WorldWideScience

Sample records for biphasic current pulses

  1. Interferential and burst-modulated biphasic pulsed currents yield greater muscular force than Russian current.

    Science.gov (United States)

    Bellew, James W; Beiswanger, Zach; Freeman, Erica; Gaerte, Carrie; Trafton, Jane

    2012-07-01

    Previous data regarding neuromuscular electrical stimulation (NMES) have suggested that muscle torque production with interferential current (IFC) is inferior to Russian current; however, waveform parameters specific and critical to NMES were inconsistent, making interpretation of previous findings precarious. The purpose of this investigation was to compare muscle force production of three electrical stimulating waveforms when using equivalent stimulus parameters. The percent of maximal voluntary isometric knee extensor force (%MVIF) elicited using interferential, Russian, and burst-modulated biphasic pulsed currents were compared in 23 healthy college-aged subjects. A repeated measures single factor design in a university laboratory setting was used. A significant effect for waveform used was noted. Data showed significantly greater %MVIF of the knee extensors were obtained using IFC or burst-modulated BP current versus conventional Russian current. The results of this investigation suggest that IFC and burst-modulated BP current are viable waveform options for purposes of eliciting muscle force. These findings offer significant new evidence with strong clinical implications when selecting waveform parameters for elicitation of muscle force for NMES.

  2. Is there an Optimal Shape of the Defibrillation Shock: Constant Current vs. Pulsed Biphasic Waveforms

    Directory of Open Access Journals (Sweden)

    Ivan Dotsinsky

    2013-04-01

    Full Text Available Three waveforms for transthoracic defibrillation are assessed and compared: the Pulsed Biphasic Waveform (PBW, the Rectilinear Biphasic Waveform (RBW, and the "lossless" constant current (LLCC pulses. Two indices are introduced: 1 kf = W/W0 - the ratio between the delivered energy W and the energy W0 of a rectangular pulse with the same duration and electric charge; 2 ηC = W/WC0 - the level of utilizing the initially loaded capacitor energy WC0. The envisioned comparative study shows that ηC index is favorable for both PBW and LLCC, while kf of both RBW and LLCC demonstrates advantage over the PBW in the range of small inter-electrode thoracic impedances below 80 Ω. Some design considerations are also discussed. The attractive LLCC concept needs large and heavy inductive coil to support the constant current amplitude, besides it is capable to induce strong electromagnetic influences due to the complex current control. The RBW technology controls the delivery of current through a series of internal resistors which are, however, a source of high heat losses. The PBW implements controlled duty cycle of high-frequency chopped pulses to adapt the energy delivery in respect of the patient impedance measured at the beginning of the shock. PBW technology makes use of small capacitors which allows the construction of light weight and small-size portable devices for transthoracic defibrillation.

  3. Muscle force production with low and medium frequency burst modulated biphasic pulsed currents.

    Science.gov (United States)

    Bellew, James W; Sanders, Kyle; Schuman, Kristen; Barton, Matt

    2014-02-01

    Russian current, a medium frequency burst modulated alternating current (BMAC), is widely used for NMES, but has not been shown to elicit forces near voluntary maximum. In contrast, low frequency BMAC has been shown to produce greater force production than Russian and most recently, medium frequency burst modulated biphasic pulsed current (BMBPC) elicited greater force than Russian. Whether low frequency BMBPC yields greater force than medium frequency BMBPC is unknown. This study examined elicited forces using BMBPC with low and medium frequency carrier currents. A cross-over design where percent maximal isometric knee extensor forces (%MVIF) elicited using BMBPC with low or medium kilohertz carrier frequencies were compared in 23 subjects. Perceived discomfort was also assessed. Data were compared using paired samples t-tests. 98.4% of the MVIF was elicited with the low frequency BMBPC which was significantly greater (p current. Cohen's d effect size of 2.146 indicated a "huge effect". Perceived discomfort of the low frequency current was 5.7/10 and was significantly greater (p current (3.6/10). BMBPC with low frequency carrier current elicits forces approximating maximal volitional force. These findings offer new evidence with strong clinical implications when using NMES.

  4. Comparison of defibrillation efficacy using biphasic waveforms delivered from various capacitances/pulse widths.

    Science.gov (United States)

    Lin, J H; Stotts, L J; Rosborough, J P; Frederick, H

    1997-01-01

    The efficacy of the biphasic waveform shock for the defibrillation of the ventricular myocardium has been reported by researchers and physicians. Although many authors have suggested that biphasic waveforms delivered from lower capacitances and shorter pulse widths could result in the reduction of the energy required for successful defibrillation, no report has described the smallest capacitance and pulse width yielding the lowest DFT. In this study, we compared efficacies of the biphasic waveform shocks and DFT safety margins among five different capacitances (175 mu f, 125 mu f. 100 mu f. 75 mu f, and 50 mu f) combined with 1-3 pulse widths. These experiments performed in six dogs used an endocardial lead/subcutaneous patch defibrillation electrode system. The average DFTs at E50 for 175 mu f (6.5/3.5 ms), 125 mu f (6.5/3.5 ms), 100 mu f (6.0/3.0 ms), 75 mu f (4.0/2.0) ms, and 50 mu f (3.0/2.0 ms) were 8.5, 10.0, 11.0, 14.0, and 16.5), respectively. These results indicate that a biphasic waveform delivered from a larger capacitance with a proper pulse width could achieve a higher defibrillation efficacy. All DFTs at E50 for all waveforms were compared to their deliverable energies and maximum stored energies. This comparison indicated a narrow DFT safety margin with capacitances below 100 mu f. Therefore, it is concluded that higher energy and higher leading edge voltage are required for a biphasic waveform delivered from a smaller capacitance with a shorter pulse width. Since the current capacitor technology provides a maximum voltage of 750 V using two capacitors in series, with the electrode impedance system used in this study, smaller capacitors appear to have a decreased probability of defibrillation success at a given energy.

  5. 16-Channel biphasic current-mode programmable charge balanced neural stimulation.

    Science.gov (United States)

    Li, Xiaoran; Zhong, Shunan; Morizio, James

    2017-08-14

    Neural stimulation is an important method used to activate or inhibit action potentials of the neuronal anatomical targets found in the brain, central nerve and peripheral nerve. The neural stimulator system produces biphasic pulses that deliver balanced charge into tissue from single or multichannel electrodes. The timing and amplitude of these biphasic pulses are precisely controlled by the neural stimulator software or imbedded algorithms. Amplitude mismatch between the anodic current and cathodic current of the biphasic pulse will cause permanently damage for the neural tissues. The main goal of our circuit and layout design is to implement a 16-channel biphasic current mode programmable neural stimulator with calibration to minimize the current mismatch caused by inherent complementary metal oxide semiconductor (CMOS) manufacturing processes. This paper presents a 16-channel constant current mode neural stimulator chip. Each channel consists of a 7-bit controllable current DAC used as sink and source current driver. To reduce the LSB quantization error and the current mismatch, an automatic calibration circuit and flow diagram is presented in this paper. There are two modes of operation of the stimulator chip-namely, stimulation mode and calibration mode. The chip also includes a digital interface used to control the stimulator parameters and calibration levels specific for each individual channel. This stimulator Application Specific Integrated Circuit (ASIC) is designed and fabricated in a 0.18 μm High-Voltage CMOS technology that allows for ±20 V power supply. The full-scale stimulation current was designed to be at 1 mA per channel. The output current was shown to be constant throughout the timing cycles over a wide range of electrode load impedances. The calibration circuit was also designed to reduce the effect of CMOS process variation of the P-channel metal oxide semiconductor (PMOS) and N-channel metal oxide semiconductor (NMOS) devices that will

  6. Square biphasic pulse deep brain stimulation for essential tremor: The BiP tremor study.

    Science.gov (United States)

    De Jesus, Sol; Almeida, Leonardo; Shahgholi, Leili; Martinez-Ramirez, Daniel; Roper, Jaimie; Hass, Chris J; Akbar, Umer; Wagle Shukla, Aparna; Raike, Robert S; Okun, Michael S

    2018-01-01

    Conventional deep brain stimulation (DBS) utilizes regular, high frequency pulses to treat medication-refractory symptoms in essential tremor (ET). Modifications of DBS pulse shape to achieve improved effectiveness is a promising approach. The current study assessed the safety, tolerability and effectiveness of square biphasic pulse shaping as an alternative to conventional ET DBS. This pilot study compared biphasic pulses (BiP) versus conventional DBS pulses (ClinDBS). Eleven ET subjects with clinically optimized ventralis intermedius nucleus DBS were enrolled. Objective measures were obtained over 3 h while ON BiP stimulation. There was observed benefit in the Fahn-Tolosa Tremor Rating Scale (TRS) for BiP conditions when compared to the DBS off condition and to ClinDBS setting. Total TRS scores during the DBS OFF condition (28.5 IQR = 24.5-35.25) were significantly higher than the other time points. Following active DBS, TRS improved to (20 IQR = 13.8-24.3) at ClinDBS setting and to (16.5 IQR = 12-20.75) at the 3 h period ON BiP stimulation (p = 0.001). Accelerometer recordings revealed improvement in tremor at rest (χ 2  = 16.1, p = 0.006), posture (χ 2  = 15.9, p = 0.007) and with action (χ 2  = 32.1, p=<0.001) when comparing median total scores at ClinDBS and OFF DBS conditions to 3 h ON BiP stimulation. There were no adverse effects and gait was not impacted. BiP was safe, tolerable and effective on the tremor symptoms when tested up to 3 h. This study demonstrated the feasibility of applying a novel DBS waveform in the clinic setting. Larger prospective studies with longer clinical follow-up will be required. Copyright © 2017. Published by Elsevier Ltd.

  7. Current Extensions on PULSE

    Directory of Open Access Journals (Sweden)

    Sanda Dragos

    2010-09-01

    Full Text Available Using a learning management system (LMS is a common practise nowadays. Such instruments are used in educational institutions to enhance and support the teaching act as well as in industry for training purposes. In a computer science department of an university such instrument tends to be a basic requirement. That is because not only it allows a better management of courses and a better communication between students and professors, but can also serve as a perfect instrument for presenting teaching related materials for computer science subjects. During the years I have created and used several such instruments: a System with Interactive ackNowledgement and Evaluation of students work during laboratory sessions (SINE, a Php Utility used in Laboratories for Student Evaluation (PULSE, and PULSE Extended. The aim of this paper is to present the current enhancements of PULSE.

  8. A pilot trial of square biphasic pulse deep brain stimulation for dystonia: The BIP dystonia study.

    Science.gov (United States)

    Almeida, Leonardo; Martinez-Ramirez, Daniel; Ahmed, Bilal; Deeb, Wissam; Jesus, Sol De; Skinner, Jared; Terza, Matthew J; Akbar, Umer; Raike, Robert S; Hass, Chris J; Okun, Michael S

    2017-04-01

    Dystonia often has inconsistent benefits and requires more energy-demanding DBS settings. Studies suggest that squared biphasic pulses could provide significant clinical benefit; however, dystonia patients have not been explored. To assess safety and tolerability of square biphasic DBS in dystonia patients. This study included primary generalized or cervical dystonia patients with bilateral GPi DBS. Square biphasic pulses were implemented and patients were assessed at baseline, immediately postwashout, post-30-minute washout, 1 hour post- and 2 hours postinitiation of investigational settings. Ten participants completed the study. There were no patient-reported or clinician-observed side effects. There was improvement across time on the Toronto Western Spasmodic Torticollis Rating Scale (χ 2  = 10.7; P = 0.031). Similar improvement was detected in objective gait measurements. Square biphasic stimulation appears safe and feasible in dystonia patients with GPi DBS. Further studies are needed to evaluate possible effectiveness particularly in cervical and gait features. © 2016 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  9. Multicompartment retinal ganglion cells response to high frequency bi-phasic pulse train stimulation: Simulation results.

    Science.gov (United States)

    Maturana, Matias I; Grayden, David B; Burkitt, Anthony N; Meffin, Hamish; Kameneva, Tatiana

    2013-01-01

    Retinal ganglion cells (RGCs) are the sole output neurons of the retina that carry information about a visual scene to the brain. By stimulating RGCs with electrical stimulation, it is possible to elicit a sensation of light for people with macular degeneration or retinitis pigmentosa. To investigate the responses of RGCs to high frequency bi-phasic pulse train stimulation, we use previously constrained models of multi-compartment OFF RGCs. The morphologies of mouse RGCs are taken from the Chalupa set of the NeuroMorpho database. The cell models are divided into compartments representing the dendrites, soma and axon that vary between the cells. A total of 132 cells are simulated in the NEURON environment. Results show that the cell morphology plays an important role in the response characteristics of the cell to high frequency bi-phasic pulse train stimulation.

  10. Biphasic pulses enhance bleomycin efficacy in a spontaneous canine genital tumor model of chemoresistance: Sticker sarcoma

    Directory of Open Access Journals (Sweden)

    Citro Gennaro

    2008-11-01

    Full Text Available Abstract Sticker's sarcoma (also known as transmissible venereal tumor is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT, treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy. Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 μs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations.

  11. High current transistor pulse generator

    Science.gov (United States)

    Nesterov, V.; Cassel, R.

    1991-05-01

    A solid state pulse generator capable of delivering high current trapezoidally shaped pulses into an inductive load has been developed at SLAC. Energy stored in the capacitor bank of the pulse generator is switched to the load through a pair of Darlington transistors. A combination of diodes and Darlington transistors is used to obtain trapezoidal or triangular shaped current pulses into an inductive load and to recover the remaining energy in the same capacitor bank without reversing capacitor voltage. The transistors work in the switch mode, and the power losses are low. The rack mounted pulse generators presently used at SLAC contain a 660 microfarad storage capacitor bank and can deliver 400 amps at 800 volts into inductive loads up to 3 mH. The pulse generators are used in several different power systems, including pulse to pulse bipolar power supplies and in application with current pulses distributed into different inductive loads. The current amplitude and discharge time are controlled by the central computer system through a specially developed multichannel controller. Several years of operation with the pulse generators have proven their consistent performance and reliability.

  12. High current transistor pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.; Cassel, R.

    1991-05-01

    A solid state pulse generator capable of delivering high current trapezoidally shaped pulses into an inductive load has been developed at SLAC. Energy stored in the capacitor bank of the pulse generator is switched to the load through a pair of Darlington transistors. A combination of diodes and Darlington transistors is used to obtain trapezoidal or triangular shaped current pulses into an inductive load and to recover the remaining energy in the same capacitor bank without reversing capacitor voltage. The transistors work in the switch mode, and the power losses are low. The rack mounted pulse generators presently used at SLAC contain a 660 microfarad storage capacitor bank and can deliver 400 amps at 800 volts into inductive loads up to 3 mH. The pulse generators are used in several different power systems, including pulse to pulse bipolar power supplies and in application with current pulses distributed into different inductive loads. The current amplitude and discharge time are controlled by the central computer system through a specially developed multichannel controller. Several years of operation with the pulse generators have proven their consistent performance and reliability. 8 figs

  13. Optimized FIR filters for digital pulse compression of biphase codes with low sidelobes

    Science.gov (United States)

    Sanal, M.; Kuloor, R.; Sagayaraj, M. J.

    In miniaturized radars where power, real estate, speed and low cost are tight constraints and Doppler tolerance is not a major concern biphase codes are popular and FIR filter is used for digital pulse compression (DPC) implementation to achieve required range resolution. Disadvantage of low peak to sidelobe ratio (PSR) of biphase codes can be overcome by linear programming for either single stage mismatched filter or two stage approach i.e. matched filter followed by sidelobe suppression filter (SSF) filter. Linear programming (LP) calls for longer filter lengths to obtain desirable PSR. Longer the filter length greater will be the number of multipliers, hence more will be the requirement of logic resources used in the FPGAs and many time becomes design challenge for system on chip (SoC) requirement. This requirement of multipliers can be brought down by clustering the tap weights of the filter by kmeans clustering algorithm at the cost of few dB deterioration in PSR. The cluster centroid as tap weight reduces logic used in FPGA for FIR filters to a great extent by reducing number of weight multipliers. Since k-means clustering is an iterative algorithm, centroid for weights cluster is different in different iterations and causes different clusters. This causes difference in clustering of weights and sometimes even it may happen that lesser number of multiplier and lesser length of filter provide better PSR.

  14. Quantitative pulsed eddy current analysis

    International Nuclear Information System (INIS)

    Morris, R.A.

    1975-01-01

    The potential of pulsed eddy current testing for furnishing more information than conventional single-frequency eddy current methods has been known for some time. However, a fundamental problem has been analyzing the pulse shape with sufficient precision to produce accurate quantitative results. Accordingly, the primary goal of this investigation was to: demonstrate ways of digitizing the short pulses encountered in PEC testing, and to develop empirical analysis techniques that would predict some of the parameters (e.g., depth) of simple types of defect. This report describes a digitizing technique using a computer and either a conventional nuclear ADC or a fast transient analyzer; the computer software used to collect and analyze pulses; and some of the results obtained. (U.S.)

  15. Biphasic electrical currents stimulation promotes both proliferation and differentiation of fetal neural stem cells.

    Directory of Open Access Journals (Sweden)

    Keun-A Chang

    2011-04-01

    Full Text Available The use of non-chemical methods to differentiate stem cells has attracted researchers from multiple disciplines, including the engineering and the biomedical fields. No doubt, growth factor based methods are still the most dominant of achieving some level of proliferation and differentiation control--however, chemical based methods are still limited by the quality, source, and amount of the utilized reagents. Well-defined non-chemical methods to differentiate stem cells allow stem cell scientists to control stem cell biology by precisely administering the pre-defined parameters, whether they are structural cues, substrate stiffness, or in the form of current flow. We have developed a culture system that allows normal stem cell growth and the option of applying continuous and defined levels of electric current to alter the cell biology of growing cells. This biphasic current stimulator chip employing ITO electrodes generates both positive and negative currents in the same culture chamber without affecting surface chemistry. We found that biphasic electrical currents (BECs significantly increased the proliferation of fetal neural stem cells (NSCs. Furthermore, BECs also promoted the differentiation of fetal NSCs into neuronal cells, as assessed using immunocytochemistry. Our results clearly show that BECs promote both the proliferation and neuronal differentiation of fetal NSCs. It may apply to the development of strategies that employ NSCs in the treatment of various neurodegenerative diseases, such as Alzheimer's and Parkinson's diseases.

  16. High current high accuracy IGBT pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.V.; Donaldson, A.R.

    1995-05-01

    A solid state pulse generator capable of delivering high current triangular or trapezoidal pulses into an inductive load has been developed at SLAC. Energy stored in a capacitor bank of the pulse generator is switched to the load through a pair of insulated gate bipolar transistors (IGBT). The circuit can then recover the remaining energy and transfer it back to the capacitor bank without reversing the capacitor voltage. A third IGBT device is employed to control the initial charge to the capacitor bank, a command charging technique, and to compensate for pulse to pulse power losses. The rack mounted pulse generator contains a 525 μF capacitor bank. It can deliver 500 A at 900V into inductive loads up to 3 mH. The current amplitude and discharge time are controlled to 0.02% accuracy by a precision controller through the SLAC central computer system. This pulse generator drives a series pair of extraction dipoles

  17. High current pulsed positron microprobe

    International Nuclear Information System (INIS)

    Howell, R.H.; Stoeffl, W.; Kumar, A.; Sterne, P.A.; Cowan, T.E.; Hartley, J.

    1997-01-01

    We are developing a low energy, microscopically focused, pulsed positron beam for defect analysis by positron lifetime spectroscopy to provide a new defect analysis capability at the 10 10 e + s -l beam at the Lawrence Livermore National Laboratory electron linac. When completed, the pulsed positron microprobe will enable defect specific, 3-dimensional maps of defect concentrations with sub-micron resolution of defect location. By coupling these data with first principles calculations of defect specific positron lifetimes and positron implantation profiles we will both map the identity and concentration of defect distributions

  18. Local eddy current measurements in pulsed fields

    Energy Technology Data Exchange (ETDEWEB)

    Espina-Hernandez, J.H. [SEPI-Electronica, ESIME-IPN, UPALM Edif. ' Z' . Zacatenco, Mexico DF 07738 (Mexico)], E-mail: jhespina@gmail.com; Groessinger, R. [Institute of Solid State Physics, Vienna University of Technology, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Hallen, J.M. [Departamento de Ingenieria Metalurgica, IPN-ESIQIE, UPALM Edif. 7, Zacatenco, Mexico DF 07738 (Mexico)

    2008-07-15

    This work presents new eddy current measurements in pulsed fields. A commercial point pick-up coil is used to detect the induction signal along the radius of Cu and Al samples with cylindrical shape and diameters between 5 and 35 mm. Local eddy current measurements were performed on the surface of conducting materials due to the small dimensions of the coil. A simple electrical circuit, used as a model, is proposed to describe the local eddy current effect in pulsed fields. The proposed model allows to calculate the phase shift angle between the signal proportional to eddy currents and the applied external field in a pulsed field magnetometer.

  19. Chiral separation of α-cyclohexylmandelic acid enantiomers by high-speed counter-current chromatography with biphasic recognition

    Science.gov (United States)

    Tong, Shengqiang

    2010-01-01

    This work concentrates on a novel chiral separation technology named biphasic recognition applied to resolution of α-cyclohexylmandelic acid enantiomers by high-speed counter-current chromatography (HSCCC). The biphasic chiral recognition HSCCC was performed by adding lipophilic (−)-2-ethylhexyl tartrate in the organic stationary phase and hydrophilic hydroxypropyl-β-cyclodextrin in the aqueous mobile phase, which preferentially recognized the (−)-enantiomer and (+)-enantiomer, respectively. The two-phase solvent system composed of n-hexane-methyl tert-butyl ether-water (9:1:10, v/v/v) with the above chiral selectors was selected according to the partition coefficient and separation factor of the target enantiomers. Various parameters involved in the chiral separation were investigated, namely the types of the chiral selector (CS); the concentration of each chiral selector; pH of the mobile phase; and the separation temperature. The mechanism involved in this biphasic recognition chiral separation by HSCCC was discussed. Langmuirian isotherm was employed to estimate the loading limits for each chiral selector. The overall experimental results show that the HSCCC separation of enantiomer based on biphasic recognition is much more efficient than the traditional monophasic recognition chiral separation, since it utilizes the cooperation of both lipophilic and hydrophilic chiral selectors. PMID:20303497

  20. Adjustable direct current and pulsed circuit fault current limiter

    Science.gov (United States)

    Boenig, Heinrich J.; Schillig, Josef B.

    2003-09-23

    A fault current limiting system for direct current circuits and for pulsed power circuit. In the circuits, a current source biases a diode that is in series with the circuits' transmission line. If fault current in a circuit exceeds current from the current source biasing the diode open, the diode will cease conducting and route the fault current through the current source and an inductor. This limits the rate of rise and the peak value of the fault current.

  1. Pulse current enhanced electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian R.; Ottosen, Lisbeth M.; Jensen, Pernille E.

    2012-01-01

    with the pulse frequency. It was found that the transportation of cations through the cation exchange membrane was the rate controlling step both in constant and pulse current experiments, thus responsible for the major energy consumption. Substitution of the cation exchange membrane with filter paper resulted......Energy consumption is an important factor influencing the cost of electrodialytic soil remediation (EDR). It has been indicated that the pulse current (in low frequency range) could decrease the energy consumption during EDR. This work is focused on the comparison of energy saving effect...

  2. Railgun conductor heating from multiple current pulses

    International Nuclear Information System (INIS)

    Kerrisk, J.F.

    1986-01-01

    A numerical technique for solving current- and thermal-diffusion problems in railgun conductors has been used to study joule heating in rails that are subject to multiple current pulses. Copper rails that are 25 mm high by the 12.5 mm wide with a 20-mm-square bore and a current pulse with 1-MA peak current and 1-ms pulse width at half maximum were assumed. This combination of parameters is sufficient to accelerate an 80-g projectile to 2-3 km/s with which current pulse. Three parameters were varied in the analysis: the repetition rate or current pulse frequency (3.3 to 100 Hz), the coolant heat-transfer coefficient (5 x 10 4 and 5 x 10 5 W/m 2 .K), and the coolant channel distribution in the rail. Detailed results are used to illustrate the acceptability or unacceptability of particular combinations of these parameters for operation at steady state. An uncooled rail was not acceptable for steady-state operation. Repetition rates of about 30 Hz were acceptable with the higher coolant heat-transfer coefficient and the best coolant-channel distribution; this included cooling the rail exterior surface

  3. Current pulse shaping of the load current on PTS

    Directory of Open Access Journals (Sweden)

    Minghe Xia

    2016-02-01

    Full Text Available The typical rise time of PTS machine is ∼110 ns with about 10 MA peak current under short pulse mode when all 24 modules discharge simultaneously. By distributing the trigger times of 12 laser beams logically and adjusting the statues of the pulse output switches, longer rise-time pulse can be obtained on the PTS facility. Based on the required pulse shape, whole circuit simulations will be used to calculate the trigger times of each laser triggering gas switch and the status of the pulse output switches. The rise time of the current is determined by the time difference between the first and last trigged laser triggering gas switches. In order to trigger the laser triggering gas switch, sufficient laser power is needed to be sent into the gap of the gas switches. The gas pressure and voltage difference on the two electrodes of the gas switches also affect the triggering of the gas switches, and the voltage added on the gas switch is determined by its transition time. Traditionally the trigger time difference should be less than the transition time of the two neighboring modules. A new simulation model of PTS shows one can break this transition time limits. Series of current pulse shaping experiments have been investigated on the PTS (Primary Test Stand. As results, more than 5 MA peak current were successfully achieved on the load with a rise time of 600 ns. This study and experiments of the pulse shaping on PTS demonstrate the adaptable ability of the PTS for offering different waveform of mega ampere current pulse for different research purpose.

  4. Pulsed current transformer for low inductive loads

    Science.gov (United States)

    Zielinski, Alex; Jamison, Keith; Bennett, John

    1987-10-01

    At the US Army Research, Development and Engineering Command (ARDEC), an effort was undertaken to couple an array of five capacitor banks to a low inductance load. To achieve currents which exceed the limit placed on the capacitor banks, pulse current transformers were used. This power system, termed CAPSTAR, was ultimately used to electromagnetically stress a round bore composite railgun barrel section. A mathematical model has been developed to simulate a capacitor power supply driving a pulse transformer with various secondary loads. The model was first tested by comparison to experimental results using a subscale pulse transformer. The calculated data points were in good agreement with the experiment. Minor adjustments to some circuit parameters to account for the transitory behavior of the circuit are described.

  5. Assessment of the Efficacy of Pulsed Biphasic Defibrillation Shocks for Treatment of Out-of-hospital Cardiac Arrest

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Didon

    2008-10-01

    Full Text Available This study evaluates the efficacy of a Pulsed Biphasic Waveform (PBW for treatment of out-of-hospital cardiac arrest (OHCA patients in ventricular fibrillation (VF. Large database (2001-2006, collected with automated external defibrillators (AED, (FRED®, Schiller Medical SAS, France, is processed.In Study1 we compared the defibrillation efficacy of two energy stacks (90-130-180 J vs. (130-130-180 J in 248 OHCA VF patients. The analysis of the first shock PBW efficacy proves that energies as low as 90 J are able to terminate VF in a large proportion of OHCA patients (77% at 5 s and 69% at 30 s. Although the results show a trend towards the benefit of higher energy PBW with 130 J (86% at 5 s, 73% at 30 s, the difference in shock efficacy does not reach statistical significance. Both PBW energy stacks (90-130-180 J and (130-130-180 J achieve equal success rates of defibrillation. Analysis of the post-shock rhythm after the first shock is also provided.For Study2 of 21 patients with PBW shocks (130-130-180 J, we assessed some attending OHCA circumstances: call-to-shock delay (median 16min, range 11-41 min, phone advices of CPR (67%. About 50% of the patients were admitted alive to hospital, and 19% were discharged from hospital. After the first shock, patients admitted to hospital are more often presenting organized rhythm (OR (27% to 55% than patients not admitted (0% to 10%, with significant difference at 15 s and 30 s. Post-shock VFs appear significantly rare until 15s for patients admitted to hospital (0% to 9% than for patients not admitted to hospital (40% to 50%. Return of OR (ROOR and efficacy to defibrillate VF at 5 s and 15 s with first shock are important markers to predict patient admission to hospital.

  6. Optimizing pulsed current micro plasma arc welding parameters to ...

    African Journals Online (AJOL)

    This paper reveals the influences of pulsed current parameters namely peak current, back current, pulse and pulse width on the ultimate tensile strength of Micro Plasma Arc Welded Inconel 625 sheets. Mathematical model is developed to predict ultimate tensile strength of pulsed current micro plasma arc welded Inconel ...

  7. Pulsed eddy currents: principle and applications

    International Nuclear Information System (INIS)

    Bernard, A.; Coutanceau, N.

    1993-04-01

    Eddy currents are widely used as a non destructive testing technique specially for heat exchanger testing. The specificities of pulsed eddy current testing are analyzed in terms of probe design and signal processing. The specific applications are detailed. They are divided in two parts. First part, deals with the two main applications of the high peak energy supplied to the probe. One concerns the design of focused probes used for the detection of small defects in irradiated fuel rods. The other concerns the saturation of ferromagnetic materials in order to test the full thickness of the exchanger tubes. Second part, deals with applications of the wide and low frequency spectrum generated by the pulse source. It enables the testing of thick materials, and the detection of sub-surface defects. It has been tested on austenitic steel (nuclear pressure vessel nozzle), multilayered structures of aluminium alloys (aeronautics) and sleeved structures (nuclear pressure vessel head penetrations through thermal sleeves)

  8. Electric fields in plasmas under pulsed currents

    International Nuclear Information System (INIS)

    Tsigutkin, K.; Doron, R.; Stambulchik, E.; Bernshtam, V.; Maron, Y.; Fruchtman, A.; Commisso, R. J.

    2007-01-01

    Electric fields in a plasma that conducts a high-current pulse are measured as a function of time and space. The experiment is performed using a coaxial configuration, in which a current rising to 160 kA in 100 ns is conducted through a plasma that prefills the region between two coaxial electrodes. The electric field is determined using laser spectroscopy and line-shape analysis. Plasma doping allows for three-dimensional spatially resolved measurements. The measured peak magnitude and propagation velocity of the electric field is found to match those of the Hall electric field, inferred from the magnetic-field front propagation measured previously

  9. Pulsed high current ion beam processing equipment

    International Nuclear Information System (INIS)

    Korenev, S.A.; Perry, A.

    1995-01-01

    A pulsed high voltage ion source is considered for use in ion beam processing for the surface modification of materials, and deposition of conducting films on different substrates. The source consists of an Arkad'ev-Marx high voltage generator, a vacuum ion diode based on explosive ion emission, and a vacuum chamber as substrate holder. The ion diode allows conducting films to be deposited from metal or allow sources, with ion beam mixing, onto substrates held at a pre-selected temperature. The main variables can be set in the ranges: voltage 100-700 kV, pulse length 0.3 μs, beam current 1-200 A depending on the ion chosen. The applications of this technology are discussed in semiconductor, superconductor and metallizing applications as well as the direction of future development and cost of these devices for commercial application. 14 refs., 6 figs

  10. Development of BMD-1 model standard pulse current generator

    International Nuclear Information System (INIS)

    Lai Bingquan

    1998-12-01

    The BMD-1 Model Standard Pulse Current Generator is a pulse current calibration instrument. It is used to calibrate current probe, amplifier of current probe and other current measurement instruments. The standard pulse current generator uses a perfect current switch to transfer the standard direct current into the standard pulse current. It provides a variable output current ranges from 1 mA to 1 A, current accuracy is +-(0.25% + 2μA). The standard pulse generator provides three work modes of output current: DC, signal pulse and variable frequencies from 10 Hz to 1 MHz, and provides a variable pulse current widths from 0.5 to 50 μs

  11. Post stimulus effects of high frequency biphasic electrical current on a fibre's conductibility in isolated frog nerves

    Science.gov (United States)

    Liu, Hailong; Zhu, Linlin; Sheng, Shulei; Sun, Lifei; Zhou, Hongmin; Tang, Hong; Qiu, Tianshuang

    2013-06-01

    Objective. High frequency biphasic (HFB) electrical currents are widely used in nerve blocking studies. Their safety margins largely remain unknown and need to be investigated. Approach. This study, exploring the post stimulus effects of HFB electrical currents on a nerve's conductibility, was performed on bullfrog sciatic nerves. Both compound action potentials (CAPs) and differential CAPs (DCAPs, i.e. control CAPs subtracted by CAPs following HFB currents) were obtained, and N1 and N2 components, which were the first and second upward components of DCAPs, were used for analyses of the effects introduced by HFB electrical stimulation. Main results. First, HFB currents of 10 kHz at a completely blocking threshold were applied for 5 s. The maximum amplitudes and conducting velocities of the CAPs were significantly (P time, regarded as the recovery of the nerve's conductibility, exhibited two distinct phases: a fast one lasting several seconds and a slow one lasting longer than 5 min. Further tests showed a linear relationship between the HFB stimulation durations and recovering periods of N1 amplitudes. Supra-threshold blocking did not cause higher N1 amplitudes. Significance. This study indicates that HFB electrical currents lead to long lasting post stimulus reduction of a nerve's conductibility, which might relate to potential nerve injuries. A possible mechanism, focusing on changes in intracellular and periaxonal ionic concentrations, was proposed to underlie the reduction of the nerve's conductibility and potential nerve injuries. Greater caution and stimulation protocols with greater safety margins should be explored when utilizing HFB electrical current to block nerve conductions.

  12. Current pulse generator of an induction accelerator electromagnet

    International Nuclear Information System (INIS)

    Baginskij, B.A.; Makarevich, V.N.; Shtejn, M.M.

    1987-01-01

    Thyristor generator forming in betatron electromagnet coil sinusoidal and quasisinusoidal current unipolar pulses, the field being deforced at the beginning of acceleration cycle, and with the pulse flat top in the cycle end, is described. The current amplitude is controlled by pulse-phase method. The current pulse time shift permitted to decrease the loss rate in the accumulating capacitor. The generator is used in systems with 1-10 ms pulse duration, electromagnet magnetic field maximal energy - 45-450 J, the voltage amplitude in the coil 960-1500 V and amplitude of the current passing the coil 100-500 A, the repetition frequency being 50-200 Hz. In particular, the generator is used to supply betatrons designed for defectoscopy in nonstationary conditions, the accelerated electron energy being 4, 6, 8 and 15 MeV

  13. Pulsed Current Static Electrical Contact Experiment

    National Research Council Canada - National Science Library

    Jones, Harry N; Neri, Jesse M; Boyer, Craig N; Cooper, Khershed P; Meger, Robert A

    2006-01-01

    Railguns involve both static and sliding electrical contacts, which must transmit the large transient electrical currents necessary to impart high forces onto a projectile for acceleration to hypervelocity...

  14. Electrodialytic soil remediation enhanced by low frequency pulse current

    DEFF Research Database (Denmark)

    Sun, Tian R.; Ottosen, Lisbeth M.; Mortensen, John

    2013-01-01

    The effect of low frequency pulse current on decreasing the polarization and energy consumption during the process of electrodialytic soil remediation was investigated in the present work. The results indicated that the transportation of cations through the cation exchange membrane was the rate...... controlling step both in constant and pulse current experiments, thus responsible for the major energy consumption. After 180. h, a decrease in both the initial ohmic resistance in each pulse cycle and the resistance caused by concentration polarization of the anion exchange membrane were seen in the pulse...... current experiment compared to the constant current experiment. At the cation exchange membrane, only the resistance caused by concentration polarization decreased. In the soil compartment, an average of +60. mV overpotential caused by the polarization of the electric double layer of the clay particles...

  15. Modeling of Pulsed Direct-Current Glow Discharge

    International Nuclear Information System (INIS)

    Du Mu; Zheng Yaru; Fan Yujia; Zhang Nan; Liu Chengsen; Wang Dezhen

    2010-01-01

    A self-consistent model was adopted to study the time evolution of low-voltage pulsed DC glow discharge. The distributions of electric field, ion density and electron density in nitrogen were investigated in our simulation, and the temporal shape of the discharge current was also obtained. Our results show that the dynamic behaviors of the discharge depends strongly on the applied pulse voltage, and the use of higher pulse voltages results in a significantly increase of discharge current and a decrease of discharge delay time. The current-voltage characteristic calculated by adjusting secondary electron emission coefficient for different applied pulse voltage under the gas pressure of 1 Torr is found in a reasonable agreement with the experimental results.

  16. Research of long pulse high current diode radial insulation

    International Nuclear Information System (INIS)

    Tan Jie; Chang Anbi; Hu Kesong; Liu Qingxiang; Ma Qiaosheng; Liu Zhong

    2002-01-01

    A radial insulation structure which is used in long pulse high current diode is introduced. The theory of vacuum flashover and the idea of design are briefly introduced. In the research, cone-shaped insulator was used. The geometry structure parameters were optimized by simulating the static electrical field distribution. Experiment was done on a pulse power source with 200 ns pulse width. The maximum voltage 750 kV was obtained, and the average stand-off electrical field of insulator is about 50 kV/cm

  17. Low-Frequency Pulsed Current Versus Kilohertz-Frequency Alternating Current: A Scoping Literature Review.

    Science.gov (United States)

    Vaz, Marco Aurélio; Frasson, Viviane Bortoluzzi

    2017-12-14

    To compare the effectiveness of low-frequency pulsed current versus kilohertz-frequency alternating current in terms of evoked force, discomfort level, current intensity, and muscle fatigability; to discuss the physiological mechanisms of each neuromuscular electrical stimulation type; and to determine if kilohertz-frequency alternating current is better than low-frequency pulsed current for clinical treatment. Articles were obtained from PubMed, Scopus, Cochrane Central Register of Controlled Trials, CINAHL, MEDLINE, and SPORTSDiscus databases using the terms Russian current or kilohertz current or alternating current or pulsed current or Aussie current and torque or discomfort or fatigue or current intensity, and through citation tracking up to July 2017. Two independent reviewers selected studies comparing the use of the 2 neuromuscular electrical stimulation currents. Studies describing maximal current intensity tolerated and the main effects of the 2 different current types on discomfort, muscle force, and fatigability were independently reviewed. Data were systematized according to (1) methodology; (2) electrical current characteristics; and (3) outcomes on discomfort level, evoked force, current intensity, and muscle fatigability. The search revealed 15 articles comparing the 2 current types. Kilohertz-frequency alternated current generated equal or less force, similar discomfort, similar current intensity for maximal tolerated neuromuscular electrical stimulation, and more fatigue compared with low-frequency pulsed current. Similar submaximal levels of evoked force revealed higher discomfort and current intensity for kilohertz-frequency alternated current compared with low-frequency pulsed current. Available evidence does not support the idea that kilohertz-frequency alternated current is better than low-frequency pulsed current for strength training and rehabilitation. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier

  18. Pulse current gas metal arc welding characteristics, control and applications

    CERN Document Server

    Ghosh, Prakriti Kumar

    2017-01-01

    This monograph is a first-of-its-kind compilation on high deposition pulse current GMAW process. The nine chapters of this monograph may serve as a comprehensive knowledge tool to use advanced welding engineering in prospective applications. The contents of this book will prove useful to the shop floor welding engineer in handling this otherwise critical welding process with confidence. It will also serve to inspire researchers to think critically on more versatile applications of the unique nature of pulse current in GMAW process to develop cutting edge welding technology.

  19. New Pulsed Power Technology for High Current Accelerators

    International Nuclear Information System (INIS)

    Caporaso, G J

    2002-01-01

    Recent advances in solid-state modulators now permit the design of a new class of high current accelerators. These new accelerators will be able to operate in burst mode at frequencies of several MHz with unprecedented flexibility and precision in pulse format. These new modulators can drive accelerators to high average powers that far exceed those of any other technology and can be used to enable precision beam manipulations. New insulator technology combined with novel pulse forming lines and switching may enable the construction of a new type of high gradient, high current accelerator. Recent developments in these areas will be reviewed

  20. Pulsed current signals in capacitor type particle detectors

    International Nuclear Information System (INIS)

    Gaubas, E; Ceponis, T; Pavlov, J

    2015-01-01

    The problem of pulsed current signals in capacitor type sensors, due to drifting surface charge domain is considered for the analysis of the operational characteristics in photo- and particle-detectors. In this article, the models of the formation of the pulsed currents have been analyzed in vacuum and dielectric filled capacitor-like detectors. Injected charge drift regimes such as Shockley-Ramo's-type (large charge drift) and free flight within Coulomb's force field (small charge drift) are discussed. It has been shown that solutions of the injected charge drift in the vacuum gap capacitor can be employed to emulate charge drift over free path in dynamic solution of the problem with scattering. Pulsed current signals and charge drift in the detectors of the capacitor filled with dielectric type have been analyzed, where the bipolar charge injection and various drift regimes appear. The bipolar carrier drift transformation to a monopolar one is considered, after either electrons or holes, injected within the material, reach the external electrode. The impact of the dynamic capacitance and load resistance in the formation of drift current transients is highlighted. It has been illustrated that the synchronous action of carrier drift, trapping, generation and diffusion can lead to a vast variety of possible current pulse waveforms

  1. High-current pulses from inductive energy stores

    Science.gov (United States)

    Wipf, S. L.

    1981-11-01

    Superconducting inductive energy stores can be used for high power pulse supplies if a suitable current multiplication scheme is used. The concept of an inductive Marx generator is superior to a transformer. A third scheme, a variable flux linkage device, is suggested; in multiplying current it also compresses energy. Its function is in many ways analogous to that of a horsewhip. Superconductor limits indicate that peak power levels of TW can be reached for stored energies above 1 MJ.

  2. Electronic constant current and current pulse signal generator for nuclear instrumentation testing

    Science.gov (United States)

    Brown, R.A.

    1994-04-19

    Circuitry is described for testing the ability of an intermediate range nuclear instrument to detect and measure a constant current and a periodic current pulse. The invention simulates the resistance and capacitance of the signal connection of a nuclear instrument ion chamber detector and interconnecting cable. An LED flasher/oscillator illuminates an LED at a periodic rate established by a timing capacitor and circuitry internal to the flasher/oscillator. When the LED is on, a periodic current pulse is applied to the instrument. When the LED is off, a constant current is applied. An inductor opposes battery current flow when the LED is on. 1 figures.

  3. Phenomenological Model of Current Sheet Canting in Pulsed Electromagnetic Accelerators

    Science.gov (United States)

    Markusic, Thomas; Choueiri, E. Y.

    2003-01-01

    The phenomenon of current sheet canting in pulsed electromagnetic accelerators is the departure of the plasma sheet (that carries the current) from a plane that is perpendicular to the electrodes to one that is skewed, or tipped. Review of pulsed electromagnetic accelerator literature reveals that current sheet canting is a ubiquitous phenomenon - occurring in all of the standard accelerator geometries. Developing an understanding of current sheet canting is important because it can detract from the propellant sweeping capabilities of current sheets and, hence, negatively impact the overall efficiency of pulsed electromagnetic accelerators. In the present study, it is postulated that depletion of plasma near the anode, which results from axial density gradient induced diamagnetic drift, occurs during the early stages of the discharge, creating a density gradient normal to the anode, with a characteristic length on the order of the ion skin depth. Rapid penetration of the magnetic field through this region ensues, due to the Hall effect, leading to a canted current front ahead of the initial current conduction channel. In this model, once the current sheet reaches appreciable speeds, entrainment of stationary propellant replenishes plasma in the anode region, inhibiting further Hall-convective transport of the magnetic field; however, the previously established tilted current sheet remains at a fairly constant canting angle for the remainder of the discharge cycle, exerting a transverse J x B force which drives plasma toward the cathode and accumulates it there. This proposed sequence of events has been incorporated into a phenomenological model. The model predicts that canting can be reduced by using low atomic mass propellants with high propellant loading number density; the model results are shown to give qualitative agreement with experimentally measured canting angle mass dependence trends.

  4. Control of Domain Wall Polarity by Current Pulses

    Science.gov (United States)

    Vanhaverbeke, A.; Bischof, A.; Allenspach, R.

    2008-09-01

    Direct observation of current-induced propagation of purely transverse magnetic domain walls with spin-polarized scanning electron microscopy is reported in Fe30Ni70 nanowires. After propagation, the domain walls keep their transverse nature but switch polarity in some cases. For uniform Ni70Fe30 wires, the effect is random and illustrates domain-wall propagation above the Walker threshold. In the case of Ni70Fe30/Fe wires, the transverse magnetization component in the wall is entirely determined by the polarity of the current pulse, an effect that is not reconciled by present theories even when taking into account the nonuniform Oersted field generated by the current.

  5. Computation of current pulsed sources with inductive energy storages

    OpenAIRE

    Nosov, G. V.

    2007-01-01

    Formulas for computation of efficiency and parameters of current pulsed sources at charging and discharging of the inductive energy storage on active loading have been obtained. For charging the inductive storage the electric and capacitor batteries, unipolar and synchronous electric generators with the rectifier, equivalent circuit of which can be presented by consecutive connection of equivalent capacity, inductance and resistance are considered. Formulas, at which high efficiency of charge...

  6. Very Fast Current Diagnostic for Linear Pulsed Beams

    Science.gov (United States)

    Nassisi, Vincenzo; Delle Side, Domenico; Turco, Vito

    2018-01-01

    Fast current pulses manage lasers and particle accelerators and require sophisticate systems to be detected. At today Rogowski coils are well known. They are designed and built with a toroidal structure. In recently application, flat transmission lines are imploded and for this reason we develop a linear Rogowski coil to detect current pulses inside flat conductors. To get deep information from the system, it was approached by means of the theory of the transmission lines. The coil we build presents a resistance but it doesn't influence the rise time of the response, instead the integrating time. We also studied the influence of the magnetic properties of coil support. The new device was able to record pulses of more hundred nanoseconds depending on the inductance, load impedance and resistance of the coil. Furthermore, its response was characterized by a sub-nanosecond rise time ( 100 ps), The attenuation coefficient depends mainly on the turn number of the coil, while the quality of the response depends both on the manufacture quality of the coil and on the magnetic core characteristics. In biophysical applications often, a double line is employed in order to have a sample as control and a sample stressed by a light source. So, in this case we build two equal plane lines by 100 Ω characteristic resistance connected in parallel. We diagnosed the current present in a line. The attenuation factor resulted to be 11,5 A/V.

  7. Very Fast Current Diagnostic for Linear Pulsed Beams

    Directory of Open Access Journals (Sweden)

    Nassisi Vincenzo

    2018-01-01

    Full Text Available Fast current pulses manage lasers and particle accelerators and require sophisticate systems to be detected. At today Rogowski coils are well known. They are designed and built with a toroidal structure. In recently application, flat transmission lines are imploded and for this reason we develop a linear Rogowski coil to detect current pulses inside flat conductors. To get deep information from the system, it was approached by means of the theory of the transmission lines. The coil we build presents a resistance but it doesn’t influence the rise time of the response, instead the integrating time. We also studied the influence of the magnetic properties of coil support. The new device was able to record pulses of more hundred nanoseconds depending on the inductance, load impedance and resistance of the coil. Furthermore, its response was characterized by a sub-nanosecond rise time (~100 ps, The attenuation coefficient depends mainly on the turn number of the coil, while the quality of the response depends both on the manufacture quality of the coil and on the magnetic core characteristics. In biophysical applications often, a double line is employed in order to have a sample as control and a sample stressed by a light source. So, in this case we build two equal plane lines by 100 Ω characteristic resistance connected in parallel. We diagnosed the current present in a line. The attenuation factor resulted to be 11,5 A/V.

  8. Transient response of superconducting indium microbridges to supercritical current pulses

    International Nuclear Information System (INIS)

    Frank, D.J.; Tinkham, M.; Davidson, A.; Faris, S.M.

    1983-01-01

    Superconducting sampling circuits have been used to investigate the transient response of long indium microbridges to current pulses in excess of their critical currents. For the first time, the rising-edge kinetic inductance spike and the nonzero minimum voltage have been observed, as well as the delay time until the normal state appears. These results are in reasonable agreement with a detailed theoretical model of the experiment and yield an estimate of 140 ps for tau/sub E/, the inelastic scattering time, in indium

  9. High current precision long pulse electron beam position monitor

    CERN Document Server

    Nelson, S D; Fessenden, T J; Holmes, C

    2000-01-01

    Precision high current long pulse electron beam position monitoring has typically experienced problems with high Q sensors, sensors damped to the point of lack of precision, or sensors that interact substantially with any beam halo thus obscuring the desired signal. As part of the effort to develop a multi-axis electron beam transport system using transverse electromagnetic stripline kicker technology, it is necessary to precisely determine the position and extent of long high energy beams for accurate beam position control (6 - 40 MeV, 1 - 4 kA, 2 μs beam pulse, sub millimeter beam position accuracy.) The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (< 20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt position measurements.

  10. Investigation on a new inducer of pulsed eddy current thermography

    Directory of Open Access Journals (Sweden)

    Min He

    2016-09-01

    Full Text Available In this paper, a new inducer of pulsed eddy current thermography (PECT is presented. The use of the inducer can help avoid the problem of blocking the infrared (IR camera’s view in eddy current thermography technique. The inducer can also provide even heating of the test specimen. This paper is concerned with the temperature distribution law around the crack on a specimen when utilizing the new inducer. Firstly, relative mathematical models are provided. In the following section, eddy current distribution and temperature distribution around the crack are studied using the numerical simulation method. The best separation distance between the inducer and the specimen is also determined. Then, results of temperature distribution around the crack stimulated by the inducer are gained by experiments. Effect of current value on temperature rise is studied as well in the experiments. Based on temperature data, temperature features of the crack are discussed.

  11. A ns-pulsed high-current electron beam source

    International Nuclear Information System (INIS)

    Guan, Gexin; Li, Youzhi; Pan, Yuli

    1988-01-01

    The behaviour of a pulse electron beam source which is composed of a gun and pulse system depends on not only the time characteristics of the gun and the pulser, but also their combination. This point become apparent if effects of the electron tansit-time between electrodes are studied. A ferrite transmission line (FTL) pulser is used as a grid driver in this source. It has advantages of providing fast risetime, large peak power output and good loading characteristics. It is these advantages of the pulser that compensates the absence of some technological conditions of manufacturing gun and makes the source better. Our testing showed that the cooperation of both the gun and the pulser produced peak currents in the range of 1 to 9 amps with widths of 2 to 2.5 ns (FWHM) at cathode-to-anode potential of 60 to 82 kv, while the grid drives are about in the range of 1 to 3 kv. In addition, the results of the testing instructed that effects of electron transit-time cannot be ignored when the pulses with widths of several nanoseconds are used as a grid drive. Based on the results, electron transit-time effects on the design of the gun and the beam performances are briefly descussed in this paper. (author)

  12. High current pulsed linear ion accelerators for inertial fusion applications

    International Nuclear Information System (INIS)

    Humphries, S. Jr.; Yonas, G.; Poukey, J.W.

    1978-01-01

    Pulsed ion beams have a number of advantages for use as inertial fusion drivers. Among these are classical interaction with targets and good efficiency of production. As has been pointed out by members of the accelerator community, multistage accelerators are attractive in this context because of lower current requirements, low power flow per energy conversion stage and low beam divergence at higher ion energies. On the other hand, current transport limits in conventional accelerators constrain them to the use of heavy ions at energies much higher than those needed to meet the divergence requirements, resulting in large, costly systems. We have studied methods of neutralizing ion beams with electrons within the accelerator volume to achieve higher currents. The aim is to arrive at an inexpensive accelerator that can advantageously use existing pulsed voltage technology while being conservative enough to achieve a high repetition rate. Typical output parameters for reactor applications would be an 0 + beam of 30 kA at 300 MeV. We will describe reactor scaling studies and the physics of neutralized linear accelerators using magnetic fields to control the electron dynamics. Recent results are discussed from PULSELAC, a five stage multikiloampere device being tested at Sandia Laboratories

  13. Research on High Current Pulse Discharges at IPP ASci CR

    Czech Academy of Sciences Publication Activity Database

    Koláček, Karel; Schmidt, Jiří; Prukner, Václav; Štraus, Jaroslav; Frolov, Oleksandr; Martínková, M.

    2006-01-01

    Roč. 56, suppl. B (2006), s. 259-266 ISSN 0011-4626. [Symposium on Plasma Physics and Technology/22nd./. Praha, 26.6.2006-29.6.2006] R&D Projects: GA ČR GA202/06/1324; GA MŠk 1P04LA235 Institutional research plan: CEZ:AV0Z20430508 Keywords : Pulsed high current capillary discharge * amplified spontaneous emission * soft X-ray laser Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.568, year: 2006

  14. Interfacing transformer for a pulsed load current exceeding 1 MA

    CERN Document Server

    Cliffe, R J; Brown, J

    2003-01-01

    In much pulsed power experimentation a capacitor bank is discharged into an inductive load, but although sufficient energy may be available in the capacitors their voltage rating may considerably exceed that necessary for the load and the current delivered during the experiment may accordingly be too low. This paper describes a novel design of air-cored transformer that has been used as an interfacing or matching device in such a situation, where peak load currents between 1 and 2 MA were required. Design considerations led to the use of an air-cored autotransformer connection wound with copper sheet conductors. Although thick wide conductors and clamping are needed to prevent deformation due to high magnetic pressure, the transformer is nevertheless relatively simple, easy to make, lightweight and inexpensive. This paper describes the design and the winding arrangement of the transformer that was constructed, and presents typical experimental results.

  15. Electrical and hydrodynamic characterization of a high current pulsed arc

    Science.gov (United States)

    Sousa Martins, R.; Chemartin, L.; Zaepffel, C.; Lalande, Ph; Soufiani, A.

    2016-05-01

    High current pulsed arcs are of significant industrial interest and, aiming to reduce time and cost, there is progressively more and more need for computation tools that describe and predict the behaviour of these arcs. These simulation codes need inputs and validations by experimental databases, but accurate data is missing for this category of electric discharges. The principal lack of understanding is with respect to the transient phase of the current, which can reach thousands of amperes in a few microseconds. In this paper, we present the work realized on an experimental setup that simulates in the laboratory an arc column subjected to five levels of high pulsed current, ranging from 10 kA to 100 kA, with the last one corresponding to the standard lightning current waveform used in aircraft certification processes. This device was instrumented by high speed video cameras to assess the characteristic sizes of the arc channel and to characterize the shock wave generated by the arc expansion. The arc channel radius was measured over time during the axisymmetric phase and reached 3.2 cm. The position and velocity of the shock wave was determined during the first 140 μs. The background-oriented schlieren method was used to study the shock wave and a model for the light deflection inside the shock wave was developed. The mass density profile of the shock wave was estimated and showed good agreement with Rankine-Hugoniot relations at the wave front. Electrical measurements were also used to estimate the time-dependent resistance and conductivity of the arc for times lasting up to 50 μs.

  16. Pulsed negative hydrogen source for currents up to one ampere

    International Nuclear Information System (INIS)

    Prelec, K.; Sluyters, T.

    1975-01-01

    During the 2nd Symposium on Ion Sources and Formation of Ion Beams, the development of a Mk II pulsed double slit magnetron source for the production of negative hydrogen ions was discussed. The source was capable of yielding beam currents up to 125 milliamperes, corresponding to current densities of 1.25 A/cm 2 . In order to increase negative hydrogen beam intensities by an order of magnitude (this would be quite useful for initial high energy neutral injector systems on Tokamaks), a larger, Mk III magnetron has been constructed, with the number of slits increased up to six. The idea was to utilize in a more efficient way the plasma width. In addition, such a source geometry will be more adaptable for beam formation and acceleration than single slit structures. With three extraction slits, a negative hydrogen yield of 300 mA was obtained with current densities of 1.2 A/cm 2 ; preliminary results with six extraction slits showed beam currents in excess of half an ampere with averaged current densities in excess of 0.75 A/cm 2 . (U.S.)

  17. Comparison between short train, monophasic and biphasic repetitive transcranial magnetic stimulation (rTMS) of the human motor cortex.

    Science.gov (United States)

    Arai, Noritoshi; Okabe, Shingo; Furubayashi, Toshiaki; Terao, Yasuo; Yuasa, Kaoru; Ugawa, Yoshikazu

    2005-03-01

    longer when the same intensity of stimulation (the same amount of current is stored by the stimulator) is used. This means that when using rTMS as a therapeutic tool or in research fields, the difference in waveforms of magnetic pulses (monophasic or biphasic) may affect the results.

  18. Generation and measurement of ultrashort current pulses with Josephson devices

    International Nuclear Information System (INIS)

    Faris, S.M.

    1980-01-01

    Experimental demonstration of an ultrashort-pulse generator and a novel sampling technique to measure its pulse shape is reported. The pulse generator, which uses Josephson interferometers, is designed to be dc powered and self-resetting. Its pulses are measured to be 26 ps in duration at a simulated maximum frequency of 2.5 GHz. The sampling technique is useful for measuring general fast waveforms with unprecented sensitivity and resolution extendable to subpicosecond time scale

  19. A novel simulation method for positive corona current pulses

    International Nuclear Information System (INIS)

    Liu Yang; Cui Xiang; Lu Tie-Bing; Li Xue-Bao; Wang Zhen-Guo; Xiang Yu; Wang Xiao-Bo

    2015-01-01

    A novel two-dimensional (2D) simulation method of positive corona current pulses is proposed. A control-volume-based finite element method (CV-FEM) is used to solve continuity equations, and the Galerkin finite element method (FEM) is used to solve Poisson’s equation. In the proposed method, photoionization is considered by adopting an exact Helmholtz photoionization model. Furthermore, fully implicit discretization and variable time step are used to ensure the time-efficiency of the present method. Finally, the method is applied to a positive rod-plane corona problem. The numerical results are in agreement with the experimental results, and the validity of the proposed method is verified. (paper)

  20. Development of high current beam ns pulsed system

    CERN Document Server

    Shen Guan Ren; Gao Fu; Guan Xia Ling; LiuNaiYi

    2001-01-01

    The development of high current beam ns pulsed system of CPNG and its characteristic, main technological performance and application are introduced. Firstly, important parameters of the system are calculated using theoretical model, the design requirements of some important parts are understood. Some mistakes in physics conception are corrected. Second, the chopper is designed for parallel plate deflector, chopping aperture and sine wave voltage sweeping device. It is emphasized that the conception of parallel plate load impedance is the capacitance load, but not the 50 ohm load impedance. The dynamic capacitance value has been measured. The output emphasizes the output voltage amplitude, but not the output power for sweeping device. The display system of output sweeping voltage was set up and it is sure that the maximum output voltage(V-V) is >=4000 V. The klystron buncher are re-designed. It is emphasized to overcome difficulty of support high voltage electrode in the klystron and insulator of input sine wa...

  1. Ultra fast shutter driven by pulsed high current

    International Nuclear Information System (INIS)

    Zeng Jiangtao; Sun Fengju; Qiu Aici; Yin Jiahui; Guo Jianming; Chen Yulan

    2005-01-01

    Radiation simulation utilizing plasma radiation sources (PRS) generates a large number of undesirable debris, which may damage the expensive diagnosing detectors. An ultra fast shutter (UFS) driven by pulsed high current can erect a physical barrier to the slowly moving debris after allowing the passage of X-ray photons. The UFS consists of a pair of thin metal foils twisting the parallel axes in a Nylon cassette, compressed with an outer magnetic field, generated from a fast capacitor bank, discharging into a single turn loop. A typical capacitor bank is of 7.5 μF charging voltages varying from 30 kV to 45 kV, with corresponding currents of approximately 90 kA to 140 kA and discharging current periods of approximately 13.1 μs. A shutter closing time as fast as 38 microseconds has been obtained with an aluminium foil thickness of 100 micrometers and a cross-sectional area of 15 mm by 20 mm. The design, construction and the expressions of the valve-closing time of the UFS are presented along with the measured results of valve-closing velocities. (authors)

  2. Multiply charged metal ions in high current pulsed vacuum arcs

    Science.gov (United States)

    Yushkov, G. Yu.; Nikolaev, A. G.; Frolova, V. P.; Oks, E. M.; Rousskikh, A. G.; Zhigalin, A. S.

    2017-12-01

    We show that vacuum arc plasma discharges with a current of several kiloamperes and duration of a few microseconds can generate multiply charged metal ions with charge states greater than 10+. The physical mechanism behind this is discussed, suggesting an optimum arc current for higher charge states depending on the pulse duration and cathode material. Measurements of ion mass-to-charge ratio and images taken with nanosecond resolution suggest that, higher charge state ions are produced at characteristic distances of ˜10 mm from the cathode as the arc current peaks, and the process responsible for their generation is additional ionization as the discharge is pinched by its self-magnetic field. The maximum and mean ion charge states reveal a considerable increase for the all cathode materials studied: magnesium, aluminum, zirconium, tin, tantalum, gold, lead, and bismuth. For bismuth ions, the maximum charge state reaches a record-breaking value of 17+ and the mean of the charge state distribution is 12.6+. The results obtained are of interest for vacuum arc discharge physics and for ion beam technologies.

  3. Pulse current as a current source with charge-discharge capacitor method for making magnet

    International Nuclear Information System (INIS)

    Handoko, Djati; Farhad, Hasan; Kurniawan, Budhy; Manaf, Azwar

    2002-01-01

    Have been made and analyzed a high current source instrument with charge-discharge capacitor method. A 0.25 kA pulse current have been produce by this instrument. The instrument has 2 capacitors in parallel configuration with 3300 μF/350 V capacitance. Charge and discharge is controlled by closing/opening SCR and adjustable with timer. Analyze has been done for change of voltage in capacitor comparing with time to reach that. The result showed that both of them have linear relationship. The instrument has been done for making magnet based on Nd-Fe-B and SmCo materials and produced better than electromagnet method

  4. The Underlying Mechanism of Preventing Facial Nerve Stimulation by Triphasic Pulse Stimulation in Cochlear Implant Users Assessed With Objective Measure.

    Science.gov (United States)

    Bahmer, Andreas; Baumann, Uwe

    2016-10-01

    Triphasic pulse stimulation prevents from facial nerve stimulation (FNS) because of a different electromyographic input-output function compared with biphasic pulse stimulation. FNS is sometimes observed in cochlear implant users as an unwanted side effect of electrical stimulation of the auditory nerve. The common stimulation applied in current cochlear implant consists of biphasic pulse patterns. Two common clinical remedies to prevent unpleasant FNS caused by activation of certain electrodes are to expand their pulse phase duration or simply deactivate them. Unfortunately, in some patients these methods do not provide sufficient FNS prevention. In these patients triphasic pulse can prevent from FNS. The underlying mechanism is yet unclear. Electromyographic (EMG) recordings of muscles innervated by the facial nerve (musculi orbicularis ori and oculi) were applied to quantitatively assess the effects on FNS. Triphasic and biphasic fitting maps were compared in four subjects with severe FNS. Based on the recordings, a model is presented which intends to explain the beneficial effects of triphasic pulse application. Triphasic stimulation provided by fitting of an OPUS 2 speech processor device. For three patients, EMG was successfully recorded depending on stimulation level up to uncomfortable and intolerable FNS stimulation as upper boarder. The obtained EMG recordings demonstrated high individual variability. However, a difference between the input-output function for biphasic and triphasic pulse stimulation was visually observable. Compared with standard biphasic stimulation, triphasic pulses require higher stimulation levels to elicit an equal amount of FNS, as reflected by EMG amplitudes. In addition, we assume a steeper slope of the input-output function for biphasic pulse stimulation compared with triphasic pulse stimulation. Triphasic pulse stimulation prevents from FNS because of a smaller gradient of EMG input-output function compared with biphasic pulse

  5. Development of optoelectronic-based pulsed current sensor to ...

    Indian Academy of Sciences (India)

    Anil S Nayak

    2017-08-03

    Aug 3, 2017 ... Copper vapour laser (CVL) is a pulsed electric discharge pumped laser. The electrical excitation of the CVL takes place at a pulsed voltage of 10–15 kV at ... drive the optical transmitter on considering proper polarity of the signal. When the voltage developed across R1 reaches to the on-state voltage of the ...

  6. Pulsed Eddy Current Sensing for Critical Pipe Condition Assessment.

    Science.gov (United States)

    Ulapane, Nalika; Alempijevic, Alen; Vidal Calleja, Teresa; Valls Miro, Jaime

    2017-09-26

    Pulsed Eddy Current (PEC) sensing is used for Non-Destructive Evaluation (NDE) of the structural integrity of metallic structures in the aircraft, railway, oil and gas sectors. Urban water utilities also have extensive large ferromagnetic structures in the form of critical pressure pipe systems made of grey cast iron, ductile cast iron and mild steel. The associated material properties render NDE of these pipes by means of electromagnetic sensing a necessity. In recent years PEC sensing has established itself as a state-of-the-art NDE technique in the critical water pipe sector. This paper presents advancements to PEC inspection in view of the specific information demanded from water utilities along with the challenges encountered in this sector. Operating principles of the sensor architecture suitable for application on critical pipes are presented with the associated sensor design and calibration strategy. A Gaussian process-based approach is applied to model a functional relationship between a PEC signal feature and critical pipe wall thickness. A case study demonstrates the sensor's behaviour on a grey cast iron pipe and discusses the implications of the observed results and challenges relating to this application.

  7. A high current, short pulse electron source for wakefield accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Ching-Hung.

    1992-01-01

    Design studies for the generation of a high current, short pulse electron source for the Argonne Wakefield Accelerator are presented. An L-band laser photocathode rf gun cavity is designed using the computer code URMEL to maximize the electric field on the cathode surface for fixed frequency and rf input power. A new technique using a curved incoming laser wavefront to minimize the space charge effect near the photocathode is studied. A preaccelerator with large iris to minimize wakefield effects is used to boost the drive beam to a useful energy of around 20 MeV for wakefield acceleration experiments. Focusing in the photocathode gun and the preaccelerator is accomplished with solenoids. Beam dynamics simulations throughout the preaccelerator are performed using particle simulation codes TBCI-SF and PARMELA. An example providing a useful set of operation parameters for the Argonne Wakefield Accelerator is given. The effects of the sagitta of the curved beam and laser amplitude and timing jitter effects are discussed. Measurement results of low rf power level bench tests and a high power test for the gun cavity are presented and discussed.

  8. A high current, short pulse electron source for wakefield accelerators

    International Nuclear Information System (INIS)

    Ho, Ching-Hung.

    1992-01-01

    Design studies for the generation of a high current, short pulse electron source for the Argonne Wakefield Accelerator are presented. An L-band laser photocathode rf gun cavity is designed using the computer code URMEL to maximize the electric field on the cathode surface for fixed frequency and rf input power. A new technique using a curved incoming laser wavefront to minimize the space charge effect near the photocathode is studied. A preaccelerator with large iris to minimize wakefield effects is used to boost the drive beam to a useful energy of around 20 MeV for wakefield acceleration experiments. Focusing in the photocathode gun and the preaccelerator is accomplished with solenoids. Beam dynamics simulations throughout the preaccelerator are performed using particle simulation codes TBCI-SF and PARMELA. An example providing a useful set of operation parameters for the Argonne Wakefield Accelerator is given. The effects of the sagitta of the curved beam and laser amplitude and timing jitter effects are discussed. Measurement results of low rf power level bench tests and a high power test for the gun cavity are presented and discussed

  9. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  10. Pulsed eddy current inspection of CF-188 inner wing spar

    Science.gov (United States)

    Horan, Peter Francis

    Royal Canadian Air Force (RCAF) CF-188 Hornet aircraft engineering authorities have stated a requirement for a Non-Destructive Evaluation (NDE) technique to detect Stress Corrosion Cracking (SCC) in the inner wing spars without fastener or composite wing skin removal. Current radiographic inspections involve significant aircraft downtime, and Pulsed Eddy Current (PEC) inspection is proposed as a solution. The aluminum inner wing spars of CF-188 Hornet aircraft may undergo stress corrosion cracking (SCC) along the spar between the fasteners that secure carbon-fiber/ epoxy composite skin to the wing. Inspection of the spar through the wing skin is required to avoid wing disassembly. The thickness of the wing skin varies between 8 and 20 mm (0.3 to 0.8 inch) and fasteners may be either titanium or ferrous. PEC generated by a probe centered over a fastener, demonstrates capability of detecting simulated cracks within spars with the wing skin present. Comparison of signals from separate sensors, mounted to either side of the excitation coil, is used to detect differences in induced eddy current fields, which arise in the presence of cracks. To overcome variability in PEC signal response due to variation in 1) skin thickness, 2) fastener material and size, and 3) centering over fasteners, a large calibration data set is acquired. Multi-dimensional scores from a Modified Principal Components Analysis (PCA) of the data are reduced to one dimension (1D) using a Discriminant Analysis method. Under inspection conditions, calibrated PCA scores combined with discriminant analysis permit rapid real time go/no-go PEC detection of cracks in CF-188 inner wing spar. Probe designs using both pickup coils and Giant Magnetoresistive (GMR) sensors were tested on samples with the same ferrous and titanium fasteners found on the CF-188. Flaws were correctly detected at lift-offs of up to 21mm utilizing a variety of insulating skin materials simulating the carbon-fibre reinforced polymer

  11. Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging.

    Science.gov (United States)

    Josan, Sonal; Pauly, John M; Daniel, Bruce L; Pauly, Kim Butts

    2009-05-01

    Ultrashort echo time imaging with half RF pulse excitation is challenging as eddy currents induced by the slice-select gradient distort the half pulse slice profile. This work presents two pulses with T(2)-dependent slice profiles that are less sensitive to eddy currents. The double half pulse improves the slice selectivity for long T(2) components, while the inverted double half pulse suppresses the unwanted long T(2) signal. Thus, both approaches prevent imperfect cancellation of out-of-slice signal from contaminating the desired slice. Experimental results demonstrate substantially improved slice selectivity and R(2)* quantitation accuracy with these pulses. These pulses are effective in making short T(2) imaging and quantitation less sensitive to eddy currents and provide an alternative to time-consuming gradient characterization. (c) 2009 Wiley-Liss, Inc.

  12. The study of Zn–Co alloy coatings electrochemically deposited by pulse current

    Directory of Open Access Journals (Sweden)

    Tomić Milorad V.

    2012-01-01

    Full Text Available The electrochemical deposition by pulse current of Zn-Co alloy coatings on steel was examined, with the aim to find out whether pulse plating could produce alloys that could offer a better corrosion protection. The influence of on-time and the average current density on the cathodic current efficiency, coating morphology, surface roughness and corrosion stability in 3% NaCl was examined. At the same Ton/Toff ratio the current efficiency was insignificantly smaller for deposition at higher average current density. It was shown that, depending on the on-time, pulse plating could produce more homogenous alloy coatings with finer morphology, as compared to deposits obtained by direct current. The surface roughness was the greatest for Zn-Co alloy coatings deposited with direct current, as compared with alloy coatings deposited with pulse current, for both examined average current densities. It was also shown that Zn-Co alloy coatings deposited by pulse current could increase the corrosion stability of Zn-Co alloy coatings on steel. Namely, alloy coatings deposited with pulse current showed higher corrosion stability, as compared with alloy coatings deposited with direct current, for almost all examined cathodic times, Ton. Alloy coatings deposited at higher average current density showed greater corrosion stability as compared with coatings deposited by pulse current at smaller average current density. It was shown that deposits obtained with pulse current and cathodic time of 10 ms had the poorest corrosion stability, for both investigated average deposition current density. Among all investigated alloy coatings the highest corrosion stability was obtained for Zn-Co alloy coatings deposited with pulsed current at higher average current density (jav = 4 A dm-2.

  13. Biphasic response of action potential duration to metabolic inhibition in rabbit and human ventricular myocytes: role of transient outward current and ATP-regulated potassium current

    NARCIS (Netherlands)

    Verkerk, A. O.; Veldkamp, M. W.; van Ginneken, A. C.; Bouman, L. N.

    1996-01-01

    Inhibition of cell metabolism is associated with significant changes in action potential duration. The aim of this study was to investigate the time course of the changes in action potential duration during metabolic inhibition and to determine what changes in membrane currents are responsible. The

  14. Current indications and new applications of intense pulsed light.

    Science.gov (United States)

    González-Rodríguez, A J; Lorente-Gual, R

    2015-06-01

    Intense pulsed light (IPL) systems have evolved since they were introduced into medical practice 20 years ago. Pulsed light is noncoherent, noncollimated, polychromatic light energy emitted at different wavelengths that target specific chromophores. This selective targeting capability makes IPL a versatile therapy with many applications, from the treatment of pigmented or vascular lesions to hair removal and skin rejuvenation. Its large spot size ensures a high skin coverage rate. The nonablative nature of IPL makes it an increasingly attractive alternative for patients unwilling to accept the adverse effects associated with other procedures, which additionally require prolonged absence from work and social activities. In many cases, IPL is similar to laser therapy in effectiveness, and its versatility, convenience, and safety will lead to an expanded range of applications and possibilities in coming years. Copyright © 2014 Elsevier España, S.L.U. and AEDV. All rights reserved.

  15. Letter Report on 500 nA Pulsed Current from Field Ionization Source

    International Nuclear Information System (INIS)

    Ellsworth, Jennifer L.

    2013-01-01

    We recently produced a milestone 500 nA of pulsed current using 40 Ir field ionizer electrodes in our ion source. In conclusion, we have produced the milestone pulsed current of 500 nA using 40 electrochemically etched iridium tips in a field ionization source. The pulsed current output is repeatable and scales as expected with gas fill pressure and bias voltage. We expect these current will be sufficient to produce neutral yields of 1 · 10 7 DT n/s.

  16. Design and development of a low-cost biphasic charge-balanced functional electric stimulator and its clinical validation.

    Science.gov (United States)

    Shendkar, Chandrashekhar; Lenka, Prasanna K; Biswas, Abhishek; Kumar, Ratnesh; Mahadevappa, Manjunatha

    2015-10-01

    Functional electric stimulators that produce near-ideal, charge-balanced biphasic stimulation waveforms with interphase delay are considered safer and more efficacious than conventional stimulators. An indigenously designed, low-cost, portable FES device named InStim is developed. It features a charge-balanced biphasic single channel. The authors present the complete design, mathematical analysis of the circuit and the clinical evaluation of the device. The developed circuit was tested on stroke patients affected by foot drop problems. It was tested both under laboratory conditions and in clinical settings. The key building blocks of this circuit are low dropout regulators, a DC-DC voltage booster and a single high-power current source OP-Amp with current-limiting capabilities. This allows the device to deliver high-voltage, constant current, biphasic pulses without the use of a bulky step-up transformer. The advantages of the proposed design over the currently existing devices include improved safety features (zero DC current, current-limiting mechanism and safe pulses), waveform morphology that causes less muscle fatigue, cost-effectiveness and compact power-efficient circuit design with minimal components. The device is also capable of producing appropriate ankle dorsiflexion in patients having foot drop problems of various Medical Research Council scale grades.

  17. Featuring of transient tunneling current by voltage pulse and application to an electrochemical biosensor

    Science.gov (United States)

    Yun, Jun Yeon; Lee, Won Cheol; Choi, Seong Wook; Park, Young June

    2018-03-01

    We suggest a voltage pulse method for detecting the transient tunneling current component (faradaic current component) in a metal/redox-active monolayer/electrolyte system. After applying the pulse to the metal electrode, the capacitive current prevails; therefore, it is difficult to extract the tunneling current, which carries information on the biochemical reactions occurring between the biomarkers in the electrolyte and the self-assembled monolayer (SAM) as the probe peptide system. Instead of waiting until the capacitive current diminishes, and thereby, the tunneling current also decreases, we try to extract the tunneling current in an early stage of the pulse. The method is based on the observation that the capacitive current becomes symmetrized in the positive and negative pulses after introducing the SAM on the metal electrode. When the energy level of the redox molecule is higher than the Fermi level of the metal under zero-bias condition, the tunneling current in the negative pulse can be extracted by subtracting the capacitive current obtained from the positive pulse, where the tunneling current is neglected. The experiment conducted for detecting trypsin as a biomarker shows that the method enhances the sensitivity and the specific-to-nonspecific ratio of the sensor device in the case of the nonspecific protein-abundant electrolyte solution, as evinced by cyclic voltammetry measurements in comparison.

  18. Harp, a short pulse, high current electron beam accelerator

    International Nuclear Information System (INIS)

    Prestwich, K.R.

    1974-01-01

    A 3 MV, 800 kA, 24 ns electron beam accelerator is described and the results of initial switching experiments are discussed. The generator will provide a source for studying the physics of processes leading to electron beam driven, inertially confined fusion. The major components of the accelerator are two diodes with a common anode, twelve oil-dielectric Blumleins with low jitter (less than 2 ns) multichannel switches, three intermediate storage capacitors, a trigger pulse generator and two Marx generators. (U.S.)

  19. Thyristor current-pulse generator for betatron electromagnet with independent low-voltage supply

    International Nuclear Information System (INIS)

    Baginskii, B.A.; Makarevich, V.N.; Shtein, M.M.

    1989-01-01

    A thyristor generator is described that produces unipolar current pulses in the winding of a betatron electromagnet. The voltage on the electro-magnet is increased and the shape of the current pulses is improved by use of an intermediate inductive storage device. The current pulses have a duration of 11 msec, an amplitude of 190 A, and a repetition frequency of 50 Hz. The maximum magnetic-field energy is 450 J, the voltage on the electromagnet winding is 1.5 kV, and the supply voltage is 27 V

  20. The effect of pulse current on energy saving during Electrochemical Chloride Extraction (ECE) in concrete

    DEFF Research Database (Denmark)

    Sun, Tian R.; Geiker, Mette R.; Ottosen, Lisbeth M.

    2012-01-01

    Energy consumption is a factor influencing the cost of Electrochemical Chloride Extraction (ECE) in concrete. The aims of this work were to investigate the possibility for energy saving when using a pulsed electric field during ECE and the effect of the pulsed current on removal of chloride. Four...

  1. Analysis of effective pulse current charging method for lithium ion battery

    Science.gov (United States)

    Majid, N.; Hafiz, S.; Arianto, S.; Yuono, R. Y.; Astuti, E. T.; Prihandoko, B.

    2017-04-01

    Pulse charging methods has been developed as one of the fast charging methods for Lithium ion battery. This technique applies the continuous constant current pulse with certain pulse width until the battery fully charged. In this research, four Lithium polymer batteries of same type and capacity were used and subjected by several current pulses as a variable. The phenomenon of capacity loss as an effect of charging method was analysed every ten charge-discharge cycles. Four batteries were charged using constant current (1C) for 30 minutes to fill half of the total capacity, which then continued by pulse current of different pulse width in order to reach full capacity of each battery. Constant current charging for one hour was also applied to each battery as a comparison with that of pulse current charging data. The similar degradation patterns on battery capacity were observed. Nevertheless, the percentage of capacity loss is different. In conclusion, this method can be considered as one of the effective charging method, owing to the smallest capacity loss and shorter charging time.

  2. Development of optoelectronic-based pulsed current sensor to ...

    Indian Academy of Sciences (India)

    Anil S Nayak

    2017-08-03

    Aug 3, 2017 ... A current transformer (CT)-based sensor has been developed to detect poor discharge conditions in copper vapour ... operator to initiate safety measures. Current ... The threshold value depends on the current flowing through the bypass inductor, which is an indication of the discharge condition of the CVL.

  3. Development of high current electron source using photoemission from metals with ultrashort laser pulses

    International Nuclear Information System (INIS)

    Tsang, T.; Srinivasan-Rao, T.; Fischer, J.

    1990-10-01

    We summarize the studies of photoemission from metal photocathodes using picosecond pulses in the UV (4.66 eV) wavelength and femtosecond laser pulses in the visible (2 eV) wavelengths. To achieve high current density yield from metal photocathodes, multiphoton photoemission using femtosecond laser pulses are suggested. Electron yield improvement incorporating surface photoemission and surface plasmon resonance in metals and metal films are demonstrated. We examine the possibility of the nonlinear photoemission process overtaking the linear process, and identity some possible complexity. To extract the large amount of electrons free of space charge, a pulsed high voltage is designed; the results of the preliminary test are presented. Finally, for the first time, the width of the electron temporal profiles are measured, utilizing the nonlinear photoelectric effect, to below 100 fsec time regime. The results indicated that the electron pulse duration follows the laser pulses and are not limited by the material. 8 refs., 15 figs

  4. Multichannel computerized control system of current pulses in LIU-30 electron accelerator

    CERN Document Server

    Gerasimov, A I; Kulgavchuk, V V; Pluzhnikov, A V

    2002-01-01

    In LIU-30 power linear pulsed induction electron accelerator (40 MeV, 10 kA, 25 ns) 288 radial lines with water insulation serve as energy accumulators and shapers of accelerating voltage pulses. The lines are charged simultaneously up to 500 kV using a system comprising 72 Arkadiev-Marx screened generators. To control parameter of synchronous pulses of charging current with up to 60 kA amplitude and 0.85 mu s duration in every of 72 charging circuits one applies a computer-aided system. Current pulse is recorded at output of every generator using the Rogowski coil signal from which via a cable line is transmitted to an analog-digital converter, is processed with 50 ns sampling and is recorded to a memory unit. Upon actuation of accelerator the signals are sequentially or selectively displayed and are compared with pulse typical shape

  5. A low energy, high current, pulsed electron gun for Time-of-flight mass spectrometers

    International Nuclear Information System (INIS)

    Reddy, Pratap; Rao, K.C.; Sule, Uday; Rodrigues, S.M.; Bhushan, K.G.

    2015-01-01

    A compact, low energy, high current pulsed electron gun specifically intended for use in time-of-flight mass spectrometers has been developed. The electron gun consists of a thoriated tungsten hairpin type filament, a wehnelt electrode, series of extracting electrodes, an x-y deflector and a set of pulsing electrodes, all mounted on a CF35 conflat flange. The electron gun delivers ∼ 1 mA of current at 70 eV, in the dc mode. The gun can be pulsed in nanosecond pulses with a repetition rate of upto 50 KHz which can be externally synchronized with conventional time-of-flight electronics. The design and performance of the electron gun over the energy range 20eV to 500 eV is presented along with the pulsing mode operation demonstrated in a time-of-flight mass spectrometer. (author)

  6. The effect of pulse current on energy saving during Electrochemical Chloride Extraction (ECE) in concrete

    DEFF Research Database (Denmark)

    Sun, Tian R.; Geiker, Mette R.; Ottosen, Lisbeth M.

    2012-01-01

    Energy consumption is a factor influencing the cost of Electrochemical Chloride Extraction (ECE) in concrete. The aims of this work were to investigate the possibility for energy saving when using a pulsed electric field during ECE and the effect of the pulsed current on removal of chloride. Four...... experiments with artificially polluted concrete under same charge transfer were conducted. Results showed that the energy consumption was decreased 15% by pulse current in experiments with 0.2 mA/cm2 current density, which was higher than that of 0.1 mA/cm2 experiments with a decrease of 9.6%. When comparing...... the voltage drop at different parts of the experimental cells, it was found that the voltage drop of the area across the concrete was the major contributor to energy consumption, and results indicated that the pulse current could decrease the voltage drop of this part by re-distribution of ions in pore fluid...

  7. Nanosecond field emitted and photo-field emitted current pulses from ZrC tips

    International Nuclear Information System (INIS)

    Ganter, R.; Bakker, R.J.; Gough, C.; Paraliev, M.; Pedrozzi, M.; Le Pimpec, F.; Rivkin, L.; Wrulich, A.

    2006-01-01

    In order to find electron sources with low thermal emittance, cathodes based on single tip field emitter are investigated. Maximum peak current, measured from single tip in ZrC with a typical apex radius around 1 μm, are presented. Voltage pulses of 2 ns duration and up to 50 kV amplitude lead to field emission current up to 470 mA from one ZrC tip. Combination of high applied electric field with laser illumination gives the possibility to modulate the emission with laser pulses. Nanoseconds current pulses have been emitted with laser pulses at 1064 nm illuminating a ZrC tip under high-DC electric field. The dependence of photo-field emitted current with the applied voltage can be explained by the Schottky effect

  8. Application-oriented research on plasma channeling of a large pulsed current

    International Nuclear Information System (INIS)

    Liu Jingye

    2000-01-01

    Utilizing the avalanche effect of plasma produced by the collision of energetic primary electrons with hydrogen molecules in a plasma, channeling of a large pulsed current is achieved, with the plasma acting as the carrier

  9. Low-noise pulsed current source for magnetic-field measurements of magnets for accelerators

    Science.gov (United States)

    Omelyanenko, M. M.; Borisov, V. V.; Donyagin, A. M.; Khodzhibagiyan, H. G.; Kostromin, S. A.; Makarov, A. A.; Shemchuk, A. V.

    2017-01-01

    The schematic diagram, design, and technical characteristics of the pulsed current source developed and produced for the magnetic-field measurement system of superconducting magnets for accelerators are described. The current source is based on the current regulator with pass transistor bank in the linear mode. Output current pulses (0-100 A) are produced by utilizing the energy of the preliminarily charged capacitor bank (5-40 V), which is additionally charged between pulses. The output current does not have the mains frequency and harmonics ripple. The relative noise level is less than-100 dB (or 10-5) of RMS value (it is defined as the ratio of output RMS noise current to a maximal output current of 100 A within the operating bandwidth, expressed in dB). The work was performed at the Veksler and Baldin Laboratory of High Energy Physics, Joint Institute for Nuclear Research (JINR).

  10. Picosecond stability of injection of parallel high-current pulsed electron beams

    Science.gov (United States)

    Yalandin, M. I.; Reutova, A. G.; Ul'Maskulov, M. R.; Sharypov, K. A.; Shpak, V. G.; Shunailov, S. A.; Klimov, A. I.; Rostov, V. V.; Mesyats, G. A.

    2009-09-01

    The stability of operation of parallel explosive-emission cathodes driven by a split high-voltage pulse with a subnanosecond leading front has been studied. It is established that, upon the training of graphite cathodes in vacuum with up to ˜104 pulses, the current pulse fronts of injected high-current electron beams exhibit a mutual temporal dispersion not exceeding ten picoseconds. The dynamics of this parameter during the training stage, the variation of the absolute spread, and the growth of a relative delay of the moments of beam injection have been investigated.

  11. Experimental investigation of powerful pulse current generators based on capacitive storage and explosive magnetic generators

    Science.gov (United States)

    Shurupov, A. V.; Zavalova, V. E.; Kozlov, A. V.; Shurupov, M. A.; Povareshkin, M. N.; Kozlov, A. A.; Shurupova, N. P.

    2018-01-01

    Experimental models of microsecond duration powerful generators of current pulses on the basis of explosive magnetic generators and voltage impulse generator have been developed for the electromagnetic pulse effects on energy facilities to verify their stability. Exacerbation of voltage pulse carried out through the use of electro explosive current interrupter made of copper wires with diameters of 80 and 120 μm. Experimental results of these models investigation are represented. Voltage fronts about 100 ns and the electric field strength of 800 kV/m are registered.

  12. The detailed characteristics of positive corona current pulses in the line-to-plane electrodes

    Science.gov (United States)

    Xuebao, LI; Dayong, LI; Qian, ZHANG; Yinfei, LI; Xiang, CUI; Tiebing, LU

    2018-05-01

    The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investigated in order to reveal their generation mechanism. In this paper, the line-to-plane electrodes are designed to measure and analyze the characteristics of corona current pulses from positive corona discharges. The influences of inter-electrode gap and line diameters on the detail characteristics of corona current pulses, such as pulse amplitude, rise time, duration time and repetition frequency, are carefully analyzed. The obtained results show that the pulse amplitude and the repetition frequency increase with the diameter of line electrode when the electric fields on the surface of line electrodes are same. With the increase of inter-electrode gap, the pulse amplitude and the repetition frequency first decrease and then turn to be stable, while the rise time first increases and finally turns to be stable. The distributions of electric field and space charges under the line electrodes are calculated, and the influences of inter-electrode gap and line electrode diameter on the experimental results are qualitatively explained.

  13. Manipulation of high-current pulses for heavy-ion fusion

    International Nuclear Information System (INIS)

    Sharp, W.M.; Callahan, D.A.; Griedman, A.; Grote, D.P.

    1996-01-01

    For efficient induction-driven heavy-ion fusion, the current profile along a pulse must be modified in a non-selfsimilar manner between the accelerator and the target. In the accelerator, the pulse should have a duration of at least 50 ns in order to make efficient use of the induction cores, and the current should by nearly uniform along the pulse to minimize the aperture. In contrast, the optimal current profile on target consists of a main pulse of about 10 ns preceded by a longer low-current 'foot.' This pulse-shape manipulation must be carried out at the final pulse energy (5-10 GeV for 200 amu ions) in the presence of a large nonlinear longitudinal space-charge field. A straightforward method is presented here for doing the required pulse shaping. Induction-ceU voltages are generated using idealized beam profiles both in the accelerator and on target, and they are verified and checked for error sensitivity using the fluid/envelope code CIRCE

  14. Optimizing pulsed current micro plasma arc welding parameters to ...

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 3, No 6 (2011) >. Log in or Register to get access to full text downloads.

  15. Formability of Al 5xxx Sheet Metals Using Pulsed Current for Various Heat Treatments

    Energy Technology Data Exchange (ETDEWEB)

    Salandro, Wesley A.; Jones, Joshua J.; McNeal, Timothy A.; Roth, John T.; Hong, Sung Tae; Smith, Mark T.

    2010-10-01

    Previous studies have shown that the presence of a pulsed electrical current, applied during the deformation process of an aluminum specimen, can significantly improve the formability of the aluminum without heating the metal above its maximum operating temperature range. The research herein extends these findings by examining the effect of electrical pulsing on 5052 and 5083 Aluminum Alloys. Two different parameter sets were used while pulsing three different heat treatments (As Is, 398°C, and 510°C) for each of the two aluminum alloys. For this research, the electrical pulsing is applied to the aluminum while the specimens are deformed, without halting the deformation process (a manufacturing technique known as Electrically-Assisted Manufacturing). The analysis focuses on establishing the effect the electrical pulsing has on the aluminum alloy’s various heat treatments by examining the displacement of the material throughout the testing region of dogbone-shaped specimens. The results from this research show that pulsing significantly increases the maximum achievable elongation of the aluminum (when compared to baseline tests conducted without electrical pulsing). Another beneficial effect produced by electrical pulsing is that the engineering flow stress within the material is considerably reduced. The electrical pulses also cause the aluminum to deform non-uniformly, such that the material exhibits a diffuse neck where the minimum deformation occurs near the ends of the specimen (near the clamps) and the maximum deformation occurs near the center of the specimen (where fracture ultimately occurs). This diffuse necking effect is similar to what can be experienced during superplastic deformation. However, when comparing the presence of a diffuse neck in this research, electrical pulsing does not create as significant of a diffuse neck as superplastic deformation. Electrical pulsing has the potential to be more efficient than traditional methods of incremental

  16. Low-induction pulse current generator with a volume bus arrangement

    International Nuclear Information System (INIS)

    Bocharov, Yu.N.; Krivosheev, S.I.; Lapin, N.G.; Shneerson, G.A.

    1993-01-01

    Pulse current generator (PC6) with 38 kj stored energy designed for up to 50 kV charging voltage used to obtain magnetic fields within megagauss range, is described. Space (volume) bus arrangement of its modules is used to reduce eigen inductance of PC6. Current is commutated by solid-body spark gaps. Under 3uH inductive load PC6 provides for formation of up to 2.25 MA current pulse with 3.3x10 12 A/s pulse rise time. Technique to determine low inductances as applied to PC6 elements is described. The described PC6 is used for experiments on generation of super-strong pulse magnetic fields in single-loop solenoid with volume occupied by magnetic field, 5-7 mm. Magnetic field with up to 350 T induction amplitude is obtained in these experiments

  17. Optimizing pulsed current micro plasma arc welding parameters to ...

    African Journals Online (AJOL)

    user

    2008; Balasubramanian et al, 2009) it is understood that in most of the works reported the effect of welding current, arc voltage, welding speed, wire feed rate, magnitude of ion gas flow, torch stand-off, plasma gas flow rate on weld quality characteristics like front melting width, back melting width, weld reinforcement, ...

  18. Effects of pulse current on energy consumption and removal of heavy metals during electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian R.; Ottosen, Lisbeth M.

    2012-01-01

    The aims of this paper were to investigate the possibility for energy saving when using a pulsed electric field during electrodialytic soil remediation (EDR) and the effect of the pulsed current on removal of heavy metals. Eight experiments with constant and pulse current in the different...... industrially polluted soils were performed. At a current density of 0.1mA/cm2 in soil 1 and 0.2mA/cm2 in soil 2, there was no difference on energy consumption and removal of heavy metals between pulse current and constant current experiments, but at higher current experiments (i.e., 0.2mA/cm2 in soil 1 and 0.......8mA/cm2 in soil 2) the energy was saved 67% and 60% and the removal of heavy metals was increased 17–76% and 31–51% by pulse current in soil 1 and soil 2, respectively. When comparing the voltage drop at different parts of EDR cells, it was found that the voltage drop of the area across cation...

  19. Pulsed High-Current Experiments at IPP ASci CR Prague

    Science.gov (United States)

    Kolacek, K.; Schmidt, J.; Prukner, V.; Frolov, O.; Straus, J.; Bohacek, V.; Martinkova, M.

    2006-01-01

    The aim of our first high current capillary discharge was to reach amplified spontaneous emission on neon-like argon (λ = 46.9 nm). This was finally accomplished. Our new capillary discharge experiment has larger transverse dimensions, four-channel laser-triggered spark gap, and free optical access to both capillary ends. At present it is electrically tested. In this apparatus the capillary can be replaced by a device with exploding wire in water locally compressed by focused cylindrical converging shock wave (for soft X-ray lasing at shorter wavelength). This part is also at present tested.

  20. Pulsed High-Current Experiments at IPP ASci CR Prague

    International Nuclear Information System (INIS)

    Kolacek, K.; Schmidt, J.; Prukner, V.; Frolov, O.; Straus, J.; Bohacek, V.; Martinkova, M.

    2006-01-01

    The aim of our first high current capillary discharge was to reach amplified spontaneous emission on neon-like argon (λ = 46.9 nm). This was finally accomplished. Our new capillary discharge experiment has larger transverse dimensions, four-channel laser-triggered spark gap, and free optical access to both capillary ends. At present it is electrically tested. In this apparatus the capillary can be replaced by a device with exploding wire in water locally compressed by focused cylindrical converging shock wave (for soft X-ray lasing at shorter wavelength). This part is also at present tested

  1. Understanding the molecular mechanism of pulse current charging for stable lithium-metal batteries.

    Science.gov (United States)

    Li, Qi; Tan, Shen; Li, Linlin; Lu, Yingying; He, Yi

    2017-07-01

    High energy and safe electrochemical storage are critical components in multiple emerging fields of technologies. Rechargeable lithium-metal batteries are considered to be promising alternatives for current lithium-ion batteries, leading to as much as a 10-fold improvement in anode storage capacity (from 372 to 3860 mAh g -1 ). One of the major challenges for commercializing lithium-metal batteries is the reliability and safety issue, which is often associated with uneven lithium electrodeposition (lithium dendrites) during the charging stage of the battery cycling process. We report that stable lithium-metal batteries can be achieved by simply charging cells with square-wave pulse current. We investigated the effects of charging period and frequency as well as the mechanisms that govern this process at the molecular level. Molecular simulations were performed to study the diffusion and the solvation structure of lithium cations (Li + ) in bulk electrolyte. The model predicts that loose association between cations and anions can enhance the transport of Li + and eventually stabilize the lithium electrodeposition. We also performed galvanostatic measurements to evaluate the cycling behavior and cell lifetime under pulsed electric field and found that the cell lifetime can be more than doubled using certain pulse current waveforms. Both experimental and simulation results demonstrate that the effectiveness of pulse current charging on dendrite suppression can be optimized by choosing proper time- and frequency-dependent pulses. This work provides a molecular basis for understanding the mechanisms of pulse current charging to mitigating lithium dendrites and designing pulse current waveforms for stable lithium-metal batteries.

  2. Pulse shape discrimination with silicon detectors using charge and current-sensitive preamplifiers

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H.; Rauly, E.; Blumenfeld, Y.; Borderie, B.; Chabot, M.; Edelbruck, P.; Lavergne, L.; Le Bris, J.; Le Neindre, N.; Richard, A.; Rivet, M.F.; Scarpaci, J.A.; Barbey, S.; Becheva, E.; Bzyl, F.R.; D' Esesquelles, P.; Galichet, E.; Lalu, G.; Martinet, G.; Pierre, S. [Institut de Physique Nucleaire, IN2P3-CNRS, 91 - Orsay (France); Legou, Th.; Tillier, J.; Bocage, F.; Bougault, R.; Carniol, B.; Cussol, D.; Etasse, D.; Grevy, S.; Lopez, O.; Tamain, B.; Vient, E. [Caen Univ., LPC, IN2P3-CNRS, ENSI, 14 - Caen (France); Galichet, E. [Conservatoire National des Arts et Metier, 75 - Paris (France); Guinet, D.; Lautesse, Ph. [Villeurbanne Univ., Institut de Physique Nucleaire, IN2P3-CNRS, 69 (France); Lanzalone, G. [Catania Univ., INFN, Laboratori Nazionali del Sud and Dipartimento di Fisica e Astronomia, (Italy); Politi, G. [Catania Univ., INFN, Sezione di Catania and Dipartimento di Fisica e Astronomia (Italy); Rosato, E. [Napoli, Univ., Dipt. di Scienze Fisiche e Sezione INFN (Italy)

    2003-07-01

    For the first time shapes of current pulses from light charged particles and carbon ions are presented. Capabilities for pulse shape discrimination techniques are demonstrated. In this work, charge and current-sensitive preamplifier prototypes for nuclear structure and dynamics experiments have been developed and tested with the aim of improving PSD (pulse shape discrimination) method by studying in detail current signal shapes from particles and ions over a large energy range. Note that current signal shapes have been recently used in atomic cluster studies to identify partitions of carbon cluster fragmentation. The paper is organized as follows. Section 2 is devoted to characterization of preamplifiers. In section 3, results of on beam tests will be presented, discussed and compared to a simple simulation.

  3. Effects of pulse current stimulation on the thermal fatigue crack propagation behavior of CHWD steel

    International Nuclear Information System (INIS)

    Lin, H.Q.; Zhao, Y.G.; Gao, Z.M.; Han, L.G.

    2008-01-01

    The fatigue crack propagating behaviors of cast hot working die (CHWD) steel untreated and treated by an electric current in the intermediate stage of thermal fatigue were investigated in the present study. The circle/elliptical heating affected zone (HAZ) was formed ahead of the notch tip on the fatigued specimens after pulse electric current stimulation. Both SEM observation and X-ray diffraction analysis revealed that pulse electric current stimulation refined grains/subgrains in the HAZs. With the prolonging of discharging duration, the grains/subgrains decreased in size and the dislocation density and microhardness increased gradually. The grain refinement and dislocation density increase played an important role in the material strengthening, which inevitably enhanced the propagation resistance and delayed the propagation of thermal fatigue cracks. Therefore, the pulse electric current stimulation was an effective method to improve the service lifetime of die material

  4. Non-Cyanide Electrodeposited Ag–PTFE Composite Coating Using Direct or Pulsed Current Deposition

    Directory of Open Access Journals (Sweden)

    Raymond Sieh

    2016-07-01

    Full Text Available The effects of FC-4 cationic surfactant on electrodeposited Ag–PTFE composite coating using direct or pulsed currents were studied using scanning electron microscope (SEM, energy dispersive X-ray (EDS, optical microscope, and a linear tribometer. FC-4:PTFE in various ratios were added to a non-cyanide succinimide silver complex bath. Direct or pulsed current method was used at a constant current density to enable comparison between both methods. A high incorporation rate of PTFE was successfully achieved, with pulsed current being highly useful in increasing the amount of PTFE in the composite coating. The study of coating wear under sliding showed that a large majority of the electrodeposited coatings still managed to adhere to the substrate, even after 10 wear cycles of sliding tests. Performance improvements were achieved on all the samples with a coefficient of friction (CoF between 0.06 and 0.12.

  5. Observation of dark pulses in 10 nm thick YBCO nanostrips presenting hysteretic current voltage characteristics

    Science.gov (United States)

    Ejrnaes, M.; Parlato, L.; Arpaia, R.; Bauch, T.; Lombardi, F.; Cristiano, R.; Tafuri, F.; Pepe, G. P.

    2017-12-01

    We have fabricated several 10 nm thick and 65 nm wide YBa2Cu3O7-δ (YBCO) nanostrips. The nanostrips with the highest critical current densities are characterized by hysteretic current voltage characteristics (IVCs) with a direct bistable switch from the zero-voltage to the finite voltage state. The presence of hysteretic IVCs allowed the observation of dark pulses due to fluctuations phenomena. The key role of the bistable behavior is its ability to transform a small disturbance (e.g. an intrinsic fluctuation) into a measurable transient signal, i.e. a dark pulse. On the contrary, in devices characterized by lower critical current density values, the IVCs are non-hysteretic and dark pulses have not been observed. To investigate the physical origin of the dark pulses, we have measured the bias current dependence of the dark pulse rate: the observed exponential increase with the bias current is compatible with mechanisms based on thermal activation of magnetic vortices in the nanostrip. We believe that the successful amplification of small fluctuation events into measurable signals in nanostrips of ultrathin YBCO is a milestone for further investigation of YBCO nanostrips for superconducting nanostrip single photon detectors and other quantum detectors for operation at higher temperatures.

  6. Pulse Current Assisted TLP Bonding of SiCP/Al Composites Sheet Using Powders Interlayer

    Directory of Open Access Journals (Sweden)

    WANG Bo

    2017-06-01

    Full Text Available The powders interlayer was applied for transient liquid phase (TLP bonding of SiCp/Al composites using pulse current heating. Pulse current got though the joint with powder interlayer and generated the effect of Joule heat and spark plasma sintering to achieve the TLP bonding of SiCp/Al composites sheet. The results show that there is the good TLP bonded joint without defects under the conditions of vacuum:1.39×103 Pa; Pulse current density: 115 A/mm2; holding time: 15-60 min; original pressure: 0.5 MPa. The results reveal the dense joint without pores composed of the Al-based solid solution, pure Ti zone, Al2Cu, and Al3Ti intermetallic phase. Furthermore, the thermal and isothermal effects of pulse current on in situ synthesis of TLP bonded joints of SiCp/Al composites using mixed Al-Cu-Ti powder interlayer are analyzed and discussed. According to microstructure of joint, pulse current promote to in situ form the intermetallic compound, which can provide higher mechanical properties of joint.

  7. Sodium current inhibition by nanosecond pulsed electric field (nsPEF)--fact or artifact?

    NARCIS (Netherlands)

    Verkerk, Arie O.; van Ginneken, Antoni C. G.; Wilders, Ronald

    2013-01-01

    In two recent publications in Bioelectromagnetics it has been demonstrated that the voltage-gated sodium current (I(Na)) is inhibited in response to a nanosecond pulsed electric field (nsPEF). At the same time, there was an increase in a non-inactivating "leak" current (I(leak)), which was

  8. Characterization of a high-power/current pulsed magnetized arc discharge

    NARCIS (Netherlands)

    Zielinski, J. J.; van der Meiden, H. J.; Morgan, T. W.; D.C. Schram,; De Temmerman, G.

    2012-01-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 mu F) is parallel-coupled to the current regulated power supply. The current is transiently increased from

  9. Proposal of Application of Pulsed Vision Chip for Retinal Prosthesis

    Science.gov (United States)

    Ohta, Jun; Yoshida, Norikatsu; Kagawa, Keiichiro; Nunoshita, Masahiro

    2002-04-01

    A vision chip based on pulse frequency modulation (PFM) is proposed as a retinal prosthesis device for use in subretinal implantation. A pixel circuit of PFM has been fabricated using standard CMOS technology. A dynamic range of 40 dB is demonstrated at a low power supply voltage of 1 V. It is found that the competition between the charge current to the photodiode and the photocurrent affects the output pulse characteristics under the conditionds of low power supply voltage and strong light illumination. For in vitro and in vivo experiments, two methods of improving the PFM circuits are considered. One is controlling the pulse frequency. By adding one transistor to the PFM circuit, the output pulse frequency can be experimentally controlled by a factor of two. The other is using a biphasic output, which is required to keep a charge balance in a living body. By introducing differential circuits, the biphasic output has been confirmed by simulation.

  10. Analysis of integrated thyristor switching-off by a reverse gate pulse current

    Science.gov (United States)

    Grekhov, I. V.; Lyublinsky, A. G.; Mikhailov, E. M.; Poloskin, D. S.; Skidanov, A. A.

    2017-11-01

    To increase the maximum power current density of an integrated n + p'Nn'p +-type thyristor during switching-off by a current pulse in the control circuit, the injection of electrons from the n + emitter should be interrupted before the recovery of the collector p'N junction. This has been done using a rapidly increasing reverse gate current pulse with an amplitude equal to the amplitude of the power switched-off current. After the interruption of the emitter injection, the remaining current through the device is the current of holes extracted from the collector region via the gate electrode. Like in insulated gate bipolar transistors (IGBTs), the physical mechanism that limits the maximum density of the switch-off current is the dynamic avalanche breakdown, which is initiated by the holes extracted through the space charge region of the collector p'N junctions.

  11. Modified Johnson-Cook model incorporated with electroplasticity for uniaxial tension under a pulsed electric current

    Science.gov (United States)

    Kim, Moon-Jo; Jeong, Hye-Jin; Park, Ju-Won; Hong, Sung-Tae; Han, Heung Nam

    2018-01-01

    An empirical expression describing the electroplastic deformation behavior is suggested based on the Johnson-Cook (JC) model by adding several functions to consider both thermal and athermal electric current effects. Tensile deformation behaviors are carried out for an AZ31 magnesium alloy and an Al-Mg-Si alloy under pulsed electric current at various current densities with a fixed duration of electric current. To describe the flow curves under electric current, a modified JC model is proposed to take the electric current effect into account. Phenomenological descriptions of the adopted parameters in the equation are made. The modified JC model suggested in the present study is capable of describing the tensile deformation behaviors under pulsed electric current reasonably well.

  12. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    Science.gov (United States)

    Tallouli, M.; Shyshkin, O.; Yamaguchi, S.

    2017-07-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  13. Effect of a superconducting coil as a fault current limiter on current density distribution in BSCCO tape after an over-current pulse

    International Nuclear Information System (INIS)

    Tallouli, M; Yamaguchi, S.; Shyshkin, O.

    2017-01-01

    The development of power transmission lines based on long-length high temperature superconducting (HTS) tapes is complicated and technically challenging task. A serious problem for transmission line operation could become HTS power cable damage due to over-current pulse conditions. To avoid the cable damage in any urgent case the superconducting coil technology, i.e. superconductor fault current limiter (SFCL) is required. Comprehensive understanding of the current density characteristics of HTS tapes in both cases, either after pure over-current pulse or after over-current pulse limited by SFCL, is needed to restart or to continue the operation of the power transmission line. Moreover, current density distribution along and across the HTS tape provides us with the sufficient information about the quality of the tape performance in different current feeding regimes. In present paper we examine BSCCO HTS tape under two current feeding regimes. The first one is 100A feeding preceded by 900A over-current pulse. In this case none of tape protection was used. The second scenario is similar to the fist one but SFCL is used to limit an over-current value. For both scenarios after the pulse is gone and the current feeding is set up at 100A we scan magnetic field above the tape by means of Hall probe sensor. Then the feeding is turned of and the magnetic field scanning is repeated. Using the inverse problem numerical solver we calculate the corresponding direct and permanent current density distributions during the feeding and after switch off. It is demonstrated that in the absence of SFCL the current distribution is highly peaked at the tape center. At the same time the current distribution in the experiment with SFCL is similar to that observed under normal current feeding condition. The current peaking in the first case is explained by the effect of an opposite electric field induced at the tape edges during the overcurrent pulse decay, and by degradation of

  14. Nanosecond electric pulses differentially affect inward and outward currents in patch clamped adrenal chromaffin cells.

    Directory of Open Access Journals (Sweden)

    Lisha Yang

    Full Text Available This study examined the effect of 5 ns electric pulses on macroscopic ionic currents in whole-cell voltage-clamped adrenal chromaffin cells. Current-voltage (I-V relationships first established that the early peak inward current was primarily composed of a fast voltage-dependent Na+ current (INa, whereas the late outward current was composed of at least three ionic currents: a voltage-gated Ca2+ current (ICa, a Ca2+-activated K+ current (IK(Ca, and a sustained voltage-dependent delayed rectifier K+ current (IKV. A constant-voltage step protocol was next used to monitor peak inward and late outward currents before and after cell exposure to a 5 ns pulse. A single pulse applied at an electric (E-field amplitude of 5 MV/m resulted in an instantaneous decrease of ~4% in peak INa that then declined exponentially to a level that was ~85% of the initial level after 10 min. Increasing the E-field amplitude to 8 or 10 MV/m caused a twofold greater inhibitory effect on peak INa. The decrease in INa was not due to a change in either the steady-state inactivation or activation of the Na+ channel but instead was associated with a decrease in maximal Na+ conductance. Late outward current was not affected by a pulse applied at 5 MV/m. However, for a pulse applied at the higher E-field amplitudes of 8 and 10 MV/m, late outward current in some cells underwent a progressive ~22% decline over the course of the first 20 s following pulse exposure, with no further decline. The effect was most likely concentrated on ICa and IK(Ca as IKV was not affected. The results of this study indicate that in whole-cell patch clamped adrenal chromaffin cells, a 5 ns pulse differentially inhibits specific voltage-gated ionic currents in a manner that can be manipulated by tuning E-field amplitude.

  15. Determination of Sulfonamides in Chicken Muscle by Pulsed Direct Current Electrospray Ionization Tandem Mass Spectrometry.

    Science.gov (United States)

    Fu, Xian; Liang, Hengxing; Xia, Bing; Huang, Chunyan; Ji, Baocheng; Zhou, Yan

    2017-09-20

    A simple and rapid approach for the simultaneous detection of trace amounts of six sulfonamides in chicken muscle was developed using pulsed direct current electrospray ionization tandem mass spectrometry (pulsed-dc ESI-MS/MS). The pretreatment of chicken muscle samples consisted of two steps: acetonitrile extraction and n-hexane delipidation. Sulfonamides do not need to be derivatized or chromatographed prior to pulsed-dc ESI-MS/MS. The factors affecting the performance of pulsed-dc ESI-MS/MS were studied. Under optimum conditions, the quantitative performance of pulsed-dc ESI-MS/MS was validated according to European Union Decision 2002/657/EC, and the sensitivity of pulsed-dc ESI-MS/MS was 3 times higher than that of ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The limits of detection obtained by pulsed-dc ESI-MS/MS were in the range of 0.07-0.11 μg/kg. The proposed method was simple, rapid, and sensitive, and was successfully used for quantitation and rapid screening of sulfonamides in real chicken muscle samples.

  16. Review of biphasic insulin aspart in the treatment of type 1 and 2 diabetes

    Directory of Open Access Journals (Sweden)

    Nazia Raja-Khan

    2008-01-01

    Full Text Available Nazia Raja-Khan, Sarah S Warehime, Robert A GabbayDivision of Endocrinology, Diabetes, and Metabolism, Penn State Institute for Diabetes and Obesity, Pennsylvania State University College of Medicine, Hershey, Pennsylvania, USABackground: Insulin is an effective treatment for achieving glycemic control and preventing complications in patients with diabetes. In order to make insulin therapy more acceptable to patients, newer formulations of insulin have been developed, such as biphasic insulins. Biphasic insulins conveniently provide both prandial and basal insulin in a single injection. One of the most well-studied biphasic insulins is biphasic insulin aspart 70/30.Objective: Our goal was to review the current literature on the safety and efficacy of biphasic insulin aspart in type 1 and type 2 diabetes.Methods: A MEDLINE search was conducted using the terms “biphasic insulin aspart” to identify clinical studies and reviews.Results: Biphasic insulin aspart more effectively reduces post-prandial glucose compared to other biphasic insulins and basal insulins. Compared to biphasic insulin aspart, fasting glucose levels are lower with NPH, similar with glargine, and similar or lower with biphasic human insulin. Treat-to-target trials have shown that a goal HbA1c below 6.5 or 7% can be achieved with biphasic insulin aspart. The risk of hypoglycemia is similar to or less than that seen with other biphasic insulins or NPH insulin.Conclusion: Biphasic insulin aspart 70/30 is a safe and effective treatment option for patients with diabetes.Keywords: biphasic insulin aspart, insulin, diabetes

  17. High-current pulse electron accelerators based on stepped forming lines

    CERN Document Server

    Gordeev, V S; Filipov, V O; Petrov, A N; Gridasov, A P

    2001-01-01

    There presented is a brief review of I-3000, STRAUS, STRAUS-2 and LIA-10M accelerators produced in VNIEF over the period from 1981 to 1994. All the installations function in the mode of single pulses. Their distinction consists in using the systems of forming high-voltage pulses on the basis of stepped forming lines. Such installations formed of line sections of a similar electrical length with a stepped character of impedance variance provide a high efficiency and as a result of wave processes increase for a several time the output voltage as compared to the charge voltage of lines. The limiting energy of accelerated electrons for the created accelerators lies within the range from 2.3 to 25 MeV, beam current amplitude - from 20 to 50 kA, current pulse width at half-height - from 16 to 40 ns. The basic characteristics of each accelerator are presented.

  18. Paired-pulse depression of excitatory postsynaptic current sinks in hippocampal CA1 in vivo.

    Science.gov (United States)

    Leung, L Stan; Peloquin, Pascal; Canning, Kevin J

    2008-01-01

    Paired-pulse depression (PPD), a short-term neural plasticity, was studied in hippocampal CA1 of urethane-anesthetized rats in vivo, using field potential recordings and current source density analysis. PPD was robust when an ipsilateral CA3 (iCA3) conditioning pulse of moderate stimulus intensity was followed 30-200 ms later by a contralateral CA3 (cCA3) test pulse; the ratio of the conditioned (C) to the nonconditioned (NC) response, as measured by the peak excitatory sink at the apical dendrites, ranged from 0.6 to 0.8. An alveus conditioning pulse evoked a large antidromic population spike in CA1 and a modest depression of the CA3-evoked excitatory sink (C/NC ratio of approximately 0.85). High-intensity paired pulses, both delivered to iCA3, also showed PPD of the proximal excitatory sinks; however, paired-pulse facilitation of the dendritic sinks was found at the mid-apical dendrites, >250 microm from the soma. Local injection of GABA(A) antagonist picrotoxin or bicuculline increased the C/NC ratio at IPIs of sinks was caused by mainly feedforward and some feedback inhibition at the apical dendrites. GABA(A)-mediated postsynaptic inhibition dominated at early latencies, while GABA(B)-mediated inhibition prevailed at long latencies, probably at both presynaptic and postsynaptic sites. PPD of the excitatory sinks provides a measure of population dendritic inhibition in vivo.

  19. Criteria for fluxon generation in long Josephson junctions by current pulses

    DEFF Research Database (Denmark)

    Sakai, S.; Samuelsen, Mogens Rugholm

    1987-01-01

    In recent measurements in the time domain on the fluxon shape in long Josephson junctions the fluxons were generated by a current pulse injected into one end. We present here a perturbation treatment of the fluxon generation which we compare with numerical experiments. The agreement turns out to ...... to be excellent. Applied Physics Letters is copyrighted by The American Institute of Physics....

  20. Loeb's and streamer-based mechanism for negative corona current pulses

    International Nuclear Information System (INIS)

    Vagnerova, L.; Skalny, J.D.; Cermak, M.

    1998-01-01

    The negative point-to-plane corona discharge in electronegative gaseous mixtures is studied experimentally and the basic mechanisms controlling the corona phenomena are discussed. The typical shapes of the current pulse waveforms observed in experiments with the nitrogen-freon mixtures are explained in terms of the theory by Loeb and of the positive-streamer-based model. (J.U.)

  1. Spin current generation by ultrafast laser pulses in ferromagnetic nickel films

    Science.gov (United States)

    Hurst, Jérôme; Hervieux, Paul-Antoine; Manfredi, Giovanni

    2018-01-01

    A semiclassical phase-space model is used to study the ultrafast charge and spin dynamics in thin ferromagnetic films. Both itinerant and localized magnetism are taken into account. It is shown that an oscillating spin current can be generated in the film via the application of a femtosecond laser pulse in the visible range.

  2. Thermoelectric properties of SiC/C composites from wood charcoal by pulse current sintering

    NARCIS (Netherlands)

    Fujisawa, M; Hata, T; Bronsveld, P; Castro, [No Value; Tanaka, F; Kikuchi, H; Imamura, Y

    2005-01-01

    SiC/C composites were investigated by sintering a mix of wood charcoal and SiO2 powder (32-45 mu m) at 1400, 1600 and 1800 degrees C under N-2 atmosphere with a pulse current sintering method. Thermoelectric properties of SiC/C composites were investigated by measuring the Seebeck coefficient and

  3. High-current relativistic klystron amplifier development for microsecond pulse lengths

    International Nuclear Information System (INIS)

    Fazio, M.V.; Carlsten, B.E.; Faehl, R.; Kwan, T.J.; Rickel, D.G.; Stringfield, R.M.; Tallerico, P.J.

    1991-01-01

    Los Alamos is extending the performance of the Friedman-type, high-current relativistic klystron amplifier (RKA) to the microsecond regime while attempting to achieve the gigawatt-level peak power capability that has been characteristic of the RKA at shorter pulse lengths. Currently the electron beam power into the device is about 1 GW in microsecond duration pulses, with an effort underway to increase the beam power to 2.5 GW. To data the device has yielded an rf modulated electron beam power of 350 MW, with up to 50 MW coupled into waveguide. Several aspects of RKA operation under investigation that affect RKA beam bunching efficiency and amplifier gain include cavity tuning, beam diameter, beam current, and input rf drive power, and the development of an output coupler that efficiently couples the microwave power from the low impedance beam into rectangular waveguide operating in the dominant mode. Current results from experimental testing and code modeling are presented

  4. Influence of pulse electric current on structure and superconducting properties of high temperature superconductor

    International Nuclear Information System (INIS)

    Rajchenko, A.I.; Flis, A.A.; Chernenko, L.I.; Kryuchkova, N.I.

    1998-01-01

    The influence of high-density pulse current treatment at room temperature on structure and superconducting properties of HTSC Y Ba 2 Cu 3 O x ceramics is studied. The structures of the samples are found to undergo appreciable changes as the density of pulse current is gradually increased from its minimum value; as a certain threshold value is attained, there occurs a melting-off of coarse grains with a partial destroying of intergrain contact areas followed by superconductivity loss. A further increase in the treatment current density results in a restoration of the superconducting properties probably due to the occurrence of aligned-with-current superconducting bridges between the melted-off grains. The superconducting transition temperature in the samples does not charge but subsequent thermal treatment causes this temperature to increase

  5. Negative corona current pulses in argon and in mixture argon with SF6

    International Nuclear Information System (INIS)

    Zahoranova, A.; Zahoran, M.; Bucek, A.; Cernak, M.; Bosko, J.

    2004-01-01

    Waveforms of the first negative current pulses in a short negative point-to plane gap in pure argon and argon with SF 6 admixture have been investigated with a nanosecond time resolution at a gas pressure 50 kPa as a function of applied gap voltage and content of SF 6 in the mixture. We have made an attempt to explain the differences in the discharge development in pure argon and in argon with admixture of SF 6 based on the observed changes of the pulse shape. The experimental results obtained will be discussed in context with existing computer simulation models (Authors)

  6. Thermomagnetic writing on deep submicron-patterned TbFe films by nanosecond current pulse

    International Nuclear Information System (INIS)

    You, Long; Kato, Takeshi; Tsunashima, Shigeru; Iwata, Satoshi

    2009-01-01

    This work studies the heating process for deep submicron-patterned TbFe films to be used in a thermally assisted perpendicular magnetic random access memory's writing scheme. The dependence of the heating power density with the current pulse width required for the successful writing was measured in the investigated range of 5-100 ns. In the case of long current pulse, the heat diffuses dominantly into substrate, which resulted in large variation of the required power/energy density with the patterned size. The power/energy densities required for writing increased as the junction area is reduced. While for the short current pulse width, the power/energy densities became rather independent on the size. The required power density for writing 0.38x0.28 μm 2 patterned films using the pulse width of 5 ns is experimentally estimated to be around P=4.7 mW/μm 2 , corresponding to the energy density of E=23 pJ/μm 2 , under an external field of 100 Oe

  7. Effect of pulsed current welding on fatigue behaviour of high strength aluminium alloy joints

    International Nuclear Information System (INIS)

    Balasubramanian, V.; Ravisankar, V.; Madhusudhan Reddy, G.

    2008-01-01

    High strength aluminium alloys (Al-Zn-Mg-Cu alloys) have gathered wide acceptance in the fabrication of light weight structures requiring high strength-to weight ratio, such as transportable bridge girders, military vehicles, road tankers and railway transport systems. The preferred welding processes of high strength aluminium alloy are frequently gas tungsten arc welding (GTAW) process and gas metal arc welding (GMAW) process due to their comparatively easier applicability and better economy. Weld fusion zones typically exhibit coarse columnar grains because of the prevailing thermal conditions during weld metal solidification. This often results inferior weld mechanical properties and poor resistance to hot cracking. In this investigation, an attempt has been made to refine the fusion zone grains by applying pulsed current welding technique. Rolled plates of 6 mm thickness have been used as the base material for preparing single pass welded joints. Single V butt joint configuration has been prepared for joining the plates. The filler metal used for joining the plates is AA 5356 (Al-5Mg (wt%)) grade aluminium alloy. Four different welding techniques have been used to fabricate the joints and they are: (i) continuous current GTAW (CCGTAW), (ii) pulsed current GTAW (PCGTAW), (iii) continuous current GMAW (CCGMAW) and (iv) pulsed current GMAW (PCGMAW) processes. Argon (99.99% pure) has been used as the shielding gas. Fatigue properties of the welded joints have been evaluated by conducting fatigue test using rotary bending fatigue testing machine. Current pulsing leads to relatively finer and more equi-axed grain structure in gas tungsten arc (GTA) and gas metal arc (GMA) welds. In contrast, conventional continuous current welding resulted in predominantly columnar grain structures. Grain refinement is accompanied by an increase in fatigue life and endurance limit

  8. Evolution of the optimum bidirectional (+/- biphasic) wave for defibrillation.

    Science.gov (United States)

    Geddes, L A; Havel, W

    2000-01-01

    Introduction of the asymmetric bidirectional (+/- biphasic) current waveform has made it possible to achieve ventricular defibrillation with less energy and current than are needed with a unidirectional (monophasic) waveform. The symmetrical bidirectional (sinusoidal) waveform was used for the first human-heart defibrillation. Subsequent studies employed the underdamped and overdamped sine waves, then the trapezoidal (monophasic) wave. Studies were then undertaken to investigate the benefit of adding a second identical and inverted wave; little success rewarded these efforts until it was discovered that the second inverted wave needed to be much less in amplitude to lower the threshold for defibrillation. However, there is no physiologic theory that explains the mechanism of action of the bidirectional wave, nor does any theory predict the optimum amplitude and time dimensions for the second inverted wave. The authors analyze the research that shows that the threshold defibrillation energy is lowest when the charge in the second, inverted phase is slightly more than a third of that in the first phase. An ion-flux, spatial-K+ summation hypothesis is presented that shows the effect on myocardial cells of adding the second inverted current pulse.

  9. Polarization-selective vortex-core switching by tailored orthogonal Gaussian-pulse currents

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Young-Sang; Lee, Ki-Suk; Jung, Hyunsung; Choi, Youn-Seok; Yoo, Myoung-Woo; Han, Dong-Soo; Im, Mi-Young; Fischer, Peter; Kim, Sang-Koog

    2011-05-01

    We experimentally demonstrate low-power-consumption vortex-core switching in magnetic nanodisks using tailored rotating magnetic fields produced with orthogonal and unipolar Gaussian-pulse currents. The optimal width of the orthogonal pulses and their time delay are found, from analytical and micromagnetic numerical calculations, to be determined only by the angular eigenfrequency ωD for a given vortex-state disk of polarization p, such that σ=1/ωD and Δt=π/2p/ωD. The estimated optimal pulse parameters are in good agreement with the experimental results. Finally, this work lays a foundation for energy-efficient information recording in vortex-core cross-point architecture.

  10. Investigation on Microstructure and Mechanical Properties of Continuous and Pulsed Current Gas Tungsten Arc Welded alloy 600

    Science.gov (United States)

    Srikanth, A.; Manikandan, M.

    2018-02-01

    The present study investigates the microstructure and mechanical properties of joints fabricated by Continuous and pulsed current gas tungsten arc welded alloy 600. Welding was done by autogenous mode. The macro examination was carried out to evaluate the welding defects in the weld joints. Optical and Scanning Electron Microscope (SEM) were performed to assess the microstructural changes in the fusion zone. Energy Dispersive Spectroscopy (EDS) analysis was carried to evaluate the microsegregation of alloying elements in the fusion zone. The tensile test was conducted to assess the strength of the weld joints. The results show that no welding defects were observed in the fusion zones of Continuous and Pulsed current Gas Tungsten Arc Welding. The refined microstructure was found in the pulsed current compared to continuous current mode. Microsegregation was not noticed in the weld grain boundary of continuous and pulsed current mode. The pulsed current shows improved mechanical properties compared to the continuous current mode.

  11. Photoinduced electric currents in ring-shaped molecules by circularly polarized laser pulses

    International Nuclear Information System (INIS)

    Nobusada, Katsuyuki; Yabana, Kazuhiro

    2007-01-01

    We have theoretically demonstrated that circularly polarized laser pulses induce electric currents and magnetic moments in ring-shaped molecules Na 10 and benzene. The time-dependent adiabatic local density approximation is employed for this purpose, solving the time-dependent Kohn-Sham equation in real space and real time. It has been found that the electric currents are induced efficiently and persist continuously even after the laser pulses were switched off provided the frequency of the applied laser pulse is in tune with the excitation energy of the electronic excited state with the dipole strength for each molecular system. The electric currents are definitely revealed to be a second-order nonlinear optical response to the magnitude of the electric field. The magnetic dipole moments inevitably accompany the ring currents, so that the molecules are magnetized. The production of the electric currents and the magnetic moments in the present procedure is found to be much more efficient than that utilizing static magnetic fields

  12. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    International Nuclear Information System (INIS)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R.

    2015-01-01

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  13. Preparation of scanning tunneling microscopy tips using pulsed alternating current etching

    Energy Technology Data Exchange (ETDEWEB)

    Valencia, Victor A.; Thaker, Avesh A.; Derouin, Jonathan; Valencia, Damian N.; Farber, Rachael G.; Gebel, Dana A.; Killelea, Daniel R., E-mail: dkillelea@luc.edu [Department of Chemistry and Biochemistry, Loyola University Chicago, 1068 W. Sheridan Rd., Chicago, Illinois 60660 (United States)

    2015-03-15

    An electrochemical method using pulsed alternating current etching (PACE) to produce atomically sharp scanning tunneling microscopy (STM) tips is presented. An Arduino Uno microcontroller was used to control the number and duration of the alternating current (AC) pulses, allowing for ready optimization of the procedures for both Pt:Ir and W tips using a single apparatus. W tips prepared using constant and pulsed AC power were compared. Tips fashioned using PACE were sharper than those etched with continuous AC power alone. Pt:Ir tips were prepared with an initial coarse etching stage using continuous AC power followed by fine etching using PACE. The number and potential of the finishing AC pulses was varied and scanning electron microscope imaging was used to compare the results. Finally, tip quality using the optimized procedures was verified by UHV-STM imaging. With PACE, at least 70% of the W tips and 80% of the Pt:Ir tips were of sufficiently high quality to obtain atomically resolved images of HOPG or Ni(111)

  14. Small-sized monitor of beam current and profile for the proton pulse electrostatic accelerator

    International Nuclear Information System (INIS)

    Getmanov, V.N.

    1985-01-01

    Design and principle of operation of current monitor and beam profile of range-coordinate type are described. Monitor operation peculiarities are discussed using diagnostics of a beam of 330-420 keV electrostatic pulse proton accelerator with a beam current of up to 20 mA, at a current density of up to 23 mA x cm -2 and wth pulse duraton of about 20 μs. The monitor consists of a vacuum-dense foil of 3.0+-0.1 μm in thickness (or 0.81+-0.0x- mg x cm -2 ) two grid electrodes, each containing 12 wires, and as solid copper bottom. Foil serves for chopping off background particles with a path lesser 3.0 μm and stands thermal pulse load up to 0.5 J/cm -2 . Grid electrode wires are oriented perpendicularly to lach other and form a two-coordinate secondary-emisson roughness indicator. The bothhom is used for measuring an absolute value of beam current

  15. Paired associative stimulation targeting the tibialis anterior muscle using either mono or biphasic transcranial magnetic stimulation

    DEFF Research Database (Denmark)

    Mrachacz-Kersting, Natalie; Stevenson, Andrew James Thomas

    2017-01-01

    Paired associative stimulation (PAS) protocols induce plastic changes within the motor cortex. The objectives of this study were to investigate PAS effects targeting the tibialis anterior (TA) muscle using a biphasic transcranial magnetic stimulation (TMS) pulse form and, to determine whether...... a reduced intensity of this pulse would lead to significant changes as has been reported for hand muscles using a monophasic TMS pulse. Three interventions were investigated: (1) suprathreshold PAbi-PAS (n = 11); (2) suprathreshold PAmono-PAS (n = 11) where PAS was applied using a biphasic or monophasic...

  16. Charge and spin current oscillations in a tunnel junction induced by magnetic field pulses

    Energy Technology Data Exchange (ETDEWEB)

    Dartora, C.A., E-mail: cadartora@eletrica.ufpr.br [Electrical Engineering Department, Federal University of Parana (UFPR), C.P. 19011 Curitiba, 81.531-970 PR (Brazil); Nobrega, K.Z., E-mail: bzuza1@yahoo.com.br [Federal Institute of Education, Science and Technolgy of Maranhão (IFMA), Av. Marechal Castelo Branco, 789, São Luís, 65.076-091 MA (Brazil); Cabrera, G.G., E-mail: cabrera@ifi.unicamp.br [Instituto de Física ‘Gleb Wataghin’, Universidade Estadual de Campinas (UNICAMP), C.P. 6165, Campinas 13.083-970 SP (Brazil)

    2016-08-15

    Usually, charge and spin transport properties in tunnel junctions are studied in the DC bias regime and/or in the adiabatic regime of time-varying magnetic fields. In this letter, the temporal dynamics of charge and spin currents in a tunnel junction induced by pulsed magnetic fields is considered. At low bias voltages, energy and momentum of the conduction electrons are nearly conserved in the tunneling process, leading to the description of the junction as a spin-1/2 fermionic system coupled to time-varying magnetic fields. Under the influence of pulsed magnetic fields, charge and spin current can flow across the tunnel junction, displaying oscillatory behavior, even in the absence of DC bias voltage. A type of spin capacitance function, in close analogy to electric capacitance, is predicted.

  17. VME computer monitoring system of KEK-PS fast pulsed magnet currents and beam intensities

    International Nuclear Information System (INIS)

    Kawakubo, T.; Akiyama, A.; Kadokura, E.; Ishida, T.

    1992-01-01

    For beam transfer from the KEK-PS Linac to the Booster synchrotron ring and from the Booster to the Main ring, many pulse magnets have been installed. It is very important for the machine operation to monitor the firing time, rising time and peak value of the pulsed magnet currents. It is also very important for magnet tuning to obtain good injection efficiency of the Booster and the Main ring, and to observe the last circulating bunched beam in the Booster as well as the first circulating in the Main. These magnet currents and beam intensity signals are digitized by a digital oscilloscope with signal multiplexers, and then shown on a graphic display screen of the console via a VME computer. (author)

  18. Effect of Catalytic Pyrolysis Conditions Using Pulse Current Heating Method on Pyrolysis Products of Wood Biomass

    Directory of Open Access Journals (Sweden)

    Sensho Honma

    2014-01-01

    Full Text Available The influence of catalysts on the compositions of char and pyrolysis oil obtained by pyrolysis of wood biomass with pulse current heating was studied. The effects of catalysts on product compositions were analyzed using GC-MS and TEM. The compositions of some aromatic compounds changed noticeably when using a metal oxide species as the catalyst. The coexistence or dissolution of amorphous carbon and iron oxide was observed in char pyrolyzed at 800°C with Fe3O4. Pyrolysis oil compositions changed remarkably when formed in the presence of a catalyst compared to that obtained from the uncatalyzed pyrolysis of wood meal. We observed a tendency toward an increase in the ratio of polyaromatic hydrocarbons in the pyrolysis oil composition after catalytic pyrolysis at 800°C. Pyrolysis of biomass using pulse current heating and an adequate amount of catalyst is expected to yield a higher content of specific polyaromatic compounds.

  19. Nickel coating on high strength low alloy steel by pulse current deposition

    Science.gov (United States)

    Nigam, S.; Patel, S. K.; Mahapatra, S. S.; Sharma, N.; Ghosh, K. S.

    2015-02-01

    Nickel is a silvery-white metal mostly used to enhance the value, utility, and lifespan of industrial equipment and components by protecting them from corrosion. Nickel is commonly used in the chemical and food processing industries to prevent iron from contamination. Since the properties of nickel can be controlled and varied over broad ranges, nickel plating finds numerous applications in industries. In the present investigation, pulse current electro-deposition technique has been used to deposit nickel on a high strength low alloy (HSLA) steel substrate.Coating of nickel is confirmed by X-ray diffraction (XRD) and EDAX analysis. Optical microscopy and SEM is used to assess the coating characteristics. Electrochemical polarization study has been carried out to study the corrosion behaviour of nickel coating and the polarisation curves have revealed that current density used during pulse electro-deposition plays a vital role on characteristics of nickel coating.

  20. Effect of Catalytic Pyrolysis Conditions Using Pulse Current Heating Method on Pyrolysis Products of Wood Biomass

    Science.gov (United States)

    Honma, Sensho; Hata, Toshimitsu; Watanabe, Takashi

    2014-01-01

    The influence of catalysts on the compositions of char and pyrolysis oil obtained by pyrolysis of wood biomass with pulse current heating was studied. The effects of catalysts on product compositions were analyzed using GC-MS and TEM. The compositions of some aromatic compounds changed noticeably when using a metal oxide species as the catalyst. The coexistence or dissolution of amorphous carbon and iron oxide was observed in char pyrolyzed at 800°C with Fe3O4. Pyrolysis oil compositions changed remarkably when formed in the presence of a catalyst compared to that obtained from the uncatalyzed pyrolysis of wood meal. We observed a tendency toward an increase in the ratio of polyaromatic hydrocarbons in the pyrolysis oil composition after catalytic pyrolysis at 800°C. Pyrolysis of biomass using pulse current heating and an adequate amount of catalyst is expected to yield a higher content of specific polyaromatic compounds. PMID:25614894

  1. The effect of applied electric field on pulsed radio frequency and pulsed direct current plasma jet array

    International Nuclear Information System (INIS)

    Hu, J. T.; Liu, X. Y.; Liu, J. H.; Xiong, Z. L.; Liu, D. W.; Lu, X. P.; Iza, F.; Kong, M. G.

    2012-01-01

    Here we compare the plasma plume propagation characteristics of a 3-channel pulsed RF plasma jet array and those of the same device operated by a pulsed dc source. For the pulsed-RF jet array, numerous long life time ions and metastables accumulated in the plasma channel make the plasma plume respond quickly to applied electric field. Its structure similar as “plasma bullet” is an anode glow indeed. For the pulsed dc plasma jet array, the strong electric field in the vicinity of the tube is the reason for the growing plasma bullet in the launching period. The repulsive forces between the growing plasma bullets result in the divergence of the pulsed dc plasma jet array. Finally, the comparison of 309 nm and 777 nm emissions between these two jet arrays suggests the high chemical activity of pulsed RF plasma jet array.

  2. Primary intrathoracic biphasic synovial sarcoma.

    Science.gov (United States)

    Tezcan, Yilmaz; Koc, Mehmet; Kocak, Husnu; Kaya, Yusuf

    2012-05-01

    Synovial sarcomas are most frequently observed in the extremities. Although synovial sarcomas are the third most common histological type of soft-tissue sarcomas of the extremities, primary mediastinal synovial sarcoma is extremely rare. Monophasic synovial sarcoma is the most commonly observed subtype. whereas the biphasic subtype is less common. We present our case which was diagnosed as biphasic synovial sarcoma located in the anterior mediastinum, which is considered to be a rare entity. The patient underwent surgical resection together with multimodal adjuvant radiotherapy and chemotherapy.

  3. Corrosion behaviour of zinc deposits obtained under pulse current electrodeposition: Effects of coumarin as additive

    International Nuclear Information System (INIS)

    Mouanga, M.; Ricq, L.; Douglade, J.; Bercot, P.

    2009-01-01

    The corrosion behaviour of zinc deposits obtained under pulsed current electrodeposition from an acidic chloride bath in the presence and absence of coumarin has been investigated. The effects of pulse peak current density (J p ) on the morphology of zinc deposits were studied by scanning electron microscopy. An increase in J p from 40 to 280 A dm -2 yields deposits with a finer grain size. The refinement of the grain size was more considerable in the presence of coumarin (J p = 280 A dm -2 ). The preferred orientation of zinc deposits was studied by X-ray diffraction. At J p = 40 A dm -2 , the preferred orientation of zinc deposits was (1 0 3) and changed to (0 0 2) at J p = 80 A dm -2 . An increase in J p to 280 A dm -2 did not change the preferred crystallographic orientations except for an increase in the peak intensity of the (0 0 2) plane. In the presence of coumarin, the preferred crystallographic orientations changed at J p = 280 A dm -2 from the (0 0 2) plane to the (1 0 3) plane. The corrosion behaviour was investigated in an aerated 3.5% NaCl solution; the anodic polarization and electrochemical impedance spectroscopy curves were performed. The corrosion resistance of zinc deposits was improved by increasing the pulse peak current density (J p ); whereas, the presence of coumarin did not improve the corrosion resistance

  4. Numerical simulation and experiment of high-intensity current pulsed impact on the structure body

    International Nuclear Information System (INIS)

    Li Mintang; Yan Ping; Yuan Weiqun; Sun Yaohong; Sun Lianhua; Zhou Yuan; Liu Chuanpu

    2010-01-01

    To better understand the characteristics of the impulse force formed by pulse current of electromagnetic rail propulsion system, and to explore effective ways to improve the support structure of rails, a set of impulse force test system was designed, and the work-related test situation was numerically simulated. Several impulse force waveforms formed by different pulse current waveforms were achieved by using an armature as a source of impulse force in this test system, and two curves of waveform were comparatively analyzed. The armature existing in the environment of coupling fields including electric field and magnetic field and force field was carried out numerical calculation by using the software of ANSYS, and the coupling force field was emphatically analyzed to calculate the electromagnetic driving force and the electromagnetic clamping force acting on the armature, and the structure stress and deformation was also analyzed. The results showed that the curves of electromagnetic driving force computed by numerical simulation and the curves of impulse force obtained by experiment were basically the same, and the value of peak points' error was increasing along with the increase of pulse current, but the curves still showed some common characteristics. This verified that the test method we used in this paper was proper to capture the impulse force, and the method of calculation was also feasible and effective. (authors)

  5. Operation of a load current multiplier on a nanosecond mega-ampere pulse forming line generator

    Directory of Open Access Journals (Sweden)

    A. S. Chuvatin

    2010-01-01

    Full Text Available We investigate the operation of a load current multiplier (LCM on a pulse-forming-line nanosecond pulse-power generator. Potential benefits of using the LCM technique on such generators are studied analytically for a simplified case. A concrete LCM design on the Zebra accelerator (1.9 Ohm, ∼1  MA, 100 ns is described. This design is demonstrated experimentally with high-voltage power pulses having a rise time of dozens of nanoseconds. Higher currents and magnetic energies were observed in constant-inductance solid-state loads when a better generator-to-load energy coupling was achieved. The load current on Zebra was increased from the nominal 0.8–0.9 MA up to about 1.6 MA. This result was obtained without modifying the generator energetics or architecture and it is in good agreement with the presented numerical simulations. Validation of the LCM technique at a nanosecond time scale is of importance for the high-energy-density physics research.

  6. Regression analysis of pulsed eddy current signals for inspection of steam generator tube support structures

    International Nuclear Information System (INIS)

    Buck, J.; Underhill, P.R.; Mokros, S.G.; Morelli, J.; Krause, T.W.; Babbar, V.K.; Lepine, B.

    2015-01-01

    Nuclear steam generator (SG) support structure degradation and fouling can result in damage to SG tubes and loss of SG efficiency. Conventional eddy current technology is extensively used to detect cracks, frets at supports and other flaws, but has limited capabilities in the presence of multiple degradation modes or fouling. Pulsed eddy current (PEC) combined with principal components analysis (PCA) and multiple linear regression models was examined for the inspection of support structure degradation and SG tube off-centering with the goal of extending results to include additional degradation modes. (author)

  7. Efficiency of pulse high-current generator energy transfer into plasma liner energy

    Science.gov (United States)

    Oreshkin, V. I.

    2013-08-01

    The efficiency of capacitor-bank energy transfer from a high-current pulse generator into kinetic energy of a plasma liner has been analyzed. The analysis was performed using a model including the circuit equations and equations of the cylindrical shell motion. High efficiency of the energy transfer into kinetic energy of the liner is shown to be achieved only by a low-inductance generator. We considered an "ideal" liner load in which the load current is close to zero in the final of the shell compression. This load provides a high (up to 80%) efficiency of energy transfer and higher stability when compressing the liner.

  8. Resistive states created in superconducting NbTiN filaments by an electrical current pulse

    Directory of Open Access Journals (Sweden)

    K. Harrabi

    2015-03-01

    Full Text Available We have observed as a function of the time the appearance of the voltage caused by a larger-than-critical (I > Ic step-pulse of current in narrow NbTiN strips at 4.2 K. Different current intensities produced either phase-slip centres characterized by a voltage saturating with the time, or ever expanding hot spots. These dissipative structures occur after a measurable delay time, whose dependence upon the ratio I/Ic can be analysed through a Ginzburg-Landau theory to yield a unique adjustable time constant.

  9. Energy efficiency of electric pulse installation based on a high-current plasma accelerator

    Directory of Open Access Journals (Sweden)

    Shanenkov I.I.

    2014-01-01

    Full Text Available The energy efficiency of electric pulse installation based on a high-current plasma accelerator was investigated. A series of experiments with different central electrodes was carried out. The system based on carbon electrodes has a greater value of the charge energy conversion into the energy of arc discharge and the less discharge current level in comparison with other electrode systems. The power consumption value for producing 1 gram of powdered product was estimated and it was found this value is comparable to the work of the LED light bulb for 1 hour.

  10. Surface modification of polyacrylonitrile co-polymer membranes using pulsed direct current nitrogen plasma

    International Nuclear Information System (INIS)

    Pal, Dipankar; Neogi, Sudarsan; De, Sirshendu

    2015-01-01

    Low temperature plasma treatment using pulsed direct current discharge of nitrogen gas was employed to enhance hydrophilicity of the polyacrylonitrile co-polymer membranes. The membranes were characterized in terms of morphology, structure, hydrophilicity, and membrane performance. Properties and functional groups on the surface of polyacrylonitrile co-polymer membranes were investigated by contact angle, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Effects of plasma conditions, namely, pulsed voltage, duty cycle and treatment time on increase in membrane hydrophilicity were studied. Permeability of treated membrane was increased by 47% and it was retained up to 70 days. Surface etching due to plasma treatment was confirmed by weight loss of the treated membranes. Due to surface etching, average pore size increased and rejection of 200 kDa polyethylene glycol decreased to about 70% for the treated membrane. Oxygen and nitrogen functional groups were responsible for surface hydrophilicity. - Highlights: • Surface modification of polyacrylonitrile co-polymer membranes by pulsed direct current nitrogen plasma • Hydrophilic functional groups incorporated on the membrane surface • Significant enhancement of the permeability and wettability of the membranes • Water contact angle increased with storage time and finally stabilized.

  11. Surface modification of polyacrylonitrile co-polymer membranes using pulsed direct current nitrogen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Pal, Dipankar; Neogi, Sudarsan; De, Sirshendu, E-mail: sde@che.iitkgp.ernet.in

    2015-12-31

    Low temperature plasma treatment using pulsed direct current discharge of nitrogen gas was employed to enhance hydrophilicity of the polyacrylonitrile co-polymer membranes. The membranes were characterized in terms of morphology, structure, hydrophilicity, and membrane performance. Properties and functional groups on the surface of polyacrylonitrile co-polymer membranes were investigated by contact angle, scanning electron microscopy, Fourier transform infrared and X-ray photoelectron spectroscopy. Effects of plasma conditions, namely, pulsed voltage, duty cycle and treatment time on increase in membrane hydrophilicity were studied. Permeability of treated membrane was increased by 47% and it was retained up to 70 days. Surface etching due to plasma treatment was confirmed by weight loss of the treated membranes. Due to surface etching, average pore size increased and rejection of 200 kDa polyethylene glycol decreased to about 70% for the treated membrane. Oxygen and nitrogen functional groups were responsible for surface hydrophilicity. - Highlights: • Surface modification of polyacrylonitrile co-polymer membranes by pulsed direct current nitrogen plasma • Hydrophilic functional groups incorporated on the membrane surface • Significant enhancement of the permeability and wettability of the membranes • Water contact angle increased with storage time and finally stabilized.

  12. Various categories of defects after surface alloying induced by high current pulsed electron beam irradiation

    International Nuclear Information System (INIS)

    Luo, Dian; Tang, Guangze; Ma, Xinxin; Gu, Le; Sun, Mingren; Wang, Liqin

    2015-01-01

    Highlights: • Four kinds of defects are found during surface alloying by high current electron beam. • Exploring the mechanism how these defects appear after irradiation. • Increasing pulsing cycles will help to get good surface quality. • Choosing proper energy density will increase surface quality. - Abstract: High current pulsed electron beam (HCPEB) is an attractive advanced materials processing method which could highly increase the mechanical properties and corrosion resistance. However, how to eliminate different kinds of defects during irradiation by HCPEB especially in condition of adding new elements is a challenging task. In the present research, the titanium and TaNb-TiW composite films was deposited on the carburizing steel (SAE9310 steel) by DC magnetron sputtering before irradiation. The process of surface alloying was induced by HCPEB with pulse duration of 2.5 μs and energy density ranging from 3 to 9 J/cm 2 . Investigation of the microstructure indicated that there were several forms of defects after irradiation, such as surface unwetting, surface eruption, micro-cracks and layering. How the defects formed was explained by the results of electron microscopy and energy dispersive spectroscopy. The results also revealed that proper energy density (∼6 J/cm 2 ) and multi-number of irradiation (≥50 times) contributed to high quality of alloyed layers after irradiation

  13. Manipulation of magnetic carriers for drug delivery using pulsed-current high T {sub c} superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yung [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)]. E-mail: yscha@anl.gov; Chen, Lihua [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824 (United States); Askew, Thomas [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Physics Department, Kalamazoo College, Kalamazoo, MI 49006 (United States); Veal, Boyd [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Hull, John [Energy Technology Division and Material Science Division, Building 335, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States)

    2007-04-15

    An innovative method of manipulating magnetic carriers is proposed, and its feasibility for drug delivery and therapy is demonstrated experimentally. The proposed method employs pulsed-field solenoid coils with high-critical- temperature (T {sub c}) superconductor inserts. Pulsed current is used to magnetize and de-magnetize the superconductor insert. The proposed method was demonstrated to be able to (1) move magnetic particles, ranging in size from a few millimeters to 10 {mu}m, with strong enough forces over a substantial distance, (2) hold the particles at a designated position as long as needed, and (3) reverse the processes and retrieve the particles. We further demonstrated that magnetic particles can be manipulated in a stationary environment, in water flow, and in simulated blood (water/glycerol mixture) flow.

  14. Mechanism for negative corona current pulse in CO{sub 2}-SF{sub 6} mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Zahoranova, A [Faculty of Mathematics, Physics, and Informatics, Institute of Physics, Comenius University, Mlynska dolina F2, 842 48 Bratislava (Slovakia); Kudelcik, J [Faculty of Natural Sciences, University of Zilina, Hurbanova 15, Zilina (Slovakia); Simor, M [Faculty of Mathematics, Physics, and Informatics, Institute of Physics, Comenius University, Mlynska dolina F2, 842 48 Bratislava (Slovakia); Cernak, M [Faculty of Mathematics, Physics, and Informatics, Institute of Physics, Comenius University, Mlynska dolina F2, 842 48 Bratislava (Slovakia)

    2003-04-21

    Current waveforms of first negative corona pulses have been measured in CO{sub 2}-SF{sub 6} mixtures over a pressure range extending from 6.65 to 50 kPa and various overvoltages. Effects of changing cathode secondary electron emission were studied using a copper cathode coated by CuI and graphite. For a given set of experimental conditions it is concluded that in the mixtures containing up to 30% of SF{sub 6} the negative corona pulse is associated with the formation of a cathode-directed streamer-like ionizing wave in the immediate vicinity of the cathode. This is in contrast to the discharge behaviour in air-SF{sub 6} and N{sub 2}-SF{sub 6} mixtures, where in similar conditions the discharge develops according to a multi-avalanche Townsend mechanism. (rapid communication)

  15. Mechanism for negative corona current pulse in CO sub 2 -SF sub 6 mixtures

    CERN Document Server

    Zahoranova, A; Simor, M; Cernak, M

    2003-01-01

    Current waveforms of first negative corona pulses have been measured in CO sub 2 -SF sub 6 mixtures over a pressure range extending from 6.65 to 50 kPa and various overvoltages. Effects of changing cathode secondary electron emission were studied using a copper cathode coated by CuI and graphite. For a given set of experimental conditions it is concluded that in the mixtures containing up to 30% of SF sub 6 the negative corona pulse is associated with the formation of a cathode-directed streamer-like ionizing wave in the immediate vicinity of the cathode. This is in contrast to the discharge behaviour in air-SF sub 6 and N sub 2 -SF sub 6 mixtures, where in similar conditions the discharge develops according to a multi-avalanche Townsend mechanism. (rapid communication)

  16. Resonant amplification of magnetic domain-wall motion by a train of current pulses.

    Science.gov (United States)

    Thomas, Luc; Hayashi, Masamitsu; Jiang, Xin; Moriya, Rai; Rettner, Charles; Parkin, Stuart

    2007-03-16

    The current-induced motion of magnetic domain walls confined to nanostructures is of interest for applications in magnetoelectronic devices in which the domain wall serves as the logic gate or memory element. The injection of spin-polarized current below a threshold value through a domain wall confined to a pinning potential results in its precessional motion within the potential well. We show that by using a short train of current pulses, whose length and spacing are tuned to this precession frequency, the domain wall's oscillations can be resonantly amplified. This makes possible the motion of domain walls with much reduced currents, more than five times smaller than in the absence of resonant amplification.

  17. Electrically Elicited Muscle Torque: Comparison Between 2500-Hz Burst-Modulated Alternating Current and Monophasic Pulsed Current.

    Science.gov (United States)

    Scott, Wayne; Adams, Cheryl; Cyr, Shantelle; Hanscom, Brianna; Hill, Kevin; Lawson, Jeffrey; Ziegenbein, Colin

    2015-12-01

    Single-blind, block-randomization crossover design. To compare the knee extensor muscle torque production elicited with 2500-Hz burst-modulated alternating current (BMAC) and with a monophasic pulsed current (MPC) at the maximum tolerated stimulation intensity. Neuromuscular electrical stimulation (NMES) is often used for strengthening the quadriceps following knee surgery. Strength gains are dependent on muscle torque production, which is primarily limited by discomfort. Burst-modulated alternating current stimulation is a clinically popular waveform for NMES. Prior research has established that MPC with a relatively long pulse duration is effective for high muscle torque production. Participants in this study were 20 adults with no history of knee injury. A crossover design was used to randomize the order in which each participant's dominant or nondominant lower extremity received NMES and the waveform (MPC or BMAC) this limb received. Stimulation intensity was incrementally increased until participants reached their maximum tolerance. The torque produced was converted to a percentage of each participant's maximum volitional isometric contraction of the respective limb. A general linear model for a 2-treatment, 2-period crossover design was utilized to analyze the results. The mean ± SD electrically induced percent maximum volitional isometric contraction at maximal participant tolerance was 49.5% ± 19.6% for MPC and 29.8% ± 12.4% for BMAC. This difference was statistically significant (P = .002) after accounting for treatment order and limb, which had no effect on torque production. Neuromuscular stimulation using MPC may be more efficacious than using BMAC to achieve a high torque output in patients with quadriceps weakness.

  18. Change of the pulsed eddy Current signals by the variation of the thickness of an aluminum specimen

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Ki; Shu, Dong Man [Center of Environment and Safty Measurement, Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of); Lee, Seung Seok [R and D Center, RAYNAR Co,. Ltd, Daejeon (Korea, Republic of)

    2004-11-15

    Eddy current testing has been used for detecting the defect like fatigue crack in the conductive materials such as aluminum. The conventional eddy current testing uses a sinusoidal signal with very narrow frequency bandwidth. Whereas, the pulsed eddy current method uses a pulse signal with a broad frequency bandwidth. This allows multi-frequency eddy current testing, and the penetration depth is greater than that of the conventional eddy current testing. In this work, the pulsed eddy current instrument was developed for evaluating the metal loss. The developed instrument was consist of the pulse generator generating the square pulse of maximum 40 V, the amplifier controlled to 52 dB, the A/D converter of 16 bit 20 MHz, and the industrial personal computer for operating with Windows program. And, the probe for the pulsed eddy current was designed as the pancake type in which the sensing coil was located in the driving coil. The peak voltage did not linearly increase with the voltage of the step pulse. For the driving coil with inductance of 670 H, the peak voltage linearly increased with the step pulse voltage to 30 V. But, for the other driving coils with the inductance of 1.7 mH, 2.7 mH, 3.6 mH, 22 mH, the peak voltage linearly increased with the step pulse voltage to 20 V. The output signals of the sensing coil rapidly increased when the step pulse driving voltage was off, and the latter part of the sensing coil output voltage exponentially decreased with a time. The decrement value of tile output signals of sensing coil increased with the thickness of the aluminum test piece.

  19. Elemental redistribution in coloured films on SUS304 stainless steel produced by current pulse method

    International Nuclear Information System (INIS)

    Lin, C.J.; Duh, J.G.

    1996-01-01

    Coloured films are deposited on an SUS304 substrate by the square wave current pulse method in a 2.5 M CrO 3 + 5 M H 2 SO 4 solution at 75 C. The absolute ratio of anodic to cathodic charge density and the corresponding final value of cathodic potential provide an easy and appropriate approach to the control of colour in the current pulse colouring method. This is proved in this study for a frequency region lower than 1 Hz. The corresponding cathodic potential increases with increasing dwell time in the negative applied current region and is related to the colour tone of the deposited film. The total time required to obtain the same thickness of coloured film is shorter at lower frequency than at higher frequency, which takes more time to charge the double layer. The thickness of the coloured films is determined by both Auger electron spectroscopy (AES) and secondary ion mass spectrometry (SIMS) depth profiling and is of submicron order. The film thickness is proportional to the introduced total charge per unit area in the current pulse colouring process. CrO + and FeO + ions are observed in the coloured films and their concentrations increase as the colouring time is increased. The Fe concentration in the coloured films is lower than that in the substrate and decreases with the colouring time. It is the iron species that first becomes involved in the anodic reaction and the spinel oxide structure of iron and chromium is present in the coloured films. (orig.)

  20. Characterization of a high-power/current pulsed magnetized arc discharge

    Science.gov (United States)

    Zielinski, J. J.; van der Meiden, H. J.; Morgan, T. W.; Schram, D. C.; De Temmerman, G.

    2012-12-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 µF) is parallel-coupled to the current regulated power supply. The current is transiently increased from its stationary value (200 A) up to 14.5 kA in 650 µs. The discharge power is thus raised from 18 kW to 6.5 MW, corresponding to a power density of up to 1.7 × 1012 W m-3-102 times higher than in the dc mode (200 A). The plasma parameters are measured by Thomson scattering ˜4 cm downstream of the nozzle. The electron temperature and density vary from ˜2.6 eV and 7 × 1020 m-3 in dc and up to 15 eV and 80 × 1020 m-3 during the pulse. A saturation of the electron density with increasing current is observed while the temperature increases monotonically. Time-resolved voltage/current measurements of the arc are used to explain the role of the magnetic field and the evolution of the temperature.

  1. Effects of Russian current and low-frequency pulsed current on discomfort level and current amplitude at 10% maximal knee extensor torque.

    Science.gov (United States)

    Vaz, Marco Aurélio; Aragão, Fernando Amâncio; Boschi, Émerson S; Fortuna, Rafael; Melo, Mônica de Oliveira

    2012-11-01

    Low-frequency pulsed current (LFPC) and Russian current (RC), a type of kilohertz-frequency alternating current, have been frequently used for muscle strengthening in rehabilitation programs. Despite the popularity of these current types, it is unclear which is most effectively able to generate a similar submaximal torque with minimal discomfort and current amplitude. To compare discomfort and current amplitude between LFPC and RC to achieve a knee extensor torque of 10% of the maximal isometric voluntary contraction (MIVC). Twenty-two healthy subjects were subjected to three electrically elicited knee extensor submaximal contractions (10% MIVC) that were sustained for 10 seconds. The current amplitude required to achieve 10% MIVC and subjective discomfort were assessed directly by the electrical stimulator and with the Visual Analogue Pain Scale, respectively. A paired t-test was used to determine differences between the electrical currents (α = 0.05). LFPC required significantly lower current amplitude (15%) and a lower discomfort level (50%) to achieve 10% of MIVC compared to RC. LFPC current seems to be more effective than RC with respect to discomfort level and current amplitude to produce 10% of MIVC.

  2. Surface Crack Detection for Carbon Fiber Reinforced Plastic Materials Using Pulsed Eddy Current Based on Rectangular Differential Probe

    Directory of Open Access Journals (Sweden)

    Jialong Wu

    2014-01-01

    Full Text Available Aiming at the surface defect inspection of carbon fiber reinforced composite, the differential and the direct measurement finite element simulation models of pulsed eddy current flaw detection were built. The principle of differential pulsed eddy current detection was analyzed and the sensitivity of defect detection was compared through two kinds of measurements. The validity of simulation results was demonstrated by experiments. The simulation and experimental results show that the pulsed eddy current detection method based on rectangular differential probe can effectively improve the sensitivity of surface defect detection of carbon fiber reinforced composite material.

  3. Progress on the biphase turbine at Cerro Prieto

    Energy Technology Data Exchange (ETDEWEB)

    Cerini, D.; Hays, L.; Studhalter, W. [Douglas Energy Company, Placentia, CA (United States)

    1997-12-31

    The status of a Biphase turbine power plant being installed at the Cerro Prieto geothermal field is presented. The major modules for the power plant are completed except for a back pressure steam turbine. The power plant will be started in April 1997 with the Biphase turbine alone followed by the addition of the steam turbine module two months later. The current power plant performance level is 2780 kWe due to a decline in the well. An increase in power output to 4060 kWe by adding the flow from another well is planned. The addition of five Biphase power plants with a total power output of 21.2 megawatts is described.

  4. Current pulses sampling by flash analog/digital converters and evaluation of the method

    International Nuclear Information System (INIS)

    Jolly, A.

    1987-06-01

    The electronic equipment of the 4π steradian Diogene detector uses the following principle: an analog and time controlled integration is applied to the signal. Since this integration remains active during a fixed time, double track resolution perfomance is limited. The probability of piled up pulses increases with the multiplicity of events detected in drift chambers. This induces wrong values for informations the current division method gives. To allow the separation and the treatment of each pulse, the envelope over a wellknown baseline must be acquired. So we develop a sampling system around Flash Analog/Digital Converters. First, we calculate the standard deviation in the measurement of the Z position along sensitive wires in the detector, as a result of digitization error. Calculations allow us to choose parameters and the number of coding bits we need in 3 possible coding shemes. We show that a cascade, (7 bits) built with 2 Flash converters in front of which a logarithmic transfer fonction is inserted, makes amplitude dynamic compatible with Z position measure. Then, we propose some solutions to realize the prototype, to resolve electronic problems concerning synchronism and high frequencies requirements. At last, a test sequency is performed to characterize the quality obtained. Clock and logic circuits parasitic signals influence, differential linearity and typical pulses reproducibility determine the highest suitable sampling frequency, equal to 83 MHz [fr

  5. Laminar iridium coating produced by pulse current electrodeposition from chloride molten salt

    Science.gov (United States)

    Zhu, Li'an; Bai, Shuxin; Zhang, Hong; Ye, Yicong

    2013-10-01

    Due to the unique physical and chemical properties, Iridium (Ir) is one of the most promising oxidation-resistant coatings for refractory materials above 1800 °C in aerospace field. However, the Ir coatings prepared by traditional methods are composed of columnar grains throughout the coating thickness. The columnar structure of the coating is considered to do harm to its oxidation resistance. The laminar Ir coating is expected to have a better high-temperature oxidation resistance than the columnar Ir coating does. The pulse current electrodeposition, with three independent parameters: average current density (Jm), duty cycle (R) and pulse frequency (f), is considered to be a promising method to fabricate layered Ir coating. In this study, laminar Ir coatings were prepared by pulse current electrodeposition in chloride molten salt. The morphology, roughness and texture of the coatings were determined by scanning electron microscope (SEM), profilometer and X-ray diffraction (XRD), respectively. The results showed that the laminar Ir coatings were composed of a nucleation layer with columnar structure and a growth layer with laminar structure. The top surfaces of the laminar Ir coatings consisted of cauliflower-like aggregates containing many fine grains, which were separated by deep grooves. The laminar Ir coating produced at the deposition condition of 20 mA/cm2 (Jm), 10% (R) and 6 Hz (f) was quite smooth (Ra 1.01 ± 0.09 μm) with extremely high degree of preferred orientation of , and its laminar structure was well developed with clear boundaries and uniform thickness of sub-layers.

  6. A frequency domain approach to analyzing passive battery-ultracapacitor hybrids supplying periodic pulsed current loads

    International Nuclear Information System (INIS)

    Kuperman, Alon; Aharon, Ilan; Kara, Avi; Malki, Shalev

    2011-01-01

    Highlights: → Passive battery-ultracapacitor hybrids are examined. → Frequency domain analysis is employed. → The ultracapacitor branch operates as a low-pass filter for the battery. → The battery supplies the average load demand. → Design requirements are discussed. - Abstract: A Fourier-based analysis of passive battery-ultracapacitor hybrid sources is introduced in the manuscript. The approach is first introduced for a general load, and then is followed by a study for a case of periodic pulsed current load. It is shown that the ultracapacitor branch is perceived by the battery as a low-pass filter, which absorbs the majority of the high frequency harmonic current and letting the battery to supply the average load demand in addition to the small part of dynamic current. Design requirements influence on the ultracapacitor capacitance and internal resistance choice are quantitatively discussed. The theory is enforced by simulation and experimental results, showing an excellent agreement.

  7. Spectral and temporal characteristics of target current and electromagnetic pulse induced by nanosecond laser ablation

    Science.gov (United States)

    Krása, J.; De Marco, M.; Cikhardt, J.; Pfeifer, M.; Velyhan, A.; Klír, D.; Řezáč, K.; Limpouch, J.; Krouský, E.; Dostál, J.; Ullschmied, J.; Dudžák, R.

    2017-06-01

    The current balancing the target charging and the emission of transient electromagnetic pulses (EMP) driven by the interaction of a focused 1.315 μm iodine 300 ps PALS laser with metallic and plastic targets were measured with the use of inductive probes. It is experimentally proven that the duration of return target currents and EMPs is much longer than the duration of laser-target interaction. The laser-produced plasma is active after the laser-target interaction. During this phase, the target acts as a virtual cathode and the plasma-target interface expands. A double exponential function is used in order to obtain the temporal characteristics of EMP. The rise time of EMPs fluctuates in the range up to a few tens of nanoseconds. Frequency spectra of EMP and target currents are modified by resonant frequencies of the interaction chamber.

  8. Electrocatalysis of the hydrogen evolution reaction by rhenium oxides electrodeposited by pulsed-current

    International Nuclear Information System (INIS)

    Vargas-Uscategui, Alejandro; Mosquera, Edgar; Chornik, Boris; Cifuentes, Luis

    2015-01-01

    Highlights: • Rhenium oxides were produced by means of pulsed current electrodeposition over ITO. • The electrocatalytic behavior of rhenium oxides electrodeposited over ITO was studied. • Electrodeposited rhenium oxides showed electrocatalytic behavior increasing the rate of the hydrogen evolution reaction. • The electrocatalysis behavior was explained considering the relative abundance of Re species on the surface of the electrodeposited material. - Abstract: Rhenium oxides are materials of interest for applications in the catalysis of reactions such as those occurring in fuel cells and photoelectrochemical cells. This research work was devoted to the production of rhenium oxide by means of pulsed current electrodeposition for the electrocatalysis of the hydrogen evolution reaction (HER). Rhenium oxides were electrodeposited over a transparent conductive oxide substrate (Indium Tin-doped Oxide – ITO) in an alkaline aqueous electrolyte. The electrodeposition process allowed the production of rhenium oxides islands (200–600 nm) with the presence of three oxidized rhenium species: Re IV associated to ReO 2 , Re VI associated to ReO 3 and Re VII associated to H(ReO 4 )H 2 O. Electrodeposited rhenium oxides showed electrocatalytic behavior over the HER and an increase of one order of magnitude of the exchange current density was observed compared to the reaction taking place on the bare substrate. The electrocatalytic behavior varied with the morphology and relative abundance of oxidized rhenium species in the electrodeposits. Finally, two mechanisms of electrocatalysis were proposed to explain experimental results.

  9. Description of current pulses induced by heavy ions in silicon detectors (II)

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette Cedex (France); Parlog, M. [LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); National Institute for Physics and Nuclear Engineering, RO-76900 Bucharest-Magurele (Romania); Borderie, B., E-mail: borderie@ipno.in2p3.fr [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Lavergne, L. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Le Neindre, N. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); Rivet, M.F.; Barbey, S. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Bougault, R. [LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); Chabot, M. [Inst. de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); Chbihi, A. [GANIL (DSM-CEA/CNRS/IN2P3), F-14076 Caen Cedex (France); Cussol, D. [LPC, CNRS/IN2P3, ENSICAEN, Univ. de Caen, F-14050 Caen Cedex (France); Oliveira Santos, F. de [GANIL (DSM-CEA/CNRS/IN2P3), F-14076 Caen Cedex (France); Edelbruck, P. [Inst. de Physique Nucleaire, CNRS/IN2P3, Univ. Paris-Sud 11, F-91406 Orsay Cedex (France); Frankland, J.D. [GANIL (DSM-CEA/CNRS/IN2P3), F-14076 Caen Cedex (France); Galichet, E. [Inst. de Physique Nucleaire, CNRS/IN2P3, Univ. Paris-Sud 11, F-91406 Orsay Cedex (France); Conservatoire National des Arts et Metier, F-75141 Paris Cedex 03 (France); Guinet, D.; Lautesse, Ph. [Inst. de Physique Nucleaire, CNRS/IN2P3, Univ.e Claude Bernard Lyon I, F-69622 Villeurbanne Cedex (France); Lopez, O. [LPC, CNRS/IN2P3, ENSICAEN, Univ. de Caen, F-14050 Caen Cedex (France)

    2011-06-21

    Current pulses induced in a silicon detector by 10 different heavy ion species at known energies around 10 A MeV have been sampled in time at high frequency. Their individual average shapes are quite well reproduced by a fit procedure based on our recent charge carrier collection treatment which considers the progressive extraction of the electrons and holes from the high carrier density zone along the ionizing particle track. This region is assumed to present a supplementary dielectric polarization and consequently a disturbed electric field. The influence of the nature of the heavy ion on the values of the three fit parameters is analyzed.

  10. Spectral and temporal characteristics of target current and electromagnetic pulse induced by nanosecond laser ablation

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; De Marco, Massimo; Cikhardt, Jakub; Pfeifer, Miroslav; Velyhan, Andriy; Klír, Daniel; Řezáč, Karel; Limpouch, J.; Krouský, Eduard; Dostál, Jan; Ullschmied, Jiří; Dudžák, Roman

    2017-01-01

    Roč. 59, č. 6 (2017), 1-8, č. článku 065007. ISSN 0741-3335 R&D Projects: GA MŠk EF15_008/0000162; GA ČR GA16-07036S EU Projects: European Commission(XE) 654148 - LASERLAB-EUROPE Grant - others:ELI Beamlines(XE) CZ.02.1.01/0.0/0.0/15_008/0000162 Institutional support: RVO:68378271 ; RVO:61389021 Keywords : laser-produced plasma * target current * electromagnetic pulse Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.392, year: 2016

  11. Evaluation of a Unique Defibrillation Unit with Dual-Vector Biphasic Waveform Capabilities: Towards a Miniaturized Defibrillator.

    Science.gov (United States)

    Okamura, Hideo; Desimone, Christopher V; Killu, Ammar M; Gilles, Emily J; Tri, Jason; Asirvatham, Roshini; Ladewig, Dejae J; Suddendorf, Scott H; Powers, Joanne M; Wood-Wentz, Christina M; Gray, Peter D; Raymond, Douglas M; Savage, Shelley J; Savage, Walter T; Bruce, Charles J; Asirvatham, Samuel J; Friedman, Paul A

    2017-02-01

    Automated external defibrillators can provide life-saving therapies to treat ventricular fibrillation. We developed a prototype unit that can deliver a unique shock waveform produced by four independent capacitors that is delivered through two shock vectors, with the rationale of providing more robust shock pathways during emergent defibrillation. We describe the initial testing and feasibility of this unique defibrillation unit, features of which may enable downsizing of current defibrillator devices. We tested our defibrillation unit in four large animal models (two canine and two swine) under general anesthesia. Experimental defibrillation thresholds (DFT) were obtained by delivery of a unique waveform shock pulse via a dual-vector pathway with four defibrillation pads (placed across the chest). DFTs were measured and compared with those of a commercially available biphasic defibrillator (Zoll M series, Zoll Medical, Chelmsford, MA, USA) tested in two different vectors. Shocks were delivered after 10 seconds of stable ventricular fibrillation and the output characteristics and shock outcome recorded. Each defibrillation series used a step-down to failure protocol to define the defibrillation threshold. A total of 96 shocks were delivered during ventricular fibrillation in four large animals. In comparison to the Zoll M series, which delivered a single-vector, biphasic shock, the energy required for successful defibrillation using the unique dual-vector biphasic waveform did not differ significantly (P = 0.65). Our early findings support the feasibility of a unique external defibrillation unit using a dual-vector biphasic waveform approach. This warrants further study to leverage this unique concept and work toward a miniaturized, portable shock delivery system. © 2016 Wiley Periodicals, Inc.

  12. [Treatment of venous ulcers with low frequency pulsed current (Dermapulse): effects on cutaneous microcirculation].

    Science.gov (United States)

    Jünger, M; Zuder, D; Steins, A; Hahn, M; Klyscz, T

    1997-12-01

    Chronic venous insufficiency (CVI) is characterised by stage-dependent microangiopathy. With increasing severity there is a decrease in the number of skin capillaries and the oxygen partial pressure. The cutaneous vascular reserve, which is measured by laser-doppler fluxmetry, is reduced. Cutaneous microangiopathy is one of the main causes of the trophic disturbances associated with CVI. Low frequency pulsed current improves cutaneous microcirculation and thus nutrition as well as accelerating the formation of granulation tissue. In a open prospective pilot study, 15 patients suffering from CVI with persistent leg ulcers were treated with low frequency pulsed current (Dermapulse), which is thought to improve particularly the tissue microcirculation. The average age of the patients was 70.3 years and the average duration of ulceration was 79.1 months. The patients were treated over a period of 38 days. With this treatment, 2 ulcers healed completely and 13 showed a reduction of size of on average 63%. Capillary density increased by 43.5%, while transcutaneous oxygen partial pressure increased by 82.4%. Electrostimulation is a treatment with few or no side effects.

  13. Blocking and guiding adult sea lamprey with pulsed direct current from vertical electrodes

    Science.gov (United States)

    Johnson, Nicholas S.; Thompson, Henry T.; Holbrook, Christopher M.; Tix, John A.

    2014-01-01

    Controlling the invasion front of aquatic nuisance species is of high importance to resource managers. We tested the hypothesis that adult sea lamprey (Petromyzon marinus), a destructive invasive species in the Laurentian Great Lakes, would exhibit behavioral avoidance to dual-frequency pulsed direct current generated by vertical electrodes and that the electric field would not injure or kill sea lamprey or non-target fish. Laboratory and in-stream experiments demonstrated that the electric field blocked sea lamprey migration and directed sea lamprey into traps. Rainbow trout (Oncorhynchus mykiss) and white sucker (Catostomus commersoni), species that migrate sympatrically with sea lamprey, avoided the electric field and had minimal injuries when subjected to it. Vertical electrodes are advantageous for fish guidance because (1) the electric field produced varies minimally with depth, (2) the electric field is not grounded, reducing power consumption to where portable and remote deployments powered by solar, wind, hydro, or a small generator are feasible, and (3) vertical electrodes can be quickly deployed without significant stream modification allowing rapid responses to new invasions. Similar dual-frequency pulsed direct current fields produced from vertical electrodes may be advantageous for blocking or trapping other invasive fish or for guiding valued fish around dams.

  14. Effects of Coil Diameter in Thickness Measurement Using Pulsed Eddy Current Non-destructive Testing

    Science.gov (United States)

    Nisa Azaman, Khairun; Sophian, Ali; Nafiah, Faris

    2017-11-01

    Non-destructive testing (NDT) techniques are used in industry to evaluate the properties of a material, component or structure without causing any permanent damage. Among the techniques, pulsed eddy current (PEC) NDT is regarded as a new technique where a broadband pulse excitation is used, as opposed to single frequencies employed in conventional eddy current NDT. In this study, a 2D axisymmetric electromagnetic model of a PEC probe has been developed and it has been used to study the effects of the excitation coil diameter on the performance of PEC probes in sample thickness measurement. A PEC system has also been built to validate the model. Aluminium plates are used as the sample and they can be stacked up to replicate thickness from 1 mm to 10 mm. The results show that there is a very good correlation between the simulation and experimental results, with an average error of less than 10%. The results also suggest that the larger the diameter of the excitation coil, the deeper the penetration and therefore the larger the thickness measurement range. It has also been shown that although the larger diameters have deeper penetration, the smallest diameter has the highest sensitivity if normalization is not used. These conclusions indicate that coil diameter is an important parameter in a PEC probe design for thickness measurement applications.

  15. High voltage pulsed current in collagen realignment, synthesis, and angiogenesis after Achilles tendon partial rupture

    Directory of Open Access Journals (Sweden)

    Érika P. Rampazo

    2016-01-01

    Full Text Available ABSTRACT Objective To verify the efficacy of high voltage pulsed current in collagen realignment and synthesis and in angiogenesis after the partial rupturing of the Achilles tendon in rats. Method Forty male Wistar rats were randomized into four groups of 10 animals each: sham, cathodic stimulation, anodic stimulation, and alternating stimulation. Their Achilles tendons were submitted to direct trauma by a free-falling metal bar. Then, the treatment was administered for six consecutive days after the injury. In the simulation group, the electrodes were positioned on the animal, but the device remained off for 30 minutes. The other groups used a frequency of 120 pps, sensory threshold, and the corresponding polarity. On the seventh day, the tendons were removed and sent for histological slide preparation for birefringence and Picrosirius Red analysis and for blood vessel quantification. Results No significant difference was observed among the groups regarding collagen realignment (types I or III collagen or quantity of blood vessels. Conclusion High voltage pulsed current for six consecutive days was not effective in collagen realignment, synthesis, or angiogenesis after the partial rupturing of the Achilles tendon in rats.

  16. Silicone Substrate with Collagen and Carbon Nanotubes Exposed to Pulsed Current for MSC Osteodifferentiation

    Directory of Open Access Journals (Sweden)

    Daniyal Jamal

    2017-01-01

    Full Text Available Autologous human adipose tissue-derived mesenchymal stem cells (MSCs have the potential for clinical translation through their induction into osteoblasts for regeneration. Bone healing can be driven by biophysical stimulation using electricity for activating quiescent adult stem cells. It is hypothesized that application of electric current will enhance their osteogenic differentiation, and addition of conductive carbon nanotubes (CNTs to the cell substrate will provide increased efficiency in current transmission. Cultured MSCs were seeded and grown onto fabricated silicone-based composites containing collagen and CNT fibers. Chemical inducers, namely, glycerol phosphate, dexamethasone, and vitamin C, were then added to the medium, and pulsatile submilliampere electrical currents (about half mA for 5 cycles at 4 mHz, twice a week were applied for two weeks. Calcium deposition indicative of MSC differentiation and osteoblastic activity was quantified through Alizarin Red S and spectroscopy. It was found that pulsed current significantly increased osteodifferentiation on silicone-collagen films without CNTs. Under no external current, the presence of 10% (m/m CNTs led to a significant and almost triple upregulation of calcium deposition. Both CNTs and current parameters did not appear to be synergistic. These conditions of enhanced osteoblastic activities may further be explored ultimately towards future therapeutic use of MSCs.

  17. Dynamic response of thermal neutron measurements in electrochemically produced cold fusion subject to pulsed current

    International Nuclear Information System (INIS)

    Granada, Jose; Converti, Jose; Mayer, Roberto; Guido, German; Florido, Pablo; Patino, Nestor; Sobehart, Leonardo; Gomez, Silvia; Larreteguy, Axel

    1988-01-01

    The present work shows the results of measurements performed on electrolytic cells using a high efficiency (22%) neutron detection system in combination with a procedure involving a non-stationary current through the cell's circuit. Cold fusion was produced in electrolytic cells containing LiH dissolved in heavy water with a palladium cathode. The dynamic response to low frequency current pulses was measured. Characteristic patterns showing one or two bumps were obtained in a repeatable fashion. These patterns are strongly dependent on the previous charging history of the cathode. The technique employed seems to be very convenient as a research tool for a systematic study of the different variables governing the phenomenon. (Author)

  18. Eddy Current Pulsed Thermography with Different Excitation Configurations for Metallic Material and Defect Characterization

    Directory of Open Access Journals (Sweden)

    Gui Yun Tian

    2016-06-01

    Full Text Available This paper reviews recent developments of eddy current pulsed thermography (ECPT for material characterization and nondestructive evaluation (NDE. Due to the fact that line-coil-based ECPT, with the limitation of non-uniform heating and a restricted view, is not suitable for complex geometry structures evaluation, Helmholtz coils and ferrite-yoke-based excitation configurations of ECPT are proposed and compared. Simulations and experiments of new ECPT configurations considering the multi-physical-phenomenon of hysteresis losses, stray losses, and eddy current heating in conjunction with uniform induction magnetic field have been conducted and implemented for ferromagnetic and non-ferromagnetic materials. These configurations of ECPT for metallic material and defect characterization are discussed and compared with conventional line-coil configuration. The results indicate that the proposed ECPT excitation configurations can be applied for different shapes of samples such as turbine blade edges and rail tracks.

  19. Analytical description of generation of the residual current density in the plasma produced by a few-cycle laser pulse

    Energy Technology Data Exchange (ETDEWEB)

    Silaev, A. A., E-mail: silaev@appl.sci-nnov.ru; Vvedenskii, N. V., E-mail: vved@appl.sci-nnov.ru [Institute of Applied Physics, Russian Academy of Sciences, Nizhny Novgorod 603950 (Russian Federation); University of Nizhny Novgorod, Nizhny Novgorod 603950 (Russian Federation)

    2015-05-15

    When a gas is ionized by a few-cycle laser pulse, some residual current density (RCD) of free electrons remains in the produced plasma after the passage of the laser pulse. This quasi-dc RCD is an initial impetus to plasma polarization and excitation of the plasma oscillations which can radiate terahertz (THz) waves. In this work, the analytical model for calculation of RCD excited by a few-cycle laser pulse is developed for the first time. The dependences of the RCD on the carrier-envelope phase (CEP), wavelength, duration, and intensity of the laser pulse are derived. It is shown that maximum RCD corresponding to optimal CEP increases with the laser pulse wavelength, which indicates the prospects of using mid-infrared few-cycle laser pulses in the schemes of generation of high-power THz pulses. Analytical formulas for optimal pulse intensity and maximum efficiency of excitation of the RCD are obtained. Basing on numerical solution of the 3D time-dependent Schrödinger equation for hydrogen atoms, RCD dependence on CEP is calculated in a wide range of wavelengths. High accuracy of analytical formulas is demonstrated at the laser pulse parameters which correspond to the tunneling regime of ionization.

  20. Low-noise pulse-mode current power supply for magnetic field measurements of magnets for accelerators

    International Nuclear Information System (INIS)

    Omel'yanenko, M.M.; Borisov, V.V.; Donyagin, A.M.; Kostromin, S.A.; Makarov, A.A.; Khodzhibagiyan, G.G.; Shemchuk, A.V.

    2017-01-01

    The described pulse-mode current power supply has been designed and fabricated for the magnetic field measurement system of superconducting magnets for accelerators. The power supply is based on a current regulator with pass transistor bank in linear mode. The output current pulses (0-100 A) are produced by using the energy of preliminary charged capacitor bank (5-40 V), which is charged additionally after each pulse. There is no AC-line frequency and harmonics ripple in the output current, the relative noise level is less than -100 dB (or 10 -5 ) of RMS value (it is defined as the ratio of output RMS noise current to the maximal output current 100 A within the operating bandwidth, expressed in dB).

  1. Structural and phase transformations in zinc and brass wires under heating with high-density current pulse

    Energy Technology Data Exchange (ETDEWEB)

    Pervikov, A. V. [Laboratory of Physical Chemistry of Ultrafine Materials, Institute of Strength Physics and Materials Science, 2/4, pr. Akademicheskii, 634021 Tomsk, Russia and Department of High Voltage Electrophysics and High Current Electronics, Tomsk Polytechnic University, 30 Lenin Avenue, 634050 Tomsk (Russian Federation)

    2016-06-15

    The work is focused on revealing the mechanism of structure and phase transformations in the metal wires under heating with a high-density current pulse (the electric explosion of wires, EEWs). It has been demonstrated on the example of brass and zinc wires that the transition of a current pulse with the density of j ≈ 3.3 × 10{sup 7} A/cm{sup 2} results in homogeneous heating of the crystalline structure of the metal/alloy. It has been determined that under heating with a pulse of high-density current pulse, the electric resistance of the liquid phases of zinc and brass decreases as the temperature increases. The results obtained allow for a conclusion that the presence of the particles of the condensed phase in the expanding products of EEW is the result of overheating instabilities in the liquid metal.

  2. Exponential current pulse generation for efficient very high-impedance multisite stimulation.

    Science.gov (United States)

    Ethier, S; Sawan, M

    2011-02-01

    We describe in this paper an intracortical current-pulse generator for high-impedance microstimulation. This dual-chip system features a stimuli generator and a high-voltage electrode driver. The stimuli generator produces flexible rising exponential pulses in addition to standard rectangular stimuli. This novel stimulation waveform is expected to provide superior energy efficiency for action potential triggering while releasing less toxic reduced ions in the cortical tissues. The proposed fully integrated electrode driver is used as the output stage where high-voltage supplies are generated on-chip to significantly increase the voltage compliance for stimulation through high-impedance electrode-tissue interfaces. The stimuli generator has been implemented in 0.18-μm CMOS technology while a 0.8-μm CMOS/DMOS process has been used to integrate the high-voltage output stage. Experimental results show that the rectangular pulses cover a range of 1.6 to 167.2 μA with a DNL and an INL of 0.098 and 0.163 least-significant bit, respectively. The maximal dynamic range of the generated exponential reaches 34.36 dB at full scale within an error of ± 0.5 dB while all of its parameters (amplitude, duration, and time constant) are independently programmable over wide ranges. This chip consumes a maximum of 88.3 μ W in the exponential mode. High-voltage supplies of 8.95 and -8.46 V are generated by the output stage, boosting the voltage swing up to 13.6 V for a load as high as 100 kΩ.

  3. Study on Nanostructures Induced by High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    Bo Gao

    2012-01-01

    Full Text Available Four techniques using high-current pulsed electron beam (HCPEB were proposed to obtain surface nanostructure of metal and alloys. The first method involves the distribution of several fine Mg nanoparticles on the top surface of treated samples by evaporation of pure Mg with low boiling point. The second technique uses superfast heating, melting, and cooling induced by HCPEB irradiation to refine the primary phase or the second phase in alloys to nanosized uniform distributed phases in the matrix, such as the quasicrystal phase Mg30Zn60Y10 in the quasicrystal alloy Mg67Zn30Y3. The third technique involves the refinement of eutectic silicon phase in hypereutectic Al-15Si alloys to fine particles with the size of several nanometers through solid solution and precipitation refinement. Finally, in the deformation zone induced by HCPEB irradiation, the grain size can be refined to several hundred nanometers, such as the grain size of the hypereutectic Al-15Si alloys in the deformation zone, which can reach ~400 nm after HCPEB treatment for 25 pulses. Therefore, HCPEB technology is an efficient way to obtain surface nanostructure.

  4. Guiding out-migrating juvenile sea lamprey (Petromyzon marinus) with pulsed direct current

    Science.gov (United States)

    Johnson, Nicholas S.; Miehls, Scott M.

    2014-01-01

    Non-physical stimuli can deter or guide fish without affecting water flow or navigation and therefore have been investigated to improve fish passage at anthropogenic barriers and to control movement of invasive fish. Upstream fish migration can be blocked or guided without physical structure by electrifying the water, but directional downstream fish guidance with electricity has received little attention. We tested two non-uniform pulsed direct current electric systems, each having different electrode orientations (vertical versus horizontal), to determine their ability to guide out-migrating juvenile sea lamprey (Petromyzon marinus) and rainbow trout (Oncorhynchus mykiss). Both systems guided significantly more juvenile sea lamprey to a specific location in our experimental raceway when activated than when deactivated, but guidance efficiency decreased at the highest water velocities tested. At the electric field setting that effectively guided sea lamprey, rainbow trout were guided by the vertical electrode system, but most were blocked by the horizontal electrode system. Additional research should characterize the response of other species to non-uniform fields of pulsed DC and develop electrode configurations that guide fish over a range of water velocity.

  5. Efficient Charging of Li-Ion Batteries with Pulsed Output Current of Triboelectric Nanogenerators.

    Science.gov (United States)

    Pu, Xiong; Liu, Mengmeng; Li, Linxuan; Zhang, Chi; Pang, Yaokun; Jiang, Chunyan; Shao, Lihua; Hu, Weiguo; Wang, Zhong Lin

    2016-01-01

    The triboelectric nanogenerator (TENG) is a promising mechanical energy harvesting technology, but its pulsed output and the instability of input energy sources make associated energy-storage devices necessary for real applications. In this work, feasible and efficient charging of Li-ion batteries by a rotating TENG with pulsed output current is demonstrated. In-depth discussions are made on how to maximize the power-storage efficiency by achieving an impedance match between the TENG and a battery with appropriate design of transformers. With a transformer coil ratio of 36.7, ≈72.4% of the power generated by the TENG at 250 rpm can be stored in an LiFePO 4 -Li 4 Ti 5 O 12 battery. Moreover, a 1 h charging of an LiCoO 2 -C battery by the TENG at 600 rpm delivers a discharge capacity of 130 mAh, capable of powering many smart electronics. Considering the readily scale-up capability of the TENG, promising applications in personal electronics can be anticipated in the near future.

  6. Efficient Charging of Li‐Ion Batteries with Pulsed Output Current of Triboelectric Nanogenerators

    Science.gov (United States)

    Pu, Xiong; Liu, Mengmeng; Li, Linxuan; Zhang, Chi; Pang, Yaokun; Jiang, Chunyan; Shao, Lihua

    2016-01-01

    The triboelectric nanogenerator (TENG) is a promising mechanical energy harvesting technology, but its pulsed output and the instability of input energy sources make associated energy‐storage devices necessary for real applications. In this work, feasible and efficient charging of Li‐ion batteries by a rotating TENG with pulsed output current is demonstrated. In‐depth discussions are made on how to maximize the power‐storage efficiency by achieving an impedance match between the TENG and a battery with appropriate design of transformers. With a transformer coil ratio of 36.7, ≈72.4% of the power generated by the TENG at 250 rpm can be stored in an LiFePO4–Li4Ti5O12 battery. Moreover, a 1 h charging of an LiCoO2–C battery by the TENG at 600 rpm delivers a discharge capacity of 130 mAh, capable of powering many smart electronics. Considering the readily scale‐up capability of the TENG, promising applications in personal electronics can be anticipated in the near future. PMID:27774382

  7. Magnetically driven isentropic compression to multimegabar pressures using shaped current pulses on the Z accelerator

    International Nuclear Information System (INIS)

    Davis, Jean-Paul; Deeney, Christopher; Knudson, Marcus D.; Lemke, Raymond W.; Pointon, Timothy D.; Bliss, David E.

    2005-01-01

    A technique has previously been developed on the Z accelerator [R. B. Spielman et al., Phys. Plasmas 5, 2105 (1998)] to generate ramped compression waves in condensed matter for equation-of-state studies [C. A. Hall, J. R. Asay, M. D. Knudson, W. A. Stygar, R. B. Spielman, T. D. Pointon, D. B. Reisman, A. Toor, and R. C. Cauble, Rev. Sci. Instrum. 72, 3587 (2001)] by using the Lorentz force to push on solid electrodes rather than to drive a Z pinch. This technique has now been extended to multimegabar pressures by shaping the current pulse on Z to significantly increase the sample thickness through which the compression wave can propagate without forming a shock. Shockless, free-surface velocity measurements from multiple sample thicknesses on a single experiment can be analyzed using a backward integration technique [D. B. Hayes, C. A. Hall, J. R. Asay, and M. D. Knudson, J. Appl. Phys. 94, 2331 (2003)] to extract an isentropic loading curve. At very high pressures, the accuracy of this method is dominated by relative uncertainty in the transit time between two thicknesses. This paper discusses in some detail the issues involved with accurate measurement of a multimegabar isentrope, including experiment design trade-offs and mechanics of pulse shaping on Z

  8. High rate deposition of thin film cadmium sulphide by pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lisco, F., E-mail: F.Lisco@lboro.ac.uk [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Kaminski, P.M.; Abbas, A.; Bowers, J.W.; Claudio, G. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom); Losurdo, M. [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR, via Orabona 4, 70126 Bari (Italy); Walls, J.M. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom)

    2015-01-01

    Cadmium Sulphide (CdS) is an important n-type semiconductor widely used as a window layer in thin film photovoltaics Copper Indium Selenide, Copper Indium Gallium (di)Selenide, Copper Zinc Tin Sulphide and Cadmium Telluride (CdTe). Cadmium Sulphide has been deposited using a number of techniques but these techniques can be slow (chemical bath deposition and Radio Frequency sputtering) or the uniformity and the control of thickness can be relatively difficult (close space sublimation). In this paper we report on the development of a process using pulsed Direct Current magnetron sputtering which allows nanometre control of thin film thickness using time only. The CdS thin films deposited in this process are highly uniform and smooth. They exhibit the preferred hexagonal structure at room temperature deposition and they have excellent optical properties. Importantly, the process is highly stable despite the use of a semi-insulating magnetron target. Moreover, the process is very fast. The deposition rate using 1.5 kW of power to a 6-inch circular magnetron was measured to be greater than 8 nm/s. This makes the process suitable for industrial deployment. - Highlights: • Pulsed DC magnetron sputtering of CdS • High deposition rate deposition • Uniform, pinhole free films.

  9. Stability of high current diode under 100-nanosecond-pulse voltage

    International Nuclear Information System (INIS)

    Lai Dingguo; Qiu Aici; Zhang Yongmin; Huang Jianjun; Ren Shuqing; Yang Li

    2012-01-01

    Stability of high current diode under pulse voltage with 80 ns and 34 ns rise time was studied on the flash Ⅱ accelerator. Influence of rise time of diode voltage on startup time and cathode emission uniformity and repeatability of diode impedance was analyzed by comparing the experimental results with numerically simulated results, and the influence mechanism was discussed. The startup time of diode increases with the increasing of rise time of voltage, and the repeatability of diode impedance decreases. Discal plane cathode is prone to emit rays intensely in the center area, the time that plasma covers the surface of the cathode increases and the shielding effect has more impact on cathode emission according to the increase of rise time. Local intense emission on the cathode increases expansion speed of plasma and reduces the effective emission area. The stability of characteristic impedance of diode under a pulse voltage with slow rise time is decreased by the combined action of expansion speed of plasma and the effective emission area. (authors)

  10. High rate deposition of thin film cadmium sulphide by pulsed direct current magnetron sputtering

    International Nuclear Information System (INIS)

    Lisco, F.; Kaminski, P.M.; Abbas, A.; Bowers, J.W.; Claudio, G.; Losurdo, M.; Walls, J.M.

    2015-01-01

    Cadmium Sulphide (CdS) is an important n-type semiconductor widely used as a window layer in thin film photovoltaics Copper Indium Selenide, Copper Indium Gallium (di)Selenide, Copper Zinc Tin Sulphide and Cadmium Telluride (CdTe). Cadmium Sulphide has been deposited using a number of techniques but these techniques can be slow (chemical bath deposition and Radio Frequency sputtering) or the uniformity and the control of thickness can be relatively difficult (close space sublimation). In this paper we report on the development of a process using pulsed Direct Current magnetron sputtering which allows nanometre control of thin film thickness using time only. The CdS thin films deposited in this process are highly uniform and smooth. They exhibit the preferred hexagonal structure at room temperature deposition and they have excellent optical properties. Importantly, the process is highly stable despite the use of a semi-insulating magnetron target. Moreover, the process is very fast. The deposition rate using 1.5 kW of power to a 6-inch circular magnetron was measured to be greater than 8 nm/s. This makes the process suitable for industrial deployment. - Highlights: • Pulsed DC magnetron sputtering of CdS • High deposition rate deposition • Uniform, pinhole free films

  11. Two-dimensional analysis of beat wave current drive with intense microwave pulses

    International Nuclear Information System (INIS)

    Amin, M.R.; Cairns, R.A.

    1990-01-01

    Current drive in tokamak plasmas by a beat wave is considered in two-dimensional (2-D) geometry. The beat wave is excited by the non-linear interaction of two intense microwave pulses (free electron lasers) in the plasma. The three-wave non-linear interaction equations in steady state are solved numerically. The 2-D toroidal effect and the effect of finite spatial width of the pump microwave pulses are taken into account for the excitation of the beat mode. To illustrate the principle, two types of tokamak are considered: one is small, such as, typically, the Microwave Tokamak Experiment (MTX). and the other one is larger, such as the Joint European Torus (JET). In both cases, it is found that good beat wave coupling exists for a Langmuir beat wave with a phase velocity of around 2.0 to 4.0 times the thermal velocity of the electrons. The fraction of total input power of the right circularly polarized pump waves deposited in the beat mode can be as high as 29% in JET and 32% in MTX. In these cases, there is almost complete pump depletion of the higher frequency pump microwave. It is also found that, for the same input parameters, left circularly polarized pump waves are less efficient than right circularly polarized pump waves for depositing power in the beat mode. (author). 12 refs, 15 figs, 5 tabs

  12. Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry

    Energy Technology Data Exchange (ETDEWEB)

    Guerreiro, Gabriela V.; Zaitouna, Anita J.; Lai, Rebecca Y., E-mail: rlai2@unl.edu

    2014-01-31

    Graphical abstract: -- Highlights: •An electrochemical Hg(II) sensor based on T–Hg(II)–T sensing motif was fabricated. •A methylene blue-modified DNA probe was used to fabricate the sensor. •Sensor performance was evaluated using ACV, CV, SWV, and DPV. •The sensor behaves as a “signal-off” sensor in ACV and CV. •The sensor behaves as either a “signal-on” or “signal-off” sensor in SWV and DPV. -- Abstract: Here we report the characterization of an electrochemical mercury (Hg{sup 2+}) sensor constructed with a methylene blue (MB)-modified and thymine-containing linear DNA probe. Similar to the linear probe electrochemical DNA sensor, the resultant sensor behaved as a “signal-off” sensor in alternating current voltammetry and cyclic voltammetry. However, depending on the applied frequency or pulse width, the sensor can behave as either a “signal-off” or “signal-on” sensor in square wave voltammetry (SWV) and differential pulse voltammetry (DPV). In SWV, the sensor showed “signal-on” behavior at low frequencies and “signal-off” behavior at high frequencies. In DPV, the sensor showed “signal-off” behavior at short pulse widths and “signal-on” behavior at long pulse widths. Independent of the sensor interrogation technique, the limit of detection was found to be 10 nM, with a linear dynamic range between 10 nM and 500 nM. In addition, the sensor responded to Hg{sup 2+} rather rapidly; majority of the signal change occurred in <20 min. Overall, the sensor retains all the characteristics of this class of sensors; it is reagentless, reusable, sensitive, specific and selective. This study also highlights the feasibility of using a MB-modified probe for real-time sensing of Hg{sup 2+}, which has not been previously reported. More importantly, the observed “switching” behavior in SWV and DPV is potentially generalizable and should be applicable to most sensors in this class of dynamics-based electrochemical biosensors.

  13. Increase in operation safety of high-current pulsed accelerators by means of nonlinear resistances

    International Nuclear Information System (INIS)

    Demidov, B.A.; Ivkin, M.V.; Petrov, V.A.; Fanchenko, S.D.

    1975-01-01

    A circuit for connecting a shaping line through a nonlinear resistor in a high-current pulsed accelerator is proposed and investigated experimentally. For experimental purposes standard resistors are used as nonlinear resistors, they are made in the form of cylinders 100 mm in dia and 60 mm long. The results obtained show that if two resistors are connected in series, the reduction in an initial potential is less than 5% at the logarithmic damping coefficient equal to 1.3. It is also shown that such a method allows elimination of the reverse pumpover of energy to the storage device for untimely actuation of a spark gap that results in the prolongation of the time of potential applying thereby it permits a substantial increase in the reliability of a high-voltage insulation [ru

  14. A Study of Applying Pulsed Remote Field Eddy Current in Ferromagnetic Pipes Testing.

    Science.gov (United States)

    Luo, Qingwang; Shi, Yibing; Wang, Zhigang; Zhang, Wei; Li, Yanjun

    2017-05-05

    Pulsed Remote Field Eddy Current Testing (PRFECT) attracts the attention in the testing of ferromagnetic pipes because of its continuous spectrum. This paper simulated the practical PRFECT of pipes by using ANSYS software and employed Least Squares Support Vector Regression (LSSVR) to extract the zero-crossing time to analyze the pipe thickness. As a result, a secondary peak is found in zero-crossing time when transmitter passed by a defect. The secondary peak will lead to wrong quantification and the localization of defects, especially when defects are found only at the transmitter location. Aiming to eliminate the secondary peaks, double sensing coils are set in the transition zone and Wiener deconvolution filter is applied. In the proposed method, position dependent response of the differential signals from the double sensing coils is calibrated by employing zero-mean normalization. The methods proposed in this paper are validated by analyzing the simulation signals and can improve the practicality of PRFECT of ferromagnetic pipes.

  15. Effect of pulse current on energy consumption and removal of heavy metals during electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian Ran

    : transport of water (electroosmosis) and ions (electromigration), with electromigration being the most important transport process when treating heavy metal contaminated soils. Electrodialytic remediation (EDR), one of the enhanced electrochemical remediation techniques, is developed at the Technical...... University of Denmark in the early 1990s and aims at removal of heavy metals from contaminated soils. The electrodialytic remediation method differs from the electrokinetic remediation methods in the use of ion exchange membranes for separation of the soil and the processing solutions in the electrode...... the applicability for remediation beyond bench and pilot scale. The overall aim of the present PhD study is to clarify and understand the underlying mechanisms of the effect of pulse current on energy consumption and removal of heavy metals during electrodialytic soil remediation. Series of experiments...

  16. X-ray framing camera for pulsed, high current, electron beam x-ray sources

    CERN Document Server

    Failor, B H; Riordan, j c; Lojewski, D Y

    2007-01-01

    High power x-ray sources built for nuclear weapons effects testing are evolving toward larger overall diameters and smaller anode cathode gaps. We describe a framing camera developed to measure the time-evolution of these 20-50 ns pulsed x-ray sources produced by currents in the 1.5-2.5 MA range and endpoint voltages between 0.2 and 1.5 MV. The camera has up to 4 frames with 5 ns gate widths; the frames are separated by 5 ns. The image data are recorded electronically with a gated intensified CCD camera and the data are available immediately following a shot. A fast plastic scintillator (2.1 ns decay time) converts the x-rays to visible light and, for high sensitivity, a fiber optic imaging bundle carries the light to the CCD input. Examples of image data are shown.

  17. Pulsed eddy current and ultrasonic data fusion applied to stress measurement

    International Nuclear Information System (INIS)

    Habibalahi, A; Safizadeh, M S

    2014-01-01

    Stress measurement and its variation are key problems in the operating performance of materials. Stress can affect the material properties and the life of components. There are several destructive and nondestructive techniques that are used to measure stress. However, no single nondestructive testing (NDT) technique or method is satisfactory to fully assess stress. This paper presents an NDT data fusion method to improve stress measurement. An aluminum alloy 2024 specimen subjected to stress simulation is nondestructively inspected using pulsed eddy current and ultrasonic techniques. Following these nondestructive examinations, the information gathered from these two NDT methods has been fused using a suitable fuzzy combination operator. The results obtained with these processes are presented in this paper and their efficiency is discussed. It is shown that the fusion of NDT data with a suitable fuzzy operator can be adequate to improve the reliability of stress measurements. (paper)

  18. Effects of direct current and pulse-reverse copper plating waveforms on the incubation behavior of self-annealing

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Min-Yuan [Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, 300 Taiwan (China); Chen, Kei-Wei, E-mail: kwchena@aa.nctu.edu.t [Department of Materials Science, National University of Tainan, Tainan, 700 Taiwan (China); Liu, Tzeng-Feng [Department of Materials Science and Engineering, National Chiao Tung University, Hsinchu, 300 Taiwan (China); Wang, Ying-Lang [Department of Materials Science, National University of Tainan, Tainan, 700 Taiwan (China); Feng, Hsien-Ping [Department of Chemical Engineering, National Tsing Hua University, Hsinchu, 300 Taiwan (China)

    2010-10-01

    This study investigates spontaneous microstructural evolution in electroplated Cu films with various plating current densities involving direct current and pulse-reverse waveforms and various possible driving forces. Studies have explained the grain growth and resistivity decrease during the self-annealing of as-deposited Cu film, but the incubation behavior of self-annealing under various direct current and pulse-reverse current waveforms at a certain film thickness is unknown. In this study, it was found that pulse-reverse current retards the incubation behavior more significantly than does direct current. According to the measurements of resistivity, stress, and secondary ion mass spectrometer, the large stress difference between the initial and critical values and the low impurity content of pulse-reverse current postponed the incubation, and led to a slow self-annealing rate. The combination of the stress difference and the impurity effect explains the incubation behavior of self-annealing under various plating current densities. The resistivity and X-ray diffraction results suggest that stress is the primary driving force that dramatically speeds up grain growth above the critical stress, and that high current density with a rapid grain growth rate enhances the (200) texture for strain energy minimization in electroplated Cu film.

  19. Cranial electrotherapy stimulation and transcranial pulsed current stimulation: a computer based high-resolution modeling study.

    Science.gov (United States)

    Datta, Abhishek; Dmochowski, Jacek P; Guleyupoglu, Berkan; Bikson, Marom; Fregni, Felipe

    2013-01-15

    The field of non-invasive brain stimulation has developed significantly over the last two decades. Though two techniques of noninvasive brain stimulation--transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS)--are becoming established tools for research in neuroscience and for some clinical applications, related techniques that also show some promising clinical results have not been developed at the same pace. One of these related techniques is cranial electrotherapy stimulation (CES), a class of transcranial pulsed current stimulation (tPCS). In order to understand further the mechanisms of CES, we aimed to model CES using a magnetic resonance imaging (MRI)-derived finite element head model including cortical and also subcortical structures. Cortical electric field (current density) peak intensities and distributions were analyzed. We evaluated different electrode configurations of CES including in-ear and over-ear montages. Our results confirm that significant amounts of current pass the skull and reach cortical and subcortical structures. In addition, depending on the montage, induced currents at subcortical areas, such as midbrain, pons, thalamus and hypothalamus are of similar magnitude than that of cortical areas. Incremental variations of electrode position on the head surface also influence which cortical regions are modulated. The high-resolution modeling predictions suggest that details of electrode montage influence current flow through superficial and deep structures. Finally we present laptop based methods for tPCS dose design using dominant frequency and spherical models. These modeling predictions and tools are the first step to advance rational and optimized use of tPCS and CES. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. Effect of pulse current on acidification and removal of Cu, Cd, and As during suspended electrodialytic soil remediation

    DEFF Research Database (Denmark)

    Sun, Tian Ran; Ottosen, Lisbeth M.; Jensen, Pernille Erland

    2013-01-01

    The effect of pulse current on the acidification process and the removal of heavy metals during suspended electrodialytic soil remediation were investigated in this work. Eight experiments with constant and pulse current in two polluted soils were conducted using a 3-compartment membrane cell...... the acidification by supplying more reactive H+ ions (defined as the H+ ions causing release of heavy metals from soil particles). The molar ratio of reactive H+ ions to total produced H+ ions (RH+/PH+) was higher in every pulse current experiment than in the corresponding constant current experiment. In addition...... the removal efficiencies of heavy metals were also improved. The carbonate buffering system in a soil is the first mechanism reacting with the produced H+ ions and impeding the heavy metal mobilization. It was found that the effect of improvement on both the acidification process and the removal of heavy...

  1. Mechanism of formation of subnanosecond current front in high-voltage pulse open discharge

    Science.gov (United States)

    Schweigert, I. V.; Alexandrov, A. L.; Zakrevsky, Dm. E.; Bokhan, P. A.

    2014-11-01

    The mechanism of subnanosecond current front rise observed previously in the experiment in high-voltage pulse open discharge in helium is studied in kinetic particle-in-cell simulations. The Boltzmann equations for electrons, ions, and fast atoms are solved self-consistently with the Poisson equations for the electrical potential. The partial contributions to the secondary electron emission from the ions, fast atoms, photons, and electrons, bombarding the electrode, are calculated. In simulations, as in the experiment, the discharge glows between two symmetrical cathodes and the anode grid in the midplane at P =6 Torr and the applied voltage of 20 kV. The electron avalanche development is considered for two experimental situations during the last stage of breakdown: (i) with constant voltage and (ii) with decreasing voltage. For case (i), the subnanosecond current front rise is set by photons from the collisional excitation transfer reactions. For the case (ii), the energetic electrons swamp the cathode during voltage drop and provide the secondary electron emission for the subnanosecond current rise, observed in the experiment.

  2. Nonlinear Charge and Current Neutralization of an Ion Beam Pulse in a Pre-formed Plasma

    International Nuclear Information System (INIS)

    Kaganovich, Igor D.; Shvets, Gennady; Startsev, Edward; Davidson, Ronald C.

    2001-01-01

    The propagation of a high-current finite-length ion beam in a cold pre-formed plasma is investigated. The outcome of the calculation is the quantitative prediction of the degree of charge and current neutralization of the ion beam pulse by the background plasma. The electric magnetic fields generated by the ion beam are studied analytically for the nonlinear case where the plasma density is comparable in size with the beam density. Particle-in-cell simulations and fluid calculations of current and charge neutralization have been performed for parameters relevant to heavy ion fusion assuming long, dense beams with el >> V(subscript b)/omega(subscript b), where V(subscript b) is the beam velocity and omega subscript b is the electron plasma frequency evaluated with the ion beam density. An important conclusion is that for long, nonrelativistic ion beams, charge neutralization is, for all practical purposes, complete even for very tenuous background plasmas. As a result, the self-magnetic force dominates the electric force and the beam ions are always pinched during beam propagation in a background plasma

  3. Measuring Plasma Formation Field Strength and Current Loss in Pulsed Power Diodes

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, Mark D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Patel, Sonal G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Falcon, Ross Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Cartwright, Keith [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Kiefer, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Cuneo, Michael E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Maron, Yitzhak [Weizmann Inst. of Science, Rehovot (Israel)

    2017-11-01

    This LDRD investigated plasma formation, field strength, and current loss in pulsed power diodes. In particular the Self-Magnetic Pinch (SMP) e-beam diode was studied on the RITS-6 accelerator. Magnetic fields of a few Tesla and electric fields of several MV/cm were measured using visible spectroscopy techniques. The magnetic field measurements were then used to determine the current distribution in the diode. This distribution showed that significant beam current extends radially beyond the few millimeter x-ray focal spot diameter. Additionally, shielding of the magnetic field due to dense electrode surface plasmas was observed, quantified, and found to be consistent with the calculated Spitzer resistivity. In addition to the work on RITS, measurements were also made on the Z-machine looking to quantify plasmas within the power flow regions. Measurements were taken in the post-hole convolute and final feed gap regions on Z. Dopants were applied to power flow surfaces and measured spectroscopically. These measurements gave species and density/temperature estimates. Preliminary B-field measurements in the load region were attempted as well. Finally, simulation work using the EMPHASIS, electromagnetic particle in cell code, was conducted using the Z MITL conditions. The purpose of these simulations was to investigate several surface plasma generations models under Z conditions for comparison with experimental data.

  4. Spin-photo-currents generated by femtosecond laser pulses in a ferrimagnetic GdFeCo/Pt bilayer

    Science.gov (United States)

    Huisman, T. J.; Ciccarelli, C.; Tsukamoto, A.; Mikhaylovskiy, R. V.; Rasing, Th.; Kimel, A. V.

    2017-02-01

    Using THz emission spectroscopy, we detect spin-photo-currents from a ferrimagnetic amorphous alloy GdFeCo to an adjacent Pt capping layer. The currents are generated upon excitation of a GdFeCo/Pt heterostructure with femtosecond laser pulses. It is found that the polarization of the spin-polarized current is determined by magnetic sublattice sensitivity rather than the total magnetization, allowing for spin-polarized current generation when the net magnetization is zero.

  5. A model of preliminary breakdown pulse peak currents and their relation to the observed electric-field pulses

    Czech Academy of Sciences Publication Activity Database

    Kašpar, Petr; Santolík, Ondřej; Kolmašová, Ivana; Farges, T.

    2017-01-01

    Roč. 44, č. 1 (2017), s. 596-603 ISSN 0094-8276 R&D Projects: GA ČR(CZ) GA14-31899S Grant - others:AV ČR(CZ) AP1401 Program:Akademická prémie - Praemium Academiae Institutional support: RVO:68378289 Keywords : lightning initiation * electromagnetic radiation * preliminary breakdown pulses Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 4.253, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/2016GL071483/pdf

  6. Electron beam dynamics in the long-pulse, high-current DARHT-II linear induction accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ekdahl, Carl A [Los Alamos National Laboratory; Abeyta, Epifanio O [Los Alamos National Laboratory; Aragon, Paul [Los Alamos National Laboratory; Archuleta, Rita [Los Alamos National Laboratory; Cook, Gerald [Los Alamos National Laboratory; Dalmas, Dale [Los Alamos National Laboratory; Esquibel, Kevin [Los Alamos National Laboratory; Gallegos, Robert A [Los Alamos National Laboratory; Garnett, Robert [Los Alamos National Laboratory; Harrison, James F [Los Alamos National Laboratory; Johnson, Jeffrey B [Los Alamos National Laboratory; Jacquez, Edward B [Los Alamos National Laboratory; Mccuistian, Brian T [Los Alamos National Laboratory; Montoya, Nicholas A [Los Alamos National Laboratory; Nath, Subrato [Los Alamos National Laboratory; Nielsen, Kurt [Los Alamos National Laboratory; Oro, David [Los Alamos National Laboratory; Prichard, Benjamin [Los Alamos National Laboratory; Rowton, Lawrence [Los Alamos National Laboratory; Sanchez, Manolito [Los Alamos National Laboratory; Scarpetti, Raymond [Los Alamos National Laboratory; Schauer, Martin M [Los Alamos National Laboratory; Seitz, Gerald [Los Alamos National Laboratory; Schulze, Martin [Los Alamos National Laboratory; Bender, Howard A [Los Alamos National Laboratory; Broste, William B [Los Alamos National Laboratory; Carlson, Carl A [Los Alamos National Laboratory; Frayer, Daniel K [Los Alamos National Laboratory; Johnson, Douglas E [Los Alamos National Laboratory; Tom, C Y [Los Alamos National Laboratory; Williams, John [Los Alamos National Laboratory; Hughes, Thomas [Los Alamos National Laboratory; Anaya, Richard [LLNL; Caporaso, George [LLNL; Chambers, Frank [LLNL; Chen, Yu - Jiuan [LLNL; Falabella, Steve [LLNL; Guethlein, Gary [LLNL; Raymond, Brett [LLNL; Richardson, Roger [LLNL; Trainham, C [NSTEC/STL; Watson, Jim [LLNL; Weir, John [LLNL; Genoni, Thomas [VOSS; Toma, Carsten [VOSS

    2009-01-01

    The DARHT-II linear induction accelerator (LIA) now accelerates 2-kA electron beams to more than 17 MeV. This LIA is unique in that the accelerated current pulse width is greater than 2 microseconds. This pulse has a flat-top region where the final electron kinetic energy varies by less than 1% for more than 1.5 microseconds. The long risetime of the 6-cell injector current pulse is 0.5 {micro}s, which can be scraped off in a beam-head cleanup zone before entering the 68-cell main accelerator. We discuss our experience with tuning this novel accelerator; and present data for the resulting beam transport and dynamics. We also present beam stability data, and relate these to previous stability experiments at lower current and energy.

  7. Electron beam dynamics in the long-pulse, high-current DARHT-II linear induction accelerator

    International Nuclear Information System (INIS)

    Ekdahl, Carl A.; Abeyta, Epifanio O.; Aragon, Paul; Archuleta, Rita; Cook, Gerald; Dalmas, Dale; Esquibel, Kevin; Gallegos, Robert A.; Garnett, Robert; Harrison, James F.; Johnson, Jeffrey B.; Jacquez, Edward B.; Mccuistian, Brian T.; Montoya, Nicholas A.; Nath, Subrato; Nielsen, Kurt; Oro, David; Prichard, Benjamin; Rowton, Lawrence; Sanchez, Manolito; Scarpetti, Raymond; Schauer, Martin M.; Seitz, Gerald; Schulze, Martin; Bender, Howard A.; Broste, William B.; Carlson, Carl A.; Frayer, Daniel K.; Johnson, Douglas E.; Tom, C.Y.; Williams, John; Hughes, Thomas; Anaya, Richard; Caporaso, George; Chambers, Frank; Chen, Yu-Jiuan; Falabella, Steve; Guethlein, Gary; Raymond, Brett; Richardson, Roger; Trainham, C.; Watson, Jim; Weir, John; Genoni, Thomas; Toma, Carsten

    2009-01-01

    The DARHT-II linear induction accelerator (LIA) now accelerates 2-kA electron beams to more than 17 MeV. This LIA is unique in that the accelerated current pulse width is greater than 2 microseconds. This pulse has a flat-top region where the final electron kinetic energy varies by less than 1% for more than 1.5 microseconds. The long risetime of the 6-cell injector current pulse is 0.5 (micro)s, which can be scraped off in a beam-head cleanup zone before entering the 68-cell main accelerator. We discuss our experience with tuning this novel accelerator; and present data for the resulting beam transport and dynamics. We also present beam stability data, and relate these to previous stability experiments at lower current and energy.

  8. Application of Streaming Effect and Joule Heating Effect of Pulse Current in Crack Healing of Metal Materials

    Directory of Open Access Journals (Sweden)

    Jian Chu

    2017-06-01

    Full Text Available Remanufacture engineering is an emerging industry that saves resources as well as protects the environment. However, cracks on remanufactured components can result in serious trouble. Therefore, in order to avoid unnecessary waste of resources and energy, these cracks should be repaired radically in order to ensure the smooth progressing of the remanufacturing process. Consequently, the crack healing technique of metal materials is very important in the field of remanufacturing. In this study, the U-shape vane stainless steel of a centrifugal compressor which had cracks was processed by pulse current using a high pulse current discharge device, and the influence of the streaming effect and Joule heating effect of pulse current on the crack healing of metal materials was studied, aiming to provide references for the better application of this technology in the remanufacturing field in the future.

  9. Ways for decrease of inductance of bus arrangements of power pulse current generators

    International Nuclear Information System (INIS)

    Monastyrskij, A.E.; Zajents, S.L.; Popova, V.A.; Chubanova, Yu.A.; Churakova, N.A.; Shneerson, G.A.

    1984-01-01

    The prospects to increase the amplitude of current, produced in a low-inductance load in the process of discharge into it of a capacitive storage-pulse current generator (PCG) are determined by the possibility to decrease PCG internal inductance. Ways to decrease PCG inductance, which is a sum of inductances of capacitors, commutators and connecting line, consisting of intermediate line (buses and cables) and assembly busbars (collector), are considered. It is shown, that a decrease in the intermediate line inductance can be achieved, when parallel buses, separated by insulation gap are used instead of cables. A decrease in the cable line inductance can be achieved at the expense of an increase in the electric field operation intensity in insulation. The most perspective way to increase electrical strength of terminal devices consists in the application of polymer coatings and high specific resistance films. A possible arrangement of the capacitive storage, designed for the operation with a long one-turn solenoid, is shown. The capacitor bus arrangement presents a combination of flat and bax buses. The values of the capacitor element inductance in calculation per 1 MJ of stored energy are presented. The capacitor inductance can be less than 1 nH

  10. Quantitative Detection of Cracks in Steel Using Eddy Current Pulsed Thermography

    Directory of Open Access Journals (Sweden)

    Zhanqun Shi

    2018-04-01

    Full Text Available Small cracks are common defects in steel and often lead to catastrophic accidents in industrial applications. Various nondestructive testing methods have been investigated for crack detection; however, most current methods focus on qualitative crack identification and image processing. In this study, eddy current pulsed thermography (ECPT was applied for quantitative crack detection based on derivative analysis of temperature variation. The effects of the incentive parameters on the temperature variation were analyzed in the simulation study. The crack profile and position are identified in the thermal image based on the Canny edge detection algorithm. Then, one or more trajectories are determined through the crack profile in order to determine the crack boundary through its temperature distribution. The slope curve along the trajectory is obtained. Finally, quantitative analysis of the crack sizes was performed by analyzing the features of the slope curves. The experimental verification showed that the crack sizes could be quantitatively detected with errors of less than 1%. Therefore, the proposed ECPT method was demonstrated to be a feasible and effective nondestructive approach for quantitative crack detection.

  11. Quantitative Detection of Cracks in Steel Using Eddy Current Pulsed Thermography.

    Science.gov (United States)

    Shi, Zhanqun; Xu, Xiaoyu; Ma, Jiaojiao; Zhen, Dong; Zhang, Hao

    2018-04-02

    Small cracks are common defects in steel and often lead to catastrophic accidents in industrial applications. Various nondestructive testing methods have been investigated for crack detection; however, most current methods focus on qualitative crack identification and image processing. In this study, eddy current pulsed thermography (ECPT) was applied for quantitative crack detection based on derivative analysis of temperature variation. The effects of the incentive parameters on the temperature variation were analyzed in the simulation study. The crack profile and position are identified in the thermal image based on the Canny edge detection algorithm. Then, one or more trajectories are determined through the crack profile in order to determine the crack boundary through its temperature distribution. The slope curve along the trajectory is obtained. Finally, quantitative analysis of the crack sizes was performed by analyzing the features of the slope curves. The experimental verification showed that the crack sizes could be quantitatively detected with errors of less than 1%. Therefore, the proposed ECPT method was demonstrated to be a feasible and effective nondestructive approach for quantitative crack detection.

  12. Applications of pulsed Eddy Current (PEC) technique on defect and material assessment

    International Nuclear Information System (INIS)

    Nurul A'in Ahmad Latif; Noorhazleena Azaman; Ilham Mukriz Zainal Abidin

    2014-01-01

    The pulsed eddy current (PEC) is an emerging electromagnetic method and widely used in multiple field including aerospace, petrochemical, industry and transportation. PEC mainly depends on the multiple variables such as peak value and rising time to detect and quantify the defects. Apart of its advantage as non contacting technique, it has ability on conducting surface and subsurface detection. Additionally, PEC is high sensitive to variety parameters that are inherent in the flaws. Compare to conventional eddy current, PEC allows deeper penetration as it is a combination from multiple frequencies. This paper demonstrates the abilities of PEC technique performing multiple testing in various fields such as conducting conductivity testing, measuring the material thickness and identifying depth of the defects. The conductivity testing will be performed on multiple materials such as aluminium, stainless steel, copper, austenitic steel and titanium. To measure the material thicknesses, PEC testing will be conducted on the multi layered specimen with the different thickness. Meanwhile to identify depth of defects, the testing will be carried out using a stainless steel calibration block contains multiple length of defect. For the validation purposes, all the results generate through the experiments will be compared with simulation results produced using dedicated software, COMSOL. (author)

  13. Deuteron flux production in a small high-voltage high-current diode with pulsed magnetic insulation

    Science.gov (United States)

    Shikanov, A. E.; Vovchenko, E. D.; Isaev, A. A.; Kozlovskii, K. I.; Shatokhin, V. L.

    2017-06-01

    The results of new studies on the production of accelerated deuteron fluxes in a small ion diode with pulsed magnetic insulation of electrons have been presented. A plasma anode of the diode has been formed under the action of a 1.06 μm laser radiation with a pulse duration of 10 ns, a pulse energy of up to 1 J, and a power density on the target of 5 × 1015 W m-2. An accelerating voltage of up to 300 kV has been created using an Arkad'ev-Marx pulsed voltage generator with a stored energy of 50 J and a repetition rate of 1 Hz. A magnetic field of higher than 0.6 T for insulating electrons has been formed by a current pulse of the first cascade of the generator in a spiral line before a conical cascade. Stable deuteron acceleration to 300 keV with a current of up to 1.5 kA and a pulse duration of 0.3 μs has been achieved.

  14. Evaluation of Motor Neuron Excitability by CMAP Scanning with Electric Modulated Current

    Directory of Open Access Journals (Sweden)

    Tiago Araújo

    2015-01-01

    Full Text Available Introduction. Compound Muscle Action Potential (CMAP scan is a noninvasive promissory technique for neurodegenerative pathologies diagnosis. In this work new CMAP scan protocols were implemented to study the influence of electrical pulse waveform on peripheral nerve excitability. Methods. A total of 13 healthy subjects were tested. Stimulation was performed with an increasing intensities range from 4 to 30 mA. The procedure was repeated 4 times per subject, using a different single pulse stimulation waveform: monophasic square and triangular and quadratic and biphasic square. Results. Different waveforms elicit different intensity-response amplitude curves. The square pulse needs less current to generate the same response amplitude regarding the other waves and this effect is gradually decreasing for the triangular, quadratic, and biphasic pulse, respectively. Conclusion. The stimulation waveform has a direct influence on the stimulus-response slope and consequently on the motoneurons excitability. This can be a new prognostic parameter for neurodegenerative disorders.

  15. Investigation of electrodes under flow of a submicrosecond current pulse with linear density up to 3 MA/cm

    International Nuclear Information System (INIS)

    Branitskii, A. V.; Grabovskii, E. V.; Dzhangobegov, V. V.; Laukhin, Ya. N.; Mitrofanov, K. N.; Oleinik, G. M.; Sasorov, P. V.; Tkachenko, S. I.; Frolov, I. N.

    2016-01-01

    The states of current-carrying elements at the transmission of megaampere current into load are studied. It is determined that the expansion velocity of plasma generated at the outer surface of cylindrical tubes produced of stainless steel, at flowing through them of submicrosecond current pulses with linear density of 3 MA/cm is 5.5 km/s. The evolution of various modes of instability is analyzed.

  16. Electromagnetic Pulse in the Magnetosphere Generated by Impulsive Current near the Lower Boundary of the Ionosphere

    Science.gov (United States)

    Surkov, V. V.; Galperin, Yu. I.

    2000-11-01

    A solution to the problem of current spreading is constructed in the case of relaxation of electric charges, which have arisen in the mesosphere for one reason or other. These currents penetrate into the conductive region with anisotropic conductivity of the D- and E-layers of the ionosphere, being transformed to a MHD-wave that propagates into the magnetosphere. Based on this solution, the form and spectrum of the generated MHD signal are calculated for Alfvenic and magnetosonic modes coming out to the ionosphere and magnetosphere. Electric charges and currents can arise, for example, in the space between a thunderstorm cloud and the ionosphere, or between the shock wave from a ground explosion and the ionosphere. Some signal parameters accepted in the model are close to those expected for high-altitude electric discharges of the Red Sprite type. The conditions are determined under which the Alfven impulse with an amplitude of up to 100 nT propagates in the magnetosphere above high-altitude discharge of this type. Such an impulse was recorded by the AUREOL-3 satellite after the ground explosion MASSA-1. Recently, this impulse was hypothesized to originate as a result of a high-altitude electric discharge. The hypothesis on a similar MHD pulse allows one to explain in a semiquantitative way the short burst of electron field-aligned acceleration observed by the DE-2 satellite over the Debbie hurricane. The high-altitude atmospheric discharge of this type can be a powerful, though short-time and local, source of electrons with kiloelectronvolt energies at low and middle latitudes. One could expect that such an effect causes a modified character of the so-called Trimpi-effect (a short-term disturbance of propagation of VLF waves in the ionosphere), and thus, it can be observable.

  17. Effect of Postweld Aging Treatment on Fatigue Behavior of Pulsed Current Welded AA7075 Aluminum Alloy Joints

    Science.gov (United States)

    Balasubramanian, V.; Ravisankar, V.; Madhusudhan Reddy, G.

    2008-04-01

    This article reports the effect of postweld aging treatment on fatigue behavior of pulsed current welded AA 7075 aluminum alloy joints. AA7075 aluminum alloy (Al-Zn-Mg-Cu alloy) has gathered wide acceptance in the fabrication of light weight structures requiring high strength-to weight ratio, such as transportable bridge girders, military vehicles, road tankers, and railway transport systems. The preferred welding processes of AA7075 aluminum alloy are frequently gas tungsten arc welding (GTAW) process and gas metal arc welding (GMAW) process due to their comparatively easier applicability and better economy. Weld fusion zones typically exhibit coarse columnar grains because of the prevailing thermal conditions during weld metal solidification. This often results inferior weld mechanical properties and poor resistance to hot cracking. In this investigation, an attempt has been made to refine the fusion zone grains by applying pulsed current welding technique. Rolled plates of 10 mm thickness have been used as the base material for preparing multipass welded joints. Single V butt joint configuration has been prepared for joining the plates. The filler metal used for joining the plates is AA 5356 (Al-5Mg (wt.%)) grade aluminum alloy. Four different welding techniques have been used to fabricate the joints and they are: (i) continuous current GTAW (CCGTAW), (ii) pulsed current GTAW (PCGTAW), (iii) continuous current GMAW (CCGMAW), and (iv) pulsed current GMAW (PCGMAW) processes. Argon (99.99% pure) has been used as the shielding gas. Rotary bending fatigue testing machine has been used to evaluate fatigue behavior of the welded joints. Current pulsing leads to relatively finer and more equi-axed grain structure in GTA and GMA welds. Grain refinement is accompanied by an increase in fatigue life and endurance limit. Simple postweld aging treatment applied to the joints is found to be beneficial to enhance the fatigue performance of the welded joints.

  18. Initiation of ignition by the action of a high-current pulsed discharge on a gas

    NARCIS (Netherlands)

    Starikovskii, AY

    2003-01-01

    The possibility of nonthermal initiation of chemical reactions by a uniform pulsed nanosecond discharge is demonstrated. Dependences of variation of the ignition delay on initial conditions are obtained. It is shown that the main role in combustion initiation under conditions of a pulsed gas

  19. Inspection of ferromagnetic support structures from within alloy 800 steam generator tubes using pulsed eddy current

    Science.gov (United States)

    Buck, Jeremy Andrew

    Nondestructive testing is a critical aspect of component lifetime management. Nuclear steam generator (SG) tubes are the thinnest barrier between irradiated primary heat transport system and the secondary heat transport system, whose components are not rated for large radiation fields. Conventional eddy current testing (ECT) and ultrasonic testing are currently employed for inspecting SG tubes, with the former doing most inspections due to speed and reliability based on an understanding of how flaws affect coil impedance parameters when conductors are subjected to harmonically induced currents. However, when multiple degradation modes are present simultaneously near ferromagnetic materials, such as tube fretting, support structure corrosion, and magnetite fouling, ECT reliability decreases. Pulsed eddy current (PEC), which induces transient eddy currents via square wave excitation, has been considered in this thesis to simultaneously examine SG tube and support structure conditions. An array probe consisting of a central driver, coaxial with the tube, and an array of 8 sensing coils, was used in this thesis to perform laboratory measurements. The probe was delivered from the inner diameter (ID) of the SG tube, where support hole diameter, tube frets, and 2D off-centering were varied. When considering two variables simultaneously, scores obtained from a modified principal components analysis (MPCA) were sufficient for parameter extraction. In the case of hole ID variation with two dimensional tube off-centering (three parameters), multiple linear regression (MLR) of the MPCA scores provided good estimates of parameters. However, once a fourth variable, outer diameter tube frets, was introduced, MLR proved insufficient. Artificial neural networks (ANNs) were investigated in order to perform pattern recognition on the MPCA scores to simultaneously extract the four measurement parameters from the data. All models throughout this thesis were created and validated using

  20. Pulsed counter-current ultrasound-assisted extraction and characterization of polysaccharides from Boletus edulis.

    Science.gov (United States)

    You, Qinghong; Yin, Xiulian; Ji, Chaowen

    2014-01-30

    Four methods for extracting polysaccharides from Boletus edulis, namely, hot-water extraction, ultrasonic clearer extraction, static probe ultrasonic extraction, and pulsed counter-current probe ultrasonic extraction (CCPUE), were studied. Results showed that CCPUE has the highest extraction efficiency among the methods studied. Under optimal CCPUE conditions, a B. edulis polysaccharide (BEP) yield of 8.21% was obtained. Three purified fractions, BEP-I, BEP-II, and BEP-III, were obtained through sequential purification by DEAE-52 and Sephadex G-75 chromatography. The average molecular weights of BEP-I, BEP-II, and BEP-III were 10,278, 23,761, and 42,736 Da, respectively. The polysaccharides were mainly composed of xylose, mannose, galactose, and glucose; of these, mannose contents were the highest. The antioxidant activities of the BEPs were further investigated by measurement of their ability to scavenge DPPH and hydroxyl radicals as well as their reducing power. The results indicated that the BEPs have good antioxidant activity. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Surface alloying of aluminum with molybdenum by high-current pulsed electron beam

    Science.gov (United States)

    Xia, Han; Zhang, Conglin; Lv, Peng; Cai, Jie; Jin, Yunxue; Guan, Qingfeng

    2018-02-01

    The surface alloying of pre-coated molybdenum (Mo) film on aluminum (Al) substrate by high-current pulsed electron beam (HCPEB) was investigated. The microstructure and phase analysis were conducted by X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results show that Mo particles were dissolved into Al matrix to form alloying layer, which was composed of Mo, Al and acicular or equiaxed Al5Mo phases after surface alloying. Meanwhile, various structure defects such as dislocation loops, high-density dislocations and dislocation walls were observed in the alloying surface. The corrosion resistance was tested by using potentiodynamic polarization curves and electrochemical impedance spectra (EIS). Electrochemical results indicate that all the alloying samples had better corrosion resistance in 3.5 wt% NaCl solution compared to initial sample. The excellent corrosion resistance is mainly attributed to the combined effect of the structure defects and the addition of Mo element to form a more stable passive film.

  2. Stunning effectiveness of broiler chickens using a two-phase stunner: pulsed direct current followed by sine wave alternating current

    NARCIS (Netherlands)

    Prinz, S.; Coenen, A.M.L.; Ehinger, F.; Oijen, G.B.M. van; Bessei, W.

    2012-01-01

    Stunning efficiency of male and female broiler chickens was analysed in response to the two-phase Simmons step-up stunner. In Phase I, a pulsed DC of 550 Hz is applied in a shallow waterbath. This is immediately followed by Phase II, consisting of a metal plate with sine wave AC of 50 Hz. 120 male

  3. Halo Evolution of Hypereutectic Al-17.5Si Alloy Treated with High-Current Pulsed Electron Beam

    Directory of Open Access Journals (Sweden)

    L. Hu

    2015-01-01

    Full Text Available Halo evolution of an Al-17.5Si alloy surface after treatment with increasing pulse numbers of a high-current pulsed electron beam (HCPEB was investigated. A halo is a ring microstructure resembling a bull’s eye. SEM results indicate that the nanocrystallization of halo induced by HCPEB treatment leads to gradual diffusion of the Si phase. Multiple pulses numbers cause the Si phase to be significantly refined and uniformly distributed. In addition, nanosilicon particles with a grain size of 30~100 nm were formed after HCPEB treatment, as shown by TEM observation. XRD results indicate that Si diffraction peaks broadened after HCPEB treatment. The microhardness tests demonstrate that the microhardness at the midpoint from the halo edge to center decreased sharply from 9770.7 MPa at 5 pulses to 2664.14 MPa at 25 pulses. The relative wear resistance of a 15-pulse sample is effectively improved by a factor of 6.5, exhibiting optimal wear resistance.

  4. Schemes of high-voltage pulse shapers on the basics of stepped transmission lines for high-current accelerators

    International Nuclear Information System (INIS)

    Gordeev, V.S.

    1999-01-01

    In the course of creating high current linear induction accelerators (LIA) there was developed a new type of multi-cascade high-voltage pulse generators designed of homogeneous transmission lines of equal electric length. The examples of different-type schemes of capacitive generator inductive generator and inductive-capacitate type generator are given

  5. An EIS alternative for impedance measurement of a high temperature PEM fuel cell stack based on current pulse injection

    DEFF Research Database (Denmark)

    Jeppesen, Christian; Araya, Samuel Simon; Sahlin, Simon Lennart

    2017-01-01

    In this paper a method for estimating the fuel cell impedance is presented, namely the current pulse injection (CPI) method, which is well suited for online implementation. This method estimates the fuel cell impedance and unlike electrochemical impedance spectroscopy (EIS), it is simple to imple...

  6. Ion energy spectrum just after the application of current pulse for turbulent heating in the TRIAM-1 tokamak

    International Nuclear Information System (INIS)

    Nakamura, Kazuo; Nakamura, Yukio; Hiraki, Naoji; Itoh, Satoshi

    1981-01-01

    Temporal evolution and spatial profile of ion energy spectrum just after the application of current pulse for turbulent heating are investigated experimentally in TRIAM-1 and numerically with a Fokker-Planck equation. Two-component ion energy spectrum formed by turbulent heating relaxes to single one within tau sub(i) (ion collision time). (author)

  7. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  8. Numerically simulated cardiac exposure to electric current densities induced by TASER X-26 pulses in adult men

    Energy Technology Data Exchange (ETDEWEB)

    Leitgeb, N; Niedermayr, F; Neubauer, R; Loos, G, E-mail: norbert.leitgeb@tugraz.a [Institute of Clinical Engineering with European Notified Body of Medical Devices, Graz University of Technology, Inffeldgasse 18, A-8010 Graz (Austria)

    2010-10-21

    There is still an ongoing debate whether or not electronic stun devices (ESDs) induce cardiac fibrillation. To assess the ventricular fibrillation risk of law enforcing electronic control devices, quantitative estimates of cardiac electric current densities induced by delivered electric pulses are essential. Numerical simulations were performed with the finite integration technique and the anatomical model of a standardized European man (NORMAN) segmented into 2 mm voxels and 35 different tissues. The load-dependent delivery of TASER X-26 pulses has been taken into account. Cardiac exposure to electric current densities of vertically and horizontally aligned dart electrodes was quantified and different hit scenarios compared. Since fibrillation thresholds critically depend on exposed volume, the provided quantitative data are essential for risk assessment. The maximum cardiac rms current densities amounted to 7730 A m{sup -2}. Such high current densities and exposed cardiac volumes do not exclude ventricular fibrillation.

  9. Numerically simulated cardiac exposure to electric current densities induced by TASER X-26 pulses in adult men

    Science.gov (United States)

    Leitgeb, N.; Niedermayr, F.; Neubauer, R.; Loos, G.

    2010-10-01

    There is still an ongoing debate whether or not electronic stun devices (ESDs) induce cardiac fibrillation. To assess the ventricular fibrillation risk of law enforcing electronic control devices, quantitative estimates of cardiac electric current densities induced by delivered electric pulses are essential. Numerical simulations were performed with the finite integration technique and the anatomical model of a standardized European man (NORMAN) segmented into 2 mm voxels and 35 different tissues. The load-dependent delivery of TASER X-26 pulses has been taken into account. Cardiac exposure to electric current densities of vertically and horizontally aligned dart electrodes was quantified and different hit scenarios compared. Since fibrillation thresholds critically depend on exposed volume, the provided quantitative data are essential for risk assessment. The maximum cardiac rms current densities amounted to 7730 A m-2. Such high current densities and exposed cardiac volumes do not exclude ventricular fibrillation.

  10. Biphasic defibrillation using a single capacitor with large capacitance: reduction of peak voltages and ICD device size.

    Science.gov (United States)

    Block, M; Hammel, D; Böcker, D; Borggrefe, M; Budde, T; Isbruch, F; Scheld, H H; Breithardt, G

    1996-02-01

    The volume of current implantable cardioverter defibrillators (ICD) is not convenient for pectoral implantation. One way to reduce the size of the pulse generator is to find a more effective defibrillation pulse waveform generated from smaller volume capacitors. In a prospective randomized crossover study we compared the step-down defibrillation threshold (DFT) of a standard biphasic waveform (STD), delivered by two 250-microF capacitors connected in series with an 80% tilt, to an experimental biphasic waveform delivered by a single 450-microF capacitor with a 60% tilt. The experimental waveform delivered the same energy with a lower peak voltage and a longer duration (LVLD). Intraoperatively, in 25 patients receiving endocardial (n = 12) or endocardial-subcutaneous array (n = 13) defibrillation leads, the DFT was determined for both waveforms. Energy requirements did not differ at DFT for the STD and LVLD waveforms with the low impedance (32 +/- 4 omega) endocardial-subcutaneous array defibrillation lead system (6.4 +/- 4.4 J and 5.9 +/- 4.2 J, respectively) or increased slightly (P = 0.06) with the higher impedance (42 +/- 4 omega) endocardial lead system (10.4 +/- 4.6 J and 12.7 +/- 5.7 J, respectively). However, the voltage needed at DFT was one-third lower with the LVLD waveform than with the STD waveform for both lead systems (256 +/- 85 V vs 154 +/- 51 V and 348 +/- 76 V vs 232 +/- 54 V, respectively). Thus, a single capacitor with a large capacitance can generate a defibrillation pulse with a substantial lower peak voltage requirement without significantly increasing the energy requirements. The volume reduction in using a single capacitor can decrease ICD device size.

  11. Power nanosecond pulse shaping by means of RCD-generators with peaking circuits based on diode current breakers

    CERN Document Server

    Grekhov, I V; Korotkov, S V; Stepanyants, A L; Khristyuk, D V

    2002-01-01

    One considered the basic principles to design nanosecond region generators based on reverse-connected dynistos (RCD) with diode current breaker base output peaking circuits. Paper presents the results of experimental investigation in intense generator based on RCD, peaking pulsed transformer and high-voltage diode breaker from a set of series-connected drift diodes with abrupt reset. Generator at 1 kHz frequency commutates voltage pulses with approx 45 kV amplitude, approx 50 ns duration and approx 10 ns rise front to 25 ohm load

  12. Hardening of alloys in glow discharge with the use of pulsed electric current

    International Nuclear Information System (INIS)

    Shipko, M.N.; Pomel'nikova, A.S.; Solunin, A.M.; Solunin, M.A.

    2002-01-01

    The effect of ex/ternal pulsed electric field on the thickness of a hardened surface layer of a Nd-Fe-B system alloy during chemical heat treatment in a glow discharge is studied. The relationship is established between the hardened layer thickness and the frequency of external electric field which is verified by derived equations for the relation between electron energy and pulsed electric field frequency [ru

  13. The effect of pulsed current electrodeposition parameters of calcium phosphates coating on Ti6Al4V ELI

    Science.gov (United States)

    Sierra-Herrera, D. K.; Sandoval-Amador, A.; Montañez-Supelano, N. D.; Y Peña-Ballesteros, D.

    2017-12-01

    Pulse current electrodeposition is a technique of special interest, due to the advantages it has, like easy operation, high control in the amount, homogeneity and purity of the deposited material, and low cost. This work studies the influence of the pulsed electrodeposition parameters variation on the characteristics of calcium phosphates coatings, including the composition, crystallinity and morphology. The influence of the current density and pulse on and off time on the physicochemical properties of the obtained coatings were evaluated. The coatings were electrodeposited on Ti6Al4V using Ca(NO3)2·H2O and NH4H2PO4 with a Ca/P molar ratio of 1.67. The coatings were characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and Scanning electron microscopy (SEM). The analysis of DRX confirmed the formation of HAP. The results revealed that the variation of the current density modified the morphology of the coating. Also, the amount of material deposited increases as the off-time pulse increases, allowing the diffusion of the ions in the solution towards the working electrode.

  14. Commissioning of the long-pulse fast wave current drive antennas for DIII-D

    International Nuclear Information System (INIS)

    Baity, F.W.; Barber, G.C.; Goulding, R.H.; Hoffman, D.J.; DeGrassie, J.S.; Pinsker, R.I.; Petty, C.C.; Cary, W.

    1995-01-01

    Two new four-element fast wave current drive antennas have been installed on DIII-D. These antennas are designed for 10-s pulses at 2 MW each in the frequency range of 30 to 120 MHz. Each element comprises two poloidal segments fed in parallel in order to optimize plasma coupling at the upper end of the frequency range. The antennas are mounted on opposite sides of the vacuum vessel, in ports designated 0 degrees and 180 degrees after their toroidal angle. Each antenna array is fed by a single transmitter. The power is first split two ways by means of a 3-dB hybrid coupler, then each of these lines feeds a resonant loop connecting a pair of array elements. The power transfer during asymmetric phasing is shunted between resonant loops by a decoupler. The resonant loops are fitted with line stretchers so that multiple frequencies of operation are possible without reconfiguring the transmission line. Commissioning of these antennas has been underway since June 1994. Several deficiencies in the transmission line system were uncovered during initial vacuum conditioning, including problems with the transmission line insulators and with the drive rods for the variable elements. The former was solved by replacing the original alumina insulators, and the latter has been avoided during operation to date by positioning the tuners to avoid high voltage appearing on the drive rods. A modified design for the drive rods will be implemented before RF operations resume operation June 1995. New transmitters were procured from ABB for the new antennas and were installed in parallel with the antenna installation. During initial vacuum conditioning of the antenna in the 180 degree port a fast digital oscilloscope was used to try to pinpoint the location of arcing by a time-of-flight technique and to develop an understanding of the typical arc signature in the system

  15. Investigations of current limiting properties of the MgB2 wires subjected to pulse overcurrents in the benchtop tester

    International Nuclear Information System (INIS)

    Ye Lin; Majoros, M; Campbell, A M; Coombs, T; Harrison, S; Sargent, P; Haslett, M; Husband, M

    2007-01-01

    A laboratory scale desktop test system including a cryogenic system, an AC pulse generation system and a real time data acquisition program in LabView/DAQmx, has been developed to evaluate the quench properties of MgB 2 wires as an element in a superconducting fault current limiter under pulse overcurrents at 25 K in self-field conditions. The MgB 2 samples started from a superconducting state and demonstrated good current limiting properties characterized by a fast transition to the normal state during the first half of the cycle and a continuously limiting effect in the subsequent cycles without burnouts. The experimental and numerical simulation results on the quench behaviour indicate the feasibility of using MgB 2 for future superconducting fault current limiter (SFCL) applications

  16. Use of alternating and pulsed direct current electrified fields for zebra mussel control

    Science.gov (United States)

    Luoma, James A.; Dean, Jan C.; Severson, Todd J.; Wise, Jeremy K.; Barbour, Matthew

    2017-01-01

    Alternatives to chemicals for controlling dreissenid mussels are desirable for environmental compatibility, but few alternatives exist. Previous studies have evaluated the use of electrified fields for stunning and/or killing planktonic life stages of dreissenid mussels, however, the available literature on the use of electrified fields to control adult dreissenid mussels is limited. We evaluated the effects of sinusoidal alternating current (AC) and 20% duty cycle square-wave pulsed direct current (PDC) exposure on the survival of adult zebra mussels at water temperatures of 10, 15, and 22 °C. Peak voltage gradients of ~ 17 and 30 Vp/cm in the AC and PDC exposures, respectively, were continuously applied for 24, 48, or 72 h. Peak power densities ranged from 77,999 to 107,199 µW/cm3 in the AC exposures and 245,320 to 313,945 µW/cm3 in the PDC exposures. The peak dose ranged from 6,739 to 27,298 Joules/cm3 and 21,306 to 80,941 Joules/cm3 in the AC and PDC exposures, respectively. The applied power ranged from 16.6 to 68.9 kWh in the AC exposures and from 22.2 to 86.4 kWh in the PDC exposures. Mortality ranged from 2.7 to 92.7% in the AC exposed groups and from 24.0 to 98.7% in PDC exposed groups. Mortality increased with corresponding increases in water temperature and exposure duration, and we observed more zebra mussel mortality in the PDC exposures. Exposures conducted with AC required less of a peak dose (Joules/cm3) but more applied power (kWh) to achieve the same level of adult zebra mussel mortality as corresponding PDC exposures. The results demonstrate that 20% duty cycle square-wave PDC requires less energy than sinusoidal AC to inducing the same level of adult zebra mussel mortality.

  17. Acute Biphasic Effects of Ayahuasca.

    Science.gov (United States)

    Schenberg, Eduardo Ekman; Alexandre, João Felipe Morel; Filev, Renato; Cravo, Andre Mascioli; Sato, João Ricardo; Muthukumaraswamy, Suresh D; Yonamine, Maurício; Waguespack, Marian; Lomnicka, Izabela; Barker, Steven A; da Silveira, Dartiu Xavier

    2015-01-01

    Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG) recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8-13 Hz) after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30-50 and 50-100 Hz, respectively) between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca's chemical compounds, mostly N,N-dimethyltryptamine (DMT), harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered.

  18. Acute Biphasic Effects of Ayahuasca.

    Directory of Open Access Journals (Sweden)

    Eduardo Ekman Schenberg

    Full Text Available Ritual use of ayahuasca, an amazonian Amerindian medicine turned sacrament in syncretic religions in Brazil, is rapidly growing around the world. Because of this internationalization, a comprehensive understanding of the pharmacological mechanisms of action of the brew and the neural correlates of the modified states of consciousness it induces is important. Employing a combination of electroencephalogram (EEG recordings and quantification of ayahuasca's compounds and their metabolites in the systemic circulation we found ayahuasca to induce a biphasic effect in the brain. This effect was composed of reduced power in the alpha band (8-13 Hz after 50 minutes from ingestion of the brew and increased slow- and fast-gamma power (30-50 and 50-100 Hz, respectively between 75 and 125 minutes. Alpha power reductions were mostly located at left parieto-occipital cortex, slow-gamma power increase was observed at left centro-parieto-occipital, left fronto-temporal and right frontal cortices while fast-gamma increases were significant at left centro-parieto-occipital, left fronto-temporal, right frontal and right parieto-occipital cortices. These effects were significantly associated with circulating levels of ayahuasca's chemical compounds, mostly N,N-dimethyltryptamine (DMT, harmine, harmaline and tetrahydroharmine and some of their metabolites. An interpretation based on a cognitive and emotional framework relevant to the ritual use of ayahuasca, as well as it's potential therapeutic effects is offered.

  19. INTERACTION OF LASER RADIATION WITH MATTER. LASER PLASMA: Generation of current pulses during polarisation of air ionised by ultraviolet laser radiation

    Science.gov (United States)

    Antipov, A. A.; Losev, Leonid L.; Soskov, V. I.

    1994-10-01

    Current pulses were generated in the course of the polarisation of air ionised by ultraviolet radiation. The dependence of the current pulse duration on the air pressure had a maximum. The amplitude of the pulses depended quadratically on the intensity of the laser radiation with the wavelength of 266 nm; the amplitude increased when the pressure was reduced in the range 10-760 Torr.

  20. Ultrafast fiber lasers based on self-similar pulse evolution: a review of current progress.

    Science.gov (United States)

    Chong, Andy; Wright, Logan G; Wise, Frank W

    2015-11-01

    Self-similar fiber oscillators are a relatively new class of mode-locked lasers. In these lasers, the self-similar evolution of a chirped parabolic pulse in normally-dispersive passive, active, or dispersion-decreasing fiber (DDF) is critical. In active (gain) fiber and DDF, the novel role of local nonlinear attraction makes the oscillators fundamentally different from any mode-locked lasers considered previously. In order to reconcile the spectral and temporal expansion of a pulse in the self-similar segment with the self-consistency required by a laser cavity's periodic boundary condition, several techniques have been applied. The result is a diverse range of fiber oscillators which demonstrate the exciting new design possibilities based on the self-similar model. Here, we review recent progress on self-similar oscillators both in passive and active fiber, and extensions of self-similar evolution for surpassing the limits of rare-earth gain media. We discuss some key remaining research questions and important future directions. Self-similar oscillators are capable of exceptional performance among ultrashort pulsed fiber lasers, and may be of key interest in the development of future ultrashort pulsed fiber lasers for medical imaging applications, as well as for low-noise fiber-based frequency combs. Their uniqueness among mode-locked lasers motivates study into their properties and behaviors and raises questions about how to understand mode-locked lasers more generally.

  1. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  2. Development and application of network virtual instrument for emission spectrum of pulsed high-voltage direct current discharge

    Science.gov (United States)

    Gong, X.; Wu, Q.

    2017-12-01

    Network virtual instrument (VI) is a new development direction in current automated test. Based on LabVIEW, the software and hardware system of VI used for emission spectrum of pulsed high-voltage direct current (DC) discharge is developed and applied to investigate pulsed high-voltage DC discharge of nitrogen. By doing so, various functions are realized including real time collection of emission spectrum of nitrogen, monitoring operation state of instruments and real time analysis and processing of data. By using shared variables and DataSocket technology in LabVIEW, the network VI system based on field VI is established. The system can acquire the emission spectrum of nitrogen in the test site, monitor operation states of field instruments, realize real time face-to-face interchange of two sites, and analyze data in the far-end from the network terminal. By employing the network VI system, the staff in the two sites acquired the same emission spectrum of nitrogen and conducted the real time communication. By comparing with the previous results, it can be seen that the experimental data obtained by using the system are highly precise. This implies that the system shows reliable network stability and safety and satisfies the requirements for studying the emission spectrum of pulsed high-voltage discharge in high-precision fields or network terminals. The proposed architecture system is described and the target group gets the useful enlightenment in many fields including engineering remote users, specifically in control- and automation-related tasks.

  3. Dead time of different neutron detectors associated with a pulsed electronics with current collection

    International Nuclear Information System (INIS)

    Bacconnet, Eugene; Duchene, Jean; Duquesne, Henry; Schmitt, Andre

    1968-01-01

    After having outlined that the development of fast neutron reactor physics, notably kinetics, requires highly efficient neutron detectors and pulse measurement chains able to cope with high counting rates, the authors report the measurement of dead time of various neutron detectors which are used in the experimental study of fast neutron reactors. They present the SAITB 1 electronic measurement set, its components, its general characteristics, the protected connection between the detector and the electronics. They present and report the experiment: generalities about detector location and measurements, studied detectors (fission chambers, boron counters), and report the exploitation of the obtained results (principle, data, high-threshold counting gain) [fr

  4. WC/Co composite surface structure and nano graphite precipitate induced by high current pulsed electron beam irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hao, S.Z., E-mail: ebeam@dlut.edu.cn [Key Laboratory of Materials Modification and School of Physics and Optoelectronics Engineering, Dalian University of Technology, Dalian 116024 (China); Zhang, Y. [Key Laboratory of Materials Modification and School of Physics and Optoelectronics Engineering, Dalian University of Technology, Dalian 116024 (China); School of Materials Science and Engineering, Shenyang University of Technology, Shenyang 110870 (China); Xu, Y. [Key Laboratory of Materials Modification and School of Physics and Optoelectronics Engineering, Dalian University of Technology, Dalian 116024 (China); College of Materials Science and Engineering, Liaoning Technical University, Fuxin 123000 (China); Gey, N.; Grosdidier, T. [Université de Lorraine, Laboratoire d’Etude des Microstructures et de Mécanique des Matériaux (LEM3), CNRS UMR 7239, Ile du Saulcy, 57045 Metz (France); Université de Lorraine, Laboratoire d’Excellence on Design of Alloy Metals for Low-Mass Structure (DAMAS), Ile du Saulcy, 57045 Metz (France); Dong, C. [Key Laboratory of Materials Modification and School of Physics and Optoelectronics Engineering, Dalian University of Technology, Dalian 116024 (China); Université de Lorraine, Laboratoire d’Excellence on Design of Alloy Metals for Low-Mass Structure (DAMAS), Ile du Saulcy, 57045 Metz (France)

    2013-11-15

    High current pulsed electron beam (HCPEB) irradiation was conducted on a WC-6% Co hard alloy with accelerating voltage of 27 kV and pulse duration of 2.5 μs. The surface phase structure was examined by using glancing-angle X-ray diffraction (GAXRD), scanning electron microscope (SEM) and high resolution transmission electron microscope (HRTEM) methods. The surface tribological properties were measured. It was found that after 20 pulses of HCPEB irradiation, the surface structure of WC/Co hard alloy was modified dramatically and composed of a mixture of nano-grained WC{sub 1−x}, Co{sub 3}W{sub 9}C{sub 4}, Co{sub 3}W{sub 3}C phases and graphite precipitate domains ∼50 nm. The friction coefficient of modified surface decreased to ∼0.38 from 0.6 of the initial state, and the wear rate reduced from 8.4 × 10{sup −5} mm{sup 3}/min to 6.3 × 10{sup −6} mm{sup 3}/min, showing a significant self-lubricating effect.

  5. Dilution and Ferrite Number Prediction in Pulsed Current Cladding of Super-Duplex Stainless Steel Using RSM

    Science.gov (United States)

    Eghlimi, Abbas; Shamanian, Morteza; Raeissi, Keyvan

    2013-12-01

    Super-duplex stainless steels have an excellent combination of mechanical properties and corrosion resistance at relatively low temperatures and can be used as a coating to improve the corrosion and wear resistance of low carbon and low alloy steels. Such coatings can be produced using weld cladding. In this study, pulsed current gas tungsten arc cladding process was utilized to deposit super-duplex stainless steel on high strength low alloy steel substrates. In such claddings, it is essential to understand how the dilution affects the composition and ferrite number of super-duplex stainless steel layer in order to be able to estimate its corrosion resistance and mechanical properties. In the current study, the effect of pulsed current gas tungsten arc cladding process parameters on the dilution and ferrite number of super-duplex stainless steel clad layer was investigated by applying response surface methodology. The validity of the proposed models was investigated by using quadratic regression models and analysis of variance. The results showed an inverse relationship between dilution and ferrite number. They also showed that increasing the heat input decreases the ferrite number. The proposed mathematical models are useful for predicting and controlling the ferrite number within an acceptable range for super-duplex stainless steel cladding.

  6. Metallurgical characterization of pulsed current gas tungsten arc, friction stir and laser beam welded AZ31B magnesium alloy joints

    International Nuclear Information System (INIS)

    Padmanaban, G.; Balasubramanian, V.

    2011-01-01

    This paper reports the influences of welding processes such as friction stir welding (FSW), laser beam welding (LBW) and pulsed current gas tungsten arc welding (PCGTAW) on mechanical and metallurgical properties of AZ31B magnesium alloy. Optical microscopy, scanning electron microscopy, transmission electron microscopy and X-Ray diffraction technique were used to evaluate the metallurgical characteristics of welded joints. LBW joints exhibited superior tensile properties compared to FSW and PCGTAW joints due to the formation of finer grains in weld region, higher fusion zone hardness, the absence of heat affected zone, presence of uniformly distributed finer precipitates in weld region.

  7. Behavior of impurity ion velocities during the pulsed poloidal current drive in the Madison symmetric torus reversed-field pinch

    International Nuclear Information System (INIS)

    Sakakita, Hajime; Craig, Darren; Anderson, Jay K.; Chapman, Brett E.; Den-Hartog, Daniel J.; Prager, Stewart C.; Biewer, Ted M.; Terry, Stephen D.

    2003-01-01

    We report on passive measurements of impurity ion velocities during the pulsed poloidal current drive (PPCD) in the Madison Symmetric Torus reversed-field pinch. During PPCD, the electron temperature increased and a sudden reduction of magnetic fluctuations was observed. For this change, we have studied whether plasma velocity is affected. Plasma rotation is observed to decrease during PPCD. From measurements of line intensities for several impurities at 10 poloidal chords, it is found that the impurity line emission shifts outward. The ion temperature of impurities is reasonably connected to that measured by charge exchange recombination spectroscopy from core to edge. (author)

  8. Current regimen of pulse therapy for pemphigus: Minor modifications, improved results

    Directory of Open Access Journals (Sweden)

    Pasricha J

    2008-01-01

    Full Text Available Background: If administered properly, dexamethasone cyclophosphamide pulse (DCP therapy has the potential to effect lifelong recovery from pemphigus. Aims: The objective of this paper is to highlight various parameters of DCP therapy and also, to report the effects of a few modifications in the regimen. Methods: An analysis of 123 patients treated with the DCP/DP regimen over a period of five years (1998 to 2002 is presented here. Seventeen patients who did not start/continue the treatment and three patients who died during the treatment have been excluded from the analysis. Twenty patients who had not yet started families were given only dexamethasone pulses (DPs while 103 patients received DCPs. Low dose (50 mg/day cyclophosphamide was used as in the standard regimen. The three modifications introduced into the regimen were: (1 an additional daily dose of oral betamethasone sufficient to control the disease activity during phase I, which was progressively tapered off completely as the patient recovered, (2 use of systemic antibiotics if the patient had skin lesions, and oral anti-candida drugs if the patient had oral ulcers until complete healing, and (3 insistence on thorough cleaning of the skin and scalp with a normal soap and shampoo, and proper maintenance of oral hygiene in spite of skin/mucosal lesions. The regimen consisted of DCP/DP repeated in exactly 28-day cycles, along with 50 mg cyclophosphamide per day, insistence on completing the treatment and avoiding irregular pulses in all patients. The number of DCPs/DPs during phase I varied in different patients depending upon the dose of betamethasone used and the rate of recovery, but phase II (nine DCPs/DPs in exactly 28-day cycles along with 50 mg cyclophosphamide per day and phase III (only 50 mg cyclophosphamide per day was fixed at nine months each. This was followed by posttreatment follow-up (phase IV. Results: At present, all the patients are in complete remission. The

  9. Electrochemical deposition of the cobalt nanostructure by double template and pulse current methods

    International Nuclear Information System (INIS)

    Foyet, A.; Hauser, A.; Schaefer, W.

    2007-01-01

    An electrochemical pulse method and the principles of the so-called double template deposition have been developed to prepare a cobalt nanomaterial. Atomic force microscopy (AFM) analysis reveal a material with double structure; fibers that grow from the bottom of the pores in the aluminum oxide membrane present many subdivision due to the lyotropic liquid crystal template. The small-scale images show parallel lines with regular periodicity formed by cobalt on the surface of the Al 2 O 3 /Al working electrode. The distance between the two consecutive lines is about 10 nm, this value is close to the diameter of the column of liquid crystal. Depending on the experimental condition, the axis of the column of liquid crystal can be parallel to the plan of the electrode surface

  10. High precision electron beam diagnostic system for high current long pulse beams

    International Nuclear Information System (INIS)

    Chen, Y J; Fessenden, T; Holmes, C; Nelson, S D; Selchow, N.

    1999-01-01

    As part of the effort to develop a multi-axis electron beam transport system using stripline kicker technology for DARHT II applications, it is necessary to precisely determine the position and extent of long high energy beams (6-40 MeV, 1-4 kA, 2 microseconds) for accurate position control. The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (<20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt measurements performed using capacitive pick-off probes. Likewise, transmission line traveling wave probes have problems with multi-bounce effects due to these longer pulse widths. Finally, the high energy densities experienced in these applications distort typical foil beam position measurements

  11. Current and future prospects for the use of pulsed electric field in the meat industry.

    Science.gov (United States)

    Bhat, Zuhaib F; Morton, James D; Mason, Susan L; Bekhit, Alaa El-Din A

    2018-02-02

    Pulsed electric field (PEF) is a novel non-thermal technology that has recently attracted the attention of meat scientists and technologists due to its ability to modify membrane structure and enhance mass transfer. Several studies have confirmed the potential of pulsed electric field for improving meat tenderness in both pre-rigor and post-rigor muscles during aging. However, there is a high degree of variability between studies and the underlying mechanisms are not clearly understood. While some studies have suggested physical disruption as the main cause of PEF induced tenderness, enzymatic nature of the tenderization seems to be the most plausible mechanism. Several studies have suggested the potential of PEF to mediate the tenderization process due to its membrane altering properties causing early release of calcium ions and early activation of the calpain proteases. However, experimental research is yet to confirm this postulation. Recent studies have also reported increased post-mortem proteolysis in PEF treated muscles during aging. PEF has also been reported to accelerate curing, enhance drying and reduce the numbers of both pathogens and spoilage organisms in meat, although that demands intense processing conditions. While tenderization, meat safety and accelerated curing appears to be the areas where PEF could provide attractive options in meat processing, further research is required before the application of PEF becomes a commercial reality in the meat industry. It needs to deal with carcasses which vary biochemically and in composition (muscle, fat, and bones). This review critically evaluates the published reports on the topic with the aim of reaching a clear understanding of the possible applications of PEF in the meat sector in addition to providing some insight on critical issues that need to be addressed for the technology to be a practical option for the meat industry.

  12. Optimization of Experimental Conditions of the Pulsed Current GTAW Parameters for Mechanical Properties of SDSS UNS S32760 Welds Based on the Taguchi Design Method

    Science.gov (United States)

    Yousefieh, M.; Shamanian, M.; Saatchi, A.

    2012-09-01

    Taguchi design method with L9 orthogonal array was implemented to optimize the pulsed current gas tungsten arc welding parameters for the hardness and the toughness of super duplex stainless steel (SDSS, UNS S32760) welds. In this regard, the hardness and the toughness were considered as performance characteristics. Pulse current, background current, % on time, and pulse frequency were chosen as main parameters. Each parameter was varied at three different levels. As a result of pooled analysis of variance, the pulse current is found to be the most significant factor for both the hardness and the toughness of SDSS welds by percentage contribution of 71.81 for hardness and 78.18 for toughness. The % on time (21.99%) and the background current (17.81%) had also the next most significant effect on the hardness and the toughness, respectively. The optimum conditions within the selected parameter values for hardness were found as the first level of pulse current (100 A), third level of background current (70 A), first level of % on time (40%), and first level of pulse frequency (1 Hz), while they were found as the second level of pulse current (120 A), second level of background current (60 A), second level of % on time (60%), and third level of pulse frequency (5 Hz) for toughness. The Taguchi method was found to be a promising tool to obtain the optimum conditions for such studies. Finally, in order to verify experimental results, confirmation tests were carried out at optimum working conditions. Under these conditions, there were good agreements between the predicted and the experimental results for the both hardness and toughness.

  13. Biphasic Insulin Analogues in Type 2 Diabetes: Expert Panel Recommendations

    Directory of Open Access Journals (Sweden)

    Sema Akalın

    2011-09-01

    Full Text Available Recently, the prevalence of type 2 diabetes has reached pandemic levels all over the world, and the problem is still growing. Type 2 diabetes is a progressive disease, in which insulin resistance and decrease in beta cell function accompany obesity. Early disorder, which ensues in clinical progression of the disease, is the defect of early phase insulin secretion. Patients have already lost approximately half of their beta cell reserve at the time of diagnosis. Aims of type 2 diabetes treatment are to eliminate hyperglycemia caused by insufficient insulin secretion and/or insulin resistance, to slow down beta cell destruction/depletion, to improve concomitant metabolic problems and to prevent complications. In treatment algorithms, insulin is evaluated as a replacement therapy at the following stage after life style changes (medical nutrition therapy, exercise and oral anti-diabetic drugs (OADs options. Since beta cell depletion is present at initial stages of the disease, it transforms insulin therapy into an earlier approach in treatment stages. Premixed insulin forms are one of the proposed treatment options in patients with hyperglycemia that is not controlled by OADs. These types of insulins are developed to meet both basal and postprandial insulin requirements of patients. Currently, premixed human insulin forms are replaced by analogue insulin forms, which can mimic the physiological secretion in more acceptable manner. Biphasic analogue insulin is one of the readily available pre-mixed analogue insulin forms, an example of this, Biphasic Insulin aspart 30 which is the one of the premixed analoge insulin forms, contains 30% insulin aspart and 70% protaminated insulin aspart. Consensus recommending the individualized approach in insulin therapy implies that physicians should have more detailed information about the use of different insulin forms. Although a global consensus report about initiation, titration and intensification and the use

  14. Transient interaction model of electromagnetic field generated by lightning current pulses and human body

    International Nuclear Information System (INIS)

    Iváncsy, T; Kiss, I; Tamus, Z Á; Szücs, L

    2015-01-01

    The lightning current generates time-varying magnetic field near the down-conductor and the down-conductors are mounted on the wall of the buildings where residential places might be situated. It is well known that the rapidly changing magnetic fields can generate dangerous eddy currents in the human body.The higher duration and gradient of the magnetic field can cause potentially life threatening cardiac stimulation. The coupling mechanism between the electromagnetic field and the human body is based on a well-known physical phenomena (e.g. Faradays law of induction). However, the calculation of the induced current is very complicated because the shape of the organs is complex and the determination of the material properties of living tissues is difficult, as well. Our previous study revealed that the cardiac stimulation is independent of the rising time of the lightning current and only the peak of the current counts.In this study, the authors introduce an improved model of the interaction of electromagnetic fields of lighting current near down-conductor and human body. Our previous models are based on the quasi stationer field calculations, the new improved model is a transient model. This is because the magnetic field around the down-conductor and in the human body can be determined more precisely, therefore the dangerous currents in the body can be estimated. (paper)

  15. Spatio-temporal characterization of the multiple current pulse regime of diffuse barrier discharges in helium with nitrogen admixtures

    Science.gov (United States)

    Bogaczyk, Marc; Tschiersch, Robert; Nemschokmichal, Sebastian; Meichsner, Jürgen

    2017-10-01

    This work reports on the spatio-temporal characterization of the multiple current pulse regime of diffuse barrier discharges driven by sine-wave feeding voltage at a frequency of 2~kHz in helium with small nitrogen admixtures. The discharge gap of 3~mm is bounded by glass plates on both plane electrodes. Priority is given to the lateral discharge inhomogeneities, underlying volume- and surface-memory effects, and the breakdown mechanism. Therefore, relevant processes in the discharge volume and on the dielectric surfaces were investigated by ICCD camera imaging and optical emission spectroscopy in combination with electrical measurements and surface charge diagnostics using the electro-optic Pockels effect of a bismuth silicon oxide crystal. The number of current pulses per half-cycle of the sine-wave voltage rises with increasing nitrogen admixture to helium due to the predominant role of the Penning ionization. Here, the transition from the first glow-like breakdown to the last Townsend-like breakdown is favored by residual species from the former breakdowns which enhance the secondary electron emission during the pre-phase of the later breakdowns. Moreover, the surface charge measurements reveal that the consecutive breakdowns occur alternately at central and peripheral regions on the electrode surface. These spatial inhomogeneities are conserved by the surface charge memory effect as pointed out by the recalculated spatio-temporal development of the gap voltage.

  16. Strengthening effect of nano-scaled precipitates in Ta alloying layer induced by high current pulsed electron beam

    International Nuclear Information System (INIS)

    Tang, Guangze; Luo, Dian; Fan, Guohua; Ma, Xinxin; Wang, Liqin

    2017-01-01

    Highlights: • Ta alloying layer are fabricated by magnetron sputtering and high current pulsed electron beam. • Nano-scaled TaC precipitates forms within the δ-Fe grain after tempering treatment. • The mean diameter of TaC particles is about 5–8 nm. • The hardness of alloying layer increased by over 50% after formation of nano-scaled TaC particle. - Abstract: In this study, the combination of magnetron sputtering and high current pulsed electron beam are used for surface alloying treatment of Ta film on high speed steel. And the Ta alloying layer is about 6 μm. After tempering treatment, TaC phase forms in Ta alloying layer when the treated temperature is over 823 K. Through the TEM and HRTEM observation, a large amount of nano-scaled precipitates (mean diameter 5–8 nm) form within the δ-Fe grain in Ta alloying layer after tempering treatment and these nano-scaled precipitates are confirmed as TaC particles, which contribute to the strengthening effect of the surface alloying layer. The hardness of tempered alloying layer can reach to 18.1 GPa when the treated temperature is 823 K which increase by 50% comparing with the untreated steel sample before surface alloying treatment.

  17. Strengthening effect of nano-scaled precipitates in Ta alloying layer induced by high current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Guangze; Luo, Dian; Fan, Guohua [School of Material Science & Engineering, Harbin Institute of Technology, Harbin 150001 (China); Ma, Xinxin, E-mail: maxin@hit.edu.cn [State Key Laboratory of Advanced Welding and Joining, Harbin Institute of Technology, Harbin 150001 (China); Wang, Liqin [School of Mechatronics Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2017-05-01

    Highlights: • Ta alloying layer are fabricated by magnetron sputtering and high current pulsed electron beam. • Nano-scaled TaC precipitates forms within the δ-Fe grain after tempering treatment. • The mean diameter of TaC particles is about 5–8 nm. • The hardness of alloying layer increased by over 50% after formation of nano-scaled TaC particle. - Abstract: In this study, the combination of magnetron sputtering and high current pulsed electron beam are used for surface alloying treatment of Ta film on high speed steel. And the Ta alloying layer is about 6 μm. After tempering treatment, TaC phase forms in Ta alloying layer when the treated temperature is over 823 K. Through the TEM and HRTEM observation, a large amount of nano-scaled precipitates (mean diameter 5–8 nm) form within the δ-Fe grain in Ta alloying layer after tempering treatment and these nano-scaled precipitates are confirmed as TaC particles, which contribute to the strengthening effect of the surface alloying layer. The hardness of tempered alloying layer can reach to 18.1 GPa when the treated temperature is 823 K which increase by 50% comparing with the untreated steel sample before surface alloying treatment.

  18. Effect of Inductive Coil Geometry and Current Sheet Trajectory of a Conical Theta Pinch Pulsed Inductive Plasma Accelerator

    Science.gov (United States)

    Hallock, Ashley K.; Polzin, Kurt A.; Bonds, Kevin W.; Emsellem, Gregory D.

    2011-01-01

    Results are presented demonstrating the e ect of inductive coil geometry and current sheet trajectory on the exhaust velocity of propellant in conical theta pinch pulsed induc- tive plasma accelerators. The electromagnetic coupling between the inductive coil of the accelerator and a plasma current sheet is simulated, substituting a conical copper frustum for the plasma. The variation of system inductance as a function of plasma position is obtained by displacing the simulated current sheet from the coil while measuring the total inductance of the coil. Four coils of differing geometries were employed, and the total inductance of each coil was measured as a function of the axial displacement of two sep- arate copper frusta both having the same cone angle and length as the coil but with one compressed to a smaller size relative to the coil. The measured relationship between total coil inductance and current sheet position closes a dynamical circuit model that is used to calculate the resulting current sheet velocity for various coil and current sheet con gura- tions. The results of this model, which neglects the pinching contribution to thrust, radial propellant con nement, and plume divergence, indicate that in a conical theta pinch ge- ometry current sheet pinching is detrimental to thruster performance, reducing the kinetic energy of the exhausting propellant by up to 50% (at the upper bound for the parameter range of the study). The decrease in exhaust velocity was larger for coils and simulated current sheets of smaller half cone angles. An upper bound for the pinching contribution to thrust is estimated for typical operating parameters. Measurements of coil inductance for three di erent current sheet pinching conditions are used to estimate the magnetic pressure as a function of current sheet radial compression. The gas-dynamic contribution to axial acceleration is also estimated and shown to not compensate for the decrease in axial electromagnetic acceleration

  19. Long pulse FRC sustainment with enhanced edge driven rotating magnetic field current drive

    International Nuclear Information System (INIS)

    Hoffman, A.L.; Guo, H.Y.; Miller, K.E.; Milroy, R.D.

    2005-01-01

    FRCs have been formed and sustained for up to 50 normal flux decay times by Rotating Magnetic Fields (RMF) in the TCS experiment. For these longer pulse times a new phenomenon has been observed: switching to a higher performance mode delineated by shallower RMF penetration, higher ratios of generated poloidal to RMF drive field, and lower overall plasma resistivity. This global data is not explainable by previous RMF theory based on uniform electron rotational velocities or by numerical calculations based on uniform plasma resistivity, but agrees in many respects with new calculations made using strongly varying resistivity profiles. In order to more realistically model RMF driven FRCs with such non-uniform resistivity profiles, a double rigid rotor model has been developed with separate inner and outer electron rotational velocities and resistivities. The results of this modeling suggest that the RMF drive results in very high resistivity in a narrow edge layer, and that the higher performance mode is characterized by a sharp reduction in resistivity over the bulk of the FRC. (author)

  20. Improved corrosion behavior of nanocrystalline zinc produced by pulse-current electrodeposition

    International Nuclear Information System (INIS)

    Youssef, Kh.M.S.; Koch, C.C.; Fedkiw, P.S.

    2004-01-01

    Pulse electrodeposition was used to produce nanocrystalline (nc) zinc from zinc chloride electrolyte with polyacrylamide and thiourea as additives. Field emission scanning electron microscopy (FESEM) was used to study the grain size and surface morphology of the deposits and X-ray diffraction was used to examine their preferred orientation. Corrosion behavior of the electrodeposited nc zinc in comparison with electrogalvanized (EG) steel in de-aerated 0.5 N NaOH solution was studied using potentiodynamic polarization and impedance measurements. A scanning electron microscope (SEM) was used to characterize the surface morphology of the EG steel before corrosion testing. Surface morphologies of nc zinc deposits and EG steel were also studied after potentiondynamic polarization by SEM. Nanocrystalline zinc (56 nm) with random orientation was produced. The estimated corrosion rate of nc zinc was found to be about 60% lower than that of EG steel, 90 and 229 μA/cm 2 , respectively. The surface morphology of corroded nc zinc was characterized by discrete etch pits, however, uniform corrosion was obtained after potentiodynamic polarization of EG steel. The passive film formed on the nc zinc surface seems to be a dominating factor for the corrosion behavior observed

  1. A high current sinusoidal pulse generator for the diluter magnets of the LHC beam dump system

    CERN Document Server

    Vossenberg, Eugène B; Ducimetière, L; Schröder, G H

    2000-01-01

    CERN is constructing the Large Hadron Collider (LHC), a superconducting accelerator that will collide protons at a center of mass energy of 14 TeV. The two colliding beams will each store an energy of up to 540 MJ, which must be safely deposited within one beam revolution of 89 mu s on two external absorbers located about 700 m from the extraction points at the end of dedicated extraction tunnels. To avoid evaporation of the graphite absorber material by the very high energy density of the incident beams, the deposition area of the beams on the absorber front face will be increased. This is done by a pair of sinusoidally powered orthogonal magnet systems producing approximately an e-shape figure of about 35 mm diameter, with a minimum velocity of 10 mm/ mu s during the dumping process. The pulse generators of the horizontally and vertically deflecting diluter magnets are composed of capacitor banks, discharged by stacks of solid state closing switches. They are connected to the magnets by 28 m long low induct...

  2. Propagation of a pulse of coherent current near the barrier in the metal-insulator-metal junction

    Science.gov (United States)

    Nagae, Moichiro

    1982-11-01

    A time- and position-dependent electric current in the metal region in response to a step input voltage is calculated on the basis of linear-response theory. The unperturbed potential of the barrier of a biased junction is assumed to be of a square type. A complete set of eigenstates of the Hamiltonian having the unperturbed potential field of the barrier is taken as a basic orthonormal set of the electron system. Such eigenstates contain the electron waves incident on the barrier both from the left metal region and from the right metal region. The responses of the flows of electrons incident from the right and left electrodes are given by analytical integral expressions on a complex plane. Here the transient coherent current (TCC) near the barrier in the metal region is calculated and it is far greater than the usual steady incoherent current (SIC) until the TCC decays by scattering. It is found that such a TCC propagates like a nonoscillatory pulse at the Fermi velocity from the barriermetal interface toward the other end of the metal region. The height of the pulse decreases in inverse proportion to time or distance until it begins to decay by scattering. A simple formula for this current is obtained. The TCC is caused by the strong perturbed electric field in the barrier, which directly acts upon the electrons penetrating into the barrier. The TCC is described in terms of successive propagations of the displacement of the electronic charge. This displacement and the space charge associated with the TCC are also formulated simply. The TCC can completely disturb a signal carried by the SIC near the barrier. The time delay in detecting the signal is discussed. A specific experiment to detect the TCC is also proposed.

  3. High-current-density electrodeposition using pulsed and constant currents to produce thick CoPt magnetic films on silicon substrates

    Science.gov (United States)

    Ewing, Jacob; Wang, Yuzheng; Arnold, David P.

    2018-05-01

    This paper investigates methods for electroplating thick (>20 μm), high-coercivity CoPt films using high current densities (up to 1 A/cm2) and elevated bath temperatures (70 °C). Correlations are made tying current-density and temperature process parameters with plating rate, elemental ratio and magnetic properties of the deposited CoPt films. It also investigates how pulsed currents can increase the plating rate and film to substrate adhesion. Using 500 mA/cm2 and constant current, high-quality, dense CoPt films were successfully electroplated up to 20 μm thick in 1 hr on silicon substrates (0.35 μm/min plating rate). After standard thermal treatment (675°C, 30 min) to achieve the ordered L10 crystalline phase, strong magnetic properties were measured: coercivities up 850 kA/m, remanences >0.5 T, and maximum energy products up to 46 kJ/m3.

  4. Beat wave current drive with intense pulsed free-electron lasers

    International Nuclear Information System (INIS)

    Cohen, B.I.; Cohen, R.H.; Logan, B.G.; McCay Nevins, W.; Smith, G.R.; Kluge, A.V.; Kritz, A.H.

    1988-01-01

    High power free-electron lasers make possible new methods for driving current in toroidal devices with electromagnetic waves. Earlier considerations of beat wave current drive are applied to a hot magnetized plasma and an arbitrary beat wave. Here the beating of two electromagnetic waves resonantly excites a low frequency beat wave that accelerates and heats electrons and leads to a current. The absolute current drive efficiency depends non-linearly on the two pump wave intensities and is constrained by the Manley-Rowe relations. Accessibility at high plasma densities is not a difficulty, but a degree of frequency tunability of the wave sources is required. Particle simulations indicate that there is a good coupling to an electron velocity tail for a Langmuir beat wave with a phase velocity 1.5 to 3 times (T e /m e ) 1/2 , so that all of the high frequency wave source is absorbed and the beat wave damps completely on the electrons. A novel diagnostic, based on an analytical solution for the linearized Fokker-Planck equation describing electron scattering and slowing down, is added to the particle code. This permits the computation of the current drive efficiency, including both the non-linear beat wave coupling and the collisional relaxation of the electron distribution. A realistic scenario for a beat wave current drive experiment in the Livermore Microwave Tokamak Experiment is calculated using the TORAY toroidal ray tracing code, and the scaling to an engineering test reactor plasma is described. (author). 23 refs, 8 figs

  5. Predictive Pulse Pattern Current Modulation Scheme for Harmonic Reduction in Three-Phase Multidrive Systems

    DEFF Research Database (Denmark)

    Davari, Pooya; Yang, Yongheng; Zare, Firuz

    2016-01-01

    at the rectification stage to synthesize sinusoidal input currents. The input voltage sensing is avoided in order to minimize the number of required sensors, and the grid synchronization also has been implemented based on a common Phase-Locked-Loop (PLL) using the DC-link capacitor voltage ripple. Experimental results...

  6. Inductance calculation of multiconductor high-current transmission lines for pulsed power supplies

    International Nuclear Information System (INIS)

    Nudelman, A.; Fromm, N.

    1983-01-01

    For fast-switched high current power supplies the precise value of line inductance has to be determined at the design stage. This paper offers an algorithm and computer program for inductance calculation of multiconductor cables. The method renders best results for symmetrical wire configurations. Listed are some limitations concerning result accuracy related to wire configuration and wire number

  7. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    -level buck-boost CSIs. Next by observing the hidden current charging path during inductive charging interval under APOD modulation, it is noted that the buck-boost five-level CSI can then be further modified with lesser active component without degrading output performance. To verify the theoretical findings...

  8. Metal separations using aqueous biphasic partitioning systems

    International Nuclear Information System (INIS)

    Chaiko, D.J.; Zaslavsky, B.; Rollins, A.N.; Vojta, Y.; Gartelmann, J.; Mego, W.

    1996-01-01

    Aqueous biphasic extraction (ABE) processes offer the potential for low-cost, highly selective separations. This countercurrent extraction technique involves selective partitioning of either dissolved solutes or ultrafine particulates between two immiscible aqueous phases. The extraction systems that the authors have studied are generated by combining an aqueous salt solution with an aqueous polymer solution. They have examined a wide range of applications for ABE, including the treatment of solid and liquid nuclear wastes, decontamination of soils, and processing of mineral ores. They have also conducted fundamental studies of solution microstructure using small angle neutron scattering (SANS). In this report they review the physicochemical fundamentals of aqueous biphase formation and discuss the development and scaleup of ABE processes for environmental remediation

  9. Biphase sinusoidal oscillator based on negative resistor.

    Science.gov (United States)

    Bayard, Jean

    2010-06-01

    This paper describes a biphase sinusoidal generator which provides two signals: v(ref)=V(M) sin(omegat) and v(out)=V(M) sin(omegat+DeltaPhi), where DeltaPhi is in the range 0, pi/2 or -pi/2, 0 and is not dependent on the frequency value. It is based on a negative resistor and it requires very few components. SPICE simulations and measurements on an experimental setup confirm the theoretical analysis.

  10. Understanding the molecular mechanism of pulse current charging for stable lithium-metal batteries

    OpenAIRE

    Li, Qi; Tan, Shen; Li, Linlin; Lu, Yingying; He, Yi

    2017-01-01

    High energy and safe electrochemical storage are critical components in multiple emerging fields of technologies. Rechargeable lithium-metal batteries are considered to be promising alternatives for current lithium-ion batteries, leading to as much as a 10-fold improvement in anode storage capacity (from 372 to 3860 mAh g?1). One of the major challenges for commercializing lithium-metal batteries is the reliability and safety issue, which is often associated with uneven lithium electrodeposit...

  11. Neutron measurements in deuterated palladium cathodes subjected to pulsed electrolytic currents

    International Nuclear Information System (INIS)

    Granada, J.R.; Mayer, R.E.; Guido, G.; Florido, P.C.; Patino, N.E.; Gillette, V.H.; Sobehart, L.; Gomez, S.; Larreteguy, A.; Universidad Nacional de Cuyo, San Carlos de Bariloche

    1989-01-01

    We report on neutron measurements performed on electrolytic cells using a high efficiency (22%) detection system in combination with a procedure involving a non-stationary current through the cell's circuit. Under these conditions, neutron production was observed in cells containing LiH dissolved in heavy water with a Palladium cathode. Characteristic patterns showing one or two bumps were obtained in a repeatable fashion, depending on the previous charging history of the cathode. (orig.)

  12. Applications of ionic liquids in biphasic separation: Aqueous biphasic systems and liquid-liquid equilibria.

    Science.gov (United States)

    Shukla, Shashi Kant; Pandey, Shubha; Pandey, Siddharth

    2017-10-10

    Ionic liquids (ILs) have been receiving much attention in many fields of analytical chemistry because of their various interesting properties which distinguish them from volatile organic compounds. They offer both directional and non-directional forces towards a solute molecule and therefore act as excellent solvents for a wide range of polar and non-polar compounds. Because of the presence of various possible interactions, ILs easily undergo biphasic separation with water and other less polar/non-polar organic solvents. Their ability to create biphasic splitting makes them a promising candidate for liquid-liquid separation processes, such as aqueous biphasic systems and liquid-liquid equilibria. Various aspects of ILs in these separation methods are discussed in view of the origin of physical forces responsible for the biphasic interactions, the effect of structural components, temperature, pressure, pH and additives. The specific advantages of using ILs in aqueous biphasic systems and liquid-liquid equilibria in binary and ternary systems are discussed with a view to defining their future role in separation processes by giving major emphasis on developing non-toxic ILs with physical and solution properties tailored to the needs of specific sample preparation techniques. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. PULSE GENERATOR

    Science.gov (United States)

    Roeschke, C.W.

    1957-09-24

    An improvement in pulse generators is described by which there are produced pulses of a duration from about 1 to 10 microseconds with a truly flat top and extremely rapid rise and fall. The pulses are produced by triggering from a separate input or by modifying the current to operate as a free-running pulse generator. In its broad aspect, the disclosed pulse generator comprises a first tube with an anode capacitor and grid circuit which controls the firing; a second tube series connected in the cathode circuit of the first tube such that discharge of the first tube places a voltage across it as the leading edge of the desired pulse; and an integrator circuit from the plate across the grid of the second tube to control the discharge time of the second tube, determining the pulse length.

  14. Ligand modification for mono- and biphasic oxosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Haerter, P.; Herrmann, W.A.; Baskakov, D. [Technische Univ. Muenchen (Germany). Dept. Chemie

    2006-07-01

    The use of aqueous/organic biphasic systems has attracted huge interest in catalytic reactions by transition metal complexes. [1,2,3] The biphasic systems have benefits in catalyst separation and recycling, and the reduction or elimination of organic solvents is also advantageous for the development of economical and environmentally friendly processes. The key for such biphasic catalysis is the use of water soluble phosphines as ligands. Since the launch of the commercial propylene hydroformylation process by Ruhrchemie/Rhone-Poulenc, sulfonated ligands such as TPPTS (1), and BINAS (2) have been widely used as ligands in hydroformylation, hydrogenation and related reactions catalyzed by transition metals. One of the draw backs of ligands 1 and 2 are corrosive production conditions and therefore unfavorable costs. With the synthesis of aminoacid based trishydroxymethylphosphine derivatives (THMP-aminoacid) we introduce to our knowledge a new group of water soluble and cheap to produce ligands [8]. The properties of catalysts based on these compounds in the hydroformylation reaction of propene are discussed in comparison to normally used catalyst systems. In a second part the performance of catalysts containing NHC-ligands in the hydroformylation of 1-octene is discussed [9]. These investigations show, that the activity can be influenced by the electron donating ability of the NHC ligand. Sterical variations on the NHC ligands have no effect on the selectivity performance of the the catalysts. (orig.)

  15. Description of current pulses induced by heavy ions in silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Parlog, M. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); National Institute for Physics and Nuclear Engineering, RO-76900 Bucharest-Magurele (Romania); LPC, CNRS/IN2P3, ENSICAEN, Universite de Caen, F-14050 Caen Cedex (France); Hamrita, H. [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France); CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, F-91191 Gif-sur-Yvette Cedex (France); Borderie, B., E-mail: borderie@ipno.in2p3.f [Institut de Physique Nucleaire, CNRS/IN2P3, Universite Paris-Sud 11, F-91406 Orsay Cedex (France)

    2010-02-01

    The polarization of the electron-hole pairs induced by 80 MeV {sup 12}C ions in a silicon detector was considered and connected to the relative dielectric permittivity. The dissociation of pairs was supposed to take place with a constant probability in a time unit. The exact coordinate dependence of the modified electric field, inside and outside the ion range, was found as the solution of the one-dimensional Maxwell's equation for the electric field in this inhomogeneous medium. The improvement of the current signal simulation with that time-dependent treatment is encouraging, as compared to a prompt carrier collection in an undisturbed electric field.

  16. Fabrication and Mechanical Properties of Nanostructured TiC-TiAl by the Pulsed Current Activated Sintering

    International Nuclear Information System (INIS)

    Kwak, Bong-Won; Shon, In-Jin; Kim, Byung-Su; Yoon, Jin-Kook; Hong, Kyung-Tae

    2016-01-01

    TiC-Co or TiC-Ni hard materials have been used for cutting tools. However, the high cost and the low hardness of Ni or Co, and the low corrosion resistance of the TiC-Ni and TiC-Co cermets have generated interest in recent years in using them as alternative binder phases. In this study, TiAl was used as a novel binder and consolidated by the pulsed current activated sintering(PCAS) method. Nanopowders of TiC and TiAl were fabricated using high energy ball milling. Highly dense TiC-TiAl hard materials with a relative density of up to 99.5% were sintered within three min by PCAS. Not only the hardness but also the fracture toughness of the TiC-10 vol%TiAl were better than those of TiC-10 vol%Ni or TiC-10 vol%Co.

  17. Feasibility study of current pulse induced 2-bit/4-state multilevel programming in phase-change memory

    Science.gov (United States)

    Liu, Yan; Fan, Xi; Chen, Houpeng; Wang, Yueqing; Liu, Bo; Song, Zhitang; Feng, Songlin

    2017-08-01

    In this brief, multilevel data storage for phase-change memory (PCM) has attracted more attention in the memory market to implement high capacity memory system and reduce cost-per-bit. In this work, we present a universal programing method of SET stair-case current pulse in PCM cells, which can exploit the optimum programing scheme to achieve 2-bit/ 4state resistance-level with equal logarithm interval. SET stair-case waveform can be optimized by TCAD real time simulation to realize multilevel data storage efficiently in an arbitrary phase change material. Experimental results from 1 k-bit PCM test-chip have validated the proposed multilevel programing scheme. This multilevel programming scheme has improved the information storage density, robustness of resistance-level, energy efficient and avoiding process complexity.

  18. Isotopic identification using Pulse Shape Analysis of current signals from silicon detectors: Recent results from the FAZIA collaboration

    International Nuclear Information System (INIS)

    Pastore, G.; Gruyer, D.; Ottanelli, P.; Le Neindre, N.; Pasquali, G.; Alba, R.; Barlini, S.; Bini, M.; Bonnet, E.; Borderie, B.; Bougault, R.; Bruno, M.; Casini, G.; Chbihi, A.

    2017-01-01

    The FAZIA apparatus exploits Pulse Shape Analysis (PSA) to identify nuclear fragments stopped in the first layer of a Silicon-Silicon-CsI(Tl) detector telescope. In this work, for the first time, we show that the isotopes of fragments having atomic number as high as Z∼20 can be identified. Such a remarkable result has been obtained thanks to a careful construction of the Si detectors and to the use of low noise and high performance digitizing electronics. Moreover, optimized PSA algorithms are needed. This work deals with the choice of the best algorithm for PSA of current signals. A smoothing spline algorithm is demonstrated to give optimal results without requiring too much computational resources.

  19. Isotopic identification using Pulse Shape Analysis of current signals from silicon detectors: Recent results from the FAZIA collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Pastore, G., E-mail: pastore@fi.infn.it [Dipartimento di Fisica, Università di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); INFN Sezione di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); Gruyer, D. [INFN Sezione di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); Ottanelli, P. [Dipartimento di Fisica, Università di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); INFN Sezione di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); Le Neindre, N. [LPC Caen, Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, LPC Caen, 14000 Caen (France); Pasquali, G. [Dipartimento di Fisica, Università di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); INFN Sezione di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); Alba, R. [INFN LNS, Via S.Sofia 62, 95123 Catania (Italy); Barlini, S.; Bini, M. [Dipartimento di Fisica, Università di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); INFN Sezione di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); Bonnet, E. [SUBATECH, EMN-IN2P3/CNRS-Université de Nantes, Nantes (France); GANIL, CEA/DSM-CNRS/IN2P3, B.P. 5027, F-14076 Caen Cedex (France); Borderie, B. [Institut de Physique Nucléaire, CNRS-IN2P3, Univ. Paris-Sud, Université Paris-Saclay, F-91406 Orsay Cedex (France); Bougault, R. [LPC Caen, Normandie Univ, ENSICAEN, UNICAEN, CNRS/IN2P3, LPC Caen, 14000 Caen (France); Bruno, M. [INFN, Sezione di Bologna, Viale Berti Pichat 6/2, 40127 Bologna (Italy); Casini, G. [INFN Sezione di Firenze, via G.Sansone 1, 50019 Sesto Fiorentino (Italy); Chbihi, A. [GANIL, CEA/DSM-CNRS/IN2P3, B.P. 5027, F-14076 Caen Cedex (France); and others

    2017-07-11

    The FAZIA apparatus exploits Pulse Shape Analysis (PSA) to identify nuclear fragments stopped in the first layer of a Silicon-Silicon-CsI(Tl) detector telescope. In this work, for the first time, we show that the isotopes of fragments having atomic number as high as Z∼20 can be identified. Such a remarkable result has been obtained thanks to a careful construction of the Si detectors and to the use of low noise and high performance digitizing electronics. Moreover, optimized PSA algorithms are needed. This work deals with the choice of the best algorithm for PSA of current signals. A smoothing spline algorithm is demonstrated to give optimal results without requiring too much computational resources.

  20. Characterization of interference thin films grown on stainless steel surface by alternate pulse current in a sulphochromic solution

    Directory of Open Access Journals (Sweden)

    Rosa Maria Rabelo Junqueira

    2008-12-01

    Full Text Available The aim of this work was to characterize thin interference films grown on the surface of AISI 304 stainless steel for decorative purposes. Films were grown in a sulphochromic solution at room temperature by an alternating pulse current method. The morphology and chemical state of the elements in the films were investigated by field emission scanning electron microscopy (FESEM, atomic force microscopy (AFM, glow discharge optical emission spectrometry (GDOES, and infrared Fourier transform spectroscopy (FTIR. Depth-sensing indentation (DSI experiments and wear abrasion tests were employed to assess the mechanical resistance of the films. The coloration process resulted in porous thin films which increased the surface roughness of the substrate. The interference films mainly consisted of hydrated chromium oxide containing iron. Increasing film thickness produced different colors and affected the mechanical properties of the coating-substrate system. Thicker films, such as those producing gold and green colors, were softer but more abrasion resistant.

  1. Simulating the effects of plasma disruption with a 1 MA current pulse in a coaxial test fixture

    International Nuclear Information System (INIS)

    Praeg, W.F.

    1985-01-01

    A test fixture for simulating plasma disruptions, comprising two coaxial cylinders, has been designed for use with Argonne's electromagnetic test facility FELIX. A pulsed power supply drives a half cycle sine wave current of 10 0 A through the test fixture generating fields of -1 . The coaxial structure is 140 cm long, has an outer cylinder with an OD of 78 cm and an inner cylinder with an OD of 8.3 cm. It is surrounded by the FELIX solenoid field of 1 T. This proposed upgrade of the FELIX facility should be useful for testing the effect of plasma disruption on First Wall-Blanket-Shield (FWBS) structures; a future upgrade of the solenoid field to 4 T will allow to simulate reactor conditions even better

  2. High-current negative-ion sources for pulsed spallation neutron sources: LBNL workshop, October 1994

    International Nuclear Information System (INIS)

    Alonso, J.R.

    1995-09-01

    The neutron scattering community has endorsed the need for a high-power (1 to 5 MW) accelerator-driven source of neutrons for materials research. Properly configured, the accelerator could produce very short (sub-microsecond) bursts of cold neutrons, said time structure offering advantages over the continuous flux from a reactor. The recent cancellation of the ANS reactor project has increased the urgency to develop a comprehensive strategy based on the best technological scenarios. Studies to date have built on the experience from ISIS (the 160 kW source in the UK), and call for a high-current (approx. 100 mA peak) H- source-linac combination injecting into one or more accumulator rings in which beam may be further accelerated. The I to 5 GeV proton beam is extracted in a single turn and brought to the target-moderator stations. The high current, high duty-factor, high brightness and high reliability required of the ion source present a very large challenge to the ion source community. The Workshop reported on here, held in Berkeley in October 1994, analyzed in detail the source requirements for proposed accelerator scenarios, the present performance capabilities of different H- source technologies, and identified necessary R ampersand D efforts to bridge the gap

  3. Study on lower hybrid current drive efficiency at high density towards long-pulse regimes in Experimental Advanced Superconducting Tokamak

    International Nuclear Information System (INIS)

    Li, M. H.; Ding, B. J.; Zhang, J. Z.; Gan, K. F.; Wang, H. Q.; Zhang, L.; Wei, W.; Li, Y. C.; Wu, Z. G.; Ma, W. D.; Jia, H.; Chen, M.; Yang, Y.; Feng, J. Q.; Wang, M.; Xu, H. D.; Shan, J. F.; Liu, F. K.; Peysson, Y.

    2014-01-01

    Significant progress on both L- and H-mode long-pulse discharges has been made recently in Experimental Advanced Superconducting Tokamak (EAST) with lower hybrid current drive (LHCD) [J. Li et al., Nature Phys. 9, 817 (2013) And B. N. Wan et al., Nucl. Fusion 53, 104006 (2013).]. In this paper, LHCD experiments at high density in L-mode plasmas have been investigated in order to explore possible methods of improving current drive (CD) efficiency, thus to extend the operational space in long-pulse and high performance plasma regime. It is observed that the normalized bremsstrahlung emission falls much more steeply than 1/n e-av (line-averaged density) above n e-av  = 2.2 × 10 19  m −3 indicating anomalous loss of CD efficiency. A large broadening of the operating line frequency (f = 2.45 GHz), measured by a radio frequency (RF) probe located outside the EAST vacuum vessel, is generally observed during high density cases, which is found to be one of the physical mechanisms resulting in the unfavorable CD efficiency. Collisional absorption of lower hybrid wave in the scrape off layer (SOL) may be another cause, but this assertion needs more experimental evidence and numerical analysis. It is found that plasmas with strong lithiation can improve CD efficiency largely, which should be benefited from the changes of edge parameters. In addition, several possible methods are proposed to recover good efficiency in future experiments for EAST

  4. Current pulse: can a production system reduce medical errors in health care?

    Science.gov (United States)

    Printezis, Antonios; Gopalakrishnan, Mohan

    2007-01-01

    One of the reasons for rising health care costs is medical errors, a majority of which result from faulty systems and processes. Health care in the past has used process-based initiatives such as Total Quality Management, Continuous Quality Improvement, and Six Sigma to reduce errors. These initiatives to redesign health care, reduce errors, and improve overall efficiency and customer satisfaction have had moderate success. Current trend is to apply the successful Toyota Production System (TPS) to health care since its organizing principles have led to tremendous improvement in productivity and quality for Toyota and other businesses that have adapted them. This article presents insights on the effectiveness of TPS principles in health care and the challenges that lie ahead in successfully integrating this approach with other quality initiatives.

  5. Irradiation tests in BR2 of miniature fission chambers in pulse, Campbelling and current mode

    International Nuclear Information System (INIS)

    Vermeeren, L.; Geslot, B.; Breaud, S.; Filliatre, P.; Jammes, C.; Legrand, A.; Barbot, L.

    2011-01-01

    The FNDS system ('Fast Neutron Detection System') for the on-line in-pile detection of the fast neutron flux in the presence of a significant thermal neutron flux and a high gamma dose rate is being developed in the framework of the SCK.CEN-CEA Laboratoire Commun. The system has been patented in 2008. The system consists of a miniature Pu-242 fission chamber as main detector, complemented by a U-235 fission chamber or a rhodium Self-Powered Neutron Detector (SPND) for thermal neutron flux monitoring and a dedicated acquisition system that also takes care of the processing of the signals from both detectors to extract fast neutron flux data. This paper describes a FNDS qualification experiment in the SCK.CEN BR2 reactor, with experimental results on a large set of fission chambers in current and Campbelling mode. (authors)

  6. Study of Chromium Multilayers Properties Obtained by Pulsed Current Density: Residual Stress and Microhardness

    Directory of Open Access Journals (Sweden)

    Julieta TORRES-GONZÁLEZ

    2010-12-01

    Full Text Available Chromium multilayers deposits were obtained from three different bath solutions, they were prepared by switching current density between 10 and 70 Adm-2. Two temperatures were studied, 35°C and 55°C. At 35°C two different microstructures are alternated: columnar obtained at 10 Adm-2 and equiaxial obtained at 70 Adm-2. At 55°C only the columnar type microstructure is present, at 10 and 70 Adm-2, the only difference among the layers is a slight disorientation of grains. The properties of these chromium multilayers were characterized by scanning electron microscopy (SEM and X-ray diffraction (XRD. In general the deposits are microcracked with a high microhardness, high residual stress and a small grain size.

  7. Re-activation of degraded nickel cermet anodes - Nano-particle formation via reverse current pulses

    Science.gov (United States)

    Hauch, A.; Marchese, M.; Lanzini, A.; Graves, C.

    2018-02-01

    The Ni/yttria-stabilized-zirconia (YSZ) cermet is the most commonly applied fuel electrode for solid oxide cells (SOCs). Loss of Ni/YSZ electrode activity is a key life-time limiting factor of the SOC. Developing means to mitigate this loss of performance or re-activate a fuel electrode is therefore important. In this work, we report a series of five tests on state-of-the-art Ni/YSZ-YSZ-CGObarrier-LSC/CGO cells. All cells were deliberately degraded via gas stream impurities in CO2/CO or harsh steam electrolysis operation. The cells were re-activated via a variety of reverse current treatments (RCTs). Via electrochemical impedance spectroscopy, we found that the Ni/YSZ electrode performance could be recovered via RCT, but not via constant fuel cell operation. For optimized RCT, we obtained a lower Ni/YSZ electrode resistance than the initial resistance. E.g. at 700 °C we measured fuel electrode resistance of 180 mΩ cm2, 390 mΩ cm2, and 159 mΩ cm2 before degradation, after degradation and after re-activation via RCT, respectively. Post-test SEM revealed that the RCT led to formation of nano-particles in the fuel electrode. Besides the remarkable improvement, the results also showed that RCTs can weaken Ni/YSZ interfaces and the electrode/electrolyte interface. This indicates that finding an optimum RCT profile is crucial for achieving maximum benefit.

  8. Characteristics of cold atmospheric plasma source based on low-current pulsed discharge with coaxial electrodes

    Science.gov (United States)

    Bureyev, O. A.; Surkov, Yu S.; Spirina, A. V.

    2017-05-01

    This work investigates the characteristics of the gas discharge system used to create an atmospheric pressure plasma flow. The plasma jet design with a cylindrical graphite cathode and an anode rod located on the axis of the system allows to realize regularly reproducible spark breakdowns mode with a frequency ∼ 5 kHz and a duration ∼ 40 μs. The device generates a cold atmospheric plasma flame with 1 cm in diameter in the flow of various plasma forming gases including nitrogen and air at about 100 mA average discharge current. In the described construction the cathode spots of individual spark channels randomly move along the inner surface of the graphite electrode creating the secondary plasma stream time-average distributed throughout the whole exit aperture area after the decay of numerous filamentary discharge channels. The results of the spectral diagnostics of plasma in the discharge gap and in the stream coming out of the source are presented. Despite the low temperature of atoms and molecules in plasma stream the cathode spots operation with temperature of ∼ 4000 °C at a graphite electrode inside a discharge system enables to saturate the plasma by CN-radicals and atomic carbon in the case of using nitrogen as the working gas.

  9. Injection current dependences of electroluminescence transition energy in InGaN/GaN multiple quantum wells light emitting diodes under pulsed current conditions

    International Nuclear Information System (INIS)

    Zhang, Feng; Ikeda, Masao; Liu, Jianping; Zhang, Shuming; Zhou, Kun; Yang, Hui; Liu, Zongshun

    2015-01-01

    Injection current dependences of electroluminescence transition energy in blue InGaN/GaN multiple quantum wells light emitting diodes (LEDs) with different quantum barrier thicknesses under pulsed current conditions have been analyzed taking into account the related effects including deformation caused by lattice strain, quantum confined Stark effects due to polarization field partly screened by carriers, band gap renormalization, Stokes-like shift due to compositional fluctuations which are supposed to be random alloy fluctuations in the sub-nanometer scale, band filling effect (Burstein-Moss shift), and quantum levels in finite triangular wells. The bandgap renormalization and band filling effect occurring at high concentrations oppose one another, however, the renormalization effect dominates in the concentration range studied, since the band filling effect arising from the filling in the tail states in the valence band of quantum wells is much smaller than the case in the bulk materials. In order to correlate the carrier densities with current densities, the nonradiative recombination rates were deduced experimentally by curve-fitting to the external quantum efficiencies. The transition energies in LEDs both with 15 nm quantum barriers and 5 nm quantum barriers, calculated using full strengths of theoretical macroscopic polarization given by Barnardini and Fiorentini [Phys. Status Solidi B 216, 391 (1999)] are in excellent accordance with experimental results. The LED with 5 nm barriers has been shown to exhibit a higher transition energy and a smaller blue shift than those of LED with 15 nm barriers, which is mainly caused by the smaller internal polarization field in the quantum wells

  10. Injection current dependences of electroluminescence transition energy in InGaN/GaN multiple quantum wells light emitting diodes under pulsed current conditions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Feng; Ikeda, Masao, E-mail: mikeda2013@sinano.ac.cn; Liu, Jianping; Zhang, Shuming [Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (CAS), Suzhou 215123 (China); Key Lab of Nanodevices and Applications, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (CAS), Suzhou 215123 (China); Zhou, Kun; Yang, Hui [Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (CAS), Suzhou 215123 (China); Key Lab of Nanodevices and Applications, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (CAS), Suzhou 215123 (China); Institute of Semiconductors (CAS), Beijing 100083 (China); Liu, Zongshun [Institute of Semiconductors (CAS), Beijing 100083 (China)

    2015-07-21

    Injection current dependences of electroluminescence transition energy in blue InGaN/GaN multiple quantum wells light emitting diodes (LEDs) with different quantum barrier thicknesses under pulsed current conditions have been analyzed taking into account the related effects including deformation caused by lattice strain, quantum confined Stark effects due to polarization field partly screened by carriers, band gap renormalization, Stokes-like shift due to compositional fluctuations which are supposed to be random alloy fluctuations in the sub-nanometer scale, band filling effect (Burstein-Moss shift), and quantum levels in finite triangular wells. The bandgap renormalization and band filling effect occurring at high concentrations oppose one another, however, the renormalization effect dominates in the concentration range studied, since the band filling effect arising from the filling in the tail states in the valence band of quantum wells is much smaller than the case in the bulk materials. In order to correlate the carrier densities with current densities, the nonradiative recombination rates were deduced experimentally by curve-fitting to the external quantum efficiencies. The transition energies in LEDs both with 15 nm quantum barriers and 5 nm quantum barriers, calculated using full strengths of theoretical macroscopic polarization given by Barnardini and Fiorentini [Phys. Status Solidi B 216, 391 (1999)] are in excellent accordance with experimental results. The LED with 5 nm barriers has been shown to exhibit a higher transition energy and a smaller blue shift than those of LED with 15 nm barriers, which is mainly caused by the smaller internal polarization field in the quantum wells.

  11. Electrochemical corrosion and bioactivity of Ti-Nb-Sn-hydroxyapatite composites fabricated by pulse current activated sintering.

    Science.gov (United States)

    Xiaopeng, Wang; Fantao, Kong; Biqing, Han; Yuyong, Chen

    2017-11-01

    Ti-Nb-Sn-hydroxyapatite (HA) composites were prepared by mechanical alloying for different times (unmilled, 4, 8 and 12h), followed by pulse current activated sintering. The effects of the milling time on the electrochemical corrosion resistance and bioactivity of the sintered Ti-35Nb-2.5Sn-15HA composites were investigated. Potentiodynamic polarization test results indicated that the sintered Ti-35Nb-2.5Sn-15HA composites exhibited higher corrosion resistance with increasing milling time. The corrosion potential and current of the Ti-35Nb-2.5Sn-15HA composite sintered by 12h milled powders were - 0.261V and 0.18μA/cm 2 , respectively, and this sintered composite showed a stable and wide passivation region. The hemolysis rate of the sintered Ti-35Nb-2.5Sn-15HA composites reduced with increasing milling time and the lowest hemolytic rate of the composites was 0.87%. In addition, the in vitro cell culture results indicated that the composite sintered by 12h milled powders had good biocompatibility. These results indicate the significant potential of Ti-35Nb-2.5Sn/xHA composites for biomedical implant applications. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Electronic regulation of the SPS extraction quadrupole current pulse shape for improved stability of the extracted beam

    CERN Document Server

    Carlier, E; Vossenberg, Eugène B; CERN. Geneva. SPS and LEP Division

    1996-01-01

    In order to minimise the event pile-up and therefore optimise the detection efficiency, Chorus and Nomad experiments ask for a long and rectangular spill profile. At present the fast-slow extractio n is generated by driving the beam into a quadrupolar-octopolar resonance by exciting a quadrupole magnet with a semi-trapezoidal current [1]. The trapezoidal pulse shape is obtained by dischargin g a capacitor into the magnet coils. After a few milliseconds of undamped discharge a fixed resistor is switched into the circuit. The attenuation is then higher and the sine wave continues with a lower gradient. The two gradients can be adjusted by varying the initial capacitor voltage and the time at which the resistor is switched into the circuit. A further degree of freedom in determini ng the spill shape has been added by allowing the possibility of changing the second slope value independently of the initial conditions. This task is achieved by means of a variable current sour ce added in parallel to the fixed resis...

  13. Fabrication of Bi-doped YIG optical thin film for electric current sensor by pulsed laser deposition

    International Nuclear Information System (INIS)

    Hayashi, Hiromitsu; Iwasa, Souhachi; Vasa, Nilesh J.; Yoshitake, Tsuyoshi; Ueda, Kiyotaka; Yokoyama, Shigeru; Higuchi, Sadao; Takeshita, Hirohito; Nakahara, Michitaka

    2002-01-01

    Bi-doped yttrium iron garnet (Bi x Y 3-x Fe 5 O 12 , Bi:YIG) thin films, which can be used as electric current sensors, are grown on Gd 3 Ga 5 O 12 (GGG) substrates by pulsed laser deposition (PLD) using an ArF excimer laser. The growth condition for high quality epitaxial Bi:YIG thin films is investigated by varying the PLD process parameters, such as the substrate temperature and ambient oxygen gas pressure. The epitaxial film growth is attained at the substrate temperature of around 500 deg. C and at ambient oxygen pressure between 125 and 175 mTorr. The optical properties of epitaxial films are measured and the maximum magneto-optic sensitivity coefficient is observed to be 44.1 deg. /T with a film thickness of about 0.7 μm at a wavelength of 500 nm. The results indicate that the PLD technique can be useful for realizing a miniature current sensing device with the Bi:YIG thin film

  14. Measuring the critical current in superconducting samples made of NT-50 under pulse irradiation by high-energy particles

    International Nuclear Information System (INIS)

    Vasilev, P.G.; Vladimirova, N.M.; Volkov, V.I.; Goncharov, I.N.; Zajtsev, L.N.; Zel'dich, B.D.; Ivanov, V.I.; Kleshchenko, E.D.; Khvostov, V.B.

    1981-01-01

    The results of tests of superconducting samples of an uninsulated wire of the 0.5 mm diameter, containing 1045 superconducting filaments of the 10 μm diameter made of NT-50 superconductor in a copper matrix, are given. The upper part of the sample (''closed'') is placed between two glass-cloth-base laminate plates of the 50 mm length, and the lower part (''open'') of the 45 mm length is immerged into liquid helium. The sample is located perpendicular to the magnetic field of a superconducting solenoid and it is irradiated by charged particle beams at the energy of several GeV. The measurement results of permissible energy release in the sample depending on subcriticality (I/Isub(c) where I is an operating current through the sample, and Isub(c) is a critical current for lack of the beam) and the particle flux density, as well as of the maximum permissible fluence depending on subcriticality. In case of the ''closed'' sample irradiated by short pulses (approximately 1 ms) for I/Isub(c) [ru

  15. Examination of pulsed eddy current for inspection of second layer aircraft wing lap-joint structures using outlier detection methods

    Energy Technology Data Exchange (ETDEWEB)

    Butt, D.M., E-mail: Dennis.Butt@forces.gc.ca [Royal Military College of Canada, Dept. of Chemistry and Chemical Engineering, Kingston, Ontario (Canada); Underhill, P.R.; Krause, T.W., E-mail: Thomas.Krause@rmc.ca [Royal Military College of Canada, Dept. of Physics, Kingston, Ontario (Canada)

    2016-09-15

    Ageing aircraft are susceptible to fatigue cracks at bolt hole locations in multi-layer aluminum wing lap-joints due to cyclic loading conditions experienced during typical aircraft operation, Current inspection techniques require removal of fasteners to permit inspection of the second layer from within the bolt hole. Inspection from the top layer without fastener removal is desirable in order to minimize aircraft downtime while reducing the risk of collateral damage. The ability to detect second layer cracks without fastener removal has been demonstrated using a pulsed eddy current (PEC) technique. The technique utilizes a breakdown of the measured signal response into its principal components, each of which is multiplied by a representative factor known as a score. The reduced data set of scores, which represent the measured signal, are examined for outliers using cluster analysis methods in order to detect the presence of defects. However, the cluster analysis methodology is limited by the fact that a number of representative signals, obtained from fasteners where defects are not present, are required in order to perform classification of the data. Alternatively, blind outlier detection can be achieved without having to obtain representative defect-free signals, by using a modified smallest half-volume (MSHV) approach. Results obtained using this approach suggest that self-calibrating blind detection of cyclic fatigue cracks in second layer wing structures in the presence of ferrous fasteners is possible without prior knowledge of the sample under test and without the use of costly calibration standards. (author)

  16. Examination of pulsed eddy current for inspection of second layer aircraft wing lap-joint structures using outlier detection methods

    International Nuclear Information System (INIS)

    Butt, D.M.; Underhill, P.R.; Krause, T.W.

    2016-01-01

    Ageing aircraft are susceptible to fatigue cracks at bolt hole locations in multi-layer aluminum wing lap-joints due to cyclic loading conditions experienced during typical aircraft operation, Current inspection techniques require removal of fasteners to permit inspection of the second layer from within the bolt hole. Inspection from the top layer without fastener removal is desirable in order to minimize aircraft downtime while reducing the risk of collateral damage. The ability to detect second layer cracks without fastener removal has been demonstrated using a pulsed eddy current (PEC) technique. The technique utilizes a breakdown of the measured signal response into its principal components, each of which is multiplied by a representative factor known as a score. The reduced data set of scores, which represent the measured signal, are examined for outliers using cluster analysis methods in order to detect the presence of defects. However, the cluster analysis methodology is limited by the fact that a number of representative signals, obtained from fasteners where defects are not present, are required in order to perform classification of the data. Alternatively, blind outlier detection can be achieved without having to obtain representative defect-free signals, by using a modified smallest half-volume (MSHV) approach. Results obtained using this approach suggest that self-calibrating blind detection of cyclic fatigue cracks in second layer wing structures in the presence of ferrous fasteners is possible without prior knowledge of the sample under test and without the use of costly calibration standards. (author)

  17. Comparison of premodulated interferential and pulsed current electrical stimulation in prevention of deep muscle atrophy in rats.

    Science.gov (United States)

    Tanaka, Minoru; Hirayama, Yusuke; Fujita, Naoto; Fujino, Hidemi

    2013-04-01

    The goal of this study was to compare the effects of electrical stimulation using pulsed current (PC) and premodulated interferential current (IC) on prevention of muscle atrophy in the deep muscle layer of the calf. Rats were randomly divided into 3 treatment groups: control, hindlimb unloading for 2 weeks (HU), and HU plus electrical stimulation for 2 weeks. The animals in the electrical stimulation group received therapeutic stimulation of the left (PC) or right (IC) calf muscles twice a day during the unloading period. Animals undergoing HU for 2 weeks exhibited significant loss of muscle mass, decreased cross-sectional area (CSA) of muscle fibers, and increased expression of ubiquitinated proteins in the gastrocnemius and soleus muscles compared with control animals. Stimulation with PC attenuated the effects on the muscle mass, fiber CSA, and ubiquitinated proteins in the gastrocnemius muscle. However, PC stimulation failed to prevent atrophy of the deep layer of the gastrocnemius muscle and the soleus muscle. In contrast, stimulation with IC inhibited atrophy of both the gastrocnemius and soleus muscles. In addition, the IC protocol inhibited the HU-induced increase in ubiquitinated protein expression in both gastrocnemius and soleus muscles. These results suggest that electrical stimulation with IC is more effective than PC in preventing muscle atrophy in the deep layer of limb muscles.

  18. Effects of Transcranial Direct Current Stimulation, Transcranial Pulsed Current Stimulation, and Their Combination on Brain Oscillations in Patients with Chronic Visceral Pain: A Pilot Crossover Randomized Controlled Study

    Directory of Open Access Journals (Sweden)

    Aurore Thibaut

    2017-11-01

    Full Text Available ObjectiveChronic visceral pain (CVP syndromes are persistently painful disorders with a remarkable lack of effective treatment options. This study aimed at evaluating the effects of different neuromodulation techniques in patients with CVP on cortical activity, through electreocephalography (EEG and on pain perception, through clinical tests.DesignA pilot crossover randomized controlled study.SettingsOut-patient.SubjectsAdults with CVP (>3 months.MethodsParticipants received four interventions in a randomized order: (1 transcranial pulsed current stimulation (tPCS and active transcranial direct current stimulation (tDCS combined, (2 tPCS alone, (3 tDCS alone, and (4 sham condition. Resting state quantitative electroencephalography (qEEG and pain assessments were performed before and after each intervention. Results were compared with a cohort of 47 healthy controls.ResultsWe enrolled six patients with CVP for a total of 21 visits completed. Compared with healthy participants, patients with CVP showed altered cortical activity characterized by increased power in theta, alpha and beta bands, and a significant reduction in the alpha/beta ratio. Regarding tES, the combination of tDCS with tPCS had no effect on power in any of the bandwidths, nor brain regions. Comparing tPCS with tDCS alone, we found that tPCS induced higher increase in power within the theta and alpha bandwidths.ConclusionThis study confirms that patients with CVP present abnormal EEG-indexed cortical activity compared with healthy controls. Moreover, we showed that combining two types of neurostimulation techniques had no effect, whereas the two interventions, when applied individually, have different neural signatures.

  19. A New Type of Biphasic Calcium Phosphate Cement as a Gentamicin Carrier for Osteomyelitis

    Directory of Open Access Journals (Sweden)

    Wen-Yu Su

    2013-01-01

    Full Text Available Osteomyelitis therapy is a long-term and inconvenient procedure for a patient. Antibiotic-loaded bone cements are both a complementary and alternative treatment option to intravenous antibiotic therapy for the treatment of osteomyelitis. In the current study, the biphasic calcium phosphate cement (CPC, called α-TCP/HAP (α-tricalcium phosphate/hydroxyapatite biphasic cement, was prepared as an antibiotics carrier for osteomyelitis. The developed biphasic cement with a microstructure of α-TCP surrounding the HAP has a fast setting time which will fulfill the clinical demand. The X-ray diffraction and Fourier transform infrared spectrometry analyses showed the final phase to be HAP, the basic bone mineral, after setting for a period of time. Scanning electron microscopy revealed a porous structure with particle sizes of a few micrometers. The addition of gentamicin in α-TCP/HAP would delay the transition of α-TCP but would not change the final-phase HAP. The gentamicin-loaded α-TCP/HAP supplies high doses of the antibiotic during the initial 24 hours when they are soaked in phosphate buffer solution (PBS. Thereafter, a slower drug release is produced, supplying minimum inhibitory concentration until the end of the experiment (30 days. Studies of growth inhibition of Staphylococcus aureus and Pseudomonas aeruginosa in culture indicated that gentamicin released after 30 days from α-TCP/HAP biphasic cement retained antibacterial activity.

  20. A high current pulsed power generator CQ-3-MMAF with co-axial cable transmitting energy for material dynamics experiments

    Science.gov (United States)

    Wang, Guiji; Chen, Xuemiao; Cai, Jintao; Zhang, Xuping; Chong, Tao; Luo, Binqiang; Zhao, Jianheng; Sun, Chengwei; Tan, Fuli; Liu, Cangli; Wu, Gang

    2016-06-01

    A high current pulsed power generator CQ-3-MMAF (Multi-Modules Assembly Facility, MMAF) was developed for material dynamics experiments under ramp wave and shock loadings at the Institute of Fluid Physics (IFP), which can deliver 3 MA peak current to a strip-line load. The rise time of the current is 470 ns (10%-90%). Different from the previous CQ-4 at IFP, the CQ-3-MMAF energy is transmitted by hundreds of co-axial high voltage cables with a low impedance of 18.6 mΩ and low loss, and then hundreds of cables are reduced and converted to tens of cables into a vacuum chamber by a cable connector, and connected with a pair of parallel metallic plates insulated by Kapton films. It is composed of 32 capacitor and switch modules in parallel. The electrical parameters in short circuit are with a capacitance of 19.2 μF, an inductance of 11.7 nH, a resistance of 4.3 mΩ, and working charging voltage of 60 kV-90 kV. It can be run safely and stable when charged from 60 kV to 90 kV. The vacuum of loading chamber can be up to 10-2 Pa, and the current waveforms can be shaped by discharging in time sequences of four groups of capacitor and switch modules. CQ-3-MMAF is an adaptive machine with lower maintenance because of its modularization design. The COMSOL Multi-physics® code is used to optimize the structure of some key components and calculate their structural inductance for designs, such as gas switches and cable connectors. Some ramp wave loading experiments were conducted to check and examine the performances of CQ-3-MMAF. Two copper flyer plates were accelerated to about 3.5 km/s in one shot when the working voltage was charged to 70 kV. The velocity histories agree very well. The dynamic experiments of some polymer bonded explosives and phase transition of tin under ramp wave loadings were also conducted. The experimental data show that CQ-3-MMAF can be used to do material dynamics experiments in high rate and low cost shots. Based on this design concept, the peak

  1. A high current pulsed power generator CQ-3-MMAF with co-axial cable transmitting energy for material dynamics experiments.

    Science.gov (United States)

    Wang, Guiji; Chen, Xuemiao; Cai, Jintao; Zhang, Xuping; Chong, Tao; Luo, Binqiang; Zhao, Jianheng; Sun, Chengwei; Tan, Fuli; Liu, Cangli; Wu, Gang

    2016-06-01

    A high current pulsed power generator CQ-3-MMAF (Multi-Modules Assembly Facility, MMAF) was developed for material dynamics experiments under ramp wave and shock loadings at the Institute of Fluid Physics (IFP), which can deliver 3 MA peak current to a strip-line load. The rise time of the current is 470 ns (10%-90%). Different from the previous CQ-4 at IFP, the CQ-3-MMAF energy is transmitted by hundreds of co-axial high voltage cables with a low impedance of 18.6 mΩ and low loss, and then hundreds of cables are reduced and converted to tens of cables into a vacuum chamber by a cable connector, and connected with a pair of parallel metallic plates insulated by Kapton films. It is composed of 32 capacitor and switch modules in parallel. The electrical parameters in short circuit are with a capacitance of 19.2 μF, an inductance of 11.7 nH, a resistance of 4.3 mΩ, and working charging voltage of 60 kV-90 kV. It can be run safely and stable when charged from 60 kV to 90 kV. The vacuum of loading chamber can be up to 10(-2) Pa, and the current waveforms can be shaped by discharging in time sequences of four groups of capacitor and switch modules. CQ-3-MMAF is an adaptive machine with lower maintenance because of its modularization design. The COMSOL Multi-physics® code is used to optimize the structure of some key components and calculate their structural inductance for designs, such as gas switches and cable connectors. Some ramp wave loading experiments were conducted to check and examine the performances of CQ-3-MMAF. Two copper flyer plates were accelerated to about 3.5 km/s in one shot when the working voltage was charged to 70 kV. The velocity histories agree very well. The dynamic experiments of some polymer bonded explosives and phase transition of tin under ramp wave loadings were also conducted. The experimental data show that CQ-3-MMAF can be used to do material dynamics experiments in high rate and low cost shots. Based on this design concept, the peak

  2. Biphasic activity of a jumping spider

    Science.gov (United States)

    Okuyama, Toshinori

    2011-01-01

    Individual variation is a ubiquitous and important factor that affects ecological dynamics. This study examined individual variation in the nest-use pattern of the jumping spider Phidippus audax. Although the jumping spider is a diurnal species, field observations in this study revealed that the majority of individuals remained in their nests during the day. An accompanying examination of the hunger level of the spiders revealed that spiders that remained in nests were more starved than those observed outside nests. If spiders actively forage when they are starved, as has been suggested by previous studies, one would expect to see the opposite trend (i.e., spiders that remained in nests are more satiated). Thus, the pattern observed in the field contradicts the known behavioral pattern of the spiders. An individual-based model was used to investigate the behavioral mechanism of the spider and the discrepancy found in the observations. A basic assumption of the model is that spiders possess distinct inactive and active phases (biphasic activity pattern), and transitions between the two phases are regulated by the hunger level of the spider. Data from a laboratory experiment were used to examine the assumptions of the model partially. The model was able to capture patterns observed in the data, suggesting that the pattern of transitions in biphasic activity is an important trait of the foraging behavior of the jumping spider.

  3. Microstructure and mechanical properties of boron-fiber-reinforced titanium-matrix composites produced by pulsed current hot pressing (PCHP)

    International Nuclear Information System (INIS)

    Mizuuchi, Kiyoshi; Inoue, Kanryu; Sugioka, Masami; Itami, Masao; Kawahara, Masakazu; Yamauchi, Isamu

    2006-01-01

    Boron-fiber-reinforced Ti-matrix composites were fabricated by a pulsed current hot pressing (PCHP) process at various holding temperatures between 973 and 1273 K at a pressure of 32 MPa for 600 s. It was found that the boron fiber and the Ti-matrix were well bonded when the PCHP process was carried out at 1073 K. When a holding temperature of the PCHP process was higher than 1173 K, a TiB 2 compound layer was formed along the interface between the boron fiber and the matrix, and crystallization of amorphous boron occurred in the vicinity of the tungsten core in the fiber. The thickness of TiB 2 layer and the amount of crystallized boron increased with increasing holding temperature. The composite produced by the PCHP process at 1073 K with 17.2 vol.% boron fiber presented a tensile yield stress of 706 MPa when deformed at room temperature. This value was about 80% of the yield stress estimated by a force-equilibrium equation of a composite taking into account the direction of fiber axis

  4. A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

    International Nuclear Information System (INIS)

    Krause, T. W.; Babbar, V. K.; Underhill, P. R.

    2014-01-01

    Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators

  5. Development of soft ionization using direct current pulse glow discharge plasma source in mass spectrometry for volatile organic compounds analysis

    Science.gov (United States)

    Nunome, Yoko; Kodama, Kenji; Ueki, Yasuaki; Yoshiie, Ryo; Naruse, Ichiro; Wagatsuma, Kazuaki

    2018-01-01

    This study describes an ionization source for mass analysis, consisting of glow discharge plasma driven by a pulsed direct-current voltage for soft plasma ionization, to detect toxic volatile organic compounds (VOCs) rapidly and easily. The novelty of this work is that a molecular adduct ion, in which the parent molecule attaches with an NO+ radical, [M + NO]+, can be dominantly detected as a base peak with little or no fragmentation of them in an ambient air plasma at a pressure of several kPa. Use of ambient air as the discharge plasma gas is suitable for practical applications. The higher pressure in an ambient air discharge provided a stable glow discharge plasma, contributing to the soft ionization of organic molecules. Typical mass spectra of VOCs toluene, benzene, o-xylene, chlorobenzene and n-hexane were observed as [M + NO]+ adduct ion whose peaks were detected at m/z 122, 108, 136, 142 and 116, respectively. The NO generation was also confirmed by emission bands of NO γ-system. The ionization reactions were suggested, such that NO+ radical formed in an ambient air discharge could attach with the analyte molecule.

  6. A Framework for the Modelling of Biphasic Reacting Systems

    DEFF Research Database (Denmark)

    Anantpinijwatna, Amata; Sin, Gürkan; O’Connell, John P.

    2014-01-01

    Biphasic reacting systems have a broad application range from organic reactions in pharmaceutical and agro-bio industries to CO 2 capture. However, mathematical modelling of biphasic reacting systems is a formidable challenge due to many phenomena underlying the process such as chemical equilibrium...

  7. A simulation study of the reaction of human heart to biphasic electrical shocks

    Directory of Open Access Journals (Sweden)

    Seemann Gunnar

    2004-06-01

    Full Text Available Abstract Background This article presents a study, which examines the effects of biphasic electrical shocks on human ventricular tissue. The effects of this type of shock are not yet fully understood. Animal experiments showed the superiority of biphasic shocks over monophasic ones in defibrillation. A mathematical computer simulation can increase the knowledge of human heart behavior. Methods The research presented in this article was done with different models representing a three-dimensional wedge of ventricular myocardium. The electrophysiology was described with Priebe-Beuckelmann model. The realistic fiber twist, which is specific to human myocardium was included. Planar electrodes were placed at the ends of the longest side of the virtual cardiac wedge, in a bath medium. They were sources of electrical shocks, which varied in magnitude from 0.1 to 5 V. In a second arrangement ring electrodes were placed directly on myocardium for getting a better view on secondary electrical sources. The electrical reaction of the tissue was generated with a bidomain model. Results The reaction of the tissue to the electrical shock was specific to the initial imposed characteristics. Depolarization appeared in the first 5 ms in different locations. A further study of the cardiac tissue behavior revealed, which features influence the response of the considered muscle. It was shown that the time needed by the tissue to be totally depolarized is much shorter when a biphasic shock is applied. Each simulation ended only after complete repolarization was achieved. This created the possibility of gathering information from all states corresponding to one cycle of the cardiac rhythm. Conclusions The differences between the reaction of the homogeneous tissue and a tissue, which contains cleavage planes, reveals important aspects of superiority of biphasic pulses. ...

  8. INTERACTION OF RADIATION WITH MATTER. LASER PLASMA: Increase in the amplitude of hf currents during exposure of a neutral target to microsecond CO2 laser pulses

    Science.gov (United States)

    Antipov, A. A.; Losev, Leonid L.; Meshalkin, E. A.

    1988-09-01

    High-frequency electric currents were generated by irradiation of a metal target with CO2 laser pulses. It was found that the region where the ambient gas was photoionized had a decisive influence on the hf current amplitude. A method for increasing the amplitude of the current by creating an auxiliary laser jet on the target was proposed and used. An hf current of up to 1 A amplitude was observed at a frequency of 75 MHz and this current lasted for 1.5 μs.

  9. AQUEOUS BIPHASE EXTRACTION FOR PROCESSING OF FINE COAL

    Energy Technology Data Exchange (ETDEWEB)

    K. Osseo-Asare; X. Zeng

    2002-01-01

    The objective of this research project is to develop an aqueous biphase extraction process for the treatment of fine coals. Aqueous biphase extraction is an advanced separation technology that relies on the ability of an aqueous system consisting of a water-soluble polymer and another component, e.g., another polymer, an inorganic salt, or a nonionic surfactant, to separate into two immiscible aqueous phases. The principle behind the partition of solid particles in aqueous biphase systems is the physicochemical interaction between the solid surface and the surrounding liquid solution. In order to remove sulfur and mineral matter from fine coal with aqueous biphasic extraction, it is necessary to know the partitioning behavior of coal, as well as the inorganic mineral components. Therefore, in this research emphasis was placed on the partitioning behavior of fine coal particles as well as model fine inorganic particles in aqueous biphase systems.

  10. AQUEOUS BIPHASE EXTRACTION FOR PROCESSING OF FINE COAL; FINAL

    International Nuclear Information System (INIS)

    K. Osseo-Asare; X. Zeng

    2002-01-01

    The objective of this research project is to develop an aqueous biphase extraction process for the treatment of fine coals. Aqueous biphase extraction is an advanced separation technology that relies on the ability of an aqueous system consisting of a water-soluble polymer and another component, e.g., another polymer, an inorganic salt, or a nonionic surfactant, to separate into two immiscible aqueous phases. The principle behind the partition of solid particles in aqueous biphase systems is the physicochemical interaction between the solid surface and the surrounding liquid solution. In order to remove sulfur and mineral matter from fine coal with aqueous biphasic extraction, it is necessary to know the partitioning behavior of coal, as well as the inorganic mineral components. Therefore, in this research emphasis was placed on the partitioning behavior of fine coal particles as well as model fine inorganic particles in aqueous biphase systems

  11. Using irregularly spaced current peaks to generate an isolated attosecond X-ray pulse in free-electron lasers.

    Science.gov (United States)

    Tanaka, Takashi; Parc, Yong Woon; Kida, Yuichiro; Kinjo, Ryota; Shim, Chi Hyun; Ko, In Soo; Kim, Byunghoon; Kim, Dong Eon; Prat, Eduard

    2016-11-01

    A method is proposed to generate an isolated attosecond X-ray pulse in free-electron lasers, using irregularly spaced current peaks induced in an electron beam through interaction with an intense short-pulse optical laser. In comparison with a similar scheme proposed in a previous paper, the irregular arrangement of current peaks significantly improves the contrast between the main and satellite pulses, enhances the attainable peak power and simplifies the accelerator layout. Three different methods are proposed for this purpose and achievable performances are computed under realistic conditions. Numerical simulations carried out with the best configuration show that an isolated 7.7 keV X-ray pulse with a peak power of 1.7 TW and pulse length of 70 as can be generated. In this particular example, the contrast is improved by two orders of magnitude and the peak power is enhanced by a factor of three, when compared with the previous scheme.

  12. Structural, Optical, and Dielectric Investigations of the Relaxor PLZT 9,75/65/35 Ceramics Irradiated by High-Current Pulsed Electron Beam

    CERN Document Server

    Efimov, V V; Kalmikov, A V; Klevtsova, E A; Minashkin, V F; Novikova, N N; Sikolenko, V V; Skripnik, A V; Sternberg, A; Tiutiunnikov, S I; Yakovlev, V A

    2002-01-01

    First time comprehensive study of high-current pulsed electron irradiation effects on the structural, optical and dielectric properties of relaxor (Pb_{(1-x)}La^{x}(Zr_{0.65}Ti_{0.35})_{1-x/4}O_{3} ceramics with x=9.75% has been provided. The electron beam had the following parameters: energy E_{e}=250 keV, current density J_{e}=1000 A/cm^{2}, pulse duration tau = 300 ns, density 10^{15} electrons/cm^{2} per pulse. Infrared reflectivity spectra in the region of 100-2000 cm^{-1} were obtained in virgin, irradiated by 1500 pulses and annealed up to t=500^{circ}C ceramics. The reconstruction of perovskite ABO_{3} structure in irradiated samples has been studied by complex use of X-ray and neutron scattering and IR spectroscopy techniques revealing the changes in transverse and longitudinal phonon modes, oscillators strength and damping of modes. Radiation effects on temperature behaviour of dielectric permittivity in the region of phase transition were studied. The possible mechanisms of pulsed electron irradiat...

  13. Elimination of DC-Link Current Ripple for Modular Multilevel Converters With Capacitor Voltage-Balancing Pulse-Shifted Carrier PWM

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2015-01-01

    The modular multilevel converter (MMC) is attractive for medium- and high-power applications because of its high modularity, availability, and power quality. In this paper, the current ripple on the dc link of the three-phase MMC derived from the phase-shifted carrier-based pulse-width modulation...

  14. Fiber transmission and generation of ultrawideband pulses by direct current modulation of semi-conductor lasers and chirp-to-intensity conversion

    DEFF Research Database (Denmark)

    Company Torres, Victor; Prince, Kamau; Tafur Monroy, Idelfonso

    2008-01-01

    Optical pulses generated by current modulation of semiconductor lasers are strongly frequency chirped. This effect has been considered pernicious for optical communications. We take advantage of this effect for the generation of ultrawideband microwave signals by using an optical filter to achieve...

  15. A current-pulsed power supply with rapid rising and falling edges for magnetic perturbation coils on the J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Yan, M.X. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Rao, B., E-mail: borao@hust.edu.cn [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China); Ding, Y.H.; Hu, Q.M.; Hu, F.R.; Li, D.; Li, M.; Ji, X.K.; Xu, G.; Zheng, W.; Jiang, Z.H. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China); College of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2017-02-15

    Highlights: • The power supply is required to have rapid rising and falling edges. • A modified topology based on the buck chopper of current-pulsed power supply is presented and analyzed. • An entity meeting the electrical requirements has been constructed. • The spike voltage of IGBT is qualitatively analyzed. - Abstract: This study presents the design and principle of a current-pulsed power supply (CPPS) for the tearing mode (TM) feedback control of the J-TEXT tokamak. CPPS is a new method of stabilizing large magnetic islands and accelerating mode rotation through the use of modulated magnetic perturbation. In this application, continuous magnetic perturbation pulse trains with frequency of 1 kHz to kHz, amplitude of 0.25 G, and duty ratio of 20%–50% are required generating via in-vessel magnetic coils. A modified topology based on buck chopper is raised to satisfy the demands of inductive load. This modified topology is characterized by high frequency, rapid rising and falling edges, and large amplitude of current pulses. Appropriate RCD snubber circuit is applied to protect the Insulated Gate Bipolar Transistor (IGBT) switch device. Equipment with peak current that reaches 1 kA, frequency that ranges from 1 kHz to 3 kHz, and rising and falling time within 100 μs was constructed and applied to physical experiment.

  16. Plasma Formation and Evolution on Cu, Al, Ti, and Ni Surfaces Driven by a Mega-Ampere Current Pulse

    Science.gov (United States)

    Yates, Kevin C.

    Metal alloy mm-diameter rods have been driven by a 1-MA, 100-ns current pulse from the Zebra z-pinch. The intense current produces megagauss surface magnetic fields that diffuse into the load, ohmically heating the metal until plasma forms. Because the radius is much thicker than the skin depth, the magnetic field reaches a much higher value than around a thin-wire load. With the "barbell" load design, plasma formation in the region of interest due to contact arcing or electron avalanche is avoided, allowing for the study of ohmically heated loads. Work presented here will show first evidence of a magnetic field threshold for plasma formation in copper 101, copper 145, titanium, and nickel, and compare with previous work done with aluminum. Copper alloys 101 and 145, titanium grade II, and nickel alloy 200 form plasma when the surface magnetic field reaches 3.5, 3.0, 2.2, and 2.6 megagauss, respectively. Varying the element metal, as well as the alloy, changes multiple physical properties of the load and affects the evolution of the surface material through the multiple phase changes. Similarities and differences between these metals will be presented, giving motivation for continued work with different material loads. During the current rise, the metal is heated to temperatures that cause multiple phase changes. When the surface magnetic field reaches a threshold, the metal ionizes and the plasma becomes pinched against the underlying cooler, dense material. Diagnostics fielded have included visible light radiometry, two-frame shadowgraphy (266 and 532 nm wavelengths), time-gated EUV spectroscopy, single-frame/2ns gated imaging, and multi-frame/4ns gated imaging with an intensified CCD camera (ICCD). Surface temperature, expansion speeds, instability growth, time of plasma formation, and plasma uniformity are determined from the data. The time-period of potential plasma formation is scrutinized to understand if and when plasma forms on the surface of a heated

  17. Obtaining of ceramics biphasic dense and porous

    International Nuclear Information System (INIS)

    Pallone, E.M.J.A.; Rigo, E.C.S.; Fraga, A.F.

    2010-01-01

    Among the bioceramic hydroxyapatite (HAP) and beta-tricalcium phosphate (beta-TCP) are materials commonly used in biomedical field. Their combined properties result in a material with absorbable and at the same time with bioactive surface. Called biphasic ceramics such materials respond more quickly when exposed to physiological environment. In this work, powders of HAP/beta-TCP were obtained by chemical precipitation. After obtaining the post-phase was added at a ratio of 0, 15% and 30w% aqueous solutions of corn starch in order to obtain porous bodies. After mixing the resulting solutions were dried, resigned in tablet form and sintered at 1300 deg C. The initial powder was characterized by X-ray diffraction with Rietveld refinement to quantify the phases present. Bodies-of-evidence has been characterized by calculating the bulk density, X-ray diffraction (XRD), scanning electron microscopy and diametral compression. (author)

  18. Invariance of the magnetic behavior and AMI in ferromagnetic biphase films with distinct non-magnetic metallic spacers

    Energy Technology Data Exchange (ETDEWEB)

    Silva, E.F. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Gamino, M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Andrade, A.M.H. de [Instituto de Física, Universidade Federal do Rio Grande de Sul, 91501-970 Porto Alegre, RS (Brazil); Vázquez, M. [Instituto de Ciencia de Materiales de Madrid, CSIC, 28049 Madrid (Spain); Correa, M.A. [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil); Bohn, F., E-mail: felipebohn@fisica.ufrn.br [Departamento de Física, Universidade Federal do Rio Grande do Norte, 59078-900 Natal, RN (Brazil)

    2017-02-01

    We investigate the quasi-static magnetic, magnetotransport, and dynamic magnetic properties in ferromagnetic biphase films with distinct non-magnetic metallic spacer layers. We observe that the nature of the non-magnetic metallic spacer material does not have significant influence on the overall biphase magnetic behavior, and, consequently, on the magnetotransport and dynamic magnetic responses. We focus on the magnetoimpedance effect and verify that the films present asymmetric magnetoimpedance effect. Moreover, we explore the possibility of tuning the linear region of the magnetoimpedance curves around zero magnetic field by varying the probe current frequency in order to achieve higher sensitivity values. The invariance of the magnetic behavior and the asymmetric magnetoimpedance effect in ferromagnetic biphase films with distinct non-magnetic metallic spacers place them as promising candidates for probe element and open possibilities to the development of lower-cost high sensitivity linear magnetic field sensor devices.

  19. Industrial Implementation of Environmentally Friendly Nanometal Electroplating Process for Chromium and Copper Beryllium Replacement using Low Cost Pulse Current Power Supplies

    Science.gov (United States)

    2014-09-10

    Pollutants (NESHAP) and any solid or liquid waste generated from EHC (such as plating sludge ) must be disposed of as hazardous waste in accordance with...or sludge , and baths can be maintained over a number of years without disposal . Table 2-1 Comparison of nCoP and EHC Processes WP-0934 Final...Replacement using Low Cost Pulse Current Power Supplies ESTCP Project WP-200934 SEPTEMBER 2014 Neil Mahalanobis Dennis Malecek Integran

  20. Study of pulsed-current loading of direct methanol fuel cells using a new time-domain model based on bi-functional methanol oxidation kinetics

    Science.gov (United States)

    Vilar, Eric; Dougal, R. A.

    This work describes a non-linear time-domain model of a direct methanol fuel cell (DMFC) and uses that model to show that pulsed-current loading of a direct methanol fuel cell does not improve average efficiency. Unlike previous system level models, the one presented here is capable of predicting the step response of the fuel cell over its entire voltage range. This improved model is based on bi-functional methanol oxidation reaction kinetics and is derived from a lumped, four-step reaction mechanism. In total, six states are incorporated into the model: three states for intermediate surface adsorbates on the anode electrode, two states for the anode and cathode potentials, and one state for the liquid methanol concentration in the anode compartment. Model parameters were identified using experimental data from a real DMFC. The model was applied to study the steady-state and transient performance of a DMFC with the objective to understand the possibility of improving the efficiency of the DMFC by using periodic current pulses to drive adsorbed CO from the anode catalyst. Our results indicate that the pulsed-current method does indeed boost the average potential of the DMFC by 40 mV; but on the other hand, executing that strategy reduces the overall operating efficiency and does not yield any net benefit.

  1. Biphasic Scaffolds from Marine Collagens for Regeneration of Osteochondral Defects

    Directory of Open Access Journals (Sweden)

    Anne Bernhardt

    2018-03-01

    Full Text Available Background: Collagens of marine origin are applied increasingly as alternatives to mammalian collagens in tissue engineering. The aim of the present study was to develop a biphasic scaffold from exclusively marine collagens supporting both osteogenic and chondrogenic differentiation and to find a suitable setup for in vitro chondrogenic and osteogenic differentiation of human mesenchymal stroma cells (hMSC. Methods: Biphasic scaffolds from biomimetically mineralized salmon collagen and fibrillized jellyfish collagen were fabricated by joint freeze-drying and crosslinking. Different experiments were performed to analyze the influence of cell density and TGF-β on osteogenic differentiation of the cells in the scaffolds. Gene expression analysis and analysis of cartilage extracellular matrix components were performed and activity of alkaline phosphatase was determined. Furthermore, histological sections of differentiated cells in the biphasic scaffolds were analyzed. Results: Stable biphasic scaffolds from two different marine collagens were prepared. An in vitro setup for osteochondral differentiation was developed involving (1 different seeding densities in the phases; (2 additional application of alginate hydrogel in the chondral part; (3 pre-differentiation and sequential seeding of the scaffolds and (4 osteochondral medium. Spatially separated osteogenic and chondrogenic differentiation of hMSC was achieved in this setup, while osteochondral medium in combination with the biphasic scaffolds alone was not sufficient to reach this ambition. Conclusions: Biphasic, but monolithic scaffolds from exclusively marine collagens are suitable for the development of osteochondral constructs.

  2. Controlling Charge and Current Neutralization of an Ion Beam Pulse in a Background Plasma by Application of a Solenoidal Magnetic Field I: Weak Magnetic Field Limit

    Energy Technology Data Exchange (ETDEWEB)

    Kaganovich, I. D., Startsev, E. A., Sefkow, A. B., Davidson, R. C.

    2008-10-10

    Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ωce > ωpeβb, where ωce = eβ/mec is the electron gyrofrequency, ωpe is the electron plasma frequency, and βb = Vb/c is the ion beam velocity relative to the speed of light. This condition typically holds for relatively small magnetic fields (about 100G). Analytical formulas are derived for the effective radial force acting on the beam ions, which can be used to minimize beam pinching. The results of analytic theory have been verified by comparison with the simulation results obtained from two particle-in-cell codes, which show good agreement.

  3. Study on the nanostructure formation mechanism of hypereutectic Al–17.5Si alloy induced by high current pulsed electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Bo, E-mail: gaob@smm.neu.edu.cn [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Hu, Liang [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Li, Shi-wei [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Faculty of Metallurgical and Energy Engineering, Kunming University of Science and Technology, Kunming 650093 (China); Hao, Yi [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Zhang, Yu-dong [Laboratoire d’Etude des Textures et Applications aux Matériaux (LETAM, UMR-CNRS 7078), Université Paul Verlaine de Metz, Ile du Saulcy, Metz 57012 (France); Tu, Gan-feng [School of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Grosdidier, Thierry [Laboratoire d’Etude des Textures et Applications aux Matériaux (LETAM, UMR-CNRS 7078), Université Paul Verlaine de Metz, Ile du Saulcy, Metz 57012 (France)

    2015-08-15

    This work investigates the nanostructure forming mechanism of hypereutectic Al–17.5Si alloy associated with the high current pulsed electron beam (HCPEB) treatment with increasing number of pulses by electron backscatter diffraction (EBSD) and SEM. The surface layers were melted and resolidified rapidly. The treated surfaces show different structural characteristics in different compositions and distribution zones. The top melted-layer zone can be divided into three zones: Si-rich, Ai-rich, and intermediate zone. The Al-rich zone has a nano-cellular microstructure with a diameter of ∼100 nm. The microstructure in the Si-rich zone consists of fine, dispersive, and spherical nano-sized Si crystals surrounded by α(Al) cells. Some superfine eutectic structures form in the boundary of the two zones. With the increase of number of pulses, the proportion of Si-rich zone to the whole top surface increases, and more cellular substructures are transformed to fine equiaxed grain. In other words, with increasing number of pulses, more Si elements diffuse to the Al-rich zone and provide heterogeneous nucleation sites, and Al grains are refined dramatically. Moreover, the relationship between the substrate Si phase and crystalline phase is determined by EBSD; that is, (1 1 1){sub Al}//(0 0 1){sub Si} with a value of disregistry δ at approximately 5%. The HCPEB technique is a versatile technique for refining the surface microstructure of hypereutectic Al–Si alloys.

  4. Controlling Charge and Current Neutralization of an Ion Beam Pulse in a Background Plasma by Application of a Solenoidal Magnetic Field I: Weak Magnetic Field Limit

    International Nuclear Information System (INIS)

    Kaganovich, I. D.; Startsev, E. A.; Sefkow, A. B.; Davidson, R. C.

    2008-01-01

    Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite-length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to influence the self-electric and self-magnetic fields when ω ce ∼> ω pe β b , where ω ce = eB/m e c is the electron gyrofrequency, ω pe is the electron plasma frequency, and β b = V b /c is the ion beam velocity relative to the speed of light. This condition typically holds for relatively small magnetic fields (about 100G). Analytical formulas are derived for the effective radial force acting on the beam ions, which can be used to minimize beam pinching. The results of analytic theory have been verified by comparison with the simulation results obtained from two particle-in-cell codes, which show good agreement

  5. EFFECTS OF LASER RADIATION ON MATTER. LASER PLASMA: Generation of currents and propagation of plasma fronts in the case of two-pulse interaction with a target in air

    Science.gov (United States)

    Barkhudarov, É. M.; Gelashvili, G. V.; Gumberidze, G. G.; Taktakishvili, M. I.

    1990-06-01

    An investigation was made of the enhancement in the efficiency of generation of currents when a target in air was subjected to two consecutive CO2 laser radiation pulses. Preliminary interaction with a low-energy (1.5-5 J) pulse increased by more than one order of magnitude the currents generated by the second pulse and this was true in a wide range of energies of the latter pulse. The energy conversion efficiency was practically unaffected. The results were in qualitative agreement with the proposed pattern of plasma formation and propagation of shock waves near a target.

  6. Simultaneously Excitatory and Inhibitory Effects of Transcranial Alternating Current Stimulation Revealed Using Selective Pulse-Train Stimulation in the Rat Motor Cortex.

    Science.gov (United States)

    Khatoun, Ahmad; Asamoah, Boateng; Mc Laughlin, Myles

    2017-09-27

    Transcranial alternating current stimulation (tACS) uses sinusoidal, subthreshold, electric fields to modulate cortical processing. Cortical processing depends on a fine balance between excitation and inhibition and tACS acts on both excitatory and inhibitory cortical neurons. Given this, it is not clear whether tACS should increase or decrease cortical excitability. We investigated this using transcranial current stimulation of the rat (all males) motor cortex consisting of a continuous subthreshold sine wave with short bursts of suprathreshold pulse-trains inserted at different phases to probe cortical excitability. We found that when a low-rate, long-duration, suprathreshold pulse-train was used, subthreshold cathodal tACS decreased cortical excitability and anodal tACS increased excitability. However, when a high-rate, short-duration, suprathreshold pulse-train was used this pattern was inverted. An integrate-and-fire model incorporating biophysical differences between cortical excitatory and inhibitory neurons could predict the experimental data and helped interpret these results. The model indicated that low-rate suprathreshold pulse-trains preferentially stimulate excitatory cortical neurons, whereas high-rate suprathreshold pulse-trains stimulate both excitatory and inhibitory neurons. If correct, this indicates that suprathreshold pulse-train stimulation may be able to selectively control the excitation-inhibition balance within a cortical network. The excitation-inhibition balance then likely plays an important role in determining whether subthreshold tACS will increase or decrease cortical excitability. SIGNIFICANCE STATEMENT Transcranial alternating current stimulation (tACS) is a noninvasive neuromodulation method that uses weak sinusoidal electric fields to modulate cortical activity. In healthy volunteers tACS can modulate perception, cognition, and motor function but the underlying neural mechanism is poorly understood. In this study, using rat

  7. Experiments investigating the effects of the accelerating gap voltage pulse on the ion focused (IFR) high current electron recirculators

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Smith, D.L.; Poukey, J.W.; Wagner, J.S.; Bennett, L.F.; Olson, W.R.; Turman, B.N.; Prestwich, K.R.; Wells, J.

    1991-01-01

    The lifetime of the Ion Focusing Regime (IFR) channel following the pulsing of the post-accelerating gaps is critical for an open-ended, spiral recirculating electron linear accelerator. It dictates the number of allowable beam recirculations through the gap. In the case of a racetrack configuration, it is significant but not as critical, since the presence of the electron beam focuses the ions and lengthens the lifetime of the ion channel. It was established that pulsing the accelerating gap perturbs the IFR channel. However, for the parameters studied, the lifetime is long enough to allow at least four beam recirculations in a spiral device. In addition, cusp fields positioned upstream and downstream from the gap prevent it from perturbing the IFR channel. 4 refs., 5 figs., 1 tab

  8. Experiments investigating the effects of the accelerating gap voltage pulse on the ion focused (IFR) high current electron recirculators

    International Nuclear Information System (INIS)

    Mazarakis, M.G.; Smith, D.L.; Poukey, J.W.; Wagner, J.S.; Bennett, L.F.; Olson, W.R. Turnman, B.N.; Prestwich, K.R.; Wells, J.

    1991-01-01

    The lifetime of the Ion Focusing Regime (IFR) channel following the pulsing of the post-accelerating gaps is critical for an open-ended, spiral recirculating electron linear accelerator. It dictates the number of allowable beam recirculations through the gap. In the case of a racetrack configuration, its is significant but not as critical, since the presence of the electron beam focuses the ions and lengthens the lifetime of the ion channel. It was established that pulsing the accelerating gap perturbs the IFR channel. However, for the parameters studied, the lifetime is long enough to allow at least four beam recirculations in a spiral device. In addition, cusp fields positioned upstream and downstream from the gap prevent it from perturbing the IFR channel

  9. The structural properties of CdS deposited by chemical bath deposition and pulsed direct current magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Lisco, F., E-mail: F.Lisco@lboro.ac.uk [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire, LE11 3TU (United Kingdom); Kaminski, P.M.; Abbas, A.; Bass, K.; Bowers, J.W.; Claudio, G. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire, LE11 3TU (United Kingdom); Losurdo, M. [Institute of Inorganic Methodologies and of Plasmas, IMIP-CNR, via Orabona 4, 70126 Bari (Italy); Walls, J.M. [Centre for Renewable Energy Systems Technology (CREST), School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire, LE11 3TU (United Kingdom)

    2015-05-01

    Cadmium sulphide (CdS) thin films were deposited by two different processes, chemical bath deposition (CBD), and pulsed DC magnetron sputtering (PDCMS) on fluorine doped-tin oxide coated glass to assess the potential advantages of the pulsed DC magnetron sputtering process. The structural, optical and morphological properties of films obtained by CBD and PDCMS were investigated using X-ray photoelectron spectroscopy, X-ray diffraction, scanning and transmission electron microscopy, spectroscopic ellipsometry and UV-Vis spectrophotometry. The as-grown films were studied and comparisons were drawn between their morphology, uniformity, crystallinity, and the deposition rate of the process. The highest crystallinity is observed for sputtered CdS thin films. The absorption in the visible wavelength increased for PDCMS CdS thin films, due to the higher density of the films. The band gap measured for the as-grown CBD-CdS is 2.38 eV compared to 2.34 eV for PDCMS-CdS, confirming the higher density of the sputtered thin film. The higher deposition rate for PDCMS is a significant advantage of this technique which has potential use for high rate and low cost manufacturing. - Highlights: • Pulsed DC magnetron sputtering (PDCMS) of CdS films • Chemical bath deposition of CdS films • Comparison between CdS thin films deposited by chemical bath and PDCMS techniques • High deposition rate deposition for PDCMS deposition • Uniform, pinhole free CdS thin films.

  10. Effect of laser pulse on alternative current arc discharge during laser-arc hybrid welding of magnesium alloy

    Science.gov (United States)

    Chen, Minghua; Xin, Lijun; Zhou, Qi; He, Lijia; Wu, Fufa

    2018-01-01

    The coupling effect between a laser and arc plasma was studied in situations in which the laser acts at the positive and negative waveforms of the arc discharge during the laser-arc hybrid welding of magnesium alloy. Using the methods of direct observation, high speed imaging, and spectral analysis, the surface status of weld seams, weld penetration depths, plasma behavior, and spectral characteristics of welding plasma were investigated, respectively. Results show that, as compared with the laser pulse acting at the negative waveform of the arc plasma discharge, a better weld seam formation can be achieved when the laser pulse acts at the positive waveform of the arc discharge. At the same time, the radiation intensity of Mg atoms in the arc plasma increases significantly. However, the weld penetration depth is weaker. The findings show that when the laser pulse is acting at the negative waveform of the arc plasma discharge, the position of the arc plasma discharge on the workpiece can be restrained by the laser action point, which improves the energy density of the welding arc.

  11. Large change in voltage at phase reversal improves biphasic defibrillation thresholds. Parallel-series mode switching.

    Science.gov (United States)

    Yamanouchi, Y; Mowrey, K A; Nadzam, G R; Hills, D G; Kroll, M W; Brewer, J E; Donohoo, A M; Wilkoff, B L; Tchou, P J

    1996-10-01

    Multiple factors contribute to an improved defibrillation threshold of biphasic shocks. The leading-edge voltage of the second phase may be an important factor in reducing the defibrillation threshold. We tested two experimental biphasic waveforms with large voltage changes at phase reversal. The phase 2 leading-edge voltage was twice the phase 1 trailing-edge voltage. This large voltage change was achieved by switching two capacitors from parallel to series mode at phase reversal. Two capacitors were tested (60/15 microfarads [microF] and 90/22.5 microF) and compared with two control biphasic waveforms for which the phase 1 trailing-edge voltage equaled the phase 2 leading-edge voltage. The control waveforms were incorporated into clinical (135/135 microF) or investigational devices (90/90 microF). Defibrillation threshold parameters were evaluated in eight anesthetized pigs by use of a nonthoracotomy transvenous lead to a can electrode system. The stored energy at the defibrillation threshold (ion joules) was 8.2 +/- 1.5 for 60/15 microF (P voltage changes at phase reversal caused by parallel-series mode switching appeared to improve the ventricular defibrillation threshold in a pig model compared with a currently available biphasic waveform. The 60/15-microF capacitor performed as well as the 90/ 22.5-microF capacitor in the experimental waveform. Thus, smaller capacitors may allow reduction in device size without sacrificing defibrillation threshold energy requirements.

  12. Pulse plating

    CERN Document Server

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  13. Numerical investigation on the dynamics and evolution mechanisms of multiple-current-pulse behavior in homogeneous helium dielectric-barrier discharges at atmospheric pressure

    Science.gov (United States)

    Zhang, Yuhui; Ning, Wenjun; Dai, Dong

    2018-03-01

    A systematic investigation on the dynamics and evolution mechanisms of multiple-current-pulse (MCP) behavior in homogeneous dielectric barrier discharge (HDBD) is carried out via fluid modelling. Inspecting the simulation results, two typical discharge regimes, namely the MCP-Townsend regime and MCP-glow regime, are found prevailing in MCP discharges, each with distinctive electrical and dynamic properties. Moreover, the evolution of MCP behavior with external parameters altering are illustrated and explicitly discussed. It is revealed that the discharge undergoes some different stages as external parameters vary, and the discharge in each stage follows a series of distinctive pattern in morphological characteristics and evolution trends. Among those stages, the pulse number per half cycle is perceived to observe non-monotonic variations with applied voltage amplitude (Vam) and gap width (dg) increasing, and a merging effect among pulses, mainly induced by the enhanced contribution of sinusoidal component to the total current, is considered responsible for such phenomenon. The variation of incipient discharge peak phase (Φpm) is dominated by the value of Vam as well as the proportion of total applied voltage that drops across the gas gap. Moreover, an abnormal, dramatic elevation in Jpm with dg increasing is observed, which could be evinced by the strengthened glow discharge structure and therefore enhanced space charge effect.

  14. Numerical investigation on the dynamics and evolution mechanisms of multiple-current-pulse behavior in homogeneous helium dielectric-barrier discharges at atmospheric pressure

    Directory of Open Access Journals (Sweden)

    Yuhui Zhang

    2018-03-01

    Full Text Available A systematic investigation on the dynamics and evolution mechanisms of multiple-current-pulse (MCP behavior in homogeneous dielectric barrier discharge (HDBD is carried out via fluid modelling. Inspecting the simulation results, two typical discharge regimes, namely the MCP-Townsend regime and MCP-glow regime, are found prevailing in MCP discharges, each with distinctive electrical and dynamic properties. Moreover, the evolution of MCP behavior with external parameters altering are illustrated and explicitly discussed. It is revealed that the discharge undergoes some different stages as external parameters vary, and the discharge in each stage follows a series of distinctive pattern in morphological characteristics and evolution trends. Among those stages, the pulse number per half cycle is perceived to observe non-monotonic variations with applied voltage amplitude (Vam and gap width (dg increasing, and a merging effect among pulses, mainly induced by the enhanced contribution of sinusoidal component to the total current, is considered responsible for such phenomenon. The variation of incipient discharge peak phase (Φpm is dominated by the value of Vam as well as the proportion of total applied voltage that drops across the gas gap. Moreover, an abnormal, dramatic elevation in Jpm with dg increasing is observed, which could be evinced by the strengthened glow discharge structure and therefore enhanced space charge effect.

  15. A biphasic model for bleeding in soft tissue

    Science.gov (United States)

    Chang, Yi-Jui; Chong, Kwitae; Eldredge, Jeff D.; Teran, Joseph; Benharash, Peyman; Dutson, Erik

    2017-11-01

    The modeling of blood passing through soft tissues in the body is important for medical applications. The current study aims to capture the effect of tissue swelling and the transport of blood under bleeding or hemorrhaging conditions. The soft tissue is considered as a non-static poro-hyperelastic material with liquid-filled voids. A biphasic formulation effectively, a generalization of Darcy's law-is utilized, treating the phases as occupying fractions of the same volume. The interaction between phases is captured through a Stokes-like friction force on their relative velocities and a pressure that penalizes deviations from volume fractions summing to unity. The soft tissue is modeled as a hyperelastic material with a typical J-shaped stress-strain curve, while blood is considered as a Newtonian fluid. The method of Smoothed Particle Hydrodynamics is used to discretize the conservation equations based on the ease of treating free surfaces in the liquid. Simulations of swelling under acute hemorrhage and of draining under gravity and compression will be demonstrated. Ongoing progress in modeling of organ tissues under injuries and surgical conditions will be discussed.

  16. Functional properties of the isomorphic biphasic algal life cycle.

    Science.gov (United States)

    Thornber, Carol S

    2006-10-01

    Many species of marine algae have life cycles that involve multiple separate, free-living phases that frequently differ in ploidy levels. These complex life cycles have received increasing scientific attention over the past few decades, due to their usefulness for both ecological and evolutionary studies. I present a synthesis of our current knowledge of the ecological functioning and evolutionary implications of the isomorphic, biphasic life cycles commonly found in many species of marine algae. There are both costs and benefits to life cycles with 2 morphologically similar but separate, free-living phases that differ in ploidy levels (haploids and diploids). Evolutionary theory predicts that the existence of subtle yet important differences between the phases may be what allows these life cycles to be maintained. Different phases of the same species can vary in abundance, in demographic parameters such as mortality and fecundity, in their physiology, and in their resistance to herbivory. Some taxonomic groups within the red algae have received significant attention toward these issues, while our knowledge of these properties for brown and green algae remains limited.

  17. Stoichiometric implications of a biphasic life cycle.

    Science.gov (United States)

    Tiegs, Scott D; Berven, Keith A; Carmack, Douglas J; Capps, Krista A

    2016-03-01

    Animals mediate flows of elements and energy in ecosystems through processes such as nutrient sequestration in body tissues, and mineralization through excretion. For taxa with biphasic life cycles, the dramatic shifts in anatomy and physiology that occur during ontogeny are expected to be accompanied by changes in body and excreta stoichiometry, but remain little-explored, especially in vertebrates. Here we tested stoichiometric hypotheses related to the bodies and excreta of the wood frog (Lithobates sylvaticus) across life stages and during larval development. Per-capita rates of nitrogen (N) and phosphorus (P) excretion varied widely during larval ontogeny, followed unimodal patterns, and peaked midway through development (Taylor-Kollros stages XV and XII, respectively). Larval mass did not increase steadily during development but peaked at stage XVII and declined until the termination of the experiment at stage XXII. Mass-specific N and P excretion rates of the larvae decreased exponentially during development. When coupled with population-biomass estimates, population-level excretion rates were greatest at stages VIII-X. Percent carbon (C), N, and C:N of body tissue showed weak trends across major life stages; body P and C:P, however, increased sixfold during development from egg to adult. Our results demonstrate that intraspecific ontogenic changes in nutrient contents of excretion and body tissues can be significant, and that N and P are not always excreted proportionally throughout life cycles. These results highlight the dynamic roles that species play in ecosystems, and how the morphological and physiological changes that accompany ontogeny can influence ecosystem-level processes.

  18. RESULTS OF CALCULATION-EXPERIMENTAL INVESTIGATIONS OF ELECTRO-THERMAL RESISTIBILITY OF SHEET STEEL SAMPLES TO ACTION OF RATIONED COMPONENTS OF PULSED CURRENT OF ARTIFICIAL LIGHTING

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2016-06-01

    Full Text Available Purpose. Calculation and experimental researches of the electro-thermal resistibility of the steel sheet samples to action standard pulse current components of the artificial lightning with amplitude-time parameters (ATP, corresponded the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. Methodology. Electrophysics bases of technique of high tensions and large impulsive currents (LIC, and also scientific and technical bases of planning of devices of high-voltage impulsive technique and measuring in them LIC. Сurrent amplitude ImA=±200 kA (with a tolerance of ±10 %; current action integral JA=2∙106 A2•s (with a tolerance of ±20 %; time, corresponding to the amplitude of the current ImA, tmA≤50 microseconds; the duration of the current flow τpA≤500 microseconds. Results. The results of the evaluation of the calculated and experimental studies of electro-thermal resistance of the samples of plates measuring 0,5 m  0,5 m stainless steel 1 mm thickness to the action on them artificial lightning impulse currents with rationed ATP on the requirements of normative documents of USA for SAE ARP 5412 & SAE ARP 5416. A pulse A- component have a first amplitude 192 kA, the corresponding time of 34 μs, and the duration aperiodic component amplitude 804 A, corresponding to the time 9 ms. It has been shown that the long C- component current of artificial lightning can lead to keyhole these samples. The diameter of the holes in this thin steel sheet, which is formed during the flow of current C- components can reach 15 mm. The results of calculation and experiment agree within 28 %. Originality. For the first time in world practice on the generator large pulsed currents experimental studies of resistibility of sheet steel samples to the action of artificial lightning currents with critical parameters. Practical value. Using the results obtained in the practice of lightning protection will significantly improve the

  19. Effect of Continuous and Pulsed Current on the Metallurgical and Mechanical Properties of Gas Tungsten Arc Welded AISI 4340 Aeronautical and AISI 304 L Austenitic Stainless Steel Dissimilar Joints

    OpenAIRE

    Arivarasu, Moganraj; Ramkumar Kasinath, Devendranath; Natarajan, Arivazhagan

    2015-01-01

    In this research work, the weldability of low alloyed AISI 4340 aeronautical steel and AISI 304L austenitic stainless steel joined by continuous current (CC) and pulsed current (PC) gas tungsten arc welding (GTAW) techniques, using ER309L and ERNiCr-3 filler metals was investigated. The main focus of the study involves the investigation on the effect of continuous and pulsed current mode of GTA welding process on the metallurgical and mechanical properties of these dissimilar weldments. Micro...

  20. Preliminary investigation on the use of low current pulsed power Z-pinch plasma devices for the study of early stage plasma instabilities

    Science.gov (United States)

    Kaselouris, E.; Dimitriou, V.; Fitilis, I.; Skoulakis, A.; Koundourakis, G.; Clark, E. L.; Chatzakis, J.; Bakarezos, Μ; Nikolos, I. K.; Papadogiannis, N. A.; Tatarakis, M.

    2018-01-01

    This article addresses key features for the implementation of low current pulsed power plasma devices for the study of matter dynamics from the solid to the plasma phase. The renewed interest in such low current plasma devices lies in the need to investigate methods for the mitigation of prompt seeding mechanisms for the generation of plasma instabilities. The low current when driven into thick wires (skin effect mode) allows for the simultaneous existence of all phases of matter from solid to plasma. Such studies are important for the concept of inertial confinement fusion where the mitigation of the instability seeding mechanisms arising from the very early moments within the target’s heating is of crucial importance. Similarly, in the magnetized liner inertial fusion concept it is an open question as to how much surface non-uniformity correlates with the magneto-Rayleigh-Taylor instability, which develops during the implosion. This study presents experimental and simulation results, which demonstrate that the use of low current pulsed power devices in conjunction with appropriate diagnostics can be important for studying seeding mechanisms for the imminent generation of plasma instabilities in future research.

  1. Subionospheric propagation and peak currents of preliminary breakdown pulses before negative cloud-to-ground lightning discharges

    Czech Academy of Sciences Publication Activity Database

    Kolmašová, Ivana; Santolík, Ondřej; Farges, T.; Cummer, S. A.; Lán, Radek; Uhlíř, Luděk

    2016-01-01

    Roč. 43, č. 3 (2016), s. 1382-1391 ISSN 0094-8276 R&D Projects: GA ČR(CZ) GA14-31899S Grant - others:AV ČR(CZ) AP1401 Program:Akademická prémie - Praemium Academiae Institutional support: RVO:68378289 Keywords : preliminary breakdown pulses * subionospheric propagation * FDTD model Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 4.253, year: 2016 http://onlinelibrary.wiley.com/doi/10.1002/2015GL067364/full

  2. Electrodeposition of Gold to Conformally Fill High Aspect Ratio Nanometric Silicon Grating Trenches: A Comparison of Pulsed and Direct Current Protocols

    Science.gov (United States)

    Znati, Sami A.; Chedid, Nicholas; Miao, Houxun; Chen, Lei; Bennett, Eric E.; Wen, Han

    2016-01-01

    Filling high-aspect-ratio trenches with gold is a frequent requirement in the fabrication of x-ray optics as well as micro-electronic components and other fabrication processes. Conformal electrodeposition of gold in sub-micron-width silicon trenches with an aspect ratio greater than 35 over a grating area of several square centimeters is challenging and has not been described in the literature previously. A comparison of pulsed plating and constant current plating led to a gold electroplating protocol that reliably filled trenches for such structures. PMID:27042384

  3. Differential B-dot and D-dot monitors for current and voltage measurements on a 20-MA 3-MV pulsed-power accelerator.

    Energy Technology Data Exchange (ETDEWEB)

    Shoup, Roy Willlam (ITT Industries, Albuquerque, NM); Gilliland, Terrance Leo (Ktech Corporation, Albuquerque, NM); Lee, James R.; Speas, Christopher Shane; Kim, Alexandre A. (High Current Electronic Institute, Russian Academy of Sciences, Tomsk, Russia); Struve, Kenneth William; York, Mathew William; Leifeste, Gordon T.; Rochau, Gregory Alan; Sharpe, Arthur William; Stygar, William A.; Porter, John Larry Jr.; Wagoner, Tim C. (Ktech Corporation, Albuquerque, NM); Reynolds, Paul Gerard (Team Specialty Products Corporation, Albuquerque, NM); Slopek, Jeffrey Scott (Ktech Corporation, Albuquerque, NM); Moore, William B. S.; Dinwoodie, Thomas Albert (Ktech Corporation, Albuquerque, NM); Woodring, R. M. (Ktech Corporation, Albuquerque, NM); Broyles, Robin Scott (Ktech Corporation, Albuquerque, NM); Mills, Jerry Alan; Melville, J. A. (Prodyn Technologies Incorporated, Albuquerque, NM); Dudley, M. E. (Ktech Corporation, Albuquerque, NM); Androlewicz, K. E. (Ktech Corporation, Albuquerque, NM); Mourning, R. W. (Ktech Corporation, Albuquerque, NM); Moore, J. K. (Ktech Corporation, Albuquerque, NM); Serrano, Jason Dimitri (Ktech Corporation, Albuquerque, NM); Ives, H. C. (EG& G, Albuquerque, NM); Johnson, M. F. (Team Specialty Products Corporation, Albuquerque, NM); Peyton, B. P. (Ktech Corporation, Albuquerque, NM); Leeper, Ramon Joe; Savage, Mark Edward; Donovan, Guy Louis; Spielman, R. B. (Ktech Corporation, Albuquerque, NM); Seamen, Johann F.

    2007-12-01

    We have developed a system of differential-output monitors that diagnose current and voltage in the vacuum section of a 20-MA 3-MV pulsed-power accelerator. The system includes 62 gauges: 3 current and 6 voltage monitors that are fielded on each of the accelerator's 4 vacuum-insulator stacks, 6 current monitors on each of the accelerator's 4 outer magnetically insulated transmission lines (MITLs), and 2 current monitors on the accelerator's inner MITL. The inner-MITL monitors are located 6 cm from the axis of the load. Each of the stack and outer-MITL current monitors comprises two separate B-dot sensors, each of which consists of four 3-mm-diameter wire loops wound in series. The two sensors are separately located within adjacent cavities machined out of a single piece of copper. The high electrical conductivity of copper minimizes penetration of magnetic flux into the cavity walls, which minimizes changes in the sensitivity of the sensors on the 100-ns time scale of the accelerator's power pulse. A model of flux penetration has been developed and is used to correct (to first order) the B-dot signals for the penetration that does occur. The two sensors are designed to produce signals with opposite polarities; hence, each current monitor may be regarded as a single detector with differential outputs. Common-mode-noise rejection is achieved by combining these signals in a 50-{Omega} balun. The signal cables that connect the B-dot monitors to the balun are chosen to provide reasonable bandwidth and acceptable levels of Compton drive in the bremsstrahlung field of the accelerator. A single 50-{omega} cable transmits the output signal of each balun to a double-wall screen room, where the signals are attenuated, digitized (0.5-ns/sample), numerically compensated for cable losses, and numerically integrated. By contrast, each inner-MITL current monitor contains only a single B-dot sensor. These monitors are fielded in opposite-polarity pairs. The two

  4. Biphasic Malignant Pleural Mesothelioma Masquerading as a Primary Skeletal Tumor

    Directory of Open Access Journals (Sweden)

    James Benjamin Gleason

    2016-01-01

    Full Text Available Biphasic malignant pleural mesothelioma is a rare malignant tumor, usually presenting as a pleural-based mass in a patient with history of chronic asbestos exposure. We herein report a case of a 41-year-old man who presented with chest pain and had a chest computed tomography (CT scan suggestive of a primary skeletal tumor originating from the ribs (chondrosarcoma or osteosarcoma, with no history of asbestos exposure. CT-guided core needle biopsies were diagnosed as malignant sarcomatoid mesothelioma. Surgical resection and chest wall reconstruction were performed, confirming the diagnosis and revealing a secondary histologic component (epithelioid, supporting the diagnosis of biphasic malignant mesothelioma.

  5. Impact of low-frequency pulsed electromagnetic fields and interference currents in the formation of heterotopic ossification after total hip instalation in the hip joint

    Directory of Open Access Journals (Sweden)

    Ivković S.

    2015-01-01

    Full Text Available Due to the extension of life expectancy, the number of elderly people increases, and thus the number of disease and injuries of the locomotor system, especially the hip joint. One of the persistent trend is an increasing trend in the number of patients with coxarthrosis and implanted total hip endoprosthesis. One of the postoperative complications that occurred after implantation a total hip endoprosthesis is heterotopic ossification (HO. HO is the most common complication that occurs after the implantation a total hip endoprosthesis with recorded cases in the range of 9-90%. HO are insufficiently understood phenomenon, which is characterized by the formation of bone in periarticular tissues. We prospectively followed patients who implanted total hip endoprostheses in the department of orthopedics ZC in Kos. Mitrovica in 2008. and 2009. year. We examined the influence of physical agents on the prevention of HO near the hip joint. In these patients the treatment was carried out kinesiotherapeutic at the Center for Rehabilitation Health Center Kosovska Mitrovica, as well as pulse therapy low frequency magnetic field frequency of 30 Hz, 30 minutes, 8 mT intensity and 15 minutes interferential current, 0-100 Hz frequency. All patients were on the rehabilitation of one month (20 days. Based on this research we confirmed the assumption that the use of low frequency pulsed magnetic fields, interference currents and kinesitherapy prevents HO in patients after implantation of total endoprosthesis of the hip joint.

  6. Investigations on the microstructure and mechanical properties of multi-pass pulsed current gas tungsten arc weldments of Monel 400 and Hastelloy C276

    International Nuclear Information System (INIS)

    Devendranath Ramkumar, K.; Joshi, Vaibhav; Pandit, Savyasachi; Agrawal, Meghna; Kumar, Oza Smit; Periwal, Saurabh; Manikandan, M.; Arivazhagan, N.

    2014-01-01

    Highlights: • For the first time study on the dissimilar weldments of Monel 400 and Hastelloy C276. • Pensive structure – property relationships of these weldments. • Improved micro-structural features. • Better ductility of the weldments through bend test results. - Abstract: This research article reported the weldability, microstructure and mechanical properties of the dissimilar combinations of nickel alloys such as Monel 400 and Hastelloy C276. Multi-pass pulsed current gas tungsten arc (PCGTA) welding was employed for joining these dissimilar metals using ERNiCrMo-3 filler. Interface microstructures showed the absence of unmixed zone at the HAZ of both the sides. It was evident from the studies that all the tensile failures occurred at Monel 400 side. The average impact toughness portrayed by these dissimilar weldments was found to be 41 J. Bend test results showed that these dissimilar combinations offer augmented ductility. The outcomes of the study substantiated the use of current pulsing for the successful joints of Monel 400 and Hastelloy C276 by correlating the mechanical and metallurgical properties

  7. Radiative neutron capture as a counting technique at pulsed spallation neutron sources: a review of current progress

    Science.gov (United States)

    Schooneveld, E. M.; Pietropaolo, A.; Andreani, C.; Perelli Cippo, E.; Rhodes, N. J.; Senesi, R.; Tardocchi, M.; Gorini, G.

    2016-09-01

    Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

  8. Cardiovascular responses to lead are biphasic, while methylmercury, but not inorganic mercury, monotonically increases blood pressure in rats.

    Science.gov (United States)

    Wildemann, Tanja M; Mirhosseini, Naghmeh; Siciliano, Steven D; Weber, Lynn P

    2015-02-03

    Cardiovascular diseases, such as heart attack and stroke, are the major cause of death worldwide. It is well known that a high number of environmental and physiological risk factors contribute to the development of cardiovascular diseases. Although risk factors are additive, increased blood pressure (hypertension) is the greatest risk factor. Over the last two decades, a growing number of epidemiological studies associate environmental exposure to lead or mercury species with hypertension. However, cardiovascular effects beyond blood pressure are rarely studied and thresholds for effect are not yet clear. To explore effects of lead or mercury species on the cardiovascular system, normal male Wistar rats were exposed to a range of doses of lead, inorganic mercury or methylmercury through the drinking water for four weeks. High-resolution ultrasound was used to measure heart and vascular function (carotid artery blood flow) at baseline and at the end of the exposure, while blood pressure was measured directly in the femoral artery at the end of the 4-week exposure. After 4 weeks, blood pressure responses to lead were biphasic. Low lead levels decreased blood pressure, dilated the carotid artery and increased cardiac output. At higher lead doses, rats had increased blood pressure. In contrast, methylmercury-exposed rats had increased blood pressure at all doses despite dilated carotid arteries. Inorganic mercury did not show any significant cardiovascular effects. Based on the current study, the benchmark dose level 10% (BMDL10s) for systolic blood pressure for lead, inorganic mercury and methylmercury are 1.1, 1.3 and 1.0 μg/kg-bw/d, respectively. However, similar total mercury blood levels attributed to inorganic mercury or methylmercury produced strikingly different results with inorganic mercury having no observable effect on the cardiovascular system but methylmercury increasing systolic and pulse pressures. Therefore, adverse cardiovascular effects cannot be

  9. The Effect of Constant and Pulsed Current Gas Tungsten Arc Welding on Joint Properties of 2205 Duplex Stainless Steel to 316L Austenitic Stainless Steel

    Science.gov (United States)

    Neissi, R.; Shamanian, M.; Hajihashemi, M.

    2016-05-01

    In this study, dissimilar 316L austenitic stainless steel/2205 duplex stainless steel (DSS) joints were fabricated by constant and pulsed current gas tungsten arc welding process using ER2209 DSS as a filler metal. Microstructures and joint properties were characterized using optical and electron scanning microscopy, tensile, Charpy V-notch impact and micro-hardness tests, and cyclic polarization measurements. Microstructural observations confirmed the presence of chromium nitride and delta ferrite in the heat-affected zone of DSS and 316L, respectively. In addition, there was some deviation in the austenite/ferrite ratio of the surface welding pass in comparison to the root welding pass. Besides having lower pitting potential, welded joints produced by constant current gas tungsten arc welding process, consisted of some brittle sigma phase precipitates, which resulted in some impact energy reduction. The tensile tests showed high tensile strength for the weld joints in which all the specimens were broken in 316L base metal.

  10. Displacement and emission currents from PLZT 8/65/35 and 4/95/5 excited by a negative voltage pulse at the rear electrode

    CERN Document Server

    Benedek, G; Handerek, J; Marchesini, S; De Martinis, C; Riege, H; Scurati, A

    1997-01-01

    It is shown that non-prepoled PLZT ceramics, both in ferroelectric and antiferroelectric phase, emit intense current bursts when a negative exciting voltage is applied to the rear surface of the cathode. The spontaneous polarization induced in the bulk by applying the field through the cathode disk, creates a sheet of negative charge on the diode boundary of the ferroelectric. This, in turn, induces such a high electric field at the diode dielectric surface that electrons are ejected out from the ceramic surface into the vacuum. The coherent behaviour of the displacement and emitted current shows clearly that the emission is due to a variation of spontaneous polarization. A second effect generated by the application of the high voltage pulse at the rear side is the formation of a surface plasma. Applying a positive voltage to the anode, electrons are readily transferred through the diode gap.

  11. Kinetics of the magnetization reversal in permalloy-niobium microstrips under the effect of a pulsed magnetic field and an electric current

    Science.gov (United States)

    Egorov, S. V.; Uspenskaya, L. S.

    2016-02-01

    The kinetics of magnetization reversal in bilayer permalloy-niobium microstrips under the effect of both a pulsed magnetic field and an electric current has been experimentally studied. These two cases turn out to be fundamentally different in the types of arising magnetic structures and in the dynamic characteristics of the processes. Such difference is especially striking at low temperatures. An anomalously high rate of the processes under study is observed. According to the suggested qualitative explanation, this effect is due to nonlinear excitations appearing in front of the moving domain wall if the applied electric current lowers the barriers for its motion. For achieving the final conclusions, more accurate quantitative analysis is needed.

  12. Pulse Pattern-Modulated Strategy for Harmonic Current Components Reduction in Three-Phase AC–DC Converters

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2016-01-01

    Generated harmonic current as a consequence of employing power electronics converter is known as an important power quality issue in distribution networks. From industry point of view complying with international standards is mandatory, however cost and efficiency are two other important features......, which need to be considered in order to be competitive in the market. Therefore, having a flexibility to meet various requirements imposed by the standard recommendations or costumer needs is at most desirable. This makes the generated harmonic current mitigation a challenging task especially with three-phase...... diode bridge rectifier, which still is preferred in many power electronic systems. This paper addresses a novel current modulation strategy using a single-switch boost three-phase diode bridge rectifier. The proposed method can selectively mitigate current harmonics, which makes it suitable...

  13. Investigation of the Current Turn-off Characteristics of a GTO Thyristor in an Inductive Pulse Forming Network

    National Research Council Canada - National Science Library

    Vineyard, Gerald E

    2008-01-01

    .... The test circuit consisted of a high-voltage capacitor bank, a wire-wound inductor, the GTO thyristor with control circuitry, and instrumentation to measure voltages and currents in the circuit...

  14. Effects of nitrogen and pulsed mean welding current in AISI 316 austenitic stainless steel solidification cracks; Efecto del nitrogeno y la corriente media pulsada de soldadura en la formacion de grietas de solidificacion en aceros inoxidables AISI 316L

    Energy Technology Data Exchange (ETDEWEB)

    Trevisan, R. E.; Braga, E.; Fals, H. C.

    2002-07-01

    An analysis of the influence of nitrogen concentration in the weld zone and the pulsed mean welding current in the solidification crack formation is presented in this paper. The AISI 316L austenitic stainless steel was employed as the metal base. The welding was done using CC+ pulsed flux cored are welding process and AWS E316L wire type. The tests were conducted using CO{sub 2} shielding gas with four different nitrogen levels (0,5; 10 and 15%) in order to induce different nitrogen weld metal concentrations. The pulsed mean welding current was varied in three levels and the. Transvarestraint tangential strain test was fixed of 5%. The results showed that the solidification cracking decreased as the pulsed mean welding current increase. It was also verified that an increase of the weld zone nitrogen level was associated with a decrease in both the total length of solidification crack and the amount of {delta} ferrite. (AUthor) 20 refs.

  15. In vitro study on biomineralization of biphasic calcium phosphate ...

    Indian Academy of Sciences (India)

    Abstract. In this study, we report the preparation of a bone graft material, having cylindrical shape, containing biphasic calcium phosphate (BCP), gelatin (G), chitosan (C) and Terminalia chebula (TC) extract. TC extract was used as a crosslinker that gives stability to bone graft when it is placed in SBF. The graft was stable in ...

  16. Biphasic Clinical Course Among Kenyan Children With Cerebral ...

    African Journals Online (AJOL)

    Biphasic Clinical Course Among Kenyan Children With Cerebral Malaria. ... African Journal of Neurological Sciences ... Method We undertook a retrospective study of children admitted to Kilifi District Hospital with a history of impaired consciousness and Falciparum infection between January 1994 and December 2004.

  17. Biphasic Clinical Course Among Kenyan Children With Cerebral ...

    African Journals Online (AJOL)

    Background Cerebral malaria is the most severe neurological complication of Falciparum malaria. It is associated with a significant risk of death and neurological sequelae. A biphasic clinical picture is associated with an even greater risk of neurological sequelae. Objective To examine the incidence and clinical ...

  18. In vitro study on biomineralization of biphasic calcium phosphate ...

    Indian Academy of Sciences (India)

    In this study, we report the preparation of a bone graft material, having cylindrical shape, containing biphasic calcium phosphate (BCP), gelatin (G), chitosan (C) and Terminalia chebula (TC) extract. TC extract was used as a crosslinker that gives stability to bone graft when it is placed in SBF. The graft was stable in the SBF ...

  19. Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator.

    Science.gov (United States)

    Brugada, J; Herse, B; Sandsted, B; Michel, U; Schubert, B D; Hahn, S J

    2001-10-01

    Improvements in the size and shape of implantable cardioverter defibrillators (ICDs) might be obtained by using one capacitor instead of the series connection of two capacitors traditionally used in ICDs. The aim of this study was to determine whether a biphasic waveform delivered from a single 336 microF capacitor had the same defibrillation efficacy as a standard biphasic waveform. Randomized, paired defibrillation threshold testing was acutely performed in 54 patients undergoing ICD implantation. A standard 140 microF 80% tilt biphasic waveform (two 280 microF capacitors connected in series) was compared with an experimental biphasic waveform delivered from a single 336 microF capacitor at either 60% tilt (33 patients) or 80% tilt (21 patients). All waveforms had a 60/40 phase1/phase2 duration ratio. Compared with the standard waveform, the 60% tilt experimental waveform had a lower delivered energy (6.7 +/- 2.8 vs 7.9 +/- 3.3 joules, Pvoltage (218 +/- 43 vs 333 +/- 68 V, Pvoltage (234 +/- 44 vs 302 +/- 51 V, P<0.01) and a much longer pulse duration (25.7 +/- 2.5 vs 1.13 +/- 1 ms, P<0.01). Waveforms delivered from a large capacitance are feasible but require a lower tilt. This technique may allow smaller, thinner ICDs without jeopardizing defibrillation success.

  20. Pulse pattern modulated strategy for harmonic current components reduction in three-phase AC-DC converters

    DEFF Research Database (Denmark)

    Davari, Pooya; Zare, Firuz; Blaabjerg, Frede

    2015-01-01

    Generated harmonic current as a consequence of employing power electronics converter is known as an important power quality issue in distribution networks. From industry point of view complying with international standards is mandatory, however cost and efficiency are two other important features...

  1. Electrochemically enhanced reduction of hexavalent chromium in contaminated clay: Kinetics, energy consumption, and application of pulse current

    DEFF Research Database (Denmark)

    Sun, Tian Ran; Pamukcu, Sibel; Ottosen, Lisbeth M.

    2015-01-01

    Electrochemically enhanced reduction of Cr(VI) in clay medium is a technique based on inputting extra energy into the clay to drive the favorable redox reaction. In this study, the reducing reagent Fe(II) was transported into Cr(VI) spiked kaolinite clay by direct current to investigate...

  2. [High current microsecond pulsed hollow cathode lamp excited ionic fluorescence spectrometry of alkaline earth elements in inductively coupled plasma with a Fassel-torch].

    Science.gov (United States)

    Zhang, Shao-Yu; Gong, Zhen-Bin; Huang, Ben-Li

    2006-02-01

    High current microsecond pulsed hollow cathode lamp (HCMP-HCL) excited ionic fluorescence spectrometry (IFS) of alkaline earth elements in inductively coupled plasma (ICP) with a Fassel-torch has been investigated. In wide condition ranges only IFS was observed, whilst atomic fluorescence spectrometry (AFS) was not detectable. More intense ionic fluorescence signal was observed at lower observation heights and at lower incident RF powers. Without introduction of any reduction organic gases into the ICP, the limit of detection (LOD, 3sigma) of Ba was improved by 50-fold over that of a conventional pulsed (CP) HCL with the Baird sleeve-extended torch. For Ca and Sr, the LODs by HCMP-HCL-ICP-IFS and CP-HCL-ICP-AFS show no significant difference. Relative standard deviations were 0.6%-1.4% (0.1-0.2 microg x mL(-1), n = 10) for 5 ionic fluorescence lines. Preliminary studies showed that the intensity of ionic fluorescence could be depressed in the presence of K, Al and P.

  3. Time-dependent flux from pulsed neutrons revealed by superconducting Nb current-biased kinetic inductance detector with 10B converter operated at 4 K

    International Nuclear Information System (INIS)

    Miyajima, Shigeyuki; Narukami, Yoshito; Shishido, Hiroaki; Yoshioka, Naohito; Ishida, Takekazu; Fujimaki, Akira; Hidaka, Mutsuo; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Arai, Masatoshi

    2015-01-01

    We have demonstrated a new superconducting detector for a neutron based on Nb superconductor meanderline with a 10 B conversion layer. We use a current-biased kinetic inductance detector (CB-KID), which is composed of a meanderline, for detection of a neutron with high spatial resolution and fast response. The thickness of Nb meanderlines is 40 nm and widths are 3 μm, 1 μm, and 0.6 μm. The CB-KIDs are fabricated at the center of the Si chip of the size 22 mm × 22 mm and the total area of CB-KIDs covers 8 mm × 8 mm. The chip was cooled to a temperature lower than 4 K below the transition temperature of Nb using a Gifford-McMahon (GM) cryocooler. The Nb CB-KIDs with a 10 B conversion layer output the voltage by irradiating pulsed neutrons at the material life science experimental facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC) center. The response time of CB-KIDs is about a few tens ns. We have also obtained the time dependence of neutron flux generated from pulsed neutrons using a CB-KID. Experimental results were in good agreement with the simulated results. (author)

  4. Temperature-dependent leakage current behavior of epitaxial Bi0.5Na0.5TiO3-based thin films made by pulsed laser deposition

    Science.gov (United States)

    Hejazi, M. M.; Safari, A.

    2011-11-01

    This paper discusses the electrical conduction mechanisms in a 0.88 Bi0.5Na0.5TiO3-0.08 Bi0.5K0.5TiO3-0.04 BaTiO3 thin film in the temperature range of 200-350 K. The film was deposited on a SrRuO3/SrTiO3 substrate by pulsed laser deposition technique. At all measurement temperatures, the leakage current behavior of the film matched well with the Lampert's triangle bounded by three straight lines of different slopes. The relative location of the triangle sides varied with temperature due to its effect on the density of charge carriers and un-filled traps. At low electric fields, the ohmic conduction governed the leakage mechanism. The calculated activation energy of the trap is 0.19 eV implying the presence of shallow traps in the film. With increasing the applied field, an abrupt increase in the leakage current was observed. This was attributed to a trap-filling process by the injected carriers. At sufficiently high electric fields, the leakage current obeyed the Child's trap-free square law suggesting the space charge limited current was the dominant mechanism.

  5. Pulsed and continuous radiofrequency current adjacent to the cervical dorsal root ganglion of the rat induces late cellular activity in the dorsal horn.

    NARCIS (Netherlands)

    Zundert, J. van; Louw, A.J. de; Joosten, E.A.J.; Kessels, A.G.H.; Honig, W.; Dederen, P.J.W.C.; Veening, J.G.; Vles, J.S.; Kleef, M. van

    2005-01-01

    BACKGROUND: Pulsed radiofrequency treatment has recently been described as a non-neurodestructive or minimally neurodestructive alternative to radiofrequency heat lesions. In clinical practice long-lasting results of pulsed radiofrequency treatment adjacent to the cervical dorsal root ganglion for

  6. Monophasic Pulsed 200-?A Current Promotes Galvanotaxis With Polarization of Actin Filament and Integrin ?2?1 in Human Dermal Fibroblasts

    OpenAIRE

    Uemura, Mikiko; Maeshige, Noriaki; Koga, Yuka; Ishikawa-Aoyama, Michiko; Miyoshi, Makoto; Sugimoto, Masaharu; Terashi, Hiroto; Usami, Makoto

    2016-01-01

    Objective: The monophasic pulsed microcurrent is used to promote wound healing, and galvanotaxis regulation has been reported as one of the active mechanisms in the promotion of tissue repair with monophasic pulsed microcurrent. However, the optimum monophasic pulsed microcurrent parameters and intracellular changes caused by the monophasic pulsed microcurrent have not been elucidated in human dermal fibroblasts. The purpose of this study was to investigate the optimum intensity for promoting...

  7. Design of optimized RC-CR filters for current-pulse operation of fission counters and high sensitivity fission counters for high gamma backgrounds

    International Nuclear Information System (INIS)

    de Lorenzo, J.T.

    1976-01-01

    A calculational procedure was developed to design RC-CR filters for processing current pulses from fission counters in a gamma background ranging from 10 5 to 6 x 10 6 R/hr. The effects of noise from the gamma background and the input preamplifier and of the time constant of the fission counter and input cable were studied. Analytical results were in close agreement with experimental data. A pole-zero network was examined as a means of compensating for the time constant of the fission counter and input cable, but its improvement was insignificant. The procedure was expanded to design a high sensitivity, gamma--tolerant fission counter (approximately 10 counts sec -1 nv -1 at 10 5 R/hr), and the result was a conceptual design with a performance almost equal to a recently developed high temperature fission counter

  8. Stress controlled pulsed direct current co-sputtered Al1−xScxN as piezoelectric phase for micromechanical sensor applications

    Directory of Open Access Journals (Sweden)

    Simon Fichtner

    2015-11-01

    Full Text Available Scandium alloyed aluminum nitride (Al1−xScxN thin films were fabricated by reactive pulsed direct current co-sputtering of separate scandium and aluminum targets with x ≤ 0.37. A significant improvement of the clamped transversal piezoelectric response to strain e31,f from −1.28 C/m2 to −3.01 C/m2 was recorded, while dielectric constant and loss angle remain low. Further, the built-in stress level of Al1−xScxN was found to be tuneable by varying pressure, Ar/N2 ratio, and Sc content. The thus resulting enhancement of the expectable signal to noise ratio by a factor of 2.1 and the ability to control built-in stress make the integration of Al1−xScxN as the piezoelectric phase of micro-electro-mechanical system sensor applications highly attractive.

  9. Fabrication of a metallic roll stamp with low internal stress and high hardness for large area display applications by a pulse reverse current electroforming process

    International Nuclear Information System (INIS)

    Kim, Joongeok; Han, Jungjin; Kim, Taekyung; Kang, Shinill

    2014-01-01

    With the increasing demand for large scale micro/nano components in the fields of display, energy and electrical devices, etc, the establishment of a roll imprinting process has become a priority. The fabrication of a roll stamp with high dimensional accuracy and uniformity is one of the key issues in the roll imprinting process, because the roll stamp determines the properties of the replicated micro/nano structures. In this study, a method to fabricate a metallic roll stamp with low internal stress, high flatness, and high hardness was proposed by a pulse reverse current (PRC) electroforming process. The effects of PRC electroforming processes on the internal stress, hardness, and grain size of the electroformed stamp were examined, and the optimum process conditions were suggested. As a practical example of the proposed method, various micro-patterns for electronic circuits were fabricated via the roll imprinting process using a PRC electroformed stamp. (paper)

  10. Calculated fraction of an incident current pulse that will be accelerated by an electron linear accelerator and comparisons with experimental data

    International Nuclear Information System (INIS)

    Alsmiller, R.G. Jr.; Alsmiller, F.S.; Lewis, T.A.

    1986-05-01

    In a series of previous papers, calculated results obtained using a one-dimensional ballistic model were presented to aid in the design of a prebuncher for the Oak Ridge Electron Linear Accelerator. As part of this work, a model was developed to provide limits on the fraction of an incident current pulse that would be accelerated by the existing accelerator. In this paper experimental data on this fraction are presented and the validity of the model developed previously is tested by comparing calculated and experimental data. Part of the experimental data is used to fix the physical parameters in the model and then good agreement between the calculated results and the rest of the experimental data is obtained

  11. CALCULATION-EXPERIMENTAL METHOD OF RESEARCH IN A METALLIC CONDUCTOR WITH THE PULSE CURRENT OF ELECTRONIC WAVEPACKAGES AND DE BROGLIE ELECTRONIC HALF-WAVES

    Directory of Open Access Journals (Sweden)

    M. I. Baranov

    2016-12-01

    Full Text Available Purpose. Development of calculation-experimental method for a discovery and study of electronic wavepackages (EWP and of de Broglie electronic half-waves in a metallic conductor with the pulse axial-flow current of high density. Methodology. Theoretical bases of the electrical engineering, bases of quantum physics, electrophysics bases of technique of high voltage and large pulsecurrents, and also bases of technique of measuring of permanent and variable electric value. Results. On the basis of generalization of results of research of features of the longitudinal wave periodic distributing of negatively charged transmitters of electric current of conductivity in the thin round continuous zincked steel wire offered and approved in the conditions of high-voltage laboratory method for a discovery and direct determination in him of geometrical parameters of «hot» and «cold» longitudinal areas quantized periodic longitudinal EWP and accordingly the mediated determination of values of the quantized lengths formative their de Broglie electronic half-waves. It is shown that results of close quantum mechanical calculations of EWP and quantized lengths λenz/2 of longitudinal de Broglie half-waves for the probed wire long l0 well comport with the results of the executed high temperature experiments on the powerful high-voltage generator of homopolar large pulse current of millisecond duration. Originality. First calculation-experimental a way the important for the theory of electricity fact of existence is set in a round metallic explorer with the impulsive axial-flow current of the quantized coherent de Broglie electronic half-waves, amplitudes of which at the quantum number of n=1,3,9 correspond the middles of «hot» longitudinal areas of EWP. Calculation quantum mechanical correlation of type of λenz/2=l0/n got experimental confirmation, in obedience to which on length of l0 conductor the integer of quantized electronic half-waves is always laid

  12. Microstructure and Critical Current Density of YBa2Cu3O7-x + BaSnO3 Thick Films Grown with Pre-Mixed Pulsed Laser Ablation Target (Postprint)

    Science.gov (United States)

    2010-01-01

    AFRL-RZ-WP-TP-2012-0149 MICROSTRUCTURE AND CRITICAL CURRENT DENSITY OF YBa2Cu3O7-x + BaSnO3 THICK FILMS GROWN WITH PRE-MIXED PULSED LASER...CURRENT DENSITY OF YBa2Cu3O7-x + BaSnO3 THICK FILMS GROWN WITH PRE-MIXED PULSED LASER ABLATION TARGET (POSTPRINT) 5a. CONTRACT NUMBER In-house 5b...YBa2Cu3O7-x (YBCO) + BaSnO3 (BSO) thin films with BSO nanocolumns have been shown to have improved critical current density (Jc) in applied magnetic fields

  13. Development of long-pulse heating & current drive actuators & operational techniques compatible with a high-Z divertor & first wall

    Energy Technology Data Exchange (ETDEWEB)

    Tynan, George [Univ. of California, San Diego, CA (United States)

    2018-01-09

    This was a collaboration between UCSD and MIT to study the effective application of ion-cyclotron heating (ICRH) on the EAST tokamak, located in China. The original goal was for UCSD to develop a diagnostic that would allow measurement of the steady state, or DC, convection pattern that develops on magnetic field lines that attach or connect to the ICRH antenna. This diagnostic would then be used to develop techniques and approaches that minimize or even eliminate such DC convection during application of strong ICRH heating. This was thought to then indicate reduction or elimination of parasitic losses of heating power, and thus be an indicator of effective RF heating. The original plan to use high speed digital gas-puff imaging (GPI) of the antenna-edge plasma region in EAST was ultimately unsuccessful due to limitations in machine and camera operations. We then decided to attempt the same experiment on the ALCATOR C-MOD tokamak at MIT which had a similar instrument already installed. This effort was ultimately successful, and demonstrated that the underlying idea of using GPI as a diagnostic for ICRH antenna physics would, in fact, work. The two-dimensional velocity fields of the turbulent structures, which are advected by RF-induced E x B flows, are obtained via the time-delay estimation (TDE) techniques. Both the magnitude and radial extension of the radial electric field E-r were observed to increase with the toroidal magnetic field strength B and the ICRF power. The TDE estimations of RF-induced plasma potentials are consistent with previous results based on the probe measurements of poloidal phase velocity. The results suggest that effective ICRH heating with reduced impurity production is possible when the antenna/box system is designed so as to reduce the RF-induced image currents that flow in the grounded conducting antenna frame elements that surround the RF antenna current straps.

  14. A methodology to investigate the intrinsic effect of the pulsed electric current during the spark plasma sintering of electrically conductive powders

    Directory of Open Access Journals (Sweden)

    Antonio Mario Locci, Alberto Cincotti, Sara Todde, Roberto Orrù and Giacomo Cao

    2010-01-01

    Full Text Available A novel methodology is proposed for investigating the effect of the pulsed electric current during the spark plasma sintering (SPS of electrically conductive powders without potential misinterpretation of experimental results. First, ensemble configurations (geometry, size and material of the powder sample, die, plunger and spacers are identified where the electric current is forced to flow only through either the sample or the die, so that the sample is heated either through the Joule effect or by thermal conduction, respectively. These ensemble configurations are selected using a recently proposed mathematical model of an SPS apparatus, which, once suitably modified, makes it possible to carry out detailed electrical and thermal analysis. Next, SPS experiments are conducted using the ensemble configurations theoretically identified. Using aluminum powders as a case study, we find that the temporal profiles of sample shrinkage, which indicate densification behavior, as well as the final density of the sample are clearly different when the electric current flows only through the sample or through the die containing it, whereas the temperature cycle and mechanical load are the same in both cases.

  15. Depinning of the transverse domain wall trapped at magnetic impurities patterned in planar nanowires: Control of the wall motion using low-intensity and short-duration current pulses

    Science.gov (United States)

    Paixão, E. L. M.; Toscano, D.; Gomes, J. C. S.; Monteiro, M. G.; Sato, F.; Leonel, S. A.; Coura, P. Z.

    2018-04-01

    Understanding and controlling of domain wall motion in magnetic nanowires is extremely important for the development and production of many spintronic devices. It is well known that notches are able to pin domain walls, but their pinning potential strength are too strong and it demands high-intensity current pulses to achieve wall depinning in magnetic nanowires. However, traps of pinning can be also originated from magnetic impurities, consisting of located variations of the nanowire's magnetic properties, such as exchange stiffness constant, saturation magnetization, anisotropy constant, damping parameter, and so on. In this work, we have performed micromagnetic simulations to investigate the depinning mechanism of a transverse domain wall (TDW) trapped at an artificial magnetic defect using spin-polarized current pulses. In order to create pinning traps, a simplified magnetic impurity model, only based on a local reduction of the exchange stiffness constant, have been considered. In order to provide a background for experimental studies, we have varied the parameter related to the pinning potential strength of the magnetic impurity. By adjusting the pinning potential of magnetic impurities and choosing simultaneously a suitable current pulse, we have found that it is possible to obtain domain wall depinning by applying low-intensity and short-duration current pulses. Furthermore, it was considered a planar magnetic nanowire containing a linear distribution of equally-spaced magnetic impurities and we have demonstrated the position control of a single TDW by applying sequential current pulses; that means the wall movement from an impurity to another.

  16. 35 Volt, 180 Ampere Pulse Generator with Droop Control for Pulsing Xenon Arcs

    DEFF Research Database (Denmark)

    Hviid, T.; Nielsen, S. O.

    1972-01-01

    The pulse generator described works as a combined switch and series current regulator and allows the shape of the current pulse to be adjusted at each optical wavelength to produce a flat pulse of monochromatic light....

  17. Preparation and Characterization of Apatitic Biphasic Calcium Phosphate

    International Nuclear Information System (INIS)

    Thin Thin Nwe; Kyaw Naing; Khin Mar Tun; Nyunt Wynn

    2005-09-01

    The apatitic biphasic calcium phosphate (ABcp) consisting of hydroxyapatite (HA) and -tricalcium phosphate ( -Tcp) has been prepared by precipitation technique using slaked lime and orthophosphoric acid. The X-ray diffraction analysis of the product I (hydroxyapatite) revealed that ABcp was partially crystalline state. However, on heating at 800 C for 8 hrs, XRD pattern indicated a perfectly crystalline form of ABcp. This observation was supported by FT-IR measurement. The change in morphology regarding in the functional nature was infered by the shift in the FT-IR frequency. The optimization of the apatitic biphasic calcium phosphate was done by the variation of disodium hydrogen phosphate concentration, setting time, hardening time as well as compressive strength. The perpared cement may be used as an artificial substitution bone

  18. Biphasic magnetic nanoparticles-nanovesicle hybrids for chemotherapy and self-controlled hyperthermia.

    Science.gov (United States)

    Gogoi, Manashjit; Sarma, Haladhar D; Bahadur, Dhirendra; Banerjee, Rinti

    2014-05-01

    The aim was to develop magnetic nanovesicles for chemotherapy and self-controlled hyperthermia that prevent overheating of tissues. Magnetic nanovesicles containing paclitaxel and a dextran-coated biphasic suspension of La0.75Sr0.25MnO3 and Fe3O4 nanoparticles (magnetic nanoparticles) were developed. Encapsulation efficiencies of magnetic nanoparticles and paclitaxel were 67 ± 5 and 83 ± 3%, respectively. Sequential release performed at 37°C for 1 h followed by 44°C for another 1 h (as expected for intratumoral injection), showed a cumulative release of 6.6% (109.6 µg), which was above the IC50 of the drug. In an alternating current magnetic field, the temperature remained controlled at 44°C and a synergistic cytotoxicity of paclitaxel and hyperthermia was observed in MCF-7 cells. Magnetic nanovesicles containing biphasic suspensions La0.75Sr0.25MnO3 and Fe3O4 nanoparticles encapsulating paclitaxel have potential for combined self-controlled hyperthermia and chemotherapy.

  19. Actinide recovery using aqueous biphasic extraction: Initial developmental studies

    International Nuclear Information System (INIS)

    Chaiko, D.J.; Mensah-Biney, R.; Mertz, C.J.; Rollins, A.N.

    1992-08-01

    Aqueous biphasic extraction systems are being developed to treat radioactive wastes. The separation technique involves the selective partitioning of either solutes or colloid-size particles between two scible aqueous phases. Wet grinding of plutonium residues to an average particle size of one micron will be used to liberate the plutonium from the bulk of the particle matrix. The goal is to produce a plutonium concentrate that will integrate with existing and developing chemical recovery processes. Ideally, the process would produce a nonTRU waste stream. Coupling physical beneficiation with chemical processing will result in a substantial reduction in the volume of mixed wastes generated from dissolution recovery processes. As part of this program, we will also explore applications of aqueous biphasic extraction that include the separation and recovery of dissolved species such as metal ions and water-soluble organics. The expertise and data generated in this work will form the basis for developing more cost-effective processes for handling waste streams from environmental restoration and waste management activities within the DOE community. This report summarizes the experimental results obtained during the first year of this effort. Experimental efforts were focused on elucidating the surface and solution chemistry variables which govern partitioning behavior of plutonium and silica in aqueous biphasic extraction systems. Additional efforts were directed toward the development of wet grinding methods for producing ultrafine particles with diameters of one micron or less

  20. Actinide recovery using aqueous biphasic extraction: Initial developmental studies

    Energy Technology Data Exchange (ETDEWEB)

    Chaiko, D.J.; Mensah-Biney, R.; Mertz, C.J.; Rollins, A.N.

    1992-08-01

    Aqueous biphasic extraction systems are being developed to treat radioactive wastes. The separation technique involves the selective partitioning of either solutes or colloid-size particles between two scible aqueous phases. Wet grinding of plutonium residues to an average particle size of one micron will be used to liberate the plutonium from the bulk of the particle matrix. The goal is to produce a plutonium concentrate that will integrate with existing and developing chemical recovery processes. Ideally, the process would produce a nonTRU waste stream. Coupling physical beneficiation with chemical processing will result in a substantial reduction in the volume of mixed wastes generated from dissolution recovery processes. As part of this program, we will also explore applications of aqueous biphasic extraction that include the separation and recovery of dissolved species such as metal ions and water-soluble organics. The expertise and data generated in this work will form the basis for developing more cost-effective processes for handling waste streams from environmental restoration and waste management activities within the DOE community. This report summarizes the experimental results obtained during the first year of this effort. Experimental efforts were focused on elucidating the surface and solution chemistry variables which govern partitioning behavior of plutonium and silica in aqueous biphasic extraction systems. Additional efforts were directed toward the development of wet grinding methods for producing ultrafine particles with diameters of one micron or less.

  1. Suppression of dark current radiation in step-and-shoot intensity modulated radiation therapy by the initial pulse-forming network

    International Nuclear Information System (INIS)

    Cheng, C.-W.; Das, Indra J.; Ndlovu, Alois M.

    2002-01-01

    The effect of the initial pulse forming network (IPFN) on the suppression of dark current is investigated for a Siemens Primus accelerator. The dark current produces a spurious radiation, which is referred to as dark current radiation (DCR) in this study. In the step-and-shoot delivery of an intensity modulated radiation therapy (IMRT), the DCR could be of some concern for whole body dose along with leakage radiation through collimator jaws or multileaf collimator. By adjusting the IPFN-to-PFN ratio to >0.8, the DCR can be measured with an ion chamber during the 'PAUSE' state of the accelerator in the IMRT mode. For 15 MV x rays, the magnitude of the DCR is approximately equal to 0.7% of the dose at d max for a 10x10 cm 2 field. The DCR has a similar central axis depth dose as a 15 MV beam as determined from a water phantom scan. When the IPFN-to-PFN ratio is lowered to <0.8, no DCR is detected. For low energy x rays (6 MV), no DCR is detected regardless of the IPFN-to-PFN ratio. Although the DCR is studied only for the Siemens Primus model accelerator, the same precaution applies to other models of modern accelerators from other vendors. Due to the large number of field segments used in a step-and-shoot IMRT, it is imperative therefore, that dark current evaluation be part of machine commissioning and annual calibration for high-energy photon beams. Should DCR be detected, the medical physicist should work with a service engineer to rectify the problem. In view of DCR and whole body dose, low-energy photon beams are advisable for IMRT

  2. Comparative degradation of ZnO- and SnO{sub 2}-based polycrystalline non-ohmic devices by current pulse stress

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, M A; Bueno, P R; Longo, E; Varela, J A [Instituto de Quimica, Universidade Estadual Paulista, UNESP, CEP. 14800-900, Araraquara, SP (Brazil); Bassi, W [Instituto de Eletrotecnica e Energia, Universidade de Sao Paulo, USP, 05508-010, Sao Paulo, SP, Brasil (Brazil)], E-mail: margbrasil@yahoo.com

    2008-06-21

    The degradation behaviour of SnO{sub 2}-based varistors (SCNCr) due to current pulses (8/20 {mu}s) is reported here for the first time in comparison with the ZnO-based commercial varistors (ZnO). Puncturing and/or cracking failures were observed in ZnO-based varistors possessing inferior thermo-mechanical properties in comparison with that found in a SCNCr system free of failures. Both systems presented electric degradation related to the increase in the leakage current and decrease in the electric breakdown field, non-linear coefficient and average value of the potential barrier height. However, it was found that a more severe degradation occurred in the ZnO-based varistors concerning their non-ohmic behaviour, while in the SCNCr system, a strong non-ohmic behaviour remained after the degradation. These results indicate that the degradation in the metal oxide varistors is controlled by a defect diffusion process whose rate depends on the mobility, the concentration of meta-stable defects and the amount of electrically active interfaces. The improved behaviour of the SCNCr system is then inferred to be associated with the higher amount of electrically active interfaces (85%) and to a higher energy necessary to activate the diffusion of the specific defects. (fast track communication)

  3. Low-tilt monophasic and biphasic waveforms compared with standard biphasic waveforms in the transvenous defibrillation of ventricular fibrillation.

    Science.gov (United States)

    Bennett, Johan R; Darragh, Karen M; Walsh, Simon J; Allen, Desmond J; Scott, Michael; Stevenson, Michael; Adgey, Jennifer A A; Anderson, John M C J; Manoharan, Ganesh

    2014-03-01

    Commercially available implantable defibrillators utilize a high-tilt waveform. Studies in atrial fibrillation and transthoracic defibrillation of ventricular fibrillation (VF) have shown improved defibrillation efficacy using low-tilt (LT) waveforms. We investigated the feasibility, efficacy, and safety of a LT waveform in the transvenous defibrillation of VF and hypothesized that it would be more efficacious than standard tilted biphasic (STB) waveforms. The investigation was performed in four phases in a porcine model: an efficacy study of LT monophasic waveforms (n = 9), an efficacy study of LT biphasic waveforms (n = 9), a comparison study between the most successful LT waveforms and clinically available STB waveforms (n = 15), and a safety study (n = 9). A total of 1,056 shocks were delivered (phase 1: 288, phase 2: 288, phase 3: 480). The LT biphasic 8/4-ms waveform was significantly more likely to successfully defibrillate than the LT monophasic and STB waveforms with an odds ratio of 122.3 (95% confidence interval: 32.5, 460.2, P defibrillation threshold (E50) for the LT 8/4-ms waveform was 12.7 J compared to 43.5 J and 45.5 J for STB waveforms 6/6 ms and 8/4 ms, respectively, and 47.7 J for LT 12-ms waveform. The LT 8/4-ms waveform had no lasting detrimental effect on cardiac function, and any transient hemodynamical or biochemical changes observed were comparable to those observed with STB waveforms. LT waveforms are effective and appear safe in transvenous defibrillation in a porcine model of VF. The LT biphasic 8/4-ms waveform is more efficacious than conventional waveforms. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  4. Improvement of the yield of highly charged ions by a gas-pulsing technique and the current status of the NIRS Penning source

    International Nuclear Information System (INIS)

    Miyata, Tomohiro; Miyoshi, Tomohiro; Sakuma, Tetsuya; Yamamoto, Mitsugu; Kitagawa, Atsushi; Muramatsu, Masayuki; Sato, Yukio

    2004-01-01

    The yields of highly charged ions have been improved by using a gas-pulsing technique in the pulsed Penning-ionized-gauge ion source (PIGIS) in the heavy-ion medical accelerator in Chiba. So far, this pulsed PIGIS has been operated under a low-duty factor (10 -2 -10 -3 ), in which the gas flow is not being pulsed. A solenoid-type gas valve, having a simple structure compared to the piezo-electric type, was attached to the outside of the PIGIS chamber in order to control the gas flow into the PIGIS chimney. Beam tests for Ne with gas pulsing showed that the pressure response time should actually be a few tens ms, and the intensity of Ne 6+ was increased by ten times, from 20 to 200 eμA. The gas pulsing also improved the average vacuum in the low energy beam transport (LEBT) line by a factor of 4. When producing H 2 + , H 3 + , and He 1+ by PIGIS with gas pulsing, the beam loss of highly charged ions from electron cyclotron resonance ion sources in the LEBT was reduced to be negligible; meanwhile, it was around 30% without gas pulsing. This paper describes the gas-pulsing technique and the preliminary results, as well as some recent developments in the NIRS-PIGIS

  5. Hall voltage drives pulsing counter-currents of the sliding charge density wave and of quantized normal carriers at self-filled Landau levels

    Science.gov (United States)

    Orlov, Andrey P.; Sinchenko, Aleksander A.; Monceau, Pierre; Brazovskii, Serguei; Latyshev, Yuri I.

    2017-11-01

    Remnant pockets of carriers left over after formation of a charge density wave (CDW) were brought, by virtue of transverse electric and magnetic fields, to a current-carrying state at quantized Landau Levels. The generated Hall voltage polarizes and puts to sliding the flexible CDW background. The screening from the CDW allows for a so strong redistribution of normal electrons density under the action of the Lorentz force alone, that an integer filling of the lowest Landau level might be reached at one edge at the expense of the full depletion at another edge of the Hall bar. With the Hall field exceeding the sliding threshold, the regime of exactly compensated collective and normal counter-currents develops in the open-circuit direction across the bar. The annihilation of the two currents proceeds via a regular sequence of phase slips which are the space-time vortices of the CDW phase around the enforced amplitude nodes. The resulting spontaneous generation of coherent high ( GHz) frequency signals was detected by observations of multiple Shapiro steps. This picture results from studies of micron-sized Hall bars in crystals of NbSe3 prepared by means of focused ion beams. The interpretation is confirmed and illustrated by a numerical solution of the derived equations. The depinning pulse propagates from edges to the bulk and the sliding sets in, accompanied by the generation of periodic phase slips near the Hall bar edge where the CDW phase is advanced in steps of 2π at expense of the CDW amplitude passing through zero.

  6. Pulse Generator

    Science.gov (United States)

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  7. Monophasic Pulsed 200-μA Current Promotes Galvanotaxis With Polarization of Actin Filament and Integrin α2β1 in Human Dermal Fibroblasts.

    Science.gov (United States)

    Uemura, Mikiko; Maeshige, Noriaki; Koga, Yuka; Ishikawa-Aoyama, Michiko; Miyoshi, Makoto; Sugimoto, Masaharu; Terashi, Hiroto; Usami, Makoto

    2016-01-01

    The monophasic pulsed microcurrent is used to promote wound healing, and galvanotaxis regulation has been reported as one of the active mechanisms in the promotion of tissue repair with monophasic pulsed microcurrent. However, the optimum monophasic pulsed microcurrent parameters and intracellular changes caused by the monophasic pulsed microcurrent have not been elucidated in human dermal fibroblasts. The purpose of this study was to investigate the optimum intensity for promoting galvanotaxis and the effects of electrical stimulation on integrin α2β1 and actin filaments in human dermal fibroblasts. Human dermal fibroblasts were treated with the monophasic pulsed microcurrent of 0, 100, 200, or 300 μA for 8 hours, and cell migration and cell viability were measured 24 hours after starting monophasic pulsed microcurrent stimulation. Polarization of integrin α2β1 and lamellipodia formation were detected by immunofluorescent staining 10 minutes after starting monophasic pulsed microcurrent stimulation. The migration toward the cathode was significantly higher in the cells treated with the 200-μA monophasic pulsed microcurrent than in the controls (P microcurrent did not alter the migration ratio. The electrostimulus of 200 μA also promoted integrin α2β1 polarization and lamellipodia formation at the cathode edge (P microcurrent intensity to promote migration toward the cathode, and this intensity could regulate polarization of migration-related intracellular factors in human dermal fibroblasts.

  8. Development of Long-Pulse Heating and Current Drive Actuators and Operational Techniques Compatible with a High-Z Divertor and First Wall

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Guiding [Univ. of California, Los Angeles, CA (United States)

    2017-11-02

    Accurate measurement of the edge electron density profile is essential to optimizing antenna coupling and assessment of impurity contamination in studying long-pulse plasma heating and current drive in fusion devices. Measurement of the edge density profile has been demonstrated on the US fusion devices such as C-Mod, DIII-D, and TFTR amongst many devices, and has been used for RF loading and impurity modeling calculations for many years. University of Science and Technology of China (USTC) has recently installed a density profile reflectometer system on the EAST fusion device at the Institute of Plasma Physics, Chinese Academy of Sciences in China based on the University of California Los Angeles (UCLA)-designed reflectometer system on the DIII-D fusion device at General Atomics Company in San Diego, California. UCLA has been working with USTC to optimize the existing microwave antenna, waveguide system, microwave electronics, and data analysis to produce reliable edge density profiles. During the past budget year, progress has been made in all three major areas: effort to achieve reliable system operations under various EAST operational conditions, effort to optimize system performance, and effort to provide quality density profiles into EAST’s database routinely.

  9. Mechanical properties of simultaneously synthesized and consolidated carbon nanofiber (CNF)-dispersed SiC composites by pulsed electric-current pressure sintering

    International Nuclear Information System (INIS)

    Hirota, Ken; Hara, Hiroaki; Kato, Masaki

    2007-01-01

    Carbon nanofiber (CNF) dispersed β-SiC composites with the addition of 0.2 mass% boron and 2.0 mass% carbon as sintering aids have been synthesized and consolidated simultaneously from mixtures of Si, amorphous C and B powders and CNF by pulsed electric-current pressure sintering (PECPS). Synthesis and consolidation process, which were observed from their expansion and shrinkage curves during PECPS, have been examined using X-ray diffraction and scanning electron microscopy for the powder compacts. CNF/SiC composites sintered at 1800 deg. C for 10 min under 40 MPa in a vacuum have ∼96.0% of theoretical density and homogeneous structures consisting of ∼4.0 μm grains. A 10 vol% CNF/SiC composite exhibited excellent mechanical properties: a bending strength of ∼720 MPa, a Vickers hardness of ∼26.0 GPa, and a fracture toughness of ∼5.5 MPa m 1/2 . High-temperature bending strength of ∼890 MPa at 1200 deg. C in air was attained with the same nanocomposites

  10. Simultaneous synthesis and consolidation of chromium carbides (Cr3C2, Cr7C3 and Cr23C6) by pulsed electric-current pressure sintering

    International Nuclear Information System (INIS)

    Hirota, Ken; Mitani, Kenichi; Yoshinaka, Masaru; Yamaguchi, Osamu

    2005-01-01

    Chromium carbides (Cr 3 C 2 , Cr 7 C 3 and Cr 23 C 6 ) have been synthesized and consolidated simultaneously from mixtures of Cr and amorphous carbon powders by pulsed electric-current pressure sintering (PECPS). Dense ceramics thus obtained were composed of chromium carbides with a small amount of Cr 2 O 3 , which originates from a trace amount of oxygen adsorbed on the as-received starting Cr powder. Synthesis and consolidation processes, which were observed from their shrinkage curves during PECPS, have been examined using X-ray diffraction (XRD) and scanning electron microscopy for the powder compacts. Cr 3 C 2 ceramics sintered at 1300 deg. C for 10 min under 30 MPa have a 98.9% of theoretical density and fine structures with a 3.6 μm grain size. They exhibit excellent mechanical properties: a bending strength σ b of 690 MPa, a Vickers hardness H v of 18.9 GPa and a fracture toughness K IC of 7.1 MPa m 1/2

  11. Comparative Study on the Grain Refinement of Al-Si Alloy Solidified under the Impact of Pulsed Electric Current and Travelling Magnetic Field

    Directory of Open Access Journals (Sweden)

    Yunhu Zhang

    2016-07-01

    Full Text Available It is high of commercial importance to generate the grain refinement in alloys during solidification by means of electromagnetic fields. Two typical patterns of electromagnetic fields, pulsed electric currents (ECP and traveling magnetic field (TMF, are frequently employed to produce the finer equiaxed grains in solidifying alloys. Various mechanisms were proposed to understand the grain refinement in alloys caused by ECP and TMF. In this paper, a comparative study is carried out in the same solidification regime to investigate the grain refinement of Al-7 wt. %Si alloy driven by ECP and TMF. Experimental results show that the application of ECP or TMF can cause the same grain refinement occurrence period, during which the refinement of primary Al continuously occurs. In addition, the related grain refinement mechanisms are reviewed and discussed, which shows the most likely one caused by ECP and TMF is the promoted dendrite fragmentation as the result of the ECP-induced or TMF-induced forced flow. It suggests that the same grain refinement process in alloys is provoked when ECP and TMF are applied in the same solidification regime, respectively.

  12. A Gradient-Field Pulsed Eddy Current Probe for Evaluation of Hidden Material Degradation in Conductive Structures Based on Lift-Off Invariance.

    Science.gov (United States)

    Li, Yong; Jing, Haoqing; Zainal Abidin, Ilham Mukriz; Yan, Bei

    2017-04-25

    Coated conductive structures are widely adopted in such engineering fields as aerospace, nuclear energy, etc. The hostile and corrosive environment leaves in-service coated conductive structures vulnerable to Hidden Material Degradation (HMD) occurring under the protection coating. It is highly demanded that HMD can be non-intrusively assessed using non-destructive evaluation techniques. In light of the advantages of Gradient-field Pulsed Eddy Current technique (GPEC) over other non-destructive evaluation methods in corrosion evaluation, in this paper the GPEC probe for quantitative evaluation of HMD is intensively investigated. Closed-form expressions of GPEC responses to HMD are formulated via analytical modeling. The Lift-off Invariance (LOI) in GPEC signals, which makes the HMD evaluation immune to the variation in thickness of the protection coating, is introduced and analyzed through simulations involving HMD with variable depths and conductivities. A fast inverse method employing magnitude and time of the LOI point in GPEC signals for simultaneously evaluating the conductivity and thickness of HMD region is proposed, and subsequently verified by finite element modeling and experiments. It has been found from the results that along with the proposed inverse method the GPEC probe is applicable to evaluation of HMD in coated conductive structures without much loss in accuracy.

  13. The quaternary lidocaine derivative, QX-314, exerts biphasic effects on transient receptor potential vanilloid subtype 1 channels in vitro

    DEFF Research Database (Denmark)

    Rivera-Acevedo, Ricardo E; Pless, Stephan Alexander; Ahern, Christopher A

    2011-01-01

    BACKGROUND: Transient receptor potential vanilloid subfamily member 1 (TRPV1) channels are important integrators of noxious stimuli with pronounced expression in nociceptive neurons. The experimental local anesthetic, QX-314, a quaternary (i.e., permanently charged) lidocaine derivative, recently...... concentrations (less than 1 mM), QX-314 potently inhibited capsaicin-evoked TRPV1 currents with an IC₅₀ of 8.0 ± 0.6 μM. CONCLUSIONS: The results of this study show that the quaternary lidocaine derivative QX-314 exerts biphasic effects on TRPV1 channels, inhibiting capsaicin-evoked TRPV1 currents at lower...

  14. Generic Model-Based Tailor-Made Design and Analysis of Biphasic Reaction Systems

    DEFF Research Database (Denmark)

    Anantpinijwatna, Amata

    systems have a broad range of application, such as the manufacture of petroleum based chemicals, pharmaceuticals, and agro-bio products. Major considerations in the design and analysis of biphasic reaction systems are physical and chemical equilibria, kinetic mechanisms, and reaction rates. The primary...... different organic solvents leading to an improved and innovative design of the system.......Biphasic reaction systems are composed of immiscible aqueous and organic liquid phases where reactants, products, and catalysts are partitioned. These biphasic conditions point to novel synthesis paths, higher yields, and faster reactions, as well as facilitate product separation. The biphasic...

  15. The role of pulse shape in motor cortex transcranial magnetic stimulation using full-sine stimuli

    DEFF Research Database (Denmark)

    Delvendahl, Igor; Gattinger, Norbert; Berger, Thomas

    2014-01-01

    A full-sine (biphasic) pulse waveform is most commonly used for repetitive transcranial magnetic stimulation (TMS), but little is known about how variations in duration or amplitude of distinct pulse segments influence the effectiveness of a single TMS pulse to elicit a corticomotor response. Using...... a novel TMS device, we systematically varied the configuration of full-sine pulses to assess the impact of configuration changes on resting motor threshold (RMT) as measure of stimulation effectiveness with single-pulse TMS of the non-dominant motor hand area (M1). In young healthy volunteers, we (i...

  16. Non-inductive current probe

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl

    1977-01-01

    The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is......The current probe described is a low-cost, shunt resistor for monitoring current pulses in e.g., pulsed lasers. Rise time is...

  17. A new kinetic biphasic approach applied to biodiesel process intensification

    Energy Technology Data Exchange (ETDEWEB)

    Russo, V.; Tesser, R.; Di Serio, M.; Santacesaria, E. [Naples Univ. (Italy). Dept. of Chemistry

    2012-07-01

    Many different papers have been published on the kinetics of the transesterification of vegetable oil with methanol, in the presence of alkaline catalysts to produce biodiesel. All the proposed approaches are based on the assumption of a pseudo-monophasic system. The consequence of these approaches is that some experimental aspects cannot be described. For the reaction performed in batch conditions, for example, the monophasic approach is not able to reproduce the different plateau obtained by using different amount of catalyst or the induction time observed at low stirring rates. Moreover, it has been observed by operating in continuous reactors that micromixing has a dramatic effect on the reaction rate. At this purpose, we have recently observed that is possible to obtain a complete conversion to biodiesel in less than 10 seconds of reaction time. This observation is confirmed also by other authors using different types of reactors like: static mixers, micro-reactors, oscillatory flow reactors, cavitational reactors, microwave reactors or centrifugal contactors. In this work we will show that a recently proposed biphasic kinetic approach is able to describe all the aspects before mentioned that cannot be described by the monophasic kinetic model. In particular, we will show that the biphasic kinetic model can describe both the induction time observed in the batch reactors, at low stirring rate, and the very high conversions obtainable in a micro-channel reactor. The adopted biphasic kinetic model is based on a reliable reaction mechanism that will be validated by the experimental evidences reported in this work. (orig.)

  18. The Streptococcus pneumoniae pilus-1 displays a biphasic expression pattern.

    Directory of Open Access Journals (Sweden)

    Gabriella De Angelis

    Full Text Available The Streptococcus pneumoniae pilus-1 is encoded by pilus islet 1 (PI-1, which has three clonal variants (clade I, II and III and is present in about 30% of clinical pneumococcal isolates. In vitro and in vivo assays have demonstrated that pilus-1 is involved in attachment to epithelial cells and virulence, as well as protection in mouse models of infection. Several reports suggest that pilus-1 expression is tightly regulated and involves the interplay of numerous genetic regulators, including the PI-1 positive regulator RlrA. In this report we provide evidence that pilus expression, when analyzed at the single-cell level in PI-1 positive strains, is biphasic. In fact, the strains present two phenotypically different sub-populations of bacteria, one that expresses the pilus, while the other does not. The proportions of these two phenotypes are variable among the strains tested and are not influenced by genotype, serotype, growth conditions, colony morphology or by the presence of antibodies directed toward the pilus components. Two sub-populations, enriched in pilus expressing or not expressing bacteria were obtained by means of colony selection and immuno-detection methods for five strains. PI-1 sequencing in the two sub-populations revealed the absence of mutations, thus indicating that the biphasic expression observed is not due to a genetic modification within PI-1. Microarray expression profile and western blot analyses on whole bacterial lysates performed comparing the two enriched sub-populations, revealed that pilus expression is regulated at the transcriptional level (on/off regulation, and that there are no other genes, in addition to those encoded by PI-1, concurrently regulated across the strains tested. Finally, we provide evidence that the over-expression of the RrlA positive regulator is sufficient to induce pilus expression in pilus-1 negative bacteria. Overall, the data presented here suggest that the observed biphasic pilus

  19. Osteoinduction of biphasic calcium phosphate scaffolds in a nude mouse model.

    Science.gov (United States)

    Miramond, T; Corre, P; Borget, P; Moreau, F; Guicheux, J; Daculsi, G; Weiss, P

    2014-10-01

    Bioceramics combined with isolated stem cells, or with total bone marrow, constitute the main strategies under consideration in the field of bone tissue engineering. In the present preclinical study, two biphasic calcium phosphate scaffolds currently on the market, MBCP® and MBCP+®, with different hydroxyapatite/β-tricalcium phosphate ratio, were implanted ectopically in a nude mouse model. These scaffolds were supplemented either with human mesenchymal stromal cells, or with human total bone marrow, or rat total bone marrow. Biomaterials alone were found to have potentially low, but non-zero, osteoinductive properties, while biomaterials associated with total bone marrow consistently improved osteoinduction in comparison with high concentrations of isolated human stromal cells. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. A new biphasic osteoinductive calcium composite material with a negative Zeta potential for bone augmentation

    Directory of Open Access Journals (Sweden)

    Maciejewski Oliver

    2009-06-01

    Full Text Available Abstract The aim of the present study was to analyze the osteogenic potential of a biphasic calcium composite material (BCC with a negative surface charge for maxillary sinus floor augmentation. In a 61 year old patient, the BCC material was used in a bilateral sinus floor augmentation procedure. Six months postoperative, a bone sample was taken from the augmented regions before two titanium implants were inserted at each side. We analyzed bone neoformation by histology, bone density by computed tomography, and measured the activity of voltage-activated calcium currents of osteoblasts and surface charge effects. Control orthopantomograms were carried out five months after implant insertion. The BCC was biocompatible and replaced by new mineralized bone after being resorbed completely. The material demonstrated a negative surface charge (negative Zeta potential which was found to be favorable for bone regeneration and osseointegration of dental implants.

  1. Spindle-cell squamous carcinoma of the esophagus: a tumor with biphasic morphology

    Energy Technology Data Exchange (ETDEWEB)

    Agha, F.P.; Keren, D.F.

    1985-09-01

    Spindle-cell squamous carcinoma of the esophagus is a rare malignant tumor. It is characterized by a large bulky mass in the middle third of the esophagus with a lobulated surface and local expansion of the esophagus. This lesion may be pedunculated and cause relatively little obstruction despite its bulk. The current view, based on ultrastructure and immunohistochemical evidence, has confirmed that the sarcomatous component of the squamous cell carcinoma originates from mesenchymal metaplasia of squamous cells. On the basis of this evidence and clinical behavior, it seems appropriate to consider carcinosarcoma and pseudosarcoma as equivalents and as variants of squamous cell carcinoma. Four patients with spindle-cell squamous carcinoma, an unusual subset of squamous carcinoma, are described, and the salient radiographic and pathologic features of this disorder's distinctive biphasic morphology are discussed.

  2. Enhancement and Angular Dependence of Transport Critical Current Density in Pulsed Laser Deposited YBa2Cu3O7-x+BaSnO3 Films in Applied Magnetic Fields (Postprint)

    Science.gov (United States)

    2007-09-25

    BaSnO3 FILMS IN APPLIED MAGNETIC FIELDS (POSTPRINT) C.V. Varanasi, J. Burke, and L. Brunke University of Dayton Research Institute H. Wang...SUBTITLE ENHANCEMENT AND ANGULAR DEPENDENCE OF TRANSPORT CRITICAL CURRENT DENSITY IN PULSED LASER DEPOSITED YBa2Cu3O7−x+ BaSnO3 FILMS IN APPLIED...nanoparticles of BaSnO3 (BSO) were processed using pulsed laser ablation of a special target made with dual phase sectors of YBCO and BSO. Transport critical

  3. Pulse power modulators - an overview

    International Nuclear Information System (INIS)

    Venkatramani, N.

    2006-01-01

    Pulse power modulators are electronic devices to provide, high voltage, high current, power bursts. Ideally, a modulator, with the means to shape and control the pulses, acts as a switch between a high voltage power supply and its load. This article gives an overview of the pulse power modulators: starting with the basics of pulse and modulation, it covers modulation topologies, different types of modulators, major subsystems and pulse measurement techniques. The various applications of pulse power modulators and the recent trends have been included at the end. (author)

  4. Biphasic Fluence-Response Curves for Phytochrome-Mediated Kalanchoë Seed Germination 1

    Science.gov (United States)

    Rethy, Roger; Dedonder, Andrée; De Petter, Edwin; Van Wiemeersch, Luc; Fredericq, Henri; De Greef, Jan; Steyaert, Herman; Stevens, Hilde

    1987-01-01

    The fluence-response curves for the effect of two red pulses separated by 24 hours on the germination of Kalanchoe blossfeldiana Poelln. cv Vesuv seeds, incubated on gibberellic acid (GA3) are biphasic for suboptimal concentrations. The response in the low fluence range corresponds with a classical red/far-red reversible phytochrome mediated reaction. GA3 induces an additional response in the very low fluence range, which is also phytochrome mediated. The sensitivity to phytochrome-far-red absorbing form (Pfr), however, is increased about 20,000-fold, so that even far-red fluences become saturating. Both in the very low and low fluence response range, the maximal responses induced by saturating fluences are modulated by the GA3 concentration. GA3 having no direct influence on the phytochrome phototransformations, alters the Pfr requirement and determines the responding seed population fraction in the very low and low fluence range. The effet of GA3 appears to be on the transduction chain of the phytochrome signal. PMID:16665187

  5. Low temperature pulsed direct current magnetron sputtering technique for single phase β-In2S3 buffer layers for solar cell applications

    Science.gov (United States)

    Karthikeyan, Sreejith; Hill, Arthur E.; Pilkington, Richard D.

    2017-10-01

    This work explores the possibilities of using the pulsed direct current (dc) magnetron sputtering (PDCMS) process to deposit an alternative to the cadmium sulphide buffer layer in copper indium gallium diselenide - based solar cells. The main problems with the CdS layer are its toxic nature and its deposition using a chemical bath technique. These factors make it difficult to incorporate into in-line production and significant effort has been expended to find a suitable alternative buffer layer with in-line manufacturing capability. Towards this aim, the material properties of an In2S3 film, sputtered from a powder target, have been investigated. Films were deposited at different substrate temperatures ranging from ;no additional substrate heating; to 250 °C. The deposition of a single phase β-In2S3 without substrate heating/annealing has not previously been reported. The films deposited by the ion-enhanced PdcMS technique without any additional heating were found to be single phase. The grain size increased with increase in substrate temperature. However, this led to a decrease in the sulphur content; as a result the band gap decreased. For solar cell applications, the CdS buffer layer (optical band gap ∼2.4 eV) needs to be replaced with a material which has a band gap wider than 2.4 eV for improved performance and reduction of absorption loss in the blue wavelength region. Ideally the band gap should be between 2.6 and 3.0 eV. Our PdcMS room temperature deposited In2S3 had a measured band gap of 2.77 eV.

  6. Development and Characterization of Biphasic Hydroxyapatite/β-TCP Cements.

    Science.gov (United States)

    Gallinetti, Sara; Canal, Cristina; Ginebra, Maria-Pau; Ferreira, J

    2014-04-01

    Biphasic calcium phosphate bioceramics composed of hydroxyapatite (HA) and β-tricalcium phosphate (β-TCP) have relevant properties as synthetic bone grafts, such as tunable resorption, bioactivity, and intrinsic osteoinduction. However, they have some limitations associated to their condition of high-temperature ceramics. In this work self-setting Biphasic Calcium Phosphate Cements (BCPCs) with different HA/β-TCP ratios were obtained from self-setting α-TCP/β-TCP pastes. The strategy used allowed synthesizing BCPCs with modulated composition, compressive strength, and specific surface area. Due to its higher solubility, α-TCP was fully hydrolyzed to a calcium-deficient HA (CDHA), whereas β-TCP remained unreacted and completely embedded in the CDHA matrix. Increasing amounts of the non-reacting β-TCP phase resulted in a linear decrease of the compressive strength, in association to the decreasing amount of precipitated HA crystals, which are responsible for the mechanical consolidation of apatitic cements. Ca 2+ release and degradation in acidic medium was similar in all the BCPCs within the timeframe studied, although differences might be expected in longer term studies once β-TCP, the more soluble phase was exposed to the surrounding media.

  7. Terahertz pulse driven Josephson junctions

    Energy Technology Data Exchange (ETDEWEB)

    Camerlingo, Carlo, E-mail: c.camerlingo@cib.na.cnr.it [CNR - Consiglio Nazionale delle Ricerche, Istituto di Cibernetica ' E. Caianiello' , Via Campi Flegrei 34, I-80078 Pozzuoli (Italy)

    2011-09-15

    Theoretical model of the ac Josephson effect in pulsed current driven junctions. Evaluation of the voltage response of a THz pulsed radiation driven Josephson junction. The pulsed current bias induces steps in the junction I/V characteristics for voltages depending on the pulse rate. Working principles of a fast response detector for THz pulsed radiation. The voltage response of a Josephson junction to a pulsed terahertz current is evaluated in the limit of a negligible junction capacitance (overdamped limit). The time-dependent superconductor phase difference across the junction is calculated in the framework of the standard resistive shunted junction model by using a perturbative method. The pulsed current bias affects the time average value of the voltage across the junction and current steps are induced in the current-voltage characteristics for voltage values depending on the pulse repetition rate. The current step height is proportional to the square of the pulse time width ({tau}) to the period (T) ratio. A fast response detector for pulsed Terahertz radiation is proposed, with an expected responsivity of the order of 0.1 V/W and an equivalent noise power of about 3 x 10{sup -10} W/Hz{sup 1/2}.

  8. Bi-phasic hitting with constraints on impact velocity and temporal precision

    NARCIS (Netherlands)

    Caljouw, S.R.; van der Kamp, J.; Savelsbergh, G.J.P.

    2005-01-01

    The aim of the experiment was to investigate how bi-phasic hitting movements are organized to comply with both impact and temporal precision constraints. 'Bi-phasic' refers to a sequential movement with a preparatory movement away from the interception location followed by a strike phase. The

  9. Biphasic Catalysis with Disaccharide Phosphorylases: Chemoenzymatic Synthesis of alpha-D-Glucosides Using Sucrose Phosphorylase

    Czech Academy of Sciences Publication Activity Database

    De Winter, K.; Desmet, T.; Devlamynck, T.; Van Renterghem, L.; Verhaeghe, T.; Pelantová, Helena; Křen, Vladimír; Soetaert, W.

    2014-01-01

    Roč. 18, č. 6 (2014), s. 781-787 ISSN 1083-6160 R&D Projects: GA MŠk(CZ) 7E11011 Institutional support: RVO:61388971 Keywords : biphasic systems * pyrogallol * biphasic catalysis Subject RIV: CE - Biochemistry Impact factor: 2.528, year: 2014

  10. IAE pulsed electrostatic accelerator

    International Nuclear Information System (INIS)

    Afanas'ev, V.P.; Ganzhelyuk, M.L.; Kozlov, L.D.; Koltypin, E.A.; Molchanov, Yu.D.; Otroshchenko, G.A.; Yan'kov, G.B.

    1976-01-01

    The modernized pulse electrostatic accelerator using the klystron ion grouping and the beam interruption system prior to acceleration is described. The accelerator is modernized in order to improve parameters of a current pulse and to decrease the background in the measurement room. The ion beam of needed dimensions is obtained with the help of a high-frequency source and a beam grouping and deflection system. The general view of the beam grouping and deflection system is shown. The ion beam forming process is considered in detail. The modernized electrostatic accelerator permits to obtain a pulse current with a pulse length of 1.5 ns and an amplitude of 1.5 - 2 μA. With the repetition frequency of 2 MHz, the average target current is about 6 μA

  11. New technetium-99m generator technologies utilizing polyethylene glycol-based aqueous biphasic systems

    Energy Technology Data Exchange (ETDEWEB)

    Rogers, R.D.; Bond, A.H.; Zhang, Jianhua [Northern Illinois Univ., De Kalb, IL (United States). Dept. of Chemistry; Horwitz, P. [Argonne National Lab., IL (United States)

    1995-12-31

    Two new schemes for TcO{sub 4}{sup {minus}}/MoO{sub 4}{sup 2{minus}} separations from OH{sup {minus}} and MoO{sub 4}{sup 2{minus}} media using polyethylene glycol (PEG)-based aqueous biphasic systems (ABS) have been developed. The two most important salt solutions in current {sup 99m}Tc-generator technologies, OH{sup {minus}} and MoO{sub 4}{sup 2{minus}}, also salt out PEG to form ABS. In liquid/liquid PEG- ABS, pertechnetate can be separated from molybdate with separation factors as high as 10,000. Stripping is accomplished by reduction of the TcO{sub 4}{sup {minus}} and back extraction into a salt solution. the strip solution can be the salt of an imaging agent (e.g., Na{sub 4}HEDPA) and thus may, under the appropriate conditions, be injected directly into the human body. {sup 99m}TcO{sub 4}{sup {minus}} can also be concentrated from a dilute load solution of {sup 99}MoO{sub 4}{sup 2{minus}} in NaOH using an aqueous biphasic extraction chromatographic technique (ABEC). A rinse with K{sub 2}CO{sub 3} assures that all {sup 99}MoO{sub 4}{sup 2{minus}} is removed from the column and this is confirmed by a rapid drop in {sup 99}Mo activity by the fourth free column volume (fcv) of rinse. The {sup 99m}TcO{sub 4}{sup {minus}} is then eluted with water. This chromatographic separation affords 94% of the {sup 99m}TcO{sub 4}{sup {minus}} activity in 5 fcv, with the y spectrum showing less than 2 {times} 10{sup {minus}4} of the original {sup 99}Mo activity.

  12. Sawtooth first phase biphasic defibrillation waveform: a comparison with standard waveform in clinical devices.

    Science.gov (United States)

    Yamanouchi, Y; Brewer, J E; Mowrey, K A; Kroll, M W; Donohoo, A M; Wilkoff, B L; Tchou, P J

    1997-05-01

    A major limitation in a conventional truncated exponential waveform is the rapid drop in current that results in short duration of high current or longer duration with a lower average current. We hypothesized that increasing the first phase average current by boosting the decaying waveform prior to phase reversal may improve defibrillation efficacy. To better simulate a "rectangular" waveform during the first phase, a "sawtooth" defibrillation waveform was constructed using "parallel-series" switching of capacitances (each 30 microF) during the first phase. This permitted a boost in the voltage late in the first phase. This sawtooth biphasic waveform (sawtooth) was compared to two clinical waveforms: a 135-microF capacitance (control-1) and a 90-microF capacitance (control-2) waveform. Defibrillation threshold (DFT) parameters were evaluated in 13 anesthetized pig models using a system consisting of a transvenous right ventricular apex lead (anode) and a left pectoral "hot can" electrode (cathode) system. DFT was determined by a "down-up down-up" protocol. The stored energy for sawtooth, control-1, and control-2 was 10.5 +/- 2.8 J, 12.3 +/- 3.7 J*, and 12.2 +/- 2.8 J*, respectively (*P series" switching system of smaller capacitors can improve defibrillation efficacy. A higher average current in the first phase generated by such a waveform may contribute to more efficient defibrillation by facilitating myocyte capture.

  13. A tripolar current-steering stimulator ASIC for field shaping in deep brain stimulation.

    Science.gov (United States)

    Valente, Virgilio; Demosthenous, Andreas; Bayford, Richard

    2012-06-01

    A significant problem with clinical deep brain stimulation (DBS) is the high variability of its efficacy and the frequency of side effects, related to the spreading of current beyond the anatomical target area. This is the result of the lack of control that current DBS systems offer on the shaping of the electric potential distribution around the electrode. This paper presents a stimulator ASIC with a tripolar current-steering output stage, aiming at achieving more selectivity and field shaping than current DBS systems. The ASIC was fabricated in a 0.35-μ m CMOS technology occupying a core area of 0.71 mm(2). It consists of three current sourcing/sinking channels. It is capable of generating square and exponential-decay biphasic current pulses with five different time constants up to 28 ms and delivering up to 1.85 mA of cathodic current, in steps of 4 μA, from a 12 V power supply. Field shaping was validated by mapping the potential distribution when injecting current pulses through a multicontact DBS electrode in saline.

  14. Silver-Collagen Dressing and High-voltage, Pulsed-current Therapy for the Treatment of Chronic Full-thickness Wounds: A Case Series.

    Science.gov (United States)

    Zhou, Kehua; Krug, Kenneth; Stachura, John; Niewczyk, Paulette; Ross, Michael; Tutuska, Justine; Ford, Gregory

    2016-03-01

    Research suggests high-voltage, pulsed-current electric therapy (HVPC) is safe and effective for treating chronic wounds, and some data suggest silver- and collagen-based dressings may facilitate healing. A combination therapy utilizing both HVPC and silver-collagen dressing may present clinical advantages. To explore the effect of the combined therapy for chronic full-thickness wounds, a prospective, consecutive case series study was conducted. All participants were adults with wounds of at least 6 weeks' duration. After obtaining informed consent, patient and wound characteristics were obtained, wounds were assessed and measured, and patients received 2 to 3 HVPC treatments per week followed by application of the silver- and collagen-based dressing for a period of 2 weeks. Data were analyzed descriptively, and changes in wound size and volume from baseline were analyzed using Wilcoxon Signed Rank Test. The dressings were saturated with normal saline, used simultaneously during the 45-minute HVPC treatment, and left on top of the wound after treatment. The HVPC electro pads (stainless steel electrodes with a sponge interface) also were moistened with normal saline and the cathode placed on top of the wound. If the patient had more than 1 wound on the same leg, the anode was placed on the additional wound (otherwise over the intact skin nearby). Secondary dressings (eg, foam and/ or gauze) were used as clinically appropriate, and a 4-layer compression wrap was used, if indicated, for patients with venous ulcers. Ten (10) patients (3 women, 7 men, 57.30 ± 9.70 years old with 14 wounds of 273.10 ± 292.03 days' duration before study) completed the study and were included in the final analyses. Average wound surface area decreased from 13.78 ± 21.35 cm(2) to 9.07 ± 16.81 cm(2) (42.52% ± 34.16% decrease, P = 0.002) and wound volume decreased from 3.39 ± 4.31 cm(3) to 1.28 ± 2.25 cm(3) (66.84% ± 25.07% decrease, P = 0.001). One (1) patient was discharged with

  15. Biphasic 201thallium scintgraphy after dipyridamole in mitral valve diseases

    International Nuclear Information System (INIS)

    Schmoliner, R.; Dudczak, R.; Kronik, G.; Moesslacher, H.; Kletter, K.; Frischauf, H.

    1980-01-01

    The results of biphasic 201 thallium scintigraphy after dipyridamole i.v. could neither prove nor exclude the presence of small focal lesions in the myocardium of 17 patients with mitral valve diseases. The frequent finding of a decrease in activity in the anterolateral myocardium is probably due to a relative increase in activity in the region of the inferior wall with superimposed areas of the papillary muscle and right ventricular myocardium. If the right ventricle is visualized in stress- or redistribution images, an increase in mean pulmonary artery pressure can be accepted. According to Cohen's criteria, a grade 2 or 3 virtually proves the existence of pulmonary hypertension, a grade 1 makes this finding rather probable. The possibility of pulmonary hypertension can not be excluded if the right ventricular myocardium is not visualized. (orig.) [de

  16. Pulse-width discriminators

    International Nuclear Information System (INIS)

    Budyashov, Yu.G.; Grebenyuk, V.M.; Zinov, V.G.

    1978-01-01

    A pulse duration discriminator is described which is intended for processing signals from multilayer scintillators. The basic elements of the scintillator are: an input gate, a current generator, an integrating capacitor, a Schmidt trigger and an anticoincidence circuit. The basic circuit of the discriminator and its time diagrams explaining its operating are given. The discriminator is based on microcircuits. Pulse duration discrimination threshold changes continuously from 20 to 100 ns, while its amplitude threshold changes within 20 to 100 mV. The temperature instability of discrimination thresholds (both in pulse width and in amplitude) is better than 0.1 per cent/deg C

  17. Foundations of pulsed power technology

    CERN Document Server

    Lehr, Janet

    2018-01-01

    Pulsed power technologies could be an answer to many cutting-edge applications. The challenge is in how to develop this high-power/high-energy technology to fit current market demands of low-energy consuming applications. This book provides a comprehensive look at pulsed power technology and shows how it can be improved upon for the world of today and tomorrow. Foundations of Pulsed Power Technology focuses on the design and construction of the building blocks as well as their optimum assembly for synergetic high performance of the overall pulsed power system. Filled with numerous design examples throughout, the book offers chapter coverage on various subjects such as: Marx generators and Marx-like circuits; pulse transformers; pulse-forming lines; closing switches; opening switches; multi-gigawatt to multi-terawatt systems; energy storage in capacitor banks; electrical breakdown in gases; electrical breakdown in solids, liquids and vacuum; pulsed voltage and current measurements; electromagnetic interferen...

  18. Pulsed spallation neutron sources

    International Nuclear Information System (INIS)

    Carpenter, J.M.

    1996-01-01

    This paper reviews the early history of pulsed spallation neutron source development ar Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provide a few examples of applications in fundamental condensed matter physics, materials science and technology

  19. Pulsed spallation Neutron Sources

    International Nuclear Information System (INIS)

    Carpenter, J.M.

    1994-01-01

    This paper reviews the early history of pulsed spallation neutron source development at Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provides a few examples of applications in fundamental condensed matter physics, materials science and technology

  20. The Goodwin model: simulating the effect of light pulses on the circadian sporulation rhythm of Neurospora crassa.

    Science.gov (United States)

    Ruoff, P; Vinsjevik, M; Monnerjahn, C; Rensing, L

    2001-03-07

    The Goodwin oscillator is a minimal model that describes the oscillatory negative feedback regulation of a translated protein which inhibits its own transcription. Now, over 30 years later this scheme provides a basic description of the central components in the circadian oscillators of Neurospora, Drosophila, and mammals. We showed previously that Neurospora's resetting behavior by pulses of temperature, cycloheximide or heat shock can be simulated by this model, in which degradation processes play an important role for determining the clock's period and its temperature-compensation. Another important environmental factor for the synchronization is light. In this work, we show that on the basis of a light-induced transcription of the frequency (frq) gene phase response curves of light pulses as well as the influence of the light pulse length on phase shifts can be described by the Goodwin oscillator. A relaxation variant of the model predicts that directly after a light pulse inhibition in frq -transcription occurs, even when the inhibiting factor Z (FRQ) has not reached inhibitory concentrations. This has so far not been experimentally investigated for frq transcription, but it complies with a current model of light-induced transcription of other genes by a phosphorylated white-collar complex. During long light pulses, the relaxational model predicts that the sporulation rhythm is arrested in a steady state of high frq -mRNA levels. However, experimental results indicate the possibility of oscillations around this steady state and more in favor of the results by the original Goodwin model. In order to explain the resetting behavior by two light pulses, a biphasic first-order kinetics recovery period of the blue light receptor or of the light signal transduction pathway has to be assumed. Copyright 2001 Academic Press.

  1. Pulse Oximetry

    Science.gov (United States)

    ... American Thoracic Society www. thoracic. org American Thoracic Society PATIENT EDUCATION | INFORMATION SERIES How accurate is the pulse oximeter? The ... patient. co. uk/ doctor/ Pulse- Oximetry. htm This ... service of the American Thoracic Society. The content is for educational purposes only. It ...

  2. Long-Term Survival of Leptospira in a Biphasic Culture Medium Containing Charcoal

    Science.gov (United States)

    Myers, Donald M.; Varela-Díaz, Victor M.; Siniuk, Alicia A.

    1973-01-01

    A comparison was made of the survival of 28 leptospiral serotypes in Fletcher semisolid medium and in the same medium containing a basal layer of Fletcher medium plus 0.7% of agar and 0.5% of activated animal charcoal. A year after culture, more motile leptospires were observed by microscope examination in the biphasic medium. Two years after culture, 4 serotypes grown in the biphasic medium and 11 in Fletcher medium did not show motile cells. Nineteen of the serotypes maintained in Fletcher medium and 25 in the biphasic medium for 2 years grew on subculture into Fletcher medium. Subcultures from the biphasic medium showed the characteristic leptospiral ring growth earlier during the incubation period. PMID:4735486

  3. Biphasic cuirass ventilation is better than bag-valve mask ventilation for resuscitation following organophosphate poisoning

    Directory of Open Access Journals (Sweden)

    Ilan Gur

    2015-01-01

    Conclusions: The noninvasive, easy-to-operate Biphasic Cuirass Ventilation device was effective in reducing OP-induced mortality and might be advantageous in an organophosphate mass casualty event. This finding should be validated in further investigations.

  4. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  5. Biphasic influence of dexamethasone exposure on embryonic vertebrate skeleton development

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Xin; Chen, Jian-long; Ma, Zheng-lai; Zhang, Zhao-long; Lv, Shun; Mai, Dong-mei; Liu, Jia-jia [Department of Histology and Embryology, Key Laboratory for Regenerative Medicine of the Ministry of Education, School of Medicine, Jinan University, Guangzhou 510632 (China); Chuai, Manli [Division of Cell and Developmental Biology, University of Dundee, Dundee DD1 5EH (United Kingdom); Lee, Kenneth Ka Ho; Wan, Chao [Stem Cell and Regeneration Thematic Research Programme, School of Biomedical Sciences, Chinese University of Hong Kong, Shatin (Hong Kong); Yang, Xuesong, E-mail: yang_xuesong@126.com [Department of Histology and Embryology, Key Laboratory for Regenerative Medicine of the Ministry of Education, School of Medicine, Jinan University, Guangzhou 510632 (China); Institute of Fetal-Preterm Labor Medicine, Jinan University, Guangzhou 510632 (China)

    2014-11-15

    increased in mesenchymal cell mass treated by low concentration of Dex. Mmp-13 expression was obviously up-regulated by Dex in both mesenchymal cells and primary chondrocyte cultures. And Col10a1 expression was also increased by Dex exposure in chondrocyte. In summary, we have revealed that different concentrations of Dex exposure during early gestation could exert a biphasic effect on vertebrate skeletal development. - Highlights: • Chick embryos occurred shortening of the long bone following Dex exposure. • Dex suppressed chondrocytes proliferation and promoted apoptosis. • Dex exposure decreased ALP production and up-regulated Runx-2 and Mmp-13. • Dex exhibited biphasic effects on chondrogenic proliferation and nodule formation. • The hypertrophy and ossification were accelerated by Dex both in vivo and in vitro.

  6. Biphasic influence of dexamethasone exposure on embryonic vertebrate skeleton development

    International Nuclear Information System (INIS)

    Cheng, Xin; Chen, Jian-long; Ma, Zheng-lai; Zhang, Zhao-long; Lv, Shun; Mai, Dong-mei; Liu, Jia-jia; Chuai, Manli; Lee, Kenneth Ka Ho; Wan, Chao; Yang, Xuesong

    2014-01-01

    in mesenchymal cell mass treated by low concentration of Dex. Mmp-13 expression was obviously up-regulated by Dex in both mesenchymal cells and primary chondrocyte cultures. And Col10a1 expression was also increased by Dex exposure in chondrocyte. In summary, we have revealed that different concentrations of Dex exposure during early gestation could exert a biphasic effect on vertebrate skeletal development. - Highlights: • Chick embryos occurred shortening of the long bone following Dex exposure. • Dex suppressed chondrocytes proliferation and promoted apoptosis. • Dex exposure decreased ALP production and up-regulated Runx-2 and Mmp-13. • Dex exhibited biphasic effects on chondrogenic proliferation and nodule formation. • The hypertrophy and ossification were accelerated by Dex both in vivo and in vitro

  7. AQUEOUS BIPHASE EXTRACTION FOR PROCESSING OF FINE COAL

    Energy Technology Data Exchange (ETDEWEB)

    K. Osseo-Asare; X. Zeng

    2001-06-30

    Ever-stringent environmental constraints dictate that future coal cleaning technologies be compatible with micron-size particles. This research program seeks to develop an advanced coal cleaning technology uniquely suited to micron-size particles, i.e., aqueous biphase extraction. The partitioning behaviors of silica in the polyethylene glycol (PEG)/dextran (Dex) and dextran/Triton X-100 (TX100) systems have been investigated, and the effects of sodium dodecylsulfate (SDS) and dodecyltrimethylammonium bromide (DTAB) on solid partition have been studied. In both biphase systems, silica particles stayed in the top PEG-rich phase at low pH. With increase in pH, the particles moved from the top phase to the interface, then to the bottom phase. At very high pH, the solids preferred the top phase again. These trends are attributable to variations in the polymer/solid and nonionic surfactant/solid interactions. Addition of ionic surfactants into these two systems introduces a weakly charged environment, since ionic surfactants concentrate into one phase, either the top phase or the bottom phase. Therefore, coulombic forces also play a key role in the partition of silica particles because electrostatic attractive or repulsive forces are produced between the solid surface and the ionic-surfactant-concentrated phase. For the PEG/dextran system in the presence of SDS, SiO{sub 2} preferred the bottom dextran-rich phase above its pH{sub PZC}. However, addition of DTAB moved the oxide particles from the top phase to the interface, and then to the bottom phase, with increase in pH. These different behaviors are attributable to the fact that SDS and DTAB concentrated into the opposite phase of the PEG/dextran system. On the other hand, in the dextran/Triton X-100 system, both ionic surfactants concentrated in the top surfactant-rich phase and formed mixed micelles with TX100. Therefore, addition of the anionic surfactant, SDS, moved the silica particles from top phase to the

  8. Pulsed Corona Discharge Generated By Marx Generator

    Science.gov (United States)

    Sretenovic, G. B.; Obradovic, B. M.; Kovacevic, V. V.; Kuraica, M. M.; Puric J.

    2010-07-01

    The pulsed plasma has a significant role in new environmental protection technologies. As a part of a pulsed corona system for pollution control applications, Marx type repetitive pulse generator was constructed and tested in arrangement with wire-plate corona reactor. We performed electrical measurements, and obtained voltage and current signals, and also power and energy delivered per pulse. Ozone formation by streamer plasma in air was chosen to monitor chemical activity of the pulsed corona discharge.

  9. Biphasic oxidation of oxy-hemoglobin in bloodstains.

    Directory of Open Access Journals (Sweden)

    Rolf H Bremmer

    Full Text Available BACKGROUND: In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO(2 to met-hemoglobin (met-Hb and hemichrome (HC. The fractions of HbO(2, met-Hb and HC in a bloodstain can be used for age determination of bloodstains. In this study, we further analyze the conversion of HbO(2 to met-Hb and HC, and determine the effect of temperature and humidity on the conversion rates. METHODOLOGY: The fractions of HbO(2, met-Hb and HC in a bloodstain, as determined by quantitative analysis of optical reflectance spectra (450-800 nm, were measured as function of age, temperature and humidity. Additionally, Optical Coherence Tomography around 1300 nm was used to confirm quantitative spectral analysis approach. CONCLUSIONS: The oxidation rate of HbO(2 in bloodstains is biphasic. At first, the oxidation of HbO(2 is rapid, but slows down after a few hours. These oxidation rates are strongly temperature dependent. However, the oxidation of HbO(2 seems to be independent of humidity, whereas the transition of met-Hb into HC strongly depends on humidity. Knowledge of these decay rates is indispensable for translating laboratory results into forensic practice, and to enable bloodstain age determination on the crime scene.

  10. Aqueous biphasic systems involving alkylsulfate-based ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Deive, Francisco J. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Rodriguez, Ana [Department of Chemical Engineering, University of Vigo, P.O. Box 36310, Vigo (Spain); Marrucho, Isabel M., E-mail: imarrucho@itqb.unl.pt [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal); Rebelo, Luis P.N. [Instituto de Tecnologia Quimica e Biologica, UNL, Av. Republica, Apartado 127, 2780-901 Oeiras (Portugal)

    2011-11-15

    Highlights: > K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4} act as phase promoter in aqueous solutions of ILs. > Remarkable influence of alkyl-chain length on solubility curves of alkylsulfate-based ILs. > Merchuck correlation was used for describing these systems. > {Delta}S{sub hyd} and Hofmeister series were used to discuss the different salting out effects. - Abstract: The specific effects of K{sub 3}PO{sub 4}, K{sub 2}CO{sub 3}, Na{sub 2}CO{sub 3}, and (NH{sub 4}){sub 2}SO{sub 4}, as high charge-density inorganic salts and thus inducers of the formation of aqueous biphasic systems (ABS) containing several ethyl-methylimidazolium alkylsulfate ionic liquids, C{sub 2}MIM C{sub n}SO{sub 4} (n = 2, 4, 6, or 8), have been assessed at T = 298.15 K. The results are analyzed in the light of the Hofmeister series. The influence of different alkyl chain lengths in the anion, together with the ability of the selected inorganic salts to induce the formation of ABS, is discussed. Phase diagrams have been determined through turbidimetry, including tie lines assignments from mass phase ratios according to the lever - arm rule. The Merchuck equation was satisfactorily used to correlate the solubility curve.

  11. Comparison between FEBio and Abaqus for biphasic contact problems.

    Science.gov (United States)

    Meng, Qingen; Jin, Zhongmin; Fisher, John; Wilcox, Ruth

    2013-09-01

    Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of this study was to undertake a direct comparison between FEBio and Abaqus for some practical contact problems involving cartilage. Three model types, representing a porous flat-ended indentation test, a spherical-ended indentation test, and a conceptual natural joint contact model, were compared. In addition, a parameter sensitivity study was also performed for the spherical-ended indentation test to investigate the effects of changes in the input material properties on the model outputs, using both FEBio and Abaqus. Excellent agreement was found between FEBio and Abaqus for all of the model types and across the range of material properties that were investigated.

  12. Rapid thermal annealing effect on the spatial resistivity distribution of AZO thin films deposited by pulsed-direct-current sputtering for solar cells applications

    Energy Technology Data Exchange (ETDEWEB)

    Ayachi, Boubakeur, E-mail: boubakeur.ayachi@ed.univ-lille1.fr [Institute of Electronics, Microelectronics and Nanotechnology, Lille 1 University, Avenue Poincaré, UMR 8520, CS 60069, Villeneuve d’Ascq 59652 (France); Aviles, Thomas [CROSSLUX, Avenue Georges Vacher, ZI Rousset Peynier, Immeuble CCE, Rousset 13106 (France); Vilcot, Jean-Pierre [Institute of Electronics, Microelectronics and Nanotechnology, Lille 1 University, Avenue Poincaré, UMR 8520, CS 60069, Villeneuve d’Ascq 59652 (France); Sion, Cathy [Institute of Electronics, Microelectronics and Nanotechnology, Lille 1 University, Avenue Poincaré, UMR 8520, CS 60069, Villeneuve d’Ascq 59652 (France); Ecole Centrale Lille, Cité Scientifique – CS20048, Villeneuve d’Ascq 59651 (France)

    2016-03-15

    Graphical abstract: - Highlights: • High quality pulsed-DC sputtered AZO thin films were obtained after RTA treatment. • RTA for 30 s was sufficient to achieve uniform spatial resistivity distribution. • RTA for longer than 1 min showed a small increase in resistivity value. • Such improvement was attributed to grain boundaries passivation and doping activation. • In the framework of low cost solar cells development, RTA process would be helpful. - Abstract: Room temperature deposited aluminium-doped zinc oxide thin films on glass substrate, using pulsed-DC magnetron sputtering, have shown high optical transmittance and low electrical resistivity with high uniformity of its spatial distribution after they were exposed to a rapid thermal annealing process at 400 °C under N{sub 2}H{sub 2} atmosphere. It is particularly interesting to note that such an annealing process of AZO thin films for only 30 s was sufficient, on one hand to improve their optical transmittance from 73% to 86%, on the other hand to both decrease their resistivity from 1.7 × 10{sup −3} Ω cm to 5.1 × 10{sup −4} Ω cm and achieve the highest uniformity spatial distribution. To understand the mechanisms behind such improvements of the optoelectronic properties, electrical, optical, structural and morphological changes as a function of annealing time have been investigated by using hall measurement, UV–visible spectrometry, X-ray diffraction and scanning electron microscope imaging, respectively.

  13. High-Voltage, Multiphasic, Nanosecond Pulses to Modulate Cellular Responses.

    Science.gov (United States)

    Ryan, Hollie A; Hirakawa, Shinji; Yang, Enbo; Zhou, Chunrong; Xiao, Shu

    2018-04-01

    Nanosecond electric pulses are an effective power source in plasma medicine and biological stimulation, in which biophysical responses are governed by peak power and not energy. While uniphasic nanosecond pulse generators are widely available, the recent discovery that biological effects can be uniquely modulated by reversing the polarity of nanosecond duration pulses calls for the development of a multimodal pulse generator. This paper describes a method to generate nanosecond multiphasic pulses for biomedical use, and specifically demonstrates its ability to cancel or enhance cell swelling and blebbing. The generator consists of a series of the fundamental module, which includes a capacitor and a MOSFET switch. A positive or a negative phase pulse module can be produced based on how the switch is connected. Stacking the modules in series can increase the voltage up to 5 kV. Multiple stacks in parallel can create multiphase outputs. As each stack is independently controlled and charged, multiphasic pulses can be created to produce flexible and versatile pulse waveforms. The circuit topology can be used for high-frequency uniphasic or biphasic nanosecond burst pulse production, creating numerous opportunities for the generator in electroporation applications, tissue ablation, wound healing, and nonthermal plasma generation.

  14. APPROXIMATE CALCULATION OF ACTIVE RESISTANCE AND TEMPERATURE OF THE PULSE ELECTRIC ARC CHANNEL IN A HIGH-CURRENT DISCHARGE CIRCUIT OF A POWERFUL HIGH-VOLTAGE CAPACITOR ENERGY STORAGE

    Directory of Open Access Journals (Sweden)

    M.I. Baranov

    2017-08-01

    Full Text Available Purpose. To obtain calculation correlations for active resistance Rce and maximal temperature Tme of plasma channel of pulse electric arc in the air double-electrode system (DES with metal (graphite electrodes, and also practical approbation of the obtained correlations for Rce and Tme in the conditions of high-voltage laboratory on the powerful capacity energy storage (CES of electric setting, intended for reproducing on the electric loading of protracted C- component of current of artificial lightning with the USA rationed on normative documents by amplitude-temporal parameters (ATP. Methodology. Electrophysics bases of high-voltage impulse technique, scientific and technical bases of development and creation of high-voltage high-current impulse electrical equipment, including powerful CES, and also measuring methods in discharge circuits of powerful high-voltage CES of pulse currents of millisecond temporal range. Results. On the basis of engineering approach the new results of approximate calculation of values of Rce and Tme are resulted in the plasma channel of pulse electric arc discharge in air DES of atmospheric pressure with metallic (graphite electrodes. Practical approbation of results of calculation of values of Rce and Tme is executed as it applies to air DES, to connected in a discharge circuit of powerful high-voltage CES with protracted C- of component current of artificial lightning, characterized rationed ATP. It is shown that calculation of numeral value Rce approximately in 100 times exceeds the proper value of active resistance for the plasma channel of impulsive spark of electric discharge in air DES other things being equal, and a calculation of numeral value Tme well corresponds with the known thermodynamics information for classic electric arc in air DES of atmospheric pressure with graphite electrodes. Originality. New engineering approach is developed for the approximate calculation of values of Rce and Tme in electron

  15. Differential pulse code modulation

    Science.gov (United States)

    Herman, C. F. (Inventor)

    1976-01-01

    A differential pulse code modulation (DPCM) encoding and decoding method is described along with an apparatus which is capable of transmission with minimum bandwidth. The apparatus is not affected by data transition density, requires no direct current (DC) response of the transmission link, and suffers from minimal ambiguity in resolution of the digital data.

  16. Design and evaluation of lornoxicam bilayered tablets for biphasic release

    Directory of Open Access Journals (Sweden)

    Songa Ambedkar Sunil

    2012-12-01

    Full Text Available The objective of the present investigation was to develop bilayered tablets of lornoxicam to achieve biphasic release pattern. A bilayered tablet, consisting of an immediate and controlled release layer, was prepared by direct compression technique. The controlled release effect was achieved by using various hydrophilic natural, semi synthetic and synthetic controlled release polymers such as xanthan gum, hydroxypropyl methylcellulose (HPMC and polyethylene oxide (PEO to modulate the release of the drug. The in vitro drug release profiles showed the biphasic release behavior in which the immediate release (IR layer containing the lornoxicam was released within 15 minutes, whereas the controlled release (CR layer controlled the drug release for up to 24 h. All the bilayered tablets formulated have followed the zero order release with non-Fickian diffusion controlled release mechanism after the initial burst release. FTIR studies revealed that there was no interaction between the drug and polymers used in the study. Statistical analysis (ANOVA showed no significant difference in the cumulative amount of drug release after 15 min, but significant difference (p O objetivo do presente trabalho foi desenvolver comprimidos bicamada de lornoxicam para atingir padrão de liberação bifásica. Preparou-se, por compressão direta, comprimido bicamada, consistindo de uma camada de liberação imediata e uma de liberação controlada. A liberação controlada foi obtida pelo uso de vários polímeros naturais hidrofílicos, semi-sintéticos e sintéticos, tais como goma xantana, hidroxipropilmetil celulose (HPMC e óxido de polietileno (PEO para modular a liberação do fármaco. Os perfis de liberação in vitro mostraram comportamento bifásico em que a camada de liberação imediata (IR contendo lornoxicam foi liberada em 15 minutos, enquanto a camada de liberação controlada (CR liberou o fármaco em mais de 24 horas, Todos os comprimidos bicamada

  17. Biphasic Peptide Amphiphile Nanomatrix Embedded with Hydroxyapatite Nanoparticles for Stimulated Osteoinductive Response

    Science.gov (United States)

    Anderson, Joel M.; Patterson, Jessica L.; Vines, Jeremy B.; Javed, Amjad; Gilbert, Shawn R.; Jun, Ho-Wook

    2013-01-01

    Formation of the native bone extracellular matrix (ECM) provides an attractive template for bone tissue engineering. The structural support and biological complexity of bone ECM are provided within a composite microenvironment that consists of an organic fibrous network reinforced by inorganic hydroxyapatite (HA) nanoparticles. Recreating this biphasic assembly, a bone ECM analogous scaffold comprised of self-assembling peptide amphiphile (PA) nanofibers and interspersed HA nanoparticles was investigated. PAs were endowed with biomolecular ligand signaling using a synthetically inscribed peptide sequence (i.e. RGDS) and integrated with HA nanoparticles to form a biphasic nanomatrix hydrogel. It was hypothesized the biphasic hydrogel would induce osteogenic differentiation of human mesenchymal stem cells (hMSCs) and improve bone healing as mediated by RGDS ligand signaling within PA nanofibers and embedded HA mineralization source. Viscoelastic stability of the biphasic PA hydrogels was evaluated with different weight concentrations of HA for improved gelation. After demonstrating initial viability, long-term cellularity and osteoinduction of encapsulated hMSCs in different PA hydrogels were studied in vitro. Temporal progression of osteogenic maturation was assessed by gene expression of key markers. A preliminary animal study demonstrated bone healing capacity of the biphasic PA nanomatrix under physiological conditions using a critical size femoral defect rat model. The combination of RGDS ligand signaling and HA nanoparticles within the biphasic PA nanomatrix hydrogel demonstrated the most effective osteoinduction and comparative bone healing response. Therefore, the biphasic PA nanomatrix establishes a well-organized scaffold with increased similarity to natural bone ECM with the prospect for improved bone tissue regeneration. PMID:22077993

  18. Pulsed helium ionization detection system

    Science.gov (United States)

    Ramsey, R.S.; Todd, R.A.

    1985-04-09

    A helium ionization detection system is provided which produces stable operation of a conventional helium ionization detector while providing improved sensitivity and linearity. Stability is improved by applying pulsed dc supply voltage across the ionization detector, thereby modifying the sampling of the detectors output current. A unique pulse generator is used to supply pulsed dc to the detector which has variable width and interval adjust features that allows up to 500 V to be applied in pulse widths ranging from about 150 nsec to about dc conditions.

  19. Core-shell nanoreactors for efficient aqueous biphasic catalysis.

    Science.gov (United States)

    Zhang, Xuewei; Cardozo, Andrés F; Chen, Si; Zhang, Wenjing; Julcour, Carine; Lansalot, Muriel; Blanco, Jean-François; Gayet, Florence; Delmas, Henri; Charleux, Bernadette; Manoury, Eric; D'Agosto, Franck; Poli, Rinaldo

    2014-11-17

    Water-borne phosphine-functionalized core-cross-linked micelles (CCM) consisting of a hydrophobic core and a hydrophilic shell were obtained as stable latexes by reversible addition-fragmentation chain transfer (RAFT) in water in a one-pot, three-step process. Initial homogeneous aqueous-phase copolymerization of methacrylic acid (MAA) and poly(ethylene oxide) methyl ether methacrylate (PEOMA) is followed by copolymerization of styrene (S) and 4-diphenylphosphinostyrene (DPPS), yielding P(MAA-co-PEOMA)-b-P(S-co-DPPS) amphiphilic block copolymer micelles (M) by polymerization-induced self-assembly (PISA), and final micellar cross-linking with a mixture of S and diethylene glycol dimethacrylate. The CCM were characterized by dynamic light scattering and NMR spectroscopy to evaluate size, dispersity, stability, and the swelling ability of various organic substrates. Coordination of [Rh(acac)(CO)2 ] (acac=acetylacetonate) to the core-confined phosphine groups was rapid and quantitative. The CCM and M latexes were then used, in combination with [Rh(acac)(CO)2 ], to catalyze the aqueous biphasic hydroformylation of 1-octene, in which they showed high activity, recyclability, protection of the activated Rh center by the polymer scaffold, and low Rh leaching. The CCM latex gave slightly lower catalytic activity but significantly less Rh leaching than the M latex. A control experiment conducted in the presence of the sulfoxantphos ligand pointed to the action of the CCM as catalytic nanoreactors with substrate and product transport into and out of the polymer core, rather than as a surfactant in interfacial catalysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Ascending-ramp biphasic waveform has a lower defibrillation threshold and releases less troponin I than a truncated exponential biphasic waveform.

    Science.gov (United States)

    Huang, Jian; Walcott, Gregory P; Ruse, Richard B; Bohanan, Scott J; Killingsworth, Cheryl R; Ideker, Raymond E

    2012-09-11

    We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold but also the amount of cardiac damage. Defibrillation thresholds were determined for 11 waveforms-3 ascending-ramp waveforms, 3 descending-ramp waveforms, 3 rectilinear first-phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform-in 6 pigs with electrodes in the right ventricular apex and superior vena cava. The ascending, descending, and rectilinear waveforms had 4-, 8-, and 16-millisecond first phases and a 3.5-millisecond rectilinear second phase that was half the voltage of the first phase. The exponential biphasic waveform had a 60% first-phase and a 50% second-phase tilt. In a second study, we attempted to defibrillate after 10 seconds of ventricular fibrillation with a single ≈30-J shock (6 pigs successfully defibrillated with 8-millisecond ascending, 8-millisecond rectilinear, and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hours after the shock. The lowest-energy defibrillation threshold was for the 8-milliseconds ascending ramp (14.6±7.3 J [mean±SD]), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours after shock, troponin I was significantly less for the ascending-ramp waveform (0.80±0.54 ng/mL) than for the truncated exponential (1.92±0.47 ng/mL) or the rectilinear waveform (1.17±0.45 ng/mL). The ascending ramp has a significantly lower defibrillation threshold and at ≈30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the defibrillation threshold and the amount of cardiac damage.

  1. An Ascending Ramp Biphasic Waveform Has a Lower Defibrillation Threshold and Releases Less Troponin I Than a Truncated Exponential Biphasic Waveform

    Science.gov (United States)

    Huang, Jian; Walcott, Gregory P.; Ruse, Richard B.; Bohanan, Scott J.; Killingsworth, Cheryl R.; Ideker, Raymond E.

    2014-01-01

    Background We tested the hypothesis that the shape of the shock waveform affects not only the defibrillation threshold (DFT), but also the amount of cardiac damage. Methods and Results DFTs were determined for 11 waveforms: 3 ascending ramp, 3 descending ramp, and 3 rectilinear first phase biphasic waveforms, a Gurvich waveform, and a truncated exponential biphasic waveform in 6 pigs with electrodes in the RV apex and SVC. The ascending, descending and rectilinear waveforms had 4, 8 and 16 ms 1st phases and a 3.5 ms 2nd rectilinear phase half the voltage of the 1st phase. The exponential biphasic waveform had a 60% 1st phase and a 50% 2nd phase tilt. In a second study, we attempted to defibrillate after 10 s of VF with a single ≈ 30 J shock (6 pigs successfully defibrillated with 8 ms ascending, 8 ms rectilinear wave and truncated exponential biphasic waveforms). Troponin I blood levels were determined before and 2 to 10 hrs after the shock. The lowest energy DFT was for the 8 ms ascending ramp (14.6±7.3 SD J), which was significantly less than for the truncated exponential (19.6±6.3 J). Six hours postshock, troponin I in ng/ml was significantly less for the ascending ramp (0.80±0.54) than for the truncated exponential (1.92±0.47) or the rectilinear waveform (1.17 ±0.45). Conclusions The ascending ramp has a significantly lower DFT, and at ≈ 30 J causes 58% less troponin I release than the truncated exponential biphasic shock. Therefore, the shock waveform affects both the DFT and the amount of cardiac damage. PMID:22865891

  2. Electrical resistivity change in Al:ZnO thin films dynamically deposited by bipolar pulsed direct-current sputtering and a remote plasma source

    International Nuclear Information System (INIS)

    Yang, Wonkyun; Joo, Junghoon

    2010-01-01

    The Al-doped ZnO (AZO) thin films for a transparent conducting oxide in solar cell devices were deposited by bipolar pulsed dc magnetron sputtering. This work was performed in an in-line type system and investigated AZO films in a static deposition mode and dynamic one, which is more important in the practical fields. Because of this dynamic deposition process, the zigzagged columnar structure was observed. This resulted in the decreasing electrical property, optical properties, and surface roughness. As a deposition in the dynamic mode, the resistivity increased from 1.64x10 -3 to 2.50x10 -3 Ω cm, as compared to that in the static mode, and the transmittance also decreased from 83.9% to 78.3%. To recover the disadvantage, a remote plasma source (RPS) was supported between the substrate and target for reducing zigzagged formation during the deposition. The deposition rate decreased by using RPS, but the electrical and optical properties of films got better than only dynamic mode. The resistivity and transmittance in the dynamic mode using RPS were 2.1x10 -3 Ω cm and 85.5%, respectively. In this study, the authors found the possibility to advance the electrical and optical properties of AZO thin films in the industry mode.

  3. Evaluation of the finite element software ABAQUS for biomechanical modelling of biphasic tissues.

    Science.gov (United States)

    Wu, J Z; Herzog, W; Epstein, M

    1998-02-01

    The biphasic cartilage model proposed by Mow et al. (1980) has proven successful to capture the essential mechanical features of articular cartilage. In order to analyse the joint contact mechanics in real, anatomical joints, the cartilage model needs to be implemented into a suitable finite element code to approximate the irregular surface geometries of such joints. However, systematic and extensive evaluation of the capacity of commercial software for modelling the contact mechanics with biphasic cartilage layers has not been made. This research was aimed at evaluating the commercial finite element software ABAQUS for analysing biphasic soft tissues. The solutions obtained using ABAQUS were compared with those obtained using other finite element models and analytical solutions for three numerical tests: an unconfined indentation test, a test with the contact of a spherical cartilage surface with a rigid plate, and an axi-symmetric joint contact test. It was concluded that the biphasic cartilage model can be implemented into the commercial finite element software ABAQUS to analyse practical joint contact problems with biphasic articular cartilage layers.

  4. TSDC and impedance spectroscopy measurements on hydroxyapatite, β-tricalcium phosphate and hydroxyapatite/β-tricalcium phosphate biphasic bioceramics

    Science.gov (United States)

    Prezas, P. R.; Melo, B. M. G.; Costa, L. C.; Valente, M. A.; Lança, M. C.; Ventura, J. M. G.; Pinto, L. F. V.; Graça, M. P. F.

    2017-12-01

    Bone grafting and surgical interventions related with orthopaedic disorders consist in a big business, generating large revenues worldwide every year. There is a need to replace the biomaterials that currently still dominate this market, i.e., autografts and allografts, due to their disadvantages, such as limited availability, need for additional surgeries and diseases transmission possibilities. The most promising replacement materials are biomaterials with bioactive properties, such as the calcium phosphate-based bioceramics group. The bioactivity of these materials, i.e., the rate at which they promote the growth and directly bond with the new host biological bone, can be enhanced through their electrical polarization. In the present work, the electrical polarization features of pure hydroxyapatite (Hap), pure β-tricalcium phosphate (β-TCP) and biphasic hydroxyapatite/β-tricalcium phosphate composites (HTCP) were analyzed by measuring thermally stimulated depolarization currents (TSDC). The samples were thermoelectrically polarized at 500 °C under a DC electric field with a magnitude of 5 kV/cm. The biphasic samples were also polarized under electric fields with different magnitudes: 2, 3, 4 and 5 kV/cm. Additionally, the depolarization processes detected in the TSDC measurements were correlated with dielectric relaxation processes observed in impedance spectroscopy (IS) measurements. The results indicate that the β-TCP crystalline phase has a considerable higher ability to store electrical charge compared with the Hap phase. This indicates that it has a suitable composition and structure for ionic conduction and establishment of a large electric charge density, providing great potential for orthopaedic applications.

  5. <3> OMEGA pulse-forming network

    CERN Multimedia

    1974-01-01

    Adjustement of the 3 W pulse-forming network of the SPS beam dumping system. When charged at 60 kV, this PFN gives 10 kA, 25 ms current pulses, with oscillations, superimposed on the pulse flat top, of an amplitude of +/- 1 Ka.

  6. Polyethylene glycol-based aqueous biphasic systems: Inexpensive, nontoxic alternatives for Hanford tank remediation

    International Nuclear Information System (INIS)

    Rogers, R.D.; Bond, A.H.; Bauer, C.B.; Song, Y.; Zhang, J.; Chomko, R.R.

    1994-01-01

    The potential for cleaner, cheaper, safer separations technologies with polyethylene glycol (PEG)-based aqueous biphasic systems stems from the inexpensive, nontoxic, nonflammable nature, and general availability of the PEG and inorganic salts which form them, and the lack of organic diluent. The authors have demonstrated that simulants of the highly alkaline waste stored at Westinghouse Hanford will induce biphase formation when contacted with aqueous PEG-2000 solutions. They have also demonstrated that the long lived and environmentally mobile radioactive ions 99 TcO 4 - and 129 I - can be partitioned from the salt rich to the PEG-rich phase in these aqueous biphasic systems. In addition, they have shown that Group 1 and 2 cation extraction can be accomplished from highly alkaline systems via addition of an appropriate water-soluble extractant. This paper focuses on the factors affecting the distribution ratios and the work on developing a viable separations process

  7. Biphasic Synergistic Gel Materials with Switchable Mechanics and Self-Healing Capacity.

    Science.gov (United States)

    Zhao, Ziguang; Liu, Yuxia; Zhang, Kangjun; Zhuo, Shuyun; Fang, Ruochen; Zhang, Jianqi; Jiang, Lei; Liu, Mingjie

    2017-10-16

    A fabrication strategy for biphasic gels is reported, which incorporates high-internal-phase emulsions. Closely packed micro-inclusions within the elastic hydrogel matrix greatly improve the mechanical properties of the materials. The materials exhibit excellent switchable mechanics and shape-memory performance because of the switchable micro- inclusions that are incorporated into the hydrogel matrix. The produced materials demonstrated a self-healing capacity that originates from the noncovalent effect of the biphasic heteronetwork. The aforementioned characteristics suggest that the biphasic gels may serve as ideal composite gel materials with validity in a variety of applications, such as soft actuators, flexible devices, and biological materials. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Biphasic fluence-response curves for phytochrome-mediated kalanchoë seed germination : sensitization by gibberellic Acid.

    Science.gov (United States)

    Rethy, R; Dedonder, A; De Petter, E; Van Wiemeersch, L; Fredericq, H; De Greef, J; Steyaert, H; Stevens, H

    1987-01-01

    The fluence-response curves for the effect of two red pulses separated by 24 hours on the germination of Kalanchoe blossfeldiana Poelln. cv Vesuv seeds, incubated on gibberellic acid (GA(3)) are biphasic for suboptimal concentrations. The response in the low fluence range corresponds with a classical red/far-red reversible phytochrome mediated reaction. GA(3) induces an additional response in the very low fluence range, which is also phytochrome mediated. The sensitivity to phytochrome-far-red absorbing form (Pfr), however, is increased about 20,000-fold, so that even far-red fluences become saturating. Both in the very low and low fluence response range, the maximal responses induced by saturating fluences are modulated by the GA(3) concentration. GA(3) having no direct influence on the phytochrome phototransformations, alters the Pfr requirement and determines the responding seed population fraction in the very low and low fluence range. The effet of GA(3) appears to be on the transduction chain of the phytochrome signal.

  9. A Structurally and Functionally Biomimetic Biphasic Scaffold for Intervertebral Disc Tissue Engineering

    Science.gov (United States)

    Choy, Andrew Tsz Hang; Chan, Barbara Pui

    2015-01-01

    Tissue engineering offers high hopes for the treatment of intervertebral disc (IVD) degeneration. Whereas scaffolds of the disc nucleus and annulus have been extensively studied, a truly biomimetic and mechanically functional biphasic scaffold using naturally occurring extracellular matrix is yet to be developed. Here, a biphasic scaffold was fabricated with collagen and glycosaminoglycans (GAGs), two of the most abundant extracellular matrix components in the IVD. Following fabrication, the scaffold was characterized and benchmarked against native disc. The biphasic scaffold was composed of a collagen-GAG co-precipitate making up the nucleus pulposus-like core, and this was encapsulated in multiple lamellae of photochemically crosslinked collagen membranes comprising the annulus fibrosus-like lamellae. On mechanical testing, the height of our engineered disc recovered by ~82-89% in an annulus-independent manner, when compared with the 99% recovery exhibited by native disc. The annulus-independent nature of disc height recovery suggests that the fluid replacement function of the engineered nucleus pulposus core might mimic this hitherto unique feature of native disc. Biphasic scaffolds comprised of 10 annulus fibrosus-like lamellae had the best overall mechanical performance among the various designs owing to their similarity to native disc in most aspects, including elastic compliance during creep and recovery, and viscous compliance during recovery. However, the dynamic mechanical performance (including dynamic stiffness and damping factor) of all the biphasic scaffolds was similar to that of the native discs. This study contributes to the rationalized design and development of a biomimetic and mechanically viable biphasic scaffold for IVD tissue engineering. PMID:26115332

  10. The standard biphasic-contrast examination of the stomach and duodenum

    International Nuclear Information System (INIS)

    Op den Orth, J.O.

    1979-01-01

    A standard examination has been developed, called biphasic, because it combines the advantages of positive-contrast and double-contrast techniques. The theoretical background and technique of this examination are described and the basic interpretation of double-contrast studies stated. General remarks on the results and on the complementary role of radiological examination and endoscopy are included. A quantitative study of standard biphasic-contrast examinations in patients over a period of 3 years is presented. Finally a radiological atlas of common lesions of the stomach and duodenum is given. (C.F.)

  11. Micrometer-scale mixing with Pickering emulsions: biphasic reactions without stirring.

    Science.gov (United States)

    Zhang, Wenjuan; Fu, Luman; Yang, Hengquan

    2014-02-01

    A general strategy that avoids stirring for organic/aqueous reactions involving solid catalysts is reported. The strategy involves converting a conventional biphasic system into a Pickering emulsion phase with micrometer-scale droplets ensuring good mixing. In test reactions, nitrotoluene reduction and epoxidation of allylic alcohols, the reaction efficiency is comparable to conventional stirrer-driven biphasic catalysis reaction systems. Short diffusion distances, arising from the compartmentalization of densely packed droplets, play an important role in boosting the reaction efficiency. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Design and Characteristic Analysis of Multicarrier Chaotic Phase Coded Radar Pulse Train Signal

    OpenAIRE

    Huang, Qiongdan; Li, Yong; Zeng, Yaoping; Fu, Yinjuan

    2014-01-01

    By introducing phase code into multicarrier orthogonal frequency division multiplex signal, the multicarrier phase coded (MCPC) radar signal possesses a good spectrum utilization rate and can achieve a good combination of narrowband and wideband processing. Radar pulse train signal not only reserves the high range resolution of monopulse signal, but also has the same velocity resolution performance as continuous wave signal does. In this study, we use the chaotic biphase code generated by Che...

  13. Pulsed power

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The key element of our pulsed power program is concentration of power in time and space by suppression of breakdown in dielectrics and in vacuum. Magnetically insulated vacuum transmission lines and magnetic suppression of insulator flashover have continued as the main reserch directions. Vacuum insulated line studies at Physics International have been expanded and a test bed at Sandia, called MITE (Magnetically Insulated Transmission Experiment), is under development. The choice for the baseline EBFA design will depend on the outcome of these studies and should be made in July 1977. The slow and intermediate speed pulsed power approaches to EBFA will be based on Proto I and Proto II results and several of the projected EBFA subsystems are presently being tested in Proto II. A further stage of power concentration, within the vacuum diode itself, would considerably ease the burden on dielectrics; methods of power multiplication involving magnetically imploded plasmas are being considered and tests have begun using the Ripple III apparatus

  14. Limits of applicability of a time-of-flight ion-mass analyzer in uncovering partial currents of ions emitted by pulsed laser ion sources

    Czech Academy of Sciences Publication Activity Database

    Krása, Josef; Láska, Leoš; Rohlena, Karel; Velyhan, Andriy; Czarnecka, A.; Parys, P.; Ryc, L.; Wolowski, J.

    2010-01-01

    Roč. 165, 6-10 (2010), s. 441-450 ISSN 1042-0150 R&D Projects: GA MŠk(CZ) LC528; GA AV ČR IAA100100715 EU Projects: European Commission(XE) 228334 - LASERLAB-EUROPE Institutional research plan: CEZ:AV0Z10100523 Keywords : laser-produced plasma * time-resolved current deconvolution * ion velocity distribution * drift velocity of ions Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.660, year: 2010

  15. Biphase Cobalt-Manganese Oxide with High Capacity and Rate Performance for Aqueous Sodium-Ion Electrochemical Energy Storage

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Xiaoqiang [Univ. of New Hampshire, Durham, NH (United States). Dept. of Chemical Engineering; Charles, Daniel S. [Univ. of New Hampshire, Durham, NH (United States). Dept. of Chemical Engineering; Xu, Wenqian [Argonne National Lab. (ANL), Argonne, IL (United States). Advanced Photon Source (APS). X-ray Science Division; Feygenson, Mikhail [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Chemical and Engineering Materials Division and Spallation Neutron Source (SNS) outstation Juelich Centre for Neutron Science (JCNS), Forschungszentrum Juelich GmbH; Su, Dong [Brookhaven National Lab. (BNL), Upton, NY (United States). Center for Functional Nanomaterials (CFN); Teng, Xiaowei [Univ. of New Hampshire, Durham, NH (United States). Dept. of Chemical Engineering

    2017-11-22

    Manganese-based metal oxide electrode materials are of great importance in electrochemical energy storage for their favorable redox behavior, low cost and environmental-friendliness. However, their storage capacity and cycle life in aqueous Na-ion electrolytes is not satisfactory. In this paper, we report the development of a bi-phase cobalt-manganese oxide (Co-Mn-O) nanostructured electrode material, comprised of a layered MnO2.H2O birnessite phase and a (Co0.83Mn0.13Va0.04)tetra(Co0.38Mn1.62)octaO3.72 (Va: vacancy; tetra: tetrahedral sites; octa: octahedral sites) spinel phase, verified by neutron total scattering and pair distribution function analyses. The bi-phase Co-Mn-O material demonstrates an excellent storage capacity towards Na-ions in an aqueous electrolyte (121 mA h g-1 at a scan rate of 1 mV s-1 in the half-cell and 81 mA h g-1 at a current density of 2 A g-1 after 5000 cycles in full-cells), as well as high rate performance (57 mA h g-1 a rate of 360 C). Electro-kinetic analysis and in situ X-ray diffraction measurements further confirm that the synergistic interaction between the spinel and layered phases, as well as the vacancy of the tetrahedral sites of spinel phase, contribute to the improved capacity and rate performance of the Co-Mn-O material by facilitating both diffusion-limited redox and capacitive charge storage processes.

  16. X-ray emission reduction and photon dose lowering by energy loss of fast electrons induced by return current during the interaction of a short-pulse high-intensity laser on a metal solid target

    Science.gov (United States)

    Compant La Fontaine, A.

    2018-04-01

    During the interaction of a short-pulse high-intensity laser with the preplasma produced by the pulse's pedestal in front of a high-Z metal solid target, high-energy electrons are produced, which in turn create an X-ray source by interacting with the atoms of the converter target. The current brought by the hot electrons is almost completely neutralized by a return current j → driven by the background electrons of the conductive target, and the force exerted on the hot electrons by the electric field E → which induces Ohmic heating j → .E → , produced by the background electrons, reduces the energy of the hot electrons and thus lowers the X-ray emission and photon dose. This effect is analyzed here by means of a simple 1-D temperature model which contains the most significant terms of the relativistic Fokker-Planck equation with electron multiple scattering, and the energy equations of ions, hot, and cold electrons are then solved numerically. This Ohmic heating energy loss fraction τOh is introduced as a corrective term in an improved photon dose model. For instance, for a ps laser pulse with 10 μm spot size, the dose obtained with a tantalum target is reduced by less than about 10% to 40% by the Ohmic heating, depending upon the plasma scale length, target thickness, laser parameters, and in particular its spot size. The laser and plasma parameters may be optimized to limit the effect of Ohmic heating, for instance at a small plasma scale length or small laser spot size. Conversely, others regimes not suitable for dose production are identified. For instance, the resistive heating is enhanced in a foam target or at a long plasma scale length and high laser spot size and intensity, as the mean emission angle θ0 of the incident hot electron bunch given by the ponderomotive force is small; thus, the dose produced by a laser interacting in a gas jet may be inhibited under these circumstances. The resistive heating may also be maximized in order to reduce

  17. Modeling Biphasic Environmental Decay of Pathogens and Implications for Risk Analysis.

    Science.gov (United States)

    Brouwer, Andrew F; Eisenberg, Marisa C; Remais, Justin V; Collender, Philip A; Meza, Rafael; Eisenberg, Joseph N S

    2017-02-21

    As the appreciation for the importance of the environment in infectious disease transmission has grown, so too has interest in pathogen fate and transport. Fate has been traditionally described by simple exponential decay, but there is increasing recognition that some pathogens demonstrate a biphasic pattern of decay-fast followed by slow. While many have attributed this behavior to population heterogeneity, we demonstrate that biphasic dynamics can arise through a number of plausible mechanisms. We examine the identifiability of a general model encompassing three such mechanisms: population heterogeneity, hardening off, and the existence of viable-but-not-culturable states. Although the models are not fully identifiable from longitudinal sampling studies of pathogen concentrations, we use a differential algebra approach to determine identifiable parameter combinations. Through case studies using Cryptosporidium and Escherichia coli, we show that failure to consider biphasic pathogen dynamics can lead to substantial under- or overestimation of disease risks and pathogen concentrations, depending on the context. More reliable models for environmental hazards and human health risks are possible with an improved understanding of the conditions in which biphasic die-off is expected. Understanding the mechanisms of pathogen decay will ultimately enhance our control efforts to mitigate exposure to environmental contamination.

  18. Occurrence of amylose-lipid complexes in teff and maize starch biphasic pastes

    CSIR Research Space (South Africa)

    Wokadala, OC

    2012-09-01

    Full Text Available The occurrence of amylose–lipid complexes was determined in maize and teff starch biphasic pastes i.e. peak viscosity pastes at short and prolonged pasting times. Maize and teff starches were pasted for 11.5 and 130 min with or without added stearic...

  19. A functional biphasic biomaterial homing mesenchymal stem cells for in vivo cartilage regeneration.

    Science.gov (United States)

    Huang, Hongjie; Zhang, Xin; Hu, Xiaoqing; Shao, Zhenxing; Zhu, Jingxian; Dai, Linghui; Man, Zhentao; Yuan, Lan; Chen, Haifeng; Zhou, Chunyan; Ao, Yingfang

    2014-12-01

    Cartilage regeneration after trauma is still a great challenge for clinicians and researchers due to many reasons, such as joint load-bearing, synovial movement and the paucity of endogenous repair cells. To overcome these limitations, we constructed a functional biomaterial using a biphasic scaffold platform and a bone-derived mesenchymal stem cells (BMSCs)-specific affinity peptide. The biphasic scaffold platform retains more cells homogeneously within the sol-gel transition of chitosan and provides sufficient solid matrix strength. This biphasic scaffold platform is functionalized with an affinity peptide targeting a cell source of interest, BMSCs. The presence of conjugated peptide gives this system a biological functionality towards BMSC-specific homing both in vitro and in vivo. The functional biomaterial can stimulate stem cell proliferation and chondrogenic differentiation during in vitro culture. Six months after in vivo implantation, compared with routine surgery or control scaffolds, the functional biomaterials induced superior cartilage repair without complications, as indicated by histological observations, magnetic resonance imaging and biomechanical properties. Beyond cartilage repair, this functional biphasic scaffold may provide a biomaterial framework for one-step tissue engineering strategy by homing endogenous cells to stimulate tissue regeneration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Recycling nanoparticle catalysts without separation based on a pickering emulsion/organic biphasic system.

    Science.gov (United States)

    Liu, Huifang; Zhang, Zhiming; Yang, Hengquan; Cheng, Fangqin; Du, Zhiping

    2014-07-01

    A conceptually novel methodology is explored for in situ recycling of nanoparticle catalysts based on transforming a conventional organic/aqueous biphasic system into a Pickering emulsion/organic biphasic system (PEOBS). The suggested PEOBS exists as two phases, with the nanoparticle catalyst "anchored" in the Pickering emulsion phase, but is "continuous" between the organic phase and the continuous phase of the Pickering emulsion. Aqueous hydrogenations are used to evaluate the reaction performances of PEOBS, and the underlying principles of PEOBS are preliminarily elaborated. The unique properties of PEOBS lead to many intriguing findings, which are unlikely to be achieved in the reported biphasic systems. PEOBS exhibits more than a fourfold enhancement in catalysis efficiency in comparison with a conventional biphasic system. Impressively, PEOBS enables the organic product to be facilely isolated through simple decantation and the nanoparticle catalyst can be recycled in situ without the need for "separation". Its recycling effectiveness is justified by ten reaction cycles without significant catalyst loss. The simple protocol, in conjunction with the stability to simultaneously achieve high catalysis efficiency and excellent catalyst recyclability, makes PEOBS a promising methodology to develop more sustainable nanocatalysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Temperature dependence of microwave absorption phenomena in single and biphase soft magnetic microwires

    Czech Academy of Sciences Publication Activity Database

    El Kammouni, R.; Vázquez, M.; Lezama, L.; Kurlyandskaya, G.; Kraus, Luděk

    2014-01-01

    Roč. 368, Nov (2014), 126-132 ISSN 0304-8853 Institutional support: RVO:68378271 Keywords : magnetic microwire * ferromagnetic resonance * microwave absorption * biphase magnetic system Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.970, year: 2014

  2. Preparation of highly infective Leishmania promastigotes by cultivation on SNB-9 biphasic medium.

    Science.gov (United States)

    Grekov, Igor; Svobodová, Milena; Nohýnková, Eva; Lipoldová, Marie

    2011-12-01

    Protozoan hemoflagellates Leishmania are causative agents of leishmaniases and an important biological model for study of host-pathogen interaction. A wide range of methods of Leishmania cultivation on both biphasic and liquid media is available. Biphasic media are considered to be superior for initial isolation of the parasites and obtaining high promastigote infectivity; however, liquid media are more suitable for large-scale experiments. The aim of the present study was the adaptation and optimization of the cultivation of Leishmania promastigotes on a biphasic SNB-9 (saline-neopeptone-blood 9) medium that was originally developed for Trypanosoma cultivation and combines the advantages of biphasic and liquid media. SNB-9 medium is characterized with a large volume of the liquid phase, which facilitates the manipulation with the culture and provides parasite yields comparable to parasite yields on such liquid medium as Schneider's Insect Medium. We demonstrate that SNB-9 very considerably surpasses Schneider's Insect Medium in in vitro infectivity of the parasites. Additionally, we show that the ratio of apoptotic parasites, which are important for the infectivity of the inoculum, in Leishmania culture in SNB-9 is higher than in Leishmania culture in Schneider's Insect Medium. Thus, we demonstrate that the cultivation of Leishmania on SNB-9 reliably yields highly infective promastigotes suitable for experimental infection. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Coherent combining pulse bursts in time domain

    Science.gov (United States)

    Galvanauskas, Almantas

    2018-01-09

    A beam combining and pulse stacking technique is provided that enhances laser pulse energy by coherent stacking pulse bursts (i.e. non-periodic pulsed signals) in time domain. This energy enhancement is achieved by using various configurations of Fabry-Perot, Gires-Tournois and other types of resonant cavities, so that a multiple-pulse burst incident at either a single input or multiple inputs of the system produces an output with a solitary pulse, which contains the summed energy of the incident multiple pulses from all beams. This disclosure provides a substantial improvement over conventional coherent-combining methods in that it achieves very high pulse energies using a relatively small number of combined laser systems, thus providing with orders of magnitude reduction in system size, complexity, and cost compared to current combining approaches.

  4. Pulse radiolysis

    International Nuclear Information System (INIS)

    Greenshields, H.; Seddon, W.A.

    1982-03-01

    This supplement to two bibliographies published in 1970 and 1972 lists 734 references to the literature of pulse radiolysis, arranged under eight broad subject headings. The references were compiled by searching Biological Abstracts, Chemical Abstracts, Nuclear Science Abstracts and the Weekly List of Papers in Radiation Chemistry issued by the Radiation Chemistry Data Center of Notre Dame University. Full bibliographic data is given for papers published in the period 1971 to 1974. A personal author index listing more than 600 authors and a similar number of co-authors is included

  5. PULSE COLUMN

    Science.gov (United States)

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  6. Host-Guest Inclusion Complexes between Amlodipine Enantiomers in Biphasic Recognition Chiral Extraction System using Tartaric Acid and β-Cyclodextrin Derivatives as Positive Confirmation Using of their Enantioselective Extraction

    OpenAIRE

    AZZAM, Khaldun; ABDALLAH, Hassan; HALIM, Hairul; AHMAD, Maizatul; SHAIBAH, Hassan

    2015-01-01

    The current work reports an extended theoretical study from our previous experimental work for the enantioselective extraction of amlodipine enantiomers in a biphasic recognition chiral extraction system (BRCES) consisting of hydrophobic D-diisopropyl tartrate dissolved in organic phase (n-decanol) and hydrophilic hydroxypropyl-?-cyclodextrin (HP-?-CD) in aqueous phase (acetate buffer) which preferentially recognize the R-enantiomer and S-enantiomer, respectively. The calculations were simula...

  7. Pulse plating of nickel deposits

    Energy Technology Data Exchange (ETDEWEB)

    Stimetz, C.J.; Stevenson, M.F.

    1980-02-01

    Pulse plated and conventional nickel deposits have been compared for differences in morphology, mechanical properties, and microstructure. The deposits were obtained from nickel sulfamate, nickel chloride, and Watts nickel plating solutions. No significant differences were found in the direct and pulse current deposits from the sulfamate and chloride solutions; however, significant differences in microstructure, yield strength, and microhardness were observed in deposits from the Watts nickel solution.

  8. Pulse combustion: an assessment of opportunities for increased efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Brenchley, D.L.; Bomelburg, H.J.

    1984-12-01

    The results of a literature review on pulse combustion are discussed. Current, near-future, and potential opportunities for pulse combustion applications are summarized, and the barriers to developing and using pulse combustion technology are discussed, along with research and development needs. Also provided are the proceedings of a pulse combustion workshop held in May, 1984 in Seattle, Washington. (LEW)

  9. Lowering of sensory, motor, and pain-tolerance thresholds with burst duration using kilohertz-frequency alternating current electric stimulation.

    Science.gov (United States)

    Ward, Alex R; Lucas-Toumbourou, Stacey

    2007-08-01

    To determine the optimum burst duration for discrimination between sensory, motor, and pain-tolerance thresholds using 50-Hz bursts of kilohertz-frequency sinusoidal alternating current (AC) applied transcutaneously to human subjects. A repeated-measures randomized controlled trial. A research laboratory. Twenty-six healthy young adults. Bursts of AC electric stimulation at frequencies of 1 and 4kHz. Burst durations ranged from 250micros (for 1 cycle of 4kHz AC, ie, a single biphasic pulse) to 20ms (continuous AC). We measured sensory, motor, and pain-tolerance thresholds at frequencies of 1 and 4kHz. We found that threshold voltages decreased to a minimum with increasing burst duration. The minimum threshold identified the "utilization time" over which summation of subthreshold stimuli occurs. Above the utilization time, thresholds increased. Estimated utilization times differed for sensory ( approximately 7ms), motor (>10ms), and pain-tolerance (>or=20ms). As a consequence, relative thresholds varied with burst duration. A maximum separation between sensory, motor, and pain-tolerance thresholds was found to occur with bursts in the range 1 to 4ms. Short-duration kilohertz-frequency AC bursts might have a more useful role in rehabilitation than either pulsed current or the long duration bursts that characterize Russian and interferential currents. Further clinical studies are needed.

  10. Influence of pulse electrodeposition parameters on microhardness ...

    Indian Academy of Sciences (India)

    and fine globular. Also, effect of electrodeposition parameters such as average current density, pulse frequency and duty cycle on the microhardness and grain size of nanocomposite coatings that produced through the pulse current electrodeposition method have been investigated. By amplifying both duty cycles up to 50% ...

  11. Psychophysical recovery from pulse-train forward masking in electric hearing

    Science.gov (United States)

    Nelson, David A.; Donaldson, Gail S.

    2002-12-01

    Psychophysical pulse-train forward-masking (PTFM) recovery functions were measured in fifteen subjects with the Nucleus mini-22 cochlear implant and six subjects with the Clarion cochlear implant. Masker and probe stimuli were 500-Hz trains of 200- or 77-μs/phase biphasic current pulses. Electrode configurations were bipolar for Nucleus subjects and monopolar for Clarion subjects. Masker duration was 320 ms. Probe duration was either 10 ms or 30 ms. Recovery functions were measured for a high-level masker on a middle electrode in all 21 subjects, on apical and basal electrodes in 7 of the Nucleus and 3 of the Clarion subjects, and for multiple masker levels on the middle electrode in 8 Nucleus subjects and 6 Clarion subjects. Recovery functions were described by an exponential process in which threshold shift (in μA) decreased exponentially with increasing time delay between the offset of the masker pulse train and the offset of the probe pulse train. All but 3 of the 21 subjects demonstrated recovery time constants on a middle electrode that were less than 95 ms. The mean time constant for these 18 subjects was 54 ms (s.d. 17 ms). Three other subjects tested on three electrodes exhibited time constants larger than 95 ms from an apical electrode only. Growth-of-masking slopes depended upon time delay, as expected from an exponential recovery process, i.e., progressively shallower slopes were observed at time delays of 10 ms and 50 ms. Recovery of threshold shift (in μA) for PTFM in electrical hearing behaves in the same way as recovery of threshold shift (in dB) for pure-tone forward masking in acoustic hearing. This supports the concept that linear microamps are the electrical equivalent of acoustic decibels. Recovery from PTFM was not related to speech recognition in a simple manner. Three subjects with prolonged PTFM recovery demonstrated poor speech scores. The remaining subjects with apparently normal PTFM recovery demonstrated speech scores ranging from

  12. Square pulse linear transformer driver

    Science.gov (United States)

    Kim, A. A.; Mazarakis, M. G.; Sinebryukhov, V. A.; Volkov, S. N.; Kondratiev, S. S.; Alexeenko, V. M.; Bayol, F.; Demol, G.; Stygar, W. A.

    2012-04-01

    The linear transformer driver (LTD) technological approach can result in relatively compact devices that can deliver fast, high current, and high-voltage pulses straight out of the LTD cavity without any complicated pulse forming and pulse compression network. Through multistage inductively insulated voltage adders, the output pulse, increased in voltage amplitude, can be applied directly to the load. The usual LTD architecture [A. A. Kim, M. G. Mazarakis, V. A. Sinebryukhov, B. M. Kovalchuk, V. A. Vizir, S. N Volkov, F. Bayol, A. N. Bastrikov, V. G. Durakov, S. V. Frolov, V. M. Alexeenko, D. H. McDaniel, W. E. Fowler, K. LeCheen, C. Olson, W. A. Stygar, K. W. Struve, J. Porter, and R. M. Gilgenbach, Phys. Rev. ST Accel. Beams 12, 050402 (2009)PRABFM1098-440210.1103/PhysRevSTAB.12.050402; M. G. Mazarakis, W. E. Fowler, A. A. Kim, V. A. Sinebryukhov, S. T. Rogowski, R. A. Sharpe, D. H. McDaniel, C. L. Olson, J. L. Porter, K. W. Struve, W. A. Stygar, and J. R. Woodworth, Phys. Rev. ST Accel. Beams 12, 050401 (2009)PRABFM1098-440210.1103/PhysRevSTAB.12.050401] provides sine shaped output pulses that may not be well suited for some applications like z-pinch drivers, flash radiography, high power microwaves, etc. A more suitable power pulse would have a flat or trapezoidal (rising or falling) top. In this paper, we present the design and first test results of an LTD cavity that generates such a type of output pulse by including within its circular array a number of third harmonic bricks in addition to the main bricks. A voltage adder made out of a square pulse cavity linear array will produce the same shape output pulses provided that the timing of each cavity is synchronized with the propagation of the electromagnetic pulse.

  13. Rapid glucocorticoid-induced activation of TRP and CB1 receptors causes biphasic modulation of glutamate release in gastric-related hypothalamic preautonomic neurons

    Directory of Open Access Journals (Sweden)

    Carie R. Boychuk

    2013-01-01

    Full Text Available Glucocorticoids rapidly regulate synaptic input to neuroendocrine cells in the hypothalamic paraventricular nucleus (PVN by inducing the retrograde release of endogenous messengers. Here we investigated the rapid effects of dexamethasone (DEX on excitatory synaptic input to feeding-related, preautonomic PVN neurons using whole-cell patch-clamp recordings. In ~50% of identified gastric-related preautonomic PVN neurons, DEX elicited a biphasic synaptic response characterized by an initial rapid and transient increase in the frequency of miniature excitatory postsynaptic currents (mEPSCs, followed by a decrease in mEPSC frequency within 9 min; remaining cells displayed only a decrease in mEPSC frequency. The late-phase decrease in mEPSC frequency was mimicked by the cannabinoid receptor agonists anandamide and WIN 55,212-2, and it was blocked by the CB1 receptor antagonist AM251. The biphasic DEX effect was mimicked by anandamide (AEA. The early increase in mEPSCs was mimicked by activation of transient receptor potential vanilloid type 1 (TRPV1 receptors with capsaicin and by activation of TRPV4 receptors with 4-α-PDD. The increase was reduced, but not blocked, by selective TRPV1 antagonists and in TRPV1-knockout mice; it was blocked completely by the broad-spectrum TRPV antagonist ruthenium red and by combined application of selective TRPV1 and TRPV4 antagonists. The DEX effects were prevented entirely by intracellular infusion of the G-protein inhibitor, GDPβS. Thus, DEX biphasically modulates synaptic glutamate onto a subset of gastric-related PVN neurons, which is likely mediated by induction of a retrograde messenger. The effect includes a TRPV1/4 receptor-mediated transient increase and subsequent CB1 receptor-mediated suppression of glutamate release. Multiphasic modulation of glutamate input to PVN neurons represents a previously unappreciated complexity of control of autonomic output by glucocorticoids and eCBs.

  14. Pulsed magnetic field-electron cyclotron resonance ion source operation

    International Nuclear Information System (INIS)

    Muehle, C.; Ratzinger, U.; Joest, G.; Leible, K.; Schennach, S.; Wolf, B.H.

    1996-01-01

    The pulsed magnetic field (PuMa)-electron cyclotron resonance (ECR) ion source uses a pulsed coil to improve the peak current by opening the magnetic bottle along the beam axis. After demonstration of the principle of the pulsed magnetic extraction, the ion source was tested with different gases. We received promising results from helium to krypton. The influence of the current in the pulsed coil on the analyzed ion current was measured. With increased current levels within the pulsed coil not only the pulse height of the PuMa pulse, but the pulse length can also be controlled. By using the pulsed coil the maximum of the charge state distribution can be shifted to higher charge states. copyright 1996 American Institute of Physics

  15. Biphasic versus monophasic waveforms for transthoracic defibrillation in out-of-hospital cardiac arrest.

    Science.gov (United States)

    Faddy, Steven C; Jennings, Paul A

    2016-02-10

    Transthoracic defibrillation is a potentially life-saving treatment for people with ventricular fibrillation (VF) and haemodynamically unstable ventricular tachycardia (VT). In recent years, biphasic waveforms have become more commonly used for defibrillation than monophasic waveforms. Clinical trials of internal defibrillation and transthoracic defibrillation of short-duration arrhythmias of up to 30 seconds have demonstrated the superiority of biphasic waveforms over monophasic waveforms. However, out-of-hospital cardiac arrest (OHCA) involves a duration of VF/VT of several minutes before defibrillation is attempted. To determine the efficacy and safety of biphasic defibrillation waveforms, compared to monophasic, for resuscitation of people experiencing out-of-hospital cardiac arrest. We searched the following electronic databases for potentially relevant studies up to 10 September 2014: the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE and EMBASE. Also we checked the bibliographies of relevant studies and review articles, contacted authors of published reviews and reviewed webpages (including those of device manufacturers) relevant to the review topic. We handsearched the abstracts of conference proceedings for the American Heart Association, American College of Cardiology, European Society of Cardiology, European Resuscitation Council, Society of Critical Care Medicine and European Society of Intensive Care Medicine. Regarding language restrictions, we did not apply any. We included randomised controlled trials (RCTs) that compared biphasic and monophasic waveform defibrillation in adults with OHCA. Two review authors independently screened the literature search results. Two review authors independently extracted data from the included trials and performed 'Risk of bias' assessments. We resolved any disagreements by discussion and consensus. The primary outcome was the risk of failure to achieve return of spontaneous circulation (ROSC

  16. A Study of New Pulse Auscultation System

    Directory of Open Access Journals (Sweden)

    Ying-Yun Chen

    2015-04-01

    Full Text Available This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine’s pulsing techniques, where pulse signals at places called “cun”, “guan” and “chi” of the left hand were measured during lifting (100 g, searching (125 g and pressing (150 g actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners’ objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision.

  17. A study of new pulse auscultation system.

    Science.gov (United States)

    Chen, Ying-Yun; Chang, Rong-Seng

    2015-04-14

    This study presents a new type of pulse auscultation system, which uses a condenser microphone to measure pulse sound waves on the wrist, captures the microphone signal for filtering, amplifies the useful signal and outputs it to an oscilloscope in analog form for waveform display and storage and delivers it to a computer to perform a Fast Fourier Transform (FFT) and convert the pulse sound waveform into a heartbeat frequency. Furthermore, it also uses an audio signal amplifier to deliver the pulse sound by speaker. The study observed the principles of Traditional Chinese Medicine's pulsing techniques, where pulse signals at places called "cun", "guan" and "chi" of the left hand were measured during lifting (100 g), searching (125 g) and pressing (150 g) actions. Because the system collects the vibration sound caused by the pulse, the sensor itself is not affected by the applied pressure, unlike current pulse piezoelectric sensing instruments, therefore, under any kind of pulsing pressure, it displays pulse changes and waveforms with the same accuracy. We provide an acquired pulse and waveform signal suitable for Chinese Medicine practitioners' objective pulse diagnosis, thus providing a scientific basis for this Traditional Chinese Medicine practice. This study also presents a novel circuit design using an active filtering method. An operational amplifier with its differential features eliminates the interference from external signals, including the instant high-frequency noise. In addition, the system has the advantages of simple circuitry, cheap cost and high precision.

  18. Bi-phasic growth of Listeria monocytogenes in chemically defined medium at low temperatures.

    Science.gov (United States)

    Tyrovouzis, Nikolaos A; Angelidis, Apostolos S; Stoforos, Nikolaos G

    2014-09-01

    The present work reports a novel observation regarding the growth of L. monocytogenes in modified Welshimer's broth (MWB) at low temperatures. Specifically, the direct monitoring of the growth of L. monocytogenes Scott A using plate count data revealed that the pathogen displays a bi-phasic growth pattern in MWB at 7 °C. This bi-phasic growth pattern is masked (not observed) when optical density (OD) measurements are used to monitor growth due to the inability of OD readings to detect L. monocytogenes population density increases up to 10(7) CFU/mL. This bi-phasic growth phenomenon was further investigated as a function of growth temperature (4 °C, 7 °C, 10 °C, 14 °C and 18 °C), medium composition (by altering the MWB composition by ten-fold increases in different sets of medium constituents), inoculum level (10(2), 10(3), 10(4), 10(5), 10(6), and 10(7) CFU/mL) and L. monocytogenes strain (10 strains). The growth of L. monocytogenes Scott A in MWB at 7 °C, 10 °C and 14 °C was consistently bi-phasic and independent of growth rate; at 18 °C, growth was consistently mono-phasic (single-phase, typical sigmoid growth curves), whereas no growth was observed at 4 °C. The tested modifications in the composition of MWB did not influence the bi-phasic nature of L. monocytogenes Scott A growth at 7 °C, and, overall, we could not point out any strain-, or serotype-specific effects. On the other hand, the initial inoculum level appears to affect the form of the growth curve, as there was a shift towards mono-phasic growth in trials with increasing initial inocula. A mathematical model, based on a stepwise response and described through two sequential sigmoid curves, was used to describe bi-phasic growth and estimate the kinetic parameters of L. monocytogenes growth. An alternative hypothesis, based on the assumption of the existence of two subpopulations, possessing different growth kinetics, materialized under the stress imposed on L. monocytogenes cells due to the

  19. Ionic-Liquid-Based Acidic Aqueous Biphasic Systems for Simultaneous Leaching and Extraction of Metallic Ions.

    Science.gov (United States)

    Gras, Matthieu; Papaiconomou, Nicolas; Schaeffer, Nicolas; Chainet, Eric; Tedjar, Farouk; Coutinho, Joao A P; Billard, Isabelle

    2018-02-05

    The first instance of an acidic aqueous biphasic system (AcABS) based on tributyltetradecyl phosphonium chloride ([P 44414 ][Cl]) and an acid is here reported. This AcABS exhibits pronounced thermomorphic behavior and is shown to be applicable to the extraction of metal ions from concentrated acidic solutions. Metal ions such as cobalt(II), iron(III), platinum(IV) and nickel(II) are found to partition preferentially to one of the phases of the acidic aqueous biphasic system and it is here shown that it successfully allows the difficult separation of Co II from Ni II , here studied at 24 and 50 °C. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. A method for separating water soluble organics from a process stream by aqueous biphasic extraction

    Energy Technology Data Exchange (ETDEWEB)

    Chaiko, David J.; Mego, William A.

    1997-12-01

    The present invention relates to a method for separating water-miscible organic species from a process stream by aqueous biphasic extraction. In particular, the method includes extracting the organic species into a polymer-rich phase of an aqueous biphase system in which the process stream comprises the salt-rich phase, and, next, separating the polymer from the extracted organic species by contacting the loaded, polymer-rich phase with a water-immiscible organic phase. Alternatively, the polymer can be separated from the extracted organic species by raising the temperature of the loaded, polymer-rich phase above the cloud point, such that the polymer and the water-soluble organic species separate into two distinct aqueous phases. In either case, a substantially salt-free, concentrated aqueous solution containing the organic species is recovered.

  1. Biphasic catalysis using amphiphilic polyphenols-chelated noble metals as highly active and selective catalysts

    Science.gov (United States)

    Mao, Hui; Yu, Hong; Chen, Jing; Liao, Xuepin

    2013-01-01

    In the field of catalysis, it is highly desired to develop novel catalysts that combine the advantages of both homogeneous and heterogeneous catalysts. Here we disclose that the use of plant pholyphenol as amphiphilic large molecule ligand/stabilizer allows for the preparation of noble metal complex and noble metal nanoparticle catalysts. These catalysts are found to be highly selective and active in aqueous-organic biphasic catalysis of cinnamaldehyde and quinoline, and can be reused at least 3 times without significant loss of activity. Moreover, the catalytic activity and reusability of the catalysts can be rationally controlled by simply adjusting the content of polyphenols in the catalysts. Our strategy may be extended to design a wide range of aqueous-organic biphasic catalysis system. PMID:23863916

  2. Pseudo-biphasic extraction and liquid membrane transport of ionic solutes using micelle-based processes

    International Nuclear Information System (INIS)

    Tondre, Ch.

    1995-01-01

    Different aspects between micellar extraction and solvent extraction were discussed. One way of using micellar systems to perform metal ion extraction consists in solubilizing lipophilic complexing agents in the hydrophobic core of the micelles, similarly to their solubilization in the organic phase in classical biphasic extraction. Metal ions dissolved in the continuous phase will be complexed or not, depending on their affinity for the micelle-solubilized extractant, the microscopic micelle/water interface playing a part analogous to the macroscopic organic/water interface in biphasic extraction. The yields of extraction (after ultrafiltration of the micellar pseudo-phase) when parameters such as the extractant/metal ratio or the extractant hydrophobicity are changed, show similar trends as those reported in the case of solvent extraction, but only diluted solutions can be treated that way. 14 refs

  3. Biphasic catalysis using amphiphilic polyphenols-chelated noble metals as highly active and selective catalysts.

    Science.gov (United States)

    Mao, Hui; Yu, Hong; Chen, Jing; Liao, Xuepin

    2013-01-01

    In the field of catalysis, it is highly desired to develop novel catalysts that combine the advantages of both homogeneous and heterogeneous catalysts. Here we disclose that the use of plant polyphenol as amphiphilic large molecule ligand/stabilizer allows for the preparation of noble metal complex and noble metal nanoparticle catalysts. These catalysts are found to be highly selective and active in aqueous-organic biphasic catalysis of cinnamaldehyde and quinoline, and can be reused at least 3 times without significant loss of activity. Moreover, the catalytic activity and reusability of the catalysts can be rationally controlled by simply adjusting the content of polyphenols in the catalysts. Our strategy may be extended to design a wide range of aqueous-organic biphasic catalysis system.

  4. Validation of a heterogeneous elastic-biphasic model for the numerical simulation of the PDL.

    Science.gov (United States)

    Favino, Marco; Gross, Christian; Drolshagen, Marcel; Keilig, Ludger; Deschner, James; Bourauel, Christoph; Krause, Rolf

    2013-01-01

    An elastic-biphasic model for the simulation of the periodontal ligament (PDL) and the adjacent tooth is presented and investigated. The PDL is modelled as a biphasic material following the work of Ehlers and Markert (2001 ), whereas the tooth is modelled as a linear elastic body. A spatial discretisation scheme is proposed based on mixed finite elements for the spatial discretisation. Due to nonlinearity in the model, a predictor-corrector scheme is employed as a temporal discretisation scheme. In order to validate the PDL model, in vitro measurements are compared with numerical simulations. The numerical simulations are performed using geometries resulting from micro-CT scanner of the same porcine tooth, which was employed for the in vitro measurements.

  5. Biphasic and boundary lubrication mechanisms in artificial hydrogel cartilage: A review.

    Science.gov (United States)

    Murakami, Teruo; Yarimitsu, Seido; Nakashima, Kazuhiro; Sakai, Nobuo; Yamaguchi, Tetsuo; Sawae, Yoshinori; Suzuki, Atsushi

    2015-12-01

    Various studies on the application of artificial hydrogel cartilage to cartilage substitutes and artificial joints have been conducted. It is expected in clinical application of artificial hydrogel cartilage that not only soft-elastohydrodynamic lubrication but biphasic, hydration, gel-film and boundary lubrication mechanisms will be effective to sustain extremely low friction and minimal wear in daily activities similar to healthy natural synovial joints with adaptive multimode lubrication. In this review article, the effectiveness of biphasic lubrication and boundary lubrication in hydrogels in thin film condition is focused in relation to the structures and properties of hydrogels. As examples, the tribological behaviors in three kinds of poly(vinyl alcohol) hydrogels with high water content are compared, and the importance of lubrication mechanism in biomimetic artificial hydrogel cartilage is discussed to extend the durability of cartilage substitute. © IMechE 2015.

  6. Efficacy and safety of biphasic insulin aspart and biphasic insulin lispro mix in patients with type 2 diabetes: A review of the literature

    Directory of Open Access Journals (Sweden)

    Ajay Kumar

    2016-01-01

    Full Text Available Type 2 diabetes (T2D represents an escalating burden worldwide, particularly in China and India. Compared with Caucasians, Asian people with diabetes have lower body mass index, increased visceral adiposity, and postprandial glucose (PPG/insulin resistance. Since postprandial hyperglycemia contributes significantly to total glycemic burden and is associated with heightened cardiovascular risk, targeting PPG early in T2D is paramount. Premixed insulin regimens are widely used in Asia due to their convenience and effectiveness. Data from randomized controlled trials and observational studies comparing efficacy and safety of biphasic insulin aspart 30 (BIAsp 30 with biphasic insulin lispro mix (LM 25/50 and versus other insulin therapies or oral antidiabetic drugs (OADs in T2D demonstrated that BIAsp 30 and LM 25/50 were associated with similar or greater improvements in glycemic control versus comparator regimens, such as basal–bolus insulin, in insulin-naÏve, and prior insulin users. Studies directly comparing BIAsp 30 and LM 25 provided conflicting glycemic control results. Safety data generally showed increased hypoglycemia and weight gain with premixed insulins versus basal–bolus insulin or OADs. However, large observational trials documented improvements in glycated hemoglobin, PPG, and hypoglycemia with BIAsp 30 in multi-ethnic patient populations. In summary, this literature review demonstrates that premixed insulin regimens are an appropriate and effective treatment choice in T2D.

  7. A hybrid composite system of biphasic calcium phosphate granules loaded with hyaluronic acid-gelatin hydrogel for bone regeneration.

    Science.gov (United States)

    Faruq, Omar; Kim, Boram; Padalhin, Andrew R; Lee, Gun Hee; Lee, Byong-Taek

    2017-10-01

    An ideal bone substitute should be made of biocompatible materials that mimic the structure, characteristics, and functions of natural bone. Many researchers have worked on the fabrication of different bone scaffold systems including ceramic-polymer hybrid system. In the present study, we incorporated hyaluronic acid-gelatin hydrogel to micro-channeled biphasic calcium phosphate granules as a carrier to improve cell attachment and proliferation through highly interconnected porous structure. This hybrid system is composed of ceramic biphasic calcium phosphate granules measuring 1 mm in diameter with seven holes and hyaluronic acid-gelatin hydrogel. This combination of biphasic calcium phosphate and hyaluronic acid-gelatin retained suitable characteristics for bone regeneration. The resulting scaffold had a porosity of 56% with a suitable pore sizes. The mechanical strength of biphasic calcium phosphate granule increased after loading hyaluronic acid-gelatin from 4.26 ± 0.43 to 6.57 ± 0.25 MPa, which is highly recommended for cancellous bone substitution. Swelling and degradation rates decreased in the hybrid scaffold compared to hydrogel due to the presence of granules in hybrid scaffold. In vitro cytocompatibility studies were observed by preosteoblasts (MC3T3-E1) cell line and the result revealed that biphasic calcium phosphate/hyaluronic acid-gelatin significantly increased cell growth and proliferation compared to biphasic calcium phosphate granules. Analysis of micro-computed tomography data and stained tissue sections from the implanted samples showed that the hybrid scaffold had good osseointegration and better bone formation in the scaffold one and two months postimplantation. Histological section confirmed the formation of dense collagenous tissue and new bone in biphasic calcium phosphate/hyaluronic acid-gelatin scaffolds at two months. Our study demonstrated that such hybrid biphasic calcium phosphate/hyaluronic acid-gelatin scaffold is a

  8. Pulse electric current sintering of cubic boron nitride/tungsten carbide–cobalt (cBN/WC–Co) composites: Effect of cBN particle size and volume fraction on their microstructure and properties

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Bo, E-mail: xiaoboking@gmail.com [State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xianning West Road No. 28, Xi' an 710049, Shaanxi Province (China); State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace Engineering, Xi' an Jiaotong University, Xianning West Road No. 28, Xi' an 710049, Shaanxi Province (China); Qin, Yi [State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xianning West Road No. 28, Xi' an 710049, Shaanxi Province (China); Jin, Feng [State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace Engineering, Xi' an Jiaotong University, Xianning West Road No. 28, Xi' an 710049, Shaanxi Province (China); Yang, Jian-Feng, E-mail: yang155@mail.xjtu.edu.cn [State Key Laboratory for Mechanical Behavior of Materials, Xi' an Jiaotong University, Xianning West Road No. 28, Xi' an 710049, Shaanxi Province (China); Ishizaki, Kozo [Department of Mechanical Engineering, Nagaoka University of Technology, Nagaoka 940-2188 (Japan)

    2014-06-01

    Cubic boron nitride/tungsten carbide–cobalt (cBN/WC–Co) composites were fabricated by pulse electric current sintering (PECS), using Ni–P as sintering additives to promote low temperature densification. The effect of cBN particle size and volume fraction on the densification, microstructure and mechanical properties of WC–Co composites was investigated. There was no phase transformation from cBN to hBN (hexagonal BN) with low-hardness due to low sintering temperature (1100–1200 °C) and short sintering time. Smaller cBN particle led to lower sinter-ability of the composites due to its high specific surface area. The 30 vol% 10–14 µm cBN/WC–Co composite (P14V30) exhibited high hardness (18.3 GPa, 1200 °C) and high fracture toughness (15.6 MP·m{sup 1/2}, 1000 °C). The high hardness resulted from the homogeneously dispersed cBN particles, which had a good bonding with the WC matrix. Increased fracture toughness was mainly attributed to crack deflection or bridging and pullout of cBN grains.

  9. Preparation of highly infective Leishmania promastigotes by cultivation on SNB-9 biphasic medium

    Czech Academy of Sciences Publication Activity Database

    Grekov, Igor; Svobodová, M.; Nohýnková, E.; Lipoldová, Marie

    2011-01-01

    Roč. 87, č. 3 (2011), s. 273-277 ISSN 0167-7012 R&D Projects: GA MŠk(CZ) LC06009; GA ČR GA310/08/1697 Institutional research plan: CEZ:AV0Z50520514 Keywords : Leishmania * SNB-9 * biphasic culture medium * parasite infectivity Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.086, year: 2011

  10. Nitric oxide interacts with salicylate to regulate biphasic ethylene production during the hypersensitive response.

    Science.gov (United States)

    Mur, Luis A J; Laarhoven, Lucas J J; Harren, Frans J M; Hall, Michael A; Smith, Aileen R

    2008-11-01

    C(2)H(4) is associated with plant defense, but its role during the hypersensitive response (HR) remains largely uncharacterized. C(2)H(4) production in tobacco (Nicotiana tabacum) following inoculation with HR-eliciting Pseudomonas syringae pathovars measured by laser photoacoustic detection was biphasic. A first transient rise (C(2)H(4)-I) occurred 1 to 4 h following inoculation with HR-eliciting, disease-forming, and nonpathogenic strains and also with flagellin (flg22). A second (avirulence-dependent) rise, at approximately 6 h (C(2)H(4)-II), was only seen with HR-eliciting strains. Tobacco leaves treated with the C(2)H(4) biosynthesis inhibitor, aminoethoxyvinylglycine, suggested that C(2)H(4) influenced the kinetics of a HR. Challenging salicylate hydroxylase-expressing tobacco lines and tissues exhibiting systemic acquired resistance suggested that C(2)H(4) production was influenced by salicylic acid (SA). Disrupted expression of a C(2)H(4) biosynthesis gene in salicylate hydroxylase tobacco plants implicated transcriptional control as a mechanism through which SA regulates C(2)H(4) production. Treating leaves to increase oxidative stress or injecting with SA initiated monophasic C(2)H(4) generation, but the nitric oxide (NO) donor sodium nitroprusside initiated biphasic rises. To test whether NO influenced biphasic C(2)H(4) production during the HR, the NO synthase inhibitor N(G)-nitro-L-arginine methyl ester was coinoculated with the avirulent strain of P. syringae pv phaseolicola into tobacco leaves. The first transient C(2)H(4) rise appeared to be unaffected by N(G)-nitro-L-arginine methyl ester, but the second rise was reduced. These data suggest that NO and SA are required to generate the biphasic pattern of C(2)H(4) production during the HR and may influence the kinetics of HR formation.

  11. Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn

    OpenAIRE

    S. N. Koval; A. Ye. Kulagin

    2006-01-01

    Biphasic positive airway pressure (BIPAP) (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP) is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency) is calculated ...

  12. Development of Modified-Release Tablets of Zolpidem Tartrate by Biphasic Quick/Slow Delivery System

    OpenAIRE

    Mahapatra, Anjan Kumar; Sameeraja, N. H.; Murthy, P. N.

    2014-01-01

    Zolpidem tartrate is a non-benzodiazepine analogue of imidazopyridine of sedative and hypnotic category. It has a short half-life with usual dosage regimen being 5 mg, two times a day, or 10 mg, once daily. The duration of action is considered too short in certain circumstances. Thus, it is desirable to lengthen the duration of action. The formulation design was implemented by preparing extended-release tablets of zolpidem tartrate using the biphasic delivery system technology, where sodium s...

  13. Influence of Biphasic Stimulation on Olfactory Ensheathing Cells for Neuroprosthetic Devices

    OpenAIRE

    Rachelle Therese Hassarati; Leslie John Foster; Rylie Adelle Green; Rylie Adelle Green

    2016-01-01

    The recent success of olfactory ensheathing cell (OEC) assisted regeneration of injured spinal cord has seen a rising interest in the use of these cells in tissue-engineered systems. Previously shown to support neural cell growth through glial scar tissue, OECs have the potential to assist neural network formation in living electrode systems to produce superior neuroprosthetic electrode surfaces. The following study sought to understand the influence of biphasic electrical stimulation (ES), i...

  14. Pulse pile-up. II: Tailed pulses

    International Nuclear Information System (INIS)

    Wilkinson, D.H.

    1990-07-01

    The considerations of the preceding paper are extended to the case of pulses having infinite (exponential) tails. Exact solutions are presented for pure exponential pulses all of the same height; ruin theory is applied for pulses of more realistic form. (Author) (2 refs., 9 figs.)

  15. WEC program for calculation of system of accelerating voltage pulses formation on lines with distributed parameters

    International Nuclear Information System (INIS)

    Gordeev, V.S.; Mikhailov, E.S.

    1999-01-01

    There were conducted calculations of one of operation modes of STRAUS-2 accelerator.Calculation diode current pulses were compared to current pulses measured experimentally. From the comparison it is clear that the difference of time-amplitude parameters of calculation pulse from those of experimental current pulse do not exceed 10%, what is within the accuracy of measurements

  16. Low-High and High-Low Biphasic Injection Forms in Computed Tomography Examinations of the Upper Abdomen

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Arana, E.; Tobarra, E.; Sierra, C.

    2006-01-01

    Purpose: To analyze the influence of different biphasic and monophasic injection rate protocols in abdominal computed tomography (CT). Material and Methods: A randomized, consecutive, parallel group study was designed and conducted in 60 patients studied with the same CT helical protocol. Patients were randomly distributed into three groups: (A) monophasic (120 ml at 2.5 ml/s); (B) low-high biphasic (120 ml, first 60 ml at a rate of 2 ml/s, the other 60 ml at 2.5 ml/s); and (C) high-low biphasic (120 ml, first 60 ml at a rate of 2.5 ml/s, the other 60 ml at 2 ml/s). All patients were injected with 300 mg I/ml non-ionic contrast media at a fixed delay time of 55 s. Contrast enhancement efficacy was evaluated by attenuation coefficient measurements. Results: Although non-significant, monophasic protocol enhancements were higher than biphasic protocol enhancements in all measurements except aortic bifurcation (p = 0.003). At this level, biphasic protocols obtained an increased mean enhancement from 7.6% to 2.5% compared to monophasic protocols. Conclusion: Monophasic contrast agent injection in helical CT of the upper abdomen produces a higher enhancement of parenchymal and venous structures. No significant difference was observed between low-high and high-low biphasic protocols

  17. Comparison of the lysis-centrifugation and agitated biphasic blood culture systems for detection of fungemia.

    Science.gov (United States)

    Murray, P R

    1991-01-01

    Although the detection of fungemia has been improved by the use of vented or biphasic blood culture bottles, the best recovery and earliest detection have been reported in the Isolator lysis-centrifugation system. It was recently demonstrated that improved detection of both bacteria and fungi was accomplished by mechanically agitating blood culture bottles for the first 24 h of incubation. In this study the detection of fungemia by use of the Isolator system was compared with that of an agitated biphasic system. A total of 182 fungi were isolated from blood specimens inoculated into both culture systems. No difference in the overall recovery of fungi or individual species of yeasts was observed between the two systems. However, all seven isolates of Histoplasma capsulatum were recovered in the Isolator system only. The time required to detect fungemia with each of the two systems was also compared. No statistically significant difference was observed. From the data collected during this 18-month study, it can be concluded that the overall recovery and time of detection of yeasts are equivalent in the lysis-centrifugation system and the agitated biphasic blood culture system. The lysis-centrifugation system is still superior for the detection of filamentous fungi such as H. capsulatum. PMID:1993772

  18. Synchronized oscillations of dimers in biphasic charged fd-virus suspensions.

    Science.gov (United States)

    Kang, K; Piao, S H; Choi, H J

    2016-08-01

    Micron-sized colloidal spheres that are dispersed in an isotropic-nematic biphasic host suspension of charged rods (fd-virus particles) are shown to spontaneously form dimers, which exhibit a synchronized oscillatory motion. Dimer formation is not observed in the monophase of isotropic and nematic suspensions. The synchronized oscillations of dimers are connected to the inhomogeneous state of the host suspension of charged rods (fd viruses) where nematic domains are in coexistence with isotropic regions. The synchronization of oscillations occurs in bulk states, in the absence of an external field. With a low field strength of an applied electric field, the synchronization is rather reduced, but it recovers again when the field is turned off. In this Rapid Communication, we report this observation as an example of the strange attractor, occurring in the mixture of PS (polystyrene) dimers in an isotropic-nematic coexistence biphasic fd-virus network. Furthermore, we highlight that the synchronization of PS-dimer oscillations is the result of a global bifurcation diagram, driven by a delicate balance between the short-attractive "twisted" interaction of PS dimers and long-ranged electrostatic repulsive interactions of charged fd rods. The interest is then in the local enhancement of "twist-nematic" elasticity in reorientation of the dimer oscillations. An analysis of image-time correlations is provided with the data movies and Fourier transforms of averaged orientations for the synchronized oscillations of dimers in the biphasic I-N coexistence concentration of charged fd-virus suspensions.

  19. Pre-earthquake Magnetic Pulses

    Science.gov (United States)

    Scoville, J.; Heraud, J. A.; Freund, F. T.

    2015-12-01

    A semiconductor model of rocks is shown to describe unipolar magnetic pulses, a phenomenon that has been observed prior to earthquakes. These pulses are suspected to be generated deep in the Earth's crust, in and around the hypocentral volume, days or even weeks before earth quakes. Their extremely long wavelength allows them to pass through kilometers of rock. Interestingly, when the sources of these pulses are triangulated, the locations coincide with the epicenters of future earthquakes. We couple a drift-diffusion semiconductor model to a magnetic field in order to describe the electromagnetic effects associated with electrical currents flowing within rocks. The resulting system of equations is solved numerically and it is seen that a volume of rock may act as a diode that produces transient currents when it switches bias. These unidirectional currents are expected to produce transient unipolar magnetic pulses similar in form, amplitude, and duration to those observed before earthquakes, and this suggests that the pulses could be the result of geophysical semiconductor processes.

  20. Optimal filter bandwidth for pulse oximetry

    Science.gov (United States)

    Stuban, Norbert; Niwayama, Masatsugu

    2012-10-01

    Pulse oximeters contain one or more signal filtering stages between the photodiode and microcontroller. These filters are responsible for removing the noise while retaining the useful frequency components of the signal, thus improving the signal-to-noise ratio. The corner frequencies of these filters affect not only the noise level, but also the shape of the pulse signal. Narrow filter bandwidth effectively suppresses the noise; however, at the same time, it distorts the useful signal components by decreasing the harmonic content. In this paper, we investigated the influence of the filter bandwidth on the accuracy of pulse oximeters. We used a pulse oximeter tester device to produce stable, repetitive pulse waves with digitally adjustable R ratio and heart rate. We built a pulse oximeter and attached it to the tester device. The pulse oximeter digitized the current of its photodiode directly, without any analog signal conditioning. We varied the corner frequency of the low-pass filter in the pulse oximeter in the range of 0.66-15 Hz by software. For the tester device, the R ratio was set to R = 1.00, and the R ratio deviation measured by the pulse oximeter was monitored as a function of the corner frequency of the low-pass filter. The results revealed that lowering the corner frequency of the low-pass filter did not decrease the accuracy of the oxygen level measurements. The lowest possible value of the corner frequency of the low-pass filter is the fundamental frequency of the pulse signal. We concluded that the harmonics of the pulse signal do not contribute to the accuracy of pulse oximetry. The results achieved by the pulse oximeter tester were verified by human experiments, performed on five healthy subjects. The results of the human measurements confirmed that filtering out the harmonics of the pulse signal does not degrade the accuracy of pulse oximetry.