Isaksson, Hanna; Hettwer, Werner
2016-01-01
-the-shelf osteoinductive bone substitutes that can replace bone grafts are required. We tested the carrier properties of a biphasic, calcium sulphate and hydroxyapatite ceramic material, containing a combination of recombinant human bone morphogenic protein-2 (rhBMP-2) to induce bone, and zoledronic acid (ZA) to delay...
International Nuclear Information System (INIS)
Wiewiorski, M.; Miska, M.; Kretzschmar, M.; Studler, U.; Bieri, O.; Valderrabano, V.
2013-01-01
Aim: To assess cartilage quality using delayed gadolinium-enhanced magnetic resonance imaging after repair of osteochondral lesions of the talus using autologous matrix-induced chondrogenesis (AMIC). Materials and methods: A three-dimensional (3D) spoiled gradient-echo (SGE) sequence at 3 T was used to obtain quantitative T1 relaxation times before and after Gd-DTPA2 (Magnevist, 0.2 mM/kg bod weight) administration to assess 23 cases of AMIC-aided repair of osteochondral lesions of the talus. Delta relaxation rates (ΔR1) for reference cartilage (RC) and repair tissue (RT), and the relative delta relaxation rate (rΔR1) were calculated. The morphological appearance of the cartilage RT was graded on sagittal dual-echo steady-state (DESS) views according to the “magnetic resonance observation of cartilage repair tissue” (MOCART) protocol. The study was approved by the institutional review board and written consent from each patient was obtained. Results: The AMIC cases had a mean T1 relaxation time of 1.194 s (SD 0.207 s) in RC and 1.470 s (SD 0.384 s) in RT before contrast medium administration. The contrast-enhanced T1 relaxation time decreased to 0.480 s (SD 0.114 s) in RC and 0.411 s (SD 0.096 s) in RT. There was a significant difference (p > 0.05) between the ΔR1 in RC (1.372 × 10 −3 /s, range 0.526–3.201 × 10 −3 /s, SD 0.666 × 10 −3 /s) and RT (1.856 × 10 −3 /s, range 0.93–3.336 × 10 −3 /s, SD 0.609 × 10 −3 /s). The mean rΔR1 was 1.49, SD 0.45). The mean MOCART score at follow-up was 62.6 points (range 30–95, SD 15.3). Conclusion: The results of the present study suggest that repair cartilage resulting from AMIC-aided repair of osteochondral lesions of the talus has a significantly lower glycosaminoglycan (GAG) content than normal hyaline cartilage, but can be regarded as having hyaline-like properties
Acute Biphasic Effects of Ayahuasca.
Schenberg, Eduardo Ekman; Alexandre, João Felipe Morel; Filev, Renato; Cravo, Andre Mascioli; Sato, João Ricardo; Muthukumaraswamy, Suresh D; Yonamine, Maurício; Waguespack, Marian; Lomnicka, Izabela; Barker, Steven A; da Silveira, Dartiu Xavier
2015-01-01
Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG) recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8-13 Hz) after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30-50 and 50-100 Hz, respectively) between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca's chemical compounds, mostly N,N-dimethyltryptamine (DMT), harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered.
Acute Biphasic Effects of Ayahuasca.
Directory of Open Access Journals (Sweden)
Eduardo Ekman Schenberg
Full Text Available Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8-13 Hz after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30-50 and 50-100 Hz, respectively between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca's chemical compounds, mostly N,N-dimethyltryptamine (DMT, harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered.
Location of Osteochondritis Dissecans Lesions of the Capitellum.
Johnson, Christine C; Roberts, Susanne; Mintz, Douglas; Fabricant, Peter D; Hotchkiss, Robert N; Daluiski, Aaron
2018-04-17
The location of capitellar osteochondritis dissecans (OCD) lesions in the sagittal plane guides the surgical approach, and lesion location in the coronal plane influences surgical management. Although most lesions have been reported to occur between 4 o'clock and 4:30 (120° to 135° anterior to the humerus), some lesions are located elsewhere in the capitellum. The primary aim was to define the region of the capitellum affected by OCD lesions using a novel clock-face localization system. We reviewed 104 magnetic resonance imaging examinations diagnosing a nontraumatic capitellar OCD lesion. In the sagittal plane, lesion margins were recorded as degrees on the capitellum and converted into a clock-face format in which 0° corresponds to 12:00 with the forearm facing to the right. The 0° axis (12-o'clock axis) was defined as a line parallel to the anterior humeral line that intersects the capitellum center. The following coronal measurements were recorded: lesion width, capitellar width, and distance between the lateral capitellum and lateral lesion. Two independent observers took measurements. In the sagittal plane, average lesion location was 92° to 150° (3:04-5:00, clock face) and ranged from 52.1° to 249.5° (1:44-8:19, clock face). Average lesion dimensions were 10.7 mm (mediolateral width) and 5.2 mm (anteroposterior depth). Interrater reliability was high (intraclass correlation coefficient = 0.98). Using a magnetic resonance imaging-based clock-face localization system, we found that capitellar OCD lesions affect a broad region of the capitellum in the sagittal plane. The clock-face localization system allows for precise description of capitellar OCD lesion location, which may facilitate intraoperative decision and longitudinal monitoring. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Walcott, Gregory P; Melnick, Sharon B; Killingsworth, Cheryl R; Ideker, Raymond E
2010-01-01
Since the initial development of the defibrillator, there has been concern that, while delivery of a large electric shock would stop fibrillation, it would also cause damage to the heart. This concern has been raised again with the development of the biphasic defibrillator. To compare defibrillation efficacy, postshock cardiac function, and troponin I levels following 150-J and 360-J shocks. Nineteen swine were anesthetized with isoflurane and instrumented with pressure catheters in the left ventricle, aorta, and right atrium. The animals were fibrillated for 6 minutes, followed by defibrillation with either low-energy (n = 8) or high-energy (n = 11) shocks. After defibrillation, chest compressions were initiated and continued until return of spontaneous circulation (ROSC). Epinephrine, 0.01 mg/kg every 3 minutes, was given for arterial blood pressure < 50 mmHg. Hemodynamic parameters were recorded for four hours. Transthoracic echocardiography was performed and troponin I levels were measured at baseline and four hours following ventricular fibrillation (VF). Survival rates at four hours were not different between the two groups (low-energy, 5 of 8; high-energy, 7 of 11). Results for arterial blood pressure, positive dP/dt (first derivative of pressure measured over time, a measure of left ventricular contractility), and negative dP/dt at the time of lowest arterial blood pressure (ABP) following ROSC were not different between the two groups (p = not significant [NS]), but were lower than at baseline. All hemodynamic measures returned to baseline by four hours. Ejection fractions, stroke volumes, and cardiac outputs were not different between the two groups at four hours. Troponin I levels at four hours were not different between the two groups (12 +/- 11 ng/mL versus 21 +/- 26 ng/mL, p = NS) but were higher at four hours than at baseline (19 +/- 19 ng/mL versus 0.8 +/- 0.5 ng/mL, p < 0.05, groups combined). Biphasic 360-J shocks do not cause more cardiac damage
Energy Technology Data Exchange (ETDEWEB)
El Kammouni, Rhimou, E-mail: elkammounirhimou@gmail.com [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Vázquez, Manuel [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Lezama, Luis [Depto. Química Inorgánica, Universidad País Vasco, UPV/EHU, Bilbao (Spain); Kurlyandskaya, Galina [Depto. Electricidad y Electrónica, Universidad País Vasco, UPV/EHU, Bilbao (Spain); Dept. Magnetism and Magnetic Nanomaterials, Ural Federal University, Ekaterinburg (Russian Federation); Kraus, Ludek [Institute of Physics, Academy of Sciences of the Czech Republic, Prague (Czech Republic)
2014-11-15
The microwave absorption phenomena of single and biphase magnetic microwires with soft magnetic behavior have been investigated as a function of DC applied magnetic field using two alternative techniques: (i) absorption measurements in the temperature range of 4–300 K using a spectrometer operating at X-band frequency, at 9.5 GHz, and (ii) room-temperature, RT, ferromagnetic resonance measurements in a network analyzer in the frequency range up to 20 GHz. Complementary low-frequency magnetic characterization was performed in a Vibrating Sample Magnetometer. Studies have been performed for 8 μm diameter small-magnetostriction amorphous CoFeSiB single-phase microwire, coated by micrometric Pyrex layer, and after electroplating an external shell, 2 µm or 4 µm thick, of FeNi alloys. For single phase CoFeSiB microwire, a single absorption is observed, whose DC field dependence of resonance frequency at RT fits to a Kittel-law behavior for in-plane magnetized thin film. The temperature dependence behavior shows a monotonic increase in the resonance field, H{sub r}, with temperature. A parallel reduction of the circular anisotropy field, H{sub K}, is deduced from the temperature dependence of hysteresis loops. For biphase, CoFeSiB/FeNi, microwires, the absorption phenomena at RT also follow the Kittel condition. The observed opposite evolution with temperature of resonance field, H{sub r}, in 2 and 4 µm thick FeNi samples is interpreted considering the opposite sign of magnetostriction of the respective FeNi layers. The stress-induced magnetic anisotropy field, H{sub K}, in the FeNi shell is deduced to change sign at around 130 K. - Highlights: • A single absorption phenomenon is observed for single phase CoFeSiB. • The T dependence of the microwave behavior shows a monotonic increase of H{sub r} with T. • The absorption at RT follows the Kittel condition for biphase CoFe/FeNi microwires. • The T dependence of resonant field of CoFe/FeNi is interpreted to be
Directory of Open Access Journals (Sweden)
Carole Chakar
2014-01-01
Full Text Available Bone substitutes alone or supplemented with platelet-derived concentrates are widely used to promote bone regeneration but their potency remains controversial. The aim of this study was, therefore, to compare the regenerative potential of preparations containing autologous platelet lysate (APL and particles of either deproteinized bovine bone mineral (DBBM or biphasic calcium phosphate (BCP, two bone substitutes with different resorption patterns. Rabbit APL was prepared by freeze-thawing a platelet suspension. Critical-size defects in rabbit femoral condyle were filled with DBBM or DBBM+APL and BCP or BCP+APL. Rabbits were sacrificed after six weeks and newly formed bone and residual implanted material were evaluated using nondemineralized histology and histomorphometry. New bone was observed around particles of all fillers tested. In the defects filled with BCP, the newly formed bone area was greater (70%; P<0.001 while the residual material area was lower (60%; P<0.001 than that observed in those filled with DBBM. New bone and residual material area of defects filled with either APL+DBBM or APL+BCP were similar to those observed in those filled with the material alone. In summary, osteoconductivity and resorption of BCP were greater than those of DBBM, while APL associated with either DBBM or BCP did not have an additional benefit.
International Nuclear Information System (INIS)
Peiss, J.; Adam, G.; Casser, R.; Urhahn, R.; Guenther, R.W.
1995-01-01
Magnetic resonance imaging (MRI) was performed on seven patients with aseptic osteonecrosis (n=4) and osteochondritis dissecans (OCD; n=3) of the elbow. Precontrast MRI was superior to plain radiographs, which did not show any abnormality in three cases of osteonecrosis. On gadopentetate-dimeglumine-enhanced T1-weighted images, which were obtained in three patients with osteonecrosis and three patients with OCD, all cases of osteonecrosis demonstrated homogeneous enhancement of the lesions. All cases of OCD were diagnosed on plain radiographs. On MRI one showed significant enhancement of the loose body. In another case an incompletely enhancing loose body was surrounded by a diffusely enhancing region. In the third patient only a small marginal enhancement of the defect was observed. Our results suggest that MRI can improve the accuracy in diagnosis of aseptic osteonecrosis of the elbow. The use of gadopentetate dimeglumine allows the viability of the lesions or the loose bodies to be demonstrated and reparative tissue to be detected. (orig.)
Work Stress and Alcohol Use: Developing and Testing a Biphasic Self-Medication Model
Frone, Michael R.
2016-01-01
This study developed and tested a moderated-mediation model of work stress and alcohol use, based on the biphasic (stimulant and sedative) effects of alcohol and the self-medication and stress-vulnerability models of alcohol use. The model proposes that exposure to work stressors can increase both negative affect and work fatigue, and that these two sources of strain can subsequently motivate the use of alcohol. However, the relations of negative affect and work fatigue to a...
Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn
S. N. Koval; A. Ye. Kulagin
2006-01-01
Biphasic positive airway pressure (BIPAP) (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP) is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency) is calculated ...
Oladeji, Lasun O; Stannard, James P; Cook, Cristi R; Kfuri, Mauricio; Crist, Brett D; Smith, Matthew J; Cook, James L
2017-10-01
Transplantation of fresh osteochondral allografts (OCAs) is an attractive treatment option for symptomatic articular cartilage lesions in young, healthy patients. Because the lack of OCA bone integration can be a cause of treatment failure, methods for speeding and enhancing OCA bone integration to mitigate this potential complication are highly desirable. To determine if autogenous bone marrow aspirate concentrate (BMC) treatment of large femoral condylar OCAs would be associated with superior radiographic OCA bone integration compared with nontreated allografts during the critical first 6 months after surgery. Cohort study; Level of evidence, 3. A review of patients enrolled in a prospective registry who were treated with transplantation of large OCAs to one or both femoral condyles at our institution from March 12, 2013 to March 14, 2016 was performed. Patients were stratified into 2 groups based on BMC treatment versus no BMC treatment; the treatment was nonrandomized and was rooted in a shift in practice and a continuing effort to optimize OCA transplantation at our institution. Patients were excluded if they did not have orthogonal view radiographs performed at 6 weeks, 3 months, and 6 months postoperatively. Each condyle undergoing OCA transplantation was assessed individually by an independent musculoskeletal radiologist, who was blinded to the treatment group and time point. OCAs were assessed with respect to graft integration (0%-100%; 0 = no integration, 100 = complete integration) and degree of sclerosis (0-3; 0 = normal, 1 = mild sclerosis, 2 = moderate sclerosis, and 3 = severe sclerosis) of the graft at each time point. This study identified 17 condyles in 15 patients who underwent OCA transplantation without BMC and 29 condyles in 22 patients who underwent OCA transplantation with BMC. The BMC group had significantly ( P = .033) higher graft integration scores at 6 weeks, 3 months, and 6 months after surgery. Graft sclerosis was significantly ( P
International Nuclear Information System (INIS)
Dearnaley, Geoffrey
1975-01-01
First, ion implantation in semiconductors is discussed: ion penetration, annealing of damage, gettering, ion implanted semiconductor devices, equipement requirements for ion implantation. The importance of channeling for ion implantation is studied. Then, some applications of ion implantation in metals are presented: study of the corrosion of metals and alloys; influence or ion implantation on the surface-friction and wear properties of metals; hyperfine interactions in implanted metals
International Nuclear Information System (INIS)
De Lange, E.E.; Shaffer, H.A. Jr.; Riddervold, H.O.
1987-01-01
The authors performed a prospective study to determine the value of selective use of the biphasic contrast technique for a variety of indications. In a series of 571 double-contrast barium enema examinations, the examination was immediately followed by a single-contrast study in 85 cases. The biphasic procedure was performed to reexamine a colonic segment that was poorly evaluated initially because of diverticulosis (eta = 35), incomplete filling (eta = 28), or poor mucosal coating (eta = 26); or to verify or exclude a possible lesion identified during the double-contrast examination (eta = 22). The single-contrast study confirmed five polyps and excluded lesions in 17 cases with suspected polyps (eta = 5), strictures (eta = 4), and spasm (eta = 8). Six polyps not visualized on the double-contrast examination were detected with the single-contrast procedure
Wang, Wenju; Ren, Junli; Li, Huiling; Deng, Aojie; Sun, Runcang
2015-05-01
Direct catalytic transformation of xylan-type hemicelluloses to furfural in the aqueous system and the biphasic system were comparatively investigated under mild conditions. Screening of several promising chlorides for conversion of beech xylan in the aqueous system revealed the Lewis acid SnCl4 was the most effective catalyst. Comparing to the single aqueous system, the bio-based 2-methyltetrahydrofuran (2-MTHF)/H2O biphasic system was more conducive to the synthesis of furfural, in which the highest furfural yield of 78.1% was achieved by using SnCl4 as catalysts under the optimized reaction conditions (150°C, 120 min). Additionally, the influences of xylan-type hemicelluloses with different chemical and structural features from beech, corncob and bagasse on the furfural production were studied. It was found that furfural yield to some extent was determined by the xylose content in hemicelluloses and also had relationships with the molecular weight of hemicelluloses and the degree of crystallization. Copyright © 2015 Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Kerimaa, Pekka; Ojala, Risto; Markkanen, Paula; Tervonen, Osmo; Blanco Sequeiros, Roberto; Sinikumpu, Juha-Jaakko; Korhonen, Jussi; Hyvoenen, Pekka
2014-01-01
The purpose of this study was to evaluate the feasibility of MRI guidance for percutaneous retrograde drilling in the treatment of osteochondritis dissecans of the talus (OCDT). Four patients, one juvenile and three adults, with one OCDT lesion each and persisting ankle pain after conservative treatment, were treated with MRI-guided retrograde drilling. All lesions were stable and located in the middle or posterior medial third of the talar dome. Pain relief and the ability to return to normal activities were assessed during clinical follow-up. MRI and plain film radiographs were used for imaging follow-up. Technical success was 100 % with no complications and with no damage to the overlying cartilage. All patients experienced some clinical benefit, although only one had complete resolution of pain and one had a relapse leading to surgical treatment. Changes in the pathological imaging findings were mostly very slight during the follow-up period. MRI guidance seems accurate, safe and technically feasible for retrograde drilling of OCDT. Larger series are needed to reliably assess its clinical value. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Kerimaa, Pekka; Ojala, Risto; Markkanen, Paula; Tervonen, Osmo; Blanco Sequeiros, Roberto [Oulu University Hospital, Department of Radiology, Oulu (Finland); Sinikumpu, Juha-Jaakko; Korhonen, Jussi [Oulu University Hospital, Department of Paediatric Surgery, Oulu (Finland); Hyvoenen, Pekka [Oulu University Hospital, Department of Surgery, Oulu (Finland)
2014-07-15
The purpose of this study was to evaluate the feasibility of MRI guidance for percutaneous retrograde drilling in the treatment of osteochondritis dissecans of the talus (OCDT). Four patients, one juvenile and three adults, with one OCDT lesion each and persisting ankle pain after conservative treatment, were treated with MRI-guided retrograde drilling. All lesions were stable and located in the middle or posterior medial third of the talar dome. Pain relief and the ability to return to normal activities were assessed during clinical follow-up. MRI and plain film radiographs were used for imaging follow-up. Technical success was 100 % with no complications and with no damage to the overlying cartilage. All patients experienced some clinical benefit, although only one had complete resolution of pain and one had a relapse leading to surgical treatment. Changes in the pathological imaging findings were mostly very slight during the follow-up period. MRI guidance seems accurate, safe and technically feasible for retrograde drilling of OCDT. Larger series are needed to reliably assess its clinical value. (orig.)
Progranulin haploinsufficiency causes biphasic social dominance abnormalities in the tube test.
Arrant, A E; Filiano, A J; Warmus, B A; Hall, A M; Roberson, E D
2016-07-01
Loss-of-function mutations in progranulin (GRN) are a major autosomal dominant cause of frontotemporal dementia (FTD), a neurodegenerative disorder in which social behavior is disrupted. Progranulin-insufficient mice, both Grn(+/-) and Grn(-/-) , are used as models of FTD due to GRN mutations, with Grn(+/-) mice mimicking the progranulin haploinsufficiency of FTD patients with GRN mutations. Grn(+/-) mice have increased social dominance in the tube test at 6 months of age, although this phenotype has not been reported in Grn(-/-) mice. In this study, we investigated how the tube test phenotype of progranulin-insufficient mice changes with age, determined its robustness under several testing conditions, and explored the associated cellular mechanisms. We observed biphasic social dominance abnormalities in Grn(+/-) mice: at 6-8 months, Grn(+/-) mice were more dominant than wild-type littermates, while after 9 months of age, Grn(+/-) mice were less dominant. In contrast, Grn(-/-) mice did not exhibit abnormal social dominance, suggesting that progranulin haploinsufficiency has distinct effects from complete progranulin deficiency. The biphasic tube test phenotype of Grn(+/-) mice was associated with abnormal cellular signaling and neuronal morphology in the amygdala and prefrontal cortex. At 6-9 months, Grn(+/-) mice exhibited increased mTORC2/Akt signaling in the amygdala and enhanced dendritic arbors in the basomedial amygdala, and at 9-16 months Grn(+/-) mice exhibited diminished basal dendritic arbors in the prelimbic cortex. These data show a progressive change in tube test dominance in Grn(+/-) mice and highlight potential underlying mechanisms by which progranulin insufficiency may disrupt social behavior. © 2016 John Wiley & Sons Ltd and International Behavioural and Neural Genetics Society.
Magnetic resonance imaging in the evaluation of osteochondritis dissecans of the patella
International Nuclear Information System (INIS)
Choi, Yun Sun; Cohen, Noah A.; Potter, Hollis G.; Mintz, Douglas N.
2007-01-01
The objective was to evaluate the magnetic resonance (MR) appearance of patellar osteochondritis dissecans (OCD). We retrospectively analyzed MR images of 16 patients (18 cases, mean age 20 years) using OCD of the patella. In 5 cases surgery was carried out, and we compared the surgical findings with the MR imaging findings in these cases. In all 18 cases, OCD was located central-inferiorly on the patella, and the average size was 11 x 11 x 7 mm. Subchondral deformities were present in 16 out of 18 cases (88.9%), subchondral cyst formation in 4 cases (22.2%), reactive bone marrow signal in 8 cases (44.4%), overlying patellar cartilage abnormality in 14 cases (77.8%), loose body in 2 cases (11.1%), patella alta in 8 cases (44.4%), hypoplastic sulcus in 7 cases (38.9%), and synovitis in 4 cases (22.2%). In all 5 cases in which surgery was carried out, the cartilage abnormality classified on the MR images was confirmed, and a loose body was removed at arthroscopy in 2 of the 5 cases. Magnetic resonance imaging of patellar OCD typically shows subchondral deformity and variable abnormalities of the overlying patellar cartilage located central-inferiorly on the patella. (orig.)
Osteochondral lesions in developing rats intoxicated with thallium twenty four hours after birth.
Barroso-Moguel, R; Villeda-Hernández, J; Méndez-Armenta, M; Ríos, C; Galván-Arzate, S
1992-01-01
An i.p. injection of a solution of thallium acetate in deionized water at a dose of 32 mg/kg, in 24-h-old rats, produces morphological and biochemical alterations in both cartilaginous and osseous tissues. From the beginning, there are alterations in the cartilaginous cell as well as in chrondrine, osteoblasts, osseous tissue and bone marrow. Rats were sacrificed at 24, 48, and 72 h and also at 7 days. Two animals survived for 50 days. One showed total irreversible alopecia while the other one had partial alopecia with discrete recovery. Both showed a low weight and a size of 8 cm. Microscopically, degenerative changes were produced consisting of alteration and death of many cartilaginous cells, uneven metachromasia and the chondrine and decrease of the growth cartilage, scanty bone trabeculae with few osteoblasts. The bone marrow showed few myeloblasts and megakaryocytes. Progressive cellular damage throughout the 50 days of survival represents a response of the thallium ionic accumulation and recycling in cellular mitochondria of all the body's cells. This appeared in our study as irreversible and progressive osteochondral alterations with atrophy of the skin and its adnexa, hyalinization of elastic and collagenous fibers with intense interstitial edema.
Directory of Open Access Journals (Sweden)
Robert D Prinz
Full Text Available The glycosaminoglycan chondroitin sulfate is a critical component of proteoglycans on the cell surface and in the extracellular matrix. As such, chondroitin sulfate side chains and the sulfation balance of chondroitin play important roles in the control of signaling pathways, and have a functional importance in human disease. In contrast, very little is known about the roles of chondroitin sulfate molecules and sulfation patterns during mammalian development and cell lineage specification. Here, we report a novel biphasic role of chondroitin sulfate in the specification of the cardiac cell lineage during embryonic stem cell differentiation through modulation of Wnt/beta-catenin signaling. Lineage marker analysis demonstrates that enzymatic elimination of endogenous chondroitin sulfates leads to defects specifically in cardiac differentiation. This is accompanied by a reduction in the number of beating cardiac foci. Mechanistically, we show that endogenous chondroitin sulfate controls cardiac differentiation in a temporal biphasic manner through inhibition of the Wnt/beta-catenin pathway, a known regulatory pathway for the cardiac lineage. Treatment with a specific exogenous chondroitin sulfate, CS-E, could mimic these biphasic effects on cardiac differentiation and Wnt/beta-catenin signaling. These results establish chondroitin sulfate and its sulfation balance as important regulators of cardiac cell lineage decisions through control of the Wnt/beta-catenin pathway. Our work suggests that targeting the chondroitin biosynthesis and sulfation machinery is a novel promising avenue in regenerative strategies after heart injury.
Prinz, Robert D; Willis, Catherine M; van Kuppevelt, Toin H; Klüppel, Michael
2014-01-01
The glycosaminoglycan chondroitin sulfate is a critical component of proteoglycans on the cell surface and in the extracellular matrix. As such, chondroitin sulfate side chains and the sulfation balance of chondroitin play important roles in the control of signaling pathways, and have a functional importance in human disease. In contrast, very little is known about the roles of chondroitin sulfate molecules and sulfation patterns during mammalian development and cell lineage specification. Here, we report a novel biphasic role of chondroitin sulfate in the specification of the cardiac cell lineage during embryonic stem cell differentiation through modulation of Wnt/beta-catenin signaling. Lineage marker analysis demonstrates that enzymatic elimination of endogenous chondroitin sulfates leads to defects specifically in cardiac differentiation. This is accompanied by a reduction in the number of beating cardiac foci. Mechanistically, we show that endogenous chondroitin sulfate controls cardiac differentiation in a temporal biphasic manner through inhibition of the Wnt/beta-catenin pathway, a known regulatory pathway for the cardiac lineage. Treatment with a specific exogenous chondroitin sulfate, CS-E, could mimic these biphasic effects on cardiac differentiation and Wnt/beta-catenin signaling. These results establish chondroitin sulfate and its sulfation balance as important regulators of cardiac cell lineage decisions through control of the Wnt/beta-catenin pathway. Our work suggests that targeting the chondroitin biosynthesis and sulfation machinery is a novel promising avenue in regenerative strategies after heart injury.
Biphasic electrical targeting plays a significant role in schwann cell activation.
Kim, In Sook; Song, Yun Mi; Cho, Tae Hyung; Pan, Hui; Lee, Tae Hyung; Kim, Sung June; Hwang, Soon Jung
2011-05-01
Electrical stimulation (ES) is a promising technique for axonal regeneration of peripheral nerve injuries. However, long-term, continuous ES in the form of biphasic electric current (BEC) to stimulate axonal regeneration has rarely been attempted and the effects of BEC on Schwann cells are unknown. We hypothesized that long-term, continuous ES would trigger the activation of Schwann cells, and we therefore investigated the effect of BEC on the functional differentiation of primary human mesenchymal stromal cells (hMSCs) into Schwann cells, as well as the activity of primary Schwann cells. Differentiation of hMSCs into Schwann cells was determined by coculture with rat pheochromocytoma cells (PC12 cell line). We also investigated the in vivo effects of long-term ES (4 weeks) on axonal outgrowth of a severed sciatic nerve with a 7-mm gap after retraction of the nerve ends in rats by implanting an electronic device to serve as a neural conduit. PC12 cells cocultured with hMSCs electrically stimulated during culture in Schwann cell differentiation medium (Group I) had longer neurites and a greater percentage of PC12 cells were neurite-sprouting than when cocultured with hMSCs cultured in growth medium (control group) or unstimulated hMSCs in the same culture conditions as used for Group I (Group II). Group I cells showed significant upregulation of Schwann cell-related neurotrophic factors such as nerve growth factor and glial-derived neurotrophic factor compared to Group II cells at both the mRNA and protein levels. Primary Schwann cells responded to continuous BEC with increased proliferation and the induction of nerve growth factor and glial-derived neurotrophic factor, similar to Group I cells, and in addition, induction of brain-derived neurotrophic factor was observed. Immunohistochemical investigation of sciatic nerve regenerates revealed that BEC increased axonal outgrowth significantly. These results demonstrate that BEC enhanced the functional activity of
[Current overview of cartilage regeneration procedures].
Schenker, H; Wild, M; Rath, B; Tingart, M; Driessen, A; Quack, V; Betsch, M
2017-11-01
Cartilage is an avascular, alymphatic and non-innervated tissue with limited intrinsic repair potential. The high prevalence of cartilage defects and their tremendous clinical importance are a challenge for all treating physicians. This article provides the reader with an overview about current cartilage treatment options and their clinical outcome. Microfracture is still considered the gold standard in the treatment of small cartilage lesions. Small osteochondral defects can be effectively treated with the autologous osteochondral transplantation system. Larger cartilage defects are successfully treated by autologous membrane-induced chondrogenesis (AMIC) or by membrane-assisted autologous chondrocyte implantation (MACI). Despite limitations of current cartilage repair strategies, such procedures can result in short- and mid-term clinical improvement of the patients. Further developments and clinical studies are necessary to improve the long-term outcome following cartilage repair.
Short dental implants: an emerging concept in implant treatment.
Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah
2014-06-01
Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.
Number of implants for mandibular implant overdentures: a systematic review
Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross
2012-01-01
PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572
Directory of Open Access Journals (Sweden)
NL Davison
2015-06-01
Full Text Available It has been reported that surface microstructural dimensions can influence the osteoinductivity of calcium phosphates (CaPs, and osteoclasts may play a role in this process. We hypothesised that surface structural dimensions of ≤ 1 μm trigger osteoinduction and osteoclast formation irrespective of macrostructure (e.g., concavities, interconnected macropores, interparticle space or surface chemistry. To test this, planar discs made of biphasic calcium phosphate (BCP: 80 % hydroxyapatite, 20 % tricalcium phosphate were prepared with different surface structural dimensions – either ~ 1 μm (BCP1150 or ~ 2-4 μm (BCP1300 – and no macropores or concavities. A third material was made by sputter coating BCP1150 with titanium (BCP1150Ti, thereby changing its surface chemistry but preserving its surface structure and chemical reactivity. After intramuscular implantation in 5 dogs for 12 weeks, BCP1150 formed ectopic bone in 4 out of 5 samples, BCP1150Ti formed ectopic bone in 3 out of 5 samples, and BCP1300 formed no ectopic bone in any of the 5 samples. In vivo, large multinucleated osteoclast-like cells densely colonised BCP1150, smaller osteoclast-like cells formed on BCP1150Ti, and osteoclast-like cells scarcely formed on BCP1300. In vitro, RAW264.7 cells cultured on the surface of BCP1150 and BCP1150Ti in the presence of osteoclast differentiation factor RANKL (receptor activator for NF-κB ligand proliferated then differentiated into multinucleated osteoclast-like cells with positive tartrate resistant acid phosphatase (TRAP activity. However, cell proliferation, fusion, and TRAP activity were all significantly inhibited on BCP1300. These results indicate that of the material parameters tested – namely, surface microstructure, macrostructure, and surface chemistry – microstructural dimensions are critical in promoting osteoclastogenesis and triggering ectopic bone formation.
Development of Modified-Release Tablets of Zolpidem Tartrate by Biphasic Quick/Slow Delivery System
Mahapatra, Anjan Kumar; Sameeraja, N. H.; Murthy, P. N.
2014-01-01
Zolpidem tartrate is a non-benzodiazepine analogue of imidazopyridine of sedative and hypnotic category. It has a short half-life with usual dosage regimen being 5 mg, two times a day, or 10 mg, once daily. The duration of action is considered too short in certain circumstances. Thus, it is desirable to lengthen the duration of action. The formulation design was implemented by preparing extended-release tablets of zolpidem tartrate using the biphasic delivery system technology, where sodium s...
Stockmann, T. Jane; Zhang, Jing; Montgomery, Anne-Marie; Ding, Zhifeng
2014-01-01
A room temperature ionic liquid (IL) composed of a quaternary alkylphosphonium (trihexyltetradecylphosphonium, P66614(+)) and tetrakis(pentafluorophenyl) borate anion (TB) was employed within a water| P66614TB (w|P66614TB or w|IL) biphasic system to evaluate cesium ion extraction in comparison to that with a traditional water|organic solvent (w|o) combination. Cs-137 is a major contributor to the radioactivity of spent nuclear fuel as it leaves the reactor, and its extraction efficiency is th...
Primary prevention of peri-implantitis: managing peri-implant mucositis.
Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U
2015-04-01
Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention
Méthot, Stéphane; Changoor, Adele; Tran-Khanh, Nicolas; Hoemann, Caroline D.; Stanish, William D.; Restrepo, Alberto; Shive, Matthew S.; Buschmann, Michael D.
2016-01-01
Objective The efficacy and safety of BST-CarGel, a chitosan-based medical device for cartilage repair, was compared with microfracture alone at 1 year during a multicenter randomized controlled trial (RCT) in the knee. The quality of repair tissue of osteochondral biopsies collected from a subset of patients was compared using blinded histological assessments. Methods The international RCT evaluated repair tissue quantity and quality by 3-dimensional quantitative magnetic resonance imaging as co-primary endpoints at 12 months. At an average of 13 months posttreatment, 21/41 BST-CarGel and 17/39 microfracture patients underwent elective second look arthroscopies as a tertiary endpoint, during which ICRS (International Cartilage Repair Society) macroscopic scoring was carried out, and osteochondral biopsies were collected. Stained histological sections were evaluated by blinded readers using ICRS I and II histological scoring systems. Collagen organization was evaluated using a polarized light microscopy score. Results BST-CarGel treatment resulted in significantly better ICRS macroscopic scores (P = 0.0002) compared with microfracture alone, indicating better filling, integration, and tissue appearance. Histologically, BST-CarGel resulted in a significant improvement of structural parameters—Surface Architecture (P = 0.007) and Surface/Superficial Assessment (P = 0.042)—as well as cellular parameters—Cell Viability (P = 0.006) and Cell Distribution (P = 0.032). No histological parameters were significantly better for the microfracture group. BST-CarGel treatment also resulted in a more organized repair tissue with collagen stratification more similar to native hyaline cartilage, as measured by polarized light microscopy scoring (P = 0.0003). Conclusion Multiple and independent analyses in this biopsy substudy demonstrated that BST-CarGel treatment results in improved structural and cellular characteristics of repair tissue at 1 year posttreatment compared with
Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection
DEFF Research Database (Denmark)
Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning
2017-01-01
OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search...... of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...
CSIR Research Space (South Africa)
Ripamonti, U
2008-01-01
Full Text Available Long-term studies in the non-human primate Chacma baboon Papio ursinus were set to investigate the induction of bone formation by biphasic hydroxyapatite/β-tricalcium phosphate (HA/β-TCP) biomimetic matrices. HA/β-TCP biomimetic matrices in a pre...
Energy Technology Data Exchange (ETDEWEB)
Mohamed, Khaled R., E-mail: Kh_rezk966@yahoo.com [Biomaterials Department, National Research Centre, Dokki, Cairo (Egypt); Mousa, Sahar M. [Chemistry Department, Science and Art College, King Abdulaziz University, Rabigh Campus, P.O. Box 344, 21911 Rabigh (Saudi Arabia); Inorganic Chemistry Department, National Research Centre, Dokki, P.O. Box 12622, 11787 Cairo (Egypt); El Bassyouni, Gehan T. [Biomaterials Department, National Research Centre, Dokki, Cairo (Egypt); Medical Physics Department, College of Medicine, Taif University (Saudi Arabia)
2014-02-01
Graphical abstract: (a) Schema of the process, (b) TEM of nano particles of biphasic materials and (c) SEM of post-immersion. - Highlights: • Ratio of HA and β-TCP phases were controlled by thermal treatment. • HA partially decomposed into β-TCP with other bioactive phases. • Calcined HA at 900 °C is the best for the bioactivity behavior. - Abstract: In this study, a novel process of preparing biphasic calcium phosphate (BCP) is proposed. Also its bioactivity for the utilization of the prepared BCP as a biomaterial is studied. A mixture of calcium hydroxyapatite (HAP) and tricalcium phosphate (β-TCP) could be obtained by thermal treatment of HAP which was previously prepared from phosphogypsum (PG) waste. The chemical and phase composition, morphology and particle size of prepared samples was characterized by X-ray diffraction (XRD), Infrared spectroscopy (IR), Scanning electron microscopy (SEM) and Transmission electron microscopy (TEM). The bioactivity was investigated by soaking of the calcined samples in simulated body fluid (SBF). Results confirmed that the calcination temperatures played an important role in the formation of calcium phosphate (CP) materials. XRD results indicated that HAP was partially decomposed into β-TCP. The in vitro data confirmed that the calcined HAP forming BCP besides other phases such as pyrophosphate and silica are bioactive materials. Therefore, BCP will be used as good biomaterials for medical applications.
Directory of Open Access Journals (Sweden)
Keun-A Chang
2011-04-01
Full Text Available The use of non-chemical methods to differentiate stem cells has attracted researchers from multiple disciplines, including the engineering and the biomedical fields. No doubt, growth factor based methods are still the most dominant of achieving some level of proliferation and differentiation control--however, chemical based methods are still limited by the quality, source, and amount of the utilized reagents. Well-defined non-chemical methods to differentiate stem cells allow stem cell scientists to control stem cell biology by precisely administering the pre-defined parameters, whether they are structural cues, substrate stiffness, or in the form of current flow. We have developed a culture system that allows normal stem cell growth and the option of applying continuous and defined levels of electric current to alter the cell biology of growing cells. This biphasic current stimulator chip employing ITO electrodes generates both positive and negative currents in the same culture chamber without affecting surface chemistry. We found that biphasic electrical currents (BECs significantly increased the proliferation of fetal neural stem cells (NSCs. Furthermore, BECs also promoted the differentiation of fetal NSCs into neuronal cells, as assessed using immunocytochemistry. Our results clearly show that BECs promote both the proliferation and neuronal differentiation of fetal NSCs. It may apply to the development of strategies that employ NSCs in the treatment of various neurodegenerative diseases, such as Alzheimer's and Parkinson's diseases.
Qing, Qing; Guo, Qi; Zhou, Linlin; Wan, Yilun; Xu, Youqing; Ji, Huilong; Gao, Xiaohang; Zhang, Yue
2017-02-01
Catalytic conversion of corncob pretreatment hydrolysate and raw corncob into furfural in a modified biphasic system by SO 4 2- /SnO 2 - MMT solid catalyst has been developed. The influence of the organic solvent type, organic to water phase ratio, sodium chloride concentration, reaction temperature and time on the furfural production were comparatively evaluated. The results showed that furfural yields of 81.7% and 66.1% were achieved at 190°C for 15mins and 190°C for 20mins, respectively, for corncob pretreatment hydrolysate and raw corncob by this solid catalyst. The solid catalyst used in this study exhibited good stability and high efficiency applied in the modified biphasic system in addition to excellent recyclability. The proposed catalytic system displayed high performance for catalytic conversion of lignocellulosic biomass into important platform chemicals and has great potential in industrial application. Copyright © 2016 Elsevier Ltd. All rights reserved.
Calado, Ricardo; Leal, Miguel Costa
2015-01-01
The study of trophic ecology of benthic marine invertebrates with bi-phasic life cycles is critical to understand the mechanisms shaping population dynamics. Moreover, global climate change is impacting the marine environment at an unprecedented level, which promotes trophic mismatches that affect the phenology of these species and, ultimately, act as drivers of ecological and evolutionary change. Assessing the trophic ecology of marine invertebrates is critical to understanding maternal investment, larval survival to metamorphosis, post-metamorphic performance, resource partitioning and trophic cascades. Tools already available to assess the trophic ecology of marine invertebrates, including visual observation, gut content analysis, food concentration, trophic markers, stable isotopes and molecular genetics, are reviewed and their main advantages and disadvantages for qualitative and quantitative approaches are discussed. The challenges to perform the partitioning of ingestion, digestion and assimilation are discussed together with different approaches to address each of these processes for short- and long-term fingerprinting. Future directions for research on the trophic ecology of benthic marine invertebrates with bi-phasic life cycles are discussed with emphasis on five guidelines that will allow for systematic study and comparative meta-analysis to address important unresolved questions. © 2015 Elsevier Ltd. All rights reserved.
Radhakrishnan, Janani; Subramanian, Anuradha; Sethuraman, Swaminathan
2017-11-01
Articular hyaline cartilage regeneration remains challenging due to its less intrinsic reparability. The study develops injectable biphasic semi-interpenetrating polymer networks (SIPN) hydrogel impregnated with chondroitin sulfate (ChS) nanoparticles for functional cartilage restoration. ChS loaded zein nanoparticles (∼150nm) prepared by polyelectrolyte-protein complexation were interspersed into injectable SIPNs developed by blending alginate with poly(vinyl alcohol) and calcium crosslinking. The hydrogel exhibited interconnected porous microstructure (39.9±5.8μm pore diameter, 57.7±5.9% porosity), 92% swellability and >350Pa elastic modulus. Primary chondrocytes compatibility, chondrocyte-matrix interaction with cell-cell clustering and spheroidal morphology was demonstrated in ChS loaded hydrogel and long-term (42days) proliferation was also determined. Higher fold expression of cartilage-specific genes sox9, aggrecan and collagen-II was observed in ChS loaded hydrogel while exhibiting poor expression of collagen-I. Immunoblotting of aggregan and collagen II demonstrate favorable positive influence of ChS on chondrocytes. Thus, the injectable biphasic SIPNs could be promising composition-mimetic substitute for cartilage restoration at irregular defects. Copyright © 2017 Elsevier Ltd. All rights reserved.
Energy Technology Data Exchange (ETDEWEB)
Estruga, M; Domenech, X; Ayllon, J A [Departament de Quimica, Universitat Autonoma de Barcelona, Campus UAB, E-08193 Bellaterra (Spain); Domingo, C [Institut de Ciencia dels Materials de Barcelona (CSIC), Campus UAB, E-08193 Bellaterra (Spain)], E-mail: joseantonio.ayllon@uab.es, E-mail: mestruga@qf.uab.cat
2009-03-25
Anatase and rutile biphasic nanostructured titania (TiO{sub 2}) has been synthesized via hydrolysis of titanium tetraisopropoxide in an aqueous solution of hydrobromic acid (HBr) and N,N-dimethylformamide (DMF) at 80 deg. C for 16 h. The presence of DMF, which was partially hydrolyzed during the process, determined the formation of a biphasic material. Powder x-ray diffraction showed the presence of both anatase and rutile titania phases in a ratio of approx. 1:1. Transmission electron microscope analysis showed that rutile was present as radial flower-like nanorods, which were surrounded by anatase spherical nanoparticles of 5 nm diameter. Low temperature nitrogen adsorption-desorption analysis showed the characteristic hysteresis loop of a mesoporous material. Specific surface area reached a value of 120 m{sup 2} g{sup -1} and the average pore diameter was 50 A. X-ray photoelectron spectroscopic analysis revealed that interstitial nitrogen was incorporated (0.35 at.%) during the annealing process. According to ultraviolet (UV)-visible diffuse reflectance spectroscope characterization, the N-doping caused a bandgap reduction from 3.0 to 2.9 eV. Photocatalytic activity of the material was tested for the degradation of methylene blue, methyl orange and 4-nitrophenol under near-UV and visible light radiation.
Biphasic 201thallium scintgraphy after dipyridamole in mitral valve diseases
International Nuclear Information System (INIS)
Schmoliner, R.; Dudczak, R.; Kronik, G.; Moesslacher, H.; Kletter, K.; Frischauf, H.
1980-01-01
The results of biphasic 201 thallium scintigraphy after dipyridamole i.v. could neither prove nor exclude the presence of small focal lesions in the myocardium of 17 patients with mitral valve diseases. The frequent finding of a decrease in activity in the anterolateral myocardium is probably due to a relative increase in activity in the region of the inferior wall with superimposed areas of the papillary muscle and right ventricular myocardium. If the right ventricle is visualized in stress- or redistribution images, an increase in mean pulmonary artery pressure can be accepted. According to Cohen's criteria, a grade 2 or 3 virtually proves the existence of pulmonary hypertension, a grade 1 makes this finding rather probable. The possibility of pulmonary hypertension can not be excluded if the right ventricular myocardium is not visualized. (orig.) [de
In efforts to apply a polymer-based aqueous biphasic system (ABS) extraction to the paper pulping process, the study of the distribution of various lignin and cellulosic fractions in ABS and the effects of temperature on system composition and solute partitioning have been inv...
Diagnostic Value of CT Arthrography for Evaluation of Osteochondral Lesions at the Ankle
Directory of Open Access Journals (Sweden)
Jan S. Kirschke
2016-01-01
Full Text Available Background. To retrospectively determine the diagnostic value of computed tomography arthrography (CTA of the ankle in the evaluation of (osteochondral lesions in comparison to conventional magnetic resonance imaging (MRI and intraoperative findings. Methods. A total of N=79 patients had CTAs and MRI of the ankle; in 17/79 cases surgical reports with statements on cartilage integrity were available. Cartilage lesions and bony defects at talus and tibia were scored according to defect depth and size by two radiologists. Statistical analysis included sensitivity analyses and Cohen’s kappa calculations. Results. On CTA, 41/79 and 31/79 patients had full thickness cartilage defects at the talus and at the tibia, respectively. MRI was able to detect 54% of these defects. For the detection of full thickness cartilage lesions, interobserver agreement was substantial (0.72 ± 0.05 for CTA and moderate (0.55 ± 0.07 for MRI. In surgical reports, 88–92% and 46–62% of full thickness defects detected by CTA and MRI were described. CTA findings changed the further clinical management in 15.4% of cases. Conclusions. As compared to conventional MRI, CTA improves detection and visualization of cartilage defects at the ankle and is a relevant tool for treatment decisions in unclear cases.
Why are mini-implants lost: the value of the implantation technique!
Romano, Fabio Lourenço; Consolaro, Alberto
2015-01-01
The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.
Why are mini-implants lost: The value of the implantation technique!
Directory of Open Access Journals (Sweden)
Fabio Lourenço Romano
2015-02-01
Full Text Available The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1 Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2 Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3 Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4 The more precise the lancing procedures, the better the implant placement technique; 5 Self-drilling does not mean higher pressures; 6 Knowing where implant placement should end decreases the risk of complications and mini-implant loss.
Gómez-Barrena, Enrique; Rosset, Philippe; Gebhard, Florian; Hernigou, Philippe; Baldini, Nicola; Rouard, Helène; Sensebé, Luc; Gonzalo-Daganzo, Rosa M; Giordano, Rosaria; Padilla-Eguiluz, Norma; García-Rey, Eduardo; Cordero-Ampuero, José; Rubio-Suárez, Juan Carlos; Stanovici, Julien; Ehrnthaller, Christian; Huber-Lang, Markus; Flouzat-Lachaniette, Charles Henri; Chevallier, Nathalie; Donati, Davide Maria; Ciapetti, Gabriela; Fleury, Sandrine; Fernandez, Manuel-Nicolás; Cabrera, José-Rafael; Avendaño-Solá, Cristina; Montemurro, Tiziana; Panaitescu, Carmen; Veronesi, Elena; Rojewski, Markus Thomas; Lotfi, Ramin; Dominici, Massimo; Schrezenmeier, Hubert; Layrolle, Pierre
2018-03-19
ORTHO-1 is a European, multicentric, first in human clinical trial to prove safety and feasibility after surgical implantation of commercially available biphasic calcium phosphate bioceramic granules associated during surgery with autologous mesenchymal stromal cells expanded from bone marrow (BM-hMSC) under good manufacturing practices, in patients with long bone pseudarthrosis. Twenty-eight patients with femur, tibia or humerus diaphyseal or metaphyso-diaphyseal non-unions were recruited and surgically treated in France, Germany, Italy and Spain with 100 or 200 million BM-hMSC/mL associated with 5-10 cc of bioceramic granules. Patients were followed up during one year. The investigational advanced therapy medicinal product (ATMP) was expanded under the same protocol in all four countries, and approved by each National Competent Authority. With safety as primary end-point, no severe adverse event was reported as related to the BM-hMSC. With feasibility as secondary end-point, the participating production centres manufactured the BM-hMSC as planned. The ATMP combined to the bioceramic was surgically delivered to the non-unions, and 26/28 treated patients were found radiologically healed at one year (3 out of 4 cortices with bone bridging). Safety and feasibility were clinically proven for surgical implantation of expanded autologous BM-hMSC with bioceramic. EU-FP7-HEALTH-2009, REBORNE Project (GA: 241876). Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Biphasic interactions between a cationic dendrimer and actin.
Ruenraroengsak, Pakatip; Florence, Alexander T
2010-12-01
Gene delivery systems face the problem not only of the route toward the cell and tissues in question, but also of the molecularly crowded environment of both the cytoplasm and the nucleus itself. One of the physical barriers in the cytoplasm for diffusing nanoparticles is an actin network. Here, we describe the finding that a self-fluorescent sixth generation cationic dendrimer (6 nm in diameter) interacts reversibly and possibly electrostatically with actin filaments in vitro. Not only does this interaction slow the diffusion of the dendrimer but it also affects actin polymerization in a biphasic manner. At low concentrations the dendrimer behaves like a G-binding actin protein, retarding actin polymerization, whereas at high concentrations the dendrimer acts as a nucleating protein accelerating the polymerization. Thus in vivo the diffusion of a dendrimer carrier such as this has both physical and chemical elements: by decreasing polymerization it might accelerate its own transport, and by enhancing actin polymerization retard it. This finding suggests that such a dendrimer may have a role as an anticancer agent through its inhibitory effect on actin polymerization.
A biphasic model for bleeding in soft tissue
Chang, Yi-Jui; Chong, Kwitae; Eldredge, Jeff D.; Teran, Joseph; Benharash, Peyman; Dutson, Erik
2017-11-01
The modeling of blood passing through soft tissues in the body is important for medical applications. The current study aims to capture the effect of tissue swelling and the transport of blood under bleeding or hemorrhaging conditions. The soft tissue is considered as a non-static poro-hyperelastic material with liquid-filled voids. A biphasic formulation effectively, a generalization of Darcy's law-is utilized, treating the phases as occupying fractions of the same volume. The interaction between phases is captured through a Stokes-like friction force on their relative velocities and a pressure that penalizes deviations from volume fractions summing to unity. The soft tissue is modeled as a hyperelastic material with a typical J-shaped stress-strain curve, while blood is considered as a Newtonian fluid. The method of Smoothed Particle Hydrodynamics is used to discretize the conservation equations based on the ease of treating free surfaces in the liquid. Simulations of swelling under acute hemorrhage and of draining under gravity and compression will be demonstrated. Ongoing progress in modeling of organ tissues under injuries and surgical conditions will be discussed.
Primary prevention of peri-implantitis: Managing peri-implant mucositis
Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; LAMBERT, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni; Schwarz, Frank; Serino, Giovanni
2015-01-01
Abstract AIMS: Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considere...
Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants
Directory of Open Access Journals (Sweden)
Marco Franchi
2004-01-01
Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant
Survival of dental implants placed in sites of previously failed implants.
Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann
2017-11-01
To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sub-meninges implantation reduces immune response to neural implants.
Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L
2013-04-15
Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.
Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection
DEFF Research Database (Denmark)
Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning
2017-01-01
OBJECTIVES: The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. MATERIAL AND METHODS: A MEDLINE (PubMed), Embase and Cochrane library search......-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone...... loss around implants with a scalloped implant-abutment connection. CONCLUSIONS: A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must...
Comparison between FEBio and Abaqus for biphasic contact problems.
Meng, Qingen; Jin, Zhongmin; Fisher, John; Wilcox, Ruth
2013-09-01
Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of this study was to undertake a direct comparison between FEBio and Abaqus for some practical contact problems involving cartilage. Three model types, representing a porous flat-ended indentation test, a spherical-ended indentation test, and a conceptual natural joint contact model, were compared. In addition, a parameter sensitivity study was also performed for the spherical-ended indentation test to investigate the effects of changes in the input material properties on the model outputs, using both FEBio and Abaqus. Excellent agreement was found between FEBio and Abaqus for all of the model types and across the range of material properties that were investigated.
Imaging of common breast implants and implant-related complications: A pictorial essay.
Shah, Amisha T; Jankharia, Bijal B
2016-01-01
The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.
MRI evaluation of a new scaffold-based allogenic chondrocyte implantation for cartilage repair
International Nuclear Information System (INIS)
Dhollander, A.A.M.; Huysse, W.C.J.; Verdonk, P.C.M.; Verstraete, K.L.; Verdonk, R.; Verbruggen, G.; Almqvist, K.F.
2010-01-01
Aim: The present study was designed to evaluate the implantation of alginate beads containing human mature allogenic chondrocytes for the treatment of symptomatic cartilage defects of the knee. MRI was used for the morphological analysis of cartilage repair. The correlation between MRI findings and clinical outcome was also studied. Methods: A biodegradable, alginate-based biocompatible scaffold containing human mature allogenic chondrocytes was used for the treatment of symptomatic chondral and osteochondral lesions in the knee. Twenty-one patients were prospectively evaluated with use of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Visual Analogue Scale (VAS) for pain preoperatively and at 3, 6, 9 and 12 months of follow-up. Of the 21 patients, 12 had consented to follow the postoperative MRI evaluation protocol. MRI data were analyzed based on the original MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) and modified MOCART scoring system. The correlation between the clinical outcome and MRI findings was evaluated. Results: A statistically significant clinical improvement became apparent after 6 months and patients continued to improve during the 12 months of follow-up. One of the two MRI scoring systems that were used, showed a statistically significant deterioration of the repair tissue at 1 year of follow-up. Twelve months after the operation complete filling or hypertrophy was found in 41.6%. Bone-marrow edema and effusion were seen in 41.7% and 25% of the study patients, respectively. We did not find a consistent correlation between the MRI criteria and the clinical results. Discussion: The present study confirmed the primary role of MRI in the evaluation of cartilage repair. Two MOCART-based scoring systems were used in a longitudinal fashion and allowed a practical and morphological evaluation of the repair tissue. However, the correlation between clinical outcome and MRI findings was poor. Further
MRI evaluation of a new scaffold-based allogenic chondrocyte implantation for cartilage repair
Energy Technology Data Exchange (ETDEWEB)
Dhollander, A.A.M., E-mail: Aad.Dhollander@Ugent.b [Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185, 1P5, B9000 Gent (Belgium); Huysse, W.C.J., E-mail: Wouter.Huysse@Ugent.b [Department of Radiology, Ghent University Hospital, De Pintelaan 185, -1K12 IB, B9000 Gent (Belgium); Verdonk, P.C.M., E-mail: pverdonk@yahoo.co [Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185, 1P5, B9000 Gent (Belgium); Verstraete, K.L., E-mail: Koenraad.Verstraete@Ugent.b [Department of Radiology, Ghent University Hospital, De Pintelaan 185, -1K12 IB, B9000 Gent (Belgium); Verdonk, R., E-mail: Rene.Verdonk@Ugent.b [Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185, 1P5, B9000 Gent (Belgium); Verbruggen, G., E-mail: Gust.Verbruggen@Ugent.b [Laboratory of Connective Tissue Biology, Department of Rheumatology, Ghent University Hospital, De Pintelaan 185, Ghent (Belgium); Almqvist, K.F., E-mail: Fredrik.Almqvist@Ugent.b [Department of Orthopaedic Surgery and Traumatology, Ghent University Hospital, De Pintelaan 185, 1P5, B9000 Gent (Belgium)
2010-07-15
Aim: The present study was designed to evaluate the implantation of alginate beads containing human mature allogenic chondrocytes for the treatment of symptomatic cartilage defects of the knee. MRI was used for the morphological analysis of cartilage repair. The correlation between MRI findings and clinical outcome was also studied. Methods: A biodegradable, alginate-based biocompatible scaffold containing human mature allogenic chondrocytes was used for the treatment of symptomatic chondral and osteochondral lesions in the knee. Twenty-one patients were prospectively evaluated with use of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Visual Analogue Scale (VAS) for pain preoperatively and at 3, 6, 9 and 12 months of follow-up. Of the 21 patients, 12 had consented to follow the postoperative MRI evaluation protocol. MRI data were analyzed based on the original MOCART (Magnetic Resonance Observation of Cartilage Repair Tissue) and modified MOCART scoring system. The correlation between the clinical outcome and MRI findings was evaluated. Results: A statistically significant clinical improvement became apparent after 6 months and patients continued to improve during the 12 months of follow-up. One of the two MRI scoring systems that were used, showed a statistically significant deterioration of the repair tissue at 1 year of follow-up. Twelve months after the operation complete filling or hypertrophy was found in 41.6%. Bone-marrow edema and effusion were seen in 41.7% and 25% of the study patients, respectively. We did not find a consistent correlation between the MRI criteria and the clinical results. Discussion: The present study confirmed the primary role of MRI in the evaluation of cartilage repair. Two MOCART-based scoring systems were used in a longitudinal fashion and allowed a practical and morphological evaluation of the repair tissue. However, the correlation between clinical outcome and MRI findings was poor. Further
Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants
Directory of Open Access Journals (Sweden)
Sung-Eun Kim
2014-09-01
Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.
Energy Technology Data Exchange (ETDEWEB)
Kumar, P. Nandha; Mishra, Sandeep K.; Kannan, S., E-mail: para_kanna@yahoo.com
2015-11-15
A series of magnesium doped non-stoichiometric calcium deficient apatites were synthesized through an aqueous precipitation route. The resultant structural changes during heat treatment were investigated by X-ray diffraction, Raman and FT-IR spectroscopy and Rietveld refinement. The results confirmed the formation of biphasic mixtures comprising Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2} and β-Ca{sub 3}(PO{sub 4}){sub 2} after heat treatment at 1000 °C with the preferential occupancy of Mg{sup 2+} at the crystal lattice of β-Ca{sub 3}(PO{sub 4}){sub 2}. The concentration of Mg{sup 2+} uptake in β-Ca{sub 3}(PO{sub 4}){sub 2} is limited till reaching the stoichiometric ratio of (Ca+Mg)/P=1.67 and beyond this stoichiometric value [(Ca+Mg)/P>1.67], Mg{sup 2+} precipitates as Mg(OH){sub 2} and thereafter gets converted to MgO during heat treatment. Any kind of Mg{sup 2+} uptake in the crystal lattice of Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2} is discarded from the investigation. - Highlights: • Aqueous co-precipitation of calcium deficient apatites with excess magnesium (Mg{sup 2+}) additions. • Heat treatments beyond 800 °C results in the formation of biphasic apatite mixtures. • Mg{sup 2+} gets accommodated at the β-Ca{sub 3}(PO{sub 4}){sub 2} lattice of biphasic mixtures. • Mg{sup 2+} additions exceeding stoichiometric value (Ca/P>1.67) results in its formation as MgO. • Mg{sup 2+} occupancy at β-Ca{sub 3}(PO{sub 4}){sub 2} lattice delays its allotropic conversion α-Ca{sub 3}(PO{sub 4}){sub 2} till 1350 °C.
International Nuclear Information System (INIS)
Schieda, Nicola; McInnes, Matthew D.F.; Cao, Lilly
2014-01-01
To use systematic review to evaluate the diagnostic accuracy of segmental enhancement inversion (SEI) at contrast-enhanced biphasic multi-detector computed tomography (MDCT) for the diagnosis of renal oncocytoma. Several electronic databases were searched through October 2013. Two reviewers independently selected studies that met the inclusion criteria and extracted data. Study quality was assessed with the QUADAS-2 tool. The primary 2 x 2 data were investigated with forest plot and ROC plot of sensitivity and specificity. Four studies met the inclusion criteria (307 patients). Considerable heterogeneity between studies precluded meta-analysis. Two studies from the same group of investigators demonstrated reasonable diagnostic accuracy (sensitivity 59-80 % and specificity 87-99 %), while two others did not (sensitivity 0-6 %, specificity 93-100 %). Possible reasons for this include timing of biphasic MDCT and methods of interpretation but not size of lesion. SEI is a specific imaging finding of renal oncocytoma with highly variable sensitivity. This substantial heterogeneity across studies and between institutions suggests that further validation of this imaging finding is necessary prior to application in clinical practice. (orig.)
Energy Technology Data Exchange (ETDEWEB)
Schieda, Nicola; McInnes, Matthew D.F.; Cao, Lilly [Ottawa Hospital Research Institute, Department of Medical Imaging, Ottawa, ON (Canada)
2014-06-15
To use systematic review to evaluate the diagnostic accuracy of segmental enhancement inversion (SEI) at contrast-enhanced biphasic multi-detector computed tomography (MDCT) for the diagnosis of renal oncocytoma. Several electronic databases were searched through October 2013. Two reviewers independently selected studies that met the inclusion criteria and extracted data. Study quality was assessed with the QUADAS-2 tool. The primary 2 x 2 data were investigated with forest plot and ROC plot of sensitivity and specificity. Four studies met the inclusion criteria (307 patients). Considerable heterogeneity between studies precluded meta-analysis. Two studies from the same group of investigators demonstrated reasonable diagnostic accuracy (sensitivity 59-80 % and specificity 87-99 %), while two others did not (sensitivity 0-6 %, specificity 93-100 %). Possible reasons for this include timing of biphasic MDCT and methods of interpretation but not size of lesion. SEI is a specific imaging finding of renal oncocytoma with highly variable sensitivity. This substantial heterogeneity across studies and between institutions suggests that further validation of this imaging finding is necessary prior to application in clinical practice. (orig.)
Kumar, Vinay V; Ebenezer, Supriya; Kämmerer, Peer W; Jacob, P C; Kuriakose, Moni A; Hedne, Naveen; Wagner, Wilfried; Al-Nawas, Bilal
2016-11-01
The objective of this study was to assess the difference in success rates of implants when using two or four implant-supported-overdentures following segmental mandibular reconstruction with fibula free flap. This prospective, parallel designed, randomized clinical study was conducted with 1:1 ratio. At baseline, all participants already had segmental reconstruction of mandible with free fibula flap. The participants were randomized into two groups: Group-I received implant-supported-overdentures on two tissue-level implants and Group-II received implant-supported-overdentures on four tissue-level implants. Success rates of the implants were evaluated at 3 months, 6 months and 12 months following implant loading using marginal bone level changes as well as peri-implant indices (Buser et al., 1990). 52 patients were randomized into two treatment groups (26 each), out of which 18 patients (36 implants) of Group-I and 17 patients (68 implants) of Group-II were evaluated. One implant in Group-I was lost due to infective complications and one patient in the same group had superior barrel necrosis. There was a statistically significant increase at both time points (p = 0.03, p = 0.04 at 6 months, 12 months) in the amount of marginal bone loss in Group-I (0.4 mm, 0.5 mm at 6 months, 12 months) as compared to Group-II (0.1 mm, 0.2 mm at 6 months, 12 months). There were no clinically significant changes peri-implant parameters between both groups. Peri-implant soft tissue hyperplasia was seen in both groups, 32% of implants at 3-months, 26% at 6-months and 3% at 12-months follow-up. The results of this study show that patients with 2-implant-supported-overdentures had higher marginal bone loss as compared to patients with 4-implant-supported-overdentures. There were no clinically significant differences in peri-implant soft tissue factors in patients with 2- or 4-implant-supported-overdentures. Hyperplastic peri-implant tissues are common in the early implant
Imaging of common breast implants and implant-related complications: A pictorial essay
Directory of Open Access Journals (Sweden)
Amisha T Shah
2016-01-01
Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.
Directory of Open Access Journals (Sweden)
Mohamed Jumshad
2010-01-01
Full Text Available Retrograde peri-implantitis constitutes an important cause for implant failure. Retrograde peri-implantitis may sometimes prove difficult to identify and hence institution of early treatment may not be possible. This paper presents a report of four cases of (the implant placed developing to retrograde peri-implantitis. Three of these implants were successfully restored to their fully functional state while one was lost due to extensive damage. The paper highlights the importance of recognizing the etiopathogenic mechanisms, preoperative assessment, and a strong postoperative maintenance protocol to avoid retrograde peri-implant inflammation.
Godazgar, Mahdieh; Zhang, Quan; Chibalina, Margarita V; Rorsman, Patrik
2018-05-01
Na + current inactivation is biphasic in insulin-secreting cells, proceeding with two voltage dependences that are half-maximal at ∼-100 mV and -60 mV. Inactivation of voltage-gated Na + (Na V ) channels occurs at ∼30 mV more negative voltages in insulin-secreting Ins1 and primary β-cells than in HEK, CHO or glucagon-secreting αTC1-6 cells. The difference in inactivation between Ins1 and non-β-cells persists in the inside-out patch configuration, discounting an involvement of a diffusible factor. In Ins1 cells and primary β-cells, but not in HEK cells, inactivation of a single Na V subtype is biphasic and follows two voltage dependences separated by 30-40 mV. We propose that Na V channels adopt different inactivation behaviours depending on the local membrane environment. Pancreatic β-cells are equipped with voltage-gated Na + channels that undergo biphasic voltage-dependent steady-state inactivation. A small Na + current component (10-15%) inactivates over physiological membrane potentials and contributes to action potential firing. However, the major Na + channel component is completely inactivated at -90 to -80 mV and is therefore inactive in the β-cell. It has been proposed that the biphasic inactivation reflects the contribution of different Na V α-subunits. We tested this possibility by expression of TTX-resistant variants of the Na V subunits found in β-cells (Na V 1.3, Na V 1.6 and Na V 1.7) in insulin-secreting Ins1 cells and in non-β-cells (including HEK and CHO cells). We found that all Na V subunits inactivated at 20-30 mV more negative membrane potentials in Ins1 cells than in HEK or CHO cells. The more negative inactivation in Ins1 cells does not involve a diffusible intracellular factor because the difference between Ins1 and CHO persisted after excision of the membrane. Na V 1.7 inactivated at 15--20 mV more negative membrane potentials than Na V 1.3 and Na V 1.6 in Ins1 cells but this small difference is insufficient to solely
Zhu, Shouan; Chen, Pengfei; Wu, Yan; Xiong, Si; Sun, Heng; Xia, Qingqing; Shi, Libing; Liu, Huanhuan; Ouyang, Hong Wei
2014-10-01
Hyaline cartilage differentiation is always the challenge with application of stem cells for joint repair. Transforming growth factors (TGFs) and bone morphogenetic proteins can initiate cartilage differentiation but often lead to hypertrophy and calcification, related to abnormal Rac1 activity. In this study, we developed a strategy of programmed application of TGFβ3 and Rac1 inhibitor NSC23766 to commit the hyaline cartilage differentiation of adipose-derived stem cells (ADSCs) for joint cartilage repair. ADSCs were isolated and cultured in a micromass and pellet culture model to evaluate chondrogenic and hypertrophic differentiation. The function of Rac1 was investigated with constitutively active Rac1 mutant and dominant negative Rac1 mutant. The efficacy of ADSCs with programmed application of TGFβ3 and Rac1 inhibitor for cartilage repair was studied in a rat model of osteochondral defects. The results showed that TGFβ3 promoted ADSCs chondro-lineage differentiation and that NSC23766 prevented ADSC-derived chondrocytes from hypertrophy in vitro. The combination of ADSCs, TGFβ3, and NSC23766 promoted quality osteochondral defect repair in rats with much less chondrocytes hypertrophy and significantly higher International Cartilage Repair Society macroscopic and microscopic scores. The findings have illustrated that programmed application of TGFβ3 and Rac1 inhibitor NSC23766 can commit ADSCs to chondro-lineage differentiation and improve the efficacy of ADSCs for cartilage defect repair. These findings suggest a promising stem cell-based strategy for articular cartilage repair. ©AlphaMed Press.
MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the knee
Energy Technology Data Exchange (ETDEWEB)
Ojala, Risto; Kerimaa, Pekka; Tervonen, Osmo; Blanco-Sequeiros, Roberto [Oulu University Hospital, Department of Radiology, Oulu (Finland); Lakovaara, Martti [Oulu Deaconess Institute, Department of Surgery, Oulu (Finland); Hyvoenen, Pekka; Lehenkari, Petri [Oulu University Hospital, Department of Surgery, Oulu (Finland)
2011-06-15
The purpose of this study was to evaluate the feasibility of a new method for osteochondritis dissecans (OCD) treatment. Ten OCD lesions of the knee unresponsive to conservative management were treated with MRI-guided percutaneous retrograde drilling to reduce symptoms and promote ossification of the lesion. All lesions were located in distal femoral condyles. Only stable OCD lesions were included (preprocedural MRI grade I or II). Five lesions were of juvenile type and five lesions were of adult type OCD. All the patients had severe limitation of activity due to the OCD-related pain. By using a 0.23 T open MRI scanner and spinal anesthesia, percutaneous retrograde drilling of the OCD lesions was performed (3 mm cylindrical drill, one to three channels). Optical tracking and MRI imaging were used to guide instruments during the procedure. Mean postprocedural clinical follow-up time was 3 years. Eight patients had a post-procedural follow-up MRI within 1 year. All the OCD lesions were located and drilled using the 0.23 T open MRI scanner without procedural complications. All the patients had pain relief, mean visual analog score (VAS) declined from 6 to 2. Follow-up MRI showed ossification in all lesions. Eight patients could return to normal physical activity with no or minor effect on function (Hughston score 3-4). Treatment failed in two cases where the continuation of symptoms led to arthroscopy and transchondral fixation. MR-guided retrograde OCD lesion drilling is an accurate, feasible, and effective cartilage-sparing techique in OCD management. (orig.)
Osteochondral fragmentation of the distal aspect of the patella in horses
International Nuclear Information System (INIS)
McIlwraith, C.W.
1990-01-01
A condition characterised by osteochondral fragmentation of the distal aspect of the patella in 15 horses is described. The problem was unilateral in six horses and bilateral in nine. There were eight Quarterhorses, three Thoroughbreds, two American Saddlebreds, one American Paint and one Warmblood-Thoroughbred cross. A previous medial patellar desmotomy had been performed on 12 of the 15 horses. The condition manifested as hindlimb lameness and stiffness ranging from mild to severe. There was fibrous thickening in the stifle area in the 12 cases with a previous medial patellar desmotomy, and synovial effusion in seven of 12 cases. Synovial effusion was present in two of the three cases in which a previous medial patellar desmotomy was not performed. The radiographic changes included bony fragmentation, spurring (with or without an associated subchondral defect), subchondral roughening and subchondral lysis of the distal aspect of the patella. All horses were treated with arthroscopic surgery. The lesions at arthroscopy varied from flaking, fissuring, undermining or fragmentation of the articular cartilage to fragmentation or lysis of the bone at the distal aspect of the patella. The subchondral bone was involved in all cases that had a previous medial patellar desmotomy. Of the 12 horses that had a previous medial patellar desmotomy, eight became sound at their intended use, one was sold in training without problems, one is in early training without problems, one never improved and one is in convalescence. Of the three that did not have a patellar desmotomy, two performed their intended use well but one was unsatisfactory
MRI-guided percutaneous retrograde drilling of osteochondritis dissecans of the knee
International Nuclear Information System (INIS)
Ojala, Risto; Kerimaa, Pekka; Tervonen, Osmo; Blanco-Sequeiros, Roberto; Lakovaara, Martti; Hyvoenen, Pekka; Lehenkari, Petri
2011-01-01
The purpose of this study was to evaluate the feasibility of a new method for osteochondritis dissecans (OCD) treatment. Ten OCD lesions of the knee unresponsive to conservative management were treated with MRI-guided percutaneous retrograde drilling to reduce symptoms and promote ossification of the lesion. All lesions were located in distal femoral condyles. Only stable OCD lesions were included (preprocedural MRI grade I or II). Five lesions were of juvenile type and five lesions were of adult type OCD. All the patients had severe limitation of activity due to the OCD-related pain. By using a 0.23 T open MRI scanner and spinal anesthesia, percutaneous retrograde drilling of the OCD lesions was performed (3 mm cylindrical drill, one to three channels). Optical tracking and MRI imaging were used to guide instruments during the procedure. Mean postprocedural clinical follow-up time was 3 years. Eight patients had a post-procedural follow-up MRI within 1 year. All the OCD lesions were located and drilled using the 0.23 T open MRI scanner without procedural complications. All the patients had pain relief, mean visual analog score (VAS) declined from 6 to 2. Follow-up MRI showed ossification in all lesions. Eight patients could return to normal physical activity with no or minor effect on function (Hughston score 3-4). Treatment failed in two cases where the continuation of symptoms led to arthroscopy and transchondral fixation. MR-guided retrograde OCD lesion drilling is an accurate, feasible, and effective cartilage-sparing techique in OCD management. (orig.)
DEFF Research Database (Denmark)
Niskanen, Leo; Leiter, Lawrence A; Franek, Edward
2012-01-01
Insulin degludec/insulin aspart (IDegAsp) is a soluble co-formulation of insulin degludec (70%) and insulin aspart (IAsp: 30%). Here, we compare the efficacy and safety of IDegAsp, an alternative IDegAsp formulation (AF: containing 45% IAsp), and biphasic IAsp 30 (BIAsp 30)....
Directory of Open Access Journals (Sweden)
Ivan Dotsinsky
2013-04-01
Full Text Available Three waveforms for transthoracic defibrillation are assessed and compared: the Pulsed Biphasic Waveform (PBW, the Rectilinear Biphasic Waveform (RBW, and the "lossless" constant current (LLCC pulses. Two indices are introduced: 1 kf = W/W0 - the ratio between the delivered energy W and the energy W0 of a rectangular pulse with the same duration and electric charge; 2 ηC = W/WC0 - the level of utilizing the initially loaded capacitor energy WC0. The envisioned comparative study shows that ηC index is favorable for both PBW and LLCC, while kf of both RBW and LLCC demonstrates advantage over the PBW in the range of small inter-electrode thoracic impedances below 80 Ω. Some design considerations are also discussed. The attractive LLCC concept needs large and heavy inductive coil to support the constant current amplitude, besides it is capable to induce strong electromagnetic influences due to the complex current control. The RBW technology controls the delivery of current through a series of internal resistors which are, however, a source of high heat losses. The PBW implements controlled duty cycle of high-frequency chopped pulses to adapt the energy delivery in respect of the patient impedance measured at the beginning of the shock. PBW technology makes use of small capacitors which allows the construction of light weight and small-size portable devices for transthoracic defibrillation.
Directory of Open Access Journals (Sweden)
Citro Gennaro
2008-11-01
Full Text Available Abstract Sticker's sarcoma (also known as transmissible venereal tumor is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT, treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy. Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 μs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations.
Biphasic effect of citral, a flavoring and scenting agent, on spatial learning and memory in rats.
Yang, Zheqiong; Xi, Jinlei; Li, Jihong; Qu, Wen
2009-10-01
Although some central effects of citral have been reported, cognitive effects on spatial memory have not been investigated. The evidence showed that citral can regulate the synthesis of retinoic acid (RA), which exerts a vital function in the development and maintenance of spatial memory. In this study, we applied Morris water maze to test the effect of citral on animals' spatial learning and memory. To elucidate the mechanism of this effect, we also measured the retinoic acid concentration in rats' hippocampus by high performance liquid chromatography (HPLC). Our data implied biphasic effects of citral. The low dose (0.1 mg/kg) of citral improved the spatial learning capability, and enhanced the spatial reference memory of rats, whereas the high dose (1.0 mg/kg) was like to produce the opposite effects. Meanwhile, the low dose of citral increased the hippocampal retinoic acid concentration, while the high dose decreased it. Due to the quick elimination and non-bioaccumulation in the body, effects of citral on spatial memory in this study seemed to be indirect actions. The change in hippocampal retinoic acid concentration induced by different doses of citral might be responsible for the biphasic effect of citral on spatial learning and memory.
Bai, Qiufang; Song, Dan; Gu, Li; Verkhratsky, Alexei; Peng, Liang
2017-04-01
Here, we present the data indicating that chronic treatment with fluoxetine regulates Cav-1/PTEN/PI3K/AKT/GSK-3β signalling pathway and glycogen content in primary cultures of astrocytes with bi-phasic concentration dependence. At lower concentrations, fluoxetine downregulates gene expression of Cav-1, decreases membrane content of PTEN, increases activity of PI3K/AKT, and elevates GSK-3β phosphorylation thus suppressing its activity. At higher concentrations, fluoxetine acts in an inverse fashion. As expected, fluoxetine at lower concentrations increased while at higher concentrations decreased glycogen content in astrocytes. Our findings indicate that bi-phasic regulation of glycogen content via Cav-1/PTEN/PI3K/AKT/GSK-3β pathway by fluoxetine may be responsible for both therapeutic and side effects of the drug.
Schwarz, Frank; Mihatovic, Ilja; Golubovic, Vladimir; Hegewald, Andrea; Becker, Jürgen
2012-01-01
To assess the influence of two barrier membranes and two bone graft substitutes mixed with autogenous bone (AB) on staged guided bone regeneration and osseointegration of titanium implants in dogs. Four saddle-type defects each were prepared in the upper jaw of six fox hounds and randomly filled with a natural bone mineral (NBM)+AB and a biphasic calcium phosphate (SBC)+AB and allocated to either an in situ gelling polyethylene glycol (PEG) or a collagen membrane (CM). At 8 weeks, modSLA titanium implants were inserted and left to heal in a submerged position. At 8+2 weeks, dissected blocks were processed for histomorphometrical analysis (e.g., treated area [TA], bone-to-implant contact [BIC]). The mean TA values (mm(2) ) and BIC values (%) tended to be higher in the PEG groups(TA: NBM+AB [10.4 ± 2.5]; SBC+AB [10.4 ± 5.8]/BIC: NBM+AB [86.4 ± 20.1]; SBC+AB [80.1 ± 21.5]) when compared with the corresponding CM groups (TA: NBM+AB [9.7 ± 4.8]; SBC+AB [7.8 ± 4.3]/BIC: NBM+AB [71.3 ± 20.8]; SBC+AB [72.4 ± 20.3]). A significant difference was observed for the mean TA values in the SBC+AB groups. It was concluded that all augmentation procedures investigated supported bone regeneration and staged osseointegration of modSLA titanium implants. However, the application of PEG may be associated with increased TA values. © 2011 John Wiley & Sons A/S.
Cochlear implants in children implanted in Jordan: A parental overview.
Alkhamra, Rana A
2015-07-01
Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.
Long time follow up of implant therapy and treatment of peri-implantitis.
Roos-Jansåker, Ann-Marie
2007-01-01
Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on
... Implants and Prosthetics Metal-on-Metal Hip Implants Hip Implants Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Hip implants are medical devices intended to restore mobility ...
Age at implantation and auditory memory in cochlear implanted children.
Mikic, B; Miric, D; Nikolic-Mikic, M; Ostojic, S; Asanovic, M
2014-05-01
Early cochlear implantation, before the age of 3 years, provides the best outcome regarding listening, speech, cognition an memory due to maximal central nervous system plasticity. Intensive postoperative training improves not only auditory performance and language, but affects auditory memory as well. The aim of this study was to discover if the age at implantation affects auditory memory function in cochlear implanted children. A total of 50 cochlear implanted children aged 4 to 8 years were enrolled in this study: early implanted (1-3y) n = 27 and late implanted (4-6y) n = 23. Two types of memory tests were used: Immediate Verbal Memory Test and Forward and Backward Digit Span Test. Early implanted children performed better on both verbal and numeric tasks of auditory memory. The difference was statistically significant, especially on the complex tasks. Early cochlear implantation, before the age of 3 years, significantly improve auditory memory and contribute to better cognitive and education outcomes.
Breast reconstruction - implants
Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...
Nicoll, Roxanna J; Sun, Albert; Haney, Stephan; Turkyilmaz, Ilser
2013-01-01
The fabrication of an accurately fitting implant-supported fixed prosthesis requires multiple steps, the first of which is assembling the impression coping on the implant. An imprecise fit of the impression coping on the implant will cause errors that will be magnified in subsequent steps of prosthesis fabrication. The purpose of this study was to characterize the 3-dimensional (3D) precision of fit between impression coping and implant replica pairs for 3 implant systems. The selected implant systems represent the 3 main joint types used in implant dentistry: external hexagonal, internal trilobe, and internal conical. Ten impression copings and 10 implant replicas from each of the 3 systems, B (Brånemark System), R (NobelReplace Select), and A (NobelActive) were paired. A standardized aluminum test body was luted to each impression coping, and the corresponding implant replica was embedded in a stone base. A coordinate measuring machine was used to quantify the maximum range of displacement in a vertical direction as a function of the tightening force applied to the guide pin. Maximum angular displacement in a horizontal plane was measured as a function of manual clockwise or counterclockwise rotation. Vertical and rotational positioning was analyzed by using 1-way analysis of variance (ANOVA). The Fisher protected least significant difference (PLSD) multiple comparisons test of the means was applied when the F-test in the ANOVA was significant (α=.05). The mean and standard deviation for change in the vertical positioning of impression copings was 4.3 ±2.1 μm for implant system B, 2.8 ±4.2 μm for implant system R, and 20.6 ±8.8 μm for implant system A. The mean and standard deviation for rotational positioning was 3.21 ±0.98 degrees for system B, 2.58 ±1.03 degrees for system R, and 5.30 ±0.79 degrees for system A. The P-value for vertical positioning between groups A and B and between groups A and R was <.001. No significant differences were found for
Directory of Open Access Journals (Sweden)
Byung-Chul Jeong
2015-01-01
Full Text Available Recently a submicron particle of biphasic calcium phosphate ceramic (BCP with through-hole (donut-shaped BCP (d-BCP was developed for improving the osteoconductivity. This study was performed to examine the usefulness of d-BCP for the delivery of osteoinductive rhBMP2 and the effectiveness on cranial bone regeneration. The d-BCP was soaked in rhBMP2 solution and then freeze-dried. Scanning electron microscope (SEM, energy dispersive spectroscopy (EDS, and Raman spectroscopy analyses confirmed that rhBMP2 was well delivered onto the d-BCP surface and the through-hole. The bioactivity of the rhBMP2/d-BCP composite was validated in MC3T3-E1 cells as an in vitro model and in critical-sized cranial defects in C57BL/6 mice. When freeze-dried d-BCPs with rhBMP2 were placed in transwell inserts and suspended above MC3T3-E1, alkaline phosphatase activity and osteoblast-specific gene expression were increased compared to non-rhBMP2-containing d-BCPs. For evaluating in vivo effectiveness, freeze-dried d-BCPs with or without rhBMP2 were implanted into critical-sized cranial defects. Microcomputed tomography and histologic analysis showed that rhBMP2-containing d-BCPs significantly enhanced cranial bone regeneration compared to non-rhBMP2-containing control. These results suggest that a combination of d-BCP and rhBMP2 can accelerate bone regeneration, and this could be used to develop therapeutic strategies in hard tissue healing.
Jeong, Byung-Chul; Choi, Hyuck; Hur, Sung-Woong; Kim, Jung-Woo; Oh, Sin-Hye; Kim, Hyun-Seung; Song, Soo-Chang; Lee, Keun-Bae; Park, Kwang-Bum; Koh, Jeong-Tae
2015-01-01
Recently a submicron particle of biphasic calcium phosphate ceramic (BCP) with through-hole (donut-shaped BCP (d-BCP)) was developed for improving the osteoconductivity. This study was performed to examine the usefulness of d-BCP for the delivery of osteoinductive rhBMP2 and the effectiveness on cranial bone regeneration. The d-BCP was soaked in rhBMP2 solution and then freeze-dried. Scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), and Raman spectroscopy analyses confirmed that rhBMP2 was well delivered onto the d-BCP surface and the through-hole. The bioactivity of the rhBMP2/d-BCP composite was validated in MC3T3-E1 cells as an in vitro model and in critical-sized cranial defects in C57BL/6 mice. When freeze-dried d-BCPs with rhBMP2 were placed in transwell inserts and suspended above MC3T3-E1, alkaline phosphatase activity and osteoblast-specific gene expression were increased compared to non-rhBMP2-containing d-BCPs. For evaluating in vivo effectiveness, freeze-dried d-BCPs with or without rhBMP2 were implanted into critical-sized cranial defects. Microcomputed tomography and histologic analysis showed that rhBMP2-containing d-BCPs significantly enhanced cranial bone regeneration compared to non-rhBMP2-containing control. These results suggest that a combination of d-BCP and rhBMP2 can accelerate bone regeneration, and this could be used to develop therapeutic strategies in hard tissue healing.
Gracitelli, Guilherme C; Meric, Gokhan; Briggs, Dustin T; Pulido, Pamela A; McCauley, Julie C; Belloti, João Carlos; Bugbee, William D
2015-04-01
In most treatment algorithms, osteochondral allograft (OCA) transplantation is regarded as an alternative salvage procedure when other, previous reparative treatments have failed. To compare the outcomes of a retrospective matched-pair cohort of (1) primary OCA transplantation and (2) OCA transplantation after failure of previous subchondral marrow stimulation. Cohort study; Level of evidence, 3. An OCA database was used to identify 46 knees that had OCA transplantation performed as a primary treatment (group 1) and 46 knees that underwent OCA transplantation after failure of previous subchondral marrow stimulation (group 2). All patients had a minimum of 2 years' follow-up. Patients in each group were matched for age (±5 years), diagnosis (osteochondral lesion, degenerative chondral lesion, traumatic chondral injury), and graft size (small, 10 cm2). The groups had similar body mass indexes, sex distributions, and graft locations (femoral condyle, patella, and trochlea. The number and type of further surgeries after the OCA transplantation were assessed; failure was defined as any reoperation resulting in removal of the graft. Functional outcomes were evaluated by use of the modified Merle d'Aubigné-Postel (18-point) scale, International Knee Documentation Committee (IKDC) subjective knee evaluation form, Knee injury and Osteoarthritis Outcomes Score (KOOS), and the Knee Society function (KS-F) scale. Patient satisfaction, according to a 5-point scale from "extremely satisfied" to "dissatisfied," was recorded at the latest follow-up. Eleven of 46 knees (24%) in group 1 had reoperations, compared with 20 of 46 knees (44%) in group 2 (P = .04). The OCA was classified as a failure in 5 knees (11%) in group 1 and 7 knees (15%) in group 2 (P = .53). At 10 years of follow-up, survivorship of the graft was 87.4% and 86% in groups 1 and 2, respectively. Both groups showed improvement in pain and function on all subjective scores from preoperatively to the latest follow
International Nuclear Information System (INIS)
Johnson, E.
1986-01-01
It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)
Stem cell- and growth factor-based regenerative therapies for avascular necrosis of the femoral head
2012-01-01
Avascular necrosis (AVN) of the femoral head is a debilitating disease of multifactorial genesis, predominately affects young patients, and often leads to the development of secondary osteoarthritis. The evolving field of regenerative medicine offers promising treatment strategies using cells, biomaterial scaffolds, and bioactive factors, which might improve clinical outcome. Early stages of AVN with preserved structural integrity of the subchondral plate are accessible to retrograde surgical procedures, such as core decompression to reduce the intraosseous pressure and to induce bone remodeling. The additive application of concentrated bone marrow aspirates, ex vivo expanded mesenchymal stem cells, and osteogenic or angiogenic growth factors (or both) holds great potential to improve bone regeneration. In contrast, advanced stages of AVN with collapsed subchondral bone require an osteochondral reconstruction to preserve the physiological joint function. Analogously to strategies for osteochondral reconstruction in the knee, anterograde surgical techniques, such as osteochondral transplantation (mosaicplasty), matrix-based autologous chondrocyte implantation, or the use of acellular scaffolds alone, might preserve joint function and reduce the need for hip replacement. This review summarizes recent experimental accomplishments and initial clinical findings in the field of regenerative medicine which apply cells, growth factors, and matrices to address the clinical problem of AVN. PMID:22356811
International Nuclear Information System (INIS)
Rosa, Joyce Rover; Silva, Ingrid S.V. da; Pasquini, Daniel; Santos, Daniele B. dos; Barud, Hernane S.; Ribeiro, Sidney J.L.
2011-01-01
This study aimed to partial oxypropylation of bacterial cellulose (CB), as well as the characterization of pure CB, oxypropylated CB (CBO) and oxypropylated CB after Soxhlet extraction with hexane (CBOE). The oxypropylation reaction was carried out by propylene oxide polymerization, catalyzed by KOH, in the presence of CB The CB samples, before and after modification, were subjected to analysis of scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction, differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). It was possible verify that the partial transformation of bacterial cellulose by inserting a layer of thermoplastic polymer on its surface occurred efficiently, obtaining a biphasic monocomponent composite material. (author)
Energy Technology Data Exchange (ETDEWEB)
Radwan, M.M., E-mail: mmahmoudradwan@yahoo.com [Ceramics Dept, National Research Centre, Cairo (Egypt); Abd El-Hamid, H.K. [Ceramics Dept, National Research Centre, Cairo (Egypt); Mohamed, A.F. [The Holding Company for Production of Vaccines, Sera and Drugs (EGYVAC) (Egypt)
2015-12-01
The influence of using saline solution as mixing and curing liquid on some characteristics of β-dicalcium silicate (β-C{sub 2}S) and biphasic compound tri-calcium phosphate/hydroxyapatite (TCP/HAp) bio-ceramics was investigated. β-C{sub 2}S (27–30 nm) was prepared by solid state reaction at 1450 °C, while biphasic compound TCP/HAp (7–15 nm) was synthesized from an aqueous solution of Ca(NO{sub 3}){sub 2}·4H{sub 2}O and (NH{sub 4}){sub 2}HPO{sub 4}·12H{sub 2}O by chemical precipitation method. Setting times, compressive strength, pH values, X-ray diffraction analysis, infrared spectroscopy, scanning electron microscopy (SEM) were investigated. The evaluation of cytotoxicity of both calcium silicate and biphasic compounds to human gingival fibroblasts was carried out. The use of saline solution as mixing and immersing liquid shortened the setting time for the two bio-cements. TCP/HAp did not show any mechanical strength but β-C{sub 2}S showed good strength values. Both synthesized compounds showed a moderate cytotoxicity and both materials were effective in a no significant way. - Highlights: • The dissolution and hydration of β-C{sub 2}S and TCP/HAp in distilled water and saline solution were studied. • TCP/HAp did not show mechanical strength, while β-C{sub 2}S showed good mechanical strength. • The use of saline solution did enhances the dissolution & hydration rate. • An increase in pH values was detected when using saline solution. • Both materials showed a moderate cytotoxicity in no significant way.
Biphasic whole-cell synthesis of R-2-octanol with recycling of the ionic liquid
Dennewald, Danielle
2011-01-01
Whole-cell biocatalysis in biphasic systems permits the synthesis of inhibiting chiral alcohols if appropriate non-water miscible ionic liquids are used. Taking the asymmetric reduction of 2-octanone to R-2-octanol by a recombinant Escherichia coli as a model reaction, a detailed characterisation of the biocatalytic reaction was performed with [HMPL][NTF] as ionic liquid. This made the asymmetric synthesis of R-2-octanol in a simple batch at a conversion > 99 % and at an enantiomeric excess >...
International Nuclear Information System (INIS)
Hong, H.S.; Byun, J.H.; Won, H.J.; Kim, K.W.; Lee, S.S.; Lee, M.G.; Yun, S.C.
2010-01-01
Aim: To retrospectively evaluate the efficacy of biphasic magnetic resonance imaging (MRI) of the liver with ferucarbotran-enhancement for the characterization of hepatic metastases. Materials and methods: Thirty-six patients underwent MRI of the liver with separate acquisition of double-contrast enhancement consisting of gadolinium and ferucarbotran. A total of 106 focal hepatic lesions (51 metastases, 31 cysts, 23 haemangiomas, and one eosinophilic abscess) were included. Two sets of MRI were analysed: (1) ferucarbotran set: ferucarbotran-enhanced T1-weighted (T1W) dynamic imaging combined with ferucarbotran-enhanced T2*-weighted (T2*W) delayed imaging and (2) double set: gadolinium-enhanced T1W dynamic imaging combined with ferucarbotran-enhanced T2*W delayed imaging. The diagnostic accuracy of the two sets was evaluated using alternative free-response receiver operating characteristic curve analysis. Sensitivity and specificity were compared using the McNemar test. The enhancement pattern of focal hepatic lesions was analysed on gadolinium and ferucarbotran-enhanced T1W dynamic imaging. Results: There was no significant difference in the accuracy of characterizing hepatic metastases between the two sets. Sensitivity and specificity were not significantly different between the sets (p > 0.05). Peripheral rim enhancement was exhibited in 57% of metastatic lesions on ferucarbotran-enhanced T1W dynamic imaging. The majority (96%) of hepatic haemangiomas demonstrated typical peripheral nodular enhancement with progression on ferucarbotran-enhanced T1W dynamic imaging and were easily differentiated from metastases. Conclusion: Biphasic MRI of the liver with ferucarbotran-enhancement alone provided comparable diagnostic efficacy to double-contrast MRI for the characterization of hepatic metastases.
Does the number of implants have any relation with peri-implant disease?
Directory of Open Access Journals (Sweden)
Bernardo Born PASSONI
2014-10-01
Full Text Available Objective: The aim of this study was to evaluate the relationship between the number of pillar implants of implant-supported fixed prostheses and the prevalence of periimplant disease. Material and Methods: Clinical and radiographic data were obtained for the evaluation. The sample consisted of 32 patients with implant-supported fixed prostheses in function for at least one year. A total of 161 implants were evaluated. Two groups were formed according to the number of implants: G1 ≤5 implants and G2 >5 implants. Data collection included modified plaque index (MPi, bleeding on probing (BOP, probing depth (PD, width of keratinized mucosa (KM and radiographic bone loss (BL. Clinical and radiographic data were grouped for each implant in order to conduct the diagnosis of mucositis or peri-implantitis. Results: Clinical parameters were compared between groups using Student’s t test for numeric variables (KM, PD and BL and Mann-Whitney test for categorical variables (MPi and BOP. KM and BL showed statistically significant differences between both groups (p<0.001. Implants from G1 – 19 (20.43% – compared with G2 – 26 (38.24% – showed statistically significant differences regarding the prevalence of peri-implantitis (p=0.0210. Conclusion: It seems that more than 5 implants in total fixed rehabilitations increase bone loss and consequently the prevalence of implants with periimplantitis. Notwithstanding, the number of implants does not have any influence on the prevalence of mucositis.
Tribological properties of nitrogen implanted and boron implanted steels
International Nuclear Information System (INIS)
Kern, K.T.
1996-01-01
Samples of a steel with high chrome content was implanted separately with 75 keV nitrogen ions and with 75 keV boron ions. Implanted doses of each ion species were 2-, 4-, and 8 x 10 17 /cm 2 . Retained doses were measured using resonant non-Rutherford Backscattering Spectrometry. Tribological properties were determined using a pin-on-disk test with a 6-mm diameter ruby pin with a velocity of 0.94 m/min. Testing was done at 10% humidity with a load of 377 g. Wear rate and coefficient of friction were determined from these tests. While reduction in the wear rate for nitrogen implanted materials was observed, greater reduction (more than an order of magnitude) was observed for boron implanted materials. In addition, reduction in the coefficient of friction for high-dose boron implanted materials was observed. Nano-indentation revealed a hardened layer near the surface of the material. Results from grazing incidence x-ray diffraction suggest the formation of Fe 2 N and Fe 3 N in the nitrogen implanted materials and Fe 3 B in the boron implanted materials. Results from transmission electron microscopy will be presented
Cochlear implantation in late-implanted adults with prelingual deafness.
Most, Tova; Shrem, Hadas; Duvdevani, Ilana
2010-01-01
The purpose of this study was to examine the effect of cochlear implantation (CI) on prelingually deafened participants who were implanted as adults. The effect of the CI was examined with regard to the following variables: communication, family, social skills, education, and work satisfaction with one's life, loneliness, and self-esteem. Thirty-eight adults participated. Four self-report questionnaires were used at 2 points in time: before and after CI. The research findings show significant differences in the reports of most variables before and after implantation. The participants felt better with regard to communication, social skills, education, and work and satisfaction with one's life after implantation in comparison to their feelings before implantation. Furthermore, they felt less lonely after implantation. However, there were no significant differences before and after implantation regarding their feelings within the family and regarding their self-esteem. The results demonstrated the need to evaluate the benefits resulting from the CI not only with traditional clinical measures but with additional measures as well. Furthermore, they demonstrated the benefit of the CI on the positive psychosociological implications of prelingually deafened adults. Copyright © 2010 Elsevier Inc. All rights reserved.
Histology of a dental implant with a platform switched implant-abutment connection
Directory of Open Access Journals (Sweden)
Vittoria Perrotti
2011-10-01
Full Text Available Background: Peri-implant crestal bone must be stable for aesthetic reasons. Aim of this study was a histologic analysis of an implant with a platform switched implant-abutment connection. Materials and methods: A 32-year-old male patient participated in this study. The patient needed a bilateral mandibular restoration. Four implants were used, and were immediately restored and loaded the same day of insertion. After a 6 weeks healing period, one implant with platform-switched abutment was retrieved with trephine. Before retrieval the implant was osseointegrated and not mobile. On one side of the implant, a 1 mm resorption of the crestal bone was present. On the contrary, on the other side no bone resorption had occurred and about 1 mm of bone was present over the implant shoulder. Results: The bone-implant contact percentage was 65.1 ± 6.3 %. Platform- switching could help in maintaining the height of the peri-implant crestal bone.
Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-implantitis.
Derks, J; Schaller, D; Håkansson, J; Wennström, J L; Tomasi, C; Berglundh, T
2016-01-01
Peri-implantitis is an inflammatory disease affecting soft and hard tissues surrounding dental implants. As the global number of individuals that undergo restorative therapy through dental implants increases, peri-implantitis is considered as a major and growing problem in dentistry. A randomly selected sample of 588 patients who all had received implant-supported therapy 9 y earlier was clinically and radiographically examined. Prevalence of peri-implantitis was assessed and risk indicators were identified by multilevel regression analysis. Forty-five percent of all patients presented with peri-implantitis (bleeding on probing/suppuration and bone loss >0.5 mm). Moderate/severe peri-implantitis (bleeding on probing/suppuration and bone loss >2 mm) was diagnosed in 14.5%. Patients with periodontitis and with ≥4 implants, as well as implants of certain brands and prosthetic therapy delivered by general practitioners, exhibited higher odds ratios for moderate/severe peri-implantitis. Similarly, higher odds ratios were identified for implants installed in the mandible and with crown restoration margins positioned ≤1.5 mm from the crestal bone at baseline. It is suggested that peri-implantitis is a common condition and that several patient- and implant-related factors influence the risk for moderate/severe peri-implantitis (ClinicalTrials.gov NCT01825772). © International & American Associations for Dental Research 2015.
Bilateral Poly Implant Prothèse Implant Rupture: An Uncommon Presentation
Directory of Open Access Journals (Sweden)
Peter Mallon
2013-07-01
Full Text Available Summary: A woman in her 50s underwent delayed bilateral Poly Implant Prothèse implant reconstruction following mastectomy for breast cancer. Symptoms of implant rupture developed 43 months after surgery with an erythematous rash on her trunk. The rash then spread to her reconstructed breast mounds. Initial ultrasound scan and magnetic resonance imaging were normal; however, subsequent magnetic resonance imaging demonstrated left implant rupture only. In theater, following removal of both implants, both were found to be ruptured. The rash on her trunk resolved within 3 weeks in the postoperative period. Chemical analyses of silicone in both implants confirmed a nonauthorized silicone source; in addition, the chemical structure was significantly different between the left and right implant, perhaps explaining the variation in presentation.
Complications after cardiac implantable electronic device implantations
DEFF Research Database (Denmark)
Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard
2013-01-01
Complications after cardiac implantable electronic device (CIED) treatment, including permanent pacemakers (PMs), cardiac resynchronization therapy devices with defibrillators (CRT-Ds) or without (CRT-Ps), and implantable cardioverter defibrillators (ICDs), are associated with increased patient...
Management of peri-implantitis
Directory of Open Access Journals (Sweden)
Jayachandran Prathapachandran
2012-01-01
Full Text Available Peri-implantitis is a site-specific infectious disease that causes an inflammatory process in soft tissues, and bone loss around an osseointegrated implant in function. The etiology of the implant infection is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, external morphology, and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of color in the gingiva, bleeding and probing depth of peri-implant pockets, suppuration, X-ray, and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of peri-implant mucositis or peri-implantitis. The management of implant infection should be focused on the control of infection, the detoxification of the implant surface, and regeneration of the alveolar bone. This review article deals with the various treatment options in the management of peri-implantitis. The article also gives a brief description of the etiopathogenesis, clinical features, and diagnosis of peri-implantitis.
Pickering interfacial catalysis for biphasic systems: from emulsion design to green reactions.
Pera-Titus, Marc; Leclercq, Loïc; Clacens, Jean-Marc; De Campo, Floryan; Nardello-Rataj, Véronique
2015-02-09
Pickering emulsions are surfactant-free dispersions of two immiscible fluids that are kinetically stabilized by colloidal particles. For ecological reasons, these systems have undergone a resurgence of interest to mitigate the use of synthetic surfactants and solvents. Moreover, the use of colloidal particles as stabilizers provides emulsions with original properties compared to surfactant-stabilized emulsions, microemulsions, and micellar systems. Despite these specific advantages, the application of Pickering emulsions to catalysis has been rarely explored. This Minireview describes very recent examples of hybrid and composite amphiphilic materials for the design of interfacial catalysts in Pickering emulsions with special emphasis on their assets and challenges for industrially relevant biphasic reactions in fine chemistry, biofuel upgrading, and depollution. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Experimental study on bone tissue reaction around HA implants radiated after implantation
International Nuclear Information System (INIS)
Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi
1998-01-01
This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)
One-stage explant-implant procedure of exposed porous orbital implants
DEFF Research Database (Denmark)
Toft, Peter B; Rasmussen, Marie L Roed; Prause, Jan Ulrik
2011-01-01
Purpose: To investigate the risks of implant exposure after a combined explant-implant procedure in patients with an exposed porous orbital implant. Methods: Twenty-four consecutive patients who had a combined explant-implant procedure of an exposed hydroxyapatite (21) or porous polyethylene (3...... at the same procedure in sockets without profound signs of infection. The procedure carries a possible risk of poor motility....
Fritz, M E
1999-06-01
Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of
Deng, Aojie; Lin, Qixuan; Yan, Yuhuan; Li, Huiling; Ren, Junli; Liu, Chuanfu; Sun, Runcang
2016-09-01
A feasible approach was developed to produce furfural from the pre-hydrolysis liquor of corncob via biochar catalysts as the solid acid catalyst in a new biphasic system with dichloromethane (DCM) as the organic phase and the concentrated pre-hydrolysis liquor (CPHL) containing NaCl as the aqueous phase. The biochar catalyst possessing many acidity groups (SO3H, COOH and phenolic OH groups) was prepared by the carbonization and sulfonation process of the corncob hydrolyzed residue. The influence of the catalytic condition on furfural yield and selectivity was comparatively studied. It was found that 81.14% furfural yield and 83.0% furfural selectivity were obtained from CPHL containing 5wt% xylose using this biochar catalyst in the CPHL-NaCl/DCM biphasic system at 170°C for 60min. In addition, with the regeneration process, this catalyst displayed the high performance and excellent recyclability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Alendronate-Eluting Biphasic Calcium Phosphate (BCP Scaffolds Stimulate Osteogenic Differentiation
Directory of Open Access Journals (Sweden)
Sung Eun Kim
2015-01-01
Full Text Available Biphasic calcium phosphate (BCP scaffolds have been widely used in orthopedic and dental fields as osteoconductive bone substitutes. However, BCP scaffolds are not satisfactory for the stimulation of osteogenic differentiation and maturation. To enhance osteogenic differentiation, we prepared alendronate- (ALN- eluting BCP scaffolds. The coating of ALN on BCP scaffolds was confirmed by scanning electron microscopy (FE-SEM, energy-dispersive X-ray spectroscopy (EDS, and attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR. An in vitro release study showed that release of ALN from ALN-eluting BCP scaffolds was sustained for up to 28 days. In vitro results revealed that MG-63 cells grown on ALN-eluting BCP scaffolds exhibited increased ALP activity and calcium deposition and upregulated gene expression of Runx2, ALP, OCN, and OPN compared with the BCP scaffold alone. Therefore, this study suggests that ALN-eluting BCP scaffolds have the potential to effectively stimulate osteogenic differentiation.
Impact of implant design on primary stability of orthodontic mini-implants.
Wilmes, Benedict; Ottenstreuer, Stephanie; Su, Yu-Yu; Drescher, Dieter
2008-01-01
Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability. Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens. We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs. The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.
Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock
2012-01-01
The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.
Ilmi, Miftahul; Hommes, Arne; Winkelman, Jozef; Hidayat, C.; Heeres, Hero
2016-01-01
The kinetics of sunflower oil transesterification with 1-butanol using a homogeneous lipase (Rhizomucor miehei) in an aqueous-organic biphasic system were studied in a stirred batch reactor set-up. An initial screening study was performed to optimize relevant process conditions (enzyme
Santo, Vítor E.; Mano, João F.; Reis, Rui L.
2013-01-01
The potential of growth factors to stimulate tissue healing through the enhancement of cell proliferation, migration, and differentiation is undeniable. However, critical parameters on the design of adequate carriers, such as uncontrolled spatiotemporal presence of bioactive factors, inadequate release profiles, and supraphysiological dosages of growth factors, have impaired the translation of these systems onto clinical practice. This review describes the healing cascades for bone, cartilage, and osteochondral interface, highlighting the role of specific growth factors for triggering the reactions leading to tissue regeneration. Critical criteria on the design of carriers for controlled release of bioactive factors are also reported, focusing on the need to provide a spatiotemporal control over the delivery and presentation of these molecules. PMID:23268651
Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn
Directory of Open Access Journals (Sweden)
S. N. Koval
2006-01-01
Full Text Available Biphasic positive airway pressure (BIPAP (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency is calculated as the ratio between the durations of the two pressure phases, a PTR greater than 1:1 is called APRV (airway pressure release ventilation. In patients with ARDS maintained spontaneous breathing with BIPAP resulted in lower venous admixture and better arterial blood oxygenation as compared with A/C. Only a few studies with BIPAP have been performed in newborn and infants until now. We studied the use of BIPAP in newborn (body mass > 3kg and randomised 40 patients with respiratory failure for ventilation with BIPAP (n=20 or conventional mechanical ventilatory support (assist-control A/C — synchronised intermittent mandatory ventilation (SIMV (n=20. The Pediatric Risk of Mortality score (PRISM were collected for each patient. Fentanyl, diazepam, GABA were used as sedatives and adjusted in accordance with the Cook scale. We compared ventilatory parameters, information pertaining to pulmonary function and oxygen delivery, cardiac output, additional descriptors of organ system functions, duration and complications of ventilation and number and dosages of sedatives administered. All the patients that we intended to ventilate with BIPAP were successfully ventilated, we can conclude that biphasic ventilatory support suitable mode of ventilation for newborn with a decreased need of analgetics and sedatives than A/C. Finally, BIPAP is an a effective safe, and easy to use for personal mode of mechanical ventilatory support in newborn.
Energy Technology Data Exchange (ETDEWEB)
Rogers, R.D.; Bond, A.H.; Zhang, Jianhua [Northern Illinois Univ., De Kalb, IL (United States). Dept. of Chemistry; Horwitz, P. [Argonne National Lab., IL (United States)
1995-12-31
Two new schemes for TcO{sub 4}{sup {minus}}/MoO{sub 4}{sup 2{minus}} separations from OH{sup {minus}} and MoO{sub 4}{sup 2{minus}} media using polyethylene glycol (PEG)-based aqueous biphasic systems (ABS) have been developed. The two most important salt solutions in current {sup 99m}Tc-generator technologies, OH{sup {minus}} and MoO{sub 4}{sup 2{minus}}, also salt out PEG to form ABS. In liquid/liquid PEG- ABS, pertechnetate can be separated from molybdate with separation factors as high as 10,000. Stripping is accomplished by reduction of the TcO{sub 4}{sup {minus}} and back extraction into a salt solution. the strip solution can be the salt of an imaging agent (e.g., Na{sub 4}HEDPA) and thus may, under the appropriate conditions, be injected directly into the human body. {sup 99m}TcO{sub 4}{sup {minus}} can also be concentrated from a dilute load solution of {sup 99}MoO{sub 4}{sup 2{minus}} in NaOH using an aqueous biphasic extraction chromatographic technique (ABEC). A rinse with K{sub 2}CO{sub 3} assures that all {sup 99}MoO{sub 4}{sup 2{minus}} is removed from the column and this is confirmed by a rapid drop in {sup 99}Mo activity by the fourth free column volume (fcv) of rinse. The {sup 99m}TcO{sub 4}{sup {minus}} is then eluted with water. This chromatographic separation affords 94% of the {sup 99m}TcO{sub 4}{sup {minus}} activity in 5 fcv, with the y spectrum showing less than 2 {times} 10{sup {minus}4} of the original {sup 99}Mo activity.
Intensity coding in electric hearing: effects of electrode configurations and stimulation waveforms.
Chua, Tiffany Elise H; Bachman, Mark; Zeng, Fan-Gang
2011-01-01
Current cochlear implants typically stimulate the auditory nerve with biphasic pulses and monopolar electrode configurations. Tripolar stimulation can increase spatial selectivity and potentially improve place pitch related perception but requires higher current levels to elicit the same loudness as monopolar stimulation. The present study combined delayed pseudomonophonasic pulses, which produce lower thresholds, with tripolar stimulation in an attempt to solve the power-performance tradeoff problem. The present study systematically measured thresholds, dynamic range, loudness growth, and intensity discrimination using either biphasic or delayed pseudomonophonasic pulses under both monopolar and tripolar stimulation. Participants were five Clarion cochlear implant users. For each subject, data from apical, middle, and basal electrode positions were collected when possible. Compared with biphasic pulses, delayed pseudomonophonasic pulses increased the dynamic range by lowering thresholds while maintaining comparable maximum allowable levels under both electrode configurations. However, delayed pseudomonophonasic pulses did not change the shape of loudness growth function and actually increased intensity discrimination limens, especially at lower current levels. The present results indicate that delayed pseudomonophonasic pulses coupled with tripolar stimulation cannot provide significant power savings nor can it increase the functional dynamic range. Whether this combined stimulation could improve functional spectral resolution remains to be seen.
International Nuclear Information System (INIS)
Fortin, M.A.; Paynter, R.W.; Sarkissian, A.; Stansfield, B.L.; Terreault, B.; Dufresne, V.
2003-01-01
The development of endovascular brachytherapy and the treatment of certain types of cancers (liver, lung, prostate) often require the use of beta-emitters, sometimes in the form of radioisotope-implanted devices. Among the most commonly used isotopes figures 32 P, a pure beta-emitter (maximum energy: 1.7 MeV), of which the path in biological tissues is of a few cm, restricting the impact of electron bombardment to the immediate environment of the implant. Several techniques and processes have been tried to elaborate surfaces and devices showing strongly bonded, or implanted 32 P. Anodizing, vapor phase deposition, grafting of oligonucleotides, as well as ion implantation processes have been investigated by several research groups as methods to implant beta-radioisotopes into surfaces. A coaxial plasma reactor was developed at INRS to implant radioisotopes into cylindrical metallic objects, such as coronary stents commonly used in angioplasty procedures. The dispersion of 32 P atoms on the interior surfaces of the chamber can be investigated using radiographs, contributing to image the plasma ion transport mechanisms that guide the efficiency of the implantation procedure. The amount of radioactivity on the wall liner, on the internal components, and on the biomedical implants are quantified using a surface barrier detector. A comparative study establishes a relationship between the gray scale of the radiographs, and dose measurements. A program was developed to convert the digitized images into maps showing surface dose density in mCi/cm 2 . An integration process allows the quantification of the doses on the walls and components of the reactor. Finally, the resulting integral of the 32 P dose is correlated to the initial amount of radioactivity inserted inside the implanter before the dismantling procedure. This method could be introduced as a fast and reliable way to test, qualify and assess the amount of radioactivity present on the as-produced implants
Early implant-associated osteomyelitis results in a peri-implanted bacterial reservoir
DEFF Research Database (Denmark)
Jensen, Louise Kruse; Koch, Janne; Aalbæk, Bent
2017-01-01
weight of Staphylococcus aureus or saline was inserted into the right tibial bone of 12 pigs. The animals were consecutively killed on day 2, 4 and 6 following implantation. Bone tissue around the implant was histologically evaluated. Identification of S. aureus was performed immunohistochemically...... on tissue section and with scanning electron microscopy and peptide nucleic acid in situ hybridization on implants. The distance of the peri-implanted pathological bone area (PIBA), measured perpendicular to the implant, was significantly larger in infected animals compared to controls (p = 0...
Stewart, Suzanne; Richardson, Dean; Boston, Ray; Schaer, Thomas P
2015-11-01
To determine (1) survival to discharge of horses with radial fractures (excluding osteochondral fragmentation of the distal aspect of the radius and stress fractures); and (2) risk factors affecting survival to hospital discharge in conservative and surgically managed fractures. Case series. Horses (n = 54). Medical records (1990-June 2012) and radiographs of horses admitted with radial fracture were reviewed. Horses with osteochondral fragmentation of the distal aspect of the radius or stress fractures were excluded. Evaluated risk factors were age, fracture configuration, surgical repair method, surgical duration, hospitalization time, implant failure rate, and surgical site infection (SSI) rate. Of 54 horses, overall survival to discharge was 50%. Thirteen (24%) were euthanatized on admission because of (1) fracture severity; (2) presence of an open fracture; or (3) financial constraints. Fourteen (26%) horses with minimally displaced incomplete fractures were conservatively managed and 12 (86%) survived to discharge. Twenty-seven (50%) horses had surgical treatment by open reduction and internal fixation (ORIF) and 15 (56%) survived to hospital discharge. Open fractures were significantly more likely to develop SSI (P = .008), which also resulted in a 17-fold increase in implant failure (P horses with an open fracture did not survive to discharge. Outcome was also adversely affected by age (P 168 minutes (P fractures is good. Young horses have a good prognosis survival to discharge for ORIF, whereas ORIF in adult horses has a poor prognosis and SSI strongly correlates with catastrophic implant failure. © Copyright 2015 by The American College of Veterinary Surgeons.
Influence of different implant materials on the primary stability of orthodontic mini-implants
Chin-Yun Pan; Szu-Ting Chou; Yu-Chuan Tseng; Yi-Hsin Yang; Chao-Yi Wu; Ting-Hsun Lan; Pao-Hsin Liu; Hong-Po Chang
2012-01-01
This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants w...
Irradiation induces a biphasic expression of pro-inflammatory cytokines in the lung
International Nuclear Information System (INIS)
Ruebe, C.E.; Wilfert, F.; Palm, J.; Burdak-Rothkamm, S.; Ruebe, C.; Koenig, J.; Liu Li; Schuck, A.; Willich, N.
2004-01-01
Background and purpose: the precise pathophysiological mechanisms of radiation-induced lung injury are poorly understood, but have been shown to correlate with dysregulation of different cytokines. The purpose of this study was to evaluate the time course of the pro-inflammatory cytokines tumor necrosis factor-(TNF-)α, interleukin-(IL)-1α and IL-6 after whole-lung irradiation. Material and methods: the thoraces of C57BL/6J mice were irradiated with 12 Gy. Treated and control mice were sacrificed at 0.5, 1, 3, 6, 12, 24, 48, 72 h, 1, 2, 4, 8, 16, and 24 weeks post irradiation (p.i.). Real-time multiplex RT-PCR (reverse transcriptase polmyerase chain reaction) was established to evaluate the expression of TNF-α, IL-1α and IL-6 in the lung tissue of the mice. For histological analysis, lung tissue sections were stained by hematoxylin and eosin. Results: multiplex RT-PCR analysis revealed a biphasic expression of these pro-inflammatory cytokines in the lung tissue after irradiation. After an initial increase at 1 h p.i. for TNF-α and at 6 h p.i. for IL-1α and IL-6, the mRNA expression of these pro-inflammatory cytokines returned to basal levels (48 h, 72 h, 1 week, 2 weeks p.i.). During the pneumonic phase, TNF-α, IL-1α and IL-6 were significantly elevated and revealed their maximum at 8 weeks p.i. Histopathologic evaluation of the lung sections obtained within 4 weeks p.i. revealed only minor lung damage in 5-30% of the lung tissue. By contrast, at 8, 16, and 24 weeks p.i., 70-90% of the lung tissue revealed histopathologically detectable organizing alveolitis. Conclusion: irradiation induces a biphasic expression of pro-inflammatory cytokines in the lung. The initial transitory cytokine response occurred within the first hours after lung irradiation with no detectable histopathologic alterations. The second, more persistent cytokine elevation coincided with the onset of histologically discernible organizing acute pneumonitis. (orig.)
Irradiation induces a biphasic expression of pro-inflammatory cytokines in the lung
Energy Technology Data Exchange (ETDEWEB)
Ruebe, C.E.; Wilfert, F.; Palm, J.; Burdak-Rothkamm, S.; Ruebe, C. [Dept. of Radiotherapy - Radiooncology, Saarland Univ., Homburg/Saar (Germany); Koenig, J. [Inst. of Medical Biometrics, Epidemiology and Medical Informatics, Saarland Univ., Homburg/Saar (Germany); Liu Li [Dept. of Radiotherapy - Radiooncology, Saarland Univ., Homburg/Saar (Germany); Cancer Center, Union Hospital Tongji Medical Coll., Huazhong Univ. of Science and Technology, Wuhan (China); Schuck, A.; Willich, N. [Dept. of Radiotherapy - Radiooncology, Univ. of Muenster (Germany)
2004-07-01
Background and purpose: the precise pathophysiological mechanisms of radiation-induced lung injury are poorly understood, but have been shown to correlate with dysregulation of different cytokines. The purpose of this study was to evaluate the time course of the pro-inflammatory cytokines tumor necrosis factor-(TNF-){alpha}, interleukin-(IL)-1{alpha} and IL-6 after whole-lung irradiation. Material and methods: the thoraces of C57BL/6J mice were irradiated with 12 Gy. Treated and control mice were sacrificed at 0.5, 1, 3, 6, 12, 24, 48, 72 h, 1, 2, 4, 8, 16, and 24 weeks post irradiation (p.i.). Real-time multiplex RT-PCR (reverse transcriptase polmyerase chain reaction) was established to evaluate the expression of TNF-{alpha}, IL-1{alpha} and IL-6 in the lung tissue of the mice. For histological analysis, lung tissue sections were stained by hematoxylin and eosin. Results: multiplex RT-PCR analysis revealed a biphasic expression of these pro-inflammatory cytokines in the lung tissue after irradiation. After an initial increase at 1 h p.i. for TNF-{alpha} and at 6 h p.i. for IL-1{alpha} and IL-6, the mRNA expression of these pro-inflammatory cytokines returned to basal levels (48 h, 72 h, 1 week, 2 weeks p.i.). During the pneumonic phase, TNF-{alpha}, IL-1{alpha} and IL-6 were significantly elevated and revealed their maximum at 8 weeks p.i. Histopathologic evaluation of the lung sections obtained within 4 weeks p.i. revealed only minor lung damage in 5-30% of the lung tissue. By contrast, at 8, 16, and 24 weeks p.i., 70-90% of the lung tissue revealed histopathologically detectable organizing alveolitis. Conclusion: irradiation induces a biphasic expression of pro-inflammatory cytokines in the lung. The initial transitory cytokine response occurred within the first hours after lung irradiation with no detectable histopathologic alterations. The second, more persistent cytokine elevation coincided with the onset of histologically discernible organizing acute
Influence of different implant materials on the primary stability of orthodontic mini-implants.
Pan, Chin-Yun; Chou, Szu-Ting; Tseng, Yu-Chuan; Yang, Yi-Hsin; Wu, Chao-Yi; Lan, Ting-Hsun; Liu, Pao-Hsin; Chang, Hong-Po
2012-12-01
This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm). The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm) and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft(3) trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates(®) device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05). Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success. Copyright © 2012. Published by Elsevier B.V.
Influence of different implant materials on the primary stability of orthodontic mini-implants
Directory of Open Access Journals (Sweden)
Chin-Yun Pan
2012-12-01
Full Text Available This study evaluates the influence of different implant materials on the primary stability of orthodontic mini-implants by measuring the resonance frequency. Twenty-five orthodontic mini-implants with a diameter of 2 mm were used. The first group contained stainless steel mini-implants with two different lengths (10 and 12 mm. The second group included titanium alloy mini-implants with two different lengths (10 and 12 mm and stainless steel mini-implants 10 mm in length. The mini-implants were inserted into artificial bones with a 2-mm-thick cortical layer and 40 or 20 lb/ft3 trabecular bone density at insertion depths of 2, 4, and 6 mm. The resonance frequency of the mini-implants in the artificial bone was detected with the Implomates® device. Data were analyzed by two-way analysis of variance followed by the Tukey honestly significant difference test (α = 0.05. Greater insertion depth resulted in higher resonance frequency, whereas longer mini-implants showed lower resonance frequency values. However, resonance frequency was not influenced by the implant materials titanium alloy or stainless steel. Therefore, the primary stability of a mini-implant is influenced by insertion depth and not by implant material. Insertion depth is extremely important for primary implant stability and is critical for treatment success.
Imaging of common breast implants and implant-related complications: A pictorial essay
Shah, Amisha T; Jankharia, Bijal B
2016-01-01
The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance i...
... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...
Wang, Lie; Chen, Zhi-Yuan; Liu, Rong; Zeng, Hao
2017-08-01
To study the value and satisfaction of three-dimensional printing implant template and conventional implant template in multi-tooth dental implantation. Thirty cases (83 teeth) with missing teeth needing to be implanted were randomly divided into conventional implant template group (CIT group, 15 cases, 42 teeth) and 3D printing implant template group (TDPIT group, 15 cases, 41 teeth). Patients in CIT group were operated by using conventional implant template, while patients in TDPIT group were operated by using three-dimensional printing implant template. The differences of implant neck and tip deviation, implant angle deviation and angle satisfaction between the two groups were compared. The difference of probing depth and bone resorption of implant were compared 1 year after operation between the two groups. The difference of success rate and satisfaction of dental implantation were compared 1 year after operation between the two groups. SPSS19.0 software package was used for statistical analysis. The deviation direction of the neck and the tip in disto-mesial, bucco-palatal, vertical direction and angle of implants in disto-mesial and bucco-palatal direction in TDPIT group were significantly lower than in CIT group (P0.05). The difference of the cumulative success rate in dental implantation at 3 months and 6 months between the two groups were not significant (P>0.05), but the cumulative success rate of TDPIT group was significantly higher than CIT group at 9 months and 1 year (90.48% vs 100%,P=0.043). The patients' satisfaction rate of dental implantation in TDPIT group was significantly higher than in CIT group (86.67% vs 53.33%, P=0.046). Using three-dimensional printing implant template can obtain better accuracy of implant, higher implant success rate and better patients' satisfaction than using conventional implant template. It is suitable for clinical application.
Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.
Depprich, Rita; Zipprich, Holger; Ommerborn, Michelle; Mahn, Eduardo; Lammers, Lydia; Handschel, Jörg; Naujoks, Christian; Wiesmann, Hans-Peter; Kübler, Norbert R; Meyer, Ulrich
2008-11-06
The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level. A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface. Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography. The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.
Taha, Mutasem O; Nasser, Wissam; Ardakani, Adel; Alkhatib, Hatim S
2008-02-28
The aim of this research is to investigate the effects of sodium lauryl sulfate (SLS) on ionotropically cross-linked alginate beads. Different levels of SLS were mixed with sodium alginate and chlorpheniramine maleate (as loaded model drug). The resulting viscous solutions were dropped onto aqueous solutions of zinc or calcium ions for ionotropic curing. The generated beads were assessed by their drug releasing profiles, infrared and differential scanning colorimetery (DSC) traits. SLS was found to exert profound concentration-dependent impacts on the characteristics of zinc-crosslinked alginate beads such that moderate modifications in the levels of SLS switched drug release from enteric coating-like behavior to a biphasic release modifiable to sustained-release by the addition of minute amounts of xanthan gum. Calcium cross-linking failed to reproduce the same behavior, probably due to the mainly ionic nature of calcium-carboxylate bonds compared to the coordinate character of their zinc-carboxylate counterparts. Apparently, moderate levels of SLS repel water penetration into the beads, and therefore minimize chlorpheniramine release. However, higher SLS levels seem to discourage polymeric cross-linking and therefore allow biphasic drug release.
Spindle-cell squamous carcinoma of the esophagus: a tumor with biphasic morphology
International Nuclear Information System (INIS)
Agha, F.P.; Keren, D.F.
1985-01-01
Spindle-cell squamous carcinoma of the esophagus is a rare malignant tumor. It is characterized by a large bulky mass in the middle third of the esophagus with a lobulated surface and local expansion of the esophagus. This lesion may be pedunculated and cause relatively little obstruction despite its bulk. The current view, based on ultrastructure and immunohistochemical evidence, has confirmed that the sarcomatous component of the squamous cell carcinoma originates from mesenchymal metaplasia of squamous cells. On the basis of this evidence and clinical behavior, it seems appropriate to consider carcinosarcoma and pseudosarcoma as equivalents and as variants of squamous cell carcinoma. Four patients with spindle-cell squamous carcinoma, an unusual subset of squamous carcinoma, are described, and the salient radiographic and pathologic features of this disorder's distinctive biphasic morphology are discussed
Mishima, Hajime; Sakai, Shinsuke; Uemura, Toshimasa
2013-01-01
Objective: The purpose of this study was to evaluate the long-term results of cartilage repair after allogeneic transplantation of cartilaginous aggregates formed from bone marrow–derived cells. Methods: Bone marrow cells were harvested from 12-day-old rabbits. The cells were subjected to a monolayer culture, and the spindle-shaped cells attached to the flask surface were defined as bone marrow–derived mesenchymal cells. After the monolayer culture, a 3-dimensional cartilaginous aggregate was formed using a bioreactor with chondrogenesis. We created osteochondral defects, measuring 5 mm in diameter and 4 mm in depth, at the femoral trochlea of 10-week-old rabbits. Two groups were established, the transplanted group in which the cartilaginous aggregate was transplanted into the defect, and the control group in which the defect was left untreated. Twenty-six and 52 weeks after surgery, the rabbits were sacrificed and their tissue repair status was evaluated macroscopically (International Cartilage Repair Society [ICRS] score) and histologically (O’Driscoll score). Results: The ICRS scores were as follows: at week 26, 7.2 ± 0.5 and 7.6 ± 0.8; at week 52, 7.6 ± 1.1 and 9.7 ± 0.7, for the transplanted and control groups, respectively. O’Driscoll scores were as follows: at week 26, 12.6 ± 1.9 and 10.1 ± 1.9; at week 52, 9.6 ± 3.0 and 14.0 ± 1.4, each for transplanted and control groups, respectively. No significant differences were observed between the groups. Conclusions: This study demonstrates that allogeneic transplantation of cartilaginous aggregates formed from bone marrow–derived cells produces comparable long-term results based on macroscopic and histological outcome measures when compared with osteochondral defects that are left untreated. PMID:26069678
Yoshioka, Tomokazu; Mishima, Hajime; Sakai, Shinsuke; Uemura, Toshimasa
2013-10-01
The purpose of this study was to evaluate the long-term results of cartilage repair after allogeneic transplantation of cartilaginous aggregates formed from bone marrow-derived cells. Bone marrow cells were harvested from 12-day-old rabbits. The cells were subjected to a monolayer culture, and the spindle-shaped cells attached to the flask surface were defined as bone marrow-derived mesenchymal cells. After the monolayer culture, a 3-dimensional cartilaginous aggregate was formed using a bioreactor with chondrogenesis. We created osteochondral defects, measuring 5 mm in diameter and 4 mm in depth, at the femoral trochlea of 10-week-old rabbits. Two groups were established, the transplanted group in which the cartilaginous aggregate was transplanted into the defect, and the control group in which the defect was left untreated. Twenty-six and 52 weeks after surgery, the rabbits were sacrificed and their tissue repair status was evaluated macroscopically (International Cartilage Repair Society [ICRS] score) and histologically (O'Driscoll score). The ICRS scores were as follows: at week 26, 7.2 ± 0.5 and 7.6 ± 0.8; at week 52, 7.6 ± 1.1 and 9.7 ± 0.7, for the transplanted and control groups, respectively. O'Driscoll scores were as follows: at week 26, 12.6 ± 1.9 and 10.1 ± 1.9; at week 52, 9.6 ± 3.0 and 14.0 ± 1.4, each for transplanted and control groups, respectively. No significant differences were observed between the groups. This study demonstrates that allogeneic transplantation of cartilaginous aggregates formed from bone marrow-derived cells produces comparable long-term results based on macroscopic and histological outcome measures when compared with osteochondral defects that are left untreated.
A Fast Method for Measuring Psychophysical Thresholds Across the Cochlear Implant Array
Directory of Open Access Journals (Sweden)
Julie A. Bierer
2015-02-01
Full Text Available A rapid threshold measurement procedure, based on Bekesy tracking, is proposed and evaluated for use with cochlear implants (CIs. Fifteen postlingually deafened adult CI users participated. Absolute thresholds for 200-ms trains of biphasic pulses were measured using the new tracking procedure and were compared with thresholds obtained with a traditional forced-choice adaptive procedure under both monopolar and quadrupolar stimulation. Virtual spectral sweeps across the electrode array were implemented in the tracking procedure via current steering, which divides the current between two adjacent electrodes and varies the proportion of current directed to each electrode. Overall, no systematic differences were found between threshold estimates with the new channel sweep procedure and estimates using the adaptive forced-choice procedure. Test–retest reliability for the thresholds from the sweep procedure was somewhat poorer than for thresholds from the forced-choice procedure. However, the new method was about 4 times faster for the same number of repetitions. Overall the reliability and speed of the new tracking procedure provides it with the potential to estimate thresholds in a clinical setting. Rapid methods for estimating thresholds could be of particular clinical importance in combination with focused stimulation techniques that result in larger threshold variations between electrodes.
Biphasic oxidation of oxy-hemoglobin in bloodstains.
Directory of Open Access Journals (Sweden)
Rolf H Bremmer
Full Text Available BACKGROUND: In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO(2 to met-hemoglobin (met-Hb and hemichrome (HC. The fractions of HbO(2, met-Hb and HC in a bloodstain can be used for age determination of bloodstains. In this study, we further analyze the conversion of HbO(2 to met-Hb and HC, and determine the effect of temperature and humidity on the conversion rates. METHODOLOGY: The fractions of HbO(2, met-Hb and HC in a bloodstain, as determined by quantitative analysis of optical reflectance spectra (450-800 nm, were measured as function of age, temperature and humidity. Additionally, Optical Coherence Tomography around 1300 nm was used to confirm quantitative spectral analysis approach. CONCLUSIONS: The oxidation rate of HbO(2 in bloodstains is biphasic. At first, the oxidation of HbO(2 is rapid, but slows down after a few hours. These oxidation rates are strongly temperature dependent. However, the oxidation of HbO(2 seems to be independent of humidity, whereas the transition of met-Hb into HC strongly depends on humidity. Knowledge of these decay rates is indispensable for translating laboratory results into forensic practice, and to enable bloodstain age determination on the crime scene.
Directory of Open Access Journals (Sweden)
Vasco Manuel Nobre de Carvalho da Silva Vieira
Full Text Available Isomorphic biphasic algal life cycles often occur in the environment at ploidy abundance ratios (Haploid:Diploid different from 1. Its spatial variability occurs within populations related to intertidal height and hydrodynamic stress, possibly reflecting the niche partitioning driven by their diverging adaptation to the environment argued necessary for their prevalence (evolutionary stability. Demographic models based in matrix algebra were developed to investigate which vital rates may efficiently generate an H:D variability at a fine spatial resolution. It was also taken into account time variation and type of life strategy. Ploidy dissimilarities in fecundity rates set an H:D spatial structure miss-fitting the ploidy fitness ratio. The same happened with ploidy dissimilarities in ramet growth whenever reproductive output dominated the population demography. Only through ploidy dissimilarities in looping rates (stasis, breakage and clonal growth did the life cycle respond to a spatially heterogeneous environment efficiently creating a niche partition. Marginal locations were more sensitive than central locations. Related results have been obtained experimentally and numerically for widely different life cycles from the plant and animal kingdoms. Spore dispersal smoothed the effects of ploidy dissimilarities in fertility and enhanced the effects of ploidy dissimilarities looping rates. Ploidy dissimilarities in spore dispersal could also create the necessary niche partition, both over the space and time dimensions, even in spatial homogeneous environments and without the need for conditional differentiation of the ramets. Fine scale spatial variability may be the key for the prevalence of isomorphic biphasic life cycles, which has been neglected so far.
Energy Technology Data Exchange (ETDEWEB)
Zwipp, H. (Medizinische Hochschule Hannover (Germany). Unfallchirurgische Klinik)
1991-12-01
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with concomitant compartment syndrome an emergency CT scan can be helpful to determine the optimal surgical approach. In these cases a 3-D reconstruction also might be of assistance. If there is evidence of partial or total talar necrosis, magnetic resonance imaging can be extremely helpful. However, in most cases implants considerably limit the validity of the image obtained. Ultrasonography offers a noninvasive, reproducible, and very inexpensive alternative and should be performed in cases of chondral-osteochondral talar rim avulsions and juvenile osteochondral ligament ruptures. It can also be used as a dynamic method for stress examination in fibular ligament ruptures and soft tissue injuries such as dislocation of the peroneal tendons. The use of arthrography, stress-tenography, and arthro-CT scan nowadays has become extremely limited. (orig.).
Injuries of the tibio-talar joint and preoperative planning
International Nuclear Information System (INIS)
Zwipp, H.
1991-01-01
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with concomitant compartment syndrome an emergency CT scan can be helpful to determine the optimal surgical approach. In these cases a 3-D reconstruction also might be of assistance. If there is evidence of partial or total talar necrosis, magnetic resonance imaging can be extremely helpful. However, in most cases implants considerably limit the validity of the image obtained. Ultrasonography offers a noninvasive, reproducible, and very inexpensive alternative and should be performed in cases of chondral-osteochondral talar rim avulsions and juvenile osteochondral ligament ruptures. It can also be used as a dynamic method for stress examination in fibular ligament ruptures and soft tissue injuries such as dislocation of the peroneal tendons. The use of arthrography, stress-tenography, and arthro-CT scan nowadays has become extremely limited. (orig.) [de
Influence of controlled immediate loading and implant design on peri-implant bone formation.
Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke
2007-02-01
Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (pimplant contact occurred was the highest for SL and significantly different from SU (pimplant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.
Mizutani, Nobuaki; Nabe, Takeshi; Shimazu, Masaji; Yoshino, Shin; Kohno, Shigekatsu
2012-03-01
Ganoderma lucidum (GL), an oriental medical mushroom, has been used in Asia for the prevention and treatment of a variety of diseases. However, the effect of GL on allergic rhinitis has not been well defined. The current study describes the inhibitory effect of GL on the biphasic nasal blockage and nasal hyperresponsiveness induced by repeated antigen challenge in a guinea pig model of allergic rhinitis. Intranasally sensitized guinea pigs were repeatedly challenged by inhalation of Japanese cedar pollen once every week. Ganoderma lucidum was orally administered once daily for 8 weeks from the time before the first challenge. The treatment with GL dose-dependently inhibited the early and late phase nasal blockage at the fifth to ninth antigen challenges. Furthermore, nasal hyperresponsiveness to intranasally applied leukotriene D₄ on 2 days after the eighth antigen challenge was also inhibited by the treatment with GL. However, Cry j 1-specific IgE antibody production was not affected by the treatment. In conclusion, we demonstrated that the pollen-induced biphasic nasal blockage and nasal hyperresponsiveness were suppressed by the daily treatment with GL in the guinea pig model of allergic rhinitis. These results suggest that GL may be a useful therapeutic drug for treating patients with allergic rhinitis. Copyright © 2011 John Wiley & Sons, Ltd.
Magnesium-Based Absorbable Metal Screws for Intra-Articular Fracture Fixation
Directory of Open Access Journals (Sweden)
Roland Biber
2016-01-01
Full Text Available MAGNEZIX® (Syntellix AG, Hanover, Germany is a biodegradable magnesium-based alloy (MgYREZr which is currently used to manufacture bioabsorbable compression screws. To date, there are very few studies reporting on a limited number of elective foot surgeries using this innovative implant. This case report describes the application of this screw for osteochondral fracture fixation at the humeral capitulum next to a loose radial head prosthesis, which was revised at the same time. The clinical course was uneventful. Degradation of the magnesium alloy did not interfere with fracture healing. Showing an excellent clinical result and free range-of-motion, the contour of the implant was still visible in a one-year follow-up.
Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba
2017-12-01
The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.
Mountris, K. A.; Bert, J.; Noailly, J.; Rodriguez Aguilera, A.; Valeri, A.; Pradier, O.; Schick, U.; Promayon, E.; Gonzalez Ballester, M. A.; Troccaz, J.; Visvikis, D.
2017-03-01
Prostate volume changes due to edema occurrence during transperineal permanent brachytherapy should be taken under consideration to ensure optimal dose delivery. Available edema models, based on prostate volume observations, face several limitations. Therefore, patient-specific models need to be developed to accurately account for the impact of edema. In this study we present a biomechanical model developed to reproduce edema resolution patterns documented in the literature. Using the biphasic mixture theory and finite element analysis, the proposed model takes into consideration the mechanical properties of the pubic area tissues in the evolution of prostate edema. The model’s computed deformations are incorporated in a Monte Carlo simulation to investigate their effect on post-operative dosimetry. The comparison of Day1 and Day30 dosimetry results demonstrates the capability of the proposed model for patient-specific dosimetry improvements, considering the edema dynamics. The proposed model shows excellent ability to reproduce previously described edema resolution patterns and was validated based on previous findings. According to our results, for a prostate volume increase of 10-20% the Day30 urethra D10 dose metric is higher by 4.2%-10.5% compared to the Day1 value. The introduction of the edema dynamics in Day30 dosimetry shows a significant global dose overestimation identified on the conventional static Day30 dosimetry. In conclusion, the proposed edema biomechanical model can improve the treatment planning of transperineal permanent brachytherapy accounting for post-implant dose alterations during the planning procedure.
Energy Technology Data Exchange (ETDEWEB)
Huang, Li [Guangxi Key Laboratory of Regenerative Medicine, Guangxi Medical University, Nanning (China); Department of Orthopaedic Trauma and Hand Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning (China); Zhou, Bo; Wu, Huayu [Department of Cell Biology & Genetics, School of Premedical Sciences, Guangxi Medical University, Nanning (China); Zheng, Li, E-mail: zhengli224@163.com [Guangxi Key Laboratory of Regenerative Medicine, Guangxi Medical University, Nanning (China); The Medical and Scientific Research Center, Guangxi Medical University, Nanning (China); Zhao, Jinmin, E-mail: zhaojinmin@126.com [Guangxi Key Laboratory of Regenerative Medicine, Guangxi Medical University, Nanning (China); Department of Orthopaedic Trauma and Hand Surgery, The First Affiliated Hospital of Guangxi Medical University, Nanning (China); Guangxi Colleges and Universities Key Laboratory of Regenerative Medicine, Guangxi Medical University, Nanning (China)
2017-01-01
Although biphasic calcium phosphate ceramic (BCP) holds promise in therapy of bone defect, surface mineralization prior to implantation may improve the bioactivity to better integrate with the host. Immersion in simulated body fluid (SBF) and bovine serum albumin-simulated body fluid (BSA-SBF) are common methods to form apatite interface layer. This study was intended to investigate the effect of SBF and BSA-SBF treatment on the bioactivity of BCP in vitro. In this study, osteoblasts were grown on BCP with or without treatment of SBF or BSA-SBF, and detected with general observation, scanning electron microscope (SEM), cell proliferation assay, morphology observation, viability assay, alkaline phosphatase (ALP) activity assay, and osteogenic specific gene expression of alkaline phosphatase (ALPL), bone gamma-carboxyglutamate (gla) protein (BGLAP), bone morphogenetic protein 2 (BMP2), bone sialoprotein (BSP), type I collagen (COLI) and runt-related transcription factor 2 (RUNX2) after culture of 2, 5 and 8 days. As the results shown, BCP pre-incubated in SBF and BSA-SBF up-regulated ALP activity and osteogenic related genes and proteins, which testified the positive effect of SBF and BSA-SBF. Especially, BSA-SBF enhanced the cell growth significantly. This study indicated that treatment by BSA-SBF is of importance for BCP before clinical application. - Highlights: • BCP pre-incubated in SBF and BSA-SBF significantly promoted osteogenic differetiation of osteoblasts. • BSA-SBF enhanced the cell growth more significantly than SBF. • SBF may be a little toxic to osteoblasts.
Fresh osteochondral allograft transplantation for isolated patellar cartilage injury.
Gracitelli, Guilherme C; Meric, Gokhan; Pulido, Pamela A; Görtz, Simon; De Young, Allison J; Bugbee, William D
2015-04-01
The treatment of patellofemoral cartilage injuries can be challenging. Osteochondral allograft (OCA) transplantation has been used as a treatment option for a range of cartilage disorders. To evaluate functional outcomes and survivorship of the grafts among patients who underwent OCA for patellar cartilage injuries. Case series; Level of evidence, 4. An institutional review board-approved OCA database was used to identify 27 patients (28 knees) who underwent isolated OCA transplantation of the patella between 1983 and 2010. All patients had a minimum 2-year follow-up. The mean age of the patients was 33.7 years (range, 14-64 years); 54% were female. Twenty-six (92.9%) knees had previous surgery (mean, 3.2 procedures; range, 1-10 procedures). The mean allograft area was 10.1 cm(2) (range, 4.0-18.0 cm(2)). Patients returned for clinical evaluation or were contacted via telephone for follow-up. The number and type of reoperations were assessed. Any reoperation resulting in removal of the allograft was considered a failure of the OCA transplantation. Patients were evaluated pre- and postoperatively using the modified Merle d'Aubigné-Postel (18-point) scale, the International Knee Documentation Committee (IKDC) pain, function, and total scores, and the Knee Society function (KS-F) score. Patient satisfaction was assessed at latest follow-up. Seventeen of the 28 knees (60.7%) had further surgery after the OCA transplantation; 8 of the 28 knees (28.6%) were considered OCA failures (4 conversions to total knee arthroplasty, 2 conversions to patellofemoral knee arthroplasty, 1 revision OCA, 1 patellectomy). Patellar allografting survivorship was 78.1% at 5 and 10 years and 55.8% at 15 years. Among the 20 knees (71.4%) with grafts in situ, the mean follow-up duration was 9.7 years (range, 1.8-30.1 years). Pain and function improved from the preoperative visit to latest follow-up, and 89% of patients were extremely satisfied or satisfied with the results of the OCA
CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES
Directory of Open Access Journals (Sweden)
Carolina Damayanti Marpaung
2015-06-01
Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.
Energy Technology Data Exchange (ETDEWEB)
Battaglia, M., E-mail: milva.battaglia@ior.it [Service of Ecography and Radiology, Rizzoli Orthopaedic Institute, via Pupilli n. 1, 40136 Bologna (Italy); Rimondi, E. [Service of Ecography and Radiology, Rizzoli Orthopaedic Institute, via Pupilli n. 1, 40136 Bologna (Italy); Monti, C. [Service of CT and MRI, Casa di Cura Madre Fortunata Toniolo, Bologna (Italy); Guaraldi, F. [Department of Pathology, The Johns Hopkins University, School of Medicine, Baltimore, MD (United States); Sant' Andrea, A. [Service of CT and MRI, Casa di Cura Madre Fortunata Toniolo, Bologna (Italy); Buda, R.; Cavallo, M.; Giannini, S.; Vannini, F. [Clinical Orthopaedic and Traumatology Unit II, Rizzoli Orthopaedic Institute, Bologna (Italy)
2011-11-15
Objective: Bone marrow derived cell transplantation (BMDCT) has been recently suggested as a possible surgical technique to repair osteochondral lesions. To date, no qualitative MRI studies have evaluated its efficacy. The aim of our study is to investigate the validity of MRI T2-mapping sequence in characterizing the reparative tissue obtained and its ability to correlate with clinical results. Methods and materials: 20 patients with an osteochondral lesion of the talus underwent BMDCT and were evaluated at 2 years follow up using MRI T2-mapping sequence. 20 healthy volunteers were recruited as controls. MRI images were acquired using a protocol suggested by the International Cartilage Repair Society, MOCART scoring system and T2 mapping. Results were then correlated with AOFAS clinical score. Results: AOFAS score increased from 66.8 {+-} 14.5 pre-operatively to 91.2 {+-} 8.3 (p < 0.0005) at 2 years follow-up. T2-relaxation time value of 35-45 ms was derived from healthy ankles evaluation and assumed as normal hyaline cartilage value and used as a control. Regenerated tissue with a T2-relaxation time value comparable to hyaline cartilage was found in all the cases treated, covering a mean of 78% of the repaired lesion area. A high clinical score was related directly to isointense signal in DPFSE fat sat (p = 0.05), and percentage of regenerated hyaline cartilage (p = 0.05), inversely to the percentage of regenerated fibrocartilage. Lesion's depth negatively related to the integrity of the repaired tissue's surface (tau = -0.523, p = 0.007), and to the percentage of regenerated hyaline cartilage (rho = -0.546, p = 0.013). Conclusions: Because of its ability to detect cartilage's quality and to correlate to the clinical score, MRI T2-mapping sequence integrated with Mocart score represent a valid, non-invasive technique for qualitative cartilage assessment after regenerative surgical procedures.
Psychological intervention following implantation of an implantable defibrillator
DEFF Research Database (Denmark)
Pedersen, Susanne S.; van den Broek, Krista C; Sears, Samuel F
2007-01-01
The medical benefits of the implantable cardioverter defibrillator (ICD) are unequivocal, but a subgroup of patients experiences emotional difficulties following implantation. For this subgroup, some form of psychological intervention may be warranted. This review provides an overview of current ...
Directory of Open Access Journals (Sweden)
Nicolò Cavalli
2015-01-01
Full Text Available Objectives. The aim of this retrospective study was to assess the incidence and prevalence of peri-implant mucositis and peri-implantitis in patients with a fixed full-arch prosthesis supported by two axial and two tilted implants. Materials and Methods. Sixty-nine patients were included in the study. Each patient received a fixed full-arch prosthesis supported by two mesial axial and two distal tilted implants to rehabilitate the upper arch, the lower arch, or both. Three hundred thirty-six implants for 84 restorations were delivered. Patients were scheduled for follow-up visits every 6 months in the first 2 years and yearly after. At each follow-up visit peri-implant mucositis and peri-implantitis were diagnosed if present. Results. The overall follow-up range was from 12 to 130 months (mean 63,2 months. Three patients presented peri-implantitis. The prevalence of peri-implant mucositis ranged between 0 and 7,14% of patients (5,06% of implants while the prevalence of peri-implantitis varied from 0 to 4,55% of patients (3,81% of implants. Conclusions. The prevalence and incidence of peri-implant mucositis and peri-implantitis are lower than most of the studies in literature. Therefore this kind of rehabilitation could be considered a feasible option, on the condition of adopting a systematic hygienic protocol.
A new system of implant abutment connection: how to improve a two piece implant system sealing.
Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F
2017-01-01
Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.
Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.
Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior
2018-01-01
Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.
International Nuclear Information System (INIS)
Sato, Susumu
1994-01-01
The graphitization and the change to amorphous state of diamond surface layer by ion implantation and its characteristics are reported. In the diamond surface, into which more than 10 16 ions/cm 2 was implanted, the diamond crystals are broken, and the structure changes to other carbon structure such as amorphous state or graphite. Accompanying this change of structure, the electric conductivity of the implanted layer shows two discontinuous values due to high resistance and low resistance. This control of structure can be done by the temperature of the base during the ion implantation into diamond. Also it is referred to that by the base temperature during implantation, the mutual change of the structure between amorphous state and graphite can be controlled. The change of the electric resistance and the optical characteristics by the ion implantation into diamond surface, the structural analysis by Raman spectroscopy, and the control of the structure of the implanted layer by the base temperature during implantation are reported. (K.I.)
Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K
2018-03-18
To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.
Biphasic insulin-releasing effect of BTS 67 582 in rats.
Storey, D A; Bailey, C J
1998-12-01
BTS 67 582 (1,1-dimethyl-2(2-morpholinophenyl)guanidine fumarate) is being developed as a short-acting anti-diabetic insulin secretagogue. The effect of BTS 67 582 on the phasic pattern of insulin release was assessed in anaesthetized normal rats by measuring arterial plasma insulin concentrations while arterial glucose concentrations were fixed at 6, 8.5 and 12.5 mM. Intravenous BTS 67 582 (10 mg kg(-1)) induced an immediate but transient increase in insulin concentrations which declined by 10 min (first phase). This was followed by a smaller but sustained increase in insulin concentrations (second phase). The increment from basal to peak insulin release (0-2 min) was independent of glucose, but the first phase was maintained for longer and the second phase was greater at the highest concentration of glucose (12.5 mM). BTS 67 582 also extended the first-phase insulin response to a standard intravenous glucose challenge and enhanced the rate of glucose disappearance by approximately 12%. Thus BTS 67 582 causes biphasic stimulation of insulin release and augments the insulin-releasing effect of glucose.
Impact of cone-beam computed tomography on implant planning and on prediction of implant size
Energy Technology Data Exchange (ETDEWEB)
Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral
2013-11-15
The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)
Metals for bone implants. Part 1. Powder metallurgy and implant rendering.
Andani, Mohsen Taheri; Shayesteh Moghaddam, Narges; Haberland, Christoph; Dean, David; Miller, Michael J; Elahinia, Mohammad
2014-10-01
New metal alloys and metal fabrication strategies are likely to benefit future skeletal implant strategies. These metals and fabrication strategies were looked at from the point of view of standard-of-care implants for the mandible. These implants are used as part of the treatment for segmental resection due to oropharyngeal cancer, injury or correction of deformity due to pathology or congenital defect. The focus of this two-part review is the issues associated with the failure of existing mandibular implants that are due to mismatched material properties. Potential directions for future research are also studied. To mitigate these issues, the use of low-stiffness metallic alloys has been highlighted. To this end, the development, processing and biocompatibility of superelastic NiTi as well as resorbable magnesium-based alloys are discussed. Additionally, engineered porosity is reviewed as it can be an effective way of matching the stiffness of an implant with the surrounding tissue. These porosities and the overall geometry of the implant can be optimized for strain transduction and with a tailored stiffness profile. Rendering patient-specific, site-specific, morphology-specific and function-specific implants can now be achieved using these and other metals with bone-like material properties by additive manufacturing. The biocompatibility of implants prepared from superelastic and resorbable alloys is also reviewed. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Charles Oluwaseun ADETUNJI; Julius Kola OLOKE; Gandham PRASAD; Moses ABALAKA; Emenike Onyebum IROKANULO
2017-01-01
Formulation of effective and environmental friendly bioherbicides depends on the type of fermentation medium used for the production of phytotoxic metabolites. The effect of biomass, colony forming unit and the phytotoxic metabolite produced from the biphasic fermentation was carried out, while the phytotoxic metabolite was tested in vivo and in-vitro on Echinochola crus-galli and dicotyledonous Chromolaena odorata. The mutant strain of Lasiodiplodia pseudotheobromae C1136 (Lp90) produced th...
Sivan-Gildor, Adi; Machtei, Eli E; Gabay, Eran; Frankenthal, Shai; Levin, Liran; Suzuki, Marcelo; Coelho, Paulo G; Zigdon-Giladi, Hadar
2014-10-01
The primary aim is to evaluate clinical, radiographic, and histologic parameters of novel implants with "three roots" design that were inserted into fresh multirooted extraction sockets. A secondary aim is to compare this new implant to standard root-form dental implants. Immediate implantation of novel or standard design 6 × 6-mm implants was performed bilaterally into multirooted sockets in mandibles of mini-pigs. Twelve weeks later, clinical, radiographic, stability, histomorphometric, and microcomputed tomography (micro-CT) analyses were performed. Survival rates were significantly higher in the test implants compared with control (92.8% versus 33.3%, respectively; P micro-CT analyses demonstrated bone fill in the inner part of the test implants. Moreover, bone-to-implant contact was higher in the test implants (55.50% ± 3.68% versus 42.47% ± 9.89%). Contrary to the clinical, radiographic, and histomorphometric results, resonance frequency analysis measurements were greater in the control group (77.74 ± 3.21 implant stability quotient [ISQ]) compared with the test group (31.09 ± 0.28 ISQ), P = 0.008. The novel design implants resulted in significantly greater survival rate in multirooted extraction sites. Further studies will be required to validate these findings.
Ivanovski, Saso
2015-01-01
1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.
Structure of ion-implanted ceramics
International Nuclear Information System (INIS)
Naramoto, Hiroshi
1983-01-01
The variation of structure of LiF, MgO, Al 2 O 3 and TiO 2 accompanying annealing after ion implantation is explained. The analysis of structure is usually made by the perturbed gamma ray angular correlation, the internal electron Moessbauer method, or the ion scattering method. The results of analyses are discussed for alkali ion implantation, Fe-ion implantation, In-ion implantation, Au-ion implantation, Pt-ion implantation, Pb-ion implantation and transition metal ion implantation. The coupling of the implanted elements with lattice defects and matrix elements, and the compatibility between deposited elements and matrix crystal lattice were studied. The variation of physical properties due to ion implantation such as phase transition, volume change, the control of single crystal region, and the variation of hardness near surface were investigated, and the examples are presented. (Kato, T.)
Biphasic {sup 68}Ga-PSMA-HBED-CC-PET/CT in patients with recurrent and high-risk prostate carcinoma
Energy Technology Data Exchange (ETDEWEB)
Sahlmann, Carsten-Oliver; Meller, Birgit; Bouter, Caroline; Meller, Johannes [University Medical Center Goettingen, Department of Nuclear Medicine, Goettingen (Germany); Ritter, Christian Oliver; Lotz, Joachim [University Medical Center Goettingen, Department of Diagnostic and Interventional Radiology, Goettingen (Germany); Stroebel, Philipp [University Medical Center Goettingen, Department of Pathology, Goettingen (Germany); Trojan, Lutz; Hijazi, Sameh [University Medical Center Goettingen, Department of Urology, Goettingen (Germany)
2016-05-15
Binding of {sup 68}Ga-PSMA-HBED-CC ({sup 68}Ga-PSMA) at prostate cancer (PC) cells increases over time. A biphasic protocol may help separating benign from tumor lesions. The aim of this study was the retrospective evaluation of a diagnostic incremental value of a dual-time point (biphasic) {sup 68}Ga-PSMA-PET/CT in patients with prostate cancer. Retrospective analysis of 35 consecutive patients (49-78 years, median 71) with newly diagnosed PC (12/35) or recurrence of PC (23/35). PET/CT (Gemini TF16, Philips) was acquired 1 h and 3 h p. i. of 140-392 MBq (300 MBq median) {sup 68}Ga-PSMA, followed by a diagnostic contrast CT. PET findings were correlated with histology or unequivocal CT findings. Semiquantitative PET data (SUVmax, SUV mean) were acquired and target-to-background-ratios (T/B-ratio) were calculated for benign and malign lesions for both time points. Size of lymph nodes (LN) on diagnostic CT was recorded. Statistical analysis was performed for assessment of significant changes of semiquantitative PET-parameters over time and for correlation of size and uptake of lymph nodes. One hundred and four lesions were evaluated. Sixty lesions were referenced by histology or unequivocal CT findings, including eight (13.3 %) histopathologically benign lymph nodes, 12 (20 %) histopathologically lymph node metastases, 12 (20 %) primary tumors, three (5 %) local recurrences, and 25 (41.7 %) bone metastases. Forty-four lesions were axillary LN with normal CT-appearance. Benign lesions had significantly lower SUVmax and T/B-ratios compared with malignant findings. Malign lesions showed a significant increase of both parameters over time compared to benign findings. There was no correlation between LN size and SUVmax. The sensitivity, specificity, the positive predictive value and negative predictive value of PET/CT regarding pelvic LN was 94 %, 99 %, 89 %, and 99.5 %, respectively. In contrast to benign tissues, the uptake of proven tumor lesions increases on {sup 68
Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G
2005-01-01
Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap
Aqueous biphasic systems involving alkylsulfate-based ionic liquids
Energy Technology Data Exchange (ETDEWEB)
Deive, Francisco J. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Rodriguez, Ana [Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Marrucho, Isabel M., E-mail: imarrucho@itqb.unl.pt [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Rebelo, Luis P.N. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal)
2011-11-15
Highlights: > K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4} act as phase promoter in aqueous solutions of ILs. > Remarkable influence of alkyl-chain length on solubility curves of alkylsulfate-based ILs. > Merchuck correlation was used for describing these systems. > {Delta}S{sub hyd} and Hofmeister series were used to discuss the different salting out effects. - Abstract: The specific effects of K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4}, as high charge-density inorganic salts and thus inducers of the formation of aqueous biphasic systems (ABS) containing several ethyl-methylimidazolium alkylsulfate ionic liquids, C{sub 2}MIM C{sub n}SO{sub 4} (n = 2, 4, 6, or 8), have been assessed at T = 298.15 K. The results are analyzed in the light of the Hofmeister series. The influence of different alkyl chain lengths in the anion, together with the ability of the selected inorganic salts to induce the formation of ABS, is discussed. Phase diagrams have been determined through turbidimetry, including tie lines assignments from mass phase ratios according to the lever - arm rule. The Merchuck equation was satisfactorily used to correlate the solubility curve.
Downey, DF; Jones, KS; Ryding, G
1993-01-01
Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach
Individual titanium zygomatic implant
Nekhoroshev, M. V.; Ryabov, K. N.; Avdeev, E. V.
2018-03-01
Custom individual implants for the reconstruction of craniofacial defects have gained importance due to better qualitative characteristics over their generic counterparts – plates, which should be bent according to patient needs. The Additive Manufacturing of individual implants allows reducing cost and improving quality of implants. In this paper, the authors describe design of zygomatic implant models based on computed tomography (CT) data. The fabrication of the implants will be carried out with 3D printing by selective laser melting machine SLM 280HL.
A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.
Bryant, S R; Walton, J N; MacEntee, M I
2015-01-01
The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.
Recent advances in dental implants.
Hong, Do Gia Khang; Oh, Ji-Hyeon
2017-12-01
Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.
Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz
2016-06-01
Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.
Ballo, Ahmed M; Akca, Eralp; Ozen, Tuncer; Moritz, Niko; Lassila, Lippo; Vallittu, Pekka; Närhi, Timo
2014-08-01
This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants. © 2014 Eur J Oral Sci.
Stoichiometric implications of a biphasic life cycle.
Tiegs, Scott D; Berven, Keith A; Carmack, Douglas J; Capps, Krista A
2016-03-01
Animals mediate flows of elements and energy in ecosystems through processes such as nutrient sequestration in body tissues, and mineralization through excretion. For taxa with biphasic life cycles, the dramatic shifts in anatomy and physiology that occur during ontogeny are expected to be accompanied by changes in body and excreta stoichiometry, but remain little-explored, especially in vertebrates. Here we tested stoichiometric hypotheses related to the bodies and excreta of the wood frog (Lithobates sylvaticus) across life stages and during larval development. Per-capita rates of nitrogen (N) and phosphorus (P) excretion varied widely during larval ontogeny, followed unimodal patterns, and peaked midway through development (Taylor-Kollros stages XV and XII, respectively). Larval mass did not increase steadily during development but peaked at stage XVII and declined until the termination of the experiment at stage XXII. Mass-specific N and P excretion rates of the larvae decreased exponentially during development. When coupled with population-biomass estimates, population-level excretion rates were greatest at stages VIII-X. Percent carbon (C), N, and C:N of body tissue showed weak trends across major life stages; body P and C:P, however, increased sixfold during development from egg to adult. Our results demonstrate that intraspecific ontogenic changes in nutrient contents of excretion and body tissues can be significant, and that N and P are not always excreted proportionally throughout life cycles. These results highlight the dynamic roles that species play in ecosystems, and how the morphological and physiological changes that accompany ontogeny can influence ecosystem-level processes.
Directory of Open Access Journals (Sweden)
Juan Carlos Vanegas Acosta
2010-03-01
Full Text Available La osteointegración es la conexión estructural y funcional entre el hueso y un implante. Cuando un implante se inserta en el hueso, se crea la denominada interfase hueso-implante, una zona de unión entre la superficie del biomaterial del implante y el hueso circundante. La cicatrización de esta interfase depende de las condiciones biológicas del hueso, las características de diseño del implante y la distribución de cargas entre hueso e implante. En este artículo se hace una revisión del proceso de cicatrización de la interfase hueso-implante para el caso de un implante dental. El objetivo es describir la secuencia de eventos biológicos iniciados con la lesión causada por la inserción del implante y que concluyen con la formación de nuevo hueso en la interfase. Esta descripción incluye una novedosa clasificación de los fenómenos mecánicos que intervienen durante el proceso de cicatrización de los tejidos lesionados. Esta descripción mecanobiológica de la interfase hueso-implante dental se utiliza para determinar las características más relevantes a tener en cuenta en la formulación de un modelo matemático de la osteointegración de implantes dentales.The osteointegration is the structural and functional connection between bone and implant. When an implant is inserted in bone, it creates the so-called bone-implant interphase, a joint zone between implant biomaterial surface and the surrounding bone. The healing of this interphase depends on bone biological conditions, characteristic of implant design and the distribution of loads between bone and implant. The aim of present article is to review of healing process of bone-implant interphase for a dental implant and also to describe the sequence of biological events beginning with lesion caused by implant insertion and leading to the formation of a new bone in the interphase. This description includes a novel classification of mechanical phenomena present in the healing
... implant, including: How long a person has been deaf, The number of surviving auditory nerve fibers, and ... Implant, Severe Sensoryneurial Hearing Loss Get Involved Professional Development Practice Management ENT Careers Marketplace Privacy Policy Terms ...
The clinical implications of poly implant prothèse breast implants: an overview.
Wazir, Umar; Kasem, Abdul; Mokbel, Kefah
2015-01-01
Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.
The Clinical Implications of Poly Implant Prothèse Breast Implants: An Overview
Directory of Open Access Journals (Sweden)
Umar Wazir
2015-01-01
Full Text Available Mammary implants marketed by Poly Implant Prothèse (PIP were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635 for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.
Cui, Haitao; Zhu, Wei; Nowicki, Margaret; Zhou, Xuan; Khademhosseini, Ali; Zhang, Lijie Grace
2016-09-01
A biphasic artificial vascularized bone construct with regional bioactive factors is presented using dual 3D bioprinting platform technique, thereby forming a large functional bone grafts with organized vascular networks. Biocompatible mussel-inspired chemistry and "thiol-ene" click reaction are used to regionally immobilize bioactive factors during construct fabrication for modulating or improving cellular events. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Management of peri-implant infections
Directory of Open Access Journals (Sweden)
K L Vandana
2015-01-01
Full Text Available The ever-increasing popularity of dental implants in recent years has been associated with the reported incidence of short-term and long-term complications such as peri-implant mucositis and peri-implantitis. Therapies proposed for treating peri-implantitis are based on the evidence available for the treatment of periodontitis, and are aimed at reducing the bacterial load within peri-implant pockets and decontaminating implant surfaces, and, in some cases, attempting afterward to bring about bone regeneration. The treatment of peri-implant infections comprises conservative (nonsurgical and surgical approaches. This paper reviews various treatment strategies used for the treatment of peri-implant diseases. There are many approaches suggested by various authors for the treatment of peri-implant diseases, but there is no “ideal peri-implant therapy” that has been described in the literature. There is no consensus regarding the treatment protocol as the studies conducted so far have had varying study designs, small sample sizes, and short follow-up periods.
Rubino, Caroline
Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper
Biodegradable radioactive implants for glaucoma filtering surgery produced by ion implantation
Energy Technology Data Exchange (ETDEWEB)
Assmann, W. [Department fuer Physik, Ludwig-Maximilians-Universitaet Muenchen, 85748 Garching (Germany)]. E-mail: walter.assmann@lmu.de; Schubert, M. [Department fuer Physik, Ludwig-Maximilians-Universitaet Muenchen, 85748 Garching (Germany); Held, A. [Augenklinik, Technische Universitaet Muenchen, 81675 Munich (Germany); Pichler, A. [Augenklinik, Technische Universitaet Muenchen, 81675 Muenchen (Germany); Chill, A. [Zentralinstitut fuer Medizintechnik, Technische Universitaet Muenchen, 85748 Garching (Germany); Kiermaier, S. [Zentralinstitut fuer Medizintechnik, Technische Universitaet Muenchen, 85748 Garching (Germany); Schloesser, K. [Forschungszentrum Karlsruhe, 76021 Karlsruhe (Germany); Busch, H. [NTTF GmbH, 53619 Rheinbreitbach (Germany); Schenk, K. [NTTF GmbH, 53619 Rheinbreitbach (Germany); Streufert, D. [Acri.Tec GmbH, 16761 Hennigsdorf (Germany); Lanzl, I. [Augenklinik, Technische Universitaet Muenchen, 81675 Munich (Germany)
2007-04-15
A biodegradable, {beta}-emitting implant has been developed and successfully tested which prevents fresh intraocular pressure increase after glaucoma filtering surgery. Ion implantation has been used to load the polymeric implants with the {beta}-emitter {sup 32}P. The influence of ion implantation and gamma sterilisation on degradation and {sup 32}P-fixation behavior has been studied by ion beam and chemical analysis. Irradiation effects due to the applied ion fluence (10{sup 15} ions/cm{sup 2}) and gamma dose (25 kGy) are found to be tolerable.
Zeng, Fan-Gang
2004-01-01
More than 60,000 people worldwide use cochlear implants as a means to restore functional hearing. Although individual performance variability is still high, an average implant user can talk on the phone in a quiet environment. Cochlear-implant research has also matured as a field, as evidenced by the exponential growth in both the patient population and scientific publication. The present report examines current issues related to audiologic, clinical, engineering, anatomic, and physiologic aspects of cochlear implants, focusing on their psychophysical, speech, music, and cognitive performance. This report also forecasts clinical and research trends related to presurgical evaluation, fitting protocols, signal processing, and postsurgical rehabilitation in cochlear implants. Finally, a future landscape in amplification is presented that requires a unique, yet complementary, contribution from hearing aids, middle ear implants, and cochlear implants to achieve a total solution to the entire spectrum of hearing loss treatment and management.
Gökkus, Kemal; Sagtas, Ergin; Kesgin, Engin; Aydin, Ahmet Turan
2018-01-01
Intra-articular distal radius fractures have long been massively discussed in the literature, but regarding to fractures that possess rotated volar medial fragment in the joint a few amount papers has been written. In this article, we would like to emphasize the significance of the rotated palmar medial (lunate facet) fragment. A 39-year-old man fell from a height of about 3 m and landed on his right outstretched hand; within 40 min, he arrived at our clinic presenting with a severe pain and swelling in his right wrist. Initial X-rays of the wrist revealed dorsal subluxation of the radiocarpal joint with dorsal comminution of the radial articular surface and fracture of the radial styloid process, with (nearly inverted) ~ 140-150° rotation of the palmar medial fragment. With an additional volar approach, the fragment reduced and stabilized with two K-wires and wrist immobilized in external fixator. The patient returned to daily activities without any discomfort and pain after the 1 year from the surgery. Overlooking of palmar rotated osteochondral fragment will cause deficiency to build proper pre-operative strategy to approach the reduction of the fragment. The incompetence of reduction will deteriorate the articular surface and lead to early osteoarthritis of the wrist. The surgeon should detect this fragment and should be familiar with volar approaches of the wrist. Above average surgical experience would be needed for successful reduction.
Saltzman, Bryan M; Riboh, Jonathan C
2018-06-01
Articular cartilage injuries and early osteoarthritis are among the most common conditions seen by sports medicine physicians. Nonetheless, treatment options for articular degeneration are limited once the osteoarthritic cascade has started. Intense research is focused on the use of biologics, cartilage regeneration, and transplantation to help maintain and improve cartilage health. An underappreciated component of joint health is the subchondral bone. A comprehensive, nonsystematic review of the published literature was completed via a PubMed/MEDLINE search of the keywords "subchondral" AND "bone" from database inception through December 1, 2016. Clinical review. Level 4. Articles collected via the database search were assessed for the association of bone marrow lesions and osteoarthritis, cartilage regeneration, and ligamentous and meniscal injury; the clinical disorder known as painful bone marrow edema syndrome; and the subchondral bone as a target for medical and surgical intervention. A complex interplay exists between the articular cartilage of the knee and its underlying subchondral bone. The role of subchondral bone in the knee is intimately related to the outcomes from cartilage restoration procedures, ligamentous injury, meniscal pathology, and osteoarthritis. However, subchondral bone is often neglected when it should be viewed as a critical element of the osteochondral unit and a key player in joint health. Continued explorations into the intricacies of subchondral bone marrow abnormalities and implications for the advent of procedures such as subchondroplasty will inform further research efforts on how interventions aimed at the subchondral bone may provide durable options for knee joint preservation.
Micro-cutting of silicon implanted with hydrogen and post-implantation thermal treatment
Jelenković, Emil V.; To, Suet; Sundaravel, B.; Xiao, Gaobo; Huang, Hu
2016-07-01
It was reported that non-amorphizing implantation by hydrogen has a potential in improving silicon machining. Post-implantation high-temperature treatment will affect implantation-induced damage, which can have impact on silicon machining. In this article, a relation of a thermal annealing of hydrogen implanted in silicon to micro-cutting experiment is investigated. Hydrogen ions were implanted into 4″ silicon wafers with 175 keV, 150 keV, 125 keV and doses of 2 × 1016 cm-2, 2 × 1016 cm-2 and 3 × 1016 cm-2, respectively. In this way, low hydrogen atom-low defect concentration was created in the region less than ~0.8 μm deep and high hydrogen atom-high defect concentration was obtained at silicon depth of ~0.8-1.5 μm. The post-implantation annealing was carried out at 300 and 400 °C in nitrogen for 1 h. Physical and electrical properties of implanted and annealed samples were characterized by secondary ion mass spectroscopy (SIMS), X-ray diffraction (XRD), Rutherford backscattering (RBS) and nanoindentation. Plunge cutting experiment was carried out in and silicon crystal direction. The critical depth of cut and cutting force were monitored and found to be influenced by the annealing. The limits of hydrogen implantation annealing contribution to the cutting characteristics of silicon are discussed in light of implantation process and redistribution of hydrogen and defects generation during annealing process.
A biphasic oxidation of alcohols to aldehydes and ketones using a simplified packed-bed microreactor
Directory of Open Access Journals (Sweden)
Andrew Bogdan
2009-04-01
Full Text Available We demonstrate the preparation and characterization of a simplified packed-bed microreactor using an immobilized TEMPO catalyst shown to oxidize primary and secondary alcohols via the biphasic Anelli-Montanari protocol. Oxidations occurred in high yields with great stability over time. We observed that plugs of aqueous oxidant and organic alcohol entered the reactor as plugs but merged into an emulsion on the packed-bed. The emulsion coalesced into larger plugs upon exiting the reactor, leaving the organic product separate from the aqueous by-products. Furthermore, the microreactor oxidized a wide range of alcohols and remained active in excess of 100 trials without showing any loss of catalytic activity.
Directory of Open Access Journals (Sweden)
Mathilde Bayet-Robert
Full Text Available BACKGROUND: Curcumin (CUR has deserved extensive research due to its anti-inflammatory properties, of interest in human diseases including cancer. However, pleiotropic even paradoxical responses of tumor cells have been reported, and the mechanisms of action of CUR remain uncompletely elucidated. METHODOLOGY/PRINCIPAL FINDINGS: (1H-NMR spectroscopy-based metabolomics was applied to get novel insight into responses of MCF7 and MDA-MB-231 breast cancer cells to CUR alone, and MCF7 cells to CUR in cotreatment with docetaxel (DTX. In both cell types, a major target of CUR was glutathione metabolism. Total glutathione (GSx increased at low dose CUR (≤ 10 mg.l(-1-28 µM- (up to +121% in MCF7 cells, P<0.01, and +138% in MDA-MB-231 cells, P<0.01, but decreased at high dose (≥ 25 mg.l(-1 -70 µM- (-49%, in MCF7 cells, P<0.02, and -56% in MDA-MB-231 cells, P<0.025. At high dose, in both cell types, GSx-related metabolites decreased, including homocystein, creatine and taurine (-60 to -80%, all, P<0.05. Together with glutathione-S-transferase actvity, data established that GSx biosynthesis was upregulated at low dose, and GSx consumption activated at high dose. Another major target, in both cell types, was lipid metabolism involving, at high doses, accumulation of polyunsaturated and total free fatty acids (between ×4.5 and ×11, P<0.025, and decrease of glycerophospho-ethanolamine and -choline (about -60%, P<0.025. Multivariate statistical analyses showed a metabolic transition, even a biphasic behavior of some metabolites including GSx, between low and high doses. In addition, CUR at 10 mg.l(-1 in cotreatment with DTX induced modifications in glutathione metabolism, lipid metabolism, and glucose utilization. Some of these changes were biphasic depending on the duration of exposure to CUR. CONCLUSIONS/SIGNIFICANCE: Metabolomics reveals major metabolic targets of CUR in breast cancer cells, and biphasic responses that challenge the widely accepted
Biphasic influence of dexamethasone exposure on embryonic vertebrate skeleton development
International Nuclear Information System (INIS)
Cheng, Xin; Chen, Jian-long; Ma, Zheng-lai; Zhang, Zhao-long; Lv, Shun; Mai, Dong-mei; Liu, Jia-jia; Chuai, Manli; Lee, Kenneth Ka Ho; Wan, Chao; Yang, Xuesong
2014-01-01
in mesenchymal cell mass treated by low concentration of Dex. Mmp-13 expression was obviously up-regulated by Dex in both mesenchymal cells and primary chondrocyte cultures. And Col10a1 expression was also increased by Dex exposure in chondrocyte. In summary, we have revealed that different concentrations of Dex exposure during early gestation could exert a biphasic effect on vertebrate skeletal development. - Highlights: • Chick embryos occurred shortening of the long bone following Dex exposure. • Dex suppressed chondrocytes proliferation and promoted apoptosis. • Dex exposure decreased ALP production and up-regulated Runx-2 and Mmp-13. • Dex exhibited biphasic effects on chondrogenic proliferation and nodule formation. • The hypertrophy and ossification were accelerated by Dex both in vivo and in vitro
Biphasic influence of dexamethasone exposure on embryonic vertebrate skeleton development
Energy Technology Data Exchange (ETDEWEB)
Cheng, Xin; Chen, Jian-long; Ma, Zheng-lai; Zhang, Zhao-long; Lv, Shun; Mai, Dong-mei; Liu, Jia-jia [Department of Histology and Embryology, Key Laboratory for Regenerative Medicine of the Ministry of Education, School of Medicine, Jinan University, Guangzhou 510632 (China); Chuai, Manli [Division of Cell and Developmental Biology, University of Dundee, Dundee DD1 5EH (United Kingdom); Lee, Kenneth Ka Ho; Wan, Chao [Stem Cell and Regeneration Thematic Research Programme, School of Biomedical Sciences, Chinese University of Hong Kong, Shatin (Hong Kong); Yang, Xuesong, E-mail: yang_xuesong@126.com [Department of Histology and Embryology, Key Laboratory for Regenerative Medicine of the Ministry of Education, School of Medicine, Jinan University, Guangzhou 510632 (China); Institute of Fetal-Preterm Labor Medicine, Jinan University, Guangzhou 510632 (China)
2014-11-15
increased in mesenchymal cell mass treated by low concentration of Dex. Mmp-13 expression was obviously up-regulated by Dex in both mesenchymal cells and primary chondrocyte cultures. And Col10a1 expression was also increased by Dex exposure in chondrocyte. In summary, we have revealed that different concentrations of Dex exposure during early gestation could exert a biphasic effect on vertebrate skeletal development. - Highlights: • Chick embryos occurred shortening of the long bone following Dex exposure. • Dex suppressed chondrocytes proliferation and promoted apoptosis. • Dex exposure decreased ALP production and up-regulated Runx-2 and Mmp-13. • Dex exhibited biphasic effects on chondrogenic proliferation and nodule formation. • The hypertrophy and ossification were accelerated by Dex both in vivo and in vitro.
Yucesoy, Deniz T.; Hnilova, Marketa; Boone, Kyle; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan
2015-04-01
Implant-associated infections can have severe effects on the longevity of implant devices and they also represent a major cause of implant failures. Treating these infections associated with implants by antibiotics is not always an effective strategy due to poor penetration rates of antibiotics into biofilms. Additionally, emerging antibiotic resistance poses serious concerns. There is an urge to develop effective antibacterial surfaces that prevent bacterial adhesion and proliferation. A novel class of bacterial therapeutic agents, known as antimicrobial peptides (AMPs), are receiving increasing attention as an unconventional option to treat septic infection, partly due to their capacity to stimulate innate immune responses and for the difficulty of microorganisms to develop resistance towards them. While host and bacterial cells compete in determining the ultimate fate of the implant, functionalization of implant surfaces with AMPs can shift the balance and prevent implant infections. In the present study, we developed a novel chimeric peptide to functionalize the implant material surface. The chimeric peptide simultaneously presents two functionalities, with one domain binding to a titanium alloy implant surface through a titanium-binding domain while the other domain displays an antimicrobial property. This approach gains strength through control over the bio-material interfaces, a property built upon molecular recognition and self-assembly through a titanium alloy binding domain in the chimeric peptide. The efficiency of chimeric peptide both in-solution and absorbed onto titanium alloy surface was evaluated in vitro against three common human host infectious bacteria, Streptococcus mutans, Staphylococcus epidermidis, and Escherichia coli. In biological interactions such as occur on implants, it is the surface and the interface that dictate the ultimate outcome. Controlling the implant surface by creating an interface composed chimeric peptides may therefore
Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M; Mišić, Tijana
2015-05-01
This 1-year cohort study investigated stability and peri-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Each of 30 edentulous patients received 4 mini dental implants (1.8 mm × 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic(®) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The peri-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. The primary stability (Periotest value, PTV) measured -0.27 ± 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 ± 7.05) then increased significantly reaching (PTV = 6.17 ± 6.15) at 12 months. The mean PIBL measured -0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants. Copyright © 2014 Elsevier GmbH. All rights reserved.