WorldWideScience

Sample records for biphasic helical ct

  1. Helical CT for lumbosacral spinal

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuno, Satoshi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    1996-10-01

    The aim of this study was to investigate the efficacy of helical CT for lumbosacral pathology. We performed helical CT with multiplanar reconstruction, including the formation of oblique transaxial and coronal images, in 62 patients with various lumboscral disorders, including 32 non-enhanced CT and 36 CT after myelography. We correlated the appearance of the stenotic spinal canal and neoplastic disease with the findings on MRI obtained at nearly the same time. We obtained helical CT images in all cases in about 30 seconds. The diagnostic ability of helical CT was roughly equal to that of MRI in patients with spondylosis deformans, spondylolisthesis and herniated nucleus pulposus. There was no significant difference in diagnostic value for degenerative lumbosacral disease with canal and foraminal stenosis between non-enhanced and post-myelography helical CT. However, non-enhanced helical CT could not clearly demonstrate neoplastic disease because of the poor contrast resolution. Helical CT was useful in evaluating degenerative disorder and its diagnostic value was nearly equal to that of MRI. We considered that helical CT may be suitable for the assessment of patients with severe lumbago owing to the markedly shortened examination time. However, if helical CT is used as a screening method for lumbosacral disease, one must be careful of its limitations, for example, poor detectability of neoplastic disease, vascular anomalies and so on. (author)

  2. Intrahepatic arterioportal shunt: helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Quiroga, S.; Sebastia, M.C.; Moreiras, M.; Pallisa, E.; Rius, J.M.; Alvarez-Castells, A. [I. D. I. Hospital General i Universitari Vall d`Hebron, Barcelona (Spain). Servei de Radiodiagnostic

    1999-08-01

    The purpose of this study was to characterize the appearance of intrahepatic arterioportal shunts (APS) on two-phase helical CT, with emphasis on the importance of the hepatic arterial-dominant phase (HAP) to demonstrate perfusion disorders. We review eight cases of APS diagnosed by helical CT in our institution from January 1996 to March 1997 and describe the CT findings that established diagnosis. Five of them were confirmed by angiography. In seven (87.5 %) cases of APS we found early enhancement of the peripheral portal branches during the HAP of helical CT, whereas the superior mesenteric and splenic veins remained unenhanced. In five (62.5 %) cases of APS, transient, peripheral, triangular parenchymal enhancement was depicted during the HAP of helical CT; in four of these cases there was associated early enhancement of the portal branches. Helical CT can show perfusion alterations that might remain undiagnosed with conventional CT. An understanding of the hemodynamic changes that occur in APS can help in the interpretation of focal transient hepatic parenchymal enhancement and to differentiate APS from hypervascular tumors. We believe that the helical CT findings described herein are characteristic enough to suggest the diagnosis of APS. (orig.) With 3 figs., 1 tab., 16 refs.

  3. Helical CT in acute lower gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Olivier; Leroy, Christophe; Sergent, Geraldine [Department of Radiology, Hopital Huriez, 1 rue Polonovski, 59037 Lille (France); Bulois, Philippe; Saint-Drenant, Sophie; Paris, Jean-Claude [Department of Gastroenterology, Hopital Huriez, 1 rue Polonovski, 59037 Lille (France)

    2003-01-01

    The purpose of this study was to assess the usefulness of helical CT in depicting the location of acute lower gastrointestinal bleeding. A three-phase helical CT of the abdomen was performed in 24 patients referred for acute lower gastrointestinal bleeding. The diagnosis of the bleeding site was established by CT when there was at least one of the following criteria: spontaneous hyperdensity of the peribowel fat; contrast enhancement of the bowel wall; vascular extravasation of the contrast medium; thickening of the bowel wall; polyp or tumor; or vascular dilation. Diverticula alone were not enough to locate the bleeding site. The results of CT were compared with the diagnosis obtained by colonoscopy, enteroscopy, or surgery. A definite diagnosis was made in 19 patients. The bleeding site was located in the small bowel in 5 patients and the colon in 14 patients. The CT correctly located 4 small bowel hemorrhages and 11 colonic hemorrhages. Diagnosis of the primary lesion responsible for the bleeding was made in 10 patients. Our results suggest that helical CT could be a good diagnostic tool in acute lower gastrointestinal bleeding to help the physician to diagnose the bleeding site. (orig.)

  4. Virtual CT laparoscopic imaging using intravenous cholangiography with helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, Masafumi; Ishibashi, Masatoshi; Nishimura, Hiroshi; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine

    2000-08-01

    Laparoscopic cholecystectomy is a reatively new technology that allows for minimally invasive treatment of cholelithiasis. The purpose of this paper is to demonstrate the feasibility of virtual laparoscopic imaging using helical CT cholangiography with volume rendering technique. We used the technique with ten patients with suspected gallbladder abnormalities. Our imaging sets produced high quality 3D images with excellent visualization in 70% (7/10) of all cases. Virtual laparoscopic imaging was also compared with other imaging techniques and imaging using helical scans can proved useful in preoperative imaging. Furthermore, virtual laparoscopic imaging using helical scans can in surgical planning and serve as a visual aid in discussions between radiologists, surgeons, and patients. (author)

  5. Glomus tumor of the gastric body:helical CT findings

    Institute of Scientific and Technical Information of China (English)

    HU Xiao-yun; HU Chun-hong; FANG Xiang-ming; ZHANG Tong-hua

    2007-01-01

    @@ Glomus tumors, also known as glomangiomas, are rare and originate in the neuromyoarterial glomus, a normal arteriovenous shunt which is abundantly supplied with nerve fibers and fulfills a temperature-regulating function. The classic location of glomus tumor is the subungual region, but the tumor can occur elsewhere in the skin, soft tissues, nerves, stomach, nasal cavity, and trachea.1 In the gastrointestinal (GI) tract the tumor occurs more often in the stomach than other parts, and typically occurs as a solitary submucosal nodule in the antrum.2 We reported a case of glomus tumor originating from the greater curvature of stomach which was studied with contrast-enhanced helical computed tomography (CT) and described the characteristic helical CT findings of the rare lesion.

  6. Split renal function measured by triphasic helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Hackstein, Nils [Radiologische Gemeinschaftspraxis am Evangelischen Krankenhaus, Paul-Zipp-Str. 171, 35398 Giessen (Germany)]. E-mail: nils.hackstein@radiol.med.uni-giessen.de; Buch, Thomas [Department of Diagnostic Radiology, Klinikstr. 36, Justus-Liebig University Giessen, 35385 Giessen (Germany)]. E-mail: thomas.buch@radiol.med.uni-giessen.de; Rau, Wigbert S. [Department of Diagnostic Radiology, Klinikstr. 36, Justus-Liebig University Giessen, 35385 Giessen (Germany)]. E-mail: wigbert.rau@uniklinikum-giessen.de; Weimer, Rolf [Department of Internal Medicine, Klinikstr. 36, Justus-Liebig University Giessen, 35385 Giessen (Germany)]. E-mail: Rolf.Weimer@innere.med.uni-giessen.de; Klett, Rigobert [Clinic of Nuclear Medicine, Friedrichstr. 25, Justus-Liebig University Giessen, 35385 Giessen (Germany)]. E-mail: rigobert.klett@radiol.med.uni-giessen.de

    2007-02-15

    Purpose: To present a method for calculating split renal function solely from routine triphasic helical computed tomography (CT). Subjects and methods: We retrospectively included 26 adult patients who received renal scintigraphy and triphasic CT within 4 weeks in the years 2003 and 2004. All scans were performed using a standard abdominal protocol. Split renal function was calculated as relative single-kidney glomerular filtration rate (GFR) using a simplified 'two-point Patlak plot' technique. As a reference method, split renal function was determined from renal scintigraphy using the standard technique. Results: Linear correlation between the two methods was r = 0.91, split renal function (CT) = 0.0266 + 0.9573 x split renal function (scintigraphy). Conclusion: Split renal function can be measured accurately by minimally extended triphasic CT.

  7. Helical CT in the diagnosis of acute lower gastrointestinal haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Sabharwal, Rohan [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia); Vladica, Philip [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia)]. E-mail: rpvl@imag.wsahs.nsw.gov.au; Chou, Roger [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia); Law, W. Phillip [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia)

    2006-05-15

    Introduction: A pilot study to evaluate helical computer tomography (CT) as a diagnostic tool for acute lower gastrointestinal tract (GIT) bleeding. CT was compared to conventional angiography (CA) and colonoscopy for the diagnosis and detection of bleeding site in suspected cases of acute lower GIT bleeding. Methods: Seven patients presenting with acute lower GIT bleeding, between June and November 2002, underwent CT examinations. All of these seven patients underwent CA following CT. Emergency colonoscopies were performed on five patients investigated with both CT and CA. Median delay from the most recent episode of hematochezia to CT was two and a half hours, to CA was 3 h, and to colonoscopy was 4 h. None of the patients underwent nuclear medicine (NM) bleeding studies. Results: Haemoglobin drop in all patients was greater than 15 g/L in the first 24 h of presentation. The mean age was 68.86 years (range, 49-83 years). Comparing CT and CA, there were four concordant and three discordant results. Both modalities had concordant findings of two active bleeding sites, one non-bleeding rectal tumour, and one negative case result. In three patients, the source of bleeding was found on CT whereas CA was negative. Emergency colonoscopies performed in all of these three patients confirmed blood in the colon/ileum. Conclusion: Early experience suggests that CT is a safe, convenient and accurate diagnostic tool for acute lower GIT haemorrhage. It raises questions regarding the sensitivity of CA. A new management algorithm for acute lower GIT haemorrhage using CT as the pre-CA screening tool is being proposed based on the preliminary findings. Positive CT will allow directed therapeutic angiography, while negative CT will triage patients into alternative management pathways.

  8. Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2016-10-15

    We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)

  9. Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose.

    NARCIS (Netherlands)

    Rutten, A.; Meijs, M.F.; Vos, A.M.C.; Seidensticker, P.R.; Prokop, M.

    2010-01-01

    OBJECTIVE: To prospectively investigate the influence of contrast material concentration on enhancement in cardiac CT by using a biphasic single-injection protocol. METHODS: Sixty-four-row multidetector cardiac CT angiography was performed in 159 patients randomised to a moderate or high contrast me

  10. Recurrent pyogenic cholangitis : efficacy of two-phase helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ki Ho; Cho, June Sik; Shin, Kyung Sook; Lee, Se Hyo; Yu, Ho Jun; Park, Jin Yong; Kim, Young Min [College of Medicine, Chungnam National University, Taejon (Korea, Republic of)

    2000-01-01

    To evaluate the usefulness of two-phase helical CT in patients with recurrent pyogenic cholangitis (RPC) for the detection of acute inflammation and assessment of the degree of portal vein (PV) stenosis as a cause of hepatic parenchymal atrophy. We retrospectively reviewed two-phase CT findings in 30 patients with RPC diagnosed by CT, ERCP (endoscopic retrograde cholangiopancreatography), and surgery. Two-phase helical CT scans were obtained 30 sec (arterial phase, AP) and 70 sec (portal phase, PP) after the start of IV administration of contrast material. Without prior information, we analyzed periductal parenchymal and ductal wall enhancement during the AP and PP, and the degree of PV stenosis during the PP. Acute inflammation was diagnosed on the basis of symptoms and laboratory findings. To evaluate the relationship between parenchymal a trophy and PV stenosis, the degree of PV stenosis in affected parenchyma was classified as one of three types (mild, less than 25%; moderate, 25-75%; severe, greater than 75%), as compared with the diameter of normal PV in unaffected parenchyma. Ten of the 30 patients underwent CT during the acute inflammatory stage and 20 during the remission stage. Of the ten patients with acute inflammation, eight (80%) showed transient periductal parenchymal enhancement during the AP (p less than 0.05), which correlated closely with acute inflammation. Only three (15%) of the 20 patients with remission, however, showed transient parenchymal enhancement during this phase, at which time ductal wall enhancement was seen in three (30%) of the ten patients with acute inflammation and in seven (35%) of the 20 who showed remission (p greater than 0.05). There was no significant difference in parenchymal and ductal wall enhancement during the PP between patients with acute inflammation and those who showed remission (p greater than 0.05). Hepatic parenchymal atrophy of the lesion was seen in 24 patients. Among these, PV stenosis was mild in five

  11. Helical CT defecography; La defecografia con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M. [Genua Univ., Genua (Italy). Ist. di Radiologia, Cattedra R; Tornago, S. [Genua Univ. Genua (Italy). 2 Clinica Ortopedica

    1999-11-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases. [Italian] Scopo di questo lavoro e' ricercare un ruolo per la defeco-TC con apparecchiatura elicoidale nello studio delle malattie del pavimento pelvico confrontandola con i risultati consolidati della defecografia tradizionale. Si sono visionati 90 pazienti, 62 femmine e 28 maschi, con eta' compresa tra 24 e 82 anni, con defecografia tradizionale; di questi, 18 casi con diagnosi dubbia sono stati studiati anche con defeco-TC spirale

  12. Helical CT study of cerebral perfusion and related hemodynamic parameters

    Science.gov (United States)

    Cenic, Aleksa; Lee, Ting-Yim; Craen, Rosemary A.; Gelb, Adrian W.

    1997-05-01

    A convenient method for assessing cerebral perfusion and related functional parameters has been developed using a third generation slip-ring CT scanner. Dynamic contrast- enhanced scanning at the same level was employed to image the cerebral circulation at the rate of 1 image per second. Using data acquired with this non-helical mode of scanning, we have developed a method for the simultaneous in-vivo determination of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). These measurements are given in the same physiological units as positron emission tomography. In order to obtain accurate measurements of these parameters, methods were also developed to correct for recirculation and partial volume averaging in imaging small blood vessels. We have used 6 New Zealand white rabbits in our studies. For each rabbit, up to 3 CT measurements of CBF, CBV, and MTT were made at normocapnia under isoflurane anesthesia. Coronal sections through the brain were imaged while simultaneously imaging either a brain artery or the ear artery. Images were acquired for 1 minute as Isovue 300 was injected intravenously. In the acquired CT images, regions of interest in brain parenchyma and an artery were drawn. For each region of interest, the mean CT number in pre-contrast images was subtracted from the mean in post-contrast images to calculate the contrast concentration curves for the brain regions Q(t) and the arterial region Ca(t). Using a robust deconvolution method, the MTT was determined. CBV was then determined from the ratio of the areas of Q(t) and Ca(t). Finally, CBF was calculated from the Central Volume Principle. The mean regional CBF, CBV and MTT values were 73.3 +/- 5.1 ml/min/100g, 1.93 +/- 0.12 ml/100g and 1.80 +/- 0.18 s respectively. IN order to validate our CT CBF measurements, we also measured CBF using the well- established technique of microspheres with each CT study. The feasibility of our CT method to measure CBF accurately was

  13. Anti-aliasing weighting functions for multislice helical CT

    Science.gov (United States)

    La Riviere, Patrick J.; Pan, Xiaochuan

    2002-05-01

    We develop a new projection weighting function for interpolation and reconstruction of multi-slice helical computed tomography data with the hope of reducing longitudinal aliasing in reconstructed volumes. The weighting function is based on the application of the Papoulis generalized sampling theorem to the interlaced longitudinal samples acquired by the multi-slice scanner. We call the approach 180MAA, for multi-slice anti-aliasing. For pitch 3, the 180MAA approach yields high-quality images of the 3D Shepp-Logan phantom as well as a longitudinal MTF superior to that of the 180MLI approach, which is based on the use of linear interpolation. However, it is not as successful at mitigating aliasing as had been doped due to the presence of a significant and unexpected aliasing component that can be attributed to the small cone angle in multi-slice helical CT. The presence of this effect is interesting and significant in its own right, however.

  14. Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT

    Energy Technology Data Exchange (ETDEWEB)

    Sandstede, J.J.W.; Tschammler, A.; Beer, M.; Vogelsang, C.; Wittenberg, G.; Hahn, D. [Wuerzburg Univ. (Germany). Abt. fuer Roentgendiagnostik

    2001-08-01

    The aim of this study was to optimize bolus tracking for timing of the arterial phase of biphasic helical liver CT and to compare optimized bolus tracking to a standard delay. One hundred fifty patients were examined with six protocols: 5- or 10-s delay after triggering at a threshold of 50 or 75 or 100 HU enhancement in the aorta at the origin of the celiac arteries after injection of 120 ml contrast material at 3 ml/s. Optimal arterial enhancement was defined as 20-30% of hepatic enhancement in portal venous phase. Another 50 patients were examined with the optimized protocol and compared to 50 gender- and age-matched patients who underwent a 25-s standard delay. A 10-s delay after the 75-HU threshold resulted in the most patients with an optimal arterial phase (p<0.01). Thirty-one of 75 patients examined with this protocol showed optimal early liver enhancement. Bolus tracking compared with standard delay revealed only a trend for a difference (p=0.07). The outcome of automatic bolus tracking differs depending on the protocol used; however, optimal arterial phase imaging was seen in only 41% of patients, indicating only a trend for superior timing compared with a standard delay. (orig.)

  15. Evaluation of Helical CT Scanning in Judging the Invasion and Metastasis of Gastric Carcinoma

    Institute of Scientific and Technical Information of China (English)

    GAOJianbo; KONGXiangquan; GUOHua; LIShuxin; YANGXuehua; LIYintai; ZHANGZhixu

    2004-01-01

    To determine the accuracy of triphase enhanced helical CT in judging the invasion and metastasis of gastric carcinoma, and to discuss the relation between imaging signs and pathological findings. Methods: Triphase enhanced helical CT scanning was performed in 46 patients with gastric carcinoma. Imaging findings were compared with postoperative pathologic results. Results: (1) The accuracy of helical CT for diagnosing involvement of tunica serosa, lymph node metastasis and distant metastasis was 84.8%, 87.0% and 100~ respectively. (2) CT signs of serosal involvement, lymph node metastasis and distant metastasis were in good accordance with pathological findings (P<0.05). Conclusion: Triphase enhanced helical CT scans can comprehensively and precisely reflect the pathologic characteristics of gastric carcinoma, thus it is a reliable technique for the diagnosis of this disease.

  16. Helical CT in the primary trauma evaluation of the cervical spine: an evidence-based approach

    Energy Technology Data Exchange (ETDEWEB)

    Blackmore, C.C. [Washington Univ., Seattle, WA (United States). Dept. of Radiology; Center for Cost and Outcomes Research, Univ. of Washington, Seattle (United States); Dept. of Radiology, Harborview Medical Center, Seattle, WA (United States); Mann, F.A. [Washington Univ., Seattle, WA (United States). Dept. of Radiology; Harborview Injury Prevention and Research Center, University of Washington, Seattle (United States); Wilson, A.J. [Washington Univ., Seattle, WA (United States). Dept. of Radiology

    2000-11-01

    This review provides a summary of the cost-effectiveness, clinical utility, performance, and interpretation of screening helical cervical spine CT for trauma patients. Recent evidence supports the use of helical CT as a cost-effective method for screening the cervical spine in high-risk trauma patients. Screening cervical spine CT can be performed at the time of head CT to lower the cost of the evaluation, and when all short- and long-term costs are considered, CT may actually save money when compared with traditional radiographic screening. In addition to having higher sensitivity and specificity for cervical spine injury, CT screening also allows more rapid radiological clearance of the cervical spine than radiography. Patients who are involved in high-energy trauma, who sustain head injury, or who have neurological deficits are candidates for CT screening. Screening with CT may enhance detection of other potentially important injuries of the cervical region. (orig.)

  17. Myoepitheliomas of the Soft Palate: Helical CT Findings in Two Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Sook; Lee, Won Mi; Choi, Sun Myung [Eulji University School of Medicine, Seoul (Korea, Republic of)

    2007-12-15

    Myoepitheliomas are rare benign tumors that are composed entirely of myoepithelial cells. Myoepitheliomas account for less than 1% of all salivary gland tumors. Of all the salivary gland myoepitheliomas, 26% involve the minor salivary glands of the oral cavity, where the palate is the most common origin of intraoral myoepitheliomas. Since the establishment of a protocol for helical CT examinations of the neck, application of the protocol for head and neck tumors has been on the increase. As well as the detection of the tumor, helical CT assists in the characterization of the tumor with optimization of the efficiency of contrast material application. In this report, we describe the enhancement patterns of myoepitheliomas of the soft palate using helical CT scans. Analysis of the enhancement patterns of multiphasic CT images may help in the differential diagnosis of a slow growing well-demarcated mass of the soft palate. Multiphasic CT for a myoepithelioma shows various enhancement patterns characterized by the histological subtype.

  18. Helical mode lung 4D-CT reconstruction using Bayesian model.

    Science.gov (United States)

    He, Tiancheng; Xue, Zhong; Nitsch, Paige L; Teh, Bin S; Wong, Stephen T

    2013-01-01

    4D computed tomography (CT) has been widely used for treatment planning of thoracic and abdominal cancer radiotherapy. Current 4D-CT lung image reconstruction methods rely on respiratory gating to rearrange the large number of axial images into different phases, which may be subject to external surrogate errors due to poor reproducibility of breathing cycles. New image-matching-based reconstruction works better for the cine mode of 4D-CT acquisition than the helical mode because the table position of each axial image is different in helical mode and image matching might suffer from bigger errors. In helical mode, not only the phases but also the un-uniform table positions of images need to be considered. We propose a Bayesian method for automated 4D-CT lung image reconstruction in helical mode 4D scans. Each axial image is assigned to a respiratory phase based on the Bayesian framework that ensures spatial and temporal smoothness of surfaces of anatomical structures. Iterative optimization is used to reconstruct a series of 3D-CT images for subjects undergoing 4D scans. In experiments, we compared visually and quantitatively the results of the proposed Bayesian 4D-CT reconstruction algorithm with the respiratory surrogate and the image matching-based method. The results showed that the proposed algorithm yielded better 4D-CT for helical scans.

  19. Severity assessment of acute pulmonary embolism: evaluation using helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Collomb, D.; Paramelle, P.J.; Calaque, O. [Department of Radiology, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Bosson, J.L. [Department of Statistics and Vascular diseases, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Vanzetto, G. [Department of Cardiology, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Barnoud, D. [Department of Medical Intensive Care, CHU Grenoble, BP 218, BP 218, 38043, Grenoble Cedex (France); Pison, C. [Department of Pulmonary Medicine, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Coulomb, M.; Ferretti, G.

    2003-07-01

    The objective was to evaluate the helical CT (HCT) criteria that could indicate severe pulmonary embolism (PE). In a retrospective study, 81 patients (mean age 62 years) with clinical suspicion of PE explored by HCT were studied. The patients were separated into three different groups according to clinical severity and treatment decisions: group SPE included patients with severe PE based on clinical data who were treated by fibrinolysis or embolectomy (n=20); group NSPE included patients with non-severe PE who received heparin (n=30); and group WPE included patients without PE (n=31). For each patient we calculated a vascular obstruction index based on the site of obstruction and the degree of occlusion in the pulmonary artery. We noted the HCT signs, i.e., cardiac and pulmonary artery dimensions, that could indicate acute cor pulmonale. According to multivariate analysis, factors significantly correlated with the severity of PE were: the vascular obstruction index (group SPE: 54%; group NSPE: 24%; p<0.001); the maximum minor axis of the left ventricle (group SPE: 30.2 mm; group NSPE: 40.4 mm; p<0.001); the diameter of the central pulmonary artery (group SPE: 32.4 mm; group NSPE: 28.3 mm; p<0.001); the maximum minor axis of the right ventricle (group SPE: 47.5 mm; group NSPE: 42.7 mm; p=0.029); the right ventricle/left ventricle minor axis ratio (group SPE: 1.63; group NSPE: 1.09; p<0.0001). Our data suggest that hemodynamic severity of PE can be assessed on HCT scans by measuring four main criteria: the vascular obstruction index; the minimum diameter of the left ventricle; the RV:LV ratio; and the diameter of the central pulmonary artery. (orig.)

  20. USING OF MULTISLICE HELICAL CT COLONOGRAPHY IN PATIENTS WITH MALIGNANT LESIONS OF COLON

    Institute of Scientific and Technical Information of China (English)

    Ming-wei Qin; Wei-dong Pan; Guan-ning Cong; Yun Wang; Yun-qing Zhang; Wen-bin Mou; Zheng-yu Jin

    2005-01-01

    Objective To investigate the techniques and clinical applications of multislice helical computed tomography (CT) colono graphy in colonic lesions. Methods Fifty-nine patients with malignant lesions of colon underwent volume scanning using multislice helical CT. Four types of reconstruction including CT virtual colonoscopy (CTVC), shaded surface display (SSD), Raysum, and mu ltiple planar reconstruction (MPR) were used for image post-processing. The results were compared with those of colonos copy and pathology. Results Multislice helical CT colonography detected 54 colorectal carcinomas, 4 adenomas with focal carcinoma, 1 non-Hodgkin's lymphoma (NHL). The lesions' number, size, location, morphology, stricture of intestinal cavity, infiltration, and metastasis were shown satisfactorily by multislice helical CT colonography. Whole colon could be shown in all patients. CT colonography displayed 4 synchronous colonic tumors, 1 ascending colon carcinoma combined with left renal carcinoma among 54 patients with colonic carcinomas. The accuracy of location of CT colonography was 100%. There were 9 cases that CT showed the tumor location was different from the finding of conventional colonoscopy, while all of the CT location were proven exact by operation. CT colonography also displayed the infiltration of serous layer and fatty tissue in 45 cases; 21 cases matched the pathological results in all the 24 cases of suspicious lymph node metastasis, the sensitivity was 87.5%, the specificity was 90.6%; 9 cases hepatic metastasis, 2 ovarian metastasis, and 1 double adrenal gland metastasis.Conclusions Multislice helical CT colonography is effective in preoperative diagnosis, location, stage, and making treatment plan of colorectal carcinoma. It can display the portion not seen during colonoscopy and may have an adjunctive role.

  1. Biphasic {sup 68}Ga-PSMA-HBED-CC-PET/CT in patients with recurrent and high-risk prostate carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Sahlmann, Carsten-Oliver; Meller, Birgit; Bouter, Caroline; Meller, Johannes [University Medical Center Goettingen, Department of Nuclear Medicine, Goettingen (Germany); Ritter, Christian Oliver; Lotz, Joachim [University Medical Center Goettingen, Department of Diagnostic and Interventional Radiology, Goettingen (Germany); Stroebel, Philipp [University Medical Center Goettingen, Department of Pathology, Goettingen (Germany); Trojan, Lutz; Hijazi, Sameh [University Medical Center Goettingen, Department of Urology, Goettingen (Germany)

    2016-05-15

    Binding of {sup 68}Ga-PSMA-HBED-CC ({sup 68}Ga-PSMA) at prostate cancer (PC) cells increases over time. A biphasic protocol may help separating benign from tumor lesions. The aim of this study was the retrospective evaluation of a diagnostic incremental value of a dual-time point (biphasic) {sup 68}Ga-PSMA-PET/CT in patients with prostate cancer. Retrospective analysis of 35 consecutive patients (49-78 years, median 71) with newly diagnosed PC (12/35) or recurrence of PC (23/35). PET/CT (Gemini TF16, Philips) was acquired 1 h and 3 h p. i. of 140-392 MBq (300 MBq median) {sup 68}Ga-PSMA, followed by a diagnostic contrast CT. PET findings were correlated with histology or unequivocal CT findings. Semiquantitative PET data (SUVmax, SUV mean) were acquired and target-to-background-ratios (T/B-ratio) were calculated for benign and malign lesions for both time points. Size of lymph nodes (LN) on diagnostic CT was recorded. Statistical analysis was performed for assessment of significant changes of semiquantitative PET-parameters over time and for correlation of size and uptake of lymph nodes. One hundred and four lesions were evaluated. Sixty lesions were referenced by histology or unequivocal CT findings, including eight (13.3 %) histopathologically benign lymph nodes, 12 (20 %) histopathologically lymph node metastases, 12 (20 %) primary tumors, three (5 %) local recurrences, and 25 (41.7 %) bone metastases. Forty-four lesions were axillary LN with normal CT-appearance. Benign lesions had significantly lower SUVmax and T/B-ratios compared with malignant findings. Malign lesions showed a significant increase of both parameters over time compared to benign findings. There was no correlation between LN size and SUVmax. The sensitivity, specificity, the positive predictive value and negative predictive value of PET/CT regarding pelvic LN was 94 %, 99 %, 89 %, and 99.5 %, respectively. In contrast to benign tissues, the uptake of proven tumor lesions increases on {sup 68

  2. Cervical spine evaluation in urban trauma centers: lowering institutional costs and complications through helical CT scan.

    Science.gov (United States)

    Grogan, Eric L; Morris, John A; Dittus, Robert S; Moore, Derek E; Poulose, Benjamin K; Diaz, Jose J; Speroff, Theodore

    2005-02-01

    In the evaluation of the cervical spine (c-spine), helical CT scan has higher sensitivity and specificity than plain radiographs in the moderate- and high-risk trauma population, but is more costly. We hypothesize that institutional costs associated with missed injuries make helical CT scan the least costly approach. A cost-minimization study was performed using decision analysis examining helical CT scan versus radiographic evaluation of the c-spine. Parameter estimates were obtained from the literature for probability of c-spine injury, probability of paralysis after missed injury, plain film sensitivity and specificity, CT scan sensitivity and specificity, and settlement cost of missed injuries resulting in paralysis. Institutional costs of CT scan and plain radiography were used. Sensitivity analyses tested robustness of strategy preference, accounted for parameter variability, and determined threshold values for individual parameters on strategy preference. C-spine evaluation with helical CT scan has an expected cost of US 554 dollars per patient compared with US 2,142 dollars for plain films. CT scan is the least costly alternative if threshold values exceed US 58,180 dollars for institutional settlement costs, 0.9% for probability of c-spine fracture, and 1.7% for probability of paralysis. Plain films are least costly if CT scan costs surpass US 1,918 dollars or plain film sensitivity exceeds 90%. Helical CT scan is the preferred initial screening test for detection of cervical spine fractures among moderate- to high-risk patients seen in urban trauma centers, reducing the incidence of paralysis resulting from false-negative imaging studies and institutional costs, when settlement costs are taken into account.

  3. Pancreatic adenocarcinoma: dual-phase helical CT with surgical and histopathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Park, Seong Hoon; Yun, Ki Jung; Won, Jong Jin [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2003-03-01

    To determine the accuracy of dual-phase helical CT in assessing the resectability of pancreatic ductal adenocarcinoma, and to correlate the CT findings with the surgical and histopathologic findings. Thirty patients with pathologically proven cancer of the pancreas underwent arterial-and portal-phase helical CT scanning, and in the two of these, single-level dynamic CT was performed during celiac and superior mesenteric arteriography. In 17 patients who underwent surgery for potentially resectable cancer of the pancreatic head, tumor resectability was assessed. The CT findings were analyzed and correlated with these of surgery and histopathology. In 13 (76%) of the 17 patients who underwent surgery, tumors were resectable. Their average size was 2.76 cm (arterial phase), 2.30 cm (portal phase), and 2.48 cm (pathologically determined) and the overall accuracy of helical CT for assessing resectability was 87%. In all patients, the central portion of the tumors exhibited hypoattenuation at both phases; the peripheral portion showed hypoattenuation at the arterial phase and iso- (n=10) or hyperattenuation (n=3) at the portal phase. Single-level dynamic CT depicted a persistently hypoattenuating central portion and progressive and prolonged enhancement of the periphery. CT-histopathologic correlation showed that central hypoattenuation indicated the presence of tumor cells, necrosis (n=3) and mucin (n=4), while the peripheral iso- or hyperattenuated areas seen at the portal phase represented fibrosis and inflammatory infiltration. Histopathologic examination revealed tumoral infiltration of peripancreatic fat tissue (n=11) and microvascular invasion of major peripancreatic vessels (n=7). The dual-phase helical CT is useful in the determination of resectability in pancreas cancer and CT findings represent well the histopathologic features of pancreas cancer.

  4. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    The purpose of this study was (1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and (2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20.

  5. Bile duct complications of hepatic arterial infusion chemotherapy evaluated by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Phongkitkarun, S. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)]. E-mail: rasih@mahidol.ac.th; Kobayashi, S. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Varavithya, V. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Huang, X. [Department of Biostatistics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Curley, S.A. [Department of Surgical Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Charnsangavej, C. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2005-06-01

    AIM: To describe the imaging findings of bile duct complications of hepatic arterial infusion chemotherapy (HAIC) using helical CT, to set diagnostic criteria, to develop a CT grading system, and to correlate these with clinical findings and laboratory data. METHODS: Follow-up helical CT of the abdomen was performed every 3 months for 60 patients receiving HAIC. Three radiologists reviewed all CT studies before and after treatment, using either the picture archiving and communication system or hard copies. The findings of bile duct abnormalities were correlated with findings from other imaging techniques, clinical symptoms and laboratory data. RESULTS: Bile duct abnormalities developed in 34 (57%) of cases either during HAIC or 1 to 12 months after treatment. In 14 (41%) of these 34 patients, enhancement of the hepatic parenchyma along the dilated bile duct or in the segmental or lobar distribution was observed. In 43 cases (72%), normal or abnormal alkaline phosphatase levels were consistent with normal or abnormal CT findings, respectively. Increasing alkaline phosphatase and bilirubin levels were related to CT grade. CONCLUSION: Imaging findings of bile duct complications of HAIC are similar to those of primary sclerosing cholangitis, and correlate well with abnormal clinical and laboratory data. In the presence of such clinical abnormalities, thin-section helical CT with careful review of the imaging studies helps to determine the correct diagnosis, monitor the changes and guide appropriate treatment.

  6. [Prognostic significance of helical CT in patients with destructive pancreatitis].

    Science.gov (United States)

    Bulanova, T V

    2000-01-01

    Spiral scanning computed tomography (CT) is able not only to image the pancreas and to evaluate its structure, but to interpret the status of the adjacent organs and tissues. CT symptoms of pancreatic necrotic changes and multiorgan failure were studied in the prospective follow-up of 47 patients with prior destructive pancreatitis (158 studies). CT differentially substantiated indications for choosing treatment policy for different forms of pancreatic lesions. The paper gives a quantitative assessment of necrotic pancreatic parencymatous areas and shows its prognostic value.

  7. An experimental study for qualitatively diagnosing stapes lesions by helical 3-dimensional CT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaue, Akifumi; Kuki, Kiyonori; Yamanaka, Noboru [Wakayama Medical Univ., Wakayama (Japan); Nishimura, Michihiko

    2001-08-01

    To evaluate qualitative diagnosis of stapes lesions by 3-dimensional computed tomography (3D-CT) combined with superselective image processing (3D-SS) of stapes, we studied helical 3D-CT on a phantom model of the temporal bone. Two stapes models were used-1 made from the bone filler, Celatite, consistent in bone density but changing in cross sectional area, and the other made from an apacerum rod used in quantitative computed tomography (QCT), consistent in cross sectional area but changing in bone density. These stapes models were put into a skull phantom and analyzed by helical 3D-CT. The influence of the tympanic cavity conditions on CT images of stapes was evaluated by filling the phantom model with Vaseline following 3D selective reconstruction. In all stapes models, lowering the lower CT window width threshold resulted in an enlarged cross-sectional area of the model. The higher the bone density, the lower the increase in cross-sectional area in the image. The stapes model with lower density had greater influence on the imaging by tympanic cavity conditions and was likely to be misdiagnosed as showing higher bone density. Based on the experimental study, 3D-SS by helical 3D-CT appears to be a useful measure for qualitatively diagnosing stapes lesions. (author)

  8. Epidurography: Comparison with CT-, helical-CT- and MR-Epidurography; Die Epidurographie: Vergleich mit CT-, Spiral-CT- und MR-Epidurographie

    Energy Technology Data Exchange (ETDEWEB)

    Tomczak, R. [Univ. Ulm, Klinik fuer Radiologie (Germany); Seeling, W. [Univ. Ulm, Klinik fuer Anaesthesiologie (Germany); Rieber, A. [Univ. Ulm, Klinik fuer Radiologie (Germany); Sokiranski, R. [Univ. Ulm, Klinik fuer Radiologie (Germany); Rilinger, N. [Univ. Ulm, Klinik fuer Radiologie (Germany); Brambs, H.J. [Univ. Ulm, Klinik fuer Radiologie (Germany)

    1996-08-01

    Purpose: The purpose of this study was to explain the origin of image patterns demonstrated by conventional epidurography, which is a controversially discussed topic in recent literature. Material and methods: After introduction of thoracic epidural catheters and iopamidol injection, conventional epidurography and CT-epidurography were performed on 25 preoperative patients. After injection of Gadolinium-DTPA MR-epidurography was performed in two patients treated for chronic pain with already introduced epidural catheters. Three volunteers also underwent identical imaging after introduction of thoracic epidural catheters and in addition helical-CT epidurography using twin-beam technology. Results: 40% of the patients demonstrated the railroad track phenomenon. We were able to prove that it is a sign of a rhythmically variable filling of segments of the lateral epidural space with contrast medium. 76% of the patients demonstrated no ventral epidural space at the thoracic level. 56% of the patients showed a medial area of translucence combined with a band-shaped contrasting of the epidural space in the standard ap view. This was proven in all cases to be a plica mediana dorsalis by CT. In all volunteers who underwent helical-CT and MR epidurography we observed the railroad track phenomenon and the filling defect of the anterior thoracic epidural space. Conclusion: CT epidurography is well suited for obtaining new insights into the interpretation of findings obtained by conventional epidurography. (orig.) [Deutsch] Zielsetzung: Das Ziel der vorliegenden Untersuchung war es, Kontrastmitteldarstellungen der konventionellen Epidurographie, die in der Literatur widerspruechlich diskutiert werden, durch CT- und MR-Epidurographie zu erklaeren. Material und Methoden: Nach der Injektion von jodhaltigem Kontrastmittel ueber einen epiduralen Katheter wurden bei 25 praeoperativen Patienten eine Epidurographie und eine CT-Epidurographie durchgefuehrt. Zwei Schmerzpatienten mit

  9. Non-contrast thin-section helical CT of urinary tract calculi in children

    Energy Technology Data Exchange (ETDEWEB)

    Strouse, Peter J. [Section of Pediatric Radiology, University of Michigan Medical Center, Ann Arbor, MI (United States); Bates, Gregory D. [Department of Radiology, Columbus Children' s Hospital, Columbus, OH (United States); Bloom, David A. [Department of Pediatric Imaging, Children' s Hospital of Michigan, Detroit, MI (United States); Goodsitt, Mitchell M. [Department of Radiology, University of Michigan Medical Center, Ann Arbor, MI (United States)

    2002-05-01

    Background: Non-contrast thin-section helical CT has gained acceptance for the diagnosis of urinary tract calculi in adults, but experience with the technique in children is limited. Purpose: To evaluate the utility of non-contrast thin section helical CT for the diagnosis of urinary tract calculi in children. Materials and methods: Radiology databases at three pediatric institutions were searched to identify all pediatric patients evaluated by ''renal stone'' protocol CT scans (no oral or intravenous contrast, scans covering the entire urinary tract obtained in helical mode with narrow collimation (< 5 mm)). CT scans were reviewed for the primary finding of urinary tract calculi, for secondary signs of acute urinary tract obstruction and for evidence of alternative diagnoses. Medical records were reviewed to determine clinical presentation and to confirm the eventual diagnosis. Results: One hundred thirty-seven scans of 113 children (mean age: 11.2 years) were studied. Thirty-eight of 94 examinations (40%) performed on 82 children for acute pain and/or hematuria showed ureteral calculi. Alternative diagnoses were suggested by CT on 16 scans (17%). Twenty-eight scans were performed on 10 asymptomatic children with known calculus disease confirming renal stone burden on 21 scans (75%) and persistent ureteral calculi on 6 scans (21%). Upper tract calculi were demonstrated on 10 of 15 scans (67%) performed to evaluate for calculi in patients with known non-calculus genitourinary tract abnormalities. Conclusions: Non-contrast thin section helical CT is a useful method to diagnose urinary tract calculi in children. Radiation dose in this retrospective study may exceed the lowest possible radiation dose for diagnostic accuracy. Further research is needed to optimize CT imaging parameters, while maintaining diagnostic accuracy and minimizing radiation dose. (orig.)

  10. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  11. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT.

    Science.gov (United States)

    Jaeckle, T; Stuber, G; Hoffmann, M H K; Jeltsch, M; Schmitz, B L; Aschoff, A J

    2008-07-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT.

  12. Three-dimensional CT imaging with a helical scan on temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Sakakura, Atsushi; Yoshikawa, Shuji; Shimizu, Takaya; Sueyoshi, Kozo; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1996-06-01

    To evaluate the usefulness of three-dimensional (3D) CT on the lesions of temporal bone, we studied 19 patients with disorders on the region of temporal bone by high speed helical CT. The results showed that 8 patients with congenital hearing disorder had deficiency of the auditory ossicles, 2 patients with chronic otitis media had deformity and shortness of the auditory ossicles, 4 patients with trauma had fracture of the temporal bone (1 patient was complicated by doubtful fracture of the incus), 5 patients (4 patients with acquired hearing disorder and 1 patient with otorrhea) had space-occupying lesions. 3-D helical CT could detect abnormal findings on all the patients and it was an important examination for the temporal bone. (author)

  13. Investigation of structural resorption behavior of biphasic bioceramics with help of gravimetry, μCT, SEM, and XRD.

    Science.gov (United States)

    de Wild, Michael; Amacher, Fabienne; Bradbury, Christopher R; Molenberg, Aart

    2016-04-01

    Resorbable bone substitute materials are widely used for bone augmentation after tumor resection, parallel to implant placement, or in critical size bone defects. In this study, the structural dissolution of a biphasic calcium phosphate bone substitute material with a hydroxyapatite (HA)/tricalcium phosphate (β-TCP) ratio of 60/40 was investigated by repeatedly placing porous blocks in EDTA solution at 37 °C. At several time points, the blocks were investigated by SEM, µCT, and gravimetry. It was found that always complete 2-3 µm sized grains were removed from the structure and that the β-TCP is dissolved more rapidly. This selective dissolution of the β-TCP grains was confirmed by XRD measurements. The blocks were eroded from the outside toward the center. The structure remained mechanically stable because the central part showed a delayed degradation and because the slower dissolving HA grains preserved the integrity of the structure.

  14. The usefulness of three-dimensional helical CT for the detection of abnormalities of the auditory ossicles

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Shimizu, Tadafumi; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1996-04-01

    To evaluate the usefulness of three-dimensional (3D) helical CT for the detection of abnormalities of the auditory ossicles, 3D helical CT of the middle ear was performed in seven patients with hearing disorder. It revealed that 4 patients had congenital deficiency of the auditory ossicles, 2 patients with chronic otitis media had shortening of the incus and one patient with head injury had doubtful fracture of the incus. This study indicated that 3D helical CT of the middle ear can represent the auditory ossicles objectively and can offer detailed diagnosis. (author).

  15. Evaluation of contrast-enhanced helical hydro-CT in staging gastric cancer

    Institute of Scientific and Technical Information of China (English)

    Wen-Zhou Wei; Jie-Ping Yu; Jun Li; Chang-Sheng Liu; Xiao-Hua Zheng

    2005-01-01

    AIM: To discuss the helical computed tomography (CT) characteristics of gastric cancer and evaluate the diagnostic value of contrast-enhanced helical hydro-CT (HHCT) in staging gastric cancer.METHODS: A total of 50 patients with gastric cancer were included in this study. The CT findings in them were retrospectively analyzed and correlated with pathologic findings at surgery. All patients were preoperatively imaged by plain and contrast-enhanced helical CT after orally ingesting 1 000-1 500 mL water. Peristalsis was minimized by intra-venous administration of spasmolytics.RESULTS: The foci of gastric cancer became more prominent in all the 50 patients and showed strong enhancement in contrast-enhanced HHCT. The tumor was located at the gastric cardia in 14 cases, at the gastric fundus in 3 cases, at the gastric body in 8 cases, at the gastric antrum in 4 cases, at the gastric fundus and the body in 8 cases, at the gastric body and antrum in 11 cases, and at three segments of the stomach in 2 cases.The CT features of gastric cancer were focal or diffuse mural thickening, soft tissue mass, cancerous ulcer, stenosis of stomach, infiltration to adjacent tissues, lymph node and distant metastases. Strong contrast enhancement of the gastric wall was closely related to gastric cancer. The accuracy rate of contrast-enhanced HHCT in staging gastric cancer was 86% (43/50). The detection rate of lymph node metastases by CT was 60% (12/20).CONCLUSION: Contrast-enhanced HHCT is a reliable method to diagnose and stage gastric cancer.

  16. The role of dual-phase helical CT in assessing resectability of carcinoma of the gallbladder

    Energy Technology Data Exchange (ETDEWEB)

    Kumaran, Vinay; Pande, Girish Kumar; Sahni, Peush; Chattopadhyay, Tushar Kanti [Department of Gastrointestinal Surgery, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110 029 (India); Gulati, Manpreet Singh; Paul, Shashi Bala [Department of Radiodiagnosis, All India Institute of Medical Sciences, Ansari Nagar, New Delhi 110 029 (India)

    2002-08-01

    Our objective was to assess the ability of dual-phase helical CT (DHCT) to predict resectability of carcinoma of gallbladder (CaGB). Thirty-two consecutive patients suspected of having CaGB on clinical examination and sonography presented to our centre over 10-month period. All these 32 patients underwent DHCT. Fifteen patients were considered inoperable and 2 had xanthogranulomatous cholecystitis. The remaining 15 patients (10 women, 5 men; age range 33-72 years) underwent surgery and had histopathological confirmation of CaGB and were included in the study based on the following criteria: presence of mass in gallbladder fossa on sonography and DHCT, and confirmation at surgery and histopathological examination. Axial reconstructions of 2 mm were obtained (collimation 3 mm, table speed 4.5 mm/s) for arterial (scan delay 20 s) and venous (scan delay 60 s) phases on a helical scanner. The criteria used for unresectability were: distant metastasis (liver, peritoneum, lymph nodes), extensive local contiguous organ spread, involvement of secondary biliary confluence of both lobes of liver, tumoral invasion of main portal vein, or proper hepatic artery or simultaneous invasion of one side hepatic artery and the other side portal vein. The CT findings related to unresectability were correlated with surgical findings. On the basis of CT findings, 10 patients were unresectable and 5 were resectable. Of the 10 patients considered unresectable, 9 had tumours that were unresectable at surgery (sensitivity 100%, positive predictive value 90%). Five patients had more than one reason and 4 had one reason alone for being unresectable (lymph nodes, n=2; hepatic metastasis, n=1; and vascular invasion, n=1). All 5 patients considered resectable based on CT findings had resectable tumours at surgery (negative predictive value 100%). The overall accuracy of CT was 93.3%. Dual-phase helical CT comprehensively evaluates CaGB and may be a useful tool in preoperative staging of this

  17. Three-dimensional helical CT imaging of bone and joint diseases in the trunk and the hip joints. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Gong Hohghan [Jangxi Medical Coll. (China). First Affiliated Hospital; Hiraishi, Kumiko; Doi, Miwako; Matsui, Ritsuo; Simizu, Tadafumi; Sueyoshi, Kouzou; Narabayashi, Isamu

    1997-12-01

    To confirm the utility of CT scan images for orthopedic surgeons managing patients with complex disorders, we have produced and studied three-dimensional images from helical CT scans of 28 patients with various bone and joint disorders in the trunk and the hip joint. The CT scanner employed was a Toshiba X-force, and the 3D-CT images were constructed on an X-link50. The 3D images obtained could be observed from various projections. Congenital vertebral malformations, spondylosis, OPLL, osteonecrosis, fractures, and bone tumors were examined, and the 3D helical CT images brought useful information to bear on the spatial location and extent of the lesions. Therefore, 3D helical CT should become an indispensable tool for both preoperative examination and post-operative follow-up studies in orthopedic surgery. (author)

  18. Emergencies in the retroperitoneum: assessment of spread of disease by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, M. E-mail: michelescialpi@libero.it; Scaglione, M.; Angelelli, G.; Lupattelli, L.; Resta, M.C.; Resta, M.; Rotondo, A

    2004-04-01

    Acute pancreatitis, leaking abdominal aortic aneurysm, and renal trauma frequently occur in the setting of patients with abdominal nontraumatic and traumatic injury; it represents the most urgent conditions that may determine the presence of fluid collections or haematoma in the retroperitoneum. Single spiral CT and multidetector-row CT (MDCT) play an important role in diagnosis of retroperitoneal emergencies, providing useful informations on the type, site, extent and management of the fluid collections. An accurate CT assessment requires the awareness of the existence of dissectable retroperitoneal fascial planes. Fluid collections or haematoma tends to escape the retroperitoneal site of origin into planes extend from the diaphragm to the pelvic floor. We assess the multicompartimental anatomy of the retroperitoneum and the pathway of spread of the most frequent retroperitoneal fluid collections or haematoma by helical CT.

  19. The helical three-dimensional CT in the diagnosis of torticollis with occipitocondylar hypoplasia

    Energy Technology Data Exchange (ETDEWEB)

    Ilkko, E.; Tikkakoski, T.; Pyhtinen, J. [Department of Radiology, Oulu University Hospital, Kajaanintie 50, 90220 Oulu (Finland)

    1998-11-01

    Congenital anomalies of the atlanto-occipital and atlantoaxial joints are rare. Those most commonly reported are atlantoaxial instability, basilar impression, anomalies of the odontoid process, laxity of the transverse atlantal ligament and atlanto-occipital fusion. Occipital condylar hypoplasia is infrequent and difficult to recognise. We recently diagnosed it using helical 3D CT in association with torticollis in two patients. The first patient had a several year history of torticollis. The second patient had acute cervical lymphadenitis associated with post-operative torticollis. 3D CT distinctly revealed atlantoaxial subluxation with hypoplasia of the occipital condyles in both cases. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  20. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  1. Small hepatocellular carcinoma with peripheral enhancement:pathological correlation with dual phase images by helical CT

    Institute of Scientific and Technical Information of China (English)

    ZHENG Ke-guo; SHEN Jing-xian; WANG Gen-shu; XU Da-sheng

    2007-01-01

    Background The peripheral enhancement of small hepatocellular carcinoma (SHCC) is a rare appearance in dual phase images by helical computed tomography (CT). This study discusses this phenomenon and its correlative histopathology.Methods The helical CT dual phase appearance of peripheral enhancement in SHCC was analyzed in 21 cases (22 lesions). All lesions were confirmed as SHCC by histopathological examination.Results In these 22 lesions, enhanced peripheral ring in 20 lesions was incomplete, the thickness of enhanced peripheral ring varied and mural node could be found in hepatic arterial phase; only 2 lesions had complete peripheral ring enhancement and ring of uniform thickness in hepatic arterial phase. The enhancement of some peripheral rings and mural nodes dropped to very low density in portal venous phase. The tumour cells were grade Ⅰ in 3 lesions, Ⅱ in 16, Ⅲ in 2 and Ⅳ in 1. The vascular supply was more abundant at the border than in the centre of 15 lesions and the vascular supply was deficient in both centre and border of the remaining 7 lesions. In 3 lesions, the pseudocapsule showed in the border of the lesion. In 12 lesions, flecks of necrosis were found in the border and/or centre of the lesion.Conclusions The characteristic peripheral enhancement in helical CT dual phase images of small hepatocellular carcinoma correlates with different vascular supplies, fibrous capsule and necrosis of the lesion.

  2. Peripancreatic vascular abnormalities complicating acute pancreatitis: contrast-enhanced helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Mortele, Koenraad J. E-mail: kmortele@partners.org; Mergo, Patricia J.; Taylor, Helena M.; Wiesner, Walter; Cantisani, Vito; Ernst, Michael D.; Kalantari, Babak N.; Ros, Pablo R

    2004-10-01

    Objective: To determine the prevalence and morphologic helical computed tomography (CT) features of peripancreatic vascular abnormalities in patients with acute pancreatic inflammatory disease in correlation with the severity of the pancreatitis. Materials and methods: One hundred and fifty-nine contrast-enhanced helical CT scans of 100 consecutive patients with acute pancreatitis were retrospectively and independently reviewed by three observers. CT scans were scored using the CT severity index (CTSI): pancreatitis was graded as mild (0-2 points), moderate (3-6 points), and severe (7-10 points). Interobserver agreement for both the CT severity index and the presence of peripancreatic vascular abnormalities was calculated (K-statistic). Correlation between the prevalence of complications and the degree of pancreatitis was estimated using Fisher's exact test. Results: The severity of pancreatitis was graded as mild (n=59 scans), moderate (n=82 scans), and severe (n=18 scans). Venous abnormalities detected included splenic vein (SV) thrombosis (31 scans, 19 patients), superior mesenteric vein (SMV) thrombosis (20 scans, 14 patients), and portal vein (PV) thrombosis (17 scans, 13 patients). Arterial hemorrhage occurred in five patients (6 scans). In our series, no cases of arterial pseudoaneurysm formation were detected. The interobserver agreement range for scoring the degree of pancreatitis and the overall presence of major vascular abnormalities was 75.5-79.2 and 86.2-98.8%, respectively. The presence of the vascular abnormalities in correlation with the severity of pancreatitis was variable. Conclusion: Vascular abnormalities are relatively common CT findings in association with acute pancreatitis. The CT severity index is insufficiently accurate in predicting some of these complications since no statistically significant correlation between their prevalence and the severity of pancreatitis could be established.

  3. Determination of optimal parameters for three-dimensional reconstruction images of central airways using helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Hirose, Takahumi; Akata, Soichi; Matsuno, Naoto; Nagao, Takeshi; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    2002-01-01

    Three-dimensional (3D) image reconstruction of central airways using helical CT requires several user-defined parameters that exceed the requirements of conventional CT. The purpose of this study was to evaluate the optimal parameters for 3D images of central airways using helical CT. In our experimental study using a piglet immediately after sacrifice, 3D images of the central airway were evaluated with changes of 3D imaging parameters, such as detector collimation (1, 2, 3 and 6 mm), table speed (1, 2, 3 and 5 mm/sec), tube electric current (50, 100, 150, 200 and 250 mA), reconstruction interval (0.3, 0.5, 1, 2 and 3 mm), algorithm (mediastinum and lung) and interpolation method (180 deg and 360 deg). To minimize detector collimation, table speed, and reconstruction interval could provide the best 3D images of the central airway. Stair-step artifacts could also be reduced with a slow table speed. However, decreasing the collimation and table speed decreases not only the effective section thickness but also the scan coverage that can be achieved with a helical CT. For routine diagnosis, we conclude that optimal parameters for 3D images of the central airway are to minimize the table speed necessary to cover the volume of interest and to set detector collimation to 1/2 of the table speed. The reconstruction intervals should also be selected at up to 1/2 of the detector collimation, but with trade-offs of increased image processing time, data storage requirements, and physician time for image review. Regarding to tube electric current, 200 mA or more was necessary. Pixel noise increased with the algorithm for the lung. The 180 deg interpolation is better than 360 deg interpolation due to thin effective section thickness. (author)

  4. Implementation and evaluation of two helical CT reconstruction algorithms in CIVA

    Science.gov (United States)

    Banjak, H.; Costin, M.; Vienne, C.; Kaftandjian, V.

    2016-02-01

    The large majority of industrial CT systems reconstruct the 3D volume by using an acquisition on a circular trajec-tory. However, when inspecting long objects which are highly anisotropic, this scanning geometry creates severe artifacts in the reconstruction. For this reason, the use of an advanced CT scanning method like helical data acquisition is an efficient way to address this aspect known as the long-object problem. Recently, several analytically exact and quasi-exact inversion formulas for helical cone-beam reconstruction have been proposed. Among them, we identified two algorithms of interest for our case. These algorithms are exact and of filtered back-projection structure. In this work we implemented the filtered-backprojection (FBP) and backprojection-filtration (BPF) algorithms of Zou and Pan (2004). For performance evaluation, we present a numerical compari-son of the two selected algorithms with the helical FDK algorithm using both complete (noiseless and noisy) and truncated data generated by CIVA (the simulation platform for non-destructive testing techniques developed at CEA).

  5. Esophageal varices before and after endoscopic variceal ligation: evaluation using helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, T.; Namba, R.; Matsuoka, T.; Tabuchi, K.; Yamamoto, K.; Uesugi, Y.; Matsui, R.; Sueyoshi, K.; Narabayashi, I. [Dept. of Radiology, Osaka Medical College (Japan)

    1999-10-01

    The purpose of this study was to demonstrate the utility of helical CT in assessing the therapeutic effects of endoscopic variceal ligation (EVL). Twenty-four patients with esophageal varices were examined. Helical scanning was initiated 60 s after intravenous injection (Iopamidol 300 mgI/ml, total 120 ml, 3 ml/s) was started. Esophageal varices were clearly depicted as high-density areas. Multiplanar reformation and 3D images demonstrated collateral circulation three-dimensionally. After EVL, mucosal high-density areas had diminished markedly, but collateral veins around the esophagus, and gastro- and/or spleno-renal shunts, were unchanged in all patients. Of 21 patients with collateral circulation, esophageal varices recurred endoscopically in 6 patients within 12 months. In 3 patients without collateral circulation, esophageal varices did not recur within 12 months. From these findings, we conclude that helical CT is a useful method for assessing the therapeutic effects of EVL. (orig.) With 3 figs., 1 tab., 14 refs.

  6. Parametric response mapping of contrast-enhanced biphasic CT for evaluating tumour viability of hepatocellular carcinoma after TACE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B.; Shin, Hoen-Oh; Kaercher, Daniel; Hasdemir, Davut; Kaireit, Till; Lutat, Carolin; Meyer, Bernhard C.; Wacker, Frank K.; Rodt, Thomas [Hannover Medical School, Department of Diagnostic and Interventional Radiology, Hannover (Germany); Murray, Tim [Beaumont Hospital, Department of Diagnostic and Interventional Radiology, Dublin (Ireland); Vogel, Arndt [Hannover Medical School, Gastroenterology, Hepatology and Endocrinology, Hannover (Germany)

    2016-10-15

    To determine the feasibility and role of parametric response mapping (PRM) for quantitative assessment of regional contrast-enhancement patterns in hepatocellular carcinoma (HCC). Biphasic CT of 19 patients receiving repetitive conventional transarterial chemoembolisation (cTACE) for intermediate stage HCC were retrospectively analysed at baseline and follow-up at 3, 6, and 9 months. Voxel-based registration of arterial and porto-venous phases, with segmentation of the largest target lesion was performed. Frequency distribution plots of density-pairs of segmented voxels were generated. To differentiate necrotic, hypervascular and non-hypervascular tumour, and lipiodol/calcification, thresholds of 30, 100, and 300 HU were applied. Changes in density frequency plots over time were analysed and compared to response and assessment criteria (WHO, RECIST, EASL, mRECIST) and survival. PRM was feasible in all cases. Tumour volumes and hypervascular/non-hypervascular volume ratio showed significant longitudinal decrease (p < 0.05). Hypervascular volume at baseline was inversely correlated to survival (R = -0.57, p = 0.005). The only predictive parameter following cTACE to show significant survival difference was the change of the viable/non-viable ratio (p = 0.044), whereas common response assessment criteria showed no significant difference in survival. PRM allows a quantitative and more precise assessment of regional tumour vascularisation patterns and may be helpful for TACE treatment planning and response assessment. (orig.)

  7. 3D iterative helical targeted CT. Application to contrast-enhanced vascular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gendron, David; Goussard, Yves; Hamelin, Benoit [Ecole Polytechnique de Montreal, Montreal, QC (Canada). Inst. de Genie Biomedical; Dussault, Jean-Pierre [Sherbrooke Univ., Sherbrooke, QC (Canada). Dept. d' Informatique; Beaudoin, Gilles; Cloutier, Guy; Chartrand-Lefebvre, Carl; Hadjadj, Sofiane; Soulez, Gilles [Montreal Univ., Hopital Notre-Dame, Montreal, QC (Canada). Centre de Recherche du Centre Hospitalier

    2011-07-01

    We present the implementation of a iterative reconstruction algorithm for 3D helical computed tomography. The main difficulties of helical CT reconstruction are the large memory footprint of the tools and data involved, as well as the very long runtime of the iterative methods. The proposed solution hinges on the following three features: (1) a multiple-ray-driven projection operator with a parsimonious representation; (2) a targeted reconstruction framework that restricts the iterative reconstruction effort to a region of interest within the imaged volume; (3) the choice of a fast convergent solver for the nonlinear reconstruction problem. Results on clinical-size data show significant improvement in image quality over the default scanner reconstruction and an acceptable computation cost. (orig.)

  8. Helical CT angiography of renal arteries: two-years of experience; Angioscanographie helicoidale des arteres renales

    Energy Technology Data Exchange (ETDEWEB)

    Beregi, J.P.; Louvegny, S.; Ceugnart, L.; Willoteaux, S.; Elkohen, M.; Desmoucelle, F.; Deklunder, G.; Wattinne, L. [Centre Hospitalier Universitaire, 59 - Lille (France)

    1997-08-01

    To evaluate the role of helical CT angiography (CTA) in the detection of renal artery stenosis in hypertensive patients. We studied 300 hypertensive patients (50 prospectively and 250 consecutively) with CTA and arteriography (n = 118). Helical acquisition (collimation 3 mm; pitch = 1, 20 seconds acquisition time) was performed 20-45 seconds after contrast injection (300 mgl/ml; 120 ml, 4 ml/sec). Transverse axial views and 3D reconstructions were analysed (360 deg interpolation algorithm, 1 mm overlapped). In the prospective series, CTA sensibility was 100 % for main renal artery stenoses and specificity was 98.2 %; however 7/32 renal accessory arteries were not visualized. In the 300 patients studies, seventy-four stenoses were detected. There were 5 false-positive and 5 false-negative studies. Secondary hypertension was detected in 26 % of patients (including 14 cases of adrenal hyperplasia). CTA is a promising technique for the detection of renal artery stenosis in hypertensive patients. (authors).

  9. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-10-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  10. Combined magnetic resonance urography and targeted helical CT in patients with renal colic: a new approach to reduce delivered dose.

    Science.gov (United States)

    Blandino, Alfredo; Minutoli, Fabio; Scribano, Emanuele; Vinci, Sergio; Magno, Carlo; Pergolizzi, Stefano; Settineri, Nicola; Pandolfo, Ignazio; Gaeta, Michele

    2004-08-01

    To determine whether magnetic resonance urography (MRU), obtained before helical computed tomography (CT) in patients with acute renal colic, can help delimit the obstructed area to be subsequently examined by a targeted CT scan, thus reducing the dose of radiation. Patients (51) with symptoms of acute renal colic underwent MRU and a total urinary tract helical CT. CT images from the 5 cm below the level of ureteral obstruction as demonstrated by MRU were selected out. Combined interpretation of MRU and selected CT images constituted protocol A. Protocol B consisted of the entire unenhanced helical CT of the urinary tract. The two protocols were compared regarding the following points: 1) sensitivity in diagnosing the presence of obstructing urinary stones, and 2) the delivered radiation dose. Protocol A and protocol B had, respectively, 98% and 100% sensitivity in demonstrating ureteral stone as a cause of renal colic. Estimated average dose calculated from phantom study was 0.52 mSv for protocol A and 2.83 mSv for protocol B. Therefore, the effective radiation dose was 5.4 times lower in protocol A compared to protocol B. Combined MRU and short helical CT has a high sensitivity in detecting ureteral calculi with a reduced radiation dose. Copyright 2004 Wiley-Liss, Inc.

  11. Spiral (helical) CT of tracheo-bronchial diseases; La tomodensitometrie spiralee (helicoidale) en pathologie tracheobronchique

    Energy Technology Data Exchange (ETDEWEB)

    Remy, J.; Remy-Jardin, M.; Bonnel, F.; Masson, P. [Hopital Calmette, Service de Radiologie, 59 - Lille (France)

    2000-03-01

    The acquisition techniques, including some important dosimetric considerations, and the reconstruction methods reviewing the tomographic, broncho-graphic and endoscopic techniques are first taken into consideration. They are applied to the most usual problems and diseases encountered in the daily activity: pitfalls of interpretation of the tracheobronchial tree; management of hemoptysis; preoperative of proximal bronchial carcinoma; aids and complements to diagnostic and interventional bronchoscopy. The main purpose of this review, which merges the modern technology of spiral (helical) CT with the multislice acquisition in the very near future, consists in delivering, whenever possible, an integrated diagnostic and therapeutic approach of imaging, endoscopy and surgery. (authors)

  12. Pitfalls in detection of acute gastrointestinal bleeding with multi-detector row helical CT.

    Science.gov (United States)

    Stuber, T; Hoffmann, M H K; Stuber, G; Klass, O; Feuerlein, S; Aschoff, A J

    2009-07-01

    Contrast-enhanced multi-detector row helical CT angiography is establishing itself as an accurate, rapid, and non-invasive diagnostic modality in patients with acute gastrointestinal bleeding. On arterial phase MDCT images ongoing hemorrhage can be revealed as an area of active extravasation of contrast material within the bowel lumen. This pictorial essay gives a short overview of current diagnostic modalities in assessing acute GI tract bleeding, typical MDCT findings, and depicts potential pitfalls in the detection of acute GI bleeding with MDCT.

  13. Evaluation of foramen magnum in gender determination using helical CT scanning

    Science.gov (United States)

    Uthman, AT; Al-Rawi, NH; Al-Timimi, JF

    2012-01-01

    Objective The present research was undertaken to study the accuracy and reliability of the foramen magnum (FM) and some cranial measurements in gender classification through the use of reconstructed helical CT images. Methods 88 patients (43 males and 45 females; age range, 20–49 years) were selected for this study. FM sagittal diameter, transverse diameter, area and circumference were measured and data were subjected to discriminant analysis for gender using multiple regression analysis. Results FM circumference and area were the best discriminant parameters that could be used to study sexual dimorphism with an overall accuracy of 67% and 69.3%, respectively. By using multivariate analysis, 90.7% of FM dimensions of males and 73.3% of FM dimensions of females were sexed correctly. Conclusion It can be concluded that the reconstructed CT image can provide valuable measurements for the FM and could be used for sexing when other methods are inconclusive. PMID:22116135

  14. Transient heterogeneous enhancement on dual-phase helical CT of liver

    Energy Technology Data Exchange (ETDEWEB)

    Ishibashi, Tadashi; Hama, Hikaru; Oikawa, Hideki; Yamada, Takayuki; Abe, Hiroyuki; Saitoh, Haruo; Sakamoto, Kiyohiko [Tohoku Univ., Sendai (Japan). School of Medicine; Satoh, Akihiro

    1996-08-01

    Transient heterogeneous enhancement was seen on the arterial phase of dual-phase helical CT of the liver. The shape of the enhancement was appeared wedged or patchy. These phenomena without liver tumor were observed in 23 (2.3%) of 1012 patients with suspected hepatobiliary disease. Plain CT showed no attenuation difference in the liver. Twenty-two of these 23 cases were diagnosed as scarred liver, A-P shunt caused by liver biopsy, acute cholecystitis, liver abscess, liver cirrhosis, or advanced pancreas head cancer. The diagnosis of one case was uncertain. These phenomena were thought to be caused by a regional direct increase in hepatic arterial flow due to arterial-portal (A-P) shunt, or hypervascular tumor; or a compensatory increase in hepatic arterial flow as a result of decreased portal venous flow caused by tumor invasion or severe liver cirrhosis. (author)

  15. Usefulness of helical CT angiography for diagnosis of anomalous origin of coronary artery. Comparison with coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Shinozaki, Hitoshi; Kondo, Takeshi; Ishikawa, Emiko [Fujita Health Univ., Toyoake, Aichi (Japan)] [and others

    1998-07-01

    Usefulness of helical CT angiography with reconstruction image of diastolic phase synchronized with electrocardiogram was compared with that of coronary angiography for diagnosis of anomalous origin of coronary artery. Patients were 2 males and 3 females, and average age was 66.4 year. Three cardiologists judged images and did not confirmed the origin and direction of coronary artery in 60% of cases. Helical CT was carried out with heartbeat <60/min by oral administration of propranolol (10-20 mg) one hour before the test. Half image was reconstructed by using data of diastolic phase which is 600 msec back from R-wave of an electrocardiogram. Multiplanar reconstruction (MPR) image and 3D image were provided. Two radiologists judged these images. A judgment was completed with 4 cases among 5 cases, and two judgments agreed well. For diagnosis of anomalous origin of coronary artery, helical CT had good accuracy and was more sensitive than coronary angiography. (K.H.)

  16. Computer-aided diagnosis workstation and database system for chest diagnosis based on multi-helical CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Mori, Kiyoshi; Eguchi, Kenji; Kaneko, Masahiro; Kakinuma, Ryutarou; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru; Sasagawa, Michizou

    2006-03-01

    Multi-helical CT scanner advanced remarkably at the speed at which the chest CT images were acquired for mass screening. Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images and a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification. We also have developed electronic medical recording system and prototype internet system for the community health in two or more regions by using the Virtual Private Network router and Biometric fingerprint authentication system and Biometric face authentication system for safety of medical information. Based on these diagnostic assistance methods, we have now developed a new computer-aided workstation and database that can display suspected lesions three-dimensionally in a short time. This paper describes basic studies that have been conducted to evaluate this new system. The results of this study indicate that our computer-aided diagnosis workstation and network system can increase diagnostic speed, diagnostic accuracy and safety of medical information.

  17. Diagnostic accuracy of segmental enhancement inversion for the diagnosis of renal oncocytoma using biphasic computed tomography (CT) and multiphase contrast-enhanced magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Schieda, Nicola; McInnes, Matthew D.F. [The University of Ottawa, The Ottawa Hospital, Department of Medical Imaging, Ottawa, Ontario (Canada); Al-Subhi, Maali; Flood, Trevor A.; El-Khodary, Mohammed [The University of Ottawa, The Ottawa Hospital, Department of Anatomical Pathology, Ottawa, ON (Canada)

    2014-11-15

    Segmental enhancement inversion (SEI) is a controversial imaging finding reportedly specific for the diagnosis of renal oncocytoma. The purpose of this study was to re-evaluate SEI using biphasic CT and multiphase MRI. With research ethics board approval, a retrospective analysis of patients with resection or biopsy of oncocytoma or chromophobe renal cell carcinoma (Ch-RCC) between 2008-2012 was performed. Twenty-four patients with oncocytoma and 13 patients with Ch-RCC underwent CT, while 13 patients with oncocytoma and 10 patients with Ch-RCC underwent MRI. Two blinded radiologists reviewed the CT and MRI studies independently in separate sessions to assess for SEI. A third radiologist established consensus. Interobserver variability was calculated and diagnostic accuracy was compared using ROC and the Fisher exact test. There was no difference in detection of SEI between oncocytoma and Ch-RCC at CT [both readers (p = 0.65, 0.5) and consensus review (p = 0.29)] or MRI [both readers (p = 0.64, 0.74) and consensus review (p = 0.53)]. The interobserver variability at CT (K = 0.28-0.33) and MRI (K = 0.25-0.44) was fair. The sensitivity and specificity for diagnosis of oncocytoma were 21 % and 92 % at CT and 15 % and 90 % at MRI. SEI is not useful for the diagnosis of renal oncocytoma with CT or MRI. (orig.)

  18. Helical CT findings of gastric wall thickening by peptic ulcer : compared with gastric adenocarcinoma with ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Jung; Choi, Jong Chul; Seo, Keum Soo; Koo, Bon Sik; Park, Byeong Ho; Kim, Chung Ku; Lee, Ki Nam; Nam, Kyung Jin [College of Medicine, Dong A University, Pusan (Korea, Republic of)

    2000-02-01

    To compare on the basis of helical CT findings gastric wall thickening of peptic gastric ulcer with that of gastric adenocarcinoma with ulcer. Thirty-eight patients with pathologically proven gastric lesion (17 cases of peptic ulcer and 21 cases of ulcerative or ulceroinfiltrative gastric cancer (Borrman type II, III)) underwent helical CT, and the findings were retrospectively reviewed in terms of maximum abnormal wall thickness, preservation of the inner enhancing layer, the presence three discriminate layers of gastric wall, and enhancement pattern. The enhancement pattern of abnormally thick wall was compared with that of the portal phase of back muscle, and was defined as low, iso, or high. The Chi-square test and Student t test were used for statistical analysis. In cases of peptic ulcer and gastric cancer with ulceration, maximum abnormal wall thickness was 7-30 (mean, 16.1)mm, and 11-33 (mean, 21.8)mm, respectively. The inner enhancing layer was preserved in 15 of 17 patients (88.2%) and one of 21 (4.8%); three discriminate layers of gastric wall were observed in 8 of 17 patients (47.0%), and one of 21 (4.8%). The enhancement pattern was low in 12 of 17 patients (70.5%), and 3 of 21 (14.3%); iso in 4 of 17 (23.5%), and 4 of 21 (19.0%), and high in one of 17 (5.9%), and 14 of 21 (66.7%). All figures refer, respectively, to the two distinct conditions. In terms of preservation of the inner enhancing layer, three discriminate layers of gastric wall, and a low enhancement pattern, there were statistically significant differences between peptic ulcer and gastric adenocarcinoma with ulcer. Where the enhancement was high, however, the statistically significant difference between the two conditions was even greater. There was no statistically significant difference in terms of gastric wall thickness or iso-attenuation of thickened gastric. Helical CT findings of gastric wall thickening, preservation of the inner enhancing layer, and three discriminate layers of

  19. Limited-angle reverse helical cone-beam CT for pipeline with low rank decomposition

    Science.gov (United States)

    Wu, Dong; Zeng, Li

    2014-10-01

    In this paper, tomographic imaging of pipeline in service by cone-beam computed tomography (CBCT) is studied. With the developed scanning strategy and image model, the quality of reconstructed image is improved. First, a limited-angle reverse helical scanning strategy based on C-arm computed tomography (C-arm CT) is developed for the projection data acquisition of pipeline in service. Then, an image model which considering the resemblance among slices of pipeline is developed. Finally, split Bregman method based algorithm is implemented in solving the model aforementioned. Preliminary results of simulation experiments show that the projection data acquisition strategy and reconstruction method are efficient and feasible, and our method is superior to Feldkamp-Davis-Kress (FDK) algorithm and simultaneous algebraic reconstruction technique (SART).

  20. Helical CT cholangiography and MR cholangiography in postoperative patients with congenital choledochal cyst

    Energy Technology Data Exchange (ETDEWEB)

    Koshinaga, Tugumichi; Ikeda, Taro; Hagiwara, Noritsugu; Nonaka, Michiaki; Fukuzawa, Masahiro [Nihon Univ., Tokyo (Japan). School of Medicine

    2000-01-01

    Cholangitis and intrahepatic cholelithiasis have been reported as hepatic complications long after total cyst excision in patients with congenital choledochal cyst. The aim of this study was to identify the hepatic ductal features and compare the findings obtained by Helical CT cholangiography (HCTC) with those by MR-cholangiography (MRC). Hepatic ductal configurations of 12 patients who had undergone total excision of the extrahepatic bile duct were examined by HCTC and MRC. HCTC and MRC are useful for identifying hepatic ductal dilatation, although HCTC is better described for the anastomotic site of hepaticojejunostomy and hepatic ductal stenosis, in the postoperative follow-up of patients. Early detection of hepatic ductal configurations is of great importance in the long-term follow-up. (author)

  1. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  2. Role of Early Arterial Phase Multislice Helical CT Angiography in Evaluation of Hepatocellular Carcinoma

    Institute of Scientific and Technical Information of China (English)

    TANGBinghang; HEYaqi; LILiangcai; HUANGDecheng; WURenguo; YUYuanlong

    2005-01-01

    Objective: To investigate the clinical application of early arterial phase multislice CT angiography (MSCTA) of hepatic vessels in evaluation of middle or advanced stage hepatocellular carcinoma.Methods: Trigger Bolus program was used to carry out MSCTA in early and late arterial phases and portal vein phase with single breath holding. Hepatic vessels were reconstructed from the original images of early arterial phase by post processing. The blood supply of tumor and normal liver tissue and the appearances of venous thrombosis and arteriovenous shunts were analyzed. Results: The MSCTA with early arterial phase could perfectly display the origin, shape and amount of feeding vessels to normal liver tissue and tumor in middle or advanced stage hepatocellular carcinoma. It had the ability of displaying the arteriovenous shunts better than that in conventional dual phased liver scanning. Conclusion: MSCTA of hepatic vessels with early arterial phase acquisition using multislice helical CT in middle or advance stage hepatocellular carcinoma has favorable and promising application. It can be used as an imaging method for comprehensive assessment of the hepatocellular carcinoma before treatment.

  3. Usefulness of helical CT in the diagnosis of strangulation in small bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hye; Kim, Won Hong; Jeon, Yong Sun; Shin, Dong Jae; Cho, Soon Gu; Lee, Chang Keun; Choi, Sun Keun [College of Medicine, Inha Univ., Incheon (Korea, Republic of)

    2004-12-01

    We wished to evaluate the usefulness of helical CT for the diagnosis of strangulation of the dilated small bowels. The CT scans of 31 patients with small bowel obstruction from various causes were reviewed retrospectively. Thirteen of these patients were confirmed as small bowel strangulation by surgery and pathology. Fourteen patients underwent surgery, but they had no strangulation. Three patients were reduced by using a nasogastric tube and one infant with intussusception was reduced by air reduction. The following CT findings of strangulation were evaluated: reduced bowel wall enhancement by visual assessment and measuring the HU, ascites, thickening of bowel wall, abnormal mesenteric vessel location and whirlpool appearance, and mesenteric venous engorgement. For the precise evaluation of reduced bowel wall enhancement, the HUs were measured by 1 mm{sup 2} of ROI, and the differences of HUs between the well enhanced bowel and poorly enhanced bowel were compared. For the diagnosis of strangulation, measurement of HU of the bowel wall could improve the sensitivity from 69% to 100%. The specificity of both methods, by visual assessment and measurement of HU, was 94%. Ascites had a sensitivity of 69% and specificity of 44%. Thickening of bowel wall had a sensitivity of 38% and specificity of 78%. Abnormal mesenteric vessel location and whirlpool appearance had a sensitivity of 38% and specificity of 83%. Mesenteric venous engorgement had a sensitivity of 31% and specificity of 72%. Measurement of HU of the bowe wall after contrast enhancement can be a useful method in the differential diagnosis between the strangulated and non-strangulated bowels in patients with small bowel obstruction.

  4. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  5. Dynamic evaluation of pelvic floor reconstructive surgery using radiopaque meshes and three-dimensional helical CT

    Directory of Open Access Journals (Sweden)

    Paulo Palma

    2010-04-01

    Full Text Available PURPOSE: This prospective study was performed to achieve visualization of the reestablishment of anatomy after reconstructive surgery in the different pelvic compartments with non-absorbable radiopaque meshes, providing valuable anatomic information for surgeons implanting meshes. MATERIALS AND METHODS: A total of 30 female patients with stress urinary incontinence (SUI, anterior and posterior vaginal wall prolapse, or both underwent surgical repair using radiopaque meshes after written informed consent. Patients with SUI underwent five different surgeries. Patients with anterior vaginal prolapse underwent a procedure using a combined pre-pubic and transobturator mesh, and those with posterior vaginal prolapse underwent posterior slingplasty. Three-dimensional reconstruction using helical CT was performed four weeks postoperatively. RESULTS: In all cases, the mesh was clearly visualized. Transobturator slings were shown at the midurethra, and the anchoring tails perforated the obturator foramen at the safety region. Mini-slings were in the proper place, and computed angiography revealed that the anchoring system was away from the obturator vessels. In patients undergoing procedure for anterior vaginal prolapse, both pre-pubic armpit and obturator slings were clearly seen and the mesh was in the proper position, supporting the bladder base and occluding the distal part of the urogenital hiatus. Transcoccygeal sacropexy revealed indirectly a well-supported "neo rectovaginal fascia" and the anchoring tails at the level of ischial spines. CONCLUSION: Three-dimensional helical tomography images of the female pelvis using radiopaque meshes have a potential role in improving our understanding of pelvic floor reconstructive surgeries. These radiopaque meshes might be the basis of a new investigative methodology.

  6. Imaging skeletal anatomy of injured cervical spine specimens: comparison of single-slice vs multi-slice helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Alamo, L.; Herold, T.; Funke, M.; Kopka, L.; Grabbe, E. [Department of Radiology, Georg August-University Goettingen, Robert-Koch-Strasse 40, 37075 Goettingen (Germany)

    2002-08-01

    Our objective was to compare a single-slice CT (SS-CT) scanner with a multi-slice CT (MS-CT) scanner in the depiction of osseous anatomic structures and fractures of the upper cervical spine. Two cervical spine specimens with artificial trauma were scanned with a SS-CT scanner (HighSpeed, CT/i, GE, Milwaukee, Wis.) by using various collimations (1, 3, 5 mm) and pitch factors (1, 1.5, 2, 3) and a four-slice helical CT scanner (LightSpeed, QX/i, GE, Milwaukee, Wis.) by using various table speeds ranging from 3.75 to 15 mm/rotation for a pitch of 0.75 and from 7.5 to 30 mm/rotation for a pitch of 1.5. Images were reconstructed with an interval of 1 mm. Sagittal and coronal multiplanar reconstructions of the primary and reconstructed data set were performed. For MS-CT a tube current resulting in equivalent image noise as with SS-CT was used. All images were judged by two observers using a 4-point scale. The best image quality for SS-CT was achieved with the smallest slice thickness (1 mm) and a pitch smaller than 2 resulting in a table speed of up to 2 mm per gantry rotation (4 points). A reduction of the slice thickness rather than of the table speed proved to be beneficial at MS-CT. Therefore, the optimal scan protocol in MS-CT included a slice thickness of 1.25 mm with a table speed of 7.5 mm/360 using a pitch of 1.5 (4 points), resulting in a faster scan time than when a pitch of 0.75 (4 points) was used. This study indicates that MS-CT could provide equivalent image quality at approximately four times the volume coverage speed of SS-CT. (orig.)

  7. Two-phase helical hepatic CT. Contrast-injection protocol, optimal timing and its usefulness in clinical cases

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Rie [Univ. of Occupational and Environmental Health, Kitakyushu, Fukuoka (Japan)

    1998-03-01

    The usefulness of two-phase helical computed tomography (CT) of the liver was evaluated in clinical cases. First, an optimal scanning protocol was determined using time-attenuation analysis. Monophasic dynamic CT was performed with 100 ml of contrast media (iodine 300 mg/ml) injected either at 3 ml/s or at 2 ml/s. Aortic, hepatic and portal time-attenuation curves were made for each protocol. The results showed that these two different injection protocols produce equivalent enhancements and that the injection rate of 2 ml/s is satisfactorily applicable to clinical cases. The first scanning (arterial phase) must be started 40-45 s after the beginning of the injection of contrast media and the second scanning (delayed phase) 80-120 s after the beginning of injection. Using these CT protocols, 327 cases were examined. In this study 83 hepatic lesions (hepatocellular carcinoma; HCC, n=29; suspected HCC, n=30; hemangioma, n=24) were evaluated. There were 15 HCCs smaller than 30 mm in diameter (71.4%) detected by either arterial phase or delayed phase alone. This result indicates that two-phase helical hepatic CT is very useful in the detection of small HCC. Particularly, four or 5 HCCs of less than 10 mm in size (80%) showed a hyperattenuation area in the arterial phase alone. HCCs which have sufficient vascularity were also easily demonstrated. However, this two-phase helical hepatic CT could not demonstrate 11 lesions (13.3%) with almost normal blood supply. In such cases the complementary role of ultrasound (US) seems to be important. Hence as a screening of hepatic mass lesions both CT and US are necessary. Most HCC could be differentiated from hemangioma by an enhancement pattern using this protocol. But the small liver lesions of less than 15 mm in size with homogeneous hyperattenuation in the arterial phase and isoattenuation in the delayed phase included HCC, hemangioma and metastatic tumors. (author)

  8. System for the analysis of whole-bone strength from helical CT images

    Science.gov (United States)

    Camp, Jon J.; Karwoski, Ronald A.; Stacy, Mahlon C.; Atkinson, Elizabeth J.; Khosla, Sundeep; Melton, L. Joseph; Riggs, B. Lawrence; Robb, Richard A.

    2004-04-01

    Osteoporosis affects an estimated 44 million Americans. This condition results from bone loss, but the measured change in bone mass does not fully account for the marked decrease in whole-bone structural integrity seen in osteoporosis. In order to study structural changes in bone mineral distribution due to normal ageing and osteoporosis, we have developed a method for progressive analysis of whole-bone mechanical integrity from helical CT images. The system provides rapid semi-automated alignment of femur and vertebrae volume images into standard anatomic reference planes, and calculates bone mineral density in any selected 3D sections of bone. Mineral density measures are obtained using both full-width-half-max contours and threshold-derived masks, and are obtained for cortical bone and trabecular bone separately. Biomechanical properties of the bone cross-section are also assessed, including the 2-D bending moment of the cortical bone region and the integrated flexural rigidity of the cortical region or whole-bone region in arbitrary planes. This method facilitates progressive refinement of the analysis protocol by separating the labor-intensive alignment and landmark selection process from the analysis process. As the analysis protocol evolves to include new measures, previously analyzed images can be automatically reanalyzed, using the image regions originally specified. Initial results show inverse correlation of indices of biomechanical bone strength with age, greater loss of bone strength in the lumbar spine than in the femoral neck, and more trabecular than cortical bone loss at both sites.

  9. High-resolution helical cone-beam micro-CT with theoretically-exact reconstruction from experimental data

    Energy Technology Data Exchange (ETDEWEB)

    Varslot, T.; Kingston, A.; Myers, G.; Sheppard, A. [Department of Applied Mathematics, Research School of Physics and Engineering, The Australian National University, Canberra, ACT 0200 (Australia)

    2011-10-15

    Purpose: In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, theoretically-exact helical CT is a viable option for high-resolution micro-CT imaging at high cone-angles ({approx}50 deg.). The elevated cone-angle enables better utilization of the available X-ray flux and therefore shorter image acquisition time than conventional micro-CT systems. Methods: By using the theoretically-exact Katsevich 1PI inversion formula, we are not restricted to a low-cone-angle regime; we can in theory obtain artefact-free reconstructions from projection data acquired at arbitrary high cone-angles. However, this reconstruction method is sensitive to misalignments in the tomographic data, which result in geometric distortion and streaking artefacts. We use a parametric model to quantify the deviation between the actual acquisition trajectory and an ideal helix, and use an autofocus method to estimate the relevant parameters. We define optimal units for each parameter, and use these to ensure consistent alignment accuracy across different cone-angles and different magnification factors. The tomographic image is obtained from a set of virtual projections in which software correction for hardware misalignment has been applied. Results: We make significant modifications to the autofocus method that allow this method to be used in helical micro-CT reconstruction, and show that these developments enable theoretically-exact reconstruction from experimental data using the Katsevich 1PI (K1PI) inversion formula. We further demonstrate how autofocus-corrected, theoretically-exact helical CT reduces the image acquisition time by an order of magnitude compared to

  10. A three-dimensional reconstruction of the temporal bone by the helical scanning CT and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Yonekawa, Hiroyuki; Ohashi, Masami; Miyashita, Souji; Gotoh, Mizuho; Nemoto, Satohiko; Kikuchi, Hideki (Azabu Triology Hospital, Sapporo (Japan)); Sakai, Noboru; Inuyama, Yukio

    1993-09-01

    The current availability of 3 dimensional (3-D) imaging from Computed Tomography (CT) has yielded new anatomical information and pre- and postoperative evaluations. However, little discussion as to the 3-D structural image of the temporal bone has been reported because conventional CT does provide sufficient data to produce such images. The helical scanning CT gathers continuous and multiple slice image data since it consists of an X-ray tube that continuously rotates around the patient while the patient moves continuously into the CT scanner. Thus, application of the helical scanning CT has made it possible to reconstruct 3-D images of the minute and complicated structure of the temporal bone. We evaluated 3-D images from 9 typical cases, examined from February to October 1992. As a result, we found that the 3-D images reconstructed with this system are useful for evaluation of the postoperative state of tympanoplasty, the diagnosis of anomalies of the bony labyrinth, and examining the extent of bone destruction induced by trauma, cholesteatoma, etc. (author).

  11. Radiological anatomy of the medial segment of the liver based on three-dimensional images reconstructed from helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Akihiro; Asano, Takehide [Chiba Univ. (Japan). School of Medicine; Ryu, Munemasa [and others

    1998-09-01

    Three-dimensional images of bile duct within the liver, portal vein and liver artery were reconstructed from helical CT. Helical CT was performed by bile duct contrasting CT, portal vein contrasting CT via artery (CTAP) and liver artery contrasting CT (CTA), respectively. The inside area was classified to 3 parts, S{sub 4}a, S{sub 4}b and S{sub 4}c from the stomach side as upper part, middle part and lower part. In each area, location of bile duct junction, portal vein branch divergence and artery branch divergence were examined. Nineteen of 25 of bile duct branch B{sub 4}a from S{sub 4}a part joined at upper part. And 17 of 17 portal vein branch P{sub 4}a to S{sub 4}a part diverged at upper part. Eight liver artery A{sub 4}a to S{sub 4}a part diverged at upper part entirely. Fifteen of 23 of B{sub 4}b diverged at middle part. As to twelve P{sub 4}b, 8 of them diverged at upper part, 3 of them diverged at middle part and 1 of them diverged from portal vein branch in front-right part. As to A{sub 4}b, one of them diverged at upper part, three of them diverged at middle part and one of them diverged from right liver artery. (K.H.)

  12. Diagnosis of nutcracker syndrome of the left renal vein. Value of the corticomedullary phase of helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Igari, Hidenori [Yokohama Comprehensive Care Continuum (Japan)

    2001-05-01

    The clinical significance of the corticomedullary phase of helical CT in the diagnosis of nutcracker syndrome of the left renal vein (LRV) was evaluated. A total of 38 patients with hematuria of unknown origin (12 men and 26 women, mean age 24 years [range: 18-32 years]) were examined by helical CT of the kidneys, retrograde left renal venography, and measurement of renocaval pressure gradients. The sensitivity and specificity of the corticomedullary and nephrographic phases of helical CT for detecting the nutcracker syndrome were determined. The nutcracker syndrome was diagnosed on the basis of the renography findings combined with pressure measurements in 19 patients: 12 with LRV hypertension and collateral veins, 1 with hypertension and no collateral veins, and 6 with collateral veins and normal pressure gradients or borderline hypertension. Both the corticomedullary- and nephrographic-phase images revealed distended LRVs in 26 (68%) of the 38 patients. The LRV mean attenuation values in the corticomedullary phase (164{+-}22 Hounsfield units [H], range: 138-209 H) was significantly greater (p<0.001) than in the nephrographic phase (80{+-}14 H, range: 62-100 H). During the corticomedullary phase, opacified blood from the renal vein was mixed with unopacified blood in the IVC. In the nephrographic phase, however, the IVC was enhanced homogeneously, but only slightly. Corticomedullary-phase imaging detected collateral veins that exhibited early enhancement, indicating retrograde flow from the LRVs in 15 out of 18 patients (83% of those with collateral veins), while the nephrographic-phase imaging revealed collateral veins in 8 patients (44% of those with collateral veins). The sensitivity and specificity of the corticomedullary-phase scan for detecting the nutcracker syndrome were 79% and 100%, respectively, as opposed to 42% and 100%, respectively, for the nephrographic phase. Retrograde flow from the LRV into the collateral veins in the corticomedullary phase is

  13. Effect of CT contrast on volumetric arc therapy planning (RapidArc and helical tomotherapy) for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Alan J.; Vora, Nayana [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States); Suh, Steve [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Liu, An, E-mail: aliu@coh.org [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Schultheiss, Timothy E. [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Wong, Jeffrey Y.C. [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States)

    2015-04-01

    The objectives of the study were to evaluate the effect of intravenous contrast in the dosimetry of helical tomotherapy and RapidArc treatment for head and neck cancer and determine if it is acceptable during the computed tomography (CT) simulation to acquire only CT with contrast for treatment planning of head and neck cancer. Overall, 5 patients with head and neck cancer (4 men and 1 woman) treated on helical tomotherapy were analyzed retrospectively. For each patient, 2 consecutive CT scans were performed. The first CT set was scanned before the contrast injection and secondary study set was scanned 45 seconds after contrast. The 2 CTs were autoregistered using the same Digital Imaging and Communications in Medicine coordinates. Tomotherapy and RapidArc plans were generated on 1 CT data set and subsequently copied to the second CT set. Dose calculation was performed, and dose difference was analyzed to evaluate the influence of intravenous contrast media. The dose matrix used for comparison included mean, minimum and maximum doses of planning target volume (PTV), PTV dose coverage, and V{sub 45} {sub Gy}, V{sub 30} {sub Gy}, and V{sub 20} {sub Gy} organ doses. Treatment planning on contrasted images generally showed a lower dose to both organs and target than plans on noncontrasted images. The doses for the points of interest placed in the organs and target rarely changed more than 2% in any patient. In conclusion, treatment planning using a contrasted image had insignificant effect on the dose to the organs and targets. In our opinion, only CT with contrast needs to be acquired during the CT simulation for head and neck cancer. Dose calculations performed on contrasted images can potentially underestimate the delivery dose slightly. However, the errors of planning on a contrasted image should not affect the result in clinically significant way.

  14. Axially extended-volume C-arm CT using a reverse helical trajectory in the interventional room.

    Science.gov (United States)

    Yu, Zhicong; Maier, Andreas; Lauritsch, Gunter; Vogt, Florian; Schonborn, Manfred; Kohler, Christoph; Hornegger, Joachim; Noo, Frederic

    2015-01-01

    C-arm computed tomography (CT) is an innovative technique that enables a C-arm system to generate 3-D images from a set of 2-D X-ray projections. This technique can reduce treatment-related complications and may improve interventional efficacy and safety. However, state-of-the-art C-arm systems rely on a circular short scan for data acquisition, which limits coverage in the axial direction. This limitation was reported as a problem in hepatic vascular interventions. To solve this problem, as well as to further extend the value of C-arm CT, axially extended-volume C-arm CT is needed. For example, such an extension would enable imaging the full aorta, the peripheral arteries or the spine in the interventional room, which is currently not feasible. In this paper, we demonstrate that performing long object imaging using a reverse helix is feasible in the interventional room. This demonstration involved developing a novel calibration method, assessing geometric repeatability, implementing a reconstruction method that applies to real reverse helical data, and quantitatively evaluating image quality. Our results show that: 1) the reverse helical trajectory can be implemented and reliably repeated on a multiaxis C-arm system; and 2) a long volume can be reconstructed with satisfactory image quality using reverse helical data.

  15. Imaging of Blood Flow in Cerebral Arteries with Dynamic Helical Computed Tomography Angiography (DHCTA) Using a 64-Row CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Pekkola, J.; Kangasniemi, M. (Helsinki Medical Imaging Center, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2009-08-15

    Background: Cerebral computed tomography angiography (CTA) depicts a structural image of intracranial arteries without providing much time-resolved information on blood flow dynamics. Current CT technology allows obtaining of rapidly repeated helical scans during the arterial contrast filling phase after an intravenous contrast injection. Purpose: To report our experience on dynamic CT imaging in determining the direction of contrast filling within proximal intracranial arteries of operated cerebral artery aneurysm patients. Such dynamic information can help detect vascular occlusion or severe spasm. The method is here referred to as dynamic helical CT angiography (DHCTA). Material and Methods: We retrospectively collected image and related technical data for 23 patients who underwent DHCTA and CTA during their first postoperative day after cerebral artery aneurysm surgery. For DHCTA, we had helically scanned a 4-cm tissue volume three times in succession with a 64-row CT scanner at intervals of 2.6 s during arterial contrast filling after an intravenous contrast injection. We assessed how well DHCTA succeeded in demonstrating the direction of contrast filling in the proximal intracranial arteries, evaluated clinically relevant structural information provided by DHCTA and CTA, and compared radiation doses for the two methods. Results: For 21 patients, DHCTA outlined the direction of contrast filling in proximal intracranial arteries. As to arterial spasm and residual filling of the operated aneurysm, CTA and DHCTA gave similar information. Radiation doses were higher (P<0.000001) for DHCTA than for CTA at 120 kV tube voltage. At 100 kV, the difference was smaller, but doses for DHCTA still exceeded (P<0.05) those for CTA. Conclusion: DHCTA gave dynamic information unobtainable with CTA and could prove useful in selected clinical settings

  16. 4D-Imaging of the lung: reproducibility of lesion size and displacement on helical CT, MRI, and cone beam CT in a ventilated ex vivo system.

    Science.gov (United States)

    Biederer, Juergen; Dinkel, Julien; Remmert, Gregor; Jetter, Siri; Nill, Simeon; Moser, Torsten; Bendl, Rolf; Thierfelder, Carsten; Fabel, Michael; Oelfke, Uwe; Bock, Michael; Plathow, Christian; Bolte, Hendrik; Welzel, Thomas; Hoffmann, Beata; Hartmann, Günter; Schlegel, Wolfgang; Debus, Jürgen; Heller, Martin; Kauczor, Hans-Ulrich

    2009-03-01

    Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24 x 10(2)/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution approximately 1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p CT]; 1.47/1.28 [MRI vs. CT/CBCT p CT vs. CBCT p CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.

  17. Lung Motion Model Validation Experiments, Free-Breathing Tissue Densitometry, and Ventilation Mapping using Fast Helical CT Imaging

    Science.gov (United States)

    Dou, Hsiang-Tai

    The uncertainties due to respiratory motion present significant challenges to accurate characterization of cancerous tissues both in terms of imaging and treatment. Currently available clinical lung imaging techniques are subject to inferior image quality and incorrect motion estimation, with consequences that can systematically impact the downstream treatment delivery and outcome. The main objective of this thesis is the development of the techniques of fast helical computed tomography (CT) imaging and deformable image registration for the radiotherapy applications in accurate breathing motion modeling, lung tissue density modeling and ventilation imaging. Fast helical CT scanning was performed on 64-slice CT scanner using the shortest available gantry rotation time and largest pitch value such that scanning of the thorax region amounts to just two seconds, which is less than typical breathing cycle in humans. The scanning was conducted under free breathing condition. Any portion of the lung anatomy undergoing such scanning protocol would be irradiated for only a quarter second, effectively removing any motion induced image artifacts. The resulting CT data were pristine volumetric images that record the lung tissue position and density in a fraction of the breathing cycle. Following our developed protocol, multiple fast helical CT scans were acquired to sample the tissue positions in different breathing states. To measure the tissue displacement, deformable image registration was performed that registers the non-reference images to the reference one. In modeling breathing motion, external breathing surrogate signal was recorded synchronously with the CT image slices. This allowed for the tissue-specific displacement to be modeled as parametrization of the recorded breathing signal using the 5D lung motion model. To assess the accuracy of the motion model in describing tissue position change, the model was used to simulate the original high-pitch helical CT scan

  18. Helical CT evaluation of the chemical composition of urinary tract calculi with a discriminant analysis of CT-attenuation values and density

    Energy Technology Data Exchange (ETDEWEB)

    Bellin, Marie-France; Meric, Jean-Baptiste [AP-HP, Department of Radiology, Hopital Paul-Brousse, Villejuif Cedex (France); Renard-Penna, Raphaelle; Grenier, Philippe [AP-HP, Department of Radiology, Hopital Pitie-Salpetriere, Paris Cedex 13 (France); Conort, Pierre; Richard, Francois [AP-HP, Department of Urology, Hopital Pitie-Salpetriere, Paris Cedex 13 (France); Bissery, Anne; Mallet, Alain [AP-HP, Department of Biostatistics, Hopital Pitie-Salpetriere, Paris Cedex 13 (France); Daudon, Michel [AP-HP, Department of Biochemistry, Hopital Necker, Paris Cedex 15 (France)

    2004-11-01

    The aim of this study was to evaluate the efficacy of helical CT using a combination of CT-attenuation values and visual assessment of stone density as well as discriminant linear analysis to predict the chemical composition of urinary calculi. One hundred human urinary calculi were obtained from a stone-analysis laboratory and placed in 20 excised pig kidneys. They were scanned at 80, 120 and 140 kV with 3-mm collimation. Average, highest and lowest CT-attenuation values and CT variability were recorded. The internal calculus structure was assessed using a wide window setting, and visual assessment of stone density was recorded. A stepwise discriminant linear analysis was performed. The following three variables were discriminant: highest CT-attenuation value, visual density, and highest CT-attenuation value/area ratio, all at 80 kV. The probability of correctly classifying stone composition with these three variables was 0.64, ranging from 0.54 for mixed calculi to 0.69 for pure calculi. The probabilities of correctly classifying calculus composition were: 0.91 for calcium oxalate monohydrate and brushite, 0.89 for cystine, 0.85 for uric acid, 0.11 for calcium oxalate dihydrate, 0.10 for hydroxyapatite, and 0.07 for struvite calculi. When the first two ranks of highest probability for the accurate classification of each calculus type were taken into account, 81% of the calculi were correctly classified. Assessment at 80 kV of the highest CT-attenuation value, visual density and the highest CT-attenuation value/area ratio accurately predicts the chemical composition of 64-81% of urinary calculi. When the first two ranks of highest probability for the accurate classification of each calculus type were taken into account, all cystine, calcium oxalate monohydrate and brushite calculi were correctly classified. (orig.)

  19. The purpose of this study is to determine the clinical usefulness of Valsalva maneuver (VM) to evaluate piriform-fossae lesions on helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Shoji; Yasuda, Shigeo; Kimura, Shinjiro; Ito, Hisao [Chiba Univ. (Japan). Hospital; Fujimoto, Hajime; Nasu, Katsuhiro; Motoori, Ken

    1997-07-01

    Forty-four patients who were suspected hypopharyngeal carcinoma underwent both conventional CT under quiet breath holding and helical CT under Valsalva maneuver (VMCT). All patients successfully performed Valsalva maneuver during image acquisition. Normal piriform fossae were dilated well under VM. Five fossae involved by hypopharyngeal carcinoma were poorly dilated on VMCT. In conclusion VMCT is a supportive method to evaluate piriform fossae. If piriform fossae lesions were suspected on conventional CT, VMCT should be performed. (author)

  20. Unusual presentation of a pancreatic insulinoma in helical CT and dynamic contrast-enhanced MR imaging: case report

    Energy Technology Data Exchange (ETDEWEB)

    Iglesias, A.; Arias, M.; Brasa, J. [Unidad de Resonancia Magnetica (Medtec), Hospital Xeral-Cies, Vigo (Spain); Casal, M. [Unidad de Radiologia Intervencionista, Hospital Xeral-Cies, Vigo (Spain); Paramo, C. [Servicio de Endocrinologia, Hospital Xeral-Cies, Vigo (Spain); Fiano, C. [Servicio de Anatomia Patologica, Hospital Xeral-Cies, Vigo (Spain)

    2001-06-01

    Insulinomas are pancreatic neoplasms that can be radiologically characterized typically because of their tendency to present intense and early contrast enhancement with a wash-out phenomenon. In this sense, we report an unusual case of a hypovascular solid pancreatic insulinoma confirmed with surgery and pathologic analysis, in a patient with normal serum insulin levels. In the two-phase helical CT, the mass behaved as a hypodense lesion with respect to the surrounding pancreatic parenchyma during the arterial phase and as a hypointense lesion during the dynamic contrast-enhanced MR imaging. Pathologic examination demonstrated a hypercellular tumor with poor vascularization of intervening stroma which showed prominent amyloid deposits. (orig.)

  1. A clinical study concerning hepatic arterial dominant phase and arrival time of contrast media on helical dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsubara, Susumu; Uchida, Chiharu; Sato, Sei; Ishida, Junichi; Masuya, Ryozo [Hiroshima Teishin Hospital (Japan); Makiguchi, Mako [Radiation Effects Research Foundation, Hiroshima (Japan); Kanamori, Isao [Gifu Coll. of Medical Technology (Japan)

    2001-10-01

    Hepatic arterial dominant phase in helical dynamic CT was optimized by measuring the arrival time of contrast media (ATCM) with time-density curve (TDC). Subjects were 1005 patients (577 males and 428 females) and 98 nodules diagnosed as advanced hepatocellular carcinoma (HCC). The CT was done with Toshiba 4MHU X-vision SP, ultrasonography with Toshiba SSH-160A and automatic infusion of the contrast medium, iopamidol or iohexol, with Nemotokyorindo Autoenhance A-50. ATCM was found correlated with pulse rate and with arterial diameter, and significantly different between the sex. Elevation slope of TDC was suggested to be made constant by a defined infusion time of the dose corrected by body weight. Fluctuation of TDC among patients , when normalized by ATCM, was found smaller and the TDC was suggested to be useful for better imaging of HCC of less than 10 mm diameter. (K.H.)

  2. Fuzzy Clustering Applied to ROI Detection in Helical Thoracic CT Scans with a New Proposal and Variants.

    Science.gov (United States)

    Castro, Alfonso; Rey, Alberto; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro

    2016-01-01

    The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium).

  3. Prospectively ECG Gated CT pulmonary angiography versus helical ungated CT pulmonary angiography: Impact on cardiac related motion artifacts and patient radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Shuman, William P., E-mail: wshuman@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Leipsic, Jonathon A., E-mail: JLeipsic@providencehealth.bc.ca [University of British Columbia and St. Paul' s Hospital, Department of Radiology, 1081 Burrard Street, Vancouver, BC, V6Z1Y6 (Canada); Busey, Janet M., E-mail: jbonny@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Green, Douglas E., E-mail: dougreen@uw.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Pipavath, Sudhakar N., E-mail: snjp@u.wwashington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Hague, Cameron J., E-mail: cjhague@interchange.ubc.ca [University of British Columbia and St. Paul' s Hospital, Department of Radiology, 1081 Burrard Street, Vancouver, BC, V6Z1Y6 (Canada); Koprowicz, Kent M., E-mail: kentk@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States)

    2012-09-15

    Objective: To compare prospectively ECG gated CT pulmonary angiography (CTPA) with routine helical ungated CTPA for cardiac related motion artifacts and patient radiation dose. Subjects and methods: Twenty patients with signs and symptoms suspicious for pulmonary embolism and who had a heart rate below 85 were scanned with prospectively ECG gated CTPA. These gated exams were matched for several clinical parameters to exams from twenty similar clinical patients scanned with routine ungated helical CTPA. Three blinded independent reviewers subjectively evaluated all exams for overall pulmonary artery enhancement and for several cardiac motion related artifacts, including vessel blurring, intravascular shading, and double line. Reviewers also measured pulmonary artery intravascular density and image noise. Patient radiation dose for each technique was compared. Fourteen clinical prospectively ECG gated CTPA exams from a second institution were evaluated for the same parameters. Results: Prospectively ECG gated CTPA resulted in significantly decreased motion-related image artifact scores in lung segments adjacent to the heart compared to ungated CTPA. Measured image noise was not significantly different between the two types of CTPA exams. Effective dose was 28% less for prospectively ECG gated CTPA (4.9 mSv versus 6.8 mSv, p = 0.02). Similar results were found in the prospectively ECG gated exams from the second institution. Conclusion: Compared to routine helical ungated CTPA, prospectively ECG gated CTPA may result in less cardiac related motion artifact in lung segments adjacent to the heart and significantly less patient radiation dose.

  4. Early clinical phase of patient's management after polytrauma using 1- and 4-slice helical CT; Fruehes klinisches Management nach Polytrauma mit 1- und 4-Schicht-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Kloeppel, R.; Kahn, T. [Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Schreiter, D. [Chirurgische Intensivtherapieabteilung, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany); Dietrich, J. [Abt. Neuroradiologie der Klinik und Poliklinik fuer Diagnostische Radiologie, Universitaetsklinikum Leipzig (Germany); Josten, C. [Klinik und Poliklinik fuer Unfall- und Wiederherstellungschirurgie, Zentrum fuer Chirurgie, Universitaetsklinikum Leipzig (Germany)

    2002-07-01

    In the early clinical phase the comprehensive imaging of patients with multiple trauma using helical CT is already established. Aim of this study was to assess whether MSCT may improve the patient management and the diagnostic results.The procedure is designed as follows: after life-thretening treatment x-ray of chest and ultrasound are carried out in the emergency room. Then the patient is moved to CT. From 1998 to december 2000 241 patients were examined using a single slice helical CT (Somatom plus 4), in 2001 79 patients using a 4-slice helical CT (Somatom VZ, Siemens Med.Sol.). After CT selected radiograms of the extremities were taken.359 of 360 procedures were carried out successfully. Excluding 1 case (death during 1-sl. h CT) all relevant lesions of head, neck, and body were diagnosed. Although the patients had an injury severity score of {approx}30. The change from 1slice-helical CT to 4 slice-helical CT allowed us to reduce the stay in the CT room from 28 to 16 min. The total lethality decreased by {approx}4%.Advantages for the patient arose from the standardized examination protocol using multislice CT. If integrated in an interdisciplinary management concept, it is a good compromise between examination time, comprehensive diagnostic imaging, life-saving therapeutic procedures, and therapy planning. (orig.) [German] Die klinische Erstversorgung Polytraumatisierter schliesst inzwischen in vielen Unfallkliniken den fruehzeitigen Einsatz der Spiral-CT ein. Kann die neuerlich eingefuehrte Mehrschicht-Spiral-CT Ergebnisse und Patientenmanagement weiter verbessern?Nach lebensrettenden Sofortmassnahmen, Thoraxroentgen und Notsonographie im Schockraum erfolgte die CT: Von 1998-2000 wurden 241 Patienten mit einem 1-Schicht-Spiral-CT (Somatom plus 4) und in 2001 79 Patienten mit einem 4-Schicht-Spiral-CT (Somatom VZ, beide Siemens Med. Sol.) untersucht. Klinisch ausgewaehlte Extremitaetenaufnahmen wurden ergaenzt.359 von 360 Untersuchungen verliefen erfolgreich

  5. The prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint in patients with mandibular prognathism without internal derangement. MR and helical CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takafumi; Ito, Jusuke; Tanaka, Rei; Koyama, Jun-ichi; Kobayashi, Fukiko [Niigata Univ. (Japan). Graduate School of Medical and Dental Sciences

    2002-06-01

    The aim of this study was to assess the prevalence of erosive osseous changes of the articular eminence in the temporomandibular joint without internal derangement. Sixty joints of 30 consecutive patients with mandibular prognathism were evaluated with both MR imaging and helical CT. On MPR images obtained with helical CT, erosive osseous changes of the articular eminence were observed in 18 joints (30%) of 13 patients. None of the joints studied demonstrated an osseous change in the mandibular condyle. MR imaging failed to detect erosive osseous changes of the articular eminence in all of the joints studied. In conclusion, MPR images obtained with helical CT were of value to detect erosive osseous changes of the articular eminence. (author)

  6. [The effect of the severity of congenital pectus excavatum on the cardiac morphology in children: evaluation with multislice helical CT].

    Science.gov (United States)

    Lu, Tao; Deng, Kaihong

    2013-12-01

    This paper is aimed to evaluate the CT manifestation of congenital pectus excavatum and its effect on the cardiac morphology. CT features of 34 children with pectus excavatum were retrospectively reviewed. The Haller index (HI), CT depression index (CTDI), cardiac rotation angle (CRA), pulmonary vein angle (PVA), cardiac compression index (CCI) and cardiac asymmetry index (CAI) were measured from the images on the PACS system. The relationships among these indexes were evaluated. The HI was 4.12 +/- 1.48, the CTDI was 2.39+/- 0.70, CRA was (53.52 +/- 7.68) degrees, PVA was (66.51 +/- 11.02) degrees, CCI was 2.43 +/- 0.95, and CAI was 1.55 +/- 0.56. There was statistical significance of CCI and CAI between children with severe or slight pectus excavatum. The HI and CTDI were positively related with CCI and CAI respectively, whereas there was no statistical significance of CRA and PVA between children with severe or slight pectus excavatum. There was no statistical significance of HI, CTDI, CRA, PVA, CCI and CAI among different age groups. The morphological change of the heart compressed in children with pectus excavatum can be accurately evaluated by multislice helical CT.

  7. Low-dose helical computed tomography (CT) in the perioperative workup of adolescent idiopathic scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Abul-Kasim, Kasim; Overgaard, Angelica; Maly, Pavel [Malmoe University Hospital, Department of Radiology, Section of Neuroradiology, University of Lund, Malmoe (Sweden); Ohlin, Acke [Malmoe University Hospital, Department of Orthopaedic Surgery, University of Lund, Malmoe (Sweden); Gunnarsson, Mikael [Malmoe University Hospital, Department of Radiation Physics, University of Lund, Malmoe (Sweden); Sundgren, Pia C. [University of Michigan Health Systems, Department of Radiology, Division of Neuroradiology, Ann Arbor (United States)

    2009-03-15

    The study aims were to estimate the radiation dose in patients examined with low dose spine CT and to compare it with that received by patients undergoing standard CT for trauma of the same region, as well as to evaluate the impact of dose reduction on image quality. Radiation doses in 113 consecutive low dose spine CTs were compared with those in 127 CTs for trauma. The inter- and intraobserver agreement in measurements of pedicular width, and vertebral rotation, measurements of signal-to-noise ratio and assessment of hardware status were the indicators in the evaluation of image quality. The effective dose of the low dose spine CT (0.37 mSv) was 20 times lower than that of a standard CT for trauma (13.09 mSv). This dose reduction conveyed no impact on image quality. This low dose spine CT protocol allows detailed evaluation that is necessary for preoperative planning and postoperative evaluation. (orig.)

  8. Correlation of VEGF with contrast enhancement on dual-phase dynamic helical CT in liver tumors: preliminary study.

    Science.gov (United States)

    Kwak, B. K.; Shim, H. J.; Park, U. S.; Lee, T. J.; Paeng, S. S.; Lee, C. J.; Lim, H. K.; Park, C. K.

    2001-01-01

    The purpose of this preliminary study is to elucidate that vascular endothelial growth factor (VEGF) influences contrast enhancement of hepatic tumors on computed tomography (CT). Fourteen patients with hepatic tumors (11 hepatocellular carcinomas; 3 metastatic cancers) underwent a dual-phase dynamic helical CT or computed tomographic hepatic arteriography. The attenuation of each mass was determined as hyperattenuation, isoattenuation or hypoattenuation with respect to the adjacent nontumorous parenchyma. Gun-needle biopsy was done for each tumor, and paraffin sections were immunostained with anti- VEGF antibody by the avidin-biotin-peroxidase complex method. The pathologic grade was made by intensity (1 +, 2+, 3+) and area (+/-, 1 +, 2+). The tumor ranged 2.0-14.0 cm in size (mean, 5.8 cm). In arterial phase, the intensity was not correlated with the degree of enhancement (p=0.086). However, the correlation between the attenuation value of hepatic arterial phase and the area of positive tumor cells was statistically significant (p=0.002). VEGF may be the factor that enhances the hepatic mass with water-soluble iodinated contrast agent in CT. PMID:11289406

  9. Evaluation of exposure dose reduction in multislice CT coronary angiography (MS-CTA) with prospective ECG-gated helical scan

    Science.gov (United States)

    Ota, Takamasa; Tsuyuki, Masaharu; Okumura, Miwa; Sano, Tomonari; Kondo, Takeshi; Takase, Shinichi

    2008-03-01

    A novel low-dose ECG-gated helical scan method to investigate coronary artery diseases was developed. This method uses a high pitch for scanning (based on the patient's heart rate) and X-rays are generated only during the optimal cardiac phases. The dose reduction was obtained using a two-level approach: 1) To use a 64-slice CT scanner (Aquilion, Toshiba, Otawara, Tochigi, Japan) with a scan speed of 0.35 s/rot. to helically scan the heart at a high pitch based on the patient's heart rate. By changing the pitch from the conventional 0.175 to 0.271 for a heart rate of 60 bpm, the exposure dose was reduced to 65%. 2) To employ tube current gating that predicts the timing of optimal cardiac phases from the previous cardiac cycle and generates X-rays only during the required cardiac phases. The combination of high speed scanning with a high pitch and appropriate X-ray generation only in the cardiac phases from 60% to 90% allows the exposure dose to be reduced to 5.6 mSv for patients with a heart rate lower than 65 bpm. This is a dose reduction of approximately 70% compared to the conventional scanning method recommended by the manufacturer when segmental reconstruction is considered. This low-dose protocol seamlessly allows for wide scan ranges (e.g., aortic dissection) with the benefits of ECG-gated helical scanning: smooth continuity for longitudinal direction and utilization of data from all cardiac cycles.

  10. Bladder tumors:dynamic contrast-enhanced axial imaging, multiplanar reformation, three-dimensional reconstruction and virtual cystoscopy using helical CT

    Institute of Scientific and Technical Information of China (English)

    王东; 张挽时; 熊明辉; 喻敏; 徐家兴

    2004-01-01

    Background There have been few studies to evaluate the effects of helical CT on bladder tumor. This study was to evaluate the clinical applications of helical CT dynamic contrast-enhanced axial imaging, multiplanar reformation (MPR), three-dimensional (3D) reconstruction and virtual cystoscopy (CTVC) in bladder tumors. Methods The precontrast and four-phase postcontrast helical CT scans were performed in 42 patients with bladder tumors confirmed by conventional cystoscopy and pathology. MPR, 3D and CTVC images were generated from the volumetric data of the excretory phase. The results were then compared with the findings of conventional cystoscopy and surgery in a double-blinded mode. Results The sensitivity of the axial, 3D and CTVC images in detecting the bladder tumors were 90.8%, 76.9% and 95.4% respectively. The dynamic contrast-enhanced axial images could provide excellent intramural and extravesical information, and the accuracy in preoperative tumor staging was 87.7%. MPR could directly demonstrate the origin and extravesical invasions of the tumors and their relation to the ureter. 3D and CTVC images were useful for displaying the surface morphology of the tumor and the relationship between the tumor and the ureteric orifices, whereas CTVC could depict the tumors smaller than 5 mm that were not seen on the axial images.Conclusions The combination of axial, MPR, 3D and CTVC images with helical CT can provide comprehensive information on bladder tumor.

  11. Role and pitfalls of hepatic helical multi-phase CT scanning in differential diagnosis of small hemangioma and small hepatocellular carcinoma

    OpenAIRE

    Yan, Fu-Hua; Zeng, Meng-su; Zhou, Kang-Rong

    1998-01-01

    AIM: To compare and analyze the contrast enhancement appearance of small hemangioma (SHHE) and small hepatocellular carcinoma (SHCC) with helical multi-phase CT scanning so as to determine their roles and pitfalls in the differential diagnosis of SHHE and SHCC.

  12. 螺旋CT双期扫描对小肝癌的诊断%Diagnosis of SHCC with dual-phase helical CT

    Institute of Scientific and Technical Information of China (English)

    毕志德; 施承达

    2001-01-01

    目的应用螺旋CT行肝动脉期与门静脉期双期扫描分析小肝癌的诊断特征。方法18例小肝癌患者行双期扫描,观察各期的表现,进行分类。结果18例小肝癌中双期表现并不相同,可分为5类。结论螺旋CT肝双期扫描充分反映了小肝癌的血供特点,并能根据其特有表现与血管瘤、转移性肝癌等相鉴别。对小肝癌的检出有了明显提高。%Objective The arterial phase and portal venous phase scan with helical CT was applied to analyze the characteristic of small hepatocellular carcinomas (SHCC). Methods Dual-phase helical CT of the liver was performed on 18 patients with SHCC. The appearances of SHCC in both phases were investigated. Results The appearances of 18 SHCC were different and classified into 5 types. Dual-phase helical CT could reflect blood supply of SHCC. Conclusion Dual-phase helical CT could help to diagnose SHCC.

  13. Helical CT findings and clinicopathologic featuresin malignant gastrointestinal stromal tumors: the correlation between radiologic appearance and malignant potential

    Institute of Scientific and Technical Information of China (English)

    Zhifeng Xu; Aizhen Pan; Fang Yong; Yingyu Chen; Bin Li; Qiang Gao; Renhua Wu

    2011-01-01

    Objective: In this pictorial essay, we described the clinical, pathologic, and computed tomographic (CT) findings of malignant gastrointestinal stromal tumors (MGISTs) and attempt to establish the correlation between radiologic appearance and malignant potential. Methods: This retrospective analysis included 20 patients receiving treatment for MGIST between 2008 and 2010. The diagnosis was established by pathology and immunohistochemistry. All these patients underwent pre-operative CT. Clinical presentation, pathology and CT images were analyzed. Helical CT images were reviewed for morpho-logic features such as tumor size, number and location, tumor margins, necrosis, degree of enhancement and metastasis. Results: Gastrointestinal bleeding, abdominal pain and discomfort, and without clinical symptom were common findings and were observed in 9 (45%), 6 (30%), and 5 (25%) of the 20 patients. 8 (40%) tumors were located in stomach, and 10 (50%), 1 (5%) and 1 (5%) were located in small intestine, mesentery and peritoneum, respectively. Male to female ratio was about 1:2. The size of MGIST ranged from 2.6 cm to 17.5 cm with a mean of 8.7 cm. All tumors density was inhomogeneous and heterogeneous enhancement. MGISTs with highly malignant located in small intestine were about 30% higher than stomach. The "satellite" tumours were found in 6 cases with high malignant risk. 7 cases were suffered from liver metastasis, and 4 cases went with seeding into the abdominal cavity, 1 cases went with lymph node metastasis. Histologically, 19 cases (95%) were of spindle cell type. Immunohistochemical stains demonstrated a strong positivity for both c-kit (CD117) and CD34s enhancement in 19 (95%). Conclusion: Clinical expression is varied in MGIST patients. Female might be predominance in MGIST. The GISTs located in small intestine would tend to be more aggressive. The satellite tumours, necrosis and cystic degeneration were strongly benefit for MGIST diagnosis. Furthermore, intestinal

  14. Intraductal papillary mucinous neoplasms of the pancreas: Correlation of helical CT features with pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yu; Lin Xiaozhu; Upadhyaya, Manavendra; Song Qi [Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine (China); Chen Kemin, E-mail: keminchen@126.com [Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine (China)

    2010-11-15

    Objective: To evaluate the CT features of intraductal papillary mucinous neoplasms of the pancreas (IPMNs), and to compare with pathological findings in order to identify CT features that can be helpful in differentiating benign IPMNs from malignant IPMNs. Materials and methods: The CT findings in 25 patients were reviewed for tumor location, tumor type, dilatation of the main pancreatic duct (MPD), MPD involvement, mural node or solid attenuating component, tumor size in branch duct or mixed duct type, dilatation of common bile duct (CBD) and invasion of surrounding structures. The data was subjected to Chi-Square Tests or Fisher's Exact Test using SPSS13.0 software with p value < 0.05 indicating significant statistical difference. Results: Presence of mural node or solid enhancing component, size of mural node or solid enhancing component {>=}7 mm, dilatation of CBD was more common in malignant IPMNs (p < 0.05). None of tumor location, tumor type, dilatation of MPD, MPD involvement, tumor size, and invasion of surrounding structures was statistically significant in differentiating benign from malignant IPMNs. Conclusions: CT features suggestive of malignant or invasive IPMNs include presence of mural node or solid enhancing component, size of mural node or solid enhancing component {>=}7 mm, and dilatation of CBD.

  15. Diagnosis of lung embolism by V / Q scintigraphy. Pt. 3. Comparison with multislice-helical CT; V / Q-Szintigrafie zur Diagnostik der Lungenembolie. T. 3. Vergleich mit der Mehrzeilen-Spiral-CT

    Energy Technology Data Exchange (ETDEWEB)

    Schuemichen, C. [Rostock Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2008-12-15

    V / Q scintigraphy can be seen to be equal in many areas to the more modern multislice-helical CT in detecting acute pulmonary embolism and even to be superior with respect to sensitivity. Multislice-helical CT recognizes central emboli with high sensitivity and specificity, but deficits still remain in detecting peripheral embolisms, despite methodical improvements (increase up to 64 slices). Especially measured on the outcome, the overall sensitivity is still too low (ca. 75 %), the reason for this lies less in the image quality than in the evaluation. V / Q scintigraphy has deficits in detecting central emboli which either have no hemodynamic effects or are only partially occluding. Measured on the outsome, the overall sensitivity is still excellent, the number of symptomatic and fatal late embolisms in scintigraphically normal, untreated patients tends toward zero. Decisive for the prognosis are thus embolisms with hemodynamic effects in primary diagnostics. Unlike V / Q scintigraphy, multislice-helical CT also recognizes extrapulmonary diseases as alternative diagnoses, among these aortic dissection. The risk of tumor induction following radiation exposure is higher with multislice-helical CT than with V / Q scintigraphy by more than one order of magnitude. (orig.)

  16. Unenhanced helical CT in the evaluation of the urinary tract in children and young adults following urinary tract reconstruction: comparison with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.T.; Elder, J.S.; Sivit, C.J.; Applegate, K.E. [Dept. of Radiology, Rainbow Babies and Children' s Hospital, Cleveland, OH (United States)

    2001-03-01

    Purpose. To compare the accuracy of unenhanced, helical CT with sonography for the detection of complications of urinary tract reconstruction. Materials and methods. Forty-six kidneys in 24 patients were examined with CT and sonography. All scans were assessed for ease of renal visualization, presence of renal, ureteral, and bladder calculi, renal scars, hydronephrosis, and abdominal wall hernia. The results of both imaging modalities were independently reported. Results. CT provided excellent visualization of all 46 kidneys, while sonography provided poor visualization of 8 kidneys (17 %) (P < 0.001). CT detected calculi in 10 kidneys, 1 ureter, and 7 bladders. Sonography detected calculi in only 2 kidneys, and 2 bladders. Overall, CT detected significantly more calculi than US (18 vs 4, P = 0.01). CT detected scarring in 15 kidneys, while sonography detected scarring in 10. Hydronephrosis was detected in 6 kidneys by CT and in 8 kidneys by sonography. Three abdominal wall hernias were seen at CT that were not seen at sonography. Conclusion. CT is superior to sonography for the detection of urinary tract calculi and renal scarring. CT will demonstrate abdominal wall hernias that are unsuspected. (orig.)

  17. A qualitative diagnosis of stapes lesions by helical 3-dimensional CT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaue, Akifumi; Yamanaka, Noboru; Kuki, Kiyonori [Wakayama Medical Coll. (Japan); Nishimura, Michihiko [Koyo Hospital, Wakayama (Japan)

    2001-12-01

    To evaluate the usefulness of 3D-CT combined with super-selective stapes's image processing (3D-SS) for the qualitative diagnosis of stapes lesions, a new parameter, the crus index, was designed and applied to CT image diagnosis of conductive hearing loss. The crus index was designed as a new parameter indicating the average of changing rate of cross section area of crus image when the lower thresholed of CT window width reduced by 100 H.U.. The crus index was calculated with 3D-SS in 5 ears with otosclerosis, in 5 ears with eroded long process of incus or crus of stapes, an ear with facial neurinoma (susp), an ear with soft density tissue on only stapes and 6 control ears and the diagnostic usefulness was evaluated as comparing the intra-/post-operative diagnosis. The crus index was significantly higher in ears with eroded long process of incus or crus of stapes (3.58+1.36) than otosclerosis (1.33+0.35) or controls (1.44+0.3). These data suggest that the crus index using 3D-SS may be a useful parameter in diagnosing conductive hearing loss. (author)

  18. Detection of small hepatocellular carcinoma: Comparison of dynamic enhancement magnetic resonance imaging and multiphase multirow-detector helical CT scanning

    Institute of Scientific and Technical Information of China (English)

    Hong Zhao; Jin-Lin Yao; Ying Wang; Kang-Rong Zhou

    2007-01-01

    AIM: To compare the gadolinium-enhanced multiphase dynamic magnetic resonance imaging (MRI) and multiphase multirow-detector helical CT (MDCT)scanning for detection of small hepatocellular carcinoma (HCC).METHODS: MDCT scanning and baseline MRI with SE T1-WI and T2-WI sequence combined with FMPSPGR sequence were performed in 37 patients with 43 small HCCs. Receiver operating characteristic (ROC) curves were plotted to analyze the results for modality.RESULTS: The areas below ROC curve (Az) were calculated. There was no statistical difference in dynamic enhancement MDCT and MRI. The detection rate of small HCC was 97.5%-97.6% on multiphase MDCT scanning and 90.7%-94.7% on MRI, respectively. The sensitivity of detection for small HCC on MDCT scanning was higher than that on dynamic enhancement MRI. The sensitivity of detection for minute HCC (tumor diameter ≤ 1 cm)was 90.0%-95.0% on MDCT scanning and 70.0%-85.0% on MRI, respectively.CONCLUSION: MDCT scanning should be performed for early detection and effective treatment of small HCC in patients with chronic hepatitis and cirrhosis during follow-up.

  19. Evaluation of tumor detection and peak hepatic contrast enhancement in the portal dominant phase of two-phase helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Kazuhiro; Sakurada, Akira; Baba, Seiko; Ishida, Jirou; Kakizaki, Dai; Abe, Kimihiko [Tokyo Medical Coll. (Japan)

    1997-11-01

    We evaluated the portal dominant phase of two-phase helical CT. The livers of 203 (112 cirrhotic and 91 non-cirrhotic) patients were examined. Three protocols were performed in succession in three consecutive periods. In the first period 90 ml iohexol (300 mgI/ml) (300/90) was employed. In the second, 120 ml ioversol (240 mgI/ml) (240/120) and in the third 120 ml iomeprol (300 mgI/ml) (300/120) were given. The injection flow rate was 3 ml/sec. Scanning started 25 sec (arterial dominant phase) and 75 sec (portal dominant phase) after the beginning of contrast medium injection. In cirrhotic patients we evaluated whether the peak hepatic contrast enhancement (PHCE) was acquired or not. Among the 203 patients those 48 cases clinically diagnosed as hepatocellular carcinoma were examined in terms of tumor detection. The PHCE for each protocol showed no significant difference in the cirrhotic and non-cirrhotic groups. The presence of portosystemic shunt (P-S shunt) did not affect the PHCE in cirrhotic patients. The peak times were significantly different in cases with or without P-S shunt (p=.0004). Concerning tumor detection, the portal dominant phase was inferior to the arterial dominant phase (p=.00013) and equivalent to the delayed phase (p=.056). (author)

  20. Approximations of noise covariance in multi-slice helical CT scans: impact on lung nodule size estimation.

    Science.gov (United States)

    Zeng, Rongping; Petrick, Nicholas; Gavrielides, Marios A; Myers, Kyle J

    2011-10-07

    Multi-slice computed tomography (MSCT) scanners have become popular volumetric imaging tools. Deterministic and random properties of the resulting CT scans have been studied in the literature. Due to the large number of voxels in the three-dimensional (3D) volumetric dataset, full characterization of the noise covariance in MSCT scans is difficult to tackle. However, as usage of such datasets for quantitative disease diagnosis grows, so does the importance of understanding the noise properties because of their effect on the accuracy of the clinical outcome. The goal of this work is to study noise covariance in the helical MSCT volumetric dataset. We explore possible approximations to the noise covariance matrix with reduced degrees of freedom, including voxel-based variance, one-dimensional (1D) correlation, two-dimensional (2D) in-plane correlation and the noise power spectrum (NPS). We further examine the effect of various noise covariance models on the accuracy of a prewhitening matched filter nodule size estimation strategy. Our simulation results suggest that the 1D longitudinal, 2D in-plane and NPS prewhitening approaches can improve the performance of nodule size estimation algorithms. When taking into account computational costs in determining noise characterizations, the NPS model may be the most efficient approximation to the MSCT noise covariance matrix.

  1. Coronary artery calcification detected by a mobile helical CT unit in a mass screening. The frequency and relationship to coronary risk factors and coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Itani, Yasutaka; Watanabe, Shigeru; Masuda, Yoshiaki [Chiba Univ. (Japan). School of Medicine; Hanamura, Kazuhisa; Asakura, Kazuhiro; Sone, Shusuke; Sunami, Yuko; Shimura, Akimitsu; Miyamoto, Tadaaki

    2001-06-01

    A strong relationship is known to exist between coronary artery disease (CAD) and coronary artery calcification (CAC) detected by CT. In this study, we investigated the frequency of CAC and the relationship between coronary risk factors, CAD and CAC in a mass screening using a mobile helical CT unit. The total number of participants was 10008 people undergoing a medical examination for lung cancer and tuberculosis using a mobile helical CT unit. We measured the CT density of the coronary artery to detect CAC. The CT density threshold for determining CAC was above +110HU. The frequency of CAC was 16.0% in the overall patient population and significantly higher in males than in females (20.6% vs 10.7%). Frequency increased with age in both genders. Hypertension and diabetes mellitus were significantly related to CAC. Smoking showed a correlation with CAC only in males. A significant relationship was observed between CAD and CAC in males. In particular, the relationship between them was strongest in males under 60 years of age. Furthermore, the odds ratio of CAC in predicting CAD increased with increasing risk factors in both genders. (author)

  2. Multiple renal aspergillus abscesses in an AIDS patient: contrast-enhanced helical CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Heussel, C.P.; Kauczor, H.U.; Thelen, M. [Dept. of Radiology, Johannes Gutenberg Univ., Mainz (Germany); Heussel, G. [Dept. of Internal Medicine, Johannes Gutenberg Univ., Mainz (Germany); Jahn, B. [Inst. of Microbiology, Johannes Gutenberg Univ., Mainz (Germany)

    1999-05-01

    Renal insufficiency or allergic reactions for X-ray contrast agents are frequent limitations in immunocompromised hosts such as neutropenic or AIDS patients. Due to a better tolerance of contrast agents in MRI, this technique is well suited for investigation of parenchymal organs. We demonstrate an allergic AIDS patient who presented with fever and flank pain. At sonography, anechoic renal lesions were supposed to be non-complicated cysts; however, on T2-weighted MRI, the center was of high signal. Dynamic contrast-enhanced MRI of the kidneys demonstrated an enhancing rim with ill-defined margins. The lesions were supposed to be multiple bilateral abscesses. Due to the multiple dynamic contrast series, a delayed enhancement of renal parenchyma was detectable adjacent to the lesion. This was suggested as accompanying local pyelonephritis and an infectious etiology became more reliable. Aspergillus fumigatus was identified by CT-guided biopsy as the underlying microorganism. The MR appearance of this manifestation has not been described previously. (orig.) With 5 figs., 15 refs.

  3. Multislice helical CT (MSCT) for mid-facial trauma: optimization of parameters for scanning and reconstruction; Mehrschicht-Spiral-CT (MSCT) beim Mittelgesichtstrauma: Optimierung der Aufnahme- und Rekonstruktionsparameter

    Energy Technology Data Exchange (ETDEWEB)

    Dammert, S.; Funke, M.; Obernauer, S.; Grabbe, E. [Abt. Roentgendiagnostik I, Georg-August-Univ. Goettingen (Germany); Merten, H.A. [Abt. fuer Mund-, Kiefer- und Gesichtschirurgie, Georg-August-Univ. Goettingen (Germany)

    2002-07-01

    Purpose: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions. Material and Methods: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures. Results: The best image quality was obtained with a collimation of 4 x 1.25 mm and a - table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66). Conclusions: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary. (orig.) [German] Zielsetzung: Verbesserung der Aufnahme- und Rekonstruktionsparameter in der Mehrschicht Spiral-CT (MSCT) zur Untersuchung des knoechernen Mittelgesichtes in verschiedenen Ebenen. Material und Methode: Ein anthropomorphes Schaedel-Phantom wurde in axialer Schichtfuehrung mit einem MSCT untersucht, wobei die Kollimation (1,25 - 2,5 mm), der Tischvorschubfaktor (Pitch 3 - 6) und der Roehrenstrom (20 - 200 mA) systematisch variiert wurden. Aus den Volumendatensaetzen wurden jeweils koronare und parasagittale Sekundaerreformationen mit unterschiedlichen

  4. [First diagnostic choice in patients with high clinical suspicion of pulmonary thromboembolism: helical CT or ventilation/perfusion pulmonary scintigraphy?].

    Science.gov (United States)

    Ferrán, N; Martín-Comín, J; Bajén, M; Carrera, D; Mora, J; Ricart, Y; Sánchez, F; Mast, R

    2005-01-01

    Comparative analysis about helical CT (ThC) vs ventilation-perfusion pulmonary scintigraphy (V/P Sc) diagnosis effectiveness, as a first diagnosis technique in patients with high clinical suspicion of pulmonary thromboembolism (PT). Prospective study of 30 patients with high clinical suspicion and high Dimer-D levels (> 250 microg/l). The diagnosis was defined as anticoagulant therapeutic prescription and posterior clinical evolution. V/P Sc were performed to each patient within the next 48 h (an average of 14.8 h) after TCh, without anticoagulant treatment. We classified the scintigrams according to the PIOPED criteria and hTC images as positive, negative and indeterminated. In sixteen patients final diagnosis was PT: in 9 both techniques were positive; in 5 scintigraphy was positive with normal hTC and in 1, hTC was normal with negative scintigraphy. The last case was an indeterminated hTC with negative scintigraphy. In fourteen patients, final diagnosis was non-PT: in 6 both techniques were negative; in 7 scintigraphy was negative with positive hTC and in 1, both results were indeterminated. The sensitivity, specificity, positive predictive value, negative predictive value and efficiency were respectively 87.5, 100, 100, 87.5 and 93 % for V/P Sc and 62, 50, 58.8, 53.8 and 53 % for TCh. V/P Sc has better PT diagnosis reliability. It is recommended to do V/P Sc in all patients with high clinical suspicion of PT.

  5. CT imaging before transcatheter aortic valve implantation (TAVI) using variable helical pitch scanning and its diagnostic performance for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Shunsuke; Yamada, Yoshitake; Hashimoto, Masahiro; Okamura, Teppei; Jinzaki, Masahiro [Keio University School of Medicine, Department of Diagnostic Radiology, Shinanomachi, Shinjuku-ku, Tokyo (Japan); Yamada, Minoru [Keio University School of Medicine, Research Park, Tokyo (Japan); Yashima, Fumiaki; Hayashida, Kentaro; Fukuda, Keiichi [Keio University School of Medicine, Department of Cardiology, Tokyo (Japan)

    2017-05-15

    To evaluate the effectiveness of CT before TAVI using variable helical pitch (VHP) scanning and its diagnostic performance for coronary artery disease (CAD). Sixty patients (84.4 ± 4.6 years) scheduled for TAVI underwent CT using VHP scanning with the contrast material (CM) volume calculated as scanning time x weight [kg] x 0.06 mL. Retrospective electrocardiography (ECG)-gated scanning was utilized to examine the thorax, and non-ECG-gated scanning of the abdomen immediately followed. We analyzed CT attenuation values of the coronary arteries, aorta, iliac and femoral arteries. The coronary CT angiography images were evaluated for the presence of stenosis (≥50 %); invasive coronary angiography served as a reference standard. The average attenuations of all of the arteries were greater than 400 HU. We could evaluate the peripheral access vessels and dimensions of the ascending aorta, aortic root, and aortic annulus in all patients. The average volume of CM was 38.7 ± 8.5 mL. On per-patient and vessel analysis, CT showed 91.7 % and 89.5 % sensitivity, and 91.3 % and 97.4 % negative predictive value (NPV). CT using VHP scanning with an average CM volume of 38.7 mL is useful before TAVI and had a high sensitivity and NPV in excluding obstructive CAD. (orig.)

  6. The effect of pitch in multislice spiral/helical CT; L'effet du pas dans la tomodensitometrie spiralee/helicoidale multidetecteurs

    Energy Technology Data Exchange (ETDEWEB)

    Wang, G.; Vannier, M.W. [Iowa Univ., Dept. of Radiology, Iowa City, IA (United States)

    2000-07-01

    The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensibility of signal reconstruction from non-uniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensibility of raw data interpolation in multislice spiral CT increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications. (authors)

  7. TH-E-17A-02: High-Pitch and Sparse-View Helical 4D CT Via Iterative Image Reconstruction Method Based On Tensor Framelet

    Energy Technology Data Exchange (ETDEWEB)

    Guo, M [Shanghai JiaoTong University, Shanghai, Shanghai (China); Nam, H [Ewha Womans University, Seoul, Seoul (Korea, Republic of); Li, R [Stanford University, Palo Alto, CA (United States); Xing, L [Stanford University School of Medicine, Stanford, CA (United States); Gao, H [Shanghai Jiao Tong University, Shanghai, Shanghai (China)

    2014-06-15

    Purpose: 4D CT is routinely performed during radiation therapy treatment planning of thoracic and abdominal cancers. Compared with the cine mode, the helical mode is advantageous in temporal resolution. However, a low pitch (∼0.1) for 4D CT imaging is often required instead of the standard pitch (∼1) for static imaging, since standard image reconstruction based on analytic method requires the low-pitch scanning in order to satisfy the data sufficient condition when reconstructing each temporal frame individually. In comparison, the flexible iterative method enables the reconstruction of all temporal frames simultaneously, so that the image similarity among frames can be utilized to possibly perform high-pitch and sparse-view helical 4D CT imaging. The purpose of this work is to investigate such an exciting possibility for faster imaging with lower dose. Methods: A key for highpitch and sparse-view helical 4D CT imaging is the simultaneous reconstruction of all temporal frames using the prior that temporal frames are continuous along the temporal direction. In this work, such a prior is regularized through the sparsity transform based on spatiotemporal tensor framelet (TF) as a multilevel and high-order extension of total variation transform. Moreover, GPU-based fast parallel computing of X-ray transform and its adjoint together with split Bregman method is utilized for solving the 4D image reconstruction problem efficiently and accurately. Results: The simulation studies based on 4D NCAT phantoms were performed with various pitches (i.e., 0.1, 0.2, 0.5, and 1) and sparse views (i.e., 400 views per rotation instead of standard >2000 views per rotation), using 3D iterative individual reconstruction method based on 3D TF and 4D iterative simultaneous reconstruction method based on 4D TF respectively. Conclusion: The proposed TF-based simultaneous 4D image reconstruction method enables high-pitch and sparse-view helical 4D CT with lower dose and faster speed.

  8. Usefulness of the helical CT in gastro intestinally caused acute abdomen; Utilidad de la TC helicoidal en el abdomen agudo de origen gastrointestinal

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, R. A. de la; Martel, J.; Albillos, J. C.; Oliver, J. M.; Lopez, J.; Trapero, M. A. [Fundacion Hospital Alcorcon. Madrid (Spain)

    2000-07-01

    At present, there is a vivid debate on the role of the Helical CT (HCT) in the acute abdomen, principally on the usefulness of the non contrast HCT. We aim to present the most common semiological findings and the differential diagnoses, and to give a short description of the indications and protocols, according to the existing literature and to our experience with HCT during the last three years. We believe that the generalization of the use of HCT in emergencies avoid unnecessary surgery and shorten observation times on many occasions, with clear benefits in the clinical management of the patients. (Author) 30 refs.

  9. Evaluation of dual-phase enhancement helical CT in the diagnosis of hepatic lesions%螺旋CT双期增强扫描对肝脏占位性病变的诊断价值

    Institute of Scientific and Technical Information of China (English)

    阎文颖; 李大庆; 王贵浦; 姜慧杰; 刘昌红

    2001-01-01

    目的探讨螺旋CT双期扫描对肝脏占位性病变的诊断价值.方法对98例肝内占位性病变的病人进行螺旋CT双期增强扫描.结果 98例病人中肝癌48例,肝转移瘤19例,肝血管瘤31例.结论螺旋CT扫描速度快,在动脉期和门静脉期分别完成全肝扫描 ,弥补了一般动态扫描的缺点,对肝内病灶的检出和定性有重要价值.%Objective To evaluate dual-phase helical CT in the diagnosis of hepatic lesions.Methods Dual-phase scanning of the liver in 98 patients with lesio ns was carried out with a helical CT scanner.Results Significant difference was found in dual-phase helical CT about liver lesions.There were 48 hepatic tumor,19 metastases,31 hemangiomas in the remaining 98 patients.Conclusion Helical CT scanning is faster than enventional scanning. The arterial phase and portal venous are performed in all liver.Therefore,it is important to use helical CT detecting characterization of hepatic lesions.

  10. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko [Sumi Hospital, Gifu (Japan); Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu

    1995-04-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author).

  11. Role and pitfalls of hepatic helical multi-phase CT scanning in differential diagnosis of small hemangioma and small hepatocellular carcinoma.

    Science.gov (United States)

    Yan, Fu-Hua; Zeng, Meng-Su; Zhou, Kang-Rong

    1998-08-01

    AIM:To compare and analyze the contrast enhancement appearance of small hemangioma (SHHE) and small hepatocellular carcinoma (SHCC) with helical multi-phase CT scanning so as to determine their roles and pitfalls in the differential diagnosis of SHHE and SHCC.METHODS:The pre and postcontrast CT scanning of the liver in 73 cases (38 SHHE, 35 SHCC) were carried out. The first phase scan of the entire liver began at 30s after the injection of contrast medium, the second and third phases began at 70s, and 4min respectively. The contrast enhancement patterns and characteristics of all lesions were observed and compared.RESULTS In SHHE, 64.29% (27/42) had typical manifestations in two-phase dynamic scanning, such as peripheral dramatic high-density enhancement of the lesions with progressive opacification from the periphery toward the center, 30.95% (13/42) were hyperdense in both phases and 4.76% (2/42) were hypodense in both phases. In the third phase scanning, 96.67% (28/30) of SHHE were hyperdense and isodense.In SHCC 59.52% (25/42) presented typical appearances, such as hyperdense in the first phase and hypodense in the second phase, 23.81% (10/42) were hyperdense in the first phase and isodense in the second phase with 4.76% (2/42) of hypodense in both phases. In the third phase scanning, 85.71% (24/28) of SHCC were hypodense.CONCLUSION:According to the contrast enhancement patterns of SHHE and SHCC in the two-phase or multi-phase scanning by helical CT, diagnosis can be established in the majority of lesions, while some atypical cases needed MRI for further investigation.

  12. Role and pitfalls of hepatic helical multi-phase CT scanning in differential diagnosis of small hemangioma and small hepatocellular carcinoma

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    AIM To compare and analyze the contrast enhancement appearance of small hemangioma (SHHE) and small hepatocellular carcinoma (SHCC) with helical multi-phase CT scanning so as to determine their roles and pitfalls in the differential diagnosis of SHHE and SHCC.METHODS The pre and postcontrast CT scanning of the liver in 73 cases (38 SHHE, 35 SHCC) were carried out. The first phase scan of the entire liver began at 30s after the injection of contrast medium, the second and third phases began at 70s, and 4min respectively. The contrast enhancement patterns and characteristics of all lesions were observed and compared.RESULTS In SHHE, 64.29% (27/42) had typical manifestations in two-phase dynamic scanning, such as peripheral dramatic high-density enhancement of the lesions with progressive opacification from the periphery toward the center, 30.95% (13/42) were hyperdense in both phases and 4.76% (2/42) were hypodense in both phases. In the third phase scanning, 96.67% (28/30) of SHHE were hyperdense and isodense. In SHCC 59.52% (25/42) presented typical appearances, such as hyperdense in the first phase and hypodense in the second phase, 23.81% (10/42) were hyperdense in the first phase and isodense in the second phase with 4.76% (2/42) of hypodense in both phases. In the third phase scanning, 85.71% (24/28) of SHCC were hypodense.CONCLUSION According to the contrast enhancement patterns of SHHE and SHCC in the two-phase or multi-phase scanning by helical CT, diagnosis can be established in the majority of lesions, while some atypical cases needed MRI for further investigation.

  13. Clinical applications for multiplanar- and three-dimensional-reconstructions by helical-CT for the diagnosis of acetabular fractures; Klinischer Einsatz multiplanarer und 3D-Rekonstruktionen der Spiral-CT in der Diagnostik der Azetabulumfrakturen

    Energy Technology Data Exchange (ETDEWEB)

    Stroszczynski, C. [Strahlenklinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany); Stoeckle, U. [Unfallchirurgische Klinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany); Wellmann, A. [Strahlenklinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany); Beier, J. [Deutsches Herzzentrum Berlin, Virchow-Klinikum, Abt. Innere Medizin und Kardiologie (Germany); Wicht, L. [Strahlenklinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany); Hoffmann, R. [Unfallchirurgische Klinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany); Felix, R. [Strahlenklinik und Poliklinik im Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Berlin (Germany)

    1996-03-01

    This review describes recent visualizations of computed tomography for the diagnosis of acetabular fractures. The techniques of conventional and helical-CT for the imaging of the acetabulum are compared. Furthermore, the different methods of multiplaner and three-dimensional reconstructions e.g. shaded surface display, maximum intensity projection, and volume rendering are presented. Figures of multiplanar and three-dimensional imaging for fractures of the pelvis is discussed. (orig.) [Deutsch] Es wird eine Uebersicht moderner computertomographischer Darstellungsmethoden der Azetabulumfrakturen vorgestellt. Auf die einzelnen Charaktersitika der konventionellen und Spiral-CT-Technik wird eingegangen, weiterhin werden die multiplanaren und verschiedenen 3dimensionalen Rekonstruktionsverfahren Shaded-Surface-Display (SSD), Maximum-Intensitaetsprojektion (MIP) und Volume-Rendering (VR) beschrieben und jeweils anhand von Abbildungen erlaeutert. Darueber hinaus wird das diagnostische Potential der einzelnen Methoden diskutiert. (orig.)

  14. Optimal timing by contrast media of deep venous thrombosis. Study of whole body contrast media by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Taniyama, Hidemi; Seto, Kazuto [Kagoshima City Hospital (Japan)

    2002-11-01

    The contrast media of deep veins in the lower extremities reaches there more slowly and is more variable than the arrival time in an artery. Therefore, it was worried about the contrast media by CT of deep venous thrombosis (suspect) due to the injection speed and the setup of delay time. On this occasion, before examining deep venous thrombosis, I refer to the data of CT volume of each department place and the arrival time contrast media by whole body CT and has applied to delay time examination of deep venous thrombosis (suspect). (author)

  15. SU-E-I-15: Quantitative Evaluation of Dose Distributions From Axial, Helical and Cone-Beam CT Imaging by Measurement Using a Two-Dimensional Diode-Array Detector

    Energy Technology Data Exchange (ETDEWEB)

    Chacko, M; Aldoohan, S; Sonnad, J; Ahmad, S; Ali, I [University of Oklahoma Health Science Center, Oklahoma City, OK (United States)

    2015-06-15

    Purpose: To evaluate quantitatively dose distributions from helical, axial and cone-beam CT clinical imaging techniques by measurement using a two-dimensional (2D) diode-array detector. Methods: 2D-dose distributions from selected clinical protocols used for axial, helical and cone-beam CT imaging were measured using a diode-array detector (MapCheck2). The MapCheck2 is composed from solid state diode detectors that are arranged in horizontal and vertical lines with a spacing of 10 mm. A GE-Light-Speed CT-simulator was used to acquire axial and helical CT images and a kV on-board-imager integrated with a Varian TrueBeam-STx machine was used to acquire cone-beam CT (CBCT) images. Results: The dose distributions from axial, helical and cone-beam CT were non-uniform over the region-of-interest with strong spatial and angular dependence. In axial CT, a large dose gradient was measured that decreased from lateral sides to the middle of the phantom due to large superficial dose at the side of the phantom in comparison with larger beam attenuation at the center. The dose decreased at the superior and inferior regions in comparison to the center of the phantom in axial CT. An asymmetry was found between the right-left or superior-inferior sides of the phantom which possibly to angular dependence in the dose distributions. The dose level and distribution varied from one imaging technique into another. For the pelvis technique, axial CT deposited a mean dose of 3.67 cGy, helical CT deposited a mean dose of 1.59 cGy, and CBCT deposited a mean dose of 1.62 cGy. Conclusions: MapCheck2 provides a robust tool to measure directly 2D-dose distributions for CT imaging with high spatial resolution detectors in comparison with ionization chamber that provides a single point measurement or an average dose to the phantom. The dose distributions measured with MapCheck2 consider medium heterogeneity and can represent specific patient dose.

  16. Aortic non communicating dissections. A study with helical CT; Studio dell'ematoma intramurale aortico. Aspetti con Tomografia Computerizzata spirale

    Energy Technology Data Exchange (ETDEWEB)

    Midiri, M.; Strada, A.; Stabile Ianora, A.A.; Rotondo, A.; Angelelli, G. [Bari Univ., Bari (Italy). Dipt. di Medicina Interna e Medicina Pubblica, Sez. di Diagnostica per Immagini; Scialpi, M. [Ospedale SS. Annunziata, Taranto (Italy); D' Agostino, D.; De Luca Tupputi Schinosa, L. [Bari Univ., Bari (Italy). Dipt. Emergenze Trapianto d' Organo, Sez. di Cardiochirurgia

    2000-09-01

    The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low density on enhanced images in all patients. Thickening was eccentric in 14/18 patients and concentric in 4/18 only; it always exceeded 4 mm. It was found some intimal calcifications in 8 patients and hemo thorax and/or hemo mediastinum in 9 patients. A patient with type A hematoma died of cardiac tamponade a few hours after CT diagnosis. Six patients (5 type B and 1 type A) underwent anti-hypertensive treatment and radiological follow-up. Eleven patients (6 type A and 5 type B) underwent prosthesis replacement and 5 of them (3 type A and 2 type B) died of postoperative complications. In the 5 type B patients surgery was performed because of treatment-resistant pain and of the onset of ischemic complications to abdominal organs caused by involvement of the main collateral branches of the aorta. One patient with type A hematoma was submitted to drug treatment because it was judged unresectable. Intramural hematoma of the aorta is a distinct pathological entity, which should not be

  17. Multiple helical scans and the reconstruction of over FOV-sized objects in cone-beam CT

    Institute of Scientific and Technical Information of China (English)

    Han Yu; Yan Bin; Li Lei; Yu Chao-Qun; Li Jian-Xin; Bao Shang-Lian

    2012-01-01

    In cone-beam computed tomography (CBCT),there are often cases where the size of the specimen is larger than the field of view (FOV) (referred to as over FOV-sized (OFS)).To acquire the complete projection data for OFS objects,some scan modes have been developed for long objects and short but over-wide objects.However,these modes still cannot meet the requirements for both longitudinally long and transversely wide objects.In this paper,we propose a multiple helical scan mode and a corresponding reconstruction algorithm for both longitudinally long and transversely wide objects.The simulation results show that our model can deal with the problem and that the results are acceptable,while the OFS object is twice as long compared with the FOV in the same latitude.

  18. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    Directory of Open Access Journals (Sweden)

    Erdi Yusuf E

    2007-03-01

    Full Text Available Abstract Background It is estimated that 60 million computed tomography (CT scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. Methods The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. Results The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Conclusion Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.

  19. Lung cancer screening with low-dose helical CT in Korea: experiences at the Samsung Medical Center.

    Science.gov (United States)

    Chong, Semin; Lee, Kyung Soo; Chung, Myung Jin; Kim, Tae Sung; Kim, Hojoong; Kwon, O Jung; Choi, Yoon-Ho; Rhee, Chong H

    2005-06-01

    To determine overall detection rates of lung cancer by low-dose CT (LDCT) screening and to compare histopathologic and imaging differences of detected cancers between high- and low-risk groups, this study included 6,406 asymptomatic Korean adults with >or=45 yr of age who underwent LDCT for lung cancer screening. All were classified into high- (>or=20 pack-year smoking; 3,353) and low-risk (3,053; <20 pack-yr smoking and non-smokers) groups. We compared CT findings of detected cancers and detection rates between high- and low-risk. At initial CT, 35% (2,255 of 6,406) had at least one or more non-calcified nodule. Lung cancer detection rates were 0.36% (23 of 6,406). Twenty-one non-small cell lung cancers appeared as solid (n=14) or ground-glass opacity (GGO) (n=7) nodules. Cancer likelihood was higher in GGO nodules than in solid nodules (p<0.01). Fifteen of 23 cancers occurred in high-risk group and 8 in low-risk group (p=0.215). Therefore, LDCT screening help detect early stage of lung cancer in asymptomatic Korean population with detection rate of 0.36% on a population basis and may be useful for discovering early lung cancer in low-risk group as well as in high-risk group.

  20. Jejunal GIST causing acute massive gastrointestinal bleeding: role of multidetector row helical CT in the preoperative diagnosis and management.

    Science.gov (United States)

    Daldoul, Sami; Moussi, Amir; Triki, Wissem; Baraket, Rym Bennaceur; Zaouche, Abdeljelil

    2012-09-01

    In this report, we describe a 34-year-old man with a jejunal gastrointestinal stromal tumour (GIST) accompanied by an unusual severe haemorrhage. Because oesophagogastroduodenoscopy proved inconclusive in determining the source of the bleeding and also because of gradually dropping haemoglobin levels and persistence of the melena not allowing colonic preparation, colonoscopy was cancelled and a mesenteric angio-computed tomography (angio-CT) was deemed necessary. The results of this analysis showed a 5-cm heterogeneous mass located in the jejunal loop surrounded by abnormal arterial structures. This multidetector computed tomography (MDCT) appearance was highly suggestive of GIST. The patient then underwent an urgent laparotomy and, peroperative findings being compatible with angio-CT descriptions, a small-bowel resection was performed. The results of the histopathological examination confirmed the diagnosis of GIST. Angio-CT helps define the size of GIST as well as its range and location and can be used as the primary routine test for patients suffering from lower-GI bleeding.

  1. Biphasic Malignant Pleural Mesothelioma Masquerading as a Primary Skeletal Tumor

    Science.gov (United States)

    Diacovo, Maria Julia

    2016-01-01

    Biphasic malignant pleural mesothelioma is a rare malignant tumor, usually presenting as a pleural-based mass in a patient with history of chronic asbestos exposure. We herein report a case of a 41-year-old man who presented with chest pain and had a chest computed tomography (CT) scan suggestive of a primary skeletal tumor originating from the ribs (chondrosarcoma or osteosarcoma), with no history of asbestos exposure. CT-guided core needle biopsies were diagnosed as malignant sarcomatoid mesothelioma. Surgical resection and chest wall reconstruction were performed, confirming the diagnosis and revealing a secondary histologic component (epithelioid), supporting the diagnosis of biphasic malignant mesothelioma. PMID:27660729

  2. Biphasic Malignant Pleural Mesothelioma Masquerading as a Primary Skeletal Tumor

    Directory of Open Access Journals (Sweden)

    James Benjamin Gleason

    2016-01-01

    Full Text Available Biphasic malignant pleural mesothelioma is a rare malignant tumor, usually presenting as a pleural-based mass in a patient with history of chronic asbestos exposure. We herein report a case of a 41-year-old man who presented with chest pain and had a chest computed tomography (CT scan suggestive of a primary skeletal tumor originating from the ribs (chondrosarcoma or osteosarcoma, with no history of asbestos exposure. CT-guided core needle biopsies were diagnosed as malignant sarcomatoid mesothelioma. Surgical resection and chest wall reconstruction were performed, confirming the diagnosis and revealing a secondary histologic component (epithelioid, supporting the diagnosis of biphasic malignant mesothelioma.

  3. Hepatic and vascular enhancement at dual-phase helical CT: comparison of Iobitridol 300 and Iohexol 300 in a prospective randomized study

    Energy Technology Data Exchange (ETDEWEB)

    Legmann, P.; Vignaux, O.; Bahurel, H.; Oudjit, A. [Dept. of Radiology, Universite Rene Descartes, Paris (France); Coste, J. [Dept. of Biostatistics and Epidemiology, Universite Rene Descartes, Paris (France)

    2001-11-01

    The purpose of this study was to determine hepatic and vascular enhancement, clinical tolerance, and iconographic quality of Iobitridol (300 mg/ml) at dual-phase helical CT and to compare it with Iohexol (300 mg/ml). One hundred forty-six patients were randomly divided into two groups. Each group received 120 ml of Iohexol (group A) or Iobitridol (group B). Mean enhancement of liver, aorta and portal vein was obtained at the arterial phase and at the portal-venous phase. Overall image quality was assessed by two independent blinded investigators. Adverse reactions were recorded. There were no significant differences in demographic characteristics and distribution of patient intrinsic parameters between the two groups, except for blood pressure but without statistical correlation between the difference in blood pressure and the impact on enhancement measurements. There was no significant difference in clinical tolerance and image quality. Mean liver as well as aortic and portal vein enhancement measurements did not show any significant difference. Iobitridol compares favorably with Iohexol. Both products have similar safety, tolerance, and efficacy. Both contrast media have equivalent blood pool concentration and interstitial compartment diffusion. (orig.)

  4. Low-dose ECG-gated 64-slices helical CT angiography of the chest: evaluation of image quality in 105 patients

    Energy Technology Data Exchange (ETDEWEB)

    D' Agostino, A.G.; Remy-Jardin, M.; Khalil, C.; Remy, J. [University Center of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Delannoy-Deken, V.; Duhamel, A. [University of Lille, Department of Medical Statistics, Lille (France); Flohr, T. [Siemens Medical, Research and Development Department, CT Division, Forchheim (Germany)

    2006-10-15

    The purpose of this study was to evaluate image quality of low-dose electrocardiogram (ECG)-gated multislice helical computed tomography (CT) angiograms of the chest. One hundred and five consecutive patients with a regular sinus rhythm (72 men; 33 women) underwent ECG-gated CT angiographic examination of the chest without administration of beta blockers using the following parameters: (a) collimation 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices, rotation time 0.33 s, pitch 0.3; (b) 120 kV, 200 mAs; (c) use of two dose modulation systems, including adjustment of the mAs setting to the patient's size and anatomical shape and an ECG-controlled tube current. Subjective and objective image quality was evaluated by two radiologists in consensus on 3-mm-thick scans reconstructed at 55% of the response rate (RR) interval. The population and protocol characteristics included: (a) a mean [{+-}standard deviation (SD)] body mass index (BMI) of 24.47 ({+-}4.64); (b) a mean ({+-}SD) heart rate of 72.04 ({+-}15.76) bpm; (c) a mean ({+-}SD) scanning time of 18.3 ({+-}2.73) s; (d) a mean ({+-}SD) dose-length product (DLP) value of 260.57 ({+-}83.67) mGy/cm; (e) an estimated average effective dose of 4.95 ({+-}1.59) mSv. Subjective noise was depicted in a total of nine examinations (8.5%), always rated as mild. Objective noise was assessed by measuring the standard deviation of pixel values in a homogeneous region of interest within the trachea and descending aorta; SD was 15.91 HU in the trachea and 22.16 HU in the descending aorta, with no significant difference in the mean value of the standard deviations between the four categories of BMI except for obese patients, who had a higher mean SD within the aorta. Interpolation artefacts were depicted in 22 patients, with a mean heart rate significantly lower than that of patients without interpolation artifacts, rated as mild in 11 patients and severe in 11 patients. The severity of

  5. Helicity scalings

    Energy Technology Data Exchange (ETDEWEB)

    Plunian, F [ISTerre, CNRS, Universite Joseph Fourier, Grenoble (France); Lessinnes, T; Carati, D [Physique Statistique et Plasmas, Universite Libre de Bruxelles (Belgium); Stepanov, R, E-mail: Franck.Plunian@ujf-grenoble.fr [Institute of Continuous Media Mechanics of the Russian Academy of Science, Perm (Russian Federation)

    2011-12-22

    Using a helical shell model of turbulence, Chen et al. (2003) showed that both helicity and energy dissipate at the Kolmogorov scale, independently from any helicity input. This is in contradiction with a previous paper by Ditlevsen and Giuliani (2001) in which, using a GOY shell model of turbulence, they found that helicity dissipates at a scale larger than the Kolmogorov scale, and does depend on the helicity input. In a recent paper by Lessinnes et al. (2011), we showed that this discrepancy is due to the fact that in the GOY shell model only one helical mode (+ or -) is present at each scale instead of both modes in the helical shell model. Then, using the GOY model, the near cancellation of the helicity flux between the + and - modes cannot occur at small scales, as it should be in true turbulence. We review the main results with a focus on the numerical procedure needed to obtain accurate statistics.

  6. 扫描方式对64层螺旋CT头颅 CTA图像质量和辐射剂量影响的研究%Comparison study of image quality and radiation dose between helical and axial CT angiography of the head with 64-slice helical CT

    Institute of Scientific and Technical Information of China (English)

    戴贵东; 肖正远; 兰永树; 粱卡丽

    2012-01-01

    目的:探讨64层螺旋CT扫描方式对头颅CTA图像质量和辐射剂量的影响.方法:采用GE Lightspeed VCT 对100例需要行头颅CTA检查的患者进行对比研究,50例行螺旋扫描,另50例行轴层扫描.两组数据经过VR、MIP、去骨VR和多平面重组等方法后处理,然后由3组医师通过5分评价法对CTA图像质量进行主观评价,取其均值纳入统计学分析;记录每组扫描的容积剂量指数(CTDIvol)和剂量长度乘积(DLP).对两组数据进行两独立样本t检验.结果:轴向扫描图像质量评分是(4.66±0.42)分、螺旋扫描CTA的成像质量评分(4.67±0.38)分;两组数据差异无统计学意义(P>0.05).轴向扫描、螺旋扫描的CTDIvol分别是45.71和54.18mGy; DLP分别是731.43和954.68mGy·cm.两组间差异有统计学意义(P<0.05),轴层扫描方式辐射剂量更低.结论:64层CT头颅CTA轴扫可以显著降低辐射剂量而不降低图像质量,在临床运用中值得关注.%Objective: To compare the difference in image quality and radiation dose between helical and axial CT angiography of the head with 64 slices helical CT. Methods:100 patients with suspected or confirmed cerebrovascular disease in our hospital,were divided into two groups to accept CTA examination :helical scanning group (50 cases) and axial scan ning group (50 cases). Except the parameter of scanning method,each group was examined with the same scan parameters and equipment. 80ml contrast medium was injected (via a cubital vein) by 4. 3ml/s and followed by 35ml normal sodium at the same speed. The cerebral vessels were imaged by these postprocessing methods: maximum intensity projection (MIP) volume rendering (VR) ,and "Auto Select" technique. Three group of doctors evaluated the image quality by means of 5 point scoring subjective evaluation. The radiation dose report was auto generated, trie average value ol volume CT dose index (CTDIvol) and dose length product (DLP) were taken into the sheet. All the data

  7. Common breakdown maintenance of GE light speed 16-slice Helical CT%GE light speed 16排螺旋CT常见故障的维修和体会

    Institute of Scientific and Technical Information of China (English)

    苏根元; 王萍萍; 于小晶

    2011-01-01

    Recently,with the extensive application of multi-slice Helical CT,all sorts of failure have been encountered in practice.On the basis of mastering basic principal and structure of multi-slice Helical CT,and relevant knowledge of computer,many breakdowns may be quickly resolved.It has greatly improved the efficiency of equipments and ensured daily operations.This paper briefly describes common breakdown of GE light speed 16-slice Helical CT in our hospital,and summarizes diagnostic analysis,solution and experience.It can serve as reference for concerned personnel.%多排螺旋CT目前已广泛应用于临床,使用过程中会遇到各种各样故障,在熟练掌握多排螺旋CT的基本原理,工作结构,及相关计算机知识的基础上,可以对多排螺旋CT机很多常见故障进行快速及时修复,大大提高了设备使用率,保证临床工作的顺利进行。本文简要阐述了我院GE light speed 16排螺旋CT在使用过程中常见的故障现象、诊断分析、解决方法和体会。为相关专业技术人员提供一定的参考和借鉴。

  8. MSCT在无典型临床表现阑尾炎诊断中的应用%Helical CT scanning in the diagnosis of acute appendicitis without typica clinical features

    Institute of Scientific and Technical Information of China (English)

    吴丽卓; 王景宇; 王淑清

    2011-01-01

    Objective To investigate the value of helical CT in diagnosis of appendicitis with atypical clinical feature .MethodsHelical CT manifestations of 64 cases of appendicitis which were not initially considered on clinical presentation confirmed surgically and pathologically were retrospectively analyze .Results Helical CT findings of appendicitis included ;23cases of dissect abnormal ap-pendicitis (36.0 %)(7cases of pelvic appendicitis ,10cases of retro-peritoneal appendicitis ,6cases of superior position appendicitis ) ; 15cases of the infant acute appendicitis (23.0 % ) ; 26cases of the senior citizen acute appendicitis (41.0% ) .Conclusion MSCT has important significance to the diagnosis and the differential diagnosis of appendicitis and its complications atipica appendicitis .%目的 探讨MSCT扫描在临床表现不典型阑尾炎诊断中的价值.方法 回顾性分析64例特殊类型阑尾炎的临床表现、CT扫描特征和手术资料.结果 64例经手术、病理证实的急性阑尾炎中,CT诊断与手术相符者57例,诊断符合率89.0%.CT扫描诊断为解剖异常阑尾23例(36.0%)(盆腔阑尾7例,腹膜后位阑尾10例,肝下阑尾6例);小儿急性阑尾炎15例(23.0%);老年人急性阑尾炎26例(41.0%).结论 MSCT扫描对临床表现不典型阑尾炎的诊断,具有较高的临床价值.

  9. Ureterolithiasis: classical and atypical findings on unenhanced helical computed tomography.

    Science.gov (United States)

    Vaswani, Kuldeep K; El-Dieb, Adam; Vitellas, Kenneth M; Bennett, William F; Bova, James G

    2002-03-01

    Evaluation of patients with acute flank pain using helical computed tomography (CT) is a well-accepted, rapid, and safe procedure in the emergency setting. Various primary and secondary signs are described in the literature for evaluation of these patients. Our purpose is to demonstrate both the classical findings associated with ureteral calculi on unenhanced helical CT and atypical findings and potential pitfalls. We also provide readers with a systematic approach to interpreting unenhanced helical CT scans performed for acute flank pain.

  10. Contrast-enhanced helical CT in sigmoid diverticulitis. Findings and impact on diagnosis and treatment; Ruolo della tomografia computerizzata spirale nella diverticolite del sigma e implicazioni diagnostico-terapeutiche

    Energy Technology Data Exchange (ETDEWEB)

    Scaglione, M.; Romano, L.; Pinto, A.; De Lutio di Castelguidone, E.; Giovine, S.; Pinto, F. [Azienda Ospedaliera di Rilievo Nazionale A. Cardarelli, Naples (Italy). Dipt. di Diagnostica per Immagini; Forner, A.L. [Azienda Ospedaliera di Rilievo Nazionale A. Cardarelli, Naples (Italy). Dipt. di Chirurgia d' Urgenza; Grassi, R. [Naples Univ. II, Naples (Italy). Ist. di Radiologia

    2000-03-01

    Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e dal confronto dei reperti TC con i riscontri clinici e chirurgici. Sono analizzati e discussi i risultati dello studio di 41 pazienti consecutivi con diverticolite del sigma esaminati dal giugno del 1998 al giugno del 1999. La TC spirale ha fornito dettagli precisi sul danno anatomo-chirurgico dell'ansa e sulle strutture limitrofe coinvolte consentendo di differenziare la diverticolite lieve da quella grave. Il suo ruolo si configura nei pazienti critici difficilmente classificabili e nelle sospette diverticoliti gravi o complicate per la molteplicita' delle scelte terapeutiche.

  11. Percutaneous radiofrequency thermal ablation of lung VX2 tumors in a rabbit model: evaluation with helical CT findings for the complete and partal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Gong Yong; Han, Young Min; Lim, Yeong Su; Jang, Kyu Yun; Lee, Sang Yong; Chung, Gyung Ho [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2004-05-01

    To evaluate the radiologic findings for complete and partial ablation after percutaneous CT-guided transthoracic radiofrequency ablation (RFA) of lung VX2 tumor implanted in rabbits. Thirteen rabbits with successfully implanted lung VX2 were used. Three rabbits as controls did not receive RFA while the other ten rabbits underwent RFA; 5 complete and 5 partial. RFA was performed using an internally cooled, 17-gauge electrode (Radionics, Burlington, MA) with a 1-cm active tip under CT guidance. Postprocedural CT was performed within 3 days, and we analyzed the ablated size, enhancement pattern, shape, margin, and complications of the complete and partial ablation groups. Rabbits were sacrificed after postprocedural CT with an overdose of ketamine, and pathologic findings of the ablated groups were compared with those of the control group. The size of the ablated lesions and the enhancement pattern differed between the completely and partially ablated groups on chest CT. The size of the ablated lesions was increased by 47.1% in the completely ablated group and by 2.1% in the partially ablated group. In the completely ablated group, VX2 tumor showed absolutely no enhancement, whereas only ablated pulmonary parenchyma outside VX2 showed mild enhancement on enhanced CT. In the partial ablated group, a part of VX2 became strongly enhanced on enhanced CT. On microscopic examination, the completely ablated group demonstrated that a viable tumor cell was not visible. In the partially ablated group, however, a viable tumor cell within the surrounding fibrous capsule on the peripheral area of the VX2 was observed. The important CT findings for evaluation of complete and partial RFA are the ablated size and enhancement pattern of the ablated lesion.

  12. 螺旋CT与肺功能测定在特发性肺纤维化中的相关性研究%Correlation between Helical CT Findings and Pulmonary Function Test Results in Idiopathic Pulmonary Fibros

    Institute of Scientific and Technical Information of China (English)

    王建民

    2011-01-01

    目的:探讨特发性肺纤维化(IPF)患者的螺旋CT与肺功能的相关性.方法:对45例IPF患者的螺旋CT征象和肺功能检查结果进行分析.其中17例对兴趣区追加高分辨率CT扫描.所有病例均CT检查前后5d内行肺功能检查.观察IPF患者肺功能损害程度和CT征象及其解剖分布,评价CT征象与肺功能损害的关系.结果:45例IPF均有不同程度的限制性通气功能障碍.肺功能轻度受损8例,均有磨玻璃样密度影;中度受损12例,均有网格影和小叶间隔增厚.重度受损25例.均有蜂窝肺,其中7例表现有牵拉性支气管扩张.肺功能重度受损的患者有阻塞性合并限制性通气功能障碍.结论:螺旋CT能准确反应IPF的病理变化,IPF不同程度的肺功能受损与螺旋CT征象存在相关性.两者相结合有助于IPF的诊断和预测IPF的进展.预后以及治疗效果.%Objective:To determine the correlation between helical CT findings and pulmonary function test(PFT) results from patients with idiopathic pulmonary fibrosis( IPF). Methods:Helical CT scan was performed in 45 cases idiopathic pulmonary fibrosis. Pulmonary function test foreach patient was performed with in 5 days before or after CT scan.The correlation between CT findings and pulmonary function test results was assessed.Results:Pulmonary function test revealed characteristic restrictive ventilatory defect with reduction of total lung capacity, residual volume, vital capacity, and diffusing capacity of the for carbon monoxide.The patients with different severities of pulmonary function impairment had different CT features. 8 cases with slight impairment of the pulmonary function had the ground -glass opacity, 12 cases with moderate impairment showed the reticular pattern and the thickened interlobar septa, 25 cases with severe impairment showe dthe honeycombing,and 7 of 25 cases with severe impairment showed the traction bronchiectasis. Conclusion:There is a good correlation between PFT

  13. Helical filaments

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Nicholas; Lim, Khan; Durand, Magali; Baudelet, Matthieu; Richardson, Martin [Townes Laser Institute, CREOL—The College of Optics and Photonics, University of Central Florida, Orlando, Florida 32816 (United States); Hosseinimakarem, Zahra; Johnson, Eric [Micro-Photonics Laboratory – Center for Optical Material Science, Clemson, Anderson, South Carolina 29634 (United States)

    2014-06-30

    The shaping of laser-induced filamenting plasma channels into helical structures by guiding the process with a non-diffracting beam is demonstrated. This was achieved using a Bessel beam superposition to control the phase of an ultrafast laser beam possessing intensities sufficient to induce Kerr effect driven non-linear self-focusing. Several experimental methods were used to characterize the resulting beams and confirm the observed structures are laser air filaments.

  14. Image quality and feasibility of an ultralow-dose high-pitch helical triple-rule-out computed tomography angiography acquired in the caudocranial direction.

    Science.gov (United States)

    Kligerman, Seth J; White, Charles S

    2014-01-01

    The aim of this study was to assess the feasibility and image quality of a low-dose triple-rule-out (TRO) computed tomography (CT) angiogram on a second-generation dual-source CT scanner using a high-pitch helical acquisition. Ten men (mean age 56.3 y, average body mass index 24.2) underwent TRO CT angiography using a high-pitch helical acquisition. Patients were imaged from the lung bases to the thoracic inlet in a caudocranial direction. A biphasic injection was administered at 6 mL/s. Study parameters including kVp, mAs, CT dose index volume, dose-length product, and effective dose were calculated. Image quality was independently assessed by 2 cardiothoracic radiologists using the following scale: 1-nondiagnostic; 2-moderately limited diagnostic ability; 3-mild limitation but diagnostic; 4-ideal. For each patient up to 23 structures were evaluated: 17 coronary segments, 3 pulmonary artery levels, 2 aortic sections, and the lung parenchyma. The unpaired t test and the Fisher exact test were used for comparison between patients scored at 80 and 100 kV. The average CT dose index volume, dose-length product, and effective dose for the TRO scans was 2.65, 81.9, and 1.39 mSv, respectively. Readers 1 and 2 scored 171/203 (83%) and 173/203 (84%) of the evaluated regions as ideal and 26/203 (12.8%) and 24/203 (11.8%) as being mildly limited, respectively. Each reader graded 6/203 (3.9%) as being moderately limited. No areas were nondiagnostic. Patients scanned at 80 kV had a significantly higher number of limited segments for readers 1 (P=0.0012) and 2 (P=0.0027). Low-dose, high-image quality TRO scans can be effectively performed using a high-pitch helical acquisition.

  15. Comparison between helical computed tomography angiography and intraoperative findings

    Directory of Open Access Journals (Sweden)

    Abijit Shetty

    2014-01-01

    Conclusions: Helical CT is important in delineating the arterial, venous, and ureteral anatomy and can show the important incidental findings. Left renal donors and males have more variations in their renal anatomy. Technically challenging laparoscopic nephrectomy on the multiple-vessel-side donor is possible with the aid of helical CT. The importance of the CT in evaluating donor renal anatomy for a technically challenging laparoscopic donor nephrectomy is commendable.

  16. CT of tracheal agenesis

    Energy Technology Data Exchange (ETDEWEB)

    Strouse, Peter J.; Hernandez, Ramiro J. [C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Newman, Beverley [Children' s Hospital of Pittsburgh, PA (United States). Department of Pediatric Radiology; Afshani, Ehsan [Children' s Hospital of Buffalo, NY (United States). Departments of Radiology and Pediatrics; Bommaraju, Mahesh [Women' s and Children' s Hospital of Buffalo, Division of Neonatology, University Pediatrics Associates, Buffalo, NY (United States)

    2006-09-15

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  17. Measurement of MV CT dose index for Hi-ART helical tomotherapy unit%Hi-ART螺旋断层放疗机MV螺旋CT剂量指数的测量

    Institute of Scientific and Technical Information of China (English)

    王运来; 廖雄飞

    2010-01-01

    目的 探讨Hi-ART螺旋断层放疗机MV扇形束CT图像获取过程中患者接受的剂量.方法 用PTW TM30009 CT电离室分别在T40017头部和T40016躯干模体中,选择扫描层厚2、4及6 mm和改变扫描范围等参数,分别测量加权CT剂量指数,计算相应的剂量长度乘积,并与XVIkV锥形束CT、ACQSim模拟定位CT的结果进行比较.结果 Hi-ART螺旋断层治疗机的CT剂量指数与层厚成反比,剂量长度乘积与扫描范围成正比.临床应用条件下Hi-ART的CT剂量指数在头颈部比XVI kV锥形束CT大,但躯干较小.结论 CT剂量指数能反映患者成像过程中接受的剂量,可以作为治疗保证与控制的指标.图像引导过程中应该合理选择层厚,减少扫描范围,最大限度减少患者接受剂量.%Objective To evaluate the patient dose from Hi-ART MV helical CT imaging in image-guided radiotherapy.Methods Weighted CT dose index (CTDI_W) was measured with PTW TM30009 CT ion chamber in head and body phantoms,respectively,for slice thicknesses of 2,4,6 mm with scanned range of 5 cm and 15 cm.Dose length products (DLP) were subsequently calculated.The CTDI_W and DLP were compared with XVI kV CBCT and ACQSim simulator CT for routine clinical protocols.Results An inverse relationship between CTDI and the slice thickness was found.The dose distribution was inhomogeneous owing to the attenuation of the couch.CTDI and DLP had close relationship with the slice thickness and the scanned range.Patient dose from MVCT was lower than XVI CBCT for head,but larger for body scan.Results CTDI_W can be used to assess the patient dose in MV helical CT due to its simplicity for measurement and reproducibility.Regular measurement should be performed in QA & QC program.Appropriate slice thickness and scan range should be chosen to reduce the patient dose.

  18. Diagnosis of acute flank pain caused by ureteral stones: value of combined direct and indirect signs on IVU and unenhanced helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Li-Jen; Wong, Yon-Cheong [Department of Diagnostic Radiology, Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing St., Gueishan, 33333, Taipei (Taiwan); Ng, Chip-Jin; Chen, Jih-Chang; Chiu, Te-Fa [Department of Emergency Medicine, Chang Gung Memorial Hospital, Chang Gung University, 5, Fu-Hsing St., Gueishan, 33333, Taipei (Taiwan)

    2004-09-01

    The aim of this study was to assess the usefulness of combined direct and indirect signs on intravenous urography (IVU) and unenhanced helical computed tomography (UHCT) for the diagnosis of ureteral stones in emergency patients with acute flank pain. During an 8-month period, 82 emergency patients with acute flank pain undergoing IVU and UHCT with sufficient clinical follow-up formed the study group. The presence or absence of direct sign (visualization of ureteral stones) and indirect signs on IVU and UHCT was recorded. The diagnostic accuracy of each direct/indirect sign and their combination for the diagnosis of ureteral stones on IVU and UHCT were analyzed and compared. Of the 82 patients, 66 had ureteral stones, four had passed urinary stones prior to imaging and 12 had other diseases. The diagnostic accuracies of direct signs on IVU and UHCT for the diagnosis of ureteral stones were 79.3 and 98.8%, respectively, which was more accurate than that of any single indirect sign on IVU and UHCT. However, the diagnostic accuracy of ureteral stones by IVU increased to 90.2% when using diagnostic criteria requiring the presence of a direct sign or at least three indirect signs, and by UHCT, it increased to 100% when using diagnostic criteria requiring the presence of a direct sign with at least one indirect sign. Therefore, for emergency patients with acute flank pain, the use of the above combinations of direct/indirect signs is useful as the diagnostic criterion for ureteral stones. (orig.)

  19. Efficacy of cholangiography under helical computed tomography for laparoscopic cholecystectomy

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Motoya; Hishiyama, Houhei [Asahikawa Red Cross Hospital, Hokkaido (Japan); Kondo, Satoshi; Katoh, Hiroyuki [Hokkaido Univ., Sapporo (Japan). Graduate School of Medicine

    2002-05-01

    Although laparoscopic cholecystectomy (LC) is known to be safe, the optimal imaging technique for examining the common bile duct and cystic duct prior to laparoscopic intervention remains controversial. The objective of this study was to evaluate the efficacy of cholangiography under helical computed tomography (helical CT cholangiography) for LC. We studied 53 consecutive patients who underwent LC carried out by the same surgeon. The data of 23 of these patients who had undergone LC before the introduction of helical CT were used as the reference standard. Among the 53 patients, 28 were prospectively randomized for preoperative biliary tract evaluation with versus without helical CT cholangiography, into a CT/+ group (n=13) and a CT/- group (n=15), respectively. Two patients were excluded from the study preoperatively. There were no significant differences in age or laboratory findings, including liver function tests or the serum amylase level before or after surgery, between the two groups. In the CT/- group, endoscopic retrograde cholangiography-related pancreatitis developed in one patient, and one patient required conversion to open surgery. In contrast, in the CT/+ group, there were no preoperative complications and no patient required conversion to open surgery. The mean operative time was significantly shorter in the CT/+ group than in the CT/- group (P=0.0137). These findings provide evidence to support the advantages of helical CT cholangiography in relation to operative time, conversion, and procedure-related preoperative complications. (author)

  20. [Minimum intensity projection image and curved reformation image of the main pancreatic duct obtained by helical CT in patients with main pancreatic duct dilation].

    Science.gov (United States)

    Takeshita, K; Furui, S; Yamauchi, T; Harasawa, A; Kohtake, H; Sasaki, Y; Suzuki, S; Tanaka, H; Takeshita, T

    1999-03-01

    Contrast enhanced CT was performed in seven patients with pancreatic disease (chronic pancreatitis, n = 3; pancreatic head cancer, n = 2; mucin-producing pancreatic tumor, n = 2) who showed dilation of the main pancreatic duct (MPD) Minimum intensity projection (Min-IP) images of the pancreas were obtained using multi-projection volume reconstruction (MPVR) software by selecting an oblique slab that contained the entire MPD. Curved reformation (CR) images were obtained using multiplanar reformation (MPR) software by tracing the MPD on the Min-IP image. Both Min-IP images and CR images clearly showed the dilated main pancreatic duct in all seven patients. In three of the seven, obstruction of the MPD in the pancreatic head and the cause of obstruction (tumor mass, n = 2; caliculus, n = 1) were also clearly seen. Min-IP and CR images seem to be useful for the diagnosis of pancreatic diseases.

  1. The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers; Tomografia Computerizzata spirale con elaborazioni tridimensionali di superficie nel trattamento ricostruttivo dei tumori maligni del massiccio facciale

    Energy Technology Data Exchange (ETDEWEB)

    De Rosa, V.; Ziviello, M. [Ospedale Cardarelli, Servizio di Radiodiagnostica, Naples (Italy); Ionna, F.; Mozzillo, N. [Ospedale Cardarelli, Div. di Chirurgia B, Ist. Nazionale Tumori Fondazione G. Pascale, Naples (Italy); Parascandolo, S. [Ospedale Cardarelli, Div. di Chirurgia Maxillo-Facciale, Naples (Italy)

    2000-12-01

    Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micronets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months postoperatively in all patients. The images were generated on a computer workstation using the shaded surface display (SSD) software with threshold values ranging 425 to 630 HU, and a more closed window for the imaging of titanium mesh/bone interface in the post surgical follow-up. It was obtained an excellent complete spatial depiction of maxillo facial region both before and after surgery, with no artefacts so important as to affect the 3D reconstruction process and the image quality. Together with the head-neck surgical team it could be worked for preoperative planning through CT scans by different 3D points of view. The 3D reconstructed follow-up scans showed good filling of the defect in the area where the titanium mesh had been used. Then efficacious bone modelling and good biocompatibility of the alloplastic material were seen in all patients, with no inflammatory reactions. Titanium is a well-known material, which is widely used for cranioplasty. It is a radiolucent, non

  2. Helical localized wave solutions of the scalar wave equation.

    Science.gov (United States)

    Overfelt, P L

    2001-08-01

    A right-handed helical nonorthogonal coordinate system is used to determine helical localized wave solutions of the homogeneous scalar wave equation. Introducing the characteristic variables in the helical system, i.e., u = zeta - ct and v = zeta + ct, where zeta is the coordinate along the helical axis, we can use the bidirectional traveling plane wave representation and obtain sets of elementary bidirectional helical solutions to the wave equation. Not only are these sets bidirectional, i.e., based on a product of plane waves, but they may also be broken up into right-handed and left-handed solutions. The elementary helical solutions may in turn be used to create general superpositions, both Fourier and bidirectional, from which new solutions to the wave equation may be synthesized. These new solutions, based on the helical bidirectional superposition, are members of the class of localized waves. Examples of these new solutions are a helical fundamental Gaussian focus wave mode, a helical Bessel-Gauss pulse, and a helical acoustic directed energy pulse train. Some of these solutions have the interesting feature that their shape and localization properties depend not only on the wave number governing propagation along the longitudinal axis but also on the normalized helical pitch.

  3. Venous thromboembolic disease. CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, L. R. [Medical College of Wisconsin, Pulmonary Medicine and Intensive Care, Dept. of Diagnostic Radiology, Milwaukee, WI (United States)

    2001-12-01

    Helical and multidetector CT has proven to be a valuable imaging modality for both pulmonary embolism and deep venous thrombosis. This paper will review the sensitivity and specificity of CT and discuss diagnostic algorithms utilizing CT and more established imaging technologies.

  4. Value of multi-slice helical CT for diagnosing colonic diverticulitis%多层螺旋CT在结肠憩室炎诊断中的价值

    Institute of Scientific and Technical Information of China (English)

    万荣超; 邓德茂; 袁文昭; 陈文福; 李敏; 廖海; 陈加军

    2014-01-01

    Objective To determine the multi-slice spiral computed tomography(MSCT)features of colonic diverticulitis. Methods The clinical information and MSCT of 11 patients with pathologically confirmed colonic diverticulitis were retrospectively analyzed.Results CT showed colonic diverticula with surrounding fat stranding(10)and fecalith in the diverticula(7),pericolonic fat stranding and pneumoperitoneum(1),colon wall thickening(9),bowel perforation(5)with pneumoperitoneum(3)and hematoma(1). Conclusion MSCT displays clearly the pathological changes and complications of colonic diverticulitis.%目的:分析结肠憩室炎MSCT表现,以提高对该病的认识和诊断水平。方法回顾性分析11例经结肠镜检或手术病理证实结肠憩室炎病例的临床及MSCT资料,并结合文献复习。所有病例均作腹盆部CT平扫检查,其中2例加作CT增强检查,总结结肠憩室炎的MSCT表现特征。结果 CT表现为结肠肠壁囊袋状突出并周围脂肪密度增高10例,其中憩室内粪石7例,仅表现为肠壁周围脂肪密度增高及气腹征者1例,结肠肠壁增厚9例,憩室炎穿孔5例,其中气腹3例,合并出血1例。结论 MSCT能较好的显示结肠憩室炎病变及其并发症,对结肠憩室炎有较高的诊断价值。

  5. The value of MPR and VRT reconstruction with helical CT enhanced images in the diagnosis and pre-operative evaluation of hypopharyneal carcinoma%MSCT增强扫描MPR和VR重建对下咽癌评估的价值

    Institute of Scientific and Technical Information of China (English)

    曹汉海; 孙敬武; 别远志

    2013-01-01

    were diagnosed as piriform fossa cancer,4 were post-cricoid region cancer,and 3 were posterior hypopharyngeal wall cancer.The diagnostic accuracy of helical CT plain scan,axial view CT enhancement scanning,and MPR and VRT images post-processing technique were 94.4% and 98% respectively in the pre-operative diagnosis of focus and neck lymph node metastasis.It was suggested that enhanced images could more clearly show the tumor focus and the invasive extent of the lesion.Especially,venous-phase coronal plane MPR images could demonstrate neck lymph node metastsis much more clearly than that of axial view images.Conclusion Helical CT axial view images combining with MPR and VRT postprocessing technique can clearty demonstrate the focus of hypopharyngeal carcinoma,invasive extension of tumor and metastatic neck lymph nodes.Furthermore,the serverity of narrow in air passage can be directly shown as well.This will be very helpful for making the operating plan preoperatively.

  6. Acute Biphasic Effects of Ayahuasca.

    Directory of Open Access Journals (Sweden)

    Eduardo Ekman Schenberg

    Full Text Available Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8-13 Hz after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30-50 and 50-100 Hz, respectively between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca's chemical compounds, mostly N,N-dimethyltryptamine (DMT, harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered.

  7. Acute Biphasic Effects of Ayahuasca

    Science.gov (United States)

    Schenberg, Eduardo Ekman; Alexandre, João Felipe Morel; Filev, Renato; Cravo, Andre Mascioli; Sato, João Ricardo; Muthukumaraswamy, Suresh D.; Yonamine, Maurício; Waguespack, Marian; Lomnicka, Izabela; Barker, Steven A.; da Silveira, Dartiu Xavier

    2015-01-01

    Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG) recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8–13 Hz) after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30–50 and 50–100 Hz, respectively) between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca’s chemical compounds, mostly N,N-dimethyltryptamine (DMT), harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered. PMID:26421727

  8. Acute Biphasic Effects of Ayahuasca.

    Science.gov (United States)

    Schenberg, Eduardo Ekman; Alexandre, João Felipe Morel; Filev, Renato; Cravo, Andre Mascioli; Sato, João Ricardo; Muthukumaraswamy, Suresh D; Yonamine, Maurício; Waguespack, Marian; Lomnicka, Izabela; Barker, Steven A; da Silveira, Dartiu Xavier

    2015-01-01

    Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG) recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8-13 Hz) after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30-50 and 50-100 Hz, respectively) between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca's chemical compounds, mostly N,N-dimethyltryptamine (DMT), harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered.

  9. Currents for Arbitrary Helicity

    CERN Document Server

    Dragon, Norbert

    2016-01-01

    Using Mackey's classification of unitary representations of the Poincar\\'e group on massles states of arbitrary helicity we disprove the claim that states with helicity |h|>=1 cannot couple to a conserved current by constructing such a current.

  10. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs; Telangiectasia emorragica ereditaria: TC multidetettore multifasica e programmi di ricostruzione nello studio delle alterazioni vascolari epatiche

    Energy Technology Data Exchange (ETDEWEB)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe [Policlinico Universitario, Bari (Italy). DiMIMP Sezione di Diagnostica per Immagini; Suppressa, Patrizia; Cirulli, Anna; Sabba' , Carlo [Policlinico Universitario, Bari (Italy). Centro Interdipartimentale per lo studio dell' HHT

    2005-02-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT. [Italian] Scopo: Valutare le alterazioni epatiche nei pazienti affetti da Telangiectasia Emorraica Ereditaria (TEE) utilizzando una TC multidetettore (TCMD) ed in nuovi programmi di ricostruzione. Materiale e metodi: E' stato eseguito uno

  11. Shearing Wind Helicity and Thermal Wind Helicity

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Helicity is defined as H=V.ω, where V and ω are the velocity and vorticity vectors, respectively.Many works have pointed out that the larger the helicity is, the longer the life cycle of the weather system is. However, the direct relationship of the helicity to the evolution of the weather system is not quite clear. In this paper, the concept of helicity is generalized as shearing wind helicity (SWH). Dynamically,it is found that the average SWH is directly related to the increase of the average cyclonic rotation of the weather system. Physically, it is also pointed out that the SWH, as a matter of fact, is the sum of the torsion terms and the divergence term in the vorticity equation. Thermal wind helicity (TWH), as a derivative of SWH, is also discussed here because it links the temperature field and the vertical wind field. These two quantities may be effective for diagnosing a weather system. This paper applies these two quantities in cylindrical coordinates to study the development of Hurricane Andrew to validate their practical use. Through analyzing the hurricane, it is found that TWH can well describe the characteristics of the hurricane such as the strong convection and release of latent heat. SWH is not only a good quantity for diagnosing the weather system, but also an effective one for diagnosing the development of the hurricane.

  12. Study of optimize scanning program of double helical CT in reducing skull base artifacts in images%优化扫描方案减轻双排螺旋CT颅底伪影的研究

    Institute of Scientific and Technical Information of China (English)

    何新华; 胡永胜; 杨越; 胡鹏程; 王自勇; 付璇; 慕鹏

    2014-01-01

    目的:优化扫描方案,减少颅底伪影,改善图像质量。方法双排螺旋CT头颅平扫病例60例,随机分为3组,每组20例。 A、B组采用常规序列扫描,A组层厚为8 mm (4.0 mm ×2),B组层厚为4 mm(4.0 mm ×2)。 C组采用2段螺旋扫描程序,扫描参数为颅底3 mm (1.5 mm ×2)+颅脑幕上5 mm(2.5 mm ×2)。观察和评价后、中颅窝图像有无伪影、伪影形态、位置、严重程度等。结果除A组1例外,A、B两组后颅窝均有不同程度的放射状伪影和交叉伪影,中颅窝部分病例有不同程度伪影。 B组Ⅱ级伪影的总数多于A组(29/16),Ш级伪影2例,显示B组4 mm层厚不能减轻颅底伪影,且有加重伪影程度的可能。 C组中部分病例后颅窝、中颅窝未见明显伪影,Ⅱ级伪影的例数为5例。与A、B组比较, C组可显著减轻颅底伪影,差异有统计学意义(P<0.05)。结论颅底3 mm (1.5 mm ×2)+颅脑幕上5 mm(2.5 mm ×2)螺旋扫描法,可显著减轻颅底伪影,改善图像质量,清晰显示颅底组织结构,具有临床应用价值。%Objective To optimize the scanning programs in order to reduce the skull base artifacts and improve images quality . Methods Sixty cases of brain performed with double helical CT were randomly divided into three groups with 20 in each.Group A and B u-sing routine sequential program ,the thickness was 8mm (4.0 mm ×2) in group A and was 4mm (4.0 mm ×2) in group B.Group C using two segments helical scan,the thickness for the base of the skull (Base) was 3mm (1.5 mm ×2),and for cerebrum (above brain curtain) was 5 mm (2.5 mm ×2).The artifacts shape,location,severity at posterior fossa,and middle cranial fossa images were observed and evalua-ted.Results In group A and B ,almost all cases had varying severity of radial and cross artifacts at posterior fossa ,and had different degrees of artifacts at middle cranial fossa in

  13. Overview of multisource CT systems and methods

    Science.gov (United States)

    Zhao, Jun; Lu, Yang; Zhuang, Tiange; Wang, Ge

    2010-09-01

    Multiple-source cone-beam scanning is a promising mode for dynamic volumetric CT/micro-CT. The first dynamic CT system is the Dynamic Spatial Reconstructor (DSR) built in 1979. The pursuance for higher temporal resolution has largely driven the development of CT technology, and recently led to the emergence of Siemens dual-source CT scanner. Given the impact and limitation of dual-source cardiac CT, triple-source cone-beam CT seems a natural extension for future cardiac CT. Our work shows that trinity (triple-source architecture) is superior to duality (dual-source architecture) for helical cone-beam CT in terms of exact reconstruction. In particular, a triple-source helical scan allows a perfect mosaic of longitudinally truncated cone-beam data to satisfy the Orlov condition and yields better noise performance than the dual-source counterpart. In the (2N+1)-source helical CT case, the more sources, the higher temporal resolution. In the N-source saddle CT case, a triple-source scan offers the best temporal resolution for continuous dynamic exact reconstruction of a central volume. The recently developed multi-source cone-beam algorithms include an exact backprojection-filtration (BPF) approach and a "slow" exact filtered-backprojection (FBP) algorithm for (2N+1)-source helical CT, two fast quasi-exact FBP algorithms for triple-source helical CT, as well as a fast exact FBP algorithm for triple-source saddle CT. Some latest ideas will be also discussed, such as multi-source interior tomography and multi-beam field-emission x-ray CT.

  14. Metal separations using aqueous biphasic partitioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Chaiko, D.J.; Zaslavsky, B.; Rollins, A.N.; Vojta, Y.; Gartelmann, J.; Mego, W. [Argonne National Lab., IL (United States). Chemical Technology Div.

    1996-05-01

    Aqueous biphasic extraction (ABE) processes offer the potential for low-cost, highly selective separations. This countercurrent extraction technique involves selective partitioning of either dissolved solutes or ultrafine particulates between two immiscible aqueous phases. The extraction systems that the authors have studied are generated by combining an aqueous salt solution with an aqueous polymer solution. They have examined a wide range of applications for ABE, including the treatment of solid and liquid nuclear wastes, decontamination of soils, and processing of mineral ores. They have also conducted fundamental studies of solution microstructure using small angle neutron scattering (SANS). In this report they review the physicochemical fundamentals of aqueous biphase formation and discuss the development and scaleup of ABE processes for environmental remediation.

  15. Biphase sinusoidal oscillator based on negative resistor.

    Science.gov (United States)

    Bayard, Jean

    2010-06-01

    This paper describes a biphase sinusoidal generator which provides two signals: v(ref)=V(M) sin(omegat) and v(out)=V(M) sin(omegat+DeltaPhi), where DeltaPhi is in the range 0, pi/2 or -pi/2, 0 and is not dependent on the frequency value. It is based on a negative resistor and it requires very few components. SPICE simulations and measurements on an experimental setup confirm the theoretical analysis.

  16. Helical surface structures

    CERN Document Server

    Brandenburg, A; Brandenburg, Axel; Blackman, Eric G.

    2002-01-01

    Over the past few years there has been growing interest in helical magnetic field structures seen at the solar surface, in coronal mass ejections, as well as in the solar wind. Although there is a great deal of randomness in the data, on average the extended structures are mostly left-handed on the northern hemisphere and right-handed on the southern. Surface field structures are also classified as dextral (= right bearing) and sinistral (= left bearing) occurring preferentially in the northern and southern hemispheres respectively. Of particular interest here is a quantitative measurement of the associated emergence rates of helical structures, which translate to magnetic helicity fluxes. In this review, we give a brief survey of what has been found so far and what is expected based on models. Particular emphasis is put on the scale dependence of the associated fields and an attempt is made to estimate the helicity flux of the mean field vs. fluctuating field.

  17. Helical CT of the abdomen: whole milk as a low-density oral contrast agent; Tomografia helicoidal do abdome: avaliacao do leite integral como contraste oral de baixa densidade

    Energy Technology Data Exchange (ETDEWEB)

    Collares, Felipe Birchal; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho; Moreira, Wanderval; Ribeiro, Marcelo Almeida [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Dept. de Radiologia

    2000-08-01

    We evaluated 90 abdominal helical computed tomography scans from patients who received 1% iodine solution, whole milk or no oral contrast agent before scanning. Four parameters were evaluated: gastrointestinal distension, mural visualization, pancreas-duodenum discrimination and bowel loop discrimination. Better results were obtained with the use of whole milk compared to iodine contrast or no oral contrast agent. Whole milk is an effective low density oral contrast agent. (author)

  18. Helical superconducting black holes.

    Science.gov (United States)

    Donos, Aristomenis; Gauntlett, Jerome P

    2012-05-25

    We construct novel static, asymptotically five-dimensional anti-de Sitter black hole solutions with Bianchi type-VII(0) symmetry that are holographically dual to superconducting phases in four spacetime dimensions with a helical p-wave order. We calculate the precise temperature dependence of the pitch of the helical order. At zero temperature the black holes have a vanishing entropy and approach domain wall solutions that reveal homogenous, nonisotropic dual ground states with an emergent scaling symmetry.

  19. Helical computed tomography in the assessment of abdominal aortic pathology

    Energy Technology Data Exchange (ETDEWEB)

    Vicaretti, M.; Young, N.; Jenkins, J.; Fletcher, J. [Westmead Hospital, Westmead, NSW (Australia)

    1997-05-01

    A pilot study was undertaken to evaluate the role of helical computed tomography in the assessment of abdominal aortic pathology. A total of 17 patients underwent intra-arterial digital subtraction angiography (IADSA) and helical computed tomography, with eight patients undergoing subsequent operative intervention. A comparison of radiological findings between IADSA and helical computed tomography (CT) was made and, where applicable, a comparison was made with operative findings. Pathology included abdominal aortic aneurysm (AAA) (n=12), thoraco abdominal aneurysm (n=2) and dissection (n=1), graft distension following AAA repair (n=1) and plaque haemorrhage in the distal aorta following percutaneous transluminal angioplasty (PTA) of the iliac artery (n=1). Planned operative management as based on pre-operative helical CT imaging findings, in particular with reference to the type of graft used (straight or bifurcated) was not changed at operation. Our findings on helical CT in regards to AAA, thoraco-abdominal aneurysm and dissection correlated well with angiography and surgery findings. (authors). 26 refs., 2 tabs., 5 figs.

  20. CT evaluation of solitary pulmonary nodule : value of additional HRCT scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Kwak Jin Young; Lee, Seung Ik; Ha, Doo Hoe [Pundang CHA General Hospital, Pochon CHA Univ. College of Medicine, Sungnam (Korea, Republic of); Kim, Tae Sung; Hwang, Jung Hwa; Lee, Kyung Soo [Samsung Medical Center, Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of); Kim, Yook Yung [Ewha Womans Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-04-01

    The aim of our study was to evaluate the usefulness of high-resolution CT scans in addition to helical CT for characterizing a solitary pulmonary nodule. Our study included 49 patients with a solitary pulmonary nodule ; in each patient this was evaluated by both additional high-resolution CT and helical scanning. Images were evaluated by three independent observers, each of whom read them twice : initially with helical CT images only and then with helical images plus high-resolution CT images. After analysis, the observers recorded the following : histologic diagnosis, benignancy or malignancy of a nodule, and confidence in their diagnosis (three scales). In differentiating benign and malignant nodules, the accuracy of helical scans only was 75% (110/147 readings) whereas that of helical plus high-resolution CT scans was 82% (121/147 readings)({rho}=0.001). Correct histologic diagnosis was made in 47% of cases (69/147 readings) when helical scans only had been evaluated and in 48% of cases (71/147 readings) for which both helical and high-resolotion CT scans were available ({rho}=0.815). Diagnosis was more often highly confident on the basis of additional high-resolution CT scans (25%) than helical scans only (5%) ({rho}=0.001). By enhancing differential diagnostic accuracy between benign and malignant nodules and by increasing confidence in the histologic diagnosis of a pulmonary nodule, additional high-resolution CT scans are valuable for the evaluation of a solitary pulmonary nodule.

  1. Helicity, Reconnection, and Dynamo Effects

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Hantao

    1998-11-01

    The inter-relationships between magnetic helicity, magnetic reconnection, and dynamo effects are discussed. In laboratory experiments, where two plasmas are driven to merge, the helicity content of each plasma strongly affects the reconnection rate, as well as the shape of the diffusion region. Conversely, magnetic reconnection events also strongly affect the global helicity, resulting in efficient helicity cancellation (but not dissipation) during counter-helicity reconnection and a finite helicity increase or decrease (but less efficiently than dissipation of magnetic energy) during co-helicity reconnection. Close relationships also exist between magnetic helicity and dynamo effects. The turbulent electromotive force along the mean magnetic field (alpha-effect), due to either electrostatic turbulence or the electron diamagnetic effect, transports mean-field helicity across space without dissipation. This has been supported by direct measurements of helicity flux in a laboratory plasma. When the dynamo effect is driven by electromagnetic turbulence, helicity in the turbulent field is converted to mean-field helicity. In all cases, however, dynamo processes conserve total helicity except for a small battery effect, consistent with the observation that the helicity is approximately conserved during magnetic relaxation.

  2. Mathisson's helical motions demystified

    CERN Document Server

    Costa, L Filipe O; Zilhão, Miguel

    2012-01-01

    The motion of spinning test particles in general relativity is described by Mathisson-Papapetrou-Dixon equations, which are undetermined up to a spin supplementary condition, the latter being today still an open question. The Mathisson-Pirani (MP) condition is known to lead to rather mysterious helical motions which have been deemed unphysical, and for this reason discarded. We show that these assessments are unfounded and originate from a subtle (but crucial) misconception. We discuss the kinematical explanation of the helical motions, and dynamically interpret them through the concept of hidden momentum, which has an electromagnetic analogue. We also show that, contrary to previous claims, the frequency of the helical motions coincides exactly with the zitterbewegung frequency of the Dirac equation for the electron.

  3. Helical plasma thruster

    Energy Technology Data Exchange (ETDEWEB)

    Beklemishev, A. D., E-mail: bekl@bk.ru [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation)

    2015-10-15

    A new scheme of plasma thruster is proposed. It is based on axial acceleration of rotating magnetized plasmas in magnetic field with helical corrugation. The idea is that the propellant ionization zone can be placed into the local magnetic well, so that initially the ions are trapped. The E × B rotation is provided by an applied radial electric field that makes the setup similar to a magnetron discharge. Then, from the rotating plasma viewpoint, the magnetic wells of the helically corrugated field look like axially moving mirror traps. Specific shaping of the corrugation can allow continuous acceleration of trapped plasma ions along the magnetic field by diamagnetic forces. The accelerated propellant is expelled through the expanding field of magnetic nozzle. By features of the acceleration principle, the helical plasma thruster may operate at high energy densities but requires a rather high axial magnetic field, which places it in the same class as the VASIMR{sup ®} rocket engine.

  4. A Framework for the Modelling of Biphasic Reacting Systems

    DEFF Research Database (Denmark)

    Anantpinijwatna, Amata; Sin, Gürkan; O’Connell, John P.

    2014-01-01

    Biphasic reacting systems have a broad application range from organic reactions in pharmaceutical and agro-bio industries to CO 2 capture. However, mathematical modelling of biphasic reacting systems is a formidable challenge due to many phenomena underlying the process such as chemical equilibri...... systems: a PTC-based reaction system and pseudo-PTC system....

  5. AQUEOUS BIPHASE EXTRACTION FOR PROCESSING OF FINE COAL

    Energy Technology Data Exchange (ETDEWEB)

    K. Osseo-Asare; X. Zeng

    2002-01-01

    The objective of this research project is to develop an aqueous biphase extraction process for the treatment of fine coals. Aqueous biphase extraction is an advanced separation technology that relies on the ability of an aqueous system consisting of a water-soluble polymer and another component, e.g., another polymer, an inorganic salt, or a nonionic surfactant, to separate into two immiscible aqueous phases. The principle behind the partition of solid particles in aqueous biphase systems is the physicochemical interaction between the solid surface and the surrounding liquid solution. In order to remove sulfur and mineral matter from fine coal with aqueous biphasic extraction, it is necessary to know the partitioning behavior of coal, as well as the inorganic mineral components. Therefore, in this research emphasis was placed on the partitioning behavior of fine coal particles as well as model fine inorganic particles in aqueous biphase systems.

  6. 螺旋CT多期扫描测定肾移植供体肾功能的价值%Glomerular filtration rate in living renal donor measured by helical CT multi-phase scanning

    Institute of Scientific and Technical Information of China (English)

    窦鑫; 周科峰; 李丹燕; 胡安宁; 杨尚文; 郭宏骞; 刘铁石; 朱斌

    2011-01-01

    目的:评价多层螺旋CT多期扫描测定肾移植供体肾功能的方法及应用.方法:58例活体肾移植供体行腹部多层螺旋CT多期(动脉期、实质期、排泄期)扫描,在动脉期与实质期之间插入5个低剂量全肾扫描序列,数据传入AW4.2工作站进行测量,根据全肾Patlak方程,计算单侧肾小球滤过率(glomerular filtration rate,GFR),同时与单光子发射计算机体层成像(single photon emission computed tomography,SPECT)所测定的单侧GFR相对照,进行直线回归与相关分析.结果:两种方法测定的GFR相关性良好,总肾的GFR相关系数r=0.904,直线回归方程为GFR(CT)=20.841+0.753×GFR(ECT),n=58,单侧GFR相关系数r=0.946,直线回归方程为GFR(CT)=7.086+0.864×GFR(ECT),n=116,配对t检验显示,两者测定的单侧及双侧GFR之间均无显著性差异(P>0.05).结论:螺旋CT多期扫描测定的移植肾供体的GFR结果准确,可以和同位素测定结果相互替代.%Objective:To evaluate the technique and application for measuring glomerular filtration rate in living renal donor by 16-slice spiral CT multi-phase scanning. Methods:58 living renal donors were underwent abdominal multi-phase enhancement CT scan, between the arterial and parenchymal phase. 5 continuous low dose kidney series were inserted. Using the known patlak equation, the GFR in a single kidney was calculated in CT scan and the exact information of GFR was gained by performing renal SPECT with Tc99m-TDPA. GFR of the two groups were analyzed by linear regression analysis. Results: Linear regression analysis show that the two groups GFR had very well associativity. The correlation coefficient of whole kidney and divided one is 0. 904 and 0. 946. With a line of regression GFR(CT) = 20. 841 + 0. 753 × GFR (ECT).n=58(the whole kidney); GFR(CT)=7. 086 + 0. 864 XGFR(ECT) .n= 116 (the divided kidney), they had no statistical significance in pair t test( P >0. 05). Conclusion:The GRF measured by multi-phase CT

  7. Imaging bowel obstruction: A comparison between fast magnetic resonance imaging and helical computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Beall, D.P.; Fortman, B.J.; Lawler, B.C.; Regan, F

    2002-08-01

    AIM: To compare the accuracy of fast magnetic resonance (MR) imaging using the half-Fourier single shot turbo spin echo (HASTE) sequence with helical computed tomography (CT) in diagnosing bowel obstruction. MATERIALS AND METHODS: Prospective evaluation of 44 patients with clinical evidence of bowel obstruction was conducted using various investigations including HASTE MR and helical CT. MR was performed with a Siemens 1.5 Tesla MR Imaging System and CT was performed with one of two Siemens ARHP CT systems using helical technique. MR acquisition allowed data to be gathered in 6-10 minutes and no contrast media were administered. CT imaging consisted of consecutive helical CT through the abdomen and pelvis with oral and intravenous contrast medium used when indicated. Bowel dilation along with the presence and level of obstruction were determined. RESULTS: Twenty-eight patients had bowel obstruction confirmed at laparotomy or by radiographic assessment. Of these, 25 had small bowel obstruction and three had colonic obstructions. The obstruction was due to fibrous adhesions in nine patients, metastases or primary carcinoma in seven, Crohn's disease in four, hernias in two, and inflammation or abscess in two. Other causes of obstruction included lymphoma, intussusception and anastomotic stricture. The cause of obstruction was correctly diagnosed by CT in 71%, and by MR in 95% of cases. The sensitivity, specificity and accuracy for HASTE MR imaging was 95%, 100% and 96% respectively as compared to 71%, 71% and 71% for helical CT. CONCLUSION: Fast MR imaging using the HASTE sequence is more accurate than helical CT in diagnosing bowel obstruction. Beall, D.P. et al. (2002)

  8. Lung scintigraphy and helical computed tomography for the diagnosis of pulmonary embolism : A meta-analysis

    NARCIS (Netherlands)

    van Beek, EJR; Brouwers, EMJ; Song, B; Bongaerts, AHH; Oudkerk, M

    To assess the diagnostic value of lung scintigraphy and helical computed tomography (hCT) in patients with suspected pulmonary embolism (PE), all English-language articles that described lung scintigraphy and hCT in patients with suspected PE were retrieved. Articles were assessed for strength of

  9. Flat Helical Nanosieves

    CERN Document Server

    Mei, Shengtao; Hussain, Sajid; Huang, Kun; Ling, Xiaohui; Siew, Shawn Yohanes; Liu, Hong; Teng, Jinghua; Danner, Aaron; Qiu, Cheng-Wei

    2016-01-01

    Compact and miniaturized devices with flexible functionalities are always highly demanded in optical integrated systems. Plasmonic nanosieve has been successfully harnessed as an ultrathin flat platform for complex manipulation of light, including holography, vortex generation and non-linear processes. Compared with most of reported single-functional devices, multi-functional nanosieves might find more complex and novel applications across nano-photonics, optics and nanotechnology. Here, we experimentally demonstrate a promising roadmap for nanosieve-based helical devices, which achieves full manipulations of optical vortices, including its generation, hybridization, spatial multiplexing, focusing and non-diffraction propagation etc., by controlling the geometric phase of spin light via over 121 thousands of spatially-rotated nano-sieves. Thanks to such spin-conversion nanosieve helical elements, it is no longer necessary to employ the conventional two-beam interferometric measurement to characterize optical ...

  10. Helices and vector bundles

    CERN Document Server

    Rudakov, A N

    1990-01-01

    This volume is devoted to the use of helices as a method for studying exceptional vector bundles, an important and natural concept in algebraic geometry. The work arises out of a series of seminars organised in Moscow by A. N. Rudakov. The first article sets up the general machinery, and later ones explore its use in various contexts. As to be expected, the approach is concrete; the theory is considered for quadrics, ruled surfaces, K3 surfaces and P3(C).

  11. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  12. Nonlinear helical MHD instability

    Energy Technology Data Exchange (ETDEWEB)

    Zueva, N.M.; Solov' ev, L.S.

    1977-07-01

    An examination is made of the boundary problem on the development of MHD instability in a toroidal plasma. Two types of local helical instability are noted - Alfven and thermal, and the corresponding criteria of instability are cited. An evaluation is made of the maximum attainable kinetic energy, limited by the degree to which the law of conservation is fulfilled. An examination is made of a precise solution to a kinematic problem on the helical evolution of a cylindrical magnetic configuration at a given velocity distribution in a plasma. A numerical computation of the development of MHD instability in a plasma cylinder by a computerized solution of MHD equations is made where the process's helical symmetry is conserved. The development of instability is of a resonance nature. The instability involves the entire cross section of the plasma and leads to an inside-out reversal of the magnetic surfaces when there is a maximum unstable equilibrium configuration in the nonlinear stage. The examined instability in the tore is apparently stabilized by a magnetic hole when certain limitations are placed on the distribution of flows in the plasma. 29 references, 8 figures.

  13. [Proper technics and the reduction of radiation in helical computed tomography].

    Science.gov (United States)

    Cordoliani, Y S; Hazebroucq, V; Sarrazin, J L; Lévêque, C; Marque, B; Goasdoué, P

    1999-02-01

    Helical computed tomography is the main source of ionizing radiation delivery in diagnostic radiology. For each series, average radiation dose is between 20 and 30 mGy. This dose can potentially be reduced by decreasing intensity or voltage and by increasing pitch. Helical acquisition allows reformating of images with smaller increment or different obliquity, and avoids additional irradiation. Hardware and software devices designed for dose reduction must be systematically used. Users of CT systems should be aware of radiation dose delivered with CT and must carefully assess the need of each additional acquisition. Obsolete habits, as gantry tilting for lumbar CT, which increases patient exposure, must be given up. Rational use of helical CT decreases radiation exposure and gains time, whereas thoughtless use increases radiation exposure without real benefit.

  14. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiromichi; Abe, Kimihiko [Tokyo Medical Coll. (Japan); Freeny, P.C.

    1996-03-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author).

  15. Thermal stability of hydroxyapatite in biphasic calcium phosphate ceramics

    CSIR Research Space (South Africa)

    Nilen, RWN

    2008-04-01

    Full Text Available Biphasic calcium phosphate ceramics (BCP) comprising a mix of non-resorbable hydroxyapatite (HA) and resorbable b-tricalcium phosphate (b-TCP) are particularly suitable materials for synthetic bone substitute applications. In this study, HA...

  16. Thoracic CT

    Science.gov (United States)

    ... lungs; CT scan - chest Images CT scan Thyroid cancer - CT scan Pulmonary nodule, solitary - CT scan Lung mass, right upper ... Chest Injuries and Disorders CT Scans Emphysema Lung Cancer Lung Diseases Pleural Disorders Pneumonia Pulmonary Embolism Tuberculosis Browse the Encyclopedia A.D.A. ...

  17. Acute encephalopathy with biphasic seizures and late reduced diffusion

    Directory of Open Access Journals (Sweden)

    Saroj S Yadav

    2013-01-01

    Full Text Available Acute encephalopathy with biphasic seizures and reduced diffusion (AESD is a syndrome of encephalopathy characterized by biphasic seizures and altered consciousness in the acute stage followed in the subacute stage by restricted diffusion in the subcortical white matter on magnetic resonance imaging. The etiology of AESD has been attributed to viral infection like influenza A and human herpes virus 6. The exact pathogenesis of AESD is uncertain. Here we report a case of AESD, diagnosed based on clinicoradiological correlation.

  18. Comparison of Helical tomotherapy and Cyberknife in Spine Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Nam; Yoon, Se Chul; Chi, Byung Ok; Jng, Hong Suk; Sohn, Suk Hyun [Seoul ST.Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of); Jung, Gee Young; Shin, Heon Ju; Choi, Ilbong; Gea, Cheol Seong [Incheon ST.Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of); Kim, Hee Jong [Dept. of Radiation Oncology, Yonsei University, Seoul (Korea, Republic of)

    2011-04-15

    The purpose of this study is planning comparison of helicaltomotherapy and Cyber knife in spine radiosurgery. Spine radiosurgery is an alternative to invasive spine surgery. The tomotherapy is megavoltage CT(MVCT) based image guided helical IMRT delivery system. The cyberknife using robotic arm and image guided based fiducial marker killo voltage X-ray image. The helical tomotherapy is modulated by a 64-multileaf collimator that has paired, pneumatically driven, 6.25-mm-wide leaves calculated to open or close at approximately every 7 .deg. of LINAC rotation, or 51 times per gantry rotation. But cyber knife use 100 or more than bean path. Although, cord maximum dose in CKP is lower than HTP, target homogeneity in HTP is better than CKP. Target coverage is 85% in CKP, 92% in HTP. It was benefit of helical radiation therapy. Tomotheapy and cyberknife are useful equipment to spine radiosurgery.

  19. Helicity Transfer in Turbulent Models

    CERN Document Server

    Biferale, L; Toschi, F

    1998-01-01

    Helicity transfer in a shell model of turbulence is investigated. We show that a Reynolds-independent helicity flux is present in the model when the large scale forcing breaks inversion symmetry. The equivalent in Shell Models of the ``2/15 law'', obtained from helicity conservation in Navier-Stokes eqs., is derived and tested. The odd part of helicity flux statistic is found to be dominated by a few very intense events. In a particular model, we calculate analytically leading and sub-leading contribution to the scaling of triple velocity correlation.

  20. 3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Frericks, Bernd B. [Medizinische Hochschule Hannover, Diagnostische Radiologie, Hannover (Germany); Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Benjamin Franklin, Freie Universitaet Berlin, Hindenburgdamm 30, 12200, Berlin (Germany); Caldarone, Franco C.; Savellano, Dagmar Hoegemann; Stamm, Georg; Kirchhoff, Timm D.; Shin, Hoen-Oh; Galanski, Michael [Medizinische Hochschule Hannover, Diagnostische Radiologie, Hannover (Germany); Nashan, Bjoern; Klempnauer, Juergen [Medizinische Hochschule Hannover, Viszeral und Transplantationschirurgie, Hannover (Germany); Schenk, Andrea; Selle, Dirk; Spindler, Wolf; Peitgen, Heinz-Otto [Centrum fuer Medizinische Diagnosesysteme und Visualisierung, Bremen (Germany)

    2004-02-01

    The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110{+-}180 ml for right lobes, 820 ml for the left lobe and 270{+-}30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments. (orig.)

  1. Primary localized malignant biphasic mesothelioma of the liver in a patient with asbestosis

    Institute of Scientific and Technical Information of China (English)

    Motoko Sasaki; Ichiro Araki; Toshiaki Yasui; Masaru Kinoshita; Keita Itatsu; Takayuki Nojima; Yasuni Nakanuma

    2009-01-01

    We report a case of primary localized malignant biphasic mesothelioma of the liver in a 66-yearold man associated with asbestosis. The tumor was detected as a hepatic nodule, 4 cm in diameter, in the right lobe (S8 segment) on CT scan. Histopathological examination demonstrated an intrahepatic tumor with central necrosis consisting of a papillary epithelioid pattern on the surface of the liver, microcystic (microglandular or adenomatoid) pattern mainly in the subcapsular area and sarcomatoid pattern intermingled with microcystic pattern in the major part of the hepatic nodular tumor. Tumor cells, especially of epithelioid type, showed distinct immunoreactivity for mesothelial markers (WT-1, calretinin, D2-40, CK5/6,mesothelin, thrombomodulin) and no immunoreactivity for epithelial (adenocarcinoma) markers (CEA, CD15,BerEP4, BG8, MOC31). P53 immunoreactivity was detected focally in papillary epithelioid tumor cells and extensively in microcystic and sarcomatoid components, suggesting that the papillary epithelioid mesothelioma arose on the surface of the liver, and tumor cells showing microcystic and sarcomatoid patterns invaded and grew into the liver. To date, this is the first case of primary localized malignant biphasic mesothelioma of the liver, since all three primary hepatic mesotheliomas reported so far were epithelioid type.

  2. Employing Helicity Amplitudes for Resummation

    NARCIS (Netherlands)

    Moult, I.; Stewart, I.W.; Tackmann, F.J.; Waalewijn, W.J.

    2015-01-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are dire

  3. Quark Helicity and Transversity Distributions

    CERN Document Server

    Hwang, Dae Sung

    2016-01-01

    The quark transversity distribution inside nucleon is less understood than the quark unpolarized and helicity distributions inside nucleon. In particular, it is important to know clearly why the quark helicity and transversity distributions are different. We investigate the origin of their discrepancy.

  4. Magnetic design constraints of helical solenoids

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, M. L. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Krave, S. T. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Tompkins, J. C. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Yonehara, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Flanagan, G. [Muons Inc., Batavia, IL (United States); Kahn, S. A. [Muons Inc., Batavia, IL (United States); Melconian, K. [Texas A & M Univ., College Station, TX (United States)

    2015-01-30

    Helical solenoids have been proposed as an option for a Helical Cooling Channel for muons in a proposed Muon Collider. Helical solenoids can provide the required three main field components: solenoidal, helical dipole, and a helical gradient. In general terms, the last two are a function of many geometric parameters: coil aperture, coil radial and longitudinal dimensions, helix period and orbit radius. In this paper, we present design studies of a Helical Solenoid, addressing the geometric tunability limits and auxiliary correction system.

  5. The Advanced Helical Generator

    Energy Technology Data Exchange (ETDEWEB)

    Reisman, D B; Javedani, J B; Ellsworth, G F; Kuklo, R M; Goerz, D A; White, A D; Tallerico, L J; Gidding, D A; Murphy, M J; Chase, J B

    2009-10-26

    A high explosive pulsed power (HEPP) generator called the Advanced Helical Generator (AHG) has been designed, built, and successfully tested. The AHG incorporates design principles of voltage and current management to obtain a high current and energy gain. Its design was facilitated by the use of modern modeling tools as well as high precision manufacture. The result was a first-shot success. The AHG delivered 16 Mega-Amperes of current and 11 Mega-Joules of energy to a quasi-static 80 nH inductive load. A current gain of 154 times was obtained with a peak exponential rise time of 20 {micro}s. We will describe in detail the design and testing of the AHG.

  6. Helicity dependent parton distributions

    CERN Document Server

    Scopetta, Sergio; 10.4249/scholarpedia.10226

    2011-01-01

    The helicity dependent parton distributions describe the number density of partons with given longitudinal momentum x and given polarization in a hadron polarized longitudinally with respect to its motion. After the discovery, more than 70 years ago, that the proton is not elementary, the observation of Bjorken scaling in the late 1960s lead to the idea of hadrons containing almost pointlike constituents, the partons. Since then, Deep Inelastic Scattering (DIS) has played a crucial role in our understanding of hadron structure. Through DIS experiments it has been possible to link the partons to the quarks, and to unveil the presence of other pointlike constituents, the gluons, which lead into a dynamical theory of quarks and gluons - quantum chromodynamics (QCD). Polarized DIS, i.e. the collision of a longitudinally polarized lepton beam on a polarized target (either longitudinally or transversely polarized), provides a complementary information regarding the structure of the nucleon. Whereas ordinary DIS pro...

  7. Biphasic catalysis in water/carbon dioxide micellar systems

    Science.gov (United States)

    Jacobson, Gunilla B.; Tumas, William; Johnston, Keith P.

    2002-01-01

    A process is provided for catalyzing an organic reaction to form a reaction product by placing reactants and a catalyst for the organic reaction, the catalyst of a metal complex and at least one ligand soluble within one of the phases of said aqueous biphasic system, within an aqueous biphasic system including a water phase, a dense phase fluid, and a surfactant adapted for forming an emulsion or microemulsion within the aqueous biphasic system, the reactants soluble within one of the phases of the aqueous biphasic system and convertible in the presence of the catalyst to a product having low solubility in the phase in which the catalyst is soluble; and, maintaining the aqueous biphasic system under pressures, at temperatures, and for a period of time sufficient for the organic reaction to occur and form the reaction product and to maintain sufficient density on the dense phase fluid, the reaction product characterized as having low solubility in the phase in which the catalyst is soluble.

  8. Progress on the biphase turbine at Cerro Prieto

    Energy Technology Data Exchange (ETDEWEB)

    Cerini, D.; Hays, L.; Studhalter, W. [Douglas Energy Company, Placentia, CA (United States)

    1997-12-31

    The status of a Biphase turbine power plant being installed at the Cerro Prieto geothermal field is presented. The major modules for the power plant are completed except for a back pressure steam turbine. The power plant will be started in April 1997 with the Biphase turbine alone followed by the addition of the steam turbine module two months later. The current power plant performance level is 2780 kWe due to a decline in the well. An increase in power output to 4060 kWe by adding the flow from another well is planned. The addition of five Biphase power plants with a total power output of 21.2 megawatts is described.

  9. Turbulent Dynamos and Magnetic Helicity

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Hantao

    1999-04-01

    It is shown that the turbulent dynamo alpha-effect converts magnetic helicity from the turbulent field to the mean field when the turbulence is electromagnetic while the magnetic helicity of the mean-field is transported across space when the turbulence is elcetrostatic or due to the elcetron diamagnetic effect. In all cases, however, the dynamo effect strictly conserves the total helicity expect for a battery effect which vanishes in the limit of magnetohydrodynamics. Implications for astrophysical situations, especially for the solar dynamo, are discussed.

  10. SPring-8 twin helical undulator.

    Science.gov (United States)

    Hara, T; Tanaka, T; Tanabe, T; Maréchal, X M; Kumagai, K; Kitamura, H

    1998-05-01

    There are several ways of producing circularly polarized light, such as using asymmetric devices, crossed undulators etc. The SPring-8 helical undulator introduces a simple way of producing both horizontal and vertical fields in one undulator. All the magnet arrays are arranged above and below the plane of the electron orbit, so there is no limitation of access from the sides of the undulator. For the SPring-8 BL25SU, two helical undulators will be installed in tandem, and the helicity of the polarization can be switched at up to 10 Hz using five kicker magnets.

  11. Helical CT three-dimensional reconstruction for inferior cervical zygapophyseal joint and its clinic meaning%下颈椎关节突关节的影像学观测及其临床意义

    Institute of Scientific and Technical Information of China (English)

    曾辉; 邹德威; 吴继功; 马华松; 姬勇; 张乐乐

    2012-01-01

    目的:观测下颈椎关节突关节面的形态及其三维空间角度,探讨其临床意义.方法:选取60例正常人行颈椎CT检查,螺旋CT三维重建后在横轴面、矢状面、冠状面上观察颈椎关节突关节面形态特点,并测量关节面的曲度、关节突关节角.结果:横轴面,C3上关节面及C7的下关节面直面形多见.C3、C4、C5Ⅱ型关节面曲度比较无显著差异,C5~C7关节突关节面曲度逐渐变小(P<0.05).C3-C4、C4-C5、C5-C6、C6-C7、C7-T1关节突关节面与矢状面的夹角分别为91.98°±9.92°、96.64°±9.01°、99.46°±7.66°、94.20°±8.72°、94.83°±10.88°,C4-C5、C5-C6夹角较大(P<0.05).冠状面,C6/7节段椭圆形多见,C2/3、C3/4节段圆形多见.矢状面,下颈椎C3~C7关节突关节倾角分别为52.09°±6.28°、48.14°±4.75°、45.81°±4.07°、55.65°±4.15°、58.32°±5.77°,C3、C6、C7与C5关节突关节倾角之间差异显著(P<0.05).结论:正常人下颈椎关节突关节形态在诸节段及横轴面、冠状面不尽相同.横轴面上,C3~C7的上关节面的方向逐渐从朝向正中矢状面转向外侧,渐渐与胸椎的小关节相适应,矢状面上,C3~C7的关节倾角均为锐角,且以C5为中心分布.%Objective:To study the three-dimensional quantitative morphology as well as the orientation of cervical zygapophyseal joint and their clinical significances.Method:The cervical zygapophyseal joints of 60 normal volunteers were scanned using spiral CT and reconstructed three-dimensionally .The shapes,curvatures and angulations of these joints were observed and measured in the cross-sectional,sagittal and coronal planes respectively.Result:At the cross-sectional plane,the superior facet joint of C3 and the inferior facet joint of C7 presented with face-type frequently .The C-shape articular surfaces in C3,C4,C5 showed no statistic sig-nificance.The angles of the articular facet orientation at C3/4, C4/5, C5/6, C6/7 and C7/T1 were 91.98°±9

  12. Decay of helical and non-helical magnetic knots

    CERN Document Server

    Candelaresi, Simon

    2011-01-01

    We present calculations of the relaxation of magnetic field structures that have the shape of particular knots and links. A set of helical magnetic flux configurations is considered, which we call $n$-foil knots of which the trefoil knot is the most primitive member. We also consider two non-helical knots, namely the Borromean rings as well as a single interlocked flux rope that also serves as the logo of the Inter-University Centre for Astronomy and Astrophysics in Pune, India. The field decay characteristics of both configurations is investigated and compared with previous calculations of helical and non-helical triple ring configurations. For the $n$-foil knots the decay is described by power laws that range form $t^{-2/3}$ to $t^{-1/3}$, which can be as slow as the $t^{-1/3}$ behavior for helical triple-ring structures that was seen in earlier work. The two non-helical configurations decay like $t^{-1}$, which is somewhat slower than the previously obtained $t^{-3/2}$ behavior in the decay of interlocked ...

  13. Magnetic Helicity and Planetary Dynamos

    Science.gov (United States)

    Shebalin, John V.

    2012-01-01

    A model planetary dynamo based on the Boussinesq approximation along with homogeneous boundary conditions is considered. A statistical theory describing a large-scale MHD dynamo is found, in which magnetic helicity is the critical parameter

  14. Asymmetric catalysis with helical polymers

    NARCIS (Netherlands)

    Megens, Rik P.; Roelfes, Gerard

    Inspired by nature, the use of helical biopolymer catalysts has emerged over the last years as a new approach to asymmetric catalysis. In this Concept article the various approaches and designs and their application in asymmetric catalysis will be discussed.

  15. Asymmetric catalysis with helical polymers

    NARCIS (Netherlands)

    Megens, Rik P.; Roelfes, Gerard

    2011-01-01

    Inspired by nature, the use of helical biopolymer catalysts has emerged over the last years as a new approach to asymmetric catalysis. In this Concept article the various approaches and designs and their application in asymmetric catalysis will be discussed.

  16. Modeling helicity dissipation-rate equation

    CERN Document Server

    Yokoi, Nobumitsu

    2016-01-01

    Transport equation of the dissipation rate of turbulent helicity is derived with the aid of a statistical analytical closure theory of inhomogeneous turbulence. It is shown that an assumption on the helicity scaling with an algebraic relationship between the helicity and its dissipation rate leads to the transport equation of the turbulent helicity dissipation rate without resorting to a heuristic modeling.

  17. The next large helical devices

    Science.gov (United States)

    Iiyoshi, Atsuo; Yamazaki, Kozo

    1995-06-01

    Helical systems have the strong advantage of inherent steady-state operation for fusion reactors. Two large helical devices with fully superconducting coil systems are presently under design and construction. One is the LHD (Large Helical Device) [Fusion Technol. 17, 169 (1990)] with major radius=3.9 m and magnetic field=3-4 T, that is under construction during 1990-1997 at NIFS (National Institute for Fusion Science), Nagoya/Toki, Japan; it features continuous helical coils and a clean helical divertor focusing on edge configuration optimization. The other one in the W7-X (Wendelstein 7-X) [in Plasma Physics and Controlled Fusion Nuclear Research, 1990, (International Atomic Energy Agency, Vienna, 1991), Vol. 3, p. 525] with major radius=5.5 m and magnetic field=3 T, that is under review at IPP (Max-Planck Institute for Plasma Physics), Garching, Germany; it has adopted a modular coil system after elaborate optimization studies. These two programs are complementary in promoting world helical fusion research and in extending the understanding of toroidal plasmas through comparisons with large tokamaks.

  18. omega-Helices in proteins.

    Science.gov (United States)

    Enkhbayar, Purevjav; Boldgiv, Bazartseren; Matsushima, Norio

    2010-05-01

    A modification of the alpha-helix, termed the omega-helix, has four residues in one turn of a helix. We searched the omega-helix in proteins by the HELFIT program which determines the helical parameters-pitch, residues per turn, radius, and handedness-and p = rmsd/(N - 1)(1/2) estimating helical regularity, where "rmsd" is the root mean square deviation from the best fit helix and "N" is helix length. A total of 1,496 regular alpha-helices 6-9 residues long with p < or = 0.10 A were identified from 866 protein chains. The statistical analysis provides a strong evidence that the frequency distribution of helices versus n indicates the bimodality of typical alpha-helix and omega-helix. Sixty-two right handed omega-helices identified (7.2% of proteins) show non-planarity of the peptide groups. There is amino acid preference of Asp and Cys. These observations and analyses insist that the omega-helices occur really in proteins.

  19. Employing Helicity Amplitudes for Resummation

    CERN Document Server

    Moult, Ian; Tackmann, Frank J; Waalewijn, Wouter J

    2015-01-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are directly given in terms of color-ordered helicity amplitudes. Using this basis allows one to seamlessly combine fixed-order helicity amplitudes at any order they are known with a resummation of higher-order logarithmic corrections. In particular, the virtual loop amplitudes can be employed in factorization theorems to make predictions for exclusive jet cross sections without the use of numerical subtraction schemes to handle real-virtual infrared cancellations. We also discuss matching onto SCET in renormalization schemes with helicities in $4$- and $d$-dimensions. To demonstrate that our helicity operator basis is easy to use, we provide an explicit construction of the operator basis, as well as results for the hard m...

  20. Biphasic dose response in low level light therapy - an update.

    Science.gov (United States)

    Huang, Ying-Ying; Sharma, Sulbha K; Carroll, James; Hamblin, Michael R

    2011-01-01

    Low-level laser (light) therapy (LLLT) has been known since 1967 but still remains controversial due to incomplete understanding of the basic mechanisms and the selection of inappropriate dosimetric parameters that led to negative studies. The biphasic dose-response or Arndt-Schulz curve in LLLT has been shown both in vitro studies and in animal experiments. This review will provide an update to our previous (Huang et al. 2009) coverage of this topic. In vitro mediators of LLLT such as adenosine triphosphate (ATP) and mitochondrial membrane potential show biphasic patterns, while others such as mitochondrial reactive oxygen species show a triphasic dose-response with two distinct peaks. The Janus nature of reactive oxygen species (ROS) that may act as a beneficial signaling molecule at low concentrations and a harmful cytotoxic agent at high concentrations, may partly explain the observed responses in vivo. Transcranial LLLT for traumatic brain injury (TBI) in mice shows a distinct biphasic pattern with peaks in beneficial neurological effects observed when the number of treatments is varied, and when the energy density of an individual treatment is varied. Further understanding of the extent to which biphasic dose responses apply in LLLT will be necessary to optimize clinical treatments.

  1. Parallel-to-serial biphase-data converter

    Science.gov (United States)

    Truelove, R. D.

    1968-01-01

    Data converter produces a serial biphase output signal from parallel input data. Alternate bits are loaded into a shift register in complement form so that the bits appear at the end of the shift register in a true-complement form sequence.

  2. Comparison of Volume Rendering CT cholangiography and Minimum intensity projection CT cholangiography in patients with obstructive biliary disease

    OpenAIRE

    牛見, 尚史; 佃, 俊二; 平敷, 淳子

    2002-01-01

     We compared the detectability and conspicuity of minimum intensity projection CT cholangiography (Min-IP CTC)with volume rendering CT cholangiography (VRCTC).The subjects were ten patients (6 men, 4 women, mean age 64.7) who clinically suspected obstructive biliary truct disease. They underwent enhanced helical CT. Volume data of delayed phase that reconstructed by 2 or 1 mm thickness was transferred to work station (Advantage Windows) and data processing by Minimum Intensity Projection (Min...

  3. Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ho Gul; Kim, Kee Deog; Park, Hyok; Kim, Dong Ook; Jeong, Hai Jo; Kim, Hee Joung; Yoo, Sun Kook; Kim, Yong Oock; Park, Chang Seo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2004-07-15

    To evaluate the quantitative accuracy of three-dimensional (3D) images by mean of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0 (Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. 11 line items in Conventional 3 mm, 8 in Helical 3 mm, 11 in Conventional 5 mm, 10 in Helical 5 mm, 5 in Conventional 7 mm and 9 in Helical 7 mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2 mm in 19 line items of Conventional 3 mm. 20 of Helical 3 mm, 15 of Conventional 5 mm, 18 of Helical 5 mm, 11 of Conventional 7 mm and 16 of Helical 7 mm. Considering image quality and patient's exposure time, scanning protocol of Helical 5 mm is recommended for 3D image analysis of the skull in CT.

  4. Helical tomotherapy. Experiences of the first 150 patients in Heidelberg

    Energy Technology Data Exchange (ETDEWEB)

    Sterzing, F.; Schubert, K.; Sroka-Perez, G.; Kalz, J.; Debus, J.; Herfarth, K. [Dept. of Radiation Oncology, Univ. of Heidelberg (Germany)

    2008-01-15

    Background and purpose: helical tomotherapy was introduced into clinical routine at the Department of Radiation Oncology, University Hospital of Heidelberg, Germany, in July 2006. This report is intended to describe the experience with the first 150 patients treated with helical tomotherapy. Patient selection, time effort, handling of daily image guidance with megavoltage (MV) CT, and quality of radiation plans shall be assessed. Patients and methods: between July 2006 and May 2007, 150 patients were treated with helical tomotherapy in the University Hospital of Heidelberg. Mean age was 60 years with a minimum of 30 years and a maximum of 85 years. 79 of these patients received radiotherapy as a part of multimodal treatment pre- or postoperatively, 17 patients received treatment as a combined radiochemotherapy. 76% were treated with curative intent. Radiotherapy sites were central nervous system (n = 7), head and neck (n = 28), thoracic (n = 37), abdominal (n = 58) and skeletal system (n = 20). Most common tumor entities were prostate cancer (n = 28), breast cancer (n = 17), gastrointestinal tumors (n = 19), pharyngeal carcinoma (n = 14), lymphoma (n = 13), metastatic disease (bone n = 14, liver n = 6, lung n = 4, lymph node n = 2), sarcoma (n = 8), malignant pleural mesothelioma (n = 5), ovarian cancer treated with whole abdominal irradiation (n = 4), lung cancer (n = 3), skin malignancies (n = 3), chordoma (n = 2), meningioma (n = 2), one ependymoma and one medulloblastoma treated with craniospinal axis irradiation (n = 2), and others (n = 4). Nine patients were treated with single-fraction radiosurgery, nine with image-guided spinal reirradiation, and twelve patients were treated at multiple targets simultaneously. A pretreatment MV-CT scan was performed in 98.2% of the 3,026 fractions applied. After matching with the kilovoltage planning CT, corrections for translations and rotation around longitudinal axis (roll) were done. Results: mean time on table was 24

  5. Generalized helicity and Beltrami fields

    Energy Technology Data Exchange (ETDEWEB)

    Buniy, Roman V., E-mail: roman.buniy@gmail.com [Schmid College of Science, Chapman University, Orange, CA 92866 (United States); Isaac Newton Institute, University of Cambridge, Cambridge, CB3 0EH (United Kingdom); Kephart, Thomas W., E-mail: tom.kephart@gmail.com [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235 (United States); Isaac Newton Institute, University of Cambridge, Cambridge, CB3 0EH (United Kingdom)

    2014-05-15

    We propose covariant and non-abelian generalizations of the magnetic helicity and Beltrami equation. The gauge invariance, variational principle, conserved current, energy–momentum tensor and choice of boundary conditions elucidate the subject. In particular, we prove that any extremal of the Yang–Mills action functional 1/4 ∫{sub Ω}trF{sub μν}F{sup μν}d{sup 4}x subject to the local constraint ε{sup μναβ}trF{sub μν}F{sub αβ}=0 satisfies the covariant non-abelian Beltrami equation. -- Highlights: •We introduce the covariant non-abelian helicity and Beltrami equation. •The Yang–Mills action and instanton term constraint lead to the Beltrami equation. •Solutions of the Beltrami equation conserve helicity.

  6. Brownian motion of helical flagella.

    Science.gov (United States)

    Hoshikawa, H; Saito, N

    1979-07-01

    We develops a theory of the Brownian motion of a rigid helical object such as bacterial flagella. The statistical properties of the random forces acting on the helical object are discussed and the coefficients of the correlations of the random forces are determined. The averages , and are also calculated where z and theta are the position along and angle around the helix axis respectively. Although the theory is limited to short time interval, direct comparison with experiment is possible by using the recently developed cinematography technique.

  7. Optical and Infrared Helical Metamaterials

    Directory of Open Access Journals (Sweden)

    Kaschke Johannes

    2016-09-01

    Full Text Available By tailoring metamaterials with chiral unit cells, giant optical activity and strong circular dichroism have been achieved successfully over the past decade. Metamaterials based on arrays of metal helices have revolutionized the field of chiral metamaterials, because of their capability of exhibiting these pronounced chiro-optical effects over previously unmatched bandwidths. More recently, a large number of new metamaterial designs based on metal helices have been introduced with either optimized optical performance or other chiro-optical properties for novel applications.

  8. A hypothesis on neutrino helicity

    CERN Document Server

    Sahin, I

    2016-01-01

    It is firmly established by experimental results that neutrinos are almost 100\\% longitudinally polarized and left-handed. It is also confirmed by neutrino oscillation experiments that neutrinos have tiny but non-zero masses. Since the helicity is not a Lorentz invariant quantity for massive particles, neutrinos can not be strictly left-handed. On the other hand, it is generally assumed that ultrarelativistic massive fermions can be described well enough by the Weyl equations. We discuss the validity of this assumption and propose a new hypothesis according to which neutrinos can be described by pure helicity states although they are not massless.

  9. Magnetic Helicity Injection in Solar Active Regions

    Institute of Scientific and Technical Information of China (English)

    Hong-Qi Zhang

    2006-01-01

    We present the evolution of magnetic field and its relationship with magnetic (current) helicity in solar active regions from a series of photospheric vector magnetograms obtained by Huairou Solar Observing Station, longitudinal magnetograms by MDI of SOHO and white light images of TRACE. The photospheric current helicity density is a quantity reflecting the local twisted magnetic field and is related to the remaining magnetic helicity in the photosphere, even if the mean current helicity density brings the general chiral property in a layer of solar active regions. As new magnetic flux emerges in active regions, changes of photospheric current helicity density with the injection of magnetic helicity into the corona from the subatmosphere can be detected, including changes in sign caused by the injection of magnetic helicity of opposite sign. Because the injection rate of magnetic helicity and photospheric current helicity density have different means in the solar atmosphere,the injected magnetic helicity is probably not proportional to the current helicity density remaining in the photosphere. The evidence is that rotation of sunspots does not synchronize exactly with the twist of photospheric transverse magnetic field in some active regions (such as, delta active regions). They represent different aspects of magnetic chirality. A combined analysis of the observational magnetic helicity parameters actually provides a relative complete picture of magnetic helicity and its transfer in the solar atmosphere.

  10. Review of biphasic insulin aspart in the treatment of type 1 and 2 diabetes

    Directory of Open Access Journals (Sweden)

    Nazia Raja-Khan

    2008-01-01

    Full Text Available Nazia Raja-Khan, Sarah S Warehime, Robert A GabbayDivision of Endocrinology, Diabetes, and Metabolism, Penn State Institute for Diabetes and Obesity, Pennsylvania State University College of Medicine, Hershey, Pennsylvania, USABackground: Insulin is an effective treatment for achieving glycemic control and preventing complications in patients with diabetes. In order to make insulin therapy more acceptable to patients, newer formulations of insulin have been developed, such as biphasic insulins. Biphasic insulins conveniently provide both prandial and basal insulin in a single injection. One of the most well-studied biphasic insulins is biphasic insulin aspart 70/30.Objective: Our goal was to review the current literature on the safety and efficacy of biphasic insulin aspart in type 1 and type 2 diabetes.Methods: A MEDLINE search was conducted using the terms “biphasic insulin aspart” to identify clinical studies and reviews.Results: Biphasic insulin aspart more effectively reduces post-prandial glucose compared to other biphasic insulins and basal insulins. Compared to biphasic insulin aspart, fasting glucose levels are lower with NPH, similar with glargine, and similar or lower with biphasic human insulin. Treat-to-target trials have shown that a goal HbA1c below 6.5 or 7% can be achieved with biphasic insulin aspart. The risk of hypoglycemia is similar to or less than that seen with other biphasic insulins or NPH insulin.Conclusion: Biphasic insulin aspart 70/30 is a safe and effective treatment option for patients with diabetes.Keywords: biphasic insulin aspart, insulin, diabetes

  11. 20 percent lower lung cancer mortality with low-dose CT vs chest X-ray

    Science.gov (United States)

    Scientists have found a 20 percent reduction in deaths from lung cancer among current or former heavy smokers who were screened with low-dose helical computed tomography (CT) versus those screened by chest X-ray.

  12. Thermoreversible (Ionic-Liquid-Based) Aqueous Biphasic Systems.

    Science.gov (United States)

    Passos, Helena; Luís, Andreia; Coutinho, João A P; Freire, Mara G

    2016-02-04

    The ability to induce reversible phase transitions between homogeneous solutions and biphasic liquid-liquid systems, at pre-defined and suitable operating temperatures, is of crucial relevance in the design of separation processes. Ionic-liquid-based aqueous biphasic systems (IL-based ABS) have demonstrated superior performance as alternative extraction platforms, and their thermoreversible behaviour is here disclosed by the use of protic ILs. The applicability of the temperature-induced phase switching is further demonstrated with the complete extraction of two value-added proteins, achieved in a single-step. It is shown that these temperature-induced mono(bi)phasic systems are significantly more versatile than classical liquid-liquid systems which are constrained by their critical temperatures. IL-based ABS allow to work in a wide range of temperatures and compositions which can be tailored to fit the requirements of a given separation process.

  13. Head CT scan

    Science.gov (United States)

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... hold your breath for short periods. A complete scan usually take only 30 seconds to a few ...

  14. The Transport of Relative Canonical Helicity

    CERN Document Server

    You, Setthivoine

    2012-01-01

    The evolution of relative canonical helicity is examined in the two-fluid magnetohydrodynamic formalism. Canonical helicity is defined here as the helicity of the plasma species' canonical momentum. The species' canonical helicity are coupled together and can be converted from one into the other while the total gauge-invariant relative canonical helicity remains globally invariant. The conversion is driven by enthalpy differences at a surface common to ion and electron canonical flux tubes. The model provides an explanation for why the threshold for bifurcation in counter-helicity merging depends on the size parameter. The size parameter determines whether magnetic helicity annihilation channels enthalpy into the magnetic flux tube or into the vorticity flow tube components of the canonical flux tube. The transport of relative canonical helicity constrains the interaction between plasma flows and magnetic fields, and provides a more general framework for driving flows and currents from enthalpy or inductive b...

  15. Actinide recovery using aqueous biphasic extraction: Initial developmental studies

    Energy Technology Data Exchange (ETDEWEB)

    Chaiko, D.J.; Mensah-Biney, R.; Mertz, C.J.; Rollins, A.N.

    1992-08-01

    Aqueous biphasic extraction systems are being developed to treat radioactive wastes. The separation technique involves the selective partitioning of either solutes or colloid-size particles between two scible aqueous phases. Wet grinding of plutonium residues to an average particle size of one micron will be used to liberate the plutonium from the bulk of the particle matrix. The goal is to produce a plutonium concentrate that will integrate with existing and developing chemical recovery processes. Ideally, the process would produce a nonTRU waste stream. Coupling physical beneficiation with chemical processing will result in a substantial reduction in the volume of mixed wastes generated from dissolution recovery processes. As part of this program, we will also explore applications of aqueous biphasic extraction that include the separation and recovery of dissolved species such as metal ions and water-soluble organics. The expertise and data generated in this work will form the basis for developing more cost-effective processes for handling waste streams from environmental restoration and waste management activities within the DOE community. This report summarizes the experimental results obtained during the first year of this effort. Experimental efforts were focused on elucidating the surface and solution chemistry variables which govern partitioning behavior of plutonium and silica in aqueous biphasic extraction systems. Additional efforts were directed toward the development of wet grinding methods for producing ultrafine particles with diameters of one micron or less.

  16. Applications of 2D helical vortex dynamics

    DEFF Research Database (Denmark)

    Okulov, Valery; Sørensen, Jens Nørkær

    2010-01-01

    In the paper, we show how the assumption of helical symmetry in the context of 2D helical vortices can be exploited to analyse and to model various cases of rotating flows. From theory, examples of three basic applications of 2D dynamics of helical vortices embedded in flows with helical symmetry...... of the vorticity field are addressed. These included some of the problems related to vortex breakdown, instability of far wakes behind rotors and vortex theory of ideal rotors....

  17. Influence of Magnetic Helicity in MHD

    CERN Document Server

    Candelaresi, Simon; Brandenburg, Axel

    2010-01-01

    Observations have shown that the Sun's magnetic field has helical structures. The helicity content in magnetic field configurations is a crucial constraint on the dynamical evolution of the system. Since helicity is connected with the number of links we investigate configurations with interlocked magnetic flux rings and one with unlinked rings. It turns out that it is not the linking of the tubes which affects the magnetic field decay, but the content of magnetic helicity.

  18. On the triple correlations in helical turbulence

    CERN Document Server

    Chkhetiani, O

    1997-01-01

    The evolution of correlation characteristics in homogeneous helical turbulence is considered. Additional K'arm'an-Howarth type equations, describing the evolution of the mixed correlation tensor of the velocity and vorticity are obtained. In the helical scaling region, the solution of obtained equation gives the exact relation between antisymmetric component of a rank-three tensor and the average dissipation of helicity. This relation is a helical analogue of Kolmogorov's known 4/5 law.

  19. Standardized CT examination of the multitraumatized patient

    Energy Technology Data Exchange (ETDEWEB)

    Leidner, B. [Department of Diagnostic Radiology, Oskarshamn Hospital (Sweden)]|[Department of Diagnostic Radiology, Huddinge University Hospital (Sweden); Adiels, M. [Department of Diagnostic Radiology, Oskarshamn Hospital (Sweden); Aspelin, P. [Department of Diagnostic Radiology, Huddinge University Hospital (Sweden); Gullstrand, P.; Wallen, S. [Department of Surgery, Oskarshamn Hospital (Sweden)

    1998-12-01

    The aim of this study was to develop a standardized non-helical-CT protocol including head, body and proximal extremities in order to achieve a good time efficiency and diagnostic accuracy in the initial radiological evaluation of the multitraumatized patient. A total of 111 circulatory stable blunt trauma patients, brought in to a trauma level II-III hospital, were examined according to a standardized CT protocol. After examining the head with contiguous 10-mm slices without IV contrast medium injection, the trunk was examined with 10-mm slices every 30 mm through thorax-abdomen-pelvis with IV contrast medium enhancement (occasionally modified). All data in the medical reports were collected and used as ``end-point``, and the outcome of the CT examination was compared with this final diagnosis. Mean examination time was 20 min (range 12-32 min). In total, 55 head injuries, 89 thoracic injuries, 27 abdominal/pelvic injuries and 62 fractures were found. Computed tomography correctly identified the injuries, except one brain stem injury, one contusion/rupture of the heart, one hepatic injury, two intestinal injuries, eight vertebral injuries and one joint dislocation. A standardized non-helical-CT examination of the head and body may be achieved in 20 min. Its diagnostic accuracy was high, except for vertebral column injuries, which is why we recommend it as the method of choice for initial radiological examination of multitraumatized patients. When available, helical scanning would improve both examination speed and accuracy. (orig.) With 6 figs., 40 refs.

  20. Experience with volumetric (320 rows) pediatric CT

    Energy Technology Data Exchange (ETDEWEB)

    Sorantin, E., E-mail: erich.sorantin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, Medical University Graz (Austria); Riccabona, M. [Division of Pediatric Radiology, Department of Radiology, Medical University Graz (Austria); Stücklschweiger, G.; Guss, H. [Competence Centre for Medical Physics and Radiation Protection, Univ.-Hospital Graz (Austria); Fotter, R. [Division of Pediatric Radiology, Department of Radiology, Medical University Graz (Austria)

    2013-07-15

    The introduction of helical computer tomography (CT) and further progress to multi-slice CT enabled new applications. Most recent developments like the 320-row detector facilitate volume CT, which avoids the over-beaming effect of helical scanning. The 320-row multi-slice detector CT (MDCT) is based on a 16 cm detector; a special acquisition mode allows reconstructing 640 slices from these 16 cm. The shortest tube rotation time is in cardiac mode 0.35 s, otherwise 0.4 s and 0.5 s used. At 0.5 s the machine already reaches the maximum numbers of sub-second projections. Scan modes can be volume, helical and single slice mode. For image acquisition all dose savings technologies like variable tube position for scano-view, active collimation, automated exposure control, bolus and ECG tracking are available. Additionally special acquisition and post-processing techniques like head and body perfusion CT are ready for use on the console. For image reconstruction properties like filtered back projection as well as the latest development of iterative algorithms, an appropriate number of kernels and multi-planar reconstruction in all directions from the volume data at every increment are available. Volume CT allows sub second scanning of 16 cm z-coverage which, however, makes administration of intravenous contrast medium to “hit or miss” event. The aim of this paper is to present the application of volume CT to body scanning in children. Representative examples of neck, cardiac and skeletal investigations are given.

  1. Hybrid helical snakes and rotators for RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Courant, E.D.

    1995-06-13

    The spin rotators and Siberian snakes presently envisaged for RHIC utilize helical dipole magnets. The snakes and the rotators each consist of four helices, each with a full twist (360{degrees}) of the field. Here we investigate an alternate layout, namely combinations of helical and pure bending magnet, and show that this may have advantages.

  2. Enantiomeric differentiation by synthetic helical polymers.

    Science.gov (United States)

    Yashima, Eiji; Iida, Hiroki; Okamoto, Yoshio

    2013-01-01

    Recent advances in the synthesis of helical polymers and their applications as chiral materials, in particular chiral stationary phases (CSPs), for high-performance liquid chromatography (HPLC) are reviewed with an emphasis on the key role of the helical conformations with one-handedness for the prominent chiral recognition of enantiomers. The historical background of artificial optically active helical polymers is also briefly described.

  3. CT in vascular pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Bartolozzi, C.; Neri, E.; Caramella, D. [Diagnostic and Interventional Radiology Department of Oncology, University of Pisa, Via Roma 67, I-56100 Pisa (Italy)

    1998-06-02

    Since the introduction of helical scanners, CT angiography (CTA) has achieved an essential role in many vascular applications that were previously managed with conventional angiography. The performance of CTA is based on the accurate selection of collimation width, pitch, reconstruction spacing and scan delay, which must be modulated on the basis of the clinical issue. However, the major improvement of CT has been provided by the recent implementation of many post-processing techniques, such as multiplanar reformatting, shaded surface display, maximum intensity projections, 3D perspectives of surface and volume rendering, which simulate virtual intravascular endoscopy. The integration of the potentialities of the scanner and of the image processing techniques permitted improvement of: (a) the evaluation of aneurysms, dissection and vascular anomalies involving the thoracic aorta; (b) carotid artery stenosis; (c) aneurysms of abdominal aorta; (d) renal artery stenosis; (e) follow-up of renal artery stenting; and (f) acute or chronic pulmonary embolism. Our experience has shown that the assessment of arterial pathologies with CTA requires the integration of 3D post-processing techniques in most applications. (orig.) With 4 figs., 34 refs.

  4. Performance tests on helical Savonius rotors

    Energy Technology Data Exchange (ETDEWEB)

    Kamoji, M.A.; Kedare, S.B. [Department of Energy Science and Engineering, Indian Institute of Technology, Bombay (India); Prabhu, S.V. [Department of Mechanical Engineering, Indian Institute of Technology, Bombay (India)

    2009-03-15

    Conventional Savonius rotors have high coefficient of static torque at certain rotor angles and a negative coefficient of static torque from 135 to 165 and from 315 to 345 in one cycle of 360 . In order to decrease this variation in static torque from 0 to 360 , a helical Savonius rotor with a twist of 90 is proposed. In this study, tests on helical Savonius rotors are conducted in an open jet wind tunnel. Coefficient of static torque, coefficient of torque and coefficient of power for each helical Savonius rotor are measured. The performance of helical rotor with shaft between the end plates and helical rotor without shaft between the end plates at different overlap ratios namely 0.0, 0.1 and 0.16 is compared. Helical Savonius rotor without shaft is also compared with the performance of the conventional Savonius rotor. The results indicate that all the helical Savonius rotors have positive coefficient of static torque at all the rotor angles. The helical rotors with shaft have lower coefficient of power than the helical rotors without shaft. Helical rotor without shaft at an overlap ratio of 0.0 and an aspect ratio of 0.88 is found to have almost the same coefficient of power when compared with the conventional Savonius rotor. Correlation for coefficient of torque and power is developed for helical Savonius rotor for a range of Reynolds numbers studied. (author)

  5. Predictive supracolloidal helices from patchy particles

    Science.gov (United States)

    Guo, Ruohai; Mao, Jian; Xie, Xu-Ming; Yan, Li-Tang

    2014-11-01

    A priori prediction of supracolloidal architectures from nanoparticle and colloidal assembly is a challenging goal in materials chemistry and physics. Despite intense research in this area, much less has been known about the predictive science of supracolloidal helices from designed building blocks. Therefore, developing conceptually new rules to construct supracolloidal architectures with predictive helicity is becoming an important and urgent task of great scientific interest. Here, inspired by biological helices, we show that the rational design of patchy arrangement and interaction can drive patchy particles to self-assemble into biomolecular mimetic supracolloidal helices. We further derive a facile design rule for encoding the target supracolloidal helices, thus opening the doors to the predictive science of these supracolloidal architectures. It is also found that kinetics and reaction pathway during the formation of supracolloidal helices offer a unique way to study supramolecular polymerization, and that well-controlled supracolloidal helices can exhibit tailorable circular dichroism effects at visible wavelengths.

  6. A helical scintillating fiber hodoscope

    CERN Document Server

    Altmeier, M; Bisplinghoff, J; Bissel, T; Bollmann, R; Busch, M; Büsser, K; Colberg, T; Demiroers, L; Diehl, O; Dohrmann, F; Engelhardt, H P; Eversheim, P D; Felden, O; Gebel, R; Glende, M; Greiff, J; Gross, A; Gross-Hardt, R; Hinterberger, F; Jahn, R; Jeske, M; Jonas, E; Krause, H; Lahr, U; Langkau, R; Lindemann, T; Lindlein, J; Maier, R; Maschuw, R; Mayer-Kuckuck, T; Meinerzhagen, A; Naehle, O; Pfuff, M; Prasuhn, D; Rohdjess, H; Rosendaal, D; Von Rossen, P; Sanz, B; Schirm, N; Schulz-Rojahn, M; Schwarz, V; Scobel, W; Thomas, S; Trelle, H J; Weise, E; Wellinghausen, A; Wiedmann, W; Woller, K; Ziegler, R

    1999-01-01

    A novel scintillating fiber hodoscope in helically cylindric geometry has been developed for detection of low multiplicity events of fast protons and other light charged particles in the internal target experiment EDDA at the Cooler Synchrotron COSY. The hodoscope consists of 640 scintillating fibers (2.5 mm diameter), arranged in four layers surrounding the COSY beam pipe. The fibers are helically wound in opposing directions and read out individually using 16-channel photomultipliers connected to a modified commercial encoding system. The detector covers an angular range of 9 deg. <= THETA<=72 deg. and 0 deg. <=phi (cursive,open) Greek<=360 deg. in the lab frame. The detector length is 590 mm, the inner diameter 161 mm. Geometry and granularity of the hodoscope afford a position resolution of about 1.3 mm. The detector design took into consideration a maximum of reliability and a minimum of maintenance. An LED array may be used for monitoring purposes. (author)

  7. A helical scintillating fiber hodoscope

    Energy Technology Data Exchange (ETDEWEB)

    Altmeier, M.; Bauer, F.; Bisplinghoff, J.; Bissel, T.; Bollmann, R.; Busch, M.; Buesser, K.; Colberg, T.; Demiroers, L.; Diehl, O.; Dohrmann, F.; Engelhardt, H.P.; Eversheim, P.D.; Felden, O.; Gebel, R.; Glende, M.; Greiff, J.; Gross, A.; Gross-Hardt, R.; Hinterberger, F.; Jahn, R.; Jeske, M.; Jonas, E.; Krause, H.; Lahr, U.; Langkau, R.; Lindemann, T.; Lindlein, J.; Maier, R.; Maschuw, R.; Mayer-Kuckuck, T.; Meinerzhagen, A.; Naehle, O.; Pfuff, M.; Prasuhn, D.; Rohdjess, H.; Rosendaal, D.; Rossen, P. von; Sanz, B.; Schirm, N.; Schulz-Rojahn, M.; Schwarz, V.; Scobel, W.; Thomas, S.; Trelle, H.J.; Weise, E.; Wellinghausen, A.; Wiedmann, W.; Woller, K.; Ziegler, R

    1999-07-21

    A novel scintillating fiber hodoscope in helically cylindric geometry has been developed for detection of low multiplicity events of fast protons and other light charged particles in the internal target experiment EDDA at the Cooler Synchrotron COSY. The hodoscope consists of 640 scintillating fibers (2.5 mm diameter), arranged in four layers surrounding the COSY beam pipe. The fibers are helically wound in opposing directions and read out individually using 16-channel photomultipliers connected to a modified commercial encoding system. The detector covers an angular range of 9 deg. {<=}{theta}{<=}72 deg. and 0 deg. {<=}phi (cursive,open) Greek{<=}360 deg. in the lab frame. The detector length is 590 mm, the inner diameter 161 mm. Geometry and granularity of the hodoscope afford a position resolution of about 1.3 mm. The detector design took into consideration a maximum of reliability and a minimum of maintenance. An LED array may be used for monitoring purposes. (author)

  8. Adjustable phase planar helical undulator

    Science.gov (United States)

    Carr, Roger G.; Lidia, Steve

    1993-11-01

    We present here the design description of a new type of planar helical undulator, which we are constructing for the SPEAR storage ring at the Stanford Synchrotron Radiation Laboratory. It comprises four rows of pure permanent magnet blocks, one row in each quadrant about the axis defined by the electron beam. Rows may be translated longitudinally with respect to each other to change the helicity of the magnetic field they create at the position of the beam. They may also be translated longitudinally to vary the energy of the x-rays emitted, unlike designs where this function is performed by varying the gap between the rows. This work includes numerical calculations of the fields, electron trajectories, and x-ray spectra, including off-axis effects.

  9. An experimental superconducting helical undulator

    Energy Technology Data Exchange (ETDEWEB)

    Caspi, S.; Taylor, C. [Lawrence Berkeley Lab., CA (United States)

    1995-12-31

    Improvements in the technology of superconducting magnets for high energy physics and recent advancements in SC materials with the artificial pinning centers (APC){sup 2}, have made a bifilar helical SC device an attractive candidate for a single-pass free electron laser (FEL){sup 3}. Initial studies have suggested that a 6.5 mm inner diameter helical device, with a 27 mm period, can generate a central field of 2-2.5 Tesla. Additional studies have also suggested that with a stored energy of 300 J/m, such a device can be made self-protecting in the event of a quench. However, since the most critical area associated with high current density SC magnets is connected with quenching and training, a short experimental device will have to be built and tested. In this paper we discuss technical issues relevant to the construction of such a device, including a conceptual design, fields, and forces.

  10. A case of dedifferentiated liposarcoma showing a biphasic pattern on 2-deoxy-2-F18- fluoro-D-glucose positron emission tomography/ computed tomography

    Directory of Open Access Journals (Sweden)

    Manabu Hoshi

    2013-04-01

    Full Text Available Integrated 2-deoxy-2-F18-fluoro-D-glucose positron emission tomography combined with computed tomography (FDG-PET/CT has been used in the field of soft tissue sarcoma. We report an 81-year-old man with dedifferentiated liposarcoma in the left thigh, which was composed of well-differentiated liposarcoma and pleomorphic malignant fibrous histiocytoma. As well as other radiological modalities, FDG-PET was able to demonstrate a biphasic signal pattern composed of well-differentiated liposarcoma and dedifferentiated area, being consistent with the histological grade of malignancy.

  11. Emulsification-Induced Homohelicity in Racemic Helical Polymer for Preparing Optically Active Helical Polymer Nanoparticles.

    Science.gov (United States)

    Zhao, Biao; Deng, Jinrui; Deng, Jianping

    2016-04-01

    Optically active nano- and microparticles have constituted a significant category of advanced functional materials. However, constructing optically active particles derived from synthetic helical polymers still remains as a big challenge. In the present study, it is attempted to induce a racemic helical polymer (containing right- and left-handed helices in equal amount) to prefer one predominant helicity in aqueous media by using emulsifier in the presence of chiral additive (emulsification process). Excitingly, the emulsification process promotes the racemic helical polymer to unify the helicity and directly provides optically active nanoparticles constructed by chirally helical polymer. A possible mechanism is proposed to explain the emulsification-induced homohelicity effect. The present study establishes a novel strategy for preparing chirally helical polymer-derived optically active nanoparticles based on racemic helical polymers.

  12. Biphasic Insulin Analogues in Type 2 Diabetes: Expert Panel Recommendations

    Directory of Open Access Journals (Sweden)

    Sema Akalın

    2011-09-01

    Full Text Available Recently, the prevalence of type 2 diabetes has reached pandemic levels all over the world, and the problem is still growing. Type 2 diabetes is a progressive disease, in which insulin resistance and decrease in beta cell function accompany obesity. Early disorder, which ensues in clinical progression of the disease, is the defect of early phase insulin secretion. Patients have already lost approximately half of their beta cell reserve at the time of diagnosis. Aims of type 2 diabetes treatment are to eliminate hyperglycemia caused by insufficient insulin secretion and/or insulin resistance, to slow down beta cell destruction/depletion, to improve concomitant metabolic problems and to prevent complications. In treatment algorithms, insulin is evaluated as a replacement therapy at the following stage after life style changes (medical nutrition therapy, exercise and oral anti-diabetic drugs (OADs options. Since beta cell depletion is present at initial stages of the disease, it transforms insulin therapy into an earlier approach in treatment stages. Premixed insulin forms are one of the proposed treatment options in patients with hyperglycemia that is not controlled by OADs. These types of insulins are developed to meet both basal and postprandial insulin requirements of patients. Currently, premixed human insulin forms are replaced by analogue insulin forms, which can mimic the physiological secretion in more acceptable manner. Biphasic analogue insulin is one of the readily available pre-mixed analogue insulin forms, an example of this, Biphasic Insulin aspart 30 which is the one of the premixed analoge insulin forms, contains 30% insulin aspart and 70% protaminated insulin aspart. Consensus recommending the individualized approach in insulin therapy implies that physicians should have more detailed information about the use of different insulin forms. Although a global consensus report about initiation, titration and intensification and the use

  13. Helical Antimicrobial Sulfono- {gamma} -AApeptides

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yaqiong; Wu, Haifan; Teng, Peng; Bai, Ge; Lin, Xiaoyang; Zuo, Xiaobing; Cao, Chuanhai; Cai, Jianfeng

    2015-06-11

    Host-defense peptides (HDPs) such as magainin 2 have emerged as potential therapeutic agents combating antibiotic resistance. Inspired by their structures and mechanism of action, herein we report the fi rst example of antimicrobial helical sulfono- γ - AApeptide foldamers. The lead molecule displays broad-spectrum and potent antimicrobial activity against multi-drug-resistant Gram- positive and Gram-negative bacterial pathogens. Time-kill studies and fl uorescence microscopy suggest that sulfono- γ -AApeptides eradicate bacteria by taking a mode of action analogous to that of HDPs. Clear structure - function relationships exist in the studied sequences. Longer sequences, presumably adopting more-de fi ned helical structures, are more potent than shorter ones. Interestingly, the sequence with less helical propensity in solution could be more selective than the stronger helix-forming sequences. Moreover, this class of antimicrobial agents are resistant to proteolytic degradation. These results may lead to the development of a new class of antimicrobial foldamers combating emerging antibiotic-resistant pathogens.

  14. Helically twisted photonic crystal fibres.

    Science.gov (United States)

    Russell, P St J; Beravat, R; Wong, G K L

    2017-02-28

    Recent theoretical and experimental work on helically twisted photonic crystal fibres (PCFs) is reviewed. Helical Bloch theory is introduced, including a new formalism based on the tight-binding approximation. It is used to explore and explain a variety of unusual effects that appear in a range of different twisted PCFs, including fibres with a single core and fibres with N cores arranged in a ring around the fibre axis. We discuss a new kind of birefringence that causes the propagation constants of left- and right-spinning optical vortices to be non-degenerate for the same order of orbital angular momentum (OAM). Topological effects, arising from the twisted periodic 'space', cause light to spiral around the fibre axis, with fascinating consequences, including the appearance of dips in the transmission spectrum and low loss guidance in coreless PCF. Discussing twisted fibres with a single off-axis core, we report that optical activity in a PCF is opposite in sign to that seen in a step-index fibre. Fabrication techniques are briefly described and emerging applications reviewed. The analytical results of helical Bloch theory are verified by an extensive series of 'numerical experiments' based on finite-element solutions of Maxwell's equations in a helicoidal frame.This article is part of the themed issue 'Optical orbital angular momentum'. © 2017 The Authors.

  15. Helically twisted photonic crystal fibres

    Science.gov (United States)

    Russell, P. St. J.; Beravat, R.; Wong, G. K. L.

    2017-02-01

    Recent theoretical and experimental work on helically twisted photonic crystal fibres (PCFs) is reviewed. Helical Bloch theory is introduced, including a new formalism based on the tight-binding approximation. It is used to explore and explain a variety of unusual effects that appear in a range of different twisted PCFs, including fibres with a single core and fibres with N cores arranged in a ring around the fibre axis. We discuss a new kind of birefringence that causes the propagation constants of left- and right-spinning optical vortices to be non-degenerate for the same order of orbital angular momentum (OAM). Topological effects, arising from the twisted periodic `space', cause light to spiral around the fibre axis, with fascinating consequences, including the appearance of dips in the transmission spectrum and low loss guidance in coreless PCF. Discussing twisted fibres with a single off-axis core, we report that optical activity in a PCF is opposite in sign to that seen in a step-index fibre. Fabrication techniques are briefly described and emerging applications reviewed. The analytical results of helical Bloch theory are verified by an extensive series of `numerical experiments' based on finite-element solutions of Maxwell's equations in a helicoidal frame. This article is part of the themed issue 'Optical orbital angular momentum'.

  16. Helically twisted photonic crystal fibres

    Science.gov (United States)

    Beravat, R.; Wong, G. K. L.

    2017-01-01

    Recent theoretical and experimental work on helically twisted photonic crystal fibres (PCFs) is reviewed. Helical Bloch theory is introduced, including a new formalism based on the tight-binding approximation. It is used to explore and explain a variety of unusual effects that appear in a range of different twisted PCFs, including fibres with a single core and fibres with N cores arranged in a ring around the fibre axis. We discuss a new kind of birefringence that causes the propagation constants of left- and right-spinning optical vortices to be non-degenerate for the same order of orbital angular momentum (OAM). Topological effects, arising from the twisted periodic ‘space’, cause light to spiral around the fibre axis, with fascinating consequences, including the appearance of dips in the transmission spectrum and low loss guidance in coreless PCF. Discussing twisted fibres with a single off-axis core, we report that optical activity in a PCF is opposite in sign to that seen in a step-index fibre. Fabrication techniques are briefly described and emerging applications reviewed. The analytical results of helical Bloch theory are verified by an extensive series of ‘numerical experiments’ based on finite-element solutions of Maxwell's equations in a helicoidal frame. This article is part of the themed issue ‘Optical orbital angular momentum’. PMID:28069771

  17. The Streptococcus pneumoniae pilus-1 displays a biphasic expression pattern.

    Directory of Open Access Journals (Sweden)

    Gabriella De Angelis

    Full Text Available The Streptococcus pneumoniae pilus-1 is encoded by pilus islet 1 (PI-1, which has three clonal variants (clade I, II and III and is present in about 30% of clinical pneumococcal isolates. In vitro and in vivo assays have demonstrated that pilus-1 is involved in attachment to epithelial cells and virulence, as well as protection in mouse models of infection. Several reports suggest that pilus-1 expression is tightly regulated and involves the interplay of numerous genetic regulators, including the PI-1 positive regulator RlrA. In this report we provide evidence that pilus expression, when analyzed at the single-cell level in PI-1 positive strains, is biphasic. In fact, the strains present two phenotypically different sub-populations of bacteria, one that expresses the pilus, while the other does not. The proportions of these two phenotypes are variable among the strains tested and are not influenced by genotype, serotype, growth conditions, colony morphology or by the presence of antibodies directed toward the pilus components. Two sub-populations, enriched in pilus expressing or not expressing bacteria were obtained by means of colony selection and immuno-detection methods for five strains. PI-1 sequencing in the two sub-populations revealed the absence of mutations, thus indicating that the biphasic expression observed is not due to a genetic modification within PI-1. Microarray expression profile and western blot analyses on whole bacterial lysates performed comparing the two enriched sub-populations, revealed that pilus expression is regulated at the transcriptional level (on/off regulation, and that there are no other genes, in addition to those encoded by PI-1, concurrently regulated across the strains tested. Finally, we provide evidence that the over-expression of the RrlA positive regulator is sufficient to induce pilus expression in pilus-1 negative bacteria. Overall, the data presented here suggest that the observed biphasic pilus

  18. A new kinetic biphasic approach applied to biodiesel process intensification

    Energy Technology Data Exchange (ETDEWEB)

    Russo, V.; Tesser, R.; Di Serio, M.; Santacesaria, E. [Naples Univ. (Italy). Dept. of Chemistry

    2012-07-01

    Many different papers have been published on the kinetics of the transesterification of vegetable oil with methanol, in the presence of alkaline catalysts to produce biodiesel. All the proposed approaches are based on the assumption of a pseudo-monophasic system. The consequence of these approaches is that some experimental aspects cannot be described. For the reaction performed in batch conditions, for example, the monophasic approach is not able to reproduce the different plateau obtained by using different amount of catalyst or the induction time observed at low stirring rates. Moreover, it has been observed by operating in continuous reactors that micromixing has a dramatic effect on the reaction rate. At this purpose, we have recently observed that is possible to obtain a complete conversion to biodiesel in less than 10 seconds of reaction time. This observation is confirmed also by other authors using different types of reactors like: static mixers, micro-reactors, oscillatory flow reactors, cavitational reactors, microwave reactors or centrifugal contactors. In this work we will show that a recently proposed biphasic kinetic approach is able to describe all the aspects before mentioned that cannot be described by the monophasic kinetic model. In particular, we will show that the biphasic kinetic model can describe both the induction time observed in the batch reactors, at low stirring rate, and the very high conversions obtainable in a micro-channel reactor. The adopted biphasic kinetic model is based on a reliable reaction mechanism that will be validated by the experimental evidences reported in this work. (orig.)

  19. HAp granules encapsulated oxidized alginate-gelatin-biphasic calcium phosphate hydrogel for bone regeneration.

    Science.gov (United States)

    Sarker, Avik; Amirian, Jhaleh; Min, Young Ki; Lee, Byong Taek

    2015-11-01

    Bone repair in the critical size defect zone using 3D hydrogel scaffold is still a challenge in tissue engineering field. A novel type of hydrogel scaffold combining ceramic and polymer materials, therefore, was fabricated to meet this challenge. In this study, oxidized alginate-gelatin-biphasic calcium phosphate (OxAlg-Gel-BCP) and spherical hydroxyapatite (HAp) granules encapsulated OxAlg-Gel-BCP hydrogel complex were fabricated using freeze-drying method. Detailed morphological and material characterizations of OxAlg-Gel-BCP hydrogel (OGB00), 25wt% and 35wt% granules encapsulated hydrogel (OGB25 and OGB35) were carried out for micro-structure, porosity, chemical constituents, and compressive stress analysis. Cell viability, cell attachment, proliferation and differentiation behavior of rat bone marrow-derived stem cell (BMSC) on OGB00, OGB25 and OGB35 scaffolds were confirmed by MTT assay, Live-Dead assay, and confocal imaging in vitro experiments. Finally, OGB00 and OGB25 hydrogel scaffolds were implanted in the critical size defect of rabbit femoral chondyle for 4 and 8 weeks. The micro-CT analysis and histological studies conducted by H&E and Masson's trichrome demonstrated that a significantly higher (***phydrogel than in OxAlg-Gel-BCP complex alone. All results taken together, HAp granules encapsulated OxAlg-Gel-BCP system can be a promising 3D hydrogel scaffold for the healing of a critical bone defect.

  20. Biphasic enantioselective olefin epoxidation using Tropos dibenzoazepinium catalysts.

    Science.gov (United States)

    Vachon, Jérôme; Pérollier, Céline; Monchaud, David; Marsol, Claire; Ditrich, Klaus; Lacour, Jérôme

    2005-07-22

    Several novel chiral iminium TRISPHAT [tris(tetrachlorobenzenediolato)phosphate(V)] salts combining a diphenylazepinium core, chiral exocyclic appendages, and lipophilic counterions have been prepared and tested in biphasic enantioselective olefin epoxidation conditions. Interestingly, the iminium salts derived from commercially available (S)- or (R)-1,2,2-trimethylpropylamine can display efficiency similar to those made from L-acetonamine. Variable-temperature NMR spectroscopy (VT-NMR) and circular dichroism (CD) experiments were performed in search of a correlation between good enantioselectivity in the products and high diastereomeric control of the biphenyl axial chirality of the catalysts.

  1. 高清CT容积螺旋穿梭技术在儿童法洛四联症临床路径中的价值%The value of volume helical shuttle of high-definition CT in clinical path of tetralogy of Fallot in children

    Institute of Scientific and Technical Information of China (English)

    徐冬生; 孙凤伟; 范丽娟; 张立仁; 李旭; 杨丕丕

    2013-01-01

    目的 研究高清CT(HDCT)容积螺旋穿梭技术(VHS)对儿童法洛四联症(TOF)的诊断能力及其在临床路径中的价值.方法 88例术前行HDCT VHS扫描及超声心动图(ECHO)检查诊断为TOF的学龄前儿童,男51例,女37例,年龄1个月~10岁,中位年龄1岁.60例经手术证实,对比分析HDCT VHS与ECHO对TOF基本畸形,血流动力学及其他心内、外病变的显示能力,计算HDCT辐射剂量(mSv).结果 室间隔缺损(VSD)位置,HDCT诊断符合率95.0% (57/60),ECHO诊断符合率90.0% (54/60);测量VSD大小,HDCT数值小于ECHO,P<0.05,差异有统计学意义.判断TOF畸形VSD血流方向时,HDCT均显示VSD右向左分流,符合率100%(60/60),15例同时显示左向右分流,而ECHO均显示双向低速分流.右心室心肌肥厚性狭窄、流出道狭窄、肺动脉瓣狭窄畸形共99处,HDCT、ECHO与手术三者基本一致.McGoon比值,HDCT测量值大于ECHO,P<0.01,差异有统计学意义.主动脉骑跨畸形,HDCT与ECHO骑跨程度符合率均为98.3% (59/60),各误诊1例.其他心内畸形,如房间隔缺损、卵圆孔未闭等共37处,VHS漏诊25处,ECHO漏诊8处.其他心外畸形如一侧肺动脉的狭窄或闭锁、体-肺侧支血管、冠状动脉异常及动脉导管未闭等共88处,HDCT诊断符合率98.8% (87/88),ECHO诊断符合率59.1%(52/88).HDCT平均有效剂量为(1.58±0.43)mSv.结论 HDCT VHS诊断TOF有明显的优势,多组扫描数据能准确、直观地反映心内、外解剖畸形,辐射剂量在可接受的范围内.HDCT VHS与ECHO结合可作为儿童TOF术前确诊与鉴别诊断以及制定手术方案的临床路径.%Objective To discuss the value of volume helical shuttle(VHS) of high-definition CT(HDCT) in diagnosis and clinical path of tetralogy of Fallot(TOF).Methods 88 preschool children with TOF were examined with VHS of HDCT and echocardiography(ECHO).60 children were received surgery.Based on surgical data,the results of VHS of HDCT were compared with

  2. Combined PET/CT in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Keon Wook [National Cancer Center, Goyang (Korea, Republic of)

    2002-02-01

    Presently, PET is widely used in oncology, but suffers from limitations of poor anatomical information. To compensate for this weakness, a combined PET/CT has been developed by Professor Townsend at the University of Pittsburgh Medical Center. The prototype was designed as PET and CT components combined serially in a gantry. The CT images provide not only accurate anatomical location of the lesions but also transmission map for attenuation correction. More than 300 cancer patients have been studied with the prototype of PET/CT since July, 1998. The PET/TC studies affected the managements in about 20{approx}30% of cancer patients. These changes are a consequence of the more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake. Now a variety of combined PET/CT scanners with high-end PET and high-end CT components are commercially available. With the high speed of multi-slice helical CT, throughput of patient's increases compared to conventional PET. Although some problems (such as a discrepancy in breathing state between the two modalities) still remain, the role of PET/CT in oncology is very promising.

  3. The Study of Relationship between Inferior Phrenic Artery Originated from Abdominal Aorta and Celiac Trunk by Using Multi-Slice Helical CT%起源于腹主动脉的膈下动脉与腹腔干关系的多层螺旋CT研究

    Institute of Scientific and Technical Information of China (English)

    宫凤玲; 于鹏; 张惠英; 李盖; 赵鹤亮; 孙凤涛

    2011-01-01

    Purpose To explore whether there are some rules in the relationship between inferior phrenic artery (IPA) originated from the abdominal aorta and the celiac trunk. Materials and Methods The origin of IPA in 200 patients (174 with abdomen scan and 26 with chest-abdomen scan) who underwent two-phase enhanced CT scan at Philips 256-slice helical CT were respectively observed. The relationship of the orifice position between IPA originated from the abdominal aorta and the celiac trunk was analysed. Results RIPA was shown in 200 cases with total 201 branches. LIPA was shown in 198 cases with total 203 branches. 2 cases of LIPA were not shown. Bilateral IPA originated from a common stem was seen in 48 of 200 cases (24%). RIPA originated from the celiac trunk in 70/201 cases(34.8%) , from the aorta in 82/201 cases(40.8%), from the right renal artery in 37/201cases (18.4%), from the right accessory renal artery in 4/201cases (2.0%) and from the lefi gastric artery in 8/201 cases (4%). LIPA originated from the celiac trunk in 113/203 cases (55.7%), from the aorta in 77/203 cases (37.g%), from the left gastric artery in 11/203 cases(5.4%) and from the spleen artery in 2/203 cases (1.0%). There are some rules in the relationship between the origin of IPA originated from the abdominal aorta (135cases) and the celiac trunk: ① 98.3% of RIPA located in the 9-12 o'clock position relative to the wall of the aorta. LIPA and IPA which originated from a common stem located in the 12-3 o'clock position relative to the wall of aorta ; ② 80.0% of IPA had orifice located 10mm upper or lower of the orifice of the celiac trunk and the remaining located 10mm lower than the orifice of the celiac trunk.③ 63.8% of RIPA had the orifice located under the orifice of the celiac trunk. 43.4% of LIPA and 54.2% of IPA which originated from a common stem located upper than the orifice of the celiac trunk. ④ 86.8% of IPA had the orifice located under the orifice

  4. Cell-material interactions on biphasic polyurethane matrix.

    Science.gov (United States)

    Dicesare, Patrick; Fox, Wade M; Hill, Michael J; Krishnan, G Rajesh; Yang, Shuying; Sarkar, Debanjan

    2013-08-01

    Cell-matrix interaction is a key regulator for controlling stem cell fate in regenerative tissue engineering. These interactions are induced and controlled by the nanoscale features of extracellular matrix and are mimicked on synthetic matrices to control cell structure and functions. Recent studies have shown that nanostructured matrices can modulate stem cell behavior and exert specific role in tissue regeneration. In this study, we have demonstrated that nanostructured phase morphology of synthetic matrix can control adhesion, proliferation, organization and migration of human mesenchymal stem cells (MSCs). Nanostructured biodegradable polyurethanes (PU) with segmental composition exhibit biphasic morphology at nanoscale dimensions and can control cellular features of MSCs. Biodegradable PU with polyester soft segment and hard segment composed of aliphatic diisocyanates and dipeptide chain extender were designed to examine the effect polyurethane phase morphology. By altering the polyurethane composition, morphological architecture of PU was modulated and its effect was examined on MSC. Results show that MSCs can sense the nanoscale morphology of biphasic polyurethane matrix to exhibit distinct cellular features and, thus, signifies the relevance of matrix phase morphology. The role of nanostructured phases of a synthetic matrix in controlling cell-matrix interaction provides important insights for regulation of cell behavior on synthetic matrix and, therefore, is an important tool for engineering tissue regeneration. Copyright © 2012 Wiley Periodicals, Inc.

  5. Development and Characterization of Biphasic Hydroxyapatite/β-TCP Cements.

    Science.gov (United States)

    Gallinetti, Sara; Canal, Cristina; Ginebra, Maria-Pau; Ferreira, J

    2014-04-01

    Biphasic calcium phosphate bioceramics composed of hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) have relevant properties as synthetic bone grafts, such as tunable resorption, bioactivity, and intrinsic osteoinduction. However, they have some limitations associated to their condition of high-temperature ceramics. In this work self-setting Biphasic Calcium Phosphate Cements (BCPCs) with different HA/β-TCP ratios were obtained from self-setting α-TCP/β-TCP pastes. The strategy used allowed synthesizing BCPCs with modulated composition, compressive strength, and specific surface area. Due to its higher solubility, α-TCP was fully hydrolyzed to a calcium-deficient HA (CDHA), whereas β-TCP remained unreacted and completely embedded in the CDHA matrix. Increasing amounts of the non-reacting β-TCP phase resulted in a linear decrease of the compressive strength, in association to the decreasing amount of precipitated HA crystals, which are responsible for the mechanical consolidation of apatitic cements. Ca(2+) release and degradation in acidic medium was similar in all the BCPCs within the timeframe studied, although differences might be expected in longer term studies once β-TCP, the more soluble phase was exposed to the surrounding media.

  6. Cell–material interactions on biphasic polyurethane matrix

    Science.gov (United States)

    Dicesare, Patrick; Fox, Wade M.; Hill, Michael J.; Krishnan, G. Rajesh; Yang, Shuying; Sarkar, Debanjan

    2013-01-01

    Cell–matrix interaction is a key regulator for controlling stem cell fate in regenerative tissue engineering. These interactions are induced and controlled by the nanoscale features of extracellular matrix and are mimicked on synthetic matrices to control cell structure and functions. Recent studies have shown that nanostructured matrices can modulate stem cell behavior and exert specific role in tissue regeneration. In this study, we have demonstrated that nanostructured phase morphology of synthetic matrix can control adhesion, proliferation, organization and migration of human mesenchymal stem cells (MSCs). Nanostructured biodegradable polyurethanes (PU) with segmental composition exhibit biphasic morphology at nanoscale dimensions and can control cellular features of MSCs. Biodegradable PU with polyester soft segment and hard segment composed of aliphatic diisocyanates and dipeptide chain extender were designed to examine the effect polyurethane phase morphology. By altering the polyurethane composition, morphological architecture of PU was modulated and its effect was examined on MSC. Results show that MSCs can sense the nanoscale morphology of biphasic polyurethane matrix to exhibit distinct cellular features and, thus, signifies the relevance of matrix phase morphology. The role of nanostructured phases of a synthetic matrix in controlling cell–matrix interaction provides important insights for regulation of cell behavior on synthetic matrix and, therefore, is an important tool for engineering tissue regeneration. PMID:23255285

  7. Biphasic Chromatin Structure and FISH Signals Reflect Intranuclear Order

    Directory of Open Access Journals (Sweden)

    Jyoti P. Chaudhuri

    2005-01-01

    Full Text Available Background and Aim: One of the two parental allelic genes may selectively be expressed, regulated by imprinting, X-inactivation or by other less known mechanisms. This study aims to reflect on such genetic mechanisms. Materials and Methods: Slides from short term cultures or direct smears of blood, bone marrow and amniotic fluids were hybridized with FISH probes singly, combined or sequentially. Two to three hundred cells were examined from each preparation. Results and Aignificance: A small number of cells (up to about 5%, more frequent in leukemia cases, showed the twin features: (1 nuclei with biphasic chromatin, one part decondensed and the other condensed; and (2 homologous FISH signals distributed equitably in those two regions. The biphasic chromatin structure with equitable distribution of the homologous FISH signals may correspond to the two sets of chromosomes, supporting observations on ploidywise intranuclear order. The decondensed chromatin may relate to enhanced transcriptions or advanced replications. Conclusions: Transcriptions of only one of the two parental genomes cause allelic exclusion. Genomes may switch with alternating monoallelic expression of biallelic genes as an efficient genetic mechanism. If genomes fail to switch, allelic exclusion may lead to malignancy. Similarly, a genome-wide monoallelic replication may tilt the balance of heterozygosity resulting in aneusomy, initiating early events in malignant transformation and in predicting cancer mortality.

  8. A New Biphasic Dicalcium Silicate Bone Cement Implant

    Directory of Open Access Journals (Sweden)

    Fausto Zuleta

    2017-07-01

    Full Text Available This study aimed to investigate the processing parameters and biocompatibility of a novel biphasic dicalcium silicate (C2S cement. Biphasic α´L + β-C2Sss was synthesized by solid-state processing, and was used as a raw material to prepare the cement. In vitro bioactivity and biocompatibility studies were assessed by soaking the cement samples in simulated body fluid (SBF and human adipose stem cell cultures. Two critical-sized defects of 6 mm Ø were created in 15 NZ tibias. A porous cement made of the high temperature forms of C2S, with a low phosphorous substitution level, was produced. An apatite-like layer covered the cement’s surface after soaking in SBF. The cell attachment test showed that α´L + β-C2Sss supported cells sticking and spreading after 24 h of culture. The cement paste (55.86 ± 0.23 obtained higher bone-to-implant contact (BIC percentage values (better quality, closer contact in the histomorphometric analysis, and defect closure was significant compared to the control group (plastic. The residual material volume of the porous cement was 35.42 ± 2.08% of the initial value. The highest BIC and bone formation percentages were obtained on day 60. These results suggest that the cement paste is advantageous for initial bone regeneration.

  9. Helical Aharonov-Casher edge states

    OpenAIRE

    Heremans, J. J.; Xu, L. L.

    2010-01-01

    It is shown that an Aharonov-Casher vector potential in a two-dimensional geometry can lead to helical edge states. The Aharonov-Casher vector potential is the electromagnetic dual of the magnetic vector potential, and leads to traveling states at the sample edge in analogy to the integer quantum Hall effect. The helical edge states are predicted to appear in a narrow channel geometry with parabolic or sufficiently symmetric confinement potential. The implications of the helical Aharonov-Cash...

  10. Employing Helicity Amplitudes for Resummation in SCET

    CERN Document Server

    Moult, Ian; Tackmann, Frank J; Waalewijn, Wouter J

    2016-01-01

    Helicity amplitudes are the fundamental ingredients of many QCD calculations for multi-leg processes. We describe how these can seamlessly be combined with resummation in Soft-Collinear Effective Theory (SCET), by constructing a helicity operator basis for which the Wilson coefficients are directly given in terms of color-ordered helicity amplitudes. This basis is crossing symmetric and has simple transformation properties under discrete symmetries.

  11. Revisiting fermion helicity flip in Podolsky's Electromagnetism

    CERN Document Server

    Sales, Jorge Henrique; Thibes, Ronaldo

    2016-01-01

    The spin projection of a massive particle onto its direction of motion is called helicity (or "handedness"). It can therefore be positive or negative. When a particle's helicity changes from positive to negative (or vice-versa) due to its interaction with other particles or fields, we say there is a helicity flip. In this work we show that such helicity flip can be seen for an electron of $20 MeV$ of energy interacting with a charged scalar meson through the exchange of a virtual photon. This photon {\\it does not} necessarily need to be Podolsky's proposed photon; in fact, it is independent of it.

  12. Higher helicity invariants and solar dynamo

    Science.gov (United States)

    Sokolov, D. D.; Illarionov, E. A.; Akhmet'ev, P. M.

    2017-01-01

    Modern models of nonlinear dynamo saturation in celestial bodies (specifically, on the Sun) are largely based on the consideration of the balance of magnetic helicity. This physical variable has also a topological meaning: it is associated with the linking coefficient of magnetic tubes. In addition to magnetic helicity, magnetohydrodynamics has a number of topological integrals of motion (the so-called higher helicity moments). We have compared these invariants with magnetic helicity properties and concluded that they can hardly serve as nonlinear constraints on dynamo action.

  13. Friction Reduction for Microhole CT Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Ken Newman; Patrick Kelleher; Edward Smalley

    2007-03-31

    The objective of this 24 month project focused on improving microhole coiled tubing drilling bottom hole assembly (BHA) reliability and performance, while reducing the drilling cost and complexity associated with inclined/horizontal well sections. This was to be accomplished by eliminating the need for a downhole drilling tractor or other downhole coiled tubing (CT) friction mitigation techniques when drilling long (>2,000 ft.) of inclined/horizontal wellbore. The technical solution to be developed and evaluated in this project was based on vibrating the coiled tubing at surface to reduce the friction along the length of the downhole CT drillstring. The Phase 1 objective of this project centered on determining the optimum surface-applied vibration system design for downhole CT friction mitigation. Design of the system would be based on numerical modeling and laboratory testing of the CT friction mitigation achieved with various types of surface-applied vibration. A numerical model was developed to predict how far downhole the surface-applied vibration would travel. A vibration test fixture, simulating microhole CT drilling in a horizontal wellbore, was constructed and used to refine and validate the numerical model. Numerous tests, with varying surface-applied vibration parameters were evaluated in the vibration test fixture. The data indicated that as long as the axial force on the CT was less than the helical buckling load, axial vibration of the CT was effective at mitigating friction. However, surface-applied vibration only provided a small amount of friction mitigation as the helical buckling load on the CT was reached or exceeded. Since it would be impractical to assume that routine field operations be conducted at less than the helical buckling load of the CT, it was determined that this technical approach did not warrant the additional cost and maintenance issues that would be associated with the surface vibration equipment. As such, the project was

  14. Evaluation of Biphasic Culture System for Mycobacterial Isolation from the Sputum of Patients with Pulmonary Tuberculosis

    Directory of Open Access Journals (Sweden)

    Ghatole M

    2005-01-01

    Full Text Available Mycobacterial diseases continue to cause high morbidity and mortality. Isolation, identification and sensitivity testing form the backbone of laboratory investigations. M. tuberculosis isolation needs 6-8 weeks on conventional egg containing media. For rapid isolation various methods have been evaluated. We evaluated biphasic system (Middlebrook 7H11 agar slant + Middlebrook 9H broth in comparison with Lowenstein - Jensen (LJ medium. In smear positive cases biphasic system showed the recovery rate of 97.05% as against 79.41% on LJ on incubation for 21± 4.44 and 28±3.76 days respectively. In smear negative and culture positive cases biphasic system and LJ showed isolation rates of 91.66% and 66.6% after 36±3.44 and 41± 4.09 days respectively. Biphasic system showed lower contamination rate (1.33%. Biphasic medium is superior to LJ medium in isolation of M. tuberculosis .

  15. Helical coil thermal hydraulic model

    Science.gov (United States)

    Caramello, M.; Bertani, C.; De Salve, M.; Panella, B.

    2014-11-01

    A model has been developed in Matlab environment for the thermal hydraulic analysis of helical coil and shell steam generators. The model considers the internal flow inside one helix and its associated control volume of water on the external side, both characterized by their inlet thermodynamic conditions and the characteristic geometry data. The model evaluates the behaviour of the thermal-hydraulic parameters of the two fluids, such as temperature, pressure, heat transfer coefficients, flow quality, void fraction and heat flux. The evaluation of the heat transfer coefficients as well as the pressure drops has been performed by means of the most validated literature correlations. The model has been applied to one of the steam generators of the IRIS modular reactor and a comparison has been performed with the RELAP5/Mod.3.3 code applied to an inclined straight pipe that has the same length and the same elevation change between inlet and outlet of the real helix. The predictions of the developed model and RELAP5/Mod.3.3 code are in fairly good agreement before the dryout region, while the dryout front inside the helical pipes is predicted at a lower distance from inlet by the model.

  16. Predictors of biphasic reactions in the emergency department for patients with anaphylaxis.

    Science.gov (United States)

    Lee, Sangil; Bellolio, M Fernanda; Hess, Erik P; Campbell, Ronna L

    2014-01-01

    A biphasic reaction is the recurrence of anaphylaxis symptoms within 72 hours of the initial anaphylactic event, without re-exposure to the trigger. Biphasic reactions are uncommon and unpredictable, and risk factors for biphasic reactions are poorly understood. To identify predictors of biphasic anaphylactic reactions in patients with anaphylaxis in the emergency department (ED). Patients of all ages who presented to the ED and met diagnostic criteria for anaphylaxis from April 2008 to January 2013 at an academic medical center with 73,000 annual patient visits were consecutively included. We collected data on patient characteristics, suspected triggers, signs and symptoms, ED management, and disposition. Univariate analyses were performed to estimate the association between potential predictor variables and biphasic reactions. We report associations as odds ratios (OR) and corresponding 95% CIs. Among 541 patients with anaphylaxis, median age was 34.6 years (interquartile range, 18-52 years), and 320 (59%) were female patients. Twenty-one patients (4%) had biphasic reactions. Two pediatric patients, ages of 5 years old and 16 years old, developed a biphasic reaction. The median time between the resolution of initial symptoms and onset of the biphasic reaction was 7 hours (range, 1-72 hours). Biphasic reactions were associated with a history of prior anaphylaxis (OR 2.6 [95% CI, 1.1-6.4]; P = .029), unknown precipitant (OR 2.6 [95% CI, 1.1-6.2]; P = .03), symptoms of diarrhea (OR 4.5 [95% CI, 1.4-14.0]; P = .024), and wheezing (OR 2.6 [95% CI, 1.4-8.9]; P = .029). Patients with a history of prior anaphylaxis, an unknown precipitant, or who present with symptoms of diarrhea or wheezing may be at increased risk for a biphasic reaction. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  17. Segregation of helicity in inertial wave packets

    Science.gov (United States)

    Ranjan, A.

    2017-03-01

    Inertial waves are known to exist in the Earth's rapidly rotating outer core and could be important for the dynamo generation. It is well known that a monochromatic inertial plane wave traveling parallel to the rotation axis (along positive z ) has negative helicity while the wave traveling antiparallel (negative z ) has positive helicity. Such a helicity segregation, north and south of the equator, is necessary for the α2-dynamo model based on inertial waves [Davidson, Geophys. J. Int. 198, 1832 (2014), 10.1093/gji/ggu220] to work. The core is likely to contain a myriad of inertial waves of different wave numbers and frequencies. In this study, we investigate whether this characteristic of helicity segregation also holds for an inertial wave packet comprising waves with the same sign of Cg ,z, the z component of group velocity. We first derive the polarization relations for inertial waves and subsequently derive the resultant helicity in wave packets forming as a result of superposition of two or more waves. We find that the helicity segregation does hold for an inertial wave packet unless the wave numbers of the constituent waves are widely separated. In the latter case, regions of opposite color helicity do appear, but the mean helicity retains the expected sign. An illustration of this observation is provided by (a) calculating the resultant helicity for a wave packet formed by superposition of four upward-propagating inertial waves with different wave vectors and (b) conducting the direct numerical simulation of a Gaussian eddy under rapid rotation. Last, the possible effects of other forces such as the viscous dissipation, the Lorentz force, buoyancy stratification, and nonlinearity on helicity are investigated and discussed. The helical structure of the wave packet is likely to remain unaffected by dissipation or the magnetic field, but can be modified by the presence of linearly stable stratification and nonlinearity.

  18. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  19. From the present status of chest CT screening. The latest report from the laboratory using installation CT

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Yoshimasa [Tokyo Health Service Association (Japan)

    1999-04-01

    The screening that used helical CT was enforced from 1997. Radiographical condition is as follows; voltage 120 kV, current 50 mA, beam width 10 mm, table speed 20 mm/sec/rot. Image data was reconstructed with 10 mm interval using 180 degree opposed beam interpolation. The detecting rate of lung cancer was 5.1% before transduction of CT, but 8.9% after transduction. The rate of stage 1 was 53.5% before transduction but 82.7% after transduction. Among 29 cases of lung cancer, 3 cases were detected with exfoliative cytology of sputum, and 26 cases by CT image. All of lung cancer diagnosed only with helical CT were in stage 1, and 16 cases were adenocarcinoma, and 2 cases were squamous cell carcinoma. Radius of cancer was an average of 30.4 mm before CT transduction, but 16.04 mm after the transduction. Radius of cancer which could be found by chest direct X-ray radiography was an average of 26.25 mm, and that which could be found out only with CT was an average of 11.5 mm. Cancer found by chest direct X-ray radiography was solid tumor, and contrast of image was high. There was also non-solid cancer whose image showed low contrast, in cancer discovered only with CT. In cost-benefit analysis, CT screening is more expensive but more beneficial than photofluoroscopic examination for lung cancer. (K.H.)

  20. CT Enterography

    Science.gov (United States)

    ... You may also be asked to remove hearing aids and removable dental work. Women will be asked to remove bras ... kind, unlike MRI. No radiation remains in a patient's body after a CT ... side effects. Risks There is always a slight chance of cancer ...

  1. Injectable biphasic calcium phosphate bioceramic: The HYDROS concept.

    Science.gov (United States)

    Baroth, Serge; Bourges, Xavier; Goyenvalle, Eric; Aguado, Eric; Daculsi, Guy

    2009-01-01

    A new biphasic calcium phosphate ceramic material has been developed in our laboratory. It is composed of 60% of hydroxyapatite and 40% of beta-tricalcium phosphate, based on three granulometries (submicron, round microporous 80-200 mum and macro microporous 0.5-1 mm particles) and hydrated with water leading the formation of a putty filler for bone repair. Biocompatibility and osteogenicity were tested by filling femoral epiphyses critical size bone defect and lumbar muscles in rabbit. After 3, 6 and 12 weeks of implantation, explants were treated for histology. Results revealed the biocompatibility of the material and intensive resorption of the submicron particle fraction followed by important bone ingrowth whereas osteoconduction was provided by the larger particles.

  2. Magnetic Helicity and the Solar Dynamo

    Science.gov (United States)

    Canfield, Richard C.

    1997-01-01

    The objective of this investigation is to open a new window into the solar dynamo, convection, and magnetic reconnection through measurement of the helicity density of magnetic fields in the photosphere and tracing of large-scale patterns of magnetic helicity in the corona.

  3. The AGS synchrotron with four helical magnets

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas N.; Huang, H.; Roser, T.; MacKay, W.W.; Trbojevic, D.

    2012-05-20

    The idea of using two partial helical magnets was applied successfully to the AGS synchrotron to preserve the proton beam polarization. In this paper we explore in details the idea of using four helical magnets placed symmetrically in the AGS ring. The placement of four helical magnets in the AGS ring provides many advantages over the present setup of the AGS which uses two partial helical magnets. First, the symmetric placement of the four helical magnets allows for a better control of the AGS optics with reduced values of the beta functions especially near beam injection, second, the vertical spin direction during beam injection and extraction is closer to vertical, and third, it provides for a larger 'spin tune gap', which allows the vertical and horizontal tunes to be placed, and prevent the horizontal and vertical intrinsic spin resonances of the AGS to occur during the acceleration cycle. Although the same spin gap can be obtained with a single or two partial helices, the required high field strength of a single helix makes its use impractical, and that of the double helix rather difficult. In this paper we will provide results on the spin tune and on the optics of the AGS with four partial helical magnets, and compare these results with the present setup of the AGS that uses two partial helical magnets.

  4. Helical Magnetic Fields in AGN Jets

    Indian Academy of Sciences (India)

    Y. J. Chen; G.-Y. Zhao; Z.-Q. Shen

    2014-09-01

    We establish a simple model to describe the helical magnetic fields in AGN jets projected on the sky plane and the line-of-sight. This kind of profile has been detected in the polarimetric VLBI observation of many blazar objects, suggesting the existence of helical magnetic fields in these sources.

  5. Helical chirality induction of expanded porphyrin analogues

    Indian Academy of Sciences (India)

    Jun-Ichiro Setsune

    2012-11-01

    Expanded porphyrin analogues with unique figure-eight conformation were prepared by way of useful pyrrole intermediates such as bis(azafulvene)s and 2-borylpyrrole. Supramolecular chirogenesis of cyclooctapyrrole O1 with 32-cycloconjugation was successfully applied to determine absolute configuration of chiral carboxylic acids. Dinuclear CuII complex of cyclooctapyrrole O2 with interrupted -conjugation was resolved by HPLC into enantiomers and their helical handedness was determined by theoretical simulation of their CD spectral pattern. Enantioselective induction of helicity in the metal helicate formation in the presence of a chiral promoter was demonstrated by using ()-(+)-1-(1-phenyl)ethylamine that favoured , helicity. Dinuclear CoII complexes of cyclotetrapyrroletetrapyridine O3 were found to be substitution labile and pick up amino acid anions in water. Those amino acid complexes of O3Co2 were rendered to adopt a particular unidirectional helical conformation preferentially depending on the ligated amino acid anion.

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a stroke, especially with a new technique called Perfusion CT. brain tumors. enlarged brain cavities (ventricles) in ... X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography (CTA) Stroke Brain ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special ... the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT ...

  8. Solubilization and fractionation of paired helical filaments.

    Science.gov (United States)

    González, P J; Correas, I; Avila, J

    1992-09-01

    Paired helical filaments isolated from brains of two different patients with Alzheimer's disease were extensively treated with the ionic detergent, sodium dodecyl sulphate. Filaments were solubilized at different extents, depending on the brain examined, thus suggesting the existence of two types of paired helical filaments: sodium dodecyl sulphate-soluble and insoluble filaments. In the first case, the number of structures resembling paired helical filaments greatly decreased after the detergent treatment, as observed by electron microscopy. Simultaneously, a decrease in the amount of sedimentable protein was also observed upon centrifugation of the sodium dodecyl sulfate-treated paired helical filaments. A sodium dodecyl sulphate-soluble fraction was isolated as a supernatant after low-speed centrifugation of the sodium dodecyl sulphate-treated paired helical filaments. The addition of the non-ionic detergent Nonidet-P40 to this fraction resulted in the formation of paired helical filament-like structures. When the sodium dodecyl sulphate-soluble fraction was further fractionated by high-speed centrifugation, three subfractions were observed: a supernatant, a pellet and a thin layer between these two subfractions. No paired helical filaments were observed in any of these subfractions, even after addition of Nonidet P-40. However, when they were mixed back together, the treatment with Nonidet P-40 resulted in the visualization of paired helical filament-like structures. These results suggest that at least two different components are needed for the reconstitution of paired helical filaments as determined by electron microscopy. The method described here may allow the study of the components involved in the formation of paired helical filaments and the identification of possible factors capable of blocking this process.

  9. The Effect of Alendronate Loaded Biphasic Calcium Phosphate Scaffolds on Bone Regeneration in a Rat Tibial Defect Model

    Directory of Open Access Journals (Sweden)

    Kwang-Won Park

    2015-11-01

    Full Text Available This study investigated the effect of alendronate (Aln released from biphasic calcium phosphate (BCP scaffolds. We evaluated the in vitro osteogenic differentiation of Aln/BCP scaffolds using MG-63 cells and the in vivo bone regenerative capability of Aln/BCP scaffolds using a rat tibial defect model with radiography, micro-computed tomography (CT, and histological examination. In vitro studies included the surface morphology of BCP and Aln-loaded BCP scaffolds visualized using field-emission scanning electron microscope, release kinetics of Aln from BCP scaffolds, alkaline phosphatase (ALP activity, calcium deposition, and gene expression. The in vitro studies showed that sustained release of Aln from the BCP scaffolds consisted of porous microstructures, and revealed that MG-63 cells cultured on Aln-loaded BCP scaffolds showed significantly increased ALP activity, calcium deposition, and gene expression compared to cells cultured on BCP scaffolds. The in vivo studies using radiograph and histology examination revealed abundant callus formation and bone maturation at the site in the Aln/BCP groups compared to the control group. However, solid bony bridge formation was not observed at plain radiographs until 8 weeks. Micro-CT analysis revealed that bone mineral density and bone formation volume were increased over time in an Aln concentration-dependent manner. These results suggested that Aln/BCP scaffolds have the potential for controlling the release of Aln and enhance bone formation and mineralization.

  10. Cationic Nitrogen Doped Helical Nanographenes.

    Science.gov (United States)

    Xu, Kun; Feng, Xinliang; Berger, Reinhard; Popov, Alexey A; Weigand, Jan J; Vincon, Ilka; Machata, Peter; Hennersdorf, Felix; Zhou, Youjia; Fu, Yubin

    2017-09-13

    Herein, we report on the synthesis of a series of novel cationic nitrogen doped nanographenes (CNDN) by rhodium catalyzed annulation reactions. This powerful method allows for the synthesis of cationic nanographenes with non-planar, axial chiral geometries. Single-crystal X-ray analysis reveals helical and cove-edged structures. Compared to their all-carbon analogues, the CNDN exhibit energetically lower lying frontier orbitals with a reduced optical energy gap and an electron accepting behavior. All derivatives show quasi reversible reductions in cyclic voltammetry. Depending on the number of nitrogen dopant, in situ spectroelectrochemistry proves the formation of neutral radicals (one nitrogen dopant) or radical cations (two nitrogen dopants) upon reduction. The developed synthetic protocol paves the way for the design and synthesis of expanded nanographenes or even graphene nanoribbons containing cationic nitrogen doping. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Formation of helical ion chains

    CERN Document Server

    Nigmatullin, Ramil; De Chiara, Gabriele; Morigi, Giovanna; Plenio, Martin B; Retzker, Alex

    2011-01-01

    We study the nonequilibrium dynamics of the linear to zigzag structural phase transition exhibited by an ion chain confined in a trap with periodic boundary conditions. The transition is driven by reducing the transverse confinement at a finite quench rate, which can be accurately controlled. This results in the formation of zigzag domains oriented along different transverse planes. The twists between different domains can be stabilized by the topology of the trap and under laser cooling the system relaxes to a helical chain with possibly nonzero winding number. Molecular dynamics simulations are used to obtain a large sample of possible trajectories for different quench rates. The scaling of the average winding number with different quench rates is compared to the prediction of the Kibble-Zurek theory, and a good quantitative agreement is found.

  12. Best packing of identical helices

    Science.gov (United States)

    Huh, Youngsik; Hong, Kyungpyo; Kim, Hyoungjun; No, Sungjong; Oh, Seungsang

    2016-10-01

    In this paper we prove the unique existence of a ropelength-minimizing conformation of the θ-spun double helix in a mathematically rigorous way, and find the minimal ropelength {{{Rop}}}* (θ )=-\\tfrac{8π }{t} where t is the unique solution in [-θ ,0] of the equation 2-2\\cos (t+θ )={t}2. Using this result, the pitch angles of the standard, triple and quadruple helices are around 39.3771^\\circ , 42.8354^\\circ and 43.8351^\\circ , respectively, which are almost identical with the approximated pitch angles of the zero-twist structures previously known by Olsen and Bohr. We also find the ropelength of the standard N-helix.

  13. Evaluation with low-dose dual-phase helical computed tomography of patients with thyroid lesions

    Institute of Scientific and Technical Information of China (English)

    Li Lin; Wang Yong; Zhao Yanfeng; Zou Shuangmei; Lin Meng; Yu Xiaoduo; Tang Wei

    2014-01-01

    Background The incidence of thyroid cancer has been increasing.Our aim was to evaluate the efficacy of low-dose dualphase helical computed tomography (CT) in the characterization of thyroid lesions,and to discuss the relationship between image characteristics and their pathology.Methods One hundred and six patients with thyroid lesions underwent low-dose dual-phase helical CT after the injection of contrast material.CT scans were obtained at arterial and venous phase with delays of 25 and 65 seconds,and tube current of 60 and 120 mA,respectively.The attenuation change in the lesion between the arterial and venous phase was analyzed and categorized as "increased," "decreased," "mixed" or "no change." Results Histopathologic diagnosis was obtained by surgery in 106 patients (115 lesions).Of the 106 patients,45 had nodular goiter,5 thyroid adenoma,6 thyroiditis,and 50 papillary thyroid carcinoma (PTC) (59 lesions).The attenuation value showed a significant difference (P <0.05) between the arterial and venous phase for the high attenuation area.There was statistical significant difference in terms of attenuation value in high attenuation areas at both phases and in low attenuation areas on arterial phase between nodular goiter and PTC (P <0.05).However,there was no significant difference in attenuation value between adenoma and PTC.Twenty-nine cases (76.3%) of goiter manifested mixed type,3 cases (3/5) of adenoma showed decreased type,6 cases (6/6) of thyroiditis showed increased type,and 55 cases (93.2%) of PTC showed decreased type attenuation.The sensitivity,specificity for thyroid carcinoma by dual-phase CT were 94.9% and 80.4% respectively.The overall diagnostic accuracy for thyroid lesions by dual-phase CT was 87.8%.Conclusions The performance of dual-phase helical CT is related to the pathological structure of the lesions.The analysis of enhancement patterns by using dual-phase helical CT will be helpful in the differential diagnosis of thyroid

  14. Follow-up after stent insertion in the tracheobronchial tree: role of helical computed tomography in comparison with fiberoptic bronchoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, G.R.; Kocier, M.; Calaque, O.; Coulomb, M. [Service Central de Radiologie et Imagerie Medicale, INSERM EMI 9924, CHU, BP 217, 38043, Grenoble Cedex 9 (France); Arbib, F.; Pison, C. [Departement de Medecine Aigue Specialisee (DMAS), CHU Grenoble, CHU, BP 217, 38043, Grenoble Cedex 9 (France); Righini, C. [Service d' Oto Rhino Laryngologie, CHU Grenoble, BP 217, 38043, Grenoble Cedex 9 (France)

    2003-05-01

    The aim of this study was to compare helical CT with fiberoptic bronchoscopy findings to appraise the medium-term results of proximal-airways stenting. Twenty-five patients with 28 endobronchial metallic stents inserted for local advanced malignancy (n=13) or benign diseases (n=12) underwent follow-up CT from 3 days to 50 months (mean 8 months). All studies were obtained using helical CT with subsequent multiplanar reformation and three-dimensional reconstruction including virtual bronchoscopy. The location, shape, and patency of stents and adjacent airway were assessed. The results of CT were compared with the results of fiberoptic bronchoscopy obtained with a mean delay of 2.5 days (SD 9 days) after CT scan. Twelve stents (43%) remained in their original position, patent and without deformity. Sixteen stents were associated with local complications: migration (n=6); external compression with persistent stenosis (n=4); local recurrence of malignancy (n=4); fracture (n=1); and non-congruence between the airway and the stent (n=1). The CT demonstrated all the significant abnormalities demonstrated at fiberoptic bronchoscopy except two moderate stenoses (20%) related to granulomata at the origin of the stent. Ten of 14 stents inserted for benign conditions were without complications as compared with 2 of 14 in malignant conditions (p=0.008). Computed tomography is an accurate noninvasive method for evaluating endobronchial stents. The CT is a useful technique for follow-up of patients who have undergone endobronchial stenting. (orig.)

  15. Magnetic Helicity in a Cyclic Convective Dynamo

    Science.gov (United States)

    Miesch, Mark S.; Zhang, Mei; Augustson, Kyle C.

    2016-05-01

    Magnetic helicity is a fundamental agent for magnetic self-organization in magnetohydrodynamic (MHD) dynamos. As a conserved quantity in ideal MHD, it establishes a strict topological coupling between large and small-scale magnetic fields. The generation of magnetic fields on scales larger than the velocity field is linked to an upscale transfer of magnetic helicity, either locally in spectral space as in the inverse cascade of magnetic helicity in MHD turbulence or non-locally, as in the turbulent alpha-effect of mean-field dynamo theory. Thus, understanding the generation, transport, and dissipation of magnetic helicity is an essential prerequisite to understanding manifestations of magnetic self-organization in the solar dynamo, including sunspots, the prominent dipole and quadrupole moments, and the 22-year magnetic activity cycle. We investigate the role of magnetic helicity in a convective dynamo model that exhibits regular magnetic cycles. The cycle is marked by coherent bands of toroidal field that persist within the convection zone and that are antisymmetric about the equator. When these toriodal bands interact across the equator, it initiates a global restructuring of the magnetic topology that contributes to the reversal of the dipole moment. Thus, the polar field reversals are preceeded by a brief reversal of the subsurface magnetic helicity. There is some evidence that the Sun may exhibit a similar magnetic helicity reversal prior to its polar field reversals.

  16. Single Band Helical Antenna in Axial Mode

    Directory of Open Access Journals (Sweden)

    Parminder Singh

    2012-11-01

    Full Text Available Helical antennas have been widely used in a various useful applications, due to their low weight and low profile conformability, easy and cheap realization.Radiation properties of this antenna are examined both theoretically and experimentally. In this paper, an attempt has been made to investigate new helical antenna structure for Applications. CST MWS Software is used for the simulation and design calculations of the helical antennas. The axial ratio, return loss, VSWR, Directivity, gain, radiation pattern is evaluated. Using CST MWS simulation software proposed antenna is designed/simulated and optimized. The antenna exhibits a single band from 0 GHz to 3 GHz for GPS and several satellite applications

  17. Analysis on two novel spherical helical antennas

    Institute of Scientific and Technical Information of China (English)

    Hou ZHANG; Yingzeng YIN; Dongyu XIA

    2009-01-01

    Two novel spherical helical antennas are designed by projecting the planar equiangular spiral antenna onto hemisphere and partial sphere surfaces.Their radiation properties are analyzed by the moment method with curved basis and test function,and the curves of the voltage standing wave ratio (VSWR),gain,polarization and pattern that change with frequency are also given,respectively.It can be seen that the circular polarization band of the novel hemispherical helical antenna is broader.The gain curve of the partial spherical helical antenna is flatter and the structure is simpler.

  18. Investigation of backfire monofilar helical antenna

    DEFF Research Database (Denmark)

    Smith, Thomas Gunst; Larsen, Niels Vesterdal; Gothelf, Ulrich Vesterager

    2011-01-01

    This paper presents a numerical investigation of the electromagnetic properties of the backfire monofilar helical antenna. The current distribution along the helical conductor, the input impedance, and the front-to-back ratio are calculated and analyzed for the backfire operation of the antenna....... A parametric study of the helical geometry and the resulting antenna characteristics will be described and discussed. The currents and fields are calculated using the simulation software AWAS based on the Method of Moments with a wire representation of the ground plane....

  19. Biphasic influence of dexamethasone exposure on embryonic vertebrate skeleton development

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Xin; Chen, Jian-long; Ma, Zheng-lai; Zhang, Zhao-long; Lv, Shun; Mai, Dong-mei; Liu, Jia-jia [Department of Histology and Embryology, Key Laboratory for Regenerative Medicine of the Ministry of Education, School of Medicine, Jinan University, Guangzhou 510632 (China); Chuai, Manli [Division of Cell and Developmental Biology, University of Dundee, Dundee DD1 5EH (United Kingdom); Lee, Kenneth Ka Ho; Wan, Chao [Stem Cell and Regeneration Thematic Research Programme, School of Biomedical Sciences, Chinese University of Hong Kong, Shatin (Hong Kong); Yang, Xuesong, E-mail: yang_xuesong@126.com [Department of Histology and Embryology, Key Laboratory for Regenerative Medicine of the Ministry of Education, School of Medicine, Jinan University, Guangzhou 510632 (China); Institute of Fetal-Preterm Labor Medicine, Jinan University, Guangzhou 510632 (China)

    2014-11-15

    increased in mesenchymal cell mass treated by low concentration of Dex. Mmp-13 expression was obviously up-regulated by Dex in both mesenchymal cells and primary chondrocyte cultures. And Col10a1 expression was also increased by Dex exposure in chondrocyte. In summary, we have revealed that different concentrations of Dex exposure during early gestation could exert a biphasic effect on vertebrate skeletal development. - Highlights: • Chick embryos occurred shortening of the long bone following Dex exposure. • Dex suppressed chondrocytes proliferation and promoted apoptosis. • Dex exposure decreased ALP production and up-regulated Runx-2 and Mmp-13. • Dex exhibited biphasic effects on chondrogenic proliferation and nodule formation. • The hypertrophy and ossification were accelerated by Dex both in vivo and in vitro.

  20. Moyamoya disease: diagnosis with three-dimensional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Radiology, Kyorin Univ. School of Medicine, Tokyo (Japan)); Makita, K. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Radiology, Social Health Insurance Medical Center, Tokyo (Japan)); Furui, S. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Diagnostic Radiology, Toranomon Kyosai Hospital, Tokyo (Japan))

    1994-08-01

    Our purpose was to assess the value of three-dimensional (3D) CT angiography in the diagnosis of moyamoya disease. We studied seven patients with moyamoya disease proved by conventional angiography. Three-dimensional (3D) CT angiography was performed using rapid sequence or helical (spiral) scanning in conjunction with a bolus injection of intravenous contrast medium. All seven patients could be diagnosed as having moyamoya disease on the basis of the following 3D CT angiographic findings: poor visualisation of the main trunks and/or major branches of anterior and middle cerebral arteries (7 patients); dilated leptomeningeal anastomotic channels from the posterior cerebral arteries (4); and demonstration of ''moyamoya vessels'' in the basal ganglia (2). Although conventional angiography remains the principal imaging technique for demonstrating anatomical changes in detail, less invasive 3D CT angiography provides a solid means of diagnosing moyamoya disease when it is suspected on CT, MRI, or clinical grounds. (orig.)

  1. CT equipment and performance issues: radiation protection 162.

    Science.gov (United States)

    Edyvean, S

    2013-02-01

    Since the development of the CT scanner in the early 1970s, CT scanner technology has continuously developed through technical advancement, faster computer processing, superior detectors and helical and multi-detector scanning modes. As a result, the scope of clinical examinations has broadened considerably, and in parallel, this has been achieved with improvement in image quality and radiation dose efficiency. Despite this, and perhaps because image quality can always be improved at the expense of increased radiation dose, CT examinations are among the highest-dose procedures encountered routinely in medical imaging. The qualitative criteria for acceptability in RP 162 address some functional and operational issues, and the quantitative criteria, in the form of suspension levels, focus primarily around hardware aspects of the CT scanner, though consideration is also given to software, operator aspects and selection of scan protocols. Some of the specific aspects and challenges in modern CT systems, in particular multi-slice and wide beams are also addressed.

  2. Impact of CT in patients with sepsis of unknown origin

    Energy Technology Data Exchange (ETDEWEB)

    Barkhausen, J.; Stoeblen, F.; Mueller, R.D. [University Hospital Essen (Germany). Dept. of Radiology; Dominguez-Fernandez, E. [University Hospital Essen (Germany). Dept. of General Surgery; Henseke, P. [Nycomed-Amersham Arzneimittel GmbH, Muenchen (Germany)

    1999-09-01

    Purpose: To evaluate the diagnostic relevance of CT in patients with sepsis of unknown origin. Material and Methods: Sixty-three consecutive intensive care patients with suspicion of an abscess and negative or inconclusive previous radiological examinations were included. CT was performed using the helical technique. A total of 45 abdominal and 38 chest examinations were evaluated. Results: 5/38 examinations of the chest revealed the source of sepsis (pleural empyema 2, lung abscess 1, mediastinitis 1, retrosternal abscess 1). 7/45 abdominal CT examinations showed the source of sepsis (intraabdominal abscess 2, hepatic abscess 3, intestinal perforation 1, gangrenous colitis 1). Conclusion: CT is useful for the evaluation of patients with fever or sepsis without a known source. Due to the detection of a spetic focus by CT, 19% of the patients in our study could be immediately referred to causal therapy as percutaneous drainage or surgery. (orig.)

  3. Comparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation

    NARCIS (Netherlands)

    M.F. Scholten (Marcoen); T. Szili-Torok (Tamas); L.J.L.M. Jordaens (Luc); A.P.J. Klootwijk (Peter)

    2003-01-01

    textabstractOBJECTIVE: To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. DESIGN: Prospective randomis

  4. Impact of pH and temperature on phase diagrams of different aqueous biphasic systems.

    Science.gov (United States)

    Chakraborty, Arabinda; Sen, Kamalika

    2016-02-12

    The phase diagrams of aqueous biphasic systems impart a distinct idea regarding the feasibility of biphase formation by different water soluble substances at their optimum concentrations. Depending on nature of the components viz., the water soluble polymers, surfactants, salts, amino acids or ionic liquids, a general trend of the biphase formation with varying temperature, pH and concentration has been studied over the recent years. This critical review is an endeavor to assess the general trends of these phase forming components to form biphasic systems with varying conditions of temperature and pH in light of the reported phase diagrams. Suitable explanations for the mechanisms of such behavior have been sorted out. The avenue yet to be explored has been addressed as these systems have a tremendous potential to be the future platform to solve different analytical issues.

  5. Total-liver-volume perfusion CT using 3-D image fusion to improve detection and characterization of liver metastases

    NARCIS (Netherlands)

    Meijerink, Martijn; Waesberghe, van Jan; Weide, van der Lineke; Tol, van den Petrousjka; Meijer, Sybren; Kuijk, van Cornelis

    2008-01-01

    The purpose of this study was to evaluate the feasibility of a totalliver- volume perfusion CT (CTP) technique for the detection and characterization of livermetastases. Twenty patients underwent helical CT of the total liver volume before and 11 times after intravenous contrast-material injection.

  6. Total-liver-volume perfusion CT using 3-D image fusion to improve detection and characterization of liver metastases

    NARCIS (Netherlands)

    Meijerink, Martijn; Waesberghe, van Jan; Weide, van der Lineke; Tol, van den Petrousjka; Meijer, Sybren; Kuijk, van Cornelis

    2008-01-01

    The purpose of this study was to evaluate the feasibility of a totalliver- volume perfusion CT (CTP) technique for the detection and characterization of livermetastases. Twenty patients underwent helical CT of the total liver volume before and 11 times after intravenous contrast-material injection.

  7. Three-dimensional CT of the ossicles of the middle ear

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Yamashita, Koichi [Kanazawa Medical Univ., Uchinada, Ishikawa (Japan)

    1995-02-01

    This study was performed to evaluate the usefulness and limitations of three-dimensional (3-D) imaging of the ossicular chain in the middle ear by high speed helical CT. One dissected human temporal bone, five normal ears, and twelve diseased ears (trauma, ossicular anomaly, cholesteatoma, chronic otitis media) were scanned in 1.0 mm slices and reconstructed at a thickness of 0.2-0.5 mm. All 3-D CT specimens can be observed in any plane and from any direction. Ossicular 3-D CT temporal bone images were reconstructed as if the malleus, incus and stapes were being observed under a microscope. No defect in the ossicles or their joints was seen in the images. The entire structure of the stapes could not be represented by conventional two-dimensional CT, but the 3-D CT in our study showed the head, crus and foot plate of the stapes in detail. Ossicular 3-D CT images of normal ears yielded the same findings as those recorded in the temporal bone. Preoperative diagnostic findings of ossicles in diseased ears were very useful. 3-D CT was diagnostic and its accuracy was confirmed by surgical observations, especially in ossicular anomalies. 3-D CT was also an important method of postoperative evaluation of ossicular reconstruction, i.e. TORP and PORP. It could represent the anatomical relation between prosthesis and the oval window. Postoperative hearing improvement can be compared with 3-D CT findings. High-speed helical CT can scan an object more quickly and clearly than conventional CT, and its biological damage in humans is less than that of other methods. 3-D CT allows obviously clearer reconstruction by helical CT than the other methods. (author).

  8. A closed-form solution of the three-dimensional contact problem for biphasic cartilage layers

    CERN Document Server

    Argatov, I I

    2010-01-01

    A three-dimensional unilateral contact problem for articular cartilage layers is considered in the framework of the biphasic cartilage model. The articular cartilages bonded to subchondral bones are modeled as biphasic materials consisting of a solid phase and a fluid phase. It is assumed that the subchondral bones are rigid and shaped like elliptic paraboloids. The obtained analytical solution is valid over long time periods and can be used for increasing loading conditions.

  9. Biphasic oxidation of oxy-hemoglobin in bloodstains.

    Directory of Open Access Journals (Sweden)

    Rolf H Bremmer

    Full Text Available BACKGROUND: In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO(2 to met-hemoglobin (met-Hb and hemichrome (HC. The fractions of HbO(2, met-Hb and HC in a bloodstain can be used for age determination of bloodstains. In this study, we further analyze the conversion of HbO(2 to met-Hb and HC, and determine the effect of temperature and humidity on the conversion rates. METHODOLOGY: The fractions of HbO(2, met-Hb and HC in a bloodstain, as determined by quantitative analysis of optical reflectance spectra (450-800 nm, were measured as function of age, temperature and humidity. Additionally, Optical Coherence Tomography around 1300 nm was used to confirm quantitative spectral analysis approach. CONCLUSIONS: The oxidation rate of HbO(2 in bloodstains is biphasic. At first, the oxidation of HbO(2 is rapid, but slows down after a few hours. These oxidation rates are strongly temperature dependent. However, the oxidation of HbO(2 seems to be independent of humidity, whereas the transition of met-Hb into HC strongly depends on humidity. Knowledge of these decay rates is indispensable for translating laboratory results into forensic practice, and to enable bloodstain age determination on the crime scene.

  10. Aqueous biphasic systems involving alkylsulfate-based ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Deive, Francisco J. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Rodriguez, Ana [Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Marrucho, Isabel M., E-mail: imarrucho@itqb.unl.pt [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Rebelo, Luis P.N. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal)

    2011-11-15

    Highlights: > K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4} act as phase promoter in aqueous solutions of ILs. > Remarkable influence of alkyl-chain length on solubility curves of alkylsulfate-based ILs. > Merchuck correlation was used for describing these systems. > {Delta}S{sub hyd} and Hofmeister series were used to discuss the different salting out effects. - Abstract: The specific effects of K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4}, as high charge-density inorganic salts and thus inducers of the formation of aqueous biphasic systems (ABS) containing several ethyl-methylimidazolium alkylsulfate ionic liquids, C{sub 2}MIM C{sub n}SO{sub 4} (n = 2, 4, 6, or 8), have been assessed at T = 298.15 K. The results are analyzed in the light of the Hofmeister series. The influence of different alkyl chain lengths in the anion, together with the ability of the selected inorganic salts to induce the formation of ABS, is discussed. Phase diagrams have been determined through turbidimetry, including tie lines assignments from mass phase ratios according to the lever - arm rule. The Merchuck equation was satisfactorily used to correlate the solubility curve.

  11. RADIOGRAPHIC IMAGING OF BIPHASIC SYNOVIAL SARCOMA ON LEFT ELBOW

    Directory of Open Access Journals (Sweden)

    Sitanggang Firman P

    2013-04-01

    Full Text Available Synovial sarcoma is the fourth most common type of sarcoma. It represents between 5% -10% of all soft tissue sarcomas and most prevalent in aged between 15 - 40 years. Synovial sarcoma is the most commonly misdiagnosed soft tissue malignancy, initially as an inflammation process,often because it may be slow-growing, have a benign appearance on imaging studies, may vary in size, and may have pain similar to that associated with trauma.    A rare case is presented of 17 years old women with a synovial sarcoma biphasic. The primary tumor originated in the left elbow since 2004. Since then, the patient has had repeated passive or active left elbow pain and tenderness. No history of trauma. She has not developed metastases of the lung. The patient refused to have surgery and others medical procedures that already planned and explained to her. The conclusion of this case report point that radiology is important to diagnosis and planning for further management

  12. Biphasic flow: structure and upscaling, consequences on macroscopic transport properties

    CERN Document Server

    Toussaint, Renaud; Méheust, Yves; Løvoll, Grunde; Jankov, Mihailo; Schäfer, Gerhard; Schmittbuhl, Jean

    2012-01-01

    In disordered porous media, two-phase flow of immiscible fluids (biphasic flow) is organized in patterns that sometimes exhibit fractal geometries over a range of length scales, depending on the capillary, gravitational and viscous forces at play. These forces, as well as the boundary conditions, also determine whether the flow leads to the appearance of fingering pathways, i.e., unstable flow, or not. We present here a short review of these aspects, focusing on drainage and summarizing when these flows are expected to be stable or not, what fractal dimensions can be expected, and in which range of scales. We base our review on experimental studies performed in two-dimensional Hele-Shaw cells, or addressing three dimensional porous media by use of several imaging techniques. We first present configurations in which solely capillary forces and gravity play a role. Next, we review configurations in which capillarity and viscosity are the main forces at play. Eventually, we examine how the microscopic geometry o...

  13. Biphasic regulation of lysosomal exocytosis by oxidative stress.

    Science.gov (United States)

    Ravi, Sreeram; Peña, Karina A; Chu, Charleen T; Kiselyov, Kirill

    2016-11-01

    Oxidative stress drives cell death in a number of diseases including ischemic stroke and neurodegenerative diseases. A better understanding of how cells recover from oxidative stress is likely to lead to better treatments for stroke and other diseases. The recent evidence obtained in several models ties the process of lysosomal exocytosis to the clearance of protein aggregates and toxic metals. The mechanisms that regulate lysosomal exocytosis, under normal or pathological conditions, are only beginning to emerge. Here we provide evidence for the biphasic effect of oxidative stress on lysosomal exocytosis. Lysosomal exocytosis was measured using the extracellular levels of the lysosomal enzyme beta-hexosaminidase (ß-hex). Low levels or oxidative stress stimulated lysosomal exocytosis, but inhibited it at high levels. Deletion of the lysosomal ion channel TRPML1 eliminated the stimulatory effect of low levels of oxidative stress. The inhibitory effects of oxidative stress appear to target the component of lysosomal exocytosis that is driven by extracellular Ca(2+). We propose that while moderate oxidative stress promotes cellular repair by stimulating lysosomal exocytosis, at high levels oxidative stress has a dual pathological effect: it directly causes cell damage and impairs damage repair by inhibiting lysosomal exocytosis. Harnessing these adaptive mechanisms may point to pharmacological interventions for diseases involving oxidative proteotoxicity or metal toxicity.

  14. Osteochondral tissue engineering with biphasic scaffold: current strategies and techniques.

    Science.gov (United States)

    Shimomura, Kazunori; Moriguchi, Yu; Murawski, Christopher D; Yoshikawa, Hideki; Nakamura, Norimasa

    2014-10-01

    The management of osteoarthritis (OA) remains challenging and controversial. Although several clinical options exist for the treatment of OA, regeneration of the damaged articular cartilage has proved difficult due to the limited healing capacity. With the advancements in tissue engineering and cell-based technologies over the past decade, new therapeutic options for patients with osteochondral lesions potentially exist. This review will focus on the feasibility of tissue-engineered biphasic scaffolds, which can mimic the native osteochondral complex, for osteochondral repair and highlight the recent development of these techniques toward tissue regeneration. Moreover, basic anatomy, strategy for osteochondral repair, the design and fabrication methods of scaffolds, as well as the choice of cells, growth factor, and materials will be discussed. Specifically, we focus on the latest preclinical animal studies using large animals and clinical trials with high clinical relevance. In turn, this will facilitate an understanding of the latest trends in osteochondral repair and contribute to the future application of such clinical therapies in patients with OA.

  15. Shielding requirements in helical tomotherapy

    Science.gov (United States)

    Baechler, S.; Bochud, F. O.; Verellen, D.; Moeckli, R.

    2007-08-01

    Helical tomotherapy is a relatively new intensity-modulated radiation therapy (IMRT) treatment for which room shielding has to be reassessed for the following reasons. The beam-on-time needed to deliver a given target dose is increased and leads to a weekly workload of typically one order of magnitude higher than that for conventional radiation therapy. The special configuration of tomotherapy units does not allow the use of standard shielding calculation methods. A conventional linear accelerator must be shielded for primary, leakage and scatter photon radiations. For tomotherapy, primary radiation is no longer the main shielding issue since a beam stop is mounted on the gantry directly opposite the source. On the other hand, due to the longer irradiation time, the accelerator head leakage becomes a major concern. An analytical model based on geometric considerations has been developed to determine leakage radiation levels throughout the room for continuous gantry rotation. Compared to leakage radiation, scatter radiation is a minor contribution. Since tomotherapy units operate at a nominal energy of 6 MV, neutron production is negligible. This work proposes a synthetic and conservative model for calculating shielding requirements for the Hi-Art II TomoTherapy unit. Finally, the required concrete shielding thickness is given for different positions of interest.

  16. Motion of a helical vortex

    CERN Document Server

    Fuentes, Oscar Velasco

    2015-01-01

    We study the motion of a single helical vortex in an unbounded, inviscid, incompressible fluid. The vortex is an infinite tube whose centerline is a helix and whose cross section is a circle of small radius (compared to the radius of curvature) where the vorticity is uniform and parallel to the centerline. Ever since Joukowsky (1912) deduced that this vortex translates and rotates steadily without change of form, numerous attempts have been made to compute these self-induced velocities. Here we use Hardin's (1982) solution for the velocity field to find new expressions for the vortex's linear and angular velocities. Our results, verified by numerically computing the Helmholtz integral and the Rosenhead-Moore approximation to the Biot-Savart law, are more accurate than previous results over the whole range of values of the vortex pitch and cross-section. We then use the new formulas to study the advection of passive particles near the vortex; we find that the vortex's motion and capacity to transport fluid dep...

  17. Helical Two-Revolutional Cyclical Surface

    Directory of Open Access Journals (Sweden)

    Tatiana Olejníková

    2009-12-01

    Full Text Available Paper presents a family of helical two-revolutional cyclical surfaces, which arecreated by movement of the circle alongside the helical cycloidal curve, where circle islocated in the curve normal plane and its centre is on this curve. Helical cycloidal curvecan be created by simultaneous revolution of a point about two different axes 3o, 2o and byscrewing about axis 1o in the space. Form of the helical cycloidal curve and also of thehelical two-revolutional cyclical surface is dependent on the relative position of the threeaxes of revolutions, on multiples of angular velocities and orientations of separaterevolutions. Analytic representation, classification of surfaces and some of their geometricproperties are derived.

  18. Helicity at Photospheric and Chromospheric Heights

    CERN Document Server

    Tiwari, S K; Sankarasubramanian, K

    2009-01-01

    In the solar atmosphere the twist parameter $\\alpha$ has the same sign as magnetic helicity. It has been observed using photospheric vector magnetograms that negative/positive helicity is dominant in the northern/southern hemisphere of the Sun. Chromospheric features show dextral/sinistral dominance in the northern/southern hemisphere and sigmoids observed in X-rays also have a dominant sense of reverse-S/forward-S in the northern/southern hemisphere. It is of interest whether individual features have one-to-one correspondence in terms of helicity at different atmospheric heights. We use UBF \\Halpha images from the Dunn Solar Telescope (DST) and other \\Halpha data from Udaipur Solar Observatory and Big Bear Solar Observatory. Near-simultaneous vector magnetograms from the DST are used to establish one-to-one correspondence of helicity at photospheric and chromospheric heights. We plan to extend this investigation with more data including coronal intensities.

  19. Spin versus helicity in processes involving transversity

    CERN Document Server

    Mekhfi, Mustapha

    2011-01-01

    We construct the spin formalism in order to deal in a direct and natural way with processes involving transversity which are now of increasing popularity. The helicity formalism which is more appropriate for collision processes of definite helicity has been so far used also to manage processes with transversity, but at the price of computing numerous helicity amplitudes generally involving unnecessary kinematical variables.In a second step we work out the correspondence between both formalisms and retrieve in another way all results of the helicity formalism but in simpler forms.We then compute certain processes for comparison.A special process:the quark dipole magnetic moment is shown to be exclusively treated within the spin formalism as it is directly related to the transverse spin of the quark inside the baryon.

  20. Magnetic Helicity Conservation and Astrophysical Dynamos

    CERN Document Server

    Vishniac, E T; Vishniac, Ethan T.; Cho, Jungyeon

    2000-01-01

    We construct a magnetic helicity conserving dynamo theory which incorporates a calculated magnetic helicity current. In this model the fluid helicity plays a small role in large scale magnetic field generation. Instead, the dynamo process is dominated by a new quantity, derived from asymmetries in the second derivative of the velocity correlation function, closely related to the `twist and fold' dynamo model. The turbulent damping term is, as expected, almost unchanged. Numerical simulations with a spatially constant fluid helicity and vanishing resistivity are not expected to generate large scale fields in equipartition with the turbulent energy density. In fact, there seems to be little prospect for driving a fast dynamo in a closed box containing homogeneous turbulence. On the other hand, there is an efficient analog to the $\\alpha-\\Omega$ dynamo. Systems whose turbulence is driven by some anisotropic local instability in shearing flow, like real stars and accretion disks, and some computer simulations, ma...

  1. Synthesis and structure of neutral double helicate

    Institute of Scientific and Technical Information of China (English)

    SU, Xun-Cheng; ZHOU, Zhi-Fen; ZHU, Shou-Rong; CHEN, Yun-Ti; LENG, Xue-Bing; WENG, Lin-Hong; LIN, Hua-Kuan

    2000-01-01

    A new approach to geaerating supramolecular architectures, based on easy-to-prepare sehiff base ligands, is described to gether with its application to the self-assembly of supramolecu lar neutral double helicates.

  2. Mechanical resonances of helically coiled carbon nanowires

    National Research Council Canada - National Science Library

    Saini, D; Behlow, H; Podila, R; Dickel, D; Pillai, B; Skove, M J; Serkiz, S M; Rao, A M

    2014-01-01

    ...) mainly due to their geometrical complexity. The advent of helically coiled micro/nanoscale structures in nano-robotics, nano-inductors, and impact protection coatings has necessitated the development of new methodologies for determining...

  3. Microfluidic Lithography of Bioinspired Helical Micromotors.

    Science.gov (United States)

    Yu, Yunru; Shang, Luoran; Gao, Wei; Zhao, Ze; Wang, Huan; Zhao, Yuanjin

    2017-07-29

    Considerable efforts have been devoted to developing artificial micro/nanomotors that can convert energy into movement. A flow lithography integrated microfluidic spinning and spiraling system is developed for the continuous generation of bioinspired helical micromotors. Because the generation processes could be precisely tuned by adjusting the flow rates and the illuminating frequency, the length, diameter, and pitch of the helical micromotors were highly controllable. Benefiting from the fast online gelation and polymerization, the resultant helical micromotors could be imparted with Janus, triplex, and core-shell cross-sectional structures that have never been achieved by other methods. Owing to the spatially controlled encapsulation of functional nanoparticles in the microstructures, the helical micromotors can perform locomotion not only by magnetically actuated rotation or corkscrew motion but also through chemically powered catalytic reaction. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Helical magnetized wiggler for synchrotron radiation laser

    CERN Document Server

    Wang Mei; Hirshfield, J L

    1999-01-01

    A helical magnetized iron wiggler has been built for a novel infrared synchrotron radiation laser (SRL) experiment. The wiggler consists of four periods of helical iron structure immersed in a solenoid field. This wiggler is to impart transverse velocity to a prebunched 6 MeV electron beam, and thus to obtain a desired high orbit pitch ratio for the SRL. Field tapering at beam entrance is considered and tested on a similar wiggler. Analytic and simulated characteristics of wigglers of this type are discussed and the performance of the fabricated wigglers is demonstrated experimentally. A 4.7 kG peak field was measured for a 6.4 mm air gap and a 5.4 cm wiggler period at a 20 kG solenoid field. The measured helical fields compare favorably with the analytical solution. This type of helical iron wigglers has the potential to be scaled to small periods with strong field amplitude.

  5. STUDY ON A NOVEL ELLIPSOIDAL HELICAL ANTENNA

    Institute of Scientific and Technical Information of China (English)

    Xia Dongyu; Zhang Hou; Wang Chong; Zhang Qianyue

    2007-01-01

    A novel ellipsoidal helical antenna is proposed and studied in this letter.As a special instance,the hemispherical helical antennas are analyzed firstly,which indicates that the characteristics of a two-arm unit are better than that of a single-arm unit.Based on this,the ellipsoidal helical antenna,formed by changing the axial direction's dimension of the two-arm hemispherical helical antenna,is analyzed by the moment method with curved basic and testing function.The effects to VSWR (Voltage Standing Wave Ratio),gain,polarization and patterns by the axial direction's dimensions are investigated.The study results provide dependable gist to the choice of antenna format according to the practical requirements.

  6. Kinematic dynamo induced by helical waves

    OpenAIRE

    Wei, Xing

    2014-01-01

    We investigate numerically the kinematic dynamo induced by the superposition of two helical waves in a periodic box as a simplified model to understand the dynamo action in astronomical bodies. The effects of magnetic Reynolds number, wavenumber and wave frequency on the dynamo action are studied. It is found that this helical-wave dynamo is a slow dynamo. There exists an optimal wavenumber for the dynamo growth rate. A lower wave frequency facilitates the dynamo action and the oscillations o...

  7. Cosmological Magnetic Fields from Primordial Helical Seeds

    CERN Document Server

    Sigl, G

    2002-01-01

    Most early Universe scenarios predict negligible magnetic fields on cosmological scales if they are unprocessed during subsequent expansion of the Universe. We present a new numerical treatment of the evolution of primordial fields and apply it to weakly helical seeds as they occur in certain early Universe scenarios. We find that initial helicities not much larger than the baryon to photon number can lead to fields of about 10^{-13} Gauss with coherence scales slightly below a kilo-parsec today.

  8. Duality and helicity: A symplectic viewpoint

    Science.gov (United States)

    Elbistan, M.; Duval, C.; Horváthy, P. A.; Zhang, P.-M.

    2016-10-01

    The theorem which says that helicity is the conserved quantity associated with the duality symmetry of the vacuum Maxwell equations is proved by viewing electromagnetism as an infinite dimensional symplectic system. In fact, it is shown that helicity is the moment map of duality acting as an SO (2) group of canonical transformations on the symplectic space of all solutions of the vacuum Maxwell equations.

  9. A biphasic theory for the viscoelastic behaviors of vocal fold lamina propria in stress relaxation.

    Science.gov (United States)

    Zhang, Yu; Czerwonka, Lukasz; Tao, Chao; Jiang, Jack J

    2008-03-01

    In this study, a biphasic theory is applied to investigate the viscoelastic behaviors of vocal fold lamina propria during stress relaxation. The vocal fold lamina propria tissue is described as a biphasic material composed of a solid phase and an interstitial fluid phase. The biphasic theory reveals the interaction between the solid and the fluid. For the one-dimensional case, the analytical solutions of solid displacement, fluid velocity, and stress are derived. The biphasic theory predicts the stress relaxation of the vocal fold lamina propria. The quasilinear viscoelastic model as well as its higher-order elastic parameters can be derived from this biphasic theory. Furthermore, the fluid is found to support the majority of the stress at the early stage of stress relaxation; however, when the time becomes sufficiently large, the solid eventually bears all the stress. The early fluid stress support is much higher than the eventual solid support and may be important for understanding the effects of dehydration on tissue damage. By considering the solid-fluid structure of the vocal fold lamina propria, the biphasic theory allows for a more physical theory of tissue viscoelasticity than a single phase solid description and may provide a valuable physical mechanism for the observed vocal fold rheologic behaviors.

  10. A mixed-penalty biphasic finite element formulation incorporating viscous fluids and material interfaces.

    Science.gov (United States)

    Chan, B; Donzelli, P S; Spilker, R L

    2000-06-01

    The fluid viscosity term of the fluid phase constitutive equation and the interface boundary conditions between biphasic, solid and fluid domains have been incorporated into a mixed-penalty finite element formulation of the linear biphasic theory for hydrated soft tissue. The finite element code can now model a single-phase viscous incompressible fluid, or a single-phase elastic solid, as limiting cases of a biphasic material. Interface boundary conditions allow the solution of problems involving combinations of biphasic, fluid and solid regions. To incorporate these conditions, the volume-weighted mixture velocity is introduced as a degree of freedom at interface nodes so that the kinematic continuity conditions are satisfied by conventional finite element assembly techniques. Results comparing our numerical method with an independent, analytic solution for the problem of Couette flow over rigid and deformable porous biphasic layers show that the finite element code accurately predicts the viscous fluid flows and deformation in the porous biphasic region. Thus, the analysis can be used to model the interface between synovial fluid and articular cartilage in diarthrodial joints. This is an important step toward modeling and understanding the mechanisms of joint lubrication and another step toward fully modeling the in vivo behavior of a diarthrodial joint.

  11. CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Korobkin, M. [Dept. of Radiology, Univ. of Michigan, Ann Arbor, MI (United States)

    2005-11-15

    With the advent of multidetector row CT scanners, evaluation of the urothelium of the entire urinary tract with high-resolution thin sections during a single breath-hold has become a reality. Multidetector CT urography (MDCTU) is a single examination that allows evaluation of potential urinary tract calculi, renal parenchymal masses, and both benign and malignant urothelial lesions. Initial results with this new technique are encouraging. Current investigations of MDCTU focus on methods to improve opacification and distension of the upper urinary tract - the collecting systems, pelvis, and ureters. The role of abdominal compression, infusion of saline and/or furosemide, and optimal time delay of excretory phase imaging is being explored. Upper tract urothelial malignancies, including small lesions less the 5 mmin diameter, can be detected with high sensitivity. Methods to reduce radiation exposure are being explored, including split-bolus contrast injection techniques that combine nephrographic and excretory phases into a single phase. It is likely that in the near future, radiological evaluation of significant unexplained hematuria or of known or prior urothelial malignancy will consist of a single examination - MDCTU. (orig.)

  12. The AGS with four helical magnets

    Energy Technology Data Exchange (ETDEWEB)

    Tsoupas, N.; Huang, H.; MacKay, W.W.; Roser, T.; Trbojevic, D.

    2010-02-25

    The idea of using multiple partial helical magnets was applied successfully to the AGS synchrotron, to preserve the proton beam polarization. In this paper we explore in details the idea of using four helical magnets placed symmetrically in the AGS ring. This modification provides many advantages over the present setup of the AGS that uses two partial helical magnets. First, it provides a larger 'spin tune gap' for the placement of the vertical betatron tune of the AGS during acceleration, second, the vertical spin direction during the beam injection and extraction is closer to vertical, third, the symmetric placement of the snakes allows for a better control of the AGS optics, and for reduced values of the beta and eta functions, especially near injection, fourth, the optical properties of the helical magnets also favor the placement of the horizontal betatron tune in the 'spin tune gap', thus eliminating the horizontal spin resonances. In this paper we provide results on the spin tune and on the optics of the AGS with four partial helical magnets, and we compare these results with the present setup of the AGS that uses two partial helical magnets.

  13. Evaluation of an extracellular matrix-derived acellular biphasic scaffold/cell construct in the repair of a large articular high-load-bearing osteochondral defect in a canine model

    Institute of Scientific and Technical Information of China (English)

    YANG Qiang; MA Xin-long; HU Yong-cheng; XU Bao-shan; PENG Jiang; LU Shi-bi; GUO Quan-yi; ZHAO Bin; ZHANG Li; WANG Ai-yuan; XU Weng-jing; XIA Qun

    2011-01-01

    Background Osteochondral lesion repair is a challenging area of orthopedic surgery.Here we aimed to develop an extraceliular matrix-derived,integrated,biphasic scaffold and to investigate the regeneration potential of the scaffold loaded with chondrogenically-induced bone marrow-derived mesenchymal stem cells (BMSCs) in the repair of a large,high-load-bearing,osteochondral defect in a canine model.Methods The biphasic scaffolds were fabricated by combining a decellularization procedure with a freeze-drying technique and characterized by scanning electron microscopy (SEM) and micro-computed tomography (micro-CT).Osteochondral constructs were fabricated in vitro using chondrogenically-induced BMSCs and a biphasic scaffold,then assessed by SEM for cell attachment.Osteochondral defects (4.2 mm (diameter) x 6 mm (depth)) were created in canine femoral condyles and treated with a construct of the biphasic scaffold/chondrogenically-induced BMSCs or with a cell-free scaffold (control group).The repaired defects were evaluated for gross morphology and by histological,biochemical,biomechanical and micro-CT analyses at 3 and 6 months post-implantation.Results The osteochondral defects of the experimental group showed better repair than those of the control group.Statistical analysis demonstrated that the macroscopic and histologic grading scores of the experimental group were always higher than those of the control group,and that the scores for the experimental group at 6 months were significantly higher than those at 3 months.The cartilage stiffness in the experimental group (6 months) was (6.95±0.79)N/mm,70.77% of normal cartilage; osteochondral bone stiffness in the experimental group was (158.16±94.30) N/mm,74.95% of normal tissue; glycosaminoglycan content of tissue-engineered neocartilage was (218±21.6) μg/mg (dry weight),84.82% of native cartilage.Micro-CT analysis of the subchondral bone showed mature trabecular bone regularly formed at 3 and 6 months

  14. Alternative Methods for Field Corrections in Helical Solenoids

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, M. L. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Krave, S. T. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Tompkins, J. C. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Yonehara, K. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Flanagan, G. [Muons Inc., Batavia, IL (United States); Kahn, S. A. [Muons Inc., Batavia, IL (United States); Melconian, K. [Texas A & M Univ., College Station, TX (United States)

    2015-05-01

    Helical cooling channels have been proposed for highly efficient 6D muon cooling. Helical solenoids produce solenoidal, helical dipole, and helical gradient field components. Previous studies explored the geometric tunability limits on these main field components. In this paper we present two alternative correction schemes, tilting the solenoids and the addition of helical lines, to reduce the required strength of the anti-solenoid and add an additional tuning knob.

  15. Three-dimensional multislice CT imaging of otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Miyako [Yanagibasi Hospital, Tokyo (Japan); Yoshikawa, Hiroshi; Hosokawa, Akira; Furukawa, Tomoyasu; Ichikawa, Ginichiro [Juntendo Univ., Tokyo (Japan). School of Medicine; Wada, Akihiro; Ando, Ichiro [Juntendo Univ., Chiba (Japan). Urayasu Hospital

    2002-07-01

    In recent years, the multislice CT system has come into practical use that enables table movement of half mm, resulting in a significant improvement in resolution. The use of this CT system enables to depict the entire auditory ossicles, including the stapes. 3D reconstruction was performed using helical CT data in 5 patients with chronic otitis media and 5 patients with cholesteatoma. An Aquilion Multi (Toshiba) multislice helical CT scanner and a Xtension (Toshiba) image workstation were used in this study. We demonstrated the 3D display with axial, coronal and sagittal images. Compared with the normal ears, it was necessary to set a higher threshold for the affected ears. It is important to select suitable threshold for demonstration of 3D images optimally. Bone destruction of the stapes was confirmed at surgery in 2 ears. The stapes was observed at 3D-CT imaging in other 18 ears. It was found that the 3D images of the ossicular destruction in ears with cholesteatoma were consistent with surgical findings. It is therefore concluded that 3D imaging of the middle ear using a multislice CT scanner is clinically useful. (author)

  16. Usefulness of helical computed tomography in diagnosing pulmonary vein stenosis in infants.

    Directory of Open Access Journals (Sweden)

    Ohtsuki,Shinnichi

    2005-06-01

    Full Text Available

    We investigated the usefulness of helical computed tomography(CTin the morphological diagnosis of pulmonary vein stenosis, particularly that in infants and small children. In total, 20 helical CT examinations were performed in 10 post-operative cases of Total Anomalous Pulmonary Venous Drainage(TAPVD, 3 cases of single right ventricle, and 1 case of single left ventricle. In all cases, distinct morphological imaging was possible. Pulmonary vein stenosis could be categorized into three types: (1stenosis from the anastomosis of the common pulmonary vein (CPV-the left atrium (LA to the peripheral pulmonary vein; (2 stenosis only at the anastomosis of CPV-LA; and (3 stenosis due to compression by nearby organs. Coronal views by multiplanar reconstruction (MPR provided morphological information along the up-down direction of the body axis. Morphological diagnosis of pulmonary vein stenosis is important in deciding prognosis and therapeutic regimens, and helical CT was considered useful for such diagnosis in our 14 young patients.

  17. CT investigations in children. Technique and indications. CT-Untersuchungen beim Kind. Technik und Indikationen

    Energy Technology Data Exchange (ETDEWEB)

    Stoever, B. (Charite Campus Virchow-Klinikum, Berlin (Germany). Inst. fuer Paediatrische Radiologie); Rogalla, P. (Humboldt-Universitaet, Berlin (Germany). Inst. fuer Roentgendiagnostik)

    1999-06-01

    Technical advantages of spiral technology are of great usefulness in diagnostic imaging of thorax and abdomen in children. The rapid imaging time allows the examination of an entire organ while scanning with breath holding or while the child is quietly breathing, resulting in a decreased need for sedation. In addition especially examinations of the chest and to some extend CT-investigations of the abdomen are performed with reduced radiation dose achieved by reducing the tube loading. Radiation dose reduction 70% is possible without loss of relevant diagnositc information. Spiral low-dose CT in pediatric chest imaging is useful in evaluating parenchymal lung diseases, mediastinal masses and central airway malformations. Whether abdominal helical CT can be replaced by MRI has to be decided in each individual case. When an exact protocol is used, sufficient contrast material given, scan-delay optimized and postprocessing reconstructions are performed, usefull additional diagnostic informations are obtained by the method. (orig.)

  18. Design and evaluation of lornoxicam bilayered tablets for biphasic release

    Directory of Open Access Journals (Sweden)

    Songa Ambedkar Sunil

    2012-12-01

    Full Text Available The objective of the present investigation was to develop bilayered tablets of lornoxicam to achieve biphasic release pattern. A bilayered tablet, consisting of an immediate and controlled release layer, was prepared by direct compression technique. The controlled release effect was achieved by using various hydrophilic natural, semi synthetic and synthetic controlled release polymers such as xanthan gum, hydroxypropyl methylcellulose (HPMC and polyethylene oxide (PEO to modulate the release of the drug. The in vitro drug release profiles showed the biphasic release behavior in which the immediate release (IR layer containing the lornoxicam was released within 15 minutes, whereas the controlled release (CR layer controlled the drug release for up to 24 h. All the bilayered tablets formulated have followed the zero order release with non-Fickian diffusion controlled release mechanism after the initial burst release. FTIR studies revealed that there was no interaction between the drug and polymers used in the study. Statistical analysis (ANOVA showed no significant difference in the cumulative amount of drug release after 15 min, but significant difference (p O objetivo do presente trabalho foi desenvolver comprimidos bicamada de lornoxicam para atingir padrão de liberação bifásica. Preparou-se, por compressão direta, comprimido bicamada, consistindo de uma camada de liberação imediata e uma de liberação controlada. A liberação controlada foi obtida pelo uso de vários polímeros naturais hidrofílicos, semi-sintéticos e sintéticos, tais como goma xantana, hidroxipropilmetil celulose (HPMC e óxido de polietileno (PEO para modular a liberação do fármaco. Os perfis de liberação in vitro mostraram comportamento bifásico em que a camada de liberação imediata (IR contendo lornoxicam foi liberada em 15 minutos, enquanto a camada de liberação controlada (CR liberou o fármaco em mais de 24 horas, Todos os comprimidos bicamada

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and accurate. A ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an implanted medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT Scanning of the Abdomen and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed tomography, ... the body being studied. top of page How is the CT scan performed? The technologist begins by ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ... after the procedure? CT exams are generally painless, fast and easy. With multidetector CT, the amount of ...

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen ... and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a ...

  4. Abdominal and Pelvic CT

    Science.gov (United States)

    ... Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen ... and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a ...

  5. Hydrogels of Superlong Helices to Synthesize Hybrid Ag-Helical Nanomaterials.

    Science.gov (United States)

    Li, Guihua; Wang, Yitong; Wang, Ling; Song, Aixin; Hao, Jingcheng

    2016-11-22

    The gelation behavior of mixtures of sodium deoxycholate (NaDC) and glutathione (GSH) in water is investigated. The system exhibits a structural transition of self-assembled hydrogels from nanofibers to nanohelix structures, and then to helical ribbons with increasing GSH concentration. Superlong helical nanofibers with left- and right-handed orientations are produced by tuning the concentration of GSH at a fixed concentration of NaDC. Random coil and β-sheet structures are significant for the formation of the helical structures, and are indicated by circular dichroism (CD) and Fourier transform infrared (FT-IR) spectra. The mechanical strength of the "weak" hydrogels is enhanced by the introduction of appropriate suitable amount of AgNO3. Furthermore, the controlled growth of Ag nanoparticles at spatially arranged locations along the nanohelices (hybrid Ag-helical nanomaterial) is readily achieved by UV reduction of Ag (I) ions on the supramolecular helical templates.

  6. Fabrication and experimentation of FRP helical spring

    Science.gov (United States)

    Ekanthappa, J.; Shiva Shankar, G. S.; Amith, B. M.; Gagan, M.

    2016-09-01

    In present scenario, the automobile industry sector is showing increased interest in reducing the unsprung weight of the automobile & hence increasing the fuel Efficiency. One of the feasible sub systems of a vehicle where weight reduction may be attempted is vehicle- suspension system. Usage of composite material is a proven way to lower the component weight without any compromise in strength. The composite materials are having high specific strength, more elastic strain energy storage capacity in comparison with those of steel. Therefore, helical coil spring made of steel is replaceable by composite cylindrical helical coil spring. This research aims at preparing a re-usable mandrel (mould) of Mild steel, developing a setup for fabrication, fabrication of FRP helical spring using continuous glass fibers and Epoxy Resin (Polymer). Experimentation has been conducted on fabricated FRP helical spring to determine its strength parameters & for failure analysis. It is found that spring stiffness (K) of Glass/Epoxy helical-spring is greater than steel-coil spring with reduced weight.

  7. Orbital helical computed tomography in the diagnosis and management of eye trauma; La tomodensitometrie helicoidale dans le diagnostic et la gestion des trauma de l'oeil

    Energy Technology Data Exchange (ETDEWEB)

    Lakits, A.; Prokesch, R.; Scholda, C.; Bankier, A. [Vienna Univ., Dept. of Ophthalmology (Austria)

    2000-07-01

    Helical CT axial scanning with multiplanar reconstruction is accurate at detecting and localizing intraocular and orbital metallic, glass and stone foreign bodies. This imaging method aids the surgeon in choosing the surgical approach to retained intraocular and orbital foreign bodies. (N.C.)

  8. High-resolution CT of otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Dewen, Yang; Kodama, Takao; Tono, Tetsuya; Ochiai, Reiji; Kiyomizu, Kensuke; Suzuki, Yukiko; Yano, Takanori; Watanabe, Katsushi [Miyazaki Medical Coll., Kiyotake (Japan)

    1997-11-01

    High-resolution CT (HRCT) scans of thirty-two patients (60 ears) with the clinical diagnosis of fenestral otosclerosis were evaluated retrospectively. HRCT was performed with 1-mm-thick targeted sections and 1-mm (36 ears) or 0.5-mm (10 ears) intervals in the semiaxial projection. Seven patients (14 ears) underwent helical scanning with a 1-mm slice thickness and 1-mm/sec table speed. Forty-five ears (75%) were found to have one or more otospongiotic or otosclerotic foci on HRCT. In most instances (30 ears), the otospongiotic foci were found in the region of the fissula ante fenestram. No significant correlations between CT findings and air conduction threshold were observed. We found a significant relationship between lesions of the labyrinthine capsule and sensorineural hearing loss. We conclude that HRCT is a valuable modality for diagnosing otosclerosis, especially when otospongiotic focus is detected. (author)

  9. Prediction of acute encephalopathy with biphasic seizures and late reduced diffusion in patients with febrile status epilepticus.

    Science.gov (United States)

    Yokochi, Takaoki; Takeuchi, Takahito; Mukai, Jumpei; Akita, Yukihiro; Nagai, Kojiro; Obu, Keizo; Kakuma, Tatsuyuki; Matsuishi, Toyojiro

    2016-02-01

    Acute encephalopathy with biphasic seizures and late reduced diffusion (AESD) is the most common subtype of acute encephalopathy among children in Japan. The pathogenesis of AESD is mostly delayed cerebral edema caused by excitotoxic injury. It is difficult to discriminate AESD and complex febrile seizure in the early phase. Many cases have neurologic sequelae because early intervention is difficult. To establish an early diagnostic method, we assessed 213 hospitalized cases of febrile status epilepticus (FSE) between January 2004 and August 2014. We categorized FSE cases into an AESD group and a non-AESD group and compared their clinical courses, laboratory data and cranial computed tomography (CT) findings. Of 213 hospitalized FSE cases, 19 (9%) were AESD. Univariate analysis showed that the AESD group took a significantly longer time to wake after FSE, had a higher degree of respiratory acidemia, and higher levels of serum AST, ALT, LD, hyperglycemia and hyperammonemia than the non-AESD group. We developed a scoring model that predicts AESD based on multivariate analysis. Using cut-off points of 4 and more with this scoring model, we could identify the AESD cases with 93% sensitivity and 91% specificity. These scores also had a positive correlation with prognosis. Our scoring model enables early diagnosis of AESD. Patients with high scores should be observed carefully and early intervention should be considered. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  10. Radiation dose in computed tomography of the pelvis: comparison of helical and axial scanning.

    Science.gov (United States)

    Pitman, A G; Budd, R S; McKenzie, A F

    1997-11-01

    An anthropomorphic Rando phantom was used to compare radiation doses sustained during helical and conventional axial CT of the pelvis. The values obtained with the Rando phantom were validated against cadaveric phantoms, and show good agreement. For the authors' particular CT unit, helical scanning was found to deliver a lower radiation dose than conventional axial scanning. This was most prominent at 1.0-s tube rotation times (average dose ratio 1.24). For realistic scanning parameters and exposure factors, the ratio of radiation dose to pelvic organs can be expected to lie in the range of 40-100 mGy. The whole-body effective dose (ED) depends on selection of scanning parameters and patients anatomy. In a favourable case scenario, the ED for CT scanning of the pelvis in a male can be expected to be between 10 and 20 mSv if the scrotum is not included in the radiation field, while the ED in a female will be approximately 20 mSv. An examination of scatter radiation fall-off curves from a single slice shows that the spread of scatter radiation is only marginally affected by slice thickness. A total of 10-12 cm of human soft tissue acts as a good barrier against internal scattered radiation. The use of such scatter fall-off curves, together with manufacturers' dosimetry specifications, allows a fast estimate of absorbed dose.

  11. A biphasic scaffold based on silk and bioactive ceramic with stratified properties for osteochondral tissue regeneration.

    Science.gov (United States)

    Li, Jiao Jiao; Kim, Kyungsook; Roohani-Esfahani, Seyed-Iman; Guo, Jin; Kaplan, David L; Zreiqat, Hala

    2015-07-14

    Significant clinical challenges encountered in the effective long-term treatment of osteochondral defects have inspired advancements in scaffold-based tissue engineering techniques to aid repair and regeneration. This study reports the development of a biphasic scaffold produced via a rational combination of silk fibroin and bioactive ceramic with stratified properties to satisfy the complex and diverse regenerative requirements of osteochondral tissue. Structural examination showed that the biphasic scaffold contained two phases with different pore morphologies to match the cartilage and bone segments of osteochondral tissue, which were joined at a continuous interface. Mechanical assessment showed that the two phases of the biphasic scaffold imitated the load-bearing behaviour of native osteochondral tissue and matched its compressive properties. In vitro testing showed that different compositions in the two phases of the biphasic scaffold could direct the preferential differentiation of human mesenchymal stem cells towards the chondrogenic or osteogenic lineage. By featuring simple and reproducible fabrication and a well-integrated interface, the biphasic scaffold strategy established in this study circumvented the common problems experienced with integrated scaffold designs and could provide an effective approach for the regeneration of osteochondral tissue.

  12. Unusually Stable Helical Coil Allotrope of Phosphorus.

    Science.gov (United States)

    Liu, Dan; Guan, Jie; Jiang, Jingwei; Tománek, David

    2016-12-14

    We have identified an unusually stable helical coil allotrope of phosphorus. Our ab initio density functional theory calculations indicate that the uncoiled, isolated straight one-dimensional chain is equally stable as a monolayer of black phosphorus dubbed phosphorene. The coiling tendency and the attraction between adjacent coil segments add an extra stabilization energy of ∼12 meV/atom to the coil allotrope, similar in value to the ∼16 meV/atom interlayer attraction in bulk black phosphorus. Thus, the helical coil structure is essentially as stable as black phosphorus, the most stable phosphorus allotrope known to date. With an optimum radius of 2.4 nm, the helical coil of phosphorus may fit well and even form inside wide carbon nanotubes.

  13. FLUID FLOW IN ROTATING HELICAL SQUARE DUCTS

    Institute of Scientific and Technical Information of China (English)

    Chen Hua-jun; Zhang Ben-zhao; Zhang Jin-suo

    2003-01-01

    A numerical study is made for a fully developed laminar flow in rotating helical pipes.Due to the rotation, the Coriolis force can also contribute to the secondary flow.The interaction between rotation, torsion, and curvature complicates the flow characteristics.The effects of rotation and torsion on the flow transitions are studied in details.The results show that there are obvious differences between the flow in rotating ducts and in helical ducts without rotation.Certain hitherto unknown flow patterns are found.The effects of rotation and torsion on the friction factor are also examined.Present results show the characteristics of the fluid flow in rotating helical square ducts.

  14. Manipulation of wavefront using helical metamaterials.

    Science.gov (United States)

    Yang, Zhenyu; Wang, Zhaokun; Tao, Huan; Zhao, Ming

    2016-08-01

    Helical metamaterials, a kind of 3-dimensional structure, has relatively strong coupling effect among the helical nano-wires. Therefore, it is expected to be a good candidate for generating phase shift and controlling wavefront with high efficiency. In this paper, using the finite-difference time-domain (FDTD) method, we studied the phase shift properties in the helical metamaterials. It is found that the phase shift occurs for both transmitted and reflected light waves. And the maximum of reflection coefficients can reach over 60%. In addition, the phase shift (φ) is dispersionless in the range of 600 nm to 860 nm, that is, it is only dominated by the initial angle (θ) of the helix. The relationship between them is φ = ± 2θ. Using Jones calculus we give a further explanation for these properties. Finally, by arranging the helixes in an array with a constant phase gradient, the phenomenon of anomalous refraction was also observed in a broad wavelength range.

  15. Nondispersive optical activity of meshed helical metamaterials.

    Science.gov (United States)

    Park, Hyun Sung; Kim, Teun-Teun; Kim, Hyeon-Don; Kim, Kyungjin; Min, Bumki

    2014-11-17

    Extreme optical properties can be realized by the strong resonant response of metamaterials consisting of subwavelength-scale metallic resonators. However, highly dispersive optical properties resulting from strong resonances have impeded the broadband operation required for frequency-independent optical components or devices. Here we demonstrate that strong, flat broadband optical activity with high transparency can be obtained with meshed helical metamaterials in which metallic helical structures are networked and arranged to have fourfold rotational symmetry around the propagation axis. This nondispersive optical activity originates from the Drude-like response as well as the fourfold rotational symmetry of the meshed helical metamaterials. The theoretical concept is validated in a microwave experiment in which flat broadband optical activity with a designed magnitude of 45° per layer of metamaterial is measured. The broadband capabilities of chiral metamaterials may provide opportunities in the design of various broadband optical systems and applications.

  16. Large-scale dynamics of magnetic helicity

    Science.gov (United States)

    Linkmann, Moritz; Dallas, Vassilios

    2016-11-01

    In this paper we investigate the dynamics of magnetic helicity in magnetohydrodynamic (MHD) turbulent flows focusing at scales larger than the forcing scale. Our results show a nonlocal inverse cascade of magnetic helicity, which occurs directly from the forcing scale into the largest scales of the magnetic field. We also observe that no magnetic helicity and no energy is transferred to an intermediate range of scales sufficiently smaller than the container size and larger than the forcing scale. Thus, the statistical properties of this range of scales, which increases with scale separation, is shown to be described to a large extent by the zero flux solutions of the absolute statistical equilibrium theory exhibited by the truncated ideal MHD equations.

  17. A helically distorted MHD flux rope model

    Science.gov (United States)

    Theobald, Michael L.; Montgomery, David

    1990-01-01

    A flux rope model is proposed which has a variable degree of helical distortion from axisymmetry. The basis for this suggestion is a series of numerical and analytical investigations of magnetohydrodynamic states which result when an axial electric current is directed down on dc magnetic field. The helically distorted states involve a flow velocity and seem to be favored because of their lower rate of energy dissipation. Emphasis is on the magnetometer and particle energy analyzer traces that might be characteristic of such flux ropes. It is shown that even a fractionally small helical distortion may considerably alter the traces in minimum-variance coordinates. In short, what may be fairly common MHD processes can render a flux rope almost unrecognizable under standard diagnostics, even if the departures from axisymmetry are not great.

  18. Turbulent dynamo with advective magnetic helicity flux

    CERN Document Server

    Del Sordo, Fabio; Brandenburg, Axel

    2012-01-01

    Many astrophysical bodies harbor magnetic fields that are thought to be sustained by dynamo processes. However, it has been argued that the production of large-scale magnetic fields by a mean-field dynamo is strongly suppressed at large magnetic Reynolds numbers owing to the conservation of magnetic helicity. This phenomenon is known as catastrophic quenching. Advection of magnetic field toward the outer boundaries and away from the dynamo is expected to alleviate such quenching. Examples are stellar and galactic winds. Such advection might be able to overcome the constraint imposed by the conservation of magnetic helicity, transporting a fraction of it outside the domain in which the dynamo operates. We study how the dynamo process is affected by advection. In particular, we study the relative roles played by advective and diffusive fluxes of magnetic helicity. We do this by performing direct numerical simulations of a turbulent dynamo of alpha^2 type driven by forced turbulence in a Cartesian domain in the ...

  19. Metallofoldamers supramolecular architectures from helicates to biomimetics

    CERN Document Server

    Maayan, Galia

    2013-01-01

    Metallofoldamers are oligomers that fold into three-dimensional structures in a controlled manner upon coordination with metal ions. Molecules in this class have shown an impressive ability to form single-handed helical structures and other three-dimensional architectures. Several metallofoldamers have been applied as sensors due to their selective folding when binding to a specific metal ion, while others show promise for applications as responsive materials on the basis of their ability to fold and unfold upon changes in the oxidation state of the coordinated metal ion, and as novel catalysts. Metallofoldamers: From Helicates to Biomimetic Architectures describes the variety of interactions between oligomers and metal species, with a focus on non-natural synthetic molecules. Topics covered include: the major classes of foldamers and their folding driving force metalloproteins and metalloenzymes helicates: self-assembly, structure and applications abiotic metallo-DNA metallo-PNA and iDNA metallopeptides inte...

  20. The helical structure of DNA facilitates binding

    Science.gov (United States)

    Berg, Otto G.; Mahmutovic, Anel; Marklund, Emil; Elf, Johan

    2016-09-01

    The helical structure of DNA imposes constraints on the rate of diffusion-limited protein binding. Here we solve the reaction-diffusion equations for DNA-like geometries and extend with simulations when necessary. We find that the helical structure can make binding to the DNA more than twice as fast compared to a case where DNA would be reactive only along one side. We also find that this rate advantage remains when the contributions from steric constraints and rotational diffusion of the DNA-binding protein are included. Furthermore, we find that the association rate is insensitive to changes in the steric constraints on the DNA in the helix geometry, while it is much more dependent on the steric constraints on the DNA-binding protein. We conclude that the helical structure of DNA facilitates the nonspecific binding of transcription factors and structural DNA-binding proteins in general.

  1. Demonstration of steady inductive helicity injection

    Science.gov (United States)

    Sieck, P. E.; Jarboe, T. R.; Izzo, V. A.; Hamp, W. T.; Nelson, B. A.; O'Neill, R. G.; Redd, A. J.; Smith, R. J.

    2006-02-01

    Initial results demonstrating the concept of constant inductive helicity injection are presented. Constant helicity injection is achieved using two oscillating inductive helicity injectors, with the goal of producing a bow tie spheromak. Each injector is a 180° segment of a reverse field pinch and they are driven 90° out of phase. Approximately 5 MW of power is injected during the 6 ms pulse, and the input power has been maintained at a fairly constant value by directly fuelling the injectors with neutral gas. Motivation for the experiment is given, including beta-limit calculations for the bow tie spheromak. Fuelling the injectors with neutral gas during the discharge is shown to produce injector parameters that are more constant in time. A series of discharges with increasing power input shows a promising increase in toroidal current. Unique construction techniques of the experiment are also described.

  2. 儿童先天性漏斗胸与胸廓扁平程度相关性的多层螺旋CT研究%Relationship of the degree of the congenital pectus excavatum and the flat chest in children:evaluation with multislice helical CT

    Institute of Scientific and Technical Information of China (English)

    路涛; 邓开鸿

    2012-01-01

    目的 评价儿童先天性漏斗胸并发扁平胸的多层螺旋CT表现及其相关性.方法 收集2011年2~10月经临床诊断并行CT检查的漏斗胸患儿34例,在PACS形态图像上,测量漏斗胸的胸骨凹陷深度、Haller指数、CT凹陷指数及胸廓扁平指数,评价它们之间的关系.结果 34例先天性漏斗胸患儿胸骨凹陷深度为(17.12±9.98)mm,Haller指数为4.12±1.48,CT凹陷指数为2.39±0.70,胸廓扁平指数为3.30±0.56.漏斗胸中重度患儿的胸骨凹陷深度及胸廓扁平指数与轻度患儿相比较,差异具有统计学意义,且胸骨凹陷深度、胸廓扁平指数分别与Haller指数、CT凹陷指数间存在正相关关系.不同年龄组间患儿的胸骨凹陷深度、Haller指数、CT凹陷指数、胸廓扁平指数比较,差异均无统计学意义.结论 随着漏斗胸程度的加重,胸骨凹陷深度和胸廓扁平程度增加,其次漏斗胸的严重程度、胸骨凹陷深度及胸廓扁平程度并不随着年龄增长而加重.%Objective To evaluate the CT manifestations of pectus excavatum accompanied by flat chest and their relativity. Methods CT features of 34 children with pectus excavatum were retrospectively reviewed. The sternal depression(SD) ,Haller index(HI) ,CT depression index(CTDI) ,chest flat index( CFI) were measured from the images on the PACS system. The relationships among these indexes were evaluated. Results The SD was( 17. 12 ±9. 98) mm, HI was 4. 12 ±1.48,CT DI was 2.39 ±0.70, CFI was 3. 30 ±0. 56. There were statistical significance of sternal depression and chest flat index between children with modest to severe and slight pectus excavatum. AT the same time, the sternal depression and chest flat index were positively related to the Haller index and CT depression index respectively. There weren't statistical significances of SD, HI, CTDI and CFI among different age groups. Conclusions The degree of sternal depression and flat chest increased with the severity

  3. Current helicity and electromotive force of magnetoconvection influenced by helical background fields

    CERN Document Server

    Ruediger, Guenther

    2016-01-01

    Motivated by the empirical finding that the known hemispheric rules for the current helicity at the solar surface are not strict, the excitation of small-scale current helicity by the influence of a large-scale helical magnetic background fields on nonrotating magnetoconvection is demonstrated. It is shown within a quasilinear analytic theory of driven turbulence and by nonlinear simulations of magnetoconvection that the resulting small-scale current helicity has the same sign as the large-scale current helicity while the ratio of both pseudo-scalars is of the order of the magnetic Reynolds number of the convection. The same models do not provide finite values of the small-scale kinetic helicity. On the other hand, a turbulence-induced electromotive force is produced including the diamagnetic pumping term as well as the eddy diffusivity but no alpha effect. It is thus argued that the relations by Pouquet & Patterson (1978) and Keinigs (1983) for the simultaneous existence of small-scale current helicity a...

  4. Statistical mechanics of double-helical polymers.

    Science.gov (United States)

    De Col, Alvise; Liverpool, Tanniemola B

    2004-06-01

    We introduce a simple geometric model for a double-stranded and double-helical polymer. We study the statistical mechanics of such polymers using both analytical techniques and simulations. Our model has a single energy scale which determines both the bending and twisting rigidity of the polymer. The helix melts at a particular temperature T(c) below which the chain has a helical structure and above which this structure is disordered. Under extension we find that for small forces, the behavior is very similar to wormlike chain behavior but becomes very different at higher forces.

  5. Helicity and nuclear $\\beta$ decay correlations

    CERN Document Server

    Hong, Ran; García, Alejandro

    2016-01-01

    We present simple derivations of nuclear $\\beta$-decay correlations with an emphasis on the special role of helicity. This provides a good opportunity to teach students about helicity and chirality in particle physics through exercises using simple aspects of quantum mechanics. In addition, this paper serves as an introduction to nuclear $\\beta$-decay correlations from both a theoretical and experimental vantage. This article can be used to introduce students to ongoing experiments searching for hints of new physics in the low-energy precision frontier.

  6. Helicity and nuclear β decay correlations

    Science.gov (United States)

    Hong, Ran; Sternberg, Matthew G.; Garcia, Alejandro

    2017-01-01

    We present simple derivations of nuclear β-decay correlations with an emphasis on the special role of helicity. This topic provides a good opportunity to teach students about helicity and chirality in particle physics with exercises that use simple aspects of quantum mechanics. In addition, this paper serves as an introduction to nuclear β-decay correlations from both a theoretical and experimental perspective. This article can be used to introduce students to ongoing experiments searching for hints of new physics in the low-energy precision frontier.

  7. Helicity separation in Heavy-Ion Collisions

    CERN Document Server

    Baznat, Mircea; Sorin, Alexander; Teryaev, Oleg

    2013-01-01

    We study the P-odd effects related to the vorticity of the medium formed in noncentral heavy ion collisions. Using the kinetic Quark-Gluon Strings Model we perform the numerical simulations of the vorticity and hydrodynamical helicity for the various atomic numbers, energies and centralities. We observed the vortical structures typically occupying the relatively small fraction of the fireball volume. In the course of numerical simulations the noticeable hydrodanamical helicity was observed manifesting the specific mirror behaviour with respect to the reaction plane. The effect is maximal at the NICA and FAIR energy range.

  8. New frontiers in CT imaging of airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine [Department of Radiology, University Pierre et Marie Curie, Paris (France); Fetita, Catalin; Preteux, Francoise [Institut National des Telecommunications, Department ARTEMIS, Evry (France); Brauner, Michel W. [Avicenne Hospital, UFR SMBH Paris XIII, Bobigny (France); Lenoir, Stephane [Institut Mutualiste Montsouris, Paris (France)

    2002-05-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  9. Conversion from mutual helicity to self-helicity observed with IRIS

    Science.gov (United States)

    Li, L. P.; Peter, H.; Chen, F.; Zhang, J.

    2014-10-01

    Context. In the upper atmosphere of the Sun observations show convincing evidence for crossing and twisted structures, which are interpreted as mutual helicity and self-helicity. Aims: We use observations with the new Interface Region Imaging Spectrograph (IRIS) to show the conversion of mutual helicity into self-helicity in coronal structures on the Sun. Methods: Using far UV spectra and slit-jaw images from IRIS and coronal images and magnetograms from SDO, we investigated the evolution of two crossing loops in an active region, in particular, the properties of the Si IV line profile in cool loops. Results: In the early stage two cool loops cross each other and accordingly have mutual helicity. The Doppler shifts in the loops indicate that they wind around each other. As a consequence, near the crossing point of the loops (interchange) reconnection sets in, which heats the plasma. This is consistent with the observed increase of the line width and of the appearance of the loops at higher temperatures. After this interaction, the two new loops run in parallel, and in one of them shows a clear spectral tilt of the Si IV line profile. This is indicative of a helical (twisting) motion, which is the same as to say that the loop has self-helicity. Conclusions: The high spatial and spectral resolution of IRIS allowed us to see the conversion of mutual helicity to self-helicity in the (interchange) reconnection of two loops. This is observational evidence for earlier theoretical speculations. Movie associated with Fig. 1 and Appendix A are available in electronic form at http://www.aanda.org

  10. Eikonal slant helices and eikonal Darboux helices in 3-dimensional pseudo-Riemannian manifolds

    OpenAIRE

    Önder, Mehmet; Ziplar, Evren

    2013-01-01

    In this study, we give definitions and characterizations of eikonal slant helices, eikonal Darboux helices and non-normed eikonal Darboux helices in 3-dimensional pseudo- Riemannian manifold M . We show that every eikonal slant helix is also an eikonal Darboux helix for timelike and spacelike curves. Furthermore, we obtain that if the non-null curve a is a non-normed eikonal Darboux helix, then a is an eikonal slant helix if and only if 2 2 e 3k +e1t = constant, where k and t are curvature an...

  11. Bi-phasic Simulation of Metal Injection Moulding:Constitutive Determinations

    Institute of Scientific and Technical Information of China (English)

    Liu Baosheng(柳葆生); Barriere Thierry; Gelin Jean-Claude

    2003-01-01

    To predict the segregation effect in metal injection moulding (MIM) injection, a bi-phasic model based on mixture theory is adopted in simulation. An explicit algorithm is developed and realized by the authors, which conducts the simulation to be a cost-effective tool in MIM technology. In case of the bi-phasic simulation, the viscosity behaviours are necessary to be determined for the flows of each phase while only the viscosity of mixture is measurable by tests. It is a crucial problem for application of the bi-phasic simulation of MIM injection. A reasonable method is hence analysed and proposed to determine the viscosity behaviours of each phase. Even though this method may be furthermore modified in the future, it results in the practical simulation of segregation effects with reasonable parameters. The simulation results are compared with the measurements on injected specimens.

  12. Apomorphine-induced biphasic circling behaviour in 6-hydroxydopamine-lesioned rats. A pharmacological kindling phenomenon.

    Science.gov (United States)

    Coward, D M

    1983-06-01

    Factors governing the development of apomorphine-induced biphasic circling behaviour in rats having unilateral 6-hydroxydopamine lesions of the substantia nigra were investigated. It was found that a post-lesion time of at least 2--3 weeks and the repeated exposure to apomorphine were essential for its development. Optimal results were obtained when animals received weekly apomorphine, 0.05 mg/kg sc, in post-lesion weeks 6, 7 and 8. Pretreatment with haloperidol, 1.0 and 2.0 mg/kg ip 1 h beforehand in post-lesion week 9, converted the biphasic response into an enhanced, uniphasic one. The findings suggest that the development of the biphasic response to apomorphine is a multi-factorial process representing a pharmacological kindling phenomenon.

  13. Shock-induced termination of reentrant cardiac arrhythmias: Comparing monophasic and biphasic shock protocols

    Energy Technology Data Exchange (ETDEWEB)

    Bragard, Jean, E-mail: jbragard@unav.es; Simic, Ana; Elorza, Jorge [Department of Physics and Applied Math., University of Navarra, Pamplona (Spain); Grigoriev, Roman O.; Fenton, Flavio H. [School of Physics, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Cherry, Elizabeth M. [School of Mathematical Sciences, Rochester Institute of Technology, Rochester, New York 14623 (United States); Gilmour, Robert F. [University of Prince Edward Island, Charlottetown C1A 4P3 (Canada); Otani, Niels F. [School of Mathematical Sciences, Rochester Institute of Technology, Rochester, New York 14623 (United States); Department of Biomedical Sciences, Cornell University, Ithaca, New York 14853 (United States)

    2013-12-15

    In this article, we compare quantitatively the efficiency of three different protocols commonly used in commercial defibrillators. These are based on monophasic and both symmetric and asymmetric biphasic shocks. A numerical one–dimensional model of cardiac tissue using the bidomain formulation is used in order to test the different protocols. In particular, we performed a total of 4.8 × 10{sup 6} simulations by varying shock waveform, shock energy, initial conditions, and heterogeneity in internal electrical conductivity. Whenever the shock successfully removed the reentrant dynamics in the tissue, we classified the mechanism. The analysis of the numerical data shows that biphasic shocks are significantly more efficient (by about 25%) than the corresponding monophasic ones. We determine that the increase in efficiency of the biphasic shocks can be explained by the higher proportion of newly excited tissue through the mechanism of direct activation.

  14. Therapeutic efficacy of endostatin exhibits a biphasic dose-response curve.

    Science.gov (United States)

    Celik, Ilhan; Sürücü, Oguzkan; Dietz, Carsten; Heymach, John V; Force, Jeremy; Höschele, Iris; Becker, Christian M; Folkman, Judah; Kisker, Oliver

    2005-12-01

    We show here that recombinant endostatin protein has a biphasic effect on the inhibition of endothelial cell migration in vitro. In tumor-bearing animals, there is a similar biphasic effect on the inhibition of tumor growth and on circulating endothelial cells after once-daily s.c. injections. This biphasic effect is revealed as a U-shaped curve in which efficacy is optimal between very low and very high doses depending on the tumor type. This result may be applicable to other inhibitors of endothelial growth and to angiogenesis. Furthermore, these results have important implications for clinicians who administer angiogenesis inhibitors for cancer or other angiogenesis-dependent diseases. When these results are taken together with two previous reports of angiogenesis inhibitors with a U-shaped dose-response, they suggest that other regulators of endothelial growth may display a similar pattern.

  15. Biphasic Dependence of Glioma Survival and Cell Migration on CD44 Expression Level.

    Science.gov (United States)

    Klank, Rebecca L; Decker Grunke, Stacy A; Bangasser, Benjamin L; Forster, Colleen L; Price, Matthew A; Odde, Thomas J; SantaCruz, Karen S; Rosenfeld, Steven S; Canoll, Peter; Turley, Eva A; McCarthy, James B; Ohlfest, John R; Odde, David J

    2017-01-03

    While several studies link the cell-surface marker CD44 to cancer progression, conflicting results show both positive and negative correlations with increased CD44 levels. Here, we demonstrate that the survival outcomes of genetically induced glioma-bearing mice and of high-grade human glioma patients are biphasically correlated with CD44 level, with the poorest outcomes occurring at intermediate levels. Furthermore, the high-CD44-expressing mesenchymal subtype exhibited a positive trend of survival with increased CD44 level. Mouse cell migration rates in ex vivo brain slice cultures were also biphasically associated with CD44 level, with maximal migration corresponding to minimal survival. Cell simulations suggest that cell-substrate adhesiveness is sufficient to explain this biphasic migration. More generally, these results highlight the potential importance of non-monotonic relationships between survival and biomarkers associated with cancer progression.

  16. Dissolved nutrients and atrazine removal by column-scale monophasic and biphasic rain garden model systems.

    Science.gov (United States)

    Yang, Hanbae; McCoy, Edward L; Grewal, Parwinder S; Dick, Warren A

    2010-08-01

    Rain gardens are bioretention systems that have the potential to reduce peak runoff flow and improve water quality in a natural and aesthetically pleasing manner. We compared hydraulic performance and removal efficiencies of nutrients and atrazine in a monophasic rain garden design versus a biphasic design at a column-scale using simulated runoff. The biphasic rain garden was designed to increase retention time and removal efficiency of runoff pollutants by creating a sequence of water saturated to unsaturated conditions. We also evaluated the effect of C substrate availability on pollutant removal efficiency in the biphasic rain garden. Five simulated runoff events with various concentrations of runoff pollutants (i.e. nitrate, phosphate, and atrazine) were applied to the monophasic and biphasic rain gardens once every 5d. Hydraulic performance was consistent over the five simulated runoff events. Peak flow was reduced by approximately 56% for the monophasic design and 80% for the biphasic design. Both rain garden systems showed excellent removal efficiency of phosphate (89-100%) and atrazine (84-100%). However, significantly (p<0.001) higher removal of nitrate was observed in the biphasic (42-63%) compared to the monophasic rain garden (29-39%). Addition of C substrate in the form of glucose increased removal efficiency of nitrate significantly (p<0.001), achieving up to 87% removal at a treatment C/N ratio of 2.0. This study demonstrates the importance of retention time, environmental conditions (i.e. saturated/unsaturated conditions), and availability of C substrate for bioremediation of pollutants, especially nitrates, in rain gardens.

  17. Usefulness and problems of three-dimensional CT (3D-CT) in the neurosurgical patients

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Kousaku; Tajitsu, Kenichiro; Ichitsubo, Hidenori [Kaseda Hospital, Kagoshima (Japan); Moriya, Nobuhide; Kadota, Koki; Asakura, Tetsuhiko

    1997-11-01

    Helical CT scanning is a new technique that can uninterruptedly generate a volume of data. The data thus acquired with or without contrast medium is reconstructed for three-dimensional CT (3D-CT) or three-dimensional CT angiography (3D-CTA). The authors have studied 36 aneurysms, 11 aterosclerotic lesions, 16 tumors and 14 traumatic lesions in more than 60 patients with 3D-CT or 3D-CTA. Aneurysm is visualized clearly on 3D-CTA. The ability to rotate images in all planes aids in showing the aneurysm neck and dome, parent artery and surrounding bony structures. 3D-CTA can assist the surgeon in the approach to the aneurysm. Imaging of the infraclinoid portion of the internal carotid artery may be inadequate with 3D-CTA because of contrast enhancement of the cavernous sinus and the anterior portion of the lesser sphenoid wing. Stenosis or occlusion of the circle of Willis and the common carotid artery bifurcation is well identified on 3D-CTA. It is noted that 3D-CTA delineates inaccurately stenosis severity because of partial volume effects, the threshold level and the timing of scanning. Well-enhanced brain tumors such as meningioma are demonstrated clearly. The relationship of the tumor to surrounding major arteries and bony structures is well defined on enhanced 3D-CT. Marked transposition of skull fracture by head trauma is shown distinctly on 3D-CT. In conclusion, although this technique requires further development and clinical evaluation, the authors` experience with 3D-CT and 3D-CTA suggests that this may become a valuable tool in the diagnosis of neurosurgical patients. (author)

  18. Usefulness of 3D-image of ossicles with helical scanning

    Energy Technology Data Exchange (ETDEWEB)

    Makihata, Hiroshi; Kimura, Hideaki; Hanaguri, Katsurou; Fukushima, Noriyuki; Oda, Yukari [Chugoku Rousai Hospital, Kure, Hiroshima (Japan)

    1995-09-01

    It is important to understand the abnormalities of ossicles (continuity, destruction and malformation) in clinical practice of middle ear diseases. Multidirection exposures were needed to visualize ossicles with the conventional CT scanning, because they are visualized in 2D images. It was difficult to make patients hold the posture and to settle the problems such as an increase in X-ray dose. We created 3D images of ossicles with a helical scanning, and examined the visualization of the normal and abnormal ear (otitis media cholesteatoma) especially in terms of continuity in each of 20 patients. We would here like to report the favorable results together with some literature review. (author).

  19. Energy and helicity budgets of solar quiet regions

    CERN Document Server

    Tziotziou, K; Georgoulis, M K; Kontogiannis, I

    2014-01-01

    We investigate the free magnetic energy and relative magnetic helicity budgets of solar quiet regions. Using a novel non-linear force-free method requiring single solar vector magnetograms we calculate the instantaneous free magnetic energy and relative magnetic helicity budgets in 55 quiet-Sun vector magnetograms. As in a previous work on active regions, we construct here for the first time the (free) energy-(relative) helicity diagram of quiet-Sun regions. We find that quiet-Sun regions have no dominant sense of helicity and show monotonic correlations a) between free magnetic energy/relative helicity and magnetic network area and, consequently, b) between free magnetic energy and helicity. Free magnetic energy budgets of quiet-Sun regions represent a rather continuous extension of respective active-region budgets towards lower values, but the corresponding helicity transition is discontinuous due to the incoherence of the helicity sense contrary to active regions. We further estimate the instantaneous free...

  20. Helical mode interactions and spectral transfer processes in magnetohydrodynamic turbulence

    CERN Document Server

    Linkmann, Moritz F; McKay, Mairi E; Jäger, Julia

    2015-01-01

    Spectral transfer processes in magnetohydrodynamic (MHD) turbulence are investigated analytically by decomposition of the velocity and magnetic fields in Fourier space into helical modes. Steady solutions of the dynamical system which governs the evolution of the helical modes are determined, and a stability analysis of these solutions is carried out. The interpretation of the analysis is that unstable solutions lead to energy transfer between the interacting modes while stable solutions do not. From this, a dependence of possible interscale energy and helicity transfers on the helicities of the interacting modes is derived. As expected from the inverse cascade of magnetic helicity in 3D MHD turbulence, mode interactions with like helicities lead to transfer of energy and magnetic helicity to smaller wavenumbers. However, some interactions of modes with unlike helicities also contribute to an inverse energy transfer. As such, an inverse energy cascade for nonhelical magnetic fields is shown to be possible. Fu...

  1. Diagnosis of coronary artery disease. Current status of CT; Diagnostik der koronaren Herzkrankheit. Aktueller Stand der CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Martin H.K.; Klass, O.; Brunner, H. [Klinik fuer Diagnostische und Interventionelle Radiologie, Unikliniken Ulm (Germany)

    2010-06-15

    Continuous technical innovations during the last years have established cardiac CT as a modality for noninvasive coronary angiography in clinical routine. 64 detector row generations and beyond have shown high diagnostic accuracy for obstructive stenosis detection in comparison to the standard of reference catheterization angiography. But the high radiation dose exposure associated with helical cardiac CT acquisition has sparked increasing concern in the medical community. The issue has been addressed with the newest releases of technology. Dose reduction by 80% and more is achieved with modified scan techniques rendering the method suitable for clinical routine. Symptomatic patients with an intermediate pre-test probability have been identified as the most suitable candidates for CT coronary angiography. Other appropriate indications include the rapid assessment of bypass grafts and suspected coronary anomalies. CT coronary angiography has been shown to be cost effective for the evaluation of patients with acute chest pain in the emergency department. But CT is able to provide more than coronary morphology, initial feasibility testing has shown that CT first-pass myocardial imaging can visualize perfusion defects with adenosine induced vasodilatation. Coronary morphology and functional perfusion studies have been shown to be complementary providing incremental diagnostic value over either technique alone. In the next few years a lot of comparison trials will establish the best suitable perfusion method (SPECT, MRI or CT) for hybrid imaging with CT coronary angiography. (orig.)

  2. Paired associative stimulation targeting the tibialis anterior muscle using either mono or biphasic transcranial magnetic stimulation

    DEFF Research Database (Denmark)

    Mrachacz-Kersting, Natalie; Stevenson, Andrew James Thomas

    2017-01-01

    a reduced intensity of this pulse would lead to significant changes as has been reported for hand muscles using a monophasic TMS pulse. Three interventions were investigated: (1) suprathreshold PAbi-PAS (n = 11); (2) suprathreshold PAmono-PAS (n = 11) where PAS was applied using a biphasic or monophasic......Paired associative stimulation (PAS) protocols induce plastic changes within the motor cortex. The objectives of this study were to investigate PAS effects targeting the tibialis anterior (TA) muscle using a biphasic transcranial magnetic stimulation (TMS) pulse form and, to determine whether...

  3. Biphasic decay of the Ca transient results from increased sarcoplasmic reticulum Ca leak

    Science.gov (United States)

    Sankaranarayanan, Rajiv; Li, Yatong; Greensmith, David J.; Eisner, David A.

    2016-01-01

    Key points Ca leak from the sarcoplasmic reticulum through the ryanodine receptor (RyR) reduces the amplitude of the Ca transient and slows its rate of decay.In the presence of β‐adrenergic stimulation, RyR‐mediated Ca leak produces a biphasic decay of the Ca transient with a fast early phase and a slow late phase.Two forms of Ca leak have been studied, Ca‐sensitising (induced by caffeine) and non‐sensitising (induced by ryanodine) and both induce biphasic decay of the Ca transient.Only Ca‐sensitising leak can be reversed by traditional RyR inhibitors such as tetracaine.Ca leak can also induce Ca waves. At low levels of leak, waves occur. As leak is increased, first biphasic decay and then slowed monophasic decay is seen. The level of leak has major effects on the shape of the Ca transient. Abstract In heart failure, a reduction in Ca transient amplitude and contractile dysfunction can by caused by Ca leak through the sarcoplasmic reticulum (SR) Ca channel (ryanodine receptor, RyR) and/or decreased activity of the SR Ca ATPase (SERCA). We have characterised the effects of two forms of Ca leak (Ca‐sensitising and non‐sensitising) on calcium cycling and compared with those of SERCA inhibition. We measured [Ca2+]i with fluo‐3 in voltage‐clamped rat ventricular myocytes. Increasing SR leak with either caffeine (to sensitise the RyR to Ca activation) or ryanodine (non‐sensitising) had similar effects to SERCA inhibition: decreased systolic [Ca2+]i, increased diastolic [Ca2+]i and slowed decay. However, in the presence of isoproterenol, leak produced a biphasic decay of the Ca transient in the majority of cells while SERCA inhibition produced monophasic decay. Tetracaine reversed the effects of caffeine but not of ryanodine. When caffeine (1 mmol l−1) was added to a cell which displayed Ca waves, the wave frequency initially increased before waves disappeared and biphasic decay developed. Eventually (at higher caffeine concentrations), the

  4. Synthesis of stabilized alpha-helical peptides.

    Science.gov (United States)

    Bernal, Federico; Katz, Samuel G

    2014-01-01

    Stabilized alpha-helical (SAH) peptides are valuable laboratory tools to explore important protein-protein interactions. Whereas most peptides lose their secondary structure when isolated from the host protein, stapled peptides incorporate an all-hydrocarbon "staple" that reinforces their natural alpha-helical structure. Thus, stapled peptides retain their functional ability to bind their native protein targets and serve multiple experimental uses. First, they are useful for structural studies such as NMR or crystal structures that map and better define binding sites. Second, they can be used to identify small molecules that specifically target that interaction site. Third, stapled peptides can be used to test the importance of specific amino acid residues or posttranslational modifications to the binding. Fourth, they can serve as structurally competent bait to identify novel binding partners to specific alpha-helical motifs. In addition to markedly improved alpha-helicity, stapled peptides also display resistance to protease cleavage and enhanced cell permeability. Most importantly, they are useful for intracellular experiments that explore the functional consequences of blocking particular protein interactions. Because of their remarkable stability, stapled peptides can be applied to whole-animal, in vivo studies. Here we describe a protocol for the synthesis of a peptide that incorporates an all-hydrocarbon "staple" employing a ring-closing olefin metathesis reaction. With proper optimization, stapled peptides can be a fundamental, accurate laboratory tool in the modern chemical biologist's armory.

  5. LAMINAR FLUID FLOW IN HELICAL ELLIPTICAL PIPE

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    In this paper, using an orthogonal curvilinear coordinate system and solving the complete N-S equations, we analyzed the flow in a helical elliptical duct by the perturbation method. The first-order solutions of the stream function Ψ, axial velocity w and the velocity of secondary flow (u, v) were obtained. The effects of torsion, curvature and the axial pressure gradient on the secondary flow were discussed in detail. The study indicates that the torsion has first-order effect on the secondary flow in a helical elliptical pipe, the secondary flow is dominated by torsion when the axial pressure gradient is small and for increasing gradient the secondary flow is eventually dominated by the effect due to curvature. The fact that the torsion has no effect on fluid flow in a helical pipe with a circular cross section was also confirmed. The most important conclusion is that the flow in a helical elliptical pipe to the first-order can be obtained as a combination of the flow in a toroidal pipe and the flow in a twisted pipe.

  6. On statistical equilibrium in helical fluid flows

    Directory of Open Access Journals (Sweden)

    M. V. Kurgansky

    2006-01-01

    Full Text Available The statistical mechanics of 3-D helical flows is re-examined for a continuum truncated at a top wavenumber. Based on the principle of equipartition of the flow enstrophy between helical modes, the emerging (i energy spectrum law '–2' and (ii formal mathematical analogy between the helicity and the thermodynamic entropy are discussed. It is noted that the '–2' scaling law is consistent with both spectral equilibrium and spectral cascade paradigms. In an attempt to apply the obtained results to a turbulent flow regime within the Earth's outer liquid core, where the net helicity of a turbulent flow component is presumably explained by Earth's rotation, it has been noticed that it is the energy spectral law '–1', but not '–2', which is likely realized there and within the logarithmic accuracy corresponds to the case of the velocity structure function [u(l]2 independency on the spatial scale l, the latter is consistent with observations. It is argued that the '–1' scaling law can also be interpreted in terms of the spectral equilibrium and it is emphasized that the causes of the likely dominance of the spectral law '–1' over the spectral law '–2' in this geophysical application deserve further investigation and clarification.

  7. Coulomb drag between helical Luttinger liquids

    Science.gov (United States)

    Kainaris, N.; Gornyi, I. V.; Levchenko, A.; Polyakov, D. G.

    2017-01-01

    We theoretically study Coulomb drag between two helical edges with broken spin-rotational symmetry, such as would occur in two capacitively coupled quantum spin Hall insulators. For the helical edges, Coulomb drag is particularly interesting because it specifically probes the inelastic interactions that break the conductance quantization for a single edge. Using the kinetic equation formalism, supplemented by bosonization, we find that the drag resistivity ρD exhibits a nonmonotonic dependence on the temperature T . In the limit of low T ,ρD vanishes with decreasing T as a power law if intraedge interactions are not too strong. This is in stark contrast to Coulomb drag in conventional quantum wires, where ρD diverges at T →0 irrespective of the strength of repulsive interactions. Another unusual property of Coulomb drag between the helical edges concerns higher T for which, unlike in the Luttinger liquid model, drag is mediated by plasmons. The special type of plasmon-mediated drag can be viewed as a distinguishing feature of the helical liquid—because it requires peculiar umklapp scattering only available in the presence of a Dirac point in the electron spectrum.

  8. Helical Gears Modified To Decrease Transmission Errors

    Science.gov (United States)

    Handschuh, R. F.; Coy, J. J.; Litvin, F. L.; Zhang, J.

    1993-01-01

    Tooth surfaces of helical gears modified, according to proposed design concept, to make gears more tolerant of misalignments and to improve distribution of contact stresses. Results in smaller transmission errors, with concomitant decreases in vibrations and noise and, possibly, increases in service lives.

  9. Helical Ordering in Chiral Block Copolymers

    Science.gov (United States)

    Zhao, Wei; Hong, Sung Woo; Chen, Dian; Grason, Gregory; Russell, Thomas

    2012-02-01

    Introducing molecular chirality into the segments of block copolymers can influence the nature of the resultant morphology. Such an effect was found for poly(styrene-b-L-lactide) (PS-b-PLLA) diblock copolymers where hexagonally packed PLLA helical microdomains (H* phase) form in a PS matrix. However, molecular ordering of PLLA within the helical microdomains and the transfer of chirality from the segmental level to the mesoscale is still not well understood. We developed a field theoretic model to describe the interactions between segments of chiral blocks, which have the tendency to form a ``cholesteric'' texture. Based on the model, we calculated the bulk morphologies of chiral AB diblock copolymers using self-consistent field theory (SCFT). Experiments show that the H* phase only forms when microphase separation between PS and PLLA block happens first and crystallization of PLLA block is suppressed or happens within confined microdomain. Hence, crystalline ordering is not necessary for H* phase formation. The SCFT offers the chance to explore the range of thermodynamic stability of helical structures in the phase diagram of chiral block copolymer melts, by tuning parameters not only like the block segregation strength and composition, but also new parameters such as the ratio between preferred helical pitch to the radius of gyration and the Frank elastic constant for inter-segment distortions.

  10. Magnetic stripes and skyrmions with helicity reversals.

    Science.gov (United States)

    Yu, Xiuzhen; Mostovoy, Maxim; Tokunaga, Yusuke; Zhang, Weizhu; Kimoto, Koji; Matsui, Yoshio; Kaneko, Yoshio; Nagaosa, Naoto; Tokura, Yoshinori

    2012-06-05

    It was recently realized that topological spin textures do not merely have mathematical beauty but can also give rise to unique functionalities of magnetic materials. An example is the skyrmion--a nano-sized bundle of noncoplanar spins--that by virtue of its nontrivial topology acts as a flux of magnetic field on spin-polarized electrons. Lorentz transmission electron microscopy recently emerged as a powerful tool for direct visualization of skyrmions in noncentrosymmetric helimagnets. Topologically, skyrmions are equivalent to magnetic bubbles (cylindrical domains) in ferromagnetic thin films, which were extensively explored in the 1970s for data storage applications. In this study we use Lorentz microscopy to image magnetic domain patterns in the prototypical magnetic oxide-M-type hexaferrite with a hint of scandium. Surprisingly, we find that the magnetic bubbles and stripes in the hexaferrite have a much more complex structure than the skyrmions and spirals in helimagnets, which we associate with the new degree of freedom--helicity (or vector spin chirality) describing the direction of spin rotation across the domain walls. We observe numerous random reversals of helicity in the stripe domain state. Random helicity of cylindrical domain walls coexists with the positional order of magnetic bubbles in a triangular lattice. Most unexpectedly, we observe regular helicity reversals inside skyrmions with an unusual multiple-ring structure.

  11. Muon Beam Helical Cooling Channel Design

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland; Ankenbrandt, Charles; Flanagan, G; Kazakevich, G M; Marhauser, Frank; Neubauer, Michael; Roberts, T; Yoshikawa, C; Derbenev, Yaroslav; Morozov, Vasiliy; Kashikhin, V S; Lopes, Mattlock; Tollestrup, A; Yonehara, Katsuya; Zloblin, A

    2013-06-01

    The Helical Cooling Channel (HCC) achieves effective ionization cooling of the six-dimensional (6d) phase space of a muon beam by means of a series of 21st century inventions. In the HCC, hydrogen-pressurized RF cavities enable high RF gradients in strong external magnetic fields. The theory of the HCC, which requires a magnetic field with solenoid, helical dipole, and helical quadrupole components, demonstrates that dispersion in the gaseous hydrogen energy absorber provides effective emittance exchange to enable longitudinal ionization cooling. The 10-year development of a practical implementation of a muon-beam cooling device has involved a series of technical innovations and experiments that imply that an HCC of less than 300 m length can cool the 6d emittance of a muon beam by six orders of magnitude. We describe the design and construction plans for a prototype HCC module based on oxygen-doped hydrogen-pressurized RF cavities that are loaded with dielectric, fed by magnetrons, and operate in a superconducting helical solenoid magnet.

  12. Artificial, parallel, left-handed DNA helices.

    Science.gov (United States)

    Tian, Cheng; Zhang, Chuan; Li, Xiang; Li, Yingmei; Wang, Guansong; Mao, Chengde

    2012-12-19

    This communication reports an engineered DNA architecture. It contains multiple domains of half-turn-long, standard B-DNA duplexes. While each helical domain is right-handed and its two component strands are antiparallel, the global architecture is left-handed and the two component DNA strands are oriented parallel to each other.

  13. Review of the helicity formalism; Revision del formalismo de helicidad

    Energy Technology Data Exchange (ETDEWEB)

    Barreiro, F.; Cerrada, M.; Fernandez, E.

    1972-07-01

    Our purpose in these notes has been to present a brief and general review of the helicity formalism. We begin by discussing Lorentz invariance, spin and helicity ideas, in section 1 . In section 2 we deal with the construction of relativistic states and scattering amplitudes in the helicity basis and we study their transformation properties under discrete symmetries. Finally we present some more sophisticated topics like kinematical singularities of helicity amplitudes, kinematical constraints and crossing relations 3, 4, 5 respectively. (Author) 8 refs.

  14. Structure and Protein-Protein Interaction Studies on Chlamydia trachomatis Protein CT670 (YscO Homolog)

    Energy Technology Data Exchange (ETDEWEB)

    Lorenzini, Emily; Singer, Alexander; Singh, Bhag; Lam, Robert; Skarina, Tatiana; Chirgadze, Nickolay Y.; Savchenko, Alexei; Gupta, Radhey S. (Toronto); (McMaster U.); (OCI)

    2010-07-28

    Comparative genomic studies have identified many proteins that are found only in various Chlamydiae species and exhibit no significant sequence similarity to any protein in organisms that do not belong to this group. The CT670 protein of Chlamydia trachomatis is one of the proteins whose genes are in one of the type III secretion gene clusters but whose cellular functions are not known. CT670 shares several characteristics with the YscO protein of Yersinia pestis, including the neighboring genes, size, charge, and secondary structure, but the structures and/or functions of these proteins remain to be determined. Although a BLAST search with CT670 did not identify YscO as a related protein, our analysis indicated that these two proteins exhibit significant sequence similarity. In this paper, we report that the CT670 crystal, solved at a resolution of 2 {angstrom}, consists of a single coiled coil containing just two long helices. Gel filtration and analytical ultracentrifugation studies showed that in solution CT670 exists in both monomeric and dimeric forms and that the monomer predominates at lower protein concentrations. We examined the interaction of CT670 with many type III secretion system-related proteins (viz., CT091, CT665, CT666, CT667, CT668, CT669, CT671, CT672, and CT673) by performing bacterial two-hybrid assays. In these experiments, CT670 was found to interact only with the CT671 protein (YscP homolog), whose gene is immediately downstream of ct670. A specific interaction between CT670 and CT671 was also observed when affinity chromatography pull-down experiments were performed. These results suggest that CT670 and CT671 are putative homologs of the YcoO and YscP proteins, respectively, and that they likely form a chaperone-effector pair.

  15. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  16. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Wu, T-H [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec.1, Jianguo N.Rd, Taichung City 40201, Taiwan (China); Liang, C-H [Agfa Healthcare Systems Taiwan Co., Ltd., 6F, 237 Sung Chiang Road, Taipei, 104 Taiwan (China); Wu, J-K [Division of Radiation Oncology, Department of Oncology, and Cancer Research Center, National Taiwan University Hospital, No.7 Chung San South Road, Taipei, 104 Taiwan (China); Lien, C-Y [Institute of Biomedical Engineering, National Yang Ming University, No. 155, Sec.2, Linong Street, Taipei, 112 Taiwan (China); Yang, B-H; Lee, J J S [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, No. 155, Sec.2, Linong Street, Taipei, 112 Taiwan (China); Huang, Y-H [Department of Medical Imaing and Radiological Sciences, I-Shou University, No. 8, Yida Rd., Yanchao Township, Kaohsiung County 82445, Taiwan (China)], E-mail: jslee@ym.edu.tw

    2009-07-15

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT

  17. Three dimensional CT of stapes. Stapedial imagings in dry temporal bone and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Kubota, Osamu; Yamashita, Koichi [Kanazawa Medical Univ., Ishikawa (Japan)

    1995-03-01

    This study was performed to evaluate the usefulness and limitations of three dimensional (3-D) imagings of stapes in the middle ear by high speed helical CT. One dissected human temporal bone, ten normal and diseased ears were scanned with a slice of 1.0 mm and reconstructed in a thickness of 0.2-0.5 mm. Every specimen of 3-D can be observed in any plane and from any direction. Ossicular imagings of the temporal bone in 3-D were reconstructed as if the malleus, incus and stapes were observed under microscope. The whole structure of stapes was impossible to be represented by two dimensional CT heretofore in use, but 3-D in our study showed the head, crus and foot plate of the stapes in detail. Stapedial imagings of 3-D CT in normal ears showed the same findings as those recorded in temporal bone. Preoperative diagnostic findings of ossicles in the affected ears were very useful. Especially in ossicular anomalies, 3-D CT was positive in diagnosis and its accuracies were confirmed with operative observation. For the postoperative evaluation concerning the ossicular reconstruction, i.e. TORP and PORP, 3-D CT was also important method. It could present an anatomical relation between those prosthesis and the oval window. High speed helical CT can scan an object more quickly and clearly than formerly used CT, and its biological damage for human is less than that of the others. 3-D CT can be more clearly reconstructed with helical CT than former CT. (author).

  18. Helicity of Solar Active Regions from a Dynamo Model

    Indian Academy of Sciences (India)

    Piyali Chatterjee

    2006-06-01

    We calculate helicities of solar active regions based on the idea that poloidal flux lines get wrapped around a toroidal flux tube rising through the convection zone, thereby giving rise to the helicity. We use our solar dynamo model based on the Babcock–Leighton -effect to study how helicity varies with latitude and time.

  19. Sign of helicity in the alpha-Omega geodynamo

    CERN Document Server

    Wei, Xing

    2010-01-01

    In this paper we investigate the sign of helicity in the alpha-Omega dynamo and point out that the alpha effect in the geodynamo is induced by helical wave but not helical flow as in the solar dynamo. We then postulate the mechanisms of the Earth's magnetic tilt angle, westward drift and dipole reversals.

  20. Field-theoretic calculation of kinetic helicity flux

    Indian Academy of Sciences (India)

    V Avinash; Mahendra K Verma; Amar K Chandra

    2006-02-01

    In this paper we apply perturbative field-theoretic technique to helical turbulence. In the inertial range the kinetic helicity flux is found to be constant and forward. The universal constant H appearing in the spectrum of kinetic helicity was found to be 2.47.

  1. The Effects of Spatial Smoothing on Solar Magnetic Helicity and the Hemispheric Helicity Sign Rule

    Science.gov (United States)

    Koch Ocker, Stella; Petrie, Gordon

    2016-05-01

    The hemispheric sign rule for solar magnetic helicity, which states that negative/positive helicity occurs preferentially in the northern/southern hemisphere, provides clues to the causes of twisted, flaring magnetic fields. However, previous studies on the hemisphere rule may have been significantly affected by seeing from atmospheric turbulent motions. Using Hinode/SOT-SP data spanning from 2006 to 2012, we studied the effects of two important data processing steps that imitate the effects of atmospheric seeing: noise reduction by ignoring pixel values that are weaker than the estimated noise threshold, and Gaussian spatial smoothing. We applied these processing techniques to the helicity distribution maps for active regions NOAA 11158 and NOAA 11243, along with the average helicities of 36 active regions, in order to imitate and understand the effects of seeing from atmospheric turbulence. We found that rather than changing trends in the helicity distributions, Gaussian smoothing and noise reduction enhanced existing trends by pushing outliers towards the mean or removing them altogether. We also found that, when separated for weak and strong magnetic fields, the average helicities of the 36 active regions conformed to the hemisphere rule for weak field helicities and breached the rule for strong field helicities. In general, we found that data processing did not affect whether the hemisphere rule held for data taken from space-based instruments, and thus that seeing from atmospheric turbulence did not significantly affect previous studies' ground-based results on the hemisphere rule. This work was carried out through the National Solar Observatory Research Experiences for Undergraduates (REU) Program, which is funded by the National Science Foundation (NSF). The National Solar Observatory is operated by the Association of Universities for Research in Astronomy, Inc. (AURA) under cooperative agreement with the NSF.

  2. The value of PET, CT and in-line PET/CT in patients with gastrointestinal stromal tumours: long-term outcome of treatment with imatinib mesylate

    Energy Technology Data Exchange (ETDEWEB)

    Goerres, G.W.; Hany, T.F.; Schulthess, G.K. von [University Hospital Zurich, Division of Nuclear Medicine, Zurich (Switzerland); Stupp, R.; Luthi, F.; Leyvraz, S. [University of Lausanne Medical Centre, Multidisciplinary Oncology Centre, Lausanne (Switzerland); Barghouth, G.; Schnyder, P. [University of Lausanne Medical Centre, Department of Radiology, Lausanne (Switzerland); Pestalozzi, B. [University Hospital Zurich, Department of Oncology, Zurich (Switzerland); Dizendorf, E. [University Hospital Zurich, Division of Nuclear Medicine, Zurich (Switzerland); International Tomography Center, Novosibirsk (Russian Federation)

    2005-02-01

    Gastrointestinal stromal tumours (GIST) are mesenchymal neoplasms of the gastrointestinal tract that are unresponsive to standard sarcoma chemotherapy. Imaging of GIST patients is done with structural and functional methods such as contrast-enhanced helical computed tomography (ceCT) and positron emission tomography (PET) with {sup 18}F-fluorodeoxyglucose (FDG). The aim of this study was to compare the prognostic power of PET and ceCT and to evaluate the clinical role of PET/CT imaging. All patients with GIST undergoing PET or PET/CT examinations were prospectively included in this study, and the median overall survival, time to progression and treatment duration were documented. The prognostic significance of PET and ceCT criteria of treatment response was assessed and PET/CT was compared with PET and ceCT imaging. Data for 34 patients (19 male, 15 female, 21-76 years) undergoing PET or PET/CT for staging or restaging were analysed. In 28 patients, PET/CT and ceCT were available after introduction of treatment with the tyrosine kinase inhibitor imatinib mesylate (Gleevec; Novartis, Basel, Switzerland). Patients without FDG uptake after the start of treatment had a better prognosis than patients with residual activity. In contrast, ceCT criteria provided insufficient prognostic power. However, more lesions were found on ceCT images than on PET images, and FDG uptake was sometimes very variable. PET/CT delineated active lesions better than did the combination of PET and ceCT imaging. Both PET and PET/CT provide important prognostic information and have an impact on clinical decision-making in GIST patients. PET/CT precisely delineates lesions and thus allows for the correct planning of surgical interventions. (orig.)

  3. Strategies to reduce radiation dose in cardiac PET/CT

    Science.gov (United States)

    Wu, Tung Hsin; Wu, Nien-Yun; Wang, Shyh-Jen; Wu, Jay; S. P. Mok, Greta; Yang, Ching-Ching; Huang, Tzung-Chi

    2011-08-01

    Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications.MaterialsImage quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan.ResultsRadiation dose in RGH technique was 22.2±4.0 mSv. It was reduced to 10.95±0.82 and 4.13±0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53±0.5 to 0.16±0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols.ConclusionThe proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  4. Computer-aided diagnosis workstation and network system for chest diagnosis based on multislice CT images

    Science.gov (United States)

    Satoh, Hitoshi; Niki, Noboru; Eguchi, Kenji; Moriyama, Noriyuki; Ohmatsu, Hironobu; Masuda, Hideo; Machida, Suguru

    2008-03-01

    Mass screening based on multi-helical CT images requires a considerable number of images to be read. It is this time-consuming step that makes the use of helical CT for mass screening impractical at present. To overcome this problem, we have provided diagnostic assistance methods to medical screening specialists by developing a lung cancer screening algorithm that automatically detects suspected lung cancers in helical CT images, a coronary artery calcification screening algorithm that automatically detects suspected coronary artery calcification and a vertebra body analysis algorithm for quantitative evaluation of osteoporosis likelihood by using helical CT scanner for the lung cancer mass screening. The function to observe suspicious shadow in detail are provided in computer-aided diagnosis workstation with these screening algorithms. We also have developed the telemedicine network by using Web medical image conference system with the security improvement of images transmission, Biometric fingerprint authentication system and Biometric face authentication system. Biometric face authentication used on site of telemedicine makes "Encryption of file" and Success in login" effective. As a result, patients' private information is protected. Based on these diagnostic assistance methods, we have developed a new computer-aided workstation and a new telemedicine network that can display suspected lesions three-dimensionally in a short time. The results of this study indicate that our radiological information system without film by using computer-aided diagnosis workstation and our telemedicine network system can increase diagnostic speed, diagnostic accuracy and security improvement of medical information.

  5. Malignant focal hepatic lesions complicating underlying liver disease: dual-phase contrast-enhanced spiral CT sensitivity and specificity in orthotopic liver transplant patients

    Energy Technology Data Exchange (ETDEWEB)

    Mortele, K.J. [Dept. of Radiology, University Hospital Gent (Belgium); Department of Radiology, Brigham and Women' s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 (United States); De Keukeleire, K. [Dept. of Radiology, University Hospital Gent (Belgium); Praet, M. [Dept. of Pathology, University Hospital Gent, Gent (Belgium); Van Vlierberghe, H. [Dept. of Gastroenterology, University Hospital Gent, Gent (Belgium); Hemptinne, B. de [Dept. of Surgery, University Hospital Gent, Gent (Belgium); Ros, P.R. [Department of Radiology, Brigham and Women' s Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115 (United States)

    2001-09-01

    The aim of this study was to determine the accuracy of contrast-enhanced biphasic spiral CT as a screening tool in the preoperative evaluation of orthotopic liver transplant (OLT) patients. Spiral-CT examinations were performed before liver transplantation in 53 patients. Scans were retrospectively reviewed and compared with pathologic findings in fresh-sectioned livers. When findings between spiral CT and pathology were discordant, formalized livers were reexamined with lesion-by lesion evaluation. Fresh pathologic evaluation revealed 23 liver lesions (16 HCC, 7 macro-regenerative nodules). Malignancy was identified in 13 of 53 patients (24.5%). Pre-transplantation spiral CT depicted 27 liver lesions (23 HCC, 4 macro-regenerative nodules). Malignancy was suspected in 14 patients (26.4%). In 10 of 53 (18.9%), spiral CT and pathologic evaluation were discordant. Subsequent retrospective pathologic evaluation showed malignancy in 4 additional patients. Spiral CT compared with the retrospective pathologic findings revealed 36 real-negative, 14 real-positive, 0 false-positive, and 3 false-negative patients with malignancy. Sensitivity and specificity of spiral CT in detection of malignancy was 82 and 100%, respectively. Contrast-enhanced biphasic spiral CT is an accurate technique in the evaluation of patients preceding OLT. Routine fresh-sectioned liver pathologic findings are not as sensitive as previously estimated. (orig.)

  6. What Helicity Can Tell Us about Solar Magnetic Fields

    Indian Academy of Sciences (India)

    Alexei A. Pevtsov

    2008-03-01

    Concept of magnetic/current helicity was introduced to solar physics about 15 years ago. Earlier studies led to discovery of such fundamental properties as hemispheric helicity rule, and role of helicity in magnetic reconnection and solar eruptions. Later, the concept was successfully applied in studies of different solar processes from solar dynamo to flare and CME phenomena. Although no silver bullet, helicity has proven to be a very useful “tool” in answering many still-puzzling questions about origin and evolution of solar magnetic fields. I present an overview of some helicity studies and briefly analyze their findings.

  7. Time-Mean Helicity Distribution in Turbulent Swirling Jets

    Directory of Open Access Journals (Sweden)

    V. Tesař

    2005-01-01

    Full Text Available Helicity offers an alternative approach to investigations of the structure of turbulent flows. Knowledge of the spatial distribution of the time-mean component of helicity is the starting point. Yet very little is known even about basic cases in which Helicity plays important role, such as the case of a swirling jet. This is the subject of the present investigations, based mainly on numerical flowfield computations. The region of significantly large time-mean helicity density is found only in a rather small region reaching to several nozzle diameters downstream from the exit. The most important result is the similarity of the helicity density profiles. 

  8. Ion temperature gradient modes in toroidal helical systems

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, T. [Graduate University for Advanced Studies, Toki, Gifu (Japan); Sugama, H.; Kanno, R.; Okamoto, M.

    2000-04-01

    Linear properties of ion temperature gradient (ITG) modes in helical systems are studied. The real frequency, growth rate, and eigenfunction are obtained for both stable and unstable cases by solving a kinetic integral equation with proper analytic continuation performed in the complex frequency plane. Based on the model magnetic configuration for toroidal helical systems like the Large Helical Device (LHD), dependences of the ITG mode properties on various plasma equilibrium parameters are investigated. Particularly, relative effects of {nabla}B-curvature drifts driven by the toroidicity and by the helical ripples are examined in order to compare the ITG modes in helical systems with those in tokamaks. (author)

  9. Biphasic Catalytic(Hydroformylation of 1-Dodecene in Micellar System with Cationic Gemini Surfactants

    Institute of Scientific and Technical Information of China (English)

    Min LI; Bin XU; Hua CHEN; Hong Jie ZHENG; Xue Yuan HUANG; Yao Zhong LI; Xian Jun LI

    2004-01-01

    The promotion effect of cationic gemini surfactants for the hydroformylation of 1-dodecene in the organic/aqueous biphasic catalytic system is reported. The hydroformylation reaction in the presence of gemini surfactant occurred with higher turnover frequency and higher selectivity for linear aldehyde than using conventional monomeric surfactant CTAB.

  10. Modeling Biphasic Environmental Decay of Pathogens and Implications for Risk Analysis.

    Science.gov (United States)

    Brouwer, Andrew F; Eisenberg, Marisa C; Remais, Justin V; Collender, Philip A; Meza, Rafael; Eisenberg, Joseph N S

    2017-02-21

    As the appreciation for the importance of the environment in infectious disease transmission has grown, so too has interest in pathogen fate and transport. Fate has been traditionally described by simple exponential decay, but there is increasing recognition that some pathogens demonstrate a biphasic pattern of decay-fast followed by slow. While many have attributed this behavior to population heterogeneity, we demonstrate that biphasic dynamics can arise through a number of plausible mechanisms. We examine the identifiability of a general model encompassing three such mechanisms: population heterogeneity, hardening off, and the existence of viable-but-not-culturable states. Although the models are not fully identifiable from longitudinal sampling studies of pathogen concentrations, we use a differential algebra approach to determine identifiable parameter combinations. Through case studies using Cryptosporidium and Escherichia coli, we show that failure to consider biphasic pathogen dynamics can lead to substantial under- or overestimation of disease risks and pathogen concentrations, depending on the context. More reliable models for environmental hazards and human health risks are possible with an improved understanding of the conditions in which biphasic die-off is expected. Understanding the mechanisms of pathogen decay will ultimately enhance our control efforts to mitigate exposure to environmental contamination.

  11. A New Type of Biphasic Calcium Phosphate Cement as a Gentamicin Carrier for Osteomyelitis

    Directory of Open Access Journals (Sweden)

    Wen-Yu Su

    2013-01-01

    Full Text Available Osteomyelitis therapy is a long-term and inconvenient procedure for a patient. Antibiotic-loaded bone cements are both a complementary and alternative treatment option to intravenous antibiotic therapy for the treatment of osteomyelitis. In the current study, the biphasic calcium phosphate cement (CPC, called α-TCP/HAP (α-tricalcium phosphate/hydroxyapatite biphasic cement, was prepared as an antibiotics carrier for osteomyelitis. The developed biphasic cement with a microstructure of α-TCP surrounding the HAP has a fast setting time which will fulfill the clinical demand. The X-ray diffraction and Fourier transform infrared spectrometry analyses showed the final phase to be HAP, the basic bone mineral, after setting for a period of time. Scanning electron microscopy revealed a porous structure with particle sizes of a few micrometers. The addition of gentamicin in α-TCP/HAP would delay the transition of α-TCP but would not change the final-phase HAP. The gentamicin-loaded α-TCP/HAP supplies high doses of the antibiotic during the initial 24 hours when they are soaked in phosphate buffer solution (PBS. Thereafter, a slower drug release is produced, supplying minimum inhibitory concentration until the end of the experiment (30 days. Studies of growth inhibition of Staphylococcus aureus and Pseudomonas aeruginosa in culture indicated that gentamicin released after 30 days from α-TCP/HAP biphasic cement retained antibacterial activity.

  12. Biphasic Electrical Field Stimulation Aids in Tissue Engineering of Multicell-Type Cardiac Organoids

    Science.gov (United States)

    Chiu, Loraine L.Y.; Iyer, Rohin K.; King, John-Paul

    2011-01-01

    The main objectives of current work were (1) to compare the effects of monophasic or biphasic electrical field stimulation on structure and function of engineered cardiac organoids based on enriched cardiomyocytes (CM) and (2) to determine if electrical field stimulation will enhance electrical excitability of cardiac organoids based on multiple cell types. Organoids resembling cardiac myofibers were cultivated in Matrigel-coated microchannels fabricated of poly(ethylene glycol)-diacrylate. We found that field stimulation using symmetric biphasic square pulses at 2.5 V/cm, 1 Hz, 1 ms (per pulse phase) was an improved stimulation protocol, as compared to no stimulation and stimulation using monophasic square pulses of identical total amplitude and duration (5 V/cm, 1 Hz, 2 ms). This was supported by the highest success rate for synchronous contractions, low excitation threshold, the highest cell density, and the highest expression of Connexin-43 in the biphasic group. Subsequently, enriched CM were seeded on the networks of (1) cardiac fibroblasts (FB), (2) D4T endothelial cells (EC), or (3) a mixture of FB and EC that were precultured for 2 days prior to the addition of enriched CM. Biphasic field stimulation was also effective at improving electrical excitability of these cardiac organoids by improving the three-dimensional organization of the cells, increasing cellular elongation and enhancing Connexin-43 presence. PMID:18783322

  13. Biphasic electrical field stimulation aids in tissue engineering of multicell-type cardiac organoids.

    Science.gov (United States)

    Chiu, Loraine L Y; Iyer, Rohin K; King, John-Paul; Radisic, Milica

    2011-06-01

    The main objectives of current work were (1) to compare the effects of monophasic or biphasic electrical field stimulation on structure and function of engineered cardiac organoids based on enriched cardiomyocytes (CM) and (2) to determine if electrical field stimulation will enhance electrical excitability of cardiac organoids based on multiple cell types. Organoids resembling cardiac myofibers were cultivated in Matrigel-coated microchannels fabricated of poly(ethylene glycol)-diacrylate. We found that field stimulation using symmetric biphasic square pulses at 2.5 V/cm, 1 Hz, 1 ms (per pulse phase) was an improved stimulation protocol, as compared to no stimulation and stimulation using monophasic square pulses of identical total amplitude and duration (5 V/cm, 1 Hz, 2 ms). This was supported by the highest success rate for synchronous contractions, low excitation threshold, the highest cell density, and the highest expression of Connexin-43 in the biphasic group. Subsequently, enriched CM were seeded on the networks of (1) cardiac fibroblasts (FB), (2) D4T endothelial cells (EC), or (3) a mixture of FB and EC that were precultured for 2 days prior to the addition of enriched CM. Biphasic field stimulation was also effective at improving electrical excitability of these cardiac organoids by improving the three-dimensional organization of the cells, increasing cellular elongation and enhancing Connexin-43 presence.

  14. Calculation of the valence electron structures of alloying cementite and its biphase interface

    Institute of Scientific and Technical Information of China (English)

    刘志林; 李志林; 刘伟东

    2001-01-01

    The valence electron structures of alloying cementite θ-(Fe, M)3C and ε-(Fe, M)3C andthose of the biphase interfaces between them and α-Fe are calculated with Yu's empirical electrontheory of solid and molecules. The calculation results accord with the actual behavior of alloys.

  15. Intracellular lactate-mediated induction of estrogen receptor beta (ERβ) in biphasic malignant pleural mesothelioma cells.

    Science.gov (United States)

    Manente, Arcangela G; Pinton, Giulia; Zonca, Sara; Cilli, Michele; Rinaldi, Maurizio; Daga, Antonio; Nilsson, Stefan; Moro, Laura

    2015-09-22

    Biphasic malignant pleural mesothelioma (MPM) is the second most common histotype of MPM. It is histologically characterized by the concomitant presence of epithelioid and sarcomatoid features, the latter associated with worse prognosis. In this report we describe that silencing of AKT1 in spindle-shaped biphasic MPM cells promotes the shift toward an epithelioid phenotype. Furthermore, AKT1 silencing resulted in decreased expression of the lactate/H+ symporter MCT4 and its chaperone CD147/Basigin, and in the induction of estrogen receptor β (ERβ) expression. We provide evidence that ERβ expression is induced by increased intracellular lactate concentration. Spheroid culturing and tumor growth of ERβ negative biphasic MPM in nude mice resulted in the induction of ERβ expression and response to the selective agonist KB9520. In both models, the treatment with the ERβ agonist results in reduced cell proliferation, decreased expression of MCT4 and CD147/Basigin and increased acetylation and inactivation of AKT1. Collectively, in response to metabolic changes, ERβ expression is induced and exerts an anti-tumor effect through selective agonist activation. The possibility to reverse the more aggressive biphasic mesothelioma histotype by targeting ERβ with a selective agonist could represent a new effective treatment strategy.

  16. Phase Behaviors in Bi-phase Simulation of Powder Segregation in Metal Injection Molding

    Institute of Scientific and Technical Information of China (English)

    Liu Baosheng; Fan Xiaoxin; Cheng Zhiqiang

    2006-01-01

    Powder segregation induced by mold filling is an important phenomenon that affects the final quality of metal injection molding (MIM). The prediction of segregation in MIM requires a bi-phase flow model to describe distinctly the flows of metallic powder and polymer binder. Viscous behaviors for the flows of each phase should hence be determined. The coefficient of interaction between the flows of two phases should also be evaluated. However, only viscosity of the mixed feedstock is measurable by capillary tests. Wall sticking is supposed in the traditional model for capillary tests, while the wall slip is important to be taken into account in MIM injection. Objective of the present paper is to introduce the slip effect in bi-phase simulation, and search the suitable way to determine the viscous behaviors for each phase with the consideration of wall slip in capillary tests. Analytical and numerical methods were proposed to realize such a specific purpose. The proposed method is based on the mass conservation between the capillary flows in mono-phase model for the mixed feedstock and in bi-phase model for the flows of two phases. Examples of the bi-phase simulation in MIM were realized with the software developed by research team. The results show evident segregation, which is valuable for improving the mould designs.

  17. Engineering anisotropic biphasic Janus-type polymer nanofiber scaffold networks via centrifugal jet spinning.

    Science.gov (United States)

    Khang, Alex; Ravishankar, Prashanth; Krishnaswamy, Aditya; Anderson, Patrick K; Cone, Stephanie G; Liu, Zizhao; Qian, Xianghong; Balachandran, Kartik

    2017-11-01

    Biphasic materials, comprised of an ordered arrangement of two different material phases within a material, have the potential for a wide variety of applications including filtration, protective clothing and tissue engineering. This study reports for the first time, a process for engineering biphasic Janus-type polymeric nanofiber (BJPNF) networks via the centrifugal jet spinning technique. BJPNF alignment and fiber diameter was dependent on fabrication rotational speed as well as solution composition. The biphasic character of these BJPNFs, which was controlled via the rotational speed of fabrication, was confirmed at the individual nanofiber scale using energy dispersive X-ray spectroscopy, and at the bulk, macro-scale using attenuated total reflectance-Fourier transform infrared spectroscopy. Biphasic character was also demonstrated at the functional level via differing affinities on either side of the BJPNF for cell attachment. Our work thus presents a method for fabricating BJPNF scaffold networks where there might be a need for different properties on either side of a material. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2455-2464, 2017. © 2016 Wiley Periodicals, Inc.

  18. Paired associative stimulation targeting the tibialis anterior muscle using either mono or biphasic transcranial magnetic stimulation

    DEFF Research Database (Denmark)

    Mrachacz-Kersting, Natalie; Stevenson, Andrew James Thomas

    2017-01-01

    Paired associative stimulation (PAS) protocols induce plastic changes within the motor cortex. The objectives of this study were to investigate PAS effects targeting the tibialis anterior (TA) muscle using a biphasic transcranial magnetic stimulation (TMS) pulse form and, to determine whether...

  19. CHRONIC ALCOHOL CONSUMPTION HAS BIPHASIC EFFECTS ON HEPATIC INSULIN SIGNALING DEPENDENT ON DOSE

    Science.gov (United States)

    Epidemiological studies have shown paradoxical biphasic effects of alcohol on health. Moderate drinkers have lower overall mortality than teetotalers or than heavy drinkers. There are protective effects of low levels of alcohol consumption (less than one drink day) on diabetes risk and other chroni...

  20. Magnetic helicity balance in the Sustained Spheromak Plasma Experiment

    Science.gov (United States)

    Stallard, B. W.; Hooper, E. B.; Woodruff, S.; Bulmer, R. H.; Hill, D. N.; McLean, H. S.; Wood, R. D.

    2003-07-01

    The magnetic helicity balance between the helicity input injected by a magnetized coaxial gun, the rate-of-change in plasma helicity content, and helicity dissipation in electrode sheaths and Ohmic losses have been examined in the Sustained Spheromak Plasma Experiment (SSPX) [E. B. Hooper, L. D. Pearlstein, and R. H. Bulmer, Nucl. Fusion 39, 863 (1999)]. Helicity is treated as a flux function in the mean-field approximation, allowing separation of helicity drive and losses between closed and open field volumes. For nearly sustained spheromak plasmas with low fluctuations, helicity balance analysis implies a decreasing transport of helicity from the gun input into the spheromak core at higher spheromak electron temperature. Long pulse discharges with continuously increasing helicity and larger fluctuations show higher helicity coupling from the edge to the spheromak core. The magnitude of the sheath voltage drop, inferred from cathode heating and a current threshold dependence of the gun voltage, shows that sheath losses are important and reduce the helicity injection efficiency in SSPX.

  1. Large-scale flow generation by inhomogeneous helicity

    CERN Document Server

    Yokoi, Nobumitsu

    2015-01-01

    The effect of kinetic helicity (velocity--vorticity correlation) on turbulent momentum transport is investigated. The turbulent kinetic helicity (pseudoscalar) enters into the Reynolds stress (mirrorsymmetric tensor) expression in the form of a helicity gradient as the coupling coefficient for the mean vorticity and/or the angular velocity (axial vector), which suggests the possibility of mean-flow generation in the presence of inhomogeneous helicity. This inhomogeneous helicity effect, which was previously confirmed at the level of a turbulence- or closure-model simulation, is examined with the aid of direct numerical simulations of rotating turbulence with non-uniform helicity sustained by an external forcing. The numerical simulations show that the spatial distribution of the Reynolds stress is in agreement with the helicity-related term coupled with the angular velocity, and that a large-scale flow is generated in the direction of angular velocity. Such a large-scale flow is not induced in the case of hom...

  2. Autonomously folded α-helical lockers promote RNAi*

    Science.gov (United States)

    Guyader, Christian P. E.; Lamarre, Baptiste; De Santis, Emiliana; Noble, James E.; Slater, Nigel K.; Ryadnov, Maxim G.

    2016-01-01

    RNAi is an indispensable research tool with a substantial therapeutic potential. However, the complete transition of the approach to an applied capability remains hampered due to poorly understood relationships between siRNA delivery and gene suppression. Here we propose that interfacial tertiary contacts between α-helices can regulate siRNA cytoplasmic delivery and RNAi. We introduce a rationale of helical amphipathic lockers that differentiates autonomously folded helices, which promote gene silencing, from helices folded with siRNA, which do not. Each of the helical designs can deliver siRNA into cells via energy-dependent endocytosis, while only autonomously folded helices with pre-locked hydrophobic interfaces were able to promote statistically appreciable gene silencing. We propose that it is the amphipathic locking of interfacing helices prior to binding to siRNA that enables RNAi. The rationale offers structurally balanced amphipathic scaffolds to advance the exploitation of functional RNAi. PMID:27721465

  3. Autonomously folded α-helical lockers promote RNAi.

    Science.gov (United States)

    Guyader, Christian P E; Lamarre, Baptiste; De Santis, Emiliana; Noble, James E; Slater, Nigel K; Ryadnov, Maxim G

    2016-10-10

    RNAi is an indispensable research tool with a substantial therapeutic potential. However, the complete transition of the approach to an applied capability remains hampered due to poorly understood relationships between siRNA delivery and gene suppression. Here we propose that interfacial tertiary contacts between α-helices can regulate siRNA cytoplasmic delivery and RNAi. We introduce a rationale of helical amphipathic lockers that differentiates autonomously folded helices, which promote gene silencing, from helices folded with siRNA, which do not. Each of the helical designs can deliver siRNA into cells via energy-dependent endocytosis, while only autonomously folded helices with pre-locked hydrophobic interfaces were able to promote statistically appreciable gene silencing. We propose that it is the amphipathic locking of interfacing helices prior to binding to siRNA that enables RNAi. The rationale offers structurally balanced amphipathic scaffolds to advance the exploitation of functional RNAi.

  4. Autonomously folded α-helical lockers promote RNAi*

    Science.gov (United States)

    Guyader, Christian P. E.; Lamarre, Baptiste; de Santis, Emiliana; Noble, James E.; Slater, Nigel K.; Ryadnov, Maxim G.

    2016-10-01

    RNAi is an indispensable research tool with a substantial therapeutic potential. However, the complete transition of the approach to an applied capability remains hampered due to poorly understood relationships between siRNA delivery and gene suppression. Here we propose that interfacial tertiary contacts between α-helices can regulate siRNA cytoplasmic delivery and RNAi. We introduce a rationale of helical amphipathic lockers that differentiates autonomously folded helices, which promote gene silencing, from helices folded with siRNA, which do not. Each of the helical designs can deliver siRNA into cells via energy-dependent endocytosis, while only autonomously folded helices with pre-locked hydrophobic interfaces were able to promote statistically appreciable gene silencing. We propose that it is the amphipathic locking of interfacing helices prior to binding to siRNA that enables RNAi. The rationale offers structurally balanced amphipathic scaffolds to advance the exploitation of functional RNAi.

  5. Helicity, Topology and Kelvin Waves in reconnecting quantum knots

    CERN Document Server

    di Leoni, P Clark; Brachet, M E

    2016-01-01

    Helicity is a topological invariant that measures the linkage and knottedness of lines, tubes and ribbons. As such, it has found myriads of applications in astrophysics and solar physics, in fluid dynamics, in atmospheric sciences, and in biology. In quantum flows, where topology-changing reconnection events are a staple, helicity appears as a key quantity to study. However, the usual definition of helicity is not well posed in quantum vortices, and its computation based on counting links and crossings of vortex lines can be downright impossible to apply in complex and turbulent scenarios. We present a new definition of helicity which overcomes these problems. With it, we show that only certain reconnection events conserve helicity. In other cases helicity can change abruptly during reconnection. Furthermore, we show that these events can also excite Kelvin waves, which slowly deplete helicity as they interact nonlinearly, thus linking the theory of vortex knots with observations of quantum turbulence.

  6. Evolution of field line helicity during magnetic reconnection

    CERN Document Server

    Russell, Alexander J B; Hornig, Gunnar; Wilmot-Smith, Antonia L

    2015-01-01

    We investigate the evolution of field line helicity for non-zero magnetic fields that connect two boundaries, with emphasis on localized finite-B magnetic reconnection. Total (relative) magnetic helicity is already recognized as an important topological constraint on magnetohydrodynamic processes. Field line helicity offers further advantages because it preserves all topological information and can distinguish between different magnetic fields with the same total helicity. Magnetic reconnection changes field topology and field line helicity reflects these changes; the goal of this paper is to characterize that evolution. We start by deriving the evolution equation for field line helicity and examining its terms, also obtaining a simplified form for cases where dynamics are localized within the domain. The main result, which we support using kinematic examples, is that during localized reconnection in a topologically complex magnetic field, the evolution of field line helicity is dominated by a work-like term ...

  7. Stabilization of helical macromolecular phases by confined bending

    CERN Document Server

    Williams, Matthew J

    2015-01-01

    By means of extensive replica-exchange simulations of generic coarse-grained models for helical polymers, we systematically investigate the structural transitions into all possible helical phases for flexible and semiflexible elastic polymers with self-interaction under the influence of torsion barriers. The competing interactions lead to a variety of conformational phases including disordered helical arrangements, single helices, and ordered, tertiary helix bundles. Most remarkably, we find that a bending restraint entails a clear separation and stabilization of the helical phases. This aids in understanding why semiflexible polymers such as double-stranded DNA tend to form pronounced helical structures and proteins often exhibit an abundance of helical structures, such as helix bundles, within their tertiary structure.

  8. Helicity dynamics in stratified turbulence in the absence of forcing

    CERN Document Server

    Rorai, C; Pouquet, A; Mininni, P D

    2012-01-01

    A numerical study of decaying stably-stratified flows is performed. Relatively high stratification and moderate Reynolds numbers are considered, and a particular emphasis is placed on the role of helicity (velocity-vorticity correlations). The problem is tackled by integrating the Boussinesq equations in a periodic cubical domain using different initial conditions: a non-helical Taylor-Green (TG) flow, a fully helical Beltrami (ABC) flow, and random flows with a tunable helicity. We show that for stratified ABC flows helicity undergoes a substantially slower decay than for unstratified ABC flows. This fact is likely associated to the combined effect of stratification and large scale coherent structures. Indeed, when the latter are missing, as in random flows, helicity is rapidly destroyed by the onset of gravitational waves. A type of large-scale dissipative "cyclostrophic" balance can be invoked to explain this behavior. When helicity survives in the system it strongly affects the temporal energy decay and t...

  9. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the scanner at one time such as with MRI. If an intravenous contrast material is used, you ... CT is less sensitive to patient movement than MRI. CT can be performed if you have an ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ...

  14. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... lives. CT has been shown to be a cost-effective imaging tool for a wide range of ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, ... the body being studied. top of page How is the procedure performed? The technologist begins by positioning ...

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. In emergency cases, it ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  2. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  3. CT Grading of Otosclerosis

    National Research Council Canada - National Science Library

    Lee, T.C; Aviv, R.I; Chen, J.M; Nedzelski, J.M; Fox, A.J; Symons, S.P

    2009-01-01

    ...: The CT grading system for otosclerosis was proposed by Symons and Fanning in 2005. The purpose of this study was to determine if this CT grading system has high interobserver and intraobserver agreement...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging tests and ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanner technique will be adjusted to their size and the area of interest to reduce the ... Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content Some imaging tests and ...

  7. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... page How should I prepare for the CT scan? You should wear comfortable, loose-fitting clothing to ... studied. top of page How is the CT scan performed? The technologist begins by positioning you on ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A CT scan is one of the ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Magnetic Resonance Imaging ( ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Ultrasound - Abdomen X- ...

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning is fast, painless, noninvasive and accurate. In emergency cases, it can reveal internal injuries and ... generated during a CT scan can be reformatted in multiple planes, and can even generate three-dimensional ...

  18. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide ... clicking and whirring sounds as the CT scanner's internal parts, not usually visible to you, revolve around ...

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the cause of unexplained pain. CT scanning is fast, painless, noninvasive and accurate. In emergency cases, it ... additional view capabilities. Modern CT scanners are so fast that they can scan through large sections of ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... which may be causing hearing problems. determine whether inflammation or other changes are present in the paranasal ... CT scans . CT is not sensitive in detecting inflammation of the meninges —the membranes covering the brain. ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a stroke. a stroke, especially with a new technique called Perfusion CT. brain tumors. enlarged brain cavities ( ... brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more information, see the ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... to urinate; however, this is actually a contrast effect and subsides quickly. When you enter the CT ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... to urinate; however, this is actually a contrast effect and subsides quickly. When you enter the CT ...

  4. Cardiac CT Scan

    Science.gov (United States)

    ... combine these pictures to create a three-dimensional (3D) model of the whole heart. This imaging test ... findings from earlier chest x rays. Different CT scanners are used for different purposes. A multidetector CT ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT of the sinuses is primarily used ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  8. Gallstone ileus: CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Delabrousse, E.; Bartholomot, B.; Sohm, O.; Kastler, B. [Dept. of Radiology A, CHU Jean Minjoz, University of Besancon (France); Wallerand, H. [Dept. of Surgery, CHU Jean Minjoz, University of Besancon (France)

    2000-06-01

    Gallstone ileus is a rare complication of recurrent gallstone cholecystitis. The classic radiographic triad of small bowel obstruction, pneumobilia and ectopic gallstone on abdominal plain radiograph is described with CT imaging. Because of the better resolution of CT compared with abdominal radiography and its recent accession to emergency use, radiologists should be aware of CT findings of gallstone ileus. We report a case in which gallstone ileus was initially diagnosed by CT. (orig.)

  9. Iterative assembly of helical proteins by optimal hydrophobic packing.

    Science.gov (United States)

    Wu, G Albert; Coutsias, Evangelos A; Dill, Ken A

    2008-08-06

    We present a method for the computer-based iterative assembly of native-like tertiary structures of helical proteins from alpha-helical fragments. For any pair of helices, our method, called MATCHSTIX, first generates an ensemble of possible relative orientations of the helices with various ways to form hydrophobic contacts between them. Those conformations having steric clashes, or a large radius of gyration of hydrophobic residues, or with helices too far separated to be connected by the intervening linking region, are discarded. Then, we attempt to connect the two helical fragments by using a robotics-based loop-closure algorithm. When loop closure is feasible, the algorithm generates an ensemble of viable interconnecting loops. After energy minimization and clustering, we use a representative set of conformations for further assembly with the remaining helices, adding one helix at a time. To efficiently sample the conformational space, the order of assembly generally proceeds from the pair of helices connected by the shortest loop, followed by joining one of its adjacent helices, always proceeding with the shorter connecting loop. We tested MATCHSTIX on 28 helical proteins each containing up to 5 helices and found it to heavily sample native-like conformations. The average rmsd of the best conformations for the 17 helix-bundle proteins that have 2 or 3 helices is less than 2 A; errors increase somewhat for proteins containing more helices. Native-like states are even more densely sampled when disulfide bonds are known and imposed as restraints. We conclude that, at least for helical proteins, if the secondary structures are known, this rapid rigid-body maximization of hydrophobic interactions can lead to small ensembles of highly native-like structures. It may be useful for protein structure prediction.

  10. Vacuum systems for the ILC helical undulator

    CERN Document Server

    Malyshev, O B; Clarke, J A; Bailey, I R; Dainton, J B; Malysheva, L I; Barber, D P; Cooke, P; Baynham, E; Bradshaw, T; Brummitt, A; Carr, S; Ivanyushenkov, Y; Rochford, J; Moortgat-Pick, G A

    2007-01-01

    The International Linear Collider (ILC) positron source uses a helical undulator to generate polarized photons of ∼10MeV∼10MeV at the first harmonic. Unlike many undulators used in synchrotron radiation sources, the ILC helical undulator vacuum chamber will be bombarded by photons, generated by the undulator, with energies mostly below that of the first harmonic. Achieving the vacuum specification of ∼100nTorr∼100nTorr in a narrow chamber of 4–6mm4–6mm inner diameter, with a long length of 100–200m100–200m, makes the design of the vacuum system challenging. This article describes the vacuum specifications and calculations of the flux and energy of photons irradiating the undulator vacuum chamber and considers possible vacuum system design solutions for two cases: cryogenic and room temperature.

  11. Weaving knotted vector fields with tunable helicity

    CERN Document Server

    Kedia, Hridesh; Dennis, Mark R; Irvine, William T M

    2016-01-01

    We present a general construction of divergence-free knotted vector fields from complex scalar fields, whose closed field lines encode many kinds of knots and links, including torus knots, their cables, the figure-8 knot and its generalizations. As finite-energy physical fields they represent initial states for fields such as the magnetic field in a plasma, or the vorticity field in a fluid. We give a systematic procedure for calculating the vector potential, starting from complex scalar functions with knotted zero filaments, thus enabling an explicit computation of the helicity of these knotted fields. The construction can be used to generate isolated knotted flux tubes, filled by knots encoded in the lines of the vector field. Lastly we give examples of manifestly knotted vector fields with vanishing helicity. Our results provide building blocks for analytical models and simulations alike.

  12. Broadband optical isolator based on helical metamaterials.

    Science.gov (United States)

    Cao, Hu; Yang, ZhenYu; Zhao, Ming; Wu, Lin; Zhang, Peng

    2015-05-01

    Based on helical metamaterials, a new broadband optical isolator with a triple-helix structure is proposed in this paper. The right-handed circularly polarized light can transmit through the isolator with its polarization unchanged. The reverse propagating light, which is caused by the reflection of the latter optical devices, is converted into left-handed circularly polarized light that is suppressed by the proposed isolator because of absorption. Our design has some unprecedented advantages such as broad frequency ranges and a compact structure; moreover, neither polarizers nor adscititious magnetic fields are required. Properties of the isolator are investigated using the finite-difference time-domain method, and this phenomenon is studied by the mechanism of helical antenna theory.

  13. Electronic structure calculations on helical conducting polymers.

    Science.gov (United States)

    Ripoll, Juan D; Serna, Andrei; Guerra, Doris; Restrepo, Albeiro

    2010-10-21

    We present a study of the electronic structure and derived properties of polyfurane (PFu), polypyrrol (PPy), and polythiophene (PTh). Two spatial arrangements are considered: trans chain (tc-PFu, tc-PPy, tc-PTh) and cis α-helical (α-PFu, α-PPy, α-PTh). Even at the small sizes considered here, helical conformations appear to be stable. Band gaps of pure, undoped oligomers fall into the semiconductor range. Density of states (DOS) analysis suggest dense valence and conduction bands. Bond length alternation analysis predicts almost complete delocalization of the π clouds in all spatial arrangements. Doping with electron donors or electron-withdrawing impurities reduces all band gaps close to the metallic regime in addition to increasing the DOS for the valence and conduction bands.

  14. Helicity of the toroidal vortex with swirl

    CERN Document Server

    Bannikova, Elena Yu; Poslavsky, Sergey A

    2016-01-01

    On the basis of solutions of the Bragg-Hawthorne equations we discuss the helicity of thin toroidal vortices with the swirl - the orbital motion along the torus diretrix. It is shown that relationship of the helicity with circulations along the small and large linked circles - directrix and generatrix of the torus - depends on distribution of the azimuthal velocity in the core of the swirling vortex ring. In the case of non-homogeneous swirl this relationship differs from the well-known Moffat relationship - the doubled product of such circulations multiplied by the number of links. The results can be applied to vortices in planetary atmospheres and to vortex movements in the vicinity of active galactic nuclei.

  15. Driving Solar Eruptions via Helicity Condensation

    Science.gov (United States)

    Dahlin, Joel Timothy; Antiochos, Spiro K.; DeVore, C. Richard

    2017-08-01

    One of the important questions in solar physics is, “How does the Sun store and release energy in coronal mass ejections"? Key to answering this question is understanding how the sun (a) stores magnetic energy in the form of a solar filament and (b) suddenly releases this energy as a coronal mass ejection. An important model for the energy release is the ‘magnetic breakout’ - a positive-feedback mechanism between filament ejection and magnetic reconnection. Recent theory and numerical calculations have demonstrated that helicity injected into the corona via photospheric driving can accumulate in the form of a filament channel of strongly sheared magnetic fields that can provide the free energy for a coronal mass ejection. We present preliminary calculations that, for the first time, incorporate helicity injection in a breakout topology to model a fully self-consistent eruption, from filament formation to ejection.

  16. Weyl spinors and the helicity formalism

    CERN Document Server

    Diaz-Cruz, J Lorenzo; Meza-Aldama, O; Perez, Jonathan Reyes

    2015-01-01

    In this work we give a review of the original formulation of the relativistic wave equation for particles with spin one-half. Traditionally \\`a la Dirac, it's proposed that the ``square root'' of the Klein-Gordon (K-G) equation involves a 4 component (Dirac) spinor and in the non-relativistic limit it can be written as 2 equations for two 2 component spinors. On the other hand, there exists Weyl's formalism, in which one works from the beginning with 2 component Weyl spinors, which are the fundamental objects of the helicity formalism. In this work we rederive Weyl's equations directly, starting from K-G equation. We also obtain the electromagnetic interaction through minimal coupling and we get the interaction with the magnetic moment. As an example of the use of that formalism, we calculate Compton scattering using the helicity methods.

  17. Helical apodizers for tunable hyper Gaussian masks

    Science.gov (United States)

    Ojeda-Castañeda, J.; Ledesma, Sergio; Gómez-Sarabia, Cristina M.

    2013-09-01

    We discuss an optical method for controlling the half-width of Gaussian like transmittance windows, by using a pair of absorption masks that have both radial and helical amplitude variations. For describing the radial part of the proposed masks, we employ amplitude transmittance profiles of the form T(ρ) = exp(- ρ s ). For s = 2, one has an amplitude transmittance that is proportional to a Gaussian function. A sub Gaussian mask is defined by a value of s 2, one has super Gaussian masks. Our discussion considers that any of these radially varying masks has also helical modulations. We show that by using a suitable pair of this type of masks, one can control the halfwidth of Gaussian like windows.

  18. Instabilities of a rotating helical rod

    Science.gov (United States)

    Park, Yunyoung; Ko, William; Kim, Yongsam; Lim, Sookkyung

    2016-11-01

    Bacteria such as Escherichia coli and Vibrio alginolyticus have helical flagellar filament. By rotating a motor, which is located at the bottom end of the flagellar filament embedded in the cell body, CCW or CW, they swim forward or backward. We model a left-handed helix by the Kirchhoff rod theory and use regularized Stokes formulation to study an interaction between the surrounding fluid and the flagellar filament. We perform numerical studies focusing on relations between physical parameters and critical angular frequency of the motor, which separates overwhiring from twirling. We are also interested in the buckling instability of the hook, which is very flexible elastic rod. By measuring buckling angle, which is an angle between rotational axis and helical axis, we observe the effects of physical parameters on buckling of the hook.

  19. Helical propulsion in shear-thinning fluids

    CERN Document Server

    Gomez, Saul; Lauga, Eric; Zenit, Roberto

    2016-01-01

    Swimming microorganisms often have to propel in complex, non-Newtonian fluids. We carry out experiments with self-propelling helical swimmers driven by an externally rotating magnetic field in shear-thinning, inelastic fluids. Similarly to swimming in a Newtonian fluid, we obtain for each fluid a locomotion speed which scales linearly with the rotation frequency of the swimmer, but with a prefactor which depends on the power index of the fluid. The fluid is seen to always increase the swimming speed of the helix, up to 50% faster and thus the strongest of such type reported to date. The maximum relative increase for a fluid power index of around 0.6. Using simple scalings, we argue that the speed increase is not due to the local decrease of the flow viscosity around the helical filament but hypothesise instead that it originates from confinement-like effect due to viscosity stratification around the swimmer.

  20. Helical Muon Beam Cooling Channel Engineering Design

    Energy Technology Data Exchange (ETDEWEB)

    Kashikhin, V.S.; Lopes, M.L.; Romanov, G.V.; Tartaglia, M.A.; Yonehara, K.; Yu, M.; Zlobin, A.V.; /Fermilab; Flanagan, G.; Johnson, R.P.; Kazakevich, G.M.; Marhauser, F.; /MUONS Inc., Batavia

    2012-05-01

    The Helical Cooling Channel (HCC), a novel technique for six-dimensional (6D) ionization cooling of muon beams, has shown considerable promise based on analytic and simulation studies. However, the implementation of this revolutionary method of muon cooling requires new techniques for the integration of hydrogen-pressurized, high-power RF cavities into the low-temperature superconducting magnets of the HCC. We present the progress toward a conceptual design for the integration of 805 MHz RF cavities into a 10 T Nb{sub 3}Sn based HCC test section. We include discussions on the pressure and thermal barriers needed within the cryostat to maintain operation of the magnet at 4.2 K while operating the RF and energy absorber at a higher temperature. Additionally, we include progress on the Nb{sub 3}Sn helical solenoid design.

  1. Field of a helical Siberian Snake

    Energy Technology Data Exchange (ETDEWEB)

    Luccio, A. [Brookhaven National Lab., Upton, NY (United States)

    1995-02-01

    To preserve the spin polarization of a beam of high energy protons in a circular accelerator, magnets with periodic magnetic field, called Siberian Snakes are being used. Recently, it was proposed to build Siberian Snakes with superconducting helical dipoles. In a helical, or twisted dipole, the magnetic field is perpendicular to the axis of the helix and rotates around it as one proceeds along the magnet. In an engineering study of a 4 Tesla helical snake, the coil geometry is derived, by twisting, from the geometry of a cosine superconducting dipole. While waiting for magnetic measurement data on such a prototype, an analytical expression for the field of the helice is important, to calculate the particle trajectories and the spin precession in the helix. This model will also allow to determine the optical characteristics of the snake, as an insertion in the lattice of the accelerator. In particular, one can calculate the integrated multipoles through the magnet and the equivalent transfer matrix. An expression for the field in the helix body, i.e., excluding the fringe field was given in a classical paper. An alternate expression can be found by elaborating on the treatment of the field of a transverse wiggler obtained under the rather general conditions that the variables are separable. This expression exactly satisfies Maxwell`s div and curl equations for a stationary field, {del} {center_dot} B = 0, {del} x B = 0. This approach is useful in that it will allow one to use much of the work already done on the problem of inserting wigglers and undulators in the lattice of a circular accelerator.

  2. Automatic generation of tree level helicity amplitudes

    CERN Document Server

    Stelzer, T

    1994-01-01

    The program MadGraph is presented which automatically generates postscript Feynman diagrams and Fortran code to calculate arbitrary tree level helicity amplitudes by calling HELAS[1] subroutines. The program is written in Fortran and is available in Unix and VMS versions. MadGraph currently includes standard model interactions of QCD and QFD, but is easily modified to include additional models such as supersymmetry.

  3. Droplets climbing a rotating helical fiber

    CERN Document Server

    Texier, Baptiste Darbois

    2015-01-01

    A liquid droplet is placed on a rotating helical fiber. We find that the droplet may slide down, attach or climb up the fiber. We inspect experimentally the domain of existence of these three behaviors as a function of the geometrical characteristics of the fiber, its angle relatively to the horizontal, the wetting properties of the fluid and the rotating speed of the helix. A theoretical model is proposed in order to capture the boundaries of the experimental phase diagram.

  4. Helicity formalism for spin-2 particles

    Energy Technology Data Exchange (ETDEWEB)

    Gleisberg, Tanju [Institut fuer Theoretische Physik, TU Dresden, D-01062 Dresden (Germany); Physics Department, University of Florida, Gainesville, FL 32611 (United States); Krauss, Frank [Theory Division, CERN, CH-1211 Geneva 23 (Switzerland); Matchev, Konstantin T. [Physics Department, University of Florida, Gainesville, FL 32611 (United States) and LEPP, Cornell University, Ithaca, NY 14853 (United States)]. E-mail: matchev@mail.lns.cornell.edu; Schaelicke, Andreas [Institut fuer Theoretische Physik, TU Dresden, D-01062 Dresden (Germany); Schumann, Steffen [Institut fuer Theoretische Physik, TU Dresden, D-01062 Dresden (Germany); Soff, Gerhard [Institut fuer theoretische Physik, TU Dresden, D-01062 Dresden (Germany)

    2003-09-01

    We develop the helicity formalism for spin-2 particles and apply it to the case of gravity in flat extra dimensions. We then implement the large extra dimensions scenario of Arkani-Hamed, Dimopoulos and Dvali in the program AMEGIC++, allowing for an easy calculation of arbitrary processes involving the emission or exchange of gravitons. We complete the set of Feynman rules derived by Han, Lykken and Zhang, and perform several consistency checks of our implementation. (author)

  5. Physics of collapses in toroidal helical plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Kimitaka [National Inst. for Fusion Science, Toki, Gifu (Japan); Itoh, Sanae; Fukuyama, Atsushi; Yagi, Masatoshi

    1998-12-31

    Theoretical model for the collapse events in toroidal helical plasmas with magnetic hill is presented. There exists a turbulent-turbulent transition at a critical pressure gradient, leading to a sudden increase of the anomalous transport. When the magnetic shear is low, the nonlinear excitation of the global mode is possible. This model explains an abrupt growth of the perturbations, i.e., the trigger phenomena. Achievable limit of the plasma beta value is discussed. (author)

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much like other x-ray examinations. Different ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... a sudden severe headache. a blood clot or bleeding within the brain shortly after a patient exhibits symptoms of a stroke. a ... CT scanning may eliminate the need for exploratory surgery and surgical biopsy. No radiation remains in a patient's body after a CT examination. X-rays used in CT ...

  10. CT angiography and CT perfusion in acute ischemic stroke

    NARCIS (Netherlands)

    Seeters, T. van

    2016-01-01

    CT angiography and CT perfusion are used in patients with acute ischemic stroke for diagnostic purposes and to select patients for treatment. In this thesis, the reproducibility of CT angiography and CT perfusion is examined, the additional value of CT angiography and CT perfusion for stroke outcome

  11. Three-dimensional helical computed tomographic evaluation of three obturation techniques: In vitro study

    Directory of Open Access Journals (Sweden)

    M Chokkalingam

    2011-01-01

    Full Text Available Aim: The purpose of this study was to evaluate the adequacy of three obturation techniques namely lateral condensation, EQ Fil (backfill obturation and thermafil (core carrier obturation techniques using three-dimensional (3D helical computed tomography (CT by volume rendering method. Materials and Methods: Thirty freshly extracted teeth were randomly divided into three groups of 10 teeth each. Biomechanical preparation was done in all the teeth using rotary instruments. All three sets of teeth were placed in helical CT slice scanner and were imaged before obturation. The three sets were then obturated by following methods: Group I: lateral condensation, Group II: EQ Fil (backfill and Group III: thermafil (core carrier obturation.Volume of the pulp chamber and gutta-percha after obturation were calculated using volume rendering technique and adequacy of the obturation techniques were calculated. Statistical Analysis Used: One-way ANOVA and Multiple-Range Tukey Test by Tukey-HSD procedure Results: Mean change in lateral condensation (0.005±0.002 was significantly higher than that of thermafil obturation (0.002±0.001 [P<0.05]. Conclusions: Conventional lateral condensation technique showed maximal inadequacy of obturation and thermafil obturation technique showed the least inadequacy of obturation when the volume of the specimens were calculated and reconstructed

  12. Custom-Made Computer-Aided-Design/Computer-Aided-Manufacturing Biphasic Calcium-Phosphate Scaffold for Augmentation of an Atrophic Mandibular Anterior Ridge

    Directory of Open Access Journals (Sweden)

    Francesco Guido Mangano

    2015-01-01

    Full Text Available This report documents the clinical, radiographic, and histologic outcome of a custom-made computer-aided-design/computer-aided-manufactured (CAD/CAM scaffold used for the alveolar ridge augmentation of a severely atrophic anterior mandible. Computed tomographic (CT images of an atrophic anterior mandible were acquired and modified into a 3-dimensional (3D reconstruction model; this was transferred to a CAD program, where a custom-made scaffold was designed. CAM software generated a set of tool-paths for the manufacture of the scaffold on a computer-numerical-control milling machine into the exact shape of the 3D design. A custom-made scaffold was milled from a synthetic micromacroporous biphasic calcium phosphate (BCP block. The scaffold closely matched the shape of the defect: this helped to reduce the time for the surgery and contributed to good healing. One year later, newly formed and well-integrated bone was clinically available, and two implants (AnyRidge, MegaGen, Gyeongbuk, South Korea were placed. The histologic samples retrieved from the implant sites revealed compact mature bone undergoing remodelling, marrow spaces, and newly formed trabecular bone surrounded by residual BCP particles. This study demonstrates that custom-made scaffolds can be fabricated by combining CT scans and CAD/CAM techniques. Further studies on a larger sample of patients are needed to confirm these results.

  13. CT Diagnosis of Fitz-Hugh and Curtis Syndrome: Value of the Arterial Phase Scan

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Seung Ho; Kim, Myeong Jin; Lim, Joon Seok; Kim, Joo Hee; Kim, Ki Whang [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2007-02-15

    We wanted to evaluate the role of the arterial phase (AP) together with the portal venous phase (PP) scans in the diagnosis of Fitz-Hugh-Curtis syndrome (FHCS) with using computed tomography (CT). Twenty-five patients with FHCS and 25 women presenting with non-specifically diagnosed acute abdominal pain and who underwent biphasic CT examinations were evaluated. The AP scan included the upper abdomen, and the PP scan included the whole abdomen. Two radiologists blindly and retrospectively reviewed the PP scans first and then they reviewed the AP plus PP scans. The diagnostic accuracy of FHCS on each image set was compared for each reader by analyzing the area under the receiver operating characteristic curve (Az). Weighted kappa (wk) statistics were used to measure the interobserver agreement for the presence of CT signs of the pelvic inflammatory disease (PID) on the PP images and FHCS as the diagnosis based on the increased perihepatic enhancement on both sets of images. The individual diagnostic accuracy of FHCS was higher on the biphasic images (Az = 0.905 and 0.942 for reader 1 and 2, respectively) than on the PP images alone (Az = 0.806 and 0.706, respectively). The interobserver agreement for the presence of PID on the PP images was moderate (wk = 0.530). The interobserver agreement for FHCS as the diagnosis was moderate on only the PP images (wk = 0.413), but it was substantial on the biphasic images (wk 0.719). Inclusion of the AP scan is helpful to depict the increased perihepatic enhancement, and it improves the diagnostic accuracy of FHCS on CT.

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  15. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ...

  16. Propulsion by Helical Strips in Circular Channels

    Science.gov (United States)

    Yesilyurt, Serhat; Demir, Ebru

    2016-11-01

    Progress in manufacturing techniques avails the production of artificial micro swimmers (AMS) in various shapes and sizes. There are numerous studies on the generation of efficient locomotion by means of helical tails with circular cross-sections. This work focuses on locomotion with helical strips in circular channels. A CFD model is used to analyze the effects of geometric parameters and the radius of the channel on swimming velocity of infinite helical-strips in circular channels. Results show that there is an optimum wavelength that depends on thickness to channel radius ratio, suggesting that these parameters need to be optimized simultaneously. With constant torque, thinner strips swim faster, whereas under constant angular velocity application, thicker strips (in radial direction) prevail. As width approaches the wavelength, velocity decreases under both conditions, unless a magnetically coated tail is simulated, for which width has an optimum value. Increasing channel radius to helix amplitude ratio increases the velocity up to a maximum and after a slight drop, saturation occurs as bulk swimming conditions are approached.

  17. Mechanical Resonances of Helically Coiled Carbon Nanowires

    Science.gov (United States)

    Saini, D.; Behlow, H.; Podila, R.; Dickel, D.; Pillai, B.; Skove, M. J.; Serkiz, S. M.; Rao, A. M.

    2014-07-01

    Despite their wide spread applications, the mechanical behavior of helically coiled structures has evaded an accurate understanding at any length scale (nano to macro) mainly due to their geometrical complexity. The advent of helically coiled micro/nanoscale structures in nano-robotics, nano-inductors, and impact protection coatings has necessitated the development of new methodologies for determining their shear and tensile properties. Accordingly, we developed a synergistic protocol which (i) integrates analytical, numerical (i.e., finite element using COMSOL®) and experimental (harmonic detection of resonance; HDR) methods to obtain an empirically validated closed form expression for the shear modulus and resonance frequency of a singly clamped helically coiled carbon nanowire (HCNW), and (ii) circumvents the need for solving 12th order differential equations. From the experimental standpoint, a visual detection of resonances (using in situ scanning electron microscopy) combined with HDR revealed intriguing non-planar resonance modes at much lower driving forces relative to those needed for linear carbon nanotube cantilevers. Interestingly, despite the presence of mechanical and geometrical nonlinearities in the HCNW resonance behavior the ratio of the first two transverse modes f2/f1 was found to be similar to the ratio predicted by the Euler-Bernoulli theorem for linear cantilevers.

  18. Superconducting Helical Snake Magnet for the AGS

    CERN Document Server

    Willen, Erich; Escallier, John; Ganetis, George; Ghosh, Arup; Gupta, Ramesh C; Harrison, Michael; Jain, Animesh K; Luccio, Alfredo U; MacKay, William W; Marone, Andrew; Muratore, Joseph F; Okamura, Masahiro; Plate, Stephen R; Roser, Thomas; Tsoupas, Nicholaos; Wanderer, Peter

    2005-01-01

    A superconducting helical magnet has been built for polarized proton acceleration in the Brookhaven AGS. This "partial Snake" magnet will help to reduce the loss of polarization of the beam due to machine resonances. It is a 3 T magnet some 1940 mm in magnetic length in which the dipole field rotates with a pitch of 0.2053 degrees/mm for 1154 mm in the center and a pitch of 0.3920 degrees/mm for 393 mm in each end. The coil cross-section is made of two slotted cylinders containing superconductor. In order to minimize residual offsets and deflections of the beam on its orbit through the Snake, a careful balancing of the coil parameters was necessary. In addition to the main helical coils, a solenoid winding was built on the cold bore tube inside the main coils to compensate for the axial component of the field that is experienced by the beam when it is off-axis in this helical magnet. Also, two dipole corrector magnets were placed on the same tube with the solenoid. A low heat leak cryostat was built so that t...

  19. SUPERCONDUCTING HELICAL SNAKE MAGNET FOR THE AGS.

    Energy Technology Data Exchange (ETDEWEB)

    WILLEN, E.; ANERELLA, M.; ESCALLIER, G.; GANETIS, G.; GHOSH, A.; GUPTA, R.; HARRISON, M.; JAIN, A.; LUCCIO, A.; MACKAY, W.; MARONE, A.; MURATORE, J.; PLATE, S.; ET AL.

    2005-05-16

    A superconducting helical magnet has been built for polarized proton acceleration in the Brookhaven AGS. This ''partial Snake'' magnet will help to reduce the loss of polarization of the beam due to machine resonances. It is a 3 T magnet some 1940 mm in magnetic length in which the dipole field rotates with a pitch of 0.2053 degrees/mm for 1154 mm in the center and a pitch of 0.3920 degrees/mm for 393 mm in each end. The coil cross-section is made of two slotted cylinders containing superconductor. In order to minimize residual offsets and deflections of the beam on its orbit through the Snake, a careful balancing of the coil parameters was necessary. In addition to the main helical coils, a solenoid winding was built on the cold bore tube inside the main coils to compensate for the axial component of the field that is experienced by the beam when it is off-axis in this helical magnet. Also, two dipole corrector magnets were placed on the same tube with the solenoid. A low heat leak cryostat was built so that the magnet can operate in the AGS cooled by several cryocoolers. The design, construction and performance of this unique magnet will be summarized.

  20. Galactic dynamos supported by magnetic helicity fluxes

    CERN Document Server

    Sur, S; Subramanian, K; Sur, Sharanya; Shukurov, Anvar; Subramanian, Kandaswamy

    2006-01-01

    We present a simple semi-analytical model of nonlinear, mean-field galactic dynamos and use it to study the effects of various magnetic helicity fluxes. The dynamo equations are reduced using the `no-$z$' approximation to a nonlinear system of ordinary differential equations in time; we demonstrate that the model reproduces accurately earlier results, including those where nonlinear behaviour is driven by a magnetic helicity flux. We discuss the implications and interplay of two types of magnetic helicity flux, one produced by advection (e.g., due to the galactic fountain or wind) and the other, arising from anisotropy of turbulence as suggested by Vishniac & Cho(2001). We argue that the latter is significant if the galactic differential rotation is strong enough: in our model, for $\\Rw\\la-10$ in terms of the corresponding turbulent magnetic Reynolds number. We confirm that the intensity of gas outflow from the galactic disc optimal for the dynamo action is close to that expected for normal spiral galaxie...

  1. Buckling transition in long α-helices

    Energy Technology Data Exchange (ETDEWEB)

    Palenčár, Peter; Bleha, Tomáš, E-mail: bleha@savba.sk [Polymer Institute, Slovak Academy of Sciences, 845 41 Bratislava (Slovakia)

    2014-11-07

    The treatment of bending and buckling of stiff biopolymer filaments by the popular worm-like chain model does not provide adequate understanding of these processes at the microscopic level. Thus, we have used the atomistic molecular-dynamic simulations and the Amber03 force field to examine the compression buckling of α-helix (AH) filaments at room temperature. It was found that the buckling instability occurs in AHs at the critical force f{sub c} in the range of tens of pN depending on the AH length. The decrease of the force f{sub c} with the contour length follows the prediction of the classic thin rod theory. At the force f{sub c} the helical filament undergoes the swift and irreversible transition from the smoothly bent structure to the buckled one. A sharp kink in the AH contour arises at the transition, accompanied by the disruption of the hydrogen bonds in its vicinity. The kink defect brings in an effective softening of the AH molecule at buckling. Nonbonded interactions between helical branches drive the rearrangement of a kinked AH into the ultimate buckled structure of a compact helical hairpin described earlier in the literature.

  2. Differential geometry of proteins. Helical approximations.

    Science.gov (United States)

    Louie, A H; Somorjai, R L

    1983-07-25

    We regard a protein molecule as a geometric object, and in a first approximation represent it as a regular parametrized space curve passing through its alpha-carbon atoms (the backbone). In an earlier paper we argued that the regular patterns of secondary structures of proteins (morphons) correspond to geodesics on minimal surfaces. In this paper we discuss methods of recognizing these morphons on space curves that represent the protein backbone conformation. The mathematical tool we employ is the differential geometry of curves and surfaces. We introduce a natural approximation of backbone space curves in terms of helical approximating elements and present a computer algorithm to implement the approximation. Simple recognition criteria are given for the various morphons of proteins. These are incorporated into our helical approximation algorithm, together with more non-local criteria for the recognition of beta-sheet topologies. The method and the algorithm are illustrated with several examples of representative proteins. Generalizations of the helical approximation method are considered and their possible implications for protein energetics are sketched.

  3. Phase conversion of tricalcium phosphate into Ca-deficient apatite during sintering of hydroxyapatite-tricalcium phosphate biphasic ceramics.

    Science.gov (United States)

    Kong, Young-Min; Kim, Hyoun-Ee; Kim, Hae-Won

    2008-02-01

    In this study, we report a new observation on the phase conversion that occurs during the sintering of hydroxyapatite (HA)-tricalcium phosphate (TCP) biphasic ceramics. During the sintering of the HA-TCP mixture powders, a large amount of TCP was converted into HA, as detected by X-ray diffraction. The amount of TCP transformed into HA was approximately 10-90% of that initially added. From the electron probe microscopy analysis, the HA transformed from TCP was found to be Ca-deficient with Ca/P ratios of 1.62-1.64. The dissolution behavior and osteoblastic responses in a series of HA-TCP biphasic ceramics (10-90% TCP) were assessed. The solubility of the HA-TCP biphasic ceramics was intermediate between that of the HA and TCP pure ceramics. However, in the case of the HA-90% TCP biphasic ceramic, the solubility was even higher than that of pure TCP. The cell proliferation and alkaline phosphatase activity of the cells on the biphasic ceramics were lower than those on pure HA, but higher than those on pure TCP. However, particularly in the HA-50% TCP biphasic composition, the cellular responses were significantly higher than those on pure HA. It is considered that the Ca-deficient apatite newly formed from the TCP may affect in some way the solubility and biological properties of the HA-TCP biphasic ceramics.

  4. NUMERICAL INVESTIGATION FOR THE HEAT TRANSFER ENHANCEMENT IN HELICAL CONE COILS OVER ORDINARY HELICAL COILS

    Directory of Open Access Journals (Sweden)

    M. M. ABO ELAZM

    2013-02-01

    Full Text Available This numerical research is introducing the concept of helical cone coils and their enhanced heat transfer characteristics compared to the ordinary helical coils. Helical and spiral coils are known to have better heat and mass transfer than straight tubes, which is attributed to the generation of a vortex at the helical coil known as Dean Vortex. The Dean number which is a dimensionless number used to describe the Dean vortex is a function of Reynolds number and the square root of the curvature ratio, so varying the curvature ratio for the same coil would vary the Dean number. Two scenarios were adopted to study the effect of changing the taper angle (curvature ratio on the heat transfer characteristics of the coil; the commercial software FLUENT was used in the investigation. It was found that Nusselt number increased with increasing the taper angle. A MATLAB code was built based on empirical correlation of Manlapaz and Churchill for ordinary helical coils to calculate the Nusselt number at each coil turn, and then calculate the average Nusselt number for the entire coil turns, the CFD simulation results were found acceptable when compared with the MATLAB results.

  5. Helicity and alpha-effect by current-driven instabilities of helical magnetic fields

    CERN Document Server

    Gellert, M; Hollerbach, R

    2011-01-01

    Helical magnetic background fields with adjustable pitch angle are imposed on a conducting fluid in a differentially rotating cylindrical container. The small-scale kinetic and current helicities are calculated for various field geometries, and shown to have the opposite sign as the helicity of the large-scale field. These helicities and also the corresponding $\\alpha$-effect scale with the current helicity of the background field. The $\\alpha$-tensor is highly anisotropic as the components $\\alpha_{\\phi\\phi}$ and $\\alpha_{zz}$ have opposite signs. The amplitudes of the azimuthal $\\alpha$-effect computed with the cylindrical 3D MHD code are so small that the operation of an $\\alpha\\Omega$ dynamo on the basis of the current-driven, kink-type instabilities of toroidal fields is highly questionable. In any case the low value of the $\\alpha$-effect would lead to very long growth times of a dynamo in the radiation zone of the Sun and early-type stars of the order of mega-years.

  6. The Effects of Spatial Smoothing on Solar Magnetic Helicity Parameters and the Hemispheric Helicity Sign Rule

    Science.gov (United States)

    Koch Ocker, Stella; Petrie, Gordon

    2016-12-01

    The hemispheric preference for negative/positive helicity to occur in the northern/southern solar hemisphere provides clues to the causes of twisted, flaring magnetic fields. Previous studies on the hemisphere rule may have been affected by seeing from atmospheric turbulence. Using Hinode/SOT-SP data spanning 2006-2013, we studied the effects of two spatial smoothing tests that imitate atmospheric seeing: noise reduction by ignoring pixel values weaker than the estimated noise threshold, and Gaussian spatial smoothing. We studied in detail the effects of atmospheric seeing on the helicity distributions across various field strengths for active regions (ARs) NOAA 11158 and NOAA 11243, in addition to studying the average helicities of 179 ARs with and without smoothing. We found that, rather than changing trends in the helicity distributions, spatial smoothing modified existing trends by reducing random noise and by regressing outliers toward the mean, or removing them altogether. Furthermore, the average helicity parameter values of the 179 ARs did not conform to the hemisphere rule: independent of smoothing, the weak-vertical-field values tended to be negative in both hemispheres, and the strong-vertical-field values tended to be positive, especially in the south. We conclude that spatial smoothing does not significantly affect the overall statistics for space-based data, and thus seeing from atmospheric turbulence seems not to have significantly affected previous studies’ ground-based results on the hemisphere rule.

  7. PERFORMANCE ANALYSIS OF A HELICAL SAVONIUS ROTOR WITHOUT SHAFT AT 45° TWIST ANGLE USING CFD

    Directory of Open Access Journals (Sweden)

    Bachu Deb

    2013-06-01

    Full Text Available Helical Savonius rotor exhibits better performance characteristics at all the rotor angles compared to conventional Savonius rotor. However studies related to the performance measurement and flow physics of such rotor are very scarce. Keeping this in view, in this paper, a three dimensional Computational Fluid Dynamics analysis using commercial Fluent 6.2 software was done to predict the performance of a two-bucket helical Savonius rotor without shaft and with end plates in a complete cycle of rotation. A two-bucket helical Savonius rotor having height of 60 cm and diameter of 17 cm with 45° bucket twist angle was designed using Gambit. The buckets were connected at the top and bottom circular end plates, which are 1.1 times the rotor diameter. The k-ε turbulence model with second order upwind discretization scheme was adopted with standard wall condition. Power coefficients (Cp and torque coefficients (Ct at different tip speed ratios were evaluated at different rotor angles. From the investigation, it was observed that power coefficient increased with increase of tip speed ratio up to an optimum limit, but then decreased even further tip speed ratio was increased. Further investigation was done on the variations of Cp & Ct in a complete cycle of rotation from 0° to 360° in a step of 45° rotor corresponding to the optimum tip speed ratio. The value of Cp at all the rotor angles is positive. Moreover, velocity magnitude contours were analyzed for each rotor angle and it could be concluded that high aerodynamic torque and power can be expected when the rotor is positioned at 45º & 90º with respect to incoming flow.

  8. PERFORMANCE ANALYSIS OF A HELICAL SAVONIUS ROTOR WITHOUT SHAFT AT 45° TWIST ANGLE USING CFD

    Directory of Open Access Journals (Sweden)

    Bachu Deb

    2013-01-01

    Full Text Available Helical Savonius rotor exhibits better performance characteristics at all the rotor angles compared to conventional Savonius rotor. However studies related to the performance measurement and flow physics of such rotor are very scarce. Keeping this in view, in this paper, a three dimensional Computational Fluid Dynamics analysis using commercial Fluent 6.2 software was done to predict the performance of a two-bucket helical Savonius rotor without shaft and with end plates in a complete cycle of rotation. A two-bucket helical Savonius rotor having height of 60 cm and diameter of 17 cm with 45° bucket twist angle was designed using Gambit. The buckets were connected at the top and bottom circular end plates, which are 1.1 times the rotor diameter. The k- ε turbulence model with second order upwind discretization scheme was adopted with standard wall condition. Power coefficients (Cp and torque coefficients (Ct at different tip speed ratios were evaluated at different rotor angles. From the investigation, it was observed that power coefficient increased with increase of tip speed ratio up to an optimum limit, but then decreased even further tip speed ratio was increased. Further investigation was done on the variations of Cp & Ct in a complete cycle of rotation from 0° to 360° in a step of 45° rotor corresponding to the optimum tip speed ratio. The value of Cp at all the rotor angles is positive. Moreover, velocity magnitude contours were analyzed for each rotor angle and it could be concluded that high aerodynamic torque and power can be expected when the rotor is positioned at 45º & 90º with respect to incoming flow.

  9. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  10. Water/Oil Biphasic Hydroformylation of Higher Olefins over a TPPTS-Rh/SiO2 Catalyst

    Institute of Scientific and Technical Information of China (English)

    Hejun Zhu; Yunjie Ding; Fu Yang; Li Yan; Jianmin Xiong; Hongmei Yin; Liwu Lin

    2004-01-01

    A novel TPPTS-Rh/SiO2 catalyst, prepared by directly modifying a heterogeneous highsurface-area Rh/SiO2 catalyst with water-soluble TPPTS ligands, could decrease the resistance of mass transfer in water/oil biphasic media for the hydroformylation of higher olefins. The catalytic performance for hydroformylation on this biphasic TPPTS-Rh/SiO2 catalyst system was higher than those of the traditional biphasic HRhCO(TPPTS)3 systems, owing to the chemical bonds between the highly dispersed Rh metal particles and the TPPTS ligands. The catalyst system is applicable for hydroformylation of higher olefins such as 1-dodecene.

  11. Cryo-EM Structure Determination Using Segmented Helical Image Reconstruction.

    Science.gov (United States)

    Fromm, S A; Sachse, C

    2016-01-01

    Treating helices as single-particle-like segments followed by helical image reconstruction has become the method of choice for high-resolution structure determination of well-ordered helical viruses as well as flexible filaments. In this review, we will illustrate how the combination of latest hardware developments with optimized image processing routines have led to a series of near-atomic resolution structures of helical assemblies. Originally, the treatment of helices as a sequence of segments followed by Fourier-Bessel reconstruction revealed the potential to determine near-atomic resolution structures from helical specimens. In the meantime, real-space image processing of helices in a stack of single particles was developed and enabled the structure determination of specimens that resisted classical Fourier helical reconstruction and also facilitated high-resolution structure determination. Despite the progress in real-space analysis, the combination of Fourier and real-space processing is still commonly used to better estimate the symmetry parameters as the imposition of the correct helical symmetry is essential for high-resolution structure determination. Recent hardware advancement by the introduction of direct electron detectors has significantly enhanced the image quality and together with improved image processing procedures has made segmented helical reconstruction a very productive cryo-EM structure determination method.

  12. Helical muon beam cooling channel engineering design

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland [Muons, Inc., Batavia, IL (United States)

    2015-08-07

    The Helical Cooling Channel (HCC) achieves effective ionization cooling of the six-dimensional (6d) phase space of a muon beam by means of a series of 21st century inventions. In the HCC, hydrogen-pressurized RF cavities enable high RF gradients in strong external magnetic fields. The theory of the HCC, which requires a magnetic field with solenoid, helical dipole, and helical quadrupole components, demonstrates that dispersion in the gaseous hydrogen energy absorber provides effective emittance exchange to enable longitudinal ionization cooling. The 10-year development of a practical implementation of a muon-beam cooling device has involved a series of technical innovations and experiments that imply that an HCC of less than 300 m length can cool the 6d emittance of a muon beam by six orders of magnitude. We describe the design and construction plans for a prototype HCC module based on oxygen-doped hydrogen-pressurized RF cavities that are loaded with dielectric, fed by magnetrons, and operate in a superconducting helical solenoid magnet. The first phase of this project saw the development of a conceptual design for the integration of 805 MHz RF cavities into a 10 T Nb3Sn based HS test section. Two very novel ideas are required to realize the design. The first idea is the use of dielectric inserts in the RF cavities to make them smaller for a given frequency so that the cavities and associated plumbing easily fit inside the magnet cryostat. Calculations indicate that heat loads will be tolerable, while RF breakdown of the dielectric inserts will be suppressed by the pressurized hydrogen gas. The second new idea is the use of a multi-layer Nb3Sn helical solenoid. The technology demonstrations for the two aforementioned key components of a 10T, 805 MHz HCC were begun in this project. The work load in the Fermilab Technical Division made it difficult to test a multi-layer Nb3Sn solenoid as originally planned. Instead, a complementary project was approved by the DOE

  13. Helical muon beam cooling channel engineering design

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland [Muons, Inc., Batavia, IL (United States)

    2015-08-07

    The Helical Cooling Channel (HCC) achieves effective ionization cooling of the six-dimensional (6d) phase space of a muon beam by means of a series of 21st century inventions. In the HCC, hydrogen-pressurized RF cavities enable high RF gradients in strong external magnetic fields. The theory of the HCC, which requires a magnetic field with solenoid, helical dipole, and helical quadrupole components, demonstrates that dispersion in the gaseous hydrogen energy absorber provides effective emittance exchange to enable longitudinal ionization cooling. The 10-year development of a practical implementation of a muon-beam cooling device has involved a series of technical innovations and experiments that imply that an HCC of less than 300 m length can cool the 6d emittance of a muon beam by six orders of magnitude. We describe the design and construction plans for a prototype HCC module based on oxygen-doped hydrogen-pressurized RF cavities that are loaded with dielectric, fed by magnetrons, and operate in a superconducting helical solenoid magnet. The first phase of this project saw the development of a conceptual design for the integration of 805 MHz RF cavities into a 10 T Nb3Sn-based HS test section. Two very novel ideas are required to realize the design. The first idea is the use of dielectric inserts in the RF cavities to make them smaller for a given frequency so that the cavities and associated plumbing easily fit inside the magnet cryostat. Calculations indicate that heat loads will be tolerable, while RF breakdown of the dielectric inserts will be suppressed by the pressurized hydrogen gas. The second new idea is the use of a multi-layer Nb3Sn helical solenoid. The technology demonstrations for the two aforementioned key components of a 10T, 805 MHz HCC were begun in this project. The work load in the Fermilab Technical Division made it difficult to test a multi-layer Nb3Sn solenoid as originally planned. Instead, a complementary

  14. Helical electron-beam microbunching by harmonic coupling in a helical undulator.

    Science.gov (United States)

    Hemsing, E; Musumeci, P; Reiche, S; Tikhoplav, R; Marinelli, A; Rosenzweig, J B; Gover, A

    2009-05-01

    Microbunching of a relativistic electron beam into a helix is examined analytically and in simulation. Helical microbunching is shown to occur naturally when an e beam interacts resonantly at the harmonics of the combined field of a helical magnetic undulator and an axisymmetric input laser beam. This type of interaction is proposed as a method to generate a strongly prebunched e beam for coherent emission of light with orbital angular momentum at virtually any wavelength. The results from the linear microbunching theory show excellent agreement with three-dimensional numerical simulations.

  15. Eikonal Slant Helices and Eikonal Darboux Helices In 3-Dimensional Riemannian Manifolds

    OpenAIRE

    Önder, Mehmet; Ziplar, Evren; Kaya, Onur

    2013-01-01

    In this study, we give definitions and characterizations of eikonal slant helix curves, eikonal Darboux helices and non-normed eikonal Darboux helices in three dimensional Riemannian manifold 3 M . We show that every eikonal slant helix is also an eikonal Darboux helix. Furthermore, we obtain that if the curve a is a non-normed eikonal Darboux helix, then a is an eikonal slant helix if and only if k 2 +t 2 = constant, where k and t are curvature and torsion of a, respectively.

  16. Coordination chemistry strategies for dynamic helicates: time-programmable chirality switching with labile and inert metal helicates.

    Science.gov (United States)

    Miyake, Hiroyuki; Tsukube, Hiroshi

    2012-11-01

    'Chirality switching' is one of the most important chemical processes controlling many biological systems. DNAs and proteins often work as time-programmed functional helices, in which specific external stimuli alter the helical direction and tune the time scale of subsequent events. Although a variety of organic foldamers and their hybrids with natural helices have been developed, we highlight coordination chemistry strategies for development of structurally and functionally defined metal helicates. These metal helicates have characteristic coordination geometries, redox reactivities and spectroscopic/magnetic properties as well as complex chiralities. Several kinds of inert metal helicates maintain rigid helical structures and their stereoisomers are separable by optical resolution techniques, while labile metal helicates offer dynamic inversion of their helical structures via non-covalent interactions with external chemical signals. The latter particularly have dynamically ordered helical structures, which are controlled by the combinations of metal centres and chiral ligands. They further function as time-programmable switches of chirality-derived dynamic rotations, translations, stretching and shape flipping, which are useful applications in nanoscience and related technology.

  17. A Helical Polymer with a Cooperative Response to Chiral Information

    Science.gov (United States)

    Green, Mark M.; Peterson, Norman C.; Sato, Takahiro; Teramoto, Akio; Cook, Robert; Lifson, Shneior

    1995-06-01

    Polyisocyanates, long studied as theoretical models for wormlike chains in dilute solution and liquid crystals, differ from their biological helical analogs in the absence of a predetermined helical sense. These polymers have an unusual sensitivity to chiral effects that arises from a structure in which alternating right- and left-handed long helical blocks are separated by infrequent and mobile helical reversals. Statistical thermodynamic methods yield an exact description of the polymer and the cooperative nature of its chiral properties. Minute energies that favor one of the helical senses drive easily measurable conformational changes, even though such energies may be extremely difficult to calculate from structural theory. In addition, the chiral nature of the polymer can be used to test theoretical ideas concerned with cholesteric liquid crystals, one of which solves the problem of assigning the helical sense.

  18. Hydrodynamic Helical Orientations of Nanofibers in a Vortex

    Directory of Open Access Journals (Sweden)

    Akihiko Tsuda

    2014-05-01

    Full Text Available In this review article, I report our recent studies on spectroscopic visualizations of macroscopic helical alignments of nanofibers in vortex flows. Our designed supramolecular nanofibers, formed through self-assemblies of dye molecules, helically align in torsional flows of a vortex generated by mechanical rotary stirring of the sample solutions. The nanofiber, formed through bundling of linear supramolecular polymers, aligns equally in right- and left-handed vortex flows. However, in contrast, a one-handedly twisted nanofiber, formed through helical bundling of the supramolecular polymers, shows unequal helical alignments in these torsional flows. When the helical handedness of the nanofiber matches that of the vortex flow, the nanofiber aligns more efficiently in the flowing fluid. Such phenomena are observed not only with the artificial helical supramolecular nanofibers but also with biological nanofibers such as double-stranded DNA.

  19. System assessment of helical reactors in comparison with tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, K.; Imagawa, S.; Muroga, T.; Sagara, A.; Okamura, S.

    2002-10-01

    A comparative assessment of tokamak and helical reactors has been performed using equivalent physics/engineering model and common costing model. Higher-temperature plasma operation is required in tokamak reactors to increase bootstrap current fraction and to reduce current-drive (CD) power. In helical systems, lower-temperature operation is feasible and desirable to reduce helical ripple transport. The capital cost of helical reactor is rather high, however, the cost of electricity (COE) is almost same as that of tokamak reactor because of smaller re-circulation power (no CD power) and less-frequent blanket replacement (lower neutron wall loading). The standard LHD-type helical reactor with 5% beta value is economically equivalent to the standard tokamak with 3% beta. The COE of lower-aspect ratio helical reactor is on the same level of high-{beta}{sub N} tokamak reactors. (author)

  20. Magnetoelectric-field helicities and reactive power flows

    CERN Document Server

    Kamenetskii, E O; Shavit, R

    2015-01-01

    The dual symmetry between the electric and magnetic fields underlies Maxwell's electrodynamics. Due to this symmetry one can describe topological properties of an electromagnetic field in free space and obtain the conservation law of optical (electromagnetic) helicity. What kind of the field helicity one can expect to see when the electromagnetic-field symmetry is broken? The near fields originated from small ferrite particles with magnetic dipolar mode (MDM) oscillations are the fields with the electric and magnetic components, but with broken dual (electric-magnetic) symmetry. These fields, called magnetoelectric (ME) fields, have topological properties different from such properties of electromagnetic fields. The helicity states of ME fields are topologically protected quantum like states. In this paper, we study the helicity properties of ME fields. We analyze conservation laws of the ME-field helicity and show that the helicity density is related to an imaginary part of the complex power flow density. We...